-- ($Id:$) -- Copyright 1998 by Fore Systems, Inc. -- FORE Systems TS-2800 Private MIB -- -- This MIB file corresponds to Version 5.1.1B of the TS-2800 Main Image code. -- -- Changes from the MIB file distributed with Version 3.6.1B: none Fore-TS2800-MIB DEFINITIONS ::= BEGIN IMPORTS TimeTicks, IpAddress, Counter, enterprises FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 DisplayString FROM RFC1213-MIB tokenRing FROM Fore-Common-MIB; -- ---------------------------------------------------------------------------- -- Anchor Points -- ---------------------------------------------------------------------------- ts2800 OBJECT IDENTIFIER ::= { tokenRing 1 } -- sysObjectID ---------------------------------------------------------------- foreSystemsTs2800 OBJECT IDENTIFIER ::= { ts2800 1 } -- Managed Objects ------------------------------------------------------------ tsObjects OBJECT IDENTIFIER ::= { ts2800 2 } tsMain OBJECT IDENTIFIER ::= { tsObjects 1 } -- Configuration Group tsConfig OBJECT IDENTIFIER ::= { tsMain 1 } -- System Management Group tsSys OBJECT IDENTIFIER ::= { tsMain 2 } -- Port Level Management Group tsPort OBJECT IDENTIFIER ::= { tsObjects 2 } -- Domain Management Group tsDmns OBJECT IDENTIFIER ::= { tsObjects 3 } -- Pipe Management Group tsPipe OBJECT IDENTIFIER ::= { tsObjects 4 } -- Filter Management Group tsFilter OBJECT IDENTIFIER ::= { tsObjects 5 } -- Universal Feature Card Group tsUFC OBJECT IDENTIFIER ::= { tsObjects 6 } -- SNMP Information Group tsSnmpInfo OBJECT IDENTIFIER ::= { tsObjects 7 } -- Experimental MIBs ---------------------------------------------------------- tsExpMIBs OBJECT IDENTIFIER ::= { ts2800 3 } dtrMIBs OBJECT IDENTIFIER ::= { tsExpMIBs 1 } -- ---------------------------------------------------------------------------- -- Textual Conventions -- ---------------------------------------------------------------------------- MacAddr ::= OCTET STRING (SIZE(6)) -- From RFC1493 -- ---------------------------------------------------------------------------- -- Configuration Group -- The group consists of: -- - a collection of global objects -- - the trap receiver table -- ---------------------------------------------------------------------------- -- Global Configuration Objects tsFwVer OBJECT-TYPE SYNTAX DisplayString (SIZE (1..64)) ACCESS read-only STATUS mandatory DESCRIPTION "The firmware version in the form major.minor. For port microcode (SOLO) version information see the mgmt.mib-2.interfaces.ifTable.ifEntry.ifDescr object." ::= { tsConfig 1 } tsHwVer OBJECT-TYPE SYNTAX DisplayString (SIZE (1..64)) ACCESS read-only STATUS mandatory DESCRIPTION "The hardware version in the form major.minor." ::= { tsConfig 2 } tsSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (16)) ACCESS read-only STATUS mandatory DESCRIPTION "System serial number." ::= { tsConfig 3 } tsInstallationDate OBJECT-TYPE SYNTAX DisplayString (SIZE (64)) ACCESS read-write STATUS mandatory DESCRIPTION "Firmware installation date. This date is initially set by the Network Management station. Each time the NV RAM is cleared through the console this date needs to be set by the management station. This should be in the format YYYY MM DD HH MM SS." ::= { tsConfig 4 } tsFwSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Size in bytes of the binary firmware image." ::= { tsConfig 5 } tsFwCRC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Firmware binary image CRC value." ::= { tsConfig 6 } tsFwManufacturer OBJECT-TYPE SYNTAX DisplayString (SIZE (16)) ACCESS read-only STATUS mandatory DESCRIPTION "Firmware manufacturer." ::= { tsConfig 7 } -- The IP address and network information below relates to the entire -- switch. Note that each Domain (CRF) also has an address independent -- of those below. tsIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the switch. Changes to this object take effect immediately." ::= { tsConfig 8 } tsNetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP subnet mask of the switch. Changes to this object take effect immediately." ::= { tsConfig 9 } tsDefaultGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP default gateway used by the switch. Changes to this object take effect immediately." ::= { tsConfig 10 } -- Trap Receiver Table tsTrapRcvrTable OBJECT-TYPE SYNTAX SEQUENCE OF tsTrapRcvrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of managers to which to send traps. Entries in the table are saved across resets and power cycles." ::= { tsConfig 14 } tsTrapRcvrEntry OBJECT-TYPE SYNTAX tsTrapRcvrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Definition of rows in the trap receiver table. The column tsTrapRcvrStatus is used to create and delete rows in the table. Creation requires a SET PDU with objects tsTrapRcvrStatus, tsTrapRcvrIpAddress, and tsTrapRcvrComm." INDEX { tsTrapRcvrIndex } ::= { tsTrapRcvrTable 1 } tsTrapRcvrEntry ::= SEQUENCE { tsTrapRcvrIndex INTEGER, tsTrapRcvrStatus INTEGER, tsTrapRcvrIpAddress IpAddress, tsTrapRcvrComm DisplayString, tsTrapRcvrDmns OCTET STRING } tsTrapRcvrIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index of the row in the table." ::= { tsTrapRcvrEntry 1 } tsTrapRcvrStatus OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following valid(2), -- a valid address invalid(3), -- an invalid address create(4) -- create row } ACCESS read-write STATUS mandatory DESCRIPTION "Setting the value of this object to invalid(3) deletes the row from the table. The value invalid(3) should never be returned on a GET. Setting this value to create(4) causes a new row to be created if the row does not already exist. To create a new row set tsTrapRcvrStatus to create(4) and tsTrapRcvrIndex to the next available index ( tsTrapRcvrNext ). After successful creation of the new row, you can then set the desired values for tsTrapRcvrIpAddress and tsTrapRcvrComm. The value returned on GETs should be valid(2) or other(1), which is used to indicate any other condition." ::= { tsTrapRcvrEntry 2 } tsTrapRcvrIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP address for an SNMP manager that is to receive the trap." ::= { tsTrapRcvrEntry 3 } tsTrapRcvrComm OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Community string to use." ::= { tsTrapRcvrEntry 4 } tsTrapRcvrDmns OBJECT-TYPE SYNTAX OCTET STRING (SIZE(8)) ACCESS read-write STATUS mandatory DESCRIPTION "Domains on which traps to this target are sent. Each octet within the value of this object specifies a set of eight domains, with the first octet specifying domains 0 through 7, the second octet specifying domains 8 through 15, etc. Within each octet, the most significant bit represents the lowest numbered domain, and the least significant bit represents the highest numbered domain. Thus, each domain is represented by a single bit within the value of this object. If that bit has a value of '1' then that domain is included in the set of ports which will receive the trap; the domain is not included if its bit has a value of '0'." ::= { tsTrapRcvrEntry 5 } tsPingInterval OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This variable specifies the interval in seconds of sending ICMP Echo Requests to the default gateway. No PING packets will be sent if the value is set to 0. The default interval is 0 minutes." DEFVAL { 0 } ::= { tsConfig 19 } tsTapPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Select the port to monitor traffic." ::= { tsConfig 20 } tsTapMonitoredPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Allows the selection of the port that will be monitored by the port selected by tsTapPort." ::= { tsConfig 21 } tsCrcThresholdHi OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Threshold for the switch to change to store and forward mode. A change in mode also generates a trap." ::= { tsConfig 22 } tsCrcThresholdLow OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Threshold for the switch to change to store and forward mode. A change in mode also generates a trap." ::= { tsConfig 23 } tsPortSwitchModeChangeTrapEnable OBJECT-TYPE SYNTAX INTEGER { enable (1), disable (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable the trap sent out when the switching mode changes from cut-through to store and forward." ::= { tsConfig 24 } tsTrendThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Based on trend calculation of the Dynamic Cut State algorithm, when this value is exceeded the port changes from cut-through to store and forward mode. The default value for this object is 5 events. The valid range is 0-100." ::= { tsConfig 25 } tsSamplingPeriod OBJECT-TYPE SYNTAX INTEGER (1 ..120) ACCESS read-write STATUS mandatory DESCRIPTION "Sampling period in minutes for determining if the error rate of CRC errors has been exceeded. The default value for this object is 10 minutes. The valid range is 1-120." ::= { tsConfig 26 } tsNumberUFC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of UFCs installed in the switch. A value of zero indicates there are NO UFCs installed in this switch. This value indicates the number of entries in the tsUFCTable." ::= { tsConfig 27 } tsMibLvl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The current MIB Level supported by the switch." ::= { tsConfig 28 } tsMgrDomain OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The domain number used in responding to SNMP requests (get/next/set) for multiple instance MIBs such as the Bridge MIB (RFC1493). The default value of this object is the domain number upon which the SNMP request was received from the management station. The management station may SET this value to any valid domain number in order to retreive or change the objects contained in any of the switches multiple instance MIBs. The multiple instance MIBs can be found in the SNMP Info Table." ::= { tsConfig 29 } tsEmbeddedRmonStatus OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The current status of the embedded RMON feature. The The embedded RMON feature may be enabled or disabled by setting this object." ::= { tsConfig 30 } -- ---------------------------------------------------------------------------- -- System management group -- The group consists of: -- - a collection of global objects -- ---------------------------------------------------------------------------- -- Global System Management Objects tsNumPorts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of physical ports on the switch. This value includes all base ports plus all ports on any UFC cards. It does not include internally defined Bridge Relay Function ports or the CPU 'interface'." ::= { tsSys 1 } tsNumStations OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Aggregate number of currently active stations (nodes) on all ports on the switch." ::= { tsSys 2 } tsMostStations OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Highest aggregate number of stations ever active on all ports at one time, since the last reset or power cycle. This includes the default MAC address entries from each port." ::= { tsSys 3 } tsMaxStations OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Highest aggregate number of stations which the switch can support simultaneously." ::= { tsSys 4 } tsReset OBJECT-TYPE SYNTAX INTEGER { running(1), -- switch is running hardReset(2), -- do hard reset of switch softReset(3) -- do soft reset of switch } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to reset the switch. Writing softReset(3) causes the switch to reset the hardware, run quick diagnostics, clear all counters, start switching, issue a warmstart trap, and then be able to respond to SNMP requests. Writing hardReset(2) causes the switch to run power up diagnostics and then execute a soft reset. Note: all address tables are cleared in both cases. The administrative parameters from nonvolatile memory are used to initialize the operational parameters. The value returned on GETs should be running(1)." ::= { tsSys 5 } tsNumResets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of soft resets the switch has executed since the last hard reset or power cycle. Soft resets are defined as writing softReset(3) to tsReset, pressing the front panel reset button, executing a soft reset from the console, or resets induced by the switch firmware." ::= { tsSys 6 } tsAddrAgingTime OBJECT-TYPE SYNTAX INTEGER (0..9999) ACCESS read-write STATUS mandatory DESCRIPTION "Number of minutes of inactivity before an address entity is aged out. A value of zero means no aging. Note: if an address shows up on another port, the original port to address assignment is automatically deleted. The value is saved across resets and power cycles. The default value for this object is 5 minutes." ::= { tsSys 7 } tsSysTemperature OBJECT-TYPE SYNTAX INTEGER { normal (1), toohigh (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Temperature condition of the system. A change in this value generates a TRAP." ::= { tsSys 11 } tsInstalledMemory OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Total amount of CPU memory installed (in megabytes)." ::= { tsSys 12 } tsSysCurTime OBJECT-TYPE SYNTAX DisplayString (SIZE (1 .. 128)) ACCESS read-write STATUS mandatory DESCRIPTION "Current time at the switch. To set the time use the format yyyy mm dd hh mm ss. All fields are required." ::= { tsSys 13 } tsSysPwrStatus OBJECT-TYPE SYNTAX INTEGER { normal(1), inError(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Power supply status of the switch. - normal(1) indicates all power supplies are operating normally. - inError(2) indicates one or more of the power supplies are currently inoperable." ::= { tsSys 14 } tsSysFanStatus OBJECT-TYPE SYNTAX INTEGER { normal(1), inError(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Fan status of the switch. - normal(1) indicates all fans are operating normally. - inError(2) indicates one or more of the fans are currently inoperable." ::= { tsSys 15 } tsSysVoltageStatus OBJECT-TYPE SYNTAX INTEGER { normal(1), low(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Voltage status of the switch. - normal(1) indicates the voltage is within normal limits. - low(2) indicates the voltage is low." ::= { tsSys 16 } -- ---------------------------------------------------------------------------- -- Port Level Management Group -- The group consists of: -- - the port table -- - the optimized port station table -- - the port station table -- ---------------------------------------------------------------------------- -- Port Table tsPortTable OBJECT-TYPE SYNTAX SEQUENCE OF tsPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of information about each port. The number of rows is given by tsNumPorts. (This value refers to PHYSICAL ports as opposed to internal logical CRF bridge ports.)" ::= { tsPort 1 } tsPortEntry OBJECT-TYPE SYNTAX tsPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Definition of rows in the port table. The number of rows is determined by the hardware and is specified by the value of tsNumPorts. Rows can not be created or deleted via SNMP requests." INDEX { tsPortIndex } ::= { tsPortTable 1 } tsPortEntry ::= SEQUENCE { tsPortIndex INTEGER, tsPortRcvLocalFrames Counter, tsPortForwardedFrames Counter, tsPortMostStations Counter, tsPortMaxStations Counter, tsPortSWHandledFrames Counter, tsPortLocalStations Counter, tsPortRemoteStations Counter, tsPortUnknownStaFrames Counter, tsPortResetStats INTEGER, tsPortResetTimer TimeTicks, tsPortResetAddrs INTEGER, tsPortRcvBcasts Counter, tsPortSwitchedFrames Counter, tsPortLinkState INTEGER, tsPortHashOverflows Counter, tsPortAddrAgingTime INTEGER, tsPortSwitchMode INTEGER, tsPortFixedCfg INTEGER, tsPortMode INTEGER, tsPortDuplex INTEGER, tsPortCfgLoss INTEGER, tsPortCfgLossRC INTEGER, tsPortCRCCount Counter, tsPortHPChannelFrames Counter, tsPortLPChannelFrames Counter, tsPortHPThreshold INTEGER, tsPortCfgRingSpeed INTEGER, tsPortCfgRSA INTEGER, tsPortDomain INTEGER, tsPortCfgLossThreshold INTEGER, tsPortCfgLossSamplingPeriod INTEGER, tsPortBeaconStationAddress MacAddr, tsPortBeaconNAUN MacAddr, tsPortBeaconType INTEGER, tsPortIfIndex INTEGER, tsPortOperSwitchMode INTEGER } tsPortIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The port number. Each port is identified by a unique number." ::= { tsPortEntry 1 } tsPortRcvLocalFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames received where the destination is on this port." ::= { tsPortEntry 2 } tsPortForwardedFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames received on this port and forwarded to another port or the system module for processing." ::= { tsPortEntry 3 } tsPortMostStations OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Highest number of stations ever active at any time since the last reset of the switch as seen by this port. This includes the default MAC address entries for the port." ::= { tsPortEntry 4 } tsPortMaxStations OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of stations which the port can support simultaneously." ::= { tsPortEntry 5 } tsPortSWHandledFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of Frames received on this port and delivered to the system module for processing." ::= { tsPortEntry 6 } tsPortLocalStations OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of stations on this port's address table which belong to the segment attached to this port." ::= { tsPortEntry 7 } tsPortRemoteStations OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of stations on this port's address table which belong to segments attached to other ports." ::= { tsPortEntry 8 } tsPortUnknownStaFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of unicast frames received on this port and forwarded to the system module for processing because the source or destination station address is not in the port's forwarding table." ::= { tsPortEntry 9 } tsPortResetStats OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following running(2), -- port is functioning reset(3) -- reset port counters } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this object to reset(3) causes all traffic counters for this port to be set to zero. Also the value of tsPortResetTimer is set to zero." ::= { tsPortEntry 10 } tsPortResetTimer OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Time (in 100th second ticks) since the port counters were reset." ::= { tsPortEntry 11 } tsPortResetAddrs OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following running(2), -- port is functioning reset(3) -- clear address table & reset port counters } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this object to reset(3) clears all address table entries for this port as well as setting all port traffic counters to zero and setting tsPortResetTimer to zero." ::= { tsPortEntry 12 } tsPortRcvBcasts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of Broadcast Frames received on this port without errors." ::= { tsPortEntry 13 } tsPortSwitchedFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames switched on this port" ::= { tsPortEntry 14 } tsPortLinkState OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Link state of the port." ::= { tsPortEntry 15 } tsPortHashOverflows OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of times a hash bucket was full when trying to add an entry to the port address table." ::= { tsPortEntry 16 } tsPortAddrAgingTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Port level address aging time." ::= { tsPortEntry 17 } tsPortSwitchMode OBJECT-TYPE SYNTAX INTEGER { storeandforward (1), cutthru (2), adaptive (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Configured frame switching mode for the port. When in adaptive mode the port uses the Direct Cut algorithm to place the port in either cut-thru or store-and- forward mode." ::= { tsPortEntry 18 } tsPortFixedCfg OBJECT-TYPE SYNTAX INTEGER { auto-detect (1), fixed (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Use fixed configuration or run auto detection to determine configuration. " ::= { tsPortEntry 19 } tsPortMode OBJECT-TYPE SYNTAX INTEGER { adapter (1), port (2) } ACCESS read-write STATUS mandatory DESCRIPTION "When read, this object indicates the Port Mode obtained by the auto-detect function. It is a valid read object only when TsPortFixedCfg is set to auto-detect(1) and TsPortLinkState indicates up(1). Write to this object when defining the Port Mode for a fixed configuration (TsPortFixedCfg set to fixed(2)). This object is equivalent to the dtrMac MIB object cPortProtocolCharOperationOption." ::= { tsPortEntry 20 } tsPortDuplex OBJECT-TYPE SYNTAX INTEGER { half-duplex (1), full-duplex (2), full-duplex-only (3) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is related to the dtrMac MIB objects cPortProtocolCharCurrentAccessProtocol and cPortProtocolCharAccessProtcolMask as defined in the following table: TsPortLinkState | TsPortFixedCfg | TsPortDuplex equivalent to: | | down | auto | CPortProtocolCharAccess | | ProtocolMask = X'0003' | | down | fixed | CPortProtocolCharAccess | | ProtocolMask = X'0001' or | | = X'0002' | | up | auto | cPortProtocolCharCurrent | | AccessProtocol | | up | fixed | cPortProtocolCharCurrent | | AccessProtocol." ::= { tsPortEntry 21 } tsPortCfgLoss OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of events as described in TsPortCfgLossRC after the port has completed the join process and then lost communication." ::= { tsPortEntry 22 } tsPortCfgLossRC OBJECT-TYPE SYNTAX INTEGER { other(0), wire-fault(1), beacon-auto-removal (2), force-remove-macaddr (3), connection-lost (4), adapter-check (5), close-srb (6), fdx-protocol-failure (7) } ACCESS read-only STATUS mandatory DESCRIPTION "Reason code describing the cause of configuration loss." ::= { tsPortEntry 23 } tsPortCRCCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames received with CRC error. This object is equivalent to dot5StatsLineError and to the dtrMac MIB object txiStatsLineErrorCounter." ::= { tsPortEntry 24 } tsPortHPChannelFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames sent to the high priority channel of the particular Token-Ring port." ::= { tsPortEntry 25 } tsPortLPChannelFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames sent to the low priority channel of the particular Token-Ring port." ::= { tsPortEntry 26 } tsPortHPThreshold OBJECT-TYPE SYNTAX INTEGER (0..6) ACCESS read-only STATUS mandatory DESCRIPTION "Priority level at which frames are sent to the High priority channel." DEFVAL { 4 } ::= { tsPortEntry 27 } tsPortCfgRingSpeed OBJECT-TYPE SYNTAX INTEGER { speed-16megabit (1), speed-4megabit (2), other(99) } ACCESS read-write STATUS mandatory DESCRIPTION "When read this object indicates the Port Ring Speed obtained by the RSA function. Write to this object when defining the Port Ring Speed for a fixed configuration (TsPortCfgRSA set to fixed(2)). When TsPortCfgRSA indicates fixed(2), this object is equivalent to the dtrMac MIB object cPortProtocolCharMediumRateOption and to dot5RingSpeed. Note that the syntax of these objects is different. For cPortProtocolCharMediumRateOption 1 indicates 4 Mb/s, while for TsPortCfgRingSpeed 1 indicates 16Mb/s. This object is a valid read object any time that TSPortLinkState indicates up(1)or when TsPortCfgRSA indicates fixed(2)." ::= { tsPortEntry 28 } tsPortCfgRSA OBJECT-TYPE SYNTAX INTEGER { rsa (1), fixed (2), other(99) } ACCESS read-write STATUS mandatory DESCRIPTION "User configured Ring Speed Adjust or fixed speed." ::= { tsPortEntry 29 } tsPortDomain OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Domain that the port belongs to." ::= { tsPortEntry 30 } tsPortCfgLossThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Number of configuration loss events (described in TsPortCfgLossRC) during the sample period which, if exceeded, should cause the port to be disabled. If the port is disabled by this function the port must be manually re-enabled. Valid range is 1 to 100." ::= { tsPortEntry 31 } tsPortCfgLossSamplingPeriod OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The sampling period, in minutes, for which the port monitors to see if the configuration loss threshold has been exceeeded. Valid range is 1 to 9999." ::= { tsPortEntry 32 } -- The information below is intended for the generation of SNMP -- TRAPS and should not be used to determine the health of the -- network or system tsPortBeaconStationAddress OBJECT-TYPE SYNTAX MacAddr ACCESS not-accessible STATUS mandatory DESCRIPTION "MAC address of the Station last generating a beacon MAC frame. This information is present for the generation of a trap and should not be used to represent the health of the ring." ::= { tsPortEntry 33 } tsPortBeaconNAUN OBJECT-TYPE SYNTAX MacAddr ACCESS not-accessible STATUS mandatory DESCRIPTION "MAC address of the NAUN station last generating a beacon MAC frame. This information is present for the generation of a trap and should not be used to represent the health of the ring." ::= { tsPortEntry 34 } tsPortBeaconType OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "The type of Beacon which last occurred. Values are the same as for the Beacon Type subvector and are defined as follows: X'0001' Issued by a Dual Ring Station during reconfiguration X'0002' Signal Loss X'0003' Timer TCT expired during claim token; no claim token frames recieved X'0004' Timer TCT expired during claim token; claim token frames recieved X'0005' TXI Access Protocol; Heart Beat Protocol Failure " ::= { tsPortEntry 35 } -- The information below is accessable tsPortIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The ifIndex associated with the port." ::= { tsPortEntry 36 } tsPortOperSwitchMode OBJECT-TYPE SYNTAX INTEGER { storeandforward (1), cutthru (2), adaptive (3) } ACCESS read-only STATUS mandatory DESCRIPTION "Operational frame switching mode for the port. When in adaptive mode the port uses the Direct Cut algorithm to place the port in either cut-thru or store-and- forward mode." ::= { tsPortEntry 37 } -- Optimized Port Station Table tsOptPortStaTable OBJECT-TYPE SYNTAX SEQUENCE OF tsOptPortStaEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of station addresses known at an individual port. This table is designed to reduce the number of SNMP GETNEXT requests. This is done by packing many values into an octet string. (The maximum size frame should be used to return the result.) The instance returned for a GETNEXT is the value that identifies the last 'row' in the octet string. When the table is completely retrieved with one or more GETNEXTs, duplicate entries may be present, and entries may be skipped if the table is changing while being retrieved." ::= { tsPort 2 } tsOptPortStaEntry OBJECT-TYPE SYNTAX tsOptPortStaEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Definition of the rows in the optimized port station address table. Rows can not be created or deleted via SNMP requests." INDEX { tsPortIndex, tsOptPortStaPos } ::= { tsOptPortStaTable 1 } tsOptPortStaEntry ::= SEQUENCE { tsOptPortStaPos INTEGER, tsOptPortStaVal OCTET STRING } tsOptPortStaPos OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Second index for items in the optimized port station address table." ::= { tsOptPortStaEntry 1 } tsOptPortStaVal OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "An OCTET STRING containing a multiple number of stations from a port station address table. Each entry is encoded in the following format: Station MAC address - 6 octets Location 1 - local 2 - remote - 1 octet Port of exit Mask - 4 octets Source Frame Count - 4 octets (integer in little endian) Destn Frame Count - 4 octets (integer in little endian) Source Byte Count - 4 octets (integer in little endian) Destn Byte Count - 4 octets (integer in little endian) The Port of exit mask is encoded in its raw form as stored in the switch. Octet 1 Bit position 7 6 5 4 3 2 1 0 Port Number 31 30 29 28 27 26 25 24 Octet 2 Bit position 7 6 5 4 3 2 1 0 Port Number 23 22 21 20 19 18 17 16 Octet 3 Bit position 7 6 5 4 3 2 1 0 Port Number 15 14 13 12 11 10 9 8 Octet 4 Bit position 7 6 5 4 3 2 1 0 Port Number 7 6 5 4 3 2 1 CPU " ::= { tsOptPortStaEntry 2 } -- Port Station Table tsPortStnTable OBJECT-TYPE SYNTAX SEQUENCE OF tsPortStnEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Port station table." ::= { tsPort 3 } tsPortStnEntry OBJECT-TYPE SYNTAX tsPortStnEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Definition of rows in the port table. The number of rows is determined by the hardware and is specified by the value of tsNumPorts. Rows can not be created or deleted via SNMP requests." INDEX { tsPortStnPortNum, tsPortStnAddress } ::= { tsPortStnTable 1 } tsPortStnEntry ::= SEQUENCE { tsPortStnPortNum INTEGER, tsPortStnAddress MacAddr, tsPortStnLocation INTEGER, tsPortStnSrcFrames Counter, tsPortStnSrcBytes Counter, tsPortStnDestnFrames Counter, tsPortStnDestnBytes Counter } tsPortStnPortNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Port number corresponding to this entry." ::= { tsPortStnEntry 1 } tsPortStnAddress OBJECT-TYPE SYNTAX MacAddr ACCESS read-only STATUS mandatory DESCRIPTION "Station MAC address. Equivalent to ifPhysAddr for this port." ::= { tsPortStnEntry 2 } tsPortStnLocation OBJECT-TYPE SYNTAX INTEGER { local (1), remote (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Where the station is located." ::= { tsPortStnEntry 3 } tsPortStnSrcFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames with this station as the source." ::= { tsPortStnEntry 4 } tsPortStnSrcBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of Bytes with this station as the source." ::= { tsPortStnEntry 5 } tsPortStnDestnFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames with this station as the destination." ::= { tsPortStnEntry 6 } tsPortStnDestnBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of bytes with this station as the destination." ::= { tsPortStnEntry 7 } -- ---------------------------------------------------------------------------- -- Domain Management Group -- The group consists of: -- - the domain table -- - the domain station table -- - the optimized domain station table -- ---------------------------------------------------------------------------- -- The term "Domain" used in the following section should be -- considered to be equivalent to the term "Concetrator Relay -- Function" (CRF) as defined in ISO/IEC 8802-5 Dedicated Token Ring -- Draft Standard 802.5r Annex K. -- The configuration information in the following section extends -- the information provided in the CRF configuration values of -- the dtrConc MIB. -- Domain table tsDmnTable OBJECT-TYPE SYNTAX SEQUENCE OF tsDmnEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Currently active domains on the switch." ::= { tsDmns 1 } tsDmnEntry OBJECT-TYPE SYNTAX tsDmnEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Definition of each row in the domain Table" INDEX { tsDmnIndex } ::= { tsDmnTable 1 } tsDmnEntry ::= SEQUENCE { tsDmnIndex INTEGER, tsDmnPorts OCTET STRING, tsDmnIpState INTEGER, tsDmnIpAddress IpAddress, tsDmnIpSubnetMask IpAddress, tsDmnIpDefaultGateway IpAddress, tsDmnStp INTEGER, tsDmnName DisplayString, tsDmnIfIndex INTEGER, tsDmnBaseBridgeAddr MacAddr, tsDmnNumStations INTEGER, tsDmnMostStations INTEGER } tsDmnIndex OBJECT-TYPE SYNTAX INTEGER (1..32) ACCESS read-only STATUS mandatory DESCRIPTION "Domain number for each row." ::= { tsDmnEntry 1 } tsDmnPorts OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "The set of ports that belong to this Domain. Each octet within the value of this object specifies a set of eight ports, with the first octet specifying ports 1 through 8, the second octet specifying ports 9 through 16, etc. Within each octet, the most significant bit represents the lowest numbered port, and the least significant bit represents the highest numbered port. Thus, each port of the TokenRing Switch is represented by a single bit within the value of this object. If that bit has a value of '1' then that port is included in the set of ports; the port is not included if its bit has a value of '0'. Warning: You will not receive a set- complete message as a set to this object causes the ports to reset." ::= { tsDmnEntry 2 } tsDmnIpState OBJECT-TYPE SYNTAX INTEGER { disabled (1), auto-bootp(2), always-bootp (3) } ACCESS read-write STATUS mandatory DESCRIPTION "IP configuration method for this domain." ::= { tsDmnEntry 3 } tsDmnIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IP Address of this Domain. Changes to this object will take effect immediately." ::= { tsDmnEntry 4 } tsDmnIpSubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The subnet mask for this domain. Changes to this object will take effect immediately." ::= { tsDmnEntry 5 } tsDmnIpDefaultGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IP Address of the default gateway for this Domain. Changes to this object will take effect immediately." ::= { tsDmnEntry 6 } tsDmnStp OBJECT-TYPE SYNTAX INTEGER { on (1), off (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Turn Spanning tree on or off. Changes to this object will take effect immediately. The Spanning Tree Objects themselves are in the dtrConc MIB." ::= { tsDmnEntry 7 } tsDmnName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..16)) ACCESS read-write STATUS mandatory DESCRIPTION "User assigned name for each domain. Name length limited from 0 to 16 characters by the console." ::= { tsDmnEntry 8 } tsDmnIfIndex OBJECT-TYPE SYNTAX INTEGER (1..100) ACCESS read-only STATUS mandatory DESCRIPTION "The ifIndex of the interface entry corresponding to each configured domain." ::= { tsDmnEntry 9 } tsDmnBaseBridgeAddr OBJECT-TYPE SYNTAX MacAddr ACCESS read-only STATUS mandatory DESCRIPTION "Base MAC address of this domain. Internally equivalent to dtrCRFMacAddress and to ifPhysAddress of the 'Domain' port." ::= { tsDmnEntry 10 } tsDmnNumStations OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Aggregate number of currently active stations (nodes) on all ports in the domain." ::= { tsDmnEntry 11 } tsDmnMostStations OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Highest aggregate number of stations ever active on all ports at one time, since the last reset or power cycle." ::= { tsDmnEntry 12 } -- Domains Station Table -- Information in the Domains Station Table corresponds to information -- in the dtrConc MIB Filtering Data Base. Stations learned in each -- Domain are placed into the 'Dynamic' filtering database while -- pre-defined station addresses are in the 'Static' filtering database. tsDmnStationTable OBJECT-TYPE SYNTAX SEQUENCE OF tsDmnStationEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Stations seen in each domain." ::= { tsDmns 5 } tsDmnStationEntry OBJECT-TYPE SYNTAX tsDmnStationEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Definition of each row in the domain specific station table. The object is equivalent to dtrFdbDynamicAddrTable or dtrFdbStaticAddrTable depending if the entry is learned or is a configured filter." INDEX { tsDmnIndex, tsDmnStationAddress } ::= { tsDmnStationTable 1 } tsDmnStationEntry ::= SEQUENCE { tsDmnStationDmnIndex INTEGER, tsDmnStationAddress OCTET STRING, tsDmnStationPort INTEGER, tsDmnStationTraffic OCTET STRING } tsDmnStationDmnIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Integer reference to the domain number in the domain table." ::= { tsDmnStationEntry 1 } tsDmnStationAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(6)) ACCESS read-only STATUS mandatory DESCRIPTION "The Station's MAC address." ::= { tsDmnStationEntry 2 } tsDmnStationPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The source port for the Station. The dtrConc MIB equivalents are dtrFdbDynamicAddrPortNumber and dtrFdbStaticAddrPortNumber." ::= { tsDmnStationEntry 3 } tsDmnStationTraffic OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A bit string that identifies the ports that this station has generated traffic to or from. The bits correspond to ports, with bits and ports numbered from right to left so that bit 0 represents the CPU, bit 1 represents port 1, and so forth. For example, the returned string 01 4D can be expanded to: 00000001 01001101 binary representation of object string xxxxxxx8 7654321C ports corresponding to bits This indicates ports 8, 6, 3, 2 and the CPU. The size of this string is adjusted to include all ports with traffic." ::= { tsDmnStationEntry 4 } -- Optimized Domain Station Table tsOptDmnStaTable OBJECT-TYPE SYNTAX SEQUENCE OF tsOptDmnStaEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of station addresses known at an individual port. This table is designed to reduce the number of SNMP GETNEXT requests. This is done by packing many values into an octet string. (The maximum size frame should be used to return the result.) The instance returned for a GETNEXT is the value that identifies the last 'row' in the octet string. When the table is completely retrieved with one or more GETNEXTs, duplicate entries may be present, and entries may be skipped if the table is changing while being retrieved." ::= { tsDmns 6 } tsOptDmnStaEntry OBJECT-TYPE SYNTAX tsOptDmnStaEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Definition of the rows in the optimized domain station address table. Rows can not be created or deleted via SNMP requests." INDEX { tsDmnStationDmnIndex, tsOptDmnStaPos } ::= { tsOptDmnStaTable 1 } tsOptDmnStaEntry ::= SEQUENCE { tsOptDmnStaPos INTEGER, tsOptDmnStaVal OCTET STRING } tsOptDmnStaPos OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Second index for items in the optimized port station address table." ::= { tsOptDmnStaEntry 1 } tsOptDmnStaVal OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "An OCTET STRING containing a multiple number of stations from the domain station address table. Each entry is encoded in the following format: Station MAC address - 6 octets Port of Entry - 1 octet Traffic Mask - 32 octets The traffic mask is encoded in its raw form as stored in the switch. Bit Position 7 6 5 4 3 2 1 0 Octet 1 Port Number 31 30 29 28 27 26 25 24 Octet 2 Port Number 23 22 21 20 19 18 17 16 Octet 3 Post Number 15 14 13 12 11 10 9 8 Octet 4 Port Number 7 6 5 4 3 2 1 CPU Octet 5 Port Number 63 62 61 60 59 58 57 56 Octet 6 Port Number 55 54 53 52 51 50 49 48 Octet 7 Port Number 47 46 45 44 43 42 41 40 Octet 8 Port Number 39 38 37 36 35 34 33 32 Octet 9 Port Number 95 94 93 92 91 90 89 88 Octet 10 Port Number 87 86 85 84 83 82 81 80 Octet 11 Port Number 79 78 77 76 75 74 73 72 Octet 12 Port Number 71 70 69 68 67 66 65 64 Octet 13 Port Number 127 126 125 124 123 122 121 120 Octet 14 Port Number 119 118 117 116 115 114 113 112 Octet 15 Port Number 111 110 109 108 107 106 105 104 Octet 16 Port Number 103 102 101 100 99 98 97 96 Octet 17 Port Number 159 158 157 156 155 154 153 152 Octet 18 Port Number 151 150 149 148 147 146 145 144 Octet 19 Port Number 143 142 141 140 139 138 137 136 Octet 20 Port Number 135 134 133 132 131 130 129 128 Octet 21 Port Number 191 190 189 188 187 186 185 184 Octet 22 Port Number 183 182 181 180 179 178 177 176 Octet 23 Port Number 175 174 173 172 171 170 169 168 Octet 24 Port Number 167 166 165 164 163 162 161 160 Octet 25 Port Number 223 222 221 220 219 218 217 216 Octet 26 Port Number 215 214 213 212 211 210 209 208 Octet 27 Port Number 207 206 205 204 203 202 201 200 Octet 28 Port Number 199 198 197 196 195 194 193 192 Octet 29 Port Number 255 254 253 252 251 250 249 248 Octet 30 Port Number 247 246 245 244 243 242 241 240 Octet 31 Port Number 239 238 237 236 235 234 233 232 Octet 32 Port Number 231 230 229 228 227 226 225 224" ::= { tsOptDmnStaEntry 2 } -- ---------------------------------------------------------------------------- -- Pipe Management Group -- The group consists of: -- - the Pipe table -- ---------------------------------------------------------------------------- -- Pipe Table tsPipeTable OBJECT-TYPE SYNTAX SEQUENCE OF tsPipeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The TokenPipe table." ::= { tsPipe 1 } tsPipeEntry OBJECT-TYPE SYNTAX tsPipeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Definition of each row in the TokenPipe table." INDEX { tsPipeNumber } ::= { tsPipeTable 1 } tsPipeEntry ::= SEQUENCE { tsPipeNumber INTEGER, tsPipePorts OCTET STRING } tsPipeNumber OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-only STATUS mandatory DESCRIPTION "The TokenPipe number for this row." ::= { tsPipeEntry 1 } tsPipePorts OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "The set of ports in this switch which are active in this Pipe. Each octet within the value of this object specifies a set of eight ports, with the first octet specifying ports 1 through 8, the second octet specifying ports 9 through 16 (if available), etc. Within each octet, the most significant bit represents the lowest numbered port, and the least significant bit represents the highest numbered port. Thus, each port of the LAN Switch is represented by a single bit within the value of this object. If that bit has a value of '1' then that port is included in the set of ports; the port is not included if its bit has a value of '0'." ::= { tsPipeEntry 2 } -- ---------------------------------------------------------------------------- -- Filter Configuration Group -- The group consists of: -- - the filter table -- ---------------------------------------------------------------------------- -- Filter Table tsFilterTable OBJECT-TYPE SYNTAX SEQUENCE OF tsFilterEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Filters set up in the switch." ::= { tsFilter 1 } tsFilterEntry OBJECT-TYPE SYNTAX tsFilterEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Definition of each row in the filter table." INDEX { tsFilterStationAddress, tsFilterType } ::= { tsFilterTable 1 } tsFilterEntry ::= SEQUENCE { tsFilterStationAddress MacAddr, tsFilterType INTEGER, tsFilterStatus INTEGER, tsFilterPorts OCTET STRING, tsFilterMask OCTET STRING } tsFilterStationAddress OBJECT-TYPE SYNTAX MacAddr ACCESS read-only STATUS mandatory DESCRIPTION "The MAC address in a frame to which this entry's filtering information applies." ::= { tsFilterEntry 1 } tsFilterType OBJECT-TYPE SYNTAX INTEGER { source-filter (1), destination-filter (2) } ACCESS read-only STATUS mandatory DESCRIPTION "There are two types of filters 1. source filters which act on the source address portion of a packet and 2. destination filters which act on the destination address portion of a packet." ::= { tsFilterEntry 2 } tsFilterStatus OBJECT-TYPE SYNTAX INTEGER { valid(1), invalid(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object indicates the status of this entry. valid(1) - this entry is currently in use and will remain so after the next reset of the bridge. invalid(2) - writing this value to the object removes the corresponding entry." ::= { tsFilterEntry 3 } tsFilterPorts OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "The set of ports to which this filter is applied. Each octet within the value of this object specifies a set of eight ports, with the first octet specifying ports 1 through 8, the second octet specifying ports 9 through 16, etc. Within each octet, the most significant bit represents the lowest numbered port, and the least significant bit represents the highest numbered port. Thus, each port of the TokenRing Switch is represented by a single bit within the value of this object. If that bit has a value of '1' then that port is included in the set of ports; the port is not included if its bit has a value of '0'. All frames with destination address equal to the station address corresponding to this entry and entering from any of the specified ports will be dropped. Setting this object with a MIB instance corresponding to the dotted decimal MAC address and a filter type, with the set value equal to the mask of ports you want to filter will create an entry in the table. Ex. MIB instance: 16.0.90.3.0.36.1 SNMP set value: 7F 00 00 00 This would create a filter entry with the following characteristics: MAC Address: 10 00 5A 03 00 26 (non-canonical format) Filter Type: source-filter Filter Ports: 2 3 4 5 6 7 8" ::= { tsFilterEntry 4 } tsFilterMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "The filter mask for this station. The semantics of the filter mask depend on the type of filter. For a source filter, the mask gives the ports that are allowed to receive frames from the filtered address. For a destination filter, the mask gives the ports that are forced to receive frames destined to the filtered address. Each octet within the value of this object specifies a set of eight ports, with the first octet specifying ports 1 through 8, the second octet specifying ports 9 through 16 (if available), etc. Within each octet, the most significant bit represents the lowest numbered port, and the least significant bit represents the highest numbered port. Thus, each port of the switch is represented by a single bit within the value of this object. If that bit has a value of '1' then that port is included in the set of ports; the port is not included if its bit has a value of '0'." ::= { tsFilterEntry 5 } -- ---------------------------------------------------------------------------- -- Universal Feature Card Group -- The group consists of: -- - universal feature card table -- ---------------------------------------------------------------------------- -- UFC Table tsUFCTable OBJECT-TYPE SYNTAX SEQUENCE OF tsUFCEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of the installed UFC cards in the switch. The number of entries in the table is given by tsNumberofUFCs." ::= { tsUFC 1 } tsUFCEntry OBJECT-TYPE SYNTAX tsUFCEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The objects contained in the UFC table." INDEX { tsUFCSlotNum } ::= { tsUFCTable 1 } tsUFCEntry ::= SEQUENCE { tsUFCSlotNum INTEGER, tsUFCNumPhysIfs INTEGER, tsUFCManufacturer DisplayString, tsUFCType OCTET STRING, tsUFCTypeDesc DisplayString, tsUFCHwVer DisplayString, tsUFCFwVer DisplayString, tsUFCStatus INTEGER, tsUFCReset INTEGER } tsUFCSlotNum OBJECT-TYPE SYNTAX INTEGER (1..32) ACCESS read-only STATUS mandatory DESCRIPTION "The number of the slot in which the UFC is installed." ::= { tsUFCEntry 1 } tsUFCNumPhysIfs OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The total number of physical network interfaces on the UFC. This count does not include the interface _OF_ the card or any logical interfaces which be _ON_ the card." ::= { tsUFCEntry 2 } tsUFCManufacturer OBJECT-TYPE SYNTAX DisplayString (SIZE (16)) ACCESS read-only STATUS mandatory DESCRIPTION "Firmware manufacturer." ::= { tsUFCEntry 3 } tsUFCType OBJECT-TYPE SYNTAX OCTET STRING(SIZE(2)) ACCESS read-only STATUS mandatory DESCRIPTION "The code representing what type of UFC is present. UFC codes are assigned by UFC manufacturer." ::= { tsUFCEntry 4 } tsUFCTypeDesc OBJECT-TYPE SYNTAX DisplayString(SIZE(0..127)) ACCESS read-only STATUS mandatory DESCRIPTION "A text string describing what type of UFC is present." ::= { tsUFCEntry 5 } tsUFCHwVer OBJECT-TYPE SYNTAX DisplayString(SIZE(0..64)) ACCESS read-only STATUS mandatory DESCRIPTION "The hardware version in the form major.minor." ::= { tsUFCEntry 6 } tsUFCFwVer OBJECT-TYPE SYNTAX DisplayString(SIZE(0..64)) ACCESS read-only STATUS mandatory DESCRIPTION "The firmware version in the form major.minor." ::= { tsUFCEntry 7 } tsUFCStatus OBJECT-TYPE SYNTAX INTEGER { up(1), -- UFC is operational down(2), -- UFC is down or reseting other(3) -- UFC is in an unknown state } ACCESS read-only STATUS mandatory DESCRIPTION "The operational status of the UFC." ::= { tsUFCEntry 8 } tsUFCReset OBJECT-TYPE SYNTAX INTEGER { running(1), -- UFC is running reset(2) -- reset the UFC } ACCESS read-write STATUS mandatory DESCRIPTION "The object is used to reset a UFC. Setting this to reset causes the UFC to be re-initialized." ::= { tsUFCEntry 9 } -- ---------------------------------------------------------------------------- -- SNMP Information Group -- The group consists of: -- - SNMP information table -- ---------------------------------------------------------------------------- -- SNMP Information Table tsSnmpInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF tsSnmpInfoEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of the SNMP MIBs which are supported by the switch." ::= { tsSnmpInfo 1 } tsSnmpInfoEntry OBJECT-TYPE SYNTAX tsSnmpInfoEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The objects contained in the SNMP Info Table." INDEX { tsSnmpInfoSlotNum, tsSnmpInfoEntryNum } ::= { tsSnmpInfoTable 1 } tsSnmpInfoEntry ::= SEQUENCE { tsSnmpInfoSlotNum INTEGER, tsSnmpInfoEntryNum INTEGER, tsSnmpInfoObjectId OBJECT IDENTIFIER, tsSnmpInfoDescr DisplayString, tsSnmpInfoIpAddress IpAddress } tsSnmpInfoSlotNum OBJECT-TYPE SYNTAX INTEGER (1..32) ACCESS read-only STATUS mandatory DESCRIPTION "The slot number associated with this entry. Slot number zero represents the base switch. All other slot numbers repesent the external slot number of the switch." ::= { tsSnmpInfoEntry 1 } tsSnmpInfoEntryNum OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The entry number for this slot. Each slot may support zero to n MIBs or MIB groups." ::= { tsSnmpInfoEntry 2 } tsSnmpInfoObjectId OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS optional DESCRIPTION "The anchor point for a MIB or MIB group. This OID provides an easy and unambiguous means for determining which MIBs or MIB groups which may are supported by the slot." ::= { tsSnmpInfoEntry 3 } tsSnmpInfoDescr OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS optional DESCRIPTION "A short description of the MIB or MIB group. This object provides an quick text interpretation of the MIB or MIB group." ::= { tsSnmpInfoEntry 4 } tsSnmpInfoIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS optional DESCRIPTION "The IP address to direct the SNMP requests for this entry's MIB or MIB group." ::= { tsSnmpInfoEntry 5 } END