HPE-SENSORENTMIB DEFINITIONS ::= BEGIN IMPORTS rlEnv FROM HPE-HWENVIROMENT MODULE-IDENTITY, OBJECT-TYPE, Integer32, Unsigned32, mib-2 FROM SNMPv2-SMI entPhySensorEntry FROM ENTITY-SENSOR-MIB MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF TEXTUAL-CONVENTION, TimeStamp FROM SNMPv2-TC entPhysicalIndex, entityPhysicalGroup FROM ENTITY-MIB SnmpAdminString FROM SNMP-FRAMEWORK-MIB EntitySensorValue FROM ENTITY-SENSOR-MIB; rlSensor MODULE-IDENTITY LAST-UPDATED "200309210000Z" ORGANIZATION "HPE" CONTACT-INFO "HPE" DESCRIPTION "The private MIB module definition for sensors in HPE devices." REVISION "200309210000Z" DESCRIPTION "Add DDR sensor." REVISION "201906300000Z" DESCRIPTION "ADDED this MODULE-IDENTITY clause." ::= { rlEnv 4 } RlEntitySensorLocation ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "An object using this data type represents the location of a physical sensor. The value 'pcb(1)' indicates that sensor is external or located in thermal controller (on PCB). The value 'pp(2)' indicates that sensor is located in packet processor chip. The value 'poe(3)' indicates that sensor is located in PoE chip. The value 'phy(4)' indicates that sensor is located in PHY chip. The value 'cpu(5)' indicates that sensor is located in CPU chip. The value 'ddr(6)' indicates that sensor is located in DDR chip. The value 'notassembled(7)' indicates that sensor is not assembled." SYNTAX INTEGER { pcb(1), pp(2), poe(3), phy(4), cpu(5), ddr(6), notassembled(7) } rlEntPhySensorTable OBJECT-TYPE SYNTAX SEQUENCE OF RlEntPhySensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The addition to the table of sensors maintained by the environmental monitor." ::= { rlEnv 3 } rlEntPhySensorEntry OBJECT-TYPE SYNTAX RlEntPhySensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An additon to the entry in the sensor table, representing the maximum/minimum values for the sensor associated." AUGMENTS {entPhySensorEntry} ::= { rlEntPhySensorTable 1 } RlEntPhySensorEntry ::= SEQUENCE { rlEnvPhySensorMinValue EntitySensorValue, rlEnvPhySensorMaxValue EntitySensorValue, rlEnvPhySensorTestValue EntitySensorValue, rlEnvPhySensorLocation RlEntitySensorLocation } rlEnvPhySensorMinValue OBJECT-TYPE SYNTAX EntitySensorValue MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum value for the Sensor being instrumented." ::= { rlEntPhySensorEntry 1 } rlEnvPhySensorMaxValue OBJECT-TYPE SYNTAX EntitySensorValue MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum value for the Sensor being instrumented." ::= { rlEntPhySensorEntry 2 } rlEnvPhySensorTestValue OBJECT-TYPE SYNTAX EntitySensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "Test/reference value for the Sensor being instrumented." ::= { rlEntPhySensorEntry 3 } rlEnvPhySensorLocation OBJECT-TYPE SYNTAX RlEntitySensorLocation MAX-ACCESS read-only STATUS current DESCRIPTION "Location value for the Sensor being instrumented." ::= { rlEntPhySensorEntry 4 } END