-- **************************************************************************** -- :CPQ,DEV: -- -- * COMPAQ HOST OS RELATED INFORMATION SNMP MIB DEFINITIONS -- -- * $Date: 1999/10/06 19:44:45 $ -- * $Revision: 1.6 $ -- -- Compaq Computer Corporation -- Confidential - Need To Know -- **************************************************************************** -- :CPQ,ENDDEV: -- -- Host Operating System Information -- Management Information Base for SNMP Network Management -- -- -- Copyright 1999 Compaq Computer Corporation. -- All Rights Reserved. -- -- The information in this document is subject to change without notice. -- -- COMPAQ COMPUTER CORPORATION SHALL NOT BE LIABLE FOR TECHNICAL -- OR EDITORIAL ERRORS OR OMISSIONS CONATINED HEREIN; NOR FOR INCIDENTAL -- OR CONSEQUENTIAL DAMAGES RESULTING FROM THE FURNISHING, PERFORMANCE, -- OR USE OF THIS MATERIAL. -- -- Refer to the READMIB.RDM file for more information about the -- organization of the information in the Compaq Enterprise. -- -- The Host OS MIB provides operating system information, such as -- name, version, file system information, software running, and more. -- -- The Compaq Enterprise number is 232. -- The ASN.1 prefix to, and including the Compaq Enterprise is: -- 1.3.6.1.4.1.232 -- -- **************************************************************************** CPQHOST-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises FROM RFC1155-SMI Counter FROM RFC1155-SMI IpAddress FROM RFC1155-SMI DisplayString FROM RFC1213-MIB OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 sysName FROM RFC1213-MIB; compaq OBJECT IDENTIFIER ::= { enterprises 232 } cpqHostOs OBJECT IDENTIFIER ::= { compaq 11 } cpqHoMibRev OBJECT IDENTIFIER ::= { cpqHostOs 1 } cpqHoComponent OBJECT IDENTIFIER ::= { cpqHostOs 2 } cpqHoInterface OBJECT IDENTIFIER ::= { cpqHoComponent 1 } cpqHoInfo OBJECT IDENTIFIER ::= { cpqHoComponent 2 } cpqHoUtil OBJECT IDENTIFIER ::= { cpqHoComponent 3 } cpqHoFileSys OBJECT IDENTIFIER ::= { cpqHoComponent 4 } -- The cpqHoIfPhysMap group has been deprecated. cpqHoIfPhysMap OBJECT IDENTIFIER ::= { cpqHoComponent 5 } cpqHoSWRunning OBJECT IDENTIFIER ::= { cpqHoComponent 6 } cpqHoSwVer OBJECT IDENTIFIER ::= { cpqHoComponent 7 } cpqHoGeneric OBJECT IDENTIFIER ::= { cpqHoComponent 8 } cpqHoSwPerf OBJECT IDENTIFIER ::= { cpqHoComponent 9 } cpqHoSystemStatus OBJECT IDENTIFIER ::= { cpqHoComponent 10 } cpqHoTrapInfo OBJECT IDENTIFIER ::= { cpqHoComponent 11 } cpqHoClients OBJECT IDENTIFIER ::= { cpqHoComponent 12 } cpqHoMemory OBJECT IDENTIFIER ::= { cpqHoComponent 13 } cpqHoOsCommon OBJECT IDENTIFIER ::= { cpqHoInterface 4 } -- **************************************************************************** -- Host OS Information MIB Revision -- ================================ -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHostOs Group (1.3.6.1.4.1.232.11) -- cpqHoMibRev Group (1.3.6.1.4.1.232.11.1) -- -- Implementation of the cpqHoMibRev group is mandatory for all agents -- supporting the Compaq Host OS MIB. -- -- An Insight Agent conforming to this document will return a -- cpqHoMibRevMajor of one (1) and a cpqHoMibRevMinor of twelve (12). -- -- :CPQ,DEV: -- MIB Rev of 1.0 is for AUGUSTA time frame -- MIB Rev of 1.1 is for JIFFYLUBE time frame (3Q 1994) -- MIB Rev of 1.2 is for release 2.40 time frame (1Q 1995) -- MIB Rev of 1.3 is for release 2.60 time frame (2Q 1995) and indicates -- support for the following groups: -- cpqHoClient Group (1.3.6.1.4.1.232.11.2.12) -- cpqHoTrapInfo Group (1.3.6.1.4.1.232.11.2.11) -- cpqHoSystemStatus Group (1.3.6.1.4.1.232.11.2.10) -- MIB Rev of 1.4 is for release 3.00 time frame (1Q 1996) and includes -- support for Wiley. -- MIB Rev of 1.5 is for release 3.10(3.20) time frame (4Q 1996) and -- includes support for Hacksaw (multi-port nics). -- MIB Rev of 1.6 is for release 3.20 and indicates support for the -- integration server bit in the MIB status array. -- MIB Rev of 1.7 is for release 3.50 and indicates support for the -- cpqHoIfPhysMapCondition variable. -- MIB Rev of 1.8 is for release 3.70/4.01 and indicates support for the -- cpqHoWebMgmtPort variable and web mgmt available bit in the -- cpqHoMibStatusArray. -- MIB Rev of 1.9 is for release 4.20 and indicates support for the -- Process monitoring additions to the software running table and -- the cpqHoProcessEventTrap. -- Deprecated cpqHoIfPhysMap and the NIC status traps. -- MIB Rev of 1.10 is for release 4.23. Deprecates the -- cpqHoOsCommonModuleTable. -- MIB Rev of 1.11 is for release 4.30 and indicates support for the -- physical memory details. -- MIB Rev of 1.12 is for release 4.50 and indicates support for the -- new enumerations for the cpqHoOsType. -- :CPQ,ENDDEV: -- **************************************************************************** cpqHoMibRevMajor OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The Major Revision level of the MIB. A change in the major revision level represents a major change in the architecture of the MIB. A change in the major revision level may indicate a significant change in the information supported and/or the meaning of the supported information. Correct interpretation of data may require a MIB document with the same major revision level." ::= { cpqHoMibRev 1 } cpqHoMibRevMinor OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The Minor Revision level of the MIB. A change in the minor revision level may represent some minor additional support, no changes to any pre-existing information has occurred." ::= { cpqHoMibRev 2 } cpqHoMibCondition OBJECT-TYPE SYNTAX INTEGER { unknown(1), ok(2), -- default state degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The overall condition. This object represents the overall status of the server's host system represented by this MIB." -- :CPQ,DEV: -- cpqHoMibCondition = aggregate of all cpqHoIfPhysMapCondition's -- -- Before any additional conditions are bundled in here, you must -- understand how Insight is using this variable. -- :CPQ,ENDDEV: ::= { cpqHoMibRev 3 } -- **************************************************************************** -- Host OS Common -- ============== -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHostOs Group (1.3.6.1.4.1.232.11) -- cpqHoComponent Group (1.3.6.1.4.1.232.11.2) -- cpqHoInterface Group (1.3.6.1.4.1.232.11.2.1) -- cpqHoOsCommon Group (1.3.6.1.4.1.232.11.2.1.4) -- -- -- Implementation of the cpqHoOsCommon group is mandatory for all -- agents that support the Compaq Host OS MIB. -- -- **************************************************************************** cpqHoOsCommonPollFreq OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The Insight Agent's polling frequency. The frequency, in seconds, at which the Insight Agent requests information from the device driver. A frequency of zero (0) indicates that the Insight Agent retrieves the information upon request of a management station, it does not poll the device driver at a specific interval. If the poll frequency is zero (0) all attempts to write to this object will fail. If the poll frequency is non-zero, setting this value will change the polling frequency of the Insight Agent. Setting the poll frequency to zero (0) will always fail. An agent may choose to fail any request to change the poll frequency to a value that would severely impact system performance." ::= { cpqHoOsCommon 1 } -- **************************************************************************** -- Host OS Common Module Table -- =========================== -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHostOs Group (1.3.6.1.4.1.232.11) -- cpqHoComponent Group (1.3.6.1.4.1.232.11.2) -- cpqHoInterface Group (1.3.6.1.4.1.232.11.2.1) -- cpqHoOsCommon Group (1.3.6.1.4.1.232.11.2.1.4) -- cpqHoOsCommonModuleTable (1.3.6.1.4.1.232.11.2.1.4.2) deprecated -- -- **************************************************************************** cpqHoOsCommonModuleTable OBJECT-TYPE SYNTAX SEQUENCE OF CpqHoOsCommonModuleEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "A table of software modules that provide an interface to the device this MIB describes." ::= { cpqHoOsCommon 2 } cpqHoOsCommonModuleEntry OBJECT-TYPE SYNTAX CpqHoOsCommonModuleEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "A description of a software module that provides an interface to the device this MIB describes." INDEX { cpqHoOsCommonModuleIndex } ::= { cpqHoOsCommonModuleTable 1 } CpqHoOsCommonModuleEntry ::= SEQUENCE { cpqHoOsCommonModuleIndex INTEGER, cpqHoOsCommonModuleName DisplayString, cpqHoOsCommonModuleVersion DisplayString, cpqHoOsCommonModuleDate OCTET STRING, cpqHoOsCommonModulePurpose DisplayString } cpqHoOsCommonModuleIndex OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS deprecated DESCRIPTION "A unique index for this module description." ::= { cpqHoOsCommonModuleEntry 1 } cpqHoOsCommonModuleName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS deprecated DESCRIPTION "The module name." ::= { cpqHoOsCommonModuleEntry 2 } cpqHoOsCommonModuleVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (0..5)) ACCESS read-only STATUS deprecated DESCRIPTION "The module version in XX.YY format. Where XX is the major version number and YY is the minor version number. This field will be null (size 0) string if the agent cannot provide the module version." ::= { cpqHoOsCommonModuleEntry 3 } cpqHoOsCommonModuleDate OBJECT-TYPE SYNTAX OCTET STRING (SIZE (7)) ACCESS read-only STATUS deprecated DESCRIPTION "The module date. field octets contents range ===== ====== ======= ===== 1 1-2 year 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minute 0..59 6 7 second 0..60 (use 60 for leap-second) This field will be set to year = 0 if the agent cannot provide the module date. The hour, minute, and second field will be set to zero (0) if they are not relevant. The year field is set with the most significant octect first." ::= { cpqHoOsCommonModuleEntry 4 } cpqHoOsCommonModulePurpose OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS deprecated DESCRIPTION "The purpose of the module described in this entry." ::= { cpqHoOsCommonModuleEntry 5 } -- **************************************************************************** -- Host OS Information Group -- ========================= -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHostOs Group (1.3.6.1.4.1.232.11) -- cpqHoComponent Group (1.3.6.1.4.1.232.11.2) -- cpqHoInfo Group (1.3.6.1.4.1.232.11.2.2) -- -- -- The cpqHoInfo group describes some general information about the -- host OS. -- -- Implementation of the cpqHoInfo group is mandatory for all -- agents supporting the Compaq Host OS MIB. -- -- **************************************************************************** cpqHoName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The name of the host operating system (OS)." ::= { cpqHoInfo 1 } cpqHoVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The version of the host OS." ::= { cpqHoInfo 2 } cpqHoDesc OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "A further description of the host OS." ::= { cpqHoInfo 3 } cpqHoOsType OBJECT-TYPE SYNTAX INTEGER { other(1), netware(2), -- Novell NetWare windowsnt(3), -- Microsoft Windows NT sco-unix(4), -- SCO UNIX unixware(5), -- Novell UnixWare os-2(6), -- IBM OS/2 ms-dos(7), -- Microsoft DOS dos-windows(8), -- Microsoft DOS + Microsoft Windows windows95(9), -- Microsoft Windows 95 windows98(10), -- Microsoft Windows 98 open-vms(11), -- Open VMS nsk(12), -- Non Stop Kernel windowsCE(13), -- Microsoft Windows CE linux(14) -- Linux } ACCESS read-only STATUS mandatory DESCRIPTION "Host Operating system enumeration." -- :CPQ,DEV: -- Older versions of agents may return windows95 even though windows98 may -- be running. -- :CPQ,ENDDEV: ::= { cpqHoInfo 4 } cpqHoTelnet OBJECT-TYPE SYNTAX INTEGER { other(1), available(2), notavailable(3) -- default } ACCESS read-only STATUS mandatory DESCRIPTION "Telnet on socket 23 is available." -- -- This variable specifies the availability of telnet. Only socket 23 is -- checked for telnet services. -- ::= { cpqHoInfo 5 } -- **************************************************************************** -- Host OS CPU Utilization Table -- ============================= -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHostOs Group (1.3.6.1.4.1.232.11) -- cpqHoComponent Group (1.3.6.1.4.1.232.11.2) -- cpqHoUtil Group (1.3.6.1.4.1.232.11.2.3) -- cpqHoCpuUtilTable (1.3.6.1.4.1.232.11.2.3.1) -- -- -- The cpqHoUtil group contains measures of system utilization. -- -- Implementation of the cpqHoUtil group is mandatory for all agents -- that support the Compaq Host OS MIB. -- -- **************************************************************************** -- :CPQ,DEV: -- The entries in the cpqHoCpuUtilTable must always directly correspond -- to the entries in the CPU table, cpqSeCpuTable, in the standard -- equipment MIB, CPQSTDEQ.MIB. For each entry in cpqSeCpuTable, -- there must be a corresponding entry in the cpqHoCpuUtilTable with -- the same index. If the utilization of a particular processor can -- not be determined, the value returned should be -1. -- -- :CPQ,ENDDEV: cpqHoCpuUtilTable OBJECT-TYPE SYNTAX SEQUENCE OF CpqHoCpuUtilEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of CPU utilization entries." ::= { cpqHoUtil 1 } cpqHoCpuUtilEntry OBJECT-TYPE SYNTAX CpqHoCpuUtilEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A description of a CPU's utilization." INDEX { cpqHoCpuUtilUnitIndex } ::= { cpqHoCpuUtilTable 1 } CpqHoCpuUtilEntry ::= SEQUENCE { cpqHoCpuUtilUnitIndex INTEGER, cpqHoCpuUtilMin INTEGER, cpqHoCpuUtilFiveMin INTEGER, cpqHoCpuUtilThirtyMin INTEGER, cpqHoCpuUtilHour INTEGER } cpqHoCpuUtilUnitIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This number uniquely specifies a processor unit. A processing unit may be a set of processing chips that are on the same board or for other reasons work together as a unit. The main processor unit (if such a concept is valid for this machine) will always have the lowest (first) index." ::= { cpqHoCpuUtilEntry 1 } cpqHoCpuUtilMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The CPU utilization as a percentage of the theoretical maximum during the last minute. A value of -1 indicates that no CPU utilization information is available for this processor." ::= { cpqHoCpuUtilEntry 2 } cpqHoCpuUtilFiveMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The CPU utilization as a percentage of the theoretical maximum during the last five minutes. A value of -1 indicates that no CPU utilization information is available for this processor." ::= { cpqHoCpuUtilEntry 3 } cpqHoCpuUtilThirtyMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The CPU utilization as a percentage of the theoretical maximum during the last thirty minutes. A value of -1 indicates that no CPU utilization information is available for this processor." ::= { cpqHoCpuUtilEntry 4 } cpqHoCpuUtilHour OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The CPU utilization as a percentage of the theoretical maximum during the last hour. A value of -1 indicates that no CPU utilization information is available for this processor." ::= { cpqHoCpuUtilEntry 5 } -- **************************************************************************** -- Host OS File System Table -- ========================= -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHostOs Group (1.3.6.1.4.1.232.11) -- cpqHoComponent Group (1.3.6.1.4.1.232.11.2) -- cpqHoFileSys Group (1.3.6.1.4.1.232.11.2.4) -- cpqHoFileSysTable (1.3.6.1.4.1.232.11.2.4.1) -- -- The cpqHoFileSys group contains configuration and status information -- about the file system. -- -- **************************************************************************** cpqHoFileSysTable OBJECT-TYPE SYNTAX SEQUENCE OF CpqHoFileSysEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of file system descriptions." ::= { cpqHoFileSys 1 } cpqHoFileSysEntry OBJECT-TYPE SYNTAX CpqHoFileSysEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A file system description." INDEX { cpqHoFileSysIndex } ::= { cpqHoFileSysTable 1 } CpqHoFileSysEntry ::= SEQUENCE { cpqHoFileSysIndex INTEGER, cpqHoFileSysDesc DisplayString, cpqHoFileSysSpaceTotal INTEGER, cpqHoFileSysSpaceUsed INTEGER, cpqHoFileSysPercentSpaceUsed INTEGER, cpqHoFileSysAllocUnitsTotal INTEGER, cpqHoFileSysAllocUnitsUsed INTEGER } cpqHoFileSysIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "An index that uniquely specifies this entry." ::= { cpqHoFileSysEntry 1 } cpqHoFileSysDesc OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "A description of the file system." ::= { cpqHoFileSysEntry 2 } cpqHoFileSysSpaceTotal OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The file system size in megabytes. This item will be set to -1 if the agent is unable to determine this information." ::= { cpqHoFileSysEntry 3 } cpqHoFileSysSpaceUsed OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The megabytes of file system space currently in use. This item will be set to -1 if the agent is unable to determine this information." ::= { cpqHoFileSysEntry 4 } cpqHoFileSysPercentSpaceUsed OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The percent of file system space currently in use. This item will be set to -1 if this information is not available." -- :CPQ,DEV: -- This value should be equal to (FileSysSpaceUsed*100) / FileSysSpaceTotal. -- :CPQ,ENDDEV: ::= { cpqHoFileSysEntry 5 } cpqHoFileSysAllocUnitsTotal OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of files (directory entries) that can be stored on the file system if a limit exists other than total space used. This item will be set to -1 if no such limit exists." ::= { cpqHoFileSysEntry 6 } cpqHoFileSysAllocUnitsUsed OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of files (directory entries) on this file system. This item will be set to -1 if the agent does not determine this information." ::= { cpqHoFileSysEntry 7 } -- **************************************************************************** -- Host OS Interface Physical Map Table -- ==================================== -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHostOs Group (1.3.6.1.4.1.232.11) -- cpqHoComponent Group (1.3.6.1.4.1.232.11.2) -- cpqHoIfPhysMap Group (1.3.6.1.4.1.232.11.2.5) deprecated -- cpqHoIfPhysMapTable (1.3.6.1.4.1.232.11.2.5.1) deprecated -- -- -- The cpqHoIfPhysMap group contains information to map interface numbers -- in the MIB-II interface group to the physical interface cards that -- implement the interface. -- -- Implementation of the cpqHoIfPhysMap group is mandatory for all agents -- that support the Compaq Host OS MIB. -- -- **************************************************************************** cpqHoIfPhysMapTable OBJECT-TYPE SYNTAX SEQUENCE OF CpqHoIfPhysMapEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "A table of interface to physical hardware mappings." ::= { cpqHoIfPhysMap 1 } cpqHoIfPhysMapEntry OBJECT-TYPE SYNTAX CpqHoIfPhysMapEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "A mapping of an interface table entry to physical hardware." INDEX { cpqHoIfPhysMapIndex } ::= { cpqHoIfPhysMapTable 1 } CpqHoIfPhysMapEntry ::= SEQUENCE { cpqHoIfPhysMapIndex INTEGER, cpqHoIfPhysMapSlot INTEGER, cpqHoIfPhysMapIoBaseAddr INTEGER, cpqHoIfPhysMapIrq INTEGER, cpqHoIfPhysMapDma INTEGER, cpqHoIfPhysMapMemBaseAddr INTEGER, cpqHoIfPhysMapPort INTEGER, cpqHoIfPhysMapDuplexState INTEGER, cpqHoIfPhysMapCondition INTEGER } cpqHoIfPhysMapIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS deprecated DESCRIPTION "An index that uniquely specifies this entry. This value is equal to the index of the entry in the MIB-II interface table to which this entry corresponds." ::= { cpqHoIfPhysMapEntry 1 } cpqHoIfPhysMapSlot OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS deprecated DESCRIPTION "The number of the slot containing the physical hardware that implements this interface. The number zero (0) indicates an embedded interface (on the system board) or an interface whose slot is unknown. Values may be unknown if the physical hardware has not been configured using the EISA Configuration Utility." ::= { cpqHoIfPhysMapEntry 2 } cpqHoIfPhysMapIoBaseAddr OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS deprecated DESCRIPTION "The base I/O address of the physical hardware that implements this interface." ::= { cpqHoIfPhysMapEntry 3 } cpqHoIfPhysMapIrq OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS deprecated DESCRIPTION "The number of the IRQ (interrupt) used for this physical hardware interface. The number zero (0) indicates that this device does not use an IRQ or this information is unavailable." ::= { cpqHoIfPhysMapEntry 4 } cpqHoIfPhysMapDma OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS deprecated DESCRIPTION "The number of the DMA channel used for this physical hardware interface. The number -1 indicates that this device does not use a DMA channel or this information is unavailable." ::= { cpqHoIfPhysMapEntry 5 } cpqHoIfPhysMapMemBaseAddr OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS deprecated DESCRIPTION "The base memory address used by this physical hardware interface. The number zero (0) indicates that this device does not use system memory or this information is unavailable." ::= { cpqHoIfPhysMapEntry 6 } cpqHoIfPhysMapPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS deprecated DESCRIPTION "The port number of the interface for multi-port NICs. A port number of -1 indicates that the port could not be determined." -- :CPQ,DEV: -- This value is intended to match the labeling of the ports on the -- physical connectors. I hope this will be a consistent 1-based -- scheme but it is defined in a way to handle 0-based as well. -- -- Single port NICs should return a 1. -- :CPQ,ENDDEV: ::= { cpqHoIfPhysMapEntry 7 } cpqHoIfPhysMapDuplexState OBJECT-TYPE SYNTAX INTEGER { other(1), -- default half(2), full(3) } ACCESS read-only STATUS deprecated DESCRIPTION "This variable describes the configured duplex state of the NIC." -- :CPQ,DEV: -- Agents should return Other(1) for NIC types that they do not support -- the ability to get status from. -- :CPQ,ENDDEV: ::= { cpqHoIfPhysMapEntry 8 } cpqHoIfPhysMapCondition OBJECT-TYPE SYNTAX INTEGER { other(1), -- default ok(2), degraded(3), failed(4) } ACCESS read-only STATUS deprecated DESCRIPTION "The condition of this interface." -- :CPQ,DEV: -- Agents should return Other(1) for NIC types that do not support -- the ability to the NIC condition. -- :CPQ,ENDDEV: ::= { cpqHoIfPhysMapEntry 9 } cpqHoIfPhysMapOverallCondition OBJECT-TYPE SYNTAX INTEGER { other(1), -- default ok(2), degraded(3), failed(4) } ACCESS read-only STATUS deprecated DESCRIPTION "The overall condition of all interfaces." ::= { cpqHoIfPhysMap 2 } -- **************************************************************************** -- Host OS Software Running Table -- ============================== -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHostOs Group (1.3.6.1.4.1.232.11) -- cpqHoComponent Group (1.3.6.1.4.1.232.11.2) -- cpqHoSWRunning Group (1.3.6.1.4.1.232.11.2.6) -- cpqHoSWRunningTable (1.3.6.1.4.1.232.11.2.6.1) -- cpqHoSwRunningTrapDesc (1.3.6.1.4.1.232.11.2.6.2) -- -- -- The cpqHoSWRunning group contains configuration and status information -- about the software running on the host OS. -- -- Implementation of the cpqHoSWRunning group is optional for agents -- that support the Compaq Host OS MIB. -- -- **************************************************************************** cpqHoSWRunningTable OBJECT-TYPE SYNTAX SEQUENCE OF CpqHoSWRunningEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of descriptions of software running on the system." ::= { cpqHoSWRunning 1 } cpqHoSWRunningEntry OBJECT-TYPE SYNTAX CpqHoSWRunningEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A description of a software program running on the system." INDEX { cpqHoSWRunningIndex } ::= { cpqHoSWRunningTable 1 } CpqHoSWRunningEntry ::= SEQUENCE { cpqHoSWRunningIndex INTEGER, cpqHoSWRunningName DisplayString, cpqHoSWRunningDesc DisplayString, cpqHoSWRunningVersion DisplayString, cpqHoSWRunningDate OCTET STRING, cpqHoSWRunningMonitor INTEGER, cpqHoSWRunningState INTEGER } cpqHoSWRunningIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "An index that uniquely specifies this entry." ::= { cpqHoSWRunningEntry 1 } cpqHoSWRunningName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The name of the software." ::= { cpqHoSWRunningEntry 2 } cpqHoSWRunningDesc OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "A description of the software." ::= { cpqHoSWRunningEntry 3 } cpqHoSWRunningVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The version of the software. This field will be a null (size 0) string if the agent cannot provide the software version." ::= { cpqHoSWRunningEntry 4 } cpqHoSWRunningDate OBJECT-TYPE SYNTAX OCTET STRING (SIZE (7)) ACCESS read-only STATUS mandatory DESCRIPTION "The software date. field octets contents range ===== ====== ======= ===== 1 1-2 year 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minute 0..59 6 7 second 0..60 (use 60 for leap-second) This field will be set to year = 0 if the agent cannot provide the software date. The hour, minute, and second field will be set to zero (0) if they are not relevant." ::= { cpqHoSWRunningEntry 5 } cpqHoSWRunningMonitor OBJECT-TYPE SYNTAX INTEGER { other(1), -- default start(2), stop(3), startAndStop(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The user specified monitor option for a process." ::= { cpqHoSWRunningEntry 6 } cpqHoSWRunningState OBJECT-TYPE SYNTAX INTEGER { other(1), -- default started(2), stopped(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The current state of monitored process." ::= { cpqHoSWRunningEntry 7 } cpqHoSwRunningTrapDesc OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The error message for a process monitor event." ::= { cpqHoSWRunning 2 } -- **************************************************************************** -- Config Software Version Instrumentation Group -- =============================================== -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHostOs Group (1.3.6.1.4.1.232.11) -- cpqHoComponent Group (1.3.6.1.4.1.232.11.2) -- cpqHoSwVer Group (1.3.6.1.4.1.232.11.2.7) -- cpqHoSwVerTable (1.3.6.1.4.1.232.11.2.7.2) -- -- The cpqSwVer group describes the software version table. -- -- Implementation of the cpqSwVer group is mandatory for all -- agents that support the Compaq Host MIB. -- -- The read-write elements of this table should be saved from instance to -- instance of the agent. -- -- This table can be added to by writing to the cpqHoSwVerName (using the -- cpqHoSwVerNextIndex index) field with a new driver name. Writing to -- this field causes the creation of a new table row (and any data that can -- be obtained will be filled in, the remainder will be set to the defaults.) -- -- A row may be deleted by writing to the cpqHoSwVerName field with a null -- entry. -- **************************************************************************** cpqHoSwVerNextIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of the next available entry in the cpqHoSwVer table. If the maximum number of entries to the cpqHoSwVer table has been reached, this index will contain -1." -- -- Writing to the cpqHoSwVerName variable using this index will cause a new -- entry in the table to be created. -- ::= { cpqHoSwVer 1 } cpqHoSwVerTable OBJECT-TYPE SYNTAX SEQUENCE OF CpqHoSwVerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of software item entries." ::= { cpqHoSwVer 2 } cpqHoSwVerEntry OBJECT-TYPE SYNTAX CpqHoSwVerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of software items that are on the machine." INDEX { cpqHoSwVerIndex } ::= { cpqHoSwVerTable 1 } CpqHoSwVerEntry ::= SEQUENCE { cpqHoSwVerIndex INTEGER, cpqHoSwVerStatus INTEGER, cpqHoSwVerType INTEGER, cpqHoSwVerName DisplayString, cpqHoSwVerDescription DisplayString, cpqHoSwVerDate OCTET STRING, cpqHoSwVerLocation DisplayString, cpqHoSwVerVersion DisplayString } cpqHoSwVerIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "An index that uniquely identifies an entry in the cpqHoSwVer table." ::= { cpqHoSwVerEntry 1 } cpqHoSwVerStatus OBJECT-TYPE SYNTAX INTEGER { other(1), -- undefined (default) loaded(2), -- and running notloaded(3) -- found but not loaded } ACCESS read-only STATUS mandatory DESCRIPTION "Status for the software item." -- -- Items of type 'other' are those items which the agent could -- not locate. -- ::= { cpqHoSwVerEntry 2 } cpqHoSwVerType OBJECT-TYPE SYNTAX INTEGER { other(1), driver(2), -- (default) agent(3), sysutil(4), application(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Type of software item." -- :CPQ,DEV: -- -- Enumerations are: -- other - undefined -- driver - an NPFC, NTSSD, OS/2 SSD, or UNIX EFS driver -- agent - Insight Agent subsystem -- sysutil - utility on the system parition, cf. cpqHoSwVerName -- application - CIM, on-line blazer, SSMU, etc. -- -- :CPQ,ENDDEV: ::= { cpqHoSwVerEntry 3 } cpqHoSwVerName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..127)) ACCESS read-write STATUS mandatory DESCRIPTION "The name of this software item." -- -- Writing to this entry with an index equal to cpqHoSwVerNextIndex -- causes a table row to be created, and all entries to be filled in. -- -- Writing to this entry with a NULL name deletes the current row. -- -- :CPQ,DEV: -- -- For cpqHoSwVerType DRIVER: -- For cpqHoSwVerType AGENT: -- - filename of driver -- For cpqHoSwVerType SYSUTIL: -- CONFIG - System Config (from EV CQHUV) -- SYSTEMROMPAQ - System ROMPaq (from EV CQHUV) -- DIAGS - Diagnostics (from EV CQHUV) -- DISKDR - DiskDoctor (from EV CQHUV) -- OPTIONROMPAQ - Option ROMPaq (from EV CQHUV) -- -- Writing to this entry can cause the entire row to be updated. -- -- :CPQ,ENDDEV: ::= { cpqHoSwVerEntry 4 } cpqHoSwVerDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..127)) ACCESS read-write STATUS mandatory DESCRIPTION "The description of this software item." -- -- A length of 0 indicates that the description of this item is -- not available. -- -- Writing to this entry can cause the entire row to be updated. -- ::= { cpqHoSwVerEntry 5 } cpqHoSwVerDate OBJECT-TYPE SYNTAX OCTET STRING (SIZE (7)) ACCESS read-only STATUS mandatory DESCRIPTION "The date of the software item, if any. field octets contents range ===== ====== ======= ===== 1 1-2 year 0..65535 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minute 0..59 6 7 second 0..60 (use 60 for leap-second) The year field is set with the most significant octect first. An entry of zero (0) means that there is no date associated with this software item. Zero is the default." ::= { cpqHoSwVerEntry 6 } cpqHoSwVerLocation OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "The location of this software item on the server." -- :CPQ,DEV: -- -- Should be: -- for drivers and agents -- "System Parition" for system utilities -- -- A length of 0 indicates that the location of this item is -- not available (the default.) -- -- Writing to this location can cause the updating of the entire -- entry. The agents may use this variable as a hint to finding -- the item. -- -- :CPQ,ENDDEV: ::= { cpqHoSwVerEntry 7 } cpqHoSwVerVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (0..50)) ACCESS read-only STATUS mandatory DESCRIPTION "An string that specifies the version of this item." -- :CPQ,DEV: -- -- For Compaq software, this variable should be of the form -- XX.XX[.XX]aa with major and first minor revisions seperated -- by a period (.). The second minor revision is optional. -- -- X - any integer 0-9 -- a - any letter a-z (case is unimportant) -- -- 0.0 is the default -- -- -- For 3rd Party software, this variable has no predefined form. -- -- :CPQ,ENDDEV: ::= { cpqHoSwVerEntry 8 } -- **************************************************************************** -- The cpqHoGeneric group holds only the generic trap -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHostOS Group (1.3.6.1.4.1.232.11) -- cpqHoComponent Group (1.3.6.1.4.1.232.11.2) -- cpqHoGeneric Group (1.3.6.1.4.1.232.11.2.8) -- -- Implementation of this group is optional. -- -- **************************************************************************** cpqHoGenericData OBJECT-TYPE SYNTAX DisplayString (SIZE (0..254)) ACCESS read-write STATUS mandatory DESCRIPTION "Data for the generic trap." -- -- This is the data variable that is sent with the generic trap below. -- -- Writing to this variable will cause the generic trap to be sent with -- the newly written data. -- ::= { cpqHoGeneric 1 } -- **************************************************************************** -- Software Performance Group -- =========================== -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHostOS Group (1.3.6.1.4.1.232.11) -- cpqHoComponent Group (1.3.6.1.4.1.232.11.2) -- cpqHoSwPerf Group (1.3.6.1.4.1.232.11.2.9) -- -- Implementation of this group is optional. -- -- **************************************************************************** cpqHoSwPerfAppErrorDesc OBJECT-TYPE SYNTAX DisplayString (SIZE (0..254)) ACCESS read-only STATUS mandatory DESCRIPTION " This string holds error information about the last application error that occurred in the system. " ::= { cpqHoSwPerf 1 } -- **************************************************************************** -- System Status Group -- =================== -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHostOS Group (1.3.6.1.4.1.232.11) -- cpqHoComponent Group (1.3.6.1.4.1.232.11.2) -- cpqHoSystemStatus Group (1.3.6.1.4.1.232.11.2.10) -- -- Implementation of this group is mandatory. -- -- **************************************************************************** cpqHoMibStatusArray OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4..256)) ACCESS read-only STATUS mandatory DESCRIPTION "The MIB Status Array is an array of MIB status structures. Each structure is made up of 4 octets. The first octet is the MIB presence. The second octet is MIB condition. The third octet is MIB major revision. The fourth octet is MIB minor revision. Status This is a collection of flags. Each bit has the following meaning when it is on (1): Bit 2-7: RESERVED: Always 0 Bit 1: MIB is from offline data (only applies to global system status) Bit 0: MIB is available NOTE: bit 7 is the most significant bit, bit 0 is the least significant. Condition 0 - Not available 1 - Other 2 - OK 3 - Degraded 4 - Failed Major Revison 0..255, where 0 is not available Minor Revision 0..255, where 0 is not available Array element 0 is the status for all MIBs in the Compaq Enterprise. Array element n, where n > 0, is the status for the nth MIB in the Compaq Enterprise (.1.3.6.1.4.1.232.n). Octet Element Field ======== ======= ========= 0 0 Status of any Compaq MIBs 1 Condition of all Compaq MIBs 2 System Flags (see below) 3 Reserved - always 0 4 1 Status of Compaq MIB 1 5 Condition of Compaq MIB 1 6 Major Revision of Compaq MIB 1 7 Minor Revision of Compaq MIB 1 8 2 Status of Compaq MIB 2 9 Condition of Compaq MIB 2 10 Major Revision of Compaq MIB 2 11 Minor Revision of Compaq MIB 2 . . . . n*4 n Status of Compaq MIB n (n*4)+1 Condition of Compaq MIB n (n*4)+2 Major Revision of Compaq MIB n (n*4)+3 Minor Revision of Compaq MIB n System Flags (octet 2) Bit Meaning ===== ========= 0 Equals 1 if the device is running Desktop Management Agents Equals 0 if the device is running Server Management Agents 1 This system contains enabled remote console functionality. 2 This system is configured to be an Integration Server. 3 Web Based Management is enabled. 4-7 Reserved (reserved Bits should be zero)" -- :CPQ,DEV: -- Array element 0 is the global status for all Compaq MIBs -- (.1.3.6.1.4.1.232) -- Status MIB is available (0x01) is the default. When the MIB -- is being provided by a FLINT board in the offline state, -- this value is MIB is available and from offline data -- (0x03). -- MajorRev is 0 -- MinorRev is 0 -- Condition is the combination of all the conditions of MIBs 1..n -- Array element n, for n > 0, is the status of the nth Compaq MIB -- (.1.3.6.1.4.1.232.n) -- Presence is available(1) if .1.3.6.1.4.1.232.n exists, otherwise -- it is not available(0). -- MajorRev is from .1.3.6.1.4.1.232.n.1.1 -- MinorRev is from .1.3.6.1.4.1.232.n.1.2 -- Condition is from .1.3.6.1.4.1.232.n.1.3 -- :CPQ,ENDDEV: ::= { cpqHoSystemStatus 1 } cpqHoConfigChangedDate OBJECT-TYPE SYNTAX OCTET STRING (SIZE (7)) ACCESS read-only STATUS mandatory DESCRIPTION "The date/time when the agents were last loaded. field octets contents range ===== ====== ======= ===== 1 1-2 year 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minute 0..59 6 7 second 0..60 (use 60 for leap-second) This field will be set to year = 0 if the agent cannot provide the date/time. The year field is set with the most significant octect first." -- :CPQ,DEV: -- This variable was added in the v3.00 timeframe. This initial -- release of the agents will modify this variable when the agents -- are initially loaded. Future development may provide enhancements -- so that this variable changes significant hardware configurations -- occur (i.e., hot plugged drives, etc). -- :CPQ,ENDDEV: ::= { cpqHoSystemStatus 2 } cpqHoGUID OBJECT-TYPE SYNTAX OCTET STRING (SIZE (16)) ACCESS read-write STATUS mandatory DESCRIPTION "The globally unique identifier of this server. If the OS cannot determine a unique ID, it will default the variable to contain all 0's. The management station can then perform a SET to this variable to provide the unique ID." ::= { cpqHoSystemStatus 3 } cpqHoCodeServer OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This item indicates how many code server shares are currently configured on the system. If the value of this attribute is 0, this server has not been configured with code server shares." ::= { cpqHoSystemStatus 4 } cpqHoWebMgmtPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This item indicates the port used by the Insight Web Agent. If the port cannot be determined or the Web Management agent is not enabled, this value will be -1." ::= { cpqHoSystemStatus 5 } -- **************************************************************************** -- Trap Info Group -- ================ -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHostOS Group (1.3.6.1.4.1.232.11) -- cpqHoComponent Group (1.3.6.1.4.1.232.11.2) -- cpqHoTrapInfo Group (1.3.6.1.4.1.232.11.2.11) -- -- Implementation of this group is mandatory. -- -- **************************************************************************** cpqHoTrapFlags OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The Trap Flags. This is a collection of flags used during trap delivery. Each bit has the following meaning: Bit 2-31: RESERVED: Always 0. Bit 1: Client IP address type 0 = static entry 1 = DHCP entry Bit 0: Agent Type 0 = Server 1 = Client NOTE: bit 31 is the most significant bit, bit 0 is the least significant." -- :CPQ,DEV: -- The variable is only valid when bound in a trap. -- :CPQ,ENDDEV: ::= { cpqHoTrapInfo 1 } -- **************************************************************************** -- OS Client Table -- ==================== -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHostOS Group (1.3.6.1.4.1.232.11) -- cpqHoComponent Group (1.3.6.1.4.1.232.11.2) --- cpqHoClient Group (1.3.6.1.4.1.232.11.2.12) -- -- The cpqHoClient table contains entries describing identification, -- address, and status information about each unit that is using -- services provided by this unit. -- -- **************************************************************************** cpqHoClientLastModified OBJECT-TYPE SYNTAX OCTET STRING (SIZE (7)) ACCESS read-only STATUS mandatory DESCRIPTION "The date/time of the last modification to the client table. field octets contents range ===== ====== ======= ===== 1 1-2 year 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minute 0..59 6 7 second 0..60 (use 60 for leap-second) This field will be set to all 0's if there are no entries to the client table. The year field will be set to 0xFFFF if the agent does not support the client table. The year field is set with the most significant octect first." -- :CPQ,DEV: -- This variable must be supported by agents that support the Host MIB. -- The table below is optional. If an agent does not support the table, -- the LastModified year value will be 0xFFFF. -- :CPQ,ENDDEV: ::= { cpqHoClients 1 } cpqHoClientDelete OBJECT-TYPE SYNTAX DisplayString (SIZE (0..15)) ACCESS read-write STATUS mandatory DESCRIPTION "Setting this variable to the name of a client in the client table will cause that row in the table to be deleted. Any other set will fail. Note that the indices of the table will (most likely) be renumbered following a deletion." ::= { cpqHoClients 2 } cpqHoClientTable OBJECT-TYPE SYNTAX SEQUENCE OF CpqHoClientEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of client descriptions." ::= { cpqHoClients 3 } cpqHoClientEntry OBJECT-TYPE SYNTAX CpqHoClientEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A client description." INDEX { cpqHoClientIndex } ::= { cpqHoClientTable 1 } CpqHoClientEntry ::= SEQUENCE { cpqHoClientIndex INTEGER, cpqHoClientName DisplayString, cpqHoClientIpxAddress OCTET STRING, cpqHoClientIpAddress IpAddress, cpqHoClientCommunity DisplayString, cpqHoClientID OCTET STRING } cpqHoClientIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "An index that uniquely specifies this entry." ::= { cpqHoClientEntry 1 } cpqHoClientName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..15)) ACCESS read-only STATUS mandatory DESCRIPTION "The Win95 machine name of this client." -- Note that Win95 limits the machine name to a maximum of 15 characters. ::= { cpqHoClientEntry 2 } cpqHoClientIpxAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE (20)) ACCESS read-only STATUS mandatory DESCRIPTION "The IPX address for this client, all octets should be set to 0xff if this machine does not support IPX. The format is NetAddr:NodeNumber and sent in MSB order: 1111111111 01234567:890123456789" -- Note, this item is still in definition and probably will change. ::= { cpqHoClientEntry 3 } cpqHoClientIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The IP address for this client, all octets should be set to 0xff if this machine does not support IP. The order will be in network byte order (ie MSB first.)" ::= { cpqHoClientEntry 4 } cpqHoClientCommunity OBJECT-TYPE SYNTAX DisplayString (SIZE (0..48)) ACCESS read-only STATUS mandatory DESCRIPTION "A community name that can be used to query the client with SNMP. This community name should have, but is not required to have, the greatest possible access to client information." ::= { cpqHoClientEntry 5 } cpqHoClientID OBJECT-TYPE SYNTAX OCTET STRING (SIZE (16)) ACCESS read-only STATUS mandatory DESCRIPTION "The unique identifier of this client." ::= { cpqHoClientEntry 6 } -- **************************************************************************** -- OS Memory Group -- =============== -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHostOS Group (1.3.6.1.4.1.232.11) -- cpqHoComponent Group (1.3.6.1.4.1.232.11.2) --- cpqHoMemory Group (1.3.6.1.4.1.232.11.2.13) -- -- The cpqHoMemory group contains entries describing memory -- as seen by the OS. -- -- **************************************************************************** cpqHoPhysicalMemorySize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Total amount of physical memory as seen by the OS (in megabytes). A -1 will be returned if this value could not be determined." ::= { cpqHoMemory 1 } cpqHoPhysicalMemoryFree OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The amount of free physical memory (in megabytes). A -1 will be returned if this value could not be determined." ::= { cpqHoMemory 2 } cpqHoPagingMemorySize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Total virtual memory available from the OS (in megabytes). A -1 will be returned if this value could not be determined." ::= { cpqHoMemory 3 } cpqHoPagingMemoryFree OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Available paging memory (in megabytes). A -1 will be returned if this value could not be determined." ::= { cpqHoMemory 4 } -- **************************************************************************** -- Host MIB Trap Definitions -- ========================= -- -- The SNMP trap messages must not be bigger than 484 octets (bytes). -- -- Trap support in an SNMP agent implementation is optional. An SNMP -- agent implementation may support all, some, or none of the traps. -- If traps are supported, The user should be provided with the option of -- disabling traps. -- -- Implementation of cpqHoGenericTrap is a mandatory part of the Generic -- group. -- -- ************************************************************************** cpqHoGenericTrap TRAP-TYPE ENTERPRISE compaq VARIABLES { cpqHoGenericData } DESCRIPTION -- This trap is a generic trap, and left undefined. "Generic trap." --#TYPE "Generic trap" --#SUMMARY "%s" --#ARGUMENTS {0} --#SEVERITY MAJOR --#TIMEINDEX 99 -- :CPQ,DEV: -- -- This is for the agents to expose an API for 3rd parties to be -- able to easily generate a trap. -- -- It is recommended that the agents support the API: -- -- int CpqGenericTrap(char *string) -- -- -- -- -- -- -- -- :CPQ,ENDDEV: ::= 11001 cpqHoAppErrorTrap TRAP-TYPE ENTERPRISE compaq VARIABLES { cpqHoSwPerfAppErrorDesc } DESCRIPTION "An application has generated an exception. Specific error information is contained in the variable cpqHoSwPerfAppErrorDesc." --#TYPE "Application Error Trap" --#SUMMARY "%s" --#ARGUMENTS {0} --#SEVERITY MAJOR --#TIMEINDEX 99 ::= 11002 -- :CPQ,DEV: -- The above trap definitions are deprecated in release 2.60. Traps in -- version 2.60 and greater have the system name and trap flags variables -- bound to all traps. -- :CPQ,ENDDEV: cpqHo2GenericTrap TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqHoGenericData } DESCRIPTION -- This trap is a generic trap, and left undefined. "Generic trap." --#TYPE "Generic trap" --#SUMMARY "%s" --#ARGUMENTS {2} --#SEVERITY MAJOR --#TIMEINDEX 99 -- :CPQ,DEV: -- -- This is for the agents to expose an API for 3rd parties to be -- able to easily generate a trap. -- -- It is recommended that the agents support the API: -- -- int CpqGenericTrap(char *string) -- -- -- -- -- -- -- -- :CPQ,ENDDEV: ::= 11003 cpqHo2AppErrorTrap TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqHoSwPerfAppErrorDesc } DESCRIPTION "An application has generated an exception. Specific error information is contained in the variable cpqHoSwPerfAppErrorDesc." --#TYPE "Application Error Trap" --#SUMMARY "%s" --#ARGUMENTS {2} --#SEVERITY MAJOR --#TIMEINDEX 99 ::= 11004 cpqHo2NicStatusOk TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqHoIfPhysMapSlot } DESCRIPTION "This trap will be sent any time the status of a NIC changes to the OK condition." --#TYPE "Status Trap" --#SUMMARY "NIC Status is OK for slot %s." --#ARGUMENTS {2} --#SEVERITY MAJOR --#TIMEINDEX 99 ::= 11005 cpqHo2NicStatusFailed TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqHoIfPhysMapSlot } DESCRIPTION "This trap will be sent any time the status of a NIC changes to the Failed condition." --#TYPE "Status Trap" --#SUMMARY "NIC Status is Failed for slot %s." --#ARGUMENTS {2} --#SEVERITY MAJOR --#TIMEINDEX 99 ::= 11006 cpqHo2NicSwitchoverOccurred TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqHoIfPhysMapSlot, cpqHoIfPhysMapSlot } DESCRIPTION "This trap will be sent any time the configured redundant NIC becomes the active NIC." --#TYPE "Status Trap" --#SUMMARY "NIC switchover to slot %s from slot %s." --#ARGUMENTS {2, 3} --#SEVERITY MAJOR --#TIMEINDEX 99 -- :CPQ,DEV: -- The first instance of cpqHoIfPhysMapSlot is the new primary -- NIC. The second instanse of cpqHoIfPhysMapSlot is the old -- primary NIC. -- :CPQ,ENDDEV: ::= 11007 -- :CPQ,DEV: -- The NIC trap definitions below were deprecated in release 4.20. -- :CPQ,ENDDEV: cpqHo2NicStatusOk2 TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqHoIfPhysMapSlot, cpqHoIfPhysMapPort } DESCRIPTION "This trap will be sent any time the status of a NIC changes to the OK condition." --#TYPE "Status Trap" --#SUMMARY "NIC Status is OK for slot %s, port %s." --#ARGUMENTS {2, 3} --#SEVERITY MAJOR --#TIMEINDEX 99 ::= 11008 cpqHo2NicStatusFailed2 TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqHoIfPhysMapSlot, cpqHoIfPhysMapPort } DESCRIPTION "This trap will be sent any time the status of a NIC changes to the Failed condition." --#TYPE "Status Trap" --#SUMMARY "NIC Status is Failed for slot %s, port %s." --#ARGUMENTS {2, 3} --#SEVERITY MAJOR --#TIMEINDEX 99 ::= 11009 cpqHo2NicSwitchoverOccurred2 TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqHoIfPhysMapSlot, cpqHoIfPhysMapPort, cpqHoIfPhysMapSlot, cpqHoIfPhysMapPort } DESCRIPTION "This trap will be sent any time the configured redundant NIC becomes the active NIC." --#TYPE "Status Trap" --#SUMMARY "NIC switchover to slot %s, port %s from slot %s, port %s." --#ARGUMENTS {2, 3, 4, 5} --#SEVERITY MAJOR --#TIMEINDEX 99 -- :CPQ,DEV: -- The first instance of cpqHoIfPhysMapSlot/Port is the new primary -- NIC. The second instanse of cpqHoIfPhysMapSlot/Port is the old -- primary NIC. -- :CPQ,ENDDEV: ::= 11010 cpqHoProcessEventTrap TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqHoSwRunningTrapDesc } DESCRIPTION "A monitored process has either started or stopped running." --#TYPE "Process Monitor Event Trap" --#SUMMARY "%s" --#ARGUMENTS {2} --#SEVERITY MAJOR --#TIMEINDEX 99 ::= 11011 END