-- File Name : ThreeParMIB.mib -- -- Date : Sun Sept 01 12:00:00 PDT 2023 -- Revision : rev 1.16 -- - Added sysName varbind to trap OBJECT list which was missed previously -- -- Date : Sun Nov 20 12:00:00 PDT 2022 -- Revision : rev 1.15 -- - Added sysName varbind to alertNotify trap -- -- Date : Wed Jul 21 12:00:00 PDT 2019 -- Revision : rev 1.14 -- - added 'clear' to severity, only applicable if 'nodup' or 'all' is -- specified for addsnmpmgr -alertclear option -- -- Date : Wed Nov 01 12:00:00 PDT 2017 -- Revision : rev 1.13 -- - added managerIP OID -- -- Date : Thur Mar 16 12:00:00 PDT 2017 -- Revision : rev 1.12 -- - added storeServAlerts -- -- Date : Tue Oct 25 12:00:00 PDT 2016 -- Revision : rev 1.11 -- - added nodeCpuStatsTable, cpuStatsTable, and related table columns -- -- Date : Wed Aug 17 12:00:00 PDT 2016 -- Revision : rev 1.10 -- - Updated timeOccurred description -- -- Date : Tue May 24 13:00:00 PDT 2016 -- Revision : rev 1.9 -- - Rebranded company name from HP to HPE in Description fields -- -- Date : Tue Sep 18 10:00:00 PDT 2014 -- Revision : rev 1.8 -- - added catalogKey and detailedMessage to alertTable and alertNotify -- -- Date : Tue Mar 12 11:22:00 PDT 2013 -- Revision : rev 1.7 -- - added serialNumber to alertTable and alertNotify -- -- Date : Thur Aug 02 15:22:00 PDT 2012 -- Revision : rev 1.6 -- - Renamed this file from 3PAR-MIB.mib to ThreeParMIB.mib -- - Rebranded company name from 3PAR to HP 3PAR -- -- Date : Fri Oct 04 14:45:00 PDT 2010 -- Revision : rev 1.5 -- - Added new type Debug to Severity -- -- Date : Fri Oct 05 15:00:00 PDT 2007 -- Revision : rev 1.4 -- - Corrected company name to 3PAR in the ORGANIZATION and CONTACT -- -- Date : Mon Dec 13 17:00:00 PDT 2004 -- Revision : rev 1.3 -- - Added AGENT-CAPABILITIES statement to specify that -- sysName is read-only -- -- Date : Mon Dec 13 16:40:00 PDT 2004 -- Revision : rev 1.2 -- - Added id, messageCode and state to alertTable and alertNotify -- -- Date : Tue June 14 15:45:00 PDT 2004 -- Revision : rev 1.1 -- - 'inserv' is changed from OBJECT IDENTIFIER to -- OBJECT-IDENTITY -- - Defined ThreeparLongDisplayString for strings -- longer than 255 -- - Got rid of size specifications for DisplayString -- - Removed possibleCause and suggestedAction from -- alertNotify as they are neither used nor defined -- -- Date : Tue Jul 09 17:15:55 PDT 2002 -- Revision : rev 1.0 ThreeParMIB DEFINITIONS ::= BEGIN IMPORTS DisplayString, TEXTUAL-CONVENTION FROM SNMPv2-TC AGENT-CAPABILITIES, OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP FROM SNMPv2-CONF enterprises, MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, OBJECT-IDENTITY, Integer32, Unsigned32, Counter64 FROM SNMPv2-SMI; threepar MODULE-IDENTITY LAST-UPDATED "202308240629Z" ORGANIZATION "Organization : HPE 3PAR" CONTACT-INFO "Contact-info www.hpe.com/3PAR" DESCRIPTION "This file specifies management information interface for all HPE 3PAR, Primera, Alletra and GreenLake for Block Storage products. This information is normally used by any management software that utilizes SNMP as management standard. The SNMP agent inside the device provides the specified information." REVISION "202309010629Z" DESCRIPTION "rev 1.16 - Added sysName varbind to trap OBJECT list which was missed previously - Changed checkSnmpAlert OID" REVISION "202211202110Z" DESCRIPTION "rev 1.15 - Added sysName varbind to alertNotify trap" REVISION "201907211200Z" DESCRIPTION "rev 1.14 - Added clear to severity, only applicable if nodup or all is specified for addsnmpmgr -alertclear option" REVISION "201711011200Z" DESCRIPTION "rev 1.13 - Added managerIp OID" REVISION "201703161200Z" DESCRIPTION "rev 1.12 - Added storeServAlerts - Added compliance groups" REVISION "201612091200Z" DESCRIPTION "rev 1.11 - Added nodeCpuStatsTable and cpuStatsTable - Added tier and sparePartNumber to alertTable and alertNotify" REVISION "201608171200Z" DESCRIPTION "rev 1.10 - Updated timeOccurred description" REVISION "201605241300Z" DESCRIPTION "rev 1.9 - Rebranded company name from HP to HPE" REVISION "201409181000Z" DESCRIPTION "rev 1.8 - added catalogKey and detailedMessage to alertTable and alertNotify" REVISION "201303121122Z" DESCRIPTION "rev 1.7 - added serialNumber to alertTable and alertNotify" REVISION "201208021522Z" DESCRIPTION "rev 1.6 - Renamed this file from 3PAR-MIB.mib to ThreeParMIB.mib - Rebranded company name from 3PAR to HP 3PAR" REVISION "201010041445Z" DESCRIPTION "rev 1.5 - Added a new level to Severity" REVISION "200710051500Z" DESCRIPTION "rev 1.4 - Corrected company name to 3PAR in the ORGANIZATION and CONTACT" REVISION "200412131700Z" DESCRIPTION "rev 1.3 - Added AGENT-CAPABILITIES statement to specify that sysName is read-only" REVISION "200412131640Z" DESCRIPTION "rev 1.2 - Added id, messageCode and state to alertTable and alertNotify" REVISION "200406141545Z" DESCRIPTION "rev 1.1 - 'inserv' is changed from OBJECT IDENTIFIER to OBJECT-IDENTITY - Defined ThreeparLongDisplayString for strings longer than 255 - Got rid of size specifications for DisplayString - Removed possibleCause and suggestedAction from alertNotify as they are neither used nor defined" REVISION "200204161327Z" DESCRIPTION "rev 1.0" ::= { enterprises 12925 } ThreeparLongDisplayString ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Use this textual convention for display string that can be longer than 255 characters, since DisplayString is defined in SNMPv2-TC as having a maximum size of only 255. A size range will have to be specified when using this convention." SYNTAX OCTET STRING inserv OBJECT-IDENTITY STATUS current DESCRIPTION "InServ product" ::= { threepar 1 } inservConf OBJECT IDENTIFIER ::= { inserv 1 } inservGroups OBJECT IDENTIFIER ::= { inservConf 1 } inservCompls OBJECT IDENTIFIER ::= { inservConf 2 } inservEvents OBJECT IDENTIFIER ::= { inserv 2 } -- the inservGeneric group -- a collection of objects common to more than one area inservGeneric OBJECT IDENTIFIER ::= { inserv 3 } managerIp OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The IP address of the SNMP manager from which the SNMP authentication failure trap originated." ::= { inservGeneric 1 } -- agent capabilities inservAgentCaps OBJECT-IDENTITY STATUS current DESCRIPTION "InServ agent profile" ::= { inserv 4 } inservAgentCapability AGENT-CAPABILITIES PRODUCT-RELEASE "InServ Release 2.2" STATUS current DESCRIPTION "HPE 3PAR agent capability. Please note that the HPE 3PAR agent supports snmpObsoleteGroup in SNMPv2-MIB instead of snmpGroup." SUPPORTS SNMPv2-MIB INCLUDES { systemGroup } VARIATION sysName ACCESS read-only DESCRIPTION "System name is not configurable" ::= { inservAgentCaps 1 } inservAgentCapabilityV02 AGENT-CAPABILITIES PRODUCT-RELEASE "StoreServ Release 3.3.1 MU2" STATUS current DESCRIPTION "HPE 3PAR agent capability. Please note that the HPE 3PAR agent supports snmpObsoleteGroup in SNMPv2-MIB instead of snmpGroup." SUPPORTS SNMPv2-MIB INCLUDES { systemGroup, snmpTraps } VARIATION sysName ACCESS read-only DESCRIPTION "System name is not configurable" VARIATION authenticationFailure ACCESS read-only DESCRIPTION "managerIp is included as a varbind OBJECT in the trap to show who causes the failure." ::= { inservAgentCaps 2 } -- alertNotify -- contains groups for compliance alertNotifyGroups OBJECT IDENTIFIER ::= { inservGroups 1 } -- contains compliances alertNotifyCompliances OBJECT IDENTIFIER ::= { inservCompls 1 } -- alertTable alertTable OBJECT-TYPE SYNTAX SEQUENCE OF AlertEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Contains critical information in notifications sent to SNMP managers. This information is translated from alerts generated by the system." ::= { inserv 7 } alertEntry OBJECT-TYPE SYNTAX AlertEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Row Description" INDEX { index } ::= { alertTable 1 } AlertEntry ::= SEQUENCE { index Integer32, severity INTEGER, timeOccurred DisplayString, nodeID Unsigned32, component DisplayString, details ThreeparLongDisplayString, id Unsigned32, messageCode Unsigned32, state INTEGER, serialNumber DisplayString, catalogKey DisplayString, detailedMessage DisplayString, tier DisplayString, sparePartNumber DisplayString, sysName DisplayString } index OBJECT-TYPE SYNTAX Integer32 (1) MAX-ACCESS read-only STATUS current DESCRIPTION "Index to access entries in alert table. However, the table is empty most of the time because the entry is deleted after sending the trap" ::= { alertEntry 1 } severity OBJECT-TYPE SYNTAX INTEGER { fatal (0), critical (1), major (2), minor (3), degraded (4), info (5), debug (6), clear (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Severity of the alert. The enumeration is borrowed from Common Information Model (CIM): 0 - fatal: indicates an error occurred, but it's too late to take any actions; 1 - critical: an action is needed immediately and scope of the error is broad; 2 - major: an action is needed, the situation is serious; 3 - minor: an action is needed, but the situation is not serious; 4 - degraded/warning: the user decides whether to take an action; 5 - informational: indicates state change or status change, but it's not an error; 6 - debug: information that are logged for later analysis; 7- clear: indicates that the alert is cleared either by the system or by an admin marking it acked or fixed, applicable only if addsnmpmgr -alertclear option is 'nodup' or 'all'." ::= { alertEntry 2 } timeOccurred OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The local time and date when the alert occurred. The format is '%Y-%m-%d %H:%M:%S %Z'. Where: %Y - year including century, %m - two digit month, %d - two digit day of month, %H - two digit hour, %M - two digit minute, %S - two digit second, %Z - timezone name or abbreviation or no characters if timezone cannot be determined." ::= { alertEntry 3 } nodeID OBJECT-TYPE SYNTAX Unsigned32 ( 0 .. 31 ) MAX-ACCESS read-only STATUS current DESCRIPTION "The node the alert was posted on. The node number starts from 0. The maximum number of node is 32." ::= { alertEntry 4 } component OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The component which the event applies to; for example, power supply, SCSI disk, BIOS, cage etc..." DEFVAL { "1" } ::= { alertEntry 5 } details OBJECT-TYPE SYNTAX ThreeparLongDisplayString (SIZE(0..511)) MAX-ACCESS read-only STATUS current DESCRIPTION "Additional detailed description of the alert. The detail may include things like disk number, cage number the alert applies to." ::= { alertEntry 6 } id OBJECT-TYPE SYNTAX Unsigned32 ( 1 .. 4294967295 ) MAX-ACCESS read-only STATUS current DESCRIPTION "Unique ID that identifies the instance of an alert. This is a unique number that is generated each time an alert is generated by the system." ::= { alertEntry 7 } messageCode OBJECT-TYPE SYNTAX Unsigned32 ( 65537 .. 4294967295 ) MAX-ACCESS read-only STATUS current DESCRIPTION "Message code is assigned to a particular event type, and is encoded as a 32-bit number in the following way: The MSB 8 bits are reserved. The next 8 bits represent a particular subsystem or component. The LSB 16 bits are the keycode id within the subsystem. For example, Remote Copy Target Down event has a subsystem ID of 37 (remote copy subsystem), and a keycode ID of 1, thus the message code for this event = ((37 << 16) | 1) = 0x250001 = 2424833. This is shown as 'Message Code' in the CLI 'showalert' display, and also shows up in the Alerts Details Pane in the GUI." ::= { alertEntry 8 } state OBJECT-TYPE SYNTAX INTEGER { undefined (0), new (1), acknowledged (2), fixed (3), removed (4), autofixed (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "This provides information about the state of the alert. new - new alert generated by the system acknowledged - an administrator has acknowledged the alert but may or may not have fixed it, depending on whether remedial action is necessary fixed - remedial action has been taken to fix the alert condition removed - the alert has been removed autofixed - the system has taken action to automatically resolve the alert condition." ::= { alertEntry 9 } serialNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The serial-number of the HPE 3PAR InServ system" ::= { alertEntry 10 } catalogKey OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The extension of the message code. It's used for the lookup of HPGT information." ::= { alertEntry 11 } detailedMessage OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The extension of the details. It provides more specific details of error condition." ::= { alertEntry 12 } tier OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The event tier. It provides more details on the type of event." ::= { alertEntry 13 } sparePartNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The spare part number from events in the Hardware replacement or Hardware check tiers." ::= { alertEntry 14 } sysName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the storage system." ::= { alertEntry 15 } -- alertNofify alertNotify NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, catalogKey, detailedMessage, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Alert notification contains details about an event that may affect system operations and performance. The details include all columns defined in alertTable." ::= { inserv 8 } -- alertNotify compliance alertNotifyGroup OBJECT-GROUP OBJECTS { index, component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, catalogKey, detailedMessage, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "alertTable columns representing details about an event that may affect system operations and performance." ::= { alertNotifyGroups 1 } alertNotifyEventsGroup NOTIFICATION-GROUP NOTIFICATIONS { alertNotify } STATUS current DESCRIPTION "Contains alertNotify events for system alerts." ::= { alertNotifyGroups 2 } alertNotifyCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "A collection of objects providing basic notifications for a HPE 3PAR server." MODULE MANDATORY-GROUPS { alertNotifyGroup, alertNotifyEventsGroup } ::= { alertNotifyCompliances 1 } -- cpu Stats MIB cpuStatsMIB OBJECT IDENTIFIER ::= { inserv 9 } -- contains cpu stat groups for compliance cpuStatsComplianceGroups OBJECT IDENTIFIER ::= { cpuStatsMIB 1 } -- contains compliances cpuStatsCompliances OBJECT IDENTIFIER ::= { cpuStatsMIB 2 } -- contains functional areas for cpu stats cpuStatsObjs OBJECT IDENTIFIER ::= { cpuStatsMIB 3 } -- nodeCpuStatsTable - overall CPU related statistics for each node in a StoreServe nodeCpuStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF NodeCpuStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The nodeCpuStatsTable contains overall CPU related statistics for each node in a HPE 3PAR StoreServe system." ::= { cpuStatsObjs 1 } nodeCpuStatsEntry OBJECT-TYPE SYNTAX NodeCpuStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the nodeCpuStatsTable." INDEX { nodeCpuStatsIndex } ::= { nodeCpuStatsTable 1 } NodeCpuStatsEntry ::= SEQUENCE { nodeCpuStatsIndex Unsigned32, nodeCpuStatsNs Counter64, nodeCpuStatsNumCpus Unsigned32, nodeCpuStatsInterupts Counter64, nodeCpuStatsContextSwitches Counter64, nodeCpuStatsBootTime Counter64, nodeCpuStatsProcs Counter64 } -- columns from nodeCpuStatsTable nodeCpuStatsIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "3PAR Node ID plus 1." ::= { nodeCpuStatsEntry 1 } nodeCpuStatsNs OBJECT-TYPE SYNTAX Counter64 UNITS "nanoseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "Node nano seconds when stats were read." ::= { nodeCpuStatsEntry 2 } nodeCpuStatsNumCpus OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of CPUs in the node. " ::= { nodeCpuStatsEntry 3 } nodeCpuStatsInterupts OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of interrupts serviced on the node since boot time." ::= { nodeCpuStatsEntry 4 } nodeCpuStatsContextSwitches OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of context switches across all CPUs on the node since boot time." ::= { nodeCpuStatsEntry 5 } nodeCpuStatsBootTime OBJECT-TYPE SYNTAX Counter64 UNITS "seconds" MAX-ACCESS read-only STATUS current DESCRIPTION "Time in the epoch when the node was booted. The epoch started at midnight on January 1 1970 UTC." ::= { nodeCpuStatsEntry 6 } nodeCpuStatsProcs OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of processes created since the node was booted." ::= { nodeCpuStatsEntry 7 } -- cpuStatsTable - statistics for each CPU in a node in a StoreServe cpuStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF CpuStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The cpuStatsTable contains statistics for each CPU in a node in a HPE 3PAR StoreServe system." ::= { cpuStatsObjs 2 } cpuStatsEntry OBJECT-TYPE SYNTAX CpuStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the cpuStatsTable." INDEX { nodeCpuStatsIndex, cpuStatsIndex } ::= { cpuStatsTable 1 } CpuStatsEntry ::= SEQUENCE { cpuStatsIndex Unsigned32, cpuStatsUser Counter64, cpuStatsSys Counter64, cpuStatsIdle Counter64, cpuStatsNodeNs Counter64 } -- columns from cpuStatsTable cpuStatsIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index of the CPU starting at 1." ::= { cpuStatsEntry 1 } cpuStatsUser OBJECT-TYPE SYNTAX Counter64 UNITS "ticks" MAX-ACCESS read-only STATUS current DESCRIPTION "Total time spent executing user processes on the cpu since the node booted." ::= { cpuStatsEntry 2 } cpuStatsSys OBJECT-TYPE SYNTAX Counter64 UNITS "ticks" MAX-ACCESS read-only STATUS current DESCRIPTION "Total time spend executing system threads on the cpu since the node booted." ::= { cpuStatsEntry 3 } cpuStatsIdle OBJECT-TYPE SYNTAX Counter64 UNITS "ticks" MAX-ACCESS read-only STATUS current DESCRIPTION "Total idle time on the cpu since the node booted." ::= { cpuStatsEntry 4 } cpuStatsNodeNs OBJECT-TYPE SYNTAX Counter64 UNITS "nanoseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "Node nano seconds when stats were read." ::= { cpuStatsEntry 5 } -- cpu stats compliance nodeCpuStatsGroup OBJECT-GROUP OBJECTS { nodeCpuStatsNs, nodeCpuStatsNumCpus, nodeCpuStatsInterupts, nodeCpuStatsContextSwitches, nodeCpuStatsBootTime, nodeCpuStatsProcs } STATUS current DESCRIPTION "nodeCpuStatsTable columns representing the overall cpu statistics for each node" ::= { cpuStatsComplianceGroups 1 } cpuStatsGroup OBJECT-GROUP OBJECTS { cpuStatsUser, cpuStatsSys, cpuStatsIdle, cpuStatsNodeNs } STATUS current DESCRIPTION "cpuStatsTable columns representing the statistics for each cpu in a node" ::= { cpuStatsComplianceGroups 2 } cpuStatsCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "A collection of objects providing basic instrumentation for a HPE 3PAR server." MODULE MANDATORY-GROUPS { nodeCpuStatsGroup, cpuStatsGroup } ::= { cpuStatsCompliances 1 } -- storeServAlerts -- contains groups for compliance storeServAlertsGroups OBJECT IDENTIFIER ::= { inservGroups 2 } -- contains compliances storeServAlertsCompliances OBJECT IDENTIFIER ::= { inservCompls 2 } -- object definitions storeServAlerts OBJECT-IDENTITY STATUS current DESCRIPTION "Named alerts with descriptions" ::= { inservEvents 0 } activeVlunLimitExceeded NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "There are currently active VLUNs, which is above the supported limit of active VLUNs" ::= { storeServAlerts 1 } fcPortError NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Port Failed (Shutdown Due To Too Many Firmware Cores)." ::= { storeServAlerts 2 } portDeviceCountExceeded NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "[[sw_port]], supported device count exceeded for port." ::= { storeServAlerts 3 } diskPortHasExceededIoErrorThreshold NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Disk [[sw_port]] has exceeded a threshold tracking IO errors. errors have been seen in one hour." ::= { storeServAlerts 4 } componentStateChangeTargetModePortWentOffline NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Target Mode Port Went Offline; Port :: Degraded ()" ::= { storeServAlerts 5 } componentStateChangeTooManyInitiators NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Too many initiators; Port :: Degraded ()" ::= { storeServAlerts 6 } metadataInconsistencyInAVv NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "[[vvol]] Volume not started due to metadata inconsistency; manual check required." ::= { storeServAlerts 7 } vlmapCountExceedsThreshold NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "VV () exceeds vlmap count threshold 80% : AR1 AR5 AR5_SEC USR " ::= { storeServAlerts 8 } flashcachePerformanceDegradation NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Flash Cache I/O times are slow on node: ." ::= { storeServAlerts 9 } metadataInconsistencyInADeduplicationGroup NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION " Deduplication Group not started due to metadata inconsistency; manual check required." ::= { storeServAlerts 10 } vvUnrecoveredDifError NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Data Integrity Field (DIF) detected inconsistency for [[vvol]]" ::= { storeServAlerts 11 } componentStateChangeMaintenanceCheckRequired NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Maintenance Check Required; Virtual Volume () Degraded ()" ::= { storeServAlerts 12 } componentStateChangeLdsNotStarted NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "LDs Not Started; Virtual Volume () Failed ()" ::= { storeServAlerts 13 } componentStateChangeCopyFailed NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Copy Failed; Virtual Volume () Failed ()" ::= { storeServAlerts 14 } componentStateChangeSnapdataInvalid NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Snapdata Invalid; Virtual Volume () Failed ()" ::= { storeServAlerts 15 } componentStateChangeInternalConsistencyError NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Internal Consistency Error; Virtual Volume () Failed ()" ::= { storeServAlerts 16 } componentStateChangeNeedsToBeChecked NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Needs To Be Checked; Virtual Volume () Failed ()" ::= { storeServAlerts 17 } componentStateChangePreserved NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Preserved; Virtual Volume () Failed ()" ::= { storeServAlerts 18 } componentStateChangeInvalid NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Invalid; Virtual Volume () Failed ()" ::= { storeServAlerts 19 } componentStateChangeStale NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Stale; Virtual Volume () Failed ()" ::= { storeServAlerts 20 } ldskHasFailedSet NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "LD () row set failed. Internal reason ." ::= { storeServAlerts 21 } ldAvailabilityHasReduced NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Some Logical Disks (LDs) in the system are running with reduced availability." ::= { storeServAlerts 22 } logLdRaidSetFailure NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Log [[ld]] has a failed raid set: . Reason ." ::= { storeServAlerts 23 } diskMonitorStopped NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "pd wwn has failed for too long. Disk monitoring has stopped on this disk." ::= { storeServAlerts 24 } systemReporterPdPerformanceMajorAlert NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "System Reporter threshold alert with condition has been satisfied by pd with value(s) ." ::= { storeServAlerts 25 } systemOvertemp NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "System shutdown for over temp PDs, TOC quorum loss - TOC drives are at or above their spin down temperatures." ::= { storeServAlerts 26 } diskOvertempButNotSpundown NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Physical Disk (PD) with World Wide Name (WWN) has exceeded its temperature threshold ( C, limit C) but it could not be spundown. Location (::)." ::= { storeServAlerts 27 } diskOvertempAndSpundown NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Physical Disk (PD) with World Wide Name (WWN) has exceeded its temperature threshold ( C, limit C) and it has been spundown. Location (::)." ::= { storeServAlerts 28 } diskOvertempButNotSpundownNoDsk NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Physical Disk with World Wide Name (WWN) has exceeded its temperature threshold ( C, limit C) but it could not be spundown. Location (::)." ::= { storeServAlerts 29 } diskOvertempAndSpundownNoDsk NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Physical Disk with World Wide Name (WWN) has exceeded its temperature threshold ( C, limit C) and it has been spundown. Location (::)." ::= { storeServAlerts 30 } componentStateChangeFailedHardware0x00600deX153 NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Failed Hardware; Magazine Physical Disk Degraded ()" ::= { storeServAlerts 31 } componentStateChangeMediaFailed0x00600deX156 NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Media Failed; Magazine Physical Disk Degraded ()" ::= { storeServAlerts 32 } componentStateChangeFailedHardware0x00600faX153 NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Failed Hardware; Magazine Physical Disk Failed ()" ::= { storeServAlerts 33 } componentStateChangeMediaFailed0x00600faX156 NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Media Failed; Magazine Physical Disk Failed ()" ::= { storeServAlerts 34 } componentStateChangeReplaceDrive0x00600faX70 NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Replace Drive; Magazine Physical Disk Failed ()" ::= { storeServAlerts 35 } doubleNodeFailure NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "System is not able to recover from double node failure." ::= { storeServAlerts 36 } nodeRecoveryPowerfailEvent NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Node recovery requires a powerfail to continue" ::= { storeServAlerts 37 } licenseKeyUsageLicenseExpired NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "License feature has expired. You are in violation of your 3PAR License Agreement." ::= { storeServAlerts 38 } systemRecoveryNotificationAboutBadVolume NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Powerfail recovery could not be performed for volume with id . This may have caused loss of data for that volume. Use checkvv to check and fix the volume metadata consistency." ::= { storeServAlerts 39 } batteryStates NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Battery states could not be read from the configuration file. System cache is disabled." ::= { storeServAlerts 40 } systemRecoveryStalledDueToUnstartedVvs NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "System recovery stalled due to unstarted vvs. Num vvs: ." ::= { storeServAlerts 41 } unexpectedEncryptionStateOnNodeDrive NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "System is waiting for the encryption state of nodes to become valid. If this state persists, check existing alerts for more information." ::= { storeServAlerts 42 } ideDiskErrorNodeShutdown NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Node is being shutdown by the system because it had internal drive errors." ::= { storeServAlerts 43 } ideDiskErrorNodeNotShutdown NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Node is not being shutdown by the system even though there are internal drive errors because it is the last node left alive." ::= { storeServAlerts 44 } ideDiskErrorNodeNotShutdownLdsCannotBeServed NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Node is not being shutdown by the system even though there are internal drive errors because some LDs cannot be served by the remaining nodes." ::= { storeServAlerts 45 } ideDiskErrorNodeReboot NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Node is being rebooted by the system because it had internal drive errors." ::= { storeServAlerts 46 } authenticationFailure NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION " authentication failures in secs" ::= { storeServAlerts 47 } nodeIsOffline NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Node is offline" ::= { storeServAlerts 48 } memoryUsageInformation NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Memory usage critical: MemTotal: K MemFree: K Buffers: K Cached: K SwapCached: K Active: K Inactive: K SwapTotal: K SwapFree: K Dirty: K Writeback: K AnonPages: K Mapped: K Slab: K PageTables: K VmallocTotal: K VmallocUsed: K VmallocChunk: K NFS_Unstable: K Bounce: K CommitLimit: K Commited_AS: K." ::= { storeServAlerts 49 } clusterThermalShutdown NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Node , due to high temperature conditions, the storage system is being shutdown." ::= { storeServAlerts 50 } nodeNeedsToShutdown NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "THERMAL SHUTDOWN, node: " ::= { storeServAlerts 51 } slabMemoryUsageOverLimit NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "SlabUsage:: critical status= Totals:: memory=KB count= activeCount= largestUseSlabs(count=)::." ::= { storeServAlerts 52 } systemReporterCmpPerformanceMajorAlert NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "System Reporter threshold alert with condition has been satisfied by cmp on node with value(s) ." ::= { storeServAlerts 53 } systemReporterCpuPerformanceMajorAlert NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "System Reporter threshold alert with condition has been satisfied by cpu on node with value(s) ." ::= { storeServAlerts 54 } systemReporterLinkPerformanceMajorAlert NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "System Reporter threshold alert with condition has been satisfied by link on node with value(s) ." ::= { storeServAlerts 55 } cmpThreshold NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "CMP usage on node [[hw_node]] has exceeded %." ::= { storeServAlerts 56 } systemReporterCachePerformanceMajorAlert NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "System Reporter threshold alert with condition has been satisfied by cache on node with value(s) ." ::= { storeServAlerts 57 } componentStateChangeTimeOfDayBatteryFailure NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Time-Of-Day Battery Failure; Node Degraded ()" ::= { storeServAlerts 58 } componentStateChangeCpuOverheating NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "CPU Overheating; Node Degraded ()" ::= { storeServAlerts 59 } componentStateChangeNodeOfflineDueToFailure0x01a00deX13 NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Node Offline Due to Failure; Node Degraded ()" ::= { storeServAlerts 60 } componentStateChangeCpuDead0x01a00deX19 NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "CPU Dead; Node Degraded ()" ::= { storeServAlerts 61 } componentStateChangeNodeFanModule0Failed0x01a00deX25 NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Node Fan Module 0 Failed; Node Degraded ()" ::= { storeServAlerts 62 } componentStateChangeNodeFanModule0PowerFault0x01a00deX28 NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Node Fan Module 0 Power Fault; Node Degraded ()" ::= { storeServAlerts 63 } componentStateChangeNodeFanModule0UnderLimit NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Node Fan Module 0 Under Limit; Node Degraded ()" ::= { storeServAlerts 64 } componentStateChangeNodeThermalState NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Node Thermal State; Node Degraded ()" ::= { storeServAlerts 65 } componentStateChangeNodeFanModule1Failed0x01a00deX33 NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Node Fan Module 1 Failed; Node Degraded ()" ::= { storeServAlerts 66 } componentStateChangeNodeFanModule1PowerFault0x01a00deX35 NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Node Fan Module 1 Power Fault; Node Degraded ()" ::= { storeServAlerts 67 } componentStateChangeNodeOfflineDueToFailure0x01a00faX13 NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Node Offline Due to Failure; Node Failed ()" ::= { storeServAlerts 68 } componentStateChangeCpuDead0x01a00faX19 NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "CPU Dead; Node Failed ()" ::= { storeServAlerts 69 } componentStateChangeNodeFanModule0Failed0x01a00faX25 NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Node Fan Module 0 Failed; Node Failed ()" ::= { storeServAlerts 70 } componentStateChangeNodeFanModule0PowerFault0x01a00faX28 NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Node Fan Module 0 Power Fault; Node Failed ()" ::= { storeServAlerts 71 } componentStateChangeUncorrectableMemoryError NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Uncorrectable Memory Error; Node Failed ()" ::= { storeServAlerts 72 } componentStateChangeNodeThermalShutdown NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Node Thermal Shutdown; Node Failed ()" ::= { storeServAlerts 73 } componentStateChangeNodeFanModule1Failed0x01a00faX33 NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Node Fan Module 1 Failed; Node Failed ()" ::= { storeServAlerts 74 } componentStateChangeNodeFanModule1PowerFault0x01a00faX35 NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Node Fan Module 1 Power Fault; Node Failed ()" ::= { storeServAlerts 75 } componentStateChangeMultipleUncorrectableMemoryError NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Multiple Uncorrectable Memory Error; Node Failed ()" ::= { storeServAlerts 76 } componentStateChangeDcFailed0x01b00faX1 NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "DC Failed; Node Power Supply Failed ()" ::= { storeServAlerts 77 } componentStateChangeOverTemperature NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Over Temperature; Node Power Supply Failed ()" ::= { storeServAlerts 78 } componentStateChangeAcFailed NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "AC Failed; Node Power Supply Failed ()" ::= { storeServAlerts 79 } componentStateChangeFanFailed0x01b00faX3 NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Fan Failed; Node Power Supply Failed ()" ::= { storeServAlerts 80 } componentStateChangeTemperatureUnderWarningThreshold0x01e00deX1 NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Temperature Under Warning Threshold; Cage Degraded ()" ::= { storeServAlerts 81 } componentStateChangeOperatorsPanelFailed NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Operators Panel Failed; Cage Degraded ()" ::= { storeServAlerts 82 } componentStateChangeOperatorsPanelWarning NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Operators Panel Warning; Cage Degraded ()" ::= { storeServAlerts 83 } componentStateChangeUnsupportedCage NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Unsupported Cage; Cage Degraded ()" ::= { storeServAlerts 84 } componentStateChangeTemperatureUnderWarningThreshold0x01e00faX1 NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Temperature Under Warning Threshold; Cage Failed ()" ::= { storeServAlerts 85 } componentStateChangeTemperatureUnderFailureThreshold NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Temperature Under Failure Threshold; Cage Failed ()" ::= { storeServAlerts 86 } componentStateChangeTemperatureOverWarningThreshold NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Temperature Over Warning Threshold; Cage Failed ()" ::= { storeServAlerts 87 } componentStateChangeInaccessible NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Inaccessible; Cage Failed ()" ::= { storeServAlerts 88 } componentStateChangeTemperatureOverFailureThreshold NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Temperature Over Failure Threshold; Cage Failed ()" ::= { storeServAlerts 89 } componentStateChangePortBypassed NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Port Bypassed; Disk Degraded ()" ::= { storeServAlerts 90 } componentStateChangeNotready NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Notready; Disk Degraded ()" ::= { storeServAlerts 91 } componentStateChangeMissing0x01f00deX129 NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Missing; Disk Degraded ()" ::= { storeServAlerts 92 } componentStateChangeInvalidConnections NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Invalid connections; Disk Degraded ()" ::= { storeServAlerts 93 } componentStateChangeNotAvailableForAllocations NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Not Available For Allocations; Disk Degraded ()" ::= { storeServAlerts 94 } componentStateChangeOldFirmware NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Old Firmware; Disk Degraded ()" ::= { storeServAlerts 95 } componentStateChangeDisabledAPort NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Disabled A Port; Disk Degraded ()" ::= { storeServAlerts 96 } componentStateChangeMissingAPort NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Missing A Port; Disk Degraded ()" ::= { storeServAlerts 97 } componentStateChangeErrorsOnAPort NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Errors on A Port; Disk Degraded ()" ::= { storeServAlerts 98 } componentStateChangeProlongedMissingAPort NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Prolonged Missing A Port; Disk Degraded ()" ::= { storeServAlerts 99 } componentStateChangeDisabledBPort NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Disabled B Port; Disk Degraded ()" ::= { storeServAlerts 100 } componentStateChangeMissingBPort NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Missing B Port; Disk Degraded ()" ::= { storeServAlerts 101 } componentStateChangeErrorsOnBPort NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Errors on B Port; Disk Degraded ()" ::= { storeServAlerts 102 } componentStateChangeProlongedMissingBPort NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Prolonged Missing B Port; Disk Degraded ()" ::= { storeServAlerts 103 } componentStateChangeOverTemperatureWarning NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Over Temperature Warning; Disk Degraded ()" ::= { storeServAlerts 104 } componentStateChangeOverTemperatureAlert NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Over Temperature Alert; Disk Degraded ()" ::= { storeServAlerts 105 } componentStateChangeInvalidMedia NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Invalid Media; Disk Degraded ()" ::= { storeServAlerts 106 } componentStateChangeFailedHardware0x01f00deX153 NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Failed Hardware; Disk Degraded ()" ::= { storeServAlerts 107 } componentStateChangeSmartThresholdExceeded NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Smart Threshold Exceeded; Disk Degraded ()" ::= { storeServAlerts 108 } componentStateChangeMultipleChunkletsMediaBad NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Multiple Chunklets Media Bad; Disk Degraded ()" ::= { storeServAlerts 109 } componentStateChangeMediaFailed0x01f00deX156 NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Media Failed; Disk Degraded ()" ::= { storeServAlerts 110 } componentStateChangeIncreasedErrorCount NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Increased Error Count; Disk Degraded ()" ::= { storeServAlerts 111 } componentStateChangeDifThresholdExceeded NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "DIF Threshold Exceeded; Disk Degraded ()" ::= { storeServAlerts 112 } componentStateChangeProlongedNotReady NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Prolonged Not Ready; Disk Degraded ()" ::= { storeServAlerts 113 } componentStateChangeNoValidPorts NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "No Valid Ports; Disk Degraded ()" ::= { storeServAlerts 114 } componentStateChangeInquiryFailed NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Inquiry Failed; Disk Degraded ()" ::= { storeServAlerts 115 } componentStateChangeUnitReadyFailed NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Unit Ready Failed; Disk Degraded ()" ::= { storeServAlerts 116 } componentStateChangeReadCapacityFailed NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Read Capacity Failed; Disk Degraded ()" ::= { storeServAlerts 117 } componentStateChangeWriteLabelFailed NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Write Label Failed; Disk Degraded ()" ::= { storeServAlerts 118 } componentStateChangeModePageUpdateFailed NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Mode Page Update Failed; Magazine Physical Disk Degraded ()" ::= { storeServAlerts 119 } componentStateChangeReadLabelFailed NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Read Label Failed; Disk Degraded ()" ::= { storeServAlerts 120 } componentStateChangeMediumFormatCorrupted NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Medium Format Corrupted; Disk Degraded ()" ::= { storeServAlerts 121 } componentStateChangeLowWearLevelRemaining NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Low Wear Level Remaining; Disk Degraded ()" ::= { storeServAlerts 122 } componentStateChangeMiscompare NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Miscompare; Disk Degraded ()" ::= { storeServAlerts 123 } componentStateChangeInvalidCage NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Invalid Cage; Disk Degraded ()" ::= { storeServAlerts 124 } componentStateChangeSlowDrive NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Slow Drive; Disk Degraded ()" ::= { storeServAlerts 125 } componentStateChangeServicing NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Servicing; Disk Degraded ()" ::= { storeServAlerts 126 } componentStateChangeDriveErrorBitSet NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Drive Error Bit Set; Disk Degraded ()" ::= { storeServAlerts 127 } componentStateChangeFailedHardware0x01f00faX153 NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Failed Hardware; Disk Failed ()" ::= { storeServAlerts 128 } componentStateChangeMediaFailed0x01f00faX156 NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Media Failed; Disk Failed ()" ::= { storeServAlerts 129 } componentStateChangeReplaceDrive0x01f00faX70 NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Replace Drive; Disk Failed ()" ::= { storeServAlerts 130 } internalErrorInAuthenticationLibrary NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Authentication internal error. Client address port " ::= { storeServAlerts 131 } assertBatteryFail NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Node PS Battery : Battery Failed during battery test." ::= { storeServAlerts 132 } componentStateChangeExpired NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Expired; Node [Power Supply ] Battery Degraded ()" ::= { storeServAlerts 133 } componentStateChangeChargingFailed NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Charging Failed; Node [Power Supply ] Battery Degraded ()" ::= { storeServAlerts 134 } componentStateChangeInternalError NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Internal Error; Node [Power Supply ] Battery Degraded ()" ::= { storeServAlerts 135 } componentStateChangeLoadSharingFailed NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Load Sharing Failed; Node [Power Supply ] Battery Degraded ()" ::= { storeServAlerts 136 } componentStateChangeFanFailed0x02200deX6 NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Fan Failed; Node [Power Supply ] Battery Degraded ()" ::= { storeServAlerts 137 } componentStateChangeDcFailed0x02200deX7 NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "DC Failed; Node [Power Supply ] Battery Degraded ()" ::= { storeServAlerts 138 } componentStateChangeChargerFailed NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Charger Failed; Node [Power Supply ] Battery Degraded ()" ::= { storeServAlerts 139 } componentStateChangeFailed NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Failed; Node [Power Supply ] Battery Failed ()" ::= { storeServAlerts 140 } portShutdownOnFatalError NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Port shut down: " ::= { storeServAlerts 141 } hostPortIsDown NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Host port (::) is down ()" ::= { storeServAlerts 142 } remoteCopyLinkStatus NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "The Remote Copy link has changed its status to " ::= { storeServAlerts 143 } replicationResourceUsageExceededGroupLogging NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Remote copy group with ID has transitioned to logging mode due to resource limitations." ::= { storeServAlerts 144 } replicationResourceUsageExceededGroupStopped NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Remote copy group with ID has been stopped due to resource limitations." ::= { storeServAlerts 145 } replicationResourcesRestoredGroupTransitionFromLoggingFailur NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Remote copy group with ID could not transition out of logging state when replication resources became available, retrying." ::= { storeServAlerts 146 } noAdminNetworkInterfaceDiscovered NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "The administrative network interface has failed on node [[hw_node]]. The system cannot be managed from this node." ::= { storeServAlerts 147 } tpVvAllocationSizeLimit NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Thin provisioned VV has reached reserved allocation of G (% of G)" ::= { storeServAlerts 148 } snapshotSpaceAllocationSizeLimit NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Reserved snapshot space for VV has reached allocation of G (% of G)" ::= { storeServAlerts 149 } cpgGrowthLimit NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "CPG SA space has reached allocation of G." ::= { storeServAlerts 150 } tpVvAllocationFailure NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Thin provisioned VV allocate space from CPG " ::= { storeServAlerts 151 } snapshotSpaceAllocationFailure NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Snapshot space for VV allocate space from CPG " ::= { storeServAlerts 152 } fcRawSpaceAllocation75Alert NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Total raw space usage at (above <75>% of total )" ::= { storeServAlerts 153 } fcRawSpaceAllocation85Alert NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Total raw space usage at (above <85>% of total )" ::= { storeServAlerts 154 } fcRawSpaceAllocation95Alert NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Total raw space usage at (above <95>% of total )" ::= { storeServAlerts 155 } nlRawSpaceAllocation75Alert NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Total raw space usage at (above <75>% of total )" ::= { storeServAlerts 156 } nlRawSpaceAllocation85Alert NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Total raw space usage at (above <85>% of total )" ::= { storeServAlerts 157 } nlRawSpaceAllocation95Alert NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Total raw space usage at (above <95>% of total )" ::= { storeServAlerts 158 } ssdRawSpaceAllocation75Alert NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Total raw space usage at (above <75>% of total )" ::= { storeServAlerts 159 } ssdRawSpaceAllocation85Alert NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Total raw space usage at (above <85>% of total )" ::= { storeServAlerts 160 } ssdRawSpaceAllocation95Alert NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Total raw space usage at (above <95>% of total )" ::= { storeServAlerts 161 } preservedDataLdsAreFull NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Preserved data LDs are full. No more preserved data can be handled." ::= { storeServAlerts 162 } componentStateChangePowerSupplyFanWarning NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Power Supply Fan Warning; Cage Power Supply Degraded ()" ::= { storeServAlerts 163 } componentStateChangePowerSupplyOff NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Power Supply Off; Cage Power Supply Degraded ()" ::= { storeServAlerts 164 } componentStateChangePowerSupplyFailed0x02b00faX1 NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Power Supply Failed; Cage Power Supply Failed ()" ::= { storeServAlerts 165 } componentStateChangePowerSupplyFailed0x02b00faX1026 NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Power Supply Failed; Cage Power Supply Failed ()" ::= { storeServAlerts 166 } componentStateChangePowerSupplyWarning NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Power Supply Warning; Cage Power Supply Failed ()" ::= { storeServAlerts 167 } componentStateChangePowerSupplyFanNotPresent NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Power Supply Fan Not Present; Cage Power Supply Failed ()" ::= { storeServAlerts 168 } componentStateChangePowerSupplyFanNotAvailable NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Power Supply Fan Not Available; Cage Power Supply Failed ()" ::= { storeServAlerts 169 } componentStateChangePowerSupplyNotAvailable NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Power Supply Not Available; Cage Power Supply Failed ()" ::= { storeServAlerts 170 } componentStateChangePowerSupplyAcFailed NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Power Supply AC Failed; Cage Power Supply Failed ()" ::= { storeServAlerts 171 } componentStateChangeInterfaceCardFailed0x02d00deX1026 NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Interface Card Failed; Cage Interface Card Degraded ()" ::= { storeServAlerts 172 } componentStateChangeCpuFirmwareNotCurrent NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "CPU Firmware Not Current; Cage Interface Card Failed ()" ::= { storeServAlerts 173 } componentStateChangeInterfaceCardFailed0x02d00faX1026 NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Interface Card Failed; Cage Interface Card Failed ()" ::= { storeServAlerts 174 } componentStateChangeInterfaceCardWarning NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Interface Card Warning; Cage Interface Card Failed ()" ::= { storeServAlerts 175 } componentStateChangeMissing0x03500faX1 NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Missing; Cage Magazine Failed ()" ::= { storeServAlerts 176 } componentStateChangeOffloopPowerSupplyFailure NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Offloop, Power Supply Failure; Cage Magazine Failed ()" ::= { storeServAlerts 177 } writeCacheAvailability NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "System write cache availability is degraded." ::= { storeServAlerts 178 } componentStateChangeVolumeUnsyncedRequiresAFullResyncSinceLd NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Volume Unsynced - requires a full resync since ldck is in progress; Remote Copy Volume () Degraded ()" ::= { storeServAlerts 179 } componentStateChangeResyncSnapshotBecameStaleFullSyncRequire NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Resync Snapshot Became Stale - full sync required; Remote Copy Volume () Degraded ()" ::= { storeServAlerts 180 } componentStateChangeVolumeGroupUnsyncedDidNotTakeSnapshotsWh NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Volume Group Unsynced - did not take snapshots while stopping group; Remote Copy Volume () Degraded ()" ::= { storeServAlerts 181 } componentStateChangeVolumeUnsyncedSecondaryVolumeWasNotMarke NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Volume Unsynced - secondary volume was not marked as in-sync; Remote Copy Volume () Degraded ()" ::= { storeServAlerts 182 } componentStateChangeVolumeUnsyncedVolumeWasUnavailableWhenGr NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Volume Unsynced - volume was unavailable when group was stopped; Remote Copy Volume () Degraded ()" ::= { storeServAlerts 183 } componentStateChangeVolumeUnsyncedNodeOrSysmgrFailure NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Volume Unsynced - node or sysmgr failure; Remote Copy Volume () Degraded ()" ::= { storeServAlerts 184 } componentStateChangeVolumeUnsyncedPromoteOfSnapshotFailed NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Volume Unsynced - promote of snapshot failed; Remote Copy Volume () Degraded ()" ::= { storeServAlerts 185 } componentStateChangeVolumeUnsyncedCouldNotTakeSnapshotDuring NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Volume Unsynced - could not take snapshot during sysmgr startup; Remote Copy Volume () Degraded ()" ::= { storeServAlerts 186 } componentStateChangeWriteToSecondaryVolumeFailed NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Write To Secondary Volume Failed; Remote Copy Volume () Failed ()" ::= { storeServAlerts 187 } componentStateChangeSyncFailed NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Sync Failed; Remote Copy Volume () Failed ()" ::= { storeServAlerts 188 } componentStateChangeSyncFailedCouldNotTakeLocalSnapshots NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Sync Failed - could not take local snapshots; Remote Copy Volume Group () Degraded ()" ::= { storeServAlerts 189 } componentStateChangeSyncFailedCouldNotTakeRemoteSnapshots NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Sync Failed - could not take remote snapshots; Remote Copy Volume Group () Degraded ()" ::= { storeServAlerts 190 } componentStateChangeSyncFailedCouldNotCommunicateWithTarget NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Sync Failed - could not communicate with target; Remote Copy Volume Group () Degraded ()" ::= { storeServAlerts 191 } componentStateChangeSyncFailedSynchronizationSnapshotHasBeen NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Sync Failed - synchronization snapshot has been deleted; Remote Copy Volume Group () Degraded ()" ::= { storeServAlerts 192 } componentStateChangeResyncFailedResynchronizationSnapshotHas NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Resync Failed - resynchronization snapshot has been deleted; Remote Copy Volume Group () Degraded ()" ::= { storeServAlerts 193 } componentStateChangeNotAllVolumesInGroupAreInSync NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Not All Volumes In Group Are In Sync; Remote Copy Volume Group () Degraded ()" ::= { storeServAlerts 194 } componentStateChangeResyncFailedVolumeIsCurrentlySyncing NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Resync Failed - volume is currently syncing; Remote Copy Volume Group () Degraded ()" ::= { storeServAlerts 195 } componentStateChangeAllLinksToTargetAreDown NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "All Links To Target Are Down; Remote Copy Target () Failed ()" ::= { storeServAlerts 196 } componentStateChangeNotAllConnectionsAreUp NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Not All Connections Are Up; Remote Copy Link () Degraded ()" ::= { storeServAlerts 197 } componentStateChangeDownDueToSendErrorOrMissingHeartbeat NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Down Due To Send Error Or Missing Heartbeat; Remote Copy Link () Failed ()" ::= { storeServAlerts 198 } componentStateChangeMultipleLinkDownErrorsWithin24Hours NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Multiple Link Down Errors Within 24 Hours; Remote Copy Link () Failed ()" ::= { storeServAlerts 199 } componentStateChangeLinkHasBeenDownForMoreThan4Hours NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Link Has Been Down For More Than 4 Hours; Remote Copy Link () Failed ()" ::= { storeServAlerts 200 } freeNodeDiskSpaceLow NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Node free disk space is below acceptable limits: root MB altroot MB common MB." ::= { storeServAlerts 201 } nodeDriveIsEncryptedButEncryptionIsNotEnabledOnTheSystem NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Node drive for node drive with WWN has encryption enabled, but encryption is not enabled on the system." ::= { storeServAlerts 202 } encryptionIsEnabledOnTheSystemButTheNodeDriveIsNotEncrypted NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Node drive for node drive with WWN is not encrypted, but encryption is enabled on the system." ::= { storeServAlerts 203 } unableToDoIOToTheNodeDrive NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Unable to do I/O to the node drive for node drive with WWN ." ::= { storeServAlerts 204 } syslogNodeDriveFailureMessageMonitoring NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "[[hw_node]] syslog received dual boot drive failure message. Problem exists on device: , on sata port: " ::= { storeServAlerts 205 } periodicProcMdstatMonitoringDetectedDegradedNodeDriveRaid NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "[[hw_node]] /proc/mdstat detected degraded node drive raid. Problem exists on device: , on sata port: " ::= { storeServAlerts 206 } processNameAppearsUnresponsive NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION " appears to be unresponsive." ::= { storeServAlerts 207 } processEventHandlingAppearsUnresponsive NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION " event handling appears to be unresponsive." ::= { storeServAlerts 208 } patrolDataCacheDimmUerr NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Node , Data Cache DIMM is failing. Uncorrectable Error." ::= { storeServAlerts 209 } controlCacheDimmTemperature NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Node Control Cache DIMM overheating ( C)." ::= { storeServAlerts 210 } componentStateChangeCageBatteryEndOfLife NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Cage Battery End of Life; Cage Cage Battery Degraded ()" ::= { storeServAlerts 211 } componentStateChangeCageBatteryFailed NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Cage Battery Failed; Cage Cage Battery Failed ()" ::= { storeServAlerts 212 } componentStateChangeCageBatteryNotPresent NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Cage Battery Not Present; Cage Cage Battery Failed ()" ::= { storeServAlerts 213 } componentStateChangeNodeControlCacheDimmFailure NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Node Control Cache DIMM Failure; Node , Contol_Cache_DIMM failed, ()" ::= { storeServAlerts 214 } componentStateChangeNodeDataCacheDimmFailure NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Node Data Cache DIMM Failure; Node , Data_Cache_DIMM failed, ()" ::= { storeServAlerts 215 } componentStateChangeNodeIdeDriveFailure NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Node IDE Drive Failure; Node , IDE_DRIVE failed, Instance: ()" ::= { storeServAlerts 216 } componentStateChangeNodeHbaFailure NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "Node HBA Failure; Node , HBA failed, Instance: ()" ::= { storeServAlerts 217 } sedIsFromTheWrongSystem NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "A self-encrypting drive with WWN belongs to another system: " ::= { storeServAlerts 218 } sedHasTheWrongKey NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "A self-encrypting drive with WWN has an unrecognized encryption key" ::= { storeServAlerts 219 } sedIsPresentButEncryptionIsNotEnabled NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "A self-encrypting drive with WWN is encrypted, but encryption is not enabled on the system." ::= { storeServAlerts 220 } lkmIsInAnUnknownState NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "The local Key Manager is in an invalid state" ::= { storeServAlerts 221 } nodesvrUnresponsiveDuringDarsvrStartup NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "The encryption management service is unavailable due to excessive failures getting encryption status from nodesvr during darsvr startup. If encryption is enabled on this system, drive replacement is prevented and the system will not be able to recover from power failure." ::= { storeServAlerts 222 } nodesvrUnresponsiveDuringFipsvrStartup NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "The encryption management service is unavailable due to excessive failures getting encryption status from nodesvr during fipsvr startup. If encryption is enabled on this system, drive replacement is prevented and the system will not be able to recover from power failure." ::= { storeServAlerts 223 } fipsvrUnableToStartInFipsMode NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "The encryption management service is unavailable because fipsvr failed to start up in FIPS mode. If encryption is enabled on this system, drive replacement is prevented and the system will not be able to recover from power failure." ::= { storeServAlerts 224 } failedToSuccessfullyCommunicateWithEkmAtStartup NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "The encryption management service is unavailable because communication failed to the External Key Manager during startup. If encryption is enabled on this system, drive replacement is prevented and the system will not be able to recover from power failure" ::= { storeServAlerts 225 } checkSnmpAlert NOTIFICATION-TYPE OBJECTS { component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "check snmp test alert" ::= { storeServAlerts 9999 } -- storeServAlerts compliance storeServAlertsGroup OBJECT-GROUP OBJECTS { index, component, details, nodeID, severity, timeOccurred, id, messageCode, state, serialNumber, tier, sparePartNumber, sysName } STATUS current DESCRIPTION "alertTable columns representing details about an event that may affect system operations and performance." ::= { storeServAlertsGroups 1 } storeServAlertsEvents NOTIFICATION-GROUP NOTIFICATIONS { activeVlunLimitExceeded, fcPortError, portDeviceCountExceeded, diskPortHasExceededIoErrorThreshold, componentStateChangeTargetModePortWentOffline, componentStateChangeTooManyInitiators, metadataInconsistencyInAVv, vlmapCountExceedsThreshold, flashcachePerformanceDegradation, metadataInconsistencyInADeduplicationGroup, vvUnrecoveredDifError, componentStateChangeMaintenanceCheckRequired, componentStateChangeLdsNotStarted, componentStateChangeCopyFailed, componentStateChangeSnapdataInvalid, componentStateChangeInternalConsistencyError, componentStateChangeNeedsToBeChecked, componentStateChangePreserved, componentStateChangeInvalid, componentStateChangeStale, ldskHasFailedSet, ldAvailabilityHasReduced, logLdRaidSetFailure, diskMonitorStopped, systemReporterPdPerformanceMajorAlert, systemOvertemp, diskOvertempButNotSpundown, diskOvertempAndSpundown, diskOvertempButNotSpundownNoDsk, diskOvertempAndSpundownNoDsk, componentStateChangeFailedHardware0x00600deX153, componentStateChangeMediaFailed0x00600deX156, componentStateChangeFailedHardware0x00600faX153, componentStateChangeMediaFailed0x00600faX156, componentStateChangeReplaceDrive0x00600faX70, doubleNodeFailure, nodeRecoveryPowerfailEvent, licenseKeyUsageLicenseExpired, systemRecoveryNotificationAboutBadVolume, batteryStates, systemRecoveryStalledDueToUnstartedVvs, unexpectedEncryptionStateOnNodeDrive, ideDiskErrorNodeShutdown, ideDiskErrorNodeNotShutdown, ideDiskErrorNodeNotShutdownLdsCannotBeServed, ideDiskErrorNodeReboot, authenticationFailure, nodeIsOffline, memoryUsageInformation, clusterThermalShutdown, nodeNeedsToShutdown, slabMemoryUsageOverLimit, systemReporterCmpPerformanceMajorAlert, systemReporterCpuPerformanceMajorAlert, systemReporterLinkPerformanceMajorAlert, cmpThreshold, systemReporterCachePerformanceMajorAlert, componentStateChangeTimeOfDayBatteryFailure, componentStateChangeCpuOverheating, componentStateChangeNodeOfflineDueToFailure0x01a00deX13, componentStateChangeCpuDead0x01a00deX19, componentStateChangeNodeFanModule0Failed0x01a00deX25, componentStateChangeNodeFanModule0PowerFault0x01a00deX28, componentStateChangeNodeFanModule0UnderLimit, componentStateChangeNodeThermalState, componentStateChangeNodeFanModule1Failed0x01a00deX33, componentStateChangeNodeFanModule1PowerFault0x01a00deX35, componentStateChangeNodeOfflineDueToFailure0x01a00faX13, componentStateChangeCpuDead0x01a00faX19, componentStateChangeNodeFanModule0Failed0x01a00faX25, componentStateChangeNodeFanModule0PowerFault0x01a00faX28, componentStateChangeUncorrectableMemoryError, componentStateChangeNodeThermalShutdown, componentStateChangeNodeFanModule1Failed0x01a00faX33, componentStateChangeNodeFanModule1PowerFault0x01a00faX35, componentStateChangeMultipleUncorrectableMemoryError, componentStateChangeDcFailed0x01b00faX1, componentStateChangeOverTemperature, componentStateChangeAcFailed, componentStateChangeFanFailed0x01b00faX3, componentStateChangeTemperatureUnderWarningThreshold0x01e00deX1, componentStateChangeOperatorsPanelFailed, componentStateChangeOperatorsPanelWarning, componentStateChangeUnsupportedCage, componentStateChangeTemperatureUnderWarningThreshold0x01e00faX1, componentStateChangeTemperatureUnderFailureThreshold, componentStateChangeTemperatureOverWarningThreshold, componentStateChangeInaccessible, componentStateChangeTemperatureOverFailureThreshold, componentStateChangePortBypassed, componentStateChangeNotready, componentStateChangeMissing0x01f00deX129, componentStateChangeInvalidConnections, componentStateChangeNotAvailableForAllocations, componentStateChangeOldFirmware, componentStateChangeDisabledAPort, componentStateChangeMissingAPort, componentStateChangeErrorsOnAPort, componentStateChangeProlongedMissingAPort, componentStateChangeDisabledBPort, componentStateChangeMissingBPort, componentStateChangeErrorsOnBPort, componentStateChangeProlongedMissingBPort, componentStateChangeOverTemperatureWarning, componentStateChangeOverTemperatureAlert, componentStateChangeInvalidMedia, componentStateChangeFailedHardware0x01f00deX153, componentStateChangeSmartThresholdExceeded, componentStateChangeMultipleChunkletsMediaBad, componentStateChangeMediaFailed0x01f00deX156, componentStateChangeIncreasedErrorCount, componentStateChangeDifThresholdExceeded, componentStateChangeProlongedNotReady, componentStateChangeNoValidPorts, componentStateChangeInquiryFailed, componentStateChangeUnitReadyFailed, componentStateChangeReadCapacityFailed, componentStateChangeWriteLabelFailed, componentStateChangeModePageUpdateFailed, componentStateChangeReadLabelFailed, componentStateChangeMediumFormatCorrupted, componentStateChangeLowWearLevelRemaining, componentStateChangeMiscompare, componentStateChangeInvalidCage, componentStateChangeSlowDrive, componentStateChangeServicing, componentStateChangeDriveErrorBitSet, componentStateChangeFailedHardware0x01f00faX153, componentStateChangeMediaFailed0x01f00faX156, componentStateChangeReplaceDrive0x01f00faX70, internalErrorInAuthenticationLibrary, assertBatteryFail, componentStateChangeExpired, componentStateChangeChargingFailed, componentStateChangeInternalError, componentStateChangeLoadSharingFailed, componentStateChangeFanFailed0x02200deX6, componentStateChangeDcFailed0x02200deX7, componentStateChangeChargerFailed, componentStateChangeFailed, portShutdownOnFatalError, hostPortIsDown, remoteCopyLinkStatus, replicationResourceUsageExceededGroupLogging, replicationResourceUsageExceededGroupStopped, replicationResourcesRestoredGroupTransitionFromLoggingFailur, noAdminNetworkInterfaceDiscovered, tpVvAllocationSizeLimit, snapshotSpaceAllocationSizeLimit, cpgGrowthLimit, tpVvAllocationFailure, snapshotSpaceAllocationFailure, fcRawSpaceAllocation75Alert, fcRawSpaceAllocation85Alert, fcRawSpaceAllocation95Alert, nlRawSpaceAllocation75Alert, nlRawSpaceAllocation85Alert, nlRawSpaceAllocation95Alert, ssdRawSpaceAllocation75Alert, ssdRawSpaceAllocation85Alert, ssdRawSpaceAllocation95Alert, preservedDataLdsAreFull, componentStateChangePowerSupplyFanWarning, componentStateChangePowerSupplyOff, componentStateChangePowerSupplyFailed0x02b00faX1, componentStateChangePowerSupplyFailed0x02b00faX1026, componentStateChangePowerSupplyWarning, componentStateChangePowerSupplyFanNotPresent, componentStateChangePowerSupplyFanNotAvailable, componentStateChangePowerSupplyNotAvailable, componentStateChangePowerSupplyAcFailed, componentStateChangeInterfaceCardFailed0x02d00deX1026, componentStateChangeCpuFirmwareNotCurrent, componentStateChangeInterfaceCardFailed0x02d00faX1026, componentStateChangeInterfaceCardWarning, componentStateChangeMissing0x03500faX1, componentStateChangeOffloopPowerSupplyFailure, writeCacheAvailability, componentStateChangeVolumeUnsyncedRequiresAFullResyncSinceLd, componentStateChangeResyncSnapshotBecameStaleFullSyncRequire, componentStateChangeVolumeGroupUnsyncedDidNotTakeSnapshotsWh, componentStateChangeVolumeUnsyncedSecondaryVolumeWasNotMarke, componentStateChangeVolumeUnsyncedVolumeWasUnavailableWhenGr, componentStateChangeVolumeUnsyncedNodeOrSysmgrFailure, componentStateChangeVolumeUnsyncedPromoteOfSnapshotFailed, componentStateChangeVolumeUnsyncedCouldNotTakeSnapshotDuring, componentStateChangeWriteToSecondaryVolumeFailed, componentStateChangeSyncFailed, componentStateChangeSyncFailedCouldNotTakeLocalSnapshots, componentStateChangeSyncFailedCouldNotTakeRemoteSnapshots, componentStateChangeSyncFailedCouldNotCommunicateWithTarget, componentStateChangeSyncFailedSynchronizationSnapshotHasBeen, componentStateChangeResyncFailedResynchronizationSnapshotHas, componentStateChangeNotAllVolumesInGroupAreInSync, componentStateChangeResyncFailedVolumeIsCurrentlySyncing, componentStateChangeAllLinksToTargetAreDown, componentStateChangeNotAllConnectionsAreUp, componentStateChangeDownDueToSendErrorOrMissingHeartbeat, componentStateChangeMultipleLinkDownErrorsWithin24Hours, componentStateChangeLinkHasBeenDownForMoreThan4Hours, freeNodeDiskSpaceLow, nodeDriveIsEncryptedButEncryptionIsNotEnabledOnTheSystem, encryptionIsEnabledOnTheSystemButTheNodeDriveIsNotEncrypted, unableToDoIOToTheNodeDrive, syslogNodeDriveFailureMessageMonitoring, periodicProcMdstatMonitoringDetectedDegradedNodeDriveRaid, processNameAppearsUnresponsive, processEventHandlingAppearsUnresponsive, patrolDataCacheDimmUerr, controlCacheDimmTemperature, componentStateChangeCageBatteryEndOfLife, componentStateChangeCageBatteryFailed, componentStateChangeCageBatteryNotPresent, componentStateChangeNodeControlCacheDimmFailure, componentStateChangeNodeDataCacheDimmFailure, componentStateChangeNodeIdeDriveFailure, componentStateChangeNodeHbaFailure, sedIsFromTheWrongSystem, sedHasTheWrongKey, sedIsPresentButEncryptionIsNotEnabled, lkmIsInAnUnknownState, nodesvrUnresponsiveDuringDarsvrStartup, nodesvrUnresponsiveDuringFipsvrStartup, fipsvrUnableToStartInFipsMode, failedToSuccessfullyCommunicateWithEkmAtStartup, checkSnmpAlert } STATUS current DESCRIPTION "A collection of events for storeServAlerts" ::= { storeServAlertsGroups 2 } storeServAlertsCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "A collection of objects providing basic instrumentation for a HPE 3PAR server." MODULE MANDATORY-GROUPS { storeServAlertsGroup, storeServAlertsEvents } ::= { storeServAlertsCompliances 1 } -- snmp v2c trap extension compliances -- snmpv2TrapExtensionGroups OBJECT IDENTIFIER ::= { inservGroups 3 } snmpv2TrapExtensionCompliances OBJECT IDENTIFIER ::= { inservCompls 3 } snmpv2TrapExtensionObjectsGroup OBJECT-GROUP OBJECTS { managerIp } STATUS current DESCRIPTION "The extra object bindings extending selected standard SNMPv2 traps: managerIP extends the authenticationFailure trap." ::= { snmpv2TrapExtensionGroups 1 } snmpv2TrapExtensionEventsGroup NOTIFICATION-GROUP NOTIFICATIONS { authenticationFailure } STATUS current DESCRIPTION "SNMPv2 traps extended with extra object bindings by HPE 3PAR." ::= { snmpv2TrapExtensionGroups 2 } snmpv2TrapExtensionCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "Compliance for SNMPv2 standard traps that are extended by HPE 3PAR." MODULE MANDATORY-GROUPS { snmpv2TrapExtensionObjectsGroup, snmpv2TrapExtensionEventsGroup } ::= { snmpv2TrapExtensionCompliances 1 } END