-- MIB-File-Header-Block -- -- STRATACOM Switch MIB -- RELEASE: 8.1 -- STRATACOM-MIB --FORCE-INCLUDE --FORCE-INCLUDE --FORCE-INCLUDE --FORCE-INCLUDE --FORCE-INCLUDE -- all functions can use %n for object name and -- %t for object type, %p for parent name, -- %d for name of default-bearing node and %% for % --DEFAULT test-function it-exists --DEFAULT set-function null-set-proc --DEFAULT get-function get-%n --DEFAULT next-function std-next --DEFAULT view-mask PUBLIC-VIEW --DEFAULT cookie (char *)NULL --DEFAULT locator 0 DEFINITIONS ::= BEGIN -- This MIB has not been officially released to the N.I.C. IMPORTS enterprises, IpAddress, Counter, TimeTicks FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215; DisplayString ::= OCTET STRING stratacom OBJECT IDENTIFIER ::= { enterprises 351 } strmErrors OBJECT IDENTIFIER ::= { stratacom 910} snmpAgents OBJECT IDENTIFIER ::= { stratacom 100} strmSwitchMIB OBJECT IDENTIFIER ::= { snmpAgents 4 } switchInterfaces OBJECT IDENTIFIER ::= { strmSwitchMIB 1 } switchServiceObjects OBJECT IDENTIFIER ::= { strmSwitchMIB 2 } switchConnection OBJECT IDENTIFIER ::= { strmSwitchMIB 3 } switchShelf OBJECT IDENTIFIER ::= { strmSwitchMIB 4 } frServiceObjects OBJECT IDENTIFIER ::= { switchServiceObjects 1 } atmServiceObjects OBJECT IDENTIFIER ::= { switchServiceObjects 2 } voiceServiceObjects OBJECT IDENTIFIER ::= { switchServiceObjects 3 } trunkServiceObjects OBJECT IDENTIFIER ::= { switchServiceObjects 4 } shelfCnfgObjects OBJECT IDENTIFIER ::= { switchShelf 1 } -- The following describes the MIB variables for the switchIFTable. -- This table provides the manager a view of the interfaces available -- on the requested switch. The table provides the physical interface -- available as well as the service provided by that interface. -- -- *************************************************************** -- This table will be developed in future phases of this project. -- *************************************************************** -- --switchIFTable OBJECT-TYPE -- SYNTAX SEQUENCE OF SlotPortEntry -- ACCESS not-accessible -- STATUS mandatory -- DESCRIPTION "A list of slots and their associated ports" -- DEFAULT test-function test-switchiftable -- DEFAULT next-function next-switchiftable -- DEFAULT get-function get-switchiftable-%t -- ::= { switchInterfaces 1 } -- --switchIFEntry OBJECT-TYPE -- SYNTAX SlotPortEntry -- ACCESS not-accessible -- STATUS mandatory -- DESCRIPTION "A slot-port entry" -- INDEX { switchIFSlotIndex , switchIFPortIndex } -- ::= { switchIFTable 1 } -- --SwitchIFEntry ::= -- SEQUENCE { -- switchIFSlotIndex INTEGER, -- switchIFPortIndex INTEGER, -- switchIFType INTEGER, -- switchIFService INTEGER -- } -- The following describes the MIB variables for the switchIFTable. switchIfTable OBJECT-TYPE SYNTAX SEQUENCE OF SwitchIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of ports and subports, and their interfaces" --DEFAULT test-function test-switchiftable --DEFAULT next-function next-switchiftable --DEFAULT get-function get-switchiftable-%t ::= { switchInterfaces 1 } switchIfEntry OBJECT-TYPE SYNTAX SwitchIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A slot-port-subport entry" INDEX { switchIfIndex } ::= { switchIfTable 1 } SwitchIfEntry ::= SEQUENCE { switchIfIndex INTEGER, switchIfSlot INTEGER, switchIfPort INTEGER, switchIfSubPort INTEGER, switchIfMediaType INTEGER, switchIfService INTEGER, switchIfAdmStatus INTEGER, switchIfOperStatus INTEGER, switchIfPhysPort INTEGER, switchIfPartiId INTEGER, switchIfCtrlerId INTEGER } switchIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The interface number is the index for the switchIfTable, as well as the switchMedia tables and the Trunk Service tables. The switchIFIndex will be an INTEGER with the value related to the slot, port, and subport as follows: switchIFIndex = (slot x 1000000)+(port x 10000)+(subport);" ::= { switchIfEntry 1 } switchIfSlot OBJECT-TYPE -- SYNTAX INTEGER (1..32) SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The slot number." ::= { switchIfEntry 2 } switchIfPort OBJECT-TYPE -- SYNTAX INTEGER (1..32) SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number." ::= { switchIfEntry 3 } switchIfSubPort OBJECT-TYPE -- SYNTAX INTEGER (0..32) SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The subport number, used to identify virtual trunks." ::= { switchIfEntry 4 } switchIfMediaType OBJECT-TYPE SYNTAX INTEGER { other(1), ds1(18), serialPort(22), ds3(30), sonet(39) } ACCESS read-only STATUS mandatory DESCRIPTION "The type of interface. This object is normally used to provide information about a media layer, such as ds1, ds3, or sonet." ::= { switchIfEntry 5 } switchIfService OBJECT-TYPE SYNTAX INTEGER { other(1), frameRelay(2), atmAccessPort(3), voiceData(4), fpRoutingTrk(5), atmRoutingTrk(6), atmAxisIntfTrk(7), atmIPXAFIntfTrk(8), atmFdrIntfTrk(9), atmAPSIntfTrk(10), imaRoutingTrunk(11), physicalMedia(12), atmVsiIntfTrk(13), atmParIntfTrk(14) } ACCESS read-write STATUS mandatory DESCRIPTION "User requested service for logical interface table row. atmVsiIntfTrk is only available for BXM resource on BPX. IPX cannot support the service." ::= { switchIfEntry 6 } switchIfAdmStatus OBJECT-TYPE SYNTAX INTEGER { up(1), down(2), added(6), deleted(7) } ACCESS read-write STATUS mandatory DESCRIPTION "User requested state for logical interface table row. A user may up, down, add, or delete an interface. The set-request PDU should contain values for both switchIFService and switchAdmStatus. A logical row can be created in the switchIfTable by combining an appropriate switchIFService and switchAdmStatus up(1). switchIFService and switchAdmStatus. A logical row can be deleted from the switchIfTable by combining an appropriate switchIFService and switchAdmStatus down(2). The values for added(6) and deleted(7) can be used only with a valid Trunk switchIfService (5..8)." ::= { switchIfEntry 7 } switchIfOperStatus OBJECT-TYPE SYNTAX INTEGER { up(1), down(2), testing(3), unknown(4), dormant(5), added(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The current state for logical interface table row." ::= { switchIfEntry 8 } switchIfPhysPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This Integer is a Bit map specifying which physical ports are used by the IMA trunk. Bits corresponding to the physical ports forming this IMA trunk will be set to 1. Using this Integer we can represent maximum 32 ports. For regular ATM Routing trunk bit related to that port will be set. For access lines this field is unused and will return -1. For example: Value Ports used Trunk Type ----------------------------------------------- 0 Invalid Invalid 1 1 ATM RoutingTrk 2 2 ATM RoutingTrk 3 1 & 2 IMA RoutingTrk 4 3 ATM RoutingTrk 5 1 & 3 IMA RoutingTrk 15 1,2,3 & 4 IMA RoutingTrk " ::= { switchIfEntry 9} switchIfPartiId OBJECT-TYPE -- SYNTAX INTEGER (0..2) SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The partition ID for logical interface table row. A partition in the BXM resource is dedicated for control by the corresponding VSI Master. The partition is not available for any other cards. 0 indicates non-existent partition for all non-VSI controllers. " ::= { switchIfEntry 10 } switchIfCtrlerId OBJECT-TYPE -- SYNTAX INTEGER (-1..32) SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The controller ID for logical interface table row. The ID in the BXM resource is used to identify a VSI mster. No other card can have a VSI controller. -1 indicates an invalid controller ID" ::= { switchIfEntry 11 } -- The following describes the MIB variables for the frLportCnfTable. -- This table provides the manager a detailed view of the logical ports -- available on the switch. frLportCnfTable OBJECT-TYPE SYNTAX SEQUENCE OF FrLportCnfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Frame Relay Logical Port Configuration table. This table provides the following areas of information on per port basis: * Port identification * Current admin & operation status * Port-specific configuration * LMI-related configuration * Port error status * Pointer(s) to other tables" --DEFAULT test-function test-frlportcnftable --DEFAULT next-function next-frlportcnftable --DEFAULT get-function get-frlportcnftable-%t --DEFAULT view-mask IPX-VIEW ::= { frServiceObjects 1 } frLportCnfEntry OBJECT-TYPE SYNTAX FrLportCnfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Frame Relay Logical Port Configuration table. Some entries that are applicable to a specific FRI interface are indicated in the parenthesis, such as (FRI subrate/ T1/E1 interface only). Otherwise, they are used for both interfaces." INDEX { frLportSlotIndex , frLportPortIndex } ::= { frLportCnfTable 1 } FrLportCnfEntry ::= SEQUENCE { frLportSlotIndex INTEGER, frLportPortIndex INTEGER, frLportPortDLCI INTEGER, frLportAdminStatus INTEGER, frLportOperStatus INTEGER, frLportPortSpeed INTEGER, frLportClockType INTEGER, frLportPortType INTEGER, frLportVcCount INTEGER, frLportFirstVcPtr OBJECT IDENTIFIER, frLportAggrChCnt INTEGER, frLportChSpeed INTEGER, frLportMaxTxQDepth INTEGER, frLportECNQThresh INTEGER, frLportDEThresh INTEGER, frLportIDEMap INTEGER, frLportSigProt INTEGER, frLportNNIStatus INTEGER, frLportAsynStatus INTEGER, frLportPolVerTmr INTEGER, frLportErrThresh INTEGER, frLportMonEveCnt INTEGER, frLportCommPri INTEGER, frLportUpRNR INTEGER, frLportLowRNR INTEGER, frLportMinFrmFlgs INTEGER, frLportOamThresh INTEGER, frLportLinkTimer INTEGER, frLportPollCycle INTEGER, frLportCLLMTimer INTEGER, frLportEFCItoBECN INTEGER, frLportSrRTS INTEGER, frLportSrDTR INTEGER, frLportSrDCD INTEGER, frLportSrCTS INTEGER, frLportSrDSR INTEGER, frLportLoopBack INTEGER, frLportExtConFail INTEGER } frLportSlotIndex OBJECT-TYPE SYNTAX INTEGER (1..32) ACCESS read-only STATUS mandatory DESCRIPTION "The slot number" ::= { frLportCnfEntry 1 } frLportPortIndex OBJECT-TYPE SYNTAX INTEGER (1..32) ACCESS read-only STATUS mandatory DESCRIPTION "The port number" ::= { frLportCnfEntry 2 } frLportPortDLCI OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Port DLCI for Frame Forwarding (FRI subrate interface only). - Get Operation: If the network manager attempts to GET this object from a T1/E1 port, SNMP-OBJ-NA (Object Not Applicable -1) is returned." ::= { frLportCnfEntry 3 } frLportAdminStatus OBJECT-TYPE SYNTAX INTEGER { up(1), down(2), modify(3), writeOnly(4), add(5), delete(6) } ACCESS read-write STATUS mandatory DESCRIPTION "User requested state for logical port table row. A user may up, down, configure, add and delete a FR Logical port." ::= { frLportCnfEntry 4 } frLportOperStatus OBJECT-TYPE SYNTAX INTEGER { inActive(1), active (2), looped (3), failed (4), unknown (5) } ACCESS read-only STATUS mandatory DESCRIPTION "Actual state of the logical port." ::= { frLportCnfEntry 5 } frLportPortSpeed OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The baud rate of the port. For FRI T1/E1 interface, this object is determined when this port is added by the number of channels aggregated under it. Therefore, it can be configured only if the port is subrated. - Get Operation: OK for both T1/E1 and subrate interface. - Set Operation: If the network manager attempts to SET this object on a T1/E1 port, an error is reported." ::= { frLportCnfEntry 6 } frLportClockType OBJECT-TYPE SYNTAX INTEGER { normal (1), looped (2), none (3) } ACCESS read-write STATUS mandatory DESCRIPTION "The type of port clock (FRI subrate interface only). For T1/E1 interface this object should be none. - Get Operation: If the network manager attempts to get this object from a T1/E1 port, none (3) is returned. - Set Operation: If the network manager attempts to set this object on a T1/E1 port wit, none, oror none, looped type, an error is returned." ::= { frLportCnfEntry 7 } frLportPortType OBJECT-TYPE SYNTAX INTEGER { fr (1), atm (2) } ACCESS read-only STATUS mandatory DESCRIPTION "The type of FRP subrate port. This object is not used in switch software release 8.1 It is retained for historical reasons, and possible future enhancement." ::= { frLportCnfEntry 8 } frLportVcCount OBJECT-TYPE SYNTAX INTEGER (0..252) ACCESS read-only STATUS mandatory DESCRIPTION "The number of virtual connections that terminate on this port. Note that there can be up to 252 connections per FRP cards shared among the ports. A port may have up to 252 connections allocated." ::= { frLportCnfEntry 9 } frLportFirstVcPtr OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The object identifier denoting the first endpoint associated with this port. For current implementation, this OID points to the first frame relay connection on the port. It has a NULL OID value (i.e. { 0 0 }) if there is no frame relay connection on this port. The management station can retrieve all the information about the first connection by reading from row pointed to by this OID. Specifically, this OID specifies the first column of the appropriate row in the frEndptTable." ::= { frLportCnfEntry 10 } frLportAggrChCnt OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The number of aggregate channels assigned to this logical port (FRI T1/E1 interface only) when the port is added. For subrate ports, this object is always 1." ::= { frLportCnfEntry 11 } frLportChSpeed OBJECT-TYPE SYNTAX INTEGER { s56k (1), s64k (2), na (3) } ACCESS read-write STATUS mandatory DESCRIPTION "The channel speed (FRI T1/E1 interface only). For FRI subrate interface this object should be set as na." ::= { frLportCnfEntry 12 } frLportMaxTxQDepth OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The maximum bytes queued for transmission from the FRP port" ::= { frLportCnfEntry 13 } frLportECNQThresh OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port explicit congestion notification threshold. This is the point at which the BECN and FECN bits will be set in the communications to the user device." ::= { frLportCnfEntry 14 } frLportDEThresh OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-write STATUS mandatory DESCRIPTION "The percentage of the queue depth above which frames with the Discard Eligibility bit set will be discarded. An entry of 100% effectively disables DE for the port." ::= { frLportCnfEntry 15 } frLportIDEMap OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS mandatory DESCRIPTION "The flag indicating whether IDE to DE mapping should be performed." ::= { frLportCnfEntry 16 } frLportSigProt OBJECT-TYPE SYNTAX INTEGER { xdisabled (1), lmi-asyn (2), disabled (3), lmi-noasyn (4), uni-annexA (5), uni-annexD (6), nni-annexA (7), nni-annexD (8), auto-det (9) } ACCESS read-write STATUS mandatory DESCRIPTION "The specified LMI operation mode. The options can be 1 - (UNI)LMI disabled 2 - (UNI)LMI and asynchronous update enabled 3 - (UNI)LMI disabled 4 - (UNI)LMI enabled but asynchronous update disabled 5 - (UNI)LMI enabled using CCITT O.933 Annex A parameters 6 - (UNI)LMI enabled using ANSI T1.617 parameters 7 - (NNI)LMI enabled using CCITT O.933 Annex A parameters 8 - (NNI)LMI enabled using ANSI T1.617 parameters Note that option 7 and 8 are both bidirectional protocols defined by FRF.2 and available only if Frame Relay NNI feature is enabled." ::= { frLportCnfEntry 17 } frLportNNIStatus OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-only STATUS mandatory DESCRIPTION "The flag indicating whether NNI is active on the specified slot.port. - Get Operation only: This object is always NO if the network manager attempts to GET frLportNNIStatus from a disabled, LMI or LMI no update port. In other cases, the value of this object is determined by whether the port is configured as NNI or not." ::= { frLportCnfEntry 18 } frLportAsynStatus OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS mandatory DESCRIPTION "The flag indicating whether the IPX should send unsolicited LMI update messages as they appear or wait for the polling from the user device. This object is applicable to only Annex A/D UNI and Annex A/D NNI protocols for write and LMI, Annex A/D UNI and Annex A/D NNI for read. - Get Operation: This object is always NO for ports without protocols; otherwise, its value is determined by the asynchronous status of the port. - Set Operation: If the network manager attempts to SET this object of a port with none or LMI protocol, an error is reported." ::= { frLportCnfEntry 19 } frLportPolVerTmr OBJECT-TYPE SYNTAX INTEGER (5..30) ACCESS read-write STATUS mandatory DESCRIPTION "The link integrity verification timer heartbeat (keep-alive) period. It should be set to 5 seconds more than the heartbeat time in the user device. Default is 15 seconds. - Get Operation: Since this object is not applicable to disabled protocol, SNMP-OBJ-NA (-1) is returned if the network manager attempts to GET this object from a port without protocols. - Set Operation: If the network manager attempts to SET this object of a port without any protocol, an error is reported." ::= { frLportCnfEntry 20 } frLportErrThresh OBJECT-TYPE SYNTAX INTEGER (1..10) ACCESS read-write STATUS mandatory DESCRIPTION "The number of the failures in the monitored events that cause the keep-alive process to report an alarm. - Get Operation: Since this object is not applicable to disabled protocol, SNMP-OBJ-NA (-1) is returned if the network manager attempts to GET this object from a port without protocols. - Set Operation: If the network manager attempts to SET this object of a port without any protocol, an error is reported." ::= { frLportCnfEntry 21 } frLportMonEveCnt OBJECT-TYPE SYNTAX INTEGER (1..10) ACCESS read-write STATUS mandatory DESCRIPTION "The number of monitored events for the keep-alive process. A port communication fail condition is cleared after this number of successful polling cycles. - Get Operation: Since this object is not applicable to disabled protocol, SNMP-OBJ-NA (-1) is returned if the network manager attempts to GET this object from a port without protocols. - Set Operation: If the network manager attempts to SET this object of a port without any protocol, an error is reported." ::= { frLportCnfEntry 22 } frLportCommPri OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS mandatory DESCRIPTION "The flag specifying if the connection SNA priority should be communicated to the user device attached to the port. - Get Operation: Since this object is specific to LMI protocols, SNMP-OBJ-NA (-1) is returned if the network manager attempts to GET this object from a non-LMI port. - Set Operation: Likewise, if the network manager attempts to SET this object of a non-LMI port, an error is reported." ::= { frLportCnfEntry 23 } frLportUpRNR OBJECT-TYPE SYNTAX INTEGER (1..100) ACCESS read-write STATUS mandatory DESCRIPTION "The upper Receiver-Not-Ready threshold. This threshold specifies the number of receiver not ready indications from the user equipment before an alarm is generated for this connection. The default is 75. - Get Operation: Since this object is specific to LMI protocols, SNMP-OBJ-NA (-1) is returned if the network manager attempts to GET this object from a non-LMI port. - Set Operation: Likewise, if the network manager attempts to SET this object of a non-LMI port, an error is reported." ::= { frLportCnfEntry 24 } frLportLowRNR OBJECT-TYPE SYNTAX INTEGER (1..100) ACCESS read-write STATUS mandatory DESCRIPTION "The Lower Receiver-Not-Ready threshold. This threshold specifies the number of receiver not ready indications from the user equipment before an alarm is cleared for this connection. The default is 75. - Get Operation: Since this object is specific to LMI protocols, SNMP-OBJ-NA (-1) is returned if the network manager attempts to GET this object from a non-LMI port. - Set Operation: Likewise, if the network manager attempts to SET this object of a non-LMI port, an error is reported." ::= { frLportCnfEntry 25 } frLportMinFrmFlgs OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "The minimum number of flags between frames. All values in the range 1 to 255 are valid and the default is 1." ::= { frLportCnfEntry 26 } frLportOamThresh OBJECT-TYPE SYNTAX INTEGER (0..15) ACCESS read-write STATUS mandatory DESCRIPTION "The alarm threshold for number of OAM heartbeat FastPackets missed before propagating A-bit=0. This threshold is applicable to both UNI and NNI Frame Relay ports when the node has FR NNI feature enabled and this FRP firmware supports it. - Get Operation: Since this object is not applicable to disabled protocol, SNMP-OBJ-NA (-1) is returned if the network manager attempts to GET this object from a port without protocols. - Set Operation: If the network manager attempts to SET this object of a port without any protocol, an error is reported." ::= { frLportCnfEntry 27 } frLportLinkTimer OBJECT-TYPE SYNTAX INTEGER (5..30) ACCESS read-write STATUS mandatory DESCRIPTION "T391 - Link Integrity Timer (applicable to NNI FR port only), indicating the interval at which a Status Enquiry message is sent. This interval should be between 5 and 30 seconds with a default of 6 seconds. - Get Operation: the network manager attempts to GET this object from a port with a protocol other than NNIs, SNMP-OBJ-NA (-1) is returned. - Set Operation: If the network manager attempts to SET this object of a port with a protocol other than NNIs, an error is reported." ::= { frLportCnfEntry 28 } frLportPollCycle OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "N391 - Full Status Polling Cycle (applicable to NNI FR port only), indicating the interval (in terms of polling cycles) at which a Full Status Report of all PVCs is requested. The exact time duration is N391*T391. This interval should be between 1 and 255 polling cycles with a default of 6. - Get Operation: If the network manager attempts to GET this object from a port with a protocol other than NNIs, SNMP-OBJ-NA (-1) is returned. - Set Operation: If the network manager attempts to SET this object of a port with a protocol other than NNIs, an error is reported." ::= { frLportCnfEntry 29 } frLportCLLMTimer OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The timer for CLLM messages in CLLM intervals. No CLLM if 0 is configured. If a user configures this value to be greater than 0 then it should be in the range 4 to 35. The unit is hundredth of a sec. Note that ForeSight (CLLM) is available only if the firmware supports it. - Get Operation: If the network manager attempts to GET this object from a port where ForeSight is not supported, SNMP-OBJ-NA (-1) is returned. - Set Operation: If the network manager attempts to SET this object of a port where ForeSight is not supported, an error is reported." ::= { frLportCnfEntry 30 } frLportEFCItoBECN OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2), na (3) } ACCESS read-write STATUS mandatory DESCRIPTION "This object indicates whether EFCI to BECN mapping is enabled." ::= { frLportCnfEntry 31 } frLportSrRTS OBJECT-TYPE SYNTAX INTEGER { off (1), on (2), na (3) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of the RTS lead (subrated FRI only). Na is used for T1/E1 FRI. - Get Operation: This object is valid only if the port is subrated and DTE. Otherwise, na is returned." ::= { frLportCnfEntry 32 } frLportSrDTR OBJECT-TYPE SYNTAX INTEGER { off (1), on (2), na (3) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of the DTR lead (subrated FRI only). Na is used for T1/E1 FRI. - Get Operation: This object is valid only if the port is subrated and DTE. Otherwise, na is returned." ::= { frLportCnfEntry 33 } frLportSrDCD OBJECT-TYPE SYNTAX INTEGER { off (1), on (2), na (3) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of the DCD lead (subrated FRI only). Na is used for T1/E1 FRI. - Get Operation: This object is valid only if the port is subrated and DCE. Otherwise, na is returned." ::= { frLportCnfEntry 34 } frLportSrCTS OBJECT-TYPE SYNTAX INTEGER { off (1), on (2), na (3) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of the CTS lead (subrated FRI only). Na is used for T1/E1 FRI. - Get Operation: This object is valid only if the port is subrated and DCE. Otherwise, na is returned." ::= { frLportCnfEntry 35 } frLportSrDSR OBJECT-TYPE SYNTAX INTEGER { off (1), on (2), na (3) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of the DSR lead (subrated FRI only). Na is used for T1/E1 FRI. - Get Operation: This object is valid only if the port is subrated and DCE. Otherwise, na is returned." ::= { frLportCnfEntry 36 } frLportLoopBack OBJECT-TYPE SYNTAX INTEGER { none (1), local (2) } ACCESS read-only STATUS mandatory DESCRIPTION "The loopback mode" ::= { frLportCnfEntry 37 } frLportExtConFail OBJECT-TYPE SYNTAX INTEGER { false (1), true (2) } ACCESS read-only STATUS mandatory DESCRIPTION "The flag indicating if the connection with the external device is lost." ::= { frLportCnfEntry 38 } -- The following describes the MIB variables for the frLportStatTable. -- This table provides the manager access to the statistics available -- on the logical ports. frLportStatTable OBJECT-TYPE SYNTAX SEQUENCE OF FrLportStatEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Frame Relay Logical Port Statistics table. This table ...." --DEFAULT test-function test-frlportstattable --DEFAULT next-function next-frlportstattable --DEFAULT get-function get-frlportstattable-%t --DEFAULT view-mask IPX-VIEW --DEFAULT locator FRLPORT-STAT-LOCATOR ::= { frServiceObjects 2 } frLportStatEntry OBJECT-TYPE SYNTAX FrLportStatEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Frame Relay Logical Port Statistics table." INDEX { frLportSlotIndex , frLportPortIndex } ::= { frLportStatTable 1 } FrLportStatEntry ::= SEQUENCE { frLportRxBytes Counter, frLportRxFrms Counter, frLportTxBytes Counter, frLportTxFrms Counter, frLportTxFrmsFecns Counter, frLportTxFrmsBecns Counter, frLportCrcErrors Counter, frLportBadFmts Counter, frLportAlgnErrors Counter, frLportIllegLengths Counter, frLportDmaOvruns Counter, frLportStatEnqUnis Counter, frLportStatTxUnis Counter, frLportUpdtTxUnis Counter, frLportInvldReqCnts Counter, frLportToutCntUnis Counter, frLportSeqnmErrUnis Counter, frLportUnknDlcis Counter, frLportDeFrmsDrops Counter, frLportStatEnqNnis Counter, frLportStatRxNnis Counter, frLportUpdtRxNnis Counter, frLportToutCntNnis Counter, frLportSeqnmErrNnis Counter, frLportCllmTxFrms Counter, frLportCllmTxBytes Counter, frLportCllmRxFrms Counter, frLportCllmRxBytes Counter, frLportCllmFailures Counter, frLportDscdQTxFrms Counter, frLportDscdQTxBytes Counter, frLportLmiFailFrms Counter, frLportLmiFailBytes Counter } frLportRxBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Logical Port Rx bytes" ::= { frLportStatEntry 1 } frLportRxFrms OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Logical Port Rx frames" ::= { frLportStatEntry 2 } frLportTxBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Logical Port Tx bytes" ::= { frLportStatEntry 3 } frLportTxFrms OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Logical Port Tx frames" ::= { frLportStatEntry 4 } frLportTxFrmsFecns OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Logical Port Tx FECN frames" ::= { frLportStatEntry 5 } frLportTxFrmsBecns OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Logical Port Tx BECN frames" ::= { frLportStatEntry 6 } frLportCrcErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Logical Port CRC errors on received frames" ::= { frLportStatEntry 7 } frLportBadFmts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Logical Port frames with illegal formats" ::= { frLportStatEntry 8 } frLportAlgnErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Logical Port Alignment errors on received frames" ::= { frLportStatEntry 9 } frLportIllegLengths OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Logical Port Illegal length on received frames" ::= { frLportStatEntry 10 } frLportDmaOvruns OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Logical Port number of DMA overruns" ::= { frLportStatEntry 11 } frLportStatEnqUnis OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Logical Port status enquiry count. Transmit protocol LMI UNI." ::= { frLportStatEntry 12 } frLportStatTxUnis OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Logical Port status transmit count. Transmit protocol LMI UNI." ::= { frLportStatEntry 13 } frLportUpdtTxUnis OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Logical Port update transmit count. Transmit protocol LMI UNI." ::= { frLportStatEntry 14 } frLportInvldReqCnts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Logical Port invalid request count. UNI and NNI." ::= { frLportStatEntry 15 } frLportToutCntUnis OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Logical Port timeout count. Transmit protocol LMI UNI." ::= { frLportStatEntry 16 } frLportSeqnmErrUnis OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Logical Port sequence number error. Transmit protocol UNI." ::= { frLportStatEntry 17 } frLportUnknDlcis OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Logical Port number of unknown DLCI's on received frames." ::= { frLportStatEntry 18 } frLportDeFrmsDrops OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Logical Port number of DE dropped frames." ::= { frLportStatEntry 19 } frLportStatEnqNnis OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Logical Port status enquiry count. Transmit protocol LMI NNIs." ::= { frLportStatEntry 20 } frLportStatRxNnis OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Logical Port status transmit count. Transmit protocol LMI NNIs." ::= { frLportStatEntry 21 } frLportUpdtRxNnis OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Logical Port update transmit count. Transmit protocol LMI NNIs." ::= { frLportStatEntry 22 } frLportToutCntNnis OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Logical Port timeout count. Transmit protocol LMI NNIs." ::= { frLportStatEntry 23 } frLportSeqnmErrNnis OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Logical Port sequence number error. Transmit protocol NNIs." ::= { frLportStatEntry 24 } frLportCllmTxFrms OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Logical Port CLLM (Foresight) Tx frames" ::= { frLportStatEntry 25 } frLportCllmTxBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Logical Port CLLM (Foresight) Tx bytes" ::= { frLportStatEntry 26 } frLportCllmRxFrms OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Logical Port CLLM (Foresight) Rx frames" ::= { frLportStatEntry 27 } frLportCllmRxBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Logical Port CLLM (Foresight) Rx bytes" ::= { frLportStatEntry 28 } frLportCllmFailures OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Logical Port CLLM (Foresight) failures" ::= { frLportStatEntry 29 } frLportDscdQTxFrms OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Logical Port discard queue Tx frames" ::= { frLportStatEntry 30 } frLportDscdQTxBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Logical Port discard queue Tx bytes" ::= { frLportStatEntry 31 } frLportLmiFailFrms OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Logical Port LMI failure frames" ::= { frLportStatEntry 32 } frLportLmiFailBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Logical Port LMI failure bytes" ::= { frLportStatEntry 33 } -- -- The following describes the MIB variables for the atmPortTable. -- This table provides the manager a detailed view of the ATM ports -- available on the switch. atmPortTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The ATM Port Configuration table." --DEFAULT test-function test-atmporttable --DEFAULT next-function next-atmporttable --DEFAULT get-function get-atmporttable-%t --DEFAULT view-mask BPX-VIEW ::= { atmServiceObjects 1 } atmPortEntry OBJECT-TYPE SYNTAX AtmPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the ATM Port Configuration table." INDEX { atmPortSlot , atmPortPort } ::= { atmPortTable 1 } AtmPortEntry ::= SEQUENCE { atmPortSlot INTEGER, atmPortPort INTEGER, atmPortAdminStatus INTEGER, atmPortOperStatus INTEGER, atmPortType INTEGER, atmPortIfType INTEGER, atmPortSpeed INTEGER, atmPortAxis INTEGER, atmPortVcCount INTEGER, atmPortFirstVcPtr OBJECT IDENTIFIER, atmPortMetro INTEGER, atmPortMgmtProto INTEGER, atmPortIlmiVpi INTEGER, atmPortIlmiVci INTEGER, atmPortIlmiPollEnable INTEGER, atmPortIlmiTrapEnable INTEGER, atmPortIlmiPollIntrvl INTEGER, atmPortIlmiErrorThresh INTEGER, atmPortIlmiEventThresh INTEGER, atmPortLmiVpi INTEGER, atmPortLmiVci INTEGER, atmPortLmiPollEnable INTEGER, atmPortLmiStatEnqTimer INTEGER, atmPortLmiUpdStatTimer INTEGER, atmPortLmiStatEnqRetry INTEGER, atmPortLmiUpdStatRetry INTEGER, atmPortLmiPollTimer INTEGER, atmPortPercUtil INTEGER } atmPortSlot OBJECT-TYPE SYNTAX INTEGER (1..32) ACCESS read-only STATUS mandatory DESCRIPTION "The slot number" ::= { atmPortEntry 1 } atmPortPort OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "The port number" ::= { atmPortEntry 2 } atmPortAdminStatus OBJECT-TYPE SYNTAX INTEGER { up(1), down(2), modify(3), writeOnly(4) } ACCESS read-write STATUS mandatory DESCRIPTION "User requested state for port table row. A user may Up or Down an existing port. The user may also modify the characteristics of the port." ::= { atmPortEntry 3 } atmPortOperStatus OBJECT-TYPE SYNTAX INTEGER { inactive(1), active (2), looped (3), failed (4), unknown (5) } ACCESS read-only STATUS mandatory DESCRIPTION "Actual state of the port." ::= { atmPortEntry 4 } atmPortType OBJECT-TYPE SYNTAX INTEGER { uni (1), nni (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates whether this is a UNI or NNI port. The switch supports this operation only on a per-card level, so changing one port changes the other also. The value of this object cannot be changed if there are active connections on the card." ::= { atmPortEntry 5 } atmPortIfType OBJECT-TYPE SYNTAX INTEGER { unknown (1), t3 (2), e3 (3), oc3-smf (4), oc3-mmf (5) } ACCESS read-only STATUS mandatory DESCRIPTION "The type of interface for this port." ::= { atmPortEntry 6 } atmPortSpeed OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The speed of the port in cells per seconds." ::= { atmPortEntry 7 } atmPortAxis OBJECT-TYPE SYNTAX INTEGER { none (1), t1 (2), e1 (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates port support for BASIS shelf. The value of this object cannot be changed if there are active connections on the port. For ASI-2 the value of this object is 'none'. An attempt to change the value of this object on an ASI-2 will return a BadValue error." ::= { atmPortEntry 8 } atmPortVcCount OBJECT-TYPE SYNTAX INTEGER (0..1024) ACCESS read-only STATUS mandatory DESCRIPTION "The number of virtual connections that terminate on this port. A port may have up to 1024 connections allocated." ::= { atmPortEntry 9 } atmPortFirstVcPtr OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The object identifier denoting the first connection endpoint associated with this port. For current implementation, this OID points to the first connection on the port. It has a NULL OID value (i.e. { 0 0 }) if there is no connection on this port. The management station can retrieve all the information about the first connection by reading from row pointed to by this OID. Specifically, this OID specifies the first column of the appropriate row in the atmEndptTable." ::= { atmPortEntry 10 } atmPortMetro OBJECT-TYPE SYNTAX INTEGER { enable (1), disable (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Metro Data Cell Header Format. This object applies to T3 non-axis ports. The value of this object is set to disable by the switch every time that the value of the object atmPortAxis changes to or from 'none'." ::= { atmPortEntry 11 } atmPortMgmtProto OBJECT-TYPE SYNTAX INTEGER { none (1), lmi (2), ilmi (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the port management protocol used for this port." ::= { atmPortEntry 12 } atmPortIlmiVpi OBJECT-TYPE SYNTAX INTEGER (0..4095) ACCESS read-write STATUS mandatory DESCRIPTION "The virtual path identifier for the ILMI protocol." ::= { atmPortEntry 13 } atmPortIlmiVci OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The virtual channel identifier for the ILMI protocol." ::= { atmPortEntry 14 } atmPortIlmiPollEnable OBJECT-TYPE SYNTAX INTEGER { enable (1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable ILMI keep alive polling procedure." ::= { atmPortEntry 15 } atmPortIlmiTrapEnable OBJECT-TYPE SYNTAX INTEGER { enable (1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "if enabled the ILMI agent will send unsolicited Trap PDUs." ::= { atmPortEntry 16 } atmPortIlmiPollIntrvl OBJECT-TYPE SYNTAX INTEGER (5..60) ACCESS read-write STATUS mandatory DESCRIPTION "The number of seconds between each keep alive poll transmitted by the port (T491)." ::= { atmPortEntry 17 } atmPortIlmiErrorThresh OBJECT-TYPE SYNTAX INTEGER (1..10) ACCESS read-write STATUS mandatory DESCRIPTION "The number of keep alive polls that must fail within a window of N492 polls, before the port is placed in the failed state (N491)." ::= { atmPortEntry 18 } atmPortIlmiEventThresh OBJECT-TYPE SYNTAX INTEGER (1..10) ACCESS read-write STATUS mandatory DESCRIPTION "It specifies the number of keep alive polls within which if N491 polls fail the port is placed in the failed state (N492)." ::= { atmPortEntry 19 } atmPortLmiVpi OBJECT-TYPE SYNTAX INTEGER (0..4095) ACCESS read-write STATUS mandatory DESCRIPTION "The virtual path identifier for the LMI protocol." ::= { atmPortEntry 20 } atmPortLmiVci OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The virtual channel identifier for the ILMI protocol." ::= { atmPortEntry 21 } atmPortLmiPollEnable OBJECT-TYPE SYNTAX INTEGER { enable (1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "if enable an Status Enquiry message is sent when the polling timer expires." ::= { atmPortEntry 22 } atmPortLmiStatEnqTimer OBJECT-TYPE SYNTAX INTEGER (5..30) ACCESS read-write STATUS mandatory DESCRIPTION "Link integrity timer for the port (T393)." ::= { atmPortEntry 23 } atmPortLmiUpdStatTimer OBJECT-TYPE SYNTAX INTEGER (5..30) ACCESS read-write STATUS mandatory DESCRIPTION "Update status timer for the port (T394)." ::= { atmPortEntry 24 } atmPortLmiStatEnqRetry OBJECT-TYPE SYNTAX INTEGER (1..10) ACCESS read-write STATUS mandatory DESCRIPTION "The maximum number of times a Status Enquiry message is retransmitted. A Status Enquiry message is retransmitted when timer T393 expires (N394)." ::= { atmPortEntry 25 } atmPortLmiUpdStatRetry OBJECT-TYPE SYNTAX INTEGER (1..10) ACCESS read-write STATUS mandatory DESCRIPTION "The maximum number of times an Update Status message is retransmitted. An Update Status message is retransmitted when timer T394 expires (N395)." ::= { atmPortEntry 26 } atmPortLmiPollTimer OBJECT-TYPE SYNTAX INTEGER (5..30) ACCESS read-write STATUS mandatory DESCRIPTION "Polling timer (T396). If polling is enabled a Status Enquiry message is sent when this timer expires." ::= { atmPortEntry 27 } atmPortPercUtil OBJECT-TYPE SYNTAX INTEGER { enable (1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Percentage Utilization can be disabled or enabled. If the use of percent utilization is disabled, the bandwidth for the connections terminating on the port will be used to determine the port load. If the use of percent utilization is enabled, the bandwidth for the connection is multiplied by the percent utilization for the connection to determine the port load." ::= { atmPortEntry 28 } -- -- The following describes the MIB variables for the atmPortQueueTable. -- This table provides the manager access to read and configure the -- ATM port egress queues. atmPortQueueTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmPortQueueEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The ATM port egress queue table." --DEFAULT test-function test-atmportqueuetable --DEFAULT next-function next-atmportqueuetable --DEFAULT get-function get-atmportqueuetable-%t --DEFAULT view-mask BPX-VIEW ::= { atmServiceObjects 2 } atmPortQueueEntry OBJECT-TYPE SYNTAX AtmPortQueueEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the ATM port queue table." INDEX { atmPortSlot , atmPortPort , atmPortQueueIndex } ::= { atmPortQueueTable 1 } AtmPortQueueEntry ::= SEQUENCE { atmPortQueueIndex INTEGER, atmPortQueueAdminStatus INTEGER, atmPortQueueType INTEGER, atmPortQueueDepth INTEGER, atmPortQueueClpHi INTEGER, atmPortQueueClpLo INTEGER, atmPortQueueEfciTh INTEGER, atmPortQueueAlgorithm INTEGER } atmPortQueueIndex OBJECT-TYPE SYNTAX INTEGER (0..15) ACCESS read-only STATUS mandatory DESCRIPTION "Index into the port egress queue array of the given port that uniquely identifies this queue. if the value of the atmPortQueueType object is 'axis', then the value of this object also specifies the Axis slot associated with this queue." ::= { atmPortQueueEntry 1 } atmPortQueueAdminStatus OBJECT-TYPE SYNTAX INTEGER { modify(1), writeOnly(2) } ACCESS read-write STATUS mandatory DESCRIPTION "User requested state for this port queue table row. The only operation supported in this table is modify." ::= { atmPortQueueEntry 2 } atmPortQueueType OBJECT-TYPE SYNTAX INTEGER { unknown (1), unused (2), cbr (3), abr (4), vbr (5), axis (6) } ACCESS read-only STATUS mandatory DESCRIPTION "The type of the queue. If the type is 'axis', then the atmPortQueueIndex specifes the Axis slot associated with this queue." ::= { atmPortQueueEntry 3 } atmPortQueueDepth OBJECT-TYPE SYNTAX INTEGER (0..11000) ACCESS read-write STATUS mandatory DESCRIPTION "The storage depth allocated to this queue in block of cells. The block size is one cell for T3/E3 and 64 cells for OC3. The aggregate of the queue depths for all queues cannot exceed the maximum storage available for the port." ::= { atmPortQueueEntry 4 } atmPortQueueClpHi OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-write STATUS mandatory DESCRIPTION "The CLP tagging activation threshold for this queue expressed as a percentage of queue depth." ::= { atmPortQueueEntry 5 } atmPortQueueClpLo OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-write STATUS mandatory DESCRIPTION "The CLP tagging deactivation threshold for this queue expressed as a percentage of queue depth." ::= { atmPortQueueEntry 6 } atmPortQueueEfciTh OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-write STATUS mandatory DESCRIPTION "The EFCI threshold for this queue expressed as a percentage of queue depth." ::= { atmPortQueueEntry 7 } atmPortQueueAlgorithm OBJECT-TYPE SYNTAX INTEGER { off (1), always (2), ok (3), minGuar (4), minSmooth (5), minDelay (6) } ACCESS read-only STATUS mandatory DESCRIPTION "The queue service algorithm: off: never serve always: always serve ok: ok to serve, not minimum guaranteed min-guar: minimum guaranteed bw, no limit min-smooth: minimum guaranteed bw, smoothed min-delay: minimum guaranteed bw, delay limited " ::= { atmPortQueueEntry 8 } -- -- The following describes the MIB variables for the atmPortStatTable. -- This table provides the manager access to the statistics available -- on the ATM ports. atmPortStatTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmPortStatEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The ATM Port Statistics table." --DEFAULT test-function test-atmportstattable --DEFAULT next-function next-atmportstattable --DEFAULT get-function get-atmportstattable-%t --DEFAULT view-mask BPX-VIEW ::= { atmServiceObjects 3 } atmPortStatEntry OBJECT-TYPE SYNTAX AtmPortStatEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the ATM Port Statistics table." INDEX { atmPortSlot , atmPortPort } ::= { atmPortStatTable 1 } AtmPortStatEntry ::= SEQUENCE { atmPortStatUnknVpiVcis Counter, atmPortStatBufferOvfls Counter, atmPortStatNonZeroGfcs Counter, atmPortStatIsuDiscards Counter, atmPortStatIsuEmptys Counter, atmPortStatAisRxs Counter, atmPortStatFerfRxs Counter, atmPortStatCellsRxs Counter, atmPortStatClpRxs Counter, atmPortStatEfciRxs Counter, atmPortStatBcmRxs Counter, atmPortStatCellsTxs Counter, atmPortStatOamRxs Counter, atmPortStatPayldErrs Counter, atmPortStatClpTxs Counter, atmPortStatEfciTxs Counter, atmPortStatHdrDiscards Counter, atmPortStatIlmiGetRxs Counter, atmPortStatIlmiGetNextRxs Counter, atmPortStatIlmiGetNextTxs Counter, atmPortStatIlmiSetRxs Counter, atmPortStatIlmiTrapRxs Counter, atmPortStatIlmiGetRspRxs Counter, atmPortStatIlmiGetTxs Counter, atmPortStatIlmiGetRspTxs Counter, atmPortStatIlmiTrapTxs Counter, atmPortStatIlmiUnkRxs Counter, atmPortStatLmiStatTxs Counter, atmPortStatLmiUpdtStatTxs Counter, atmPortStatLmiStatAckTxs Counter, atmPortStatLmiStatEnqRxs Counter, atmPortStatLmiStatEnqTxs Counter, atmPortStatLmiStatRxs Counter, atmPortStatLmiUpdStatRxs Counter, atmPortStatLmiStatAckRxs Counter } atmPortStatUnknVpiVcis OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of cells discarded due to unknown address." ::= { atmPortStatEntry 1 } atmPortStatBufferOvfls OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of times the port has incurred a cell buffer overflow." ::= { atmPortStatEntry 2 } atmPortStatNonZeroGfcs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of non-zero GFC cells for a UNI port. For a NNI port this value is 0." ::= { atmPortStatEntry 3 } atmPortStatIsuDiscards OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The count of cells discarded by the Ingress Control Service Unit." ::= { atmPortStatEntry 4 } atmPortStatIsuEmptys OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The Ingress Control Service Unit free list empty count." ::= { atmPortStatEntry 5 } atmPortStatAisRxs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total numbers of cells received with AIS." ::= { atmPortStatEntry 6 } atmPortStatFerfRxs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total numbers of cells received with FERF." ::= { atmPortStatEntry 7 } atmPortStatCellsRxs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total numbers of cells received." ::= { atmPortStatEntry 8 } atmPortStatClpRxs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "numbers of cells received with CLP set." ::= { atmPortStatEntry 9 } atmPortStatEfciRxs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total numbers of cells received with EFCI set." ::= { atmPortStatEntry 10 } atmPortStatBcmRxs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total numbers of BCM cells received." ::= { atmPortStatEntry 11 } atmPortStatCellsTxs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total numbers of cells transmitted." ::= { atmPortStatEntry 12 } atmPortStatOamRxs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total numbers of OAM cells received." ::= { atmPortStatEntry 13 } atmPortStatPayldErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total numbers of cells discarded due to BIP-16." ::= { atmPortStatEntry 14 } atmPortStatClpTxs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total numbers of cells transmitted with CLP set." ::= { atmPortStatEntry 15 } atmPortStatEfciTxs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total numbers of cells transmitted with EFCI set." ::= { atmPortStatEntry 16 } atmPortStatHdrDiscards OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total numbers of cells discarded due to parity error." ::= { atmPortStatEntry 17 } atmPortStatIlmiGetRxs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "ILMI Get requests received." ::= { atmPortStatEntry 18 } atmPortStatIlmiGetNextRxs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "ILMI Get Next requests received." ::= { atmPortStatEntry 19 } atmPortStatIlmiGetNextTxs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "ILMI Get Next requests transmitted." ::= { atmPortStatEntry 20 } atmPortStatIlmiSetRxs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "ILMI Set requests received." ::= { atmPortStatEntry 21 } atmPortStatIlmiTrapRxs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "ILMI Trap received." ::= { atmPortStatEntry 22 } atmPortStatIlmiGetRspRxs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "ILMI Get Response messages received." ::= { atmPortStatEntry 23 } atmPortStatIlmiGetTxs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "ILMI Get requests transmitted." ::= { atmPortStatEntry 24 } atmPortStatIlmiGetRspTxs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "ILMI Get Response messages transmitted." ::= { atmPortStatEntry 25 } atmPortStatIlmiTrapTxs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "ILMI Traps transmitted." ::= { atmPortStatEntry 26 } atmPortStatIlmiUnkRxs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Unknown PDU type received." ::= { atmPortStatEntry 27 } atmPortStatLmiStatTxs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "LMI Status messages transmitted." ::= { atmPortStatEntry 28 } atmPortStatLmiUpdtStatTxs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "LMI Update Status messages transmitted." ::= { atmPortStatEntry 29 } atmPortStatLmiStatAckTxs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "LMI Status Acknowledge messages transmitted." ::= { atmPortStatEntry 30 } atmPortStatLmiStatEnqTxs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "LMI Status Enquiry messages transmitted." ::= { atmPortStatEntry 31 } atmPortStatLmiStatEnqRxs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "LMI Status Enquiry messages received." ::= { atmPortStatEntry 32 } atmPortStatLmiStatRxs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "LMI Status messages received." ::= { atmPortStatEntry 33 } atmPortStatLmiUpdStatRxs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "LMI Update Status messages received." ::= { atmPortStatEntry 34 } atmPortStatLmiStatAckRxs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "LMI Status Acknowledge messages received." ::= { atmPortStatEntry 35 } -- -- The voiceChannel Table -- voiceChannelTable OBJECT-TYPE SYNTAX SEQUENCE OF VoiceChannelEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The voice channel table has channel specific configuration information. This is available for each of the voice channel." --DEFAULT test-function test-vochantable --DEFAULT next-function next-vochantable --DEFAULT get-function get-vochantable-%t --DEFAULT view-mask IPX-VIEW ::= { voiceServiceObjects 1 } voiceChannelEntry OBJECT-TYPE SYNTAX VoiceChannelEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the voice Channel information table." INDEX { voiceChannelSlotIndex, voiceChannelChannelIndex } ::= { voiceChannelTable 1 } VoiceChannelEntry ::= SEQUENCE { voiceChannelSlotIndex INTEGER, voiceChannelChannelIndex INTEGER, voiceChannelAdminStatus INTEGER, voiceChannelEndptPtr OBJECT IDENTIFIER, voiceChannelIf INTEGER, voiceChannelAdapVoice INTEGER, voiceChannelDialType INTEGER, voiceChannelDtSignallingDelay INTEGER, voiceChannelDtMinWink INTEGER, voiceChannelDtPlayOutDelay INTEGER, voiceChannelRecvSigABit INTEGER, voiceChannelRecvSigBBit INTEGER, voiceChannelRecvSigCBit INTEGER, voiceChannelRecvSigDBit INTEGER, voiceChannelXmitSigABit INTEGER, voiceChannelXmitSigBBit INTEGER, voiceChannelXmitSigCBit INTEGER, voiceChannelXmitSigDBit INTEGER, voiceChannelIfTypeName INTEGER, voiceChannelIfOnhkABit INTEGER, voiceChannelIfOnhkBBit INTEGER, voiceChannelIfOnhkCBit INTEGER, voiceChannelIfOnhkDBit INTEGER, voiceChannelIfCondIndex INTEGER, voiceChannelEchoCancel INTEGER, voiceChannelEchoRtnLoss INTEGER, voiceChannelEchoTone INTEGER, voiceChannelEchoConv INTEGER, voiceChannelEchoNlp INTEGER, voiceChannelInGain INTEGER, voiceChannelOutGain INTEGER, voiceChannelUtil INTEGER } voiceChannelSlotIndex OBJECT-TYPE SYNTAX INTEGER (1..32) ACCESS read-only STATUS mandatory DESCRIPTION " The Slot Number." ::= { voiceChannelEntry 1 } voiceChannelChannelIndex OBJECT-TYPE SYNTAX INTEGER (1..32) ACCESS read-only STATUS mandatory DESCRIPTION "The channel number. This shall serve as the index to this table" ::= { voiceChannelEntry 2 } voiceChannelAdminStatus OBJECT-TYPE SYNTAX INTEGER { create(1), modify(2), writeOnly(3) } ACCESS read-write STATUS mandatory DESCRIPTION "User requested operation for this table. The operations supported on this table are modify and create The existing interfaceTypes cannot be changed (Please refer to voiceChannelIfTypeName variable definition). For associating a channel with a new interfaceType, all the values of the columns specified in the Description clause of voiceChannelIfTypeName should be provided." ::= { voiceChannelEntry 3 } voiceChannelEndptPtr OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "Pointer to channel End point table. This may not necessarily have a value. In the case that there is no corresponding voiceChannelEntry in the endpoint table, this would be 0." ::= { voiceChannelEntry 4 } voiceChannelIf OBJECT-TYPE SYNTAX INTEGER { unknown (1), t1 (2), e1 (3) } ACCESS read-only STATUS mandatory DESCRIPTION "The type of the line interface associated with this channel" ::= { voiceChannelEntry 5 } voiceChannelAdapVoice OBJECT-TYPE SYNTAX INTEGER { false(1), true(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines whether the channel is configured for Adaptive voice. This feature must be configured at both ends of the channel. The adaptive voice feature must also be equipped at each node terminating the connection. If the adaptive voice feature is enabled for a channel connection which is used for a 'c' or 'v' connection, VAD is automatically disabled on that channel when trunk bandwidth is available, and it is enabled when trunk bandwidth is needed. By DEFAULT this is True. This variable is not applicable, if the channel is used for signalling." ::= { voiceChannelEntry 6 } voiceChannelDialType OBJECT-TYPE SYNTAX INTEGER { inband(1), pulse(2), userConfigured(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Information about dail type used on the channel. By default Inband dail type is used. In case it is of type userConfigured, the related objects for which values need to be provided are : voiceChannelSignallingDelay voiceChannelMinWink voiceChannelPlayOutDelay. If the values for any of the above variables are not provided for User Configured Dial type, the current values in the Database shall be retained. Each of the variables can be set independently. These hold good for the CDP and CIP cards. By default every voice connection is configured with Inband signalling. When the dialType is Inband or Pulse, these are the values which are allowed : SignallingType Inband Pulse voiceChannelSignallingDelay 96 96 voiceChannelMinWink 20 20 voiceChannelPlayOutDelay 200 200. When the dial type is INBAND or PULSE SET on the related objects mentioned above are not allowed" ::= { voiceChannelEntry 7 } voiceChannelDtSignallingDelay OBJECT-TYPE SYNTAX INTEGER (30..96) ACCESS read-write STATUS mandatory DESCRIPTION "It is the signalling delay, in milliseconds (ms), to assign the user configurable dail type. The value specified is rounded to the closest multiple of 1.5 ms. The default value for inband - 96 pulse - 96. When the dial type is Inband or Pulse value for this object should not be provided." ::= { voiceChannelEntry 8 } voiceChannelDtMinWink OBJECT-TYPE SYNTAX INTEGER (120..300) ACCESS read-write STATUS mandatory DESCRIPTION "It is the minimum wink, in milliseconds, to assign to the user configurable dial type. The value specified is rounded off to the nearest whole multiple of 3ms. The default value for inband - 20 pulse - 20. When the dial type is Inband or Pulse value for this object should not be provided." ::= { voiceChannelEntry 9 } voiceChannelDtPlayOutDelay OBJECT-TYPE SYNTAX INTEGER (100..200) ACCESS read-write STATUS mandatory DESCRIPTION "It is the playout delay, in milliseconds, assigned to the user configurable dial type. The value specified is rounded to the closest multiple of 1.5 second. The default value for inband - 200 pulse - 200. When the dial type is Inband or Pulse value for this object should not be provided." ::= { voiceChannelEntry 10 } voiceChannelRecvSigABit OBJECT-TYPE SYNTAX INTEGER { zero (1), one (2), xmitTransparent(3), donotXmit(4), revSigBit(5) } ACCESS read-write STATUS mandatory DESCRIPTION "It represents the configuration of bit conversion to received signalling on a channel. The value is given as one of the enumeration above which have following meaning: one(1) : Signalling bit is 1 zero(2) : Signalling bit is 0 xmitTransparent(3) : Transmit signalling bit transparently noXmit(4) : Don't transmit signalling bit revSigBit(5) : Reverse/Inverse signalling bit. The default value is one. If the signalling is not used at all, the A B C and D bits have 1 1 0 1 values respectively. The initialization value is xmitTransparent(3)" ::= { voiceChannelEntry 11 } voiceChannelRecvSigBBit OBJECT-TYPE SYNTAX INTEGER { zero (1), one (2), xmitTransparent(3), donotXmit(4), revSigBit(5) } ACCESS read-write STATUS mandatory DESCRIPTION "It represents the configuration of bit conversion to received signalling on a channel. The value is given as one of the enumeration above which have following meaning: one(1) : Signalling bit is 1 zero(2) : Signalling bit is 0 xmitTransparent(3) : Transmit signalling bit transparently donotXmit(4) : Don't transmit signalling bit revSigBit(5) : Reverse/Inverse signalling bit. The default value is one. If the signalling is not used at all, the A B C and D bits have 1 1 0 1 values respectively. The initialization value is xmitTransparent(3)." ::= { voiceChannelEntry 12 } voiceChannelRecvSigCBit OBJECT-TYPE SYNTAX INTEGER { zero (1), one (2), xmitTransparent(3), donotXmit(4), revSigBit(5) } ACCESS read-write STATUS mandatory DESCRIPTION "It represents the configuration of bit conversion to received signalling on a channel. The value is given as one of the enumeration above which have following meaning: one(1) : Signalling bit is 1 zero(2) : Signalling bit is 0 xmitTransparent(3) : Transmit signalling bit transparently donotXmit(4) : Don't transmit signalling bit revSigBit(5) : Reverse/Inverse signalling bit. The default value is zero. If the signalling is not used at all, the A B C and D bits have 1 1 0 1 values respectively. The initialization value is xmitTransparent(3)" ::= { voiceChannelEntry 13 } voiceChannelRecvSigDBit OBJECT-TYPE SYNTAX INTEGER { zero (1), one (2), xmitTransparent(3), donotXmit(4), revSigBit(5) } ACCESS read-write STATUS mandatory DESCRIPTION "It represents the configuration of bit conversion to received signalling on a channel. The value is given as one of the enumeration above which have following meaning: one(1) : Signalling bit is 1 zero(2) : Signalling bit is 0 xmitTransparent(3) : Transmit signalling bit transparently donoXmit(4) : Don't transmit signalling bit revSigBit(5) : Reverse/Inverse signalling bit. The default value is one. If the signalling is not used at all, the A B C and D bits have 1 1 0 1 values respectively. The initialization values is xmitTransparent(3)" ::= { voiceChannelEntry 14 } voiceChannelXmitSigABit OBJECT-TYPE SYNTAX INTEGER { zero (1), one (2), xmitTransparent(3), donotXmit(4), revSigBit(5) } ACCESS read-write STATUS mandatory DESCRIPTION "This allows the node to pass A channel signalling bits through unchanged, or to invert / hold them at a given value for a CDP/CIP circuit line. It affects signalling bits in the transmit direction (eg. to the CPE / PABX). The value is given as one of the enumeration above which have following meaning: one(1) : Signalling bit is 1 zero(2) : Signalling bit is 0 xmitTransparent(3) : Transmit signalling bit transparently donotXmit(4) : Don't transmit signalling bit revSigBit(5) : Reverse/Inverse signalling bit. The default value is one. If the signalling is not used at all, the A B C and D bits have 1 1 0 1 values respectively. The initialization values is xmitTransparent(3)." ::= { voiceChannelEntry 15 } voiceChannelXmitSigBBit OBJECT-TYPE SYNTAX INTEGER { zero (1), one (2), xmitTransparent(3), donotXmit(4), revSigBit(5) } ACCESS read-write STATUS mandatory DESCRIPTION "This allows the node to pass B channel signalling bits through unchanged, or to invert / hold them at a given value for a CDP/CIP circuit line. It affects signalling bits in the transmit direction (eg. to the CPE / PABX). The value is given as one of the enumeration above which have following meaning: one(1) : Signalling bit is 1 zero(2) : Signalling bit is 0 xmitTransparent(3) : Transmit signalling bit transparently donotXmit(4) : Don't transmit signalling bit revSigBit(5) : Reverse/Inverse signalling bit. The default value is one. If the signalling is not used at all, the A B C and D bits have 1 1 0 1 values respectively. The initialization values is xmitTransparent(3)" ::= { voiceChannelEntry 16 } voiceChannelXmitSigCBit OBJECT-TYPE SYNTAX INTEGER { zero (1), one (2), xmitTransparent(3), donotXmit(4), revSigBit(5) } ACCESS read-write STATUS mandatory DESCRIPTION "This allows the node to pass C channel signalling bits through unchanged, or to invert / hold them at a given value for a CDP/CIP circuit line. It affects signalling bits in the transmit direction (eg. to the CPE / PABX). The value is given as one of the enumeration above which have following meaning: one(1) : Signalling bit is 1 zero(2) : Signalling bit is 0 xmitTransparent(3) : Transmit signalling bit transparently donotXmit(4) : Don't transmit signalling bit revSigBit(5) : Reverse/Inverse signalling bit. The default value is one. If the signalling is not used at all, the A B C and D bits have 1 1 0 1 values respectively. The initialization values is xmitTransparent(3)" ::= { voiceChannelEntry 17 } voiceChannelXmitSigDBit OBJECT-TYPE SYNTAX INTEGER { zero (1), one (2), xmitTransparent(3), donotXmit(4), revSigBit(5) } ACCESS read-write STATUS mandatory DESCRIPTION "This allows the node to pass D channel signalling bits through unchanged, or to invert / hold them at a given value for a CDP/CIP circuit line. It affects signalling bits in the transmit direction (eg. to the CPE / PABX). The value is given as one of the enumeration above which have following meaning: one(1) : Signalling bit is 1 zero(2) : Signalling bit is 0 xmitTransparent(3) : Transmit signalling bit transparently donotXmit(4) : Don't transmit signalling bit revSigBit(5) : Reverse/Inverse signalling bit. The default value is one. If the signalling is not used at all, the A B C and D bits have 1 1 0 1 values respectively. The initialization values is xmitTransparent(3)" ::= { voiceChannelEntry 18 } voiceChannelIfTypeName OBJECT-TYPE SYNTAX INTEGER { userConfig(1), unConfig(2), noSig(3), forceSig(4), twoWireENM(5), fourWireENM(6), fXO(7), fXSGS(8), fXSLS(9), dP0(10), dPT(11), rP0(12), rPT(13), sDP0(14), dX(15), eT0(16), pLAR(17), pLR(18), rD(19), r1(20), sSDC5A(21), r2Backward(22), r2Forward(23) } ACCESS read-write STATUS mandatory DESCRIPTION "It represents the interface type assigned to a channel. The following different types of interfaces are possbile: Number InterfaceType A B C D CondName 1 {User Config, U, U, N, N, a}, 2 {Unconfig, U, U, N, N, a}, 3 {No Sig, U, U, U, U, a}, 4 {Force Sig, U, U, N, N, a}, 5 {2W E&M, 0, X, N, N, a}, 6 {4W E&M, 0, X, N, N, a}, 7 {FXO, 1, 1, N, N, b}, 8 {FXS G/S, 0, 1, N, N, c}, 9 {FXS L/S, 0, X, N, N, d}, 10 {DPO, 0, X, N, N, a}, 11 {DPT, 0, X, N, N, a}, 12 {RPO, 0, X, N, N, a}, 13 {RPT, 0, X, N, N, a}, 14 {SDPO, 0, X, N, N, a}, 15 {DX, 0, X, N, N, a}, 16 {ETO, U, U, N, N, e}, 17 {PLAR, U, U, N, N, d}, 18 {PLR, 0, X, N, N, a}, 19 {RD, U, U, N, N, a}, 20 {R1 (SOCOTEL), 0, N, N, N, e}, 21 {SSDC5A, 1, 1, 0, 1, f}, 22 {R2 (backward), 1, 1, N, N, e}, 23 {R2 (forward), 1, 0, N, N, d} Where A B C D are the signalling bits corresponding to Onhook values having the following meanings: 0 meaning 0 1 meaning 1 X meaning donot Care U meaning unknown N meaning not used and the Conditioning templates can be any of a b c d e f types. If the IPX receives A B C D bits corresponding to the on-hook values, that channel is known to be on-hook. Otherwise that channel is known to be offhook. Each interface except for UserConfigured type has a pre-determined conditioning template associated with it which are of 5 different types apart from user configurable conditioning templates. Examples of valid values are any of the above interface number given above. If it is a userConfigured OR Forced Signalling (FCDSIG = 4) interface type then the following variables need to be supplied: voiceChannelIfOnhkABit voiceChannelIfOnhkBBit voiceChannelIfOnhkCBit voiceChannelIfOnhkDBit voiceChannelIfCondName. If any of the above variables are not provided with values then, the current values in the data base is retained.In all other cases the values are as shown in the table above. The interface type is ignored for 'D' type connections. The default values for a channel: InterfaceType A B C D CondName UnConfigured U U N N a. If a pre-defined Interface type is chosen in a SET, values for the other related objects should not be provided." ::= { voiceChannelEntry 19 } voiceChannelIfOnhkABit OBJECT-TYPE SYNTAX INTEGER { zero(1), one(2), donotCare(3), unKnown (4), notUsed(5) } ACCESS read-write STATUS mandatory DESCRIPTION "It represents the value of A signalling bit, for which the IPX shall recognize a on-hook condition. The default value is unKnown(4). The value corresponding to pre-defined Interface types have been given in the table in the 'Description' clause of the object voiceChannelIfTypeName. If the interface type is pre-defined type, value is not provided for this object." ::= { voiceChannelEntry 20 } voiceChannelIfOnhkBBit OBJECT-TYPE SYNTAX INTEGER { zero(1), one(2), donotCare(3), unKnown (4), notUsed(5) } ACCESS read-write STATUS mandatory DESCRIPTION "It represents the value of B signalling bit, for which the IPX shall recognize a on-hook condition. The default value is unKnown(4). The value corresponding to pre-defined Interface types have been given in the table in the 'Description' clause of the object voiceChannelIfTypeName. If the interface type is pre-defined type, value is not provided for this object." ::= { voiceChannelEntry 21 } voiceChannelIfOnhkCBit OBJECT-TYPE SYNTAX INTEGER { zero(1), one(2), donotCare(3), unKnown (4), notUsed(5) } ACCESS read-write STATUS mandatory DESCRIPTION "It represents the value of C signalling bit, for which the IPX shall recognize a on-hook condition. The default value is unKnown(4). The value corresponding to pre-defined Interface types have been given in the table in the 'Description' clause of the object voiceChannelIfTypeName. If the interface type is pre-defined type, value is not provided for this object." ::= { voiceChannelEntry 22 } voiceChannelIfOnhkDBit OBJECT-TYPE SYNTAX INTEGER { zero(1), one(2), donotCare(3), unKnown (4), notUsed(5) } ACCESS read-write STATUS mandatory DESCRIPTION "It represents the value of D signalling bit, for which the IPX shall recognize a on-hook condition. The default value is unKnown(4). The value corresponding to pre-defined Interface types have been given in the table in the 'Description' clause of the object voiceChannelIfTypeName. If the interface type is pre-defined type, value is not provided for this object." ::= { voiceChannelEntry 23 } voiceChannelIfCondIndex OBJECT-TYPE SYNTAX INTEGER (1..32) ACCESS read-write STATUS mandatory DESCRIPTION "It represents the name of one of the condition criterion templates defined in the voiceConditioningTable. The value corresponding to pre-defined interface Types have been given in the table in the 'Description' clause of the object voiceChannelIfTypeName. Currentely, only the pre-defined conditioning templates are supported. If the interface type is pre-defined type, value is not provided for this object." ::= { voiceChannelEntry 24 } voiceChannelEchoCancel OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This represents the integrated echo canceller channel parameters associated with the specified voice channel. By default it is disabled. If it has to be enabled from a disabled state then valued for following variables have to be supplied: Name Value Description voiceChannelEchoRtnLoss High/Low Set the echo return loss to High / Low. voiceChannelEchoTone Enable/ Enables or disables the Disable tone disabler. voiceChannelEchoConv Enable/ Enables or disables Disable convergence. voiceChannelEchoNlp Enable/ Enables or disables Disable non-linear processing. If any one of the variables are not specified, the previous value of that variable shall be retained. If the Echo Cancel is to be SET to disable, values for the related parameters are not allowed in the SET." ::= { voiceChannelEntry 25 } voiceChannelEchoRtnLoss OBJECT-TYPE SYNTAX INTEGER { low(1), high(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This represents the Echo Return Loss if the echo canceller is enabled. The default value is High(2). If the Echo Cancel is to be SET to disable, values for the related parameters are not allowed in the SET." ::= { voiceChannelEntry 26 } voiceChannelEchoTone OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This represents whether the Tone disabler is enabled. The default value is Enable(1). If the Echo Cancel is to be SET to disable, values for the related parameters are not allowed in the SET." ::= { voiceChannelEntry 27 } voiceChannelEchoConv OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This represents whether the Echo Convergence is enabled. The default value is Enable(1). If the Echo Cancel is to be SET to disable, values for the related parameters are not allowed in the SET." ::= { voiceChannelEntry 28 } voiceChannelEchoNlp OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This represents whether the NonLinear processing is enabled. The default value is Enable(1). If the Echo Cancel is to be SET to disable, values for the related parameters are not allowed in the SET." ::= { voiceChannelEntry 29 } voiceChannelInGain OBJECT-TYPE SYNTAX INTEGER (0..14) ACCESS read-write STATUS mandatory DESCRIPTION "This variable represents the amount of gain inserted at the receiver side of a CDP / CIP circuit line on voice connections. The gain is specified in decibels to be assigned to the channel. The gain can be configured between +6 dB and -8 dB. By default it is zero." ::= { voiceChannelEntry 30 } voiceChannelOutGain OBJECT-TYPE SYNTAX INTEGER (0..14) ACCESS read-write STATUS mandatory DESCRIPTION "This variable represents the amount of gain inserted at the transmit side of a CDP / CIP circuit line on voice connections. The gain is specified in decibels to be assigned to the channel. The gain can be configured between +6 dB and -8 dB. By default it is zero." ::= { voiceChannelEntry 31 } voiceChannelUtil OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-write STATUS mandatory DESCRIPTION "Represents the percentage of utilization of this channel. This object informs the system software of the expected utilization rate of connections with traffic depdendent compression algorithm. For voice connections with VAD. Acceptable values are in the range of 0 to 100. The default value for voice is 40." ::= { voiceChannelEntry 32 } -- -- This object is used for creating PVCs (connections). The following -- steps are required for creating PVCs (this example creates a -- frame relay PVC): -- -- 1) Obtain the current value of connNextEndptIndex. -- 2) Create a new entry in the frEndptTable: -- a. Set frEndptAdminStatus to create using index value -- obtained from connNextEndptIndex. -- b. Set the values of frEndptDesc and frOtherEndptDesc -- appropriately. For example to creat a from NodeA in domain -- D1 using Frame Relay end-point 12.1.100 to NodeB in domain D2 -- with Frame Relay end-point 4.2.100: -- Set frEndptDesc to string 12.1.100 -- Set frOtherEndptDesc to string D2.NodeB.4.2.100 -- c. Optionally Set the values of the input and output bandwidth -- parameters. -- d. Optionally Set the values of the other PVC options. -- 3) Issue a management protocol SET operation for the newly built -- entry. -- -- Once complete, a new row in the frEndptTable will exist with -- the value obtained from connNextEndptIndex as the INDEX, and a new -- row in the connTable will exist. The connTable row is used to -- manipulate the state of the connection, obtain current status of -- the connection, and to obtain routing information about the connection. -- -- To delete the connection, modify the frEndptAdminStatus object in the -- corresponding end-point to "delete", and perform a management protocol -- SET operation on the entry. -- connNextEndptIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object contains an appropriate value to be used when creating entries in the connection specific end-point tables (e.g. frEndptTable). A value of minus one (-1) indicates that no unassigned entries are available. To obtain the connNextEndptIndex value for a new entry, the manager issues a management protocol retrieval operation to obtain the current value of this object. After each retrieval, the agent should modify the value to the next unassigned index." --DEFAULT get-function get-conn-nextendptindex ::= { switchConnection 1 } -- This object contains the value of the request id for the newest -- entry in the error status table. Many management applications -- have no knowledge of the request ids used by the SNMP engine. -- These applications can get the value of this object and then -- use it to retrieve the error status for the last SET operation. errStatusLastIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS obsolete DESCRIPTION "If at least one entry exists in the error status table for the given manager, the value of this object contains the index corresponding to the last entry. If no entry exists in the error status table for the given manager the value of this object is -1." --DEFAULT get-function get-err-lastindex ::= { switchConnection 2 } -- -- The following table is used to maintain status information about -- SNMP SET requests from a Manager. When an SNMP SET completes, an -- entry is created. In addition to successful status, the manager -- is provided information associated with any failed requests. This -- table is indexed by request ID. The request Id is the SNMP PDU -- identifier associated with the failed request. -- -- Currently a limit of 10 entries are imposed on this table. Each -- manager is allowed to access it's own table. Individual manager -- access is determined by IP address. -- errStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF ErrStatusTableEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "A List of Error Statuses for a given SNMP Manager" --DEFAULT test-function test-errtable --DEFAULT next-function next-errtable --DEFAULT get-function get-errtable-%t ::= { switchConnection 3 } errStatusTableEntry OBJECT-TYPE SYNTAX ErrStatusTableEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "A General Error Status Entry." INDEX { errReqId } ::= { errStatusTable 1 } ErrStatusTableEntry ::= SEQUENCE { errReqId INTEGER, errCode INTEGER, errStatusDesc DisplayString } errReqId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object contains the PDU request ID associated with the error." ::= { errStatusTableEntry 1 } errCode OBJECT-TYPE SYNTAX INTEGER { success(1), existErr(2), syntaxErr(3), resourceErr(4), databaseLocked(5), otherErr(6), wrongType(7), wrongLength(8), wrongEncoding(9), wrongValue(10), noCreation(11), inconsistentValue(12), resourceUnavailable(13), commitFailed(14), undoFailed(15), authorizationError(16), notWritable(17), inconsistentName(18), featureDisabled(19), m32Problem(20), sarProblem(21), bnmProblem(22), ascUpdFailed(23), lineEnabled(24), lineDisabled(25), lmMismatch(26), lineHasPorts(27), portEnabled(28), portDisable(29), portHasChan(30), chanEnabled(31), chanDisabled(32), dlciEnabled(33), dlciDisabled(34) } ACCESS read-only STATUS mandatory DESCRIPTION "This object contains an error status code used by the manager to take automated corrective actions when requests encounter failures. If no error is encountered, a successful status is provided." ::= { errStatusTableEntry 2 } errStatusDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This object contains error status information for failed SETS to one or more objects in frEndptTable and/or vcTable. This object is updated only on failed SETS. Since the SNMP standard allows only limited number of error status returns, the managers can retrieve this variable to get additional information on a failed SET. Typically this object will contain information specifiying date, type of operation (SET or GET), current SNMP table (connTable, frEndptTable,... etc) and additional error information." ::= { errStatusTableEntry 3 } -- -- This is the table describing all the connections associated with -- this managed entity. The endpoints (virtual circuits) related to -- these connections are defined in connection type-specific tables. -- -- This table contains entries for existing connections. These -- entries can be viewed for the purpose of obtaining current information -- about the managed entities connections: -- -- 1) connLclEndptDesc describes the local end-point for the connection. -- Via this description one can obtain local domain, nodename, and -- connection specific identifiers (e.g. slot, port, and address). -- 2) connRmtEndptDesc describes the remote end-point for the connection. -- Via this description one can obtain remote domain, nodename, and -- connection specific identifiers (e.g. slot, port, and address). -- 3) connOeIndex allows a manager to obtain information about the -- connection from the remote node viewpoint. This information -- can be obtained by querying the remote node's connTable using -- connOeIndex as the key INDEX. -- 4) connAdminStatus allows the connection to have it's state -- changed from up to down, modify it's class of service, or -- configure the preffered route of the connection. -- 5) connOperStatus contains the current status of the connection. -- If the status is "failed", connNoRouteFoundFailure, connBumpFailure, -- connEndPointFailure, and connTestFailure give more details about the -- failure. -- 6) connFirstEndptPtr is an object identifier pointer to obtain a row -- in the end-point table that describes the local virtual circuit -- end-point. -- Using the connType object, it is known what type of table this is -- pointing to. For example, this may point to an entry in the -- frEndptTable for connections with vcType of frame-relay. -- It is through the end-point specific tables that more -- information such as configuration and statistics can be obtained. -- Configuration of the connection is accomplished via modification -- of the entry in the end-point specific table. For bundled or grouped -- connections, this object identifier points to the first end-point -- of the bundle or group. -- 7) connCurrRouteDesc describes the current route being used by this -- connection. All hops of the route are specified. -- 8) connPrefRouteDesc describes the preferred route being used by this -- connection. All hops of the route are specified. -- 9) connMstOSpacePkts provides the minimum packet load available on the -- current path of this connection in master -> slave direction. -- 9.1)connMstOSpaceCells provides the minimum cell load available on the -- current path of this connection in master -> slave direction. -- 10) connMstOSpaceBdaCmax provides the minimum BData A Cmax available on -- current path of this connection in master -> slave direction. -- 11) connMstOSpaceBdbCmax provides the minimum BData B Cmax available on -- current path of this connection in master -> slave direction. -- 12) connSlvOSpacePkts provides the minimum packet load available on the -- current path of this connection in slave -> master direction. -- 12.1)connSlvOSpaceCells provides the minimum cell load available on the -- current path of this connection in slave -> master direction. -- 13) connSlvOSpaceBdaCmax provides the minimum BData A Cmax available on -- current path of this connection in slave -> master direction. -- 14) connSlvOSpaceBdbCmax provides the minimum BData B Cmax available on -- current path of this connection in slave -> master direction. -- connTable OBJECT-TYPE SYNTAX SEQUENCE OF ConnTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A List of Connection Virtual Circuit Entries" --DEFAULT test-function test-conntable --DEFAULT next-function next-conntable --DEFAULT get-function get-conntable-%t ::= { switchConnection 4 } connTableEntry OBJECT-TYPE SYNTAX ConnTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A General Connection Entry" INDEX { connIndex } ::= { connTable 1 } ConnTableEntry ::= SEQUENCE { connIndex INTEGER, connLclEndptDesc DisplayString, connType INTEGER, connOeIndex INTEGER, connRmtEndptDesc DisplayString, connMasterFlag INTEGER, connClassOfService INTEGER, connGroupFlag INTEGER, connAdminStatus INTEGER, connOperStatus INTEGER, connNoRouteFoundFailure INTEGER, connBumpFailure INTEGER, connFirstEndptPtr OBJECT IDENTIFIER, connCurrRouteDesc DisplayString, connPrefRouteDesc DisplayString, connMstOSpacePkts INTEGER, connMstOSpaceCells INTEGER, connMstOSpaceBdaCmax INTEGER, connMstOSpaceBdbCmax INTEGER, connSlvOSpacePkts INTEGER, connSlvOSpaceCells INTEGER, connSlvOSpaceBdaCmax INTEGER, connSlvOSpaceBdbCmax INTEGER, connIcaRTD INTEGER, connGroupDesc DisplayString } connIndex OBJECT-TYPE SYNTAX INTEGER (0..1999) ACCESS read-only STATUS mandatory DESCRIPTION "Connection Table Index for this connection." ::= { connTableEntry 1 } connLclEndptDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Description for Local VC end-point. Contains information about the domain, nodename, slot, port, and address value for the end-point. For example, D1.Node1.12.1.100.200, is a valid description. For Frame Relay groups, the domain, remote nodename, and groupid are given, for example D1.Node2.1 is valid." ::= { connTableEntry 2 } connType OBJECT-TYPE SYNTAX INTEGER { frameRelay(1), atf(2), atm(3), voice(4), unknown(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Connection type" ::= { connTableEntry 3 } connOeIndex OBJECT-TYPE SYNTAX INTEGER (0..1999) ACCESS read-only STATUS mandatory DESCRIPTION "Index into remote node's connTable for this connection end-point." ::= { connTableEntry 4 } connRmtEndptDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Description for Remote VC end-point. Contains information about the domain, nodename, slot, port, and address value for the end-point. For example, D2.Node2.10.1.100.200, is a valid description. This object contains no information for Frame Relay connection groups." ::= { connTableEntry 5 } connMasterFlag OBJECT-TYPE SYNTAX INTEGER { false(1), true(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Specifies whether this end-point is the owner of the connection." ::= { connTableEntry 6 } connClassOfService OBJECT-TYPE SYNTAX INTEGER (0..15) ACCESS read-write STATUS mandatory DESCRIPTION "A class of service for this connection. The lower the class value, the higher the routing priority of the connection." ::= { connTableEntry 7 } connGroupFlag OBJECT-TYPE SYNTAX INTEGER { false(1), true(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Specifies whether this is a grouped connection. In the grouped connection case, the connFirstEndptPtr object is a pointer to a list of end-points in this group." ::= { connTableEntry 8 } connAdminStatus OBJECT-TYPE SYNTAX INTEGER { up(1), down(2), modify(3), writeOnly(4), createGroup(5), deleteGroup(6) } ACCESS read-write STATUS mandatory DESCRIPTION "User requested state for connection. A user can change the state of the connection to up or down. The user is also allowed to modify the connections class of service or preferred route. The connOperStatus object maintains the current status of the connection." ::= { connTableEntry 9 } connOperStatus OBJECT-TYPE SYNTAX INTEGER { ok(1), okPendingDown(2), down(3), failed(4), okPendingRoute(5), unknown(6) } ACCESS read-only STATUS mandatory DESCRIPTION "Actual state of the connection. If the state is failed, then look to the objects connNoRouteFoundFailure, and connBumpFailure to determine reason for failure." ::= { connTableEntry 10 } connNoRouteFoundFailure OBJECT-TYPE SYNTAX INTEGER { false(1), true(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Connection is failed is because no route to the remote end-point could be found." ::= { connTableEntry 11 } connBumpFailure OBJECT-TYPE SYNTAX INTEGER { false(1), true(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Connection is failed because of insufficient bandwidth to route to the remote end-point. This may have also been caused because a higher priority connection took this connections bandwidth. A higher priority connection is one with the lowest class of service (COS)." ::= { connTableEntry 12 } connFirstEndptPtr OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "Pointer to end-point specific information. Using this pointer the user can obtain configuration and statistical information about the connection. Specifically, this object identifier specifies the MIB tree identification of the first column of the appropriate end-point table row." ::= { connTableEntry 13 } connCurrRouteDesc OBJECT-TYPE SYNTAX DisplayString ( SIZE (0..255) ) ACCESS read-only STATUS mandatory DESCRIPTION "Descriptor of the current route (all hops specified). Descriptor gives information about the domain, nodename, slot, and possibly a port for each hop in the route. For example, Node1 15--15Node2 is a valid route specifying a terrestrial link between Node1 slot 15 and Node2 slot 15. Inter-domain connection's routes will append the remote domain and nodename of the terminating endpoint." ::= { connTableEntry 14 } connPrefRouteDesc OBJECT-TYPE SYNTAX DisplayString ( SIZE (0..255) ) ACCESS read-write STATUS mandatory DESCRIPTION "Descriptor of the preferred route (all hops specified). Descriptor gives information about the domain, nodename, slot, and possibly a port for each hop in the route. For example, Node1 15--15Node2 is a valid route specifying a terrestrial link between Node1 slot 15 and Node2 slot 15. While doing a SET operation the following general format for specifying a preferred route should be used: (.[.0])* - (.)* - Some more valid descriptions are: 1) Node1.15.1 - Node2.13.1 - Node3 2) Node1.15.1-Node2.13.1-Node3 3) Node1.15 - Node2.12 - Node3.15 - Node4 4) Node1.15.0 - Node2.12.0 - Node3.15.0 - Node4 NOTE: a> (...)* notation means the description inside parenthesis may repeat any number of times, only limited by the total length which is 255 and the [...] notation signifies that it is optional. b> 1) & 2) are equivalent so are 3) & 4). c> Even GET preferred route description will be made consistent with that of SET operation in the future releases. d> An empty string (null or string of blank spaces) will clear the pref route description equivalent to delete pref route." ::= { connTableEntry 15 } connMstOSpacePkts OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the minimum packet load available on the current path of this connection in master->slave direction. This variable is determined by comparing available bandwidth on every trunk on which the connection is currently routed and reporting the minimum available bandwidth. For interdomain connections this value represents available bandwidth through all domains. This variable is meaningful for routed connections only. These values are returned in packets per second." ::= { connTableEntry 16 } connMstOSpaceCells OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the minimum cell load available on the current path of this connection in master->slave direction. This variable is determined by comparing available bandwidth on every trunk on which the connection is currently routed and reporting the minimum available bandwidth. For interdomain connections this value represents available bandwidth through all domains. This variable is meaningful for routed connections only. These values are returned in cells per second." ::= { connTableEntry 17 } connMstOSpaceBdaCmax OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the minimum BData A Cmax available on the current path of this connection in master->slave direction. This variable is determined by comparing available BData A Cmax on every trunk on which the connection is currently routed and reporting the minumim available. For interdomain connections this value represents available BData A Cmax through all domains. This variable is meaningful for routed connections only. These values are returned in bytes." ::= { connTableEntry 18 } connMstOSpaceBdbCmax OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the minimum BData B Cmax available on the current path of this connection in master->slave direction. This variable is determined by comparing available BData B Cmax on every trunk on which the connection is currently routed and reporting the minumim available. For interdomain connections this value represents available BData B Cmax through all domains. This variable is meaningful for routed connections only. These values are returned in bytes." ::= { connTableEntry 19 } connSlvOSpacePkts OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the minimum packet load available on the current path of this connection in slave->master direction. This variable is determined by comparing available bandwidth on every trunk on which the connection is currently routed and reporting the minumim available bandwidth. For interdomain connections this value represents available bandwidth through all domains. This variable is meaningful for routed connections only. These values are returned in packets per second." ::= { connTableEntry 20 } connSlvOSpaceCells OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the minimum cell load available on the current path of this connection in slave->master direction. This variable is determined by comparing available bandwidth on every trunk on which the connection is currently routed and reporting the minumim available bandwidth. For interdomain connections this value represents available bandwidth through all domains. This variable is meaningful for routed connections only. These values are returned in cells per second." ::= { connTableEntry 21 } connSlvOSpaceBdaCmax OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the minimum BData A Cmax available on the current path of this connection in slave->master direction. This variable is determined by comparing available BData A Cmax on every trunk on which the connection is currently routed and reporting the minumim available. For interdomain connections this value represents available BData A Cmax through all domains. This variable is meaningful for routed connections only. These values are returned in bytes." ::= { connTableEntry 22 } connSlvOSpaceBdbCmax OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the minimum BData B Cmax available on the current path of this connection in slave->master direction. This variable is determined by comparing available BData B Cmax on every trunk on which the connection is currently routed and reporting the minumim available. For interdomain connections this value represents available BData B Cmax through all domains. This variable is meaningful for routed connections only. These values are returned in bytes." ::= { connTableEntry 23 } connIcaRTD OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is the calculated round trip delay (measured in milliseconds) of this connection. This object is calculated for Foresight connections only. (xxEndptEnableFST object value is true)." ::= { connTableEntry 24 } connGroupDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Description for Group identifier. This string describes the connection group name. The format of the group name is domain.node-name.grp-number (Example, D1.node1.1). The varaible connIndex needs to have a special value of 65535 when creating a group. The group number and the domain are optional." ::= { connTableEntry 25 } -- -- This table defines Frame Relay connection end-point configuration. -- Each connection (virtual circuit or PVC) end-point describes the -- particular characteristics of the end-point. Such information -- as local and remote end-point description, class of service, input -- and output bandwidth parameters, special PVC options, and PVC -- statistics are maintained in the end-point. Also, mechanisms for -- determining the connection information associated with this end-point, -- the next end-point of a bundle or group, and a means for creating -- or deleting this end-point are included. -- frEndptTable OBJECT-TYPE SYNTAX SEQUENCE OF FrEndptEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Frame Relay End-Point Configuration table. This table is used to model a Frame Relay end-point. The table contains the configuration parameters required to create and configure a Frame Relay end-point." --DEFAULT test-function test-frendpttable --DEFAULT next-function next-frendpttable --DEFAULT get-function get-frendpttable-%t --DEFAULT view-mask IPX-VIEW ::= { switchConnection 5 } frEndptEntry OBJECT-TYPE SYNTAX FrEndptEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Frame Relay End-point Configuration table." INDEX { frEndptIndex } ::= { frEndptTable 1 } FrEndptEntry ::= SEQUENCE { frEndptIndex INTEGER, frEndptDesc DisplayString, frOtherEndptIndex INTEGER, frOtherEndptDesc DisplayString, frEndptAdminStatus INTEGER, frEndptOperStatus INTEGER, frNoRouteFoundFailure INTEGER, frBumpFailure INTEGER, frEndPointFailure INTEGER, frTestFailure INTEGER, frConnPtr OBJECT IDENTIFIER, frNextPtr OBJECT IDENTIFIER, frNextOnPortPtr OBJECT IDENTIFIER, frEndptConnDesc DisplayString, frEndptTrkAvoidType INTEGER, frEndptTrkAvoidZCS INTEGER, frEndptSubType INTEGER, frEndptBWClass INTEGER, frEndptMIR INTEGER, frEndptCIR INTEGER, frEndptBc INTEGER, frEndptBe INTEGER, frEndptVcQSize INTEGER, frEndptPIR INTEGER, frEndptCMAX INTEGER, frEndptEcnQSize INTEGER, frEndptQIR INTEGER, frEndptPercUtil INTEGER, frEndptOeMIR INTEGER, frEndptOeCIR INTEGER, frEndptOeBc INTEGER, frEndptOeBe INTEGER, frEndptOeVcQSize INTEGER, frEndptOePIR INTEGER, frEndptOeCMAX INTEGER, frEndptOeEcnQSize INTEGER, frEndptOeQIR INTEGER, frEndptOePercUtil INTEGER, frEndptEnableFST INTEGER, frEndptConnPrio INTEGER, frEndptGroupFlag INTEGER, frEndptLocLpbkState INTEGER, frEndptLocRmtLpbkState INTEGER, frEndptLpbkStatus INTEGER, frEndptTestType INTEGER, frEndptRtdTestDelay INTEGER, frEndptGroupDesc DisplayString } frEndptIndex OBJECT-TYPE SYNTAX INTEGER (0..2047) ACCESS read-only STATUS mandatory DESCRIPTION "Index into table for this end-point. Although only 1024 endpoints may exist on a node, 2048 possible index values exist to support DAX (intra-node) connections." ::= { frEndptEntry 1 } frEndptDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "String describing this end-point. Contains information about the domain, nodename, slot, port, and DLCI for the end-point. For example, D1.Node1.12.1.100, is a valid description. Domain and nodename need not be given but slot, port, and DLCI values must exist; 12.1.100 is valid." ::= { frEndptEntry 2 } frOtherEndptIndex OBJECT-TYPE SYNTAX INTEGER (0..2047) ACCESS read-only STATUS mandatory DESCRIPTION "Index into remote node's frEndptTable for this PVC end-point. For DAX (intra-node) connections, this index is associated with the local node and will be in the range of 1024 to 2047." ::= { frEndptEntry 3 } frOtherEndptDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "String describing the remote end-point. Contains information about the domain, nodename, slot, port, and DLCI for the end-point. For example, D2.Node2.10.1.100, is a valid description. Nodename, slot, port, and DLCI values must exist; Node2.10.1.100 is valid." ::= { frEndptEntry 4 } frEndptAdminStatus OBJECT-TYPE SYNTAX INTEGER { create(1), delete(2), modify(3), test(4), writeOnly(5) } ACCESS read-write STATUS mandatory DESCRIPTION "User requested state for end-point table row. A user can create this VC or delete this VC by setting this object appropriately. If the end-point is to be modified, set this object identifier to be modify. The user also has the capability to test a particular object. For this capability, the user must set this value to test." ::= { frEndptEntry 5 } frEndptOperStatus OBJECT-TYPE SYNTAX INTEGER { ok(1), okPendingDown(2), down(3), failed(4), inTest(5), okPendingRoute(6), okPendingDelete(7), looped(8), unknown(9) } ACCESS read-only STATUS mandatory DESCRIPTION "Actual state of the end-point. If the state is failed, then look to the objects frNoRouteFoundFailure, frBumpFailure, frEndPointFailure, and frTestFailure to determine reason for failure." ::= { frEndptEntry 6 } frNoRouteFoundFailure OBJECT-TYPE SYNTAX INTEGER { false(1), true(2) } ACCESS read-only STATUS mandatory DESCRIPTION "End-point is failed is because no route to the remote end-point could be found." ::= { frEndptEntry 7 } frBumpFailure OBJECT-TYPE SYNTAX INTEGER { false(1), true(2) } ACCESS read-only STATUS mandatory DESCRIPTION "End-point is failed because of insufficient bandwidth to route to the remote end-point. This may have also been caused because a higher priority connection took this end-point's bandwidth. A higher priority connection is one with the lowest class of service (COS)." ::= { frEndptEntry 8 } frEndPointFailure OBJECT-TYPE SYNTAX INTEGER { false(1), true(2) } ACCESS read-only STATUS mandatory DESCRIPTION "End-point is failed because of a remote end-point failure. The remote end-point is on a node that resides in another domain making the connection an inter-domain connection." ::= { frEndptEntry 9 } frTestFailure OBJECT-TYPE SYNTAX INTEGER { false(1), true(2) } ACCESS read-only STATUS mandatory DESCRIPTION "End-point is failed because of the failure of a connection test." ::= { frEndptEntry 10 } frConnPtr OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "Pointer to general connection information. Using this pointer the user can obtain connection status, and routing information. Specifically, this is an object identifier specifying the first column of the appropriate row in the connTable." ::= { frEndptEntry 11 } frNextPtr OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "Pointer to next end-point information. This allows logical sets of end-points to be linked up. For example, the end-points associated with a bundle or group. Specifically, this is an object identifier specifying the first column of the appropriate row in the frEndptTable." ::= { frEndptEntry 12 } frNextOnPortPtr OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "Pointer to next end-point information for the port associated with this end-point. For example, using this pointer all frame relay end-points on a given slot.port can be determined. Specifically, this is an object identifier specifying the first column of the appropriate row in the frEndptTable." ::= { frEndptEntry 13 } frEndptConnDesc OBJECT-TYPE SYNTAX DisplayString ( SIZE (0..20) ) ACCESS read-write STATUS mandatory DESCRIPTION "A string that has been defined for the connection to give a more descriptive name. Connections can be given clear text names in order to make them more human readable." ::= { frEndptEntry 14 } frEndptTrkAvoidType OBJECT-TYPE SYNTAX INTEGER { none(1), satellite(2), terrestrial(3) } ACCESS read-write STATUS mandatory DESCRIPTION "User selectable types of trunks to avoid for the transfer of FRP data. Current choices are to avoid satellite links, terrestrial links, or to not avoid any specific type of link. This object is optional during the creation of the endpoint." ::= { frEndptEntry 15 } frEndptTrkAvoidZCS OBJECT-TYPE SYNTAX INTEGER { false(1), true(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Flag to force the connection to avoid trunks with zero code suppression (ZCS). This object is optional during the creation of the endpoint." ::= { frEndptEntry 16 } frEndptSubType OBJECT-TYPE SYNTAX INTEGER { frameRelay(1), atf(2), unknown(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay endpoint subtype object." ::= { frEndptEntry 17 } frEndptBWClass OBJECT-TYPE SYNTAX INTEGER (1..10) ACCESS read-write STATUS mandatory DESCRIPTION "User selectable connection class which defines the operating parameters for the connection. Any or all of these parameters can be overridden by specifying the bandwidth parameters directly. This object is required during the creation of an endpoint." ::= { frEndptEntry 18 } frEndptMIR OBJECT-TYPE SYNTAX INTEGER (2400..2048000) ACCESS read-write STATUS mandatory DESCRIPTION "The minimum transmit bandwidth (MIR) parameter (in 100s of bits per second) for this end-point. During creation of an endpoint, this object is required if no class index is provided. This is because the default values of bandwidth parameters not provided are derived from this object." ::= { frEndptEntry 19 } frEndptCIR OBJECT-TYPE SYNTAX INTEGER (2400..2048000) ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is equal to the committed information rate (CIR) parameter (in 100s of bits per second) for this end-point. This value will be defaulted to the provided MIR during an endpoint create." ::= { frEndptEntry 20 } frEndptBc OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is equal to the committed burst size (Bc) parameter (in bytes) for this end-point. This parameter is entered instead of the frEndptVcQSize parameter. If both the Bc and VcQSize are provided, the values are tested for compatibility." ::= { frEndptEntry 21 } frEndptBe OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is equal to the excess burst size (Be) parameter (in bytes) for this end-point. This parameter is entered instead of the frEndptPIR parameter. If both the Be and the PIR are provided, the values are tested for compatibility." ::= { frEndptEntry 22 } frEndptVcQSize OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the maximum queue depth (in bytes) for this end-point. This parameter is entered instead of the frEndptBc parameter. If both the VcQSize and the Bc are provided, the values are tested for compatibility." ::= { frEndptEntry 23 } frEndptPIR OBJECT-TYPE SYNTAX INTEGER (2400..2048000) ACCESS read-write STATUS mandatory DESCRIPTION "The peak transmit bandwidth (PIR) parameter (in 100s of bits per second) for this end-point. This parameter is entered instead of the frEndptBe parameter. This value defaults to the current port speed of the associated interface." ::= { frEndptEntry 24 } frEndptCMAX OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "The maximum credits that can be accrued for this end-point." ::= { frEndptEntry 25 } frEndptEcnQSize OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The threshold setting used by the explicit congestion notification feature for this end-point's transmit queue. This value is specified in bytes. When the frEndptVcQSize value exceeds this value then the FECN bit will be set in all frames transmitted to the remote end-point." ::= { frEndptEntry 26 } frEndptQIR OBJECT-TYPE SYNTAX INTEGER (2400..2048000) ACCESS read-write STATUS mandatory DESCRIPTION "The transmit quiescent information rate (QIR) parameter (in 100s of bits per second) for this end-point. This value can range between the MIR and PIR values and must be between 2400 and 2048000. This parameter has meaning only if the frEndptEnableFST parameter is set to true." ::= { frEndptEntry 27 } frEndptPercUtil OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is equal to the channel percentage utilization setting for this end-point. This is the expected long-term utilization of the channel by this end-point." ::= { frEndptEntry 28 } frEndptOeMIR OBJECT-TYPE SYNTAX INTEGER (2400..2048000) ACCESS read-write STATUS mandatory DESCRIPTION "The minimum receive bandwidth (MIR) parameter (in 100s of bits per second) for the other end-point. This parameter is actually the frEndptMIR parameter for the remote end-point. During creation of an endpoint, this object is required if no class index is provided. This is because the default values of bandwidth parameters not provided are derived from this object." ::= { frEndptEntry 29 } frEndptOeCIR OBJECT-TYPE SYNTAX INTEGER (2400..2048000) ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is equal to the committed information rate (CIR) parameter (in 100s of bits per second) for the other end-point. This parameter is actually the frEndptCIR parameter for the remote end-point." ::= { frEndptEntry 30 } frEndptOeBc OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is equal to the committed burst size (Bc) parameter (in bytes) for the end-point. This parameter is entered instead of the frEndptOeVcQSize parameter. This parameter is actually the frEndptBc parameter for the remote end-point. Since this value is calculated at the remote end based on the BW parameters unaccessible by the local agent during the varbind validation, the value specifed in the success SET response MAY NOT be its end value. The NMS is advised to GET this parameter again to confirm its actual value. Note: While modifying the value of this object it should be in the range 1..65535." ::= { frEndptEntry 31 } frEndptOeBe OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is equal to the excess burst size (Be) parameter (in bytes) for the other end-point This parameter is entered instead of the frEndptOePIR parameter. This parameter is actually the frEndptBe parameter for the remote end-point. Since this value is calculated at the remote end based on the BW parameters unaccessible by the local agent during the varbind validation, the value specifed in the success SET response MAY NOT be its end value. The NMS is advised to GET this parameter again to confirm its actual value." ::= { frEndptEntry 32 } frEndptOeVcQSize OBJECT-TYPE SYNTAX INTEGER (1..3072000) ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the maximum queue depth (in bytes) for this end-point. This parameter is entered instead of the frEndptOeBc parameter. This parameter is actually the frEndptVcQSize parameter for the remote end-point. Since this value is calculated at the remote end based on the BW parameters unaccessible by the local agent during the varbind validation, the value specifed in the success SET response MAY NOT be its end value. The NMS is advised to GET this parameter again to confirm its actual value." ::= { frEndptEntry 33 } frEndptOePIR OBJECT-TYPE SYNTAX INTEGER (2400..2048000) ACCESS read-write STATUS mandatory DESCRIPTION "The peak receive bandwidth (PIR) parameter (in 100s of bits per second) for the other end-point This parameter is entered instead of the frEndptOeBe parameter. This parameter is actually the frEndptPIR parameter for the remote end-point. This value defaults to the current port speed of the associated interface. Since this value is calculated at the remote end based on the BW parameters unaccessible by the local agent during the varbind validation, the value specifed in the success SET response MAY NOT be its end value. The NMS is advised to GET this parameter again to confirm its actual value." ::= { frEndptEntry 34 } frEndptOeCMAX OBJECT-TYPE SYNTAX INTEGER (1..57600) ACCESS read-write STATUS mandatory DESCRIPTION "The maximum credits that can be accrued for the other end-point. This parameter is actually the frEndptCMAX parameter for the remote end-point." ::= { frEndptEntry 35 } frEndptOeEcnQSize OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The threshold setting used by the explicit congestion notification feature for the other end-point's receive queue. This value is specified in bytes. When the frpVCEndptOeVcQSize value exceeds this value then the BECN bit will be set in all frames transmitted to Frame Relay Service User. This parameter is actually the frEndptEcnQSize parameter for the remote end-point." ::= { frEndptEntry 36 } frEndptOeQIR OBJECT-TYPE SYNTAX INTEGER (2400..2048000) ACCESS read-write STATUS mandatory DESCRIPTION "The receive quiescent information rate (QIR) parameter (in 100s of bits per second) for the other end-point. This value can range between the MIR and PIR values and must be between 2400 and 2048000. This parameter has meaning only if the frEndptEnableFST parameter is set to true. This parameter is actually the frEndptQIR parameter for the remote end-point." ::= { frEndptEntry 37 } frEndptOePercUtil OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is equal to the channel percentage utilization setting for the other end-point. This is the expected long-term utilization of the channel by the other end-point. This parameter is actually the frEndptPercUtil parameter for the remote end-point." ::= { frEndptEntry 38 } frEndptEnableFST OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object determines whether or not the ForeSight option is being used for this . If set to false, then ForeSight is not used, and if true then ForeSight will be used." ::= { frEndptEntry 39 } frEndptConnPrio OBJECT-TYPE SYNTAX INTEGER { low(1), high(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object determines the priority that is given to the data carried by this . If set to low, then the data is given the standard priority, and if set to high, the data will be given a higher priority. Higher priority data is placed at the beginning of the port's queues." ::= { frEndptEntry 40 } frEndptGroupFlag OBJECT-TYPE SYNTAX INTEGER { false(1), true(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Specifies whether this is a grouped connection. Note that MIB object connGroupFlag provides grouping information about all the connections using that connTable entry whereas this object provides same information for this end point." ::= { frEndptEntry 41 } frEndptLocLpbkState OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the Local Loopback State the user would like to set for the endpoint." ::= { frEndptEntry 42 } frEndptLocRmtLpbkState OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the Local-Remote Loopback State the user would like to set for the endpoint." ::= { frEndptEntry 43 } frEndptLpbkStatus OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the current Loopback State of the endpoint. The value returned from this object is a bitmap of the current loopback states which the endpoint has configured. There currently are 16 loopback states an endpoint may have configured. If NO LOOPBACK is configured, the agent will return -1. The bitmap is defined as follows: LP-RMT-RMT 0 /* Remote nodes remote muxbus loopback */ LP-RMT-TST 1 /* Remote nodes tstcon loopback */ LP-LOC-RMT 2 /* Local nodes remoet muxbus loopback */ LP-LOC-TST 3 /* Local nodes tstcon loopback */ LP-LOC-LOC 4 /* Local nodes local muxbus loopback */ LP-LOC-PORT 5 /* Local nodes port loopback */ LP-LOC-TPORT 6 /* Local nodes port test loopback */ LP-RMT-LOC 7 /* Remote nodes local muxbus loopback */ LP-RMT-PORT 8 /* Remote nodes port loopback */ LP-RMT-TPORT 9 /* Remote nodes port test looback */ LP-LOC-CSU 10 /* Local DDS network requested CSU loopback */ LP-RMT-CSU 11 /* Remote DDS network requested CSU loopback */ LP-LOC-DSU 12 /* Local DDS network requested DSU loopback */ LP-RMT-DSU 13 /* Remote DDS network requested DSU loopback */ LP-LOC-EXT 14 /* Local DDS external loopback */ LP-RMT-EXT 15 /* Remote DDS external loopback */ " ::= { frEndptEntry 44 } frEndptTestType OBJECT-TYPE SYNTAX INTEGER { test(1), testDelay(2), testNoLoop(3), testDelayNoLoop(4), writeOnly(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the type of test the user would like to conduct on this endpoint. There are currently two types of tests. Test will exercise continuity, while TestDelay will calculate the delay incurred on the connection. The result of the TestDelay may then be accessed through the frEndptRtdTestDelay object. To invoke a test, the frEndptAdminStatus is required to be set to test(4). The NoLoop options provide the user the capability to execute the tests without automatically invoking a loopback at the remote endpoint." ::= { frEndptEntry 45 } frEndptRtdTestDelay OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is the calculated round trip delay (measured in milliseconds) of this Frame Relay endpoint. A delay test is invoked through setting the frEndptTestType object to TestDelay." ::= { frEndptEntry 46 } frEndptGroupDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "String describing the group this endpoint is associated with. The format of the group text description is domain.node.grp-number (Example, D2.node1.1)." ::= { frEndptEntry 47 } -- -- This table defines Frame Relay connection end-point statistics with -- information in the following areas: -- -- 1. Received or transmitted frame statistics -- 2. Received or transmitted but discarded frame statistics. -- 3. Frame relay flow and congestion control statistics. -- 4. Received or transmitted frame and bytes over CIR. -- frEndptStatTable OBJECT-TYPE SYNTAX SEQUENCE OF FrEndptStatEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Frame Relay End-Point Statistics table." --DEFAULT test-function test-frendptstattable --DEFAULT next-function next-frendptstattable --DEFAULT get-function get-frendptstattable-%t --DEFAULT view-mask IPX-VIEW --DEFAULT locator FRENDPT-STAT-LOCATOR ::= { switchConnection 6 } frEndptStatEntry OBJECT-TYPE SYNTAX FrEndptStatEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Frame Relay End-point Statistics table." INDEX { frEndptIndex } ::= { frEndptStatTable 1 } FrEndptStatEntry ::= SEQUENCE { frEndptRxBytes Counter, frEndptRxBytesDscds Counter, frEndptRxFrms Counter, frEndptRxFrmsDscds Counter, frEndptRxPkts Counter, frEndptRxPktsDscds Counter, frEndptTxBytes Counter, frEndptTxBytesDscds Counter, frEndptTxFrms Counter, frEndptTxFrmsDscds Counter, frEndptTxPkts Counter, frEndptTxFrmsFecns Counter, frEndptTxFrmsBecns Counter, frEndptSecInServices Counter, frEndptCongestMins Counter, frEndptRxFrmsDes Counter, frEndptRxBytesDes Counter, frEndptTxFrmsDes Counter, frEndptRxFrmsDeDscds Counter, frEndptRxFrmsCirs Counter, frEndptRxBytesCirs Counter, frEndptTxFrmsCirs Counter, frEndptTxBytesCirs Counter } frEndptRxBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Endpoint Statistic, the number of frame bytes received from the local frame relay port." ::= { frEndptStatEntry 1 } frEndptRxBytesDscds OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Endpoint Statistic, the number of frame bytes received from the local frame relay port but discarded before being transmitted onto the Muxbus, due to the age of the frame in the IPX system or lack of buffer space." ::= { frEndptStatEntry 2 } frEndptRxFrms OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Endpoint Statistic, the number of frames received from the local frame relay port." ::= { frEndptStatEntry 3 } frEndptRxFrmsDscds OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Endpoint Statistic, the number of frames received from the local frame relay port but discarded before being transmitted onto the Muxbus, due to the age of the frame in the IPX system or lack of buffer space " ::= { frEndptStatEntry 4 } frEndptRxPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Endpoint Statistic, the number of packets received from the Muxbus by the local port card." ::= { frEndptStatEntry 5 } frEndptRxPktsDscds OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Endpoint Statistic, the number of packets received from the Muxbus by the local port card but discarded before being transmitted." ::= { frEndptStatEntry 6 } frEndptTxBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Endpoint Statistic, the number of frame bytes received from the Muxbus and transmitted out the frame relay port." ::= { frEndptStatEntry 7 } frEndptTxBytesDscds OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Endpoint Statistic, the number of frame bytes received from the Muxbus but discarded before being transmitted out the frame relay port, due to the age of the frame in the IPX system, CRC error, or lack of buffer space." ::= { frEndptStatEntry 8 } frEndptTxFrms OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Endpoint Statistic, the number of frames transmitted out the frame relay port." ::= { frEndptStatEntry 9 } frEndptTxFrmsDscds OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Endpoint Statistic, the number of frames, which are discarded by the local frame relay card before being transmitted out the local port, due to the age of the frame in the IPX system, a CRC error, or lack of buffer space." ::= { frEndptStatEntry 10 } frEndptTxPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Endpoint Statistic, the number of packets tranmitted to the Muxbus by the local port card." ::= { frEndptStatEntry 11 } frEndptTxFrmsFecns OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Endpoint Statistic, the number of frames transmitted out the local frame relay port with FECN bit set." ::= { frEndptStatEntry 12 } frEndptTxFrmsBecns OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Endpoint Statistic, the number of frames transmitted out the local frame relay port with BECN bit set." ::= { frEndptStatEntry 13 } frEndptSecInServices OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Endpoint Statistic, the number of seconds in which a connection is in service. A connection is considered to be in service if its end point is not in alarm, the cards required to support the connection are present and the connection is routed." ::= { frEndptStatEntry 14 } frEndptCongestMins OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Endpoint Statistic, number of minutes in which 50% or more frames are tagged FECN by the FRP." ::= { frEndptStatEntry 15 } frEndptRxFrmsDes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Endpoint Statistic, the number of frames received from the local frame relay port with their DE bit set. DE bits are only counted by model D frame relay firmware or later." ::= { frEndptStatEntry 16 } frEndptRxBytesDes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Endpoint Statistic, the number of frames received from the local frame relay port with their DE bit set. DE bits are only counted by model D frame relay firmware or later." ::= { frEndptStatEntry 17 } frEndptTxFrmsDes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Endpoint Statistic, the number of frames transmitted out the local frame relay port with their DE bit set. DE bits are only counted by model D frame relay firmware or later." ::= { frEndptStatEntry 18 } frEndptRxFrmsDeDscds OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Endpoint Statistic, the number of frame received from the local frame relay port with their DE bit set, which are discarded before being transmitted onto the Muxbus. DE bits are only counted by model D frame relay firmware or later." ::= { frEndptStatEntry 19 } frEndptRxFrmsCirs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Endpoint Rx frames from port in excess of CIR." ::= { frEndptStatEntry 20 } frEndptRxBytesCirs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Endpoint Rx bytes from port in excess of CIR." ::= { frEndptStatEntry 21 } frEndptTxFrmsCirs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Endpoint Tx frames from port in excess of CIR." ::= { frEndptStatEntry 22 } frEndptTxBytesCirs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay Endpoint Tx bytes from port in excess of CIR." ::= { frEndptStatEntry 23 } -- This table describes frame relay bandwith classes available on -- the node. In order to avoid specifying all the bandwidth parameters -- while creating a frame relay connection user can specify a -- frame relay bandwidth class by its number (available as index into -- this table). -- frBwClassTable OBJECT-TYPE SYNTAX SEQUENCE OF FrBwClassEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Frame Relay Bandwidth Class table." --DEFAULT test-function test-frbwclasstable --DEFAULT next-function next-frbwclasstable --DEFAULT get-function get-frbwclasstable-%t --DEFAULT view-mask IPX-VIEW ::= { switchConnection 7 } frBwClassEntry OBJECT-TYPE SYNTAX FrBwClassEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Frame Relay Bandwidth Class table." INDEX { frBwClassIndex } ::= { frBwClassTable 1 } FrBwClassEntry ::= SEQUENCE { frBwClassIndex INTEGER, frBwClassMIR INTEGER, frBwClassCIR INTEGER, frBwClassVcQSize INTEGER, frBwClassBc INTEGER, frBwClassPIR INTEGER, frBwClassBe INTEGER, frBwClassCMAX INTEGER, frBwClassEcnQSize INTEGER, frBwClassQIR INTEGER, frBwClassPercUtil INTEGER, frBwClassOeMIR INTEGER, frBwClassOeCIR INTEGER, frBwClassOeVcQSize INTEGER, frBwClassOeBc INTEGER, frBwClassOePIR INTEGER, frBwClassOeBe INTEGER, frBwClassOeCMAX INTEGER, frBwClassOeEcnQSize INTEGER, frBwClassOeQIR INTEGER, frBwClassOePercUtil INTEGER, frBwClassEnableFST INTEGER, frBwClassDescription DisplayString } frBwClassIndex OBJECT-TYPE SYNTAX INTEGER (1..10) ACCESS read-only STATUS mandatory DESCRIPTION "Index into FrBwClassTable. This index identifies the frame relay bandwidth class." ::= { frBwClassEntry 1 } frBwClassMIR OBJECT-TYPE SYNTAX INTEGER (2400..2048000) ACCESS read-only STATUS mandatory DESCRIPTION "The minimum transmit bandwidth (MIR) parameter (in 100s of bits per second) for this end-point." ::= { frBwClassEntry 2 } frBwClassCIR OBJECT-TYPE SYNTAX INTEGER (2400..2048000) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is equal to the committed information rate (CIR) parameter (in 100s of bits per second) for this end-point." ::= { frBwClassEntry 3 } frBwClassVcQSize OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is the maximum queue depth (in bytes) for this end-point." ::= { frBwClassEntry 4 } frBwClassBc OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is equal to the committed burst size (Bc) parameter (in bytes) for this end-point." ::= { frBwClassEntry 5 } frBwClassPIR OBJECT-TYPE SYNTAX INTEGER (2400..2048000) ACCESS read-only STATUS mandatory DESCRIPTION "The peak transmit bandwidth (PIR) parameter (in 100s of bits per second) for this end-point." ::= { frBwClassEntry 6 } frBwClassBe OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is equal to the excess burst size (Be) parameter (in bytes) for this end-point." ::= { frBwClassEntry 7 } frBwClassCMAX OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "The maximum credits that can be accrued for this end-point." ::= { frBwClassEntry 8 } frBwClassEcnQSize OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The threshold setting used by the explicit congestion notification feature for this end-point's transmit queue. This value is specified in bytes." ::= { frBwClassEntry 9 } frBwClassQIR OBJECT-TYPE SYNTAX INTEGER (2400..2048000) ACCESS read-only STATUS mandatory DESCRIPTION "The transmit quiescent information rate (QIR) parameter (in 100s of bits per second) for this end-point. This value can range between the MIR and PIR values and must be between 2400 and 2048000. This parameter has meaning only if the frEndptEnableFST parameter is set to true." ::= { frBwClassEntry 10 } frBwClassPercUtil OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is equal to the channel percentage utilization setting for this end-point. This is the expected long-term utilization of the channel by this end-point." ::= { frBwClassEntry 11 } frBwClassOeMIR OBJECT-TYPE SYNTAX INTEGER (2400..2048000) ACCESS read-only STATUS mandatory DESCRIPTION "The minimum receive bandwidth (MIR) parameter (in 100s of bits per second) for the other end-point." ::= { frBwClassEntry 12 } frBwClassOeCIR OBJECT-TYPE SYNTAX INTEGER (2400..2048000) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is equal to the committed information rate (CIR) parameter (in 100s of bits per second) for the other end-point." ::= { frBwClassEntry 13 } frBwClassOeVcQSize OBJECT-TYPE SYNTAX INTEGER (1..3072000) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is the maximum queue depth (in bytes) for this end-point." ::= { frBwClassEntry 14 } frBwClassOeBc OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is equal to the committed burst size (Bc) parameter (in bytes) for the end-point." ::= { frBwClassEntry 15 } frBwClassOePIR OBJECT-TYPE SYNTAX INTEGER (2400..2048000) ACCESS read-only STATUS mandatory DESCRIPTION "The peak receive bandwidth (PIR) parameter (in 100s of bits per second) for the other end-point." ::= { frBwClassEntry 16 } frBwClassOeBe OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is equal to the excess burst size (Be) parameter (in bytes) for the other end-point." ::= { frBwClassEntry 17 } frBwClassOeCMAX OBJECT-TYPE SYNTAX INTEGER (1..57600) ACCESS read-only STATUS mandatory DESCRIPTION "The maximum credits that can be accrued for the other end-point." ::= { frBwClassEntry 18 } frBwClassOeEcnQSize OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The threshold setting used by the explicit congestion notification feature for the other end-point's receive queue. This value is specified in bytes." ::= { frBwClassEntry 19 } frBwClassOeQIR OBJECT-TYPE SYNTAX INTEGER (2400..2048000) ACCESS read-only STATUS mandatory DESCRIPTION "The receive quiescent information rate (QIR) parameter (in 100s of bits per second) for the other end-point." ::= { frBwClassEntry 20 } frBwClassOePercUtil OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is equal to the channel percentage utilization setting for the other end-point." ::= { frBwClassEntry 21 } frBwClassEnableFST OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object determines whether or not the ForeSight option is being used for this . If set to false, then ForeSight is not used, and if true then ForeSight will be used." ::= { frBwClassEntry 22 } frBwClassDescription OBJECT-TYPE SYNTAX DisplayString ( SIZE (0..24) ) ACCESS read-only STATUS mandatory DESCRIPTION "This MIB object contains a textual description of this frame relay bandwidth class." ::= { frBwClassEntry 23 } -- -- This is the table describing an ATM connection end-point. -- Each connection (virtual circuit or ) end-point describes the -- particular characteristics of the end-point. Such information -- as local and remote end-point description, class of service, input -- and output bandwidth parameters, and special options are maintained -- in the end-point table. -- This table is only applicable on the BPX switch. -- atmEndptTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmEndptEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The ATM End-Point table. This table is used to model a PVC end-point. This table contains the traffic parameters for ATM end-point." --DEFAULT test-function test-atmendpttable --DEFAULT next-function next-atmendpttable --DEFAULT get-function get-atmendpttable-%t --DEFAULT view-mask BPX-VIEW ::= { switchConnection 8 } atmEndptEntry OBJECT-TYPE SYNTAX AtmEndptEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the ATM End-point table." INDEX { atmEndptIndex } ::= { atmEndptTable 1 } AtmEndptEntry ::= SEQUENCE { atmEndptIndex INTEGER, atmEndptDesc DisplayString, atmOtherEndptIndex INTEGER, atmOtherEndptDesc DisplayString, atmEndptAdminStatus INTEGER, atmEndptOperStatus INTEGER, atmNoRouteFoundFailure INTEGER, atmBumpFailure INTEGER, atmEndPointFailure INTEGER, atmTestFailure INTEGER, atmConnPtr OBJECT IDENTIFIER, atmNextPtr OBJECT IDENTIFIER, atmNextOnPortPtr OBJECT IDENTIFIER, atmEndptConnDesc DisplayString, atmEndptTrkAvoidType INTEGER, atmEndptTrkAvoidZCS INTEGER, atmEndptSubType INTEGER, atmEndptBWClass INTEGER, atmEndptMIR INTEGER, atmEndptCIR INTEGER, atmEndptVcQSize INTEGER, atmEndptPIR INTEGER, atmEndptEfciQSize INTEGER, atmEndptQIR INTEGER, atmEndptPercUtil INTEGER, atmEndptCBS INTEGER, atmEndptIBS INTEGER, atmEndptMFS INTEGER, atmEndptCCDV INTEGER, atmEndptHiCLP INTEGER, atmEndptLoCLP INTEGER, atmEndptOeMIR INTEGER, atmEndptOeCIR INTEGER, atmEndptOeVcQSize INTEGER, atmEndptOePIR INTEGER, atmEndptOeEfciQSize INTEGER, atmEndptOeQIR INTEGER, atmEndptOePercUtil INTEGER, atmEndptOeCBS INTEGER, atmEndptOeIBS INTEGER, atmEndptOeMFS INTEGER, atmEndptOeCCDV INTEGER, atmEndptOeHiCLP INTEGER, atmEndptOeLoCLP INTEGER, atmEndptCLPTagging INTEGER, atmEndptUPC INTEGER, atmEndptEnableFST INTEGER, atmEndptRateUpICA INTEGER, atmEndptRateDnICA INTEGER, atmEndptFastDnICA INTEGER, atmEndptToQIR INTEGER, atmEndptMinAdjustICA INTEGER, atmEndptGroupFlag INTEGER, atmEndptOamStatus INTEGER, atmEndptBCM INTEGER, atmEndptFGCRA INTEGER, atmEndptLocLpbkState INTEGER, atmEndptLpbkStatus INTEGER, atmEndptTestType INTEGER, atmEndptRtdTestDelay INTEGER, atmEndptOeBCM INTEGER, atmEndptOeFGCRA INTEGER, atmEndptGroupDesc DisplayString, atmEndptLocRmtLpbkState INTEGER, atmEndptScrPlc INTEGER, atmEndptOeScrPlc INTEGER, atmEndptPCR0 INTEGER, atmEndptOePCR0 INTEGER, atmEndptCDVT0 INTEGER, atmEndptOeCDVT0 INTEGER, atmEndptOeRateUpICA INTEGER, atmEndptFRTT INTEGER, atmEndptTBE INTEGER, atmEndptVSVD INTEGER, atmEndptPolicing INTEGER, atmEndptPCR INTEGER } atmEndptIndex OBJECT-TYPE SYNTAX INTEGER (0..9999) ACCESS read-only STATUS mandatory DESCRIPTION "Index into table for this end-point. Although only 5000 endpoints may exist on a node, 10000 possible index values exist to support DAX (intra-node) connections." ::= { atmEndptEntry 1 } atmEndptDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "String describing this end-point. Contains information about the domain, nodename, slot, port, vpi, and vci for the end-point. For example, D1.Node1.12.1.100.200, is a valid description. Domain and nodename need not be given but slot, port, VPI and VCI values must exist; 12.1.100.200 is valid. A virtual path connection endpoint of the form 12.1.100.* is also valid. For a basis port the last 4 bits of the VPI must be between 3 and 14." ::= { atmEndptEntry 2 } atmOtherEndptIndex OBJECT-TYPE SYNTAX INTEGER (0..9999) ACCESS read-only STATUS mandatory DESCRIPTION "Index into remote node's atmEndptTable for this end-point. For DAX (intra-node) connections, this index is associated with the local node and will be in the range of 5000 to 9999." ::= { atmEndptEntry 3 } atmOtherEndptDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "String describing the remote PVC end-point. Contains information about the domain, nodename, slot, port, vpi, and vci for the end-point. For example, D2.Node2.10.1.100.200, is a valid description. Nodename, slot, port, VPI and VCI values must exist. A virtual path connection endpoint of the form D2.Node2.10.1.100.* is also valid. For a basis port the last 4 bits of the VPI must be between 3 and 14." ::= { atmEndptEntry 4 } atmEndptAdminStatus OBJECT-TYPE SYNTAX INTEGER { create(1), delete(2), modify(3), test(4), writeOnly(5) } ACCESS read-write STATUS mandatory DESCRIPTION "User requested state for end-point table row. A user can create this VC or delete this VC by setting this object appropriately. If the end-point is to be modified, set this object identifier to be modify." ::= { atmEndptEntry 5 } atmEndptOperStatus OBJECT-TYPE SYNTAX INTEGER { ok(1), okPendingDown(2), down(3), failed(4), inTest(5), okPendingRoute(6), okPendingDelete(7), looped(8), unknown(9) } ACCESS read-only STATUS mandatory DESCRIPTION "Actual state of the end-point. If the state is failed, then look to the objects atmNoRouteFoundFailure, atmBumpFailure, atmEndPointFailure, and atmTestFailure to determine reason for failure." ::= { atmEndptEntry 6 } atmNoRouteFoundFailure OBJECT-TYPE SYNTAX INTEGER { false(1), true(2) } ACCESS read-only STATUS mandatory DESCRIPTION "End-point is failed is because no route to the remote end-point could be found." ::= { atmEndptEntry 7 } atmBumpFailure OBJECT-TYPE SYNTAX INTEGER { false(1), true(2) } ACCESS read-only STATUS mandatory DESCRIPTION "End-point is failed because of insufficient bandwidth to route to the remote end-point. This may have also been caused because a higher priority connection took this end-point's bandwidth. A higher priority connection is one with the lowest class of service (COS)." ::= { atmEndptEntry 8 } atmEndPointFailure OBJECT-TYPE SYNTAX INTEGER { false(1), true(2) } ACCESS read-only STATUS mandatory DESCRIPTION "End-point is failed because of a remote end-point failure. The remote end-point is on a node that resides in another domain making the connection an inter-domain connection." ::= { atmEndptEntry 9 } atmTestFailure OBJECT-TYPE SYNTAX INTEGER { false(1), true(2) } ACCESS read-only STATUS mandatory DESCRIPTION "End-point is failed because of the failure of a connection test." ::= { atmEndptEntry 10 } atmConnPtr OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "Pointer to general connection information. Using this pointer the user can obtain connection status, and routing information. Specifically, this is an object identifier specifying the first column of the appropriate row in the connTable." ::= { atmEndptEntry 11 } atmNextPtr OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "Pointer to next end-point information. This allows logical sets of end-points to be linked up. For example, the end-points associated with a bundle or group. Specifically, this is an object identifier specifying the first column of the appropriate row in the atmEndptTable." ::= { atmEndptEntry 12 } atmNextOnPortPtr OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "Pointer to next end-point information for the port associated with this end-point. For example, using this pointer all atm end-points on a given slot.port can be determined. Specifically, this is an object identifier specifying the first column of the appropriate row in the atmEndptTable." ::= { atmEndptEntry 13 } atmEndptConnDesc OBJECT-TYPE SYNTAX DisplayString ( SIZE (0..20) ) ACCESS read-write STATUS mandatory DESCRIPTION "A string that has been defined for the connection to give a more descriptive name. Connections can be given clear text names in order to make them more human readable." ::= { atmEndptEntry 14 } atmEndptTrkAvoidType OBJECT-TYPE SYNTAX INTEGER { none(1), satellite(2), terrestrial(3) } ACCESS read-write STATUS mandatory DESCRIPTION "User selectable types of trunks to avoid for the transfer of ATM data. Current choices are to avoid satellite links, terrestrial links, or to not avoid any specific type of link. This object is optional during the creation of an endpoint." ::= { atmEndptEntry 15 } atmEndptTrkAvoidZCS OBJECT-TYPE SYNTAX INTEGER { false(1), true(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Flag to force the connection to avoid trunks with zero code suppression (ZCS). This object is optional during the creation of an endpoint." ::= { atmEndptEntry 16 } atmEndptSubType OBJECT-TYPE SYNTAX INTEGER { atf(1), vbr(2), cbr(3), unknown(4), abr(5), atfst(6) } ACCESS read-write STATUS mandatory DESCRIPTION "ATM endpoint subtype object. atf - Interworking conn (without Foresight) vbr - Variable Bit Rate Conn (No ForeSight) cbr - Constant Bit Rate Conn (No ForeSight) abr - Available Bit Rte Conn (With ForeSight) atfst - Interworking Conn (with ForeSight)." ::= { atmEndptEntry 17 } atmEndptBWClass OBJECT-TYPE SYNTAX INTEGER (1..10) ACCESS read-write STATUS mandatory DESCRIPTION "User selectable connection class which defines the operating parameters for the connection. Any or all of these parameters can be overridden by specifying the bandwidth parameters directly. This object is required during the creation of an endpoint." ::= { atmEndptEntry 18 } atmEndptMIR OBJECT-TYPE SYNTAX INTEGER (0..353208) ACCESS read-write STATUS mandatory DESCRIPTION "The minimum transmit bandwidth (MIR) parameter (in cells per second) for this end-point. The maximum value for this object is the port speed of the associated interface. This object does not apply to CBR connections. For VBR and ATF without Foresight connections this object corresponds to the PCR(0+1) parameter defined by ATM standard documents. For ABR and ATF with Foresight connections this object corresponds to the Minimum Cell Rate (MCR)." ::= { atmEndptEntry 19 } atmEndptCIR OBJECT-TYPE SYNTAX INTEGER (7..353208) ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is equal to the committed information rate (CIR) parameter (in cells per second) for this end-point. For CBR connections this object corresponds to the PCR(0+1) parameter defined by ATM standard documents. For VBR, ABR, and ATF connections this object corresponds to the Sustainable Cell Rate (SCR) defined by ATM standard documents. The maximum value for this object is the port speed of the associated interface. For T3 and E3 interfaces only multiples of 10 are used internally. For OC3 interfaces only values in the following set are used internally: 11, 17, 23, 34, 45, 68, 90, 136, 181, 271, 362, 543, 723, 1085, 1447, 2170, 2894, 4340, 5787, 8681, 11574, 17361, 23148, 34722, 46296, 69444, 92593, 138889, 185185, 277778. Values between 277778 and 353208 are all valid for OC3 interfaces. All values in the valid range for a given interface will be accepted, but they will be internally rounded up to the closest higher value valid for that interface." ::= { atmEndptEntry 20 } atmEndptVcQSize OBJECT-TYPE SYNTAX INTEGER (1..64000) ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the maximum queue depth (in cells) for this end-point. This object does not apply to vbr or cbr connections." ::= { atmEndptEntry 21 } atmEndptPIR OBJECT-TYPE SYNTAX INTEGER (7..353208) ACCESS read-write STATUS mandatory DESCRIPTION "The peak transmit bandwidth (PIR) parameter (in cells per second) for this end-point. The maximum value for this object is the port speed of the associated interface. This object applies only to ABR and ATF with Foresight connections and corresponds to the PCR(0+1) parameter defined by ATM standard documents." ::= { atmEndptEntry 22 } atmEndptEfciQSize OBJECT-TYPE SYNTAX INTEGER (1..100) ACCESS read-write STATUS mandatory DESCRIPTION "The threshold setting used by the explicit congestion notification feature for this end-point's transmit queue. This value is a percentage. This object does not apply to vbr or cbr connections." ::= { atmEndptEntry 23 } atmEndptQIR OBJECT-TYPE SYNTAX INTEGER (0..96000) ACCESS read-write STATUS mandatory DESCRIPTION "The transmit quiescent information rate (QIR) parameter (in cells per second) for this end-point. This value can range between the MIR and PIR values and must be between 0 and 96000. This parameter has meaning only for Foresight connections. This object corresponds to the Initial Cell Rate (ICR)." ::= { atmEndptEntry 24 } atmEndptPercUtil OBJECT-TYPE SYNTAX INTEGER (1..100) ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is equal to the channel percentage utilization setting for this end-point. This is the expected long-term utilization of the channel by this end-point." ::= { atmEndptEntry 25 } atmEndptCBS OBJECT-TYPE SYNTAX INTEGER (1..24000) ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is equal to the Compliant Burst Size in cells for this end-point. The maximum value for this object on OC3 end points is 1000. This object corresponds to the Maximum Burst Size (MBS) defined by ATM standard documents. This object can be set if atmEndptUPC is enabled." ::= { atmEndptEntry 26 } atmEndptIBS OBJECT-TYPE SYNTAX INTEGER (0..24000) ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is equal to the Initial Burst Size in cells for this end-point. The maximum value for this object on OC3 end points is 1000. This object does not apply to vbr or cbr connections." ::= { atmEndptEntry 27 } atmEndptMFS OBJECT-TYPE SYNTAX INTEGER (1..200) ACCESS read-write STATUS mandatory DESCRIPTION "This object is not used by the new UPC algorithm, and its value is meaningless. Any attempt to write to this object will fail." ::= { atmEndptEntry 28 } atmEndptCCDV OBJECT-TYPE SYNTAX INTEGER (0..250000) ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is equal to the Compliant Cell Delay Variation for this end-point. It corresponds to the CDVT(0+1) parameter defined by the ATM standard documents. This object can be set if atmEndptUPC is enabled. The maximum value for this object on OC3 end points is 10000." ::= { atmEndptEntry 29 } atmEndptHiCLP OBJECT-TYPE SYNTAX INTEGER (1..100) ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is equal to the CLP (Cell Loss Priority) tagging activation threshold for this end-point. This object only applies to Foresight connections." ::= { atmEndptEntry 30 } atmEndptLoCLP OBJECT-TYPE SYNTAX INTEGER (1..100) ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is equal to the CLP (Cell Loss Priority) tagging deactivation threshold for this end-point. This object only applies to Foresight connections." ::= { atmEndptEntry 31 } atmEndptOeMIR OBJECT-TYPE SYNTAX INTEGER (0..353208) ACCESS read-write STATUS mandatory DESCRIPTION "The minimum receive bandwidth (MIR) parameter (in cells per second) for the other end-point. The maximum value for this object is the port speed of the associated interface. This object does not apply to CBR connections. For VBR and ATF without Foresight connections this object corresponds to the PCR(0+1) parameter defined by ATM standard documents. For ABR and ATF with Foresight connections this object corresponds to the Minimum Cell Rate (MCR)." ::= { atmEndptEntry 32 } atmEndptOeCIR OBJECT-TYPE SYNTAX INTEGER (7..353208) ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is equal to the committed information rate (CIR) parameter (in cells per second) for the other end-point. For CBR connections this object corresponds to the PCR(0+1) parameter defined by ATM standard documents. For VBR, ABR, and ATF connections this object corresponds to the Sustainable Cell Rate (SCR) defined by ATM standard documents. The maximum value for this object is the port speed of the associated interface. For T3 and E3 interfaces only multiples of 10 are used internally. For OC3 interfaces only values in the following set are used internally: 11, 17, 23, 34, 45, 68, 90, 136, 181, 271, 362, 543, 723, 1085, 1447, 2170, 2894, 4340, 5787, 8681, 11574, 17361, 23148, 34722, 46296, 69444, 92593, 138889, 185185, 277778. Values between 277778 and 353208 are all valid for OC3 interfaces. All values in the valid range for a given interface will be accepted, but they will be internally rounded up to the closest higher value valid for that interface." ::= { atmEndptEntry 33 } atmEndptOeVcQSize OBJECT-TYPE SYNTAX INTEGER (1..64000) ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the maximum queue depth (in cells) for the other end-point. This object does not apply to vbr or cbr connections." ::= { atmEndptEntry 34 } atmEndptOePIR OBJECT-TYPE SYNTAX INTEGER (7..353208) ACCESS read-write STATUS mandatory DESCRIPTION "The peak receive bandwidth (PIR) parameter (in cells per second) for the other end-point. The maximum value for this object is the port speed of the associated interface. This object applies only to ABR and ATF with Foresight connections and corresponds to the PCR(0+1) parameter defined by ATM standard documents." ::= { atmEndptEntry 35 } atmEndptOeEfciQSize OBJECT-TYPE SYNTAX INTEGER (1..100) ACCESS read-write STATUS mandatory DESCRIPTION "The threshold setting used by the explicit congestion notification feature for the other end-point's transmit queue. This object does not apply to vbr or cbr connections." ::= { atmEndptEntry 36 } atmEndptOeQIR OBJECT-TYPE SYNTAX INTEGER (0..96000) ACCESS read-write STATUS mandatory DESCRIPTION "The transmit quiescent information rate (QIR) parameter (in cells bits per second) for the other end-point. This value can range between the MIR and PIR values and must be between 0 and 96000. This parameter has meaning only for Foresight connections. This object corresponds to the Initial Cell Rate (ICR)." ::= { atmEndptEntry 37 } atmEndptOePercUtil OBJECT-TYPE SYNTAX INTEGER (1..100) ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is equal to the channel percentage utilization setting for the other end-point. This is the expected long-term utilization of the channel by the other end-point." ::= { atmEndptEntry 38 } atmEndptOeCBS OBJECT-TYPE SYNTAX INTEGER (1..24000) ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is equal to the Compliant Burst Size in cells for the other end-point. The maximum value for this object on OC3 end points is 1000. This object corresponds to the Maximum Burst Size (MBS) defined by ATM standard documents. This object can be set if atmEndptUPC is enabled." ::= { atmEndptEntry 39 } atmEndptOeIBS OBJECT-TYPE SYNTAX INTEGER (0..24000) ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is equal to the Initial Burst Size in cells for the other end-point. The maximum value for this object on OC3 end points is 1000. This object does not apply to vbr or cbr connections." ::= { atmEndptEntry 40 } atmEndptOeMFS OBJECT-TYPE SYNTAX INTEGER (1..200) ACCESS read-write STATUS mandatory DESCRIPTION "This object is not used by the new UPC algorithm, and its value is meaningless. Any attempt to write to this object will fail." ::= { atmEndptEntry 41 } atmEndptOeCCDV OBJECT-TYPE SYNTAX INTEGER (0..250000) ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is equal to the Compliant Cell Delay Variation for this end-point. It corresponds to the CDVT(0+1) parameter defined by the ATM standard documents. This object can be set if atmEndptUPC is enabled. The maximum value for this object on OC3 end points is 10000." ::= { atmEndptEntry 42 } atmEndptOeHiCLP OBJECT-TYPE SYNTAX INTEGER (1..100) ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is equal to the CLP (Cell Loss Priority) tagging activation threshold for the other end-point. This object only applies to Foresight connections." ::= { atmEndptEntry 43 } atmEndptOeLoCLP OBJECT-TYPE SYNTAX INTEGER (1..100) ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is equal to the CLP (Cell Loss Priority) tagging deactivation threshold for the other end-point. This object only applies to Foresight connections." ::= { atmEndptEntry 44 } atmEndptCLPTagging OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object enables the CLP (Cell Loss Priority) tagging for handling non-compliant cells. When enabled the CLP bit is set on non- compliant cells. When disabled non-compliant cells are discarded. This object can be set if atmEndptUPC is enabled." ::= { atmEndptEntry 45 } atmEndptUPC OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object enables the UPC algorithm." ::= { atmEndptEntry 46 } atmEndptEnableFST OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object determines whether or not the ForeSight option is being used for this . If set to false, then ForeSight is not used, and if true then ForeSight will be used. Foresight option is not supported on OC3 interfaces." ::= { atmEndptEntry 47 } atmEndptRateUpICA OBJECT-TYPE SYNTAX INTEGER (10..96000) ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is equal to the ForeSight Rate Up value in cells per second per adjust for this end point." ::= { atmEndptEntry 48 } atmEndptRateDnICA OBJECT-TYPE SYNTAX INTEGER (1..100) ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is equal to the ForeSight Rate Down value expressed as percentage of MCR." ::= { atmEndptEntry 49 } atmEndptFastDnICA OBJECT-TYPE SYNTAX INTEGER (1..100) ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is equal to the ForeSight Fast Down value expressed as percentage of MCR." ::= { atmEndptEntry 50 } atmEndptToQIR OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is equal to the QIR timeout value. This object corresponds to the Initial Cell Rate (ICR) timeout." ::= { atmEndptEntry 51 } atmEndptMinAdjustICA OBJECT-TYPE SYNTAX INTEGER (20..250) ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is equal to the ForeSight minimum adjustment period." ::= { atmEndptEntry 52 } atmEndptGroupFlag OBJECT-TYPE SYNTAX INTEGER { false(1), true(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Specifies whether this is a grouped connection. Note that MIB object connGroupFlag provides grouping information about all the connections using that connTable entry whereas this object provides same information for this end point." ::= { atmEndptEntry 53 } atmEndptOamStatus OBJECT-TYPE SYNTAX INTEGER { unknown(1), clear(2), aisDetected(3), ferfDetected(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The end to end OAM state." ::= { atmEndptEntry 54 } atmEndptBCM OBJECT-TYPE SYNTAX INTEGER { enable (1), disable (2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object enables the generation of RM cells when congestion is detected in this connection." ::= { atmEndptEntry 55 } atmEndptFGCRA OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object enables FGCRA. FGCRA (Frame-based Generic Rate Control Algorithm) is applicable with AAL-5 traffic only. This object can be set if atmEndptUPC is enabled." ::= { atmEndptEntry 56 } atmEndptLocLpbkState OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the Local Loopback State the user would like to set for the endpoint." ::= { atmEndptEntry 57 } atmEndptLpbkStatus OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the current Loopback State of the endpoint. The value returned from this object is a bitmap of the current loopback states which the endpoint has configured. There currently are 16 loopback states an endpoint may have configured. The bitmap is defined as follows from LSB to MSB: Remote nodes remote muxbus loopback Remote nodes tstcon loopback Local nodes remoet muxbus loopback Local nodes tstcon loopback Local nodes local muxbus loopback Local nodes port loopback Local nodes port test loopback Remote nodes local muxbus loopback Remote nodes port loopback Remote nodes port test looback Local DDS network requested CSU loopback Remote DDS network requested CSU loopback Local DDS network requested DSU loopback Remote DDS network requested DSU loopback Local DDS external loopback Remote DDS external loopback " ::= { atmEndptEntry 58 } atmEndptTestType OBJECT-TYPE SYNTAX INTEGER { testDelay(1), writeOnly(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the type of test the user would like to conduct on this endpoint. Only testDelay is currently defined. TestDelay calculates the delay incurred on the connection. The result of the TestDelay may then be accessed through the atmEndptRtdTestDelay object. This is a non-disruptive test." ::= { atmEndptEntry 59 } atmEndptRtdTestDelay OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is the calculated round trip delay (measured in milliseconds) for an OAM cell that is sent across the network to the remote node where it is looped back and returned to this node. A delay test is invoked through setting the the atmEndptTestType object to TestDelay." ::= { atmEndptEntry 60 } atmEndptOeBCM OBJECT-TYPE SYNTAX INTEGER { enable (1), disable (2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object enables the generation of RM cells when congestion is detected in this connection. This is the other endpoint view." ::= { atmEndptEntry 61 } atmEndptOeFGCRA OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object enables FGCRA. FGCRA (Frame-based Generic Rate Control Algorithm) is applicable with AAL-5 traffic only. This object can be set if atmEndptUPC is enabled. This is the other endpoint view." ::= { atmEndptEntry 62 } atmEndptGroupDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "String describing the group this endpoint is associated with. The format of the group text description is domain.node.grp-number (Example, D2.node1.1)." ::= { atmEndptEntry 63 } atmEndptLocRmtLpbkState OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the Local-Remote Loopback State the user would like to set for the endpoint." ::= { atmEndptEntry 64 } atmEndptScrPlc OBJECT-TYPE SYNTAX INTEGER { clp0(1), clp0and1(2), off(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the traffic policing for this end point This object can be set only if atmEndptUPC is enabled." ::= { atmEndptEntry 65 } atmEndptOeScrPlc OBJECT-TYPE SYNTAX INTEGER { clp0(1), clp0and1(2), off(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the traffic policing for the other end point. This object can be set only if atmEndptUPC is enabled." ::= { atmEndptEntry 66 } atmEndptPCR0 OBJECT-TYPE SYNTAX INTEGER (7..353208) ACCESS read-write STATUS mandatory DESCRIPTION "The peak cell rate (in cells per second) for the second bucket for this end point. This object corresponds to the parameter PCR(0) in standard ATM documents and applies only to CBR connections. This object can be set only if atmEndptUPC is enabled. PCR(0) must be less or equal than PCR(0+1)." ::= { atmEndptEntry 67 } atmEndptOePCR0 OBJECT-TYPE SYNTAX INTEGER (7..353208) ACCESS read-write STATUS mandatory DESCRIPTION "The peak cell rate (in cells per second) for the second bucket for the other end point. This object corresponds to the parameter PCR(0) in standard ATM documents and applies only to CBR connections. This object can be set only if atmEndptUPC is enabled. PCR(0) must be less or equal than PCR(0+1)." ::= { atmEndptEntry 68 } atmEndptCDVT0 OBJECT-TYPE SYNTAX INTEGER (1..250000) ACCESS read-write STATUS mandatory DESCRIPTION "The cell delay variation tolerance for the second bucket for this end point. This object corresponds to the parameter CDVT(0) in standard ATM documents, and applies only to CBR connections. This object can be set only if atmEndptUPC is enabled." ::= { atmEndptEntry 69 } atmEndptOeCDVT0 OBJECT-TYPE SYNTAX INTEGER (1..250000) ACCESS read-write STATUS mandatory DESCRIPTION "The cell delay variation tolerance for the second bucket for the other end point. This object corresponds to the parameter CDVT(0) in standard ATM documents, and applies only to CBR connections. This object can be set only if atmEndptUPC is enabled." ::= { atmEndptEntry 70 } atmEndptOeRateUpICA OBJECT-TYPE SYNTAX INTEGER (10..96000) ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is equal to the ForeSight Rate Up value in cells per second per adjust for the other end point." ::= { atmEndptEntry 71 } -- The remaining entries come from the 9.1 Mib, we include them here so we can -- have atmEndptPCR in our pcm file. atmEndptFRTT OBJECT-TYPE SYNTAX INTEGER (0..16700) ACCESS read-write STATUS mandatory DESCRIPTION "The Fixed Round-Trip Time (FRTT) is the sum of the fixed and propagation delays from the source to a destination and back. . Units: milliseconds. . Applicable connection types: standard ABR only . Default: 0 . Dependency: VSVD = enable(1) " ::= { atmEndptEntry 72 } atmEndptTBE OBJECT-TYPE SYNTAX INTEGER (0..1048320) ACCESS read-write STATUS mandatory DESCRIPTION "Transient Buffer Exposure (TBE) is the negotiated number of cells that the network would like to limit the source to sending during startup periods, before the first RM-cell returns. . Units: cells . Applicable connection types: standard ABR only . Default: 1048320 . Dependency: VSVD = enable(1) " ::= { atmEndptEntry 73 } atmEndptVSVD OBJECT-TYPE SYNTAX INTEGER { enable (1), disable (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Virtual Source/Virtual Destination (VS/VD) is used to divide an ABR connection into two or more separately controlled ABR segment. This flag indicates whether the ATM end points (both ends) will serve as VS/VD or not. . Applicable connection types: . standard ABR . ABRFST: Cannot be set, but always enable(1). . ATFST : Cannot be set, but always enable(1). . Dependency: . The object CANNOT be MODIFIED after the first set! All Subsequent sets will be rejected! The object can be set when only add ABRSTD connection. ============================================ ABRSTD VSVD option ABRSTD ABRFST ATFST ============================================= available Both (Yes) (Yes) unavalable No (Yes) (Yes) Note: . Yes = Has to be set to enable(1) No = Has to be set to disable(2) Both = can be set to either enable(1) or disable(2) (Yes) = Always enabled and cannot be set. (No) = Always disabled and cannot be set. . Default: disable(2) " ::= { atmEndptEntry 74 } atmEndptPolicing OBJECT-TYPE SYNTAX INTEGER { vbr1 (1), vbr2 (2), vbr3 (3), pcrplc(4), none (5) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the traffic policing for this end point. --------------- ---------- ---------- Policing Type 1st Bucket 2nd Bucket --------------- ---------- ---------- vbr.1 CLP(0+1) CLP(0+1) vbr.2 CLP(0+1) CLP(0) vbr.3 CLP(0+1) CLP(0) with CLP Tagging pcrplc CLP(0+1) none none none none . Applicable connection types: . CBR (only pcrplc(4) or none(5)), VBR, ATFR, . standard ABR, ABR FST, ATFST: VSVD = enable(1) . Default: vbr3(3) . Dependency: Not allowed for standard ABR without VSVD. In this case, it is set to pcrplc(4). " ::= { atmEndptEntry 75 } atmEndptPCR OBJECT-TYPE SYNTAX INTEGER (50..1412832) ACCESS read-write STATUS mandatory DESCRIPTION "PCR(0+1), Peak Cell Rate, specifies an upper bound on rate at which traffic can be submitted on an ATM connection. This object applies to the First Leaky Bucket for leaving cells with Cell Loss Priority of 0 or 1. . Units: cells per second. . Applicable connection types: UBR, CBR, VBR, ATFR, standard ABR, ABR FST, ATFST . Default: 50 or MCR . Ranges: T3 : MCR-96000 E3 : MCR-80000 OC3 : MCR-353208 OC12: MCR-1412832 " ::= { atmEndptEntry 76 } -- This table describes ATM bandwith classes available on -- the switch. In order to avoid specifying all the bandwidth parameters -- while creating an ATM connection, the user can specify an -- ATM bandwidth class by number (available as index into -- this table). -- This table is only applicable on the BPX switch. -- atmBwClassTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmBwClassEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The ATM Bandwidth Class table." --DEFAULT test-function test-atmbwclasstable --DEFAULT next-function next-atmbwclasstable --DEFAULT get-function get-atmbwclasstable-%t --DEFAULT view-mask BPX-VIEW ::= { switchConnection 9 } atmBwClassEntry OBJECT-TYPE SYNTAX AtmBwClassEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the ATM Bandwidth Class table." INDEX { atmBwClassIndex } ::= { atmBwClassTable 1 } AtmBwClassEntry ::= SEQUENCE { atmBwClassIndex INTEGER, atmBwClassMIR INTEGER, atmBwClassCIR INTEGER, atmBwClassVcQSize INTEGER, atmBwClassPIR INTEGER, atmBwClassEfciQSize INTEGER, atmBwClassQIR INTEGER, atmBwClassPercUtil INTEGER, atmBwClassCBS INTEGER, atmBwClassIBS INTEGER, atmBwClassMFS INTEGER, atmBwClassCCDV INTEGER, atmBwClassHiCLP INTEGER, atmBwClassLoCLP INTEGER, atmBwClassOeMIR INTEGER, atmBwClassOeCIR INTEGER, atmBwClassOeVcQSize INTEGER, atmBwClassOePIR INTEGER, atmBwClassOeEfciQSize INTEGER, atmBwClassOeQIR INTEGER, atmBwClassOePercUtil INTEGER, atmBwClassOeCBS INTEGER, atmBwClassOeIBS INTEGER, atmBwClassOeMFS INTEGER, atmBwClassOeCCDV INTEGER, atmBwClassOeHiCLP INTEGER, atmBwClassOeLoCLP INTEGER, atmBwClassCLPTagging INTEGER, atmBwClassUPC INTEGER, atmBwClassEnableFST INTEGER, atmBwClassRateUpICA INTEGER, atmBwClassRateDnICA INTEGER, atmBwClassFastDnICA INTEGER, atmBwClassToQIR INTEGER, atmBwClassMinAdjustICA INTEGER, atmBwClassDescription DisplayString, atmBwClassBCM INTEGER, atmBwClassOeFGCRA INTEGER, atmBwClassOeBCM INTEGER, atmBwClassFGCRA INTEGER, atmBwClassConType INTEGER, atmBwClassScrPlc INTEGER, atmBwClassOeScrPlc INTEGER, atmBwClassPCR0 INTEGER, atmBwClassOePCR0 INTEGER, atmBwClassCDVT0 INTEGER, atmBwClassOeCDVT0 INTEGER, atmBwClassOeRateUpICA INTEGER } atmBwClassIndex OBJECT-TYPE SYNTAX INTEGER (1..10) ACCESS read-only STATUS mandatory DESCRIPTION "Index into atmBwClassTable. This index identifies the ATM bandwidth class." ::= { atmBwClassEntry 1 } atmBwClassMIR OBJECT-TYPE SYNTAX INTEGER (0..353208) ACCESS read-only STATUS mandatory DESCRIPTION "The minimum transmit bandwidth (MIR) parameter (in cells per second) for this end-point. For VBR and ATF without Foresight connections this object corresponds to the PCR(0+1) parameter defined by ATM standard documents. For ABR and ATF with Foresight connections this object corresponds to the Minimum Cell Rate (MCR)." ::= { atmBwClassEntry 2 } atmBwClassCIR OBJECT-TYPE SYNTAX INTEGER (7..353208) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is equal to the committed information rate (CIR) parameter (in cells per second) for this end-point. For CBR connections this object corresponds to the PCR(0+1) parameter defined by ATM standard documents. For VBR, ABR, and ATF connections this object corresponds to the Sustainable Cell Rate (SCR) defined by ATM standard documents." ::= { atmBwClassEntry 3 } atmBwClassVcQSize OBJECT-TYPE SYNTAX INTEGER (1..64000) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is the maximum queue depth (in cells) for this end-point." ::= { atmBwClassEntry 4 } atmBwClassPIR OBJECT-TYPE SYNTAX INTEGER (7..96000) ACCESS read-only STATUS mandatory DESCRIPTION "The peak transmit bandwidth (PIR) parameter (in cells per second) for this end-point. This object applies only to ABR and ATF with Foresight connections and corresponds to the PCR(0+1) parameter defined by ATM standard documents." ::= { atmBwClassEntry 5 } atmBwClassEfciQSize OBJECT-TYPE SYNTAX INTEGER (1..100) ACCESS read-only STATUS mandatory DESCRIPTION "The threshold setting used by the explicit congestion notification feature for this end-point's transmit queue. This value is a percentage." ::= { atmBwClassEntry 6 } atmBwClassQIR OBJECT-TYPE SYNTAX INTEGER (0..96000) ACCESS read-only STATUS mandatory DESCRIPTION "The transmit quiescent information rate (QIR) parameter (in cells per second) for this end-point. This value can range between the MIR and PIR values and must be between 0 and 96000. This parameter has meaning only for Foresight connections. This object corresponds to the Initial Cell Rate (ICR)." ::= { atmBwClassEntry 7 } atmBwClassPercUtil OBJECT-TYPE SYNTAX INTEGER (1..100) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is equal to the channel percentage utilization setting for this end-point. This is the expected long-term utilization of the channel by this end-point." ::= { atmBwClassEntry 8 } atmBwClassCBS OBJECT-TYPE SYNTAX INTEGER (1..24000) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is equal to the Compliant Burst Size in cells for this end-point. This object corresponds to the Maximum Burst Size (MBS) defined by ATM standard documents." ::= { atmBwClassEntry 9 } atmBwClassIBS OBJECT-TYPE SYNTAX INTEGER (0..24000) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is equal to the Initial Burst Size in cells for this end-point." ::= { atmBwClassEntry 10 } atmBwClassMFS OBJECT-TYPE SYNTAX INTEGER (1..200) ACCESS read-only STATUS mandatory DESCRIPTION "This object is not used by the new UPC algorithm, and its value is meaningless." ::= { atmBwClassEntry 11 } atmBwClassCCDV OBJECT-TYPE SYNTAX INTEGER (0..250000) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is equal to the Compliant Cell Delay Variation for this end-point. It corresponds to the CDVT(0+1) parameter defined by the ATM standard documents." ::= { atmBwClassEntry 12 } atmBwClassHiCLP OBJECT-TYPE SYNTAX INTEGER (1..100) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is equal to the CLP (Cell Loss Priority) tagging activation threshold for this end-point." ::= { atmBwClassEntry 13 } atmBwClassLoCLP OBJECT-TYPE SYNTAX INTEGER (1..100) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is equal to the CLP (Cell Loss Priority) tagging deactivation threshold for this end-point." ::= { atmBwClassEntry 14 } atmBwClassOeMIR OBJECT-TYPE SYNTAX INTEGER (0..353208) ACCESS read-only STATUS mandatory DESCRIPTION "The minimum receive bandwidth (MIR) parameter (in cells per second) for the other end-point. For VBR and ATF without Foresight connections this object corresponds to the PCR(0+1) parameter defined by ATM standard documents. For ABR and ATF with Foresight connections this object corresponds to the Minimum Cell Rate (MCR)." ::= { atmBwClassEntry 15 } atmBwClassOeCIR OBJECT-TYPE SYNTAX INTEGER (7..353208) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is equal to the committed information rate (CIR) parameter (in cells per second) for the other end-point. For CBR connections this object corresponds to the PCR(0+1) parameter defined by ATM standard documents. For VBR, ABR, and ATF connections this object corresponds to the Sustainable Cell Rate (SCR) defined by ATM standard documents." ::= { atmBwClassEntry 16 } atmBwClassOeVcQSize OBJECT-TYPE SYNTAX INTEGER (1..64000) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is the maximum queue depth (in cells) for the other end-point." ::= { atmBwClassEntry 17 } atmBwClassOePIR OBJECT-TYPE SYNTAX INTEGER (7..96000) ACCESS read-only STATUS mandatory DESCRIPTION "The peak receive bandwidth (PIR) parameter (in cells per second) for the other end-point. This object applies only to ABR and ATF with Foresight connections and corresponds to the PCR(0+1) parameter defined by ATM standard documents." ::= { atmBwClassEntry 18 } atmBwClassOeEfciQSize OBJECT-TYPE SYNTAX INTEGER (1..100) ACCESS read-only STATUS mandatory DESCRIPTION "The threshold setting used by the explicit congestion notification feature for the other end-point's transmit queue." ::= { atmBwClassEntry 19 } atmBwClassOeQIR OBJECT-TYPE SYNTAX INTEGER (0..96000) ACCESS read-only STATUS mandatory DESCRIPTION "The transmit quiescent information rate (QIR) parameter (in cells bits per second) for the other end-point. This value can range between the MIR and PIR values and must be between 0 and 96000. This parameter has meaning only for Foresight connections. This object corresponds to the Initial Cell Rate (ICR)." ::= { atmBwClassEntry 20 } atmBwClassOePercUtil OBJECT-TYPE SYNTAX INTEGER (1..100) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is equal to the channel percentage utilization setting for the other end-point. This is the expected long-term utilization of the channel by the other end-point." ::= { atmBwClassEntry 21 } atmBwClassOeCBS OBJECT-TYPE SYNTAX INTEGER (1..24000) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is equal to the Compliant Burst Size in cells for the other end-point. This object corresponds to the Maximum Burst Size (MBS) defined by ATM standard documents." ::= { atmBwClassEntry 22 } atmBwClassOeIBS OBJECT-TYPE SYNTAX INTEGER (0..24000) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is equal to the Initial Burst Size in cells for the other end-point." ::= { atmBwClassEntry 23 } atmBwClassOeMFS OBJECT-TYPE SYNTAX INTEGER (1..200) ACCESS read-only STATUS mandatory DESCRIPTION "This object is not used by the new UPC algorithm, and its value is meaningless." ::= { atmBwClassEntry 24 } atmBwClassOeCCDV OBJECT-TYPE SYNTAX INTEGER (0..250000) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is equal to the Compliant Cell Delay Variation for the other end-point. It corresponds to the CDVT(0+1) parameter defined by the ATM standard documents." ::= { atmBwClassEntry 25 } atmBwClassOeHiCLP OBJECT-TYPE SYNTAX INTEGER (1..100) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is equal to the CLP (Cell Loss Priority) tagging activation threshold for the other end-point." ::= { atmBwClassEntry 26 } atmBwClassOeLoCLP OBJECT-TYPE SYNTAX INTEGER (1..100) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is equal to the CLP (Cell Loss Priority) tagging deactivation threshold for the other end-point." ::= { atmBwClassEntry 27 } atmBwClassCLPTagging OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object enables the CLP (Cell Loss Priority) tagging for handling non-compliant cells. When enabled the CLP bit is set on non- compliant cells. When disabled non-compliant cells are discarded." ::= { atmBwClassEntry 28 } atmBwClassUPC OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object enables the UPC algorithm." ::= { atmBwClassEntry 29 } atmBwClassEnableFST OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object determines whether or not the ForeSight option is being used for this . If set to false, then ForeSight is not used, and if true then ForeSight will be used." ::= { atmBwClassEntry 30 } atmBwClassRateUpICA OBJECT-TYPE SYNTAX INTEGER (10..96000) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is equal to the ForeSight Rate Up value in cells per second per adjust for this end point." ::= { atmBwClassEntry 31 } atmBwClassRateDnICA OBJECT-TYPE SYNTAX INTEGER (1..100) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is equal to the ForeSight Rate Down value expressed as percentage of MCR." ::= { atmBwClassEntry 32 } atmBwClassFastDnICA OBJECT-TYPE SYNTAX INTEGER (1..100) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is equal to the ForeSight Fast Down value expressed as percentage of MCR." ::= { atmBwClassEntry 33 } atmBwClassToQIR OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is equal to the QIR timeout value. This object corresponds to the Initial Cell Rate (ICR) timeout." ::= { atmBwClassEntry 34 } atmBwClassMinAdjustICA OBJECT-TYPE SYNTAX INTEGER (20..250) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is equal to the ForeSight minimum adjustment period." ::= { atmBwClassEntry 35 } atmBwClassDescription OBJECT-TYPE SYNTAX DisplayString ( SIZE (0..24) ) ACCESS read-only STATUS mandatory DESCRIPTION "This MIB object contains a textual description of this frame relay bandwidth class." ::= { atmBwClassEntry 36 } atmBwClassBCM OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object enables the generation of RM cells when congestion is detected in the connection." ::= { atmBwClassEntry 37 } atmBwClassFGCRA OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object enables FGCRA. FGCRA (Frame-based Generic Rate Control Algorithm) is applicable with AAL-5 traffic only." ::= { atmBwClassEntry 38 } atmBwClassOeBCM OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object enables the generation of RM cells when congestion is detected in the connection. This is the other endpoint view." ::= { atmBwClassEntry 39 } atmBwClassOeFGCRA OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object enables FGCRA. FGCRA (Frame-based Generic Rate Control Algorithm) is applicable with AAL-5 traffic only. This is the other endpoint view." ::= { atmBwClassEntry 40 } atmBwClassConType OBJECT-TYPE SYNTAX INTEGER { atf(1), vbr(2), cbr(3), unknown(4), abr(5) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object defines the connection type associated with this class." ::= { atmBwClassEntry 41 } atmBwClassScrPlc OBJECT-TYPE SYNTAX INTEGER { clp0(1), clp0and1(2), off(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the traffic policing for this end point." ::= { atmBwClassEntry 42 } atmBwClassOeScrPlc OBJECT-TYPE SYNTAX INTEGER { clp0(1), clp0and1(2), off(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the traffic policing for the other end point." ::= { atmBwClassEntry 43 } atmBwClassPCR0 OBJECT-TYPE SYNTAX INTEGER (7..353208) ACCESS read-only STATUS mandatory DESCRIPTION "The peak cell rate (in cells per second) for the second bucket for this end point. This object corresponds to the parameter PCR(0) in standard ATM documents." ::= { atmBwClassEntry 44 } atmBwClassOePCR0 OBJECT-TYPE SYNTAX INTEGER (7..353208) ACCESS read-only STATUS mandatory DESCRIPTION "The peak cell rate (in cells per second) for the second bucket for the other end point. This object corresponds to the parameter PCR(0) in standard ATM documents." ::= { atmBwClassEntry 45 } atmBwClassCDVT0 OBJECT-TYPE SYNTAX INTEGER (1..250000) ACCESS read-only STATUS mandatory DESCRIPTION "The cell delay variation tolerance for the second bucket for this end point. This object corresponds to the parameter CDVT(0) in standard ATM documents." ::= { atmBwClassEntry 46 } atmBwClassOeCDVT0 OBJECT-TYPE SYNTAX INTEGER (1..250000) ACCESS read-only STATUS mandatory DESCRIPTION "The cell delay variation tolerance for the second bucket for the other end point. This object corresponds to the parameter CDVT(0) in standard ATM documents." ::= { atmBwClassEntry 47 } atmBwClassOeRateUpICA OBJECT-TYPE SYNTAX INTEGER (10..96000) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is equal to the ForeSight Rate Up value in cells per second per adjust for the other end point." ::= { atmBwClassEntry 48 } -- This table describes a mapping between Frame Relay endpoints -- described by slot.port.dlci and corresponding object identifier -- pointers into connTable and the service specific endptTable. -- This table allows the user to determine the table indeces associated -- with the connection defined by the physical attributes of slot, port, -- and dlci. -- frEndptMapTable OBJECT-TYPE SYNTAX SEQUENCE OF FrEndptMapEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Frame Relay Endpoint-Connection Mapping table." --DEFAULT test-function test-frendptmaptable --DEFAULT next-function next-frendptmaptable --DEFAULT get-function get-frendptmaptable-%t --DEFAULT view-mask IPX-VIEW ::= { switchConnection 10 } frEndptMapEntry OBJECT-TYPE SYNTAX FrEndptMapEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Frame Relay Endpoint Connection Mapping table." INDEX { frEndptMapSlot, frEndptMapPort, frEndptMapDlci } ::= { frEndptMapTable 1 } FrEndptMapEntry ::= SEQUENCE { frEndptMapSlot INTEGER, frEndptMapPort INTEGER, frEndptMapDlci INTEGER, frEndptMapEndptPtr OBJECT IDENTIFIER, frEndptMapConnPtr OBJECT IDENTIFIER } frEndptMapSlot OBJECT-TYPE SYNTAX INTEGER (1..32) ACCESS read-only STATUS mandatory DESCRIPTION "This MIB object contains the slot number associated with the requested connection endpoint." ::= { frEndptMapEntry 1 } frEndptMapPort OBJECT-TYPE SYNTAX INTEGER (1..32) ACCESS read-only STATUS mandatory DESCRIPTION "This MIB object contains the port number associated with the requested connection endpoint." ::= { frEndptMapEntry 2 } frEndptMapDlci OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This MIB object contains the Frame Relay DLCI associated with the requested connection endpoint." ::= { frEndptMapEntry 3 } frEndptMapEndptPtr OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "This MIB object contains a pointer to first column of row in the service specific EndptTable which corresponds to the slot, port, and dlci specified in the columns above." ::= { frEndptMapEntry 4 } frEndptMapConnPtr OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "This MIB object contains a pointer to first column of row in connTable which corresponds to the slot, port, and dlci specified in the columns above." ::= { frEndptMapEntry 5 } -- This table describes a mapping between ATM endpoints -- described by slot.port.vpi.vci and corresponding object identifier -- pointers into connTable and the service specific endptTable. -- This table allows the user to determine the table indeces associated -- with the connection defined by the physical attributes of slot, port, -- vpi, and vci. -- atmEndptMapTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmEndptMapEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The ATM Endpoint-Connection Mapping table." --DEFAULT test-function test-atmendptmaptable --DEFAULT next-function next-atmendptmaptable --DEFAULT get-function get-atmendptmaptable-%t ::= { switchConnection 11 } atmEndptMapEntry OBJECT-TYPE SYNTAX AtmEndptMapEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the ATM Endpoint Connection Mapping table." INDEX { atmEndptMapSlot, atmEndptMapPort, atmEndptMapVpi, atmEndptMapVci } ::= { atmEndptMapTable 1 } AtmEndptMapEntry ::= SEQUENCE { atmEndptMapSlot INTEGER, atmEndptMapPort INTEGER, atmEndptMapVpi INTEGER, atmEndptMapVci INTEGER, atmEndptMapEndptPtr OBJECT IDENTIFIER, atmEndptMapConnPtr OBJECT IDENTIFIER } atmEndptMapSlot OBJECT-TYPE SYNTAX INTEGER (1..32) ACCESS read-only STATUS mandatory DESCRIPTION "This MIB object contains the slot number associated with the requested connection endpoint." ::= { atmEndptMapEntry 1 } atmEndptMapPort OBJECT-TYPE SYNTAX INTEGER (1..32) ACCESS read-only STATUS mandatory DESCRIPTION "This MIB object contains the port number associated with the requested connection endpoint." ::= { atmEndptMapEntry 2 } atmEndptMapVpi OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This MIB object contains the ATM endpoint VPI associated with the requested connection endpoint." ::= { atmEndptMapEntry 3 } atmEndptMapVci OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This MIB object contains the ATM endpoint VCI associated with the requested connection endpoint." ::= { atmEndptMapEntry 4 } atmEndptMapEndptPtr OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "This MIB object contains a pointer to first column of row in the service specific EndptTable which corresponds to the slot, port, vpi, and vci specified in the columns above." ::= { atmEndptMapEntry 5 } atmEndptMapConnPtr OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "This MIB object contains a pointer to first column of row in connTable which corresponds to the slot, port, vpi, and vci specified in the columns above." ::= { atmEndptMapEntry 6 } -- -- This table defines the ATM connection end-point statistics -- Statistics are not supported on OC3 end points. The value for -- objects in this table for OC3 end points is zero. -- atmEndptStatTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmEndptStatEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The ATM End-Point Statistics table." --DEFAULT test-function test-atmendptstattable --DEFAULT next-function next-atmendptstattable --DEFAULT get-function get-atmendptstattable-%t --DEFAULT view-mask BPX-VIEW ::= { switchConnection 12 } atmEndptStatEntry OBJECT-TYPE SYNTAX AtmEndptStatEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the ATM End-point Statistics table." INDEX { atmEndptIndex } ::= { atmEndptStatTable 1 } AtmEndptStatEntry ::= SEQUENCE { atmCellsRxPorts Counter, atmFramesRxPorts Counter, atmCellsTxNets Counter, atmClpRxs Counter, atmViolRxs Counter, atmDiscardVcqClpThs Counter, atmDiscardVcqFulls Counter, atmEfciRxs Counter, atmNonCompRxs Counter, atmDiscardFails Counter, atmAvgVcqDepths Counter, atmDiscardRsrcOflows Counter, atmDiscardSbinFulls Counter, atmBcmRxs Counter, atmBcmTxs Counter, atmOamTxs Counter, atmDiscardQbinFulls Counter, atmDiscardQbinClpThs Counter, atmCellsRxNets Counter, atmClpTxs Counter, atmEfciTxs Counter, atmCellsTxPorts Counter, atmAisRxs Counter, atmFerfRxs Counter } atmCellsRxPorts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of cells delivered to the port from the line interface." ::= { atmEndptStatEntry 1 } atmFramesRxPorts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames delivered to the port from the line interface." ::= { atmEndptStatEntry 2 } atmCellsTxNets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of received cells delivered to the network." ::= { atmEndptStatEntry 3 } atmClpRxs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of cells delivered to the port from the line interface which had their CLP bit set." ::= { atmEndptStatEntry 4 } atmViolRxs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of cells that violated UPC." ::= { atmEndptStatEntry 5 } atmDiscardVcqClpThs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of cells with CLP set that were discarded due to VC queue exceeding CLP thresholds." ::= { atmEndptStatEntry 6 } atmDiscardVcqFulls OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of received cells that were discarded due to the VC queue being full." ::= { atmEndptStatEntry 7 } atmEfciRxs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of cells received with EFCI set." ::= { atmEndptStatEntry 8 } atmNonCompRxs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of non-compliant cells received." ::= { atmEndptStatEntry 9 } atmDiscardFails OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of received cells discarded due to the connection being in failed state." ::= { atmEndptStatEntry 10 } atmAvgVcqDepths OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The average queue depth of the VC queue." ::= { atmEndptStatEntry 11 } atmDiscardRsrcOflows OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of received cells discarded due to a resource overflow (e.g. cell buffer full)." ::= { atmEndptStatEntry 12 } atmDiscardSbinFulls OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of cells discarded on receipt from from the port due to Sbin full." ::= { atmEndptStatEntry 13 } atmBcmRxs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of BCM cells received from the port. This object only applies to NNI ports. For UNI ports returns 0." ::= { atmEndptStatEntry 14 } atmBcmTxs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of BCM cells transmitted to the network. This object only applies to NNI ports. For UNI ports returns 0." ::= { atmEndptStatEntry 15 } atmOamTxs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of OAM cells transmitted to the network." ::= { atmEndptStatEntry 16 } atmDiscardQbinFulls OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of cells discarded due to the egress Qbin being full." ::= { atmEndptStatEntry 17 } atmDiscardQbinClpThs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of cells with CLP set that are discarded due to the egress Qbin exceeding CLP thresholds." ::= { atmEndptStatEntry 18 } atmCellsRxNets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of cells received from the network." ::= { atmEndptStatEntry 19 } atmClpTxs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of cells transmitted to the port that had their CLP bit set." ::= { atmEndptStatEntry 20 } atmEfciTxs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of cells transmitted by the port to the line interface that had EFCI set." ::= { atmEndptStatEntry 21 } atmCellsTxPorts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of cells transmitted to the port interface." ::= { atmEndptStatEntry 22 } atmAisRxs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of received AIS cells." ::= { atmEndptStatEntry 23 } atmFerfRxs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of received FERF cells." ::= { atmEndptStatEntry 24 } -- -- The following describes the MIB variables for the voiceannelConnection. -- voiceEndptTable contains detailed information about the channel Endpoint -- connection information -- voiceChannelTable shall contain configuration information about each -- of voice Channel. -- voiceStatTable shall contains voice endpoint related statistics. voiceEndptTable OBJECT-TYPE SYNTAX SEQUENCE OF VoiceEndptEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The voice channel connection table has Channel Connection information. This table is used to model a specific Voice Channel connection. This table contains parameters which are requrired to create a Voice conneciton and configure the channel." --DEFAULT test-function test-voendpttable --DEFAULT next-function next-voendpttable --DEFAULT get-function get-voendpttable-%t --DEFAULT view-mask IPX-VIEW ::= { switchConnection 13 } voiceEndptEntry OBJECT-TYPE SYNTAX VoiceEndptEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the voice Endpoint Channel Connection table." INDEX { voiceEndptIndex } ::= { voiceEndptTable 1 } VoiceEndptEntry ::= SEQUENCE { voiceEndptIndex INTEGER, voiceOtherEndptIndex INTEGER, voiceEndptDesc DisplayString, voiceOtherEndptDesc DisplayString, voiceEndptConnDesc DisplayString, voiceEndptAdminStatus INTEGER, voiceEndptOperStatus INTEGER, voiceEndptRateType INTEGER, voiceEndPointFailure INTEGER, voiceNoRouteFoundFailure INTEGER, voiceBumpFailure INTEGER, voiceTestFailure INTEGER, voiceEndptTestType INTEGER, voiceEndptLpbkStatus INTEGER, voiceConnPtr OBJECT IDENTIFIER, voiceChannelPtr OBJECT IDENTIFIER, voiceEndptTrkAvoidType INTEGER, voiceEndptAvoidZCS INTEGER, voiceEndptState INTEGER, voiceEndptAdv INTEGER, voiceOtherEndptAdv INTEGER, voiceEndptEncoding INTEGER, voiceOtherEndptEncoding INTEGER, voiceEndptEndptType INTEGER, voiceEndptLocLpbkState INTEGER } voiceEndptIndex OBJECT-TYPE SYNTAX INTEGER (0..2047) ACCESS read-only STATUS mandatory DESCRIPTION "The index for this Voice Connection. This is the index to this table." ::= { voiceEndptEntry 1 } voiceOtherEndptIndex OBJECT-TYPE SYNTAX INTEGER (0..2047 ) ACCESS read-only STATUS mandatory DESCRIPTION "Index into remote node's voiceEndptTable for this channel end-point. For local (intra-node) connections, this index is associated with the local node and will be in the range of 1024 to 2047." ::= { voiceEndptEntry 2 } voiceEndptDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "String describing this voice Channel. Contains information about the domain, nodename, slot, channel, for the connection. For example, D1.Node1.12.1, is a valid description. Domain and nodename need not be given but slot, channel values must exist; 12.1 is valid. This variable value has to specified for a Creating an voiceEndptEntry." ::= { voiceEndptEntry 3 } voiceOtherEndptDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "String describing the remote channel. Contains information about the domain, nodename, slot, channel, for the connection. For example, D2.Node2.10.5, is a valid description. Nodename, slot, channel values must exist; Node2.10.5 is valid. This variable value has to be specified for creating an voiceEndptEntry." ::= { voiceEndptEntry 4 } voiceEndptConnDesc OBJECT-TYPE SYNTAX DisplayString ( SIZE (0..20) ) ACCESS read-write STATUS mandatory DESCRIPTION "A string that has been defined for the connection to give a more descriptive name. Connections can be given clear text names in order to make them more human readable." ::= { voiceEndptEntry 5 } voiceEndptAdminStatus OBJECT-TYPE SYNTAX INTEGER { create(1), delete(2), modify(3), test(4), writeOnly(5) } ACCESS read-write STATUS mandatory DESCRIPTION "User requested state for voice endpoint table row. A user can create / delete / modify this voice channel connection by setting this object appropriately. The user also has the capability to test a particular object. For this capability, the user must set this value to test. If a Get operation is performed on this variable, -1 shall be returned to the NMS." ::= { voiceEndptEntry 6 } voiceEndptOperStatus OBJECT-TYPE SYNTAX INTEGER { ok(1), okPendingDown(2), down(3), failed(4), inTest(5), okPendingRoute(6), okPendingDelete(7), looped(8), unknown(9) } ACCESS read-only STATUS mandatory DESCRIPTION "Actual state of the voice channel.If the state is failed, then look to the objects voiceNoRouteFoundFailure, voiceBumpFailure, and voiceTestFailure to determine reason for failure." ::= { voiceEndptEntry 7 } voiceEndptRateType OBJECT-TYPE SYNTAX INTEGER { a32(1), a24(2), a16(3), a16z(4), a32d(5), c32(6), c24(7), c16(8), c16z(9), c32d(10), p(11), t(12), v(13) } ACCESS read-write STATUS mandatory DESCRIPTION "Represents the type of voice connection. Each of them has been described below briefly. Type Description a32 Uses ADPCM only. Can select 32/24/16 Kbps a24 compression. a16 a16z Standard 16Kbps ADPCM only. compressed code can have strings of zeros and should be used on lines that have other zero code supression c32 Uses both ADPCM and Voice Activity detection (VAD). c24 Can select 32/24/16 Kbps ADPCM compression. c16 c16z Standard 16Kbps ADPCM and Voice Activity detection. Similar to 16z. Use on ZCS trunks only. p 64Kbps connection. No compression t Transparent. Clean 64Kbps connection. No Compression. This variable value has to be specified for creating an voiceEndptEntry." ::= { voiceEndptEntry 8 } voiceEndPointFailure OBJECT-TYPE SYNTAX INTEGER { false(1), true(2) } ACCESS read-only STATUS mandatory DESCRIPTION "End-point is failed because of a remote end-point failure. The remote end-point is on a node that resides in another domain making the connection an inter-domain connection." ::= { voiceEndptEntry 9 } voiceNoRouteFoundFailure OBJECT-TYPE SYNTAX INTEGER { false(1), true(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Channel connection is failed is because no route to the remote Channel could be found." ::= { voiceEndptEntry 10 } voiceBumpFailure OBJECT-TYPE SYNTAX INTEGER { false(1), true(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Channel Connection is failed because of insufficient bandwidth to route to the remote Channel. This may have also been caused because a higher priority connection took this channel's bandwidth. A higher priority connection is one with the lowest class of service (COS)." ::= { voiceEndptEntry 11 } voiceTestFailure OBJECT-TYPE SYNTAX INTEGER { false(1), true(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Channel is failed because of the failure of a connection test." ::= { voiceEndptEntry 12 } voiceEndptTestType OBJECT-TYPE SYNTAX INTEGER { testCon(1), writeOnly(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the type of test the user would like to conduct on this endpoint. Only testCon is currently defined. TestCon performs a test of voice path integrity in the connection. Only write is allowed on this object. A -1 is returned to the NMS if a GET is recevied on this object" ::= { voiceEndptEntry 13 } voiceEndptLpbkStatus OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the current Loopback State of the endpoint. The value returned from this object is a bitmap of the current loopback states associated with this end point. The bitmap is defined below: LP-RMT-RMT 0 /* Remote nodes remote muxbus loopback */ LP-RMT-TST 1 /* Remote nodes tstcon loopback */ LP-LOC-RMT 2 /* Local nodes remote muxbus loopback */ LP-LOC-TST 3 /* Local nodes tstcon loopback */ LP-LOC-LOC 4 /* Local nodes local muxbus loopback */ LP-LOC-PORT 5 /* Local nodes port loopback */ LP-LOC-TPORT 6 /* Local nodes port test loopback */ LP-RMT-LOC 7 /* Remote nodes local muxbus loopback */ LP-RMT-PORT 8 /* Remote nodes port loopback */ LP-RMT-TPORT 9 /* Remote nodes port test looback */ LP-LOC-CSU 10 /* Local DDS network requested CSU loopback */ LP-RMT-CSU 11 /* Remote DDS network requested CSU loopback */ LP-LOC-DSU 12 /* Local DDS network requested DSU loopback */ LP-RMT-DSU 13 /* Remote DDS network requested DSU loopback */ LP-LOC-EXT 14 /* Local DDS external loopback */ LP-RMT-EXT 15 /* Remote DDS external loopback */ " ::= { voiceEndptEntry 14 } voiceConnPtr OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "Pointer to general connection information. Using this pointer the user can obtain connection status, and routing information. Specifically, this is an object identifier specifying the first column of the appropriate row in the connTable." ::= { voiceEndptEntry 15 } voiceChannelPtr OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "Pointer to channel configuration information. Using this pointer the user can obtain all channel configuration information. Specifically, this is an object identifier specifying the first column of the appropriate row in the voiceChannelTable. " ::= { voiceEndptEntry 16 } voiceEndptTrkAvoidType OBJECT-TYPE SYNTAX INTEGER { none(1), satellite(2), terrestrial(3) } ACCESS read-write STATUS mandatory DESCRIPTION "User selectable types of trunks to avoid for the transfer of voice channel data. Current choices are to avoid satellite links, terrestrial links, or to not avoid any specific type of link. This object is optional during the creation of the endpoint." ::= { voiceEndptEntry 17 } voiceEndptAvoidZCS OBJECT-TYPE SYNTAX INTEGER { false(1), true(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Flag to force the connection to avoid trunks with zero code suppression (ZCS). This object is optional during the creation of the endpoint." ::= { voiceEndptEntry 18 } voiceEndptState OBJECT-TYPE SYNTAX INTEGER { offhook (1), onhook(2), slowmodem(3), fastmodem(4), notConnected(5) } ACCESS read-only STATUS mandatory DESCRIPTION "It gives the state of the connection end point." ::= { voiceEndptEntry 19 } voiceEndptAdv OBJECT-TYPE SYNTAX INTEGER { false(1), true(2) } ACCESS read-only STATUS mandatory DESCRIPTION "It represents if the endpoint supports Adaptve voice capability." ::= { voiceEndptEntry 20 } voiceOtherEndptAdv OBJECT-TYPE SYNTAX INTEGER { false(1), true(2) } ACCESS read-only STATUS mandatory DESCRIPTION "It represents if the other endpoint supports Adaptve voice capability." ::= { voiceEndptEntry 21 } voiceEndptEncoding OBJECT-TYPE SYNTAX INTEGER { alaw(1), ulaw(2) } ACCESS read-only STATUS mandatory DESCRIPTION "It represents the type of Encoding used at this this Endpoint." ::= { voiceEndptEntry 22 } voiceOtherEndptEncoding OBJECT-TYPE SYNTAX INTEGER { alaw(1), ulaw(2) } ACCESS read-only STATUS mandatory DESCRIPTION "It represents the type of Encoding used at the other Endpoint." ::= { voiceEndptEntry 23 } voiceEndptEndptType OBJECT-TYPE SYNTAX INTEGER { pcm(1), adpcm(2), adpno(3), transp(4), unknown(5) } ACCESS read-only STATUS mandatory DESCRIPTION "It represents the end point type" ::= { voiceEndptEntry 24 } voiceEndptLocLpbkState OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2), writeOnly(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the Local Loopback State the user would like to set for the endpoint." ::= { voiceEndptEntry 25 } -- -- Voice End Point Statistics Table -- voiceStatTable OBJECT-TYPE SYNTAX SEQUENCE OF VoiceStatEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The voice Statistics Table." --DEFAULT test-function test-voicestatstable --DEFAULT next-function next-voicestatstable --DEFAULT get-function get-voicestatstable-%t --DEFAULT view-mask IPX-VIEW ::= { switchConnection 14 } voiceStatEntry OBJECT-TYPE SYNTAX VoiceStatEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the voice channel statistics table." INDEX { voiceEndptIndex } ::= { voiceStatTable 1 } VoiceStatEntry ::= SEQUENCE { voiceStatPktsRxs Counter, voiceStatPktsXmits Counter, voiceStatRxPktsDscds Counter, voiceStatSprvPktsXmits Counter, voiceStatSprvPktsRcvs Counter, voiceStatV25ModemOns Counter, voiceStatDsiOns Counter, voiceStatOffhks Counter, voiceStatInservices Counter } voiceStatPktsRxs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets received from the muxbus by the local port card." ::= { voiceStatEntry 1 } voiceStatPktsXmits OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets transmitted from the local port card onto the Mux Bus." ::= { voiceStatEntry 2 } voiceStatRxPktsDscds OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets received from the muxbus by the local port card which are discarded before being transmitted out to the port." ::= { voiceStatEntry 3 } voiceStatSprvPktsXmits OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of supervisory packets transmitted from the local port onto the Muxbus. Supervisory packets reflect signalling bit transitions for voice connections." ::= { voiceStatEntry 4 } voiceStatSprvPktsRcvs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of supervisory packets received from Muxbus associated with a connection." ::= { voiceStatEntry 5 } voiceStatV25ModemOns OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of seconds the V.25 modem is detected and the connection is upgraded to PCM." ::= { voiceStatEntry 6 } voiceStatDsiOns OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of seconds that a connection is performing Digital speech interpolation (DSI)." ::= { voiceStatEntry 7 } voiceStatOffhks OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of seconds that a connection is offhook. The onhook state is determined by onhook A/B/C/D bits defined by variables in the voiceEndpttable. A connection which is not onhook is treated as offhook." ::= { voiceStatEntry 8 } voiceStatInservices OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of seconds a connection is inservice. A connection is said to be in-service if its endpoints are not in alarm, the cards required to support this connection are present, and the connection is routed." ::= { voiceStatEntry 9 } -- -- This table describes a mapping between voice endpoints -- described by slot.channel and corresponding object identifier -- pointers into connTable and the service specific endptTable. -- This table allows the user to determine the table indeces associated -- with the connection defined by the physical attributes of slot and -- channel. -- voiceEndptMapTable OBJECT-TYPE SYNTAX SEQUENCE OF VoiceEndptMapEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Voice Endpoint-Connection Mapping table." --DEFAULT test-function test-voendptmaptable --DEFAULT next-function next-voendptmaptable --DEFAULT get-function get-voendptmaptable-%t --DEFAULT view-mask IPX-VIEW ::= { switchConnection 15 } voiceEndptMapEntry OBJECT-TYPE SYNTAX VoiceEndptMapEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Voice Endpoint Connection Mapping table." INDEX { voiceEndptMapSlot, voiceEndptMapChannel } ::= { voiceEndptMapTable 1 } VoiceEndptMapEntry ::= SEQUENCE { voiceEndptMapSlot INTEGER, voiceEndptMapChannel INTEGER, voiceEndptMapEndptPtr OBJECT IDENTIFIER, voiceEndptMapConnPtr OBJECT IDENTIFIER } voiceEndptMapSlot OBJECT-TYPE SYNTAX INTEGER (1..32) ACCESS read-only STATUS mandatory DESCRIPTION "This MIB object contains the slot number associated with the requested connection endpoint." ::= { voiceEndptMapEntry 1 } voiceEndptMapChannel OBJECT-TYPE SYNTAX INTEGER (1..32) ACCESS read-only STATUS mandatory DESCRIPTION "This MIB object contains the channel number associated with the requested connection endpoint." ::= { voiceEndptMapEntry 2 } voiceEndptMapEndptPtr OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "This MIB object contains a pointer to first column of row in the service specific EndptTable which corresponds to the slot and channel specified in the columns above." ::= { voiceEndptMapEntry 3 } voiceEndptMapConnPtr OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "This MIB object contains a pointer to first column of row in connTable which corresponds to the slot and channel specified in the columns above." ::= { voiceEndptMapEntry 4 } -- The following objects are associated with the switchShelf -- configuration branch. These objects are scalar variables -- utilized by the network manager to manage the switch shelf -- wide configuration. shelfCnfgStatMaster OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the network manager the IP address of the master statistics collection management workstation." --DEFAULT get-function get-shelf-statmaster ::= { shelfCnfgObjects 1 } shelfCnfgStatCollIntvl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the network manager the current TFTP statistics collection file interval configured on the switch in minutes." --DEFAULT get-function get-shelf-statparm ::= { shelfCnfgObjects 2 } shelfCnfgStatBcktIntvl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the network manager the current TFTP statistics collection bucket interval configured on the switch in minutes." --DEFAULT get-function get-shelf-statparm ::= { shelfCnfgObjects 3 } shelfCnfgStatTimeSync OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the network manager the current time for TFTP statistics collection. This object replaces the functionality originally supplied by the daytime handler application." --DEFAULT get-function get-shelf-time ::= { shelfCnfgObjects 4 } shelfCnfgSwError OBJECT-TYPE SYNTAX INTEGER { false(1), true(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This object notifies the network manager that a switch software error has has been logged on this shelf." --DEFAULT get-function get-shelf-errors ::= { shelfCnfgObjects 5 } shelfCnfgCardError OBJECT-TYPE SYNTAX INTEGER { false(1), true(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This object notifies the network manager that a switch card error has has been logged on this shelf." --DEFAULT get-function get-shelf-errors ::= { shelfCnfgObjects 6 } -- END -- -- Stratacom StrataView Network MIBs -- -- $RCSfile: SV+Network.mib,v $ -- $Revision: 1.1.4.20 $ -- $Date: 1996/06/26 22:43:28 $ -- -- Consolidated MIB for event, node, filters, rtc and rtm -- -- -- STRATACOM-STRATAVIEW-SVPLUS-MIB -- DEFINITIONS ::= BEGIN -- IMPORTS -- enterprises, Counter, IpAddress FROM RFC1155-SMI -- DisplayString FROM RFC1213-MIB -- TRAP-TYPE FROM RFC-1215 -- OBJECT-TYPE FROM RFC-1212; -- stratacom OBJECT IDENTIFIER ::= { enterprises 351 } svplus OBJECT IDENTIFIER ::= { stratacom 1 } svnode OBJECT IDENTIFIER ::= { stratacom 2 } -- connSvc OBJECT IDENTIFIER ::= { stratacom 3 } -- portSvc OBJECT IDENTIFIER ::= { stratacom 4 } rtm OBJECT IDENTIFIER ::= { stratacom 120 } -- strmErrors OBJECT IDENTIFIER ::= { stratacom 910 } -- StrataView Plus Generated events. Added br HJ and Sridhar strataviewEvents OBJECT IDENTIFIER ::= { stratacom 920 } -- -- Note that Object identifiers { svplus 1 } through { svplus 10 } -- have been depricated. controlGroup OBJECT IDENTIFIER ::= { svplus 11 } logGroup OBJECT IDENTIFIER ::= { svplus 12 } networkGroup OBJECT IDENTIFIER ::= { svplus 13 } nodeGroup OBJECT IDENTIFIER ::= { svplus 14 } svNodeGroup OBJECT IDENTIFIER ::= { svnode 1 } packetGroup OBJECT IDENTIFIER ::= { svnode 2 } circuitGroup OBJECT IDENTIFIER ::= { svnode 3 } frpGroup OBJECT IDENTIFIER ::= { svnode 4 } connGroup OBJECT IDENTIFIER ::= { svnode 5 } realTimeCountersGroup OBJECT IDENTIFIER ::= { svnode 6 } trapsConfig OBJECT IDENTIFIER ::= { rtm 1 } Active ::= INTEGER { inactive (1), active (2) } -- Values currently used for "severity" in log records and -- TRAP filters are "Clear", "Info", "Minor", "Major", and -- "Updt" (for update). Others may be used in the future. -- Severity ::= DisplayString (SIZE (0..5)) nodeGrpName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..10)) ACCESS read-only -- C-STRUCT node-cfg, FIELD nodeName -- C-LOCATOR-FUNC NodeMibNodeLocator STATUS mandatory DESCRIPTION "IPX node name." ::= { svNodeGroup 1 } nodeGrpNetName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..10)) ACCESS read-only -- C-ACCESS-FUNC NodeMibNetName STATUS mandatory DESCRIPTION "IPX network name." ::= { svNodeGroup 2 } nodeGrpAlarmState OBJECT-TYPE SYNTAX INTEGER { clear (1), minor (2), major (3), unreachable (5) } ACCESS read-only -- C-STRUCT node-cfg, FIELD nodeAlarmState -- C-LOCATOR-FUNC NodeMibNodeLocator STATUS mandatory DESCRIPTION "Node Alarm State. Only low 6 bits are valid." ::= { svNodeGroup 3 } nodeGrpGateway OBJECT-TYPE SYNTAX INTEGER { not-a-gateway (1), gateway (2) } ACCESS read-only -- C-STRUCT node-cfg, FIELD nodeGateway -- C-LOCATOR-FUNC NodeMibNodeLocator STATUS mandatory DESCRIPTION "Is this node acting as a gateway?" ::= { svNodeGroup 4 } nodeGrpActive OBJECT-TYPE SYNTAX Active ACCESS read-only -- C-STRUCT node-cfg, FIELD nodeActive -- C-LOCATOR-FUNC NodeMibNodeLocator STATUS mandatory DESCRIPTION "Active state of this Node." ::= { svNodeGroup 5 } nodeGrpPlatform OBJECT-TYPE SYNTAX INTEGER { ipx-platform (1), bpx-platform (2), axis-platform (3) } ACCESS read-only -- C-STRUCT node-cfg, FIELD nodePlatform -- C-LOCATOR-FUNC NodeMibNodeLocator STATUS mandatory DESCRIPTION "Platform type." ::= { svNodeGroup 6 } nodeGrpRelease OBJECT-TYPE SYNTAX DisplayString (SIZE(0..10)) ACCESS read-only -- C-STRUCT node-cfg, FIELD nodeRelease -- C-LOCATOR-FUNC NodeMibNodeLocator STATUS mandatory DESCRIPTION "StrataView Plus release revison." ::= { svNodeGroup 7 } nodeFsIncRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT node-cfg, FIELD nodeFsIncRate -- C-LOCATOR-FUNC NodeMibNodeLocator STATUS mandatory DESCRIPTION "FRP Foresight increase rate." ::= { svNodeGroup 8 } nodeFsDecRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT node-cfg, FIELD nodeFsDecRate -- C-LOCATOR-FUNC NodeMibNodeLocator STATUS mandatory DESCRIPTION "FRP forsight normal decrease rate." ::= { svNodeGroup 9 } nodeFsFastRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT node-cfg, FIELD nodeFsFastRate -- C-LOCATOR-FUNC NodeMibNodeLocator STATUS mandatory DESCRIPTION "FRP forsight fast decrease rate." ::= { svNodeGroup 10 } nodeRstTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT node-cfg, FIELD nodeRstTimeout -- C-LOCATOR-FUNC NodeMibNodeLocator STATUS mandatory DESCRIPTION "Timeout for resetting PVC rate to QIR." ::= { svNodeGroup 11 } alarmTrapSequenceNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT proxy-ctxt, FIELD lastTrapSeqNum STATUS mandatory DESCRIPTION "The Sequence Number of the last trap generated on the SNMP Proxy" ::= { svNodeGroup 12 } ----------------------------------------------------------------------- -- Packet Group ----------------------------------------------------------------------- ----------------------------------------------------------------------- -- Packet Line Table has been deleted and replaced by the Trunk Table. ----------------------------------------------------------------------- --pktLineTable OBJECT-TYPE -- SYNTAX SEQUENCE OF PktLineEntry -- ACCESS not-accessible -- STATUS mandatory -- DESCRIPTION "The table of Packet Lines." -- ::= { packetGroup 1 } ----------------------------------------------------------------------- -- Trunk Table ----------------------------------------------------------------------- trunkTable OBJECT-TYPE SYNTAX SEQUENCE OF TrunkEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table of Trunk Lines." ::= { packetGroup 2 } trunkEntry OBJECT-TYPE SYNTAX TrunkEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Trunk table." INDEX { trunkLocalSlot, trunkLocalPort } -- C-NEXT-FUNC trunk-next ::= { trunkTable 1 } TrunkEntry ::= SEQUENCE { trunkLocalSlot INTEGER, trunkLocalPort INTEGER, trunkLocalLine INTEGER, trunkCardType INTEGER, trunkInterface INTEGER, trunkLineLoad INTEGER, trunkRemNodeId INTEGER, trunkRemLineNumber INTEGER, trunkRemSlot INTEGER, trunkRemPort INTEGER, trunkAlarmState INTEGER, trunkComment DisplayString, trunkActive Active, trunkStatus INTEGER, trunkStatReserve INTEGER, trunkBurstyDataBQDepth INTEGER, trunkBurstyDataBQEfcnThreshold INTEGER, trunkClpHighDropThreshold INTEGER, trunkClpLowDropThreshold INTEGER } trunkLocalSlot OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT trunk-cfg, FIELD trunkLocalSlot -- C-LOCATOR-FUNC trunk-locator STATUS mandatory DESCRIPTION "Local Slot Number. These are numbered starting at 1." ::= { trunkEntry 1 } trunkLocalPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT trunk-cfg, FIELD trunkLocalPort -- C-LOCATOR-FUNC trunk-locator STATUS mandatory DESCRIPTION "Local Port Number. These are numbered starting at 1." ::= { trunkEntry 2 } trunkLocalLine OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT trunk-cfg, FIELD trunkLineNumber -- C-LOCATOR-FUNC trunk-locator STATUS mandatory DESCRIPTION "Local Line Number. These are numbered starting at 1." ::= { trunkEntry 3 } trunkCardType OBJECT-TYPE SYNTAX INTEGER { txr(3), bni(4), ntc(22), atm(31), ait(34), bni-t3(103), bni-e3(104), bni-oc3(110) } ACCESS read-only -- C-STRUCT trunk-cfg, FIELD trunkCardType -- C-LOCATOR-FUNC trunk-locator STATUS mandatory DESCRIPTION "Type of the card supporting the trunk line. The card type is dependant on the value of nodePlatform. Additional types may exist with future hardware." ::= { trunkEntry 4 } trunkInterface OBJECT-TYPE SYNTAX INTEGER { unknown (1), t1-d4 (2), t1-esf (3), e1-30 (4), e1-31 (5), e1-32 (6), subrate (7), atm (8) } ACCESS read-only -- C-STRUCT trunk-cfg, FIELD trunkInterface -- C-LOCATOR-FUNC trunk-locator STATUS mandatory DESCRIPTION "Trunk Line Interface Type. Indicates the format of the packet line." ::= { trunkEntry 5 } trunkLineLoad OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT trunk-cfg, FIELD trunkLineLoad -- C-LOCATOR-FUNC trunk-locator STATUS mandatory DESCRIPTION "Line Load in packets per second." ::= { trunkEntry 6 } trunkRemNodeId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT trunk-cfg, FIELD trunkRemNodeId -- C-LOCATOR-FUNC trunk-locator STATUS mandatory DESCRIPTION "Remote StrataView Node ID." ::= { trunkEntry 7 } trunkRemLineNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT trunk-cfg, FIELD trunkRemLineNumber -- C-LOCATOR-FUNC trunk-locator STATUS mandatory DESCRIPTION "Remote Line Number." ::= { trunkEntry 8 } trunkRemSlot OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT trunk-cfg, FIELD trunkRemSlot -- C-LOCATOR-FUNC trunk-locator STATUS mandatory DESCRIPTION "Remote Slot Number." ::= { trunkEntry 9 } trunkRemPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT trunk-cfg, FIELD trunkRemPort -- C-LOCATOR-FUNC trunk-locator STATUS mandatory DESCRIPTION "Remote Port Number." ::= { trunkEntry 10 } trunkAlarmState OBJECT-TYPE SYNTAX INTEGER { clear (1), minor (2), major (3) } ACCESS read-only -- C-STRUCT trunk-cfg, FIELD trunkAlarmState -- C-LOCATOR-FUNC trunk-locator STATUS mandatory DESCRIPTION "Trunk Line Alarm State." ::= { trunkEntry 11 } trunkComment OBJECT-TYPE SYNTAX DisplayString (SIZE(0..20)) ACCESS read-only -- C-STRUCT trunk-cfg, FIELD trunkComment -- C-LOCATOR-FUNC trunk-locator STATUS mandatory DESCRIPTION "StrataView user entered comment field used to further qualify the trunk line." ::= { trunkEntry 12 } trunkActive OBJECT-TYPE SYNTAX Active ACCESS read-only -- C-STRUCT trunk-cfg, FIELD trunkActive -- C-LOCATOR-FUNC trunk-locator STATUS mandatory DESCRIPTION "Active State." ::= { trunkEntry 13 } trunkStatus OBJECT-TYPE SYNTAX INTEGER { inactive(1), clear(2), fail(3), down(4) } ACCESS read-only -- C-STRUCT trunk-cfg, FIELD trunkStatus -- C-LOCATOR-FUNC trunk-locator STATUS mandatory DESCRIPTION "Trunk line status." ::= { trunkEntry 14 } trunkStatReserve OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT trunk-cfg, FIELD trunkStatReserve -- C-LOCATOR-FUNC trunk-locator STATUS mandatory DESCRIPTION "Trunk Line statistical reserve field." ::= { trunkEntry 15 } trunkBurstyDataBQDepth OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT trunk-cfg, FIELD trunkBurstyDataBQDepth -- C-LOCATOR-FUNC trunk-locator STATUS mandatory DESCRIPTION "Trunk Line bursty data B queue depth." ::= { trunkEntry 16 } trunkBurstyDataBQEfcnThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT trunk-cfg, FIELD trunkBurstyDataBQEfcnThreshold -- C-LOCATOR-FUNC trunk-locator STATUS mandatory DESCRIPTION "Trunk Line bursty data B queue EFCN/FFCI threshold." ::= { trunkEntry 17 } trunkClpHighDropThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT trunk-cfg, FIELD trunkClpHighDropThreshold -- C-LOCATOR-FUNC trunk-locator STATUS mandatory DESCRIPTION "Trunk Line CLP high dropping threshold." ::= { trunkEntry 18 } trunkClpLowDropThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT trunk-cfg, FIELD trunkClpLowDropThreshold -- C-LOCATOR-FUNC trunk-locator STATUS mandatory DESCRIPTION "Trunk Line CLP low dropping threshold." ::= { trunkEntry 19 } ----------------------------------------------------------------------- -- Circuit Group ----------------------------------------------------------------------- ----------------------------------------------------------------------- -- Circuit Line Table -- ASI Lines are not supported in this MIB table. ----------------------------------------------------------------------- cirLineTable OBJECT-TYPE SYNTAX SEQUENCE OF CirLineEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table of Circuit Lines." ::= { circuitGroup 1 } cirLineEntry OBJECT-TYPE SYNTAX CirLineEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Circuit Line table." INDEX { cirLineLineNumber, cirLinePortNumber } -- C-NEXT-FUNC cirLine-next ::= { cirLineTable 1 } CirLineEntry ::= SEQUENCE { cirLineLineNumber INTEGER, cirLineCardType INTEGER, cirLineInterface INTEGER, cirLineComment DisplayString, cirLineActive Active, cirLineStatus INTEGER, cirLinePortNumber INTEGER } cirLineLineNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT cir-line-cfg, FIELD cirLineLineNumber -- C-LOCATOR-FUNC cirLine-locator STATUS mandatory DESCRIPTION "Circuit Line Number." ::= { cirLineEntry 3 } cirLineCardType OBJECT-TYPE SYNTAX INTEGER { txr (3), cip (21), frp (25), cdp (29) } ACCESS read-only -- C-STRUCT cir-line-cfg, FIELD cirLineCardType -- C-LOCATOR-FUNC cirLine-locator STATUS mandatory DESCRIPTION "Circuit Card Type." ::= { cirLineEntry 4 } cirLineInterface OBJECT-TYPE SYNTAX INTEGER { unknown (1), t1 (2), e1 (3) } ACCESS read-only -- C-STRUCT cir-line-cfg, FIELD cirLineInterface -- C-LOCATOR-FUNC cirLine-locator STATUS mandatory DESCRIPTION "Circuit Line Interface Type. Indicates the format of the circuit line." ::= { cirLineEntry 5 } cirLineComment OBJECT-TYPE SYNTAX DisplayString (SIZE(0..22)) ACCESS read-only -- C-STRUCT cir-line-cfg, FIELD cirLineComment -- C-LOCATOR-FUNC cirLine-locator STATUS mandatory DESCRIPTION "Comment entered by StrataView user to further qualify the Circuit Line." ::= { cirLineEntry 6 } cirLineActive OBJECT-TYPE SYNTAX Active ACCESS read-only -- C-STRUCT cir-line-cfg, FIELD cirLineActive -- C-LOCATOR-FUNC cirLine-locator STATUS mandatory DESCRIPTION "Circuit Line Active State." ::= { cirLineEntry 7 } cirLineStatus OBJECT-TYPE SYNTAX INTEGER { inactive(1), clear(2), fail(3), down(4) } ACCESS read-only -- C-STRUCT cir-line-cfg, FIELD cirLineStatus -- C-LOCATOR-FUNC cirLine-locator STATUS mandatory DESCRIPTION "Circuit Line Status." ::= { cirLineEntry 8 } cirLinePortNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT cir-line-cfg, FIELD cirLinePortNumber -- C-LOCATOR-FUNC cirLine-locator STATUS mandatory DESCRIPTION "Always returned as 0 for GET requests. ASI port number is filled-in for TRAPs." ::= { cirLineEntry 9 } ----------------------------------------------------------------------- -- Frame Relay Port Group ----------------------------------------------------------------------- ----------------------------------------------------------------------- -- Frame Relay Port Table ----------------------------------------------------------------------- frpTable OBJECT-TYPE SYNTAX SEQUENCE OF FrpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table of Frame Relay Ports." ::= { frpGroup 1 } frpEntry OBJECT-TYPE SYNTAX FrpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Frame Relay Ports table." INDEX { frpLocalSlot, frpLocalLine, frpLocalPort } -- C-NEXT-FUNC frp-next ::= { frpTable 1 } FrpEntry ::= SEQUENCE { frpLocalSlot INTEGER, frpLocalPort INTEGER, frpPortSpeed INTEGER, frpComment DisplayString, frpActive Active, frpStatus INTEGER, frpQDepth INTEGER, frpEcnThreshold INTEGER, frpDeThreshold INTEGER, frpPortType INTEGER, frpLocalLine INTEGER } frpLocalSlot OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT frp-cfg, FIELD frpLocalSlot -- C-LOCATOR-FUNC frp-locator STATUS mandatory DESCRIPTION "Local Slot Number." ::= { frpEntry 3 } frpLocalPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT frp-cfg, FIELD frpLocalPort -- C-LOCATOR-FUNC frp-locator STATUS mandatory DESCRIPTION "Local Port Number. These are numbered starting at 1." ::= { frpEntry 4 } frpPortSpeed OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT frp-cfg, FIELD frpPortSpeed -- C-LOCATOR-FUNC frp-locator STATUS mandatory DESCRIPTION "Port Speed in bits per second." ::= { frpEntry 5 } frpComment OBJECT-TYPE SYNTAX DisplayString (SIZE(0..22)) ACCESS read-only -- C-STRUCT frp-cfg, FIELD frpComment -- C-LOCATOR-FUNC frp-locator STATUS mandatory DESCRIPTION "StrataView User comment used to further qualify the Frame Relay Port." ::= { frpEntry 6 } frpActive OBJECT-TYPE SYNTAX Active ACCESS read-only -- C-STRUCT frp-cfg, FIELD frpActive -- C-LOCATOR-FUNC frp-locator STATUS mandatory DESCRIPTION "Frame Relay Port Active State." ::= { frpEntry 7 } frpStatus OBJECT-TYPE SYNTAX INTEGER { inactive(1), clear(2), fail(3), down(4) } ACCESS read-only -- C-STRUCT frp-cfg, FIELD frpStatus -- C-LOCATOR-FUNC frp-locator STATUS mandatory DESCRIPTION "Frame Relay Port Status." ::= { frpEntry 8 } frpQDepth OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT frp-cfg, FIELD frpQDepth -- C-LOCATOR-FUNC frp-locator STATUS mandatory DESCRIPTION "Frame Relay Port queue depth." ::= { frpEntry 9 } frpEcnThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT frp-cfg, FIELD frpEcnThreshold -- C-LOCATOR-FUNC frp-locator STATUS mandatory DESCRIPTION "Frame Relay Port ECN queue threshold." ::= { frpEntry 10 } frpDeThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT frp-cfg, FIELD frpDeThreshold -- C-LOCATOR-FUNC frp-locator STATUS mandatory DESCRIPTION "Frame Relay Port DE threshold." ::= { frpEntry 11 } frpPortType OBJECT-TYPE SYNTAX INTEGER { uni(1), nni(2), aip(3), not-defined(4), frsm(5), portConcent(6) } ACCESS read-only -- C-STRUCT frp-cfg, FIELD frpPortType -- C-LOCATOR-FUNC frp-locator STATUS mandatory DESCRIPTION "Frame relay port type. " ::= { frpEntry 12 } frpLocalLine OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT frp-cfg, FIELD frpLocalLine -- C-LOCATOR-FUNC frp-locator STATUS mandatory DESCRIPTION "Local Line Number." ::= { frpEntry 13 } ----------------------------------------------------------------------- -- Connection Group ----------------------------------------------------------------------- ----------------------------------------------------------------------- -- Connection Table ----------------------------------------------------------------------- connServerTable OBJECT-TYPE SYNTAX SEQUENCE OF ConnEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table of Connections." ::= { connGroup 1 } connEntry OBJECT-TYPE SYNTAX ConnEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Connections table." INDEX { connLocalSlot, connLocalLine, connLocalChannel, connLocalDLCI } -- C-NEXT-FUNC conn-next ::= { connServerTable 1 } ConnEntry ::= SEQUENCE { connLocalSlot INTEGER, connLocalChannel INTEGER, connLocalDLCI INTEGER, connRemoteNodeId INTEGER, connRemoteSlot INTEGER, connRemoteChannel INTEGER, connRemoteDLCI INTEGER, connServerType INTEGER, connRate INTEGER, connLocalMaxPkts INTEGER, connRemoteMaxPkts INTEGER, connMinBandwidth INTEGER, connDAX INTEGER, connTXR INTEGER, connComment DisplayString, connActive Active, connStatus INTEGER, connQir INTEGER, connPir INTEGER, connVcQueDepth INTEGER, connVcQueThreshold INTEGER, connCMax INTEGER, connPerUtil INTEGER, connConnInfoFlag INTEGER, connCir INTEGER, connABitStatus INTEGER, connLocalLine INTEGER } connLocalSlot OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT connection-cfg, FIELD connLocalSlot -- C-LOCATOR-FUNC conn-locator STATUS mandatory DESCRIPTION "Local Slot Number." ::= { connEntry 3 } connLocalChannel OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT connection-cfg, FIELD connLocalChannel -- C-LOCATOR-FUNC conn-locator STATUS mandatory DESCRIPTION "Local Channel Number. These are numbered starting at 1." ::= { connEntry 4 } connLocalDLCI OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT connection-cfg, FIELD connLocalDLCI -- C-LOCATOR-FUNC conn-locator STATUS mandatory DESCRIPTION "Local DLCI Number." ::= { connEntry 5 } connRemoteNodeId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT connection-cfg, FIELD connRemoteNodeId -- C-LOCATOR-FUNC conn-locator STATUS mandatory DESCRIPTION "Remote StrataView Node ID." ::= { connEntry 6 } connRemoteSlot OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT connection-cfg, FIELD connRemoteSlot -- C-LOCATOR-FUNC conn-locator STATUS mandatory DESCRIPTION "Remote Slot Number." ::= { connEntry 7 } connRemoteChannel OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT connection-cfg, FIELD connRemoteChannel -- C-LOCATOR-FUNC conn-locator STATUS mandatory DESCRIPTION "Remote Channel Number. These are numbered starting at 1." ::= { connEntry 8 } connRemoteDLCI OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT connection-cfg, FIELD connRemoteDLCI -- C-LOCATOR-FUNC conn-locator STATUS mandatory DESCRIPTION "Remote DLCI Number." ::= { connEntry 9 } connServerType OBJECT-TYPE SYNTAX INTEGER { voice-dsi-adpcm (1), voice-dsi (2), voice (3), voice-adpcm (4), data (5), frame-relay (6) } ACCESS read-only -- C-STRUCT connection-cfg, FIELD connType -- C-LOCATOR-FUNC conn-locator STATUS mandatory DESCRIPTION "Connection Type." ::= { connEntry 10 } connRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT connection-cfg, FIELD connRate -- C-LOCATOR-FUNC conn-locator STATUS mandatory DESCRIPTION "Combination Field of Rate Info. The value for this variable is generated by ORing together the following: 0x80 -> Fast Eia Enabled 0x40 -> DFM Enabled 0x08 -> 7/8 Encoding 0x10 -> 8/8 Encoding 0x18 -> 8/8 Inverted Encoding 0x20 -> 7/8 Inverted Encoding 0x01 -> Voice 0x02 -> Non-Time Stamped 0x03 -> Time Stamped 0x04 -> bursty data 0x05 -> multicast These form four fields: bit 7, bit 6, bits 3-5, and bits 0-2." ::= { connEntry 11 } connLocalMaxPkts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT connection-cfg, FIELD connLocalMaxPkts -- C-LOCATOR-FUNC conn-locator STATUS mandatory DESCRIPTION "Local maximum number of packets per second allocated." ::= { connEntry 12 } connRemoteMaxPkts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT connection-cfg, FIELD connRemoteMaxPkts -- C-LOCATOR-FUNC conn-locator STATUS mandatory DESCRIPTION "Remote maximum number of packets per second allocated." ::= { connEntry 13 } connMinBandwidth OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT connection-cfg, FIELD connMinBandwidth -- C-LOCATOR-FUNC conn-locator STATUS mandatory DESCRIPTION "Minimum guaranteed bandwidth in bits per second. Zero if not meaningful." ::= { connEntry 14 } connDAX OBJECT-TYPE SYNTAX INTEGER { non-dax(1), dax(2) } ACCESS read-only -- C-STRUCT connection-cfg, FIELD connDAX -- C-LOCATOR-FUNC conn-locator STATUS mandatory DESCRIPTION "Flag to identify DAX connection." ::= { connEntry 15 } connTXR OBJECT-TYPE SYNTAX INTEGER { non-txr(1), txr(2) } ACCESS read-only -- C-STRUCT connection-cfg, FIELD connTXR -- C-LOCATOR-FUNC conn-locator STATUS mandatory DESCRIPTION "Flag to identify voice connection end point card is TXR card type." ::= { connEntry 16 } connComment OBJECT-TYPE SYNTAX DisplayString (SIZE(0..22)) ACCESS read-only -- C-STRUCT connection-cfg, FIELD connComment -- C-LOCATOR-FUNC conn-locator STATUS mandatory DESCRIPTION "StrataView user entered comment field used to further qualify the connection." ::= { connEntry 17 } connActive OBJECT-TYPE SYNTAX Active ACCESS read-only -- C-STRUCT connection-cfg, FIELD connActive -- C-LOCATOR-FUNC conn-locator STATUS mandatory DESCRIPTION "Connection Active State." ::= { connEntry 18 } connStatus OBJECT-TYPE SYNTAX INTEGER { inactive(1), clear(2), fail(3), down(4) } ACCESS read-only -- C-STRUCT connection-cfg, FIELD connLineStatus -- C-LOCATOR-FUNC conn-locator STATUS mandatory DESCRIPTION "Connection Status." ::= { connEntry 19 } connQir OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT connection-cfg, FIELD connQir -- C-LOCATOR-FUNC conn-locator STATUS mandatory DESCRIPTION "Connection QIR.(bits per sec)" ::= { connEntry 20 } connPir OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT connection-cfg, FIELD connPir -- C-LOCATOR-FUNC conn-locator STATUS mandatory DESCRIPTION "Connection PIR.(bits per sec)" ::= { connEntry 21 } connVcQueDepth OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT connection-cfg, FIELD connVcQueDepth -- C-LOCATOR-FUNC conn-locator STATUS mandatory DESCRIPTION "Connection VcQueDepth." ::= { connEntry 22 } connVcQueThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT connection-cfg, FIELD connVcQueThresh -- C-LOCATOR-FUNC conn-locator STATUS mandatory DESCRIPTION "Connection VcQueThreshold." ::= { connEntry 23 } connCMax OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT connection-cfg, FIELD connCMax -- C-LOCATOR-FUNC conn-locator STATUS mandatory DESCRIPTION "Connection maximum threshold for FRP credit manager." ::= { connEntry 24 } connPerUtil OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT connection-cfg, FIELD connPerUtil -- C-LOCATOR-FUNC conn-locator STATUS mandatory DESCRIPTION "Connection Percent utilization." ::= { connEntry 25 } connConnInfoFlag OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT connection-cfg, FIELD connConnInfoFlag -- C-LOCATOR-FUNC conn-locator STATUS mandatory DESCRIPTION "Connection information flags. The flags are define as: bit 6 snaPriorityHigh - decimal 64 bit 7 forsightEnabled - decimal 128 A value of 0 indicates no bits are set." ::= { connEntry 26 } connCir OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT connection-cfg, FIELD connCir -- C-LOCATOR-FUNC conn-locator STATUS mandatory DESCRIPTION "Connection CIR.(bits per sec)" ::= { connEntry 27 } connABitStatus OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT connection-cfg, FIELD connABitStatus -- C-LOCATOR-FUNC conn-locator STATUS mandatory DESCRIPTION "Connection Bit status field. The fields defined are: bit 6 remotePacketLine - decimal 64 bit 7 aBitOk - decimal 128. A value of 0 indicates no bits are set." ::= { connEntry 28 } connLocalLine OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT connection-cfg, FIELD connLocalLine -- C-LOCATOR-FUNC conn-locator STATUS mandatory DESCRIPTION "Local Line Number. Valid only for AXIS" ::= { connEntry 29 } -- -- -- Real Time Counters Group -- -- -- packet Line Real Time Counters table has been deleted and replace by -- the TrunkLine Real Time Counters table beginning with -- StrataView Plus release ??? -- --PktLineRTCTable OBJECT-TYPE -- SYNTAX SEQUENCE OF PktLineRTCEntry -- ACCESS not-accessible -- STATUS mandatory -- DESCRIPTION "The table of Packet s Line statistics." -- ::= { realTimeCountersGroup 1 } -- -- circuit Line Real Time Counters table -- cirLineRTCTable OBJECT-TYPE SYNTAX SEQUENCE OF CirLineRTCEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table of Circuit Line statistics." ::= { realTimeCountersGroup 2 } cirLineRTCEntry OBJECT-TYPE SYNTAX CirLineRTCEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Circuit Line statistics table. Each row may be sparse." INDEX { cirLineRTCLineNumber } -- C-NEXT-FUNC cirLine-next ::= { cirLineRTCTable 1 } CirLineRTCEntry ::= SEQUENCE { -- -- All of the Counters in this table can be very time-expensive -- to retrieve, taking as much as 10 seconds each. -- Manger timeout values should be adjusted accordingly, and -- Get-Next walks through this portion of the table should be -- avoided. -- cirLineRTCLineNumber INTEGER, cirLineRTCBipolarViolations Counter, cirLineRTCFrameSlips Counter, cirLineRTCOutOfFrames Counter, cirLineRTCLossesOfSignal Counter, cirLineRTCFrameBitErrors Counter, cirLineRTCCrcErrors Counter, cirLineRTCOutOfMultiFrames Counter, cirLineRTCAllOnesInTimeslot16 Counter } cirLineRTCLineNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT cir-line-cfg, FIELD cirLineLineNumber -- C-LOCATOR-FUNC cirLine-locator STATUS mandatory DESCRIPTION "Circuit Line Line Number." ::= { cirLineRTCEntry 1 } cirLineRTCBipolarViolations OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC cirLineRTCBipolarViolations -- C-NEXT-FUNC cirLine-BipolarViolations-next -- C-PRE-GET-FUNC PreGet-cirLineRTCBipolarViolations STATUS mandatory DESCRIPTION "The number of bipolar violations which have occurred on the line. This statistic is valid for T1 circuits only." ::= { cirLineRTCEntry 4 } cirLineRTCFrameSlips OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC cirLineRTCFrameSlips -- C-NEXT-FUNC cirLine-FrameSlips-next -- C-PRE-GET-FUNC PreGet-cirLineRTCFrameSlips STATUS mandatory DESCRIPTION "The number of frame slips which have occurred on the receive side of the line. This statistic is valid for TXR lines only. CIP and CDP cards do not support this statistic." ::= { cirLineRTCEntry 5 } cirLineRTCOutOfFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC cirLineRTCOutOfFrames -- C-NEXT-FUNC cirLine-OutOfFrames-next -- C-PRE-GET-FUNC PreGet-cirLineRTCOutOfFrames STATUS mandatory DESCRIPTION "The number of 0 -> 1 transitions of the out of frame conditions as detected by the hardware." ::= { cirLineRTCEntry 6 } cirLineRTCLossesOfSignal OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC cirLineRTCLossesOfSignal -- C-NEXT-FUNC cirLine-LossesOfSignal-next -- C-PRE-GET-FUNC PreGet-cirLineRTCLossesOfSignal STATUS mandatory DESCRIPTION "The number of 0 -> 1 transitions of the loss of signal condition as detected by the hardware. This statistic is valid on CIP and CDP lines only. TXR lines do not support this statistic." ::= { cirLineRTCEntry 7 } cirLineRTCFrameBitErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC cirLineRTCFrameBitErrors -- C-NEXT-FUNC cirLine-FrameBitErrors-next -- C-PRE-GET-FUNC PreGet-cirLineRTCFrameBitErrors STATUS mandatory DESCRIPTION "The number of frame alignment signal errors which are detected on a line. This statistic is valid only on lines supported by CIP and CDP cards. TXR cards do not support this statistic." ::= { cirLineRTCEntry 8 } cirLineRTCCrcErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC cirLineRTCCrcErrors -- C-NEXT-FUNC cirLine-CrcErrors-next -- C-PRE-GET-FUNC PreGet-cirLineRTCCrcErrors STATUS mandatory DESCRIPTION "The number of CRC errors detected on the line. This statistic is valid on lines supported by CIP and CDP cards. TXR cards do no support this statistic." ::= { cirLineRTCEntry 9 } cirLineRTCOutOfMultiFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC cirLineRTCOutOfMultiFrames -- C-NEXT-FUNC cirLine-OutOfMultiFrames-next -- C-PRE-GET-FUNC PreGet-cirLineRTCOutOfMultiFrames STATUS mandatory DESCRIPTION "The number of 0 -> 1 transitions into out of multi-frame as detected by the hardware. This statistic is valid only on E1 lines. T1 lines do not support this statistic." ::= { cirLineRTCEntry 10 } cirLineRTCAllOnesInTimeslot16 OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC cirLineRTCAllOnesInTimeslot16 -- C-NEXT-FUNC cirLine-AllOnesInTimeslot16-next -- C-PRE-GET-FUNC PreGet-cirLineRTCAllOnesInTimeslot16 STATUS mandatory DESCRIPTION "The number of 0 -> 1 transitions of AIS-16. This statistic is valid only for CIP and CDP E1 format lines." ::= { cirLineRTCEntry 11 } -- -- Frame relay Real Time Counters table -- frpRTCTable OBJECT-TYPE SYNTAX SEQUENCE OF FrpRTCEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table of frame relay statistics." ::= { realTimeCountersGroup 3 } frpRTCEntry OBJECT-TYPE SYNTAX FrpRTCEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the frame relay statistics table. Each row may be sparse." INDEX { frpRTCSlot, frpRTCLine, frpRTCPort } -- C-NEXT-FUNC frp-next ::= { frpRTCTable 1 } FrpRTCEntry ::= SEQUENCE { -- -- All of the Counters in this table can be very time-expensive -- to retrieve, taking as much as 10 seconds each. -- Manger timeout values should be adjusted accordingly, and -- Get-Next walks through this portion of the table should be -- avoided. -- frpRTCSlot INTEGER, frpRTCPort INTEGER, frpRTCFramesRcvd Counter, frpRTCFramesXmitted Counter, frpRTCBytesRcvd Counter, frpRTCBytesXmitted Counter, frpRTCFramesXmittedWithFECN Counter, frpRTCFramesXmittedWithBECN Counter, frpRTCFramesRcvdCrcErrors Counter, frpRTCFramesRcvdInvalidFormat Counter, frpRTCFramesRcvdAlignmentErrors Counter, frpRTCFramesRcvdIllegalLen Counter, frpRTCDmaOverruns Counter, frpRTCLmiStatusEnquires Counter, frpRTCLmiStatusXmitRate Counter, frpRTCLmiStatusUpdateRate Counter, frpRTCLmiInvalidStatusEnquires Counter, frpRTCLmiLinkTimeoutErrors Counter, frpRTCLmiKeepaliveSequenceErrors Counter, frpRTCFramesRcvdUndefDlciErrors Counter, frpRTCXmitStatusEnquirey Counter, frpRTCRxStatusCounter Counter, frpRTCAsyncStatusCounter Counter, frpRTCBadSequenceNumberCount Counter, frpRTCTxProtocolTimeOutCount Counter, frpRTCCLLMFramesTx Counter, frpRTCCLLMBytesTx Counter, frpRTCCLLMFramesRx Counter, frpRTCCLLMBytesRx Counter, frpRTCCLLMFailures Counter, frpRTCRxDEFramesDiscarded Counter, frpRTCLine INTEGER } frpRTCSlot OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT frp-cfg, FIELD frpLocalSlot -- C-LOCATOR-FUNC frp-locator STATUS mandatory DESCRIPTION "Local Slot Number." ::= { frpRTCEntry 1 } frpRTCPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT frp-cfg, FIELD frpLocalPort -- C-LOCATOR-FUNC frp-locator STATUS mandatory DESCRIPTION "Local Port Number. These are numbered starting at 1." ::= { frpRTCEntry 2 } frpRTCFramesRcvd OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC frpRTCFramesRcvd -- C-NEXT-FUNC frp-FramesRcvd-next -- C-PRE-GET-FUNC PreGet-frpRTCFramesRcvd STATUS mandatory DESCRIPTION "The number of frames received by the FRP port." ::= { frpRTCEntry 4 } frpRTCFramesXmitted OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC frpRTCFramesXmitted -- C-NEXT-FUNC frp-FramesXmitted-next -- C-PRE-GET-FUNC PreGet-frpRTCFramesXmitted STATUS mandatory DESCRIPTION "The number of frames transmitted out the FRP port." ::= { frpRTCEntry 5 } frpRTCBytesRcvd OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC frpRTCBytesRcvd -- C-NEXT-FUNC frp-BytesRcvd-next -- C-PRE-GET-FUNC PreGet-frpRTCBytesRcvd STATUS mandatory DESCRIPTION "The number of frame bytes received from the FRP port." ::= { frpRTCEntry 6 } frpRTCBytesXmitted OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC frpRTCBytesXmitted -- C-NEXT-FUNC frp-BytesXmitted-next -- C-PRE-GET-FUNC PreGet-frpRTCBytesXmitted STATUS mandatory DESCRIPTION "The number of frame bytes transmitted out the FRP port." ::= { frpRTCEntry 7 } frpRTCFramesXmittedWithFECN OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC frpRTCFramesXmittedWithFECN -- C-NEXT-FUNC frp-FramesXmittedWithFECN-next -- C-PRE-GET-FUNC PreGet-frpRTCFramesXmittedWithFECN STATUS mandatory DESCRIPTION "The number of frames transmitted out the FRP port with the FECN bit set." ::= { frpRTCEntry 8 } frpRTCFramesXmittedWithBECN OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC frpRTCFramesXmittedWithBECN -- C-NEXT-FUNC frp-FramesXmittedWithBECN-next -- C-PRE-GET-FUNC PreGet-frpRTCFramesXmittedWithBECN STATUS mandatory DESCRIPTION "The number of frames transmitted out the FRP port with the BECN bit set." ::= { frpRTCEntry 9 } frpRTCFramesRcvdCrcErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC frpRTCFramesRcvdCrcErrors -- C-NEXT-FUNC frp-FramesRcvdCrcErrors-next -- C-PRE-GET-FUNC PreGet-frpRTCFramesRcvdCrcErrors STATUS mandatory DESCRIPTION "The number of CRC errors on received frames for the FRP port." ::= { frpRTCEntry 10 } frpRTCFramesRcvdInvalidFormat OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC frpRTCFramesRcvdInvalidFormat -- C-NEXT-FUNC frp-FramesRcvdInvalidFormat-next -- C-PRE-GET-FUNC PreGet-frpRTCFramesRcvdInvalidFormat STATUS mandatory DESCRIPTION "The number of frames received by the FRP port which contain incorrect EA bit settings (1 in the first byte and/or 0 in the second byte)." ::= { frpRTCEntry 11 } frpRTCFramesRcvdAlignmentErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC frpRTCFramesRcvdAlignmentErrors -- C-NEXT-FUNC frp-FramesRcvdAlignmentErrors-next -- C-PRE-GET-FUNC PreGet-frpRTCFramesRcvdAlignmentErrors STATUS mandatory DESCRIPTION "The number of bit alignment errors on received frames for the FRP port." ::= { frpRTCEntry 12 } frpRTCFramesRcvdIllegalLen OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC frpRTCFramesRcvdIllegalLen -- C-NEXT-FUNC frp-FramesRcvdIllegalLen-next -- C-PRE-GET-FUNC PreGet-frpRTCFramesRcvdIllegalLen STATUS mandatory DESCRIPTION "The number of frames received by the FRP port which exceed the maximum allowed frame length." ::= { frpRTCEntry 13 } frpRTCDmaOverruns OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC frpRTCDmaOverruns -- C-NEXT-FUNC frp-DmaOverruns-next -- C-PRE-GET-FUNC PreGet-frpRTCDmaOverruns STATUS mandatory DESCRIPTION "The number of DMA overruns on the FRP port." ::= { frpRTCEntry 14 } frpRTCLmiStatusEnquires OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC frpRTCLmiStatusEnquires -- C-NEXT-FUNC frp-LmiStatusEnquires-next -- C-PRE-GET-FUNC PreGet-frpRTCLmiStatusEnquires STATUS mandatory DESCRIPTION "The number of LMI status enquires received from the user device by the FRP port." ::= { frpRTCEntry 15 } frpRTCLmiStatusXmitRate OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC frpRTCLmiStatusXmitRate -- C-NEXT-FUNC frp-LmiStatusXmitRate-next -- C-PRE-GET-FUNC PreGet-frpRTCLmiStatusXmitRate STATUS mandatory DESCRIPTION "The number of LMI status messages transmitted to the user device from the FRP port per ??." ::= { frpRTCEntry 16 } frpRTCLmiStatusUpdateRate OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC frpRTCLmiStatusUpdateRate -- C-NEXT-FUNC frp-LmiStatusUpdateRate-next -- C-PRE-GET-FUNC PreGet-frpRTCLmiStatusUpdateRate STATUS mandatory DESCRIPTION "The number of LMI update messages transmitted to the user device from the FRP port per ??." ::= { frpRTCEntry 17 } frpRTCLmiInvalidStatusEnquires OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC frpRTCLmiInvalidStatusEnquires -- C-NEXT-FUNC frp-LmiInvalidStatusEnquires-next -- C-PRE-GET-FUNC PreGet-frpRTCLmiInvalidStatusEnquires STATUS mandatory DESCRIPTION "The number of invalid LMI status enquires received from the user device by the FRP port." ::= { frpRTCEntry 18 } frpRTCLmiLinkTimeoutErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC frpRTCLmiLinkTimeoutErrors -- C-NEXT-FUNC frp-LmiLinkTimeoutErrors-next -- C-PRE-GET-FUNC PreGet-frpRTCLmiLinkTimeoutErrors STATUS mandatory DESCRIPTION "The number of LMI link timeout errors." ::= { frpRTCEntry 19 } frpRTCLmiKeepaliveSequenceErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC frpRTCLmiKeepaliveSequenceErrors -- C-NEXT-FUNC frp-LmiKeepaliveSequenceErrors-next -- C-PRE-GET-FUNC PreGet-frpRTCLmiKeepaliveSequenceErrors STATUS mandatory DESCRIPTION "The number of LMI keepalive sequence number errors." ::= { frpRTCEntry 20 } frpRTCFramesRcvdUndefDlciErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC frpRTCFramesRcvdUndefDlciErrors -- C-NEXT-FUNC frp-FramesRcvdUndefDlciErrors-next -- C-PRE-GET-FUNC PreGet-frpRTCFramesRcvdUndefDlciErrors STATUS mandatory DESCRIPTION "The number of frames received by the FRP port which contain undefined DLCIs." ::= { frpRTCEntry 21 } frpRTCXmitStatusEnquirey OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC frpRTCXmitStatusEnquirey -- C-NEXT-FUNC frp-XmitStatusEnquirey-next -- C-PRE-GET-FUNC PreGet-frpRTCXmitStatusEnquirey STATUS mandatory DESCRIPTION "Transmit Status Enquirey." ::= { frpRTCEntry 22 } frpRTCRxStatusCounter OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC frpRTCRxStatusCounter -- C-NEXT-FUNC frp-RxStatusCounter-next -- C-PRE-GET-FUNC PreGet-frpRTCRxStatusCounter STATUS mandatory DESCRIPTION "Received Status counter." ::= { frpRTCEntry 23 } frpRTCAsyncStatusCounter OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC frpRTCAsyncStatusCounter -- C-NEXT-FUNC frp-AsyncStatusCounter-next -- C-PRE-GET-FUNC PreGet-frpRTCAsyncStatusCounter STATUS mandatory DESCRIPTION "Asynchronous Status Counter." ::= { frpRTCEntry 24 } frpRTCBadSequenceNumberCount OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC frpRTCBadSequenceNumberCount -- C-NEXT-FUNC frp-BadSequenceNumberCount-next -- C-PRE-GET-FUNC PreGet-frpRTCBadSequenceNumberCount STATUS mandatory DESCRIPTION "Invalid Sequence number count." ::= { frpRTCEntry 25 } frpRTCTxProtocolTimeOutCount OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC frpRTCTxProtocolTimeOutCount -- C-NEXT-FUNC frp-TxProtocolTimeOutCount-next -- C-PRE-GET-FUNC PreGet-frpRTCTxProtocolTimeOutCount STATUS mandatory DESCRIPTION "Transmit Protocol timeout count." ::= { frpRTCEntry 26 } frpRTCCLLMFramesTx OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC frpRTCCLLMFramesTx -- C-NEXT-FUNC frp-CLLMFramesTx-next -- C-PRE-GET-FUNC PreGet-frpRTCCLLMFramesTx STATUS mandatory DESCRIPTION "CLLM message frames transmited." ::= { frpRTCEntry 27 } frpRTCCLLMBytesTx OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC frpRTCCLLMBytesTx -- C-NEXT-FUNC frp-CLLMBytesTx-next -- C-PRE-GET-FUNC PreGet-frpRTCCLLMBytesTx STATUS mandatory DESCRIPTION "CLLM message bytes transmitted." ::= { frpRTCEntry 28 } frpRTCCLLMFramesRx OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC frpRTCCLLMFramesRx -- C-NEXT-FUNC frp-CLLMFramesRx-next -- C-PRE-GET-FUNC PreGet-frpRTCCLLMFramesRx STATUS mandatory DESCRIPTION "CLLM Frames received." ::= { frpRTCEntry 29 } frpRTCCLLMBytesRx OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC frpRTCCLLMBytesRx -- C-NEXT-FUNC frp-CLLMBytesRx-next -- C-PRE-GET-FUNC PreGet-frpRTCCLLMBytesRx STATUS mandatory DESCRIPTION "CLLM bytes received." ::= { frpRTCEntry 30 } frpRTCCLLMFailures OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC frpRTCCLLMFailures -- C-NEXT-FUNC frp-CLLMFailures-next -- C-PRE-GET-FUNC PreGet-frpRTCCLLMFailures STATUS mandatory DESCRIPTION "CLLM failures." ::= { frpRTCEntry 31 } frpRTCRxDEFramesDiscarded OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC frpRTCRxDEFramesDiscarded -- C-NEXT-FUNC frp-RxDEFramesDiscarded-next -- C-PRE-GET-FUNC PreGet-frpRTCRxDEFramesDiscarded STATUS mandatory DESCRIPTION "The number of frames with the DE bit set which have been dropped by the frame relay port. IPX software versions earlier than IPX 6.1 will report a count of zero." ::= { frpRTCEntry 32} frpRTCLine OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT frp-cfg, FIELD frpLocalLine -- C-LOCATOR-FUNC frp-locator STATUS mandatory DESCRIPTION "Local Slot Number." ::= { frpRTCEntry 33 } -- -- Connection Real Time Counters Table -- connRTCTable OBJECT-TYPE SYNTAX SEQUENCE OF ConnRTCEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table of Connection statistics." ::= { realTimeCountersGroup 4 } connRTCEntry OBJECT-TYPE SYNTAX ConnRTCEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Connection statistics table." INDEX { connRTCSlot, connRTCLine, connRTCChannel, connRTCDLCI } -- C-NEXT-FUNC conn-next ::= { connRTCTable 1 } ConnRTCEntry ::= SEQUENCE { -- -- All of the Counters in this table can be very time-expensive -- to retrieve, taking as much as 10 seconds each. -- Manger timeout values should be adjusted accordingly, and -- Get-Next walks through this portion of the table should be -- avoided. -- connRTCSlot INTEGER, connRTCChannel INTEGER, connRTCDLCI INTEGER, connRTCRcvdFrames Counter, connRTCRcvdFramesDiscarded Counter, connRTCXmitFrames Counter, connRTCXmitFramesDiscarded Counter, connRTCRcvdPkts Counter, connRTCRcvdPktsDiscarded Counter, connRTCXmitPkts Counter, connRTCXmitPktsProjected Counter, connRTCXmitPktsSupervisory Counter, connRTCRcvdBytes Counter, connRTCRcvdBytesDiscarded Counter, connRTCXmitBytes Counter, connRTCXmitBytesDiscarded Counter, connRTCSecondsV25ModemOn Counter, connRTCSecondsDsiEnabled Counter, connRTCSecondsOffHook Counter, connRTCSecondsInService Counter, connRTCXmitFramesWithFECN Counter, connRTCXmitFramesWithBECN Counter, connRTCRxSupervisoryPkts Counter, connRTCCongestedMinuites Counter, connRTCFramesRxWithDE Counter, connRTCFramesTxWithDE Counter, connRTCFramesDiscardedWithDE Counter, connRTCBytesRxWithDE Counter, connRTCFramesRxExcessCir Counter, connRTCBytesRxExcessCir Counter, connRTCFramesTxExcessCir Counter, connRTCBytesTxExcessCir Counter, connRTCLine INTEGER } connRTCSlot OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT connection-cfg, FIELD connLocalSlot -- C-LOCATOR-FUNC conn-locator STATUS mandatory DESCRIPTION "Local Slot Number." ::= { connRTCEntry 1 } connRTCChannel OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT connection-cfg, FIELD connLocalChannel -- C-LOCATOR-FUNC conn-locator STATUS mandatory DESCRIPTION "Local Channel Number. These are numbered starting at 1." ::= { connRTCEntry 2 } connRTCDLCI OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT connection-cfg, FIELD connLocalDLCI -- C-LOCATOR-FUNC conn-locator STATUS mandatory DESCRIPTION "Local DLCI Number." ::= { connRTCEntry 3 } connRTCRcvdFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC connRTCRcvdFrames -- C-NEXT-FUNC conn-RcvdFrames-next -- C-PRE-GET-FUNC PreGet-connRTCRcvdFrames STATUS mandatory DESCRIPTION "The number of frames received from the FRP port associated with the connection. This statistic is valid for Frame Relay Connections only." ::= { connRTCEntry 4 } connRTCRcvdFramesDiscarded OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC connRTCRcvdFramesDiscarded -- C-NEXT-FUNC conn-RcvdFramesDiscarded-next -- C-PRE-GET-FUNC PreGet-connRTCRcvdFramesDiscarded STATUS mandatory DESCRIPTION "The number of frames received from the FRP port which are associated with the connection, but were discarded before being transmitted onto the Muxbus due to the age of the frame in the IPX system or the lack of buffer space. This statistic is valid for Frame Relay Connections only." ::= { connRTCEntry 5 } connRTCXmitFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC connRTCXmitFrames -- C-NEXT-FUNC conn-XmitFrames-next -- C-PRE-GET-FUNC PreGet-connRTCXmitFrames STATUS mandatory DESCRIPTION "The number of frames transmitted out the FRP port which were received from the other endpoint of the connection. This statistic is valid for Frame Relay connections only." ::= { connRTCEntry 6 } connRTCXmitFramesDiscarded OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC connRTCXmitFramesDiscarded -- C-NEXT-FUNC conn-XmitFramesDiscarded-next -- C-PRE-GET-FUNC PreGet-connRTCXmitFramesDiscarded STATUS mandatory DESCRIPTION "The number of frames to be transmitted out the FRP port which were received from the other endpoint of the connection, but were discarded due to the age of the frame in the IPX system, a CRC error, or lack of buffer space. This statistic is valid for Frame Relay Connections only." ::= { connRTCEntry 7 } connRTCRcvdPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC connRTCRcvdPkts -- C-NEXT-FUNC conn-RcvdPkts-next -- C-PRE-GET-FUNC PreGet-connRTCRcvdPkts STATUS mandatory DESCRIPTION "The number of packets received from the Muxbus by the FRP port associated with the connection endpoint. This statistic is valid for Frame Relay Connections only." ::= { connRTCEntry 8 } connRTCRcvdPktsDiscarded OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC connRTCRcvdPktsDiscarded -- C-NEXT-FUNC conn-RcvdPktsDiscarded-next -- C-PRE-GET-FUNC PreGet-connRTCRcvdPktsDiscarded STATUS mandatory DESCRIPTION "The number of packets received from the Muxbus at the FRP port associated with the connection endpoint, but were discarded before being ssembled into frames and transmitted on the FRP port. This statistic is valid for Frame Relay Connections only." ::= { connRTCEntry 9 } connRTCXmitPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC connRTCXmitPkts -- C-NEXT-FUNC conn-XmitPkts-next -- C-PRE-GET-FUNC PreGet-connRTCXmitPkts STATUS mandatory DESCRIPTION "The number of packets transmitted from one connection endpoint onto the Muxbus towards the other connection endpoint. This statistic is valid for all types of inter-node connections, and for CDP Data, FRP, LDP and SDP terminated DAX connections." ::= { connRTCEntry 10 } connRTCXmitPktsProjected OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC connRTCXmitPktsProjected -- C-NEXT-FUNC conn-XmitPktsProjected-next -- C-PRE-GET-FUNC PreGet-connRTCXmitPktsProjected STATUS mandatory DESCRIPTION "The estimated number of packets which would be used if DSI or DFM were enabled for the connection. This statistic is valid for inter-node voice connections and with all types of data connections. It is not valid for DAX voice connections or Frame Relay connections." ::= { connRTCEntry 11 } connRTCXmitPktsSupervisory OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC connRTCXmitPktsSupervisory -- C-NEXT-FUNC conn-XmitPktsSupervisory-next -- C-PRE-GET-FUNC PreGet-connRTCXmitPktsSupervisory STATUS mandatory DESCRIPTION "The number of supervisory packets transmitted from one connection endpoint to another. Supervisory packets reflect signaling bit transitions for voice connections, and EIA lead transitions for data channels. This statistic is valid on all inter-node 'a', 'c', and 'v' voice connections, all inter-node data connections, all 'd' type voice connection endpoints which are supported by CIP or CDP cards, and all DAX data connections. This statistic is not valid for Frame Relay connections." ::= { connRTCEntry 12 } connRTCRcvdBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC connRTCRcvdBytes -- C-NEXT-FUNC conn-RcvdBytes-next -- C-PRE-GET-FUNC PreGet-connRTCRcvdBytes STATUS mandatory DESCRIPTION "The number of frame bytes received from the FRP port associated with the connection endpoint. This statistic is valid for Frame Relay connections only." ::= { connRTCEntry 13 } connRTCRcvdBytesDiscarded OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC connRTCRcvdBytesDiscarded -- C-NEXT-FUNC conn-RcvdBytesDiscarded-next -- C-PRE-GET-FUNC PreGet-connRTCRcvdBytesDiscarded STATUS mandatory DESCRIPTION "The number of frame bytes received from the FRP port associated with the connection endpoint, but were discarded due to the age of the frame in the IPX system or the lack of buffer space before being transmitted onto the Muxbus. This statistic is valid for Frame Relay connections only." ::= { connRTCEntry 14 } connRTCXmitBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC connRTCXmitBytes -- C-NEXT-FUNC conn-XmitBytes-next -- C-PRE-GET-FUNC PreGet-connRTCXmitBytes STATUS mandatory DESCRIPTION "The number of frame bytes to be received from the Muxbus from the remote end of the connection, which were actually transmitted out the FRP port as frames. This statistic is valid for Frame Relay connections only." ::= { connRTCEntry 15 } connRTCXmitBytesDiscarded OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC connRTCXmitBytesDiscarded -- C-NEXT-FUNC conn-XmitBytesDiscarded-next -- C-PRE-GET-FUNC PreGet-connRTCXmitBytesDiscarded STATUS mandatory DESCRIPTION "The number of frame bytes to be received from the Muxbus from the remote end of the connection, but were discarded due to the age of the frame in the IPX system, a CRC error, or lack of buffer space. This statistic is valid for Frame Relay connections only." ::= { connRTCEntry 16 } connRTCSecondsV25ModemOn OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC connRTCSecondsV25ModemOn -- C-NEXT-FUNC conn-SecondsV25ModemOn-next -- C-PRE-GET-FUNC PreGet-connRTCSecondsV25ModemOn STATUS mandatory DESCRIPTION "The number of seconds the V.25 modem has been detected and a connection upgraded from ADPCM to PCM. The status of the V.25 modem detect is checked every 3 seconds, so the granularity of the data which makes up this statistic is 3 seconds. This statistic is valid for inter- node type 'a', 'c' and 'v' voice connections only." ::= { connRTCEntry 17 } connRTCSecondsDsiEnabled OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC connRTCSecondsDsiEnabled -- C-NEXT-FUNC conn-SecondsDsiEnabled-next -- C-PRE-GET-FUNC PreGet-connRTCSecondsDsiEnabled STATUS mandatory DESCRIPTION "The number of seconds that a connection has been performing Digital Speech Interpolation (DSI). The status of DSI is checked every 3 seconds, so the granularity of the data which makes up this statistic is 3 seconds. This statistic is valid for inter-node type 'c' and 'v' voice connections only." ::= { connRTCEntry 18 } connRTCSecondsOffHook OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC connRTCSecondsOffHook -- C-NEXT-FUNC conn-SecondsOffHook-next -- C-PRE-GET-FUNC PreGet-connRTCSecondsOffHook STATUS mandatory DESCRIPTION "The number of seconds that a voice connection has been off-hook. The on-hook state is determined by the signaling bits, as defined by the 'cnfchtp' command. A connection which is not on-hook is treated as off-hook for this statistic. The status of the off-hook condition is checked every 3 seconds, so the granularity of the data which makes up this statistic is 3 seconds. This statistic is valid for all 'a', 'c' and 'v' voice connections, and for 'd' type voice connection endpoints supported by CIP or CDP cards." ::= { connRTCEntry 19 } connRTCSecondsInService OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC connRTCSecondsInService -- C-NEXT-FUNC conn-SecondsInService-next -- C-PRE-GET-FUNC PreGet-connRTCSecondsInService STATUS mandatory DESCRIPTION "The number of seconds that a connection has been in service. A conection is considered to be in service if its end points are not in alarm, that cards required to support the connection are present, and the connection is routed." ::= { connRTCEntry 20 } connRTCXmitFramesWithFECN OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC connRTCXmitFramesWithFECN -- C-NEXT-FUNC conn-XmitFramesWithFECN-next -- C-PRE-GET-FUNC PreGet-connRTCXmitFramesWithFECN STATUS mandatory DESCRIPTION "The number of frames transmitted out the FRP port with the FECN bit set. This statistic is valid for Frame Relay connections only." ::= { connRTCEntry 21 } connRTCXmitFramesWithBECN OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC connRTCXmitFramesWithBECN -- C-NEXT-FUNC conn-XmitFramesWithBECN-next -- C-PRE-GET-FUNC PreGet-connRTCXmitFramesWithBECN STATUS mandatory DESCRIPTION "The number of frames transmitted out the FRP port with the BECN bit set. This statistic is valid for Frame Relay connections only." ::= { connRTCEntry 22 } connRTCRxSupervisoryPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC connRTCRxSupervisoryPkts -- C-NEXT-FUNC conn-RxSupervisoryPkts-next -- C-PRE-GET-FUNC PreGet-connRTCRxSupervisoryPkts STATUS mandatory DESCRIPTION "The number of of supervisory packets received." ::= { connRTCEntry 23 } connRTCCongestedMinuites OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC connRTCCongestedMinuites -- C-NEXT-FUNC conn-CongestedMinuites-next -- C-PRE-GET-FUNC PreGet-connRTCCongestedMinuites STATUS mandatory DESCRIPTION "The number of minuites in which 50%or more frames are tagged FECN by the FRP." ::= { connRTCEntry 24 } connRTCFramesRxWithDE OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC connRTCFramesRxWithDE -- C-NEXT-FUNC conn-FramesRxWithDE-next -- C-PRE-GET-FUNC PreGet-connRTCFramesRxWithDE STATUS mandatory DESCRIPTION "The number of frames received from the FRP with the DE bit set." ::= { connRTCEntry 25 } connRTCFramesTxWithDE OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC connRTCFramesTxWithDE -- C-NEXT-FUNC conn-FramesTxWithDE-next -- C-PRE-GET-FUNC PreGet-connRTCFramesTxWithDE STATUS mandatory DESCRIPTION "The number of frames transmitted from the FRP with the DE bit set. " ::= { connRTCEntry 26 } connRTCFramesDiscardedWithDE OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC connRTCFramesDiscardedWithDE -- C-NEXT-FUNC conn-FramesDiscardedWithDE-next -- C-PRE-GET-FUNC PreGet-connRTCFramesDiscardedWithDE STATUS mandatory DESCRIPTION "The number of frames received from the local frame relay port with their DE bit set which are discarded before being transmitted onto the Muxbus." ::= { connRTCEntry 27 } connRTCBytesRxWithDE OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC connRTCBytesRxWithDE -- C-NEXT-FUNC conn-BytesRxWithDE-next -- C-PRE-GET-FUNC PreGet-connRTCBytesRxWithDE STATUS mandatory DESCRIPTION "The number of bytes received from the FRP for frames with the DE bit set." ::= { connRTCEntry 28 } connRTCFramesRxExcessCir OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC connRTCFramesRxExcessCir -- C-NEXT-FUNC conn-FramesRxExcessCir-next -- C-PRE-GET-FUNC PreGet-connRTCFramesRxExcessCir STATUS mandatory DESCRIPTION "The number of frames received in excess of CIR." ::= { connRTCEntry 29 } connRTCBytesRxExcessCir OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC connRTCBytesRxExcessCir -- C-NEXT-FUNC conn-BytesRxExcessCir-next -- C-PRE-GET-FUNC PreGet-connRTCBytesRxExcessCir STATUS mandatory DESCRIPTION "The number of frames received in excess of CIR." ::= { connRTCEntry 30 } connRTCFramesTxExcessCir OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC connRTCFramesTxExcessCir -- C-NEXT-FUNC conn-FramesTxExcessCir-next -- C-PRE-GET-FUNC PreGet-connRTCFramesTxExcessCir STATUS mandatory DESCRIPTION "The number of frames transmitted in excess of CIR." ::= { connRTCEntry 31 } connRTCBytesTxExcessCir OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC connRTCBytesTxExcessCir -- C-NEXT-FUNC conn-BytesTxExcessCir-next -- C-PRE-GET-FUNC PreGet-connRTCBytesTxExcessCir STATUS mandatory DESCRIPTION "The number of frames transmitted in excess of CIR." ::= { connRTCEntry 32 } connRTCLine OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT connection-cfg, FIELD connLocalLine -- C-LOCATOR-FUNC conn-locator STATUS mandatory DESCRIPTION "Line Number, for IPX it is always 0." ::= { connRTCEntry 33 } -- -- Trunk Real Time Counter Table -- valid only for SV Plus release ???? trunkRTCTable OBJECT-TYPE SYNTAX SEQUENCE OF TrunkRTCEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table of Trunk Line statistics." ::= { realTimeCountersGroup 5 } trunkRTCEntry OBJECT-TYPE SYNTAX TrunkRTCEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Trunk Line statistics table. Each row may be sparse." INDEX { trunkRTCLocalSlot, trunkRTCLocalPort } -- C-NEXT-FUNC trunk-next ::= { trunkRTCTable 1 } TrunkRTCEntry ::= SEQUENCE { -- -- All of the Counters in this table can be very time-expensive -- to retrieve, taking as much as 10 seconds each. -- Manger timeout values should be adjusted accordingly, and -- Get-Next walks through this portion of the table should be -- avoided. -- trunkRTCLocalSlot INTEGER, trunkRTCLocalPort INTEGER, trunkRTCBipolarViolations Counter, trunkRTCFrameSlips Counter, trunkRTCOutOfFrames Counter, trunkRTCLossOfSignal Counter, trunkRTCFrameBitErrors Counter, trunkRTCCrcErrors Counter, trunkRTCPktOutOfFrames Counter, trunkRTCPktCrcErrors Counter, trunkRTCBadClockErrors Counter, trunkRTCVoicePktsDropped Counter, trunkRTCTimeStampedPktsDropped Counter, trunkRTCNonTimeStampedPktsDropped Counter, trunkRTCHighPriorityPktsDropped Counter, trunkRTCBurstyDataPktsDropped Counter, trunkRTCMulticastPktsDropped Counter, trunkRTCVoicePktsXmitted Counter, trunkRTCTimeStampedPktsXmitted Counter, trunkRTCNonTimeStampedPktsXmitted Counter, trunkRTCHighPriorityPktsXmitted Counter, trunkRTCBurstyDataPktsXmitted Counter, trunkRTCMulticastPktsXmitted Counter, trunkRTCPktsXmitted Counter, trunkRTCTxBurstyDataAClpPktsDropped Counter, trunkRTCTxBurstyDataBClpPktsDropped Counter, trunkRTCBurstyDataAEfcnPktsTx2Line Counter, trunkRTCBurstyDataBEfcnPktsTx2Line Counter, trunkRTCBurstyDataAClpPktsTx2Line Counter, trunkRTCBurstyDataBClpPktsTx2Line Counter, trunkRTCAtmCellHeaderHecErrors Counter, trunkRTCTxVoiceCellsDropped Counter, trunkRTCTxTimeStampCellsDropped Counter, trunkRTCTxNonTStampCellsDropped Counter, trunkRTCTxHighPriorityCellsDropped Counter, trunkRTCTxBurstyDataACellsDropped Counter, trunkRTCTxBurstyDataBCellsDropped Counter, trunkRTCVoiceCellsTx2Line Counter, trunkRTCTimeStampCellsTx2Line Counter, trunkRTCNonTimeStampCellsTx2Line Counter, trunkRTCHighPriorityCellsTx2Line Counter, trunkRTCBurstyDataACellsTx2Line Counter, trunkRTCBurstyDataBCellsTx2Line Counter, trunkRTCTotalCellsTx2Line Counter, trunkRTCTxBurstyDataAClpCellsDropped Counter, trunkRTCTxBurstyDataBClpCellsDropped Counter, trunkRTCBurstyDataAEfcnCellsTx2Line Counter, trunkRTCBurstyDataBEfcnCellsTx2Line Counter, trunkRTCPlcpOutOfFrames Counter } trunkRTCLocalSlot OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT trunk-cfg, FIELD trunkLocalSlot -- C-LOCATOR-FUNC trunk-locator STATUS mandatory DESCRIPTION "Local Slot Number. These are numbered starting at 1" ::= { trunkRTCEntry 1 } trunkRTCLocalPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT trunk-cfg, FIELD trunkLocalPort -- C-LOCATOR-FUNC trunk-locator STATUS mandatory DESCRIPTION "Local Port Number. These are numbered starting at 1." ::= { trunkRTCEntry 2 } trunkRTCBipolarViolations OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC trunkRTCBipolarViolations -- C-NEXT-FUNC trunk-BipolarViolations-next -- C-PRE-GET-FUNC PreGet-trunkRTCBipolarViolations STATUS mandatory DESCRIPTION "The signal level for a '1' bit should alternate between a positive and a negative signal. If two positive or two negative signals are received in a row, a bipolar violation has occurred." ::= { trunkRTCEntry 4 } trunkRTCFrameSlips OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC trunkRTCFrameSlips -- C-NEXT-FUNC trunk-FrameSlips-next -- C-PRE-GET-FUNC PreGet-trunkRTCFrameSlips STATUS mandatory DESCRIPTION "The number of frame slips which have occurred on the receive side of the line. This statistic is valid for TXR lines only. NTC cards do not support this statistic." ::= { trunkRTCEntry 5 } trunkRTCOutOfFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC trunkRTCOutOfFrames -- C-NEXT-FUNC trunk-OutOfFrames-next -- C-PRE-GET-FUNC PreGet-trunkRTCOutOfFrames STATUS mandatory DESCRIPTION "The number of 0 -> 1 transitions of the out of frame condition as detected by the hardware. This statistic is valid for T1 and E1 lines only." ::= { trunkRTCEntry 6 } trunkRTCLossOfSignal OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC trunkRTCLossOfSignal -- C-NEXT-FUNC trunk-LossOfSignal-next -- C-PRE-GET-FUNC PreGet-trunkRTCLossOfSignal STATUS mandatory DESCRIPTION "The number of 0 -> 1 transitions of the loss of signal condition as detected by the hardware. This statistic is valid for NTC lines only." ::= { trunkRTCEntry 7 } trunkRTCFrameBitErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC trunkRTCFrameBitErrors -- C-NEXT-FUNC trunk-FrameBitErrors-next -- C-PRE-GET-FUNC PreGet-trunkRTCFrameBitErrors STATUS mandatory DESCRIPTION "The number of frame alignment signal errors which have been detected on this line. This statistic is valid only on lines supported by NTC cards. TXR and Sub-rate lines do not support this statistic. This statistic is also not supported by NTC-T1 in ESF framing mode." ::= { trunkRTCEntry 8 } trunkRTCCrcErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC trunkRTCCrcErrors -- C-NEXT-FUNC trunk-CrcErrors-next -- C-PRE-GET-FUNC PreGet-trunkRTCCrcErrors STATUS mandatory DESCRIPTION "The number of CRC errors detected on the line. This statistic is valid only on lines supported by NTC cards. TXR cards and Sub-rate lines do not support this statistic. This statistic is also not supported by NTC-T1 in D4 framing mode." ::= { trunkRTCEntry 9 } trunkRTCPktOutOfFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC trunkRTCPktOutOfFrames -- C-NEXT-FUNC trunk-PktOutOfFrames-next -- C-PRE-GET-FUNC PreGet-trunkRTCPktOutOfFrames STATUS mandatory DESCRIPTION "The number of packets out of frames on this line. This statistic is only valid on lines supported by NTC cards. TXR cards do not support this statistic." ::= { trunkRTCEntry 10 } trunkRTCPktCrcErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC trunkRTCPktCrcErrors -- C-NEXT-FUNC trunk-PktCrcErrors-next -- C-PRE-GET-FUNC PreGet-trunkRTCPktCrcErrors STATUS mandatory DESCRIPTION "The number of packets received with detected CRC errors in the packet headers." ::= { trunkRTCEntry 11 } trunkRTCBadClockErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC trunkRTCBadClockErrors -- C-NEXT-FUNC trunk-BadClockErrors-next -- C-PRE-GET-FUNC PreGet-trunkRTCBadClockErrors STATUS mandatory DESCRIPTION "The number of 0 -> 1 transitions of the loss of clock condition as detected by the hardware. This statistic is valid on NTC Sub-rate lines only. T1 and E1 lines do not support this statistic." ::= { trunkRTCEntry 12 } trunkRTCVoicePktsDropped OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC trunkRTCVoicePktsDropped -- C-NEXT-FUNC trunk-FrameSlips-next -- C-PRE-GET-FUNC PreGet-trunkRTCVoicePktsDropped STATUS mandatory DESCRIPTION "The number of voice packets dropped on a line." ::= { trunkRTCEntry 13 } trunkRTCTimeStampedPktsDropped OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC trunkRTCTimeStampedPktsDropped -- C-NEXT-FUNC trunk-TimeStampedPktsDropped-next -- C-PRE-GET-FUNC PreGet-trunkRTCTimeStampedPktsDropped STATUS mandatory DESCRIPTION "The number of time stamped data packets dropped on the line." ::= { trunkRTCEntry 14 } trunkRTCNonTimeStampedPktsDropped OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC trunkRTCNonTimeStampedPktsDropped -- C-NEXT-FUNC trunk-NonTimeStampedPktsDropped-next -- C-PRE-GET-FUNC PreGet-trunkRTCNonTimeStampedPktsDropped STATUS mandatory DESCRIPTION "The number of non-time stamped data packets dropped on the line." ::= { trunkRTCEntry 15 } trunkRTCHighPriorityPktsDropped OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC trunkRTCHighPriorityPktsDropped -- C-NEXT-FUNC trunk-HighPriorityPktsDropped-next -- C-PRE-GET-FUNC PreGet-trunkRTCHighPriorityPktsDropped STATUS mandatory DESCRIPTION "The number of high priority (PCC) packets dropped on the line." ::= { trunkRTCEntry 16 } trunkRTCBurstyDataPktsDropped OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC trunkRTCBurstyDataPktsDropped -- C-NEXT-FUNC trunk-BurstyDataPktsDropped-next -- C-PRE-GET-FUNC PreGet-trunkRTCBurstyDataPktsDropped STATUS mandatory DESCRIPTION "The number of bursty data packets dropped on the line." ::= { trunkRTCEntry 17 } trunkRTCMulticastPktsDropped OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC trunkRTCMulticastPktsDropped -- C-NEXT-FUNC trunk-MulticastPktsDropped-next -- C-PRE-GET-FUNC PreGet-trunkRTCMulticastPktsDropped STATUS mandatory DESCRIPTION "The number of Multicast packets dropped on the line." ::= { trunkRTCEntry 18 } trunkRTCVoicePktsXmitted OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC trunkRTCVoicePktsXmitted -- C-NEXT-FUNC trunk-VoicePktsXmitted-next -- C-PRE-GET-FUNC PreGet-trunkRTCVoicePktsXmitted STATUS mandatory DESCRIPTION "The number of voice packets transmitted onto the line." ::= { trunkRTCEntry 19 } trunkRTCTimeStampedPktsXmitted OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC trunkRTCTimeStampedPktsXmitted -- C-NEXT-FUNC trunk-TimeStampedPktsXmitted-next -- C-PRE-GET-FUNC PreGet-trunkRTCTimeStampedPktsXmitted STATUS mandatory DESCRIPTION "The number of time stamped packets transmitted onto the line." ::= { trunkRTCEntry 20 } trunkRTCNonTimeStampedPktsXmitted OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC trunkRTCNonTimeStampedPktsXmitted -- C-NEXT-FUNC trunk-NonTimeStampedPktsXmitted-next -- C-PRE-GET-FUNC PreGet-trunkRTCNonTimeStampedPktsXmitted STATUS mandatory DESCRIPTION "The number of non-time stamped packets transmitted onto the line." ::= { trunkRTCEntry 21 } trunkRTCHighPriorityPktsXmitted OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC trunkRTCHighPriorityPktsXmitted -- C-NEXT-FUNC trunk-HighPriorityPktsXmitted-next -- C-PRE-GET-FUNC PreGet-trunkRTCHighPriorityPktsXmitted STATUS mandatory DESCRIPTION "The number of high priority packets transmitted onto the line." ::= { trunkRTCEntry 22 } trunkRTCBurstyDataPktsXmitted OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC trunkRTCBurstyDataPktsXmitted -- C-NEXT-FUNC trunk-BurstyDataPktsXmitted-next -- C-PRE-GET-FUNC PreGet-trunkRTCBurstyDataPktsXmitted STATUS mandatory DESCRIPTION "The number of bursty data packets transmitted onto the line." ::= { trunkRTCEntry 23 } trunkRTCMulticastPktsXmitted OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC trunkRTCMulticastPktsXmitted -- C-NEXT-FUNC trunk-MulticastPktsXmitted-next -- C-PRE-GET-FUNC PreGet-trunkRTCMulticastPktsXmitted STATUS mandatory DESCRIPTION "The number of Multicast packets transmitted onto the line." ::= { trunkRTCEntry 24 } trunkRTCPktsXmitted OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC trunkRTCPktsXmitted -- C-NEXT-FUNC trunk-PktsXmitted-next -- C-PRE-GET-FUNC PreGet-trunkRTCPktsXmitted STATUS mandatory DESCRIPTION "The total number of packets transmitted onto the line." ::= { trunkRTCEntry 25 } trunkRTCTxBurstyDataAClpPktsDropped OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC trunkRTCTxBurstyDataAClpPktsDropped -- C-NEXT-FUNC trunk-TxBurstyDataAClpPktsDropped-next -- C-PRE-GET-FUNC PreGet-trunkRTCTxBurstyDataAClpPktsDropped STATUS mandatory DESCRIPTION "The number of packets with the CLP bit set that are dropped from the bursty data A queue." ::= { trunkRTCEntry 26 } trunkRTCTxBurstyDataBClpPktsDropped OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC trunkRTCTxBurstyDataBClpPktsDropped -- C-NEXT-FUNC trunk-TxBurstyDataBClpPktsDropped-next -- C-PRE-GET-FUNC PreGet-trunkRTCTxBurstyDataBClpPktsDropped STATUS mandatory DESCRIPTION "The number of packets with the CLP bit set that are dropped from the bursty data B queue." ::= { trunkRTCEntry 27 } trunkRTCBurstyDataAEfcnPktsTx2Line OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC trunkRTCBurstyDataAEfcnPktsTx2Line -- C-NEXT-FUNC trunk-BurstyDataAEfcnPktsTx2Line-next -- C-PRE-GET-FUNC PreGet-trunkRTCBurstyDataAEfcnPktsTx2Line STATUS mandatory DESCRIPTION "The number of packets with the EFCN bit set which have been transmitted onto the line from the bursty data A queue." ::= { trunkRTCEntry 28 } trunkRTCBurstyDataBEfcnPktsTx2Line OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC trunkRTCBurstyDataBEfcnPktsTx2Line -- C-NEXT-FUNC trunk-BurstyDataBEfcnPktsTx2Line-next -- C-PRE-GET-FUNC PreGet-trunkRTCBurstyDataBEfcnPktsTx2Line STATUS mandatory DESCRIPTION "The number of packets with the EFCN bit set which have been transmitted onto the line from the bursty data B queue." ::= { trunkRTCEntry 29 } trunkRTCBurstyDataAClpPktsTx2Line OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC trunkRTCBurstyDataAClpPktsTx2Line -- C-NEXT-FUNC trunk-BurstyDataAClpPktsTx2Line-next -- C-PRE-GET-FUNC PreGet-trunkRTCBurstyDataAClpPktsTx2Line STATUS mandatory DESCRIPTION "The number of packets with the CLP bit set which have been transmitted onto the line from the bursty data A queue." ::= { trunkRTCEntry 30 } trunkRTCBurstyDataBClpPktsTx2Line OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC trunkRTCBurstyDataBClpPktsTx2Line -- C-NEXT-FUNC trunk-BurstyDataBClpPktsTx2Line-next -- C-PRE-GET-FUNC PreGet-trunkRTCBurstyDataBClpPktsTx2Line STATUS mandatory DESCRIPTION "The number of packets with the CLP bit set which have been transmitted onto the line from the bursty data B queue." ::= { trunkRTCEntry 31 } trunkRTCAtmCellHeaderHecErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC trunkRTCAtmCellHeaderHecErrors -- C-NEXT-FUNC trunk-AtmCellHeaderHecErrors-next -- C-PRE-GET-FUNC PreGet-trunkRTCAtmCellHeaderHecErrors STATUS mandatory DESCRIPTION "The number of ATM cell headers with HEC errors." ::= { trunkRTCEntry 32 } trunkRTCTxVoiceCellsDropped OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC trunkRTCTxVoiceCellsDropped -- C-NEXT-FUNC trunk-TxVoiceCellsDropped-next -- C-PRE-GET-FUNC PreGet-trunkRTCTxVoiceCellsDropped STATUS mandatory DESCRIPTION "The number of transmit voice cells dropped." ::= { trunkRTCEntry 33 } trunkRTCTxTimeStampCellsDropped OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC trunkRTCTxTimeStampCellsDropped -- C-NEXT-FUNC trunk-TxTimeStampCellsDropped-next -- C-PRE-GET-FUNC PreGet-trunkRTCTxTimeStampCellsDropped STATUS mandatory DESCRIPTION "The number of transmit time stamped cells dropped." ::= { trunkRTCEntry 34 } trunkRTCTxNonTStampCellsDropped OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC trunkRTCTxNonTStampCellsDropped -- C-NEXT-FUNC trunk-TxNonTStampCellsDropped-next -- C-PRE-GET-FUNC PreGet-trunkRTCTxNonTStampCellsDropped STATUS mandatory DESCRIPTION "The number of transmit non time stamped cells dropped." ::= { trunkRTCEntry 35 } trunkRTCTxHighPriorityCellsDropped OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC trunkRTCTxHighPriorityCellsDropped -- C-NEXT-FUNC trunk-TxHighPriorityCellsDropped-next -- C-PRE-GET-FUNC PreGet-trunkRTCTxHighPriorityCellsDropped STATUS mandatory DESCRIPTION "The number of transmit high priority cells dropped." ::= { trunkRTCEntry 36 } trunkRTCTxBurstyDataACellsDropped OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC trunkRTCTxBurstyDataACellsDropped -- C-NEXT-FUNC trunk-TxBurstyDataACellsDropped-next -- C-PRE-GET-FUNC PreGet-trunkRTCTxBurstyDataACellsDropped STATUS mandatory DESCRIPTION "The number of cells dropped from the bursty data A queue." ::= { trunkRTCEntry 37 } trunkRTCTxBurstyDataBCellsDropped OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC trunkRTCTxBurstyDataBCellsDropped -- C-NEXT-FUNC trunk-TxBurstyDataBCellsDropped-next -- C-PRE-GET-FUNC PreGet-trunkRTCTxBurstyDataBCellsDropped STATUS mandatory DESCRIPTION "The number of cells dropped from the bursty data B queue." ::= { trunkRTCEntry 38 } trunkRTCVoiceCellsTx2Line OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC trunkRTCVoiceCellsTx2Line -- C-NEXT-FUNC trunk-VoiceCellsTx2Line-next -- C-PRE-GET-FUNC PreGet-trunkRTCVoiceCellsTx2Line STATUS mandatory DESCRIPTION "The number of voice cells transmitted onto the line." ::= { trunkRTCEntry 39 } trunkRTCTimeStampCellsTx2Line OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC trunkRTCTimeStampCellsTx2Line -- C-NEXT-FUNC trunk-TimeStampCellsTx2Line-next -- C-PRE-GET-FUNC PreGet-trunkRTCTimeStampCellsTx2Line STATUS mandatory DESCRIPTION "The number of time stamped cells tranmsitted onto the line." ::= { trunkRTCEntry 40 } trunkRTCNonTimeStampCellsTx2Line OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC trunkRTCNonTimeStampCellsTx2Line -- C-NEXT-FUNC trunk-NonTimeStampCellsTx2Line-next -- C-PRE-GET-FUNC PreGet-trunkRTCNonTimeStampCellsTx2Line STATUS mandatory DESCRIPTION "The number of non time stamped cells tranmsitted onto the line." ::= { trunkRTCEntry 41 } trunkRTCHighPriorityCellsTx2Line OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC trunkRTCHighPriorityCellsTx2Line -- C-NEXT-FUNC trunk-HighPriorityCellsTx2Line-next -- C-PRE-GET-FUNC PreGet-trunkRTCHighPriorityCellsTx2Line STATUS mandatory DESCRIPTION "The number of high priority cells transmitted onto the line." ::= { trunkRTCEntry 42 } trunkRTCBurstyDataACellsTx2Line OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC trunkRTCBurstyDataACellsTx2Line -- C-NEXT-FUNC trunk-BurstyDataACellsTx2Line-next -- C-PRE-GET-FUNC PreGet-trunkRTCBurstyDataACellsTx2Line STATUS mandatory DESCRIPTION "The number of cells which have been transmitted onto the line from the bursty data A queue." ::= { trunkRTCEntry 43 } trunkRTCBurstyDataBCellsTx2Line OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC trunkRTCBurstyDataBCellsTx2Line -- C-NEXT-FUNC trunk-BurstyDataBCellsTx2Line-next -- C-PRE-GET-FUNC PreGet-trunkRTCBurstyDataBCellsTx2Line STATUS mandatory DESCRIPTION "The number of cells which have been transmitted onto the line from the bursty data B queue." ::= { trunkRTCEntry 44 } trunkRTCTotalCellsTx2Line OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC trunkRTCTotalCellsTx2Line -- C-NEXT-FUNC trunk-TotalCellsTx2Line-next -- C-PRE-GET-FUNC PreGet-trunkRTCTotalCellsTx2Line STATUS mandatory DESCRIPTION "The number of cells transmitted onto the line." ::= { trunkRTCEntry 45 } trunkRTCTxBurstyDataAClpCellsDropped OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC trunkRTCTxBurstyDataAClpCellsDropped -- C-NEXT-FUNC trunk-TxBurstyDataAClpCellsDropped-next -- C-PRE-GET-FUNC PreGet-trunkRTCTxBurstyDataAClpCellsDropped STATUS mandatory DESCRIPTION "The number of cells with the CLP bit set which have been dropped from the bursty data A queue." ::= { trunkRTCEntry 46 } trunkRTCTxBurstyDataBClpCellsDropped OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC trunkRTCTxBurstyDataBClpCellsDropped -- C-NEXT-FUNC trunk-TxBurstyDataBClpCellsDropped-next -- C-PRE-GET-FUNC PreGet-trunkRTCTxBurstyDataBClpCellsDropped STATUS mandatory DESCRIPTION "The number of cells with the CLP bit set which have been dropped from the bursty data B queue." ::= { trunkRTCEntry 47 } trunkRTCBurstyDataAEfcnCellsTx2Line OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC trunkRTCBurstyDataAEfcnCellsTx2Line -- C-NEXT-FUNC trunk-BurstyDataAEfcnCellsTx2Line-next -- C-PRE-GET-FUNC PreGet-trunkRTCBurstyDataAEfcnCellsTx2Line STATUS mandatory DESCRIPTION "The number of cells with the EFCN bit set which have been transmitted onto the line from the bursty data A queue." ::= { trunkRTCEntry 48 } trunkRTCBurstyDataBEfcnCellsTx2Line OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC trunkRTCBurstyDataBEfcnCellsTx2Line -- C-NEXT-FUNC trunk-BurstyDataBEfcnCellsTx2Line-next -- C-PRE-GET-FUNC PreGet-trunkRTCBurstyDataBEfcnCellsTx2Line STATUS mandatory DESCRIPTION "The number of cells with the EFCN bit set which have been transmitted onto the line from the bursty data B queue." ::= { trunkRTCEntry 49 } trunkRTCPlcpOutOfFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only -- C-ACCESS-FUNC trunkRTCPlcpOutOfFrames -- C-NEXT-FUNC trunk-PlcpOutOfFrames-next -- C-PRE-GET-FUNC PreGet-trunkRTCPlcpOutOfFrames STATUS mandatory DESCRIPTION "The number of out of frame conditions." ::= { trunkRTCEntry 50 } -- --------------------------------------------------------- -- Trap Config Table -- --------------------------------------------------------- trapConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF TrapConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table has the information about the manager receiving traps" ::= { trapsConfig 1 } trapConfigEntry OBJECT-TYPE SYNTAX TrapConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry of the manager table." INDEX { managerIPaddress } -- C-NEXT-FUNC mgr-next ::= { trapConfigTable 1 } TrapConfigEntry ::= SEQUENCE { managerIPaddress IpAddress, managerPortNumber INTEGER, managerRowStatus INTEGER, readingTrapFlag INTEGER, nextTrapSeqNum INTEGER } managerIPaddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write -- C-ACCESS-FUNC ip-address -- C-LOCATOR-FUNC mgr-locator STATUS mandatory DESCRIPTION " " ::= { trapConfigEntry 1 } managerPortNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-write -- C-ACCESS-FUNC port-number -- C-LOCATOR-FUNC mgr-locator STATUS mandatory DESCRIPTION " " ::= { trapConfigEntry 2 } managerRowStatus OBJECT-TYPE SYNTAX INTEGER { addRow (1), delRow (2) } ACCESS read-write -- C-ACCESS-FUNC row-status -- C-LOCATOR-FUNC mgr-locator STATUS mandatory DESCRIPTION "When RowStatus is set to addRow(1), the mgr is registered with the Proxy to receive the new traps generated." ::= { trapConfigEntry 3 } readingTrapFlag OBJECT-TYPE SYNTAX INTEGER { false (1), true (2) } ACCESS read-write -- C-ACCESS-FUNC reading-flag -- C-LOCATOR-FUNC mgr-locator STATUS mandatory DESCRIPTION " " ::= { trapConfigEntry 4 } nextTrapSeqNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-write -- C-ACCESS-FUNC trap-seqnum -- C-LOCATOR-FUNC mgr-locator STATUS mandatory DESCRIPTION " " ::= { trapConfigEntry 5 } managerNumOfValidEntries OBJECT-TYPE SYNTAX INTEGER(1..8) ACCESS read-only -- C-ACCESS-FUNC manager-entries STATUS mandatory DESCRIPTION "The number of managers in the table that are programmed to receive traps" ::= { trapsConfig 2 } lastSequenceNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT proxy-ctxt, FIELD lastTrapSeqNum STATUS mandatory DESCRIPTION "The Sequence Number of the last trap generated on the SNMP Proxy" ::= { trapsConfig 3 } ----------------------------------------------------------------------- -- RTM Group -- ----------------------------------------------------------------------- trapUploadTable OBJECT-TYPE SYNTAX SEQUENCE OF TrapUploadEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table has the information about the manager receiving traps" ::= { trapsConfig 4 } trapUploadEntry OBJECT-TYPE SYNTAX TrapUploadEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry of the manager table." INDEX { mgrIpAddress } -- C-NEXT-FUNC trap-next ::= { trapUploadTable 1 } TrapUploadEntry ::= SEQUENCE { mgrIpAddress IpAddress, trapSequenceNum INTEGER, trapPduString OCTET STRING, endOfQueueFlag INTEGER } mgrIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only -- C-ACCESS-FUNC mgrIpAddress -- C-LOCATOR-FUNC trap-locator STATUS mandatory DESCRIPTION " " ::= { trapUploadEntry 1 } trapSequenceNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-ACCESS-FUNC trapSequenceNum -- C-LOCATOR-FUNC trap-locator STATUS mandatory DESCRIPTION "The sequence number associated with tthe trap" ::= { trapUploadEntry 2 } trapPduString OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only -- C-ACCESS-FUNC trapPduString -- C-LOCATOR-FUNC trap-locator STATUS mandatory DESCRIPTION "The sequence number associated with tthe trap" ::= { trapUploadEntry 3 } endOfQueueFlag OBJECT-TYPE SYNTAX INTEGER { false(1), true(2) } ACCESS read-only -- C-ACCESS-FUNC endOfQueueFlag -- C-LOCATOR-FUNC trap-locator STATUS mandatory DESCRIPTION "The sequence number associated with tthe trap" ::= { trapUploadEntry 4 } -- -- control Group contains attributes associated with controlling -- logGroup as a whole. This group is mandatory databaseSampleFreq OBJECT-TYPE SYNTAX INTEGER (5..86400) ACCESS read-write -- C-STRUCT proxy-ctxt, FIELD dbSampleFreq STATUS mandatory DESCRIPTION "The desired rate (in seconds) at which the database should be queried for new log records that match any of the filter criteria from the Event Filter Table. The agent may optionally poll more or less frequently then specified by this variable. The value of this variable is only a suggestion to the agent." DEFVAL { 60 } ::= { controlGroup 1 } ----------------------------------------------------------------------- -- Log Group. ----------------------------------------------------------------------- currentMaxLogIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-ACCESS-FUNC MaxLogIndex STATUS mandatory DESCRIPTION "The current max value of logIndex. This value may change with time." ::= { logGroup 1 } ----------------------------------------------------------------------- -- Maint Log Table ----------------------------------------------------------------------- maintLogTable OBJECT-TYPE SYNTAX SEQUENCE OF MaintLogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table of log entries." ::= { logGroup 2 } maintLogEntry OBJECT-TYPE SYNTAX MaintLogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the log table." INDEX { logIndex } -- C-NEXT-FUNC log-next ::= { maintLogTable 1 } MaintLogEntry ::= SEQUENCE { logIndex INTEGER, logNetwork DisplayString, logNodeName DisplayString, logGmtDate DisplayString, logSeverity Severity, logMsg DisplayString } logIndex OBJECT-TYPE SYNTAX INTEGER (1..1073741824) ACCESS read-only -- C-STRUCT log-record, FIELD logIndex -- C-LOCATOR-FUNC log-locator STATUS mandatory DESCRIPTION "Unique index of the Log record." ::= { maintLogEntry 1 } logNetwork OBJECT-TYPE SYNTAX DisplayString (SIZE (0..10)) ACCESS read-only -- C-STRUCT log-record, FIELD logNetwork -- C-LOCATOR-FUNC log-locator STATUS mandatory DESCRIPTION "Name of the network for which this log entry was generated." ::= { maintLogEntry 2 } logNodeName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..10)) ACCESS read-only -- C-STRUCT log-record, FIELD logNodeName -- C-LOCATOR-FUNC log-locator STATUS mandatory DESCRIPTION "Name of the IPX node for this this log entry was generated." ::= { maintLogEntry 3 } logGmtDate OBJECT-TYPE SYNTAX DisplayString (SIZE (19)) ACCESS read-only -- C-STRUCT log-record, FIELD logGmtDate -- C-LOCATOR-FUNC log-locator STATUS mandatory DESCRIPTION "ASCII formatted string indicating the GMT date and time for this log record in the format (yyyy-mm-dd hh:mm:ss). This is the time reported by the IPX which generated the event." ::= { maintLogEntry 4 } logSeverity OBJECT-TYPE SYNTAX Severity ACCESS read-only -- C-STRUCT log-record, FIELD logSeverity -- C-LOCATOR-FUNC log-locator STATUS mandatory DESCRIPTION "The severity of this log record." ::= { maintLogEntry 5 } logMsg OBJECT-TYPE SYNTAX DisplayString (SIZE (0..256)) ACCESS read-only -- C-STRUCT log-record, FIELD logMsg -- C-LOCATOR-FUNC log-locator STATUS mandatory DESCRIPTION "An ASCII message associated with this log record." ::= { maintLogEntry 6 } ----------------------------------------------------------------------- -- Event Filtering Table ----------------------------------------------------------------------- -- -- In order for a manager to create a row of this table, a -- single SET request should be sent with all the variables -- for every column specified. -- -- In order for a manager to delete a row of this table, a -- single SET requets should be sent to change the -- eventFilterStatus column from 'active' to 'invalid'. -- -- For a new log record to be forwarded as a TRAP the following -- must be true: -- -- eventFilterStatus must be 'active'. -- -- eventFilterSeverity must exactly match the logSeverity -- of the log record. -- -- eventFilterSubstring must contain a string that is -- found in the logMsg variable of the -- log record. -- -- To request all events of all severity levels, set both the -- eventFilterSeverity and eventFilterSubstring elements to -- be zero-length strings. -- eventFilterTable OBJECT-TYPE SYNTAX SEQUENCE OF EventFilterEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table of Event Filters." ::= { logGroup 3 } eventFilterEntry OBJECT-TYPE SYNTAX EventFilterEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Event Filter table. Each entry in this table describes a set of log entry criteria, and entries in the log that match these criteria will be forwarded as SNMP TRAPS." INDEX { eventFilterIndex } -- C-NEXT-FUNC filter-next ::= { eventFilterTable 1 } EventFilterEntry ::= SEQUENCE { eventFilterIndex INTEGER, eventFilterStatus INTEGER, eventFilterSeverity Severity, eventFilterSubstring DisplayString } eventFilterIndex OBJECT-TYPE SYNTAX INTEGER ( 1 .. 2147483647) ACCESS read-write -- C-ACCESS-FUNC filter-index -- C-LOCATOR-FUNC filter-locator-ind STATUS mandatory DESCRIPTION "The unique index for each entry of this table. This entry can only be written with the first SET command to create a new row of this table." ::= { eventFilterEntry 1 } eventFilterStatus OBJECT-TYPE SYNTAX INTEGER { invalid (1), active (2) } ACCESS read-write -- C-ACCESS-FUNC filter-status -- C-LOCATOR-FUNC filter-locator STATUS mandatory DESCRIPTION "'active' indicates that this row of the table is currently generating filtered TRAPs. When in this state, any entry added to the log table with logSeverity matching eventFilterSeverity and logMsg containing the eventFilterSubstring text, this information will be forwarded as a TRAP. 'invalid' indicates that this row of the table is no longer generating filtered TRAPs. A conforming agent may either leave the row with the 'invalid' value in the table, or may delete the row from the table." DEFVAL { active } ::= { eventFilterEntry 2 } eventFilterSeverity OBJECT-TYPE SYNTAX Severity ACCESS read-write -- C-ACCESS-FUNC filter-severity -- C-LOCATOR-FUNC filter-locator STATUS mandatory DESCRIPTION "The eventFilterSeverity specifies the severity of log records to be forwarded on as SNMP TRAPS by this event filter entry. The value of eventFilterSeverty must exactly match the value of logSeverity for there to be a chance that a new log record will be forwarded as a TRAP. An eventFilterSeverity of length 0 matches all severity levels." DEFVAL { ''h } ::= { eventFilterEntry 3 } eventFilterSubstring OBJECT-TYPE SYNTAX DisplayString (SIZE (0..256)) ACCESS read-write -- C-ACCESS-FUNC filter-substring -- C-LOCATOR-FUNC filter-locator STATUS mandatory DESCRIPTION "The eventFilterSubstring variable specifies an ASCII substring that must appear in the logMsg field of a log record in order for there to be a chance that for the log record to forwarded as a TRAP. If this variable contains a zero length string, the substring comparison will always SUCCEED for this event filter entry." DEFVAL { ''h } ::= { eventFilterEntry 4 } -- -- maintLog Table Filter Group -- -- This group is optional and may be used to support filtering -- GetNext requests when retrieving elements from the -- mainLogTable. If the group is supported then all attributes -- in the group are mandatory. -- -- maintLogFilterGroup OBJECT IDENTIFIER ::= { logGroup 4 } -- When applying the maintLogFilterGroup attributes during an -- SNMP Operation, the order is important. The attributes will -- be applied in the following order: -- maintLogFilterTimeMin -- maintLogFilterTimeMax -- maintLogFilterNetworkName -- maintLogFilterNodeName -- maintLogFilterSeverity -- maintLogFilterWindow -- maintLogFilterTimeMin OBJECT-TYPE SYNTAX DisplayString(SIZE(0..22)) ACCESS read-write -- C-ACCESS-FUNC MaintLogFilterTimeMin -- C-LOCATOR-FUNC MaintFilterLocator STATUS mandatory DESCRIPTION "When maintLogFilterTimeMin has a value other than a 0 length string, the value is used as a minimum value for maintLogFilterGmtDate to qualify entries in the maintLogTable. The string is formated as yyyy-mm-dd hh:mm:ss" DEFVAL { ''h } ::= { maintLogFilterGroup 1 } maintLogFilterTimeMax OBJECT-TYPE SYNTAX DisplayString(SIZE(0..22)) ACCESS read-write -- C-ACCESS-FUNC MaintLogFilterTimeMax -- C-LOCATOR-FUNC MaintFilterLocator STATUS mandatory DESCRIPTION "When maintLogFilterTimeMax has a value other than a 0 length string, the value is used as a maximum value for maintLogFilterGmtDate to qualify entries in the maintLogTable. The string is formated as yyyy-mm-dd hh:mm:ss" DEFVAL { ''h } ::= { maintLogFilterGroup 2 } maintLogFilterWindow OBJECT-TYPE SYNTAX INTEGER ACCESS read-write -- C-ACCESS-FUNC MaintLogFilterWindow -- C-LOCATOR-FUNC MaintFilterLocator STATUS mandatory DESCRIPTION "When maintLogFilterWindow has a value other than 0, the value is used to qualify entries in the maintLogTable. This attribute has the effect of limiting the view in the maintLogTable to the number specified by the value of this attribute. If after applying the other maintLogFilter attributes, the remaining set exceeds the value of maintLogFilterWindow then, the set of entries which can be viewed is limited to the top N based on the logIndex value." DEFVAL { 30 } ::= { maintLogFilterGroup 3 } maintLogFilterNetworkName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..10)) ACCESS read-write -- C-ACCESS-FUNC MaintLogFilterNetwork -- C-LOCATOR-FUNC MaintFilterLocator STATUS mandatory DESCRIPTION "When maintLogFilterNetworkName has a value other than a 0 length string, then the value of this attribute is used to qualify entries in the maintLogTable. This value must match logNetwork exactly to pass the filter." DEFVAL { ''h } ::= { maintLogFilterGroup 4 } maintLogFilterNodeName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..10)) ACCESS read-write -- C-ACCESS-FUNC MaintLogFilterNode -- C-LOCATOR-FUNC MaintFilterLocator STATUS mandatory DESCRIPTION "When maintLogFilterNodeName has a value other than a 0 length string, then the value of this attribute is used to qualify entries in the maintLogTable. This value must match logNodeName exactly to pass the filter." DEFVAL { ''h } ::= { maintLogFilterGroup 5 } maintLogFilterSeverity OBJECT-TYPE SYNTAX Severity ACCESS read-write -- C-ACCESS-FUNC MaintLogFilterSeverity -- C-LOCATOR-FUNC MaintFilterLocator STATUS mandatory DESCRIPTION "When maintLogFilterSeverity has a value other than a 0 length string, then the value is used to qualify entries in the maintLogTable. The value must match the logSeverity exactly to pass the filter." DEFVAL { ''h } ::= { maintLogFilterGroup 6 } ----------------------------------------------------------------------- -- Network Group ----------------------------------------------------------------------- ----------------------------------------------------------------------- -- Network Table ----------------------------------------------------------------------- networkTable OBJECT-TYPE SYNTAX SEQUENCE OF NetworkEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table of Networks." ::= { networkGroup 1 } networkEntry OBJECT-TYPE SYNTAX NetworkEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Network table." INDEX { networkName } -- C-NEXT-FUNC net-next ::= { networkTable 1 } NetworkEntry ::= SEQUENCE { networkName DisplayString, networkId INTEGER, networkIpxId INTEGER } networkName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..10)) ACCESS read-only -- C-STRUCT network-cfg, FIELD networkName -- C-LOCATOR-FUNC net-locator STATUS mandatory DESCRIPTION "The name of the network as assigned by the StrataView User." ::= { networkEntry 1 } networkId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT network-cfg, FIELD networkId -- C-LOCATOR-FUNC net-locator STATUS mandatory DESCRIPTION "The unique ID of the network as assigned by the StrataView system." ::= { networkEntry 2 } networkIpxId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-STRUCT network-cfg, FIELD networkIpxId -- C-LOCATOR-FUNC net-locator STATUS mandatory DESCRIPTION "The IPX network ID." ::= { networkEntry 3 } ----------------------------------------------------------------------- -- Node Group ----------------------------------------------------------------------- ----------------------------------------------------------------------- -- Node Table ----------------------------------------------------------------------- nodeTable OBJECT-TYPE SYNTAX SEQUENCE OF NodeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table of Nodes." ::= { nodeGroup 1 } nodeEntry OBJECT-TYPE SYNTAX NodeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Node table." INDEX { nodeNetworkName, nodeName } -- C-NEXT-FUNC EventNodeNext ::= { nodeTable 1 } NodeEntry ::= SEQUENCE { nodeNetworkName DisplayString, nodeName DisplayString } nodeNetworkName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..10)) ACCESS read-only -- C-STRUCT node-cfg, FIELD nodeNetName -- C-LOCATOR-FUNC EventNodeLocator STATUS mandatory DESCRIPTION "The name of the network to which this node is attached." ::= { nodeEntry 1 } nodeName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..10)) ACCESS read-only -- C-STRUCT node-cfg, FIELD nodeName -- C-LOCATOR-FUNC EventNodeLocator STATUS mandatory DESCRIPTION "IPX node name." ::= { nodeEntry 2 } -- -- Trap Definitions -- trunkStatusAlarm TRAP-TYPE ENTERPRISE svnode VARIABLES { lastSequenceNumber, nodeGrpName, nodeGrpNetName, trunkStatus } DESCRIPTION "This trap is generated whenever an ObjectAlarm Status message is received containing the trunk status." ::= 0 cirLineStatusAlarm TRAP-TYPE ENTERPRISE svnode VARIABLES { lastSequenceNumber, nodeGrpName, nodeGrpNetName, cirLineStatus } DESCRIPTION "This trap is generated whenever an ObjectAlarm Status message is received containing the cirLineStatus." ::= 1 frpStatusAlarm TRAP-TYPE ENTERPRISE svnode VARIABLES { lastSequenceNumber, nodeGrpName, nodeGrpNetName, frpStatus } DESCRIPTION "This trap is generated whenever an ObjectAlarm Status message is received containing the frpStatus." ::= 2 connStatusAlarm TRAP-TYPE ENTERPRISE svnode VARIABLES { lastSequenceNumber, nodeGrpName, nodeGrpNetName, connStatus, connABitStatus } DESCRIPTION "This trap is generated whenever an ObjectAlarm Status message is received containing the connStatus." ::= 3 filteredLogRecord TRAP-TYPE ENTERPRISE svplus VARIABLES { lastSequenceNumber, logIndex, logNetwork, logNodeName, logGmtDate, logSeverity, logMsg } DESCRIPTION "The 'filteredLogRecord' trap is generated by the StrataView system whenever an entry in the eventFilterTable matches a log record that is added to the StrataView database." ::= 4 -- END -- -- Stratacom StrataView Service MIBs -- -- $RCSfile: SV+Service.mib,v $ -- $Revision: 1.1.4.35 $ -- $Date: 1996/07/25 22:12:54 $ -- -- Consolidated MIB for port and connection services -- -- Revision: 8/6/95 -- Corrected the errors pointed out by AT&T. -- -- changed name of connTable to connectionTable -- because of conflict with Stratacom Node mib. -- -- Added line number as an index -- into the frEnptPtTable to support AXIS nodes. -- -- STRATACOM-STRATAVIEW-SVPLUS-MIB -- DEFINITIONS ::= BEGIN -- IMPORTS -- enterprises, Counter, Gauge, TimeTicks, IpAddress FROM RFC1155-SMI -- TRAP-TYPE FROM RFC-1215 -- OBJECT-TYPE FROM RFC-1212 -- DisplayString FROM RFC1213-MIB; -- stratacom OBJECT IDENTIFIER ::= { enterprises 351 } -- svplus OBJECT IDENTIFIER ::= { stratacom 1 } connSvc OBJECT IDENTIFIER ::= { stratacom 3 } portSvc OBJECT IDENTIFIER ::= { stratacom 4 } -- rtm OBJECT IDENTIFIER ::= { stratacom 120 } -- -- -- This MIB defines tables and attributes creating and maintaining -- connections and their end points. A connection is defined as end to end; -- each end designated as an user end point, one of which is called 'local' -- and other is called 'remote'. The end to end connection consists of -- one or more connection segments which are defined in the segment -- table. A key attribute controlling the existence of entries in each of -- the tables is the 'RowStatus' as defined in RFC 1443 - Textual -- Conventions for version 2 of the Simple Network Management Protocol -- (SNMPv2). However, since this MIB is implemented using version 1, -- RowStatus is defined below and RFC1443 return error code mappings are: -- -- 'inconsistant value' or 'wrong value' then return 'badValue'; -- 'noSuchObject' or 'noSuchInstance' then return 'noSuchName' -- -- To create a connection: -- -- 1. The manager creates the entries in the respective end point -- table(s) and the connectionTable, with RowStatus is set to -- 'createAndGo'. The required attributes for end points as well as -- connectionEntry also can be specified in the same SET request. -- Note that value 0 must be used as connectionIndex -- for creating entry in the connectionTable. -- [ The actual index is internally generated by Proxy ] -- -- 2. Once Step-2 is successful, -- segmentTable for each connection segment of the connection will exist. -- This may consist of 1 or more segments -- depending on the underlying network configuration. -- Note that segment table is read-only. -- -- Table Entry Deletion -- -- To delete an entry in any of the tables, set the rowStatus to -- 'destroy'. Deleting the connectionEntry will delete all corresponding -- entries in the associated EndPoint and Segment Tables. -- -- A protocol specific end point may be deleted only if it is not associated -- with any connectionEntry or segmentEntry. -- -- RowStatus ::= INTEGER { -- active(1), -- createAndGo(4), -- destroy(6) -- } connMibUpTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only -- C-ACCESS-FUNC connMibUpTime STATUS mandatory DESCRIPTION "the equivalent of sysUpTime for this MIB, its the elapsed time since the management entity supporting this mib is started. If the entity is the same as that supporting MIB II sysUpTime than this attribute is the same as sysUpTime." ::= { connSvc 1 } connAvailIndex OBJECT-TYPE SYNTAX INTEGER (0..0) ACCESS read-only -- C-ACCESS-FUNC connAvailIndex STATUS mandatory DESCRIPTION "This object is not required any more because now connectionIndex is internally generated by the Proxy itself. User is required to use connectionIndex=0 for adding connections. This object is kept for the backward compatibilty. GET on this object always returns 0" ::= { connSvc 2 } connectionTable OBJECT-TYPE SYNTAX SEQUENCE OF ConnectionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A List of Connection Virtual Circuit Entries" ::= { connSvc 3 } connectionEntry OBJECT-TYPE SYNTAX ConnectionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A General Connection Entry" INDEX { connectionIndex } -- C-NEXT-FUNC NextConnEntry ::= { connectionTable 1 } ConnectionEntry ::= SEQUENCE { connectionIndex INTEGER, connectionLocalEndPt OBJECT IDENTIFIER, connectionRemoteEndPt OBJECT IDENTIFIER, connectionOpStatus INTEGER, connectionAdminStatus INTEGER, connectionRowStatus INTEGER, connectionTrkAvoidType INTEGER, connectionTrkAvoidZCS INTEGER, connectionClassOfService INTEGER, connectionForesight INTEGER, connectionCurrRouteDesc DisplayString, connectionPrefRouteDesc DisplayString, connRouteMaster DisplayString, connectionLocOSpacePkts INTEGER, connectionLocOSpaceBdaCmax INTEGER, connectionLocOSpaceBdbCmax INTEGER, connectionRemOSpacePkts INTEGER, connectionRemOSpaceBdaCmax INTEGER, connectionRemOSpaceBdbCmax INTEGER, connectionTestType INTEGER, connectionTestResult INTEGER, connectionAbitStatus INTEGER, connectionType INTEGER, connectionLocalStr DisplayString, connectionRemoteStr DisplayString } connectionIndex OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only -- C-ACCESS-FUNC connIndex -- C-LOCATOR-FUNC LocateConnEntry STATUS mandatory DESCRIPTION "A unique value greater than 0 for each entry in the table. The value assigned must remain constant at least from one reinitialization of the managment entity and the next. Special value 0 must be used for adding new rows in the table. The actual index will be generated internally by the Proxy." ::= { connectionEntry 1 } connectionLocalEndPt OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-write -- C-ACCESS-FUNC connLocalEndPt -- C-LOCATOR-FUNC LocateConnEntry STATUS mandatory DESCRIPTION "The object identifier of the 1st attribute of the end point in the associated protocol specific end point table." ::= { connectionEntry 2 } connectionRemoteEndPt OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-write -- C-ACCESS-FUNC connRemoteEndPt -- C-LOCATOR-FUNC LocateConnEntry STATUS mandatory DESCRIPTION "The object identifier of the 1st attribute of the end point in the associated protocol specific end point table. " ::= { connectionEntry 3 } connectionAdminStatus OBJECT-TYPE SYNTAX INTEGER { inactive(1), active(2), testing(3) } ACCESS read-write -- C-ACCESS-FUNC connAdminStatus -- C-LOCATOR-FUNC LocateConnEntry STATUS mandatory DESCRIPTION " Administrative status of the connection. This attribute may be set to 'testing' only when connectionOpStatus has the value 'clear'." ::= { connectionEntry 4 } connectionOpStatus OBJECT-TYPE SYNTAX INTEGER { inactive(1), clear(2), fail(3), down(4), incomplete(5) } ACCESS read-only -- C-ACCESS-FUNC connOpStatus -- C-LOCATOR-FUNC LocateConnEntry STATUS mandatory DESCRIPTION "A operation status of the connection. 'incomplete' indicates that the some segments of the connection exist but others may be in an unknown or non-existant state." ::= { connectionEntry 5 } connectionRowStatus OBJECT-TYPE SYNTAX INTEGER { active(1), createAndGo(4), destroy(6) } ACCESS read-write -- C-ACCESS-FUNC connRowStatus -- C-LOCATOR-FUNC LocateConnEntry STATUS mandatory DESCRIPTION "To create an entry in this table, set the value of this object to 'createAndGo'. To delete the connection and the corresponding end points set the value to 'destroy'. setting the value to active will result in bad value. Other required parameters can also be set in the same request" ::= { connectionEntry 6 } connectionTrkAvoidType OBJECT-TYPE SYNTAX INTEGER { none(1), satellite(2), terrestrial(3) } ACCESS read-write -- C-ACCESS-FUNC connTrkAvoidType -- C-LOCATOR-FUNC LocateConnEntry STATUS mandatory DESCRIPTION "User selectable types of trunks to avoid for the transfer of data. Current choices are to avoid satellite links, terrestrial links, or to not avoid any specific type of link." DEFVAL { none } ::= { connectionEntry 7 } connectionTrkAvoidZCS OBJECT-TYPE SYNTAX INTEGER { false(1), true(2) } ACCESS read-write -- C-ACCESS-FUNC connTrkAvoidZCS -- C-LOCATOR-FUNC LocateConnEntry STATUS mandatory DESCRIPTION "Flag to force the connection to avoid trunks with zero code suppression (ZCS). " DEFVAL { false } ::= { connectionEntry 8 } connectionForesight OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write -- C-ACCESS-FUNC connForesight -- C-LOCATOR-FUNC LocateConnEntry STATUS mandatory DESCRIPTION "Flag to enable/disable foresight." DEFVAL { disable } ::= { connectionEntry 9 } connectionClassOfService OBJECT-TYPE SYNTAX INTEGER (0..15) ACCESS read-write -- C-ACCESS-FUNC connClassOfService -- C-LOCATOR-FUNC LocateConnEntry STATUS mandatory DESCRIPTION "A class of service for this connection. The lower the class value, the higher the routing priority of the connection." DEFVAL { 0 } ::= { connectionEntry 10 } connectionCurrRouteDesc OBJECT-TYPE SYNTAX DisplayString (SIZE(0..256)) ACCESS read-only -- C-ACCESS-FUNC connCurrRouteDesc -- C-LOCATOR-FUNC LocateConnEntry STATUS mandatory DESCRIPTION "A description of the current route. Descriptor gives information about the domain, nodename, slot, and possibly a port for each hop in the route. For example, Node1 15 - 15Node2 is a valid route specifying a terrestrial link between Node1 slot 15 and Node2 slot 15. The following describes the general format for connectionCurrRouteDesc: (.[.0])* - (.)* - Some more valid descriptions are: 1) Node1.15.1 - Node2.13.1 - Node3 2) Node1.15.1-Node2.13.1-Node3 3) Node1.15 - Node2.12 - Node3.15 - Node4 4) Node1.15.0 - Node2.12.0 - Node3.15.0 - Node4 5) Node2 NOTE: a> (...)* notation means the description inside parenthesis may repeat any number of times, only limited by the total length which is 255 and the [...] notation signifies that it is optional. b> 1) & 2) are equivalent so are 3) & 4). " ::= { connectionEntry 11 } connectionPrefRouteDesc OBJECT-TYPE SYNTAX DisplayString (SIZE(0..256)) ACCESS read-write -- C-ACCESS-FUNC connPrefRouteDesc -- C-LOCATOR-FUNC LocateConnEntry STATUS mandatory DESCRIPTION "Descriptor of the preferred route (all hops specified). Descriptor gives information about the domain, nodename, slot, and possibly a port for each hop in the route. For example, Node1.15 - Node2 is a valid route specifying a terrestrial link between Node1 slot 15 and Node2. The following describes the general format for connectionPrefRouteDesc: (.[.0])* - (.)* - Some more valid descriptions are: 1) Node1.15.1 - Node2.13.1 - Node3 2) Node1.15.1-Node2.13.1-Node3 3) Node1.15 - Node2.12 - Node3.15 - Node4 4) Node1.15.0 - Node2.12.0 - Node3.15.0 - Node4 5) Node2 NOTE: a> (...)* notation means the description inside parenthesis may repeat any number of times, only limited by the total length which is 255 and the [...] notation signifies that it is optional. b> 1) & 2) are equivalent so are 3) & 4). " DEFVAL { ''h } ::= { connectionEntry 12 } connRouteMaster OBJECT-TYPE SYNTAX DisplayString (SIZE(0..10)) ACCESS read-only -- C-ACCESS-FUNC connRouteMaster -- C-LOCATOR-FUNC LocateConnEntry STATUS mandatory DESCRIPTION "The node name of the route master." ::= { connectionEntry 13 } connectionLocOSpacePkts OBJECT-TYPE SYNTAX INTEGER (-1..2147483647) ACCESS read-only -- C-ACCESS-FUNC connLocOSpacePkts -- C-LOCATOR-FUNC LocateOSpace STATUS mandatory DESCRIPTION "This variable provides the minimum packet load available on the mandatory path of this connection in local->remote direction. This variable is determined by comparing available bandwidth on every trunk on which the connection is mandatoryly routed and reporting the minimum available bandwidth. For interdomain connections this value represents available bandwidth through all domains. This variable is meaningful for routed connections only. Value (-1) is returned in case of internal errors and (0) is returned for DAX connections. These values are returned in packets per second." ::= { connectionEntry 14 } connectionLocOSpaceBdaCmax OBJECT-TYPE SYNTAX INTEGER (-1..65534) ACCESS read-only -- C-ACCESS-FUNC connLocOSpaceBdaCmax -- C-LOCATOR-FUNC LocateOSpace STATUS mandatory DESCRIPTION "This variable provides the minimum BData A Cmax available on the mandatory path of this connection in local->remote direction. This variable is determined by comparing available BData A Cmax on every trunk on which the connection is mandatoryly routed and reporting the minumim available. For interdomain connections this value represents available BData A Cmax through all domains. This variable is meaningful for routed connections only. Value (-1) is returned in case of internal errors and (0) is returned for DAX connections. These values are returned in bytes." ::= { connectionEntry 15 } connectionLocOSpaceBdbCmax OBJECT-TYPE SYNTAX INTEGER (-1..65534) ACCESS read-only -- C-ACCESS-FUNC connLocOSpaceBdbCmax -- C-LOCATOR-FUNC LocateOSpace STATUS mandatory DESCRIPTION "This variable provides the minimum BData B Cmax available on the mandatory path of this connection in local->remote direction. This variable is determined by comparing available BData B Cmax on every trunk on which the connection is mandatoryly routed and reporting the minumim available. For interdomain connections this value represents available BData B Cmax through all domains. This variable is meaningful for routed connections only. Value (-1) is returned in case of internal errors and (0) is returned for DAX connections. These values are returned in bytes." ::= { connectionEntry 16 } connectionRemOSpacePkts OBJECT-TYPE SYNTAX INTEGER (-1..2147483647) ACCESS read-only -- C-ACCESS-FUNC connRemOSpacePkts -- C-LOCATOR-FUNC LocateOSpace STATUS mandatory DESCRIPTION "This variable provides the minimum packet load available on the mandatory path of this connection in remote->local direction. This variable is determined by comparing available bandwidth on every trunk on which the connection is mandatoryly routed and reporting the minumim available bandwidth. For interdomain connections this value represents available bandwidth through all domains. This variable is meaningful for routed connections only. Value (-1) is returned in case of internal errors and (0) is returned for DAX connections. These values are returned in packets per second." ::= { connectionEntry 17 } connectionRemOSpaceBdaCmax OBJECT-TYPE SYNTAX INTEGER (-1..65534) ACCESS read-only -- C-ACCESS-FUNC connRemOSpaceBdaCmax -- C-LOCATOR-FUNC LocateOSpace STATUS mandatory DESCRIPTION "This variable provides the minimum BData A Cmax available on the mandatory path of this connection in remote->local direction. This variable is determined by comparing available BData A Cmax on every trunk on which the connection is mandatoryly routed and reporting the minumim available. For interdomain connections this value represents available BData A Cmax through all domains. This variable is meaningful for routed connections only. Value (-1) is returned in case of internal errors and (0) is returned for DAX connections. These values are returned in bytes." ::= { connectionEntry 18 } connectionRemOSpaceBdbCmax OBJECT-TYPE SYNTAX INTEGER (-1..65534) ACCESS read-only -- C-ACCESS-FUNC connRemOSpaceBdbCmax -- C-LOCATOR-FUNC LocateOSpace STATUS mandatory DESCRIPTION "This variable provides the minimum BData B Cmax available on the mandatory path of this connection in remote->local direction. This variable is determined by comparing available BData B Cmax on every trunk on which the connection is mandatoryly routed and reporting the minumim available. For interdomain connections this value represents available BData B Cmax through all domains. This variable is meaningful for routed connections only. Value (-1) is returned in case of internal errors and (0) is returned for DAX connections. These values are returned in bytes." ::= { connectionEntry 19 } connectionTestType OBJECT-TYPE SYNTAX INTEGER { continuity(1), delay(2), none(255) } ACCESS read-write -- C-ACCESS-FUNC connTestType -- C-LOCATOR-FUNC LocateConnEntry STATUS mandatory DESCRIPTION "Specifies the type of test to be conducted on this connection. The test is executed when both this attribute is set to the appropriate test and connectionAdminStatus is SET to 'testing'. The 'continuity' test verifies continuity. The 'delay' test on successful completion sets the delay in msecs in connectionTestResult. This attribute may be set only when connectionOpStatus has the value 'clear', 'fail', or 'down'." DEFVAL { none } ::= { connectionEntry 20 } connectionTestResult OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-ACCESS-FUNC connTestResult -- C-LOCATOR-FUNC LocateConnEntry STATUS mandatory DESCRIPTION "This object holds the result of an executed connection test. If a continuity test is executed, this object contains the value 0 if successful, or -2 if failed. If a delay test successfully executed, this object will indicate the round trip delay (in milliseconds) for the connection. If the delay test failed this object contains the value -2. If no test has been executed, or the connectionTestType is SET, then this object will return the value -1." ::= { connectionEntry 21 } connectionAbitStatus OBJECT-TYPE SYNTAX INTEGER { clear(1), fail(2) } ACCESS read-only -- C-ACCESS-FUNC connAbitStatus -- C-LOCATOR-FUNC LocateConnEntry STATUS mandatory DESCRIPTION "A-bit status of the connection." ::= { connectionEntry 22 } connectionType OBJECT-TYPE SYNTAX INTEGER { fr(1), atm(2), atm-fr(3), unknown(20) } ACCESS read-only -- C-ACCESS-FUNC connType -- C-LOCATOR-FUNC LocateConnEntry STATUS mandatory DESCRIPTION "Connection Type. fr indicates Framerelay to Framerelay connection. atm indicates Atm to Atm connection and atm-fr indicates Atm to FrameRelay connection. unknown indicates incomplete connection." ::= { connectionEntry 23 } connectionLocalStr OBJECT-TYPE SYNTAX DisplayString ACCESS read-only -- C-ACCESS-FUNC connLocalStr -- C-LOCATOR-FUNC LocateConnEntry STATUS mandatory DESCRIPTION "The Local EndPt information in string format. i.e., the instance information of the EndPt. Framerelay Endpt is displayed as: node.shelf.slot.line.port.dlci Atm Endpt is displayed as: node.shelf.slot.port.vpi.vci shelf is 0 for Endpt on a routing node." ::= { connectionEntry 24 } connectionRemoteStr OBJECT-TYPE SYNTAX DisplayString ACCESS read-only -- C-ACCESS-FUNC connRemoteStr -- C-LOCATOR-FUNC LocateConnEntry STATUS mandatory DESCRIPTION "The Remote EndPt information in string format. i.e., the instance information of the EndPt. Framerelay Endpt is displayed as: node.shelf.slot.line.port.dlci Atm Endpt is displayed as: node.shelf.slot.port.vpi.vci shelf is 0 for Endpt on a routing node." ::= { connectionEntry 25 } -- -- The Frame Relay end point table. -- -- Each connection (virtual circuit or PVC) end-point describes the -- particular characteristics of the end-point. Such information -- as bandwidth parameters are maintained in the end-point. -- frEndPtTable OBJECT-TYPE SYNTAX SEQUENCE OF FrEndPtEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A List of frame relay virtual circuit end points" ::= { connSvc 4 } frEndPtEntry OBJECT-TYPE SYNTAX FrEndPtEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A frame relay end point Entry" INDEX { frEndPtNodeName, frEndPtIfShelf, frEndPtSlot, frEndPtLine, frEndPtPort, frEndPtDlci } -- C-NEXT-FUNC NextFrEntry ::= { frEndPtTable 1 } FrEndPtEntry ::= SEQUENCE { frEndPtNodeName DisplayString, frEndPtIfShelf DisplayString, frEndPtSlot INTEGER, frEndPtLine INTEGER, frEndPtPort INTEGER, frEndPtDlci INTEGER, frEndPtConnIndex INTEGER, frEndPtAdminStatus INTEGER, frEndPtOpStatus INTEGER, frEndPtRowStatus INTEGER, frEndPtMIR INTEGER, frEndPtCIR INTEGER, frEndPtBc INTEGER, frEndPtBe INTEGER, frEndPtVcQSize INTEGER, frEndPtPIR INTEGER, frEndPtCMAX INTEGER, frEndPtEcnQSize INTEGER, frEndPtQIR INTEGER, frEndPtPercUtil INTEGER, frEndPtPriority INTEGER, frEndPtInitialBurstSize INTEGER, frEndPtDeTagging INTEGER, frEndPtIngressDeThreshold INTEGER, frEndPtEgressQDepth INTEGER, frEndPtEgressDeThreshold INTEGER, frEndPtEgressEcnThreshold INTEGER, frEndPtEgressQSelect INTEGER, frEndPtLpbkState INTEGER, frEndPtType INTEGER, frEndPtchanType INTEGER, frEndPtchanFECNconfig INTEGER, frEndPtchanDEtoCLPmap INTEGER, frEndPtchanCLPtoDEmap INTEGER } frEndPtNodeName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..10)) ACCESS read-write -- C-ACCESS-FUNC FrEndPtNodeName -- C-LOCATOR-FUNC LocateFrEntry STATUS mandatory DESCRIPTION "The node name." ::= { frEndPtEntry 1 } frEndPtIfShelf OBJECT-TYPE SYNTAX DisplayString (SIZE(0..10)) ACCESS read-write -- C-ACCESS-FUNC FrEndPtIfShelf -- C-LOCATOR-FUNC LocateFrEntry STATUS mandatory DESCRIPTION "String identifying the shelf. This is a null string for end points which do not have a shelf name." ::= { frEndPtEntry 2 } frEndPtSlot OBJECT-TYPE SYNTAX INTEGER (1..64) ACCESS read-write -- C-ACCESS-FUNC FrEndPtSlot -- C-LOCATOR-FUNC LocateFrEntry STATUS mandatory DESCRIPTION "Slot Number." ::= { frEndPtEntry 3 } frEndPtLine OBJECT-TYPE SYNTAX INTEGER (0..8) ACCESS read-write -- C-ACCESS-FUNC FrEndPtLine -- C-LOCATOR-FUNC LocateFrEntry STATUS mandatory DESCRIPTION "Line Number. If no line number is associated with the end point then this value is 0." ::= { frEndPtEntry 4 } frEndPtPort OBJECT-TYPE SYNTAX INTEGER (1..64) ACCESS read-write -- C-ACCESS-FUNC FrEndPtPort -- C-LOCATOR-FUNC LocateFrEntry STATUS mandatory DESCRIPTION "Port Number. " ::= { frEndPtEntry 5 } frEndPtDlci OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write -- C-ACCESS-FUNC FrEndPtDlci -- C-LOCATOR-FUNC LocateFrEntry STATUS mandatory DESCRIPTION "DLCI." ::= { frEndPtEntry 6 } frEndPtConnIndex OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only -- C-ACCESS-FUNC FrEndPtConnIndex -- C-LOCATOR-FUNC LocateFrEntry STATUS mandatory DESCRIPTION "If the value of this object is greater than 0 then it is the index identifying the associated connectionEntry. Value 0 indicates dangling end point." ::= { frEndPtEntry 7 } frEndPtAdminStatus OBJECT-TYPE SYNTAX INTEGER { inactive(1), active(2), testing(3) } ACCESS read-write -- C-ACCESS-FUNC FrEndPtAdminStatus -- C-LOCATOR-FUNC LocateFrStatus STATUS mandatory DESCRIPTION " Administrative status of the end point." ::= { frEndPtEntry 8 } frEndPtOpStatus OBJECT-TYPE SYNTAX INTEGER { inactive(1), clear(2), fail(3), down(4), alarm(16) } ACCESS read-only -- C-ACCESS-FUNC FrEndPtOpStatus -- C-LOCATOR-FUNC LocateFrEntry STATUS mandatory DESCRIPTION " Operational Status of the end point. The value 'alarm' may only occur with and end point whose frEndPtCardType = 'frsm'. When frEndPtOpStatus has the value 'alarm' then either the slot, the line, or the port containing this endpoint has an alarm." ::= { frEndPtEntry 9 } frEndPtRowStatus OBJECT-TYPE SYNTAX INTEGER { active(1), createAndGo(4), destroy(6) } ACCESS read-write -- C-ACCESS-FUNC FrEndPtRowStatus -- C-LOCATOR-FUNC LocateFrEntry STATUS mandatory DESCRIPTION "The manager must set this to 'createAndGo' when creating a new entry. Other end point parameters also can be set in the same request. 'destroy' is only supported when the end point is not part of an end to end connection. setting the value to active will result in bad value." ::= { frEndPtEntry 10 } frEndPtMIR OBJECT-TYPE SYNTAX INTEGER (2400..2048000) ACCESS read-write -- C-ACCESS-FUNC FrEndPtMIR -- C-LOCATOR-FUNC LocateFrEntry STATUS mandatory DESCRIPTION "The minimum transmit bandwidth (MIR) parameter (in bits per second) for this end-point. This object has the relationship MIR <= CIR. This attribute can only be set to values evenly divisable by 100." DEFVAL { 9600 } ::= { frEndPtEntry 11 } frEndPtCIR OBJECT-TYPE SYNTAX INTEGER (2400..2048000) ACCESS read-write -- C-ACCESS-FUNC FrEndPtCIR -- C-LOCATOR-FUNC LocateFrEntry STATUS mandatory DESCRIPTION "The value of this object is equal to the committed information rate (CIR) parameter (in bits per second) for this end-point. This object holds the relationship MIR < = CIR <= QIR. This attribute can only be set to values evenly divisable by 100." DEFVAL { 9600 } ::= { frEndPtEntry 12 } frEndPtBc OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write -- C-ACCESS-FUNC FrEndPtBc -- C-LOCATOR-FUNC LocateFrEntry STATUS mandatory DESCRIPTION "The value of this object is equal to the committed burst size (Bc) parameter (in bytes) for this end-point. When frEndPtCardType is 'fr', this attribute is calculated as follows and should NOT be set: Bc = (VcQSize/(1 - MIR/port access rate)). When frEndPtCardType is 'frsm' the value is NOT calculated and is assigned the default value unless it is set." DEFVAL { 5100 } ::= { frEndPtEntry 13 } frEndPtBe OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write -- C-ACCESS-FUNC FrEndPtBe -- C-LOCATOR-FUNC LocateFrEntry STATUS mandatory DESCRIPTION "The value of this object is equal to the excess burst size (Be) parameter (in bytes) for this end-point. When frEndPtCardType is 'fr', this attribute is calculated as follows and should NOT be set: Be = Bc * (PIR/MIR - 1) When frEndPtCardType is 'frsm' the value is NOT calculated and is assigned the default value unless it is set." DEFVAL { 5100 } ::= { frEndPtEntry 14 } frEndPtVcQSize OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write -- C-ACCESS-FUNC FrEndPtVcQSize -- C-LOCATOR-FUNC LocateFrEntry STATUS mandatory DESCRIPTION "The value of this object is the maximum queue depth (in bytes) for this end-point." DEFVAL { 65535 } ::= { frEndPtEntry 15 } frEndPtPIR OBJECT-TYPE SYNTAX INTEGER (2400..2048000) ACCESS read-write -- C-ACCESS-FUNC FrEndPtPIR -- C-LOCATOR-FUNC LocateFrEntry STATUS mandatory DESCRIPTION "The peak transmit bandwidth (PIR) parameter (in bits per second) for this end-point. This attribute can only be set to values evenly divisable by 100." DEFVAL { 9600 } ::= { frEndPtEntry 16 } frEndPtCMAX OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write -- C-ACCESS-FUNC FrEndPtCMax -- C-LOCATOR-FUNC LocateFrEntry STATUS mandatory DESCRIPTION "The maximum credits that can be accrued for this end-point. This is not applicable for AXIS-frsm channels." DEFVAL { 10 } ::= { frEndPtEntry 17 } frEndPtEcnQSize OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write -- C-ACCESS-FUNC FrEndPtEcnQSize -- C-LOCATOR-FUNC LocateFrEntry STATUS mandatory DESCRIPTION "The threshold setting used by the explicit congestion notification feature for this end-point's transmit queue. This value is specified in bytes. When the frEndPtVcQSize value exceeds this value then the FECN bit will be set in all frames transmitted to the remote end-point." DEFVAL { 6553 } ::= { frEndPtEntry 18 } frEndPtQIR OBJECT-TYPE SYNTAX INTEGER (2400..2048000) ACCESS read-write -- C-ACCESS-FUNC FrEndPtQIR -- C-LOCATOR-FUNC LocateFrEntry STATUS mandatory DESCRIPTION "The transmit quiescent information rate (QIR) parameter (in bits per second) for this end-point. This value has the relationship CIR <= QIR <= PIR. This attribute can only be set to values evenly divisable by 100." DEFVAL { 9600 } ::= { frEndPtEntry 19 } frEndPtPercUtil OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-write -- C-ACCESS-FUNC FrEndPtPercUtil -- C-LOCATOR-FUNC LocateFrEntry STATUS mandatory DESCRIPTION "The value of this object is equal to the channel percentage utilization setting for this end-point. This is the expected long-term utilization of the channel by this end-point." DEFVAL { 100 } ::= { frEndPtEntry 20 } frEndPtPriority OBJECT-TYPE SYNTAX INTEGER { low(1), high(2) } ACCESS read-write -- C-ACCESS-FUNC FrEndPtPriority -- C-LOCATOR-FUNC LocateFrEntry STATUS mandatory DESCRIPTION "Priority for the Egress End. The value of this object determines the priority that is given to the data carried by this . If set to low, then the data is given the standard priority, and if set to high, the data will be given a higher priority. Higher priority data is placed at the beginning of the port's queues. NOTE: For a single segment connection(IPX-Routing to IPX-Routing), SET on frEndPtPriority is allowed for the local endpt only. i.e., SET on frEndPtPriority on the remote endpt is ignored. frEndPtPriority for the remote endpt gets the same value as that of the local endpt. This is not applicable for AXIS-frsm channels." DEFVAL { low } ::= { frEndPtEntry 21 } frEndPtInitialBurstSize OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write -- C-ACCESS-FUNC FrEndPtInitialBurstSize -- C-LOCATOR-FUNC LocateFrEntry STATUS mandatory DESCRIPTION "Initial burst size in bytes. Note that InitialBurstSize should be less than or equal to Bc. This is valid for frEndPtType of 'frsm'." DEFVAL { 5100 } ::= { frEndPtEntry 22 } frEndPtDeTagging OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write -- C-ACCESS-FUNC FrEndPtDeTagging -- C-LOCATOR-FUNC LocateFrEntry STATUS mandatory DESCRIPTION "Enable/disable DE tagging in the ingress direction only. This is valid for frEndPtType of 'frsm'." DEFVAL { disable } ::= { frEndPtEntry 23 } frEndPtIngressDeThreshold OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write -- C-ACCESS-FUNC FrEndPtDeThreshold -- C-LOCATOR-FUNC LocateFrEntry STATUS mandatory DESCRIPTION "Ingress threshold at which deletion occurs based on DE. This is valid for frEndPtType of 'frsm'." DEFVAL { 32768 } ::= { frEndPtEntry 24 } frEndPtEgressQDepth OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write -- C-ACCESS-FUNC FrEndPtEgressQDepth -- C-LOCATOR-FUNC LocateFrEntry STATUS mandatory DESCRIPTION "Egress Q Depth. This is valid for frEndPtType of 'frsm'." DEFVAL { 65535 } ::= { frEndPtEntry 25 } frEndPtEgressDeThreshold OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write -- C-ACCESS-FUNC FrEndPtEgressDeThreshold -- C-LOCATOR-FUNC LocateFrEntry STATUS mandatory DESCRIPTION "Egress threshold at which deletion occurs based on DE. This is valid for frEndPtType of 'frsm'." DEFVAL { 32768 } ::= { frEndPtEntry 26 } frEndPtEgressEcnThreshold OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write -- C-ACCESS-FUNC FrEndPtEgressEcnThreshold -- C-LOCATOR-FUNC LocateFrEntry STATUS mandatory DESCRIPTION "ECN threshold. This is valid for frEndPtType of 'frsm'." DEFVAL { 6553 } ::= { frEndPtEntry 27 } frEndPtEgressQSelect OBJECT-TYPE SYNTAX INTEGER { highPriority(1), lowPriority(2) } ACCESS read-write -- C-ACCESS-FUNC FrEndPtEgressQSelect -- C-LOCATOR-FUNC LocateFrEntry STATUS mandatory DESCRIPTION "Selects one out of two possible port queues. The default port queue number is 2 which is the low priority queue. This is only valid for frEndPtType of 'frsm'." ::= { frEndPtEntry 28 } frEndPtLpbkState OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only -- C-ACCESS-FUNC FrEndPtLpbkState -- C-LOCATOR-FUNC LocateFrStatus STATUS mandatory DESCRIPTION "The state of loopback mode for the end point. This is a bit mapped integer with the values defined as follows: local 1 remote 2 port 4 csu 8 dsu 16 external 32 testcon 64 " ::= { frEndPtEntry 29 } frEndPtType OBJECT-TYPE SYNTAX INTEGER { cdpSdpCard(1), fr(2), ait(3), frsm(4) } ACCESS read-only -- C-ACCESS-FUNC FrEndPtType -- C-LOCATOR-FUNC LocateFrEntry STATUS mandatory DESCRIPTION "Identifies a type of fr end point which some attributes may not apply. In particular the attributes frEndPtInitialBurstSize, frEndPtDeTagging frEndPtIngressDeThreshold, frEndPtEgressQDepth, frEndPtEgressDeThreshold, frEndPtEgressEcnThreshold and frEndPtEgressQSelect are valid only when frEndptType has the value 'frsm'. " ::= { frEndPtEntry 30 } frEndPtchanType OBJECT-TYPE SYNTAX INTEGER { frNIW(1), frSIW-transparent(2), frSIW-translate(3), frFUNI(4) } ACCESS read-write -- C-ACCESS-FUNC FrEndPtchanType -- C-LOCATOR-FUNC LocateFrEntry STATUS mandatory DESCRIPTION "(1) is frame-relay network interworking, (2) is service interworking with out any SDU translation, (3) is service interworking with SDU translation, and (4) is frame-relay UNI. This is only valid for frEndPtType of 'frsm'. Another restriction is that the other endpt should be an ASI(atmEndPtTable) endpt. If the other endpt is a FR endpt the DEFVAL will over-write the user's input." DEFVAL { frNIW } ::= { frEndPtEntry 31 } frEndPtchanFECNconfig OBJECT-TYPE SYNTAX INTEGER { mapEFCI(1), setEFCIzero(2) } ACCESS read-write -- C-ACCESS-FUNC FrEndPtFECNconfig -- C-LOCATOR-FUNC LocateFrEntry STATUS mandatory DESCRIPTION "The FECN bits in frame-relay are mapped to EFCI bit in the ATM cells. mapEFCI is valid only for SIW. This is only valid for frEndPtType of 'frsm'. Another restriction is that the other endpt should be an ASI(atmEndPtTable) endpt. If the other endpt is a FR endpt the DEFVAL will over-write the user's input." DEFVAL { setEFCIzero } ::= { frEndPtEntry 32 } frEndPtchanDEtoCLPmap OBJECT-TYPE SYNTAX INTEGER { mapCLP(1), setCLPzero(2), setCLPone(3) } ACCESS read-write -- C-ACCESS-FUNC FrEndPtDEtoCLPmap -- C-LOCATOR-FUNC LocateFrEntry STATUS mandatory DESCRIPTION "For (1), The DE bit is mapped to CLP bit in ATM cell. For (2) and (3), the DE bit is ignored and CLP bit is set to the constant value. This is only valid for frEndPtType of 'frsm'. Another restriction is that the other endpt should be an ASI(atmEndPtTable) endpt. If the other endpt is a FR endpt the DEFVAL will over-write the user's input." DEFVAL { mapCLP } ::= { frEndPtEntry 33 } frEndPtchanCLPtoDEmap OBJECT-TYPE SYNTAX INTEGER { mapDE(1), setDEzero(2), setDEone(3), ignoreCLP(4) } ACCESS read-write -- C-ACCESS-FUNC FrEndPtCLPtoDEmap -- C-LOCATOR-FUNC LocateFrEntry STATUS mandatory DESCRIPTION "Values (1), (2) and (3) are valid for SIW. Values (1) and (4) are valid for NIW. For (1), the CLP bit is mapped to DE bit in frame-relay. For (2) and (3), the CLP bit is ignored and DE bit is set to the constant value. ignoreCLP ignores CLP bit and DE bit remains as received. This is only valid for frEndPtType of 'frsm'. Another restriction is that the other endpt should be an ASI(atmEndPtTable) endpt. If the other endpt is a FR endpt the DEFVAL will over-write the user's input." DEFVAL { mapDE } ::= { frEndPtEntry 34 } -- -- The AIT end point table. -- -- An AIT end point is a gateway between Frame Relay and ATM. -- It is an ATM end point with the characteristics of Frame Relay. -- aitEndPtTable OBJECT-TYPE SYNTAX SEQUENCE OF AitEndPtEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A List of frame relay virtual circuit end points" ::= { connSvc 5 } aitEndPtEntry OBJECT-TYPE SYNTAX AitEndPtEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A frame relay end point Entry" INDEX { aitEndPtNodeName, aitEndPtIfShelf, aitEndPtSlot, aitEndPtVpi, aitEndPtVci } -- C-NEXT-FUNC NextAitEntry ::= { aitEndPtTable 1 } AitEndPtEntry ::= SEQUENCE { aitEndPtNodeName DisplayString, aitEndPtIfShelf DisplayString, aitEndPtSlot INTEGER, aitEndPtVpi INTEGER, aitEndPtVci INTEGER, aitEndPtConnIndex INTEGER, aitEndPtAdminStatus INTEGER, aitEndPtOpStatus INTEGER, aitEndPtMIR INTEGER, aitEndPtCIR INTEGER, aitEndPtVcQSize INTEGER, aitEndPtPIR INTEGER, aitEndPtCMAX INTEGER, aitEndPtEcnQSize INTEGER, aitEndPtQIR INTEGER, aitEndPtPercUtil INTEGER, aitEndPtPriority INTEGER } aitEndPtNodeName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..10)) ACCESS read-only -- C-ACCESS-FUNC FrEndPtNodeName -- C-LOCATOR-FUNC LocateAitEntry STATUS mandatory DESCRIPTION "The node name." ::= { aitEndPtEntry 1 } aitEndPtIfShelf OBJECT-TYPE SYNTAX DisplayString (SIZE(0..10)) ACCESS read-only -- C-ACCESS-FUNC FrEndPtIfShelf -- C-LOCATOR-FUNC LocateAitEntry STATUS mandatory DESCRIPTION "String identifying the shelf. This is a null string for end points which do not have a shelf name." ::= { aitEndPtEntry 2 } aitEndPtSlot OBJECT-TYPE SYNTAX INTEGER (1..64) ACCESS read-only -- C-ACCESS-FUNC FrEndPtSlot -- C-LOCATOR-FUNC LocateAitEntry STATUS mandatory DESCRIPTION "Slot Number." ::= { aitEndPtEntry 3 } aitEndPtVpi OBJECT-TYPE SYNTAX INTEGER (1..256) ACCESS read-only -- C-ACCESS-FUNC AitEndPtVpi -- C-LOCATOR-FUNC LocateAitEntry STATUS mandatory DESCRIPTION "VPI. " ::= { aitEndPtEntry 4 } aitEndPtVci OBJECT-TYPE SYNTAX INTEGER (1..512) ACCESS read-only -- C-ACCESS-FUNC AitEndPtVci -- C-LOCATOR-FUNC LocateAitEntry STATUS mandatory DESCRIPTION "VCI." ::= { aitEndPtEntry 5 } aitEndPtConnIndex OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only -- C-ACCESS-FUNC FrEndPtConnIndex -- C-LOCATOR-FUNC LocateAitEntry STATUS mandatory DESCRIPTION "If the value of this object is greater than 0 then it is the index identifying the associated connectionEntry." ::= { aitEndPtEntry 6 } aitEndPtAdminStatus OBJECT-TYPE SYNTAX INTEGER { inactive(1), active(2), testing(3) } ACCESS read-only -- C-ACCESS-FUNC FrEndPtAdminStatus -- C-LOCATOR-FUNC LocateAitEntry STATUS mandatory DESCRIPTION " Administrative status of the end point." ::= { aitEndPtEntry 7 } aitEndPtOpStatus OBJECT-TYPE SYNTAX INTEGER { inactive(1), clear(2), fail(3), down(4) } ACCESS read-only -- C-ACCESS-FUNC FrEndPtOpStatus -- C-LOCATOR-FUNC LocateAitEntry STATUS mandatory DESCRIPTION " Operational Status of the end point." ::= { aitEndPtEntry 8 } aitEndPtMIR OBJECT-TYPE SYNTAX INTEGER (2400..2048000) ACCESS read-only -- C-ACCESS-FUNC FrEndPtMIR -- C-LOCATOR-FUNC LocateAitEntry STATUS mandatory DESCRIPTION "The minimum transmit bandwidth (MIR) parameter (in bits per second) for this end-point. This object has the relationship MIR <= CIR. This attribute can only be set to values evenly divisable by 100." ::= { aitEndPtEntry 9 } aitEndPtCIR OBJECT-TYPE SYNTAX INTEGER (2400..2048000) ACCESS read-only -- C-ACCESS-FUNC FrEndPtCIR -- C-LOCATOR-FUNC LocateAitEntry STATUS mandatory DESCRIPTION "The value of this object is equal to the committed information rate (CIR) parameter (in bits per second) for this end-point. This object holds the relationship MIR < = CIR <= QIR. This attribute can only be set to values evenly divisable by 100." ::= { aitEndPtEntry 10 } aitEndPtVcQSize OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only -- C-ACCESS-FUNC FrEndPtVcQSize -- C-LOCATOR-FUNC LocateAitEntry STATUS mandatory DESCRIPTION "The value of this object is the maximum queue depth (in bytes) for this end-point. This object is required before row creation is complete." ::= { aitEndPtEntry 13 } aitEndPtPIR OBJECT-TYPE SYNTAX INTEGER (2400..2048000) ACCESS read-only -- C-ACCESS-FUNC FrEndPtPIR -- C-LOCATOR-FUNC LocateAitEntry STATUS mandatory DESCRIPTION "The peak transmit bandwidth (PIR) parameter (in bits per second) for this end-point. This attribute can only be set to values evenly divisable by 100." ::= { aitEndPtEntry 14 } aitEndPtCMAX OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only -- C-ACCESS-FUNC FrEndPtCMax -- C-LOCATOR-FUNC LocateAitEntry STATUS mandatory DESCRIPTION "The maximum credits that can be accrued for this end-point. This object is required before row creation is complete." ::= { aitEndPtEntry 15 } aitEndPtEcnQSize OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only -- C-ACCESS-FUNC FrEndPtEcnQSize -- C-LOCATOR-FUNC LocateAitEntry STATUS mandatory DESCRIPTION "The threshold setting used by the explicit congestion notification feature for this end-point's transmit queue. This value is specified in bytes. When the aitEndPtVcQSize value exceeds this value then the FECN bit will be set in all frames transmitted to the remote end-point. This object is required before row creation is complete." ::= { aitEndPtEntry 16 } aitEndPtQIR OBJECT-TYPE SYNTAX INTEGER (2400..2048000) ACCESS read-only -- C-ACCESS-FUNC FrEndPtQIR -- C-LOCATOR-FUNC LocateAitEntry STATUS mandatory DESCRIPTION "The transmit quiescent information rate (QIR) parameter (in bits per second) for this end-point. This value has the relationship CIR <= QIR <= PIR. This attribute can only be set to values evenly divisable by 100. " ::= { aitEndPtEntry 17 } aitEndPtPercUtil OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only -- C-ACCESS-FUNC FrEndPtPercUtil -- C-LOCATOR-FUNC LocateAitEntry STATUS mandatory DESCRIPTION "The value of this object is equal to the channel percentage utilization setting for this end-point. This is the expected long-term utilization of the channel by this end-point. This object is required before row creation is complete." ::= { aitEndPtEntry 18 } aitEndPtPriority OBJECT-TYPE SYNTAX INTEGER { low(1), high(2) } ACCESS read-only -- C-ACCESS-FUNC FrEndPtPriority -- C-LOCATOR-FUNC LocateAitEntry STATUS mandatory DESCRIPTION "connection priority." ::= { aitEndPtEntry 19 } -- -- This is the table describing an ATM connection end-point. -- Each connection (virtual circuit or ) end-point describes the -- particular characteristics of the end-point. Such information -- as bandwidth parameters are maintained in the end-point table. -- atmEndPtTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmEndPtEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The ATM End-Point table. This table is used to model a PVC end-point. This table contains the traffic parameters for ATM end-point." ::= { connSvc 6 } atmEndPtEntry OBJECT-TYPE SYNTAX AtmEndPtEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the ATM End-point table." INDEX { atmEndPtNodeName, atmEndPtIfShelf, atmEndPtSlot, atmEndPtPort, atmEndPtVpi, atmEndPtVci } -- C-NEXT-FUNC NextAtmEntry ::= { atmEndPtTable 1 } AtmEndPtEntry ::= SEQUENCE { atmEndPtNodeName DisplayString, atmEndPtIfShelf DisplayString, atmEndPtSlot INTEGER, atmEndPtPort INTEGER, atmEndPtVpi INTEGER, atmEndPtVci INTEGER, atmEndPtConnIndex INTEGER, atmEndPtAdminStatus INTEGER, atmEndPtOpStatus INTEGER, atmEndPtRowStatus INTEGER, atmEndPtCIR INTEGER, atmEndPtMIR INTEGER, atmEndPtPIR INTEGER, atmEndPtQIR INTEGER, atmEndPtPercUtil INTEGER, atmEndPtPriority INTEGER, atmEndPtIBS INTEGER, atmEndPtVcQSize INTEGER } atmEndPtNodeName OBJECT-TYPE SYNTAX DisplayString(SIZE(1..10)) ACCESS read-write -- C-ACCESS-FUNC atmEndPtNodeName -- C-LOCATOR-FUNC LocateAtmEntry STATUS mandatory DESCRIPTION "Node name of this endpoint." ::= { atmEndPtEntry 1 } atmEndPtIfShelf OBJECT-TYPE SYNTAX DisplayString(SIZE(0..10)) ACCESS read-write -- C-ACCESS-FUNC atmEndPtShelf -- C-LOCATOR-FUNC LocateAtmEntry STATUS mandatory DESCRIPTION "Shelf name of this endpoint. If no shelf name than this value is a NULL string." ::= { atmEndPtEntry 2 } atmEndPtSlot OBJECT-TYPE SYNTAX INTEGER (1..64) ACCESS read-write -- C-ACCESS-FUNC atmEndPtSlot -- C-LOCATOR-FUNC LocateAtmEntry STATUS mandatory DESCRIPTION "Local Slot Number." ::= { atmEndPtEntry 3 } atmEndPtPort OBJECT-TYPE SYNTAX INTEGER (1..64) ACCESS read-write -- C-ACCESS-FUNC atmEndPtPort -- C-LOCATOR-FUNC LocateAtmEntry STATUS mandatory DESCRIPTION "Local Port Number. These are numbered starting at 1." ::= { atmEndPtEntry 4 } atmEndPtVpi OBJECT-TYPE SYNTAX INTEGER (1..4095) ACCESS read-write -- C-ACCESS-FUNC atmEndPtVpi -- C-LOCATOR-FUNC LocateAtmEntry STATUS mandatory DESCRIPTION "Virtual port index." ::= { atmEndPtEntry 5 } atmEndPtVci OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write -- C-ACCESS-FUNC atmEndPtVci -- C-LOCATOR-FUNC LocateAtmEntry STATUS mandatory DESCRIPTION "virtual channel index." ::= { atmEndPtEntry 6 } atmEndPtConnIndex OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only -- C-ACCESS-FUNC atmEndPtConnIndex -- C-LOCATOR-FUNC LocateAtmEntry STATUS mandatory DESCRIPTION "If the value of this object is greater than 0 then it is the index identifying the associated connectionEntry." ::= { atmEndPtEntry 7 } atmEndPtAdminStatus OBJECT-TYPE SYNTAX INTEGER { inactive(1), active(2), testing(3) } ACCESS read-write -- C-ACCESS-FUNC atmEndPtAdminStatus -- C-LOCATOR-FUNC LocateAtmEntry STATUS mandatory DESCRIPTION "Admin Status of the end point." DEFVAL { inactive } ::= { atmEndPtEntry 9 } atmEndPtOpStatus OBJECT-TYPE SYNTAX INTEGER { inactive(1), clear(2), fail(3), down(4) } ACCESS read-only -- C-ACCESS-FUNC atmEndPtOpStatus -- C-LOCATOR-FUNC LocateAtmEntry STATUS mandatory DESCRIPTION "Operational Status of the end point." ::= { atmEndPtEntry 10 } atmEndPtRowStatus OBJECT-TYPE SYNTAX INTEGER { active(1), createAndGo(4), destroy(6) } ACCESS read-write -- C-ACCESS-FUNC atmEndPtRowStatus -- C-LOCATOR-FUNC LocateAtmEntry STATUS mandatory DESCRIPTION "The manager must set this to 'createAndGo' when creating a new entry. Other required elements can also be set in the same SET request" ::= { atmEndPtEntry 11 } atmEndPtMIR OBJECT-TYPE SYNTAX INTEGER (7..353208) ACCESS read-write -- C-ACCESS-FUNC atmEndPtMir -- C-LOCATOR-FUNC LocateAtmEntry STATUS mandatory DESCRIPTION "The minimum transmit bandwidth (MIR) parameter (in bits per second) for this end-point. For ATF without Foresight connections this object corresponds to the Peak Cell Rate(PCR) defined by ATM standard documents. For ATF with Foresight connections this object corresponds to the Minimum Cell Rate (MCR). (in bits per second) for this end-point. The maximum value for this object is the port speed of the associated interface." DEFVAL { 9600 } ::= { atmEndPtEntry 12 } atmEndPtCIR OBJECT-TYPE SYNTAX INTEGER (7..353208) ACCESS read-write -- C-ACCESS-FUNC atmEndPtCir -- C-LOCATOR-FUNC LocateAtmEntry STATUS mandatory DESCRIPTION "The value of this object is equal to the committed information rate (CIR) parameter (in bits per second) for this end-point. This object corresponds to the Sustainable Cell Rate(SCR) defined by ATM standard documents. The maximum value for this object is the port speed of the associated interface. All values between minimum and maximum for a given interface will be accepted, but they will be internally rounded up to the closest higher value valid for that interface." DEFVAL { 9600 } ::= { atmEndPtEntry 13 } atmEndPtPIR OBJECT-TYPE SYNTAX INTEGER (10..353208) ACCESS read-write -- C-ACCESS-FUNC atmEndPtPir -- C-LOCATOR-FUNC LocateAtmEntry STATUS mandatory DESCRIPTION "The peak transmit bandwidth (PIR) parameter (in bits per second) for this end-point. This object applies only to Foresight connections and corresponds to the Peak Cell Rate (PCR) defined by ATM standard documents. The maximum value for this object is the port speed of the associated interface." DEFVAL { 9600 } ::= { atmEndPtEntry 14 } atmEndPtQIR OBJECT-TYPE SYNTAX INTEGER (10..96000) ACCESS read-write -- C-ACCESS-FUNC atmEndPtQir -- C-LOCATOR-FUNC LocateAtmEntry STATUS mandatory DESCRIPTION "The transmit quiescent information rate (QIR) parameter (in bits per second) for this end-point. This parameter applies only to Foresight connections, and corresponds to the Initial Cell Rate (ICR) defined by ATM standard documents. This value can range between the MIR and PIR values." DEFVAL { 9600 } ::= { atmEndPtEntry 15 } atmEndPtPercUtil OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-write -- C-ACCESS-FUNC atmEndPtPercUtil -- C-LOCATOR-FUNC LocateAtmEntry STATUS mandatory DESCRIPTION "The value of this object is equal to the channel percentage utilization setting for this end-point. This is the expected long-term utilization of the channel by this end-point." DEFVAL { 100 } ::= { atmEndPtEntry 16 } atmEndPtPriority OBJECT-TYPE SYNTAX INTEGER { low(1), high(2) } ACCESS read-only -- C-ACCESS-FUNC atmEndPtPriority -- C-LOCATOR-FUNC LocateAtmEntry STATUS mandatory DESCRIPTION "queueing priority." ::= { atmEndPtEntry 17 } atmEndPtIBS OBJECT-TYPE SYNTAX INTEGER (1..24000) ACCESS read-write -- C-ACCESS-FUNC atmEndPtIBS -- C-LOCATOR-FUNC LocateAtmEntry STATUS mandatory DESCRIPTION "The value of this object is equal to the Initial Burst Size in cells for the other end-point. The maximum value for this object on OC3 end points is 1000." DEFVAL { 900 } ::= { atmEndPtEntry 18 } atmEndPtVcQSize OBJECT-TYPE SYNTAX INTEGER (1..64000) ACCESS read-write -- C-ACCESS-FUNC atmEndPtVcQSize -- C-LOCATOR-FUNC LocateAtmEntry STATUS mandatory DESCRIPTION "The value of this object is the maximum queue depth (in cells) for this end-point. For ATF without Foresight connections this object corresponds to the maximum Cell Delay Variation (CDV) Tolerance measured in cells." DEFVAL { 64000 } ::= { atmEndPtEntry 19 } -- -- The segment table identifies connection segments. It identifies the two end -- points of a connection which is not necessarily end to end. If the -- segment is part of a end to end connection, then the connectionEntry is -- identified as well as the local end point of the next segment. -- A 'local' end point may not be part of multiple segments. The table -- is indexed by the elements which identify the local end point of the -- segment, including the end point table. The other end point of the -- segment and an end point of the next segment are named by their -- object identifier. -- segmentTable OBJECT-TYPE SYNTAX SEQUENCE OF SegmentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A List of Connection Entries" ::= { connSvc 7 } segmentEntry OBJECT-TYPE SYNTAX SegmentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A generic end point Entry" INDEX { segEndPtTableId, segNodeName, segShelf, segSlot, segLine, segPort, segSubChn1, segSubChn2} -- C-NEXT-FUNC NextSegmentEntry ::= { segmentTable 1 } SegmentEntry ::= SEQUENCE { segEndPtTableId INTEGER, segNodeName DisplayString, segShelf DisplayString, segSlot INTEGER, segLine INTEGER, segPort INTEGER, segSubChn1 INTEGER, segSubChn2 INTEGER, segOeEndPt OBJECT IDENTIFIER, segConnIndex INTEGER, segNextSeg OBJECT IDENTIFIER } segEndPtTableId OBJECT-TYPE SYNTAX INTEGER { frEndPtTable(1), atmEndptTable(2) } ACCESS read-only -- C-ACCESS-FUNC segEndPtTableId -- C-LOCATOR-FUNC LocateSegEntry STATUS mandatory DESCRIPTION "The end point table from which the remaining indices are obtained." ::= { segmentEntry 1 } segNodeName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..10)) ACCESS read-only -- C-ACCESS-FUNC segNodeName -- C-LOCATOR-FUNC LocateSegEntry STATUS mandatory DESCRIPTION "The node name." ::= { segmentEntry 2 } segShelf OBJECT-TYPE SYNTAX DisplayString (SIZE(0..10)) ACCESS read-only -- C-ACCESS-FUNC segShelf -- C-LOCATOR-FUNC LocateSegEntry STATUS mandatory DESCRIPTION "String identifying the shelf. This is a null string for end points which do not have a shelf name." ::= { segmentEntry 3 } segSlot OBJECT-TYPE SYNTAX INTEGER (1..64) ACCESS read-only -- C-ACCESS-FUNC segSlot -- C-LOCATOR-FUNC LocateSegEntry STATUS mandatory DESCRIPTION "Slot Number." ::= { segmentEntry 4 } segLine OBJECT-TYPE SYNTAX INTEGER (0..8) ACCESS read-only -- C-ACCESS-FUNC segLine -- C-LOCATOR-FUNC LocateSegEntry STATUS mandatory DESCRIPTION "Line Number. If no line number is associated with the end point then this value is 0." ::= { segmentEntry 5 } segPort OBJECT-TYPE SYNTAX INTEGER (1..256) ACCESS read-only -- C-ACCESS-FUNC segPort -- C-LOCATOR-FUNC LocateSegEntry STATUS mandatory DESCRIPTION "Port Number. " ::= { segmentEntry 6 } segSubChn1 OBJECT-TYPE SYNTAX INTEGER (0..32767) ACCESS read-only -- C-ACCESS-FUNC segSubChn1 -- C-LOCATOR-FUNC LocateSegEntry STATUS mandatory DESCRIPTION "The meaning of this attribute is dependant on the value of segTableId. For 'frEndPtTable(1)' this value is the end point DLCI otherwise it is the end point VPI" ::= { segmentEntry 7 } segSubChn2 OBJECT-TYPE SYNTAX INTEGER (0..32767) ACCESS read-only -- C-ACCESS-FUNC segSubChn2 -- C-LOCATOR-FUNC LocateSegEntry STATUS mandatory DESCRIPTION "If the value of this attribute is 0, then it has no meaning in identifying the end point. If the value of this attribute is greater than 0 the it identifies the end point VCI." ::= { segmentEntry 8 } segOeEndPt OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only -- C-ACCESS-FUNC segOeEndPt -- C-LOCATOR-FUNC LocateSegEntry STATUS mandatory DESCRIPTION "The object id of the first attribute in the protocol specific end point table which is the 'remote' end point of the segment. If there is no remote end point then this attribute has the value of the NULL object identifier {0 0}." ::= { segmentEntry 9 } segConnIndex OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only -- C-ACCESS-FUNC segConnIndex -- C-LOCATOR-FUNC LocateSegEntry STATUS mandatory DESCRIPTION "The connectionIndex value identifying the end to end connection of which this segment is a part. If this value is 0, then the segment is not a part of any end to end connection." ::= { segmentEntry 10 } segNextSeg OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only -- C-ACCESS-FUNC segNextSeg -- C-LOCATOR-FUNC LocateSegEntry STATUS mandatory DESCRIPTION "The object id of the first attribute in the protocol specific end point table which is the 'local' end point of the next segment of the end to end connection identified by segConnIndex. A value of {0 0}, the NULL object identifier, indicates there is no next segment." ::= { segmentEntry 11 } ------------------------------------------------------------------ -- ERROR STATUS TABLE for Connections -- -- This object contains the value of the request id for the latest -- entry in the error status table. -- This value can be used to retrieve the error code and description -- for the last SET operation failed. -- cmpaErrorLastIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-ACCESS-FUNC ppaErrorLastIndex STATUS mandatory DESCRIPTION "If at least one entry exists in the error status table, the value of this object contains the index corresponding to the last entry inserted in the table. If no entries have ever been inserted in the cmpaErrorTable, then the agent will return 0 for a query of this variable. Actually this object is not required any more because of the new objects cmpaErrorLastDesc and cmpaErrorLastEcode. One can do GET directly on cmpaErrorLastDesc/LastEcode." ::= { connSvc 8 } cmpaErrorFlushAll OBJECT-TYPE SYNTAX INTEGER { noOp(1), flush(2) } ACCESS read-write -- C-ACCESS-FUNC ppaErrorFlushAll STATUS mandatory DESCRIPTION "Setting this object to the value 'flush' indicates to the agent that a manager would like the cmpaErrorTable to be immediately flushed of all entries. A management retrieval of this object will always return the value 'noOp'. Setting this object to the value 'noOp' is invalid." ::= { connSvc 9 } -- -- The following table is used to maintain status information about -- SNMP GET/SET requests from a Manager. When an SNMP GET/SET fails, an -- entry in this table is created and the object cmpaErrorLastIndex -- is updated. -- -- Note that currently only SET errors are updated in this error table. -- cmpaErrorTable OBJECT-TYPE SYNTAX SEQUENCE OF CmpaErrorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A List of recent Errors reported by the Ports Proxy Agent (PPA)." ::= { connSvc 10 } cmpaErrorEntry OBJECT-TYPE SYNTAX CmpaErrorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A General Error Status Entry." INDEX { cmpaErrorReqId } -- C-NEXT-FUNC NextErrorEntry ::= { cmpaErrorTable 1 } CmpaErrorEntry ::= SEQUENCE { cmpaErrorReqId INTEGER, cmpaErrorDesc DisplayString, cmpaErrorEcode INTEGER } cmpaErrorReqId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-ACCESS-FUNC ppaErrorReqId -- C-LOCATOR-FUNC LocateErrorEntry STATUS mandatory DESCRIPTION "This object contains the PDU request ID associated with the SET request. The manager must use this information to find the error associated with a particular SNMP request. Note that an SNMP request ID may be reused by the same manager. When this occurs, the older entry in the table will be replaced with the new error status. Managers must be aware that error information may therefore be lost." ::= { cmpaErrorEntry 1 } cmpaErrorDesc OBJECT-TYPE SYNTAX DisplayString (SIZE(1..255)) ACCESS read-only -- C-ACCESS-FUNC ppaErrorDesc -- C-LOCATOR-FUNC LocateErrorEntry STATUS mandatory DESCRIPTION "This object contains error status information for failed SETS to one or more objects in one or more of the following tables: frPortsCfgTable Rows in this table may be created as the result of a failed SNMP SET operation. Since the SNMP standard allows only limited number of error result codes, the managers can retrieve this variable to get additional information on a failed SET operation. Typically this object will contain a user friendly description of the cause of the error." ::= { cmpaErrorEntry 2 } cmpaErrorEcode OBJECT-TYPE SYNTAX INTEGER { invalid-network(1), -- No such Network(domain) in the Database invalid-node(2), -- No such Node in the Database invalid-shelf(3), -- No such Nhelf for the given node invalid-release(4), -- Unsupported release fot the given Node/Shelf node-timeout(5), -- Timeout from the given Node/Shelf node-busy(6), -- Node is busy processing other requests no-snmpcomm(7), -- The demon process snmpcomm is not running snmpcomm-error(8), -- Internal error at the demon process snmpcomm node-error(9), -- Error at the embedded Agent bad-value(10), -- Bad value for the given Object port-not-found(11), -- The specified port does not exists slot-is-full(12), -- AddConn error, no more conns on this slot conn-not-found(100), -- The specified connection does not exists endpt-exists(101), -- AddConn error, Endpt already exists lendpt-exists(102), -- AddConn error, Local Endpt already exists rendpt-exists(103), -- AddConn error, Remote Endpt already exists lendpt-missing(104), -- connectionLocalEndPt is missing from the SET request rendpt-missing(105), -- connectionRemoteEndPt is missing from the SET request db-lendpt-not-found(106), -- Could not find Local Endpt in Database db-rendpt-not-found(107), -- Could not find Remote Endpt in Database lendpt-not-found(108), -- connectionLocalEndPt specified does not exists rendpt-not-found(109), -- connectionRemoteEndPt specified does not exists dangling-endpt(110), -- The Endpt is part of an incomplete connection endpt-rowstatus-missing(111), -- frEndPtRowStatus is missing from the SET request conn-rowstatus-missing(112), -- connectionRowStatus is missing from the SET request invalid-endpt-rowstatus(113), -- End point RowStatus can not be set to Active invalid-conn-rowstatus(114), -- connectionRowStatus can not be set to Active invalid-connindex(115), -- Invalid connection Index used for AddConn testtype-missing(116), -- connectionTestType is missing from the SET Request partial-add(117), -- Connection is added, but modification failed partial-mod(118), -- Endpt is modified, but connection params not modified invalid-bw(119), -- Invalid BandWidth param relationship. not-active(120), -- Connection is not in active state invalid-adminstatus(121), -- connectionAdminStatus can be SET to testing only not-clear(122), -- connectionOpStatus is not in clear state invalid-endpt-comb(123), -- Invalid Endpt combination for the connection invalid-chantype(124), -- Invalid chanType for the given Endpt combination cmgrd-timeout(125), -- No response from the demon cmgrd no-cmgrd(126), -- The demon cmgrd is not running ronly-for-frp(127), -- Object is read-only for FRP(IPX) Endpt invalid-chanFECNconfig(128), -- Invalid chanFECNconfig for the given chanType invalid-chanCLPtoDEmap(129), -- Invalid chanCLPtoDEmap for the given chanType ibs-less-bc(130), -- InitialBurstSize(IBS) should be less than or equal to Bc asi-no-remote(131), -- ASI can not be used as a remote End point frsm-remote(132), -- Remote End point must be FRSM for ASI connections foresight-disabled(133), -- PIR, MIR and QIR can not be Modified for AXIS endpt, -- when Foresight is disabled no-error-entry(500), -- No entries available in the ErrorTable not-applicable(501), -- Error Code not relevant, rely on Error Description invalid-flushall(502) -- Can not set to noOp for cmpaErrorFlushAll } ACCESS read-only -- C-ACCESS-FUNC ppaErrorEcode -- C-LOCATOR-FUNC LocateErrorEntry STATUS mandatory DESCRIPTION "This object contains the error Code of the GET/SET operation. The error Codes from 500 onwards are specific to the Error Table operation itself. Note that currently GET errors are not updated in the error table." ::= { cmpaErrorEntry 3 } cmpaErrorLastDesc OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) ACCESS read-only -- C-ACCESS-FUNC ppaErrorLastDesc STATUS mandatory DESCRIPTION "This contains the error description of the last error generated. If error table contains no errors, GET on this will return NULL string" ::= { connSvc 11 } cmpaErrorLastEcode OBJECT-TYPE SYNTAX INTEGER { invalid-network(1), -- No such Network(domain) in the Database invalid-node(2), -- No such Node in the Database invalid-shelf(3), -- No such Nhelf for the given node invalid-release(4), -- Unsupported release fot the given Node/Shelf node-timeout(5), -- Timeout from the given Node/Shelf node-busy(6), -- Node is busy processing other requests no-snmpcomm(7), -- The demon process snmpcomm is not running snmpcomm-error(8), -- Internal error at the demon process snmpcomm node-error(9), -- Error at the embedded Agent bad-value(10), -- Bad value for the given Object port-not-found(11), -- The specified port does not exists slot-is-full(12), -- AddConn error, no more conns on this slot conn-not-found(100), -- The specified connection does not exists endpt-exists(101), -- AddConn error, Endpt already exists lendpt-exists(102), -- AddConn error, Local Endpt already exists rendpt-exists(103), -- AddConn error, Remote Endpt already exists lendpt-missing(104), -- connectionLocalEndPt is missing from the SET request rendpt-missing(105), -- connectionRemoteEndPt is missing from the SET request db-lendpt-not-found(106), -- Could not find Local Endpt in Database db-rendpt-not-found(107), -- Could not find Remote Endpt in Database lendpt-not-found(108), -- connectionLocalEndPt specified does not exists rendpt-not-found(109), -- connectionRemoteEndPt specified does not exists dangling-endpt(110), -- The Endpt is part of an incomplete connection endpt-rowstatus-missing(111), -- frEndPtRowStatus is missing from the SET request conn-rowstatus-missing(112), -- connectionRowStatus is missing from the SET request invalid-endpt-rowstatus(113), -- End point RowStatus can not be set to Active invalid-conn-rowstatus(114), -- connectionRowStatus can not be set to Active invalid-connindex(115), -- Invalid connection Index used for AddConn testtype-missing(116), -- connectionTestType is missing from the SET Request partial-add(117), -- Connection is added, but modification failed partial-mod(118), -- Endpt is modified, but connection params not modified invalid-bw(119), -- Invalid BandWidth param relationship. not-active(120), -- Connection is not in active state invalid-adminstatus(121), -- connectionAdminStatus can be SET to testing only not-clear(122), -- connectionOpStatus is not in clear state invalid-endpt-comb(123), -- Invalid Endpt combination for the connection invalid-chantype(124), -- Invalid chanType for the given Endpt combination cmgrd-timeout(125), -- No response from the demon cmgrd no-cmgrd(126), -- The demon cmgrd is not running ronly-for-frp(127), -- Object is read-only for FRP(IPX) Endpt invalid-chanFECNconfig(128), -- Invalid chanFECNconfig for the given chanType invalid-chanCLPtoDEmap(129), -- Invalid chanCLPtoDEmap for the given chanType ibs-less-bc(130), -- InitialBurstSize(IBS) should be less than or equal to Bc asi-no-remote(131), -- ASI can not be used as a remote End point frsm-remote(132), -- Remote End point must be FRSM for ASI connections foresight-disabled(133), -- PIR, MIR and QIR can not be Modified for AXIS endpt, -- when Foresight is disabled no-error-entry(500), -- No entries available in the ErrorTable not-applicable(501), -- Error Code not relevant, rely on Error Description invalid-flushall(502) -- Can not set to noOp for cmpaErrorFlushAll } ACCESS read-only -- C-ACCESS-FUNC ppaErrorLastEcode STATUS mandatory DESCRIPTION "This contains the error code of the last error generated. If error table contains no errors, GET on this object returns 500" ::= { connSvc 12 } -- portSvc MIB defines tables and attributes for maintaining -- fr ports for AXIS and IPX through system manager interface. -- It also gives information on the configuration state of the ports -- The following Table portsInfoTable gives the information on the -- configuration state of the ports portsInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF PortsInfoEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Ports information for the specified line" ::= { portSvc 1 } portsInfoEntry OBJECT-TYPE SYNTAX PortsInfoEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Ports Information Entry" INDEX { portsInfoNode, portsInfoShelf, portsInfoSlot, portsInfoLine, portsInfoPort } -- C-NEXT-FUNC NextPortsEntry ::= { portsInfoTable 1 } PortsInfoEntry ::= SEQUENCE { portsInfoNode DisplayString, portsInfoShelf DisplayString, portsInfoSlot INTEGER, portsInfoLine INTEGER, portsInfoPort INTEGER, portsInfoPortType INTEGER, portsInfoPortState INTEGER, portsInfoPortSpeed INTEGER } portsInfoNode OBJECT-TYPE SYNTAX DisplayString (SIZE(1..10)) ACCESS read-only -- C-ACCESS-FUNC PortsInfoNode -- C-LOCATOR-FUNC LocatePortsInfoEntry STATUS mandatory DESCRIPTION "String identifying the node" ::= { portsInfoEntry 1 } portsInfoShelf OBJECT-TYPE SYNTAX DisplayString (SIZE(0..10)) ACCESS read-only -- C-ACCESS-FUNC PortsInfoShelf -- C-LOCATOR-FUNC LocatePortsInfoEntry STATUS mandatory DESCRIPTION "String identifying the shelf" ::= { portsInfoEntry 2 } portsInfoSlot OBJECT-TYPE SYNTAX INTEGER (1..64) ACCESS read-only -- C-ACCESS-FUNC PortsInfoSlot -- C-LOCATOR-FUNC LocatePortsInfoEntry STATUS mandatory DESCRIPTION "Slot Number" ::= { portsInfoEntry 3 } portsInfoLine OBJECT-TYPE SYNTAX INTEGER (0..8) ACCESS read-only -- C-ACCESS-FUNC PortsInfoLine -- C-LOCATOR-FUNC LocatePortsInfoEntry STATUS mandatory DESCRIPTION "Line Number. For IPX ports Line Number is always 0" ::= { portsInfoEntry 4 } portsInfoPort OBJECT-TYPE SYNTAX INTEGER (1..64) ACCESS read-only -- C-ACCESS-FUNC PortsInfoPort -- C-LOCATOR-FUNC LocatePortsInfoEntry STATUS mandatory DESCRIPTION "Port Number" ::= { portsInfoEntry 5 } portsInfoPortType OBJECT-TYPE SYNTAX INTEGER { frsm(1), frp (2), ausm(3), atm (4) } ACCESS read-only -- C-ACCESS-FUNC PortsInfoPortType -- C-LOCATOR-FUNC LocatePortsInfoEntry STATUS mandatory DESCRIPTION "Port type includes Card type as well as Interface type" ::= { portsInfoEntry 6 } portsInfoPortState OBJECT-TYPE SYNTAX INTEGER { active(1), inactive(2), remoteLoopback(3), failed(4) } ACCESS read-only -- C-ACCESS-FUNC PortsInfoPortState -- C-LOCATOR-FUNC LocatePortsInfoEntry STATUS mandatory DESCRIPTION "Port state" ::= { portsInfoEntry 7 } portsInfoPortSpeed OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-ACCESS-FUNC PortsInfoPortSpeed -- C-LOCATOR-FUNC LocatePortsInfoEntry STATUS mandatory DESCRIPTION "Configured speed of port in kbps" ::= { portsInfoEntry 8 } -- The following table is used for maintaining -- fr ports for AXIS and IPX through system manager interface. -- Note that the objects with 'frPorts' suffix belong to both -- AXIS and IPX nodes. Objects with 'frAxPorts' are specific -- to AXIS nodes and objects with 'frIxPorts' are specific to IPX. -- For AXIS we can add, delete and modify the ports. -- Fox IPX we can also up and down the ports, in addition -- to add, delete and modify. frPortsCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF FrPortsCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "fr ports updations for AXIS and IPX." ::= { portSvc 2 } frPortsCfgEntry OBJECT-TYPE SYNTAX FrPortsCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Ports Cfgrmation Entry" INDEX { frPortsCfgNode, frPortsCfgShelf, frPortsCfgSlot, frPortsCfgLine, frPortsCfgPort} -- C-NEXT-FUNC NextPortsEntry ::= { frPortsCfgTable 1 } FrPortsCfgEntry ::= SEQUENCE { frPortsCfgNode DisplayString, frPortsCfgShelf DisplayString, frPortsCfgSlot INTEGER, frPortsCfgLine INTEGER, frPortsCfgPort INTEGER, frPortsCfgRowStatus INTEGER, frPortsCfgPortType INTEGER, frPortsCfgPortState INTEGER, frPortsCfgChCnt INTEGER, frPortsCfgPortSpeed INTEGER, frPortsCfgDs0ChSpeed INTEGER, frPortsCfgSigProt INTEGER, frPortsCfgNNIStatus INTEGER, frPortsCfgAsyncUpd INTEGER, frPortsCfgPollVerTimer INTEGER, frPortsCfgErrThresh INTEGER, frPortsCfgMonEveCnt INTEGER, frPortsCfgFrmFlags INTEGER, frPortsCfgLinkTimer INTEGER, frPortsCfgPollCycle INTEGER, frAxPortsCfgSvcRatio INTEGER, frIxPortsCfgClockType INTEGER, frIxPortsCfgVcCount INTEGER, frPortsCfgVcPtr OBJECT IDENTIFIER, frIxPortsCfgMaxTxQDepth INTEGER, frIxPortsCfgECNQThresh INTEGER, frIxPortsCfgDEThresh INTEGER, frIxPortsCfgIDEMap INTEGER, frIxPortsCfgCommPri INTEGER, frIxPortsCfgUpRNR INTEGER, frIxPortsCfgLowRNR INTEGER, frIxPortsCfgOamThresh INTEGER, frIxPortsCfgCLLMTimer INTEGER, frIxPortsCfgEFCItoBECN INTEGER, frIxPortsCfgSrRTS INTEGER, frIxPortsCfgSrDTR INTEGER, frIxPortsCfgSrDCD INTEGER, frIxPortsCfgSrCTS INTEGER, frIxPortsCfgSrDSR INTEGER, frIxPortsCfgLoopBack INTEGER, frIxPortsCfgExtConFail INTEGER, frAxPortsCfgLogPort INTEGER } frPortsCfgNode OBJECT-TYPE SYNTAX DisplayString (SIZE(1..10)) ACCESS read-only -- C-ACCESS-FUNC FrPortsCfgNode -- C-LOCATOR-FUNC LocateFrPortsCfgEntry STATUS mandatory DESCRIPTION "String identifying the Node" ::= { frPortsCfgEntry 1 } frPortsCfgShelf OBJECT-TYPE SYNTAX DisplayString (SIZE(0..10)) ACCESS read-only -- C-ACCESS-FUNC FrPortsCfgShelf -- C-LOCATOR-FUNC LocateFrPortsCfgEntry STATUS mandatory DESCRIPTION "String identifying the shelf" ::= { frPortsCfgEntry 2 } frPortsCfgSlot OBJECT-TYPE SYNTAX INTEGER (1..64) ACCESS read-only -- C-ACCESS-FUNC FrPortsCfgSlot -- C-LOCATOR-FUNC LocateFrPortsCfgEntry STATUS mandatory DESCRIPTION "Slot Number" ::= { frPortsCfgEntry 3 } frPortsCfgLine OBJECT-TYPE SYNTAX INTEGER (0..8) ACCESS read-only -- C-ACCESS-FUNC FrPortsCfgLine -- C-LOCATOR-FUNC LocateFrPortsCfgEntry STATUS mandatory DESCRIPTION "Line Number. For IPX ports Line Number is always 0" ::= { frPortsCfgEntry 4 } frPortsCfgPort OBJECT-TYPE SYNTAX INTEGER (1..64) ACCESS read-only -- C-ACCESS-FUNC FrPortsCfgPort -- C-LOCATOR-FUNC LocateFrPortsCfgEntry STATUS mandatory DESCRIPTION "Port Number" ::= { frPortsCfgEntry 5 } frPortsCfgRowStatus OBJECT-TYPE SYNTAX INTEGER { add(1), del(2), modify(3), up-frp(4), down-frp(5) } ACCESS read-write -- C-ACCESS-FUNC FrPortsCfgRowStatus -- C-LOCATOR-FUNC LocateFrPortsCfgEntry STATUS mandatory DESCRIPTION "add, del & modify are for both AXIS and IPX ports, but up and down are for IPX only" ::= { frPortsCfgEntry 6 } frPortsCfgPortType OBJECT-TYPE SYNTAX INTEGER { frsm(1), frp (2) } ACCESS read-only -- C-ACCESS-FUNC FrPortsCfgPortType -- C-LOCATOR-FUNC LocateFrPortsCfgEntry STATUS mandatory DESCRIPTION "Card type, FRP or FRSM" ::= { frPortsCfgEntry 7 } frPortsCfgPortState OBJECT-TYPE SYNTAX INTEGER { active(1), inactive(2), remoteLoopback(3), failed(4) } ACCESS read-only -- C-ACCESS-FUNC FrPortsCfgPortState -- C-LOCATOR-FUNC LocateFrPortsCfgEntry STATUS mandatory DESCRIPTION "PortState" ::= { frPortsCfgEntry 8 } frPortsCfgChCnt OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-ACCESS-FUNC FrPortsCfgChCnt -- C-LOCATOR-FUNC LocateFrPortsCfgEntry STATUS mandatory DESCRIPTION "The number of aggregate channels assigned to this port (FRI T1/E1 interface only). For subrate ports, this object is always 1." ::= { frPortsCfgEntry 9 } frPortsCfgPortSpeed OBJECT-TYPE SYNTAX INTEGER ACCESS read-write -- C-ACCESS-FUNC FrPortsCfgPortSpeed -- C-LOCATOR-FUNC LocateFrPortsCfgEntry STATUS mandatory DESCRIPTION "Configured speed of port in kbps. - Set operation: For subrate(V.35) interface only. For E1/T1, you can set only while adding the port" ::= { frPortsCfgEntry 10 } frPortsCfgDs0ChSpeed OBJECT-TYPE SYNTAX INTEGER { s56k(1), s64k(2), na(3) } ACCESS read-write -- C-ACCESS-FUNC FrPortsCfgDs0ChSpeed -- C-LOCATOR-FUNC LocateFrPortsCfgEntry STATUS mandatory DESCRIPTION "channel speed. This is not applicable for FRP-V35 subrate ports. Set operation: - Allowed only while adding the port." ::= { frPortsCfgEntry 11 } frPortsCfgSigProt OBJECT-TYPE SYNTAX INTEGER { disabled (1), lmi-noasyn (2), lmi-asyn (3), uni-annexA (4), uni-annexD (5), nni-annexA (6), nni-annexD (7) } ACCESS read-write -- C-ACCESS-FUNC FrPortsCfgSigProt -- C-LOCATOR-FUNC LocateFrPortsCfgEntry STATUS mandatory DESCRIPTION "The specified LMI operation mode. The options can be 1 - (UNI)LMI disabled 2 - (UNI)LMI enabled but asynchronous update disabled 3 - (UNI)LMI and asynchronous update enabled 4 - (UNI)LMI enabled using CCITT O.933 Annex A parameters 5 - (UNI)LMI enabled using ANSI T1.617 parameters 6 - (NNI)LMI enabled using CCITT O.933 Annex A parameters 7 - (NNI)LMI enabled using ANSI T1.617 parameters" ::= { frPortsCfgEntry 12 } frPortsCfgNNIStatus OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-only -- C-ACCESS-FUNC FrPortsCfgNNIStatus -- C-LOCATOR-FUNC LocateFrPortsCfgEntry STATUS mandatory DESCRIPTION "The flag indicating whether NNI is active on the specified slot.port. - Get Operation: This object is always NO if the network manager attempts to GET frLportNNIStatus from a disabled or LMI port. In other cases, the value of this object is determined by whether the port is configured as NNI or not." ::= { frPortsCfgEntry 13 } frPortsCfgAsyncUpd OBJECT-TYPE SYNTAX INTEGER { no(1), yes(2) } ACCESS read-write -- C-ACCESS-FUNC FrPortsCfgAsyncUpd -- C-LOCATOR-FUNC LocateFrPortsCfgEntry STATUS mandatory DESCRIPTION "The flag indicating whether the IPX should send unsolicited LMI update messages as they appear or wait for the polling from the user device. This object is applicable to only Annex A/D UNI and Annex A/D NNI protocols for write and LMI, Annex A/D UNI and Annex A/D NNI for read. - Get Operation: This object is always NO for ports without protocols; otherwise, its value is determined by the asynchronous status of the port. - Set Operation: If the network manager attempts to SET this object of a port with none or LMI protocol, an error is reported." ::= { frPortsCfgEntry 14 } frPortsCfgPollVerTimer OBJECT-TYPE SYNTAX INTEGER ACCESS read-write -- C-ACCESS-FUNC FrPortsCfgPollVerTimer -- C-LOCATOR-FUNC LocateFrPortsCfgEntry STATUS mandatory DESCRIPTION "The link integrity verification timer heartbeat (keep-alive) period. It should be set to 5 seconds more than the heartbeat time in the user device. The valid range is (5..30) - Get Operation: Since this object is not applicable to disabled protocol, (-1) is returned if the network manager attempts to GET this object from a port without protocols. - Set Operation: If the network manager attempts to SET this object of a port without any protocol, an error is reported." DEFVAL { 15 } ::= { frPortsCfgEntry 15 } frPortsCfgErrThresh OBJECT-TYPE SYNTAX INTEGER ACCESS read-write -- C-ACCESS-FUNC FrPortsCfgErrThresh -- C-LOCATOR-FUNC LocateFrPortsCfgEntry STATUS mandatory DESCRIPTION "The number of the failures in the monitored events that cause the keep-alive process to report an alarm. The valid range is (1..10). - Get Operation: Since this object is not applicable to disabled protocol, (-1) is returned if the network manager attempts to GET this object from a port without protocols. - Set Operation: If the network manager attempts to SET this object of a port without any protocol, an error is reported." ::= { frPortsCfgEntry 16 } frPortsCfgMonEveCnt OBJECT-TYPE SYNTAX INTEGER ACCESS read-write -- C-ACCESS-FUNC FrPortsCfgMonEveCnt -- C-LOCATOR-FUNC LocateFrPortsCfgEntry STATUS mandatory DESCRIPTION "The number of monitored events for the keep-alive process. A port communication fail condition is cleared after this number of successful polling cycles. The valid range is (1..10) - Get Operation: Since this object is not applicable to disabled protocol, (-1) is returned if the network manager attempts to GET this object from a port without protocols. - Set Operation: If the network manager attempts to SET this object of a port without any protocol, an error is reported." ::= { frPortsCfgEntry 17 } frPortsCfgFrmFlags OBJECT-TYPE SYNTAX INTEGER ACCESS read-write -- C-ACCESS-FUNC FrPortsCfgFrmFlags -- C-LOCATOR-FUNC LocateFrPortsCfgEntry STATUS mandatory DESCRIPTION "The minimum number of flags between frames. The valid range for AXIS-FRSM ports is (1..10) The valid range for IPX-FRP ports is (1..255)" DEFVAL { 1 } ::= { frPortsCfgEntry 18 } frPortsCfgLinkTimer OBJECT-TYPE SYNTAX INTEGER ACCESS read-write -- C-ACCESS-FUNC FrPortsCfgLinkTimer -- C-LOCATOR-FUNC LocateFrPortsCfgEntry STATUS mandatory DESCRIPTION "T391 - Link Integrity Timer (applicable to NNI port only), indicating the interval at which a Status Enquiry message is sent. The valid range is (5..30) - Get Operation: the network manager attempts to GET this object from a port with a protocol other than NNIs, (-1) is returned. - Set Operation: If the network manager attempts to SET this object of a port with a protocol other than NNIs, an error is reported" DEFVAL { 10 } ::= { frPortsCfgEntry 19 } frPortsCfgPollCycle OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write -- C-ACCESS-FUNC FrPortsCfgPollCycle -- C-LOCATOR-FUNC LocateFrPortsCfgEntry STATUS mandatory DESCRIPTION "N391 - Full Status Polling Cycle. Applicable to NNI ports only in case of IPX frp. - Get Operation(for IPX-frp): If the network manager attempts to GET this object from a port with a protocol other than NNIs, (-1) is returned. - Set Operation(for IPX-frp): If the network manager attempts to SET this object of a port with a protocol other than NNIs, an error is reported." ::= { frPortsCfgEntry 20 } frAxPortsCfgSvcRatio OBJECT-TYPE SYNTAX INTEGER ACCESS read-write -- C-ACCESS-FUNC FrPortsCfgSvcRatio -- C-LOCATOR-FUNC LocateFrPortsCfgEntry STATUS mandatory DESCRIPTION "Number of times queue 2 is serviced for every time queue 3 is serviced The valid range is (1..15). Only applicable to AXIS-FRSM ports. The value (-2) will be returned for IPX-FRP ports." DEFVAL { 1 } ::= { frPortsCfgEntry 21 } frIxPortsCfgClockType OBJECT-TYPE SYNTAX INTEGER { normal (1), looped (2), none (3) } ACCESS read-write -- C-ACCESS-FUNC FrPortsCfgClockType -- C-LOCATOR-FUNC LocateFrPortsCfgEntry STATUS mandatory DESCRIPTION "The type of port clock (FRI subrate interface only). For T1/E1 interface this object should be none. - Get Operation: If the network manager attempts to get this object from a T1/E1 port, none(3) is returned. - Set Operation: If the network manager attempts to set this object on a T1/E1 port an error is returned. Only applicable to IPX-FRP ports. The value (-2) will be returned for AXIS-FRSM ports." ::= { frPortsCfgEntry 22 } frIxPortsCfgVcCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-ACCESS-FUNC FrPortsCfgVcCount -- C-LOCATOR-FUNC LocateFrPortsCfgEntry STATUS mandatory DESCRIPTION "The number of virtual connections that terminate on this port. Note that there can be up to 252 connections per FRP cards shared among the ports. A port may have up to 252 connections allocated. The valid range is (0..252). Only applicable to IPX-FRP ports. The value (-2) will be returned for AXIS-FRSM ports." ::= { frPortsCfgEntry 23 } frPortsCfgVcPtr OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only -- C-ACCESS-FUNC FrPortsCfgVcPtr -- C-LOCATOR-FUNC LocateFrPortsCfgEntry STATUS mandatory DESCRIPTION "The object identifier denoting the first endpoint associated with this port. For current implementation, this OID points to the first frame relay connection on the port. It has a NULL OID value (i.e. { 0 0 }) if there is no frame relay connection on this port. The management station can retrieve all the information about the first connection by reading from row pointed to by this OID. Specifically, this OID specifies the first column of the appropriate row in the frEndptTable." ::= { frPortsCfgEntry 24 } frIxPortsCfgMaxTxQDepth OBJECT-TYPE SYNTAX INTEGER ACCESS read-write -- C-ACCESS-FUNC FrPortsCfgMaxTxQDepth -- C-LOCATOR-FUNC LocateFrPortsCfgEntry STATUS mandatory DESCRIPTION "The maximum bytes queued for transmission from the FRP port. The valid range is (0..65535). Only applicable to IPX-FRP ports. The value (-2) will be returned for AXIS-FRSM ports." DEFVAL { 65535 } ::= { frPortsCfgEntry 25 } frIxPortsCfgECNQThresh OBJECT-TYPE SYNTAX INTEGER ACCESS read-write -- C-ACCESS-FUNC FrPortsCfgECNQThresh -- C-LOCATOR-FUNC LocateFrPortsCfgEntry STATUS mandatory DESCRIPTION "Port explicit congestion notification threshold. This is the point at which the BECN and FECN bits will be set in the communications to the user device. The valid range is (0..65535). Only applicable to IPX-FRP ports. The value (-2) will be returned for AXIS-FRSM ports." DEFVAL { 65535 } ::= { frPortsCfgEntry 26 } frIxPortsCfgDEThresh OBJECT-TYPE SYNTAX INTEGER ACCESS read-write -- C-ACCESS-FUNC FrPortsCfgDEThresh -- C-LOCATOR-FUNC LocateFrPortsCfgEntry STATUS mandatory DESCRIPTION "The percentage of the queue depth above which frames with the Discard Eligibility bit set will be discarded. An entry of 100% effectively disables DE for the port. The valid range is (0..100) Only applicable to IPX-FRP ports. The value (-2) will be returned for AXIS-FRSM ports." DEFVAL { 100 } ::= { frPortsCfgEntry 27 } frIxPortsCfgIDEMap OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write -- C-ACCESS-FUNC FrPortsCfgIDEMap -- C-LOCATOR-FUNC LocateFrPortsCfgEntry STATUS mandatory DESCRIPTION "The flag indicating whether IDE to DE mapping should be performed. Only applicable to IPX-FRP ports. The value (-2) will be returned for AXIS-FRSM ports." DEFVAL { yes } ::= { frPortsCfgEntry 28 } frIxPortsCfgCommPri OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write -- C-ACCESS-FUNC FrPortsCfgCommPri -- C-LOCATOR-FUNC LocateFrPortsCfgEntry STATUS mandatory DESCRIPTION "The flag specifying if the connection SNA priority should be communicated to the user device attached to the port. - Get Operation: Since this object is specific to LMI protocols, (-1) is returned if the network manager attempts to GET this object from a non-LMI port. - Set Operation: Likewise, if the network manager attempts to SET this object of a non-LMI port, an error is reported. Only applicable to IPX-FRP ports. The value (-2) will be returned for AXIS-FRSM ports." ::= { frPortsCfgEntry 29 } frIxPortsCfgUpRNR OBJECT-TYPE SYNTAX INTEGER ACCESS read-write -- C-ACCESS-FUNC FrPortsCfgUpRNR -- C-LOCATOR-FUNC LocateFrPortsCfgEntry STATUS mandatory DESCRIPTION "The upper Receiver-Not-Ready threshold. This threshold specifies the number of receiver not ready indications from the user equipment before an alarm is generated for this connection. The valid range is (1..100) - Get Operation: Since this object is specific to LMI protocols, (-1) is returned if the network manager attempts to GET this object from a non-LMI port. - Set Operation: Likewise, if the network manager attempts to SET this object of a non-LMI port, an error is reported. Only applicable to IPX-FRP ports. The value (-2) will be returned for AXIS-FRSM ports." DEFVAL { 75 } ::= { frPortsCfgEntry 30 } frIxPortsCfgLowRNR OBJECT-TYPE SYNTAX INTEGER ACCESS read-write -- C-ACCESS-FUNC FrPortsCfgLowRNR -- C-LOCATOR-FUNC LocateFrPortsCfgEntry STATUS mandatory DESCRIPTION "The Lower Receiver-Not-Ready threshold. This threshold specifies the number of receiver not ready indications from the user equipment before an alarm is cleared for this connection. The valid range is (1..100) - Get Operation: Since this object is specific to LMI protocols, (-1) is returned if the network manager attempts to GET this object from a non-LMI port. - Set Operation: Likewise, if the network manager attempts to SET this object of a non-LMI port, an error is reported. Only applicable to IPX-FRP ports. The value (-2) will be returned for AXIS-FRSM ports." DEFVAL { 75 } ::= { frPortsCfgEntry 31 } frIxPortsCfgOamThresh OBJECT-TYPE SYNTAX INTEGER ACCESS read-write -- C-ACCESS-FUNC FrPortsCfgOamThresh -- C-LOCATOR-FUNC LocateFrPortsCfgEntry STATUS mandatory DESCRIPTION "The alarm threshold for number of OAM heartbeat FastPackets missed before propagating A-bit=0. This threshold is applicable to both UNI and NNI Frame Relay ports when the node has FR NNI feature enabled and this FRP firmware supports it. The valid range is (0..15). - Get Operation: Since this object is not applicable to disabled protocol, (-1) is returned if the network manager attempts to GET this object from a port without protocols. - Set Operation: If the network manager attempts to SET this object of a port without any protocol, an error is reported. Only applicable to IPX-FRP ports. The value (-2) will be returned for AXIS-FRSM ports." ::= { frPortsCfgEntry 32 } frIxPortsCfgCLLMTimer OBJECT-TYPE SYNTAX INTEGER ACCESS read-write -- C-ACCESS-FUNC FrPortsCfgCLLMTimer -- C-LOCATOR-FUNC LocateFrPortsCfgEntry STATUS mandatory DESCRIPTION "The timer for CLLM messages in CLLM intervals. No CLLM if 0 is configured. If a user configures this value to be greater than 0 then it should be in the range 4 to 35. The unit is hundredth of a sec. Note that ForeSight (CLLM) is available only if the firmware supports it. - Get Operation: If the network manager attempts to GET this object from a port where ForeSight is not supported, (-1) is returned. - Set Operation: If the network manager attempts to SET this object of a port where ForeSight is not supported, an error is reported. Only applicable to IPX-FRP ports. The value (-2) will be returned for AXIS-FRSM ports." ::= { frPortsCfgEntry 33 } frIxPortsCfgEFCItoBECN OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2), none(3) } ACCESS read-write -- C-ACCESS-FUNC FrPortsCfgEFCItoBECN -- C-LOCATOR-FUNC LocateFrPortsCfgEntry STATUS mandatory DESCRIPTION "This object indicates whether EFCI to BECN mapping is enabled. Only applicable to IPX-FRP ports. The value (-2) will be returned for AXIS-FRSM ports." ::= { frPortsCfgEntry 34 } frIxPortsCfgSrRTS OBJECT-TYPE SYNTAX INTEGER { off (1), on (2), none(3) } ACCESS read-only -- C-ACCESS-FUNC FrPortsCfgSrRTS -- C-LOCATOR-FUNC LocateFrPortsCfgEntry STATUS mandatory DESCRIPTION "The current status of the RTS lead (subrated FRI only). none is used for T1/E1 FRI. - Get Operation: This object is valid only if the port is subrated and DTE. Otherwise, none(3) is returned. Only applicable to IPX-FRP ports. The value (-2) will be returned for AXIS-FRSM ports." ::= { frPortsCfgEntry 35 } frIxPortsCfgSrDTR OBJECT-TYPE SYNTAX INTEGER { off (1), on (2), none(3) } ACCESS read-only -- C-ACCESS-FUNC FrPortsCfgSrDTR -- C-LOCATOR-FUNC LocateFrPortsCfgEntry STATUS mandatory DESCRIPTION "The current status of the DTR lead (subrated FRI only). none is used for T1/E1 FRI. - Get Operation: This object is valid only if the port is subrated and DTE. Otherwise, none(3) is returned. Only applicable to IPX-FRP ports. The value (-2) will be returned for AXIS-FRSM ports." ::= { frPortsCfgEntry 36 } frIxPortsCfgSrDCD OBJECT-TYPE SYNTAX INTEGER { off (1), on (2), none(3) } ACCESS read-only -- C-ACCESS-FUNC FrPortsCfgSrDCD -- C-LOCATOR-FUNC LocateFrPortsCfgEntry STATUS mandatory DESCRIPTION "The current status of the DCD lead (subrated FRI only). none is used for T1/E1 FRI. - Get Operation: This object is valid only if the port is subrated and DCE. Otherwise, none(3) is returned. Only applicable to IPX-FRP ports. The value (-2) will be returned for AXIS-FRSM ports." ::= { frPortsCfgEntry 37 } frIxPortsCfgSrCTS OBJECT-TYPE SYNTAX INTEGER { off (1), on (2), none(3) } ACCESS read-only -- C-ACCESS-FUNC FrPortsCfgSrCTS -- C-LOCATOR-FUNC LocateFrPortsCfgEntry STATUS mandatory DESCRIPTION "The current status of the CTS lead (subrated FRI only). none is used for T1/E1 FRI. - Get Operation: This object is valid only if the port is subrated and DCE. Otherwise, none(3) is returned. Only applicable to IPX-FRP ports. The value (-2) will be returned for AXIS-FRSM ports." ::= { frPortsCfgEntry 38 } frIxPortsCfgSrDSR OBJECT-TYPE SYNTAX INTEGER { off (1), on (2), none(3) } ACCESS read-only -- C-ACCESS-FUNC FrPortsCfgSrDSR -- C-LOCATOR-FUNC LocateFrPortsCfgEntry STATUS mandatory DESCRIPTION "The current status of the DSR lead (subrated FRI only). none is used for T1/E1 FRI. - Get Operation: This object is valid only if the port is subrated and DCE. Otherwise, none(3) is returned. Only applicable to IPX-FRP ports. The value (-2) will be returned for AXIS-FRSM ports." ::= { frPortsCfgEntry 39 } frIxPortsCfgLoopBack OBJECT-TYPE SYNTAX INTEGER { none (1), local(2) } ACCESS read-only -- C-ACCESS-FUNC FrPortsCfgLoopBack -- C-LOCATOR-FUNC LocateFrPortsCfgEntry STATUS mandatory DESCRIPTION "The loopback mode. Only applicable to IPX-FRP ports. The value (-2) will be returned for AXIS-FRSM ports." ::= { frPortsCfgEntry 40 } frIxPortsCfgExtConFail OBJECT-TYPE SYNTAX INTEGER { false (1), true (2) } ACCESS read-only -- C-ACCESS-FUNC FrPortsCfgExtConFail -- C-LOCATOR-FUNC LocateFrPortsCfgEntry STATUS mandatory DESCRIPTION "The flag indicating if the connection with the external device is lost. Only applicable to IPX-FRP ports. The value (-2) will be returned for AXIS-FRSM ports." ::= { frPortsCfgEntry 41 } frAxPortsCfgLogPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-ACCESS-FUNC FrPortsCfgLogPort -- C-LOCATOR-FUNC LocateFrPortsCfgEntry STATUS mandatory DESCRIPTION "Logical port for the given physical port. Only applicable to AXIS-FRSM ports. The value (-2) will be returned for IPX-FRP ports." ::= { frPortsCfgEntry 42 } ------------------------------------------------------------------ -- ERROR STATUS TABLE -- -- This object contains the value of the request id for the latest -- entry in the error status table. -- This value can be used to retrieve the error code and description -- for the last SET operation failed. -- ppaErrorLastIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-ACCESS-FUNC ppaErrorLastIndex STATUS mandatory DESCRIPTION "If at least one entry exists in the error status table, the value of this object contains the index corresponding to the last entry inserted in the table. If no entries have ever been inserted in the ppaErrorTable, then the agent will return 0 for a query of this variable. Actually this object is not required any more because of the new objects ppaErrorLastDesc and ppaErrorLastEcode. One can do GET directly on ppaErrorLastDesc/LastEcode." ::= { portSvc 8 } ppaErrorFlushAll OBJECT-TYPE SYNTAX INTEGER { noOp(1), flush(2) } ACCESS read-write -- C-ACCESS-FUNC ppaErrorFlushAll STATUS mandatory DESCRIPTION "Setting this object to the value 'flush' indicates to the agent that a manager would like the ppaErrorTable to be immediately flushed of all entries. A management retrieval of this object will always return the value 'noOp'. Setting this object to the value 'noOp' is invalid." ::= { portSvc 9 } -- -- The following table is used to maintain status information about -- SNMP GET/SET requests from a Manager. When an SNMP GET/SET fails, an -- entry in this table is created and the object ppaErrorLastIndex -- is updated. -- -- Note that currently only SET errors are updated in this error table. -- ppaErrorTable OBJECT-TYPE SYNTAX SEQUENCE OF PpaErrorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A List of recent Errors reported by the Ports Proxy Agent (PPA)." ::= { portSvc 10 } ppaErrorEntry OBJECT-TYPE SYNTAX PpaErrorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A General Error Status Entry." INDEX { ppaErrorReqId } -- C-NEXT-FUNC NextErrorEntry ::= { ppaErrorTable 1 } PpaErrorEntry ::= SEQUENCE { ppaErrorReqId INTEGER, ppaErrorDesc DisplayString, ppaErrorEcode INTEGER } ppaErrorReqId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only -- C-ACCESS-FUNC ppaErrorReqId -- C-LOCATOR-FUNC LocateErrorEntry STATUS mandatory DESCRIPTION "This object contains the PDU request ID associated with the SET request. The manager must use this information to find the error associated with a particular SNMP request. Note that an SNMP request ID may be reused by the same manager. When this occurs, the older entry in the table will be replaced with the new error status. Managers must be aware that error information may therefore be lost." ::= { ppaErrorEntry 1 } ppaErrorDesc OBJECT-TYPE SYNTAX DisplayString (SIZE(1..255)) ACCESS read-only -- C-ACCESS-FUNC ppaErrorDesc -- C-LOCATOR-FUNC LocateErrorEntry STATUS mandatory DESCRIPTION "This object contains error status information for failed SETS to one or more objects in one or more of the following tables: frPortsCfgTable Rows in this table may be created as the result of a failed SNMP SET operation. Since the SNMP standard allows only limited number of error result codes, the managers can retrieve this variable to get additional information on a failed SET operation. Typically this object will contain a user friendly description of the cause of the error." ::= { ppaErrorEntry 2 } ppaErrorEcode OBJECT-TYPE SYNTAX INTEGER { invalid-network(1), -- No such Network(domain) in the Database invalid-node(2), -- No such Node in the Database invalid-shelf(3), -- No such Nhelf for the given node invalid-release(4), -- Unsupported release fot the given Node/Shelf node-timeout(5), -- Timeout from the given Node/Shelf node-busy(6), -- Node is busy processing other requests no-snmpcomm(7), -- The demon process snmpcomm is not running snmpcomm-error(8), -- Internal error at the demon process snmpcomm node-error(9), -- Error at the embedded Agent bad-value(10), -- Bad value for the given Object port-not-found(11), -- The specified port does not exists slot-is-full(12), -- AddPort error, no more ports on this slot rowstatus-missing(100), -- RowStatus object is missing from the SET request port-exists(101), -- AddPort error, port already exists invalid-slot(102), -- No such slot invalid-line(103), -- No such line line-is-full(104), -- AddPort error, no more ports on this line multiple-ports(105), -- Multiple ports are specified in the request port-reserved(106), -- Port is Reserved for internal use(Signalling) na-frsm(107), -- This object is not applicable for FRSM ports na-frp(108), -- This object is not applicable for FRP ports no-up-down-frsm(109), -- RowStatus can not be up-frp and down-frp for frsm ports invalid-set(110), -- SET is allowed for addport only illegal-set(111), -- Dependency on other parameter values partial-add(112), -- Added the port, but unable to modify params no-error-entry(500), -- No entries available in the ErrorTable not-applicable(501), -- Error Code not relevant, rely on Error Description invalid-flushall(502) -- Can not set to noOp for ppaErrorFlushAll } ACCESS read-only -- C-ACCESS-FUNC ppaErrorEcode -- C-LOCATOR-FUNC LocateErrorEntry STATUS mandatory DESCRIPTION "This object contains the error Code of the GET/SET operation. The error Codes from 500 onwards are specific to the Error Table operation itself. Note that currently GET errors are not updated in the error table." ::= { ppaErrorEntry 3 } ppaErrorLastDesc OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) ACCESS read-only -- C-ACCESS-FUNC ppaErrorLastDesc STATUS mandatory DESCRIPTION "This contains the error description of the last error generated. If error table contains no errors, GET on this will return NULL string" ::= { portSvc 11 } ppaErrorLastEcode OBJECT-TYPE SYNTAX INTEGER { invalid-network(1), -- No such Network(domain) in the Database invalid-node(2), -- No such Node in the Database invalid-shelf(3), -- No such Nhelf for the given node invalid-release(4), -- Unsupported release fot the given Node/Shelf node-timeout(5), -- Timeout from the given Node/Shelf node-busy(6), -- Node is busy processing other requests no-snmpcomm(7), -- The demon process snmpcomm is not running snmpcomm-error(8), -- Internal error at the demon process snmpcomm node-error(9), -- Error at the embedded Agent bad-value(10), -- Bad value for the given Object port-not-found(11), -- The specified port does not exists slot-is-full(12), -- AddPort error, no more ports on this slot rowstatus-missing(100), -- RowStatus object is missing from the SET request port-exists(101), -- AddPort error, port already exists invalid-slot(102), -- No such slot invalid-line(103), -- No such line line-is-full(104), -- AddPort error, no more ports on this line multiple-ports(105), -- Multiple ports are specified in the request port-reserved(106), -- Port is Reserved for internal use(Signalling) na-frsm(107), -- This object is not applicable for FRSM ports na-frp(108), -- This object is not applicable for FRP ports no-up-down-frsm(109), -- RowStatus can not be up-frp and down-frp for frsm ports invalid-set(110), -- SET is allowed for addport only illegal-set(111), -- Dependency on other parameter values partial-add(112), -- Added the port, but unable to modify params no-error-entry(500), -- No entries available in the ErrorTable not-applicable(501), -- Error Code not relevant, rely on Error Description invalid-flushall(502) -- Can not set to noOp for ppaErrorFlushAll } ACCESS read-only -- C-ACCESS-FUNC ppaErrorLastEcode STATUS mandatory DESCRIPTION "This contains the error code of the last error generated. If error table contains no errors, GET on this object returns 500" ::= { portSvc 12 } -- The following few defs are duplicate. The same defs have been defined -- in the SV+Network.mib. -- trapsConfig OBJECT IDENTIFIER ::= { rtm 1 } -- lastSequenceNumber OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS read-only -- C-STRUCT proxy-ctxt, FIELD lastTrapSeqNum -- STATUS mandatory -- DESCRIPTION "The Sequence Number of the last trap generated on the SNMP Proxy" -- ::= { trapsConfig 3 } userConnCleared TRAP-TYPE ENTERPRISE svplus VARIABLES { lastSequenceNumber, connectionLocalEndPt, connectionLocalStr, connectionRemoteEndPt, connectionRemoteStr, connectionOpStatus, connectionAbitStatus, connectionType } DESCRIPTION "The ' User Connection has recovered from failed/downed state" ::= 10000 userConnFailed TRAP-TYPE ENTERPRISE svplus VARIABLES { lastSequenceNumber, connectionLocalEndPt, connectionLocalStr, connectionRemoteEndPt, connectionRemoteStr, connectionOpStatus, connectionAbitStatus, connectionType } DESCRIPTION "The User Connection has failed" ::= 10001 userConnDown TRAP-TYPE ENTERPRISE svplus VARIABLES { lastSequenceNumber, connectionLocalEndPt, connectionLocalStr, connectionRemoteEndPt, connectionRemoteStr, connectionOpStatus, connectionAbitStatus, connectionType } DESCRIPTION "The User Connection has been downed" ::= 10002 -- The following describes the MIB variables for the atmTrunks table. -- -- -------------------------------------- -- Configuring a physical/virtual trunk: -- -------------------------------------- -- ----------------------------------------------------------------------------- -- | Before addtrk | After addtrk | -- ----------------------------------------------------------------------------- -- Trunk Params | PHY TRK | VIR TRK | PHY TRK | VIR TRK | -- ----------------------------------------------------------------------------- -- atmTrkXmitRate | Yes | Yes | No | No | -- atmTrksResChans | No | Yes | No | Yes | -- atmTrkVPI | No | Yes | No | No | -- atmTrkType | No | Yes | No | No | -- atmTrkTrfCls | Yes | Yes | Yes | Yes | -- atmTrkPassSync | Yes | Yes | Yes | Yes | -- atmTrkStatRes | Yes | Yes | Yes | Yes | -- atmTrkLoopClock | Yes | Yes | Yes | Yes | -- atmTrkSvcChannels | Yes | No | No | No | -- atmTrkSvcBw | Yes | No | No | No | -- ----------------------------------------------------------------------------- -- -- Note: Above table lists ATM trunk parameters which can be configured before -- addtrk or after. This table can be refererence before adding a trunk -- or after adding a trunk. -- -- atmTrunks OBJECT-TYPE SYNTAX SEQUENCE OF AtmTrkEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of atmTrk interfaces" --DEFAULT test-function test-atmrtetrktable --DEFAULT next-function next-atmrtetrktable --DEFAULT get-function get-atmrtetrktable-%t ::= { trunkServiceObjects 2 } atmTrkEntry OBJECT-TYPE SYNTAX AtmTrkEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A interface entry" INDEX { switchIfIndex } ::= { atmTrunks 1 } AtmTrkEntry ::= SEQUENCE { atmTrkStatus INTEGER, atmTrkAlmEnable INTEGER, atmTrkComStatus INTEGER, atmTrkRcvRate INTEGER, atmTrkTrnsCap INTEGER, atmTrkTrnsLoad INTEGER, atmTrkRcvCap INTEGER, atmTrkRcvLoad INTEGER, atmTrkType INTEGER, atmTrkVPI INTEGER, atmTrkResChans INTEGER, atmTrkTrafCls INTEGER, atmTrkOeNdType INTEGER, atmTrkOeName DisplayString, atmTrkOeIpAddr IpAddress, atmTrkOeIfIndex INTEGER, atmTrkOeDomain INTEGER, atmTrkSvcChannels INTEGER, atmTrkShareLcn INTEGER, atmTrkSvcLcnLow INTEGER, atmTrkSvcLcnHigh INTEGER, atmTrkSvcVpiLow INTEGER, atmTrkSvcVpiHigh INTEGER, atmTrkSvcVciLow INTEGER, atmTrkSvcVciHigh INTEGER, atmTrkSvcQbinBitMap OCTET STRING, atmTrkSvcQbinSz INTEGER, atmTrkSvcBw INTEGER, atmTrkSvcInUse INTEGER, atmTrkXmitRate INTEGER, atmTrkPassSync INTEGER, atmTrkStatRes INTEGER, atmTrkLoopClock INTEGER, atmTrkBdataBTxQlen INTEGER, atmTrkBdataBRxQlen INTEGER, atmTrkBdataBTxEfcn INTEGER, atmTrkBdataBRxEfcn INTEGER, atmTrkBdataBTxHiClp INTEGER, atmTrkBdataBRxHiClp INTEGER, atmTrkBdataBTxLoClp INTEGER, atmTrkBdataBRxLoClp INTEGER, atmTrkMaxChanPort INTEGER, atmTrkLinkType INTEGER, atmTrkDerouteDelayTimer INTEGER, atmTrkGtwyChCount INTEGER, atmTrkRetainedLinks INTEGER, atmTrkImaWindowSize INTEGER, atmTrkImaTrnsCnts INTEGER, atmTrkImaReenableTimer INTEGER } atmTrkStatus OBJECT-TYPE SYNTAX INTEGER { clear(1), minor(2), major(3), down(4), deact(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Alarms state for logical interface table row." ::= { atmTrkEntry 1 } atmTrkAlmEnable OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "A writable object to disable a trunk alarm." --DEFAULT test-function test-trkalmenable ::= { atmTrkEntry 2 } atmTrkComStatus OBJECT-TYPE SYNTAX INTEGER { commOK(1), commFAIL(2) } ACCESS read-only STATUS mandatory DESCRIPTION " The communication status of the protocol on this trunk." ::= { atmTrkEntry 3 } atmTrkRcvRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Unit of ATM Trunk Receive Rate is based on card types. UXM, and ALM-A: cells per second Other cards: 1000 packets per second " ::= { atmTrkEntry 4 } atmTrkTrnsCap OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The Transmit Capacity on this trunk in cells per second." ::= { atmTrkEntry 5 } atmTrkTrnsLoad OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The Transmit Load on this trunk in cells per second." ::= { atmTrkEntry 6 } atmTrkRcvCap OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The Receive Capacity on this trunk in cells per second." ::= { atmTrkEntry 7 } atmTrkRcvLoad OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The Receive Load on this trunk in cells per second." ::= { atmTrkEntry 8 } atmTrkType OBJECT-TYPE SYNTAX INTEGER { trkTypePHY(1), trkTypeCBR(2), trkTypeVBR(3), trkTypeABR(4), trkTypeIPXAF(5), trkTypeAXISAF(6) } ACCESS read-write STATUS mandatory DESCRIPTION " The type this trunk. The values of trkTypeCBR(2), trkTypeVBR(3), and trkTypeABR(4) are writable for virtual trunks only. The trkTypePHY(1) value is returned for a get-request on a physical trunk." ::= { atmTrkEntry 9 } atmTrkVPI OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " The VPI used on this virtual trunk. The maximum value is 255 for ds3 trunks, and 63 for OC3 trunks. The minimum value for set-request PDUs is 1. This value must be unique on a physical trunk port and also must match the value for the path through the ATM cloud. The object cannot be set in IPX/IGX." ::= { atmTrkEntry 10 } atmTrkResChans OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " The number of channels reserved for this trunk." ::= { atmTrkEntry 11 } atmTrkTrafCls OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " An integer containing bits representing the traffic classes of this trunk: bit0 Voice, bit1 Time Stamped, bit2 Non-Time Stamped, bit3 Frame Relay, bit4 not used, bit5 ForeSight, bit6 ATM CBR, bit7 ATM VBR, bit8 ATM ABR. " ::= { atmTrkEntry 12 } atmTrkOeNdType OBJECT-TYPE SYNTAX INTEGER { ndTypeOther(1), ndTypeIPX(2), ndTypeBPX(3), ndTypeIPXAF(4), ndTypeAXIS(5), ndTypeIGX(6), ndTypeIGXAF(7) } ACCESS read-only STATUS mandatory DESCRIPTION " The type of node or shelf at the other end of this trunk." ::= { atmTrkEntry 13 } atmTrkOeName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION " The name of shelf at the other end of this trunk." ::= { atmTrkEntry 14 } atmTrkOeIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION " The IP address of shelf at the other end of this trunk." ::= { atmTrkEntry 15 } atmTrkOeIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The switchIfIndex at the other end of this trunk." ::= { atmTrkEntry 16 } atmTrkOeDomain OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The domain of the shelf at the other end of this trunk." ::= { atmTrkEntry 17 } atmTrkSvcChannels OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of LCN's reserved for the SVC's on this trunk. The other SVC parms are valid if this object has a non-zero value." --DEFAULT test-function test-atmsvcparm ::= { atmTrkEntry 18 } atmTrkShareLcn OBJECT-TYPE SYNTAX INTEGER { portBased(1), cardBased(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Whether the LCN's are shared per port basis or per card basis." --DEFAULT test-function test-atmsvcparm ::= { atmTrkEntry 19 } atmTrkSvcLcnLow OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The lower limit of the LCN value which can be used on this trunk --DEFAULT test-function test-atmsvcparm for SVC's." ::= { atmTrkEntry 20 } atmTrkSvcLcnHigh OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The Upper limit of the LCN value which can be used on this trunk for SVC's." --DEFAULT test-function test-atmsvcparm ::= { atmTrkEntry 21 } atmTrkSvcVpiLow OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "It stores the SVC VPI lower limit. The partitioning is based on the STI Header VC-format. The 16 bit concatenated VPI/VCI field is partitioned between PVC and SVC. On a physical trunk a range will be reserved for SVC's." --DEFAULT test-function test-atmsvcparm ::= { atmTrkEntry 22 } atmTrkSvcVpiHigh OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "It stores the SVC VPI Upper limit. The partitioning is based on the STI Header VC-format. The 16 bit concatenated VPI/VCI field is partitioned between PVC and SVC. On a physical trunk a range will be reserved for SVC's." --DEFAULT test-function test-atmsvcparm ::= { atmTrkEntry 23 } atmTrkSvcVciLow OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "It stores the SVC VCI Lower limit." --DEFAULT test-function test-atmsvcparm ::= { atmTrkEntry 24 } atmTrkSvcVciHigh OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "It stores the SVC VCI Upper limit." --DEFAULT test-function test-atmsvcparm ::= { atmTrkEntry 25 } atmTrkSvcQbinBitMap OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A 32-bit Octet string which represents the queue bin allocation. If the bit is set to 1, it is allocated to SVC's and if 0 it is allocated to PVC's. The bits are numbered in the BIG endian order, the m.s bit corresponds to Qbin0 and the next m.s bit corresponds to Qbin 1 etc.For ex. atmTrkSvcQbinMap is set to a value 0x8fff0000 to indicate that queues 0 and 4 through 15 are allocated to SVC 's. This object is valid if atmPortSvcChannels is non-zero." --DEFAULT test-function test-atmsvcparm ::= { atmTrkEntry 26 } atmTrkSvcQbinSz OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The Egress Queue pool size." --DEFAULT test-function test-atmsvcparm ::= { atmTrkEntry 27 } atmTrkSvcBw OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The bandwidth partition available for SVC's." --DEFAULT test-function test-atmsvcparm ::= { atmTrkEntry 28 } atmTrkSvcInUse OBJECT-TYPE SYNTAX INTEGER { inUse (1), notInUse(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is set by the INS to indicate that SVC partitioning information is being used by INS. The initial value is notInUse. This object is valid if atmPortSvcChannels is non-zero." --DEFAULT test-function test-atmsvcparm ::= { atmTrkEntry 29 } atmTrkXmitRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The trunk transmission rate in unit of cells per second. * The default values for this object are, ---------------------------------------------------- Back Card Type | Physical Trunk | Virtual Trunk ---------------------------------------------------- T3 | 96000 | 3000 E3 | 80000 | 2500 OC3 | 353208 | 32109 ---------------------------------------------------- * This object can't be set if the routing trunk is added and the trunk is a physical trunk. It can be set if this is a virtual trunk no matter whether the routing trunk is established or not. * This object can be set with other writable objects in this table except atmRteTrkAlmEnable, atmRteTrkBdataBTxQlen, atmRteTrkBdataBTxEfcn, atmRteTrkBdataBTxHiClp, atmRteTrkBdataBTxLoClp. " ::= { atmTrkEntry 30 } atmTrkPassSync OBJECT-TYPE SYNTAX INTEGER { yes (1), no(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The selection of this trunk to pass synchronization to the network clock. * The default value for this object is yes(1). * X.21 subrate trunk cannot pass sync. * V.35 and MIL-188 PLNs can only pass sync if the date rate is 256, 512, or 1024 kbps, since these are the only rates for which the NTC-SR accepts clock from the SCC. * This object can be set with other writable objects in this table except atmRteTrkAlmEnable, atmRteTrkBdataBTxQlen, atmRteTrkBdataBTxEfcn, atmRteTrkBdataBTxHiClp, atmRteTrkBdataBTxLoClp. " ::= { atmTrkEntry 31 } atmTrkStatRes OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The Statistical Reserve in cells per second for this trunk. * The default value for this object is 1000. * This can be set with other writable objects in this table except atmRteTrkAlmEnable, atmRteTrkBdataBTxQlen, atmRteTrkBdataBTxEfcn, atmRteTrkBdataBTxHiClp, atmRteTrkBdataBTxLoClp. " ::= { atmTrkEntry 32 } atmTrkLoopClock OBJECT-TYPE SYNTAX INTEGER { yes (1), no(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object indicates if this trunk has been configured to loop receive clock back to transmit. * If local end is configured to pass sync, don't loop clock; * If the interface is X.21, loop clook is not supported. * The default value for this object is no(2). * This object can be set with other writable objects in this table except atmRteTrkAlmEnable, atmRteTrkBdataBTxQlen, atmRteTrkBdataBTxEfcn, atmRteTrkBdataBTxHiClp, atmRteTrkBdataBTxLoClp,atmRteTrkBdataBRxQlen, atmRteTrkBdataBRxEfcn, atmRteTrkBdataBRxHiClp and atmRteTrkBdataBRxLoClp. " ::= { atmTrkEntry 33 } atmTrkBdataBTxQlen OBJECT-TYPE SYNTAX INTEGER (-1..8000) ACCESS read-write STATUS mandatory DESCRIPTION "The depth of Bursty Data B transmission queue (in decimal). * This object is not applicable (-1) to IPX/IGX ATM trunks. * The default value for this object is 8000. * This object can only be set together with atmRteTrkBdataBTxEfcn,atmRteTrkBdataBTxHiClp and atmRteTrkBdataBTxLoClp on BPX ATM trunks. " --DEFAULT test-function test-atmrtetrkparms ::= { atmTrkEntry 34 } atmTrkBdataBRxQlen OBJECT-TYPE SYNTAX INTEGER (-1..8000) ACCESS read-write STATUS mandatory DESCRIPTION "The depth of Bursty Data B receiving queue (in decimal). * This object is not applicable (-1) to BPX ATM trunk (BNI or BXM). * The default value for this object is 8000. * This object can only be set together with atmRteTrkBdataBRxEfcn, atmRteTrkBdataBRxHiClp and atmRteTrkBdataBRxLoClp on IPX ATM trunks " --DEFAULT test-function test-atmrtetrkparms ::= { atmTrkEntry 35 } atmTrkBdataBTxEfcn OBJECT-TYPE SYNTAX INTEGER (-1..8000) ACCESS read-write STATUS mandatory DESCRIPTION "The transmission EFCN threshold (in decimal) for Bursty Data B of this trunk. * This object is not applicable (-1) to IPX/IGX ATM trunks. * The default value for this object is 8000. * This object can only be set together with atmRteTrkBdataBTxQlen,atmRteTrkBdataBTxHiClp and atmRteTrkBdataBTxLoClp on BPX ATM trunks. " --DEFAULT test-function test-atmrtetrkparms ::= { atmTrkEntry 36 } atmTrkBdataBRxEfcn OBJECT-TYPE SYNTAX INTEGER (-1..8000) ACCESS read-write STATUS mandatory DESCRIPTION "The receiving EFCN threshold (in decimal) for Bursty Data B of this trunk. * This object is not applicable (-1) to BPX ATM trunk (BNI or BXM). * The default value for this object is 8000. * This object can only be set together with atmRteTrkBdataBRxQlen, atmRteTrkBdataBRxHiClp and atmRteTrkBdataBRxLoClp on IPX ATM trunks. " --DEFAULT test-function test-atmrtetrkparms ::= { atmTrkEntry 37 } atmTrkBdataBTxHiClp OBJECT-TYPE SYNTAX INTEGER (-1..100) ACCESS read-write STATUS mandatory DESCRIPTION "The transmission high CLP threshold (in percentage) for Bursty Data B of this trunk. * The default value for this object is 75. * This object is not applicable (-1) to IPX/IGX ATM trunks. * This object can only be set together with atmRteTrkBdataBTxEfcn,atmRteTrkBdataBTxQlen and atmRteTrkBdataBTxLoClp on BPX ATM trunks. " --DEFAULT test-function test-atmrtetrkparms ::= { atmTrkEntry 38 } atmTrkBdataBRxHiClp OBJECT-TYPE SYNTAX INTEGER (-1..100) ACCESS read-write STATUS mandatory DESCRIPTION "The receiving high CLP threshold (in percentage) for Bursty Data B of this trunk. This object is not applicable (-1) to BPX ATM trunk (BNI or BXM). * The default value for this object is 75. * This object can only be set together with atmRteTrkBdataBRxEfcn, atmRteTrkBdataBRxQlen and atmRteTrkBdataBRxLoClp on IPX ATM trunks " --DEFAULT test-function test-atmrtetrkparms ::= { atmTrkEntry 39 } atmTrkBdataBTxLoClp OBJECT-TYPE SYNTAX INTEGER (-1..100) ACCESS read-write STATUS mandatory DESCRIPTION "The transmission low CLP threshold (in percentage) for Burstry Data B of this trunk.This object is not applicable (-1) to IPX or IGX ATM trunks. * The default value for this object is 25. * This object can only be set together with atmRteTrkBdataBTxEfcn,atmRteTrkBdataBTxHiClp and atmRteTrkBdataBTxQlen on BPX ATM trunks. " --DEFAULT test-function test-atmrtetrkparms ::= { atmTrkEntry 40 } atmTrkBdataBRxLoClp OBJECT-TYPE SYNTAX INTEGER (-1..100) ACCESS read-write STATUS mandatory DESCRIPTION "The receiving low CLP threshold (in percentage ) for Bursty Data B of this trunk. This object is not applicable (-1) to BPX ATM trunk (BNI or BXM). * The default value for this object is 25. * This object can only be set together with atmRteTrkBdataBRxEfcn, atmRteTrkBdataBRxHiClp and atmRteTrkBdataBRxQlen on IPX ATM trunks " --DEFAULT test-function test-atmrtetrkparms ::= { atmTrkEntry 41 } atmTrkMaxChanPort OBJECT-TYPE SYNTAX INTEGER (-1..16320) ACCESS read-write STATUS mandatory DESCRIPTION "The maximum number of channels a BXM trunk port can support. This object is applicable to BXM trunk only. * The default value for this object is 1484. * This object can be set with other writable objects in this table except atmRteTrkAlmEnable, atmRteTrkBdataBTxQlen, atmRteTrkBdataBTxEfcn, atmRteTrkBdataBTxHiClp and atmRteTrkBdataBTxLoClp. " --DEFAULT view-mask BPX-VIEW | IGX-VIEW ::= { atmTrkEntry 42 } atmTrkLinkType OBJECT-TYPE SYNTAX INTEGER { terrestrial(1), satellite(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The physical link type of the trunk. The default value for this object is terrestrial(1). * This object can be set with other writable objects in this table except atmRteTrkAlmEnable, atmRteTrkBdataBTxQlen, atmRteTrkBdataBTxEfcn, atmRteTrkBdataBTxHiClp and atmRteTrkBdataBTxLoClp. " ::= { atmTrkEntry 43 } atmTrkDerouteDelayTimer OBJECT-TYPE SYNTAX INTEGER (0..300) ACCESS read-write STATUS mandatory DESCRIPTION "The deroute delay timer of the trunk in unit of second. * The default value for this object is 0. * This object can be set with other writable objects in this table except atmRteTrkAlmEnable, atmRteTrkBdataBTxQlen, atmRteTrkBdataBTxEfcn, atmRteTrkBdataBTxHiClp and atmRteTrkBdataBTxLoClp. " ::= { atmTrkEntry 44 } atmTrkGtwyChCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The Gateway Channel count for UXM cards. * This cannot exceed the total number channels per port." --DEFAULT view-mask IGX-VIEW ::= { atmTrkEntry 45 } atmTrkRetainedLinks OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-write STATUS mandatory DESCRIPTION "No of retained links, This is for UXM T1-IMA mode only " --DEFAULT view-mask IGX-VIEW ::= { atmTrkEntry 46 } atmTrkImaWindowSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "If this object which is the Window size is zero then additional information is not requested, which are the objects given below. This is for UXM E1/T1-IMA mode only " --DEFAULT view-mask IGX-VIEW ::= { atmTrkEntry 47 } atmTrkImaTrnsCnts OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " This object can be set only if the Window Size is non-zero. This is Maximum transition counts/window This is for UXM E1/T1-IMA mode only " --DEFAULT view-mask IGX-VIEW ::= { atmTrkEntry 48 } atmTrkImaReenableTimer OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This object can be set only if the Window Size is non-zero. This is re-enable timer If 0 is disable else it is in 10min units. This is for UXM T1-IMA mode only " --DEFAULT view-mask IGX-VIEW ::= { atmTrkEntry 49 } -- The following describes the MIB variables for the atmTrunkStatsTable. atmTrunkStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmTrkStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of ATM trunk statistics object." --DEFAULT test-function test-atmtrkstatstable --DEFAULT next-function next-atmtrkstatstable --DEFAULT get-function get-atmtrkstatstable-%t ::= { trunkServiceObjects 4 } atmTrkStatsEntry OBJECT-TYPE SYNTAX AtmTrkStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A interface entry" INDEX { switchIfIndex } ::= { atmTrunkStatsTable 1 } AtmTrkStatsEntry ::= SEQUENCE { atmTrkStatsTxVoPktDrps Counter, atmTrkStatsTxTsPktDrps Counter, atmTrkStatsTxNonTsPktDrps Counter, atmTrkStatsTxHiPrioPktDrps Counter, atmTrkStatsTxBdataAPktDrps Counter, atmTrkStatsTxBdataBPktDrps Counter, atmTrkStatsRxVoPktDrps Counter, atmTrkStatsRxTsPktDrps Counter, atmTrkStatsRxNonTsPktDrps Counter, atmTrkStatsRxHiPrioPktDrps Counter, atmTrkStatsRxBdataAPktDrps Counter, atmTrkStatsRxBdataBPktDrps Counter, atmTrkStatsSpacerPktsDrps Counter, atmTrkStatsTotalPktsTxtoLns Counter, atmTrkStatsTotalPktsRxFromLns Counter, atmTrkStatsTxVoCellDrps Counter, atmTrkStatsTxTsCellDrps Counter, atmTrkStatsTxNonTsCellDrps Counter, atmTrkStatsTxHiPrioCellDrps Counter, atmTrkStatsTxBdataACellDrps Counter, atmTrkStatsTxBdataBCellDrps Counter, atmTrkStatsTxCbrCellDrps Counter, atmTrkStatsTxVbrCellDrps Counter, atmTrkStatsTxAbrCellDrps Counter, atmTrkStatsTotalCellsTxtoLns Counter, atmTrkStatsTotalCellsRxFromPorts Counter } atmTrkStatsTxVoPktDrps OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of transmitted voice fast packet dropped. This statistics is not applicatable to BPX trunks, 0 is returned for BPX trunks. " ::= { atmTrkStatsEntry 1 } atmTrkStatsTxTsPktDrps OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of transmitted time-stamped packet dropped. This statistics is not applicatable to BPX trunks, 0 is returned for BPX trunks. " ::= { atmTrkStatsEntry 2 } atmTrkStatsTxNonTsPktDrps OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of transmitted non time-stamped packet dropped. This statistics is not applicatable to BPX trunks, 0 is returned for BPX trunks. " ::= { atmTrkStatsEntry 3 } atmTrkStatsTxHiPrioPktDrps OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of transmitted high priority packet dropped. This statistics is not applicatable to BPX trunks, 0 is returned for BPX trunks. " ::= { atmTrkStatsEntry 4 } atmTrkStatsTxBdataAPktDrps OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of transmitted bursty data A packet dropped. This statistics is not applicatable to BPX trunks, 0 is returned for BPX trunks. " ::= { atmTrkStatsEntry 5 } atmTrkStatsTxBdataBPktDrps OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of transmitted bursty data B packet dropped. This statistics is not applicatable to BPX trunks, 0 is returned for BPX trunks. " ::= { atmTrkStatsEntry 6 } atmTrkStatsRxVoPktDrps OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of received voice packet dropped. This statistics is not applicatable to BPX trunks, 0 is returned for BPX trunks. " ::= { atmTrkStatsEntry 7 } atmTrkStatsRxTsPktDrps OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of received time-stamped packet dropped. This statistics is not applicatable to BPX trunks, 0 is returned for BPX trunks. " ::= { atmTrkStatsEntry 8 } atmTrkStatsRxNonTsPktDrps OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of received non time-stamped packet dropped. This statistics is not applicatable to BPX trunks, 0 is returned for BPX trunks. " ::= { atmTrkStatsEntry 9 } atmTrkStatsRxHiPrioPktDrps OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of received high priority packet dropped. This statistics is not applicatable to BPX trunks, 0 is returned for BPX trunks. " ::= { atmTrkStatsEntry 10 } atmTrkStatsRxBdataAPktDrps OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of received bursty data A packet dropped. This statistics is not applicatable to BPX trunks, 0 is returned for BPX trunks. " ::= { atmTrkStatsEntry 11 } atmTrkStatsRxBdataBPktDrps OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of received bursty data B packet dropped. This statistics is not applicatable to BPX trunks, 0 is returned for BPX trunks. " ::= { atmTrkStatsEntry 12 } atmTrkStatsSpacerPktsDrps OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of received Spacer Packet dropped. This statistics is not applicatable to BPX trunks, 0 is returned for BPX trunks. " ::= { atmTrkStatsEntry 13 } atmTrkStatsTotalPktsTxtoLns OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of total packets transmitted to the line. This statistics is not applicatable to BPX trunks, 0 is returned for BPX trunks. " ::= { atmTrkStatsEntry 14 } atmTrkStatsTotalPktsRxFromLns OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of total packets received from the line. This statistics is not applicatable to BPX trunks, 0 is returned for BPX trunks. " ::= { atmTrkStatsEntry 15 } atmTrkStatsTxVoCellDrps OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of transmitted ATM voice cell dropped. This statistics is not applicable to ATM Virtual Trunks, 0 is returned for ATM Virtual trunks. " ::= { atmTrkStatsEntry 16 } atmTrkStatsTxTsCellDrps OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of transmitted time-stamped ATM cell dropped. This statistics is not applicable to ATM Virtual Trunks. 0 is returned for ATM Virtual trunks. " ::= { atmTrkStatsEntry 17 } atmTrkStatsTxNonTsCellDrps OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of transmitted non time-stamped ATM cell dropped. This statistics is not applicable to ATM Virtual Trunks. 0 is returned for ATM Virtual trunks. " ::= { atmTrkStatsEntry 18 } atmTrkStatsTxHiPrioCellDrps OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of transmitted high priority ATM cell dropped. This statistics is not applicable to ATM Virtual Trunks. 0 is returned for ATM Virtual trunks. " ::= { atmTrkStatsEntry 19 } atmTrkStatsTxBdataACellDrps OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of transmitted bursty data A cell dropped. This statistics is not applicable to ATM Virtual Trunks. 0 is returned for ATM Virtual trunks. " ::= { atmTrkStatsEntry 20 } atmTrkStatsTxBdataBCellDrps OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of transmitted bursty data B cell dropped. This statistics is not applicable to ATM Virtual Trunks. 0 is returned for ATM Virtual trunks. " ::= { atmTrkStatsEntry 21 } atmTrkStatsTxCbrCellDrps OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of transmitted ATM CBR cell dropped. This statistics is not applicable to IPX/IGX ATM trunks. 0 is returned for IPX/IGX ATM trunks. " ::= { atmTrkStatsEntry 22 } atmTrkStatsTxVbrCellDrps OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of transmitted ATM VBR cell dropped. This statistics is not applicable to IPX/IGX ATM trunks. 0 is returned for IPX/IGX ATM trunks. " ::= { atmTrkStatsEntry 23 } atmTrkStatsTxAbrCellDrps OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of transmitted ATM ABR cell dropped. This statistics is not applicable to IPX/IGX ATM trunks. 0 is returned for IPX/IGX ATM trunks. " ::= { atmTrkStatsEntry 24 } atmTrkStatsTotalCellsTxtoLns OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of total cells transmitted to the line." ::= { atmTrkStatsEntry 25 } atmTrkStatsTotalCellsRxFromPorts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of total cells received from the port." ::= { atmTrkStatsEntry 26 } END