------------------------------------------------------------ -- Emerson Energy Systems (EES) -- Power MIB ------------------------------------------------------------ EES-POWER-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32, Counter32, enterprises FROM SNMPv2-SMI TEXTUAL-CONVENTION, DisplayString, DateAndTime FROM SNMPv2-TC; powerMIB MODULE-IDENTITY LAST-UPDATED "202012101427Z" ORGANIZATION " Vertiv Tech Co. Ltd" CONTACT-INFO " Vertiv Sweden AB 120 07 Stockholm Sweden" DESCRIPTION " Vertiv Tech Co. Ltd. Power MIB, revision E." ::= { enterprises 6302 2 1 } ------------------------------------------------------------ -- Node definitions ------------------------------------------------------------ ees OBJECT IDENTIFIER ::= { enterprises 6302 } global OBJECT IDENTIFIER ::= { ees 2 } ------------------------------------------------------------ -- Textual conventions ------------------------------------------------------------ Status ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION " This integer value represents the operational or administrative status of the system. Also used as alarm severity. Depending on situation there may be limits on allowed values. Operational values: (1) unknown - status has not yet been defined (2) normal - there are no activated alarms (3) warning - OA, lowest level of 'abnormal' status (4) minor - A3 (5) major - MA (6) critical - CA, highest level of 'abnormal' status Administrative values: (7) unmanaged (8) restricted (9) testing (10) disabled" SYNTAX INTEGER { unknown(1), normal(2), warning(3), minor(4), major(5), critical(6), unmanaged(7), restricted(8), testing(9), disabled(10) } StatusChange ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION " Indicates 'activated' (1) or 'deactivated' (2) alarm events." SYNTAX INTEGER { activated(1), deactivated(2) } ------------------------------------------------------------ -- 1.1 Identification of the plant { powerMIB 1 } ------------------------------------------------------------ ident OBJECT IDENTIFIER ::= { powerMIB 1 } identManufacturer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " The name of the equipment manufacturer." ::= { ident 1 } identModel OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " The manufacturers model designation of the power system." ::= { ident 2 } identControllerFirmwareVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " The firmware (software) version of the controller." ::= { ident 3 } identName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " The name of the power plant. This object should be set by the administrator." ::= { ident 4 } identSNMPCfgVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " The snmp cfg version" ::= { ident 5 } identControllerSerialNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " The serial number of this controller" ::= { ident 6 } ------------------------------------------------------------ -- 1.2 System values { powerMIB 2 } ------------------------------------------------------------ system OBJECT IDENTIFIER ::= { powerMIB 2 } systemStatus OBJECT-TYPE SYNTAX Status MAX-ACCESS read-only STATUS current DESCRIPTION " Status of the complete plant (highest alarm). One of (1) unknown - status has not yet been defined (2) normal - there are no activated alarms (3) warning - OA, lowest level of 'abnormal' status (4) minor - A3 (5) major - MA (6) critical - CA, highest level of 'abnormal' status (7) unmanaged (8) restricted (9) testing (10) disabled" ::= { system 1 } systemVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " System voltage, stored as mV, including positive or negative sign. The integer 2147483647 represents invalid value." ::= { system 2 } systemCurrent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " System current, stored as mA, including positive or negative sign. The integer 2147483647 represents invalid value." ::= { system 3 } systemUsedCapacity OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " Used capacity, stored as % of the total capacity. The integer 2147483647 represents invalid value." ::= { system 4 } -- ------------------------------------------------------------------------ -- 1.2.5. Battery group -- ------------------------------------------------------------------------ psBattery OBJECT IDENTIFIER ::= { system 5 } psBatteryVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Battery voltage, stored as mV, including positive or negative sign. The integer 2147483647 represents invalid value." ::= { psBattery 1 } psTotalBatteryCurrent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Battery current, stored as mA, including positive or negative sign. The integer 2147483647 represents invalid value." ::= { psBattery 2 } psLowestBatteryCapacity OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " Calculated capacity, stored as % of the total capacity. The integer 2147483647 represents invalid value." ::= { psBattery 3 } psBatteryNominalCapacity OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " nominal installed capacity, stored as mAh. The integer 2147483647 represents invalid value." ::= { psBattery 4 } psBatteryTable OBJECT-TYPE SYNTAX SEQUENCE OF PSBatteryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Battery Table." ::= { psBattery 5 } psBatteryEntry OBJECT-TYPE SYNTAX PSBatteryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Battery Measurement Table Entry." INDEX { psBatteryIndex } ::= { psBatteryTable 1 } PSBatteryEntry ::= SEQUENCE { psBatteryIndex Integer32, psBatteryCurrent Integer32, psBatteryName DisplayString, psBatteryRatedCapacity Integer32, psBatteryCapacity Integer32, psBatteryCapacityPercent Integer32 } psBatteryIndex OBJECT-TYPE SYNTAX Integer32(1..16777215) MAX-ACCESS read-only STATUS current DESCRIPTION "Automatically generated index object." ::= { psBatteryEntry 1 } psBatteryCurrent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Battery current in mA." ::= { psBatteryEntry 2 } psBatteryName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Battery shunt name." ::= { psBatteryEntry 3 } psBatteryRatedCapacity OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Battery reted capacity." ::= { psBatteryEntry 4 } psBatteryCapacity OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Battery capacity in Ah." ::= { psBatteryEntry 5 } psBatteryCapacityPercent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Battery capacity in percent." ::= { psBatteryEntry 6 } numberOfBatteryStrings OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of battery strings, including SMDUBat and MainboardBat. The integer 2147483647 represents invalid value." ::= { psBattery 6 } temperatureOfBattery OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " Temperature of battery. The integer 2147483647 represents invalid value." ::= { psBattery 7 } maxCurrentOfCharging OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Maximun battery charging current. The integer 2147483647 represents invalid value." ::= { psBattery 8 } chargingVoltage OBJECT IDENTIFIER ::= { psBattery 9 } floatVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Float charging voltage. The integer 2147483647 represents invalid value." ::= { chargingVoltage 1 } boostVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Boost charging voltage. The integer 2147483647 represents invalid value." ::= { chargingVoltage 2 } highBatteryTemperature OBJECT IDENTIFIER ::= { psBattery 10 } psHighBatteryTemperature OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " High battery temperature. The integer 2147483647 represents invalid value." ::= { highBatteryTemperature 1 } psVeryHighBatteryTemperature OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Very high battery temperature. The integer 2147483647 represents invalid value." ::= { highBatteryTemperature 2 } temperatureCompensationCoefficient OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Temperature compensation coefficient. The integer 2147483647 represents invalid value." ::= { psBattery 11 } temperatureCompensation OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " Temperature compensation . The integer 2147483647 represents invalid value." ::= { psBattery 12 } batt1RemainingCapacity OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Remain capacity of battery, stored as % of the total capacity. The integer 2147483647 represents invalid value." ::= { psBattery 13 } batt1ShuntFullScaleCurrent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Battery 1 Shunt Full Scale Current in mA. The integer 2147483647 represents invalid value." ::= { psBattery 14 } batt1ShuntFullScaleVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Battery 1 Shunt Full Scale Voltage in thousandths of mV. The integer 2147483647 represents invalid value." ::= { psBattery 15 } psBatteryCurrentLimit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Battery charge current limit stored as thousandths of C10" ::= { psBattery 16 } psBatteryType OBJECT-TYPE SYNTAX INTEGER (1..10) MAX-ACCESS read-write STATUS current DESCRIPTION " Battery Type number" ::= { psBattery 17 } psResetBatteryCapacity OBJECT-TYPE SYNTAX INTEGER { yes(1) } MAX-ACCESS read-write STATUS current DESCRIPTION " Reset Battery Capacity, Yes(1)" ::= { psBattery 18 } psBatteryOverCurrentLimit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Battery over current limit stored as thousandths of C10" ::= { psBattery 19 } psBatteryAccumDischargeNarada OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " Narada Battery's Cumulated Discharge." ::= { psBattery 20 } psBatterySOHNarada OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " Narada Battery's SOH." ::= { psBattery 21 } psBatterySOHIncell OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " Incell Battery's SOH." ::= { psBattery 22 } psBatterySOHVision OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " Vision Battery's SOH." ::= { psBattery 23 } psBatterySOHNokia OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " Nokia Battery's SOH." ::= { psBattery 24 } -- ------------------------------------------------------------------------ -- 1.2.6. the psInput group -- ------------------------------------------------------------------------ psInput OBJECT IDENTIFIER ::= { system 6 } psInputLineAVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The AC line A voltage, stored as mV. The integer 2147483647 represents invalid value." ::= { psInput 1 } psInputLineBVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The AC line B voltage, stored as mV. The integer 2147483647 represents invalid value." ::= { psInput 2 } psInputLineCVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The AC line C voltage, stored as mV. The integer 2147483647 represents invalid value." ::= { psInput 3 } psInputPhaseACurrent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The AC Phase A current, stored as mA. The integer 2147483647 represents invalid value." ::= { psInput 4 } psInputPhaseBCurrent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The AC Phase B current, stored as mA. The integer 2147483647 represents invalid value." ::= { psInput 5 } psInputPhaseCCurrent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The AC Phase C current, stored as mA. The integer 2147483647 represents invalid value." ::= { psInput 6 } psInputPowerCP OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Rectifier Total Input Power(CP) in thousandths of watts." ::= { psInput 7 } psInputPowerDG OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Rectifier Total Input Power(DG) in thousandths of watts." ::= { psInput 8 } -- ------------------------------------------------------------------------ -- 1.2.7. the temperatures -- ------------------------------------------------------------------------ psTemperature OBJECT IDENTIFIER ::= { system 7 } psTemperature1 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The first route temperature, stored as 0.001 Celsius degree. The integer 2147483647 represents invalid value." ::= { psTemperature 1 } psTemperature2 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The second route temperature, stored as 0.001 Celsius degree. The integer 2147483647 represents invalid value.." ::= { psTemperature 2 } psTemperatureTable OBJECT-TYPE SYNTAX SEQUENCE OF PSTemperatureEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Temperature Measurement Table." ::= { psTemperature 3 } psTemperatureEntry OBJECT-TYPE SYNTAX PSTemperatureEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Temperature Measurement Table Entry." INDEX { psTemperatureIndex } ::= { psTemperatureTable 1 } PSTemperatureEntry ::= SEQUENCE { psTemperatureIndex Integer32, psTemperatureMeasurement Integer32, psTemperatureName DisplayString, psTemperatureType INTEGER, psTemperatureAlarmStatus INTEGER } psTemperatureIndex OBJECT-TYPE SYNTAX Integer32(1..71) MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature Probe Number " ::= { psTemperatureEntry 1 } psTemperatureMeasurement OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature Value In 0.001 Celsius Degree." ::= { psTemperatureEntry 2 } psTemperatureName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Configured Temperature Probe Name." ::= { psTemperatureEntry 3 } psTemperatureType OBJECT-TYPE SYNTAX INTEGER { none(0), ambient(1), battery(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature Probe Type " ::= { psTemperatureEntry 4 } psTemperatureAlarmStatus OBJECT-TYPE SYNTAX INTEGER { high(0), low(1), fail(2), none(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature Probe Alarm Status " ::= { psTemperatureEntry 5 } psStatusCommunication OBJECT-TYPE SYNTAX INTEGER { unknown(1), normal(2), interrupt(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of communication with the Power System. interrupt(3) indicates some errors occurred between Power System and agent." ::= { system 8 } psStatusBatteryMode OBJECT-TYPE SYNTAX INTEGER { unknown(1), floatCharging(2), shortTest(3), bcForTest(4), manualTesting(5), planTesting(6), acFailTesting(7), acFail(8), manualBC(9), autoBC(10), cyclicBC(11), masterBC(12), masterBT(13) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of battery modes, FloatCharging(2), ShortTest(3), BoostChargingForTest(4), ManualTesting(5), PlanTesting(6), ACFailTesting(7), ACFail(8), ManualBoostCharging(9), AutoBoostCharging(10), CyclicBoostCharging(11), MasterBoostCharging(12), MasterBateryTesting(13)." ::= { system 9 } -- ------------------------------------------------------------------------ -- 1.2.10. the SM series group(only get number of SM series) -- ------------------------------------------------------------------------ psSMNumber OBJECT IDENTIFIER ::= { system 10 } psSMACNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of SM AC module." ::= { psSMNumber 1 } psSMBATNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of SM BAT module." ::= { psSMNumber 2 } psSMIONumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of SM IO module." ::= { psSMNumber 3 } -- ------------------------------------------------------------------------ -- 1.2.11. Rectifier group -- ------------------------------------------------------------------------ psRectifier OBJECT IDENTIFIER ::= { system 11 } numberOfInstalledRectifiers OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " number of rectifiers, stored as integer. The integer 2147483647 represents invalid value." ::= { psRectifier 1 } numberOfRectifiersCommunicating OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " number of rectifiers communicating, stored as integer. The integer 2147483647 represents invalid value." ::= { psRectifier 2 } rectifiersUsedCapacity OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " Used capacity, stored as % of the total capacity. The integer 2147483647 represents invalid value." ::= { psRectifier 3 } psRectifierTable OBJECT-TYPE SYNTAX SEQUENCE OF PSRectifierEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Table holding information about indivual rectifiers." ::= { psRectifier 4 } psRectifierEntry OBJECT-TYPE SYNTAX PSRectifierEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " An entry (conceptual row) in the rectifierInfoTable." INDEX { psRectifierIndex } ::= { psRectifierTable 1 } PSRectifierEntry ::= SEQUENCE { psRectifierIndex Integer32, psRectifierProductNumber DisplayString, psRectifierHWVersion DisplayString, psRectifierSWVersion DisplayString, psRectifierSerialNumber DisplayString, psRectifierCurrent Integer32, psRectifierIdent DisplayString, psRectifierFail StatusChange, psRectifierTemperature Integer32 } psRectifierIndex OBJECT-TYPE SYNTAX Integer32(1..16777215) MAX-ACCESS read-only STATUS current DESCRIPTION "Automatically generated index object." ::= { psRectifierEntry 1 } psRectifierProductNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Rectifier Product Number." ::= { psRectifierEntry 2} psRectifierHWVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Rectifier Hardware Revision." ::= { psRectifierEntry 3} psRectifierSWVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Rectifier Software Revision." ::= { psRectifierEntry 4} psRectifierSerialNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Rectifier Serial Number." ::= { psRectifierEntry 5} psRectifierCurrent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Rectifier Current." ::= { psRectifierEntry 6} psRectifierIdent OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Rectifier physical location identifier." ::= { psRectifierEntry 7} psRectifierFail OBJECT-TYPE SYNTAX StatusChange MAX-ACCESS read-only STATUS current DESCRIPTION " The type of alarm change. One of (1) activated (2) deactivated" ::= { psRectifierEntry 8} psRectifierTemperature OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Rectifier Temperature." ::= { psRectifierEntry 9} psPowerOfRectifiers OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " Total power of rectifiers. The integer 2147483647 represents invalid value." ::= { psRectifier 5 } psOverOutputVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " Rectifier output over voltage protection point. The integer 2147483647 represents invalid value." ::= { psRectifier 7 } psVeryOverOutputVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " Rectifier output very over voltage protection point. The integer 2147483647 represents invalid value." ::= { psRectifier 8 } psSoftStartStatus OBJECT-TYPE SYNTAX INTEGER{ enable(1), disabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " Soft-start functuin status. The integer 2147483647 represents invalid value." ::= { psRectifier 9 } psSoftStartTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "SoftStart Time, stored as Sec. Value range: 8~128." ::= { psRectifier 10 } psACEnergyOfRectifiers OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " Total AC energy of rectifiers. The integer 2147483647 represents invalid value." ::= { psRectifier 11 } psDCEnergyOfRectifiers OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " Total DC energy of rectifiers. The integer 2147483647 represents invalid value." ::= { psRectifier 12 } psRectifierAllONOFF OBJECT-TYPE SYNTAX INTEGER{ Open(0), Close(1) } MAX-ACCESS read-write STATUS current DESCRIPTION " ON OFF of all rectifiers. The integer 2147483647 represents invalid value." ::= { psRectifier 13 } -- ------------------------------------------------------------------------ -- 1.2.12. the Distribution -- ------------------------------------------------------------------------ psDistribution OBJECT IDENTIFIER ::= { system 12 } psTotalLoadCurrent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " Total Load current, stored as mA. The integer 2147483647 represents invalid value." ::= { psDistribution 1 } psDistributionLoadTable OBJECT-TYPE SYNTAX SEQUENCE OF PSDistributionLoadEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Distribution Table." ::= { psDistribution 2 } psDistributionLoadEntry OBJECT-TYPE SYNTAX PSDistributionLoadEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Distribution Measurement Table Entry." INDEX { psDistributionLoadIndex } ::= { psDistributionLoadTable 1 } PSDistributionLoadEntry ::= SEQUENCE { psDistributionLoadIndex Integer32, psDistributionLoadCurrent Integer32, psDistributionLoadName DisplayString } psDistributionLoadIndex OBJECT-TYPE SYNTAX Integer32(1..268386303) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Automatically generated index object." ::= { psDistributionLoadEntry 1 } psDistributionLoadCurrent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Distribution current in mA." ::= { psDistributionLoadEntry 2 } psDistributionLoadName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Distribution name." ::= { psDistributionLoadEntry 3 } psDistributionGeneralTable OBJECT-TYPE SYNTAX SEQUENCE OF PSDistributionGeneralEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Distribution Table." ::= { psDistribution 3 } psDistributionGeneralEntry OBJECT-TYPE SYNTAX PSDistributionGeneralEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Distribution Measurement Table Entry." INDEX { psDistributionGeneralIndex } ::= { psDistributionGeneralTable 1 } PSDistributionGeneralEntry ::= SEQUENCE { psDistributionGeneralIndex Integer32, psDistributionGeneralCurrent Integer32, psDistributionGeneralName DisplayString } psDistributionGeneralIndex OBJECT-TYPE SYNTAX Integer32(1..268386303) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Automatically generated index object." ::= { psDistributionGeneralEntry 1 } psDistributionGeneralCurrent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Distribution current in mA." ::= { psDistributionGeneralEntry 2 } psDistributionGeneralName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Distribution name." ::= { psDistributionGeneralEntry 3 } -- ------------------------------------------------------------------------ -- 1.2.13. Converter group -- ------------------------------------------------------------------------ psConverter OBJECT IDENTIFIER ::= { system 13 } numberOfInstalledConverters OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " number of converters, stored as integer. The integer 2147483647 represents invalid value." ::= { psConverter 1 } numberOfConvertersCommunicating OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " number of converters communicating, stored as integer. The integer 2147483647 represents invalid value." ::= { psConverter 2 } convertersUsedCapacity OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " Used capacity, stored as % of the total capacity. The integer 2147483647 represents invalid value." ::= { psConverter 3 } psConverterVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " Converter voltage in mV. The integer 2147483647 represents invalid value." ::= { psConverter 4 } psTotalConverterCurrent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " Total Converter current in mA. The integer 2147483647 represents invalid value." ::= { psConverter 5 } psConverterTable OBJECT-TYPE SYNTAX SEQUENCE OF PSConverterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Table holding information about indivual converters." ::= { psConverter 6 } psConverterEntry OBJECT-TYPE SYNTAX PSConverterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " An entry (conceptual row) in the ConverterInfoTable." INDEX { psConverterIndex } ::= { psConverterTable 1 } PSConverterEntry ::= SEQUENCE { psConverterIndex Integer32, psConverterProductNumber DisplayString, psConverterHWVersion DisplayString, psConverterSWVersion DisplayString, psConverterSerialNumber DisplayString, psConverterCurrent Integer32, psConverterIdent DisplayString, psConverterFail StatusChange } psConverterIndex OBJECT-TYPE SYNTAX Integer32(1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Automatically generated index object." ::= { psConverterEntry 1 } psConverterProductNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Converter Product Number." ::= { psConverterEntry 2} psConverterHWVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Converter Hardware Revision." ::= { psConverterEntry 3} psConverterSWVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Converter Software Revision." ::= { psConverterEntry 4} psConverterSerialNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Converter Serial Number." ::= { psConverterEntry 5} psConverterCurrent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Converter Current." ::= { psConverterEntry 6} psConverterIdent OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Converter physical location identifier." ::= { psConverterEntry 7} psConverterFail OBJECT-TYPE SYNTAX StatusChange MAX-ACCESS read-only STATUS current DESCRIPTION " The type of alarm change. One of (1) activated (2) deactivated" ::= { psConverterEntry 8} -- ------------------------------------------------------------------------ -- 1.2.14. Control group -- ------------------------------------------------------------------------ psControl OBJECT IDENTIFIER ::= { system 14 } controlBatteryTest OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Control battery test, start(1), stop(0)." ::= { psControl 1 } controlRelay8 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Control relay8, close(1), open(0)." ::= { psControl 2 } controlRelay7 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Control relay7, close(1), open(0)." ::= { psControl 3 } controlRelay6 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Control relay6, close(1), open(0)." ::= { psControl 4 } controlRelayTest OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Control Relay test, auto(2), manual(1), disabled(0)." ::= { psControl 5 } -- ------------------------------------------------------------------------ -- 1.2.15. EquipmentSignalTable -- ------------------------------------------------------------------------ psEquipmentSignalTable OBJECT-TYPE SYNTAX SEQUENCE OF EquipmentSignalTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Table of indexed equipment signal values." ::= { system 15 } equipmentSignalTableEntry OBJECT-TYPE SYNTAX EquipmentSignalTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " An entry (conceptual row) in the psEquipment Signal Table." INDEX { psEquipmentSignalTableEntryIndex } ::= { psEquipmentSignalTable 1 } EquipmentSignalTableEntry ::= SEQUENCE { psEquipmentSignalTableEntryIndex Integer32, psEquipmentSignalValue Integer32 } psEquipmentSignalTableEntryIndex OBJECT-TYPE SYNTAX Integer32(1..268386303) MAX-ACCESS read-only STATUS current DESCRIPTION " The unique sequence number of this equipment signal." ::= { equipmentSignalTableEntry 1 } psEquipmentSignalValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " Indexed equipment signal value." ::= { equipmentSignalTableEntry 2 } ambientTemperature OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " AmbientTemperature. The integer 2147483647 represents invalid value." ::= { system 16 } autoManualMode OBJECT-TYPE SYNTAX INTEGER{ auto(1), manual(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " Auto/Manual Mode of system. The integer 2147483647 represents invalid value." ::= { system 17 } -- ------------------------------------------------------------------------ -- 1.2.18. LVDVoltage -- ------------------------------------------------------------------------ psLVDVoltage OBJECT IDENTIFIER ::= { system 18 } psLVD1DisconnectVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "LVD1 Disconnect voltage, stored as mV. The integer 2147483647 represents invalid value." ::= { psLVDVoltage 1 } psLVD2DisconnectVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "LVD2 Disconnect voltage, stored as mV. The integer 2147483647 represents invalid value." ::= { psLVDVoltage 2 } psLVD1ReconnectVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "LVD1 Reconnect voltage, stored as mV. The integer 2147483647 represents invalid value." ::= { psLVDVoltage 3 } psLVD2ReconnectVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "LVD2 Reconnect voltage, stored as mV. The integer 2147483647 represents invalid value." ::= { psLVDVoltage 4 } smdu1LVD1DisconnectVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "SMDU1 LVD1 Disconnect voltage, stored as mV. The integer 2147483647 represents invalid value." ::= { psLVDVoltage 5 } smdu1LVD2DisconnectVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "SMDU1 LVD2 Disconnect voltage, stored as mV. The integer 2147483647 represents invalid value." ::= { psLVDVoltage 6 } smdu1LVD1ReconnectVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "SMDU1 LVD1 Reconnect voltage, stored as mV. The integer 2147483647 represents invalid value." ::= { psLVDVoltage 7 } smdu1LVD2ReconnectVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "SMDU1 LVD2 Reconnect voltage, stored as mV. The integer 2147483647 represents invalid value." ::= { psLVDVoltage 8 } -- ------------------------------------------------------------------------ -- 1.2.19. DCLowVoltage -- ------------------------------------------------------------------------ psDCLowVoltage OBJECT IDENTIFIER ::= { system 19 } psDCLowAlarmVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "DC low voltage, stored as mV. The integer 2147483647 represents invalid value." ::= { psDCLowVoltage 1 } psDCVeryLowAlarmVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "DC very low voltage, stored as mV. The integer 2147483647 represents invalid value." ::= { psDCLowVoltage 2 } -- ------------------------------------------------------------------------ -- 1.2.20. ACLowVoltage -- ------------------------------------------------------------------------ acLowVoltage OBJECT IDENTIFIER ::= { system 20 } psACLowAlarmVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "AC low voltage, stored as V. The integer 2147483647 represents invalid value." ::= { acLowVoltage 1 } psACVeryLowAlarmVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "AC very low voltage, stored as V. The integer 2147483647 represents invalid value." ::= { acLowVoltage 2 } -- ------------------------------------------------------------------------ -- 1.2.21. SMDUHCurrentTable -- ------------------------------------------------------------------------ psSMDUHCurrent OBJECT IDENTIFIER ::= { system 21 } numberOfInstalledSMDUH OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " number of SMDHU units, stored as integer. The integer 2147483647 represents invalid value." ::= { psSMDUHCurrent 1 } psSMDUH1Voltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " SMDUH1 Voltage in mV." ::= { psSMDUHCurrent 2 } psSMDUH2Voltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " SMDUH2 Voltage in mV." ::= { psSMDUHCurrent 3 } psSMDUH3Voltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " SMDUH3 Voltage in mV." ::= { psSMDUHCurrent 4 } psSMDUH4Voltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " SMDUH4 Voltage in mV." ::= { psSMDUHCurrent 5 } psSMDUH5Voltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " SMDUH5 Voltage in mV." ::= { psSMDUHCurrent 6 } psSMDUH6Voltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " SMDUH6 Voltage in mV." ::= { psSMDUHCurrent 7 } psSMDUH7Voltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " SMDUH7 Voltage in mV." ::= { psSMDUHCurrent 8 } psSMDUH8Voltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " SMDUH8 Voltage in mV." ::= { psSMDUHCurrent 9 } psSMDUHCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF PSSMDUHCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Table holding information about SMDUH currents." ::= { psSMDUHCurrent 10 } psSMDUHCurrentEntry OBJECT-TYPE SYNTAX PSSMDUHCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " An entry (conceptual row) in the SMDUHTable." INDEX { psSMDUHCurrentIndex } ::= { psSMDUHCurrentTable 1 } PSSMDUHCurrentEntry ::= SEQUENCE { psSMDUHCurrentIndex Integer32, psSMDUHCurrent1 Integer32, psSMDUHCurrent2 Integer32, psSMDUHCurrent3 Integer32, psSMDUHCurrent4 Integer32, psSMDUHCurrent5 Integer32, psSMDUHCurrent6 Integer32, psSMDUHCurrent7 Integer32, psSMDUHCurrent8 Integer32, psSMDUHCurrent9 Integer32, psSMDUHCurrent10 Integer32, psSMDUHCurrent11 Integer32, psSMDUHCurrent12 Integer32, psSMDUHCurrent13 Integer32, psSMDUHCurrent14 Integer32, psSMDUHCurrent15 Integer32, psSMDUHCurrent16 Integer32, psSMDUHCurrent17 Integer32, psSMDUHCurrent18 Integer32, psSMDUHCurrent19 Integer32, psSMDUHCurrent20 Integer32 } psSMDUHCurrentIndex OBJECT-TYPE SYNTAX Integer32(1..64) MAX-ACCESS read-only STATUS current DESCRIPTION "Automatically generated index object." ::= { psSMDUHCurrentEntry 1 } psSMDUHCurrent1 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Current 1 in mA." ::= { psSMDUHCurrentEntry 2} psSMDUHCurrent2 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Current 2 in mA." ::= { psSMDUHCurrentEntry 3} psSMDUHCurrent3 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Current 3 in mA." ::= { psSMDUHCurrentEntry 4} psSMDUHCurrent4 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Current 4 in mA." ::= { psSMDUHCurrentEntry 5} psSMDUHCurrent5 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Current 5 in mA." ::= { psSMDUHCurrentEntry 6} psSMDUHCurrent6 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Current 6 in mA." ::= { psSMDUHCurrentEntry 7} psSMDUHCurrent7 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Current 7 in mA." ::= { psSMDUHCurrentEntry 8} psSMDUHCurrent8 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Current 8 in mA." ::= { psSMDUHCurrentEntry 9} psSMDUHCurrent9 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Current 9 in mA." ::= { psSMDUHCurrentEntry 10} psSMDUHCurrent10 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Current 10 in mA." ::= { psSMDUHCurrentEntry 11} psSMDUHCurrent11 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Current 11 in mA." ::= { psSMDUHCurrentEntry 12} psSMDUHCurrent12 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Current 12 in mA." ::= { psSMDUHCurrentEntry 13} psSMDUHCurrent13 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Current 13 in mA." ::= { psSMDUHCurrentEntry 14} psSMDUHCurrent14 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Current 14 in mA." ::= { psSMDUHCurrentEntry 15} psSMDUHCurrent15 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Current 15 in mA." ::= { psSMDUHCurrentEntry 16} psSMDUHCurrent16 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Current 16 in mA." ::= { psSMDUHCurrentEntry 17} psSMDUHCurrent17 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Current 17 in mA." ::= { psSMDUHCurrentEntry 18} psSMDUHCurrent18 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Current 18 in mA." ::= { psSMDUHCurrentEntry 19} psSMDUHCurrent19 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Current 19 in mA." ::= { psSMDUHCurrentEntry 20} psSMDUHCurrent20 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Current 20 in mA." ::= { psSMDUHCurrentEntry 21} -- ------------------------------------------------------------------------ -- 1.2.22. SMDUHPowerTable -- ------------------------------------------------------------------------ psSMDUHPower OBJECT IDENTIFIER ::= { system 22 } psSMDUHPowerTable OBJECT-TYPE SYNTAX SEQUENCE OF PSSMDUHPowerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Table holding information about SMDUH power." ::= { psSMDUHPower 1 } psSMDUHPowerEntry OBJECT-TYPE SYNTAX PSSMDUHPowerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " An entry (conceptual row) in the SMDUHPowerTable." INDEX { psSMDUHPowerIndex } ::= { psSMDUHPowerTable 1 } PSSMDUHPowerEntry ::= SEQUENCE { psSMDUHPowerIndex Integer32, psSMDUHPower1 Integer32, psSMDUHPower2 Integer32, psSMDUHPower3 Integer32, psSMDUHPower4 Integer32, psSMDUHPower5 Integer32, psSMDUHPower6 Integer32, psSMDUHPower7 Integer32, psSMDUHPower8 Integer32, psSMDUHPower9 Integer32, psSMDUHPower10 Integer32, psSMDUHPower11 Integer32, psSMDUHPower12 Integer32, psSMDUHPower13 Integer32, psSMDUHPower14 Integer32, psSMDUHPower15 Integer32, psSMDUHPower16 Integer32, psSMDUHPower17 Integer32, psSMDUHPower18 Integer32, psSMDUHPower19 Integer32, psSMDUHPower20 Integer32 } psSMDUHPowerIndex OBJECT-TYPE SYNTAX Integer32(1..64) MAX-ACCESS read-only STATUS current DESCRIPTION "Automatically generated index object." ::= { psSMDUHPowerEntry 1 } psSMDUHPower1 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Power 1 in thousandths of kW." ::= { psSMDUHPowerEntry 2} psSMDUHPower2 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Power 2." ::= { psSMDUHPowerEntry 3} psSMDUHPower3 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Power 3." ::= { psSMDUHPowerEntry 4} psSMDUHPower4 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Power 4." ::= { psSMDUHPowerEntry 5} psSMDUHPower5 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Power 5." ::= { psSMDUHPowerEntry 6} psSMDUHPower6 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Power 6." ::= { psSMDUHPowerEntry 7} psSMDUHPower7 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Power 7." ::= { psSMDUHPowerEntry 8} psSMDUHPower8 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Power 8." ::= { psSMDUHPowerEntry 9} psSMDUHPower9 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Power 9." ::= { psSMDUHPowerEntry 10} psSMDUHPower10 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Power 10." ::= { psSMDUHPowerEntry 11} psSMDUHPower11 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Power 11." ::= { psSMDUHPowerEntry 12} psSMDUHPower12 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Power 12." ::= { psSMDUHPowerEntry 13} psSMDUHPower13 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Power 13." ::= { psSMDUHPowerEntry 14} psSMDUHPower14 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Power 14." ::= { psSMDUHPowerEntry 15} psSMDUHPower15 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Power 15." ::= { psSMDUHPowerEntry 16} psSMDUHPower16 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Power 16." ::= { psSMDUHPowerEntry 17} psSMDUHPower17 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Power 17." ::= { psSMDUHPowerEntry 18} psSMDUHPower18 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Power 18." ::= { psSMDUHPowerEntry 19} psSMDUHPower19 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Power 19." ::= { psSMDUHPowerEntry 20} psSMDUHPower20 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Power 20." ::= { psSMDUHPowerEntry 21} -- ------------------------------------------------------------------------ -- 1.2.23. SMDUHEnergyTable -- ------------------------------------------------------------------------ psSMDUHEnergy OBJECT IDENTIFIER ::= { system 23 } psSMDUHEnergyTable OBJECT-TYPE SYNTAX SEQUENCE OF PSSMDUHEnergyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Table holding information about SMDUH energy counters." ::= { psSMDUHEnergy 1 } psSMDUHEnergyEntry OBJECT-TYPE SYNTAX PSSMDUHEnergyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " An entry (conceptual row) in the SMDUHEnergyTable." INDEX { psSMDUHEnergyIndex } ::= { psSMDUHEnergyTable 1 } PSSMDUHEnergyEntry ::= SEQUENCE { psSMDUHEnergyIndex Integer32, psSMDUHTotalEnergy1 Integer32, psSMDUHTotalEnergy2 Integer32, psSMDUHTotalEnergy3 Integer32, psSMDUHTotalEnergy4 Integer32, psSMDUHTotalEnergy5 Integer32, psSMDUHTotalEnergy6 Integer32, psSMDUHTotalEnergy7 Integer32, psSMDUHTotalEnergy8 Integer32, psSMDUHTotalEnergy9 Integer32, psSMDUHTotalEnergy10 Integer32, psSMDUHTotalEnergy11 Integer32, psSMDUHTotalEnergy12 Integer32, psSMDUHTotalEnergy13 Integer32, psSMDUHTotalEnergy14 Integer32, psSMDUHTotalEnergy15 Integer32, psSMDUHTotalEnergy16 Integer32, psSMDUHTotalEnergy17 Integer32, psSMDUHTotalEnergy18 Integer32, psSMDUHTotalEnergy19 Integer32, psSMDUHTotalEnergy20 Integer32 } psSMDUHEnergyIndex OBJECT-TYPE SYNTAX Integer32(1..64) MAX-ACCESS read-only STATUS current DESCRIPTION "Automatically generated index object." ::= { psSMDUHEnergyEntry 1 } psSMDUHTotalEnergy1 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Total Energy 1." ::= { psSMDUHEnergyEntry 2} psSMDUHTotalEnergy2 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Total Energy 2." ::= { psSMDUHEnergyEntry 3} psSMDUHTotalEnergy3 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Total Energy 3." ::= { psSMDUHEnergyEntry 4} psSMDUHTotalEnergy4 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Total Energy 4." ::= { psSMDUHEnergyEntry 5} psSMDUHTotalEnergy5 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Total Energy 5." ::= { psSMDUHEnergyEntry 6} psSMDUHTotalEnergy6 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Total Energy 6." ::= { psSMDUHEnergyEntry 7} psSMDUHTotalEnergy7 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Total Energy 7." ::= { psSMDUHEnergyEntry 8} psSMDUHTotalEnergy8 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Total Energy 8." ::= { psSMDUHEnergyEntry 9} psSMDUHTotalEnergy9 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Total Energy 9." ::= { psSMDUHEnergyEntry 10} psSMDUHTotalEnergy10 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Total Energy 10." ::= { psSMDUHEnergyEntry 11} psSMDUHTotalEnergy11 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Total Energy 11." ::= { psSMDUHEnergyEntry 12} psSMDUHTotalEnergy12 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Total Energy 12." ::= { psSMDUHEnergyEntry 13} psSMDUHTotalEnergy13 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Total Energy 13." ::= { psSMDUHEnergyEntry 14} psSMDUHTotalEnergy14 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Total Energy 14." ::= { psSMDUHEnergyEntry 15} psSMDUHTotalEnergy15 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Total Energy 15." ::= { psSMDUHEnergyEntry 16} psSMDUHTotalEnergy16 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Total Energy 16." ::= { psSMDUHEnergyEntry 17} psSMDUHTotalEnergy17 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Total Energy 17." ::= { psSMDUHEnergyEntry 18} psSMDUHTotalEnergy18 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Total Energy 18." ::= { psSMDUHEnergyEntry 19} psSMDUHTotalEnergy19 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Total Energy 19." ::= { psSMDUHEnergyEntry 20} psSMDUHTotalEnergy20 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDUH Total Energy 20." ::= { psSMDUHEnergyEntry 21} -- ------------------------------------------------------------------------ -- 1.2.24. SMDUTable -- ------------------------------------------------------------------------ psSMDU OBJECT IDENTIFIER ::= { system 24 } psSMDUTable OBJECT-TYPE SYNTAX SEQUENCE OF PSSMDUEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Table holding information about SMDU." ::= { psSMDU 1 } psSMDUEntry OBJECT-TYPE SYNTAX PSSMDUEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " An entry (conceptual row) in the SMDU Table." INDEX { psSMDUIndex } ::= { psSMDUTable 1 } PSSMDUEntry ::= SEQUENCE { psSMDUIndex Integer32, psSMDULoad1Power Integer32, psSMDULoad2Power Integer32, psSMDULoad3Power Integer32, psSMDULoad4Power Integer32, psSMDULoad5Power Integer32, psSMDUShunt1FullScaleCurrent Integer32, psSMDUShunt1FullScaleVoltage Integer32, psSMDUShunt2FullScaleCurrent Integer32, psSMDUShunt2FullScaleVoltage Integer32, psSMDUShunt3FullScaleCurrent Integer32, psSMDUShunt3FullScaleVoltage Integer32, psSMDUShunt4FullScaleCurrent Integer32, psSMDUShunt4FullScaleVoltage Integer32, psSMDUShunt5FullScaleCurrent Integer32, psSMDUShunt5FullScaleVoltage Integer32 } psSMDUIndex OBJECT-TYPE SYNTAX Integer32(1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "Automatically generated index object." ::= { psSMDUEntry 1 } psSMDULoad1Power OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDU Load1 Power in thousandths of kW" ::= { psSMDUEntry 2 } psSMDULoad2Power OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDU Load2 Power in thousandths of kW" ::= { psSMDUEntry 3 } psSMDULoad3Power OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDU Load3 Power in thousandths of kW" ::= { psSMDUEntry 4 } psSMDULoad4Power OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDU Load4 Power in thousandths of kW" ::= { psSMDUEntry 5 } psSMDULoad5Power OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SMDU Load5 Power in thousandths of kW" ::= { psSMDUEntry 6 } psSMDUShunt1FullScaleCurrent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "SMDU Shunt1 Full Scale Current in mA." ::= { psSMDUEntry 7 } psSMDUShunt1FullScaleVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "SMDU Shunt1 Full Scale Voltage in thousandths of mV." ::= { psSMDUEntry 8 } psSMDUShunt2FullScaleCurrent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "SMDU Shunt2 Full Scale Current in mA." ::= { psSMDUEntry 9 } psSMDUShunt2FullScaleVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "SMDU Shunt2 Full Scale Voltage in thousandths of mV." ::= { psSMDUEntry 10 } psSMDUShunt3FullScaleCurrent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "SMDU Shunt3 Full Scale Current in mA." ::= { psSMDUEntry 11 } psSMDUShunt3FullScaleVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "SMDU Shunt3 Full Scale Voltage in thousandths of mV." ::= { psSMDUEntry 12 } psSMDUShunt4FullScaleCurrent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "SMDU Shunt4 Full Scale Current in mA." ::= { psSMDUEntry 13 } psSMDUShunt4FullScaleVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "SMDU Shunt4 Full Scale Voltage in thousandths of mV." ::= { psSMDUEntry 14 } psSMDUShunt5FullScaleCurrent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "SMDU Shunt5 Full Scale Current in mA." ::= { psSMDUEntry 15 } psSMDUShunt5FullScaleVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "SMDU Shunt5 Full Scale Voltage in thousandths of mV." ::= { psSMDUEntry 16 } -- ------------------------------------------------------------------------ -- 1.2.25. Solar group -- ------------------------------------------------------------------------ psSolar OBJECT IDENTIFIER ::= { system 25 } numberOfInstalledSolar OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " number of Solar converters, stored as integer. The integer 2147483647 represents invalid value." ::= { psSolar 1 } numberOfSolarCommunicating OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " number of Solar converters communicating, stored as integer. The integer 2147483647 represents invalid value." ::= { psSolar 2 } solarsUsedCapacity OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " Used capacity, stored as % of the total capacity. The integer 2147483647 represents invalid value." ::= { psSolar 3 } psSolarTotalCurrent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " Solar Converter Total output current in mA. The integer 2147483647 represents invalid value." ::= { psSolar 4 } psSolarTotalPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Solar Converter Total Output Power in W * 1000." ::= { psSolar 5 } psSolarTotalInputCurrent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " Solar Converter Total input current in mA. The integer 2147483647 represents invalid value." ::= { psSolar 6 } psSolarTotalInputPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Solar Converter Total input Power in kW * 1000." ::= { psSolar 7 } psSolarMode OBJECT-TYPE SYNTAX INTEGER { disabled(0), rect-solar(1), solar(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " Solar mode, Disabled(0), RECT-SOLAR(1), Solar(2)" ::= { psSolar 8 } psSolarRunningWay OBJECT-TYPE SYNTAX INTEGER { rect-first(0), mppt-first(1) } MAX-ACCESS read-write STATUS current DESCRIPTION " Solar mode, Disabled(0), RECT-SOLAR(1), Solar(2)" ::= { psSolar 9 } -- ------------------------------------------------------------------------ -- 1.2.26. Setting group -- ------------------------------------------------------------------------ psSetting OBJECT IDENTIFIER ::= { system 26 } settingSolarFloatVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Solar Float voltage stored as mV" ::= { psSetting 1 } settingSolarEQChargeVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Solar Equalize voltage stored as mV" ::= { psSetting 2 } settingRectifierFloatVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Rectifier Float voltage stored as mV" ::= { psSetting 3 } settingRectifierEQChargeVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Rectifier Equalize voltage stored as mV" ::= { psSetting 4 } settingRectifierWalkInEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION " Rectifier walk-in Enable, Disabled(0), Active(1)" ::= { psSetting 5 } settingRectifierWalkInTime OBJECT-TYPE SYNTAX INTEGER (8..128) MAX-ACCESS read-write STATUS current DESCRIPTION " Rectifier walk-in time in seconds." ::= { psSetting 6 } settingRectifierCurrentLimitEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION " Rectifier Current Limit Enable, Disabled(0), Active(1)" ::= { psSetting 7 } settingRectifierCurrentLimit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Rectifier current limit stored as mA" ::= { psSetting 8 } settingRectifierInputCurrentLimit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Rectifier input current limit stored as mA" ::= { psSetting 9 } settingGeneratorPowerLimitEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION " Diesel Generator Power Limit Enable, Disabled(0), Active(1)" ::= { psSetting 10 } settingGeneratorPowerLimitPoint OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Diesel Generator Power Limit point in percent * 1000." ::= { psSetting 11 } settingGeneratorStartVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Diesel Generator Start voltage stored as mV" ::= { psSetting 12 } settingGeneratorStopVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Diesel Generator Stop voltage stored as mV" ::= { psSetting 13 } settingHybridMode OBJECT-TYPE SYNTAX INTEGER { disabled(0), single-diesel(1), dieselandAC(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " Solar mode, Disabled(0), RECT-SOLAR(1), Solar(2)" ::= { psSetting 14 } settingGeneratorRelay OBJECT-TYPE SYNTAX INTEGER { none(0), relayOutput1(1), relayOutput2(2), relayOutput3(3), relayOutput4(4), relayOutput5(5), relayOutput6(6), relayOutput7(7), relayOutput8(8) } MAX-ACCESS read-write STATUS current DESCRIPTION " Diesel Generator Relay, None(0), Relay Output 1(1), Relay Output 2(2), Relay Output 3(3), Relay Output 4(4), Relay Output 5(5), Relay Output 6(6), Relay Output 7(7), Relay Output 8(8)" ::= { psSetting 15 } -- ------------------------------------------------------------------------ -- 1.2.27. CabinetTable -- ------------------------------------------------------------------------ psCabinet OBJECT IDENTIFIER ::= { system 27 } psCabinetTable OBJECT-TYPE SYNTAX SEQUENCE OF PSCabinetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Table holding information about Cabinet." ::= { psCabinet 1 } psCabinetEntry OBJECT-TYPE SYNTAX PSCabinetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " An entry (conceptual row) in the Cabinet Table." INDEX { psCabinetIndex } ::= { psCabinetTable 1 } PSCabinetEntry ::= SEQUENCE { psCabinetIndex Integer32, psCabinetTotalCurrent Integer32, psCabinetTotalPower Integer32, psCabinetTotalEnergy Integer32, psCabinetAlarmStatus INTEGER } psCabinetIndex OBJECT-TYPE SYNTAX Integer32(1..20) MAX-ACCESS read-only STATUS current DESCRIPTION "Automatically generated index object." ::= { psCabinetEntry 1 } psCabinetTotalCurrent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cabinet Total Current in mA" ::= { psCabinetEntry 2 } psCabinetTotalPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cabinet Total Power in thousandths of W" ::= { psCabinetEntry 3 } psCabinetTotalEnergy OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cabinet Total Energy in thousandths of KWh" ::= { psCabinetEntry 4 } psCabinetAlarmStatus OBJECT-TYPE SYNTAX INTEGER { notAlarmed(0), alarmLevel1(1), alarmLevel2(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Cabinet Alarm Status" ::= { psCabinetEntry 5 } ------------------------------------------------------------ -- Alarm trap counter { powerMIB 3 } ------------------------------------------------------------ alarmLastTrapNo OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " The sequence number of last submitted alarm trap, also last row in alarmTrapTable." ::= { powerMIB 3 } ------------------------------------------------------------ -- Active Alarm table { powerMIB 4 } ------------------------------------------------------------ alarmActiveAlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF ActiveAlarmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Table holding information about the currently active alarms." ::= { powerMIB 4 } activeAlarmEntry OBJECT-TYPE SYNTAX ActiveAlarmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " An entry (conceptual row) in the alarmTrapTable." INDEX { alarmIndex } ::= { alarmActiveAlarmTable 1 } ActiveAlarmEntry ::= SEQUENCE { alarmIndex Counter32, alarmTime DateAndTime, alarmStatusChange StatusChange, alarmSeverity Status, alarmDescription DisplayString, alarmType Integer32 } alarmIndex OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " The unique sequence number of this alarm trap." ::= { activeAlarmEntry 1 } alarmTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION " Date and time when event occured (local time), including timezone if supported by controller." ::= { activeAlarmEntry 2 } alarmStatusChange OBJECT-TYPE SYNTAX StatusChange MAX-ACCESS read-only STATUS current DESCRIPTION " The type of alarm change. One of (1) activated (2) deactivated" ::= { activeAlarmEntry 3 } alarmSeverity OBJECT-TYPE SYNTAX Status MAX-ACCESS read-only STATUS current DESCRIPTION " The severity of the alarm. One of (3) warning - OA, lowest level of alarm severity (4) minor - A3 (5) major - MA (6) critical - CA, highest level of alarm severity" ::= { activeAlarmEntry 4 } alarmDescription OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " Free-text description of alarm." ::= { activeAlarmEntry 5 } alarmType OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " Alarm type, i.e. an integer specifying the type of alarm." ::= { activeAlarmEntry 6 } ------------------------------------------------------------ -- Events/traps { powerMIB 5 } ------------------------------------------------------------ powerEvents OBJECT IDENTIFIER ::= { powerMIB 5 } alarmTrap NOTIFICATION-TYPE OBJECTS { alarmIndex, alarmTime, alarmStatusChange, alarmSeverity, alarmDescription, alarmType } STATUS current DESCRIPTION " An alarm trap is sent when an alarm occurs (activated) or returns to normal state (deactivated). Alarm traps are logged in alarmTrapTable. Variables in this trap: * alarmIndex - The unique sequence number of this alarm trap. * alarmTime - Date and time when event occured (local time), including timezone if supported by controller. * alarmStatusChange - (1) activated or (2) deactivated. * alarmSeverity - Integer describing the severity of the alarm. * alarmDescription - Free-text description of alarm. * alarmType - Integer indicating type of alarm." ::= { powerEvents 1 } alarmActiveTrap NOTIFICATION-TYPE OBJECTS { alarmTime, alarmSeverity, alarmDescription, alarmType } STATUS current DESCRIPTION " An alarm trap is sent when an alarm occurs (activated) Variables in this trap * alarmTime - Date and time when event occured (local time), including timezone if supported by controller. * alarmSeverity - Integer describing the severity of the alarm. * alarmDescription - Free-text description of alarm. * alarmType - Integer indicating type of alarm." ::= { powerEvents 2 } alarmCeaseTrap NOTIFICATION-TYPE OBJECTS { alarmTime, alarmSeverity, alarmDescription, alarmType } STATUS current DESCRIPTION " An alarm trap is sent when an alarm returns to normal state (clear, deactivated). Variables in this trap: * alarmTime - Date and time when event occured (local time), including timezone if supported by controller. * alarmSeverity - Integer describing the severity of the alarm. * alarmDescription - Free-text description of alarm. * alarmType - Integer indicating type of alarm." ::= { powerEvents 3 } ------------------------------------------------------------ -- End of MIB definitions ------------------------------------------------------------ END