-- MCC16-MIB, TRANSITION NETWORKS, INC. -- (Formerly a portion of TNI-MIB) -- -- SUSPEND OEM EDITING -- MIB Release 3.00.65 02/22/05 - Added cmefg100 Table and entries -- MIB Release 3.00.64 02/05/04 - Changed crs2f100RmtDCE to read-only and -- crs4f100Table with entries -- MIB Release 3.00.63 01/05/04 - Changed ccscf100LineBuildout to read-write -- MIB Release 3.00.62 10/06/03 - Added crmfe100MbTxFxBwa and crmfe100MbFxTxBwa -- MIB Release 3.00.61 08/19/03 - Added crs2f100Table and entries -- MIB Release 3.00.60 07/18/03 - Added cpsConnector types 34 and 35 -- MIB Release 3.00.60 06/10/03 - Edited crmfe100Table and descriptions -- MIB Release 3.00.59 05/28/03 - Added crmfe100Table and entries -- MIB Release 3.00.58 05/14/03 - Added captf100Emulates -- MIB Release 3.00.57 04/18/03 - Added cgetf100PauseType, cgetf100FiberAutoNegot, -- smacf100AgingTimer -- MIB Release 3.00.56 04/15/03 - Added cgfeb100Table and entries, cbftf100RedundantPath -- MIB Release 3.00.55 03/24/03 - Added two more entries under CpsConnector -- MIB Release 3.00.54 03/13/03 - Added cbftf150Table and related entries -- MIB Release 3.00.53 03/12/03 - Added cfetf205Table and related entries -- MIB Release 3.00.52 01/30/03 - Updated descriptions in cpsmp110Table, -- cbftf100Table, and smacf100PTable -- MIB Release 3.00.51 01/10/03 - Added cpsmc0800 Table and entries -- MIB Release 3.00.50 11/27/02 - Updated smacf100 variable descriptions -- MIB Release 3.00.49 11/26/02 - Added software read-write for cfetf100FarEndFault -- MIB Release 3.00.48 11/07/02 - Added notSupported(3) to csdtf100CopperLoopback -- MIB Release 3.00.47 10/02/02 - Added CacheClean variable to all Point -- system slide-in devices. Updated description -- field for cpsvt100, cemtf100, and captf100. -- Updated enumerations for cpsvt100TermTiming. -- MIB Release 3.00.46 08/01/02 - Added enumerations to variables in -- the cpsvt100Table -- MIB Release 3.00.45 07/26/02 - Added smacf100SNMPModuleInstalled -- MIB Release 3.00.44 07/11/02 - Added captf100Table -- MIB Release 3.00.43 07/08/02 - Added cpsvt100 and cemtf100Table -- MIB Release 3.00.42 06/24/02 - Added smacf100PAdvPause -- MIB Release 3.00.41 06/05/02 - Added several Smacf100P and Smacf100 entries -- MIB Release 3.00.40 05/22/02 - Documented Smacf100PTable entries -- MIB Release 3.00.39 05/15/02 - Added many Smacf100 Port variables -- MIB Release 3.00.38 05/09/02 - Added pSCabinetAdded/Removed traps -- MIB Release 3.00.37 04/30/02 - Added CDFTF100Table and its entries -- MIB Release 3.00.36 04/19/02 - Document smacf100PTx/RxOctets, WrapOctets -- MIB Release 3.00.35 04/16/02 - Documented descriptions of cpsld100, -- added smaf100PSACCfg -- MIB Release 3.00.34 03/20/02 - Added cpsld100ID and cpsld100Table -- MIB Release 3.00.33 03/19/02 - Updated smacf100PTable entries -- MIB Release 3.00.32 03/13/02 - Updated description of cfetf100FarEndFault -- MIB Release 3.00.31 03/08/02 - Added smacf100PSubDeviceIndex -- and smacf100PSTPState -- MIB Release 3.00.30 01/24/02 - Added SMACF100Table, SMACF100PFullDuplex, -- SMACF100PSACStat, SMACF100PAutoNegot, and -- advertised speeds -- MIB Release 3.00.29 01/22/02 - Added SMACF100P100Mbps variable -- MIB Release 3.00.28 01/17/02 - Added SMACF100PTable, SMACF100 cabinet Id's -- MIB Release 3.00.27 12/28/01 - Added remote management (Rmt) variables -- to csdtf100Table -- MIB Release 3.00.26 12/03/01 - Added chassisCpsColonyLCId and -- chassisCpsCpsmc1900Id -- MIB Release 3.00.25 11/30/01 - Added cpsConnector scsimplex(29) -- MIB Release 3.00.24 11/06/01 - Doc cleanup, add csdtf100FiberLoopback, -- cbftf100FormFactor values. -- MIB Release 3.00.23 09/25/01 - Added cfetf105Table and cfetf105Id -- MIB Release 3.00.22 09/19/01 - Added ccscf100Table and ccscf100Id -- MIB Release 3.00.21 09/13/01 - Added connectorType 27 and 28, scsmsh -- (SC Singlemode Short Haul) and stmmlh -- (ST Multimode Long Haul), respectively -- MIB Release 3.00.20 08/22/01 - Added notSupported(3) to cfetf100TPActivity and -- cfetf100FiberActivity -- MIB Release 3.00.19 08/17/01 - Obsoleted cpsmm100TNTRIP and cpsmm100TNTRIPMask -- MIB Release 3.00.18 08/15/01 - Added cpsConnector types for MTRJ-SM and -- Universal 26-pin Serial Interface Connector. -- MIB Release 3.00.17 07/27/01 - Added cpsmm100SNMPTrpMgr entries "2" through "4" -- MIB Release 3.00.16 04/30/01 - Added cbftf100LinkPassThrough -- MIB Release 3.00.15 04/27/01 - Added cbftf100 and cetct100 -- MIB Release 3.00.14 04/14/01 - Added Point System specific traps -- MIB Release 3.00.13 04/02/01 - Added last gasp feature to CPSMM100, -- and add the CPSMC0200 -- MIB Release 3.00.12 03/01/01 - Added CPSMP110CurrentSensorCount, -- CPSMP110FanCount, CPSMP110TempSensorCount -- MIB Release 3.00.11 03/01/01 - Added CPSMP110 Table -- MIB Release 3.00.10 02/14/01 - Added CSDTF100 Table -- MIB Release 3.00.09 01/15/01 - Added Cpsmc1300 13 slot chassis table type -- MIB Release 3.00.08 12/15/00 - Change comment on cpsmm100SNMPTrapInterval -- MIB Release 3.00.07 11/03/00 - Removed cgetf100RcvErrCnt -- MIB Release 3.00.06 11/01/00 - Add cpsmp100SupplyType -- MIB Release 3.00.05 10/31/00 - Add csetf100, cgetf100 -- MIB Release 3.00.04 09/15/00 - Change slotcps to slotCps, Add documentation, -- Remove cpsPSTable, Change FanICC to FanFault -- in cpsmp100, Make syntax for 'Enabled' vars -- more consistent. Make syntax for 'Signal' -- vars more consistent with 'Link' vars. -- Change CfgMatch value from inactive(3) to -- notApplicable(3). Change active(1) inactive(2) -- to yes(1) no(2) to improve consistency. -- MIB Release 3.00.03 08/14/00 - Removed cfetf100FarEndFault and added -- - cfetf100AutoCross entries -- MIB Release 3.00.02 07/27/00 - Added cpsIsPrimary -- MIB Release 3.00.01 07/17/00 - Added MRevision entries for cpsMc1800, -- cpsMc0800, cpsmm200, and cpsmm100 -- MIB Release 3.00 06/12/00 - CPSMC1800, CPSMM100, CFETF100, CFMFF100, -- CETTF100, CPSMP100, CPSMM200 added. -- MIB Release 2.07.1 11/10/99 - Remove extra comma from C/RS232-CF-01 -- MIB Release 2.07 09/22/99 - Add C/RS232-CF-01 -- MIB Release 2.06.6 09/10/99 - Remove extra comma from ceTbtFrl04 -- MIB Release 2.06.5 07/15/99 - Add ceTbtFrl04 -- MIB Release 2.06.4 06/26/99 - Add ceTxSx02 -- MIB Release 2.06.3 06/08/99 - Add mcc16ComNotes -- MIB Release 2.06.2 05/14/99 - Add chstrCf01 -- MIB Release 2.06.1 05/10/99 - Add ceRTxFx01 -- MIB Release 2.06 04/20/99 - Add ct1e1Cf01, mc20pDblWide -- MIB Release 2.05.1 01/26/99 - Add caCf02, cpsCf01, cbCf01, carCf01, carCf02 -- MIB Release 2.05 01/22/99 - Add cePswSx01 -- MIB Release 2.04.1 11/03/98 - OEM changes -- MIB Release 2.04 10/16/98 - cfSmMm06, cpsCf01, cePswFx03 -- MIB Release 2.03 09/18/98 - ce100BtxFx04, cePswFx03, ce100BtxSx01, -- ce100BtxFx04Mt, ERROR trap, ERROR CLEAR trap -- POWER SUPPLY STATUS CHANGE trap. -- Split MCC16 definitions from TNI.MIB. 2.03 -- is the initial release of MCC16-MIB. -- -- All of the above release description comments -- list items ADDED unless otherwise noted. -- -- Copyright (c) 1996-2000 Transition Networks, Inc. All Rights Reserved. -- -- Reproduction of this document is authorized on condition that -- this copyright notice is included. This Transition Networks, Inc. -- SNMP Management Information Base Specification (MCC-16-MIB) embodies -- T.N.I.'s confidential and proprietary intellectual property. -- T.N.I. retains all title and ownership in the MCC16-MIB Specification, -- including any revisions. -- -- It is T.N.I.'s intent to encourage the widespread use of this -- specification in connection with the management of Transition -- Networks, Inc.'s products. T.N.I. grants vendor, end-users, -- and other interested parties a non-exclusive license to use this -- specification in connection with the management of Transition -- Networks, Inc.'s products. -- -- This MCC16-MIB Specification is supplied "AS IS," and T.N.I. makes -- no warranty, either express or implied, as to the use, -- operation, condition, or performance of the MCC16-MIB Specification. -- -- T.N.I. retains the right to change this MCC16-MIB without notification. --get=cgfeb100entry -- RESUME OEM EDITING MCC16-MIB DEFINITIONS ::= BEGIN -- -- SECTION 1: Top Level Definitions -- -- -- Imports -- IMPORTS enterprises, Gauge, TimeTicks, IpAddress FROM RFC1155-SMI DisplayString, PhysAddress FROM RFC1213-MIB OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215; MacAddress ::= OCTET STRING (SIZE (6)) -- a 6 octet address in the "canonical" order defined by IEEE -- 802.1a, i.e., as if it were transmitted least significant bit -- first, even though 802.5 (in contrast to other 802.x protocols) -- requires MAC addresses to be transmitted most significant bit -- first. 16-bit addresses, if needed, are represented by setting -- their upper 4 octets to all 0's, i.e., AAFF would be -- represented as 00000000AAFF. -- The types of connectors that can be built into a Point System converter. -- No type of converter uses all of these connector types. -- Some converters return 16 bit connector style values that contain additional -- information on the connector in the upper byte. In these cases, the lower -- byte is one of the values below. CpsConnector ::= INTEGER { rj-45(10), -- RJ-45, unshielded twisted pair stmm(11), -- ST fiber, multimode stsm(12), -- ST fiber, singlemode scmm(13), -- SC fiber, multimode scsm(14), -- SC fiber, singlemode scsmlh(15), -- SC fiber, singlemode, long haul scsmelh(16), -- SC fiber, singlemode, extra long haul scsmlhlw(17), -- SC fiber, long haul, long wavelength mtrjmm(18), -- MT-RJ multimode fiber lc(19), -- LC fiber, singlemode bnc(20), -- BNC coax stsmlh(21), -- ST Singlemode Long Haul stsmelh(22), -- ST Singlemode Extra Long Haul scmm1300(23), -- SC Multimode 1300nm stmm1300(24), -- ST Multimode 1300nm mtrjsm(25), -- MTRJ singlemode fiber serial26(26), -- Universal 26-pin Serial Interface Connector stmmlh(27), -- ST Multimode Long Haul scsmsh(28), -- SC Singlemode Short Haul scsimplex(29), -- SC Simplex bncdual(30), -- Dual BNC coax connectors db9rsxxx(31), -- DB9 for RS232 and RS485 termblock(32), -- Terminal Block for RS485 rj11(33), -- RJ-11, unshielded twisted pair sc40km(34), -- SC fiber, 1550nm 40km sc125km(35) -- SC fiber, 1 x 9, 125km Gigiabit } -- -- Categories -- transition OBJECT IDENTIFIER ::= { enterprises 868 } productId OBJECT IDENTIFIER ::= { transition 1 } -- {productId 1 through 3} are reserved chassisProdsId OBJECT IDENTIFIER ::= { productId 4 } chassisSlotTypes OBJECT IDENTIFIER ::= { chassisProdsId 1 } chSlMc20p OBJECT IDENTIFIER ::= { chassisSlotTypes 1 } chSlcps OBJECT IDENTIFIER ::= { chassisSlotTypes 2 } chassisMcc16Id OBJECT IDENTIFIER ::= { chassisProdsId 2 } products OBJECT IDENTIFIER ::= { transition 2 } -- These are identifying OIDs for devices that can be inserted into -- a 20 pin media converter chassis slot, i.e. an MCC 16: ceTbtFrl03Id OBJECT IDENTIFIER ::= { chSlMc20p 1 } ceCxTbt04Id OBJECT IDENTIFIER ::= { chSlMc20p 2 } ceCxFrl04Id OBJECT IDENTIFIER ::= { chSlMc20p 3 } cfSmMm02Id OBJECT IDENTIFIER ::= { chSlMc20p 4 } cfSmMm05Id OBJECT IDENTIFIER ::= { chSlMc20p 5 } caCf02Id OBJECT IDENTIFIER ::= { chSlMc20p 6 } cfSmMm06Id OBJECT IDENTIFIER ::= { chSlMc20p 7 } ct1e1Cf01Id OBJECT IDENTIFIER ::= { chSlMc20p 8 } ceRTxFx01Id OBJECT IDENTIFIER ::= { chSlMc20p 9 } ce100BtxFx04Id OBJECT IDENTIFIER ::= { chSlMc20p 10 } cpsCf01Id OBJECT IDENTIFIER ::= { chSlMc20p 12 } cbCf01Id OBJECT IDENTIFIER ::= { chSlMc20p 13 } carCf01Id OBJECT IDENTIFIER ::= { chSlMc20p 14 } carCf02Id OBJECT IDENTIFIER ::= { chSlMc20p 15 } cePswFx03Id OBJECT IDENTIFIER ::= { chSlMc20p 16 } cePswSx01Id OBJECT IDENTIFIER ::= { chSlMc20p 17 } cRs232Cf01Id OBJECT IDENTIFIER ::= { chSlMc20p 18 } cfSmMm04Id OBJECT IDENTIFIER ::= { chSlMc20p 24 } ce100BtxSx01Id OBJECT IDENTIFIER ::= { chSlMc20p 26 } ce100BtxFx04MtId OBJECT IDENTIFIER ::= { chSlMc20p 27 } cfdCd01Id OBJECT IDENTIFIER ::= { chSlMc20p 28 } ctrCf01Id OBJECT IDENTIFIER ::= { chSlMc20p 29 } ce100BtxFrl03Id OBJECT IDENTIFIER ::= { chSlMc20p 30 } mc20pEmptyId OBJECT IDENTIFIER ::= { chSlMc20p 31 } -- this means that the ID bits that were seen were invalid. mc20pErrorId OBJECT IDENTIFIER ::= { chSlMc20p 32 } mc20pDblWideId OBJECT IDENTIFIER ::= { chSlMc20p 33 } chstrCf01Id OBJECT IDENTIFIER ::= { chSlMc20p 34 } ceTxSx02Id OBJECT IDENTIFIER ::= { chSlMc20p 35 } ceTbtFrl04Id OBJECT IDENTIFIER ::= { chSlMc20p 36 } -- These are identifying OIDs for devices that can be inserted -- into a chassis 2 i2c slot: cpsmM100Id OBJECT IDENTIFIER ::= { chSlcps 1 } cpsmM200Id OBJECT IDENTIFIER ::= { chSlcps 2 } cettf100Id OBJECT IDENTIFIER ::= { chSlcps 3 } cfetf100Id OBJECT IDENTIFIER ::= { chSlcps 4 } cfmff100Id OBJECT IDENTIFIER ::= { chSlcps 5 } cpsmp100Id OBJECT IDENTIFIER ::= { chSlcps 6 } csetf100Id OBJECT IDENTIFIER ::= { chSlcps 7 } cgetf100Id OBJECT IDENTIFIER ::= { chSlcps 8 } csdtf100Id OBJECT IDENTIFIER ::= { chSlcps 9 } cpsmp110Id OBJECT IDENTIFIER ::= { chSlcps 10 } cbftf100Id OBJECT IDENTIFIER ::= { chSlcps 11 } cetct100Id OBJECT IDENTIFIER ::= { chSlcps 12 } ccscf100Id OBJECT IDENTIFIER ::= { chSlcps 13 } cfetf105Id OBJECT IDENTIFIER ::= { chSlcps 14 } smacf100PId OBJECT IDENTIFIER ::= { chSlcps 15 } cpsld100Id OBJECT IDENTIFIER ::= { chSlcps 16 } cdftf100Id OBJECT IDENTIFIER ::= { chSlcps 17 } cpsvt100Id OBJECT IDENTIFIER ::= { chSlcps 18 } cemtf100Id OBJECT IDENTIFIER ::= { chSlcps 19 } captf100Id OBJECT IDENTIFIER ::= { chSlcps 20 } cfetf205Id OBJECT IDENTIFIER ::= { chSlcps 21 } cbftf150Id OBJECT IDENTIFIER ::= { chSlcps 22 } cgfeb100Id OBJECT IDENTIFIER ::= { chSlcps 23 } crmfe100Id OBJECT IDENTIFIER ::= { chSlcps 24 } crs2f100Id OBJECT IDENTIFIER ::= { chSlcps 25 } crs4f100Id OBJECT IDENTIFIER ::= { chSlcps 26 } cmefg100Id OBJECT IDENTIFIER ::= { chSlcps 27 } cpsEmptyId OBJECT IDENTIFIER ::= { chSlcps 1001 } cpsDblWideId OBJECT IDENTIFIER ::= { chSlcps 1002 } cpsUnknownDeviceId OBJECT IDENTIFIER ::= { chSlcps 1003 } -- {products 1 through 3} are reserved -- chassis: chassis products chassis OBJECT IDENTIFIER ::= { products 4 } -- card: devices that plug in to a device listed under backplane(2) card OBJECT IDENTIFIER ::= { chassis 1 } -- slotMc20p: devices that plug into 20 pin media converter slot slotMc20p OBJECT IDENTIFIER ::= { card 1 } -- slotCps: devices that plug into Point System i2c slots slotCps OBJECT IDENTIFIER ::= { card 2 } -- backplane: devices that have slots to accept devices listed under card(1), -- or are the functional equivalent of such a device. backplane OBJECT IDENTIFIER ::= { chassis 2 } mcc16 OBJECT IDENTIFIER ::= { backplane 1 } mcc16Common OBJECT IDENTIFIER ::= { mcc16 1 } mcc16Ver1 OBJECT IDENTIFIER ::= { mcc16 2 } cps OBJECT IDENTIFIER ::= { backplane 2 } cpsSlotSummary OBJECT IDENTIFIER ::= { slotCps 1 } -- cpsSlotDetail: the details of a Point System media converter, -- management module or power supply cpsSlotDetail OBJECT IDENTIFIER ::= { slotCps 2 } chassisCpsmc1800Id OBJECT IDENTIFIER ::= { chassisProdsId 3 } chassisCpsmc1850Id OBJECT IDENTIFIER ::= { chassisProdsId 4 } chassisCpsmc0800Id OBJECT IDENTIFIER ::= { chassisProdsId 5 } chassisCpsmc1300Id OBJECT IDENTIFIER ::= { chassisProdsId 6 } chassisCpsmc0200Id OBJECT IDENTIFIER ::= { chassisProdsId 7 } chassisSmacf100LCId OBJECT IDENTIFIER ::= { chassisProdsId 8 } chassisCpsmc1900Id OBJECT IDENTIFIER ::= { chassisProdsId 9 } chassisSmacf100Id OBJECT IDENTIFIER ::= { chassisProdsId 10 } cpsCabSummary OBJECT IDENTIFIER ::= { cps 1 } cpsCabDetail OBJECT IDENTIFIER ::= { cps 2 } cpsAgent OBJECT IDENTIFIER ::= { cps 3 } -- ================================================================== -- -- SECTION 2: -- -- Definitions for chassis based products. -- First, the plug-in devices, then the chassis. -- ================================================================== -- ================================================================== -- Table for C/E-TBT-FRL-03 media converters in a media converter chassis. ceTbtFrl03Table OBJECT-TYPE SYNTAX SEQUENCE OF CeTbtFrl03Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/E-TBT-FRL-03 media converter, then entry 'n' in this table exists and describes the state of the converter's LEDs If slot 'n' is empty, does not exist, or contains a different type of device, then table entry 'n' does not exist." ::= { slotMc20p 1 } ceTbtFrl03Entry OBJECT-TYPE SYNTAX CeTbtFrl03Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "State of LEDs on a single C/E-TBT-FRL-03" INDEX { ceTbtFrl03Index } ::= { ceTbtFrl03Table 1 } CeTbtFrl03Entry ::= SEQUENCE { ceTbtFrl03Index INTEGER, ceTbtFrl03FiberRecv INTEGER, ceTbtFrl03FiberLink INTEGER, ceTbtFrl03TPRecv INTEGER, ceTbtFrl03TPLink INTEGER, ceTbtFrl03Power INTEGER } ceTbtFrl03Index OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of a slot in a media converter chassis" ::= { ceTbtFrl03Entry 1 } ceTbtFrl03FiberRecv OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Fiber Receive LED" ::= { ceTbtFrl03Entry 2 } ceTbtFrl03FiberLink OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Fiber Link LED" ::= { ceTbtFrl03Entry 3 } ceTbtFrl03TPRecv OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Twisted Pair Receive LED" ::= { ceTbtFrl03Entry 4 } ceTbtFrl03TPLink OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Twisted Pair Link LED" ::= { ceTbtFrl03Entry 5 } ceTbtFrl03Power OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Power LED" ::= { ceTbtFrl03Entry 6 } -- ================================================================== -- Table for C/E-CX-TBT-04 media converters in a media converter chassis. ceCxTbt04Table OBJECT-TYPE SYNTAX SEQUENCE OF CeCxTbt04Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/E-CX-TBT-04 media converter, then entry 'n' in this table exists and describes the state of the converter's LEDs If slot 'n' is empty, does not exist, or contains a different type of device, then table entry 'n' does not exist." ::= { slotMc20p 2 } ceCxTbt04Entry OBJECT-TYPE SYNTAX CeCxTbt04Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "State of LEDs on a single C/E-CX-TBT-04" INDEX { ceCxTbt04Index } ::= { ceCxTbt04Table 1 } CeCxTbt04Entry ::= SEQUENCE { ceCxTbt04Index INTEGER, ceCxTbt04Jabber INTEGER, ceCxTbt04CoaxRecv INTEGER, ceCxTbt04TPRecv INTEGER, ceCxTbt04TPLink INTEGER, ceCxTbt04Power INTEGER } ceCxTbt04Index OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of a slot in a media converter chassis" ::= { ceCxTbt04Entry 1 } ceCxTbt04Jabber OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Jabber LED" ::= { ceCxTbt04Entry 2 } ceCxTbt04CoaxRecv OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's CoaxRecv LED" ::= { ceCxTbt04Entry 3 } ceCxTbt04TPRecv OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's TPRecv LED" ::= { ceCxTbt04Entry 4 } ceCxTbt04TPLink OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's TPLink LED" ::= { ceCxTbt04Entry 5 } ceCxTbt04Power OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Power LED" ::= { ceCxTbt04Entry 6 } -- ================================================================== -- Table for C/E-CX-FRL-04 media converters in a media converter chassis. ceCxFrl04Table OBJECT-TYPE SYNTAX SEQUENCE OF CeCxFrl04Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/E-CX-FRL-04 media converter, then entry 'n' in this table exists and describes the state of the converter's LEDs If slot 'n' is empty, does not exist, or contains a different type of device, then table entry 'n' does not exist." ::= { slotMc20p 3 } ceCxFrl04Entry OBJECT-TYPE SYNTAX CeCxFrl04Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "State of LEDs on a single C/E-CX-FRL-04" INDEX { ceCxFrl04Index } ::= { ceCxFrl04Table 1 } CeCxFrl04Entry ::= SEQUENCE { ceCxFrl04Index INTEGER, ceCxFrl04Jabber INTEGER, ceCxFrl04CoaxRecv INTEGER, ceCxFrl04FLRecv INTEGER, ceCxFrl04FLLink INTEGER, ceCxFrl04Power INTEGER } ceCxFrl04Index OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of a slot in a media converter chassis" ::= { ceCxFrl04Entry 1 } ceCxFrl04Jabber OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Jabber LED" ::= { ceCxFrl04Entry 2 } ceCxFrl04CoaxRecv OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's CoaxRecv LED" ::= { ceCxFrl04Entry 3 } ceCxFrl04FLRecv OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's FLRecv LED" ::= { ceCxFrl04Entry 4 } ceCxFrl04FLLink OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's FLLink LED" ::= { ceCxFrl04Entry 5 } ceCxFrl04Power OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Power LED" ::= { ceCxFrl04Entry 6 } -- ================================================================== -- Table for C/F-SM-MM-02 media converters in a media converter chassis. cfSmMm02Table OBJECT-TYPE SYNTAX SEQUENCE OF CfSmMm02Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/F-SM-MM-02 media converter, then entry 'n' in this table exists and describes the state of the converter's LEDs If slot 'n' is empty, does not exist, or contains a different type of device, then table entry 'n' does not exist." ::= { slotMc20p 4 } cfSmMm02Entry OBJECT-TYPE SYNTAX CfSmMm02Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "State of LEDs on a single C/F-SM-MM-02" INDEX { cfSmMm02Index } ::= { cfSmMm02Table 1 } CfSmMm02Entry ::= SEQUENCE { cfSmMm02Index INTEGER, cfSmMm02MMSignalDetect INTEGER, cfSmMm02SMSignalDetect INTEGER, cfSmMm02Power INTEGER } cfSmMm02Index OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of a slot in a media converter chassis" ::= { cfSmMm02Entry 1 } cfSmMm02MMSignalDetect OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's MMSignalDetect LED" ::= { cfSmMm02Entry 2 } cfSmMm02SMSignalDetect OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's SMSignalDetect LED" ::= { cfSmMm02Entry 3 } cfSmMm02Power OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Power LED" ::= { cfSmMm02Entry 4 } -- ================================================================== -- Table for C/F-SM-MM-05 media converters in a media converter chassis. cfSmMm05Table OBJECT-TYPE SYNTAX SEQUENCE OF CfSmMm05Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/F-SM-MM-05 media converter, then entry 'n' in this table exists and describes the state of the converter's LEDs If slot 'n' is empty, does not exist, or contains a different type of device, then table entry 'n' does not exist." ::= { slotMc20p 5 } cfSmMm05Entry OBJECT-TYPE SYNTAX CfSmMm05Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "State of LEDs on a single C/F-SM-MM-05" INDEX { cfSmMm05Index } ::= { cfSmMm05Table 1 } CfSmMm05Entry ::= SEQUENCE { cfSmMm05Index INTEGER, cfSmMm05SMSignalDetect INTEGER, cfSmMm05MMSignalDetect INTEGER, cfSmMm05Power INTEGER } cfSmMm05Index OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of a slot in a media converter chassis" ::= { cfSmMm05Entry 1 } cfSmMm05SMSignalDetect OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's SMSignalDetect LED" ::= { cfSmMm05Entry 2 } cfSmMm05MMSignalDetect OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's MMSignalDetect LED" ::= { cfSmMm05Entry 3} cfSmMm05Power OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Power LED" ::= { cfSmMm05Entry 4 } -- ================================================================== -- Table for C/A-CF-02 media converters in a media converter chassis. caCf02Table OBJECT-TYPE SYNTAX SEQUENCE OF CaCf02Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/A-CF-02 media converter, then entry 'n' in this table exists and describes the state of the converter's LEDs If slot 'n' is empty, does not exist, or contains a different type of device, then table entry 'n' does not exist." ::= { slotMc20p 6 } caCf02Entry OBJECT-TYPE SYNTAX CaCf02Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "State of LEDs on a single C/A-CF-02" INDEX { caCf02Index } ::= { caCf02Table 1 } CaCf02Entry ::= SEQUENCE { caCf02Index INTEGER, caCf02CopperSignalDetect INTEGER, caCf02FiberSignalDetect INTEGER, caCf02Power INTEGER } caCf02Index OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of a slot in a media converter chassis" ::= { caCf02Entry 1 } caCf02CopperSignalDetect OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's CopperSignalDetect LED" ::= { caCf02Entry 2 } caCf02FiberSignalDetect OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's FiberSignalDetect LED" ::= { caCf02Entry 3 } caCf02Power OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Power LED" ::= { caCf02Entry 4 } -- ================================================================== -- Table for C/F-SM-MM-06 media converters in a media converter chassis. cfSmMm06Table OBJECT-TYPE SYNTAX SEQUENCE OF CfSmMm06Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/F-SM-MM-06 media converter, then entry 'n' in this table exists and describes the state of the converter's LEDs If slot 'n' is empty, does not exist, or contains a different type of device, then table entry 'n' does not exist." ::= { slotMc20p 7 } cfSmMm06Entry OBJECT-TYPE SYNTAX CfSmMm06Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "State of LEDs on a single C/F-SM-MM-06" INDEX { cfSmMm06Index } ::= { cfSmMm06Table 1 } CfSmMm06Entry ::= SEQUENCE { cfSmMm06Index INTEGER, cfSmMm06MMSignalDetect INTEGER, cfSmMm06SMSignalDetect INTEGER, cfSmMm06Power INTEGER } cfSmMm06Index OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of a slot in a media converter chassis" ::= { cfSmMm06Entry 1 } cfSmMm06MMSignalDetect OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's MMSignalDetect LED" ::= { cfSmMm06Entry 2 } cfSmMm06SMSignalDetect OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's SMSignalDetect LED" ::= { cfSmMm06Entry 3 } cfSmMm06Power OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Power LED" ::= { cfSmMm06Entry 4 } -- ================================================================== -- Table for C/T1E1-CF-01 media converters in a media converter chassis. ct1e1Cf01Table OBJECT-TYPE SYNTAX SEQUENCE OF Ct1e1Cf01Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/T1E1-CF-01 media converter, then entry 'n' in this table exists and describes the state of the converter's LEDs If slot 'n' is empty, does not exist, or contains a different type of device, then table entry 'n' does not exist." ::= { slotMc20p 8 } ct1e1Cf01Entry OBJECT-TYPE SYNTAX Ct1e1Cf01Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "State of LEDs on a single C/T1E1-CF-01" INDEX { ct1e1Cf01Index } ::= { ct1e1Cf01Table 1 } Ct1e1Cf01Entry ::= SEQUENCE { ct1e1Cf01Index INTEGER, ct1e1Cf01CopperSignalDetect INTEGER, ct1e1Cf01FiberSignalDetect INTEGER, ct1e1Cf01CoaxActive INTEGER } ct1e1Cf01Index OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of a slot in a media converter chassis" ::= { ct1e1Cf01Entry 1 } ct1e1Cf01CopperSignalDetect OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's CopperSignalDetect LED" ::= { ct1e1Cf01Entry 2 } ct1e1Cf01FiberSignalDetect OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's FiberSignalDetect LED" ::= { ct1e1Cf01Entry 3 } ct1e1Cf01CoaxActive OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Coax Active LED" ::= { ct1e1Cf01Entry 4 } -- ================================================================== -- Table for C/E-R-TX-FX-01 media converters in a media converter chassis. ceRTxFx01Table OBJECT-TYPE SYNTAX SEQUENCE OF CeRTxFx01Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/E-R-TX-FX-01 media converter, then entry 'n' in this table exists and describes the state of the converter's LEDs If slot 'n' is empty, does not exist, or contains a different type of device, then table entry 'n' does not exist." ::= { slotMc20p 9 } ceRTxFx01Entry OBJECT-TYPE SYNTAX CeRTxFx01Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "State of LEDs on a single C/E-R-TX-FX-01" INDEX { ceRTxFx01Index } ::= { ceRTxFx01Table 1 } CeRTxFx01Entry ::= SEQUENCE { ceRTxFx01Index INTEGER, ceRTxFx01TPPrimary INTEGER, ceRTxFx01FiberPrimary INTEGER, ceRTxFx01TPSignalDetect INTEGER, ceRTxFx01FiberSignalDetect INTEGER } ceRTxFx01Index OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of a slot in a media converter chassis" ::= { ceRTxFx01Entry 1 } ceRTxFx01TPPrimary OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Twisted Pair Primary LED" ::= { ceRTxFx01Entry 2 } ceRTxFx01FiberPrimary OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Fiber Primary LED" ::= { ceRTxFx01Entry 3 } ceRTxFx01TPSignalDetect OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Twisted Pair Signal Detect LED" ::= { ceRTxFx01Entry 4 } ceRTxFx01FiberSignalDetect OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Fiber Signal Detect LED" ::= { ceRTxFx01Entry 5 } -- ================================================================== -- Table for C/E-100-BTX-FX-04(ST/SC) media converters in a media -- converter chassis. ce100BtxFx04Table OBJECT-TYPE SYNTAX SEQUENCE OF Ce100BtxFx04Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/E-100-BTX-FX-04(ST/SC) media converter, then entry 'n' in this table exists and describes the state of the converter's LEDs If slot 'n' is empty, does not exist, or contains a different type of device, then table entry 'n' does not exist." ::= { slotMc20p 10 } ce100BtxFx04Entry OBJECT-TYPE SYNTAX Ce100BtxFx04Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "State of LEDs on a single C/E-100-BTX-FX-04(ST/SC)" INDEX { ce100BtxFx04Index } ::= { ce100BtxFx04Table 1 } Ce100BtxFx04Entry ::= SEQUENCE { ce100BtxFx04Index INTEGER, ce100BtxFx04TPRecv INTEGER, ce100BtxFx04FiberRecv INTEGER, ce100BtxFx04TPSignalDetect INTEGER, ce100BtxFx04FiberSignalDetect INTEGER, ce100BtxFx04Power INTEGER } ce100BtxFx04Index OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of a slot in a media converter chassis" ::= { ce100BtxFx04Entry 1 } ce100BtxFx04TPRecv OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Twisted Pair Receive LED" ::= { ce100BtxFx04Entry 2 } ce100BtxFx04FiberRecv OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Fiber Receive LED" ::= { ce100BtxFx04Entry 3 } ce100BtxFx04TPSignalDetect OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Twisted Pair signal detect LED" ::= { ce100BtxFx04Entry 4 } ce100BtxFx04FiberSignalDetect OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's fiber signal detect LED" ::= { ce100BtxFx04Entry 5 } ce100BtxFx04Power OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Power LED" ::= { ce100BtxFx04Entry 6 } -- ================================================================== -- Table for C/PS-CF-01 media converters in a media -- converter chassis. -- Note that the first three letters of this name DO NOT indicate -- that this device is in any way related to the Point System. It -- is an MCC16-only device. The naming is an unfortunate coincidence. cpsCf01Table OBJECT-TYPE SYNTAX SEQUENCE OF CpsCf01Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/PS-CF-01 media converter, then entry 'n' in this table exists and describes the state of the converter's LEDs If slot 'n' is empty, does not exist, or contains a different type of device, then table entry 'n' does not exist." ::= { slotMc20p 12 } cpsCf01Entry OBJECT-TYPE SYNTAX CpsCf01Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "State of LEDs on a single C/PS-CF-01" INDEX { cpsCf01Index } ::= { cpsCf01Table 1 } CpsCf01Entry ::= SEQUENCE { cpsCf01Index INTEGER, cpsCf01FiberRecv INTEGER, cpsCf01TPRecv INTEGER, cpsCf01Power INTEGER } cpsCf01Index OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of a slot in a media converter chassis" ::= { cpsCf01Entry 1 } cpsCf01FiberRecv OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Fiber Receive LED" ::= { cpsCf01Entry 2 } cpsCf01TPRecv OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Twisted Pair Receive LED" ::= { cpsCf01Entry 3 } cpsCf01Power OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Power LED" ::= { cpsCf01Entry 4 } -- ================================================================== -- Table for C/B-CF-01 media converters in a media -- converter chassis. cbCf01Table OBJECT-TYPE SYNTAX SEQUENCE OF CbCf01Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/B-CF-01 media converter, then entry 'n' in this table exists and describes the state of the converter's LEDs If slot 'n' is empty, does not exist, or contains a different type of device, then table entry 'n' does not exist." ::= { slotMc20p 13 } cbCf01Entry OBJECT-TYPE SYNTAX CbCf01Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "State of LEDs on a single C/B-CF-01" INDEX { cbCf01Index } ::= { cbCf01Table 1 } CbCf01Entry ::= SEQUENCE { cbCf01Index INTEGER, cbCf01FiberRecv INTEGER, cbCf01TPCoaxRecv INTEGER, cbCf01Power INTEGER } cbCf01Index OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of a slot in a media converter chassis" ::= { cbCf01Entry 1 } cbCf01FiberRecv OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Fiber Receive LED" ::= { cbCf01Entry 2 } cbCf01TPCoaxRecv OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Twisted Pair/Coax Receive LED" ::= { cbCf01Entry 3 } cbCf01Power OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Power LED" ::= { cbCf01Entry 4 } -- ================================================================== -- Table for C/AR-CF-01 media converters in a media -- converter chassis. carCf01Table OBJECT-TYPE SYNTAX SEQUENCE OF CarCf01Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/AR-CF-01 media converter, then entry 'n' in this table exists and describes the state of the converter's LEDs If slot 'n' is empty, does not exist, or contains a different type of device, then table entry 'n' does not exist." ::= { slotMc20p 14 } carCf01Entry OBJECT-TYPE SYNTAX CarCf01Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "State of LEDs on a single C/AR-CF-01" INDEX { carCf01Index } ::= { carCf01Table 1 } CarCf01Entry ::= SEQUENCE { carCf01Index INTEGER, carCf01FiberRecv INTEGER, carCf01TPRecv INTEGER, carCf01Power INTEGER } carCf01Index OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of a slot in a media converter chassis" ::= { carCf01Entry 1 } carCf01FiberRecv OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Fiber Receive LED" ::= { carCf01Entry 2 } carCf01TPRecv OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Twisted Pair Receive LED" ::= { carCf01Entry 3 } carCf01Power OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Power LED" ::= { carCf01Entry 4 } -- ================================================================== -- Table for C/AR-CF-02 media converters in a media -- converter chassis. carCf02Table OBJECT-TYPE SYNTAX SEQUENCE OF CarCf02Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/AR-CF-02 media converter, then entry 'n' in this table exists and describes the state of the converter's LEDs If slot 'n' is empty, does not exist, or contains a different type of device, then table entry 'n' does not exist." ::= { slotMc20p 15 } carCf02Entry OBJECT-TYPE SYNTAX CarCf02Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "State of LEDs on a single C/AR-CF-02" INDEX { carCf02Index } ::= { carCf02Table 1 } CarCf02Entry ::= SEQUENCE { carCf02Index INTEGER, carCf02FiberRecv INTEGER, carCf02CoaxRecv INTEGER, carCf02Power INTEGER } carCf02Index OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of a slot in a media converter chassis" ::= { carCf02Entry 1 } carCf02FiberRecv OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Fiber Receive LED" ::= { carCf02Entry 2 } carCf02CoaxRecv OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Coax Receive LED" ::= { carCf02Entry 3 } carCf02Power OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Power LED" ::= { carCf02Entry 4 } -- ================================================================== -- Table for C/E-PSW-FX-03 ethernet switch in a media converter chassis. cePswFx03Table OBJECT-TYPE SYNTAX SEQUENCE OF CePswFx03Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/E-PSW-FX-03 ethernet switch, then entry 'n' in this table exists and describes the state of the switch's LEDs If slot 'n' is empty, does not exist, or contains a different type of device, then table entry 'n' does not exist." ::= { slotMc20p 16 } cePswFx03Entry OBJECT-TYPE SYNTAX CePswFx03Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "State of LEDs on a single C/E-PSW-FX-03" INDEX { cePswFx03Index } ::= { cePswFx03Table 1 } CePswFx03Entry ::= SEQUENCE { cePswFx03Index INTEGER, cePswFx03TPFullDuplex INTEGER, cePswFx03FiberFullDuplex INTEGER, cePswFx03TPLink INTEGER, cePswFx03FiberLink INTEGER, cePswFx03TP100Mbps INTEGER } cePswFx03Index OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of a slot in a media converter chassis" ::= { cePswFx03Entry 1 } cePswFx03TPFullDuplex OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Twisted Pair FDX LED" ::= { cePswFx03Entry 2 } cePswFx03FiberFullDuplex OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Fiber FDX LED" ::= { cePswFx03Entry 3 } cePswFx03TPLink OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Twisted Pair Link LED" ::= { cePswFx03Entry 4 } cePswFx03FiberLink OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Fiber Link LED" ::= { cePswFx03Entry 5 } cePswFx03TP100Mbps OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Twisted Pair 100Mbps LED" ::= { cePswFx03Entry 6 } -- ================================================================== -- Table for C/E-PSW-SX-01 ethernet switch in a media converter chassis. cePswSx01Table OBJECT-TYPE SYNTAX SEQUENCE OF CePswSx01Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/E-PSW-SX-01 ethernet switch, then entry 'n' in this table exists and describes the state of the switch's LEDs If slot 'n' is empty, does not exist, or contains a different type of device, then table entry 'n' does not exist." ::= { slotMc20p 17 } cePswSx01Entry OBJECT-TYPE SYNTAX CePswSx01Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "State of LEDs on a single C/E-PSW-SX-01" INDEX { cePswSx01Index } ::= { cePswSx01Table 1 } CePswSx01Entry ::= SEQUENCE { cePswSx01Index INTEGER, cePswSx01TPFullDuplex INTEGER, cePswSx01FiberFullDuplex INTEGER, cePswSx01TPLink INTEGER, cePswSx01FiberLink INTEGER, cePswSx01TP100Mbps INTEGER } cePswSx01Index OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of a slot in a media converter chassis" ::= { cePswSx01Entry 1 } cePswSx01TPFullDuplex OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Twisted Pair FDX LED" ::= { cePswSx01Entry 2 } cePswSx01FiberFullDuplex OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Fiber FDX LED" ::= { cePswSx01Entry 3 } cePswSx01TPLink OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Twisted Pair Link LED" ::= { cePswSx01Entry 4 } cePswSx01FiberLink OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Fiber Link LED" ::= { cePswSx01Entry 5 } cePswSx01TP100Mbps OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Twisted Pair 100Mbps LED" ::= { cePswSx01Entry 6 } -- ================================================================== -- Table for C/RS232-CF-01 media converter in a media converter chassis. cRs232Cf01Table OBJECT-TYPE SYNTAX SEQUENCE OF CRs232Cf01Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/RS232-CF-01 media converter, then entry 'n' in this table exists and describes the state of the converter's LEDs If slot 'n' is empty, does not exist, or contains a different type of device, then table entry 'n' does not exist." ::= { slotMc20p 18 } cRs232Cf01Entry OBJECT-TYPE SYNTAX CRs232Cf01Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "State of LEDs on a single C/RS232-CF-01" INDEX { cRs232Cf01Index } ::= { cRs232Cf01Table 1 } CRs232Cf01Entry ::= SEQUENCE { cRs232Cf01Index INTEGER, cRs232Cf01FiberLock INTEGER } cRs232Cf01Index OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of a slot in a media converter chassis" ::= { cRs232Cf01Entry 1 } cRs232Cf01FiberLock OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Fiber Lock LED" ::= { cRs232Cf01Entry 2 } -- ================================================================== -- Table for C/F-SM-MM-04 media converters in a media converter chassis. cfSmMm04Table OBJECT-TYPE SYNTAX SEQUENCE OF CfSmMm04Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/F-SM-MM-04 media converter, then entry 'n' in this table exists and describes the state of the converter's LEDs If slot 'n' is empty, does not exist, or contains a different type of device, then table entry 'n' does not exist." ::= { slotMc20p 24 } cfSmMm04Entry OBJECT-TYPE SYNTAX CfSmMm04Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "State of LEDs on a single C/F-SM-MM-04" INDEX { cfSmMm04Index } ::= { cfSmMm04Table 1 } CfSmMm04Entry ::= SEQUENCE { cfSmMm04Index INTEGER, cfSmMm04MMSignalDetect INTEGER, cfSmMm04SMSignalDetect INTEGER, cfSmMm04Power INTEGER } cfSmMm04Index OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of a slot in a media converter chassis" ::= { cfSmMm04Entry 1 } cfSmMm04MMSignalDetect OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Multi-Mode signal detect LED" ::= { cfSmMm04Entry 2 } cfSmMm04SMSignalDetect OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Single-Mode signal detect LED" ::= { cfSmMm04Entry 3 } cfSmMm04Power OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Power LED" ::= { cfSmMm04Entry 4 } -- ================================================================== -- Table for C/E-100-BTX-SX-01 media converters in a media -- converter chassis. ce100BtxSx01Table OBJECT-TYPE SYNTAX SEQUENCE OF Ce100BtxSx01Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/E-100-BTX-SX-01 media converter, then entry 'n' in this table exists and describes the state of the converter's LEDs If slot 'n' is empty, does not exist, or contains a different type of device, then table entry 'n' does not exist." ::= { slotMc20p 26 } ce100BtxSx01Entry OBJECT-TYPE SYNTAX Ce100BtxSx01Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "State of LEDs on a single C/E-100-BTX-SX-01" INDEX { ce100BtxSx01Index } ::= { ce100BtxSx01Table 1 } Ce100BtxSx01Entry ::= SEQUENCE { ce100BtxSx01Index INTEGER, ce100BtxSx01TPRecv INTEGER, ce100BtxSx01FiberRecv INTEGER, ce100BtxSx01TPSignalDetect INTEGER, ce100BtxSx01FiberSignalDetect INTEGER, ce100BtxSx01Power INTEGER } ce100BtxSx01Index OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of a slot in a media converter chassis" ::= { ce100BtxSx01Entry 1 } ce100BtxSx01TPRecv OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Twisted Pair Receive LED" ::= { ce100BtxSx01Entry 2 } ce100BtxSx01FiberRecv OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Fiber Receive LED" ::= { ce100BtxSx01Entry 3 } ce100BtxSx01TPSignalDetect OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Twisted Pair signal detect LED" ::= { ce100BtxSx01Entry 4 } ce100BtxSx01FiberSignalDetect OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's fiber signal detect LED" ::= { ce100BtxSx01Entry 5 } ce100BtxSx01Power OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Power LED" ::= { ce100BtxSx01Entry 6 } -- ================================================================== -- Table for C/E-100-BTX-FX-04(MT) media converters in a media -- converter chassis. ce100BtxFx04MtTable OBJECT-TYPE SYNTAX SEQUENCE OF Ce100BtxFx04MtEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/E-100-BTX-FX-04(MT) media converter, then entry 'n' in this table exists and describes the state of the converter's LEDs If slot 'n' is empty, does not exist, or contains a different type of device, then table entry 'n' does not exist." ::= { slotMc20p 27 } ce100BtxFx04MtEntry OBJECT-TYPE SYNTAX Ce100BtxFx04MtEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "State of LEDs on a single C/E-100-BTX-FX-04(MT)" INDEX { ce100BtxFx04MtIndex } ::= { ce100BtxFx04MtTable 1 } Ce100BtxFx04MtEntry ::= SEQUENCE { ce100BtxFx04MtIndex INTEGER, ce100BtxFx04MtTPRecv INTEGER, ce100BtxFx04MtFiberRecv INTEGER, ce100BtxFx04MtTPSignalDetect INTEGER, ce100BtxFx04MtFiberSignalDetect INTEGER, ce100BtxFx04MtPower INTEGER } ce100BtxFx04MtIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of a slot in a media converter chassis" ::= { ce100BtxFx04MtEntry 1 } ce100BtxFx04MtTPRecv OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Twisted Pair Receive LED" ::= { ce100BtxFx04MtEntry 2 } ce100BtxFx04MtFiberRecv OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Fiber Receive LED" ::= { ce100BtxFx04MtEntry 3 } ce100BtxFx04MtTPSignalDetect OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Twisted Pair signal detect LED" ::= { ce100BtxFx04MtEntry 4 } ce100BtxFx04MtFiberSignalDetect OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's fiber signal detect LED" ::= { ce100BtxFx04MtEntry 5 } ce100BtxFx04MtPower OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Power LED" ::= { ce100BtxFx04MtEntry 6 } -- ================================================================== -- Table for C/FD-CD-01 media converters in a media converter chassis. cfdCd01Table OBJECT-TYPE SYNTAX SEQUENCE OF CfdCd01Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/FD-CD-01 media converter, then entry 'n' in this table exists and describes the state of the converter's LEDs If slot 'n' is empty, does not exist, or contains a different type of device, then table entry 'n' does not exist." ::= { slotMc20p 28 } cfdCd01Entry OBJECT-TYPE SYNTAX CfdCd01Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "State of LEDs on a single C/FD-CD-01" INDEX { cfdCd01Index } ::= { cfdCd01Table 1 } CfdCd01Entry ::= SEQUENCE { cfdCd01Index INTEGER, cfdCd01Lock INTEGER, cfdCd01TPRecv INTEGER, cfdCd01FiberRecv INTEGER, cfdCd01TPSignalDetect INTEGER, cfdCd01FiberSignalDetect INTEGER } cfdCd01Index OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of a slot in a media converter chassis" ::= { cfdCd01Entry 1 } cfdCd01Lock OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Lock LED" ::= { cfdCd01Entry 2 } cfdCd01TPRecv OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's TPRecv LED" ::= { cfdCd01Entry 3 } cfdCd01FiberRecv OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's FiberRecv LED" ::= { cfdCd01Entry 4 } cfdCd01TPSignalDetect OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's TPSignalDetect LED" ::= { cfdCd01Entry 5 } cfdCd01FiberSignalDetect OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's FiberSignalDetect LED" ::= { cfdCd01Entry 6 } -- ================================================================== -- Table for C/TR-CF-01 media converters in a media converter chassis. ctrCf01Table OBJECT-TYPE SYNTAX SEQUENCE OF CtrCf01Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/TR-CF-01 media converter, then entry 'n' in this table exists and describes the state of the converter's LEDs If slot 'n' is empty, does not exist, or contains a different type of device, then table entry 'n' does not exist." ::= { slotMc20p 29 } ctrCf01Entry OBJECT-TYPE SYNTAX CtrCf01Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "State of LEDs on a single C/TR-CF-01" INDEX { ctrCf01Index } ::= { ctrCf01Table 1 } CtrCf01Entry ::= SEQUENCE { ctrCf01Index INTEGER, ctrCf01FiberinOK INTEGER, ctrCf01TPinOK INTEGER, ctrCf01Inserted INTEGER } ctrCf01Index OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of a slot in a media converter chassis" ::= { ctrCf01Entry 1 } ctrCf01FiberinOK OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's FiberinOK LED" ::= { ctrCf01Entry 2 } ctrCf01TPinOK OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's TPinOK LED" ::= { ctrCf01Entry 3 } ctrCf01Inserted OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Inserted LED" ::= { ctrCf01Entry 4 } -- ================================================================== -- Table for C/E-100BTX-FRL-03 media converters in a media converter chassis. ce100BtxFrl03Table OBJECT-TYPE SYNTAX SEQUENCE OF Ce100BtxFrl03Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/E-100BTX-FRL-03 media converter, then entry 'n' in this table exists and describes the state of the converter's LEDs If slot 'n' is empty, does not exist, or contains a different type of device, then table entry 'n' does not exist." ::= { slotMc20p 30 } ce100BtxFrl03Entry OBJECT-TYPE SYNTAX Ce100BtxFrl03Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "State of LEDs on a single C/E-100BTX-FRL-03" INDEX { ce100BtxFrl03Index } ::= { ce100BtxFrl03Table 1 } Ce100BtxFrl03Entry ::= SEQUENCE { ce100BtxFrl03Index INTEGER, ce100BtxFrl03Lock INTEGER, ce100BtxFrl03TPRecv INTEGER, ce100BtxFrl03FiberRecv INTEGER, ce100BtxFrl03TPSignalDetect INTEGER, ce100BtxFrl03FiberSignalDetect INTEGER } ce100BtxFrl03Index OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of a slot in a media converter chassis" ::= { ce100BtxFrl03Entry 1 } ce100BtxFrl03Lock OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's signal lock pin" ::= { ce100BtxFrl03Entry 2 } ce100BtxFrl03TPRecv OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Twisted pair receive LED" ::= { ce100BtxFrl03Entry 3 } ce100BtxFrl03FiberRecv OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Fiber Receive LED" ::= { ce100BtxFrl03Entry 4 } ce100BtxFrl03TPSignalDetect OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Twisted pair signal detect LED" ::= { ce100BtxFrl03Entry 5 } ce100BtxFrl03FiberSignalDetect OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Fiber signal detect LED" ::= { ce100BtxFrl03Entry 6 } -- ================================================================== -- Table for C/HSTR-CF-01 media converters in a media -- converter chassis. chstrCf01Table OBJECT-TYPE SYNTAX SEQUENCE OF ChstrCf01Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/HSTR-CF-01 media converter, then entry 'n' in this table exists and describes the state of the converter's LEDs If slot 'n' is empty, does not exist, or contains a different type of device, then table entry 'n' does not exist." ::= { slotMc20p 34} chstrCf01Entry OBJECT-TYPE SYNTAX ChstrCf01Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "State of LEDs on a single C/HSTR-CF-01" INDEX { chstrCf01Index } ::= { chstrCf01Table 1 } ChstrCf01Entry ::= SEQUENCE { chstrCf01Index INTEGER, chstrCf01TPRecv INTEGER, chstrCf01FiberRecv INTEGER, chstrCf01TPSignalDetect INTEGER, chstrCf01FiberSignalDetect INTEGER } chstrCf01Index OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of a slot in a media converter chassis" ::= { chstrCf01Entry 1 } chstrCf01TPRecv OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Twisted Pair Receive LED" ::= { chstrCf01Entry 2 } chstrCf01FiberRecv OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Fiber Receive LED" ::= { chstrCf01Entry 3 } chstrCf01TPSignalDetect OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Twisted Pair signal detect LED" ::= { chstrCf01Entry 4 } chstrCf01FiberSignalDetect OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's fiber signal detect LED" ::= { chstrCf01Entry 5 } -- ================================================================== -- Table for C/E-TX-SX-02 media converters in a media converter chassis. ceTxSx02Table OBJECT-TYPE SYNTAX SEQUENCE OF CeTxSx02Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/E-TX-SX-02 media converter, then entry 'n' in this table exists and describes the state of the converter's LEDs If slot 'n' is empty, does not exist, or contains a different type of device, then table entry 'n' does not exist." ::= { slotMc20p 35 } ceTxSx02Entry OBJECT-TYPE SYNTAX CeTxSx02Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "State of LEDs on a single C/E-TX-SX-02" INDEX { ceTxSx02Index } ::= { ceTxSx02Table 1 } CeTxSx02Entry ::= SEQUENCE { ceTxSx02Index INTEGER, ceTxSx02TPLink INTEGER, ceTxSx02FiberLink INTEGER, ceTxSx02100Mbps INTEGER } ceTxSx02Index OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of a slot in a media converter chassis" ::= { ceTxSx02Entry 1 } ceTxSx02TPLink OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Twisted Pair Link LED" ::= { ceTxSx02Entry 2 } ceTxSx02FiberLink OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Fiber Link LED" ::= { ceTxSx02Entry 3 } ceTxSx02100Mbps OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's 100 Megabit Per Second LED" ::= { ceTxSx02Entry 4 } -- ================================================================== -- Table for C/E-TBT-FRL-04 media converters in a media converter chassis. ceTbtFrl04Table OBJECT-TYPE SYNTAX SEQUENCE OF CeTbtFrl04Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/E-TBT-FRL-04 media converter, then entry 'n' in this table exists and describes the state of the converter's LEDs If slot 'n' is empty, does not exist, or contains a different type of device, then table entry 'n' does not exist." ::= { slotMc20p 36 } ceTbtFrl04Entry OBJECT-TYPE SYNTAX CeTbtFrl04Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "State of LEDs on a single C/E-TBT-FRL-04" INDEX { ceTbtFrl04Index } ::= { ceTbtFrl04Table 1 } CeTbtFrl04Entry ::= SEQUENCE { ceTbtFrl04Index INTEGER, ceTbtFrl04FiberRecv INTEGER, ceTbtFrl04FiberLink INTEGER, ceTbtFrl04TPRecv INTEGER, ceTbtFrl04TPLink INTEGER } ceTbtFrl04Index OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of a slot in a media converter chassis" ::= { ceTbtFrl04Entry 1 } ceTbtFrl04FiberRecv OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Fiber Receive LED" ::= { ceTbtFrl04Entry 2 } ceTbtFrl04FiberLink OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Fiber Link LED" ::= { ceTbtFrl04Entry 3 } ceTbtFrl04TPRecv OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Twisted Pair Receive LED" ::= { ceTbtFrl04Entry 4 } ceTbtFrl04TPLink OBJECT-TYPE SYNTAX INTEGER { on(1),off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the converter's Twisted Pair Link LED" ::= { ceTbtFrl04Entry 5 } -- ================================================================== -- ================================================================== -- ================================================================== -- ================================================================== -- End MCC16 Conversion Center entries -- Begin Point System entries -- ================================================================== -- ================================================================== -- ================================================================== -- ================================================================== -- Note: All tables indexed by BiaIndex 'c' and SlotIndex 's' are -- sparse tables, i.e. if there is no cabinet in the stack -- with serial number 'c' and/or there is no device installed in -- slot 's', then the entry indexed 'c.s' in the table does not -- exist. -- All tables indexed by BiaIndex 'c' are sparse tables, i.e. -- if there is no cabinet in the stack with serial number 'c', -- then the entry indexed 'c' in the table does not exist. -- ================================================================== cpsModuleTable OBJECT-TYPE SYNTAX SEQUENCE OF CpsModuleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table from which one can extract the model number of any device in the stack, given the serial number (BIA) of the cabinet and the slot number in which the device is installed." ::= { cpsSlotSummary 1 } cpsModuleEntry OBJECT-TYPE SYNTAX CpsModuleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The model number entry for a single device." INDEX { cpsModuleBiaIndex, cpsModuleSlotIndex } ::= { cpsModuleTable 1 } CpsModuleEntry ::= SEQUENCE { cpsModuleBiaIndex INTEGER, cpsModuleSlotIndex INTEGER, cpsModuleModel OBJECT IDENTIFIER } cpsModuleBiaIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number (BIA) of the cabinet in which the device is installed" ::= { cpsModuleEntry 1 } cpsModuleSlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The slot in which the device is installed" ::= { cpsModuleEntry 2 } cpsModuleModel OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The model number of the device. See OIDs under chSlcps" ::= { cpsModuleEntry 3 } -- ====================================================================== -- Table for cpsmm100 base management module -- -- NOTE: This device is referred to in marketing literature as CPSMM200 -- cpsmm100Table OBJECT-TYPE SYNTAX SEQUENCE OF Cpsmm100Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Sparse table containing one entry for each CPSMM100-200 and other CPSMM100-xxx Point System Base Management Module in the stack, indexed by cabinet serial number and slot." ::= { cpsSlotDetail 1 } cpsmm100Entry OBJECT-TYPE SYNTAX Cpsmm100Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Status and configuration entries for a single CPSMM100" INDEX { cpsmm100BiaIndex, cpsmm100SlotIndex } ::= { cpsmm100Table 1 } Cpsmm100Entry ::= SEQUENCE { cpsmm100BiaIndex INTEGER, cpsmm100SlotIndex INTEGER, cpsmm100Groups DisplayString, cpsmm100Reset INTEGER, cpsmm100SaveConfig INTEGER, cpsmm100HwRevision DisplayString, cpsmm100SwRevision DisplayString, cpsmm100IPAddress IpAddress, cpsmm100SubnetMask IpAddress, cpsmm100Gateway IpAddress, cpsmm100IsPrimary INTEGER, cpsmm100WantPrimary INTEGER, cpsmm100CanPrimary INTEGER, cpsmm100EthernetLink INTEGER, cpsmm100TntRIP IpAddress, cpsmm100TntRIPMask IpAddress, cpsmm100SNMPTrapMgr IpAddress, cpsmm100SNMPTrapInterval INTEGER, cpsmm100SysUpTime TimeTicks, cpsmm100SysContact DisplayString, cpsmm100SysName DisplayString, cpsmm100SysLocation DisplayString, cpsmm100CfgMatch INTEGER, cpsmm100SerialNumber INTEGER, cpsmm100ICIF INTEGER, cpsmm100MRevision INTEGER, cpsmm100LastGasp INTEGER, cpsmm100SNMPTrapMgr2 IpAddress, cpsmm100SNMPTrapMgr3 IpAddress, cpsmm100SNMPTrapMgr4 IpAddress, cpsmm100CacheClean INTEGER } cpsmm100BiaIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number (BIA) of the cabinet in which the device is installed" ::= { cpsmm100Entry 1 } cpsmm100SlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The slot in which the device is installed" ::= { cpsmm100Entry 2 } cpsmm100Groups OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent can be instructed to apply configuration changes simultaneously to all group members rather than to individual devices. Every Groups string has three automatically defined implied values: 1) The model family of the device, e.g. 'CPSMM100' 2) The serial number of the cabinet in which the device is installed, in decimal with no leading zeroes, e.g. '12345', and 3) same as 2, with the slot in which the device is installed appended, enclosed in square brackets. e.g. '12345[9]'" ::= { cpsmm100Entry 3 } cpsmm100Reset OBJECT-TYPE SYNTAX INTEGER { reset(1), noReset(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Set this to reset(1) to cause the CPSMM100 to reboot." ::= { cpsmm100Entry 4 } cpsmm100SaveConfig OBJECT-TYPE SYNTAX INTEGER { saveConfig(1), noSaveConfig(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Set this to saveConfig(1) to force configuration changes made since the last saveConfig to be copied from RAM to flash memory. If changes are made to the configuration of a CPSMM100 and SaveConfig is not subsequently set to 1, the changes will be made only in RAM and the device will revert to its previous configuration at the next reboot. After the save completes, SaveConfig automatically reverts to noSaveConfig(2)." ::= { cpsmm100Entry 5 } cpsmm100HwRevision OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The hardware revision of this device" ::= { cpsmm100Entry 6 } cpsmm100SwRevision OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The revision of the agent firmware for this device." ::= { cpsmm100Entry 7 } cpsmm100IPAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IP Address of the Ethernet interface of this device" ::= { cpsmm100Entry 8 } cpsmm100SubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The subnet mask used by the Ethernet interface of this device" ::= { cpsmm100Entry 9 } cpsmm100Gateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IP gateway used by the Ethernet interface of this device" ::= { cpsmm100Entry 10 } cpsmm100IsPrimary OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "In a given Point System stack, multiple base management modules can be installed, but only one can be the Primary. The Primary is responsible for scanning the stack for modules, collecting status information and distributing new configuration settings. The Primary management module is therefore the only one that can accept an SNMP SET PDU. Compare this variable with cpsIsPrimary.0" ::= { cpsmm100Entry 11 } cpsmm100WantPrimary OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), always(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Normally, the Management Module installed in the cabinet with the lowest serial number (BIA) in the lowest (leftmost) slot that has fully established network connectivity will be selected as the Primary. Setting WantPrimary to yes(1) causes this device to be preferred over all devices with a WantPrimary value of no(2) during these Primary/Standby negotiations. If more than one device is configured with the value yes(1), these modules negotiate amongst themselves using the default rule above. Setting WantPrimary to always(3) causes the module to ignore the results of the negotiations and immediately and persistently assert primary status. Use of always(3) is not recommended except on advice of Transition Networks technical support, since it may cause your system to behave unpredictably. Setting more than one module in a stack to always(3) will cause erratic behavior." ::= { cpsmm100Entry 12 } cpsmm100CanPrimary OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Value is yes(1) if this device is eligible to become the Primary Management Module. Currently, lack of IP/Ethernet connectivity is the only reason that a module can be ineligible." ::= { cpsmm100Entry 13 } cpsmm100EthernetLink OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Does the management interface of this management module have ethernet link?" ::= { cpsmm100Entry 14 } cpsmm100TntRIP OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "This feature in obsolete as of 08/17/2001. Telnet 'trusted' IP address. Telnet access to the CPSMM100 can be limited to a single station by placing its IP address in TntRIP. Any incoming Telnet request from a station whose IP address does not match TntRIP is ignored. The TntRIP can be modified to accept an entire subnet or other group of IP stations by using TntRIPMask, defined below." ::= { cpsmm100Entry 15 } cpsmm100TntRIPMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "This feature in obsolete as of 08/17/2001. Telnet 'trusted' address mask. See cpsmm100TntRIP. This value can be used to exclude bit positions from consideration when applying TntRIP (above) to a Telnet connection request. For each bit position in TntRIPMask that is a 1, the corresponding bits in the TntRIP and the IP address of the connecting client must be the same. If this is not true, the connection attempt is ignored. Note that the TntRIPMask differs from a true subnet mask (which must have all '1' bits at the left and all '0' bits at the right) in that it may use any bit pattern." ::= { cpsmm100Entry 16 } cpsmm100SNMPTrapMgr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Traps generated by this management module will be sent to this IP address." ::= { cpsmm100Entry 17 } cpsmm100SNMPTrapInterval OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "For future expansion, not currently implemented." ::= { cpsmm100Entry 18 } cpsmm100SysUpTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Mirror of this Management Module's system.sysUpTime.0" ::= { cpsmm100Entry 19 } cpsmm100SysContact OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Mirror of this Management Module's system.sysContact.0" ::= { cpsmm100Entry 20 } cpsmm100SysName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Mirror of this Management Module's system.sysName.0" ::= { cpsmm100Entry 21 } cpsmm100SysLocation OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Mirror of this Management Module's system.sysLocation.0" ::= { cpsmm100Entry 22 } cpsmm100CfgMatch OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notApplicable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) indicates that cpsGroupCtrl.0 is null and therefore no comparison was performed." ::= { cpsmm100Entry 23 } cpsmm100SerialNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number of this device." ::= { cpsmm100Entry 24 } cpsmm100ICIF OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Multiple Management Modules can be installed in a Point System stack. For each cabinet in the stack, exactly one module must be selected to communicate configuration changes to the cabinet hardware and provide a communications pathway to other cabinets. This module is known as the Inter-Cabinet Communications Interface. If there are any Base Management Modules in the cabinet, the one in the lowest slot will be the ICIF. Otherwise, it will be the Expansion Management Module in the lowest slot." ::= { cpsmm100Entry 25 } cpsmm100MRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The marketing revision of this device" ::= { cpsmm100Entry 26 } cpsmm100LastGasp OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Last Gasp support for this device." ::= { cpsmm100Entry 27 } cpsmm100SNMPTrapMgr2 OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Traps generated by this management module will be sent to this IP address." ::= { cpsmm100Entry 28 } cpsmm100SNMPTrapMgr3 OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Traps generated by this management module will be sent to this IP address." ::= { cpsmm100Entry 29 } cpsmm100SNMPTrapMgr4 OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Traps generated by this management module will be sent to this IP address." ::= { cpsmm100Entry 30 } cpsmm100CacheClean OBJECT-TYPE SYNTAX INTEGER { clean(1), dirty(2) } ACCESS read-only STATUS mandatory DESCRIPTION "When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2) Device and Management Module cache are not synchronized. The configuration currently displayed by the application has not been validated by the device. The device may need to correct the configuration, in which case the displayed configuration will change." ::= { cpsmm100Entry 31 } -- ================================================================== -- Table for cpsmm200 expansion management module -- -- NOTE: This device is referred to in marketing literature as CPSMM210 -- cpsmm200Table OBJECT-TYPE SYNTAX SEQUENCE OF Cpsmm200Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Sparse table containing one entry for each CPSMM200-210 and other CPSMM200-xxx Point System Expansion Management Module in the stack, indexed by cabinet serial number and slot." ::= { cpsSlotDetail 2 } cpsmm200Entry OBJECT-TYPE SYNTAX Cpsmm200Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Status entries for a single cpsmm200. (The CPSMM200 has no configuration)" INDEX { cpsmm200BiaIndex, cpsmm200SlotIndex } ::= { cpsmm200Table 1 } Cpsmm200Entry ::= SEQUENCE { cpsmm200BiaIndex INTEGER, cpsmm200SlotIndex INTEGER, cpsmm200SerialNumber INTEGER, cpsmm200ICIF INTEGER, cpsmm200MRevision INTEGER } cpsmm200BiaIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number (BIA) of the cabinet in which the device is installed" ::= { cpsmm200Entry 1 } cpsmm200SlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The slot in which the device is installed" ::= { cpsmm200Entry 2 } cpsmm200SerialNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number of this device" ::= { cpsmm200Entry 3 } cpsmm200ICIF OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Multiple Management Modules can be installed in a Point System stack. For each cabinet in the stack, exactly one module must be selected to communicate configuration changes to the cabinet hardware and provide a communications pathway to other cabinets. This module is known as the Inter-Cabinet Communications Interface. If there are any Base Management Modules in the cabinet, the one in the lowest slot will be the ICIF. Otherwise, it will be the Expansion Management Module in the lowest slot." ::= { cpsmm200Entry 4 } cpsmm200MRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The marketing revision of this device" ::= { cpsmm200Entry 5 } -- =================================================================== -- Table for a CETTF100 media converter cettf100Table OBJECT-TYPE SYNTAX SEQUENCE OF Cettf100Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Sparse table containing one entry for each CETTF100 10Mbps Twisted-Pair to Fiber Ethernet Media Converter in the stack, indexed by cabinet serial number and slot." ::= { cpsSlotDetail 3 } cettf100Entry OBJECT-TYPE SYNTAX Cettf100Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Status and configuration entries for a single CETTF100" INDEX { cettf100BiaIndex, cettf100SlotIndex } ::= { cettf100Table 1 } Cettf100Entry ::= SEQUENCE { cettf100BiaIndex INTEGER, cettf100SlotIndex INTEGER, cettf100Groups DisplayString, cettf100MRevision INTEGER, cettf100CfgMatch INTEGER, cettf100SerialNumber INTEGER, cettf100ConnA INTEGER, cettf100ConnB INTEGER, cettf100TPLink INTEGER, cettf100FiberLink INTEGER, cettf100Fault INTEGER, cettf100TPActivity INTEGER, cettf100FiberActivity INTEGER, cettf100AutoCross INTEGER, cettf100LinkPassThrough INTEGER, cettf100ConfigMode INTEGER, cettf100Enabled INTEGER, cettf100CacheClean INTEGER } cettf100BiaIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number (BIA) of the cabinet in which the device is installed" ::= { cettf100Entry 1 } cettf100SlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The slot in which the device is installed" ::= { cettf100Entry 2 } cettf100Groups OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent can be instructed to apply configuration changes simultaneously to all group members rather than to individual devices. Every Groups string has three automatically defined implied values: 1) The model family of the device, e.g. 'CETTF100' 2) The serial number of the cabinet in which the device is installed, in decimal with no leading zeroes, e.g. '12345', and 3) same as 2, with the slot in which the device is installed appended, enclosed in square brackets. e.g. '12345[9]'" ::= { cettf100Entry 3 } cettf100MRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The marketing revision of this device" ::= { cettf100Entry 4 } cettf100CfgMatch OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notApplicable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) indicates that cpsGroupCtrl.0 is null and therefore no comparison was performed." ::= { cettf100Entry 5 } cettf100SerialNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number of this device" ::= { cettf100Entry 6 } cettf100ConnA OBJECT-TYPE SYNTAX CpsConnector ACCESS read-only STATUS mandatory DESCRIPTION "The style of Fiber connector built into this device" ::= { cettf100Entry 7 } cettf100ConnB OBJECT-TYPE SYNTAX CpsConnector ACCESS read-only STATUS mandatory DESCRIPTION "The style of Copper connector built into this device" ::= { cettf100Entry 8 } cettf100TPLink OBJECT-TYPE SYNTAX INTEGER { linkUp(1), linkDown(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of Copper Link for this device" ::= { cettf100Entry 9 } cettf100FiberLink OBJECT-TYPE SYNTAX INTEGER { linkUp(1), linkDown(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of Fiber Link for this device" ::= { cettf100Entry 10 } cettf100Fault OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Value is yes(1) when either TPLink or FiberLink has value linkDown(2)" ::= { cettf100Entry 11 } cettf100TPActivity OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Network traffic indicator for Copper side of this device" ::= { cettf100Entry 12 } cettf100FiberActivity OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Network traffic indicator for Fiber side of this device" ::= { cettf100Entry 13 } cettf100AutoCross OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/Disable for automatic copper TX/RX pair correction" ::= { cettf100Entry 14 } cettf100LinkPassThrough OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/Disable for Link Pass Through, a feature that causes loss of link on one side of a media converter to be passed through to the other side, so that upstream equipment can see the fault condition." ::= { cettf100Entry 15 } cettf100ConfigMode OBJECT-TYPE SYNTAX INTEGER { software(1), hardware(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all configuration control comes from physical switches or jumpers on the device." ::= { cettf100Entry 16 } cettf100Enabled OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When this configuration item is set to no(2), the device passes no network traffic." ::= { cettf100Entry 17 } cettf100CacheClean OBJECT-TYPE SYNTAX INTEGER { clean(1), dirty(2) } ACCESS read-only STATUS mandatory DESCRIPTION "When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2) Device and Management Module cache are not synchronized. The configuration currently displayed by the application has not been validated by the device. The device may need to correct the configuration, in which case the displayed configuration will change." ::= { cettf100Entry 18 } -- ================================================================== -- Table for a cfetf100 slide in card. cfetf100Table OBJECT-TYPE SYNTAX SEQUENCE OF Cfetf100Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Sparse table containing one entry for each CFTEF100 100Mbps Twisted-Pair to Fiber Ethernet Media Converter in the stack, indexed by cabinet serial number and slot." ::= { cpsSlotDetail 4 } cfetf100Entry OBJECT-TYPE SYNTAX Cfetf100Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Status and configuration entries for a single CFETF100" INDEX { cfetf100BiaIndex, cfetf100SlotIndex } ::= { cfetf100Table 1 } Cfetf100Entry ::= SEQUENCE { cfetf100BiaIndex INTEGER, cfetf100SlotIndex INTEGER, cfetf100Groups DisplayString, cfetf100MRevision INTEGER, cfetf100CfgMatch INTEGER, cfetf100SerialNumber INTEGER, cfetf100ConnA INTEGER, cfetf100ConnB INTEGER, cfetf100TPLink INTEGER, cfetf100FiberLink INTEGER, cfetf100Fault INTEGER, cfetf100FastLinkPulse INTEGER, cfetf100Enabled INTEGER, cfetf100Pause INTEGER, cfetf100LinkPassThrough INTEGER, cfetf100AutoCross INTEGER, cfetf100TPActivity INTEGER, cfetf100FiberActivity INTEGER, cfetf100ConfigMode INTEGER, cfetf100FarEndFault INTEGER, cfetf100CacheClean INTEGER } cfetf100BiaIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number (BIA) of the cabinet in which the device is installed" ::= { cfetf100Entry 1 } cfetf100SlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The slot in which the device is installed" ::= { cfetf100Entry 2 } cfetf100Groups OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent can be instructed to apply configuration changes simultaneously to all group members rather than to individual devices. Every Groups string has three automatically defined implied values: 1) The model family of the device, e.g. 'CFETF100' 2) The serial number of the cabinet in which the device is installed, in decimal with no leading zeroes, e.g. '12345', and 3) same as 2, with the slot in which the device is installed appended, enclosed in square brackets. e.g. '12345[9]'" ::= { cfetf100Entry 3 } cfetf100MRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The marketing revision of this device" ::= { cfetf100Entry 4 } cfetf100CfgMatch OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notApplicable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) indicates that cpsGroupCtrl.0 is null and therefore no comparison was performed." ::= { cfetf100Entry 5 } cfetf100SerialNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number of this device" ::= { cfetf100Entry 6 } cfetf100ConnA OBJECT-TYPE SYNTAX CpsConnector ACCESS read-only STATUS mandatory DESCRIPTION "The style of Fiber connector built into this device" ::= { cfetf100Entry 7 } cfetf100ConnB OBJECT-TYPE SYNTAX CpsConnector ACCESS read-only STATUS mandatory DESCRIPTION "The style of Copper connector built into this device" ::= { cfetf100Entry 8 } cfetf100TPLink OBJECT-TYPE SYNTAX INTEGER { linkUp(1), linkDown(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of Twisted Pair Link for this device" ::= { cfetf100Entry 9 } cfetf100FiberLink OBJECT-TYPE SYNTAX INTEGER { linkUp(1), linkDown(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of Fiber Link for this device" ::= { cfetf100Entry 10 } cfetf100Fault OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Value is yes(1) when either TPLink or FiberLink has value linkDown(2)" ::= { cfetf100Entry 11 } cfetf100FastLinkPulse OBJECT-TYPE SYNTAX INTEGER { autonegotiate(1), hdx100Btx(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When set to autonegotiate(1), converter sends Fast Link Pulses on its twisted pair port, thereby participating in autonegotiation of duplex between the converter's twisted pair port and that of the connected station. If that station supports Full- Duplex (FDX) operation, FDX will be used. If not, the twisted pair will operate in Half-Duplex (HDX) mode. When set to hdx100Btx(2), the converter instead sends 100Mbps idles (rather than Fast Link Pulses) on its twisted pair port (i.e. it declines to negotiate), which forces the twisted pair to operate in HDX mode regardless of the capabilities of the connected station. When operating in HDX mode, the twisted pair can support traffic in only one direction at a time. In FDX mode, traffic can pass in both directions simultaneously, thus theoretically doubling network performance." ::= { cfetf100Entry 12 } cfetf100Enabled OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When this configuration item is set to no(2), the device passes no network traffic." ::= { cfetf100Entry 13 } cfetf100Pause OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The Pause feature allows Ethernet MACs that support it to send data pacing 'Pause' messages to each other. Support for Pause is negotiated at the physical level and passed up to the MAC. While the MAC's Pause messages themselves can pass over the fiber link that this pair of media converters introduces, the TP physical layer negotiations to enable Pause can not. Therefore, if both end station MACs support Pause and wish to use it, the Pause negotiation must be re-generated by the media converters on both ends. By setting this configuration option to enabled(1), you are indicating to the local twisted pair station that the twisted pair station on the other side of the other media converter supports Pause and wishes to use it. This variable must be set consistently on both of the paired media converters." ::= { cfetf100Entry 14 } cfetf100LinkPassThrough OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/Disable for Link Pass Through, a feature that causes loss of link on one side of a media converter to be passed through to the other side, so that upstream equipment can see the fault condition." ::= { cfetf100Entry 15 } cfetf100AutoCross OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/Disable for automatic copper TX/RX pair correction. When disabled, the port operates in MDI mode." ::= { cfetf100Entry 16 } cfetf100TPActivity OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notSupported(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Network traffic indicator for Copper side of this device" ::= { cfetf100Entry 17 } cfetf100FiberActivity OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notSupported(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Network traffic indicator for Fiber side of this device" ::= { cfetf100Entry 18 } cfetf100ConfigMode OBJECT-TYPE SYNTAX INTEGER { software(1), hardware(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all configuration control comes from physical switches or jumpers on the device." ::= { cfetf100Entry 19 } cfetf100FarEndFault OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notSupported(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Far End Fault configuration of this device. This setting can only be changed by the physical jumper setting on the slide in card, for some devices, if it is available. Far End Fault is software read-write on other devices. Far End Fault causes the fiber transmitter to generate a Far End Fault pattern upon the loss of a receiver signal detect. When the receiver detects signal again, the transmitter stops transmitting the Far End Fault pattern." ::= { cfetf100Entry 20 } cfetf100CacheClean OBJECT-TYPE SYNTAX INTEGER { clean(1), dirty(2) } ACCESS read-only STATUS mandatory DESCRIPTION "When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2) Device and Management Module cache are not synchronized. The configuration currently displayed by the application has not been validated by the device. The device may need to correct the configuration, in which case the displayed configuration will change." ::= { cfetf100Entry 21 } -- ================================================================== -- Table for a cfmff100 slide in device cfmff100Table OBJECT-TYPE SYNTAX SEQUENCE OF Cfmff100Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Sparse table containing one entry for each CFMFF100 SingleMode to MultiMode Fiber Media Converter in the stack, indexed by cabinet serial number and slot." ::= { cpsSlotDetail 5 } cfmff100Entry OBJECT-TYPE SYNTAX Cfmff100Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Status and configuration entries for a single CFMFF100" INDEX { cfmff100BiaIndex, cfmff100SlotIndex } ::= { cfmff100Table 1 } Cfmff100Entry ::= SEQUENCE { cfmff100BiaIndex INTEGER, cfmff100SlotIndex INTEGER, cfmff100Groups DisplayString, cfmff100MRevision INTEGER, cfmff100CfgMatch INTEGER, cfmff100ConnA INTEGER, cfmff100ConnB INTEGER, cfmff100SerialNumber INTEGER, cfmff100SMSignal INTEGER, cfmff100MMSignal INTEGER, cfmff100Enabled INTEGER, cfmff100PortShutOff INTEGER, cfmff100ConfigMode INTEGER, cfmff100CacheClean INTEGER } cfmff100BiaIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number (BIA) of the cabinet in which the device is installed" ::= { cfmff100Entry 1 } cfmff100SlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The slot in which the device is installed" ::= { cfmff100Entry 2 } cfmff100Groups OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent can be instructed to apply configuration changes simultaneously to all group members rather than to individual devices. Every Groups string has three automatically defined implied values: 1) The model family of the device, e.g. 'CFMFF100' 2) The serial number of the cabinet in which the device is installed, in decimal with no leading zeroes, e.g. '12345', and 3) same as 2, with the slot in which the device is installed appended, enclosed in square brackets. e.g. '12345[9]'" ::= { cfmff100Entry 3 } cfmff100MRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The marketing revision of the device" ::= { cfmff100Entry 4 } cfmff100CfgMatch OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notApplicable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) indicates that cpsGroupCtrl.0 is null and therefore no comparison was performed." ::= { cfmff100Entry 5 } cfmff100ConnA OBJECT-TYPE SYNTAX CpsConnector ACCESS read-only STATUS mandatory DESCRIPTION "The style of SingleMode connector built into this device" ::= { cfmff100Entry 6 } cfmff100ConnB OBJECT-TYPE SYNTAX CpsConnector ACCESS read-only STATUS mandatory DESCRIPTION "The style of MultiMode connector built into this device" ::= { cfmff100Entry 7 } cfmff100SerialNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number of this device" ::= { cfmff100Entry 8 } cfmff100SMSignal OBJECT-TYPE SYNTAX INTEGER { signalUp(1), signalDown(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of singlemode signal detect for this device" ::= { cfmff100Entry 9 } cfmff100MMSignal OBJECT-TYPE SYNTAX INTEGER { signalUp(1), signalDown(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of singlemode signal detect for this device" ::= { cfmff100Entry 10 } cfmff100Enabled OBJECT-TYPE SYNTAX INTEGER { yes(1), noP1(2), noP2(3), no(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Ports on this device can be disabled individually. When this control is set to yes(1), the entire device is enabled. When it is set to noP1(2), the SingleMode port is disabled. noP2(3) disables the MultiMode port only, and no(4) disables both. For most purposes, the values noP1(2), noP2(3), and no(4) are equivalent." ::= { cfmff100Entry 11 } cfmff100PortShutOff OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This variable reflects the status of the DPT/OPP jumper on the board. This jumper controls the behavior of the converter when a loss of signal is detected. When the jumper is in the default OPP position, the loss of signal detect on one port causes the opposite port to be shut down. In this case, Port Shutoff is said to be disabled(2). In the DPT (enabled(1)) position, both ports are shut down. Use of the DPT position is discouraged, as it is more likely to lead to a signal loss condition from which the converter is unable to recover." ::= { cfmff100Entry 12 } cfmff100ConfigMode OBJECT-TYPE SYNTAX INTEGER { software(1), hardware(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all configuration control comes from physical switches or jumpers on the device." ::= { cfmff100Entry 13 } cfmff100CacheClean OBJECT-TYPE SYNTAX INTEGER { clean(1), dirty(2) } ACCESS read-only STATUS mandatory DESCRIPTION "When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2) Device and Management Module cache are not synchronized. The configuration currently displayed by the application has not been validated by the device. The device may need to correct the configuration, in which case the displayed configuration will change." ::= { cfmff100Entry 14 } -- ================================================================ -- Table for the cpsmp100 cpsmp100Table OBJECT-TYPE SYNTAX SEQUENCE OF Cpsmp100Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Sparse table containing one entry for each CPSMP100 IFO (Instant Fail-Over) Power Supply in the stack, indexed by cabinet serial number and slot." ::= { cpsSlotDetail 6 } cpsmp100Entry OBJECT-TYPE SYNTAX Cpsmp100Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Status and configuration entries for a single CPSMP100" INDEX { cpsmp100BiaIndex, cpsmp100SlotIndex } ::= { cpsmp100Table 1 } Cpsmp100Entry ::= SEQUENCE { cpsmp100BiaIndex INTEGER, cpsmp100SlotIndex INTEGER, cpsmp100Groups DisplayString, cpsmp100MRevision INTEGER, cpsmp100CfgMatch INTEGER, cpsmp100SerialNumber INTEGER, cpsmp100Mode INTEGER, cpsmp100ConfigMode INTEGER, cpsmp100RemoteFan INTEGER, cpsmp100PowerOK INTEGER, cpsmp100InUse INTEGER, cpsmp100ChassisPower INTEGER, cpsmp100ChassisTemp INTEGER, cpsmp100RFanFault INTEGER, cpsmp100LFanFault INTEGER, cpsmp100SupplyType INTEGER, cpsmp100CacheClean INTEGER } cpsmp100BiaIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number (BIA) of the cabinet in which the device is installed" ::= { cpsmp100Entry 1 } cpsmp100SlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The slot in which the device is installed. Power Supplies occupy special slots numbered 125 and higher." ::= { cpsmp100Entry 2 } cpsmp100Groups OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent can be instructed to apply configuration changes simultaneously to all group members rather than to individual devices. Every Groups string has three automatically defined implied values: 1) The model family of the device, e.g. 'CPSMP100' 2) The serial number of the cabinet in which the device is installed, in decimal with no leading zeroes, e.g. '12345', and 3) same as 2, with the slot in which the device is installed appended, enclosed in square brackets. e.g. '12345[9]'" ::= { cpsmp100Entry 3 } cpsmp100MRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The marketing revision of this device" ::= { cpsmp100Entry 4 } cpsmp100CfgMatch OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notApplicable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) indicates that cpsGroupCtrl.0 is null and therefore no comparison was performed." ::= { cpsmp100Entry 5 } cpsmp100SerialNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number of this device" ::= { cpsmp100Entry 6 } cpsmp100Mode OBJECT-TYPE SYNTAX INTEGER { master(1), slave(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When one power supply is set to master(1) and the other is set to slave(2), the master will supply all power to the cabinet, and the slave will take over if the master stops supplying power. This is useful when (for example) one supply is attached to a wall socket and the other to a battery backup. The cabinet can be directed to only draw power from batteries when there is no alternative. When both power supplies are set to master(1), the results are determined automatically. WARNING: It is up to the system administrator to ensure that at least one power supply is set to master(1). It is illegal to set all power supplies to slave(2). If this occurs, the cabinet may lose all power under certain circumstances, even if power is available." ::= { cpsmp100Entry 7 } cpsmp100ConfigMode OBJECT-TYPE SYNTAX INTEGER { software(1), hardware(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all configuration control comes from physical switches or jumpers on the device." ::= { cpsmp100Entry 8 } cpsmp100RemoteFan OBJECT-TYPE SYNTAX INTEGER { installed(1), notInstalled(2) } ACCESS read-only STATUS mandatory DESCRIPTION "A Remote Fan is a device that fits in a power supply slot but contains no power supply, only a fan. These devices are not manageable, but if present they will be reported by the manageable supply that accompanies it." ::= { cpsmp100Entry 9 } cpsmp100PowerOK OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This variable has the value yes(1) any time this supply is capable of supplying at least 11.6 volts to the cabinet. Note that a value of no(2) does not necessarily indicate hard failure. A power supply can be detected even if it is powered down or not plugged in as long as another power supply has PowerOK=yes(1) and InUse=yes(1). In this case, PowerOK will be no(2) for the disabled power supply." ::= { cpsmp100Entry 10 } cpsmp100InUse OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Value is yes(1) when this supply is currently selected to supply power to the cabinet." ::= { cpsmp100Entry 11 } cpsmp100ChassisPower OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Power currently supplied to the cabinet, in milliwatts" ::= { cpsmp100Entry 12 } cpsmp100ChassisTemp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The temperature inside the cabinet as detected by the power supply, in tenths of degrees centigrade" ::= { cpsmp100Entry 13 } cpsmp100RFanFault OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Normally no(2), this value changes to yes(1) when an installed Remote fan is drawing excessive current or none at all." ::= { cpsmp100Entry 14 } cpsmp100LFanFault OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Normally no(2), this value changes to yes(1) when the Local fan is drawing excessive current or none at all." ::= { cpsmp100Entry 15 } cpsmp100SupplyType OBJECT-TYPE SYNTAX INTEGER { ac(1), dc48(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The supply voltage that this unit is designed to accept. If AC(1), the supply accepts 90-260VAC, 47 to 400Hz. If DC48(2), the supply accepts 38-75VDC." ::= { cpsmp100Entry 16 } cpsmp100CacheClean OBJECT-TYPE SYNTAX INTEGER { clean(1), dirty(2) } ACCESS read-only STATUS mandatory DESCRIPTION "When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2) Device and Management Module cache are not synchronized. The configuration currently displayed by the application has not been validated by the device. The device may need to correct the configuration, in which case the displayed configuration will change." ::= { cpsmp100Entry 17 } -- ================================================================ -- Table for the csetf100 csetf100Table OBJECT-TYPE SYNTAX SEQUENCE OF Csetf100Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Sparse table containing one entry for each CSETF100 10/100Mbps Twisted-Pair to Fiber Ethernet Media Converter in the stack, indexed by cabinet serial number and slot." ::= { cpsSlotDetail 7 } csetf100Entry OBJECT-TYPE SYNTAX Csetf100Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "One table entry per piece of management module information. Entry 'n' does not exist." INDEX { csetf100BiaIndex, csetf100SlotIndex } ::= { csetf100Table 1 } Csetf100Entry ::= SEQUENCE { csetf100BiaIndex INTEGER, csetf100SlotIndex INTEGER, csetf100Groups DisplayString, csetf100MRevision INTEGER, csetf100CfgMatch INTEGER, csetf100SerialNumber INTEGER, csetf100ConnA INTEGER, csetf100ConnB INTEGER, csetf100TPLink INTEGER, csetf100FiberLink INTEGER, csetf100AutoCross INTEGER, csetf100SpeedConfig INTEGER, csetf100Speed100Mbps INTEGER, csetf100TPActivity INTEGER, csetf100FiberActivity INTEGER, csetf100ConfigMode INTEGER, csetf100CacheClean INTEGER } csetf100BiaIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number (BIA) of the cabinet in which the device is installed" ::= { csetf100Entry 1 } csetf100SlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The slot in which the device is installed" ::= { csetf100Entry 2 } csetf100Groups OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent can be instructed to apply configuration changes simultaneously to all group members rather than to individual devices. Every Groups string has three automatically defined implied values: 1) The model family of the device, e.g. 'CSETF100' 2) The serial number of the cabinet in which the device is installed, in decimal with no leading zeroes, e.g. '12345', and 3) same as 2, with the slot in which the device is installed appended, enclosed in square brackets. e.g. '12345[9]'" ::= { csetf100Entry 3 } csetf100MRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The marketing revision of this device" ::= { csetf100Entry 4 } csetf100CfgMatch OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), inactive(3) } ACCESS read-only STATUS mandatory DESCRIPTION "yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) indicates that cpsGroupCtrl.0 is null and therefore no comparison was performed." ::= { csetf100Entry 5 } csetf100SerialNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number of this device" ::= { csetf100Entry 6 } csetf100ConnA OBJECT-TYPE SYNTAX CpsConnector ACCESS read-only STATUS mandatory DESCRIPTION "The style of Fiber connector built into this device" ::= { csetf100Entry 7 } csetf100ConnB OBJECT-TYPE SYNTAX CpsConnector ACCESS read-only STATUS mandatory DESCRIPTION "The style of Copper connector built into this device" ::= { csetf100Entry 8 } csetf100TPLink OBJECT-TYPE SYNTAX INTEGER { linkUp(1), linkDown(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of Twisted Pair Link for this device" ::= { csetf100Entry 9 } csetf100FiberLink OBJECT-TYPE SYNTAX INTEGER { linkUp(1), linkDown(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of Fiber Link for this device" ::= { csetf100Entry 10 } csetf100AutoCross OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/Disable for automatic copper TX/RX pair correction" ::= { csetf100Entry 11 } csetf100SpeedConfig OBJECT-TYPE SYNTAX INTEGER { auto(1), mbps10(2), mbps100(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows the user to set the requested data transfer rate for this converter." ::= { csetf100Entry 12 } csetf100Speed100Mbps OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This variable reports the current data transfer rate for this converter." ::= { csetf100Entry 13 } csetf100TPActivity OBJECT-TYPE SYNTAX INTEGER { activity(1), noActivity(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Network traffic indicator for Copper side of this device" ::= { csetf100Entry 14 } csetf100FiberActivity OBJECT-TYPE SYNTAX INTEGER { activity(1), noActivity(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Network traffic indicator for Fiber side of this device" ::= { csetf100Entry 15 } csetf100ConfigMode OBJECT-TYPE SYNTAX INTEGER { software(1), hardware(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all configuration control comes from physical switches or jumpers on the device." ::= { csetf100Entry 16 } csetf100CacheClean OBJECT-TYPE SYNTAX INTEGER { clean(1), dirty(2) } ACCESS read-only STATUS mandatory DESCRIPTION "When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2) Device and Management Module cache are not synchronized. The configuration currently displayed by the application has not been validated by the device. The device may need to correct the configuration, in which case the displayed configuration will change." ::= { csetf100Entry 17 } -- ================================================================ -- Table for the cgetf100 cgetf100Table OBJECT-TYPE SYNTAX SEQUENCE OF Cgetf100Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Sparse table containing one entry for each CGETF100 Gigabit Twisted-Pair to Fiber Ethernet Media Converter in the stack, indexed by cabinet serial number and slot." ::= { cpsSlotDetail 8 } cgetf100Entry OBJECT-TYPE SYNTAX Cgetf100Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "One table entry per piece of management module information. Entry 'n' does not exist." INDEX { cgetf100BiaIndex, cgetf100SlotIndex } ::= { cgetf100Table 1 } Cgetf100Entry ::= SEQUENCE { cgetf100BiaIndex INTEGER, cgetf100SlotIndex INTEGER, cgetf100Groups DisplayString, cgetf100MRevision INTEGER, cgetf100CfgMatch INTEGER, cgetf100SerialNumber INTEGER, cgetf100ConnA INTEGER, cgetf100ConnB INTEGER, cgetf100TPLink INTEGER, cgetf100FiberLink INTEGER, cgetf100Fault INTEGER, cgetf100Enabled INTEGER, cgetf100Pause INTEGER, cgetf100LinkPassThrough INTEGER, cgetf100FullDuplex INTEGER, cgetf100ClockMaster INTEGER, cgetf100ConfigMode INTEGER, cgetf100TPLength INTEGER, cgetf100FiberAutoNegot INTEGER, cgetf100CacheClean INTEGER, cgetf100PauseType INTEGER } cgetf100BiaIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number (BIA) of the cabinet in which the device is installed" ::= { cgetf100Entry 1 } cgetf100SlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The slot in which the device is installed" ::= { cgetf100Entry 2 } cgetf100Groups OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent can be instructed to apply configuration changes simultaneously to all group members rather than to individual devices. Every Groups string has three automatically defined implied values: 1) The model family of the device, e.g. 'CGETF100' 2) The serial number of the cabinet in which the device is installed, in decimal with no leading zeroes, e.g. '12345', and 3) same as 2, with the slot in which the device is installed appended, enclosed in square brackets. e.g. '12345[9]'" ::= { cgetf100Entry 3 } cgetf100MRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The marketing revision of this device" ::= { cgetf100Entry 4 } cgetf100CfgMatch OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), inactive(3) } ACCESS read-only STATUS mandatory DESCRIPTION "yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) indicates that cpsGroupCtrl.0 is null and therefore no comparison was performed." ::= { cgetf100Entry 5 } cgetf100SerialNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number of this device" ::= { cgetf100Entry 6 } cgetf100ConnA OBJECT-TYPE SYNTAX CpsConnector ACCESS read-only STATUS mandatory DESCRIPTION "The style of Fiber connector built into this device" ::= { cgetf100Entry 7 } cgetf100ConnB OBJECT-TYPE SYNTAX CpsConnector ACCESS read-only STATUS mandatory DESCRIPTION "The style of Copper connector built into this device" ::= { cgetf100Entry 8 } cgetf100TPLink OBJECT-TYPE SYNTAX INTEGER { linkUp(1), linkDown(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of Twisted Pair Link for this device" ::= { cgetf100Entry 9 } cgetf100FiberLink OBJECT-TYPE SYNTAX INTEGER { linkUp(1), linkDown(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of Fiber Link for this device" ::= { cgetf100Entry 10 } cgetf100Fault OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Value is yes(1) when either TPLink or FiberLink has value linkDown(2)" ::= { cgetf100Entry 11 } cgetf100Enabled OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When this variable is set to no(1), the device allows no traffic to pass." ::= { cgetf100Entry 12 } cgetf100Pause OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/Disable control for the advertising of Pause capability on the copper interface. This MIB variable is retained for compatibility with older applications and firmware. If you have a current version of the CGETF100 device (which supports asymmetric pause), you should both read and write the MIB variable cgetf100PauseType(21) for complete monitoring and control of pause capability advertising. If you are using a current Transition Networks application, this is automatic. On all versions of the CGETF100 device, this MIB variable can be used to enable and disable advertising of symmetric pause. For current versions of the CGETF100, this variable reads enabled(1) any time any type of pause is enabled, and forces cgetf100PauseType(21) to symmetric(1) when changed from disabled(2) to enabled(1). On new versions of the CGETF100 device, when cgetf100FiberAutoNegot(19) has the value enabled(1), this variable takes on the read-only value enabled(1)." ::= { cgetf100Entry 13 } cgetf100LinkPassThrough OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/Disable for Link Pass Through, a feature that causes loss of link on one side of a media converter to be passed through to the other side, so that upstream equipment can see the fault condition." ::= { cgetf100Entry 14 } cgetf100FullDuplex OBJECT-TYPE SYNTAX INTEGER { fullDuplex(1), halfDuplex(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Controls advertizing of duplex capability for the copper side of the converter. When set to fullDuplex(1), the converter advertizes full duplex capability. When set to halfDuplex(2), the converter advertizes half duplex capability. The converter never advertizes both simultaneously. If the advertized setting is not supported by the remote, link cannot be established." ::= { cgetf100Entry 15 } cgetf100ClockMaster OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "When yes(1), the converter is supplying clock to the twisted pair. When no(2), the remote supplies the clock." ::= { cgetf100Entry 16 } cgetf100ConfigMode OBJECT-TYPE SYNTAX INTEGER { software(1), hardware(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all configuration control comes from physical switches or jumpers on the device." ::= { cgetf100Entry 17 } cgetf100TPLength OBJECT-TYPE SYNTAX INTEGER { ln-lt50(1), ln-50-80(2), ln-80-110(3), ln-110-140(4), ln-gt140(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Twisted-pair length estimated via the converter's internal Time Domain Reflectometer. 1 means less than 50 meters, 2 means 50 to 80 meters, 3 means 80 to 110 meters, 4 means 110 to 140 meters, and 5 means more than 140 meters." ::= { cgetf100Entry 18 } cgetf100FiberAutoNegot OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notApplicable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Fiber port autonegotiation configuration." ::= { cgetf100Entry 19 } cgetf100CacheClean OBJECT-TYPE SYNTAX INTEGER { clean(1), dirty(2) } ACCESS read-only STATUS mandatory DESCRIPTION "When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2) Device and Management Module cache are not synchronized. The configuration currently displayed by the application has not been validated by the device. The device may need to correct the configuration, in which case the displayed configuration will change." ::= { cgetf100Entry 20 } cgetf100PauseType OBJECT-TYPE SYNTAX INTEGER { symmetric(1), asymRX(2), asymTX(3), disabled(4), notApplicable(5), symmetricRO(6), asymRXRO(7), asymTXRO(8), disabledRO(9), all(10) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/Disable control for the advertising of Pause capability on the copper interface. This MIB variable is only functional on CGETF100 devices that support asymmetric pause (i.e. current versions). If your CGETF100 does not support asymmetric pause, this variable will return the read-only value notApplicable(5) regardless of any other factors. On current CGETF100 devices, selectable values for this variable are symmetric(1), asymRX(2) (asymmetric, pause frames flow towards the converter), asymTX(3) (asymmetric, pause frames flow towards the link partner), and disabled(4). Note: Changing cgetf100PauseType(21) to disabled(4) causes cgetf100Pause(13) to take on the value disabled(2). Changing cgetf100PauseType(21) to any selectable value other than disabled(4) causes cgetf100Pause(13) to take on the value enabled(1). If cgetf100FiberAutoNegot(19) has the value enabled(1), then this variable returns the read-only value all(10), which indicates that all advertised modes received from the twisted pair link partner are reflected back to the link partner. Otherwise, if cgetf100ConfigMode(17) has the value hardware(2), one of the following read-only values will be returned: symmetricRO(6) or disabledRO(9). The read-only values asymRXRO(7) and asymTXRO(8) are defined for future expansion." ::= { cgetf100Entry 21 } --===================================================================== -- Table for the csdtf100 csdtf100Table OBJECT-TYPE SYNTAX SEQUENCE OF Csdtf100Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Sparse table containing one entry for each CSDTF100 T1/E1 Copper to Fiber Media Converter in the stack, indexed by cabinet serial number and slot." ::= { cpsSlotDetail 9 } csdtf100Entry OBJECT-TYPE SYNTAX Csdtf100Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Status and configuration entries for a single CSDTF100" INDEX { csdtf100BiaIndex, csdtf100SlotIndex } ::= { csdtf100Table 1 } Csdtf100Entry ::= SEQUENCE { csdtf100BiaIndex INTEGER, csdtf100SlotIndex INTEGER, csdtf100Groups DisplayString, csdtf100MRevision INTEGER, csdtf100CfgMatch INTEGER, csdtf100SerialNumber INTEGER, csdtf100ConnA INTEGER, csdtf100ConnB INTEGER, csdtf100CopperLink INTEGER, csdtf100FiberLink INTEGER, csdtf100Fault INTEGER, csdtf100TAOSFiber INTEGER, csdtf100TAOSCopper INTEGER, csdtf100AISFiber INTEGER, csdtf100AISCopper INTEGER, csdtf100CopperLoopback INTEGER, csdtf100CopperLongHaul INTEGER, csdtf100T1E1 INTEGER, csdtf100ConfigMode INTEGER, csdtf100TPCoax INTEGER, csdtf100CopperLineBuildout INTEGER, csdtf100FiberLoopback INTEGER, csdtf100RmtSupported INTEGER, csdtf100RmtDetected INTEGER, csdtf100RmtMRevision INTEGER, csdtf100RmtSerialNumber INTEGER, csdtf100RmtConnA INTEGER, csdtf100RmtConnB INTEGER, csdtf100RmtCopperLink INTEGER, csdtf100RmtFiberLink INTEGER, csdtf100RmtFault INTEGER, csdtf100RmtTAOSFiber INTEGER, csdtf100RmtTAOSCopper INTEGER, csdtf100RmtAISFiber INTEGER, csdtf100RmtAISCopper INTEGER, csdtf100RmtCopperLoopback INTEGER, csdtf100RmtCopperLongHaul INTEGER, csdtf100RmtConfigMode INTEGER, csdtf100RmtTPCoax INTEGER, csdtf100RmtCopperLineBuildout INTEGER, csdtf100RmtFiberLoopback INTEGER, csdtf100CacheClean INTEGER } csdtf100BiaIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number (BIA) of the cabinet in which the device is installed" ::= { csdtf100Entry 1 } csdtf100SlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The slot in which the device is installed" ::= { csdtf100Entry 2 } csdtf100Groups OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent can be instructed to apply configuration changes simultaneously to all group members rather than to individual devices. Every Groups string has three automatically defined implied values: 1) The model family of the device, e.g. 'CSDTF100' 2) The serial number of the cabinet in which the device is installed, in decimal with no leading zeroes, e.g. '12345', and 3) same as 2, with the slot in which the device is installed appended, enclosed in square brackets. e.g. '12345[9]'" ::= { csdtf100Entry 3 } csdtf100MRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The marketing revision of this device" ::= { csdtf100Entry 4 } csdtf100CfgMatch OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), inactive(3) } ACCESS read-only STATUS mandatory DESCRIPTION "yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) indicates that cpsGroupCtrl.0 is null and therefore no comparison was performed." ::= { csdtf100Entry 5 } csdtf100SerialNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number of this device" ::= { csdtf100Entry 6 } csdtf100ConnA OBJECT-TYPE SYNTAX CpsConnector ACCESS read-only STATUS mandatory DESCRIPTION "The style of Fiber connector built into this device" ::= { csdtf100Entry 7 } csdtf100ConnB OBJECT-TYPE SYNTAX CpsConnector ACCESS read-only STATUS mandatory DESCRIPTION "The style of Copper connector built into this device" ::= { csdtf100Entry 8 } csdtf100CopperLink OBJECT-TYPE SYNTAX INTEGER { linkUp(1), linkDown(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of Copper Link for this device" ::= { csdtf100Entry 9 } csdtf100FiberLink OBJECT-TYPE SYNTAX INTEGER { linkUp(1), linkDown(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of Fiber Link for this device" ::= { csdtf100Entry 10 } csdtf100Fault OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Value is yes(1) when either CopperLink or FiberLink has value linkDown(2)" ::= { csdtf100Entry 11 } csdtf100TAOSFiber OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Transmit All Ones on Fiber as an error signal when Copper interface is down. When this error signal is transmitted, the AIS of the device on the other end is activated, if supported." ::= { csdtf100Entry 12 } csdtf100TAOSCopper OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Transmit All Ones on Copper as an error signal when Fiber interface is down. When this error signal is transmitted, the AIS of the device on the other end is activated, if supported." ::= { csdtf100Entry 13 } csdtf100AISFiber OBJECT-TYPE SYNTAX INTEGER { alarm(1), normal(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Alarm Indication Signal. When equal to alarm(1), this means that the other end has TAOS enabled and is currently transmitting an alarm condition." ::= { csdtf100Entry 14 } csdtf100AISCopper OBJECT-TYPE SYNTAX INTEGER { alarm(1), normal(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Alarm Indication Signal. When equal to alarm(1), this means that the other end has TAOS enabled and is currently transmitting an alarm condition." ::= { csdtf100Entry 15 } csdtf100CopperLoopback OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notSupported(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable loopback on the copper interface. Copper Loopback causes all data that is sent to the copper interface to be transmitted back out the copper interface. NOT SUPPORTED on initial version of the product. " ::= { csdtf100Entry 16 } csdtf100CopperLongHaul OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This variable indicates the current position of the device's long/short haul configuration switch." ::= { csdtf100Entry 17 } csdtf100T1E1 OBJECT-TYPE SYNTAX INTEGER { t1(1), e1(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This variable indicates whether the current device is the T1 or the E1 version." ::= { csdtf100Entry 18 } csdtf100ConfigMode OBJECT-TYPE SYNTAX INTEGER { software(1), hardware(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all configuration control comes from physical switches or jumpers on the device." ::= { csdtf100Entry 19 } csdtf100TPCoax OBJECT-TYPE SYNTAX INTEGER { tp(1), coax(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the connector type installed on the copper interface. For E1 converters, this can be either Twisted Pair or Coax. For T1, it is always Twisted Pair." ::= { csdtf100Entry 20 } csdtf100CopperLineBuildout OBJECT-TYPE SYNTAX INTEGER { e13-0V120ohm(1), e12-37V75ohm(2), t1SH-DSX-0-133ANSIT1403(3), t1SH-DSX-133-266(4), t1SH-DSX-266-399(5), t1SH-DSX-399-533(6), t1SH-DSX-533-655(7), t1SH-DSX-6V(8), t1LH-0dB(9), t1LH-m7-5dB(10), t1LH-m15dB(11), t1LH-m22-5dB(12) } ACCESS read-only STATUS mandatory DESCRIPTION "The characteristics of the copper interface" ::= { csdtf100Entry 21 } csdtf100FiberLoopback OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable loopback on the Fiber interface. Fiber Loopback causes all data that is sent to the Fiber interface to be transmitted back out the Fiber interface." ::= { csdtf100Entry 22 } csdtf100RmtSupported OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Has the value yes(1) if this converter is capable of managing the media converter at the remote end of the fiber." ::= { csdtf100Entry 23 } csdtf100RmtDetected OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Has the value yes(1) if management communcations have been established with a remote media converter. Always no(2) if TAOS is enabled or the remote converter does not support remote management." ::= { csdtf100Entry 24 } csdtf100RmtMRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Remote Marketing Revision. Same as csdtf100MRevision, only for the remote device." ::= { csdtf100Entry 25 } csdtf100RmtSerialNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Serial Number reported by remote device." ::= { csdtf100Entry 26 } csdtf100RmtConnA OBJECT-TYPE SYNTAX CpsConnector ACCESS read-only STATUS mandatory DESCRIPTION "The style of Fiber connector reported by remote device." ::= { csdtf100Entry 27 } csdtf100RmtConnB OBJECT-TYPE SYNTAX CpsConnector ACCESS read-only STATUS mandatory DESCRIPTION "The style of Fiber connector reported by remote device." ::= { csdtf100Entry 28 } csdtf100RmtCopperLink OBJECT-TYPE SYNTAX INTEGER { linkUp(1), linkDown(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Link status of remote Copper Port." ::= { csdtf100Entry 29 } csdtf100RmtFiberLink OBJECT-TYPE SYNTAX INTEGER { linkUp(1), linkDown(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Link status of remote Fiber Port." ::= { csdtf100Entry 30 } csdtf100RmtFault OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Remote Fault status. Value is yes(1) when either CopperLink or FiberLink has value linkDown(2)" ::= { csdtf100Entry 31 } csdtf100RmtTAOSFiber OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Remote Fiber TAOS configuration. Transmit All Ones on Fiber as an error signal when Copper interface is down. When this error signal is transmitted, the AIS of the device on the other end is activated, if supported." ::= { csdtf100Entry 32 } csdtf100RmtTAOSCopper OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Remote Copper TAOS configuration. Transmit All Ones on Copper as an error signal when Fiber interface is down. When this error signal is transmitted, the AIS of the device on the other end is activated, if supported." ::= { csdtf100Entry 33 } csdtf100RmtAISFiber OBJECT-TYPE SYNTAX INTEGER { alarm(1), normal(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Remote Fiber AIS status. Alarm Indication Signal. When equal to alarm(1), this means that the other end has TAOS enabled and is currently transmitting an alarm condition." ::= { csdtf100Entry 34 } csdtf100RmtAISCopper OBJECT-TYPE SYNTAX INTEGER { alarm(1), normal(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Remote Copper AIS status. Alarm Indication Signal. When equal to alarm(1), this means that the other end has TAOS enabled and is currently transmitting an alarm condition." ::= { csdtf100Entry 35 } csdtf100RmtCopperLoopback OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Remote Copper Loopback configuration. Enable loopback on the copper interface. Copper Loopback causes all data that is sent to the copper interface to be transmitted back out the copper interface. NOT SUPPORTED on initial version of the product." ::= { csdtf100Entry 36 } csdtf100RmtCopperLongHaul OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This variable indicates the current position of the remote device's Short/Long haul configuration switch." ::= { csdtf100Entry 37 } csdtf100RmtConfigMode OBJECT-TYPE SYNTAX INTEGER { software(1), hardware(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Remote Configuration Mode. This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all configuration control comes from physical switches or jumpers on the device." ::= { csdtf100Entry 38 } csdtf100RmtTPCoax OBJECT-TYPE SYNTAX INTEGER { tp(1), coax(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the connector type installed on the remote copper interface. For E1 converters, this can be either Twisted Pair or Coax. For T1, it is always Twisted Pair." ::= { csdtf100Entry 39 } csdtf100RmtCopperLineBuildout OBJECT-TYPE SYNTAX INTEGER { e13-0V120ohm(1), e12-37V75ohm(2), t1SH-DSX-0-133ANSIT1403(3), t1SH-DSX-133-266(4), t1SH-DSX-266-399(5), t1SH-DSX-399-533(6), t1SH-DSX-533-655(7), t1SH-DSX-6V(8), t1LH-0dB(9), t1LH-m7-5dB(10), t1LH-m15dB(11), t1LH-m22-5dB(12) } ACCESS read-only STATUS mandatory DESCRIPTION "The electrical characteristics of the remote Copper interface. Values are the same as the values for csdtf100CopperLineBuildout(21)" ::= { csdtf100Entry 40 } csdtf100RmtFiberLoopback OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable loopback on the remote Fiber interface. Fiber Loopback causes all data that is sent to the Fiber interface to be transmitted back out the Fiber interface." ::= { csdtf100Entry 41 } csdtf100CacheClean OBJECT-TYPE SYNTAX INTEGER { clean(1), dirty(2) } ACCESS read-only STATUS mandatory DESCRIPTION "When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2) Device and Management Module cache are not synchronized. The configuration currently displayed by the application has not been validated by the device. The device may need to correct the configuration, in which case the displayed configuration will change." ::= { csdtf100Entry 42 } -- ================================================================ -- Table for the cpsmp110 cpsmp110Table OBJECT-TYPE SYNTAX SEQUENCE OF Cpsmp110Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Sparse table containing one entry for each CPSMP110 IFO (Instant Fail-Over) Power Supply in the stack. indexed by sub-device index, cabinet serial number, and slot. Note that some columns of this table support multiple subdevices, and some do not. For example, there is exactly one SerialNumber for each CPSMP110. No subdevices exist, so the placeholder value 1 is used as the subdevice index. However, a CPSMP110 has zero or more current sensors, which (if they exist) are indexed as different subdevices, starting with 1. Columns with subdevices have names ending in 'Tbl'" ::= { cpsSlotDetail 10 } cpsmp110Entry OBJECT-TYPE SYNTAX Cpsmp110Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Status and configuration entries for a single CPSMP100" INDEX { cpsmp110SubDeviceIndex, cpsmp110BiaIndex, cpsmp110SlotIndex } ::= { cpsmp110Table 1 } Cpsmp110Entry ::= SEQUENCE { cpsmp110SubDeviceIndex INTEGER, cpsmp110BiaIndex INTEGER, cpsmp110SlotIndex INTEGER, cpsmp110Groups DisplayString, cpsmp110MRevision INTEGER, cpsmp110CfgMatch INTEGER, cpsmp110SerialNumber INTEGER, cpsmp110ConfigMode INTEGER, cpsmp110MasterTempFault INTEGER, cpsmp110MasterCurrentFault INTEGER, cpsmp110MasterFanFault INTEGER, cpsmp110FirmwareRevision INTEGER, cpsmp110PSSupplyTbl INTEGER, cpsmp110PSRoleTbl INTEGER, cpsmp110PSReadyTbl INTEGER, cpsmp110PSInUseTbl INTEGER, cpsmp110TemperatureTbl INTEGER, cpsmp110CurrentTbl INTEGER, cpsmp110FanStatusTbl INTEGER, cpsmp110TempFaultTbl INTEGER, cpsmp110CurrFaultTbl INTEGER, cpsmp110PSCount INTEGER, cpsmp110TempSensorCount INTEGER, cpsmp110CurrSensorCount INTEGER, cpsmp110FanCount INTEGER, cpsmp110CacheClean INTEGER } cpsmp110SubDeviceIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Generally, individual devices in this MIB are distinguished by BiaIndex and SlotIndex. This device differs from many in that it contains multiple subdevices (in this case, fans, temperature sensors, current sensors, and power supplies). The number of subdevices varies with the manufactured configuration. Subdevices within devices are indexed by BiaIndex, SlotIndex, and SubDeviceIndex. When the subdevice column is read from the table, the value '1' is always returned." ::= { cpsmp110Entry 1 } cpsmp110BiaIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number (BIA) of the cabinet in which the device is installed. There are no subdevices for this value, so the placeholder value 1 is always used for that index." ::= { cpsmp110Entry 2 } cpsmp110SlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The slot in which the device is installed. Power Supplies occupy special slots numbered 125 and higher. There are no subdevices for this value, so the placeholder value 1 is always used for that index." ::= { cpsmp110Entry 3 } cpsmp110Groups OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent can be instructed to apply configuration changes simultaneously to all group members rather than to individual devices. Every Groups string has three automatically defined implied values: 1) The model family of the device, e.g. 'CPSMP110' 2) The serial number of the cabinet in which the device is installed, in decimal with no leading zeroes, e.g. '12345', and 3) same as 2, with the slot in which the device is installed appended, enclosed in square brackets. e.g. '12345[9]' There are no subdevices for this value, so the placeholder value 1 is always used for that index." ::= { cpsmp110Entry 4 } cpsmp110MRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The marketing revision of this device. There are no subdevices for this value, so the placeholder value 1 is always used for that index." ::= { cpsmp110Entry 5 } cpsmp110CfgMatch OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notApplicable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) indicates that cpsGroupCtrl.0 is null and therefore no comparison was performed. There are no subdevices for this value, so the placeholder value 1 is always used for that index." ::= { cpsmp110Entry 6 } cpsmp110SerialNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number of this device. There are no subdevices for this value, so the placeholder value 1 is always used for that index." ::= { cpsmp110Entry 7 } cpsmp110ConfigMode OBJECT-TYPE SYNTAX INTEGER { software(1), hardware(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This device may have a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all configuration control comes from physical switches or jumpers on the device. There are no subdevices for this value, so the placeholder value 1 is always used for that index." ::= { cpsmp110Entry 8 } cpsmp110MasterTempFault OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The master temperature fault indicator for this device. A value of yes(1) indicates that at least one temperature sensor encountered a fault condition since the last time the device was queried by the management module. The statuses of individual temperature sensors can be found in cpsmp110TemperatureTbl. Note that in the unusual case that a sensor spikes (i.e. encounters a fault, and then quickly returns to normal), it will be difficult to determine which sensor faulted. However, the fact that any sensor faulted is sufficient cause to examine the cabinet further. There are no subdevices for this value, so the placeholder value 1 is always used for that index." ::= { cpsmp110Entry 9 } cpsmp110MasterCurrentFault OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The master current fault indicator for this device. A value of yes(1) indicates that at least one current sensor encountered a fault condition since the last time the device was queried by the management module. The statuses of individual current sensors can be found in cpsmp110CurrentTbl. Note that in the unusual case that a sensor spikes (i.e. encounters a fault, and then quickly returns to normal), it will be difficult to determine which sensor faulted. However, the fact that any sensor faulted is sufficient cause to examine the cabinet further. There are no subdevices for this value, so the placeholder value 1 is always used for that index." ::= { cpsmp110Entry 10 } cpsmp110MasterFanFault OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The master fan fault indicator for this device. A value of yes(1) indicates that at least one fan current sensor encountered a fault condition since the last time the device was queried by the management module. The statuses of individual fan current sensors can be found in cpsmp110FanStatusTbl. Note that in the unusual case that a sensor spikes (i.e. encounters a fault, and then quickly returns to normal), it will be difficult to determine which sensor faulted. However, the fact that any sensor faulted is sufficient cause to examine the cabinet further. There are no subdevices for this value, so the placeholder value 1 is always used for that index." ::= { cpsmp110Entry 11 } cpsmp110FirmwareRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The firmware revision level for this device. There are no subdevices for this value, so the placeholder value 1 is always used for that index." ::= { cpsmp110Entry 12 } cpsmp110PSSupplyTbl OBJECT-TYPE SYNTAX INTEGER { ac(1), dc(2), reserved3(3), reserved4(4), notInstalled(5) } ACCESS read-only STATUS mandatory DESCRIPTION "The supply voltage that this unit is designed to accept. If AC(1), the supply accepts VAC. If DC(2), the supply accepts. A single CPSMP110 control unit can support multiple subdevices of this type. There will be one entry per subdevice." ::= { cpsmp110Entry 13 } cpsmp110PSRoleTbl OBJECT-TYPE SYNTAX INTEGER { master(1), slave(2), shared(3), notInstalled(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Some power supplies support a Master/Slave relationship: When one power supply is set to master(1) and the other is set to slave(2), the master will supply all power to the cabinet, and the slave will take over if the master stops supplying power. This is useful when (for example) one supply is attached to a wall socket and the other to a battery backup. The cabinet can be directed to only draw power from batteries when there is no alternative. When both power supplies are set to master(1), the results are determined automatically. WARNING: It is up to the system administrator to ensure that at least one power supply is set to master(1). It is illegal to set all power supplies to slave(2). If this occurs, the cabinet may lose all power under certain circumstances, even if power is available. In some cases, the Master/Slave relationship cannot be configured via management; it is determined by other means, such as the slot locations in which the supplies are installed, or switches on the supplies. In this case, attempts to change the value of this variable from management will be ignored. The ConfigMode variable will have the value hardware(2) in this case. If a supply does not support (or can disable) Master/Slave functionality, the value shared(3) is returned. In this case, all ready power supplies share the load evenly. A single CPSMP110 control unit can support multiple subdevices of this type." ::= { cpsmp110Entry 14 } cpsmp110PSReadyTbl OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The readiness of this power supply module. A value of yes(1) indicates the module is ready to supply power to the cabinet. A value of no(2) indicates that the supply has no output power to offer, either because it is malfunctioning or because it has no input power. A single CPSMP110 control unit can support multiple subdevices of this type." ::= { cpsmp110Entry 15 } cpsmp110PSInUseTbl OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The use status of this power supply module. A value of yes(1) indicates the module is supplying power to the cabinet. This variable is useful in configurations where master/slave role functionality is supported to determine whether the Master or the Slave is active. In shared configurations, the value of PSReadyTbl is strongly preferred as an indication of the status of the supply. A single CPSMP110 control unit can support multiple subdevices of this type." ::= { cpsmp110Entry 16 } cpsmp110TemperatureTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The temperature, in tenths of degrees centigrade, read by this temperature sensor. A single CPSMP110 control unit can support multiple subdevices of this type." ::= { cpsmp110Entry 17 } cpsmp110CurrentTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The current, in milliwatts, read by this current sensor. A single CPSMP110 control unit can support multiple subdevices of this type." ::= { cpsmp110Entry 18 } cpsmp110FanStatusTbl OBJECT-TYPE SYNTAX INTEGER { ok(1), fault(2), notInstalled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The status of a fan. A value of fault(2) indicates that the control unit has detected a problem with the fan, usually that it is is drawing excessive current. A single CPSMP110 control unit can support multiple subdevices of this type." ::= { cpsmp110Entry 19 } cpsmp110TempFaultTbl OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Each entry in this column corresponds to an entry with the same indices in cpsmp110TemperatureTable. It indicates whether or not the temperature read by the sensor is within the acceptable range. A single CPSMP110 control unit can support multiple subdevices of this type." ::= { cpsmp110Entry 20 } cpsmp110CurrFaultTbl OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Each entry in this column corresponds to an entry with the same indices in cpsmp110CurrentTable. It indicates whether or not the current read by the sensor is within the acceptable range. A single CPSMP110 control unit can support multiple subdevices of this type." ::= { cpsmp110Entry 21 } cpsmp110PSCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of power supplies supported in this configuration." ::= { cpsmp110Entry 22 } cpsmp110TempSensorCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of temperature sensors supported in this device." ::= { cpsmp110Entry 23 } cpsmp110CurrSensorCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of current sensors supported in this device." ::= { cpsmp110Entry 24 } cpsmp110FanCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of fans supported in this device." ::= { cpsmp110Entry 25 } cpsmp110CacheClean OBJECT-TYPE SYNTAX INTEGER { clean(1), dirty(2) } ACCESS read-only STATUS mandatory DESCRIPTION "When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2) Device and Management Module cache are not synchronized. The configuration currently displayed by the application has not been validated by the device. The device may need to correct the configuration, in which case the displayed configuration will change." ::= { cpsmp110Entry 26 } -- ================================================================ -- Table for the cbftf100 cbftf100Table OBJECT-TYPE SYNTAX SEQUENCE OF Cbftf100Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Sparse table containing one entry for each CBFTF100 switch in the stack. Indexed by sub-device index, cabinet serial number, and slot. Note that some columns of this table support multiple subdevices, and some do not. For example, there is exactly one SerialNumber for each CBFTF100. No subdevices exist, so the placeholder value 1 is used as the subdevice index. However, a CBFTF100 has multiple switch ports, which are indexed as different subdevices, starting with 1. Columns with subdevices have names ending in 'Tbl'" ::= { cpsSlotDetail 11 } cbftf100Entry OBJECT-TYPE SYNTAX Cbftf100Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Status and configuration entries for a single CBFTF100" INDEX { cbftf100SubDeviceIndex, cbftf100BiaIndex, cbftf100SlotIndex } ::= { cbftf100Table 1 } Cbftf100Entry ::= SEQUENCE { cbftf100SubDeviceIndex INTEGER, cbftf100BiaIndex INTEGER, cbftf100SlotIndex INTEGER, cbftf100Groups DisplayString, cbftf100MRevision INTEGER, cbftf100CfgMatch INTEGER, cbftf100SerialNumber INTEGER, cbftf100ConfigMode INTEGER, cbftf100FirmwareRevision INTEGER, cbftf100SelfTestFailed INTEGER, cbftf100SpanningTree INTEGER, cbftf100MirrorCfg INTEGER, cbftf100SACMasterCfg INTEGER, cbftf100FormFactor INTEGER, cbftf100AutoNegotTbl INTEGER, cbftf100FullDuplexTbl INTEGER, cbftf100100MbpsTbl INTEGER, cbftf100Adv10HDXTbl INTEGER, cbftf100Adv10FDXTbl INTEGER, cbftf100Adv100HDXTbl INTEGER, cbftf100Adv100FDXTbl INTEGER, cbftf100CrossTbl INTEGER, cbftf100PauseCfgTbl INTEGER, cbftf100PauseStatTbl INTEGER, cbftf100FarEndFaultTbl INTEGER, cbftf100ConnectorTbl INTEGER, cbftf100SACCfgTbl INTEGER, cbftf100SACStatTbl INTEGER, cbftf100MirrorSelTbl INTEGER, cbftf100MirrorInTbl INTEGER, cbftf100MirrorOutTbl INTEGER, cbftf100LinkTbl INTEGER, cbftf100PortCount INTEGER, cbftf100LinkPassThrough INTEGER, cbftf100CacheClean INTEGER, cbftf100RedundantPath INTEGER } cbftf100SubDeviceIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Generally, individual devices in this MIB are distinguished by BiaIndex and SlotIndex. This device differs from many in that it contains multiple subdevices (in this case, switch ports). The number of subdevices varies with the manufactured configuration. Subdevices within devices are indexed by BiaIndex, SlotIndex, and SubDeviceIndex. When the subdevice column is read from the table, the value '1' is always returned." ::= { cbftf100Entry 1 } cbftf100BiaIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number (BIA) of the cabinet in which the device is installed. There are no subdevices for this value, so the placeholder value 1 is always used for that index." ::= { cbftf100Entry 2 } cbftf100SlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The slot in which the device is installed. Power Supplies occupy special slots numbered 125 and higher. There are no subdevices for this value, so the placeholder value 1 is always used for that index." ::= { cbftf100Entry 3 } cbftf100Groups OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent can be instructed to apply configuration changes simultaneously to all group members rather than to individual devices. Every Groups string has three automatically defined implied values: 1) The model family of the device, e.g. 'cbftf100' 2) The serial number of the cabinet in which the device is installed, in decimal with no leading zeroes, e.g. '12345', and 3) same as 2, with the slot in which the device is installed appended, enclosed in square brackets. e.g. '12345[9]' There are no subdevices for this value, so the placeholder value 1 is always used for that index." ::= { cbftf100Entry 4 } cbftf100MRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The marketing revision of this device. There are no subdevices for this value, so the placeholder value 1 is always used for that index." ::= { cbftf100Entry 5 } cbftf100CfgMatch OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notApplicable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) indicates that cpsGroupCtrl.0 is null and therefore no comparison was performed. There are no subdevices for this value, so the placeholder value 1 is always used for that index." ::= { cbftf100Entry 6 } cbftf100SerialNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number of this device. There are no subdevices for this value, so the placeholder value 1 is always used for that index." ::= { cbftf100Entry 7 } cbftf100ConfigMode OBJECT-TYPE SYNTAX INTEGER { software(1), hardware(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This device may have a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all configuration control comes from physical switches or jumpers on the device. There are no subdevices for this value, so the placeholder value 1 is always used for that index." ::= { cbftf100Entry 8 } cbftf100FirmwareRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The firmware revision level for this device. There are no subdevices for this value, so the placeholder value 1 is always used for that index." ::= { cbftf100Entry 9 } cbftf100SelfTestFailed OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This variable indicates the status of the pass/fail power on test. If the power on test fails, normal operation of this device is probably not possible. " ::= { cbftf100Entry 10 } cbftf100SpanningTree OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notSupported(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows the agent to enable or disable Spanning Tree if it is supported. Not all versions of the hardware support Spanning Tree." ::= { cbftf100Entry 11 } cbftf100MirrorCfg OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notSupported(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Global enable/disable for mirror port functionality. When this variable is set to disabled, the values of cbftf100MirrorSelTbl, cbftf100MirrorInTbl, and cbftf100MirrorOutTbl are ignored." ::= { cbftf100Entry 12 } cbftf100SACMasterCfg OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Global enable/disable for Source Address Change detection functionality. When this variable is set to disabled the values in cbtf100SACCfgTbl are ignored." ::= { cbftf100Entry 13 } cbftf100FormFactor OBJECT-TYPE SYNTAX INTEGER { s1W2a(1), s1W1N2a(2), s1W1N1a(3), s2W2N4a(4), s2W1N5a(5) } ACCESS read-only STATUS mandatory DESCRIPTION "A code corresponding to a physical configuration of the product. This code indicates the number of slots occupied and the number of physical connectors present. In the labels for the values above, s indicates the number of slots occupied, W is a count of Wide port positions (which can built as almost any type of connector), and N is a count of narrow port positions (which are typically twisted pair ports). The lowercase letter at the end differentiates different form factors that would otherwise have identical descriptions under this limited scheme." ::= { cbftf100Entry 14 } cbftf100AutoNegotTbl OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notSupported(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Enables or disables autonegtiation of link speed and duplex for twisted pair ports. Not supported on Fiber ports. There are multiple subdevices in this table, numbering one entry per port." ::= { cbftf100Entry 15 } cbftf100FullDuplexTbl OBJECT-TYPE SYNTAX INTEGER { fullDuplex(1), halfDuplex(2), negotiating(3) } ACCESS read-write STATUS mandatory DESCRIPTION "In most cases this is a configuration setting that controls the duplex mode; fullDuplex is full duplex and halfDuplex is half duplex. On twisted pair ports with autonegotiation enabled, this is a status indication showing the duplex value decided upon during the negotiation. When link is down, autonegotiation has not been completed yet, and the duplex setting is therefore unknown and the value is negotiating(3). There are multiple subdevices in this table, numbering one entry per port." ::= { cbftf100Entry 16 } cbftf100100MbpsTbl OBJECT-TYPE SYNTAX INTEGER { mbps100(1), mbps10(2), negotiating(3) } ACCESS read-write STATUS mandatory DESCRIPTION "In most cases this is a configuration setting that controls the link speed. On twisted pair ports with autonegotiation enabled, this is a status indication showing the link speed decided upon during negotiation. When link is down, autonegotiation has not been completed yet, and the link speed is therefore unknown and is negotiating(3). This variable is an indicator only for fiber ports; all fiber ports report mbps100(1) at all times. There are multiple subdevices in this table, numbering one entry per port." ::= { cbftf100Entry 17 } cbftf100Adv10HDXTbl OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notSupported(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This configuration setting controls whether or not each port advertises willingness to connect at 10Mbps, half duplex. This setting is not supported on fiber ports, and is ignored when autonegotiation is disabled. There are multiple subdevices in this table, numbering one entry per port." ::= { cbftf100Entry 18 } cbftf100Adv10FDXTbl OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notSupported(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This configuration setting controls whether or not each port advertises willingness to connect at 10Mbps, full duplex. This setting is not supported on fiber ports, and is ignored when autonegotiation is disabled. There are multiple subdevices in this table, numbering one entry per port." ::= { cbftf100Entry 19 } cbftf100Adv100HDXTbl OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notSupported(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This configuration setting controls whether or not each port advertises willingness to connect at 100Mbps, half duplex. This setting is not supported on fiber ports, and is ignored when autonegotiation is disabled. There are multiple subdevices in this table, numbering one entry per port." ::= { cbftf100Entry 20 } cbftf100Adv100FDXTbl OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notSupported(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This configuration setting controls whether or not each port advertises willingness to connect at 100Mbps, full duplex. This setting is not supported on fiber ports, and is ignored when autonegotiation is disabled. There are multiple subdevices in this table, numbering one entry per port." ::= { cbftf100Entry 21 } cbftf100CrossTbl OBJECT-TYPE SYNTAX INTEGER { auto(1), mdi(2), mdix(3), notSupported(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Configuration setting for copper TX/RX pair correction. A setting of auto(1) causes the port to automatically correct TX/RX pairs if necessary. If autonegotiation is disabled on the port, the auto(1) setting is not supported. A setting of mdi(2) causes the TX/RX pairs to be passed straight through with no correction. A setting of mdix(3) causes the TX/RX pairs to be swapped. This setting is supprted for copper ports only; a read-only value of notSupported(4) is returned for fiber ports. There are multiple subdevices in this table, numbering one entry per port." ::= { cbftf100Entry 22 } cbftf100PauseCfgTbl OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notSupported(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The Pause feature allows Ethernet MACs that support it to send data pacing 'Pause' messages to each other. A setting of enabled(1) causes this port to advertise pause capability and a setting of disabled(2) disables pause capability advertising. On fiber ports, a read-only value of notSupported(3) is returned. There are multiple subdevices in this table, numbering one entry per port." ::= { cbftf100Entry 23 } cbftf100PauseStatTbl OBJECT-TYPE SYNTAX INTEGER { paused(1), normal(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The Pause feature allows Ethernet MACs that support it to send data pacing 'Pause' messages to each other. A value of paused(1) indicated the port is in a paused state, and a value of normal(2) indicates the port is operating normally. There are multiple subdevices in this table, numbering one entry per port." ::= { cbftf100Entry 24 } cbftf100FarEndFaultTbl OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notSupported(3) } ACCESS read-write STATUS mandatory DESCRIPTION "When Far End Fault is set to enabled(1), a loss of link on receive will cause the transmitter to shut down, in order to inform the device at the far end of the link that a fault has occurred. Far End Fault is only supported on fiber ports. A read-only value of notSupported(3) is returned for copper ports. There are multiple subdevices in this table, numbering one entry per port." ::= { cbftf100Entry 25 } cbftf100ConnectorTbl OBJECT-TYPE SYNTAX CpsConnector ACCESS read-only STATUS mandatory DESCRIPTION "The style of connectors built into each port of this device. There are multiple subdevices in this table, numbering one entry per port." ::= { cbftf100Entry 26 } cbftf100SACCfgTbl OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This configuration setting controls whether changes in source MAC address are reported. When set to enabled(1), a change in MAC address will result in a momentary change in the value of SACStatTbl from same(2) to changed(1) and back, and the transmission of a trap, if the management module is so configured. There are multiple subdevices in this table, numbering one entry per port." ::= { cbftf100Entry 27 } cbftf100SACStatTbl OBJECT-TYPE SYNTAX INTEGER { changed(1), same(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This status value indicates whether or not the source MAC address attached to this port changed in the last polling period. This value tends to change quite quickly; therefore, the 'ERROR' traps that are sent when SAC is detected are a much more reliable indicator. There are multiple subdevices in this table, numbering one entry per port." ::= { cbftf100Entry 28 } cbftf100MirrorSelTbl OBJECT-TYPE SYNTAX INTEGER { mirror(1), normal(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This configuration setting allows a mirror port to be selected. The selected port will re-transmit copies of all packets transmitted on ports whose MirrorOutTbl value is set to mirrorOut(1), and will also transmit copies of all packets received by all ports whose MirrorInTbl value is set to mirrorIn(1). It is recommended that a maximum of one MirrorSelTbl, one MirrorInTbl, and one MirrorOutTbl port be selected at once, since the switch may have trouble handling the traffic that can result from other configurations. There are multiple subdevices in this table, numbering one entry per port." ::= { cbftf100Entry 29 } cbftf100MirrorInTbl OBJECT-TYPE SYNTAX INTEGER { mirrorIn(1), normal(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This configuration setting allows a mirror source port to be selected. All packets received on each port with a MirrorInTbl setting of mirrorIn(1) will be retransmitted on all ports whose MirrorSelTbl setting is mirror(1). It is recommended that a maximum of one MirrorSelTbl, one MirrorInTbl, and one MirrorOutTbl port be selected at once, since the switch may have trouble handling the traffic that can result from other configurations. There are multiple subdevices in this table, numbering one entry per port." ::= { cbftf100Entry 30 } cbftf100MirrorOutTbl OBJECT-TYPE SYNTAX INTEGER { mirrorOut(1), normal(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This configuration setting allows a mirror source port to be selected. All packets transmitted on each port with a MirrorInTbl setting of mirrorOut(1) will be retransmitted on all ports whose MirrorSelTbl setting is mirror(1). It is recommended that a maximum of one MirrorSelTbl, one MirrorInTbl, and one MirrorOutTbl port be selected at once, since the switch may have trouble handling the traffic that can result from other configurations. There are multiple subdevices in this table, numbering one entry per port." ::= { cbftf100Entry 31 } cbftf100LinkTbl OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This table contains the link status of each port in the switch. There are multiple subdevices in this table, numbering one entry per port." ::= { cbftf100Entry 32 } cbftf100PortCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A count of the switch ports in this device. i.e. the maximum subdevice index supported by this switch." ::= { cbftf100Entry 33 } cbftf100LinkPassThrough OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notSupported(3) } ACCESS read-write STATUS mandatory DESCRIPTION "If Link Passthrough is enabled on a port, loss of link on the opposite port will be propegated through to this port so that the switch does not prevent one end device from detecting loss of link on the opposite end device. Far end fault is only supported on copper ports and only in switch configurations that have exactly two ports." ::= { cbftf100Entry 34 } cbftf100CacheClean OBJECT-TYPE SYNTAX INTEGER { clean(1), dirty(2) } ACCESS read-only STATUS mandatory DESCRIPTION "When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2) Device and Management Module cache are not synchronized. The configuration currently displayed by the application has not been validated by the device. The device may need to correct the configuration, in which case the displayed configuration will change." ::= { cbftf100Entry 35 } cbftf100RedundantPath OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notSupported(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This variable shows the status of the redundant fiber capability. If the value is enabled(1), this means that the hardware switch to enable redundant fiber is on, and the two fiber ports on the device are presumed to be connected to the same remote device. Even if both fibers have link, traffic flows to and from that device through only one of the two fiber pairs at once. This provides a redundant path should one of the fibers be compromised. If the value is disabled(2), the hardware switch to enable redundant fiber is off, and the two fiber ports on the device pass traffic normally (i.e. independently and simultaneously). If the value is notSupported(3), the device does not have redundant fiber capability." ::= { cbftf100Entry 36 } -- =================================================================== -- Table for a CETCT100 media converter cetct100Table OBJECT-TYPE SYNTAX SEQUENCE OF Cetct100Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Sparse table containing one entry for each CETCT100 10Mbps Twisted-Pair to Fiber Ethernet Media Converter in the stack, indexed by cabinet serial number and slot." ::= { cpsSlotDetail 12 } cetct100Entry OBJECT-TYPE SYNTAX Cetct100Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Status and configuration entries for a single CETCT100" INDEX { cetct100BiaIndex, cetct100SlotIndex } ::= { cetct100Table 1 } Cetct100Entry ::= SEQUENCE { cetct100BiaIndex INTEGER, cetct100SlotIndex INTEGER, cetct100Groups DisplayString, cetct100MRevision INTEGER, cetct100CfgMatch INTEGER, cetct100SerialNumber INTEGER, cetct100ConfigMode INTEGER, cetct100FirmwareRevision INTEGER, cetct100TPLink INTEGER, cetct100Collision INTEGER, cetct100CoaxActivity INTEGER, cetct100TPActivity INTEGER, cetct100CollisionsPerMinute INTEGER, cetct100CollisionsPerHour INTEGER, cetct100ConnB INTEGER, cetct100ConnA INTEGER, cetct100CacheClean INTEGER } cetct100BiaIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number (BIA) of the cabinet in which the device is installed" ::= { cetct100Entry 1 } cetct100SlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The slot in which the device is installed" ::= { cetct100Entry 2 } cetct100Groups OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent can be instructed to apply configuration changes simultaneously to all group members rather than to individual devices. Every Groups string has three automatically defined implied values: 1) The model family of the device, e.g. 'CETCT100' 2) The serial number of the cabinet in which the device is installed, in decimal with no leading zeroes, e.g. '12345', and 3) same as 2, with the slot in which the device is installed appended, enclosed in square brackets. e.g. '12345[9]'" ::= { cetct100Entry 3 } cetct100MRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The marketing revision of this device" ::= { cetct100Entry 4 } cetct100CfgMatch OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notApplicable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) indicates that cpsGroupCtrl.0 is null and therefore no comparison was performed." ::= { cetct100Entry 5 } cetct100SerialNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number of this device" ::= { cetct100Entry 6 } cetct100ConfigMode OBJECT-TYPE SYNTAX INTEGER { software(1), hardware(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all configuration control comes from physical switches or jumpers on the device." ::= { cetct100Entry 7 } cetct100FirmwareRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The firmware revision level for this device." ::= { cetct100Entry 8 } cetct100TPLink OBJECT-TYPE SYNTAX INTEGER { linkUp(1), linkDown(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of Copper Link for this device" ::= { cetct100Entry 9 } cetct100Collision OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This status variable indicates whether or not an Ethernet collision occurred during the most recent polling cycle." ::= { cetct100Entry 10 } cetct100CoaxActivity OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This status variable indicates whether or not Ethernet traffic was detected on the Coax interface during the most recent polling cycle." ::= { cetct100Entry 11 } cetct100TPActivity OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This status variable indicates whether or not Ethernet traffic was detected on the Twisted Pair interface during the most recent polling cycle." ::= { cetct100Entry 12 } cetct100CollisionsPerMinute OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of Ethernet collisions that occurred during the most recently completed measured minute. Every 60 seconds, the device moves its previous collision count into this variable, and restarts the counter at zero." ::= { cetct100Entry 13 } cetct100CollisionsPerHour OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of Ethernet collisions that occurred during the most recently completed measured hour. Every 60 minutes, the device moves its previous collision count into this variable, and restarts the counter at zero." ::= { cetct100Entry 14 } cetct100ConnA OBJECT-TYPE SYNTAX CpsConnector ACCESS read-only STATUS mandatory DESCRIPTION "The style of media connector built into this device." ::= { cetct100Entry 15 } cetct100ConnB OBJECT-TYPE SYNTAX CpsConnector ACCESS read-only STATUS mandatory DESCRIPTION "The style of media connector built into this device." ::= { cetct100Entry 16 } cetct100CacheClean OBJECT-TYPE SYNTAX INTEGER { clean(1), dirty(2) } ACCESS read-only STATUS mandatory DESCRIPTION "When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2) Device and Management Module cache are not synchronized. The configuration currently displayed by the application has not been validated by the device. The device may need to correct the configuration, in which case the displayed configuration will change." ::= { cetct100Entry 17 } --===================================================================== -- Table for the ccscf100 ccscf100Table OBJECT-TYPE SYNTAX SEQUENCE OF Ccscf100Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Sparse table containing one entry for each ccscf100 T3/E3 Copper to Fiber Media Converter in the stack, indexed by cabinet serial number and slot." ::= { cpsSlotDetail 13 } ccscf100Entry OBJECT-TYPE SYNTAX Ccscf100Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Status and configuration entries for a single ccscf100" INDEX { ccscf100BiaIndex, ccscf100SlotIndex } ::= { ccscf100Table 1 } Ccscf100Entry ::= SEQUENCE { ccscf100BiaIndex INTEGER, ccscf100SlotIndex INTEGER, ccscf100Groups DisplayString, ccscf100MRevision INTEGER, ccscf100CfgMatch INTEGER, ccscf100SerialNumber INTEGER, ccscf100ConfigMode INTEGER, ccscf100FiberLink INTEGER, ccscf100CopperLink INTEGER, ccscf100AISFiber INTEGER, ccscf100AISCopper INTEGER, ccscf100DS3LineBuildout INTEGER, ccscf100E3DS3 INTEGER, ccscf100CopperLoopback INTEGER, ccscf100FiberLoopback INTEGER, ccscf100ConnA INTEGER, ccscf100ConnB INTEGER, ccscf100CacheClean INTEGER } ccscf100BiaIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number (BIA) of the cabinet in which the device is installed" ::= { ccscf100Entry 1 } ccscf100SlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The slot in which the device is installed" ::= { ccscf100Entry 2 } ccscf100Groups OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent can be instructed to apply configuration changes simultaneously to all group members rather than to individual devices. Every Groups string has three automatically defined implied values: 1) The model family of the device, e.g. 'ccscf100' 2) The serial number of the cabinet in which the device is installed, in decimal with no leading zeroes, e.g. '12345', and 3) same as 2, with the slot in which the device is installed appended, enclosed in square brackets. e.g. '12345[9]'" ::= { ccscf100Entry 3 } ccscf100MRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The marketing revision of this device" ::= { ccscf100Entry 4 } ccscf100CfgMatch OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), inactive(3) } ACCESS read-only STATUS mandatory DESCRIPTION "yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) indicates that cpsGroupCtrl.0 is null and therefore no comparison was performed." ::= { ccscf100Entry 5 } ccscf100SerialNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number of this device" ::= { ccscf100Entry 6 } ccscf100ConfigMode OBJECT-TYPE SYNTAX INTEGER { software(1), hardware(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all configuration control comes from physical switches or jumpers on the device." ::= { ccscf100Entry 7 } ccscf100FiberLink OBJECT-TYPE SYNTAX INTEGER { linkUp(1), linkDown(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of Fiber Link for this device" ::= { ccscf100Entry 8 } ccscf100CopperLink OBJECT-TYPE SYNTAX INTEGER { linkUp(1), linkDown(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of Copper Link for this device" ::= { ccscf100Entry 9 } ccscf100AISFiber OBJECT-TYPE SYNTAX INTEGER { alarm(1), normal(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Alarm Indication Signal. When equal to alarm(1), this means that the other end has TAOS enabled and is currently transmitting an alarm condition." ::= { ccscf100Entry 10 } ccscf100AISCopper OBJECT-TYPE SYNTAX INTEGER { alarm(1), normal(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Alarm Indication Signal. When equal to alarm(1), this means that the other end has TAOS enabled and is currently transmitting an alarm condition." ::= { ccscf100Entry 11 } ccscf100DS3LineBuildout OBJECT-TYPE SYNTAX INTEGER { boost(1), normal(2), notSupported(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The characteristics of the copper interface" ::= { ccscf100Entry 12 } ccscf100E3DS3 OBJECT-TYPE SYNTAX INTEGER { e3(1), ds3(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This variable indicates whether the current device is the T1 or the E1 version." ::= { ccscf100Entry 13 } ccscf100CopperLoopback OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable loopback on the copper interface." ::= { ccscf100Entry 14 } ccscf100FiberLoopback OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable loopback on the copper interface." ::= { ccscf100Entry 15 } ccscf100ConnA OBJECT-TYPE SYNTAX CpsConnector ACCESS read-only STATUS mandatory DESCRIPTION "The style of Fiber connector built into this device" ::= { ccscf100Entry 16 } ccscf100ConnB OBJECT-TYPE SYNTAX CpsConnector ACCESS read-only STATUS mandatory DESCRIPTION "The style of Copper connector built into this device" ::= { ccscf100Entry 17 } ccscf100CacheClean OBJECT-TYPE SYNTAX INTEGER { clean(1), dirty(2) } ACCESS read-only STATUS mandatory DESCRIPTION "When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2) Device and Management Module cache are not synchronized. The configuration currently displayed by the application has not been validated by the device. The device may need to correct the configuration, in which case the displayed configuration will change." ::= { ccscf100Entry 18 } -- ================================================================== -- Table for a cfetf105 slide in card. cfetf105Table OBJECT-TYPE SYNTAX SEQUENCE OF Cfetf105Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Sparse table containing one entry for each CFTEF105 100Mbps Twisted-Pair to Fiber Ethernet Media Converter in the stack, indexed by cabinet serial number and slot." ::= { cpsSlotDetail 14 } cfetf105Entry OBJECT-TYPE SYNTAX Cfetf105Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Status and configuration entries for a single CFETF105" INDEX { cfetf105BiaIndex, cfetf105SlotIndex } ::= { cfetf105Table 1 } Cfetf105Entry ::= SEQUENCE { cfetf105BiaIndex INTEGER, cfetf105SlotIndex INTEGER, cfetf105Groups DisplayString, cfetf105MRevision INTEGER, cfetf105CfgMatch INTEGER, cfetf105SerialNumber INTEGER, cfetf105ConnA INTEGER, cfetf105ConnB INTEGER, cfetf105TPLink INTEGER, cfetf105FiberLink INTEGER, cfetf105AutoNegot INTEGER, cfetf105LinkPassThrough INTEGER, cfetf105AutoCross INTEGER, cfetf105TPActivity INTEGER, cfetf105FiberActivity INTEGER, cfetf105ConfigMode INTEGER, cfetf105CacheClean INTEGER } cfetf105BiaIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number (BIA) of the cabinet in which the device is installed" ::= { cfetf105Entry 1 } cfetf105SlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The slot in which the device is installed" ::= { cfetf105Entry 2 } cfetf105Groups OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent can be instructed to apply configuration changes simultaneously to all group members rather than to individual devices. Every Groups string has three automatically defined implied values: 1) The model family of the device, e.g. 'CFETF105' 2) The serial number of the cabinet in which the device is installed, in decimal with no leading zeroes, e.g. '12345', and 3) same as 2, with the slot in which the device is installed appended, enclosed in square brackets. e.g. '12345[9]'" ::= { cfetf105Entry 3 } cfetf105MRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The marketing revision of this device" ::= { cfetf105Entry 4 } cfetf105CfgMatch OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notApplicable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) indicates that cpsGroupCtrl.0 is null and therefore no comparison was performed." ::= { cfetf105Entry 5 } cfetf105SerialNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number of this device" ::= { cfetf105Entry 6 } cfetf105ConnA OBJECT-TYPE SYNTAX CpsConnector ACCESS read-only STATUS mandatory DESCRIPTION "The style of Fiber connector built into this device" ::= { cfetf105Entry 7 } cfetf105ConnB OBJECT-TYPE SYNTAX CpsConnector ACCESS read-only STATUS mandatory DESCRIPTION "The style of Copper connector built into this device" ::= { cfetf105Entry 8 } cfetf105TPLink OBJECT-TYPE SYNTAX INTEGER { linkUp(1), linkDown(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of Twisted Pair Link for this device" ::= { cfetf105Entry 9 } cfetf105FiberLink OBJECT-TYPE SYNTAX INTEGER { linkUp(1), linkDown(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of Fiber Link for this device" ::= { cfetf105Entry 10 } cfetf105AutoNegot OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/Disable Autonegotiation" ::= { cfetf105Entry 11 } cfetf105LinkPassThrough OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/Disable for Link Pass Through, a feature that causes loss of link on one side of a media converter to be passed through to the other side, so that upstream equipment can see the fault condition." ::= { cfetf105Entry 12 } cfetf105AutoCross OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/Disable for automatic copper TX/RX pair correction" ::= { cfetf105Entry 13 } cfetf105TPActivity OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notSupported(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Network traffic indicator for Copper side of this device" ::= { cfetf105Entry 14 } cfetf105FiberActivity OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notSupported(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Network traffic indicator for Fiber side of this device" ::= { cfetf105Entry 15 } cfetf105ConfigMode OBJECT-TYPE SYNTAX INTEGER { software(1), hardware(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all configuration control comes from physical switches or jumpers on the device." ::= { cfetf105Entry 16 } cfetf105CacheClean OBJECT-TYPE SYNTAX INTEGER { clean(1), dirty(2) } ACCESS read-only STATUS mandatory DESCRIPTION "When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2) Device and Management Module cache are not synchronized. The configuration currently displayed by the application has not been validated by the device. The device may need to correct the configuration, in which case the displayed configuration will change." ::= { cfetf105Entry 17 } -- ==================================================================== -- Table for a smacf100 Ethernet port. smacf100PTable OBJECT-TYPE SYNTAX SEQUENCE OF Smacf100PEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Sparse table containing one entry for each SMACF100P virtual slide-in device. This table dexcribes ONE port on a SMACFxxx colony switch" ::= { cpsSlotDetail 15 } smacf100PEntry OBJECT-TYPE SYNTAX Smacf100PEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Status and configuration entries for a single SMACF100P" INDEX { smacf100PSubDeviceIndex, smacf100PBiaIndex, smacf100PSlotIndex } ::= { smacf100PTable 1 } Smacf100PEntry ::= SEQUENCE { smacf100PSubDeviceIndex INTEGER, smacf100PBiaIndex INTEGER, smacf100PSlotIndex INTEGER, smacf100PGroups DisplayString, smacf100PCfgMatch INTEGER, smacf100PConnA INTEGER, smacf100PLink INTEGER, smacf100P100Mbps INTEGER, smacf100PFullDuplex INTEGER, smacf100PSACStat INTEGER, smacf100PEnabled INTEGER, smacf100PAutoNegot INTEGER, smacf100PAdv10HDX INTEGER, smacf100PAdv10FDX INTEGER, smacf100PAdv100HDX INTEGER, smacf100PAdv100FDX INTEGER, smacf100PSTPState INTEGER, smacf100PLastMAC MacAddress, smacf100PFarEndFaultCfg INTEGER, smacf100PFarEndFaultStat INTEGER, smacf100PTxOctets INTEGER, smacf100PWrapTxOctets INTEGER, smacf100PRxOctets INTEGER, smacf100PWrapRxOctets INTEGER, smacf100PSACCfg INTEGER, smacf100PBlockMgmt INTEGER, smacf100PBlockPort INTEGER, smacf100PTxDropPkts INTEGER, smacf100PTxBroadcastPkts INTEGER, smacf100PTxMulticastPkts INTEGER, smacf100PTxUnicastPkts INTEGER, smacf100PTxCollisions INTEGER, smacf100PTxSingleCollision INTEGER, smacf100PTxMultipleCollision INTEGER, smacf100PTxDeferredTransmit INTEGER, smacf100PTxLateCollision INTEGER, smacf100PTxExcessiveCollision INTEGER, smacf100PTxFrameInDisc INTEGER, smacf100PTxPausePkts INTEGER, smacf100PRxUndersizePkts INTEGER, smacf100PRxPausePkts INTEGER, smacf100PPkts64Octets INTEGER, smacf100PPkts65to127Octets INTEGER, smacf100PPkts128to255Octets INTEGER, smacf100PPkts256to511Octets INTEGER, smacf100PPkts512to1023Octets INTEGER, smacf100PPkts1024to1522Octets INTEGER, smacf100PRxOversizePkts INTEGER, smacf100PRxJabbers INTEGER, smacf100PRxAlignmentErrors INTEGER, smacf100PRxFCSErrors INTEGER, smacf100PRxGoodOctets INTEGER, smacf100PWrapRxGoodOctets INTEGER, smacf100PRxDropPkts INTEGER, smacf100PRxUnicastPkts INTEGER, smacf100PRxMulticastPkts INTEGER, smacf100PRxBroadcastPkts INTEGER, smacf100PRxSAChanges INTEGER, smacf100PRxFragments INTEGER, smacf100PRxExcessSizeDisc INTEGER, smacf100PRxSymbolError INTEGER, smacf100PQosPriority INTEGER, smacf100PQosPause INTEGER, smacf100PAdvPause INTEGER, smacf100PCacheClean INTEGER } smacf100PSubDeviceIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Generally, individual devices in this MIB are distinguished by BiaIndex and SlotIndex. This device differs from many in that it contains multiple subdevices. The number of subdevices varies with the manufactured configuration. Subdevices within devices are indexed by BiaIndex, SlotIndex, and SubDeviceIndex. When the subdevice column is read from the table, the value '1' is always returned." ::= { smacf100PEntry 1 } smacf100PBiaIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number (BIA) of the cabinet in which the device is installed" ::= { smacf100PEntry 2 } smacf100PSlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The slot in which the device is installed" ::= { smacf100PEntry 3 } smacf100PGroups OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent can be instructed to apply configuration changes simultaneously to all group members rather than to individual devices. Every Groups string has three automatically defined implied values: 1) The model family of the device, e.g. 'SMACF100' 2) The serial number of the cabinet in which the device is installed, in decimal with no leading zeroes, e.g. '12345', and 3) same as 2, with the slot in which the device is installed appended, enclosed in square brackets. e.g. '12345[9]'" ::= { smacf100PEntry 4 } smacf100PCfgMatch OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notApplicable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) indicates that cpsGroupCtrl.0 is null and therefore no comparison was performed." ::= { smacf100PEntry 5 } smacf100PConnA OBJECT-TYPE SYNTAX CpsConnector ACCESS read-only STATUS mandatory DESCRIPTION "The style of Fiber or Copper connector built into this device" ::= { smacf100PEntry 6 } smacf100PLink OBJECT-TYPE SYNTAX INTEGER { linkUp(1), linkDown(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of Port Link for this device" ::= { smacf100PEntry 7 } smacf100P100Mbps OBJECT-TYPE SYNTAX INTEGER { mbps100(1), mbps10(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Communication speed for this port." ::= { smacf100PEntry 8 } smacf100PFullDuplex OBJECT-TYPE SYNTAX INTEGER { fullDuplex(1), halfDuplex(2), negotiating(3) } ACCESS read-write STATUS mandatory DESCRIPTION "In most cases this is a configuration setting that controls the duplex mode; fullDuplex is full duplex and halfDuplex is half duplex. On twisted pair ports with autonegotiation enabled, this is a status indication showing the duplex value decided upon during the negotiation. When link is down, autonegotiation has not been completed yet, and the duplex setting is therefore unknown and the value is negotiating(3)." ::= { smacf100PEntry 9 } smacf100PSACStat OBJECT-TYPE SYNTAX INTEGER { changed(1), same(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This status value indicates whether or not the source MAC address attached to this port changed in the last polling period. This value tends to change quite quickly; therefore, the 'ERROR' traps that are sent when SAC is detected are a much more reliable indicator." ::= { smacf100PEntry 10 } smacf100PEnabled OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Status of of this Port. A value of yes(1) indicates this port is 'enabled'. A value of no(2) indicates this port is 'disabled'." ::= { smacf100PEntry 11 } smacf100PAutoNegot OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notSupported(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Enables or disables autonegtiation of link speed and duplex for twisted pair ports. Not supported on Fiber ports." ::= { smacf100PEntry 12 } smacf100PAdv10HDX OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notSupported(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This configuration setting controls whether or not each port advertises willingness to connect at 10Mbps, half duplex. This setting is not supported on fiber ports, and is ignored when autonegotiation is disabled." ::= { smacf100PEntry 13 } smacf100PAdv10FDX OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notSupported(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This configuration setting controls whether or not each port advertises willingness to connect at 10Mbps, full duplex. This setting is not supported on fiber ports, and is ignored when autonegotiation is disabled." ::= { smacf100PEntry 14 } smacf100PAdv100HDX OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notSupported(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This configuration setting controls whether or not each port advertises willingness to connect at 100Mbps, half duplex. This setting is not supported on fiber ports, and is ignored when autonegotiation is disabled." ::= { smacf100PEntry 15 } smacf100PAdv100FDX OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notSupported(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This configuration setting controls whether or not each port advertises willingness to connect at 100Mbps, full duplex. This setting is not supported on fiber ports, and is ignored when autonegotiation is disabled." ::= { smacf100PEntry 16 } smacf100PSTPState OBJECT-TYPE SYNTAX INTEGER { notSupported(1), disabled(2), blocking(3), listening(4), learning(5), forwarding(6) } ACCESS read-write STATUS mandatory DESCRIPTION "Port spanning tree state." ::= { smacf100PEntry 17 } smacf100PLastMAC OBJECT-TYPE SYNTAX MacAddress ACCESS read-only STATUS mandatory DESCRIPTION "Last MAC Address this port communicated with." ::= { smacf100PEntry 18 } smacf100PFarEndFaultCfg OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notSupported(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Far end fault configuration of this Port." ::= { smacf100PEntry 19 } smacf100PFarEndFaultStat OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notSupported(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Far end fault status of this port." ::= { smacf100PEntry 20 } smacf100PTxOctets OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of bytes of data transmitted through this interface." ::= { smacf100PEntry 21 } smacf100PWrapTxOctets OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of times that the unsigned 32-bit smacf100PTxOctets(21) MIB variable has wrapped." ::= { smacf100PEntry 22 } smacf100PRxOctets OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of bytes of data received through this interface." ::= { smacf100PEntry 23 } smacf100PWrapRxOctets OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of times that the unsigned 32-bit smacf100PRxOctets(23) MIB variable has wrapped." ::= { smacf100PEntry 24 } smacf100PSACCfg OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Source Address Change detection configuration. Enables or Disables the generation of traps related to source address change for this port. When disabled, the smacf100PSACStat(10) variable always reads no." ::= { smacf100PEntry 25 } smacf100PBlockMgmt OBJECT-TYPE SYNTAX INTEGER { block(1), pass(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Through this variable and others, the SMACF100 supports port- based VLANs. The SMACF100 will pass tags for IEEE 802.3ac VLANs, but will neither insert nor strip them. When this variable is set to block(1), this port may neither transmit packets to nor receive packets from management entities within this switch, i.e. the reporting unit (present in every SMACF100) and the management module (present in SMACF100 Main Management Units). This feature is intended to block traffic between particular Ethernet interfaces inside a single switch; it cannot identify or block management traffic from external sources. A single port is selected for configuration via the slot index. The subdevice index for this variable must always be 1. The logical soundness of VLAN rules cannot be validated. If you set smacf100PBlockMgmt(26) to block(1) on a port that provides a path between a reporting unit and its management module, or between a management module and its Network Management Station, you will be unable to manage the SMACF100 until the situation is rectified (by recabling to work around the misconfiguration, or by resetting the SMACF100 to factory defaults via the serial port)." ::= { smacf100PEntry 26 } smacf100PBlockPort OBJECT-TYPE SYNTAX INTEGER { block(1), pass(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Through this variable and others, the SMACF100 supports port- based VLANs. The SMACF100 will pass tags for IEEE 802.3ac VLANs, but will neither insert nor strip them. This table allows the network administrator to block traffic between pairs of ports within a single SMACF100. A pair of ports is selected for configuration by specifying a slot index and a subdevice index. The order in which the two ports are specified is unimportant, the effects of the configuration are identical on both ports. Each port has a smacf100PBlockPort(27) entry for every other port. So, communication between ports and in cabinet serial can be blocked by setting either smacf100PBlockPort... or smacf100PBlockPort... to block(1). Attempts to prevent a port from communicating with itself are ignored. Beyond that, the logical soundness of VLAN rules cannot be validated. There is one entry per subdevice, and one subdevice per port on the SMACF100." ::= { smacf100PEntry 27 } smacf100PTxDropPkts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented every time a transmit packet is dropped due to lack of resources (e.g. transmit FIFO underflow), or an internal MAC sublayer transmit error occurs that is not counted by either TxLateCollision or TxExcessiveCollision counters." ::= { smacf100PEntry 28 } smacf100PTxBroadcastPkts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of good packets transmitted by this port that are directed to a broadcast address. This counter includes neither errored broadcast packets nor valid multicast packets." ::= { smacf100PEntry 29 } smacf100PTxMulticastPkts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of good packets transmitted by this port that are directed to a multicast address. This counter includes neither errored multicast packets nor valid broadcast packets." ::= { smacf100PEntry 30 } smacf100PTxUnicastPkts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of good packets transmitted by this port that are directed to a unicast address." ::= { smacf100PEntry 31 } smacf100PTxCollisions OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of collisions experienced by this port during packet transmissions." ::= { smacf100PEntry 32 } smacf100PTxSingleCollision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets successfully transmitted by this port that experienced exactly one collision." ::= { smacf100PEntry 33 } smacf100PTxMultipleCollision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets successfully transmitted by this port that experienced more than one collision." ::= { smacf100PEntry 34 } smacf100PTxDeferredTransmit OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets transmitted by a this port for which the first transmission attempt was delayed because the medium was busy." ::= { smacf100PEntry 35 } smacf100PTxLateCollision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of times that a collision was detected later than 512 bit-times into the transmission of a packet." ::= { smacf100PEntry 36 } smacf100PTxExcessiveCollision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets that were not transmitted from this port because 16 unsucessful attempts were made to transmit the packet." ::= { smacf100PEntry 37 } smacf100PTxFrameInDisc OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of valid packets received which are discarded by the forwarding process due to lack of space on an output queue. This attribute only increments if a network device is not acting in compliance with a flow control request." ::= { smacf100PEntry 38 } smacf100PTxPausePkts OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The number of PAUSE frames transmitted by this port. This implies that the port is in full duplex mode and that 802.3x flow control was enabled at the completion of autonegotiation." ::= { smacf100PEntry 39 } smacf100PRxUndersizePkts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of good packets received by this port that are less than 64 bytes long (excluding framing bits but including the Frame Check Sequence)." ::= { smacf100PEntry 40 } smacf100PRxPausePkts OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The number of PAUSE frames recieved by this port. The PAUSE frame must have a valid MAC Control Frame EtherType field (88- 08h), have a destination MAC address of either the MAC Control frame reseved multicast address (01:80:C2:00:00:01), be a minimum of 64 bytes long (excluding preamble but including Frame Check Sequence), and have a valid CRC. Although an 802.3 compliant MAC is only permitted to transmit PAUSE frames when in full duplex mode with flow control enabled and with the transfer of PAUSE frames determined by the result of autonegotiation, an 802.3 MAC receiver is required to count all received PAUSE frames, regardless of its half/full-duplex status. An indication that a MAC is in half-duplex mode with this counter incrementing indicates a non- compliant transmitting device on the network." ::= { smacf100PEntry 41 } smacf100PPkts64Octets OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets, including error packets, that are 64 bytes long." ::= { smacf100PEntry 42 } smacf100PPkts65to127Octets OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets, including error packets, that are between 65 and 127 bytes long." ::= { smacf100PEntry 43 } smacf100PPkts128to255Octets OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets, including error packets, that are between 128 and 255 bytes long." ::= { smacf100PEntry 44 } smacf100PPkts256to511Octets OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets, including error packets, that are between 256 and 511 bytes long." ::= { smacf100PEntry 45 } smacf100PPkts512to1023Octets OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets, including error packets, that are between 512 and 1023 bytes long." ::= { smacf100PEntry 46 } smacf100PPkts1024to1522Octets OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets, including error packets, that are between 1024 and 1522 bytes long." ::= { smacf100PEntry 47 } smacf100PRxOversizePkts OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The number of good packets received by this port that are longer than 1522 bytes inclusive (excluding framing bits but including the Frame Check Sequence). Note that this counter alone will be incremented for packets in the range 1523 to 1536 bytes inclusive, whereas both this counter and the RxExcessSizeDisc counter will be incremented for packets of 1537 bytes and longer." ::= { smacf100PEntry 48 } smacf100PRxJabbers OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets received by a port that are longer than 1522 bytes and have either a Frame Check Sequence error or an alignment error." ::= { smacf100PEntry 49 } smacf100PRxAlignmentErrors OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets received by this port that have a length (excluding framing bits but including the Frame Check Sequence) between 64 and 1522 bytes inclusive, and have a bad Frame Check Sequence with a non-integral number of bytes." ::= { smacf100PEntry 50 } smacf100PRxFCSErrors OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets received by this port that have a length (excluding framing bits but including the Frame Check Sequence) between 64 and 1522 bytes inclusive, and have a bad Frame Check Sequence with a integral number of bytes." ::= { smacf100PEntry 51 } smacf100PRxGoodOctets OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of bytes in all good packets received by a port (excluding framing bits but including Frame Check Sequences)." ::= { smacf100PEntry 52 } smacf100PWrapRxGoodOctets OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of times that the unsigned 32-bit smacf100PRxGoodOctets(52) MIB variable for this port has wrapped." ::= { smacf100PEntry 53 } smacf100PRxDropPkts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of good packets received by this port that were dropped due to lack of resources (e.g. lack of input buffers) or were dropped due to a lack of resources before a determination of the validity of the packet could be made (e.g. receive FIFO overflow). The counter is only incremented if the receive error was not counted by either the RxExcessSizeDisc, the RxAlignmentErrors or the RxFCSErrors counters.)" ::= { smacf100PEntry 54 } smacf100PRxUnicastPkts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of good packets received by this port that are addressed to a unicast address." ::= { smacf100PEntry 55 } smacf100PRxMulticastPkts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of good packets received by this port that are directed to a multicast address. This counter includes neither errored multicast packets nor valid broadcast packets." ::= { smacf100PEntry 56 } smacf100PRxBroadcastPkts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of good packets received by this port that are directed to the broadcast address. This counter includes neither errored broadcast packets nor valid multicast packets." ::= { smacf100PEntry 57 } smacf100PRxSAChanges OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of times the Source Ethernet Address of good receive packets has changed from the previous value. A count greater than one generally indicates that the port is connected to a repeater-based network." ::= { smacf100PEntry 58 } smacf100PRxFragments OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets received by a port that are shorter than 64 bytes (excluding framing bits) and have either an Frame Check Sequence error or an alignment error." ::= { smacf100PEntry 59 } smacf100PRxExcessSizeDisc OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of good packets received by this port that are longer than 1536 bytes (excluding framing bits but including Frame Check Sequences) and were discarded due to excessive length. Note that the RxOversizePkts counter alone is incremented for packets in the range 1523-1536 bytes inclusive, whereas both RxExcessSizeDisc and RxOversizePkts are incremented for packets of 1537 bytes and longer." ::= { smacf100PEntry 60 } smacf100PRxSymbolError OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of times this port received a packet which had a valid length, but contained at least one invalid symbol. The counter only increments once per carrier event, and does not increment if a collision is detected during the carrier event." ::= { smacf100PEntry 61 } smacf100PQosPriority OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "When this variable is set to 'high(1)', this port becomes a high-priority port. This means that all packets received on this port for transission on other ports and all packets received on other ports for transmission on this port are placed in the high-priority queues. When the variable is set to 'default(2)', the low priority queue is used unless other conditions (i.e. an 802.1p tag or a high-priority setting for another port) prompt the use of the high priority queue." ::= { smacf100PEntry 62 } smacf100PQosPause OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "When the global variable smacf100QosEnable(7) is set to 'enabled(1)', then the port-specific variable smacf100PQosPause(63) controls whether or not the port supports half-duplex back pressure and full-duplex flow control. Otherwise, only dropping of frames is supported for the port." ::= { smacf100PEntry 63 } smacf100PAdvPause OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Enable/disable control for this advertised autonegotiation mode. When Pause capability is autonegotiated (at the Physical level), the MAC layer may then send Pause packets to pace data coming across the link. smacf100PAutoNegot(12) must be set to 'enabled(1)'. The results of this autonegotiation are ignored if smacf100QosEnable(7) is set to 'enabled(1)' and smacf100PQosPause(63) is set to 'disabled(2)'. In this case, no 'Pause' capability is supported." ::= { smacf100PEntry 64 } smacf100PCacheClean OBJECT-TYPE SYNTAX INTEGER { clean(1), dirty(2) } ACCESS read-only STATUS mandatory DESCRIPTION "When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2) Device and Management Module cache are not synchronized. The configuration currently displayed by the application has not been validated by the device. The device may need to correct the configuration, in which case the displayed configuration will change." ::= { smacf100PEntry 65 } -- =================================================================== -- Table for a CPSLD100 Slide-in LED card cpsld100Table OBJECT-TYPE SYNTAX SEQUENCE OF Cpsld100Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Sparse table containing one entry for each CPSLD100 in the stack, indexed by cabinet serial number and slot." ::= { cpsSlotDetail 16 } cpsld100Entry OBJECT-TYPE SYNTAX Cpsld100Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Status and configuration entries for a single CPSLD100" INDEX { cpsld100BiaIndex, cpsld100SlotIndex } ::= { cpsld100Table 1 } Cpsld100Entry ::= SEQUENCE { cpsld100BiaIndex INTEGER, cpsld100SlotIndex INTEGER, cpsld100SerialNumber INTEGER, cpsld100MRevision INTEGER, cpsld100Ps1Power INTEGER, cpsld100Ps1InUse INTEGER, cpsld100Ps2Power INTEGER, cpsld100Ps2InUse INTEGER } cpsld100BiaIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number (BIA) of the cabinet in which the device is installed" ::= { cpsld100Entry 1 } cpsld100SlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The slot in which the device is installed" ::= { cpsld100Entry 2 } cpsld100SerialNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number of this device" ::= { cpsld100Entry 3 } cpsld100MRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The marketing revision of this device" ::= { cpsld100Entry 4 } cpsld100Ps1Power OBJECT-TYPE SYNTAX INTEGER { on(1), off(2), notInstalled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Power status, first power supply slot. Value is on(1) when the supply is capable of supplying power." ::= { cpsld100Entry 5 } cpsld100Ps1InUse OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notInstalled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Power status, first power supply slot. Value is yes(1) when the power is selected to supply power to the cabinet." ::= { cpsld100Entry 6 } cpsld100Ps2Power OBJECT-TYPE SYNTAX INTEGER { on(1), off(2), notInstalled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Power status, second power supply slot. Value is on(1) when the supply is capable of supplying power." ::= { cpsld100Entry 7 } cpsld100Ps2InUse OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notInstalled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Power status, second power supply slot. Value is yes(1) when the power is selected to supply power to the cabinet." ::= { cpsld100Entry 8 } -- ================================================================== -- Table for a cdftf100 slide in device cdftf100Table OBJECT-TYPE SYNTAX SEQUENCE OF Cdftf100Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Sparse table containing one entry for each CDFTF100 Dual telco Media Converter in the stack, indexed by cabinet serial number and slot." ::= { cpsSlotDetail 17 } cdftf100Entry OBJECT-TYPE SYNTAX Cdftf100Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Status and configuration entries for a single CDFTF100" INDEX { cdftf100SubDeviceIndex, cdftf100BiaIndex, cdftf100SlotIndex } ::= { cdftf100Table 1 } Cdftf100Entry ::= SEQUENCE { cdftf100SubDeviceIndex INTEGER, cdftf100BiaIndex INTEGER, cdftf100SlotIndex INTEGER, cdftf100Groups DisplayString, cdftf100CfgMatch INTEGER, cdftf100SerialNumber INTEGER, cdftf100MRevision INTEGER, cdftf100TPLinkTbl INTEGER, cdftf100FiberLinkTbl INTEGER, cdftf100TPActivityTbl INTEGER, cdftf100FiberActivityTbl INTEGER, cdftf100ConnectorTbl INTEGER, cdftf100FirmwareRevision INTEGER, cdftf100CacheClean INTEGER } cdftf100SubDeviceIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Generally, individual devices in this MIB are distinguished by BiaIndex and SlotIndex. This device differs from many in that it contains multiple subdevices (in this case, switch ports). The number of subdevices varies with the manufactured configuration. Subdevices within devices are indexed by BiaIndex, SlotIndex, and SubDeviceIndex. When the subdevice column is read from the table, the value '1' is always returned." ::= { cdftf100Entry 1 } cdftf100BiaIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number (BIA) of the cabinet in which the device is installed" ::= { cdftf100Entry 2 } cdftf100SlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The slot in which the device is installed" ::= { cdftf100Entry 3 } cdftf100Groups OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent can be instructed to apply configuration changes simultaneously to all group members rather than to individual devices. Every Groups string has three automatically defined implied values: 1) The model family of the device, e.g. 'CDFTF100' 2) The serial number of the cabinet in which the device is installed, in decimal with no leading zeroes, e.g. '12345', and 3) same as 2, with the slot in which the device is installed appended, enclosed in square brackets. e.g. '12345[9]'" ::= { cdftf100Entry 4 } cdftf100CfgMatch OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notApplicable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) indicates that cpsGroupCtrl.0 is null and therefore no comparison was performed." ::= { cdftf100Entry 5 } cdftf100SerialNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number of this device" ::= { cdftf100Entry 6 } cdftf100MRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The marketing revision of the device" ::= { cdftf100Entry 7 } cdftf100TPLinkTbl OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This table contains the link status of each twisted pair port in the CDFTF100. There are multiple subdevices in this table, numbering one entry per port." ::= { cdftf100Entry 8 } cdftf100FiberLinkTbl OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This table contains the link status of each fiber port in the CDFTF100. There are multiple subdevices in this table, numbering one entry per port." ::= { cdftf100Entry 9 } cdftf100TPActivityTbl OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Netowrk traffic indicator for the copper port(s) on this device. There are multiple subdevices in this table, numbering one entry per port." ::= { cdftf100Entry 10 } cdftf100FiberActivityTbl OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Netowrk traffic indicator for the fiber port(s) on this device. There are multiple subdevices in this table, numbering one entry per port." ::= { cdftf100Entry 11 } cdftf100ConnectorTbl OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This table contains the link status of each port of this device. There are multiple subdevices in this table, numbering one entry per port." ::= { cdftf100Entry 12 } cdftf100FirmwareRevision OBJECT-TYPE SYNTAX CpsConnector ACCESS read-only STATUS mandatory DESCRIPTION "The style of connectors built into each port of this device." ::= { cdftf100Entry 13 } cdftf100CacheClean OBJECT-TYPE SYNTAX INTEGER { clean(1), dirty(2) } ACCESS read-only STATUS mandatory DESCRIPTION "When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2) Device and Management Module cache are not synchronized. The configuration currently displayed by the application has not been validated by the device. The device may need to correct the configuration, in which case the displayed configuration will change." ::= { cdftf100Entry 14 } --===================================================================== -- Table for the cpsvt100 cpsvt100Table OBJECT-TYPE SYNTAX SEQUENCE OF Cpsvt100Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Sparse table containing one entry for each CPSVT100 in the stack, indexed by cabinet serial number and slot." ::= { cpsSlotDetail 18 } cpsvt100Entry OBJECT-TYPE SYNTAX Cpsvt100Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Status and configuration entries for a single CPSVT100" INDEX { cpsvt100BiaIndex, cpsvt100SlotIndex } ::= { cpsvt100Table 1 } Cpsvt100Entry ::= SEQUENCE { cpsvt100BiaIndex INTEGER, cpsvt100SlotIndex INTEGER, cpsvt100Groups DisplayString, cpsvt100MRevision INTEGER, cpsvt100CfgMatch INTEGER, cpsvt100SerialNumber INTEGER, cpsvt100FiberLink INTEGER, cpsvt100CopperLink INTEGER, cpsvt100Fault INTEGER, cpsvt100ConnA INTEGER, cpsvt100ConnB INTEGER, cpsvt100TermTiming INTEGER, cpsvt100LoopBack INTEGER, cpsvt100CableMode INTEGER, cpsvt100DCE INTEGER, cpsvt100InvertTX INTEGER, cpsvt100InvertRX INTEGER, cpsvt100ConfigMode INTEGER, cpsvt100FirmwareRev INTEGER, cpsvt100RmtDetected INTEGER, cpsvt100RmtTermTiming INTEGER, cpsvt100RmtLoopBack INTEGER, cpsvt100RmtCableMode INTEGER, cpsvt100RmtDCE INTEGER, cpsvt100RmtInvertTX INTEGER, cpsvt100RmtInvertRX INTEGER, cpsvt100RmtConfigMode INTEGER, cpsvt100RmtFirmwareRev INTEGER, cpsvt100RmtCopperLink INTEGER, cpsvt100RmtFiberLink INTEGER, cpsvt100CacheClean INTEGER } cpsvt100BiaIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number (BIA) of the cabinet in which the device is installed" ::= { cpsvt100Entry 1 } cpsvt100SlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The slot in which the device is installed" ::= { cpsvt100Entry 2 } cpsvt100Groups OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent can be instructed to apply configuration changes simultaneously to all group members rather than to individual devices. Every Groups string has three automatically defined implied values: 1) The model family of the device, e.g. 'CPSVT100' 2) The serial number of the cabinet in which the device is installed, in decimal with no leading zeroes, e.g. '12345', and 3) same as 2, with the slot in which the device is installed appended, enclosed in square brackets. e.g. '12345[9]'" ::= { cpsvt100Entry 3 } cpsvt100MRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The marketing revision of this device" ::= { cpsvt100Entry 4 } cpsvt100CfgMatch OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), inactive(3) } ACCESS read-only STATUS mandatory DESCRIPTION "yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) indicates that cpsGroupCtrl.0 is null and therefore no comparison was performed." ::= { cpsvt100Entry 5 } cpsvt100SerialNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number of this device" ::= { cpsvt100Entry 6 } cpsvt100FiberLink OBJECT-TYPE SYNTAX INTEGER { linkUp(1), linkDown(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of Fiber Link for this device" ::= { cpsvt100Entry 7 } cpsvt100CopperLink OBJECT-TYPE SYNTAX INTEGER { linkUp(1), linkDown(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of Copper Link for this device" ::= { cpsvt100Entry 8 } cpsvt100Fault OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Value is yes(1) when either CopperLink or FiberLink has value linkDown(2)" ::= { cpsvt100Entry 9 } cpsvt100ConnA OBJECT-TYPE SYNTAX CpsConnector ACCESS read-only STATUS mandatory DESCRIPTION "The style of Fiber connector built into this device" ::= { cpsvt100Entry 10 } cpsvt100ConnB OBJECT-TYPE SYNTAX CpsConnector ACCESS read-only STATUS mandatory DESCRIPTION "The style of Copper connector built into this device" ::= { cpsvt100Entry 11 } cpsvt100TermTiming OBJECT-TYPE SYNTAX INTEGER { rxc(1), kbps56(2), kbps64(3), kbps112(4), kbps128(5), kbps256(6), kbps384(7), kbps512(8), kbps768(9), kbps1024(10), kbps1554(11), kbps2048(12), kbps3072(13), kbps4096(14), kbps6144(15), asynchronous(16) } ACCESS read-write STATUS mandatory DESCRIPTION "Local Terminal Timing setting. Terminal timing is a signal sent from a DCE to a DTE to control the rate of data the DTE sends to the DCE. Since this signal cannot be sent across the fiber after media converters are introduced, the converter must generate this signal and supply it to the DTE. The converter gets the setting from a thumbwheel. For converters attached to DTEs, the thumbwheel setting influences the transmit data rate. If the Terminal Timing setting is RXC, the DTE derives its transmit clock from the receive clock supplied by the DCE. For converters attached to DCEs, the thumbwheel setting has no effect. If two DTEs are connected via media converters, the thumbwheel settings must not be RXC." ::= { cpsvt100Entry 12 } cpsvt100LoopBack OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Remote fiber and copper loopback setting. Loopback is a testing aid available on several different products. When Loopback is enabled on an interface, all data that is sent to the interface is reflected back to the sender, and the actual condition (or even existence) of the equipment on the opposite interface is ignored." ::= { cpsvt100Entry 13 } cpsvt100CableMode OBJECT-TYPE SYNTAX INTEGER { notValid(1), rs-530A(2), rs-530(3), x-21(4), v-35(5), rs-449(6), rs-232(7), disconnected(8) } ACCESS read-only STATUS mandatory DESCRIPTION "A description of the type of cable that is attached to the Copper interface of the local device." ::= { cpsvt100Entry 14 } cpsvt100DCE OBJECT-TYPE SYNTAX INTEGER { dce(1), dte(2) } ACCESS read-only STATUS mandatory DESCRIPTION "An indication of whether this device is attached to a DCE (a computer) or a DTE (a terminal). Like cpsvt100CableMode(14), this status is derived from the type of cable that is attached to the copper interface." ::= { cpsvt100Entry 15 } cpsvt100InvertTX OBJECT-TYPE SYNTAX INTEGER { rising(1), falling(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Local transmit clock usage. Some types of high-speed serial equipment read the data signal on the rising edge of the clock, and others on the falling edge of the clock. The CPSVT100-xxx High Speed Serial converter is compatible with both types of equipment. The expectations of the equipment attached to the copper interface can be matched via jumper settings on the converter. The cpsvt100InvertTX(16) and cpsvt100InvertRX(17) status variables indicate the status of these jumpers. Most high-speed serial equipment uses the rising edge of the clock." ::= { cpsvt100Entry 16 } cpsvt100InvertRX OBJECT-TYPE SYNTAX INTEGER { rising(1), falling(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Local receive clock usage. Some types of high-speed serial equipment read the data signal on the rising edge of the clock, and others on the falling edge of the clock. The CPSVT100-xxx High Speed Serial converter is compatible with both types of equipment. The expectations of the equipment attached to the copper interface can be matched via jumper settings on the converter. The cpsvt100InvertTX(16) and cpsvt100InvertRX(17) status variables indicate the status of these jumpers. Most high-speed serial equipment uses the rising edge of the clock." ::= { cpsvt100Entry 17 } cpsvt100ConfigMode OBJECT-TYPE SYNTAX INTEGER { software(1), hardware(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all configuration control comes from physical switches or jumpers on the device." ::= { cpsvt100Entry 18 } cpsvt100FirmwareRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Local firmware revision." ::= { cpsvt100Entry 19 } cpsvt100RmtDetected OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Has the value yes(1) if management communcations have been established with a remote media converter." ::= { cpsvt100Entry 20 } cpsvt100RmtTermTiming OBJECT-TYPE SYNTAX INTEGER { rxc(1), kbps56(2), kbps64(3), kbps112(4), kbps128(5), kbps256(6), kbps384(7), kbps512(8), kbps768(9), kbps1024(10), kbps1554(11), kbps2048(12), kbps3072(13), kbps4096(14), kbps6144(15), asynchronous(16) } ACCESS read-write STATUS mandatory DESCRIPTION "Local Terminal Timing setting of the remotely managed CPSVTxxx. Terminal timing is a signal sent from a DCE to a DTE to control the rate of data the DTE sends to the DCE. Since this signal cannot be sent across the fiber after media converters are introduced, the converter must generate this signal and supply it to the DTE. The converter gets the setting from a thumbwheel. For converters attached to DTEs, the thumbwheel setting influences the transmit data rate. If the Terminal Timing setting is RXC, the DTE derives its transmit clock from the receive clock supplied by the DCE. For converters attached to DCEs, the thumbwheel setting has no effect. If two DTEs are connected via media converters, the thumbwheel settings must not be RXC." ::= { cpsvt100Entry 21 } cpsvt100RmtLoopBack OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Remote fiber and copper loopback setting. Loopback is a testing aid available on several different products. When Loopback is enabled on an interface, all data that is sent to the interface is reflected back to the sender, and the actual condition (or even existence) of the equipment on the opposite interface is ignored. This variable is identical to cpsvt100LoopBack, except that it is for the remotely managed cpsvt100." ::= { cpsvt100Entry 22 } cpsvt100RmtCableMode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A description of the type of cable that is attached to the Copper interface of the local device." ::= { cpsvt100Entry 23 } cpsvt100RmtDCE OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "An indication of whether this device is attached to a DCE (a computer) or a DTE (a terminal). Like cpsvt100CableMode(14), this status is derived from the type of cable that is attached to the copper interface." ::= { cpsvt100Entry 24 } cpsvt100RmtInvertTX OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Local transmit clock usage. Some types of high-speed serial equipment read the data signal on the rising edge of the clock, and others on the falling edge of the clock. The CPSVT100-xxx High Speed Serial converter is compatible with both types of equipment. The expectations of the equipment attached to the copper interface can be matched via jumper settings on the converter. The cpsvt100InvertTX(16) and cpsvt100InvertRX(17) status variables indicate the status of these jumpers. Most high-speed serial equipment uses the rising edge of the clock." ::= { cpsvt100Entry 25 } cpsvt100RmtInvertRX OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Local receive clock usage. Some types of high-speed serial equipment read the data signal on the rising edge of the clock, and others on the falling edge of the clock. The CPSVT100-xxx High Speed Serial converter is compatible with both types of equipment. The expectations of the equipment attached to the copper interface can be matched via jumper settings on the converter. The cpsvt100InvertTX(16) and cpsvt100InvertRX(17) status variables indicate the status of these jumpers. Most high-speed serial equipment uses the rising edge of the clock." ::= { cpsvt100Entry 26 } cpsvt100RmtConfigMode OBJECT-TYPE SYNTAX INTEGER { software(1), hardware(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all configuration control comes from physical switches or jumpers on the device." ::= { cpsvt100Entry 27 } cpsvt100RmtFirmwareRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Local firmware revision." ::= { cpsvt100Entry 28 } cpsvt100RmtCopperLink OBJECT-TYPE SYNTAX INTEGER { linkUp(1), linkDown(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of Copper Link for this device" ::= { cpsvt100Entry 29 } cpsvt100RmtFiberLink OBJECT-TYPE SYNTAX INTEGER { linkUp(1), linkDown(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of Fiber Link for this device" ::= { cpsvt100Entry 30 } cpsvt100CacheClean OBJECT-TYPE SYNTAX INTEGER { clean(1), dirty(2) } ACCESS read-only STATUS mandatory DESCRIPTION "When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2) Device and Management Module cache are not synchronized. The configuration currently displayed by the application has not been validated by the device. The device may need to correct the configuration, in which case the displayed configuration will change." ::= { cpsvt100Entry 31 } -- ======================================================================== -- Table for a cemtf100 slide in card. cemtf100Table OBJECT-TYPE SYNTAX SEQUENCE OF Cemtf100Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Sparse table containing one entry for each CEMTF100 in the stack, indexed by cabinet serial number and slot." ::= { cpsSlotDetail 19 } cemtf100Entry OBJECT-TYPE SYNTAX Cemtf100Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Status and configuration entries for a single CEMTF100" INDEX { cemtf100BiaIndex, cemtf100SlotIndex } ::= { cemtf100Table 1 } Cemtf100Entry ::= SEQUENCE { cemtf100BiaIndex INTEGER, cemtf100SlotIndex INTEGER, cemtf100Groups DisplayString, cemtf100MRevision INTEGER, cemtf100CfgMatch INTEGER, cemtf100SerialNumber INTEGER, cemtf100FiberLink INTEGER, cemtf100OffHook INTEGER, cemtf100Fault INTEGER, cemtf100ConnA INTEGER, cemtf100ConnB INTEGER, cemtf100CacheClean INTEGER } cemtf100BiaIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number (BIA) of the cabinet in which the device is installed" ::= { cemtf100Entry 1 } cemtf100SlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The slot in which the device is installed" ::= { cemtf100Entry 2 } cemtf100Groups OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent can be instructed to apply configuration changes simultaneously to all group members rather than to individual devices. Every Groups string has three automatically defined implied values: 1) The model family of the device, e.g. 'CEMTF100' 2) The serial number of the cabinet in which the device is installed, in decimal with no leading zeroes, e.g. '12345', and 3) same as 2, with the slot in which the device is installed appended, enclosed in square brackets. e.g. '12345[9]'" ::= { cemtf100Entry 3 } cemtf100MRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The marketing revision of this device" ::= { cemtf100Entry 4 } cemtf100CfgMatch OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notApplicable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) indicates that cpsGroupCtrl.0 is null and therefore no comparison was performed." ::= { cemtf100Entry 5 } cemtf100SerialNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number of this device" ::= { cemtf100Entry 6 } cemtf100FiberLink OBJECT-TYPE SYNTAX INTEGER { linkUp(1), linkDown(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of Fiber Link for this device" ::= { cemtf100Entry 7 } cemtf100OffHook OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of Twisted Pair Link for this device" ::= { cemtf100Entry 8 } cemtf100Fault OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Value is yes(1) when either OffHook or FiberLink has value of down" ::= { cemtf100Entry 9 } cemtf100ConnA OBJECT-TYPE SYNTAX CpsConnector ACCESS read-only STATUS mandatory DESCRIPTION "The style of Fiber connector built into this device" ::= { cemtf100Entry 10 } cemtf100ConnB OBJECT-TYPE SYNTAX CpsConnector ACCESS read-only STATUS mandatory DESCRIPTION "The style of Copper connector built into this device" ::= { cemtf100Entry 11 } cemtf100CacheClean OBJECT-TYPE SYNTAX INTEGER { clean(1), dirty(2) } ACCESS read-only STATUS mandatory DESCRIPTION "When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2) Device and Management Module cache are not synchronized. The configuration currently displayed by the application has not been validated by the device. The device may need to correct the configuration, in which case the displayed configuration will change." ::= { cemtf100Entry 12 } -- ======================================================================== -- Table for a captf100 slide in card. captf100Table OBJECT-TYPE SYNTAX SEQUENCE OF Captf100Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Sparse table containing one entry for each CAPTF100 in the stack, indexed by cabinet serial number and slot." ::= { cpsSlotDetail 20 } captf100Entry OBJECT-TYPE SYNTAX Captf100Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Status and configuration entries for a single CAPTF100" INDEX { captf100BiaIndex, captf100SlotIndex } ::= { captf100Table 1 } Captf100Entry ::= SEQUENCE { captf100BiaIndex INTEGER, captf100SlotIndex INTEGER, captf100Groups DisplayString, captf100MRevision INTEGER, captf100CfgMatch INTEGER, captf100SerialNumber INTEGER, captf100FiberLink INTEGER, captf100InUse INTEGER, captf100Fault INTEGER, captf100ConnA INTEGER, captf100ConnB INTEGER, captf100FirmwareRev INTEGER, captf100CacheClean INTEGER, captf100Emulates INTEGER } captf100BiaIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number (BIA) of the cabinet in which the device is installed" ::= { captf100Entry 1 } captf100SlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The slot in which the device is installed" ::= { captf100Entry 2 } captf100Groups OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent can be instructed to apply configuration changes simultaneously to all group members rather than to individual devices. Every Groups string has three automatically defined implied values: 1) The model family of the device, e.g. 'CAPTF100' 2) The serial number of the cabinet in which the device is installed, in decimal with no leading zeroes, e.g. '12345', and 3) same as 2, with the slot in which the device is installed appended, enclosed in square brackets. e.g. '12345[9]'" ::= { captf100Entry 3 } captf100MRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The marketing revision of this device" ::= { captf100Entry 4 } captf100CfgMatch OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notApplicable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) indicates that cpsGroupCtrl.0 is null and therefore no comparison was performed." ::= { captf100Entry 5 } captf100SerialNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number of this device" ::= { captf100Entry 6 } captf100FiberLink OBJECT-TYPE SYNTAX INTEGER { linkUp(1), linkDown(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of Fiber Link for this device" ::= { captf100Entry 7 } captf100InUse OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of Twisted Pair Link for this device" ::= { captf100Entry 8 } captf100Fault OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Value is yes(1) when either OffHook or FiberLink has value of down" ::= { captf100Entry 9 } captf100ConnA OBJECT-TYPE SYNTAX CpsConnector ACCESS read-only STATUS mandatory DESCRIPTION "The style of Fiber connector built into this device" ::= { captf100Entry 10 } captf100ConnB OBJECT-TYPE SYNTAX CpsConnector ACCESS read-only STATUS mandatory DESCRIPTION "The style of Copper connector built into this device" ::= { captf100Entry 11 } captf100FirmwareRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The firmware revision level for this device." ::= { captf100Entry 12 } captf100CacheClean OBJECT-TYPE SYNTAX INTEGER { clean(1), dirty(2) } ACCESS read-only STATUS mandatory DESCRIPTION "When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2) Device and Management Module cache are not synchronized. The configuration currently displayed by the application has not been validated by the device. The device may need to correct the configuration, in which case the displayed configuration will change." ::= { captf100Entry 13 } captf100Emulates OBJECT-TYPE SYNTAX INTEGER { phone(1), coStandard(2), coAutoRingDown(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This read-only variable indicates the emulation type and configuration of the device. CAPTF100 devices exist in two varieties, the CAPTF10033xx-100, the copper port of which emulates a telephone, and the CAPTF10033xx-110, the copper port of which emulates the Central Office (CO) (i.e. a wall jack that one would plug a telephone into). The Standard CAPTF100 configuration is employed when a fiber extension between a wall jack and a distant telephone is desired. The CAPTF100 whose copper port was plugged into the wall jack must be of the variety that emulates a telephone. The value of the captf100Emulates(14) variable of such a device will be phone(1). The CAPTF100 whose copper port was plugged into the telephone must be of the variety that emulates the CO, and that device must be jumpered for 'Standard' operation. The value of its captf100Emulates(14) variable would be coStandard(2). Alternatively, CAPTF100 converters can be used to provide a point-to-point fiber link between two telephones. This is known as the Automatic Ring-Down configuration. When one telephone goes off-hook, the other rings. When both are off hook, voice communication is possible. In this configuration, both CAPTF100 devices must be of the variety that emulates the CO, and both devices must be jumpered for 'Automatic Ring-Down' operation. The value of their captf100Emulates(14) variables would be coAutoRingDown(3)." ::= { captf100Entry 14 } -- ================================================================== -- Table for a cfetf205 slide in card. cfetf205Table OBJECT-TYPE SYNTAX SEQUENCE OF Cfetf205Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Sparse table containing one entry for each CFTEF205 100Mbps Twisted-Pair to Fiber Ethernet Media Converter in the stack, indexed by cabinet serial number and slot." ::= { cpsSlotDetail 21 } cfetf205Entry OBJECT-TYPE SYNTAX Cfetf205Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Status and configuration entries for a single CFETF205" INDEX { cfetf205BiaIndex, cfetf205SlotIndex } ::= { cfetf205Table 1 } Cfetf205Entry ::= SEQUENCE { cfetf205BiaIndex INTEGER, cfetf205SlotIndex INTEGER, cfetf205Groups DisplayString, cfetf205MRevision INTEGER, cfetf205CfgMatch INTEGER, cfetf205SerialNumber INTEGER, cfetf205ConnA INTEGER, cfetf205ConnB INTEGER, cfetf205TPLink INTEGER, cfetf205FiberLink INTEGER, cfetf205Fault INTEGER, cfetf205FastLinkPulse INTEGER, cfetf205Enabled INTEGER, cfetf205Pause INTEGER, cfetf205LinkPassThrough INTEGER, cfetf205AutoCross INTEGER, cfetf205TPActivity INTEGER, cfetf205FiberActivity INTEGER, cfetf205ConfigMode INTEGER, cfetf205FarEndFault INTEGER, cfetf205CacheClean INTEGER } cfetf205BiaIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number (BIA) of the cabinet in which the device is installed" ::= { cfetf205Entry 1 } cfetf205SlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The slot in which the device is installed" ::= { cfetf205Entry 2 } cfetf205Groups OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent can be instructed to apply configuration changes simultaneously to all group members rather than to individual devices. Every Groups string has three automatically defined implied values: 1) The model family of the device, e.g. 'CFETF205' 2) The serial number of the cabinet in which the device is installed, in decimal with no leading zeroes, e.g. '12345', and 3) same as 2, with the slot in which the device is installed appended, enclosed in square brackets. e.g. '12345[9]'" ::= { cfetf205Entry 3 } cfetf205MRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The marketing revision of this device" ::= { cfetf205Entry 4 } cfetf205CfgMatch OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notApplicable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) indicates that cpsGroupCtrl.0 is null and therefore no comparison was performed." ::= { cfetf205Entry 5 } cfetf205SerialNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number of this device" ::= { cfetf205Entry 6 } cfetf205ConnA OBJECT-TYPE SYNTAX CpsConnector ACCESS read-only STATUS mandatory DESCRIPTION "The style of Fiber connector built into this device" ::= { cfetf205Entry 7 } cfetf205ConnB OBJECT-TYPE SYNTAX CpsConnector ACCESS read-only STATUS mandatory DESCRIPTION "The style of Copper connector built into this device" ::= { cfetf205Entry 8 } cfetf205TPLink OBJECT-TYPE SYNTAX INTEGER { linkUp(1), linkDown(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of Twisted Pair Link for this device" ::= { cfetf205Entry 9 } cfetf205FiberLink OBJECT-TYPE SYNTAX INTEGER { linkUp(1), linkDown(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of Fiber Link for this device" ::= { cfetf205Entry 10 } cfetf205Fault OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Value is yes(1) when either TPLink or FiberLink has value linkDown(2)" ::= { cfetf205Entry 11 } cfetf205FastLinkPulse OBJECT-TYPE SYNTAX INTEGER { autonegotiate(1), hdx100Btx(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When set to autonegotiate(1), converter sends Fast Link Pulses on its twisted pair port, thereby participating in autonegotiation of duplex between the converter's twisted pair port and that of the connected station. If that station supports Full- Duplex (FDX) operation, FDX will be used. If not, the twisted pair will operate in Half-Duplex (HDX) mode. When set to hdx100Btx(2), the converter instead sends 100Mbps idles (rather than Fast Link Pulses) on its twisted pair port (i.e. it declines to negotiate), which forces the twisted pair to operate in HDX mode regardless of the capabilities of the connected station. When operating in HDX mode, the twisted pair can support traffic in only one direction at a time. In FDX mode, traffic can pass in both directions simultaneously, thus theoretically doubling network performance." ::= { cfetf205Entry 12 } cfetf205Enabled OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When this configuration item is set to no(2), the device passes no network traffic." ::= { cfetf205Entry 13 } cfetf205Pause OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The Pause feature allows Ethernet MACs that support it to send data pacing 'Pause' messages to each other. Support for Pause is negotiated at the physical level and passed up to the MAC. While the MAC's Pause messages themselves can pass over the fiber link that this pair of media converters introduces, the TP physical layer negotiations to enable Pause can not. Therefore, if both end station MACs support Pause and wish to use it, the Pause negotiation must be re-generated by the media converters on both ends. By setting this configuration option to enabled(1), you are indicating to the local twisted pair station that the twisted pair station on the other side of the other media converter supports Pause and wishes to use it. This variable must be set consistently on both of the paired media converters." ::= { cfetf205Entry 14 } cfetf205LinkPassThrough OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/Disable for Link Pass Through, a feature that causes loss of link on one side of a media converter to be passed through to the other side, so that upstream equipment can see the fault condition." ::= { cfetf205Entry 15 } cfetf205AutoCross OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/Disable for automatic copper TX/RX pair correction. When disabled, the port operates in MDI mode." ::= { cfetf205Entry 16 } cfetf205TPActivity OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notSupported(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Network traffic indicator for Copper side of this device" ::= { cfetf205Entry 17 } cfetf205FiberActivity OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notSupported(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Network traffic indicator for Fiber side of this device" ::= { cfetf205Entry 18 } cfetf205ConfigMode OBJECT-TYPE SYNTAX INTEGER { software(1), hardware(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all configuration control comes from physical switches or jumpers on the device." ::= { cfetf205Entry 19 } cfetf205FarEndFault OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notSupported(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Far End Fault configuration of this device. Far End Fault causes the fiber transmitter to generate a Far End Fault pattern upon the loss of a receiver signal detect. When the receiver detects signal again, the transmitter stops transmitting the Far End Fault pattern." ::= { cfetf205Entry 20 } cfetf205CacheClean OBJECT-TYPE SYNTAX INTEGER { clean(1), dirty(2) } ACCESS read-only STATUS mandatory DESCRIPTION "When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2) Device and Management Module cache are not synchronized. The configuration currently displayed by the application has not been validated by the device. The device may need to correct the configuration, in which case the displayed configuration will change." ::= { cfetf205Entry 21 } -- ================================================================ -- Table for the cbftf150 cbftf150Table OBJECT-TYPE SYNTAX SEQUENCE OF Cbftf150Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Sparse table containing one entry for each CBFTF150 switch in the stack. Indexed by sub-device index, cabinet serial number, and slot. Note that some columns of this table support multiple subdevices, and some do not. For example, there is exactly one SerialNumber for each CBFTF150. No subdevices exist, so the placeholder value 1 is used as the subdevice index. However, a CBFTF150 has multiple switch ports, which are indexed as different subdevices, starting with 1. Columns with subdevices have names ending in 'Tbl'" ::= { cpsSlotDetail 22 } cbftf150Entry OBJECT-TYPE SYNTAX Cbftf150Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Status and configuration entries for a single CBFTF150" INDEX { cbftf150SubDeviceIndex, cbftf150BiaIndex, cbftf150SlotIndex } ::= { cbftf150Table 1 } Cbftf150Entry ::= SEQUENCE { cbftf150SubDeviceIndex INTEGER, cbftf150BiaIndex INTEGER, cbftf150SlotIndex INTEGER, cbftf150Groups DisplayString, cbftf150MRevision INTEGER, cbftf150CfgMatch INTEGER, cbftf150SerialNumber INTEGER, cbftf150ConfigMode INTEGER, cbftf150FirmwareRevision INTEGER, cbftf150FormFactor INTEGER, cbftf150AutoNegotTbl INTEGER, cbftf150FullDuplexTbl INTEGER, cbftf150100MbpsTbl INTEGER, cbftf150CrossTbl INTEGER, cbftf150FarEndFaultTbl INTEGER, cbftf150ConnectorTbl INTEGER, cbftf150LinkTbl INTEGER, cbftf150PortCount INTEGER, cbftf150CacheClean INTEGER } cbftf150SubDeviceIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Generally, individual devices in this MIB are distinguished by BiaIndex and SlotIndex. This device differs from many in that it contains multiple subdevices (in this case, switch ports). The number of subdevices varies with the manufactured configuration. Subdevices within devices are indexed by BiaIndex, SlotIndex, and SubDeviceIndex. When the subdevice column is read from the table, the value '1' is always returned." ::= { cbftf150Entry 1 } cbftf150BiaIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number (BIA) of the cabinet in which the device is installed. There are no subdevices for this value, so the placeholder value 1 is always used for that index." ::= { cbftf150Entry 2 } cbftf150SlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The slot in which the device is installed. Power Supplies occupy special slots numbered 125 and higher. There are no subdevices for this value, so the placeholder value 1 is always used for that index." ::= { cbftf150Entry 3 } cbftf150Groups OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent can be instructed to apply configuration changes simultaneously to all group members rather than to individual devices. Every Groups string has three automatically defined implied values: 1) The model family of the device, e.g. 'cbftf150' 2) The serial number of the cabinet in which the device is installed, in decimal with no leading zeroes, e.g. '12345', and 3) same as 2, with the slot in which the device is installed appended, enclosed in square brackets. e.g. '12345[9]' There are no subdevices for this value, so the placeholder value 1 is always used for that index." ::= { cbftf150Entry 4 } cbftf150MRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The marketing revision of this device. There are no subdevices for this value, so the placeholder value 1 is always used for that index." ::= { cbftf150Entry 5 } cbftf150CfgMatch OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notApplicable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) indicates that cpsGroupCtrl.0 is null and therefore no comparison was performed. There are no subdevices for this value, so the placeholder value 1 is always used for that index." ::= { cbftf150Entry 6 } cbftf150SerialNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number of this device. There are no subdevices for this value, so the placeholder value 1 is always used for that index." ::= { cbftf150Entry 7 } cbftf150ConfigMode OBJECT-TYPE SYNTAX INTEGER { software(1), hardware(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This device may have a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all configuration control comes from physical switches or jumpers on the device. There are no subdevices for this value, so the placeholder value 1 is always used for that index." ::= { cbftf150Entry 8 } cbftf150FirmwareRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The firmware revision level for this device. There are no subdevices for this value, so the placeholder value 1 is always used for that index." ::= { cbftf150Entry 9 } cbftf150FormFactor OBJECT-TYPE SYNTAX INTEGER { s1W2a(1), s1W1N2a(2), s1W1N1a(3), s2W2N4a(4), s2W1N5a(5) } ACCESS read-only STATUS mandatory DESCRIPTION "A code corresponding to a physical configuration of the product. This code indicates the number of slots occupied and the number of physical connectors present. In the labels for the values above, s indicates the number of slots occupied, W is a count of Wide port positions (which can built as almost any type of connector), and N is a count of narrow port positions (which are typically twisted pair ports). The lowercase letter at the end differentiates different form factors that would otherwise have identical descriptions under this limited scheme." ::= { cbftf150Entry 10 } cbftf150AutoNegotTbl OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notSupported(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Enables or disables autonegtiation of link speed and duplex for twisted pair ports. Not supported on Fiber ports. There are multiple subdevices in this table, numbering one entry per port." ::= { cbftf150Entry 11 } cbftf150FullDuplexTbl OBJECT-TYPE SYNTAX INTEGER { fullDuplex(1), halfDuplex(2), negotiating(3) } ACCESS read-write STATUS mandatory DESCRIPTION "In most cases this is a configuration setting that controls the duplex mode; fullDuplex is full duplex and halfDuplex is half duplex. On twisted pair ports with autonegotiation enabled, this is a status indication showing the duplex value decided upon during the negotiation. When link is down, autonegotiation has not been completed yet, and the duplex setting is therefore unknown and the value is negotiating(3). There are multiple subdevices in this table, numbering one entry per port." ::= { cbftf150Entry 12 } cbftf150100MbpsTbl OBJECT-TYPE SYNTAX INTEGER { mbps100(1), mbps10(2), negotiating(3) } ACCESS read-write STATUS mandatory DESCRIPTION "In most cases this is a configuration setting that controls the link speed. On twisted pair ports with autonegotiation enabled, this is a status indication showing the link speed decided upon during negotiation. When link is down, autonegotiation has not been completed yet, and the link speed is therefore unknown and is negotiating(3). This variable is an indicator only for fiber ports; all fiber ports report mbps100(1) at all times. There are multiple subdevices in this table, numbering one entry per port." ::= { cbftf150Entry 13 } cbftf150CrossTbl OBJECT-TYPE SYNTAX INTEGER { auto(1), mdi(2), mdix(3), notSupported(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Configuration setting for copper TX/RX pair correction. A setting of auto(1) causes the port to automatically correct TX/RX pairs if necessary. If autonegotiation is disabled on the port, the auto(1) setting is not supported. A setting of mdi(2) causes the TX/RX pairs to be passed straight through with no correction. A setting of mdix(3) causes the TX/RX pairs to be swapped. This setting is supprted for copper ports only; a read-only value of notSupported(4) is returned for fiber ports. There are multiple subdevices in this table, numbering one entry per port." ::= { cbftf150Entry 14 } cbftf150FarEndFaultTbl OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notSupported(3) } ACCESS read-write STATUS mandatory DESCRIPTION "When Far End Fault is set to enabled(1), a loss of link on receive will cause the transmitter to shut down, in order to inform the device at the far end of the link that a fault has occurred. Far End Fault is only supported on fiber ports. A read-only value of notSupported(3) is returned for copper ports. There are multiple subdevices in this table, numbering one entry per port." ::= { cbftf150Entry 15 } cbftf150ConnectorTbl OBJECT-TYPE SYNTAX CpsConnector ACCESS read-only STATUS mandatory DESCRIPTION "The style of connectors built into each port of this device. There are multiple subdevices in this table, numbering one entry per port." ::= { cbftf150Entry 16 } cbftf150LinkTbl OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This table contains the link status of each port in the switch. There are multiple subdevices in this table, numbering one entry per port." ::= { cbftf150Entry 17 } cbftf150PortCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A count of the switch ports in this device. i.e. the maximum subdevice index supported by this switch." ::= { cbftf150Entry 18 } cbftf150CacheClean OBJECT-TYPE SYNTAX INTEGER { clean(1), dirty(2) } ACCESS read-only STATUS mandatory DESCRIPTION "When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2) Device and Management Module cache are not synchronized. The configuration currently displayed by the application has not been validated by the device. The device may need to correct the configuration, in which case the displayed configuration will change." ::= { cbftf150Entry 19 } -- ================================================================== -- Table for the cgfeb100 cgfeb100Table OBJECT-TYPE SYNTAX SEQUENCE OF Cgfeb100Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Sparse table containing one entry for each CGFEB100 10/100/1000 Ethernet to Fiber converter in the stack. Indexed by cabinet serial number and slot." ::= { cpsSlotDetail 23 } cgfeb100Entry OBJECT-TYPE SYNTAX Cgfeb100Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Status and configuration entries for a single CGFEB100" INDEX { cgfeb100BiaIndex, cgfeb100SlotIndex } ::= { cgfeb100Table 1 } Cgfeb100Entry ::= SEQUENCE { cgfeb100BiaIndex INTEGER, cgfeb100SlotIndex INTEGER, cgfeb100Groups DisplayString, cgfeb100MRevision INTEGER, cgfeb100CfgMatch INTEGER, cgfeb100SerialNumber INTEGER, cgfeb100ConfigMode INTEGER, cgfeb100FirmwareRevision INTEGER, cgfeb100SelfTestFailed INTEGER, cgfeb100MonitorType INTEGER, cgfeb100LinkPassThrough INTEGER, cgfeb100QosEnabled INTEGER, cgfeb100QosHPThreshold INTEGER, cgfeb100QosLqWeight INTEGER, cgfeb100QosHqWeight INTEGER, cgfeb100ConnA INTEGER, cgfeb100TPLink INTEGER, cgfeb100TPSpeedCfg INTEGER, cgfeb100TPSpeedStat INTEGER, cgfeb100TPFullDuplexCfg INTEGER, cgfeb100TPFullDuplexStat INTEGER, cgfeb100TPCrossCfg INTEGER, cgfeb100TPCrossStat INTEGER, cgfeb100TPAutoNegot INTEGER, cgfeb100TPAdv10HDX INTEGER, cgfeb100TPAdv10FDX INTEGER, cgfeb100TPAdv100HDX INTEGER, cgfeb100TPAdv100FDX INTEGER, cgfeb100TPAdv1000HDX INTEGER, cgfeb100TPAdv1000FDX INTEGER, cgfeb100TPLpAdvPause INTEGER, cgfeb100TPLpAdv10HDX INTEGER, cgfeb100TPLpAdv10FDX INTEGER, cgfeb100TPLpAdv100HDX INTEGER, cgfeb100TPLpAdv100FDX INTEGER, cgfeb100TPLpAdv1000HDX INTEGER, cgfeb100TPLpAdv1000FDX INTEGER, cgfeb100TPAdvPause INTEGER, cgfeb100TPQosPause INTEGER, cgfeb100TPSacCfg INTEGER, cgfeb100TPSacStat INTEGER, cgfeb100ConnB INTEGER, cgfeb100FiberLink INTEGER, cgfeb100FiberFullDuplexCfg INTEGER, cgfeb100FiberFullDuplexStat INTEGER, cgfeb100FiberAutoNegot INTEGER, cgfeb100FiberAdv1000HDX INTEGER, cgfeb100FiberAdv1000FDX INTEGER, cgfeb100FiberLpAdv1000HDX INTEGER, cgfeb100FiberLpAdv1000FDX INTEGER, cgfeb100FiberLpAdvPause INTEGER, cgfeb100FiberAdvPause INTEGER, cgfeb100FiberQosPause INTEGER, cgfeb100FiberSacCfg INTEGER, cgfeb100FiberSacStat INTEGER, cgfeb100MonitorTap INTEGER, cgfeb100CacheClean INTEGER } cgfeb100BiaIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number (BIA) of the cabinet in which the device is installed." ::= { cgfeb100Entry 1 } cgfeb100SlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The slot in which the device is installed. Power Supplies occupy special slots numbered 125 and higher." ::= { cgfeb100Entry 2 } cgfeb100Groups OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent can be instructed to apply configuration changes simultaneously to all group members rather than to individual devices. Every Groups string has three automatically defined implied values: 1) The model family of the device, e.g. 'cgfeb100' 2) The serial number of the cabinet in which the device is installed, in decimal with no leading zeroes, e.g. '12345', and 3) same as 2, with the slot in which the device is installed appended, enclosed in square brackets. e.g. '12345[9]'." ::= { cgfeb100Entry 3 } cgfeb100MRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The marketing revision of this device." ::= { cgfeb100Entry 4 } cgfeb100CfgMatch OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notApplicable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) indicates that cpsGroupCtrl.0 is null and therefore no comparison was performed." ::= { cgfeb100Entry 5 } cgfeb100SerialNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number of this device." ::= { cgfeb100Entry 6 } cgfeb100ConfigMode OBJECT-TYPE SYNTAX INTEGER { software(1), hardware(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This device may have a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all configuration control comes from physical switches or jumpers on the device." ::= { cgfeb100Entry 7 } cgfeb100FirmwareRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The firmware revision level for this device." ::= { cgfeb100Entry 8 } cgfeb100SelfTestFailed OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This variable indicates the status of the pass/fail power on test. If the power on test fails, normal operation of this device is probably not possible." ::= { cgfeb100Entry 9 } cgfeb100MonitorType OBJECT-TYPE SYNTAX INTEGER { fiber(1), twistedPair(2), notInstalled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Some versions of this device support the monitoring of network traffic passing through the converter's fiber interface via a dedicated monitoring port to which a capture device can be attached. There are two different versions of the monitoring capability. One has a fiber connector, and the other has a twisted pair connector. Both versions monitor the fiber port. If this variable has the value fiber(1) or twistedPair(2), this means that a monitoring port is present and that port has the specified type of interface. In this case, the device occupies two slots. If the value is notInstalled(3), there is no monitoring capability and the device occupies one slot. See also cgfeb100MonitorTap(56)." ::= { cgfeb100Entry 10 } cgfeb100LinkPassThrough OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notSupported(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This configuration item allows Link Pass Through to be enabled(1) or disabled(2). Link Passthrough causes loss of link on one side of a media converter to be passed through to the other side, so that upstream equipment can see fault conditions that would otherwise be hidden by the media converters. On some models, the Link Passthrough logic views receipt of a Far End Fault error pattern as being equivalent to loss of link. The net effect of this is that when either fiber is disconnected, link is dropped on the other side of the converter. Normally, only the disconnection of the Receive fiber would cause this reaction. " ::= { cgfeb100Entry 11 } cgfeb100QosEnabled OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notSupported(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows Quality of Service functions to be enabled or disabled. This includes the processing of 802.1p tags (See cgfeb100QosHPThreshold(13), cgfeb100QosLqWeight(14), and smacf100QosHqWeight(15)), and half-duplex back pressure and full-duplex flow control. (See cgfeb100TpQosPause(39) and cgfeb100FiberQosPause(52))." ::= { cgfeb100Entry 12 } cgfeb100QosHPThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "When an incoming 802.1p priority tag value is greater than or equal to this value (from 0 to 7), the incoming packet will be classified as high-priority. Ignored when cgfeb100QosEnable(13) is set to 'disabled(2)'." ::= { cgfeb100Entry 13 } cgfeb100QosLqWeight OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A value between 1 and 15 indicating the number of packets that should be processed from the low-priority queue before attention is turned to the high-priority queue. Ignored when cgfeb100QosEnable(13) is set to 'disabled(2)'." ::= { cgfeb100Entry 14 } cgfeb100QosHqWeight OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A value between 1 and 15 indicating the number of packets that should be processed from the high-priority queue before attention is turned to the low-priority queue. Ignored when cgfeb100QosEnable(13) is set to 'disabled(2)'." ::= { cgfeb100Entry 15 } cgfeb100ConnA OBJECT-TYPE SYNTAX CpsConnector ACCESS read-only STATUS mandatory DESCRIPTION "The style of copper connector built into this device." ::= { cgfeb100Entry 16 } cgfeb100TPLink OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Twisted Pair link status." ::= { cgfeb100Entry 17 } cgfeb100TPSpeedCfg OBJECT-TYPE SYNTAX INTEGER { mbps10(1), mbps100(2), auto(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The desired speed of the Twisted Pair interface. This speed can be set to 10Mbps(1) or 100Mbps(2). Operation at 1000Mbps requires autonegotiation. When cgfeb100TpAutonegot(24) has the value enabled(1) or cgfeb100ConfigMode(7) has the value hardware(2), this variable has the read-only value auto(3)." ::= { cgfeb100Entry 18 } cgfeb100TPSpeedStat OBJECT-TYPE SYNTAX INTEGER { mbps10(1), mbps100(2), mbps1000(3), notApplicable(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The actual speed of the Twisted Pair interface: 10Mbps(1), 100Mbps(2), or 1000Mbps(3). If cgfeb100TpAutonegot(24) has the value enabled(1) and cgfeb100TpLink(17) has the value down(2), this variable has the value notApplicable(4)." ::= { cgfeb100Entry 19 } cgfeb100TPFullDuplexCfg OBJECT-TYPE SYNTAX INTEGER { fdx(1), hdx(2), auto(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The desired duplex setting of the Twisted Pair interface. This can be set to fdx(1) (full duplex) or hdx(2) (half duplex). When cgfeb100TpAutonegot(24) has the value enabled(1) or cgfeb100ConfigMode(7) has the value hardware(2), this variable has the read-only value auto(3)." ::= { cgfeb100Entry 20 } cgfeb100TPFullDuplexStat OBJECT-TYPE SYNTAX INTEGER { fdx(1), hdx(2), notApplicable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The actual duplex behavior of the Twisted Pair interface. If cgfeb100TpAutonegot(24) has the value enabled(1) and cgfeb100TpLink(17) has the value down(2), this variable has the value notApplicable(4)." ::= { cgfeb100Entry 21 } cgfeb100TPCrossCfg OBJECT-TYPE SYNTAX INTEGER { mdi(1), mdix(2), auto(3), notApplicable(4) } ACCESS read-write STATUS mandatory DESCRIPTION "The desired TX/RX Pair orientation of the Twisted Pair interface. This can be set to mdi(1) (straight through), mdix(2) (crossed over), or auto(3). When cgfeb100ConfigMode(7) has the value hardware(2), this variable has the read-only value notApplicable(4)." ::= { cgfeb100Entry 22 } cgfeb100TPCrossStat OBJECT-TYPE SYNTAX INTEGER { mdi(1), mdix(2), auto(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The actual TX/RX Pair orientation of the Twisted Pair interface, usually mdi(1) (straight through) or mdix(2) (crossed over). When the device does not know the pair orientation, this variable has the value auto(3). Depending on the version of the device, it may not be able to report the pair orientation when it is decided automatically. The device will never have an orientation to report when If cgfeb100TpCrossConfig(22) has the value auto(3) and cgfeb100TpLink(17) has the value down(2)." ::= { cgfeb100Entry 23 } cgfeb100TPAutoNegot OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notSupported(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Enables or disables autonegtiation of link speed and duplex for twisted pair ports. Not supported on Fiber ports." ::= { cgfeb100Entry 24 } cgfeb100TPAdv10HDX OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notApplicable(3), enabledRO(4), disabledRO(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/disable control for these advertised autonegotiation modes. If autonegotiation is disabled (because cgfeb100TpAutonegot(24) has the value disabled(2) or cgfeb100ConfigMode(7) has the value hardware(2) and the Autonegotiation hardware switch is disabled), then these variables have no meaning and return read-only value notApplicable(3). If the value cannot be changed (because cgfeb100ConfigMode(7) has the value hardware(2)) and Autonegotiation is enabled, these variables return the read- only values enabledRO(4) or disabledRO(5)." ::= { cgfeb100Entry 25 } cgfeb100TPAdv10FDX OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notApplicable(3), enabledRO(4), disabledRO(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/disable control for these advertised autonegotiation modes. If autonegotiation is disabled (because cgfeb100TpAutonegot(24) has the value disabled(2) or cgfeb100ConfigMode(7) has the value hardware(2) and the Autonegotiation hardware switch is disabled), then these variables have no meaning and return read-only value notApplicable(3). If the value cannot be changed (because cgfeb100ConfigMode(7) has the value hardware(2)) and Autonegotiation is enabled, these variables return the read- only values enabledRO(4) or disabledRO(5)." ::= { cgfeb100Entry 26 } cgfeb100TPAdv100HDX OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notApplicable(3), enabledRO(4), disabledRO(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/disable control for these advertised autonegotiation modes. If autonegotiation is disabled (because cgfeb100TpAutonegot(24) has the value disabled(2) or cgfeb100ConfigMode(7) has the value hardware(2) and the Autonegotiation hardware switch is disabled), then these variables have no meaning and return read-only value notApplicable(3). If the value cannot be changed (because cgfeb100ConfigMode(7) has the value hardware(2)) and Autonegotiation is enabled, these variables return the read- only values enabledRO(4) or disabledRO(5)." ::= { cgfeb100Entry 27 } cgfeb100TPAdv100FDX OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notApplicable(3), enabledRO(4), disabledRO(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/disable control for these advertised autonegotiation modes. If autonegotiation is disabled (because cgfeb100TpAutonegot(24) has the value disabled(2) or cgfeb100ConfigMode(7) has the value hardware(2) and the Autonegotiation hardware switch is disabled), then these variables have no meaning and return read-only value notApplicable(3). If the value cannot be changed (because cgfeb100ConfigMode(7) has the value hardware(2)) and Autonegotiation is enabled, these variables return the read- only values enabledRO(4) or disabledRO(5)." ::= { cgfeb100Entry 28 } cgfeb100TPAdv1000HDX OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notApplicable(3), enabledRO(4), disabledRO(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/disable control for these advertised autonegotiation modes. If autonegotiation is disabled (because cgfeb100TpAutonegot(24) has the value disabled(2) or cgfeb100ConfigMode(7) has the value hardware(2) and the Autonegotiation hardware switch is disabled), then these variables have no meaning and return read-only value notApplicable(3). If the value cannot be changed (because cgfeb100ConfigMode(7) has the value hardware(2)) and Autonegotiation is enabled, these variables return the read- only values enabledRO(4) or disabledRO(5)." ::= { cgfeb100Entry 29 } cgfeb100TPAdv1000FDX OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notApplicable(3), enabledRO(4), disabledRO(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/disable control for these advertised autonegotiation modes. If autonegotiation is disabled (because cgfeb100TpAutonegot(24) has the value disabled(2) or cgfeb100ConfigMode(7) has the value hardware(2) and the Autonegotiation hardware switch is disabled), then these variables have no meaning and return read-only value notApplicable(3). If the value cannot be changed (because cgfeb100ConfigMode(7) has the value hardware(2)) and Autonegotiation is enabled, these variables return the read- only values enabledRO(4) or disabledRO(5)." ::= { cgfeb100Entry 30 } cgfeb100TPLpAdvPause OBJECT-TYPE SYNTAX INTEGER { symetric(1), asymRX(2), asymTX(3), disabled(4), notApplicable(5) } ACCESS read-only STATUS mandatory DESCRIPTION "This read-only variable shows the pause capability advertised by the twisted pair port's link partner. Values 1 through 4 for this variable are the same as those for cgfeb100TpAdvPause(38). If the device does not support the reporting of link partner autonegotiation or cgfeb100TpAutonegot(24) has the value disabled(2), this variable will have the value notApplicable(5)." ::= { cgfeb100Entry 31 } cgfeb100TPLpAdv10HDX OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notApplicable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This read-only variable shows twisted pair port's link partner's willingness to connect at 10Mbps Half Duplex. If the device does not support the reporting of link partner autonegotiation or cgfeb100TpAutonegot(24) has the value disabled(2), this variable will have the value notApplicable(3)." ::= { cgfeb100Entry 32 } cgfeb100TPLpAdv10FDX OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notApplicable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This read-only variable shows twisted pair port's link partner's willingness to connect at 10Mbps Full Duplex. If the device does not support the reporting of link partner autonegotiation or cgfeb100TpAutonegot(24) has the value disabled(2), this variable will have the value notApplicable(3)." ::= { cgfeb100Entry 33 } cgfeb100TPLpAdv100HDX OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notApplicable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This read-only variable shows twisted pair port's link partner's willingness to connect at 100Mbps Half Duplex. If the device does not support the reporting of link partner autonegotiation or cgfeb100TpAutonegot(24) has the value disabled(2), this variable will have the value notApplicable(3)." ::= { cgfeb100Entry 34 } cgfeb100TPLpAdv100FDX OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notApplicable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This read-only variable shows twisted pair port's link partner's willingness to connect at 100Mbps Full Duplex. If the device does not support the reporting of link partner autonegotiation or cgfeb100TpAutonegot(24) has the value disabled(2), this variable will have the value notApplicable(3)." ::= { cgfeb100Entry 35 } cgfeb100TPLpAdv1000HDX OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notApplicable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This read-only variable shows twisted pair port's link partner's willingness to connect at 1000Mbps Half Duplex. If the device does not support the reporting of link partner autonegotiation or cgfeb100TpAutonegot(24) has the value disabled(2), this variable will have the value notApplicable(3)." ::= { cgfeb100Entry 36 } cgfeb100TPLpAdv1000FDX OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notApplicable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This read-only variable shows twisted pair port's link partner's willingness to connect at 1000Mbps Full Duplex. If the device does not support the reporting of link partner autonegotiation or cgfeb100TpAutonegot(24) has the value disabled(2), this variable will have the value notApplicable(3)." ::= { cgfeb100Entry 37 } cgfeb100TPAdvPause OBJECT-TYPE SYNTAX INTEGER { symetric(1), asymRX(2), asymTX(3), disabled(4), notApplicable(5), symmetricRO(6), asymRXRO(7), asymTXRO(8), disabledRO(9) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/disable control for autonegotiation advertising of Twisted Pair Pause capability. Selectable values are symmetric(1), asymRX(2) (asymmetric, pause frames flow towards the converter), asymTX(3) (asymmetric, pause frames flow towards the link partner), and disabled(4). If autonegotiation is disabled (because cgfeb100TpAutonegot(24) has the value disabled(2) or cgfeb100ConfigMode(7) has the value hardware(2) and the Autonegotiation hardware switch is disabled), then this variable has no meaning and the read-only value notApplicable(5) is returned. When cgfeb100TpQosPause(39) has the value disabled(2), negotiated pause is suppressed and the read-only value notApplicable(5) is returned. If cgfeb100ConfigMode(7) has the value hardware(2) and the Autonegotiation hardware switch is enabled, then one of the following read-only values will be returned: symmetricRO(6), asymRXRO(7) (asymmetric, pause frames flow towards the converter), asymTXRO(8) (asymmetric, pause frames flow towards the link partner), and disabledRO(9)." ::= { cgfeb100Entry 38 } cgfeb100TPQosPause OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notApplicable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows Twisted Pair Quality Of Service Pause to be enabled or disabled. When cgfeb100QosEnabled(12) is set to enabled(1) and this variable is set to disabled(2), any pause functionality negotiated according to cgfeb100TpAdvPause(38) is suppressed. When cgfeb100QosEnabled(12) is set to disabled(2), this variable has the read-only value notApplicable(3)." ::= { cgfeb100Entry 39 } cgfeb100TPSacCfg OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows Source Address Change traps to be enabled or disabled. If enabled, 'Error' traps will be sent as frequently one per polling cycle any time the ethernet source address of any packet received on the Twisted Pair interface is different from the last address received on that interface during the previous polling cycle." ::= { cgfeb100Entry 40 } cgfeb100TPSacStat OBJECT-TYPE SYNTAX INTEGER { changed(1), constant(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This read-only variable has the value changed(1) if the Ethernet source address received on the Twisted Pair interface changed since the device's previous report to the Mangement Module, and the value constant(2) otherwise. To cause the Management Module to generate a trap when this occurs, set cgfeb100SacConfig(41) to enabled(1)." ::= { cgfeb100Entry 41 } cgfeb100ConnB OBJECT-TYPE SYNTAX CpsConnector ACCESS read-only STATUS mandatory DESCRIPTION "The style of Fiber connector built into this device." ::= { cgfeb100Entry 42 } cgfeb100FiberLink OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The Fiber Link status for this device." ::= { cgfeb100Entry 43 } cgfeb100FiberFullDuplexCfg OBJECT-TYPE SYNTAX INTEGER { fdx(1), hdx(2), auto(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The desired duplex setting of the Fiber interface. This can be set to fdx(1) (full duplex) or hdx(2) (half duplex). When cgfeb100TpAutonegot(24) has the value enabled(1) or cgfeb100ConfigMode(7) has the value hardware(2), this variable has the read-only value auto(3)." ::= { cgfeb100Entry 44 } cgfeb100FiberFullDuplexStat OBJECT-TYPE SYNTAX INTEGER { fdx(1), hdx(2), notApplicable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The actual duplex behavior of the Fiber interface: fdx(1) (full duplex) or hdx(2) (half duplex). If cgfeb100FiberAutonegot(46) has the value disabled(2) and this version of the device does not support manual fiber duplex control, Fiber duplex is forced to HDX. If cgfeb100FiberAutonegot(46) has the value enabled(1) and cgfeb100FiberLink(43) has the value down(2), then no duplex setting is available, and this variable has the value notApplicable(3)." ::= { cgfeb100Entry 45 } cgfeb100FiberAutoNegot OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notApplicable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Autonegotiation configuration. Fiber autonegotiation is limited to the duplex setting. The fiber's speed is fixed at 1000Mbps." ::= { cgfeb100Entry 46 } cgfeb100FiberAdv1000HDX OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notApplicable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/disable control for these advertised autonegotiation modes. If autonegotiation is disabled (because cgfeb100TpAutonegot(24) has the value disabled(2) or cgfeb100ConfigMode(7) has the value hardware(2) and the Autonegotiation hardware switch is disabled), then these variables have no meaning and return read-only value notApplicable(3). If the value cannot be changed (because cgfeb100ConfigMode(7) has the value hardware(2)) and Autonegotiation is enabled, these variables return the read-only values enabledRO(4) or disabledRO(5). If manual control of Fiber Autonegotiaion advertised modes is not supported by the device, this variable has no meaning and the read-only value notApplicable(3) is returned." ::= { cgfeb100Entry 47 } cgfeb100FiberAdv1000FDX OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notApplicable(3), enabledRO(4), disabledRO(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/disable control for these advertised autonegotiation modes. If autonegotiation is disabled (because cgfeb100TpAutonegot(24) has the value disabled(2) or cgfeb100ConfigMode(7) has the value hardware(2) and the Autonegotiation hardware switch is disabled), then these variables have no meaning and return read-only value notApplicable(3). If the value cannot be changed (because cgfeb100ConfigMode(7) has the value hardware(2)) and Autonegotiation is enabled, these variables return the read-only values enabledRO(4) or disabledRO(5). If manual control of Fiber Autonegotiaion advertised modes is not supported by the device, this variable has no meaning and the read-only value notApplicable(3) is returned." ::= { cgfeb100Entry 48 } cgfeb100FiberLpAdv1000HDX OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notApplicable(3), enabledRO(4), disabledRO(5) } ACCESS read-write STATUS mandatory DESCRIPTION "This configuration setting controls whether or not each port advertises willingness to connect at 1000Mbps, half duplex. This setting is not supported on fiber ports, and is ignored when autonegotiation is disabled." ::= { cgfeb100Entry 49 } cgfeb100FiberLpAdv1000FDX OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notApplicable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This configuration setting controls whether or not each port advertises willingness to connect at 1000Mbps, full duplex. This setting is not supported on fiber ports, and is ignored when autonegotiation is disabled." ::= { cgfeb100Entry 50 } cgfeb100FiberLpAdvPause OBJECT-TYPE SYNTAX INTEGER { symetric(1), asymRX(2), asymTX(3), disabled(4), notApplicable(5) } ACCESS read-only STATUS mandatory DESCRIPTION "This read-only variable shows the pause capability advertised by the fiber port's link partner. Values 1 through 4 for this variable are the same as those for cgfeb100TpAdvPause(38). If the device does not support the reporting of link partner autonegotiation or cgfeb100FiberAutonegot(46) has the value disabled(2), this variable will have the value notApplicable(5)." ::= { cgfeb100Entry 51 } cgfeb100FiberAdvPause OBJECT-TYPE SYNTAX INTEGER { symetric(1), asymRX(2), asymTX(3), disabled(4), notApplicable(5), symetricRO(6), asymRXRO(7), asymTXRO(8), disabledRO(9) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/disable control for autonegotiation advertising of Fiber Pause capability. Selectable values are symmetric(1), asymRX(2) (asymmetric, pause frames flow towards the converter), asymTX(3) (asymmetric, pause frames flow towards the link partner), and disabled(4). If autonegotiation is disabled (because cgfeb100FiberAutonegot(46) has the value disabled(2) or cgfeb100ConfigMode(7) has the value hardware(2) and the Autonegotiation hardware switch is disabled), then this variable has no meaning and the read-only value notApplicable(5) is returned. cgfeb100FiberQosPause(53) has the value disabled(2), negotiated pause is suppressed and the read-only value notApplicable(5) is returned. If cgfeb100ConfigMode(7) has the value hardware(2) and the Autonegotiation hardware switch is enabled, then one of the following read-only values will be returned: symmetricRO(6), asymRXRO(7) (asymmetric, pause frames flow towards the converter), asymTXRO(8) (asymmetric, pause frames flow towards the link partner), and disabledRO(9)." ::= { cgfeb100Entry 52 } cgfeb100FiberQosPause OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notApplicable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows Fiber Quality Of Service Pause to be enabled or disabled. When cgfeb100QosEnabled(12) is set to enabled(1) and this variable is set to disabled(2), any pause functionality negotiated according to cgfeb100FiberAdvPause(52) is suppressed. When cgfeb100QosEnabled(12) is set to disabled(2), this variable has the read-only value notApplicable(3)." ::= { cgfeb100Entry 53 } cgfeb100FiberSacCfg OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows Source Address Change traps to be enabled or disabled. If enabled, 'Error' traps will be sent as frequently one per polling cycle any time the ethernet source address of any packet received on the Fiber interface is different from the last address received on that interface during the previous polling cycle." ::= { cgfeb100Entry 54 } cgfeb100FiberSacStat OBJECT-TYPE SYNTAX INTEGER { changed(1), constant(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This read-only variable has the value changed(1) if the Ethernet source address received on the fiber interface changed since the device's previous report to the Mangement Module, and the value constant(2) otherwise. To cause the Management Module to generate a trap when this occurs, set cgfeb100FiberSacConfig(54) to enabled(1)." ::= { cgfeb100Entry 55 } cgfeb100MonitorTap OBJECT-TYPE SYNTAX INTEGER { transmit(1), receive(2), notInstalled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Before reading this description, see cgfeb100MonitorType(10). This variable controls which side of the fiber port (transmit(1) or receive(2)) is monitored by the monitoring port. If no monitoring port is present, this variable has the value notInstalled(3)." ::= { cgfeb100Entry 56 } cgfeb100CacheClean OBJECT-TYPE SYNTAX INTEGER { clean(1), dirty(2) } ACCESS read-only STATUS mandatory DESCRIPTION "When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2) Device and Management Module cache are not synchronized. The configuration currently displayed by the application has not been validated by the device. The device may need to correct the configuration, in which case the displayed configuration will change." ::= { cgfeb100Entry 57 } --===================================================================== -- Table for the crmfe100 crmfe100Table OBJECT-TYPE SYNTAX SEQUENCE OF Crmfe100Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Sparse table containing one entry for each CRMFE100 in the stack, indexed by cabinet serial number and slot." ::= { cpsSlotDetail 24 } crmfe100Entry OBJECT-TYPE SYNTAX Crmfe100Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Status and configuration entries for a single CRMFE100" INDEX { crmfe100BiaIndex, crmfe100SlotIndex } ::= { crmfe100Table 1 } Crmfe100Entry ::= SEQUENCE { crmfe100BiaIndex INTEGER, crmfe100SlotIndex INTEGER, crmfe100Groups DisplayString, crmfe100MRevision INTEGER, crmfe100CfgMatch INTEGER, crmfe100SerialNumber INTEGER, crmfe100ConnA INTEGER, crmfe100ConnB INTEGER, crmfe100TPLink INTEGER, crmfe100FiberLink INTEGER, crmfe100Fault INTEGER, crmfe100Autonegot INTEGER, crmfe100Enabled INTEGER, crmfe100Pause INTEGER, crmfe100LinkPassThrough INTEGER, crmfe100AutoCross INTEGER, crmfe100TPActivity INTEGER, crmfe100FiberActivity INTEGER, crmfe100ConfigMode INTEGER, crmfe100FarEndFault INTEGER, crmfe100NetworkMode INTEGER, crmfe100UpTime TimeTicks, crmfe100FirmwareRevision INTEGER, crmfe100RmtDetected INTEGER, crmfe100RmtTPLink INTEGER, crmfe100RmtFiberLink INTEGER, crmfe100RmtFault INTEGER, crmfe100RmtAutonegot INTEGER, crmfe100RmtPause INTEGER, crmfe100RmtLinkPassThrough INTEGER, crmfe100RmtAutoCross INTEGER, crmfe100RmtTPActivity INTEGER, crmfe100RmtFiberActivity INTEGER, crmfe100RmtConfigMode INTEGER, crmfe100RmtFarEndFault INTEGER, crmfe100RmtLoopback INTEGER, crmfe100RmtNetworkMode INTEGER, crmfe100RmtUpTime TimeTicks, crmfe100TxFxBwa INTEGER, crmfe100FxTxBwa INTEGER, crmfe100TxBytesH INTEGER, crmfe100TxBytesL INTEGER, crmfe100FxBytesH INTEGER, crmfe100FxBytesL INTEGER, crmfe100MscRxBytes INTEGER, crmfe100MscTxBytes INTEGER, crmfe100CacheClean INTEGER, crmfe100MbTxFxBwa INTEGER, crmfe100MbFxTxBwa INTEGER } crmfe100BiaIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number (BIA) of the cabinet in which the device is installed" ::= { crmfe100Entry 1 } crmfe100SlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The slot in which the device is installed" ::= { crmfe100Entry 2 } crmfe100Groups OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent can be instructed to apply configuration changes simultaneously to all group members rather than to individual devices. Every Groups string has three automatically defined implied values: 1) The model family of the device, e.g. 'CRMFE100' 2) The serial number of the cabinet in which the device is installed, in decimal with no leading zeroes, e.g. '12345', and 3) same as 2, with the slot in which the device is installed appended, enclosed in square brackets. e.g. '12345[9]'" ::= { crmfe100Entry 3 } crmfe100MRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The marketing revision of this device" ::= { crmfe100Entry 4 } crmfe100CfgMatch OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notApplicable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) indicates that cpsGroupCtrl.0 is null and therefore no comparison was performed." ::= { crmfe100Entry 5 } crmfe100SerialNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number of this device" ::= { crmfe100Entry 6 } crmfe100ConnA OBJECT-TYPE SYNTAX CpsConnector ACCESS read-only STATUS mandatory DESCRIPTION "The style of Fiber connector built into this device" ::= { crmfe100Entry 7 } crmfe100ConnB OBJECT-TYPE SYNTAX CpsConnector ACCESS read-only STATUS mandatory DESCRIPTION "The style of Copper connector built into this device" ::= { crmfe100Entry 8 } crmfe100TPLink OBJECT-TYPE SYNTAX INTEGER { linkUp(1), linkDown(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of Copper Link for this device" ::= { crmfe100Entry 9 } crmfe100FiberLink OBJECT-TYPE SYNTAX INTEGER { linkUp(1), linkDown(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of Fiber Link for this device" ::= { crmfe100Entry 10 } crmfe100Fault OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Value is yes(1) when either CopperLink or FiberLink has value linkDown(2)" ::= { crmfe100Entry 11 } crmfe100Autonegot OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Autonegotiation configuration for this device." ::= { crmfe100Entry 12 } crmfe100Enabled OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When the Enabled configuration item is set to no(2), the converter passes no network traffic in either direction." ::= { crmfe100Entry 13 } crmfe100Pause OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The Pause feature allows Ethernet MACs that support it to send data pacing 'Pause' messages to each other. Support for Pause is negotiated at the physical level and passed up to the MAC. While the MAC's Pause messages themselves can pass over the fiber link that this pair of media converters introduces, the TP physical layer negotiations to enable Pause can not. Therefore, if both end station MACs support Pause and wish to use it, the Pause negotiation must be re-generated by the media converters on both ends. By setting this configuration option to enabled(1), you are indicating to the local twisted pair station that the twisted pair station on the other side of the other media converter supports Pause and wishes to use it. This variable must be set consistently on both of the paired media converters." ::= { crmfe100Entry 14 } crmfe100LinkPassThrough OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This configuration item allows Link Pass Through to be enabled(1) or disabled(2). Link Passthrough causes loss of link on one side of a media converter to be passed through to the other side, so that upstream equipment can see fault conditions that would otherwise be hidden by the media converters." ::= { crmfe100Entry 15 } crmfe100AutoCross OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "On certain devices, it is possible for hardware to automatically correct errors in cable selection, making the distinction between a 'straight through' cable and a 'crossover' cable unimportant. This capability is known as Auto Cross. When disabled, the port reverts to MDI mode." ::= { crmfe100Entry 16 } crmfe100TPActivity OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notApplicable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Twisted Pair Activity. Some versions of the CRMFE100 do not support the reporting of interface activity. The value of this variable for such a device will be notApplicable." ::= { crmfe100Entry 17 } crmfe100FiberActivity OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notSupported(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Fiber Activity. Some versions of the CRMFE100 do not support the reporting of interface activity. The value of this variable for such a device will be notApplicable." ::= { crmfe100Entry 18 } crmfe100ConfigMode OBJECT-TYPE SYNTAX INTEGER { software(1), hardware(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all configuration control comes from physical switches or jumpers on the device." ::= { crmfe100Entry 19 } crmfe100FarEndFault OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Far End Fault configuration of this device. Far End Fault causes the fiber transmitter to generate a Far End Fault pattern upon the loss of a receiver signal detect. When the receiver detects signal again, the transmitter stops transmitting the Far End Fault pattern." ::= { crmfe100Entry 20 } crmfe100NetworkMode OBJECT-TYPE SYNTAX INTEGER { tokenRing(1), ethernet(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Read-only indicator for High Speed Token Ring jumper configuration. If the variable reads tokenRing(1), then the converter is jumpered for High Speed Token Ring mode. If the variable reads ethernet(2), then the converter is jumpered for Ethernet mode. The jumper settings for the converters on both ends of the fiber must be the same." ::= { crmfe100Entry 21 } crmfe100UpTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-write STATUS mandatory DESCRIPTION "Time since the last reboot in Time Ticks (hundredths of seconds). If the value 0 is written to this variable, the timer is reset. No other write value is accepted." ::= { crmfe100Entry 22 } crmfe100FirmwareRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Firmware revision level of this CRMFE100." ::= { crmfe100Entry 23 } crmfe100RmtDetected OBJECT-TYPE SYNTAX INTEGER { detected(1), notDetected(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Has the value yes(1) if management communcations have been established with a remote media converter." ::= { crmfe100Entry 24 } crmfe100RmtTPLink OBJECT-TYPE SYNTAX INTEGER { linkUp(1), linkDown(2), notApplicable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of Copper Link for this device" ::= { crmfe100Entry 25 } crmfe100RmtFiberLink OBJECT-TYPE SYNTAX INTEGER { linkUp(1), linkDown(2), notApplicable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of Fiber Link for this device" ::= { crmfe100Entry 26 } crmfe100RmtFault OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notApplicable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Value is yes(1) when either TPLink or FiberLink has value linkDown(2)" ::= { crmfe100Entry 27 } crmfe100RmtAutonegot OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notApplicable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Autonegotiation configuration for this device." ::= { crmfe100Entry 28 } crmfe100RmtPause OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notApplicable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The Pause feature allows Ethernet MACs that support it to send data pacing 'Pause' messages to each other. Support for Pause is negotiated at the physical level and passed up to the MAC. While the MAC's Pause messages themselves can pass over the fiber link that this pair of media converters introduces, the TP physical layer negotiations to enable Pause can not. Therefore, if both end station MACs support Pause and wish to use it, the Pause negotiation must be re-generated by the media converters on both ends. By setting this configuration option to enabled(1), you are indicating to the local twisted pair station that the twisted pair station on the other side of the other media converter supports Pause and wishes to use it. This variable must be set consistently on both of the paired media converters." ::= { crmfe100Entry 29 } crmfe100RmtLinkPassThrough OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notApplicable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This configuration item allows Link Pass Through to be enabled(1) or disabled(2). Link Passthrough causes loss of link on one side of a media converter to be passed through to the other side, so that upstream equipment can see fault conditions that would otherwise be hidden by the media converters." ::= { crmfe100Entry 30 } crmfe100RmtAutoCross OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notApplicable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "On certain devices, it is possible for hardware to automatically correct errors in cable selection, making the distinction between a 'straight through' cable and a 'crossover' cable unimportant. This capability is known as Auto Cross. When disabled, the port reverts to MDI mode." ::= { crmfe100Entry 31 } crmfe100RmtTPActivity OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notSupported(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Twisted Pair Activity. Some versions of the CRMFE100 do not support the reporting of interface activity. The value of this variable for such a device will be notApplicable." ::= { crmfe100Entry 32 } crmfe100RmtFiberActivity OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notSupported(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Fiber Activity. Some versions of the CRMFE100 do not support the reporting of interface activity. The value of this variable for such a device will be notApplicable." ::= { crmfe100Entry 33 } crmfe100RmtConfigMode OBJECT-TYPE SYNTAX INTEGER { software(1), hardware(2), notApplicable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all configuration control comes from physical switches or jumpers on the device." ::= { crmfe100Entry 34 } crmfe100RmtFarEndFault OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notApplicable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Far End Fault configuration of this device. Far End Fault causes the fiber transmitter to generate a Far End Fault pattern upon the loss of a receiver signal detect. When the receiver detects signal again, the transmitter stops transmitting the Far End Fault pattern." ::= { crmfe100Entry 35 } crmfe100RmtLoopback OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notApplicable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "When Remote Loopback is enabled, all packets sent out from the local fiber interface are reflected back by the remote converter rather than being passed out through the remote twisted pair interface, and all packets received on the remote Twisted Pair interface are discarded." ::= { crmfe100Entry 36 } crmfe100RmtNetworkMode OBJECT-TYPE SYNTAX INTEGER { tokenRing(1), ethernet(2), notApplicable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Read-only indicator for High Speed Token Ring jumper configuration. If the variable reads tokenRing(1), then the converter is jumpered for High Speed Token Ring mode. If the variable reads ethernet(2), then the converter is jumpered for Ethernet mode. The jumper settings for the converters on both ends of the fiber must be the same." ::= { crmfe100Entry 37 } crmfe100RmtUpTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-write STATUS mandatory DESCRIPTION "Time since the last reboot in Time Ticks (hundredths of seconds). If the value 0 is written to this variable, the timer is reset. No other write value is accepted." ::= { crmfe100Entry 38 } crmfe100TxFxBwa OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows the control of bandwidth allocation. The value of this variable is entered in Kilobytes per Second, and is automatically rounded to the nearest 64KBps. A value of zero disables data transfer, and the maximum value is 12224KBps. Data traffic is measured from the beginning of each second. Once the traffic reaches the cap specified, all traffic is discarded until the start of the next second, when the counters are reset and traffic begins to flow again. crmfe100TxFxBwa(39) limits the data flowing from the Twisted Pair interface to the Fiber interface." ::= { crmfe100Entry 39 } crmfe100FxTxBwa OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows the control of bandwidth allocation. The value of this variable is entered in Kilobytes per Second, and is automatically rounded to the nearest 64KBps. A value of zero disables data transfer, and the maximum value is 12224KBps. Data traffic is measured from the beginning of each second. Once the traffic reaches the cap specified, all traffic is discarded until the start of the next second, when the counters are reset and traffic begins to flow again. crmfe100FxTxBwa(39) limits the data flowing from the fiber interface to the twisted pair interface." ::= { crmfe100Entry 40 } crmfe100TxBytesH OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "These variables measure the traffic (in Bytes) received by the two interfaces of the converter (and therefore transmitted by the opposite interface). 'Tx' refers to data received by the Twisted Pair interface (and transmitted on the Fiber interface), and 'Fx' refers to data received on the Fiber interface (and transmitted on the Twisted Pair interface). In order to limit each variable to the 32-bit maximum commonly supported in the SNMP world, these 64-bit counters are split into a high-order and low-order 32-bit sections. Transition Networks' applications generally treat the High order portion of the counter as a counter of the number of times the Low order section has wrapped to 0. To reconstruct the original 64-bit value, multiply the 'High' section by 2^32 and add the 'Low' section. If you write the value 0 to any of these four variables, all four are reset to zero." ::= { crmfe100Entry 41 } crmfe100TxBytesL OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "See the DESCRIPTION for cfmfe100TxBytesH(42) above." ::= { crmfe100Entry 42 } crmfe100FxBytesH OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "See the DESCRIPTION for cfmfe100TxBytesH(42) above." ::= { crmfe100Entry 43 } crmfe100FxBytesL OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "See the DESCRIPTION for cfmfe100TxBytesH(42) above." ::= { crmfe100Entry 44 } crmfe100MscRxBytes OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This variable measures the traffic (in Bytes) received and transmitted by the Management Subchannel within the Fiber interface. 'Management Subchannel' refers to the transfer of management data to and from the Remote SRMFExxx in the inter-packet gaps normally found in Ethernet traffic. This allows management data to be transferred with no reduction in the bandwidth available for normal network traffic. If you write the value 0 to this variable or crmfe100MscTxBytes(47), both are reset to zero." ::= { crmfe100Entry 45 } crmfe100MscTxBytes OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This variable measures the traffic (in Bytes) received and transmitted by the Management Subchannel within the Fiber interface. 'Management Subchannel' refers to the transfer of management data to and from the Remote SRMFExxx in the inter-packet gaps normally found in Ethernet traffic. This allows management data to be transferred with no reduction in the bandwidth available for normal network traffic. If you write the value 0 to this variable or crmfe100MscRxBytes(46), both are reset to zero." ::= { crmfe100Entry 46 } crmfe100CacheClean OBJECT-TYPE SYNTAX INTEGER { clean(1), dirty(2) } ACCESS read-only STATUS mandatory DESCRIPTION "When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2) Device and Management Module cache are not synchronized. The configuration currently displayed by the application has not been validated by the device. The device may need to correct the configuration, in which case the displayed configuration will change." ::= { crmfe100Entry 47 } crmfe100MbTxFxBwa OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows the control of bandwidth allocation. The value of this variable is entered in Megabits per Second, and is automatically rounded to the nearest 64KBps. A value of zero disables data transfer, and the maximum value is 12224KBps. Data traffic is measured from the beginning of each second. Once the traffic reaches the cap specified, all traffic is discarded until the start of the next second, when the counters are reset and traffic begins to flow again. crmfe100MbTxFxBwa(48) limits the data flowing from the Twisted Pair interface to the Fiber interface. This variable does the same thing as crmfe100TxFxBwa(39), only the units are different." ::= { crmfe100Entry 48 } crmfe100MbFxTxBwa OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows the control of bandwidth allocation. The value of this variable is entered in Megabits per Second, and is automatically rounded to the nearest 64KBps. A value of zero disables data transfer, and the maximum value is 12224KBps. Data traffic is measured from the beginning of each second. Once the traffic reaches the cap specified, all traffic is discarded until the start of the next second, when the counters are reset and traffic begins to flow again. crmfe100MbFxTxBwa(49) limits the data flowing from the fiber interface to the twisted pair interface. This variable does the same thing as crmfe100TxFxBwa(40), only the units are different." ::= { crmfe100Entry 49 } -- ================================================================== -- Table for a crs2f100 slide in card. crs2f100Table OBJECT-TYPE SYNTAX SEQUENCE OF Crs2f100Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Sparse table containing one entry for each CRS2F100 in the stack, indexed by cabinet serial number and slot." ::= { cpsSlotDetail 25 } crs2f100Entry OBJECT-TYPE SYNTAX Crs2f100Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Status and configuration entries for a single CRS2F100" INDEX { crs2f100BiaIndex, crs2f100SlotIndex } ::= { crs2f100Table 1 } Crs2f100Entry ::= SEQUENCE { crs2f100BiaIndex INTEGER, crs2f100SlotIndex INTEGER, crs2f100Groups DisplayString, crs2f100MRevision INTEGER, crs2f100CfgMatch INTEGER, crs2f100SerialNumber INTEGER, crs2f100ConnA INTEGER, crs2f100ConnB INTEGER, crs2f100FiberLink INTEGER, crs2f100Fault INTEGER, crs2f100FirmwareRevision INTEGER, crs2f100Loopback INTEGER, crs2f100DCE INTEGER, crs2f100CopperActivity INTEGER, crs2f100ConfigMode INTEGER, crs2f100RmtDetected INTEGER, crs2f100RmtLoopback INTEGER, crs2f100RmtDCE INTEGER, crs2f100RmtCopperActivity INTEGER, crs2f100RmtConfigMode INTEGER, crs2f100CacheClean INTEGER } crs2f100BiaIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number (BIA) of the cabinet in which the device is installed" ::= { crs2f100Entry 1 } crs2f100SlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The slot in which the device is installed" ::= { crs2f100Entry 2 } crs2f100Groups OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent can be instructed to apply configuration changes simultaneously to all group members rather than to individual devices. Every Groups string has three automatically defined implied values: 1) The model family of the device, e.g. 'CRS2F100' 2) The serial number of the cabinet in which the device is installed, in decimal with no leading zeroes, e.g. '12345', and 3) same as 2, with the slot in which the device is installed appended, enclosed in square brackets. e.g. '12345[9]'" ::= { crs2f100Entry 3 } crs2f100MRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The marketing revision of this device" ::= { crs2f100Entry 4 } crs2f100CfgMatch OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notApplicable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) indicates that cpsGroupCtrl.0 is null and therefore no comparison was performed." ::= { crs2f100Entry 5 } crs2f100SerialNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number of this device" ::= { crs2f100Entry 6 } crs2f100ConnA OBJECT-TYPE SYNTAX CpsConnector ACCESS read-only STATUS mandatory DESCRIPTION "The style of Fiber connector built into this device" ::= { crs2f100Entry 7 } crs2f100ConnB OBJECT-TYPE SYNTAX CpsConnector ACCESS read-only STATUS mandatory DESCRIPTION "The style of Copper connector built into this device" ::= { crs2f100Entry 8 } crs2f100FiberLink OBJECT-TYPE SYNTAX INTEGER { linkUp(1), linkDown(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of Fiber Link for this device" ::= { crs2f100Entry 9 } crs2f100Fault OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Value is yes(1) when FiberLink has value linkDown(2)" ::= { crs2f100Entry 10 } crs2f100FirmwareRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The Firmware Revision MIB Variable reports the revision of software running on the processor on this particular device. You can discover the revisions on these devices by entering the PICREV command at the command line interface. Device Firmware Revisions are normally discussed in terms of a single letter, e.g. revision 'B'. However, when the firmware revision is displayed by generic MIB processing code that is unaware of this convention, the revision is displayed as a decimal value. The table in crs2f100.html provides some examples of how decimal revision values correspond to letter revision values." ::= { crs2f100Entry 11 } crs2f100Loopback OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Loopback is a testing aid available on several different products. When Loopback is enabled on an interface, all data that is sent to the interface is reflected back to the sender, and the actual condition (or even existence) of the equipment on the opposite interface is ignored." ::= { crs2f100Entry 12 } crs2f100DCE OBJECT-TYPE SYNTAX INTEGER { dCE(1), dTE(2) } ACCESS read-only STATUS mandatory DESCRIPTION "An indication of whether this device is attached to a DCE (a modem) or a DTE (a terminal or computer)." ::= { crs2f100Entry 13 } crs2f100CopperActivity OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The activity indicator has the value yes(1) when the hardware has recently detected network traffic on the associated network port, and no(2) otherwise." ::= { crs2f100Entry 14 } crs2f100ConfigMode OBJECT-TYPE SYNTAX INTEGER { software(1), hardware(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all configuration control comes from physical switches or jumpers on the device." ::= { crs2f100Entry 15 } crs2f100RmtDetected OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Has the value yes(1) if management communcations have been established with a remote media device." ::= { crs2f100Entry 16 } crs2f100RmtLoopback OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notApplicable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Loopback is a testing aid available on several different products. When Loopback is enabled on an interface, all data that is sent to the interface is reflected back to the sender, and the actual condition (or even existence) of the equipment on the opposite interface is ignored. When no remote device is present, this variable has the value notApplicable(3)." ::= { crs2f100Entry 17 } crs2f100RmtDCE OBJECT-TYPE SYNTAX INTEGER { dCE(1), dTE(2), notApplicable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This variable describes the status of a remotely managed device. This is an indicator of whether this device is attached to a DCE (a modem) or a DTE (a terminal or computer). When no remote device is present, this variable has the value notApplicable(3)." ::= { crs2f100Entry 18 } crs2f100RmtCopperActivity OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notApplicable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The activity indicator has the value yes(1) when the hardware has recently detected network traffic on the associated network port, and no(2) otherwise. When no remote device is present, this variable has the value notApplicable(3)." ::= { crs2f100Entry 19 } crs2f100RmtConfigMode OBJECT-TYPE SYNTAX INTEGER { software(1), hardware(2), notApplicable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all configuration control comes from physical switches or jumpers on the device. When no remote device is present, this variable has the value notApplicable(3)." ::= { crs2f100Entry 20 } crs2f100CacheClean OBJECT-TYPE SYNTAX INTEGER { clean(1), dirty(2) } ACCESS read-only STATUS mandatory DESCRIPTION "When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2) Device and Management Module cache are not synchronized. The configuration currently displayed by the application has not been validated by the device. The device may need to correct the configuration, in which case the displayed configuration will change." ::= { crs2f100Entry 21 } -- ================================================================== -- Table for a crs4f100 slide in card. crs4f100Table OBJECT-TYPE SYNTAX SEQUENCE OF Crs4f100Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Sparse table containing one entry for each CRS4F100 in the stack, indexed by cabinet serial number and slot." ::= { cpsSlotDetail 26 } crs4f100Entry OBJECT-TYPE SYNTAX Crs4f100Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Status and configuration entries for a single CRS4F100" INDEX { crs4f100BiaIndex, crs4f100SlotIndex } ::= { crs4f100Table 1 } Crs4f100Entry ::= SEQUENCE { crs4f100BiaIndex INTEGER, crs4f100SlotIndex INTEGER, crs4f100Groups DisplayString, crs4f100MRevision INTEGER, crs4f100CfgMatch INTEGER, crs4f100SerialNumber INTEGER, crs4f100ConnA INTEGER, crs4f100ConnB INTEGER, crs4f100FiberLink INTEGER, crs4f100Fault INTEGER, crs4f100FirmwareRevision INTEGER, crs4f100CopperActivity INTEGER, crs4f100CacheClean INTEGER } crs4f100BiaIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number (BIA) of the cabinet in which the device is installed" ::= { crs4f100Entry 1 } crs4f100SlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The slot in which the device is installed" ::= { crs4f100Entry 2 } crs4f100Groups OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent can be instructed to apply configuration changes simultaneously to all group members rather than to individual devices. Every Groups string has three automatically defined implied values: 1) The model family of the device, e.g. 'CRS4F100' 2) The serial number of the cabinet in which the device is installed, in decimal with no leading zeroes, e.g. '12345', and 3) same as 2, with the slot in which the device is installed appended, enclosed in square brackets. e.g. '12345[9]'" ::= { crs4f100Entry 3 } crs4f100MRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The marketing revision of this device" ::= { crs4f100Entry 4 } crs4f100CfgMatch OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notApplicable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) indicates that cpsGroupCtrl.0 is null and therefore no comparison was performed." ::= { crs4f100Entry 5 } crs4f100SerialNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number of this device" ::= { crs4f100Entry 6 } crs4f100ConnA OBJECT-TYPE SYNTAX CpsConnector ACCESS read-only STATUS mandatory DESCRIPTION "The style of Fiber connector built into this device" ::= { crs4f100Entry 7 } crs4f100ConnB OBJECT-TYPE SYNTAX CpsConnector ACCESS read-only STATUS mandatory DESCRIPTION "The style of Copper connector built into this device" ::= { crs4f100Entry 8 } crs4f100FiberLink OBJECT-TYPE SYNTAX INTEGER { linkUp(1), linkDown(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of Fiber Link for this device" ::= { crs4f100Entry 9 } crs4f100Fault OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Value is yes(1) when FiberLink has value linkDown(2)" ::= { crs4f100Entry 10 } crs4f100FirmwareRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The Firmware Revision MIB Variable reports the revision of software running on the processor on this particular device. You can discover the revisions on these devices by entering the PICREV command at the command line interface. Device Firmware Revisions are normally discussed in terms of a single letter, e.g. revision 'B'. However, when the firmware revision is displayed by generic MIB processing code that is unaware of this convention, the revision is displayed as a decimal value. The table in crs4f100.html provides some examples of how decimal revision values correspond to letter revision values." ::= { crs4f100Entry 11 } crs4f100CopperActivity OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The activity indicator has the value yes(1) when the hardware has recently detected network traffic on the associated network port, and no(2) otherwise." ::= { crs4f100Entry 12 } crs4f100CacheClean OBJECT-TYPE SYNTAX INTEGER { clean(1), dirty(2) } ACCESS read-only STATUS mandatory DESCRIPTION "When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2) Device and Management Module cache are not synchronized. The configuration currently displayed by the application has not been validated by the device. The device may need to correct the configuration, in which case the displayed configuration will change." ::= { crs4f100Entry 13 } -- ================================================================== -- Table for a cmefg100 slide in card. cmefg100Table OBJECT-TYPE SYNTAX SEQUENCE OF Cmefg100Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Generated CMEFG100 MIB Version 041110a " ::= { cpsSlotDetail 27 } cmefg100Entry OBJECT-TYPE SYNTAX Cmefg100Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Status and configuration entries for a single CMEFG100" INDEX { cmefg100SubDeviceIndex, cmefg100BiaIndex, cmefg100SlotIndex } ::= { cmefg100Table 1 } Cmefg100Entry ::= SEQUENCE { cmefg100SubDeviceIndex INTEGER, cmefg100BiaIndex INTEGER, cmefg100SlotIndex INTEGER, cmefg100Groups DisplayString, cmefg100MRevision INTEGER, cmefg100CfgMatch INTEGER, cmefg100ImcLocEnable INTEGER, cmefg100ImcLocReset INTEGER, cmefg100ImcRmtEnable INTEGER, cmefg100ImcRmtReset INTEGER, cmefg100ImcRxAlignmentErrorsTbl INTEGER, cmefg100ImcRxBroadcastPktsTbl INTEGER, cmefg100ImcRxDropPktsTbl INTEGER, cmefg100ImcRxExcessSizeDiscTbl INTEGER, cmefg100ImcRxFCSErrorsTbl INTEGER, cmefg100ImcRxFragmentsTbl INTEGER, cmefg100ImcRxGoodOctetsTbl INTEGER, cmefg100ImcRxGoodOctetsWrapTbl INTEGER, cmefg100ImcRxJabbersTbl INTEGER, cmefg100ImcRxMulticastPktsTbl INTEGER, cmefg100ImcRxOctetsTbl INTEGER, cmefg100ImcRxOctetsWrapTbl INTEGER, cmefg100ImcRxOversizePktsTbl INTEGER, cmefg100ImcRxPausePktsTbl INTEGER, cmefg100ImcRxPkts1024to1522OctetsTbl INTEGER, cmefg100ImcRxPkts128to255OctetsTbl INTEGER, cmefg100ImcRxPkts256to511OctetsTbl INTEGER, cmefg100ImcRxPkts512to1023OctetsTbl INTEGER, cmefg100ImcRxPkts64OctetsTbl INTEGER, cmefg100ImcRxPkts65to127OctetsTbl INTEGER, cmefg100ImcRxQosOctetsTbl INTEGER, cmefg100ImcRxQosOctetsWrapTbl INTEGER, cmefg100ImcRxQosPktsTbl INTEGER, cmefg100ImcRxSAChangesTbl INTEGER, cmefg100ImcRxSymbolErrorTbl INTEGER, cmefg100ImcRxUndersizePktsTbl INTEGER, cmefg100ImcRxUnicastPktsTbl INTEGER, cmefg100ImcTxBroadcastPktsTbl INTEGER, cmefg100ImcTxCollisionsTbl INTEGER, cmefg100ImcTxDeferredTransmitTbl INTEGER, cmefg100ImcTxDropPktsTbl INTEGER, cmefg100ImcTxExcessiveCollisionTbl INTEGER, cmefg100ImcTxFrameInDiscTbl INTEGER, cmefg100ImcTxLateCollisionTbl INTEGER, cmefg100ImcTxMulticastPktsTbl INTEGER, cmefg100ImcTxMultipleCollisionTbl INTEGER, cmefg100ImcTxOctetsTbl INTEGER, cmefg100ImcTxOctetsWrapTbl INTEGER, cmefg100ImcTxPausePktsTbl INTEGER, cmefg100ImcTxQosOctetsTbl INTEGER, cmefg100ImcTxQosOctetsWrapTbl INTEGER, cmefg100ImcTxQosPktsTbl INTEGER, cmefg100ImcTxSingleCollisionTbl INTEGER, cmefg100ImcTxUnicastPktsTbl INTEGER, cmefg100LadCacheCmd INTEGER, cmefg100LadCacheState INTEGER, cmefg100LadEditCmd INTEGER, cmefg100LadEditMac OCTET STRING, cmefg100LadEditPort INTEGER, cmefg100LadEditVid INTEGER, cmefg100LadEntries INTEGER, cmefg100LadMacTbl MacAddress, cmefg100LadPortTbl INTEGER, cmefg100LadStaticTbl INTEGER, cmefg100LadVidTbl INTEGER, cmefg100LocColdstart INTEGER, cmefg100LocDmiRxPower INTEGER, cmefg100LocDmiRxPowerAlarm INTEGER, cmefg100LocDmiTemp INTEGER, cmefg100LocDmiTempAlarm INTEGER, cmefg100LocDmiTxBiasAlarm INTEGER, cmefg100LocDmiTxBiasCurrent INTEGER, cmefg100LocDmiTxPower INTEGER, cmefg100LocDmiTxPowerAlarm INTEGER, cmefg100LocFiberAdv1000FDX INTEGER, cmefg100LocFiberAdv1000HDX INTEGER, cmefg100LocFiberAutoNegot INTEGER, cmefg100LocFiberConnA CpsConnector, cmefg100LocFiberDuplex INTEGER, cmefg100LocFiberLink INTEGER, cmefg100LocFiberPause INTEGER, cmefg100LocFiberQosPause INTEGER, cmefg100LocFiberSacEnable INTEGER, cmefg100LocFiberSacStatus INTEGER, cmefg100LocFirmwareRevision INTEGER, cmefg100LocFpgaRev INTEGER, cmefg100LocFxTxBwaKb INTEGER, cmefg100LocFxTxBwaMb INTEGER, cmefg100LocOamActiveMode INTEGER, cmefg100LocOamAdminControl INTEGER, cmefg100LocOamConfigRevision INTEGER, cmefg100LocOamControlInUnknownOpcodes INTEGER, cmefg100LocOamCriticalEvent INTEGER, cmefg100LocOamDuplicateEventNotificationRx INTEGER, cmefg100LocOamFramesLostDueToOamError INTEGER, cmefg100LocOamInformationRx INTEGER, cmefg100LocOamInformationTx INTEGER, cmefg100LocOamLastGasp INTEGER, cmefg100LocOamLinkEvents INTEGER, cmefg100LocOamLinkFault INTEGER, cmefg100LocOamLocDteDisc INTEGER, cmefg100LocOamLoopbackControlRx INTEGER, cmefg100LocOamLoopbackControlTx INTEGER, cmefg100LocOamMacAddress MacAddress, cmefg100LocOamMaxOamPduSize INTEGER, cmefg100LocOamMultiplexorState INTEGER, cmefg100LocOamOperStatus INTEGER, cmefg100LocOamOrgSpecificRx INTEGER, cmefg100LocOamOrgSpecificTx INTEGER, cmefg100LocOamParserState INTEGER, cmefg100LocOamRmtDteDisc INTEGER, cmefg100LocOamRmtLoopback INTEGER, cmefg100LocOamUnidirectional INTEGER, cmefg100LocOamVarRetrieval INTEGER, cmefg100LocSelfTestFailed INTEGER, cmefg100LocSerialNumber INTEGER, cmefg100LocTpAdv1000FDX INTEGER, cmefg100LocTpAdv1000HDX INTEGER, cmefg100LocTpAdv100FDX INTEGER, cmefg100LocTpAdv100HDX INTEGER, cmefg100LocTpAdv10FDX INTEGER, cmefg100LocTpAdv10HDX INTEGER, cmefg100LocTpAutoNegot INTEGER, cmefg100LocTpConnB CpsConnector, cmefg100LocTpCross INTEGER, cmefg100LocTpDuplex INTEGER, cmefg100LocTpLink INTEGER, cmefg100LocTpPause INTEGER, cmefg100LocTpQosPause INTEGER, cmefg100LocTpSacEnable INTEGER, cmefg100LocTpSacStatus INTEGER, cmefg100LocTpSpeed INTEGER, cmefg100LocTxFxBwaKb INTEGER, cmefg100LocTxFxBwaMb INTEGER, cmefg100LocUptime TimeTicks, cmefg100QosHqWeight INTEGER, cmefg100QosLqWeight INTEGER, cmefg100QosPriority INTEGER, cmefg100RmtColdStart INTEGER, cmefg100RmtDetected INTEGER, cmefg100RmtDmiRxPower INTEGER, cmefg100RmtDmiRxPowerAlarm INTEGER, cmefg100RmtDmiTemp INTEGER, cmefg100RmtDmiTempAlarm INTEGER, cmefg100RmtDmiTxBiasAlarm INTEGER, cmefg100RmtDmiTxBiasCurrent INTEGER, cmefg100RmtDmiTxPower INTEGER, cmefg100RmtDmiTxPowerAlarm INTEGER, cmefg100RmtFactoryReset INTEGER, cmefg100RmtFiberAutoNegot INTEGER, cmefg100RmtFiberLink INTEGER, cmefg100RmtFiberPause INTEGER, cmefg100RmtFiberQosPause INTEGER, cmefg100RmtFirmwareRevision INTEGER, cmefg100RmtFpgaRev INTEGER, cmefg100RmtOamActiveMode INTEGER, cmefg100RmtOamCriticalEvent INTEGER, cmefg100RmtOamLastGasp INTEGER, cmefg100RmtOamLinkEvents INTEGER, cmefg100RmtOamLinkFault INTEGER, cmefg100RmtOamLocDteDisc INTEGER, cmefg100RmtOamPeerConfigRevision INTEGER, cmefg100RmtOamPeerMacAddress MacAddress, cmefg100RmtOamPeerMaxOamPduSize INTEGER, cmefg100RmtOamPeerMultiplexorState INTEGER, cmefg100RmtOamPeerParserState INTEGER, cmefg100RmtOamPeerVendorInfo OCTET STRING, cmefg100RmtOamPeerVendorOui OCTET STRING, cmefg100RmtOamRmtDteDisc INTEGER, cmefg100RmtOamRmtLoopback INTEGER, cmefg100RmtOamUnidirectional INTEGER, cmefg100RmtOamVarRetrieval INTEGER, cmefg100RmtSelfTestFailed INTEGER, cmefg100RmtSerialNumber INTEGER, cmefg100RmtTpAdv1000FDX INTEGER, cmefg100RmtTpAdv1000HDX INTEGER, cmefg100RmtTpAdv100FDX INTEGER, cmefg100RmtTpAdv100HDX INTEGER, cmefg100RmtTpAdv10FDX INTEGER, cmefg100RmtTpAdv10HDX INTEGER, cmefg100RmtTpAutoNegot INTEGER, cmefg100RmtTpCross INTEGER, cmefg100RmtTpDuplex INTEGER, cmefg100RmtTpLink INTEGER, cmefg100RmtTpPause INTEGER, cmefg100RmtTpQosPause INTEGER, cmefg100RmtTpSpeed INTEGER, cmefg100RmtUptime TimeTicks, cmefg100VlanCacheCmd INTEGER, cmefg100VlanCacheState INTEGER, cmefg100VlanEditCmd INTEGER, cmefg100VlanEditFwdFiber INTEGER, cmefg100VlanEditFwdTp INTEGER, cmefg100VlanEditUntagFiber INTEGER, cmefg100VlanEditUntagTp INTEGER, cmefg100VlanEditVid INTEGER, cmefg100VlanEnable INTEGER, cmefg100VlanEntries INTEGER, cmefg100VlanFiberDefaultPri INTEGER, cmefg100VlanFiberDefaultVid INTEGER, cmefg100VlanFiberInUntaggedDrop INTEGER, cmefg100VlanFwdFiberTbl INTEGER, cmefg100VlanFwdTpTbl INTEGER, cmefg100VlanIngressVidHitNoMem INTEGER, cmefg100VlanIngressVidMiss INTEGER, cmefg100VlanPriMapTbl INTEGER, cmefg100VlanPriTagCtrl INTEGER, cmefg100VlanSetFailed INTEGER, cmefg100VlanTagIn INTEGER, cmefg100VlanTpDefaultPri INTEGER, cmefg100VlanTpDefaultVid INTEGER, cmefg100VlanTpInUntaggedDrop INTEGER, cmefg100VlanUntagFiberTbl INTEGER, cmefg100VlanUntagTpTbl INTEGER, cmefg100VlanVidTagCtrl INTEGER, cmefg100VlanVidTbl INTEGER, cmefg100CacheClean INTEGER } cmefg100SubDeviceIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "If the name of a particular MIB variable does not end in 'Tbl', then it uses the placeholder value '1' in the subdevice index column. " ::= { cmefg100Entry 1 } cmefg100BiaIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 2 } cmefg100SlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 3 } cmefg100Groups OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 4 } cmefg100MRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 5 } cmefg100CfgMatch OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 6 } cmefg100ImcLocEnable OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable periodic upload of local Interface MIB Counters from CMEFG100 to Agent. cmefg100ImcxxxTbl subdevice 1=local tp, subdevice 2=local fiber. " ::= { cmefg100Entry 7 } cmefg100ImcLocReset OBJECT-TYPE SYNTAX INTEGER { reset(1), doNothing(2) } ACCESS read-write STATUS mandatory DESCRIPTION "set to reset(1) to clear all local cmefg100Imc counters. " ::= { cmefg100Entry 8 } cmefg100ImcRmtEnable OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable periodic upload of remote Interface MIB Counters from CMEFG100 to Agent. cmefg100ImcxxxTbl subdevice 3=remote tp, subdevice 4=remote fiber. " ::= { cmefg100Entry 9 } cmefg100ImcRmtReset OBJECT-TYPE SYNTAX INTEGER { reset(1), doNothing(2) } ACCESS read-write STATUS mandatory DESCRIPTION "set to reset(1) to clear all remote cmefg100Imc counters. " ::= { cmefg100Entry 10 } cmefg100ImcRxAlignmentErrorsTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 11 } cmefg100ImcRxBroadcastPktsTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 12 } cmefg100ImcRxDropPktsTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 13 } cmefg100ImcRxExcessSizeDiscTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 14 } cmefg100ImcRxFCSErrorsTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 15 } cmefg100ImcRxFragmentsTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 16 } cmefg100ImcRxGoodOctetsTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 17 } cmefg100ImcRxGoodOctetsWrapTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 18 } cmefg100ImcRxJabbersTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 19 } cmefg100ImcRxMulticastPktsTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 20 } cmefg100ImcRxOctetsTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 21 } cmefg100ImcRxOctetsWrapTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 22 } cmefg100ImcRxOversizePktsTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 23 } cmefg100ImcRxPausePktsTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 24 } cmefg100ImcRxPkts1024to1522OctetsTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 25 } cmefg100ImcRxPkts128to255OctetsTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 26 } cmefg100ImcRxPkts256to511OctetsTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 27 } cmefg100ImcRxPkts512to1023OctetsTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 28 } cmefg100ImcRxPkts64OctetsTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 29 } cmefg100ImcRxPkts65to127OctetsTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 30 } cmefg100ImcRxQosOctetsTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 31 } cmefg100ImcRxQosOctetsWrapTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 32 } cmefg100ImcRxQosPktsTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 33 } cmefg100ImcRxSAChangesTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 34 } cmefg100ImcRxSymbolErrorTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 35 } cmefg100ImcRxUndersizePktsTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 36 } cmefg100ImcRxUnicastPktsTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 37 } cmefg100ImcTxBroadcastPktsTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 38 } cmefg100ImcTxCollisionsTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 39 } cmefg100ImcTxDeferredTransmitTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 40 } cmefg100ImcTxDropPktsTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 41 } cmefg100ImcTxExcessiveCollisionTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 42 } cmefg100ImcTxFrameInDiscTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 43 } cmefg100ImcTxLateCollisionTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 44 } cmefg100ImcTxMulticastPktsTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 45 } cmefg100ImcTxMultipleCollisionTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 46 } cmefg100ImcTxOctetsTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 47 } cmefg100ImcTxOctetsWrapTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 48 } cmefg100ImcTxPausePktsTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 49 } cmefg100ImcTxQosOctetsTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 50 } cmefg100ImcTxQosOctetsWrapTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 51 } cmefg100ImcTxQosPktsTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 52 } cmefg100ImcTxSingleCollisionTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 53 } cmefg100ImcTxUnicastPktsTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 54 } cmefg100LadCacheCmd OBJECT-TYPE SYNTAX INTEGER { loadCache(1), doNothing(2), release(3) } ACCESS read-write STATUS mandatory DESCRIPTION "All variables starting with cmefg100Lad relate to the Learned MAC Address Database. Due to the large size of the LAD database and the limited memory within the Agent, the cache is loaded into the cache memory buffer only when it is requested via this MIB variable. Setting this var to loadCache commands the agent to upload the LAD from the device exactly one time. Note that the contents of this cache are NOT automatically refreshed. Setting this variable to 'release' causes the data in the cache to be purged, even if the cache buffer contains data of an entirely different type, such as the VLAN table cache. Thus, it is not necessary to know what type of data was most recently loaded into the cache buffer, but it is necessary to take care not to release data that is currently in use. A genErr will be returned if any other command involving reading or writing the LAD or the VLAN table is in progress. " ::= { cmefg100Entry 55 } cmefg100LadCacheState OBJECT-TYPE SYNTAX INTEGER { ready(1), empty(2), transferring(3), bufferBusy(4), stale(5) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable shows the current state of the Agent's cache buffer with respect to the Learned Address Database. A value of 'ready' means that the cache buffer contains a complete copy of the LAD that is less than 300 seconds old. A value of 'stale' means that the cache buffer contains a complete copy of the LAD that is more than 300 seconds old. A value of 'empty' means that the buffer has been purged, and the system is ready to accept a cmefg100LadCacheCmd of 'loadCache.' A value of 'transferring' means that no command can be issued and the cache cannot be read because data is currently being transferred into the cache buffer. The data may or may not be related to the LAD. A value of 'bufferBusy' means that the buffer contains a complete copy (ready or stale) of something other than the LAD. The contents of the buffer can be overwritten with the LAD by issuing a 'loadCache' command. " ::= { cmefg100Entry 56 } cmefg100LadEditCmd OBJECT-TYPE SYNTAX INTEGER { write(1), delete(2), doNothing(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this var to 'write' causes LadEditMac, LadEditPort, and LadEditVid to be written (insert/overwrite as required) to the LAD. Setting this var to 'delete' causes the address represented by LadEditMac to be deleted from the LAD. Changes made are not reflected in the LAD cache until the device accepts them and the cache is reloaded. A genErr will be returned if any other command involving reading or writing the LAD or the VLAN table is in progress. " ::= { cmefg100Entry 57 } cmefg100LadEditMac OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "A plain-text representation of a MAC address to be used the next time cmefg100LadEditCmd is set to write or delete. " ::= { cmefg100Entry 58 } cmefg100LadEditPort OBJECT-TYPE SYNTAX INTEGER { twistedPair(1), fiber(2), drop(3) } ACCESS read-write STATUS mandatory DESCRIPTION "A port to be used the next time cmefg100LadEditCmd is set to write. " ::= { cmefg100Entry 59 } cmefg100LadEditVid OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A VLAN Id to be used the next time cmefg100LadEditCmd is set to write. Not valid when cmefg100VlanEnable is disabled(2) " ::= { cmefg100Entry 60 } cmefg100LadEntries OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A count of the number of entries currently in the LAD Cache. See also cmefg100LadCacheState. If a LAD cache-filling transfer is in progress, this variable can be read for a progress report. " ::= { cmefg100Entry 61 } cmefg100LadMacTbl OBJECT-TYPE SYNTAX MacAddress ACCESS read-only STATUS mandatory DESCRIPTION "An Ethernet MAC address in the LAD table. The SubDeviceIndex is an arbitrary integer sequence number, range 1..cmefg100LadEntries. If cmefg100LadEntries is 0 (either because cmefg100LadCacheState is not 'ready/stale' or because there simply are no entries), this table contains a solitary dummy entry, SubDeviceIndex==1. " ::= { cmefg100Entry 62 } cmefg100LadPortTbl OBJECT-TYPE SYNTAX INTEGER { twistedPair(1), fiber(2), drop(3), notApplicable(4) } ACCESS read-only STATUS mandatory DESCRIPTION "A port in the LAD table. Drop means 'forward to neither port' The SubDeviceIndex is an arbitrary integer sequence number, range 1..cmefg100LadEntries. If cmefg100LadEntries is 0 (either because cmefg100LadCacheState is not 'ready/stale' or because there simply are no entries), this table contains a solitary entry, SubDeviceIndex==1, value notApplicable. " ::= { cmefg100Entry 63 } cmefg100LadStaticTbl OBJECT-TYPE SYNTAX INTEGER { static(1), dynamic(2), notApplicable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "An indication of whether the indexed entry in the LAD is static or dynamic. The SubDeviceIndex is an arbitrary integer sequence number, range 1..cmefg100LadEntries. If cmefg100LadEntries is 0 (either because cmefg100LadCacheState is not 'ready/stale' or because there simply are no entries), this table contains a solitary entry, SubDeviceIndex==1, value notApplicable. " ::= { cmefg100Entry 64 } cmefg100LadVidTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A VLAN Id in the LAD table. The SubDeviceIndex is an arbitrary integer sequence number, range 1..cmefg100LadEntries. If cmefg100LadEntries is 0 (either because cmefg100LadCacheState is not 'ready/stale' or because there simply are no entries), this table contains a solitary dummy entry, SubDeviceIndex==1. Always returns the dummy value '0' when cmefg100VlanEnable is disabled(2). " ::= { cmefg100Entry 65 } cmefg100LocColdstart OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 66 } cmefg100LocDmiRxPower OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "DMI: Diagnostic Monitoring Interface for fiber transceivers " ::= { cmefg100Entry 67 } cmefg100LocDmiRxPowerAlarm OBJECT-TYPE SYNTAX INTEGER { normal(1), notSupported(2), lowWarn(3), highWarn(4), lowAlarm(5), highAlarm(6) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 68 } cmefg100LocDmiTemp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "In tenths of degrees C " ::= { cmefg100Entry 69 } cmefg100LocDmiTempAlarm OBJECT-TYPE SYNTAX INTEGER { normal(1), notSupported(2), lowWarn(3), highWarn(4), lowAlarm(5), highAlarm(6) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 70 } cmefg100LocDmiTxBiasAlarm OBJECT-TYPE SYNTAX INTEGER { normal(1), notSupported(2), lowWarn(3), highWarn(4), lowAlarm(5), highAlarm(6) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 71 } cmefg100LocDmiTxBiasCurrent OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "In microamperes " ::= { cmefg100Entry 72 } cmefg100LocDmiTxPower OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "In microwatts " ::= { cmefg100Entry 73 } cmefg100LocDmiTxPowerAlarm OBJECT-TYPE SYNTAX INTEGER { normal(1), notSupported(2), lowWarn(3), highWarn(4), lowAlarm(5), highAlarm(6) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 74 } cmefg100LocFiberAdv1000FDX OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notApplicable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Read-only value notApplicable returned when autonegotiation is disabled " ::= { cmefg100Entry 75 } cmefg100LocFiberAdv1000HDX OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notApplicable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Read-only value notApplicable returned when autonegotiation is disabled " ::= { cmefg100Entry 76 } cmefg100LocFiberAutoNegot OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 77 } cmefg100LocFiberConnA OBJECT-TYPE SYNTAX CpsConnector ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 78 } cmefg100LocFiberDuplex OBJECT-TYPE SYNTAX INTEGER { forceFDX(1), forceHDX(2), autoFDX(3), autoHDX(4), negotiating(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Read-only values 3..5 are returned when autonegotiation is enabled " ::= { cmefg100Entry 79 } cmefg100LocFiberLink OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 80 } cmefg100LocFiberPause OBJECT-TYPE SYNTAX INTEGER { asymmetricRx(1), asymmetricTx(2), symmetric(3), disabled(4) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 81 } cmefg100LocFiberQosPause OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 82 } cmefg100LocFiberSacEnable OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/disable traps for Source Address Change " ::= { cmefg100Entry 83 } cmefg100LocFiberSacStatus OBJECT-TYPE SYNTAX INTEGER { changed(1), constant(2) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 84 } cmefg100LocFirmwareRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 85 } cmefg100LocFpgaRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Field-Programmable Gate Array revision " ::= { cmefg100Entry 86 } cmefg100LocFxTxBwaKb OBJECT-TYPE SYNTAX INTEGER (1..122112) ACCESS read-write STATUS mandatory DESCRIPTION "FX to TX bandwidth allocation, in Kbps " ::= { cmefg100Entry 87 } cmefg100LocFxTxBwaMb OBJECT-TYPE SYNTAX INTEGER (1..1000) ACCESS read-write STATUS mandatory DESCRIPTION "FX to TX bandwidth allocation, in Mbps " ::= { cmefg100Entry 88 } cmefg100LocOamActiveMode OBJECT-TYPE SYNTAX INTEGER { active(1), passive(2) } ACCESS read-only STATUS mandatory DESCRIPTION "OAM: Operation, Administration, and Maintenance " ::= { cmefg100Entry 89 } cmefg100LocOamAdminControl OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 90 } cmefg100LocOamConfigRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 91 } cmefg100LocOamControlInUnknownOpcodes OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 92 } cmefg100LocOamCriticalEvent OBJECT-TYPE SYNTAX INTEGER { critical(1), normal(2) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 93 } cmefg100LocOamDuplicateEventNotificationRx OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 94 } cmefg100LocOamFramesLostDueToOamError OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 95 } cmefg100LocOamInformationRx OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 96 } cmefg100LocOamInformationTx OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 97 } cmefg100LocOamLastGasp OBJECT-TYPE SYNTAX INTEGER { failure(1), normal(2) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 98 } cmefg100LocOamLinkEvents OBJECT-TYPE SYNTAX INTEGER { supported(1), notSupported(2) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 99 } cmefg100LocOamLinkFault OBJECT-TYPE SYNTAX INTEGER { fault(1), normal(2) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 100 } cmefg100LocOamLocDteDisc OBJECT-TYPE SYNTAX INTEGER { completed(1), notCompleted(2), unsatisfied(3) } ACCESS read-only STATUS mandatory DESCRIPTION "discovery state " ::= { cmefg100Entry 101 } cmefg100LocOamLoopbackControlRx OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 102 } cmefg100LocOamLoopbackControlTx OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 103 } cmefg100LocOamMacAddress OBJECT-TYPE SYNTAX MacAddress ACCESS read-only STATUS mandatory DESCRIPTION "The MAC address of the OAM entity. " ::= { cmefg100Entry 104 } cmefg100LocOamMaxOamPduSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 105 } cmefg100LocOamMultiplexorState OBJECT-TYPE SYNTAX INTEGER { forwarding(1), discarding(2) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 106 } cmefg100LocOamOperStatus OBJECT-TYPE SYNTAX INTEGER { linkFault(1), activeSendLocal(2), passiveWait(3), sendLocalRemote(4), sendLocalRemoteOk(5), sendAny(6) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 107 } cmefg100LocOamOrgSpecificRx OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 108 } cmefg100LocOamOrgSpecificTx OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 109 } cmefg100LocOamParserState OBJECT-TYPE SYNTAX INTEGER { forwarding(1), discarding(2), looping(3) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 110 } cmefg100LocOamRmtDteDisc OBJECT-TYPE SYNTAX INTEGER { completed(1), notCompleted(2), unsatisfied(3) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 111 } cmefg100LocOamRmtLoopback OBJECT-TYPE SYNTAX INTEGER { supported(1), notSupported(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether or not local has support to allow remote to initiate remote loopback mode. " ::= { cmefg100Entry 112 } cmefg100LocOamUnidirectional OBJECT-TYPE SYNTAX INTEGER { supported(1), notSupported(2) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 113 } cmefg100LocOamVarRetrieval OBJECT-TYPE SYNTAX INTEGER { supported(1), notSupported(2) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 114 } cmefg100LocSelfTestFailed OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 115 } cmefg100LocSerialNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 116 } cmefg100LocTpAdv1000FDX OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notApplicable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Read-only value notApplicable returned when autonegotiation is disabled " ::= { cmefg100Entry 117 } cmefg100LocTpAdv1000HDX OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notApplicable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Read-only value notApplicable returned when autonegotiation is disabled " ::= { cmefg100Entry 118 } cmefg100LocTpAdv100FDX OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notApplicable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Read-only value notApplicable returned when autonegotiation is disabled " ::= { cmefg100Entry 119 } cmefg100LocTpAdv100HDX OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notApplicable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Read-only value notApplicable returned when autonegotiation is disabled " ::= { cmefg100Entry 120 } cmefg100LocTpAdv10FDX OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notApplicable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Read-only value notApplicable returned when autonegotiation is disabled " ::= { cmefg100Entry 121 } cmefg100LocTpAdv10HDX OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notApplicable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Read-only value notApplicable returned when autonegotiation is disabled " ::= { cmefg100Entry 122 } cmefg100LocTpAutoNegot OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 123 } cmefg100LocTpConnB OBJECT-TYPE SYNTAX CpsConnector ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 124 } cmefg100LocTpCross OBJECT-TYPE SYNTAX INTEGER { forceMDI(1), forceMDI-X(2), auto(3) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 125 } cmefg100LocTpDuplex OBJECT-TYPE SYNTAX INTEGER { forceFDX(1), forceHDX(2), autoFDX(3), autoHDX(4), negotiating(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Read-only values 3..5 are returned when autonegotiation is enabled " ::= { cmefg100Entry 126 } cmefg100LocTpLink OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 127 } cmefg100LocTpPause OBJECT-TYPE SYNTAX INTEGER { asymmetricRx(1), asymmetricTx(2), symmetric(3), disabled(4) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 128 } cmefg100LocTpQosPause OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "QOS: Quality of Service " ::= { cmefg100Entry 129 } cmefg100LocTpSacEnable OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/disable traps for Source Address Change " ::= { cmefg100Entry 130 } cmefg100LocTpSacStatus OBJECT-TYPE SYNTAX INTEGER { changed(1), constant(2) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 131 } cmefg100LocTpSpeed OBJECT-TYPE SYNTAX INTEGER { force10Mbps(1), force100Mbps(2), auto10Mbps(3), auto100Mbps(4), auto1000Mbps(5), negotiating(6) } ACCESS read-write STATUS mandatory DESCRIPTION "Read-only values 3..6 are returned when autonegotiation is enabled " ::= { cmefg100Entry 132 } cmefg100LocTxFxBwaKb OBJECT-TYPE SYNTAX INTEGER (1..122112) ACCESS read-write STATUS mandatory DESCRIPTION "TX to FX bandwidth allocation, in Kbps " ::= { cmefg100Entry 133 } cmefg100LocTxFxBwaMb OBJECT-TYPE SYNTAX INTEGER (1..1000) ACCESS read-write STATUS mandatory DESCRIPTION "TX to FX bandwidth allocation, in Mbps " ::= { cmefg100Entry 134 } cmefg100LocUptime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-write STATUS mandatory DESCRIPTION "Write with 0 to reset. " ::= { cmefg100Entry 135 } cmefg100QosHqWeight OBJECT-TYPE SYNTAX INTEGER (0..15) ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 136 } cmefg100QosLqWeight OBJECT-TYPE SYNTAX INTEGER (0..15) ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 137 } cmefg100QosPriority OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 138 } cmefg100RmtColdStart OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 139 } cmefg100RmtDetected OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 140 } cmefg100RmtDmiRxPower OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 141 } cmefg100RmtDmiRxPowerAlarm OBJECT-TYPE SYNTAX INTEGER { normal(1), notSupported(2), lowWarn(3), highWarn(4), lowAlarm(5), highAlarm(6) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 142 } cmefg100RmtDmiTemp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "In tenths of degrees C " ::= { cmefg100Entry 143 } cmefg100RmtDmiTempAlarm OBJECT-TYPE SYNTAX INTEGER { normal(1), notSupported(2), lowWarn(3), highWarn(4), lowAlarm(5), highAlarm(6) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 144 } cmefg100RmtDmiTxBiasAlarm OBJECT-TYPE SYNTAX INTEGER { normal(1), notSupported(2), lowWarn(3), highWarn(4), lowAlarm(5), highAlarm(6) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 145 } cmefg100RmtDmiTxBiasCurrent OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "In microamperes " ::= { cmefg100Entry 146 } cmefg100RmtDmiTxPower OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "In microwatts " ::= { cmefg100Entry 147 } cmefg100RmtDmiTxPowerAlarm OBJECT-TYPE SYNTAX INTEGER { normal(1), notSupported(2), lowWarn(3), highWarn(4), lowAlarm(5), highAlarm(6) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 148 } cmefg100RmtFactoryReset OBJECT-TYPE SYNTAX INTEGER { reset(1), doNothing(2) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 149 } cmefg100RmtFiberAutoNegot OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 150 } cmefg100RmtFiberLink OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 151 } cmefg100RmtFiberPause OBJECT-TYPE SYNTAX INTEGER { asymmetricRx(1), asymmetricTx(2), symmetric(3), notSupported(4) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 152 } cmefg100RmtFiberQosPause OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 153 } cmefg100RmtFirmwareRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 154 } cmefg100RmtFpgaRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Field-Programmable Gate Array revision " ::= { cmefg100Entry 155 } cmefg100RmtOamActiveMode OBJECT-TYPE SYNTAX INTEGER { active(1), passive(2) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 156 } cmefg100RmtOamCriticalEvent OBJECT-TYPE SYNTAX INTEGER { critical(1), normal(2) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 157 } cmefg100RmtOamLastGasp OBJECT-TYPE SYNTAX INTEGER { failure(1), normal(2) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 158 } cmefg100RmtOamLinkEvents OBJECT-TYPE SYNTAX INTEGER { supported(1), notSupported(2) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 159 } cmefg100RmtOamLinkFault OBJECT-TYPE SYNTAX INTEGER { fault(1), normal(2) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 160 } cmefg100RmtOamLocDteDisc OBJECT-TYPE SYNTAX INTEGER { completed(1), notCompleted(2), unsatisfied(3) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 161 } cmefg100RmtOamPeerConfigRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 162 } cmefg100RmtOamPeerMacAddress OBJECT-TYPE SYNTAX MacAddress ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 163 } cmefg100RmtOamPeerMaxOamPduSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 164 } cmefg100RmtOamPeerMultiplexorState OBJECT-TYPE SYNTAX INTEGER { forwarding(1), discarding(2) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 165 } cmefg100RmtOamPeerParserState OBJECT-TYPE SYNTAX INTEGER { forwarding(1), discarding(2), looping(3) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 166 } cmefg100RmtOamPeerVendorInfo OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 167 } cmefg100RmtOamPeerVendorOui OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 168 } cmefg100RmtOamRmtDteDisc OBJECT-TYPE SYNTAX INTEGER { completed(1), notCompleted(2), unsatisfied(3) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 169 } cmefg100RmtOamRmtLoopback OBJECT-TYPE SYNTAX INTEGER { enabledOam(1), enabledAlternate(2), disabled(3), notSupported(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Initiates remote loopback mode if the remote supports it. See RmtOamPeerParserState for status information " ::= { cmefg100Entry 170 } cmefg100RmtOamUnidirectional OBJECT-TYPE SYNTAX INTEGER { supported(1), notSupported(2) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 171 } cmefg100RmtOamVarRetrieval OBJECT-TYPE SYNTAX INTEGER { supported(1), notSupported(2) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 172 } cmefg100RmtSelfTestFailed OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 173 } cmefg100RmtSerialNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 174 } cmefg100RmtTpAdv1000FDX OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notApplicable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Read-only value notApplicable returned when autonegotiation is disabled " ::= { cmefg100Entry 175 } cmefg100RmtTpAdv1000HDX OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notApplicable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Read-only value notApplicable returned when autonegotiation is disabled " ::= { cmefg100Entry 176 } cmefg100RmtTpAdv100FDX OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notApplicable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Read-only value notApplicable returned when autonegotiation is disabled " ::= { cmefg100Entry 177 } cmefg100RmtTpAdv100HDX OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notApplicable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Read-only value notApplicable returned when autonegotiation is disabled " ::= { cmefg100Entry 178 } cmefg100RmtTpAdv10FDX OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notApplicable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Read-only value notApplicable returned when autonegotiation is disabled " ::= { cmefg100Entry 179 } cmefg100RmtTpAdv10HDX OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notApplicable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Read-only value notApplicable returned when autonegotiation is disabled " ::= { cmefg100Entry 180 } cmefg100RmtTpAutoNegot OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 181 } cmefg100RmtTpCross OBJECT-TYPE SYNTAX INTEGER { forceMDI(1), forceMDI-X(2), auto(3) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 182 } cmefg100RmtTpDuplex OBJECT-TYPE SYNTAX INTEGER { forceFDX(1), forceHDX(2), autoFDX(3), autoHDX(4), negotiating(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Read-only values 3..5 are returned when autonegotiation is enabled " ::= { cmefg100Entry 183 } cmefg100RmtTpLink OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 184 } cmefg100RmtTpPause OBJECT-TYPE SYNTAX INTEGER { asymmetricRx(1), asymmetricTx(2), symmetric(3), notSupported(4) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 185 } cmefg100RmtTpQosPause OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 186 } cmefg100RmtTpSpeed OBJECT-TYPE SYNTAX INTEGER { force10Mbps(1), force100Mbps(2), auto10Mbps(3), auto100Mbps(4), auto1000Mbps(5), negotiating(6) } ACCESS read-write STATUS mandatory DESCRIPTION "Read-only values 3..6 are returned when autonegotiation is enabled " ::= { cmefg100Entry 187 } cmefg100RmtUptime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-write STATUS mandatory DESCRIPTION "Write with 0 to reset. " ::= { cmefg100Entry 188 } cmefg100VlanCacheCmd OBJECT-TYPE SYNTAX INTEGER { loadCache(1), doNothing(2), release(3) } ACCESS read-write STATUS mandatory DESCRIPTION "All variables starting with cmefg100Lad relate to 802.1Q VLAN controls. Setting this var to loadCache commands the agent to upload the VLAN table from the device exactly one time. Note that the contents of this cache are NOT automatically refreshed. A genErr will be returned if any other command involving reading or writing the LAD or the VLAN table is in progress. " ::= { cmefg100Entry 189 } cmefg100VlanCacheState OBJECT-TYPE SYNTAX INTEGER { ready(1), empty(2), transferring(3), bufferBusy(4) } ACCESS read-write STATUS mandatory DESCRIPTION "The agent discards the VLAN table shortly after uploading it to prevent the reporting of outdated information. This variable shows the current state of the cache. If it reads 'empty,' set VlanCacheCmd to loadCache to upload the VLAN table. " ::= { cmefg100Entry 190 } cmefg100VlanEditCmd OBJECT-TYPE SYNTAX INTEGER { write(1), delete(2), doNothing(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this var to write causes VlanEditFwdFiber, VlanEditFwdTp, VlanEditUntagFiber, VlanEditUntagTp, and VlanEditVid to be written to the VLAN tablei (i.e. insert/overwrite). Setting this var to delete causes the VLAN Id represented by VlanEditVlanId to be deleted from the VLAN table. A genErr will be returned if any other command involving reading or writing the LAD or the VLAN table is in progress. " ::= { cmefg100Entry 191 } cmefg100VlanEditFwdFiber OBJECT-TYPE SYNTAX INTEGER { drop(1), forward(2) } ACCESS read-only STATUS mandatory DESCRIPTION "A fiber egress rule to be acted upon by VlanEditCmd " ::= { cmefg100Entry 192 } cmefg100VlanEditFwdTp OBJECT-TYPE SYNTAX INTEGER { drop(1), forward(2) } ACCESS read-only STATUS mandatory DESCRIPTION "A twisted pair egress rule to be acted upon by VlanEditCmd " ::= { cmefg100Entry 193 } cmefg100VlanEditUntagFiber OBJECT-TYPE SYNTAX INTEGER { untag(1), asIs(2) } ACCESS read-only STATUS mandatory DESCRIPTION "A fiber untag rule to be acted upon by VlanEditCmd " ::= { cmefg100Entry 194 } cmefg100VlanEditUntagTp OBJECT-TYPE SYNTAX INTEGER { untag(1), asIs(2) } ACCESS read-only STATUS mandatory DESCRIPTION "A twisted pair untag rule to be acted upon by VlanEditCmd " ::= { cmefg100Entry 195 } cmefg100VlanEditVid OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A VLAN Id to be acted upon by VlanEditCmd " ::= { cmefg100Entry 196 } cmefg100VlanEnable OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/disable for 802.1Q VLAN tag processing. " ::= { cmefg100Entry 197 } cmefg100VlanEntries OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A count of the number of entries currently in the VLAN table cache. See also VlanCacheState. If a VLAN cache-filling transfer is in progress, this variable can be read for a progress report. " ::= { cmefg100Entry 198 } cmefg100VlanFiberDefaultPri OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 199 } cmefg100VlanFiberDefaultVid OBJECT-TYPE SYNTAX INTEGER (0..4095) ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 200 } cmefg100VlanFiberInUntaggedDrop OBJECT-TYPE SYNTAX INTEGER { drop(1), forward(2), notApplicable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 201 } cmefg100VlanFwdFiberTbl OBJECT-TYPE SYNTAX INTEGER { drop(1), forward(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether packets with the VLAN Id specified by the corresponding cmefg100VlanVidTbl entry (i.e. the one with the same SubDeviceIndex) are forwarded or dropped when they are routed for fiber egress. The SubDeviceIndex is an arbitrary integer sequence number, range 1..cmefg100VlanEntries. " ::= { cmefg100Entry 202 } cmefg100VlanFwdTpTbl OBJECT-TYPE SYNTAX INTEGER { drop(1), forward(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether packets with the VLAN Id specified by the corresponding cmefg100VlanVidTbl entry (i.e. the one with the same SubDeviceIndex) are forwarded or dropped when they are routed for twisted pair egress. The SubDeviceIndex is an arbitrary integer sequence number, range 1..cmefg100VlanEntries. " ::= { cmefg100Entry 203 } cmefg100VlanIngressVidHitNoMem OBJECT-TYPE SYNTAX INTEGER { forward(1), drop(2), learn(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Ingress violation - port from which frame originates is not a member of the VLAN indicated by the frame's tag " ::= { cmefg100Entry 204 } cmefg100VlanIngressVidMiss OBJECT-TYPE SYNTAX INTEGER { flood(1), drop(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Ingress violation - the VLAN indicated by the frame's tag is undefined in the VLAN table. " ::= { cmefg100Entry 205 } cmefg100VlanPriMapTbl OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-write STATUS mandatory DESCRIPTION "A table containing new priority values for priority remapping. The SubDeviceIndex is 'original priority', range 0..7. " ::= { cmefg100Entry 206 } cmefg100VlanPriTagCtrl OBJECT-TYPE SYNTAX INTEGER { asIs(1), remapPriority(2), remapVid(3), remapBoth(4), notApplicable(5) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 207 } cmefg100VlanSetFailed OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 208 } cmefg100VlanTagIn OBJECT-TYPE SYNTAX INTEGER { tag(1), noTag(2), notApplicable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 209 } cmefg100VlanTpDefaultPri OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 210 } cmefg100VlanTpDefaultVid OBJECT-TYPE SYNTAX INTEGER (0..4095) ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 211 } cmefg100VlanTpInUntaggedDrop OBJECT-TYPE SYNTAX INTEGER { drop(1), forward(2) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 212 } cmefg100VlanUntagFiberTbl OBJECT-TYPE SYNTAX INTEGER { untag(1), asIs(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether VLAN Ids are stripped from packets with the VLAN Id specified by the corresponding cmefg100VlanVidTbl entry (i.e. the one with the same SubDeviceIndex) when they are routed for fiber egress. The SubDeviceIndex is an arbitrary integer sequence number, range 1..cmefg100VlanEntries. " ::= { cmefg100Entry 213 } cmefg100VlanUntagTpTbl OBJECT-TYPE SYNTAX INTEGER { untag(1), asIs(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether VLAN Ids are stripped from packets with the VLAN Id specified by the corresponding cmefg100VlanVidTbl entry (i.e. the one with the same SubDeviceIndex) when they are routed for twisted pair egress. The SubDeviceIndex is an arbitrary integer sequence number, range 1..cmefg100VlanEntries. " ::= { cmefg100Entry 214 } cmefg100VlanVidTagCtrl OBJECT-TYPE SYNTAX INTEGER { asIs(1), remapPriority(2), remapVid(3), remapBoth(4), notApplicable(5) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { cmefg100Entry 215 } cmefg100VlanVidTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The SubDeviceIndex is an arbitrary integer sequence number, range 1..cmefg100VlanEntries. " ::= { cmefg100Entry 216 } cmefg100CacheClean OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "And all of the MIB variables lived happily ever after. The End. " ::= { cmefg100Entry 217 } -- ================================================================== -- MCC-16 MEDIA CONVERTER CHASSIS, a chassis containing 16 mc20p -- (20 pin media converter) slots. -- mcc16ComHwReset OBJECT-TYPE SYNTAX INTEGER { noReset(1), reset(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Save configuration to FLASH and perform a hardware reset" ::= { mcc16Common 1 } mcc16ComMgmtHwRev OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The management h/w board revision." ::= { mcc16Common 2 } mcc16ComMgmtSwRev OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The downloadable management s/w code revision." ::= { mcc16Common 3 } mcc16ComIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IP address of the management interface." ::= { mcc16Common 4 } mcc16ComNetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The subnet mask associated with the IP address of the management interface. The value of the mask is an IP address with all the network bits set to 1 and all the hosts bits set to 0." ::= { mcc16Common 5 } mcc16ComGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The managment interface's default gateway." ::= { mcc16Common 6 } mcc16ComPS1Power OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "On if power supply 1 is installed and powered" ::= { mcc16Common 7 } mcc16ComPS1InUse OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "On if power supply 1 is currently active" ::= { mcc16Common 8 } mcc16ComPS2Power OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "On if power supply 2 is installed and powered" ::= { mcc16Common 9 } mcc16ComPS2InUse OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "On if power supply 2 is currently active" ::= { mcc16Common 10 } mcc16ComNotes OBJECT-TYPE SYNTAX DisplayString (SIZE (0..4096)) ACCESS read-write STATUS mandatory DESCRIPTION "Enduser-defined text notes" ::= { mcc16Common 11 } -- =========================================================================== -- -- NOTE: The following datums have been deliberately omitted from this MIB: -- MCC16 MANAGEMENT MODULE POWER -- MCC16 MANAGEMENT MODULE ETHERNET LINK -- MCC16 MANAGEMENT MODULE ETHERNET TRANSMIT -- MCC16 MANAGEMENT MODULE ETHERNET RECEIVE -- This is due to the fact that if you receive any response at all from the -- management module, you may safely assume that all four of these items are -- 'on.' Any time one or more of these four conditions fails, the management -- module is obviously unable to report this fact to the NMS. Therefore, if -- these items *were* supported, they would *always* read 'on.' -- -- =========================================================================== -- The slot table contains one entry per slot. Each entry contains OID of -- the device that is contained in the slot. mcc16SlotTable OBJECT-TYPE SYNTAX SEQUENCE OF Mcc16SlotEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "One table entry per slot in the media converter chassis. Value of entry is type of device in the slot, or a value indicating that the slot is empty." ::= { mcc16Ver1 1 } mcc16SlotEntry OBJECT-TYPE SYNTAX Mcc16SlotEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The type of device inserted in a single chassis slot" INDEX { mcc16Index } ::= { mcc16SlotTable 1 } Mcc16SlotEntry ::= SEQUENCE { mcc16Index INTEGER, mcc16DeviceType OBJECT IDENTIFIER } mcc16Index OBJECT-TYPE SYNTAX INTEGER (1..16) ACCESS read-only STATUS mandatory DESCRIPTION "The index of a slot in a media converter chassis" ::= { mcc16SlotEntry 1 } mcc16DeviceType OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The object ID of the device in the a slot" ::= { mcc16SlotEntry 2 } -- -- MCC-16 specific traps. -- mcc16Error TRAP-TYPE ENTERPRISE chassisMcc16Id DESCRIPTION "A monitored MIB variable has changed from its 'operational' state to 'not present' or its 'error' state." ::= 101 mcc16ErrorClear TRAP-TYPE ENTERPRISE chassisMcc16Id DESCRIPTION "A monitored MIB variable has changed from a 'not present' or 'error' state to its 'operational' state." ::= 102 mcc16PSState TRAP-TYPE ENTERPRISE chassisMcc16Id DESCRIPTION "The power indication on a power supply has changed, or a power supply was non-operational at the time of a warm start." ::= 103 -- -- Point System specific traps. -- pSError TRAP-TYPE ENTERPRISE cpsmM100Id DESCRIPTION "A monitored MIB variable has changed from its 'operational' state to its 'error' state." ::= 111 pSErrorClear TRAP-TYPE ENTERPRISE cpsmM100Id DESCRIPTION "A monitored MIB variable has changed from its 'error' state to its 'operational' state." ::= 112 pSDeviceInserted TRAP-TYPE ENTERPRISE cpsmM100Id DESCRIPTION "A new slide-in device (this includes some power supplies) was detected on the bus." ::= 113 pSDeviceRemoved TRAP-TYPE ENTERPRISE cpsmM100Id DESCRIPTION "A slide-in device that had previously been detected on the bus has not been heard from in a long time, and is presumed to have been physically removed." ::= 114 pSDeviceColdStart TRAP-TYPE ENTERPRISE cpsmM100Id DESCRIPTION "A slide-in device has indicated that it has rebooted. This is most common when the device is inserted into its slot, but in a few cases this trap indicates a warm start." ::= 115 pSPowerLost TRAP-TYPE ENTERPRISE cpsmM100Id DESCRIPTION "The cabinet into which this management module is installed has lost power. Both the cabinet and the management module must support this feature for this trap to be sent." ::= 116 pSCabinetAdded TRAP-TYPE ENTERPRISE cpsmM100Id DESCRIPTION "A new cabinet was detected on the bus." ::= 117 pSCabinetRemoved TRAP-TYPE ENTERPRISE cpsmM100Id DESCRIPTION "A cabinet that had previously been detected on the bus has not been heard from in a long time, and is presumed to have been physically removed." ::= 118 -- ================================================================ -- Table of Cabinets in a Point System stack. cpsCabinetTable OBJECT-TYPE SYNTAX SEQUENCE OF CpsCabinetEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Sparse table containing one entry for each Cabinet in the stack, indexed by cabinet serial number." ::= { cpsCabSummary 1 } cpsCabinetEntry OBJECT-TYPE SYNTAX CpsCabinetEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Status and Configuration entries for a single Cabinet." INDEX { cpsCabinetBiaIndex } ::= { cpsCabinetTable 1 } CpsCabinetEntry ::= SEQUENCE { cpsCabinetBiaIndex INTEGER, cpsCabinetModel OBJECT IDENTIFIER, cpsCabinetDescription DisplayString, cpsCabinetSequence INTEGER } cpsCabinetBiaIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number (BIA) of the Cabinet" ::= { cpsCabinetEntry 1 } cpsCabinetModel OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The model number of the cabinet" ::= { cpsCabinetEntry 2 } cpsCabinetDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "User defined text description of the cabinet. This description is a mirror of the ones that can be found under cpsCabDetail." ::= { cpsCabinetEntry 3 } cpsCabinetSequence OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "An arbitrary sequence number assigned to the cabinet by the agent for the use of the Focal Point application. Cabinets are sorted by BiaIndex in the table, and numbered sequentially." ::= { cpsCabinetEntry 4 } -- ================================================================ -- Cabinet detail table for CPSMC1800 18 slot Point System cabinet cpsMc1800Table OBJECT-TYPE SYNTAX SEQUENCE OF CpsMc1800Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Sparse table containing one entry for each CPSMC1800 in the stack, indexed by cabinet serial number." ::= { cpsCabDetail 1 } cpsMc1800Entry OBJECT-TYPE SYNTAX CpsMc1800Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Status and configuration entries for a single CPSMC1800" INDEX { cpsMc1800BiaIndex } ::= { cpsMc1800Table 1 } CpsMc1800Entry ::= SEQUENCE { cpsMc1800BiaIndex INTEGER, cpsMc1800Description DisplayString, cpsMc1800PSPower1 INTEGER, cpsMc1800PSInUse1 INTEGER, cpsMc1800PSPower2 INTEGER, cpsMc1800PSInUse2 INTEGER, cpsMc1800MRevision INTEGER } cpsMc1800BiaIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number (BIA) of the cabinet" ::= { cpsMc1800Entry 1 } cpsMc1800Description OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "User defined text description of the cabinet. A mirror of cpsCabinetDescription." ::= { cpsMc1800Entry 2 } cpsMc1800PSPower1 OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Power status, first power supply slot. Value is on(1) when the supply is capable of supplying power." ::= { cpsMc1800Entry 3 } cpsMc1800PSInUse1 OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Power status, first power supply slot. Value is yes(1) when the power is selected to supply power to the cabinet" ::= { cpsMc1800Entry 4 } cpsMc1800PSPower2 OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Power status, second power supply slot. Value is on(1) when the supply is capable of supplying power." ::= { cpsMc1800Entry 5 } cpsMc1800PSInUse2 OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Power status, second power supply slot. Value is yes(1) when the power is selected to supply power to the cabinet" ::= { cpsMc1800Entry 6 } cpsMc1800MRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The marketing revision of this device" ::= { cpsMc1800Entry 7 } -- ================================================================ -- Cabinet detail table for CPSMC1300 13 slot Point System cabinet cpsMc1300Table OBJECT-TYPE SYNTAX SEQUENCE OF CpsMc1300Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Sparse table containing one entry for each CPSMC1300 in the stack, indexed by cabinet serial number." ::= { cpsCabDetail 2 } cpsMc1300Entry OBJECT-TYPE SYNTAX CpsMc1300Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Status and configuration entries for a single CPSMC1300" INDEX { cpsMc1300BiaIndex } ::= { cpsMc1300Table 1 } CpsMc1300Entry ::= SEQUENCE { cpsMc1300BiaIndex INTEGER, cpsMc1300Description DisplayString, cpsMc1300PSPower1 INTEGER, cpsMc1300PSInUse1 INTEGER, cpsMc1300PSPower2 INTEGER, cpsMc1300PSInUse2 INTEGER, cpsMc1300MRevision INTEGER } cpsMc1300BiaIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number (BIA) of the cabinet" ::= { cpsMc1300Entry 1 } cpsMc1300Description OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "User defined text description of the cabinet. A mirror of cpsCabinetDescription." ::= { cpsMc1300Entry 2 } cpsMc1300PSPower1 OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Power status, first power supply slot. Value is on(1) when the supply is capable of supplying power." ::= { cpsMc1300Entry 3 } cpsMc1300PSInUse1 OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "For future expansion. At the time of this writing, the CPSMC1300 did not accept any power supplies capable of supporting a master/slave relationship, meaning that all 'ready' power supplies share load and therefore are 'in use'. If master/slave support were present, inuse would indicate whether or not this supply was currently supplying power to the cabinet." ::= { cpsMc1300Entry 4 } cpsMc1300PSPower2 OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Power status, second power supply slot. Value is on(1) when the supply is capable of supplying power." ::= { cpsMc1300Entry 5 } cpsMc1300PSInUse2 OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "For future expansion. At the time of this writing, the CPSMC1300 did not accept any power supplies capable of supporting a master/slave relationship, meaning that all 'ready' power supplies share load and therefore are 'in use'. If master/slave support were present, inuse would indicate whether or not this supply was currently supplying power to the cabinet." ::= { cpsMc1300Entry 6 } cpsMc1300MRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The marketing revision of this device" ::= { cpsMc1300Entry 7 } -- ================================================================ -- Cabinet detail table for CPSMC0200 2 slot Point System cabinet cpsMc0200Table OBJECT-TYPE SYNTAX SEQUENCE OF CpsMc0200Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Sparse table containing one entry for each CPSMC0200 in the stack, indexed by cabinet serial number." ::= { cpsCabDetail 3 } cpsMc0200Entry OBJECT-TYPE SYNTAX CpsMc0200Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Status and configuration entries for a single CPSMC0200" INDEX { cpsMc0200BiaIndex } ::= { cpsMc0200Table 1 } CpsMc0200Entry ::= SEQUENCE { cpsMc0200BiaIndex INTEGER, cpsMc0200Description DisplayString, cpsMc0200MRevision INTEGER } cpsMc0200BiaIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number (BIA) of the cabinet" ::= { cpsMc0200Entry 1 } cpsMc0200Description OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "User defined text description of the cabinet. A mirror of cpsCabinetDescription." ::= { cpsMc0200Entry 2 } cpsMc0200MRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The marketing revision of this device" ::= { cpsMc0200Entry 3 } -- ================================================================ -- Cabinet detail table for CPSMC1900 19 slot Point System cabinet cpsMc1900Table OBJECT-TYPE SYNTAX SEQUENCE OF CpsMc1900Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Sparse table containing one entry for each CPSMC1900 in the stack, indexed by cabinet serial number." ::= { cpsCabDetail 4 } cpsMc1900Entry OBJECT-TYPE SYNTAX CpsMc1900Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Status and configuration entries for a single CPSMC1900" INDEX { cpsMc1900BiaIndex } ::= { cpsMc1900Table 1 } CpsMc1900Entry ::= SEQUENCE { cpsMc1900BiaIndex INTEGER, cpsMc1900Description DisplayString, cpsMc1900MRevision INTEGER } cpsMc1900BiaIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number (BIA) of the cabinet" ::= { cpsMc1900Entry 1 } cpsMc1900Description OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "User defined text description of the cabinet. A mirror of cpsCabinetDescription." ::= { cpsMc1900Entry 2 } cpsMc1900MRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The marketing revision of this device" ::= { cpsMc1900Entry 3 } -- ================================================================ -- Cabinet detail table for CPSMC0200 2 slot Point System cabinet smacf100Table OBJECT-TYPE SYNTAX SEQUENCE OF Smacf100Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Sparse table containing one entry for each SMACF100 in the stack, indexed by cabinet serial number." ::= { cpsCabDetail 5} smacf100Entry OBJECT-TYPE SYNTAX Smacf100Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Status and configuration entries for a single SMACF100" INDEX { smacf100BiaIndex } ::= { smacf100Table 1 } Smacf100Entry ::= SEQUENCE { smacf100BiaIndex INTEGER, smacf100Description DisplayString, smacf100MRevision INTEGER, smacf100SpanningTree INTEGER, smacf100ResetCounters INTEGER, smacf100SelfTest INTEGER, smacf100QosEnable INTEGER, smacf100QosHPThreshold INTEGER, smacf100QosLqWeight INTEGER, smacf100QosHqWeight INTEGER, smacf100SNMPModuleInstalled INTEGER, smacf100AgingTimer INTEGER } smacf100BiaIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number (BIA) of the cabinet" ::= { smacf100Entry 1 } smacf100Description OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "User defined text description of the cabinet. A mirror of cpsCabinetDescription." ::= { smacf100Entry 2 } smacf100MRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The marketing revision of this device" ::= { smacf100Entry 3 } smacf100SpanningTree OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notSupported(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows the agent to enable or disable Spanning Tree if it is supported. Not all versions of the hardware support Spanning Tree." ::= { smacf100Entry 4 } smacf100ResetCounters OBJECT-TYPE SYNTAX INTEGER { reset(1), doNothing(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When this variable is set to reset(1), all counters for all ports are reset to zero." ::= { smacf100Entry 5 } smacf100SelfTest OBJECT-TYPE SYNTAX INTEGER { selfTest(1), doNothing(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When this variable is set to selfTest(1), the cabinet will perform a self test." ::= { smacf100Entry 6 } smacf100QosEnable OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), notSupported(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable allows Quality of Service functions to be enabled or disabled. This includes the processing of 802.1p tags (See smacf100QosHPThreshold(8), smacf100QosLqWeight(9), and smacf100QosHqWeight(10)), half-duplex back pressure and full-duplex flow control. (See smacf100PQosPause(63)). Port priority functionality (smacf100PQosPriority(62)) is always enabled." ::= { smacf100Entry 7 } smacf100QosHPThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "When an incoming 802.1p priority tag value is greater than or equal to this value (from 0 to 7), the incoming packet will be classified as high-priority. Ignored when smacf100QosEnable(7) is set to 'disabled(2)'." ::= { smacf100Entry 8 } smacf100QosLqWeight OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A value between 1 and 15 indicating the number of packets that should be processed from the low-priority queue before attention is turned to the high-priority queue. Ignored when smacf100QosEnable(7) is set to 'disabled(2)'." ::= { smacf100Entry 9 } smacf100QosHqWeight OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A value between 1 and 15 indicating the number of packets that should be processed from the high-priority queue before attention is turned to the low-priority queue. Ignored when smacf100QosEnable(7) is set to 'disabled(2)'." ::= { smacf100Entry 10 } smacf100SNMPModuleInstalled OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "When this variable is set to yes(1), a management module is installed in this particular SMACF100 cabinet." ::= { smacf100Entry 11 } smacf100AgingTimer OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This configuration varible allows the MAC address aging timer to be adjusted. When an automatically discovered MAC address has not been heard from (i.e. no packets with this source address have been received) for longer than the time specified by this variable, it is deleted from the SMACF100's address cache. The time is specified in seconds (up to 1,048,575). If smacf100AgingTimer(12) is set to 0, MAC address aging is disabled." ::= { smacf100Entry 12 } -- ================================================================ -- Cabinet detail table for CPSMC0800 8 slot Point System cabinet cpsMc0800Table OBJECT-TYPE SYNTAX SEQUENCE OF CpsMc0800Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Sparse table containing one entry for each CPSMC0800 in the stack, indexed by cabinet serial number." ::= { cpsCabDetail 6 } cpsMc0800Entry OBJECT-TYPE SYNTAX CpsMc0800Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Status and configuration entries for a single CPSMC0800" INDEX { cpsMc0800BiaIndex } ::= { cpsMc0800Table 1 } CpsMc0800Entry ::= SEQUENCE { cpsMc0800BiaIndex INTEGER, cpsMc0800Description DisplayString, cpsMc0800MRevision INTEGER } cpsMc0800BiaIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number (BIA) of the cabinet" ::= { cpsMc0800Entry 1 } cpsMc0800Description OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "User defined text description of the cabinet. A mirror of cpsCabinetDescription." ::= { cpsMc0800Entry 2 } cpsMc0800MRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The marketing revision of this device" ::= { cpsMc0800Entry 3 } -- ================================================================== -- Group Control String for Point System cpsGroupCtrl OBJECT-TYPE SYNTAX DisplayString (SIZE (0..256)) ACCESS read-write STATUS mandatory DESCRIPTION "This string is used to select one or more groups of devices to receive mass configuration operations. When cpsGroupCtrl.0 is null, SNMP operations are performed in the standard way for SNMPv1. When cpsGroupCtrl.0 is not null, the Cabinet (BiaIndex) and Slot (SlotIndex) index values that uniquely identify a device are ignored, and instead the operation is applied to all devices that have Groups variables that contain user- or system-defined keywords that match those in cpsGroupCtrl.0. The CfgMatch variables (cpsSlotDetail) for each of these devices will be yes(1). Advanced options are invoked by prepending one of the following command characters to the keywords in cpsGroupCtrl.0: 1) '.' means 'Pick-One'. When any 'Pick-One' operators are present in the Group Control String, then one or more of the keywords so marked must appear in the Device Group String of the slide-in device for configuration changes to be allowed. 'Pick-One' is the default operation that is used when no command character is present on a keyword. 2) '-' or '!' means 'Prohibited'. When any 'Prohibited' operators are present in the Group Control String, then if any of the keywords so marked appears in the Device Group String of the slide-in device, then no configuration changes are applied. 3) '+' is the 'Required' operator. When any 'Required' operators are present in the Group Control String, then all of the keywords so marked must appear in the Device Group String of the slide-in device for configuration changes to be allowed. 4) '*' is a Wildcard that matches zero or more characters. It is the only command character that does not need to appear at the beginning of the keyword. It is also the only one that can be used in combination with the others within a single keyword." ::= { cpsAgent 1 } -- ===================================== cpsSlotPwrTable OBJECT-TYPE SYNTAX SEQUENCE OF CpsSlotPwrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Sparse table containing one power control entry for each slot in the stack, indexed by cabinet serial number and slot." ::= { cpsAgent 2 } cpsSlotPwrEntry OBJECT-TYPE SYNTAX CpsSlotPwrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The power on/off control for a single Point System slot." INDEX { cpsSlotPwrBiaIndex, cpsSlotPwrSlotIndex } ::= { cpsSlotPwrTable 1 } CpsSlotPwrEntry ::= SEQUENCE { cpsSlotPwrBiaIndex INTEGER, cpsSlotPwrSlotIndex INTEGER, cpsSlotPwrState INTEGER } cpsSlotPwrBiaIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The cabinet serial number (BIA) of the slot" ::= { cpsSlotPwrEntry 1 } cpsSlotPwrSlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The slot number of the slot" ::= { cpsSlotPwrEntry 2 } cpsSlotPwrState OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The power control for the slot. When off(2), no power is supplied to the slot. If examined, the slot will appear empty." ::= { cpsSlotPwrEntry 3 } -- ===================================== cpsIsPrimary OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates whether or not this Management Module is the primary Management Module in the stack. This variable contains the same information as the cpsmm100IsPrimary variable, but answers a slightly different question: cpsmm100IsPrimary answers 'what is the primary status of the management module in cabinet C slot S?' and cpsIsPrimary answers 'what is the primary status of the management module I am talking to now?' The difference is that cpsIsPrimary does not require that the requestor translate the IP address of the management module they are communicating with into a cabinet serial number (BIA) and slot index. This could otherwise only be accomplished via a sequential search through cpsmm100Table" ::= { cpsAgent 3 } END