-- Version 2.15.1.1, modified 2001-05-31 17:28:56-04 TR-OPT-MIB DEFINITIONS ::= BEGIN IMPORTS Counter, enterprises FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212; -- Codex MIB Group definitions codex OBJECT IDENTIFIER ::= { enterprises 449 } cdxProductSpecific OBJECT IDENTIFIER ::= { codex 2 } cdx6500 OBJECT IDENTIFIER ::= { cdxProductSpecific 1 } cdx6500Configuration OBJECT IDENTIFIER ::= { cdx6500 2 } cdx6500CfgProtocolGroup OBJECT IDENTIFIER ::= { cdx6500Configuration 1 } cdx6500PCTPortProtocolGroup OBJECT IDENTIFIER ::= { cdx6500CfgProtocolGroup 1 } cdx6500Statistics OBJECT IDENTIFIER ::= { cdx6500 3 } cdx6500StatProtocolGroup OBJECT IDENTIFIER ::= { cdx6500Statistics 1 } cdx6500PSTPortProtocolGroup OBJECT IDENTIFIER ::= { cdx6500StatProtocolGroup 1 } cdx6500Controls OBJECT IDENTIFIER ::= { cdx6500 4 } -- Textual conventions MacAddress ::= OCTET STRING (SIZE (6)) DisplayString ::= OCTET STRING -- The Dot5 Configuration Table -- This table contains configuration information in addition -- to that included in RFC1321. cdx6500PPCTdot5PortTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500PPCTdot5PortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains Token Ring interface parameters and state variables, one entry per 802.5 interface." ::= { cdx6500PCTPortProtocolGroup 9 } cdx6500PPCTdot5PortEntry OBJECT-TYPE SYNTAX Cdx6500PPCTdot5PortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of Token Ring status and parameter values for an 802.5 interface." INDEX { cdx6500dot5IfIndex } ::= { cdx6500PPCTdot5PortTable 1 } Cdx6500PPCTdot5PortEntry ::= SEQUENCE { cdx6500dot5IfIndex INTEGER, cdx6500dot5LanCableType INTEGER, cdx6500dot5PortMacAddress MacAddress, cdx6500dot5LocalRingNumber INTEGER, cdx6500dot5EarlyTokenRelease INTEGER, cdx6500dot5TransmitQueueLimit INTEGER } cdx6500dot5IfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object is the port number for the LAN Interface." ::= { cdx6500PPCTdot5PortEntry 1 } cdx6500dot5LanCableType OBJECT-TYPE SYNTAX INTEGER { utp (0), stp (1), unknown (3), newvalUtp (50) } ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the type of cable and therefore which connector is used for LAN interface. utp : Unshielded twisted pair stp : Shielded twisted pair. newvalUtp : same functionality as 'utp', new enumeration added for RFC1155 compatibility." ::= { cdx6500PPCTdot5PortEntry 2 } cdx6500dot5PortMacAddress OBJECT-TYPE SYNTAX MacAddress ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the MAC address of the LAN port. The entered value of 00-00-00-00-00-00 will be replaced by the Burned In Address (BIA) if the LAN hardware is present." ::= { cdx6500PPCTdot5PortEntry 3 } cdx6500dot5LocalRingNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This parameter specifies the local ring number to which this port is attached. It is used as default if a value is not obtained from Ring Parameter Server." ::= { cdx6500PPCTdot5PortEntry 4 } cdx6500dot5EarlyTokenRelease OBJECT-TYPE SYNTAX INTEGER { disable (0), enable (1), newvalDisable (50) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter controls whether this station operating on a 16 Mbps ring will perform early token release. This parameter has no effect for 4 Mbps rings where early token release is not used. newvalDisable : same functionality as 'disable', new enumeration added for RFC1155 compatibility." ::= { cdx6500PPCTdot5PortEntry 5 } cdx6500dot5TransmitQueueLimit OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames that can be queued on the transmitter before any frame is dropped." ::= { cdx6500PPCTdot5PortEntry 6 } -- This table contains statistics and error counter which are -- specific to 802.5 interfaces. These objects are in addition -- to those listed in RFC1231. cdx6500PPSTdot5PortTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500PPSTdot5Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing Token Ring statistics, one entry per 802.5 interface. All the statistics are defined using the syntax Counter as 32-bit wrap around counters. Thus, if an interface's hardware maintains these statistics in 16-bit counters, then the agent must read the hardware's counters frequently enough to prevent loss of significance, in order to maintain 32-bit counters in software." ::= { cdx6500PSTPortProtocolGroup 9 } cdx6500PPSTdot5PortEntry OBJECT-TYPE SYNTAX Cdx6500PPSTdot5Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry contains the 802.5 statistics for a particular interface." INDEX { cdx6500dot5StatsIfIndex } ::= { cdx6500PPSTdot5PortTable 1 } Cdx6500PPSTdot5Entry ::= SEQUENCE { cdx6500dot5StatsIfIndex INTEGER, cdx6500dot5StatsPortType INTEGER, cdx6500dot5StatsDataBytesRx Counter, cdx6500dot5StatsDataBytesTx Counter, cdx6500dot5StatsFrameSizeExc Counter, cdx6500dot5StatsShortFrames Counter, cdx6500dot5StatsTransmitDiscards Counter, cdx6500dot5StatsPortStatus INTEGER, cdx6500dot5StatsLastStatReset DisplayString, cdx6500dot5StatsClearStats INTEGER } cdx6500dot5StatsIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the 802.5 interface for which this entry contains management information." ::= { cdx6500PPSTdot5PortEntry 1 } cdx6500dot5StatsPortType OBJECT-TYPE SYNTAX INTEGER { tr (28) } ACCESS read-only STATUS mandatory DESCRIPTION "The currently running value of the Port type." ::= { cdx6500PPSTdot5PortEntry 2 } cdx6500dot5StatsDataBytesRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented for each data byte received by the LAN port." ::= { cdx6500PPSTdot5PortEntry 3 } cdx6500dot5StatsDataBytesTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented for each data byte transmitted by the LAN port." ::= { cdx6500PPSTdot5PortEntry 4 } cdx6500dot5StatsFrameSizeExc OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented when the LAN port observes a frame that can not be forwarded because of excessive length." ::= { cdx6500PPSTdot5PortEntry 5 } cdx6500dot5StatsShortFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented when the LAN port observes a receive or transmitted frame which is less than 18 bytes." ::= { cdx6500PPSTdot5PortEntry 6 } cdx6500dot5StatsTransmitDiscards OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented when the LAN port discards the frame because the transmit queue exceeds the maximum queue length." ::= { cdx6500PPSTdot5PortEntry 7 } cdx6500dot5StatsPortStatus OBJECT-TYPE SYNTAX INTEGER { disabled (0), enabled (1), up (3), down (4), newvalDisabled (50) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the status of the LAN port. newvalDisabled : same functionality as 'disabled', new enumeration added for RFC1155 compatibility." ::= { cdx6500PPSTdot5PortEntry 8 } cdx6500dot5StatsLastStatReset OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Time stamp when the statistics were last reset." ::= { cdx6500PPSTdot5PortEntry 9 } cdx6500dot5StatsClearStats OBJECT-TYPE SYNTAX INTEGER { reset (1) } ACCESS write-only STATUS mandatory DESCRIPTION "This is the command to reset the LAN port statistics." ::= { cdx6500PPSTdot5PortEntry 10 } END