PPM-IGNIS-V1TRAPS-MIB DEFINITIONS ::= BEGIN IMPORTS TRAP-TYPE FROM RFC-1215 ppm FROM PPM-ORG-MIB trapsModuleType, trapsSlotIndex, trapsSeverity FROM PPM-IGNIS-MIB; -- ---------------------------------------------------------- -- -- This MIB defines the SNMP (v1) traps which can be -- sent by the ViaLiteHD (IGNIS) Web & SNMP Controller Module HRC-1 and HRC-3 -- This MIB must be loaded alongside the PPM-ORG-MIB and PPM-IGNIS-MIB, and should be used -- with product specific MIB revisions no older than 11/10/2017. -- This MIB file supersedes the PPM-TRAPS-MIB file, both MIBs should not be used in conjunction. -- REVISION "201710111300Z" -- DESCRIPTION "1.1 - Updated to add the HRC-3 specific traps" -- REVISION "201701101300Z" -- DESCRIPTION "1.0 - SNMP v1 Traps moved to separate MIB file (taken from PPM-IGNIS-MIB)" -- Pulse Power & Measurement Ltd. reserves the right to make chamges in specifications -- and all other information contained in this document without prior notice. -- Pulse Power & Measurement Ltd. grants vendors, end-users, and other interested parties -- a non-exclusive license to use this specification in connection with the management of -- Pulse Power & Measurement products. -- ---------------------------------------------------------- -- majorAlarm TRAP-TYPE ENTERPRISE ppm VARIABLES { trapsModuleType,trapsSlotIndex,trapsSeverity } DESCRIPTION "Major alarm." ::= 10 majorClear TRAP-TYPE ENTERPRISE ppm VARIABLES { trapsModuleType,trapsSlotIndex,trapsSeverity } DESCRIPTION "Major alarm is cleared." ::= 11 minorAlarm TRAP-TYPE ENTERPRISE ppm VARIABLES { trapsModuleType,trapsSlotIndex,trapsSeverity } DESCRIPTION "Minor alarm." ::= 12 minorCleared TRAP-TYPE ENTERPRISE ppm VARIABLES { trapsModuleType,trapsSlotIndex,trapsSeverity } DESCRIPTION "Minor alarm is cleared." ::= 13 agcAlarm TRAP-TYPE ENTERPRISE ppm VARIABLES { trapsModuleType,trapsSlotIndex,trapsSeverity } DESCRIPTION "AGC alarm." ::= 14 agcCleared TRAP-TYPE ENTERPRISE ppm VARIABLES { trapsModuleType,trapsSlotIndex,trapsSeverity } DESCRIPTION "AGC alarm is cleared." ::= 15 vccAlarm TRAP-TYPE ENTERPRISE ppm VARIABLES { trapsModuleType,trapsSlotIndex,trapsSeverity } DESCRIPTION "VCC alarm." ::= 16 vccCleared TRAP-TYPE ENTERPRISE ppm VARIABLES { trapsModuleType,trapsSlotIndex,trapsSeverity } DESCRIPTION "VCC alarm is cleared." ::= 17 rllAlarm TRAP-TYPE ENTERPRISE ppm VARIABLES { trapsModuleType,trapsSlotIndex,trapsSeverity } DESCRIPTION "RLL alarm." ::= 18 rllCleared TRAP-TYPE ENTERPRISE ppm VARIABLES { trapsModuleType,trapsSlotIndex,trapsSeverity } DESCRIPTION "RLL alarm is cleared." ::= 19 rflAlarm TRAP-TYPE ENTERPRISE ppm VARIABLES { trapsModuleType,trapsSlotIndex,trapsSeverity } DESCRIPTION "RFL alarm." ::= 21 rflCleared TRAP-TYPE ENTERPRISE ppm VARIABLES { trapsModuleType,trapsSlotIndex,trapsSeverity } DESCRIPTION "RFL alarm is cleared." ::= 22 rfGainAlarm TRAP-TYPE ENTERPRISE ppm VARIABLES { trapsModuleType,trapsSlotIndex,trapsSeverity } DESCRIPTION "RF gain alarm." ::= 23 rfGainCleared TRAP-TYPE ENTERPRISE ppm VARIABLES { trapsModuleType,trapsSlotIndex,trapsSeverity } DESCRIPTION "RF gain alarm is cleared." ::= 24 laserAlarm TRAP-TYPE ENTERPRISE ppm VARIABLES { trapsModuleType,trapsSlotIndex,trapsSeverity } DESCRIPTION "Laser alarm." ::= 25 laserCleared TRAP-TYPE ENTERPRISE ppm VARIABLES { trapsModuleType,trapsSlotIndex,trapsSeverity } DESCRIPTION "Laser alarm is cleared." ::= 26 biasAlarm TRAP-TYPE ENTERPRISE ppm VARIABLES { trapsModuleType,trapsSlotIndex,trapsSeverity } DESCRIPTION "Bias alarm." ::= 27 biasCleared TRAP-TYPE ENTERPRISE ppm VARIABLES { trapsModuleType,trapsSlotIndex,trapsSeverity } DESCRIPTION "Bias alarm is cleared." ::= 28 powerAlarm TRAP-TYPE ENTERPRISE ppm VARIABLES { trapsModuleType,trapsSlotIndex,trapsSeverity } DESCRIPTION "Power level alarm." ::= 29 powerCleared TRAP-TYPE ENTERPRISE ppm VARIABLES { trapsModuleType,trapsSlotIndex,trapsSeverity } DESCRIPTION "Power level alarm is cleared." ::= 30 feedIAlarm TRAP-TYPE ENTERPRISE ppm VARIABLES { trapsModuleType,trapsSlotIndex,trapsSeverity } DESCRIPTION "Feed I alarm." ::= 31 feedICleared TRAP-TYPE ENTERPRISE ppm VARIABLES { trapsModuleType,trapsSlotIndex,trapsSeverity } DESCRIPTION "Feed I alarm is cleared." ::= 32 feedVAlarm TRAP-TYPE ENTERPRISE ppm VARIABLES { trapsModuleType,trapsSlotIndex,trapsSeverity } DESCRIPTION "Feed V alarm." ::= 33 feedVCleared TRAP-TYPE ENTERPRISE ppm VARIABLES { trapsModuleType,trapsSlotIndex,trapsSeverity } DESCRIPTION "Feed V alarm is cleared." ::= 34 txTempAlarm TRAP-TYPE ENTERPRISE ppm VARIABLES { trapsModuleType,trapsSlotIndex,trapsSeverity } DESCRIPTION "Transmitter over temperature alarm." ::= 35 txTempCleared TRAP-TYPE ENTERPRISE ppm VARIABLES { trapsModuleType,trapsSlotIndex,trapsSeverity } DESCRIPTION "Transmitter over temperature alarm is cleared." ::= 36 lnbOverloadAlarm TRAP-TYPE ENTERPRISE ppm VARIABLES { trapsModuleType,trapsSlotIndex,trapsSeverity } DESCRIPTION "LNB overload alarm." ::= 37 lnbOverloadCleared TRAP-TYPE ENTERPRISE ppm VARIABLES { trapsModuleType,trapsSlotIndex,trapsSeverity } DESCRIPTION "LNB overload alarm is cleared." ::= 38 lnbTempAlarm TRAP-TYPE ENTERPRISE ppm VARIABLES { trapsModuleType,trapsSlotIndex,trapsSeverity } DESCRIPTION "LNB over temperature alarm." ::= 39 lnbTempCleared TRAP-TYPE ENTERPRISE ppm VARIABLES { trapsModuleType,trapsSlotIndex,trapsSeverity } DESCRIPTION "LNB over temperature alarm is cleared." ::= 40 sysVoltageAlarm TRAP-TYPE ENTERPRISE ppm VARIABLES { trapsModuleType,trapsSlotIndex,trapsSeverity } DESCRIPTION "System supply voltage alarm." ::= 50 sysVoltageCleared TRAP-TYPE ENTERPRISE ppm VARIABLES { trapsModuleType,trapsSlotIndex,trapsSeverity } DESCRIPTION "System supply voltage alarm is cleared." ::= 51 sysTempAlarm TRAP-TYPE ENTERPRISE ppm VARIABLES { trapsModuleType,trapsSlotIndex,trapsSeverity } DESCRIPTION "System temperature alarm." ::= 52 sysTempCleared TRAP-TYPE ENTERPRISE ppm VARIABLES { trapsModuleType,trapsSlotIndex,trapsSeverity } DESCRIPTION "System temperature alarm is cleared." ::= 53 sysPowerUp TRAP-TYPE ENTERPRISE ppm VARIABLES { trapsModuleType,trapsSlotIndex,trapsSeverity } DESCRIPTION "System was powered up or reset." ::= 54 sysEventHistoryCleared TRAP-TYPE ENTERPRISE ppm VARIABLES { trapsModuleType,trapsSlotIndex,trapsSeverity } DESCRIPTION "System event log was cleared." ::= 55 cardInserted TRAP-TYPE ENTERPRISE ppm VARIABLES { trapsModuleType,trapsSlotIndex,trapsSeverity } DESCRIPTION "Card inserted." ::= 60 cardRemoved TRAP-TYPE ENTERPRISE ppm VARIABLES { trapsModuleType,trapsSlotIndex,trapsSeverity } DESCRIPTION "Card removed or failure." ::= 61 psuNormal TRAP-TYPE ENTERPRISE ppm VARIABLES { trapsModuleType,trapsSlotIndex,trapsSeverity } DESCRIPTION "Power supply normal." ::= 62 psuAlarm TRAP-TYPE ENTERPRISE ppm VARIABLES { trapsModuleType,trapsSlotIndex,trapsSeverity } DESCRIPTION "Power supply alarm." ::= 63 ethNoLinkAlarm TRAP-TYPE ENTERPRISE ppm VARIABLES { trapsModuleType,trapsSlotIndex,trapsSeverity } DESCRIPTION "The Ethernet Mediaconverter has no ethernt link." ::= 64 ethLink TRAP-TYPE ENTERPRISE ppm VARIABLES { trapsModuleType,trapsSlotIndex,trapsSeverity } DESCRIPTION "An Ethernet link has been established by the Ethernet Mediaconverter." ::= 65 moduleInMaintenaceMode TRAP-TYPE ENTERPRISE ppm VARIABLES { trapsModuleType,trapsSlotIndex,trapsSeverity } DESCRIPTION "This trap is sent when a module in the ViaLiteHD enclosure is put into maintenance mode. Modules in maintenance mode will not generate any further traps until taken out of maintenance mode. The SlotsTable SNMP objects are still updated as normal whilst in maintenance mode" ::= 66 moduleNotInMaintenaceMode TRAP-TYPE ENTERPRISE ppm VARIABLES { trapsModuleType,trapsSlotIndex,trapsSeverity } DESCRIPTION "This trap is sent when a module in the ViaLiteHD enclosure is taken out of maintenance mode." ::= 67 doorOpen TRAP-TYPE ENTERPRISE ppm VARIABLES { trapsModuleType,trapsSlotIndex,trapsSeverity } DESCRIPTION "SATCOM6 Door open indicator" ::= 68 doorClosed TRAP-TYPE ENTERPRISE ppm VARIABLES { trapsModuleType,trapsSlotIndex,trapsSeverity } DESCRIPTION "SATCOM6 Door open indicator" ::= 69 END