-- $Id: shiva-nme.asn,v 1.5 1996/04/02 11:28:54 jas Exp $ -- -- Copyright 1992, 1993, 1995, 1996 Shiva Corporation -- -- -- NetModem/E MIB -- -- Only implemented on platforms using the SAM operating -- environment: NetModem 1.x, LanRover/E for IPX 1.x. This -- MIB is NOT implemented on later releases of these products -- nor on any other products. SHIVA-NME-MIB DEFINITIONS ::= BEGIN IMPORTS TimeTicks FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 -- Concise MIB Definitions nmv32e FROM SHIVA-MIB; mport OBJECT IDENTIFIER ::= { nmv32e 1 } ipxcp OBJECT IDENTIFIER ::= { nmv32e 2 } ipxelap OBJECT IDENTIFIER ::= { nmv32e 3 } rip OBJECT IDENTIFIER ::= { nmv32e 4 } ipx OBJECT IDENTIFIER ::= { nmv32e 5 } modem OBJECT IDENTIFIER ::= { nmv32e 6 } ripDefaultNet OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The default IPX network number for the ethernet interface" ::= { rip 1 } ipxcpTable OBJECT-TYPE SYNTAX SEQUENCE OF IpxcpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of IPX control protocol settings, which probably don't really need to be in a table." ::= { ipxcp 1 } ipxcpEntry OBJECT-TYPE SYNTAX IpxcpEntry ACCESS not-accessible STATUS mandatory INDEX { INTEGER } -- ??? ::= { ipxcpTable 1 } IpxcpEntry ::= SEQUENCE { ipxcpDialinNet INTEGER } ipxcpDialinNet OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The IPX network number which will be assigned to a dial-in client on this port. Since this isn't really going to get instanced on a per-port basis, we should lose the table stuff." ::= { ipxcpEntry 1 } ipxelapFrameType OBJECT-TYPE SYNTAX INTEGER { typeEther802-3(0), typeEthernet2(1), typeEtherSNAP(2), typeAutosense(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The framing type used by the ethernet interface. typeAutosense not supported in rev 1.0.X firmware" ::= { ipxelap 1 } ipxRouteNetBIOS OBJECT-TYPE SYNTAX INTEGER { unidirectional(0), bidirectional(1) } ACCESS read-write STATUS mandatory DESCRIPTION "If this variable is 'bidirectional' the NetModem/E will do full routing of Novell NetBIOS. Otherwise it will only forward NetBIOS broadcasts which originate from a single-user dialin access node." ::= { ipx 1 } mportTable OBJECT-TYPE SYNTAX SEQUENCE OF MportEntry ACCESS not-accessible STATUS mandatory ::= { mport 1 } mportEntry OBJECT-TYPE SYNTAX MportEntry ACCESS not-accessible STATUS mandatory INDEX { INTEGER } -- ??? ::= { mportTable 1 } MportEntry ::= SEQUENCE { mportPortName OCTET STRING, mportIdleTime TimeTicks, mportIdleStatus INTEGER, mportStatus INTEGER, mportUsername OCTET STRING, mportPermissions INTEGER, mportCCLName OCTET STRING, mportCCLData OCTET STRING, mportBaudRate INTEGER, mportFlowControl INTEGER, mportCurrentIdleTime TimeTicks, mportCurrentConnectTime TimeTicks, mportDTESignals INTEGER } mportPortName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (47)) ACCESS read-write STATUS mandatory DESCRIPTION "The specific name of the port. This is used as the SAP name of a NetModem/E." ::= { mportEntry 1 } mportIdleTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-write STATUS mandatory DESCRIPTION "The time (in 0.01 second units) to allow a dialout connection to stay idle before disconnecting the user." ::= { mportEntry 2 } mportIdleStatus OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates whether or not dial-out idle detection is active." ::= { mportEntry 3 } mportStatus OBJECT-TYPE SYNTAX INTEGER { idle(0), -- doing nothing dialout(1), -- shared serial routing(2), -- acting as a half-router dialin(3), -- serving one end node arap(4), -- equivalent to dialin, but using ARAP off(5) -- this port won't leave this -- state unless this -- variable is set to idle(0) } ACCESS read-write STATUS mandatory DESCRIPTION "The current status of this port." ::= { mportEntry 4 } mportUsername OBJECT-TYPE SYNTAX OCTET STRING (SIZE (32)) ACCESS read-only STATUS mandatory DESCRIPTION "The name of the user currently attached to this port." ::= { mportEntry 5 } mportPermissions OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The specific permissions enabled for this port." ::= { mportEntry 6 } mportCCLName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "The title of the CCL script assigned to this port." ::= { mportEntry 7 } mportCCLData OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "As-yet undefined CCL script code." ::= { mportEntry 8 } mportBaudRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The default start-up baud rate of this port." ::= { mportEntry 9 } mportFlowControl OBJECT-TYPE SYNTAX INTEGER { none(1), xonxoff(2), rtscts(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The flow control setting for this port. This is ignored in systems with internal modems." ::= { mportEntry 10 } mportCurrentIdleTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The amount of time the current connection has been idle." ::= { mportEntry 11 } mportCurrentConnectTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The amount of time since the current connection was established." ::= { mportEntry 12 } mportDTESignals OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The current DTE signals on this port stored as a a bit mask which holds the following flags: 0x80 DCD 0x40 DSR 0x20 DTR 0x10 RTS 0x08 CTS" ::= { mportEntry 13 } mportDeviceName OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The server name advertised by a LanRover/E" ::= { mport 2 } mportDialinIdleTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-write STATUS mandatory DESCRIPTION "The time (in 0.01 second units) to allow a PPP dial-in connection to stay idle before disconnecting the user." ::= { mport 3 } mportDialinIdleStatus OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates whether or not a PPP dial-in idle detection is active." ::= { mport 4 } -- -- modem statistics and information specific to the NetModem/E -- modemCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "How many modems are in this product." ::= { modem 1 } modemTable OBJECT-TYPE SYNTAX SEQUENCE OF ModemEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table which describes the state of all of the modems in the product." ::= { modem 2 } modemEntry OBJECT-TYPE SYNTAX ModemEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The description record for a particular modem, indexed by the modem's modemIndex value." INDEX { modemIndex } ::= { modemTable 1 } ModemEntry ::= SEQUENCE { modemIndex INTEGER, modemState INTEGER, modemModulationType INTEGER, modemModulationRate INTEGER, modemErrorCorrection INTEGER, modemDataCompression INTEGER, modemMeanSquareError INTEGER, modemRetrainCount INTEGER, modemRetrainTime TimeTicks } modemIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The ordinal number of this modem, from 1..modemCount" ::= { modemEntry 1 } modemState OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The state of the modem, expressed as a bitmap of boolean values; Bit Meaning 0 Off-Hook 1 Carrier Detect 2 Command Mode" ::= { modemEntry 2 } modemModulationType OBJECT-TYPE SYNTAX INTEGER { bell103(1), bell212A(2), v22(3), v22bis(4), v32(5), v32bis(6), vFast(7) --not supported } ACCESS read-only STATUS mandatory DESCRIPTION "The modulation type of the modem. Valid only if the Carrier Detect bit is set in the modemState." ::= { modemEntry 3 } modemModulationRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The modulation speed in bits per second." ::= { modemEntry 4 } modemErrorCorrection OBJECT-TYPE SYNTAX INTEGER { none(1), lapM(2), -- Link Access Procedure for Modems (V.42) mnp(3) -- Microcom Networking Protocol (V.42 altern) } ACCESS read-only STATUS mandatory DESCRIPTION "The type of error correction protocol in use." ::= { modemEntry 5 } modemDataCompression OBJECT-TYPE SYNTAX INTEGER { none(1), btlz(2), -- British Telecomm Lempel-Ziv (V.42bis) mnp5(3) -- Microcom Networking Protocol Class 5 } ACCESS read-only STATUS mandatory DESCRIPTION "The type of data compression protocol in use." ::= { modemEntry 6 } modemMeanSquareError OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The current mean-square error rate of the modem connection." ::= { modemEntry 7 } modemRetrainCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of times the modems have had to retrain during this connection" ::= { modemEntry 8 } modemRetrainTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The time elapsed since the last train (or retrain) completed." ::= { modemEntry 9 } END