PrETS5 {ccitt(0) identified-organization(4) etsi(0) ets304(304) informationModel(0) asn1Module(2) prETS5(0)} DEFINITIONS IMPLICIT TAGS ::= BEGIN -- EXPORT Everything prETS300304 OBJECT IDENTIFIER ::= {ccitt(0) identified-organization(4) etsi(0) ets304(304) informationModel(0)} etsObjectClass OBJECT IDENTIFIER ::= {prETS300304 managedObjectClass(3)} etsPackage OBJECT IDENTIFIER ::= {prETS300304 package(4)} etsParameter OBJECT IDENTIFIER ::= {prETS300304 parameter(5)} etsNameBinding OBJECT IDENTIFIER ::= {prETS300304 nameBinding(6)} etsAttribute OBJECT IDENTIFIER ::= {prETS300304 attribute(7)} etsAction OBJECT IDENTIFIER ::= {prETS300304 action(9)} etsNotification OBJECT IDENTIFIER ::= {prETS300304 notification(10)} END BEGIN IMPORTS alarmRecord, attributeValueChangeRecord, eventForwardingDiscriminator, log, objectCreationRecord objectDeletionRecord stateChangeRecord, FROM {joint-iso-ccitt ms(9) smi(3) part2(2) managedObjectClass(3) } alarmSeverityAssignmentProfile FROM {ccitt(0) recommendation(0) m(13) m3100(3100) informationModel(0) managedObjectClass(3) } ; END BEGIN IMPORTS au4CTPBidirectional, au4CTPSink, au4CTPSource, augBidirectional, augSink, augSource, electricalSPITTPBidirectional, electricalSPITTPSink, electricalSPITTPSource, msCTPBidirectional, msCTPSink, msCTPSource, msDatacomCTPBidirectional, msDatacomCTPSink, msDatacomCTPSource, msOrderwireCTPBidirectional, msOrderwireCTPSink, msOrderwireCTPSource, msTTPBidirectional, msTTPSink, msTTPSource, opticalSPITTPBidirectional, opticalSPITTPSink, opticalSPITTPSource, rsCTPBidirectional, rsCTPSink, rsCTPSource, rsDatacomCTPBidirectional, rsDatacomCTPSink, rsDatacomCTPSource, rsOrderwireCTPBidirectional, rsOrderwireCTPSink, rsOrderwireCTPSource, rsTTPBidirectional, rsTTPSink, rsTTPSource, rsUserChannelCTPBidirectional, rsUserChannelCTPSink, rsUserChannelCTPSource, tu11CTPBidirectional, tu11CTPSink, tu11CTPSource, tu12CTPBidirectional, tu12CTPSink, tu12CTPSource, tu2CTPBidirectional, tu2CTPSink, tu2CTPSource, tu3CTPBidirectional, tu3CTPSink, tu3CTPSource, tug2Bidirectional, tug2Sink, tug2Source, tug3Bidirectional, tug3Sink, tug3Source, vc11TTPBidirectional, vc11TTPSink, vc11TTPSource, vc12TTPBidirectional, vc12TTPSink, vc12TTPSource, vc2TTPBidirectional, vc2TTPSink, vc2TTPSource, vc3TTPBidirectional, vc3TTPSink, vc3TTPSource, vc4TTPBidirectional, vc4TTPSink, vc4TTPSource, vcnUserChannelCTPBidirectional, vcnUserChannelCTPSink, vcnUserChannelCTPSource FROM {ccitt(0) recommendation(0) g(7) g774(774) informationModel(0) managedObjectClass(3) } ; END supportedByObjectList The value of the supportedByObjectList attribute points to the equipment and software objects which implement the TPs. BEGIN IMPORTS au4CTPBidirectional-augBidirectional, au4CTPSink-augBidirectional, au4CTPSink-augSink, au4CTPSource-augBidirectional, au4CTPSource-augSource, augBidirectional-msTTPBidirectional, augSink-msTTPSink, augSource-msTTPSource, electricalSPITTPBidirectional-sdhNE, electricalSPITTPSink-sdhNE, electricalSPITTPSource-sdhNE, msCTPBidirectional-rsTTPBidirectional, msCTPSink-rsTTPBidirectional, msCTPSink-rsTTPSink, msCTPSource-rsTTPBidirectional, msCTPSource-rsTTPSource, msDatacomCTPBidirectional-msTTPBidirectional, msDatacomCTPSink-msTTPBidirectional, msDatacomCTPSink-msTTPSink, msDatacomCTPSource-msTTPBidirectional, msDatacomCTPSource-msTTPSource, msOrderwireCTPBidirectional-msTTPBidirectional, msOrderwireCTPSink-msTTPBidirectional, msOrderwireCTPSink-msTTPSink, msOrderwireCTPSource-msTTPBidirectional, msOrderwireCTPSource-msTTPSource, msTTPBidirectional-sdhNE, msTTPSink-sdhNE, msTTPSource-sdhNE, opticalSPITTPBidirectional-sdhNE, opticalSPITTPSink-sdhNE, opticalSPITTPSource-sdhNE, rsCTPBidirectional-electricalSPITTPBidirectional, rsCTPBidirectional-opticalSPITTPBidirectional, rsCTPSink-electricalSPITTPBidirectional, rsCTPSink-electricalSPITTPSink, rsCTPSink-opticalSPITTPBidirectional, rsCTPSink-opticalSPITTPSink, rsCTPSource-electricalSPITTPBidirectional, rsCTPSource-electricalSPITTPSource, rsCTPSource-opticalSPITTPBidirectional, rsCTPSource-opticalSPITTPSource, rsDatacomCTPBidirectional-rsTTPBidirectional, rsDatacomCTPSink-rsTTPBidirectional, rsDatacomCTPSink-rsTTPSink, rsDatacomCTPSource-rsTTPBidirectional, rsDatacomCTPSource-rsTTPSource, rsOrderwireCTPBidirectional-rsTTPBidirectional, rsOrderwireCTPSink-rsTTPBidirectional, rsOrderwireCTPSink-rsTTPSink, rsOrderwireCTPSource-rsTTPBidirectional, rsOrderwireCTPSource-rsTTPSource, rsTTPBidirectional-sdhNE, rsTTPSink-sdhNE, rsTTPSource-sdhNE, rsUserChannelCTPBidirectional-rsTTPBidirectional, rsUserChannelCTPSink-rsTTPBidirectional, rsUserChannelCTPSink-rsTTPSink, rsUserChannelCTPSource-rsTTPBidirectional, rsUserChannelCTPSource-rsTTPSource, tu11CTPBidirectional-tug2Bidirectional, tu11CTPSink-tug2Bidirectional, tu11CTPSink-tug2Sink, tu11CTPSource-tug2Bidirectional, tu11CTPSource-tug2Source, tu12CTPBidirectional-tug2Bidirectional, tu12CTPSink-tug2Bidirectional, tu12CTPSink-tug2Sink, tu12CTPSource-tug2Bidirectional, tu12CTPSource-tug2Source, tu2CTPBidirectional-tug2Bidirectional, tu2CTPSink-tug2Bidirectional, tu2CTPSink-tug2Sink, tu2CTPSource-tug2Bidirectional, tu2CTPSource-tug2Source, tu3CTPBidirectional-tug3Bidirectional, tu3CTPSink-tug3Bidirectional, tu3CTPSink-tug3Sink, tu3CTPSource-tug3Bidirectional, tu3CTPSource-tug3Source, tug2Bidirectional-tug3Bidirectional, tug2Sink-tug3Sink, tug2Source-tug3Source, tug3Bidirectional-vc4TTPBidirectional, tug3Sink-vc4TTPSink, tug3Source-vc4TTPSource, vc11TTPBidirectional-sdhNE, vc11TTPSink-sdhNE, vc11TTPSource-sdhNE, vc12TTPBidirectional-sdhNE, vc12TTPSink-sdhNE, vc12TTPSource-sdhNE, vc2TTPBidirectional-sdhNE, vc2TTPSink-sdhNE, vc2TTPSource-sdhNE, vc3TTPBidirectional-sdhNE, vc3TTPSink-sdhNE, vc3TTPSource-sdhNE, vc4TTPBidirectional-sdhNE, vc4TTPSink-sdhNE, vc4TTPSource-sdhNE, vcnUserChannelCTPBidirectional-vc3TTPBidirectional, vcnUserChannelCTPBidirectional-vc4TTPBidirectional, vcnUserChannelCTPSink-vc3TTPBidirectional, vcnUserChannelCTPSink-vc3TTPSink, vcnUserChannelCTPSink-vc4TTPBidirectional, vcnUserChannelCTPSink-vc4TTPSink, vcnUserChannelCTPSource-vc3TTPBidirectional, vcnUserChannelCTPSource-vc3TTPSource, vcnUserChannelCTPSource-vc4TTPBidirectional, vcnUserChannelCTPSource-vc4TTPSource FROM {ccitt(0) recommendation(0) g(7) g774(774) informationModel(0) nameBinding(6) } ; END BEGIN IMPORTS augSinkSubordination, augSourceSubordination, augBidirectionalSubordination, electricalSPITTPSinkSubordination, electricalSPITTPSourceSubordination, electricalSPITTPBidirectionalSubordination, opticalSPITTPSinkSubordination, opticalSPITTPSourceSubordination, opticalSPITTPBidirectionalSubordination, msTTPSinkSubordination, msTTPSourceSubordination, msTTPBidirectionalSubordination, rsTTPSinkSubordination, rsTTPSourceSubordination, rsTTPBidirectionalSubordination, sdhNESubordination, tug2SinkSubordination, tug2SourceSubordination, tug2BidirectionalSubordination, tug3SinkSubordination, tug3SourceSubordination, tug3BidirectionalSubordination, vc3TTPSinkSubordination, vc3TTPSourceSubordination, vc3TTPBidirectionalSubordination, vc4TTPSinkSubordination, vc4TTPSourceSubordination, vc4TTPBidirectionalSubordination, FROM {ccitt(0) recommendation(0) g(7) g774(774)} ; END BEGIN IMPORTS downstreamConnectivityPointer-au4CTPSink, upstreamConnectivityPointer-au4CTPSource, downstreamConnectivityPointer-msCTPSink, upstreamConnectivityPointer-msCTPSource, upstreamConnectivityPointer-msTTPSink, downstreamConnectivityPointer-msTTPSource, downstreamConnectivityPointer-rsCTPSink, upstreamConnectivityPointer-rsCTPSource, upstreamConnectivityPointer-rsTTPSink, downstreamConnectivityPointer-rsTTPSource, downstreamConnectivityPointer-tu11CTPSink, upstreamConnectivityPointer-tu11CTPSource, downstreamConnectivityPointer-tu12CTPSink, upstreamConnectivityPointer-tu12CTPSource, downstreamConnectivityPointer-tu2CTPSink, upstreamConnectivityPointer-tu2CTPSource, downstreamConnectivityPointer-tu3CTPSink, upstreamConnectivityPointer-tu3CTPSource, upstreamConnectivityPointer-vc11TTPSink, downstreamConnectivityPointer-vc11TTPSource, upstreamConnectivityPointer-vc12TTPSink, downstreamConnectivityPointer-vc12TTPSource, upstreamConnectivityPointer-vc2TTPSink, downstreamConnectivityPointer-vc2TTPSource, upstreamConnectivityPointer-vc3TTPSink, downstreamConnectivityPointer-vc3TTPSource, FROM {ccitt(0) recommendation(0) g(7) g774(774)} ; END ets_upstreamConnectivityPointer-vc4TTPSink CONSTRAINT RULE OBJECT CLASS vc4TTPSink AND SUBCLASSES; IS RELATED TO vc4TTPSource, vc4TTPBidirectional, au4CTPSink, au4CTPBidirectional; USING ATTRIBUTE "Recommendation M.3100":upstreamConnectivityPointer; ACCORDING TO RULE SET SIZE (1) OF CHOICE{ vc4TTPSource, vc4TTPBidirectional, au4CTPSink, au4CTPBidirectional}; ; ets_downstreamConnectivityPointer-vc4TTPSource CONSTRAINT RULE OBJECT CLASS vc4TTPSource AND SUBCLASSES; IS RELATED TO vc4TTPSink, vc4TTPBidirectional, au4CTPSource, au4CTPBidirectional; USING ATTRIBUTE "Recommendation M.3100":downstreamConnectivityPointer; CASE{ single ACCORDING TO RULE SET SIZE (1) OF CHOICE{ vc4TTPSink, vc4TTPBidirectional, au4CTPSource, au4CTPBidirectional}; ; broadcast ACCORDING TO RULE SET SIZE (1..N) OF CHOICE{ vc4TTPSink, vc4TTPBidirectional, au4CTPSource, au4CTPBidirectional}; } ITU-T Recommendation G.702 2 Mbit/s connection termination point p12CTPSink MANAGED OBJECT CLASS DERIVED FROM "Recommendation M.3100":connectionTerminationPointSink; CHARACTERIZED BY "Recommendation M.3100":createDeleteNotificationsPackage, "Recommendation M.3100":operationalStatePackage, "Recommendation M.3100":stateChangeNotificationPackage, p12CTPSinkPkg PACKAGE BEHAVIOUR p12CTPSinkBehaviourPkg BEHAVIOUR DEFINED AS *This managed object class terminates a G.702 2 Mbit/s connection and includes the lower order path adaptation function (LPA).* ;; ATTRIBUTES p12CTPId GET; ;; REGISTERED AS { etsObjectClass 13 }; p12CTPSource MANAGED OBJECT CLASS DERIVED FROM "Recommendation M.3100":connectionTerminationPointSource; CHARACTERIZED BY "Recommendation M.3100":createDeleteNotificationsPackage, p12CTPSourcePkg PACKAGE BEHAVIOUR p12CTPSourceBehaviourPkg BEHAVIOUR DEFINED AS *This object class originates a G.702 2 Mbit/s connection* ;; ATTRIBUTES p12CTPId GET; ;; REGISTERED AS { etsObjectClass 2 }; p12CTPBidirectional MANAGED OBJECT CLASS DERIVED FROM "Recommendation M.3100":connectionTerminationPointBidirectional, p12CTPSink, p12CTPSource; REGISTERED AS { etsObjectClass 3 }; G702 34 Mbit/s connection termination point p31CTPSink MANAGED OBJECT CLASS DERIVED FROM "Recommendation M.3100":connectionTerminationPointSink; CHARACTERIZED BY "Recommendation M.3100":createDeleteNotificationsPackage, "Recommendation M.3100":operationalStatePackage, "Recommendation M.3100":stateChangeNotificationPackage, p31CTPSinkPkg PACKAGE BEHAVIOUR p31CTPSinkBehaviourPkg BEHAVIOUR DEFINED AS *This managed object class terminates a G.702 34 Mbit/s connection and includes the lower order path adaptation function (LPA).* ;; ATTRIBUTES p31CTPId GET; ;; REGISTERED AS { etsObjectClass 4 }; p31CTPSource MANAGED OBJECT CLASS DERIVED FROM "Recommendation M.3100":connectionTerminationPointSource; CHARACTERIZED BY "Recommendation M.3100":createDeleteNotificationsPackage, p31CTPSourcePkg PACKAGE BEHAVIOUR p31CTPSourceBehaviourPkg BEHAVIOUR DEFINED AS *This object class originates a G.702 34Mbit/s connection.* ;; ATTRIBUTES p31CTPId GET; ;; REGISTERED AS { etsObjectClass 5 }; p31CTPBidirectional MANAGED OBJECT CLASS DERIVED FROM "Recommendation M.3100":connectionTerminationPointBidirectional, p31CTPSink, p31CTPSource; REGISTERED AS { etsObjectClass 6 }; G702 140 Mbit/s connection termination point p4CTPSink MANAGED OBJECT CLASS DERIVED FROM "Recommendation M.3100":connectionTerminationPointSink; CHARACTERIZED BY "Recommendation M.3100":createDeleteNotificationsPackage, "Recommendation M.3100":operationalStatePackage, "Recommendation M.3100":stateChangeNotificationPackage, p4CTPSinkPkg PACKAGE BEHAVIOUR p4CTPSinkBehaviourPkg BEHAVIOUR DEFINED AS *This managed object class terminates a G.702 140 Mbit/s connection and includes the lower order path adaptation function (LPA).* ;; ATTRIBUTES p4CTPId GET; ;; REGISTERED AS { etsObjectClass 7 }; p4CTPSource MANAGED OBJECT CLASS DERIVED FROM "Recommendation M.3100":connectionTerminationPointSource; CHARACTERIZED BY "Recommendation M.3100":createDeleteNotificationsPackage, p4CTPSourcePkg PACKAGE BEHAVIOUR p4CTPSourceBehaviourPkg BEHAVIOUR DEFINED AS *This object class originates a G.702 140 Mbit/s connection.* ;; ATTRIBUTES p4CTPId GET; ;; REGISTERED AS { etsObjectClass 8 }; p4CTPBidirectional MANAGED OBJECT CLASS DERIVED FROM "Recommendation M.3100":connectionTerminationPointBidirectional, p4CTPSink, p4CTPSource; REGISTERED AS { etsObjectClass 9 }; supportedByObjectList The value of the supportedByObjectList attribute points to the equipment and software objects which implement the TPs. G.702 2Mbit/s Connection Termination Point Identification p12CTPId ATTRIBUTE WITH ATTRIBUTE SYNTAX PrETS8.NameType ; MATCHES FOR EQUALITY; BEHAVIOUR p12CTPIdBehaviour BEHAVIOUR DEFINED AS This attribute is used as an RDN for naming instances of the p12CTP object classes. ;; REGISTERED AS { etsAttribute 1 }; G.702 34Mbit/s Connection Termination Point Identification p31CTPId ATTRIBUTE WITH ATTRIBUTE SYNTAX PrETS8.NameType ; MATCHES FOR EQUALITY; BEHAVIOUR p31CTPIdBehaviour BEHAVIOUR DEFINED AS This attribute is used as an RDN for naming instances of the p31CTP object classes. ;; REGISTERED AS { etsAttribute 2 }; G.702 140Mbit/s Connection Termination Point Identification p4CTPId ATTRIBUTE WITH ATTRIBUTE SYNTAX PrETS8.NameType ; MATCHES FOR EQUALITY; BEHAVIOUR p4CTPIdBehaviour BEHAVIOUR DEFINED AS This attribute is used as an RDN for naming instances of the p4CTP object classes. ;; REGISTERED AS { etsAttribute 3 }; p12CTPSource-G774vc12TTPSource NAME BINDING SUBORDINATE OBJECT CLASS p12CTPSource AND SUBCLASSES; NAMED BY SUPERIOR OBJECT CLASS "Recommendation G.774":vc12TTPSource AND SUBCLASSES; WITH ATTRIBUTE p12CTPId; BEHAVIOUR p12CTPSource-vc12TTPSource BEHAVIOUR DEFINED AS The subordinate managed object may be automatically instantiated when the superior managed object is instantiated, according to the make-up and mode of operation of the equipment. ;; REGISTERED AS { etsNameBinding 20 }; p12CTPSink-G774vc12TTPSink NAME BINDING SUBORDINATE OBJECT CLASS p12CTPSink AND SUBCLASSES; NAMED BY SUPERIOR OBJECT CLASS "Recommendation G.774":vc12TTPSink AND SUBCLASSES; WITH ATTRIBUTE p12CTPId; BEHAVIOUR p12CTPSink-vc12TTPSink BEHAVIOUR DEFINED AS The subordinate managed object may be automatically instantiated when the superior managed object is instantiated, according to the make-up and mode of operation of the equipment. ;; REGISTERED AS { etsNameBinding 21 }; p31CTPSource-G774vc3TTPSource NAME BINDING SUBORDINATE OBJECT CLASS p31CTPSource AND SUBCLASSES; NAMED BY SUPERIOR OBJECT CLASS "Recommendation G.774":vc3TTPSource AND SUBCLASSES; WITH ATTRIBUTE p31CTPId; BEHAVIOUR p31CTPSource-vc3TTPSource BEHAVIOUR DEFINED AS The subordinate managed object may be automatically instantiated when the superior managed object is instantiated, according to the make-up and mode of operation of the equipment. ;; REGISTERED AS { etsNameBinding 22 }; p31CTPSink-G774vc3TTPSink NAME BINDING SUBORDINATE OBJECT CLASS p31CTPSink AND SUBCLASSES; NAMED BY SUPERIOR OBJECT CLASS "Recommendation G.774":vc3TTPSink AND SUBCLASSES; WITH ATTRIBUTE p31CTPId; BEHAVIOUR p31CTPSink-vc3TTPSink BEHAVIOUR DEFINED AS The subordinate managed object may be automatically instantiated when the superior managed object is instantiated, according to the make-up and mode of operation of the equipment. ;; REGISTERED AS { etsNameBinding 23 }; p4CTPSource-G774vc4TTPSource NAME BINDING SUBORDINATE OBJECT CLASS p4CTPSource AND SUBCLASSES; NAMED BY SUPERIOR OBJECT CLASS "Recommendation G.774":vc4TTPSource AND SUBCLASSES; WITH ATTRIBUTE p4CTPId; BEHAVIOUR p4CTPSource-vc4TTPSource BEHAVIOUR DEFINED AS The subordinate managed object may be automatically instantiated when the superior managed object is instantiated, according to the make-up and mode of operation of the equipment. ;; REGISTERED AS { etsNameBinding 24 }; p4CTPSink-G774vc4TTPSink NAME BINDING SUBORDINATE OBJECT CLASS p4CTPSink AND SUBCLASSES; NAMED BY SUPERIOR OBJECT CLASS "Recommendation G.774":vc4TTPSink AND SUBCLASSES; WITH ATTRIBUTE p4CTPId; BEHAVIOUR p4CTPSink-vc4TTPSink BEHAVIOUR DEFINED AS The subordinate managed object may be automatically instantiated when the superior managed object is instantiated, according to the make-up and mode of operation of the equipment. ;; REGISTERED AS { etsNameBinding 25 }; PrETS8{ccitt(0) identified-organization(4) etsi(0) ets304(304) informationModel(0) asn1Module(2) prETS8(1)} DEFINITIONS IMPLICIT TAGS ::= BEGIN -- EXPORTS everything IMPORTS NameType FROM ASN1DefinedTypesModule {ccitt(0) recommendation(0) m(13) m3100(3100) informationModel(0) asn1Module(2) asn1DefinedTypesModule(0)} END -- end of ASN1DefinedTypesModule BEGIN IMPORTS crossConnection, fabric, gtp, mpCrossConnection, tpPool FROM {ccitt(0) recommendation(0) m(13) m3100(3100) informationModel(0) managedObjectClass(3) } ; END supportedByObjectList The value of the supportedByObjectList attribute points to the equipment and software objects which implement the TPs. BEGIN IMPORTS fabric-managedElement, gtp-fabric, mpCrossConnection-fabric, tpPool-fabric FROM {ccitt(0) recommendation(0) m(13) m3100(3100) informationModel(0) nameBinding(6) } ; END etsCrossConnection-fabric NAME BINDING SUBORDINATE OBJECT CLASS "Recommendation M.3100" : crossConnection AND SUBCLASSES; NAMED BY SUPERIOR OBJECT CLASS "Recommendation M.3100":fabric AND SUBCLASSES; WITH ATTRIBUTE "Recommendation M.3100":crossConnectionId; BEHAVIOUR etsCrossConnection-fabricBehaviour BEHAVIOUR DEFINED AS *The value of the fromTermination attribute in the crossConnection object shall not be NULL. When an instance of crossConnection is deleted, the following attributes will be affected. The crossConnectionObjectPointer attributes in the termination points or in the gtp objects that were pointing to the deleted crossConnection instance shall be set to point to the Fabric responsible for the connection of the termination points. The counters in the appropriate TP Pool objects (if applicable) shall be updated. The connectivityPointer attributes in the disconnected termination points shall be set to NULL. Deleting a crossConnection object instance has no effect on the composition of any GTP* ;; REGISTERED AS {etsNameBinding 16 }; etsCrossConnection-mpCrossConnection NAME BINDING SUBORDINATE OBJECT CLASS "Recommendation M.3100":crossConnection AND SUBCLASSES; NAMED BY SUPERIOR OBJECT CLASS "Recommendation M.3100":mpCrossConnection AND SUBCLASSES; WITH ATTRIBUTE "Recommendation M.3100":crossConnectionId; BEHAVIOUR etsCrossConnection-mpCrossConnectionBehaviour BEHAVIOUR DEFINED AS *The value of the fromTermination attribute in the crossConnection object must be NULL. When an instance of crossConnection is deleted, the following attributes will be affected. The crossConnectionObjectPointer attributes in the termination points or in the gtp objects that were pointing to the deleted crossConnection instance shall be set to point to the Fabric responsible for the connection of the termination points. The counters in the appropriate TP Pool objects (if applicable) shall be updated. The connectivityPointer attributes in the disconnected termination points shall be set to NULL. Deleting the last cross-Connection contained in a multipoint cross connection object has the effect of also deleting the multipoint cross connection object instance (and updating the appropriate pointers). Deleting a crossConnection object instance has no effect on the composition of any GTP* ;; REGISTERED AS {etsNameBinding 17 }; BEGIN IMPORTS protectedTTPBidirectional protectedTTPSink protectedTTPSource protectionGroup protectionUnit sdhMSProtectionGroup sdhMSProtectionUnit unprotectedCTPBidirectional unprotectedCTPSink unprotectedCTPSource FROM {ccitt(0) recommendation(0) g(7) g774(774) hyphen(127) prot(03) informationModel(0) managedObjectClass(3) } ; END supportedByObjectList The value of the supportedByObjectList attribute points to the equipment and software objects which implement the TPs. BEGIN IMPORTS protectedTTPBidirectional-sdhNE protectedTTPSink-sdhNE protectedTTPSource-sdhNE augBidirectional-protectedTTPBidirectional augSink-protectedTTPSink augSource-protectedTTPSource protectionGroup-managedElement protectionUnit-protectionGroup unprotectedCTPBidirectional-msTTPBidirectional unprotectedCTPSink-msTTPSink unprotectedCTPSource-msTTPSource FROM {ccitt(0) recommendation(0) g(7) g774(774) hyphen(127) prot(03) informationModel(0) nameBinding(6) } ; END BEGIN IMPORTS sdhNE FROM {ccitt(0) recommendation(0) g(7) g774(774) informationModel(0) managedObjectClass(3) } software FROM M.3100ObjectClass {ccitt(0) recommendation(0) m(13) m3100(3100) informationModel(0) managedObjectClass(3) } ; END equipmentProtectionGroup MANAGED OBJECT CLASS DERIVED FROM "Recommendation G.774-03: 1994":protectionGroup; CHARACTERIZED BY equipmentProtectionGroupPkg PACKAGE BEHAVIOUR equipmentProtectionGroupBeh; NOTIFICATIONS "Recommendation G.774-03: 1994": protectionSwitchReporting equipmentProtectionStatusParameter;;; REGISTERED AS { etsObjectClass 14 }; equipmentProtectionGroupBeh BEHAVIOUR DEFINED AS " This object class is used specifically for representing an equipment protection group in a protection system. The invokeProtection action switches always from protectedUnit to protectingUnit. Either no or all equipmentProtectionUnits within an equipmentProtectionGroup shall have the priorityPkg package."; equipmentProtectionUnit MANAGED OBJECT CLASS DERIVED FROM "Recommendation G.774-03: 1994":protectionUnit; CHARACTERIZED BY "Recommendation M.3100: 1992":createDeleteNotificationsPackage, equipmentProtectionUnitPkg PACKAGE BEHAVIOUR equipmentProtectionUnitBeh; ATTRIBUTES equipmentProtectionStatus GET;;; REGISTERED AS { etsObjectClass 15 }; equipmentProtectionUnitBeh BEHAVIOUR DEFINED AS " This object class is specific to equipment protection systems. Instances of this object class are used to represent a relationship between a functional object and an equipment. equipmentProtectionUnits are self-instanciated by the agent according to the equipment protection schemes adopted by the NE. An equipmentProtectionUnit instance is deleted when the sdhEquipment instance pointed to by the unreliableResourcePointer attribute are deleted, and is created again if the sdhEquipment are instantiated with the appropriate equipmentExpected attribute value. The reliableResourcePointer inherited by the protectionUnit superclass can be optionally an empty set for instances of this object class. The agent can also create and delete instances of the equipmentProtectionUnit in order to reflect local modifications in the equipment protection schemes. The attributeValueChange notification shall only be used to notify changes of the priority attribute."; sdhEquipmentR MANAGED OBJECT CLASS DERIVED FROM "Recommendation M.3100":equipment; CHARACTERIZED BY "Recommendation M.3100":administrativeOperationalStatesPackage, "Recommendation M.3100":attributeValueChangeNotificationPackage, "Recommendation M.3100":createDeleteNotificationsPackage, "Recommendation M.3100":currentProblemListPackage, "Recommendation M.3100":locationNamePackage, "Recommendation M.3100":stateChangeNotificationPackage, "Recommendation M.3100":equipmentEquipmentAlarmPackage, "Recommendation X.721":availabilityStatusPackage, sdhEquipmentPackage PACKAGE BEHAVIOUR sdhEquipmentBehaviour BEHAVIOUR DEFINED AS * The equipment object may be instantiated or exist without the presence of the physical resources. In this case the operational state shall be "disabled" and the availability status attribute shall contain the value "notInstalled". When the resource is physically removed, the corresponding equipment object is not automatically deleted. The equipmentExpected attribute shall be provided at instantiation time. The create request shall fail if the value of this attribute is unacceptable to the NE, and the failure reason shall indicate this mismatch in the response. When there is a mismatch in the contents of the equipmentActual and the equipment Expected attribute, an equipmentAlarm notification with probable cause "replaceableUnitTypeMis match" shall be raised. This checking is only performed if the availabilityStatus does not contain the value "notInstalled". The equipmentExpected value of "NULL" (no type) does not match any other value than NULL for equipmentActual. Changes in the value of the equipmentExpected attribute can only be achieved by object deletion and creation. The "Recommendation M.3100":versionPackage package is not used. The protectionUnitPointer attribute is used to point to a equipmentProtectionUnit within a equipmentProtectionGroup if the equipment is protectet. Otherwise the Pointer is null. One equipment could participate in several equipmentProtectionUnits at the same time.* ;; ATTRIBUTES "Recommendation M.3100":version GET, equipmentExpected GET, equipmentActual GET, specificPhysicalInstance GET, physicalConnectorList GET, protectionUnitPointer GET; ;; REGISTERED AS { etsObjectClass 16 }; affectedObjectList The value of the affectedObjectList attribute represents the functional objects implemented by the equipment or software object in which the attribute is applied. If the equipment or software object become disabled, all managed objects referred to by the affectedObjectList shall also be disabled. equipmentActual ATTRIBUTE WITH ATTRIBUTE SYNTAX PrETS12.EquipmentActual; BEHAVIOUR equipmentActualBehaviour BEHAVIOUR DEFINED AS This attribute contains the equipment type of the equipment actually present. The "EquipmentType" value is a vendor-specific identification of a particular set or class of equipment, where all the set members have equivalent capability. ;; REGISTERED AS {etsAttribute 4 }; equipmentExpected ATTRIBUTE WITH ATTRIBUTE SYNTAX PrETS12.EquipmentExpected; BEHAVIOUR equipmentExpectedBehaviour BEHAVIOUR DEFINED AS This attribute contains the equipment type requested at object creation. The "EquipmentType" value is a vendor-specific identification of a particular set or class of equipment, where all the set members have equivalent capability. ;; REGISTERED AS {etsAttribute 5}; equipmentProtectionStatus ATTRIBUTE WITH ATTRIBUTE SYNTAX PrETS12.EquipmentProtectionStatus; MATCHES FOR EQUALITY, SET-COMPARISON, SET-INTERSECTION; BEHAVIOUR equipmentProtectionStatusBeh; REGISTERED AS { etsAttribute 12 }; equipmentProtectionStatusBeh BEHAVIOUR DEFINED AS " This attribute is used to indicate the status of the protection switch in a protectionUnit instance. The remainder of this behaviour provides the allowable equipmentProtectionStatus attribute values for protected and protecting units for both revertive and non-revertive systems. The following allowable equipmentProtectionStatus values are associated with each protected unit: No Request: No switch request is present on the unit. Manual Switch to Protecting Complete: The unit has completed a Manual Switch. Automatic Switch Pending: The unit has a failure condition present and the protecting unit is unavailable. Automatic Switch Complete: The unit has completed an Automatic Switch to the protecting unit due to failure condition. Force Switch Complete, Automatic Switch Pending: The unit has completed a Force Switch. Additionally, the unit has an automatic switch pending. Automatic Switch Complete, Wait-to-Restore: The unit has completed an Automatic Switch to the protecting unit. (revertive case only) Force Switch Complete: The unit has completed a Force Switch to the protecting unit. Protected Unit Lockout Completed: The unit has been locked out from the protecting unit. Additionally the non-revertive protected protection unit has the following status values: Do Not Revert: The protected unit has been switched to the protecting unit and the request to do so has been released. The switch to the protecting unit is maintained. The following allowable protectionStatus values are associated with each protecting unit: No Request: No request is present on the protecting unit. Manual Switch to Protecting Unit Complete: The protected unit has completed a Manual Switch. Automatic Switch Complete to Protecting Unit: The protected unit has completed an automatic switch to the protecting unit. Automatic Switch Complete to Protecting Unit, Wait to Restore: The unit has completed an Automatic Switch to the protecting unit. (revertive case only) Protecting Unit Failed: The protecting unit has a failure condition present. Force Switch Complete to Protecting Unit: The unit has completed a Force Switch of a protected unit to the protecting unit. Protecting Unit Locked Out: The protecting unit has been locked out. Additionally, the non-revertive protecting unit has the following values: Do Not Revert: The protected unit has been switched to the protecting unit and the request to do so has been released. The switch to the protecting unit is maintained. Manual Switch to Protected Unit Complete: The unit has completed a Manual Switch from the protecting unit to the protected unit. " ; physicalConnectorList ATTRIBUTE WITH ATTRIBUTE SYNTAX PrETS12.PhysicalConnectorList; BEHAVIOUR physicalConnectorListBehaviour BEHAVIOUR DEFINED AS This attribute is used to relate external cabling to the appropriate transport objects. There is an entry per connector. ;; REGISTERED AS {etsAttribute 7 }; protectionUnitPointer ATTRIBUTE WITH ATTRIBUTE SYNTAX PrETS12.ProtectionUnitPointer; MATCHES FOR EQUALITY; REGISTERED AS {etsAttribute 13 }; specificPhysicalInstance ATTRIBUTE WITH ATTRIBUTE SYNTAX PrETS12.PhysicalInstance; BEHAVIOUR specificPhysicalInstanceBehaviour BEHAVIOUR DEFINED AS This attribute contains the unique identifier of the physical equipment (e.g. serial number). This may be a manufacturer dependent serial numbes or other unique identifier (or unknownInstance where the actual instance may not be determined from the actual equipment) ;; REGISTERED AS {etsAttribute 6 }; [ for information only. Version ::= -- Defined in M.3100, is used to present sufficient information to uniquely identify the "equipmentActual" for the purpose of repair or reordering. ] equipmentProtectionStatusParameter PARAMETER CONTEXT EVENT-INFO; WITH SYNTAX PrETS12.EquipmentProtectionStatusParameter; BEHAVIOUR equipmentProtectionStatusParameterBeh; REGISTERED AS { etsParameter 1 }; equipmentProtectionStatusParameterBeh BEHAVIOUR DEFINED AS "This parameter is included in the additional info parameters of the protection switching reporting notification. This notification is sent by the protection group according to the following rules. There are several cases: The switch from protected to protecting or protecting to protected has been done without preempting an existing switch. In this case the old and new values of the Protection Status attribute of the protecting channel shall be reported in the notification by means of the oldProtectionStatus and newProtectionStatus parameters respectively. A switch is perfomed by preemting an existing one. In this case the old and new values of the Protection Status attribute of the protecting unit shall be reported in the notification by means of the oldProtectionStatus and newProtectionStatus parameters respectively. An autoswitch condition exists on an equipment but the auto-switch cannot be served due to the unavailability of the equipment that otherwise protects it. In this case the oldProtectionStatus and newProtectionStatus parameters refer to the protection status attribute value of the equipment on which the autoswitch condition arises. The exception is when the equipment is already forced or locked out, in which case no notification is sent. A working equipment (protected unit) has been locked out or released from lockout without modifying any existing switch. In this case the oldProtectionStatus and newProtectionStatus parameters refer to the protection status attribute value of the working equipment which has been locked out. A protection equipment (protecting unit) has been lockout or released from lockout without modifying the existing switch. In this case the oldProtectionStatus and newProtectionStatus parameters refer to the protection status attribute value of the protection equipment which has been lockout. The protectionSwitchReporting is not sent when the automatic switch condition is toggling between the equipment failure and WTR condition. While in the lockout of forced switch state no notification is sent except for ending of release failure."; BEGIN IMPORTS equipment-managedElement, equipment-equipment FROM {ccitt(0) recommendation(0) m(13) m3100(3100) informationModel(0) nameBinding(6) } ; END PrETS12{ccitt(0)identified-organization(4)etsi(0)ets304(304)informationModel(0)asn1Module(2) prETS12(3)} DEFINITIONS IMPLICIT TAGS ::= BEGIN -- EXPORTS everything IMPORTS Version FROM ASN1DefinedTypesModule {ccitt(0) recommendation(0) m(13) m3100(3100) informationModel(0) asn1Module(2) asn1DefinedTypesModule(0)} RDNSequence FROM InformationFramework {joint-iso-ccitt ds(5) modules(1) informationFramework(1)} ObjectInstance FROM CMIP-1 {joint-iso-ccitt(2) ms(9) cmip(1) modules(0) protocol(3)} SwitchStatus, FromAndToProtectionUnit FROM SDHProtASN1 {itu-t recommendation(0) g(7) g774(774) hyphen(127) prot(03) informationModel(0) asn1Module(2) sdhmsp(0)}; Connector ::= SEQUENCE { connectorType PrintableString, connectorLocation PrintableString, supporting ListOfLocalDistinguishedName} EquipmentActual ::= CHOICE { noType NULL, type EquipmentType} EquipmentAutoSwitchReason ::= CHOICE { waitToRestore [0] NULL, equipmentFailure [1] NULL } EquipmentExpected ::= CHOICE { noType NULL, type EquipmentType} EquipmentProtectionStatus ::= SET OF CHOICE { noRequest [0] NULL, doNotRevert [1] NULL, manualSwitch [2] SEQUENCE { switchStatus [0] SwitchStatus, protectionUnitsSwitched [1] FromAndToProtectionUnit}, autoSwitch [3] SEQUENCE { switchStatus [0] SwitchStatus, protectionUnitsSwitched [1] FromAndToProtectionUnit, autoSwitchReason [2] EquipmentAutoSwitchReason}, forcedSwitch [4] SEQUENCE { switchStatus [0] SwitchStatus, protectionUnitsSwitched [1] FromAndToProtectionUnit}, lockout [5] SwitchStatus} EquipmentProtectionStatusParameter ::= SEQUENCE { oldProtectionStatus EquipmentProtectionStatus, newProtectionStatus EquipmentProtectionStatus} EquipmentType ::= PrintableString ListOfLocalDistinguishedName ::= SET OF RDNSequence PhysicalConnectorList ::= SET OF Connector PhysicalInstance ::= CHOICE { unknownInstance NULL, instance PrintableString} ProtectionUnitPointer ::= CHOICE { pointer SET OF ObjectInstance null NULL } END -- end of ASN1DefinedTypesModule powerSupply MANAGED OBJECT CLASS DERIVED FROM "Recommendation X.721":top; CHARACTERIZED BY "Recommendation M.3100":createDeleteNotificationsPackage, powerSupplyPackage PACKAGE BEHAVIOUR powerSupplyBehaviourPkg BEHAVIOUR DEFINED AS The power supply object class is used to control the power supply sources within the SDHNE. There shall be one instance for each of the power supply sources. ; ; ATTRIBUTES powerSupplyId GET, powerSource GET, poweredEquipmentPtrList GET, "Recommendation X.721":operationalState GET, "Recommendation M.3100":supportedByObjectList GET; NOTIFICATIONS "Recommendation X.721":attributeValueChange, "Recommendation X.721":stateChange; ;; REGISTERED AS { etsObjectClass 11 }; syncProtectionGroup MANAGED OBJECT CLASS DERIVED FROM "Recommendation G.774-03: 1994":protectionGroup; CHARACTERIZED BY syncProtectionGroupPkg PACKAGE BEHAVIOUR syncProtectionGroupBeh; NOTIFICATIONS "Recommendation G.774-03: 1994":protectionSwitchReporting syncProtectionStatusParameter;;; CONDITIONAL PACKAGES squelchStatusPkg PRESENT IF *an instance represents the T4 selection function*, squelchThresholdsPkg PRESENT IF *an instance represents the T4 selection function and the SSM algorithm is supported*, sSMActivePackage PRESENT IF *activation/deactivation of the SSM algorithm is supported*; REGISTERED AS { etsObjectClass 17 }; syncProtectionGroupBeh BEHAVIOUR DEFINED AS "This object class is specific to synchronisation protection. The creation/deletion of a syncProtectionGroup is performed by the NE depending upon its synchronisation protection capabilities (intrinsic knowledge of the NE). The operationalState attribute reflects only the switch capabilities of the protection scheme(i.e. it becomes disabled when the NE has detected that it can no longer perform switch operations (automatic or manual)). The manual switch operation can be performed among timing sources with the same or different priority and, when the SSM algorithm is active, with the same quality. A manual switch request between two timing sources with different quality levels and SSM algorithm is active will be rejected. The forced switch operation can be performed among any timing sources, independently of the priority and quality levels. All protectionUnits work in the protecting mode. The protectionSwitchReporting notification is sent by the synchronisation protection group according to the following rules. There are several cases: A switch from one protecting unit to another has occurred. In this case the new values of the protection status attributes of the protecting units which have been switched to and from shall be reported in the notification by means of the toProtectionStatus and fromProtectionStatus parameters respectively. A protecting unit has a failure or a clearing of a failure without causing a switch. In this case the fromProtectionStatus parameter is not used and the toProtectionStatus parameter refers to the protection status attribute value of the protecting unit which has a failure or a clearing of a failure. The exception is when the protecting unit is already forced or locked out, in which case no notification is sent. A protecting unit has been locked out or released from lockout without causing a switch. In this case the fromProtectionStatus parameter is not used and the toProtectionStatus parameter refers to the protection status attribute value of the protecting unit which has been locked out or released from lockout. A protecting unit has been manually switch or released from manual switch without causing a switch. In this case the fromProtectionStatus parameter is not used and the toProtectionStatus parameter refers to the protection status attribute value of the protecting unit which has been manually switch or released from manual switch. A protecting unit has been forced switch or released from forced switch without causing a switch. In this case the fromProtectionStatus parameter is not used and the toProtectionStatus parameter refers to the protection status attribute value of the protecting unit which has been forced switch or released from forced switch. While in the lockout or forced switch state, no notifications are sent "; syncProtectionUnit MANAGED OBJECT CLASS DERIVED FROM "Recommendation G.774-03: 1994":protectionUnit; CHARACTERIZED BY "Recommendation M.3100: 1992":createDeleteNotificationsPackage, syncProtectionUnitPkg PACKAGE BEHAVIOUR syncProtectionUnitBeh; ATTRIBUTES syncProtectionStatus GET;;; CONDITIONAL PACKAGES sSMQualityPackage PRESENT IF *the timing source has a SSM quality level*; REGISTERED AS { etsObjectClass 18 }; syncProtectionUnitBeh BEHAVIOUR DEFINED AS "This object class is specific to synchronisation protection. Instances of this object class are used to represent a relationship between a timing source and the timing generator(or a timing physical termination). All instances of this object class will act in the protecting role (i.e. there will not be a syncProtectionUnit with the protecting attribute set to FALSE), in order to ensure the consistency of the priority list. This object class can be created by the OS or the NE. When it is created by the OS, the OS must provide a value for the attribute unreliableResourcePointer."; timingGenerator MANAGED OBJECT CLASS DERIVED FROM "Recommendation X.721":top; CHARACTERIZED BY timingGeneratorPackage PACKAGE BEHAVIOUR timingGeneratorBehaviourPkg BEHAVIOUR DEFINED AS For the selection of the timing sources a 1:n protection like mechanism is used. Each protectionUnit in the protectionGroup has a pointer, the unreliableResourcePointer, which points to the related TP (see figure A.15). The currentTimingSourcePointer points to the timing source currently in use. A value of NULL of this attribute indicates the use of the internal oscillator. In that case, the unreliableResourcePointer of the corresponding protectionUnit also points to NULL. The reliableResourcePointer of the protectionUnit related to the currently used timing source points to the timingGenerator. The reliableResourcePointers of the other protectionUnits related to timing sources which are not currently in use are pointing to NULL. To select a special instance of a possible timing source, the OS has to use the invokeProtection action of the protectionGroup. Only one instance of this object class shall be created. ;; ATTRIBUTES timingGeneratorId GET, currentTimingSourcePointer GET, "Recommendation X.721":operationalState GET, "Recommendation M.3100":supportedByObjectList GET; NOTIFICATIONS "Recommendation X.721":attributeValueChange, "Recommendation X.721":stateChange; ;; REGISTERED AS { etsObjectClass 12 }; timingPhysicalTerminationBidirectional MANAGED OBJECT CLASS DERIVED FROM timingPhysicalTerminationSink, timingPhysicalTerminationSource; CHARACTERIZED BY timingPhysicalTerminationBidirectionalPkg PACKAGE BEHAVIOUR timingPhysicalTerminationBidirectionalBehaviour;;; REGISTERED AS { etsObjectClass 19 }; timingPhysicalTerminationBidirectionalBehaviour BEHAVIOUR DEFINED AS "This object class originates and terminates the 2 MHz signal."; timingPhysicalTerminationSink MANAGED OBJECT CLASS DERIVED FROM "Recommendation X.721: 1992":top; CHARACTERIZED BY timingPhysicalTerminationSinkPkg PACKAGE BEHAVIOUR timingPhysicalTerminationSinkBehaviour; ATTRIBUTES timingPhysicalTerminationId GET, "Recommendation X.721: 1992":operationalState GET, "Recommendation M.3100: 1992":supportedByObjectList GET; NOTIFICATIONS "Recommendation X.721: 1992":objectCreation, "Recommendation X.721: 1992":objectDeletion, "Recommendation X.721: 1992":stateChange, "Recommendation X.721: 1992":attributeValueChange;;; CONDITIONAL PACKAGES "Recommendation M.3100: 1992":tmnCommunicationsAlarmInformationPackage PRESENT IF "There are alarms associated with the timingPhysicalTermination", "Recommendation M.3100: 1992":alarmSeverityAssignmentPointerPackage PRESENT IF "an instance supports it"; REGISTERED AS { etsObjectClass 20 }; timingPhysicalTerminationSinkBehaviour BEHAVIOUR DEFINED AS "This managed object represents the external 2 MHz input interface (reference point T3 in the Recommendation G.783). This object class terminates (receives) the 2 MHz signal. The probable causes which are reported by a communicationsAlarm notification are lossOfSignal and degradedSignal."; timingPhysicalTerminationSource MANAGED OBJECT CLASS DERIVED FROM "Recommendation X.721: 1992": top; CHARACTERIZED BY timingPhysicalTerminationSourcePkg PACKAGE BEHAVIOUR timingPhysicalTerminationSourceBeh; ATTRIBUTES timingPhysicalTerminationId GET, "Recommendation X.721: 1992":operationalState GET, "Recommendation M.3100: 1992":supportedByObjectList GET, outputTimingSourcePointer GET; NOTIFICATIONS "Recommendation X.721: 1992":objectCreation, "Recommendation X.721: 1992":objectDeletion, "Recommendation X.721: 1992":stateChange, "Recommendation X.721: 1992":attributeValueChange;;; REGISTERED AS {etsObjectClass 21}; timingPhysicalTerminationSourceBeh BEHAVIOUR DEFINED AS "This managed object represents the external 2 MHz output interface (reference point T4 in the Recommendation G.783). This object class originates (transmits) the 2 MHz signal."; sSMActivePackage PACKAGE ATTRIBUTES sSMActive GET-REPLACE; REGISTERED AS { etsPackage 1 }; sSMQualityPackage PACKAGE ATTRIBUTES sSMQuality GET-REPLACE; REGISTERED AS { etsPackage 2 }; squelchStatusPkg PACKAGE ATTRIBUTES squelchStatus GET; REGISTERED AS { etsPackage 3 }; squelchThresholdsPkg PACKAGE ATTRIBUTES squelchT0Threshold GET-REPLACE, squelchT1Threshold GET-REPLACE; REGISTERED AS { etsPackage 4 }; supportedByObjectList The value of the supportedByObjectList attribute points to the equipment and software objects which implement the TPs. currentTimingSourcePointer ATTRIBUTE WITH ATTRIBUTE SYNTAX PrETS13.CurrentTimingSourcePointer; MATCHES FOR EQUALITY; REGISTERED AS {etsAttribute 10 }; outputTimingSourcePointer ATTRIBUTE WITH ATTRIBUTE SYNTAX PrETS13.OutputTimingSourcePointer; MATCHES FOR EQUALITY; REGISTERED AS {etsAttribute 14 }; poweredEquipmentPtrList ATTRIBUTE WITH ATTRIBUTE SYNTAX PrETS13.PoweredEquipmentPtrList; MATCHES FOR EQUALITY, SET-COMPARISON, SET-INTERSECTION; BEHAVIOUR poweredEquipmentPtrListBehaviour BEHAVIOUR DEFINED AS This attribute is used to point to the equipment object instances which are powered by a powerSupply instance. ;; REGISTERED AS {etsAttribute 11 }; powerSource ATTRIBUTE WITH ATTRIBUTE SYNTAX PrETS13.PowerSource ; MATCHES FOR EQUALITY; BEHAVIOUR powerSourceBehaviour BEHAVIOUR DEFINED AS This attribute is used to display the voltage of a power source. ;; REGISTERED AS { etsAttribute 9 }; powerSupplyId ATTRIBUTE WITH ATTRIBUTE SYNTAX PrETS13.NameType ; MATCHES FOR EQUALITY; BEHAVIOUR powerSupplyIdBehaviour BEHAVIOUR DEFINED AS This attribute is used as an RDN for naming instances of the powerSupply object classes. ;; REGISTERED AS { etsAttribute 8 }; sSMActive ATTRIBUTE WITH ATTRIBUTE SYNTAX PrETS13.Boolean; MATCHES FOR EQUALITY; BEHAVIOUR sSMActiveBehaviour BEHAVIOUR DEFINED AS "This attribute indicates whether or not the SSM algorithm is active(active = TRUE).";; REGISTERED AS { etsAttribute 15 }; sSMQuality ATTRIBUTE WITH ATTRIBUTE SYNTAX PrETS13.Integer; MATCHES FOR EQUALITY; BEHAVIOUR sSMQualityBehaviour BEHAVIOUR DEFINED AS "This attribute indicates the quality(0 to 15) of the timing source. Set operations on this attribute are not allowed for interfaces that carry quality information. When active, the SSM algorithm gives priority to the quality indications before considering priority indications attached to the protection units.";; REGISTERED AS { etsAttribute 16 }; squelchStatus ATTRIBUTE WITH ATTRIBUTE SYNTAX PrETS13.Boolean; MATCHES FOR EQUALITY; BEHAVIOUR squelchStatusBehaviour BEHAVIOUR DEFINED AS "This attribute indicates whether the selected input (either T0 or T1) to the T4 selection proces is squelched or not (squelched = TRUE).";; REGISTERED AS { etsAttribute 17 }; squelchT0Threshold ATTRIBUTE WITH ATTRIBUTE SYNTAX PrETS13.Integer; MATCHES FOR EQUALITY; BEHAVIOUR squelchT0ThresholdBehaviour BEHAVIOUR DEFINED AS "This attribute indicates the quality (0..15) of the T0 output below which the T0 output is squelched ";; REGISTERED AS { etsAttribute 18 }; squelchT1Threshold ATTRIBUTE WITH ATTRIBUTE SYNTAX PrETS13.Integer; MATCHES FOR EQUALITY; BEHAVIOUR squelchT1ThresholdBehaviour BEHAVIOUR DEFINED AS "This attribute indicates the quality (0..15) of the T1 reference selected by selector A below which the T1 reference is squelched ";; REGISTERED AS { etsAttribute 19 }; syncProtectionStatus ATTRIBUTE WITH ATTRIBUTE SYNTAX PrETS13.SyncProtectionStatus; MATCHES FOR EQUALITY, SET-COMPARISON, SET-INTERSECTION; BEHAVIOUR syncProtectionStatusBeh; REGISTERED AS { etsAttribute 20 }; syncProtectionStatusBeh BEHAVIOUR DEFINED AS "This attribute is used to indicate the status of the protection switch in a protectionUnit instance. The remainder of this behaviour provides the allowable syncProtectionStatus attribute values for protecting units. No Request: No request is present on the protecting unit. Manual Switch Complete to Protecting Unit: A Manual Switch has been completed to this protecting unit. Force Switch Complete to Protecting Unit: A Force Switch has been completed to this protecting unit. Automatic Switch Complete to Protecting Unit: An Automatic Switch has been completed to this protecting unit. Protecting Unit Failed: The protecting unit has a failure condition present. Protecting Unit Locked Out: The protecting unit has been locked out."; timingGeneratorId ATTRIBUTE WITH ATTRIBUTE SYNTAX PrETS13.NameType ; MATCHES FOR EQUALITY; BEHAVIOUR timingGeneratorIdBehaviour BEHAVIOUR DEFINED AS This attribute is used as an RDN for naming instances of the timingGenerator object classes. ;; REGISTERED AS { etsAttribute 22 }; timingPhysicalTerminationId ATTRIBUTE WITH ATTRIBUTE SYNTAX PrETS13.NameType; MATCHES FOR EQUALITY; BEHAVIOUR timingPhysicalTerminationIdBehaviour BEHAVIOUR DEFINED AS "The timingPhysicalTerminationId is an attribute type whose distinguished value can be used as an RDN when naming an instance of the timingPhysicalTermination object class.";; REGISTERED AS {etsAttribute 21 }; powerSupply-sdhNE NAME BINDING SUBORDINATE OBJECT CLASS powerSupply; NAMED BY SUPERIOR OBJECT CLASS "Recommendation G.774" : sdhNE; WITH ATTRIBUTE powerSupplyId; BEHAVIOUR powerSupply-sdhNEBehaviour BEHAVIOUR DEFINED AS The subordinate managed object is automatically instantiated when the superior managed object is instantiated, according to the make-up and mode of operation of the equipment. ;; REGISTERED AS { etsNameBinding 18 }; syncProtectionUnit-syncProtectionGroup NAME BINDING SUBORDINATE OBJECT CLASS syncProtectionUnit; NAMED BY SUPERIOR OBJECT CLASS syncProtectionGroup; WITH ATTRIBUTE "Recommendation G.774-03:1994":protectionUnitId; CREATE WITH-AUTOMATIC-INSTANCE-NAMING; DELETE ONLY-IF-NO-CONTAINED-OBJECTS; REGISTERED AS { etsNameBinding 26 }; timingGenerator-sdhNE NAME BINDING SUBORDINATE OBJECT CLASS timingGenerator; NAMED BY SUPERIOR OBJECT CLASS "Recommendation G.774":sdhNE; WITH ATTRIBUTE timingGeneratorId; BEHAVIOUR timingGenerator-sdhNEBehaviour BEHAVIOUR DEFINED AS The subordinate managed object is automatically instantiated when the superior managed object is instantiated, according to the make-up and mode of operation of the equipment. ;; REGISTERED AS { etsNameBinding 19 }; timingPhysicalTerminationBidirectional-sdhNE NAME BINDING SUBORDINATE OBJECT CLASS timingPhysicalTerminationBidirectional; NAMED BY SUPERIOR OBJECT CLASS "Recommendation G.774":sdhNE; WITH ATTRIBUTE timingPhysicalTerminationId; BEHAVIOUR timingPhysicalTerminationBidirectional-sdhNEBeh BEHAVIOUR DEFINED AS "The subordinate managed object is automatically instantiated when the superior managed object is instantiated, according to the make-up and mode of operation of the equipment.";; REGISTERED AS { etsNameBinding 27 }; timingPhysicalTerminationSink-sdhNE NAME BINDING SUBORDINATE OBJECT CLASS timingPhysicalTerminationSink; NAMED BY SUPERIOR OBJECT CLASS "Recommendation G.774":sdhNE; WITH ATTRIBUTE timingPhysicalTerminationId; BEHAVIOUR timingPhysicalTerminationSink-sdhNEBeh BEHAVIOUR DEFINED AS "The subordinate managed object is automatically instantiated when the superior managed object is instantiated, according to the make-up and mode of operation of the equipment.";; REGISTERED AS { etsNameBinding 28 }; timingPhysicalTerminationSource-sdhNE NAME BINDING SUBORDINATE OBJECT CLASS timingPhysicalTerminationSource; NAMED BY SUPERIOR OBJECT CLASS "Recommendation G.774":sdhNE; WITH ATTRIBUTE timingPhysicalTerminationId; BEHAVIOUR timingPhysicalTerminationSource-sdhNEBeh BEHAVIOUR DEFINED AS "The subordinate managed object is automatically instantiated when the superior managed object is instantiated, according to the make-up and mode of operation of the equipment.";; REGISTERED AS {etsNameBinding 29 }; syncProtectionStatusParameter PARAMETER CONTEXT EVENT-INFO; WITH SYNTAX PrETS13.SyncProtectionStatusParameter; BEHAVIOUR syncProtectionStatusParameterBeh; REGISTERED AS { etsParameter 2 }; syncProtectionStatusParameterBeh BEHAVIOUR DEFINED AS "This parameter is included in the additional info parameters of the protection switching reporting notification."; PrETS13 {ccitt(0) identified-organization(4) etsi(0) ets304(304) informationModel(0) asn1Module(2) prETS13(4)} DEFINITIONS IMPLICIT TAGS ::= BEGIN -- EXPORTS everything IMPORTS NameType FROM ASN1DefinedTypesModule {ccitt(0) recommendation(0) m(13) m3100(3100) informationModel(0) asn1Module(2) asn1DefinedTypesModule(0)} ObjectInstance FROM CMIP-1 {joint-iso-ccitt ms(9) cmip(1) modules(0) protocol(3) RelativeDistinguishedName}; Boolean ::= BOOLEAN CurrentTimingSourcePointer ::= CHOICE { pointer [0] ObjectInstance, internalOscillator [1] NULL } Integer ::= INTEGER OutputTimingSourcePointer ::= ObjectInstance PoweredEquipmentPtrList ::= SET OF ObjectInstance PowerSource ::= INTEGER SyncProtectionStatus ::= CHOICE { noRequest [0] NULL, autoSwitch [1] RelativeDistinguishedName, manualSwitch [2] RelativeDistinguishedName, forcedSwitch [3] RelativeDistinguishedName, lockout [4] NULL, failure [5] NULL } -- In the SyncProtectionStatus syntax, autoSwitch, manualSwitch and forcedSwitch will contain the RDN of the synchronisation protection unit which has been switched from. SyncProtectionStatusParameter ::= SEQUENCE { toProtectionStatus SyncProtectionStatus, fromProtectionStatus SyncProtectionStatus OPTIONAL} END