-- OPTIX-RTN-IF-PROTECT-MGR-MIB -- MIB generated by ExcelToMIB tool 1.0 -- -- ================================================================= -- Copyright (C) 2012 by HUAWEI TECHNOLOGIES. All rights reserved -- Description: -- Reference: -- Version: V1.00 -- History: -- ,, -- ================================================================= -- OPTIX-RTN-IF-PROTECT-MGR-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-GROUP,MODULE-COMPLIANCE FROM SNMPv2-CONF Integer32,Unsigned32,OBJECT-TYPE,MODULE-IDENTITY,NOTIFICATION-TYPE FROM SNMPv2-SMI TEXTUAL-CONVENTION,RowStatus FROM SNMPv2-TC optixProvisionRtn FROM OPTIX-OID-MIB OPTIXRtnEnableStateType,optixRtnIndex1,optixRtnIndex2,optixRtnIndex3,optixRtnIndex4,optixRtngroupIndex,optixRtnboardIndex,optixRtnsubboardIndex,optixRtnportIndex FROM OPTIX-RTN-GENNERAL-MIB OPTIXRtnModulateModeType,OPTIXRtnBandWidthType,optixRtnBoardID,optixRtnSubCardID,optixRtnPortID FROM OPTIX-RTN-IFBOARD-ATTRIB-MIB OPTIXRtnOduWorkStateType FROM OPTIX-RTN-ODU-MGR-MIB ; optixRtnIFProtectMgr MODULE-IDENTITY LAST-UPDATED "201204160935Z" ORGANIZATION "Huawei Technologies co.,Ltd." CONTACT-INFO "R&D Building Huawei Technologies Co., Ltd. Bantian, Longgang District Shenzhen, P. R. China http://www.huawei.com Zip:518129 E-mail:support@huawei.com" DESCRIPTION "This module is used to configure and query information about IF 1+1, IF N+1, XPIC, and PLA protection groups of RTN equipment, including the board position mapping, switching parameters, and the protection group status." REVISION "201204160935Z" DESCRIPTION "The initial revision of this MIB module1." ::={ optixProvisionRtn 5 } OPTIXRtn1j1PGSwCmdType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Indicates the switching type of an IF 1+1 protection group. The value can be Manual, Force, Lockout, Clear, or unknown." SYNTAX INTEGER { if1j1Manual(0), if1j1Force(1), if1j1Lockout(2), if1j1Clear(3), unknown(-1) } OPTIXRtn1j1PGSwDirType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Indicates the switching direction of an IF 1+1 protection group. The value can be WorkToProtect, ProtectToWork, or unknown." SYNTAX INTEGER { if1j1WorkToProtect(0), if1j1ProtectToWork(1), unknown(-1) } OPTIXRtnNj1PGSwCmdType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Indicates the switching type of an IF N+1 protection group. The value can be Lock, Unlock, Force, Forceclr, Man, Manclr, Exer, Exerclr, Clearall, Wtrclr, or unknown." SYNTAX Unsigned32 { ifNj1Lock(15), ifNj1Unlock(31), ifNj1Force(14), ifNj1Forceclr(30), ifNj1Man(8), ifNj1Manclr(24), ifNj1Exer(4), ifNj1Exerclr(20), ifNj1Clearall(16), ifNj1Wtrclr(22), null(255) } OPTIXRtnCascading1j1PGProtectType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Indicates the service protection type of a cascading IF 1+1 protection group. Values: 0: noprot 1: lagprot 2: splitprot 255: invalid" SYNTAX Unsigned32 { noprot(0), lagprot(1), splitprot(2), invalid(255) } OPTIXRtnCascadingPhyLagPGProtectTypeExt ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Indicates the type of a cascading IF PLA protection group. Values:0: no protection 1: LAG protection 2: optical splitter protection 3:active active protection" SYNTAX INTEGER { noProtect(0), lagProtect(1), splitProtect(2), activeActive(3) } OPTIXRtnPgType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Indicates the protection group type." SYNTAX INTEGER { if1j1(1), vs1j1(2) } AlarmINHPG1J1EventType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Indicates the alarm ID for inhibition." SYNTAX INTEGER { almMwBerEXC(12870), almMwBerSD(12871), almMwRdi(12587), almRadioRslLow(638), almMacExtExc(13444), almMacFcsExc(12794), all(0) } OPTIXRtnExtNj1Mode ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Indicates the mode of the N+1 protection group." SYNTAX INTEGER { normal(0), enhanced(1) } OPTIXRtnNJ1ProtocolState ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Indicates the status of the N+1 protection group." SYNTAX INTEGER { stop(0), start(1) } OPTIXRtn1j1DevWorkBoardProperty ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Indicates the Property of 1j1 protect group" SYNTAX INTEGER { work(0), port(1), unknown(-1) } OPTIXRtnCascading1j1PGRoleType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Indicates the role of a cascading IF 1+1 protection group. Values: 0: working 1: protection" SYNTAX INTEGER { work(0), protect(1) } OPTIXRtnPhyLagPGStatus ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Indicates the status of a PLA protection group. Values: 0: normal 1: abnormal -1: unknown" SYNTAX INTEGER { normal(0), abnormal(1), inhibited(2), uniNormal(3), unknown(-1) } OPTIXRtn1j1SwtichRequestType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Indicates the switching request of an IF 1+1 protection group. Value range: 0: normal 1: automatic 2: manual 3: forced 4: lockout 5: wait to restore 6: RDI" SYNTAX INTEGER { normal(0), automatic(1), manual(2), forced(3), lockout(4), waitRestore(5), rdi(6) } OPTIXRtn1j1LinkStateType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Indicates the IF 1+1 link status. Values: 0: normal 1: signal failure 2: signal deterioration -1: invalid" SYNTAX INTEGER { normal(0), signalFailure(1), signalDeterioration(2), invalid(-1) } OPTIXRtnPhyLagPGStateWorkStatus ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Indicates the channel status of a PLA protection group. Values: 0: slave 1: master -1: unknown" SYNTAX INTEGER { slave(0), master(1), unknown(-1) } OPTIXRtnNj1PGSwitchRequestType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Indicates the switching request of an IF N+1 protection group. Values: 240: lockout 224: force 208: SF 176: SD 128: manual 96: wait to restore 64: exercise switching 32: reverse request 0: No request" SYNTAX INTEGER { lockout(240), force(224), sf(208), sd(176), manual(128), waitRestore(96), exerciseSwitching(64), reverseRequest(32), noRequest(0), forceLow(192), dnr(16) } OPTIXRtnNj1PGFarNearType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Indicates the switching far and near ends of an IF N+1 protection group. Values: 0: none 1: near end 2: far end" SYNTAX INTEGER { nornindi(0), near(1), remote(2) } OPTIXRtnPhyLagPGType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Indicates the type of an IF PLA protection group. Values: 0: pla, 1: epla, 2: nbpla, 3: nbepla,4: epla plus,5: sepla" SYNTAX INTEGER { pla(0), epla(1), nbpla(2), nbepla(3), eplaplus(4), sepla(5), seplaslave(6), seplasecondgeneration(7), seplaslavesecondgeneration(8) } OPTIXRtnCascadingPLAPGRoleType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Indicates the role of a cascading IF PLA protection group. Values: 0: slave NE 1: main NE -1:unknown" SYNTAX INTEGER { slave(0), master(1), unknown(-1) } OPTIXRtn1j1PGWorkModeType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Indicates the working mode of an IF 1+1 protection group. Values: 0: SD 1: FD 2: HSB" SYNTAX INTEGER { modeSD(0), modeFD(1), modeHSB(2) } OPTIXRtn1j1PGAlmReportModeType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Indicates the service alarm report mode. Values: 1: only board alarms 2: only protection group alarms 3: Protection group and board alarms" SYNTAX INTEGER { onlyBoardAlm(1), onlyProtectionGroupAlm(2), bothPgAndBoard(3) } OPTIXRtnRvtModeType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Indicates the revertive mode of an IF protection group. Values: 0: Norvt (non-revertive) 1: Rvt (revertive)" SYNTAX INTEGER { noRvt(0), rvt(1) } OPTIXRtnCascadingPhyLagPGProtectType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Indicates the type a cascading IF PLA protection group. Values:0: unprotected 1: protected -1: invalid" SYNTAX INTEGER { noProtect(0), protect(1), invalid(-1) } OPTIXRtn1j1PGBDStateType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Indicates the working status of an IF 1+1 board. Values: 0: normal 1: switching 2: RDI switching -1: unknown" SYNTAX INTEGER { normal(0), fail(1), rdiSwitching(2), unknown(-1) } OPTIXRtnNj1SwitchStateType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Indicates the switching status of an IF N+1 protection group. Values: 0: not started 1: idling 4: switching -1: protocol is starting" SYNTAX INTEGER { stop(0), idling(1), switching(4), starting(-1) } OPTIXRtnNj1PGSwitchReasonType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Cause type for IF 1+1 protection switching" SYNTAX INTEGER { local(1), extsw(2), kByte(3), timerOut(4) } OPTIXRtnStrategyType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Indicates the type of energysave" SYNTAX INTEGER { green(0) } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10 optixRtnIFProtect OBJECT IDENTIFIER ::= { optixRtnIFProtectMgr 10 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.10 optixRtn1j1PGParameterTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtn1j1PGParameterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Describes configuration parameters for the working board and protection board in an IF 1+1 protection group." ::= { optixRtnIFProtect 10 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.10.1 optixRtn1j1PGParameterEntry OBJECT-TYPE SYNTAX OptixRtn1j1PGParameterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the parameter entry for an IF 1+1 protection group." INDEX{ optixRtn1j1PGID } ::= { optixRtn1j1PGParameterTable 1 } OptixRtn1j1PGParameterEntry ::= SEQUENCE { optixRtn1j1PGID Unsigned32, optixRtn1j1PGWorkBoardID Unsigned32, optixRtn1j1PGWorkSubCardID Unsigned32, optixRtn1j1PGWorkPortID Unsigned32, optixRtn1j1PGProtectBoardID Unsigned32, optixRtn1j1PGProtectSubCardID Unsigned32, optixRtn1j1PGProtectPortID Unsigned32, optixRtn1j1PGWorkMode OPTIXRtn1j1PGWorkModeType, optixRtn1j1PGRevertiveMode OPTIXRtnRvtModeType, optixRtn1j1PGWTRTime Unsigned32, optixRtn1j1PGRDISwEnableState OPTIXRtnEnableStateType, optixRtn1j1PGAlmReportMode OPTIXRtn1j1PGAlmReportModeType, optixRtn1j1PGAntiJitterTime Unsigned32, optixRtn1j1PGSwCmd OPTIXRtn1j1PGSwCmdType, optixRtn1j1PGSwDir OPTIXRtn1j1PGSwDirType, optixRtn1j1PGCfgRowStatus RowStatus } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.10.1.1 optixRtn1j1PGID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the IF 1+1 protection group ID." ::= { optixRtn1j1PGParameterEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.10.1.2 optixRtn1j1PGWorkBoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the working board ID of an IF 1+1 protection group." ::= { optixRtn1j1PGParameterEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.10.1.3 optixRtn1j1PGWorkSubCardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the working subboard ID of an IF 1+1 protection group." DEFVAL{ 255 } ::= { optixRtn1j1PGParameterEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.10.1.4 optixRtn1j1PGWorkPortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the working port ID of an IF 1+1 protection group." DEFVAL{ 1 } ::= { optixRtn1j1PGParameterEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.10.1.5 optixRtn1j1PGProtectBoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the protection board ID of an IF 1+1 protection group." ::= { optixRtn1j1PGParameterEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.10.1.6 optixRtn1j1PGProtectSubCardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the protection subboard ID of an IF 1+1 protection group." DEFVAL{ 255 } ::= { optixRtn1j1PGParameterEntry 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.10.1.7 optixRtn1j1PGProtectPortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the protection port ID of an IF 1+1 protection group." DEFVAL{ 1 } ::= { optixRtn1j1PGParameterEntry 7 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.10.1.8 optixRtn1j1PGWorkMode OBJECT-TYPE SYNTAX OPTIXRtn1j1PGWorkModeType MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the working mode of an IF 1+1 protection group. Values: 0: SD 1: FD 2: HSB" DEFVAL{ 2 } ::= { optixRtn1j1PGParameterEntry 8 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.10.1.9 optixRtn1j1PGRevertiveMode OBJECT-TYPE SYNTAX OPTIXRtnRvtModeType MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the revertive mode of an IF 1+1 protection group. Values: 0: Norvt (non-revertive) 1: Rvt (revertive)" DEFVAL{ 1 } ::= { optixRtn1j1PGParameterEntry 9 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.10.1.10 optixRtn1j1PGWTRTime OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the WTR time of an IF 1+1 protection group. Value range: 300s to 720s" DEFVAL{ 600 } ::= { optixRtn1j1PGParameterEntry 10 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.10.1.11 optixRtn1j1PGRDISwEnableState OBJECT-TYPE SYNTAX OPTIXRtnEnableStateType MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the reverse switching status of an IF 1+1 protection group(this node is used only on RTN900 devices). Values: 0: disabled 1: enabled" DEFVAL{ 1 } ::= { optixRtn1j1PGParameterEntry 11 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.10.1.12 optixRtn1j1PGAlmReportMode OBJECT-TYPE SYNTAX OPTIXRtn1j1PGAlmReportModeType MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the service alarm report mode of an IF 1+1 protection group(this node is used only on RTN900 devices). Values: 1: only board alarms 2: only protection group alarms 3: PG group and board alarms" DEFVAL{ 1 } ::= { optixRtn1j1PGParameterEntry 12 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.10.1.13 optixRtn1j1PGAntiJitterTime OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the anti-jitter time of the switching alarm for an IF 1+1 protection group(this node is used only on RTN900 devices). Value range: 0s to 600s" DEFVAL{ 300 } ::= { optixRtn1j1PGParameterEntry 13 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.10.1.14 optixRtn1j1PGSwCmd OBJECT-TYPE SYNTAX OPTIXRtn1j1PGSwCmdType MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the switching mode of an IF 1+1 protection group(this node is used only on RTN900 devices)." ::= { optixRtn1j1PGParameterEntry 14 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.10.1.15 optixRtn1j1PGSwDir OBJECT-TYPE SYNTAX OPTIXRtn1j1PGSwDirType MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the switching direction of an IF 1+1 protection group(this node is used only on RTN900 devices)." ::= { optixRtn1j1PGParameterEntry 15 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.10.1.50 optixRtn1j1PGCfgRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the row status of an IF 1+1 protection group." DEFVAL{ active } ::= { optixRtn1j1PGParameterEntry 50 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.20 optixRtn1j1PGStateTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtn1j1PGStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Describes the current status of an IF 1+1 protection group, including the current working board and switching status of the protection group." ::= { optixRtnIFProtect 20 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.20.1 optixRtn1j1PGStateEntry OBJECT-TYPE SYNTAX OptixRtn1j1PGStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the parameter entry for the current status of an IF 1+1 protection group." INDEX{ optixRtn1j1PGID } ::= { optixRtn1j1PGStateTable 1 } OptixRtn1j1PGStateEntry ::= SEQUENCE { optixRtn1j1PGStateDevWorkBoardID Unsigned32, optixRtn1j1PGStateDevWorkSubCardID Unsigned32, optixRtn1j1PGStateWorkPortID Unsigned32, optixRtn1j1PGDevWorkBoardState OPTIXRtn1j1PGBDStateType, optixRtn1j1PGDevProtectBoardState OPTIXRtn1j1PGBDStateType, optixRtn1j1PGDevSwtichRequest OPTIXRtn1j1SwtichRequestType, optixRtn1j1PGLinkWorkBoardID Unsigned32, optixRtn1j1PGLinkDevWorkSubCardID Unsigned32, optixRtn1j1PGLinkWorkPortID Unsigned32, optixRtn1j1PGWorkBoardLinkState OPTIXRtn1j1LinkStateType, optixRtn1j1PGProtBoardLinkState OPTIXRtn1j1LinkStateType, optixRtn1j1PGProtLinkSwitchRequest OPTIXRtn1j1SwtichRequestType } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.20.1.1 optixRtn1j1PGStateDevWorkBoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current working board ID of an IF 1+1 protection group on the equipment side." ::= { optixRtn1j1PGStateEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.20.1.2 optixRtn1j1PGStateDevWorkSubCardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current working subboard ID of an IF 1+1 protection group on the equipment side." DEFVAL{ 255 } ::= { optixRtn1j1PGStateEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.20.1.3 optixRtn1j1PGStateWorkPortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current working port ID of an IF 1+1 protection group on the equipment side." ::= { optixRtn1j1PGStateEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.20.1.4 optixRtn1j1PGDevWorkBoardState OBJECT-TYPE SYNTAX OPTIXRtn1j1PGBDStateType MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the working status of the main board on the equipment side. Values: 0: normal 1: switching 2: RDI switching -1: unknown" ::= { optixRtn1j1PGStateEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.20.1.5 optixRtn1j1PGDevProtectBoardState OBJECT-TYPE SYNTAX OPTIXRtn1j1PGBDStateType MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the working status of the standby board on the equipment side. Values: 0: normal 1: switching 2: RDI switching -1: unknown" ::= { optixRtn1j1PGStateEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.20.1.6 optixRtn1j1PGDevSwtichRequest OBJECT-TYPE SYNTAX OPTIXRtn1j1SwtichRequestType MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the switching request on the equipment side. Value range: 0: normal 1: automatic 2: manual 3: forced 4: lockout 5: wait to restore 6: RDI" ::= { optixRtn1j1PGStateEntry 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.20.1.7 optixRtn1j1PGLinkWorkBoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current working board ID on the link side." ::= { optixRtn1j1PGStateEntry 7 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.20.1.8 optixRtn1j1PGLinkDevWorkSubCardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current working subboard ID on the link side." DEFVAL{ 255 } ::= { optixRtn1j1PGStateEntry 8 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.20.1.9 optixRtn1j1PGLinkWorkPortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current working board port ID on the link side." ::= { optixRtn1j1PGStateEntry 9 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.20.1.10 optixRtn1j1PGWorkBoardLinkState OBJECT-TYPE SYNTAX OPTIXRtn1j1LinkStateType MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the signal status of the main board link. Values: 0: normal 1: signal failure 2: signal deterioration -1: invalid" ::= { optixRtn1j1PGStateEntry 10 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.20.1.11 optixRtn1j1PGProtBoardLinkState OBJECT-TYPE SYNTAX OPTIXRtn1j1LinkStateType MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the signal status of the standby board link. Values: 0: normal 1: signal failure 2: signal deterioration -1: invalid" ::= { optixRtn1j1PGStateEntry 11 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.20.1.12 optixRtn1j1PGProtLinkSwitchRequest OBJECT-TYPE SYNTAX OPTIXRtn1j1SwtichRequestType MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the switching request on the link side. Values: 0: normal 1: automatic 3: forced" ::= { optixRtn1j1PGStateEntry 12 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.30 optixRtnNj1PGParameterTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnNj1PGParameterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Describes configuration parameters for the working board and protection board in an IF N+1 protection group." ::= { optixRtnIFProtect 30 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.30.1 optixRtnNj1PGParameterEntry OBJECT-TYPE SYNTAX OptixRtnNj1PGParameterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the parameter entry for an IF N+1 protection group." INDEX{ optixRtnNj1PGID } ::= { optixRtnNj1PGParameterTable 1 } OptixRtnNj1PGParameterEntry ::= SEQUENCE { optixRtnNj1PGID Unsigned32, optixRtnNj1PGWTRTime Unsigned32, optixRtnNj1PGSDFlag OPTIXRtnEnableStateType, optixRtnNj1PGWorkChunnelNum Unsigned32, optixRtnNj1PGProtectBoardID Unsigned32, optixRtnNj1PGProtectSubCardID Unsigned32, optixRtnNj1PGProtectPortID Unsigned32, optixRtnNj1PGWorkBoardID1 Unsigned32, optixRtnNj1PGWorkSubCardID1 Unsigned32, optixRtnNj1PGWorkPortID1 Unsigned32, optixRtnNj1PGWorkBoardID2 Unsigned32, optixRtnNj1PGWorkSubCardID2 Unsigned32, optixRtnNj1PGWorkPortID2 Unsigned32, optixRtnNj1PGWorkBoardID3 Unsigned32, optixRtnNj1PGWorkSubCardID3 Unsigned32, optixRtnNj1PGWorkPortID3 Unsigned32, optixRtnNj1PGWorkBoardID4 Unsigned32, optixRtnNj1PGWorkSubCardID4 Unsigned32, optixRtnNj1PGWorkPortID4 Unsigned32, optixRtnNj1PGWorkBoardID5 Unsigned32, optixRtnNj1PGWorkSubCardID5 Unsigned32, optixRtnNj1PGWorkPortID5 Unsigned32, optixRtnNj1PGWorkBoardID6 Unsigned32, optixRtnNj1PGWorkSubCardID6 Unsigned32, optixRtnNj1PGWorkPortID6 Unsigned32, optixRtnNj1PGWorkBoardID7 Unsigned32, optixRtnNj1PGWorkSubCardID7 Unsigned32, optixRtnNj1PGWorkPortID7 Unsigned32, optixRtnNj1PGStartProtocol Unsigned32, optixRtnNj1PGStopProtocol Unsigned32, optixRtnNj1PGSwChannel Unsigned32, optixRtnNj1PGSwCmd OPTIXRtnNj1PGSwCmdType, optixRtnNj1PGWorkChunnelsInfo OCTET STRING, optixRtnNj1PGCfgRowStatus RowStatus } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.30.1.1 optixRtnNj1PGID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the IF N+1 protection group ID." ::= { optixRtnNj1PGParameterEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.30.1.2 optixRtnNj1PGWTRTime OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the WTR time of an IF N+1 protection group. Value range: 300s to 720s" DEFVAL{ 600 } ::= { optixRtnNj1PGParameterEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.30.1.3 optixRtnNj1PGSDFlag OBJECT-TYPE SYNTAX OPTIXRtnEnableStateType MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the SD status of an IF N+1 protection group. Values: 0: disabled 1: enabled" DEFVAL{ 1 } ::= { optixRtnNj1PGParameterEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.30.1.4 optixRtnNj1PGWorkChunnelNum OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the number of working channels in an IF N+1 protection group." ::= { optixRtnNj1PGParameterEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.30.1.5 optixRtnNj1PGProtectBoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the ID of the board on a protection channel in an IF N+1 protection group." ::= { optixRtnNj1PGParameterEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.30.1.6 optixRtnNj1PGProtectSubCardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the ID of the subboard on a protection channel in an IF N+1 protection group." ::= { optixRtnNj1PGParameterEntry 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.30.1.7 optixRtnNj1PGProtectPortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the ID of the port on a protection channel in an IF N+1 protection group." ::= { optixRtnNj1PGParameterEntry 7 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.30.1.8 optixRtnNj1PGWorkBoardID1 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the ID of the board on the first-priority working channel in an IF N+1 protection group." ::= { optixRtnNj1PGParameterEntry 8 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.30.1.9 optixRtnNj1PGWorkSubCardID1 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the ID of the subboard on the first-priority working channel in an IF N+1 protection group." ::= { optixRtnNj1PGParameterEntry 9 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.30.1.10 optixRtnNj1PGWorkPortID1 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the ID of the port on the first-priority working channel in an IF N+1 protection group." ::= { optixRtnNj1PGParameterEntry 10 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.30.1.11 optixRtnNj1PGWorkBoardID2 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the ID of the board on the second-priority working channel in an IF N+1 protection group." ::= { optixRtnNj1PGParameterEntry 11 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.30.1.12 optixRtnNj1PGWorkSubCardID2 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the ID of the subboard on the second-priority working channel in an IF N+1 protection group." DEFVAL{ 255 } ::= { optixRtnNj1PGParameterEntry 12 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.30.1.13 optixRtnNj1PGWorkPortID2 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the ID of the port on the second-priority working channel in an IF N+1 protection group." DEFVAL{ 255 } ::= { optixRtnNj1PGParameterEntry 13 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.30.1.14 optixRtnNj1PGWorkBoardID3 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the ID of the board on the third-priority working channel in an IF N+1 protection group." DEFVAL{ 255 } ::= { optixRtnNj1PGParameterEntry 14 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.30.1.15 optixRtnNj1PGWorkSubCardID3 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the ID of the subboard on the third-priority working channel in an IF N+1 protection group." DEFVAL{ 255 } ::= { optixRtnNj1PGParameterEntry 15 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.30.1.16 optixRtnNj1PGWorkPortID3 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the ID of the port on the third-priority working channel in an IF N+1 protection group." DEFVAL{ 255 } ::= { optixRtnNj1PGParameterEntry 16 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.30.1.17 optixRtnNj1PGWorkBoardID4 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the ID of the board on the fourth-priority working channel in an IF N+1 protection group." DEFVAL{ 255 } ::= { optixRtnNj1PGParameterEntry 17 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.30.1.18 optixRtnNj1PGWorkSubCardID4 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the ID of the subboard on the fourth-priority working channel in an IF N+1 protection group." DEFVAL{ 255 } ::= { optixRtnNj1PGParameterEntry 18 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.30.1.19 optixRtnNj1PGWorkPortID4 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the ID of the port on the fourth-priority working channel in an IF N+1 protection group." DEFVAL{ 255 } ::= { optixRtnNj1PGParameterEntry 19 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.30.1.20 optixRtnNj1PGWorkBoardID5 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the ID of the board on the fifth-priority working channel in an IF N+1 protection group." DEFVAL{ 255 } ::= { optixRtnNj1PGParameterEntry 20 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.30.1.21 optixRtnNj1PGWorkSubCardID5 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the ID of the subboard on the fifth-priority working channel in an IF N+1 protection group." DEFVAL{ 255 } ::= { optixRtnNj1PGParameterEntry 21 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.30.1.22 optixRtnNj1PGWorkPortID5 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the ID of the port on the fifth-priority working channel in an IF N+1 protection group." DEFVAL{ 255 } ::= { optixRtnNj1PGParameterEntry 22 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.30.1.23 optixRtnNj1PGWorkBoardID6 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the ID of the board on the sixth-priority working channel in an IF N+1 protection group." DEFVAL{ 255 } ::= { optixRtnNj1PGParameterEntry 23 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.30.1.24 optixRtnNj1PGWorkSubCardID6 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the ID of the subboard on the sixth-priority working channel in an IF N+1 protection group." DEFVAL{ 255 } ::= { optixRtnNj1PGParameterEntry 24 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.30.1.25 optixRtnNj1PGWorkPortID6 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the ID of the port on the sixth-priority working channel in an IF N+1 protection group." DEFVAL{ 255 } ::= { optixRtnNj1PGParameterEntry 25 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.30.1.26 optixRtnNj1PGWorkBoardID7 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the ID of the board on the seventh-priority working channel in an IF N+1 protection group." DEFVAL{ 255 } ::= { optixRtnNj1PGParameterEntry 26 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.30.1.27 optixRtnNj1PGWorkSubCardID7 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the ID of the subboard on the seventh-priority working channel in an IF N+1 protection group." DEFVAL{ 255 } ::= { optixRtnNj1PGParameterEntry 27 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.30.1.28 optixRtnNj1PGWorkPortID7 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the ID of the port on the seventh-priority working channel in an IF N+1 protection group." DEFVAL{ 255 } ::= { optixRtnNj1PGParameterEntry 28 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.30.1.29 optixRtnNj1PGStartProtocol OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "To start the current IF N+1 protection group" ::= { optixRtnNj1PGParameterEntry 29 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.30.1.30 optixRtnNj1PGStopProtocol OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "To stop the current IF N+1 protection group" ::= { optixRtnNj1PGParameterEntry 30 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.30.1.31 optixRtnNj1PGSwChannel OBJECT-TYPE SYNTAX Unsigned32 { null(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the switching channel of an IF N+1 protection group." ::= { optixRtnNj1PGParameterEntry 31 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.30.1.32 optixRtnNj1PGSwCmd OBJECT-TYPE SYNTAX OPTIXRtnNj1PGSwCmdType MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the switching type of an IF N+1 protection group." ::= { optixRtnNj1PGParameterEntry 32 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.30.1.33 optixRtnNj1PGWorkChunnelsInfo OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..16)) MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the information about the working channel in an IF N+1 protection group." ::= { optixRtnNj1PGParameterEntry 33 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.30.1.50 optixRtnNj1PGCfgRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the row status of an IF N+1 protection group." DEFVAL{ active } ::= { optixRtnNj1PGParameterEntry 50 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.40 optixRtnNj1PGStateTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnNj1PGStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Describes the corresponding channel status for an IF N+1 protection group, including the current working board and switching status of the protection group." ::= { optixRtnIFProtect 40 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.40.1 optixRtnNj1PGStateEntry OBJECT-TYPE SYNTAX OptixRtnNj1PGStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the channel status entry for an IF N+1 protection group." INDEX{ optixRtnNj1PGID,optixRtnNj1PGPuID } ::= { optixRtnNj1PGStateTable 1 } OptixRtnNj1PGStateEntry ::= SEQUENCE { optixRtnNj1PGPuID Unsigned32, optixRtnNj1PGSwitchRequest OPTIXRtnNj1PGSwitchRequestType, optixRtnNj1PGSwitchState OPTIXRtnNj1SwitchStateType, optixRtnNj1PGProtectPath Unsigned32, optixRtnNj1PGFarNearIndicate OPTIXRtnNj1PGFarNearType } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.40.1.1 optixRtnNj1PGPuID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the protection unit ID. Value range: 1 to 7" ::= { optixRtnNj1PGStateEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.40.1.2 optixRtnNj1PGSwitchRequest OBJECT-TYPE SYNTAX OPTIXRtnNj1PGSwitchRequestType MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the switching request. Values: 240: lockout 224: force 208: SF 176: SD 128: manual 96: wait to restore 64: exercise switching 32: reverse request 0: No request" ::= { optixRtnNj1PGStateEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.40.1.3 optixRtnNj1PGSwitchState OBJECT-TYPE SYNTAX OPTIXRtnNj1SwitchStateType MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the switching status. Values: 0: not started 1: idling 4: switching -1: protocol is starting" ::= { optixRtnNj1PGStateEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.40.1.4 optixRtnNj1PGProtectPath OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the protected working channel." ::= { optixRtnNj1PGStateEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.40.1.5 optixRtnNj1PGFarNearIndicate OBJECT-TYPE SYNTAX OPTIXRtnNj1PGFarNearType MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates far and near ends. Values: 0: none 1: near end 2: far end" ::= { optixRtnNj1PGStateEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.41 optixRtnExtNJ1PgTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnExtNJ1PgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the table of the enhanced N+1 protection group." ::= { optixRtnIFProtect 41 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.41.1 optixRtnExtNJ1PgEntry OBJECT-TYPE SYNTAX OptixRtnExtNJ1PgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the entry of the enhanced N+1 protection group." INDEX{ optixRtnExtNJ1PGID } ::= { optixRtnExtNJ1PgTable 1 } OptixRtnExtNJ1PgEntry ::= SEQUENCE { optixRtnExtNJ1PGID Unsigned32, optixRtnExtNJ1Mode OPTIXRtnExtNj1Mode, optixRtnExtNJ1ProtectChunnel OCTET STRING, optixRtnExtNJ1WorkChunnel OCTET STRING, optixRtnExtNJ1RowStatus RowStatus } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.41.1.1 optixRtnExtNJ1PGID OBJECT-TYPE SYNTAX Unsigned32 (1..7) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the ID of the enhanced N+1 protection group." ::= { optixRtnExtNJ1PgEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.41.1.2 optixRtnExtNJ1Mode OBJECT-TYPE SYNTAX OPTIXRtnExtNj1Mode MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the mode of the enhanced N+1 protection group." ::= { optixRtnExtNJ1PgEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.41.1.3 optixRtnExtNJ1ProtectChunnel OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..16)) MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates information about the protection channel in an enhanced N+1 protection group" ::= { optixRtnExtNJ1PgEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.41.1.4 optixRtnExtNJ1WorkChunnel OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates information about working channels in an enhanced N+1 protection group." ::= { optixRtnExtNJ1PgEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.41.1.5 optixRtnExtNJ1RowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the running status of the enhanced N+1 protection group." ::= { optixRtnExtNJ1PgEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.42 optixRtnNJ1ProtocolTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnNJ1ProtocolEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the table of the N+1 protocol." ::= { optixRtnIFProtect 42 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.42.1 optixRtnNJ1ProtocolEntry OBJECT-TYPE SYNTAX OptixRtnNJ1ProtocolEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the entry of the N+1 protocol." INDEX{ optixRtnNj1PGID } ::= { optixRtnNJ1ProtocolTable 1 } OptixRtnNJ1ProtocolEntry ::= SEQUENCE { optixRtnNj1ProtocolState OPTIXRtnNJ1ProtocolState, optixRtnNj1WTRTime Unsigned32, optixRtnNj1SDState OPTIXRtnEnableStateType } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.42.1.1 optixRtnNj1ProtocolState OBJECT-TYPE SYNTAX OPTIXRtnNJ1ProtocolState MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the stop/start status of the N+1 protocol." ::= { optixRtnNJ1ProtocolEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.42.1.2 optixRtnNj1WTRTime OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the WTR time of the N+1 protocol." ::= { optixRtnNJ1ProtocolEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.42.1.3 optixRtnNj1SDState OBJECT-TYPE SYNTAX OPTIXRtnEnableStateType MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the SD enable status of the N+1 protocol." ::= { optixRtnNJ1ProtocolEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.43 optixRtnNJ1SwitchTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnNJ1SwitchEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the table of external command-triggered switching of the N+1 protection group." ::= { optixRtnIFProtect 43 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.43.1 optixRtnNJ1SwitchEntry OBJECT-TYPE SYNTAX OptixRtnNJ1SwitchEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the entry of external command-triggered switching of the N+1 protection group." INDEX{ optixRtnNj1PGID, optixRtnNj1PGPuID } ::= { optixRtnNJ1SwitchTable 1 } OptixRtnNJ1SwitchEntry ::= SEQUENCE { optixRtnNj1SwitchChunnel OPTIXRtnNj1PGSwCmdType } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.43.1.1 optixRtnNj1SwitchChunnel OBJECT-TYPE SYNTAX OPTIXRtnNj1PGSwCmdType MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the switching channel of the N+1 protection group." ::= { optixRtnNJ1SwitchEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.45 optixRtnENJ1CCStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnENJ1CCStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the table of external command-triggered status of the EN+1 protection group." ::= { optixRtnIFProtect 45 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.45.1 optixRtnENJ1CCStatusEntry OBJECT-TYPE SYNTAX OptixRtnENJ1CCStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the entry of external command-triggered status of the EN+1 protection group." INDEX{ optixRtnNj1PGID, optixRtnNj1PGPuID } ::= { optixRtnENJ1CCStatusTable 1 } OptixRtnENJ1CCStatusEntry ::= SEQUENCE { optixRtnENJ1CCStatus INTEGER } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.45.1.3 optixRtnENJ1CCStatus OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the status of the EN+1 protection group." ::= { optixRtnENJ1CCStatusEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.50 optixRtnXPICPGParameterTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnXPICPGParameterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Describes configuration parameters for an IF XPIC protection group, including the boards in the horizon polarization direction and the vertical polarization direction." ::= { optixRtnIFProtect 50 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.50.1 optixRtnXPICPGParameterEntry OBJECT-TYPE SYNTAX OptixRtnXPICPGParameterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the parameter entry for an IF XPIC protection group." INDEX{ optixRtnXPICPGID } ::= { optixRtnXPICPGParameterTable 1 } OptixRtnXPICPGParameterEntry ::= SEQUENCE { optixRtnXPICPGID Unsigned32, optixRtnXPICPGHPolarBoardID Unsigned32, optixRtnXPICPGHPolarSubCardID Unsigned32, optixRtnXPICPGHPolarPortID Unsigned32, optixRtnXPICPGVPolarBoardID Unsigned32, optixRtnXPICPGVPolarSubCardID Unsigned32, optixRtnXPICPGVPolarPortID Unsigned32, optixRtnXPICPGOduFreq Unsigned32, optixRtnXPICPGCfgRowStatus RowStatus } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.50.1.1 optixRtnXPICPGID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the XPIC protection group ID." ::= { optixRtnXPICPGParameterEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.50.1.2 optixRtnXPICPGHPolarBoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the slot ID of an XPIC-enabled board in the horizon polarization direction." ::= { optixRtnXPICPGParameterEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.50.1.3 optixRtnXPICPGHPolarSubCardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the subboard ID of an XPIC-enabled board in the horizon polarization direction." DEFVAL{ 255 } ::= { optixRtnXPICPGParameterEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.50.1.4 optixRtnXPICPGHPolarPortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the port ID of an XPIC-enabled board in the horizon polarization direction." DEFVAL{ 1 } ::= { optixRtnXPICPGParameterEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.50.1.5 optixRtnXPICPGVPolarBoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the slot ID of an XPIC-enabled board in the vertical polarization direction." ::= { optixRtnXPICPGParameterEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.50.1.6 optixRtnXPICPGVPolarSubCardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the subboard ID of an XPIC-enabled board in the vertical polarization direction." DEFVAL{ 255 } ::= { optixRtnXPICPGParameterEntry 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.50.1.7 optixRtnXPICPGVPolarPortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the port ID of an XPIC-enabled board in the vertical polarization direction." DEFVAL{ 1 } ::= { optixRtnXPICPGParameterEntry 7 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.50.1.8 optixRtnXPICPGOduFreq OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the transmission frequency of an ODU board in an XPIC protection group. When frequencies of the transmitter/receiver at both ends match, signals can be received and transmitted successfully. Unit: kHz" ::= { optixRtnXPICPGParameterEntry 8 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.50.1.50 optixRtnXPICPGCfgRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the row status of an XPIC protection group." DEFVAL{ active } ::= { optixRtnXPICPGParameterEntry 50 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.60 optixRtnXPICPGAMParameterTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnXPICPGAMParameterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Describes corresponding AM parameters of an XPIC protection group." ::= { optixRtnIFProtect 60 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.60.1 optixRtnXPICPGAMParameterEntry OBJECT-TYPE SYNTAX OptixRtnXPICPGAMParameterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the AM parameter entry for an XPIC protection group." INDEX{ optixRtnXPICPGID } ::= { optixRtnXPICPGAMParameterTable 1 } OptixRtnXPICPGAMParameterEntry ::= SEQUENCE { optixRtnXPICPGBandWidth OPTIXRtnBandWidthType, optixRtnXPICPGAMEnableStatus OPTIXRtnEnableStateType, optixRtnXPICPGAMBottomMode OPTIXRtnModulateModeType, optixRtnXPICPGAMPeakMode OPTIXRtnModulateModeType, optixRtnXPICPGAMManualMode OPTIXRtnModulateModeType } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.60.1.1 optixRtnXPICPGBandWidth OBJECT-TYPE SYNTAX OPTIXRtnBandWidthType MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the channel bandwidth of an XPIC protection group. Values: 1: 3.5 Mbit/s 2: 7.0 Mbit/s 3: 14 Mbit/s 4: 28 Mbit/s 5: 40 Mbit/s 6: 56 Mbit/s" ::= { optixRtnXPICPGAMParameterEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.60.1.2 optixRtnXPICPGAMEnableStatus OBJECT-TYPE SYNTAX OPTIXRtnEnableStateType MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the enable status of the AM function in an XPIC protection group. Values: 0: disabled 1: enabled" DEFVAL{ 0 } ::= { optixRtnXPICPGAMParameterEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.60.1.3 optixRtnXPICPGAMBottomMode OBJECT-TYPE SYNTAX OPTIXRtnModulateModeType MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the lowest AM modulation scheme in an XPIC protection group." ::= { optixRtnXPICPGAMParameterEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.60.1.4 optixRtnXPICPGAMPeakMode OBJECT-TYPE SYNTAX OPTIXRtnModulateModeType MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the highest AM modulation scheme in an XPIC protection group." ::= { optixRtnXPICPGAMParameterEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.60.1.5 optixRtnXPICPGAMManualMode OBJECT-TYPE SYNTAX OPTIXRtnModulateModeType MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the manually specified modulation mode in an XPIC protection group." ::= { optixRtnXPICPGAMParameterEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.70 optixRtnXPICPGATPCParameterTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnXPICPGATPCParameterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Describes corresponding ATPC parameters of an XPIC protection group." ::= { optixRtnIFProtect 70 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.70.1 optixRtnXPICPGATPCParameterEntry OBJECT-TYPE SYNTAX OptixRtnXPICPGATPCParameterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the ATPC parameter entry for an XPIC protection group." INDEX{ optixRtnXPICPGID } ::= { optixRtnXPICPGATPCParameterTable 1 } OptixRtnXPICPGATPCParameterEntry ::= SEQUENCE { optixRtnXPICPGATPCEnableState OPTIXRtnEnableStateType, optixRtnXPICPGATPCStep Unsigned32, optixRtnXPICPGATPCHighThreshold Integer32, optixRtnXPICPGATPCLowThreshold Integer32, optixRtnXPICPGATPCAutoThresholdState OPTIXRtnEnableStateType } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.70.1.1 optixRtnXPICPGATPCEnableState OBJECT-TYPE SYNTAX OPTIXRtnEnableStateType MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the enable status of the ATPC function in an XPIC protection group. Values: 0: disabled 1: enabled" DEFVAL{ 0 } ::= { optixRtnXPICPGATPCParameterEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.70.1.2 optixRtnXPICPGATPCStep OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the ATPC adjustment step in an XPIC protection group. The parameter refers to every increase or decrease in the ODU transmit power. Value range: 10 to 50" ::= { optixRtnXPICPGATPCParameterEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.70.1.3 optixRtnXPICPGATPCHighThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the ATPC adjustment upper threshold in an XPIC protection group. When the receive signal level (RSL) is higher than the threshold, the transmitter automatically adjusts its transmit power. Signed type Value range: -850 to -200 Unit: 0.1 dBm" ::= { optixRtnXPICPGATPCParameterEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.70.1.4 optixRtnXPICPGATPCLowThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the ATPC adjustment lower threshold in an XPIC protection group. When the receive signal level (RSL) is lower than the threshold, the transmitter automatically adjusts its transmit power. Signed type Value range: -900 to -250 Unit: 0.1 dBm" ::= { optixRtnXPICPGATPCParameterEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.70.1.5 optixRtnXPICPGATPCAutoThresholdState OBJECT-TYPE SYNTAX OPTIXRtnEnableStateType MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the enable status of the ATPC automatic threshold configuration function in an XPIC protection group. The ATPC function enables the transmit power of a transmitter to automatically trace the change of the RSL at the receive end within the ATPC control range. The equipment automatically uses the preset ATPC upper and lower thresholds based on the working mode of the IF board. When the function is disabled, the manually set ATPC upper and lower thresholds are used. Values: 0: disabled 1: enabled" ::= { optixRtnXPICPGATPCParameterEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.80 optixRtnXPICPGOduParameterTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnXPICPGOduParameterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Describes corresponding ODU parameters of an XPIC protection group." ::= { optixRtnIFProtect 80 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.80.1 optixRtnXPICPGOduParameterEntry OBJECT-TYPE SYNTAX OptixRtnXPICPGOduParameterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the ODU parameter entry for an XPIC protection group." INDEX{ optixRtnXPICPGID } ::= { optixRtnXPICPGOduParameterTable 1 } OptixRtnXPICPGOduParameterEntry ::= SEQUENCE { optixRtnXPICPGOduTxFreq Unsigned32, optixRtnXPICPGOduTxPower Integer32, optixRtnXPICPGOduMaxTxpower Integer32, optixRtnXPICPGOduTRSpacing Unsigned32, optixRtnXPICPGOduWorkState OPTIXRtnOduWorkStateType } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.80.1.1 optixRtnXPICPGOduTxFreq OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the transmission frequency of an ODU board in an XPIC protection group. When frequencies of the transmitter/receiver at both ends match, signals can be received and transmitted successfully. Unit: kHz" ::= { optixRtnXPICPGOduParameterEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.80.1.2 optixRtnXPICPGOduTxPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the transmit power of an ODU board in an XPIC protection group. Signed type Unit: 0.1 dBm Value range: 100 to 350" ::= { optixRtnXPICPGOduParameterEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.80.1.3 optixRtnXPICPGOduMaxTxpower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the maximum transmit power of an ODU board in an XPIC protection group. When the AM function is disabled, the maximum transmit power in the current mode is returned. When the AM function is enabled, the maximum transmit power in the guaranteed capability modulation mode is returned." ::= { optixRtnXPICPGOduParameterEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.80.1.4 optixRtnXPICPGOduTRSpacing OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the T/R spacing of an ODU board in an XPIC protection group to avoid interference. Unit: kHz" ::= { optixRtnXPICPGOduParameterEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.80.1.5 optixRtnXPICPGOduWorkState OBJECT-TYPE SYNTAX OPTIXRtnOduWorkStateType MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the transmission status of the corresponding RF transmitter for an XPIC protection group. Values: 0: muted 1: unmuted" DEFVAL{ 1 } ::= { optixRtnXPICPGOduParameterEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.81 optixRtnXPICPGRFUFrequencyTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnXPICPGRFUFrequencyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the RFU frequency parameter of the XPIC workgroup." ::= { optixRtnIFProtect 81 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.81.1 optixRtnXPICPGRFUFrequencyEntry OBJECT-TYPE SYNTAX OptixRtnXPICPGRFUFrequencyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the entry of RFU frequency parameter of the XPIC workgroup." INDEX{ optixRtnXPICPGID } ::= { optixRtnXPICPGRFUFrequencyTable 1 } OptixRtnXPICPGRFUFrequencyEntry ::= SEQUENCE { optixRtnXPICPGRFURxFreq Unsigned32 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.81.1.1 optixRtnXPICPGRFURxFreq OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the receive frequency of the XPIC workgroup." ::= { optixRtnXPICPGRFUFrequencyEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.87 optixRtnXPICBdPolarMgr OBJECT IDENTIFIER ::= { optixRtnIFProtect 87 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.87.1 optixRtnBdPolarId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION " xpic group id" DEFVAL{ 1 } ::= { optixRtnXPICBdPolarMgr 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.87.2 optixRtnBdPolarHBid OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "H polar board id" DEFVAL{ 1 } ::= { optixRtnXPICBdPolarMgr 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.87.3 optixRtnBdPolarHSbid OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION " H polar subboard id" DEFVAL{ 255 } ::= { optixRtnXPICBdPolarMgr 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.87.4 optixRtnBdPolarHPid OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION " H polar port id" ::= { optixRtnXPICBdPolarMgr 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.87.5 optixRtnBdPolarVBid OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION " V polar board id" DEFVAL{ 1 } ::= { optixRtnXPICBdPolarMgr 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.87.6 optixRtnBdPolarVSbid OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION " V polar subboard id" DEFVAL{ 255 } ::= { optixRtnXPICBdPolarMgr 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.87.7 optixRtnBdPolarVPid OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION " V polar port id" ::= { optixRtnXPICBdPolarMgr 7 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.90 optixRtnPhyLagPGParameterTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnPhyLagPGParameterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Describes configuration parameters for the working board and protection board in a PLA protection group." ::= { optixRtnIFProtect 90 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.90.1 optixRtnPhyLagPGParameterEntry OBJECT-TYPE SYNTAX OptixRtnPhyLagPGParameterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates parameter entries for a PLA protection group." INDEX{ optixRtnPhyLagPGID } ::= { optixRtnPhyLagPGParameterTable 1 } OptixRtnPhyLagPGParameterEntry ::= SEQUENCE { optixRtnPhyLagPGID Unsigned32, optixRtnPhyLagPGType OPTIXRtnPhyLagPGType, optixRtnPhyLagPGMainBoardID Unsigned32, optixRtnPhyLagPGMainSubCardID Unsigned32, optixRtnPhyLagPGMainPortID Unsigned32, optixRtnPhyLagPGSlavePuNum Unsigned32, optixRtnPhyLagPGPu1BoardID Unsigned32, optixRtnPhyLagPGPu1SubCardID Unsigned32, optixRtnPhyLagPGPu1PortID Unsigned32, optixRtnPhyLagPGPu2BoardID Unsigned32, optixRtnPhyLagPGPu2SubCardID Unsigned32, optixRtnPhyLagPGPu2PortID Unsigned32, optixRtnPhyLagPGPu3BoardID Unsigned32, optixRtnPhyLagPGPu3SubCardID Unsigned32, optixRtnPhyLagPGPu3PortID Unsigned32, optixRtnPhyLagPGLinkThreshold Unsigned32, optixRtnPhyLagPGSlaveMemsInfo OCTET STRING, optixRtnPhyLagPGCfgRowStatus RowStatus } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.90.1.1 optixRtnPhyLagPGID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the protection group ID." ::= { optixRtnPhyLagPGParameterEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.90.1.2 optixRtnPhyLagPGType OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGType MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the protection group type. Values: 0: pla, 1: epla, 2: nbpla, 3: nbepla,4: epla plus,5: sepla" DEFVAL{ 0 } ::= { optixRtnPhyLagPGParameterEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.90.1.3 optixRtnPhyLagPGMainBoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the main unit slot ID." ::= { optixRtnPhyLagPGParameterEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.90.1.4 optixRtnPhyLagPGMainSubCardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the main subboard ID." ::= { optixRtnPhyLagPGParameterEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.90.1.5 optixRtnPhyLagPGMainPortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the main unit port ID." ::= { optixRtnPhyLagPGParameterEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.90.1.6 optixRtnPhyLagPGSlavePuNum OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the number of units. Value range: 1 to 15" DEFVAL{ 1 } ::= { optixRtnPhyLagPGParameterEntry 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.90.1.7 optixRtnPhyLagPGPu1BoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the unit 1 slot ID." ::= { optixRtnPhyLagPGParameterEntry 7 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.90.1.8 optixRtnPhyLagPGPu1SubCardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the unit 1 subboard ID." ::= { optixRtnPhyLagPGParameterEntry 8 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.90.1.9 optixRtnPhyLagPGPu1PortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the unit 1 port ID." ::= { optixRtnPhyLagPGParameterEntry 9 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.90.1.10 optixRtnPhyLagPGPu2BoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the unit 2 slot ID." DEFVAL{ 255 } ::= { optixRtnPhyLagPGParameterEntry 10 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.90.1.11 optixRtnPhyLagPGPu2SubCardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the unit 2 subboard ID." DEFVAL{ 255 } ::= { optixRtnPhyLagPGParameterEntry 11 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.90.1.12 optixRtnPhyLagPGPu2PortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the unit 2 port ID." DEFVAL{ 255 } ::= { optixRtnPhyLagPGParameterEntry 12 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.90.1.13 optixRtnPhyLagPGPu3BoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the unit 3 slot ID." DEFVAL{ 255 } ::= { optixRtnPhyLagPGParameterEntry 13 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.90.1.14 optixRtnPhyLagPGPu3SubCardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the unit 3 subboard ID." DEFVAL{ 255 } ::= { optixRtnPhyLagPGParameterEntry 14 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.90.1.15 optixRtnPhyLagPGPu3PortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the unit 3 port ID." DEFVAL{ 255 } ::= { optixRtnPhyLagPGParameterEntry 15 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.90.1.16 optixRtnPhyLagPGLinkThreshold OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the minimum number of activated links in a physical LAG." ::= { optixRtnPhyLagPGParameterEntry 16 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.90.1.17 optixRtnPhyLagPGSlaveMemsInfo OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..64)) MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the slave port information of a PLA protection group." ::= { optixRtnPhyLagPGParameterEntry 17 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.90.1.50 optixRtnPhyLagPGCfgRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the row status of a PLA protection group." DEFVAL{ active } ::= { optixRtnPhyLagPGParameterEntry 50 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.91 optixRtnPhyLagPGParameterExtTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnPhyLagPGParameterExtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Describes configuration parameters for the working board and protection board in the physical link aggregation group." ::= { optixRtnIFProtect 91 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.91.1 optixRtnPhyLagPGParameterExtEntry OBJECT-TYPE SYNTAX OptixRtnPhyLagPGParameterExtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates parameter entries for the physical link aggregation group." INDEX{ optixRtnPhyLagPGIDExt } ::= { optixRtnPhyLagPGParameterExtTable 1 } OptixRtnPhyLagPGParameterExtEntry ::= SEQUENCE { optixRtnPhyLagPGIDExt Unsigned32, optixRtnPhyLagPGTypeExt OPTIXRtnPhyLagPGType, optixRtnPhyLagPGCfgCapacity Unsigned32, optixRtnPhyLagPGMainBoardIDExt Unsigned32, optixRtnPhyLagPGMainSubCardIDExt Unsigned32, optixRtnPhyLagPGMainPortIDExt Unsigned32, optixRtnPhyLagPGSlaveMemsExtInfo OCTET STRING, optixRtnPhyLagPGLinkThresholdExt Unsigned32, optixRtnPhyLagPGMaxCapacity Unsigned32, optixRtnPhyLagPGCfgRowStatusExt RowStatus } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.91.1.1 optixRtnPhyLagPGIDExt OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the protection group ID of the physical link aggregation group." ::= { optixRtnPhyLagPGParameterExtEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.91.1.2 optixRtnPhyLagPGTypeExt OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGType MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the type of the physical link aggregation group. Values: 0: pla, 1: epla, 2: nbpla, 3: nbepla,4: epla plus,5: sepla" ::= { optixRtnPhyLagPGParameterExtEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.91.1.3 optixRtnPhyLagPGCfgCapacity OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the configuration capacity of the physical link aggregation group." DEFVAL{ 2500 } ::= { optixRtnPhyLagPGParameterExtEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.91.1.4 optixRtnPhyLagPGMainBoardIDExt OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the main unit slot ID of the physical link aggregation group." ::= { optixRtnPhyLagPGParameterExtEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.91.1.5 optixRtnPhyLagPGMainSubCardIDExt OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the main subboard ID of the physical link aggregation group." DEFVAL{ 255 } ::= { optixRtnPhyLagPGParameterExtEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.91.1.6 optixRtnPhyLagPGMainPortIDExt OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the main unit port ID of the physical link aggregation group." ::= { optixRtnPhyLagPGParameterExtEntry 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.91.1.7 optixRtnPhyLagPGSlaveMemsExtInfo OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..64)) MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the slave port information of the physical link aggregation group." ::= { optixRtnPhyLagPGParameterExtEntry 7 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.91.1.8 optixRtnPhyLagPGLinkThresholdExt OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the minimum number of activated links of the physical link aggregation group." DEFVAL{ 1 } ::= { optixRtnPhyLagPGParameterExtEntry 8 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.91.1.9 optixRtnPhyLagPGMaxCapacity OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the maximum capacity of the physical link aggregation group." ::= { optixRtnPhyLagPGParameterExtEntry 9 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.91.1.50 optixRtnPhyLagPGCfgRowStatusExt OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the row status of the physical link aggregation group." DEFVAL{ active } ::= { optixRtnPhyLagPGParameterExtEntry 50 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.92 optixRtnPhyLagPGSwitchEnableTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnPhyLagPGSwitchEnableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Describes the state of the hitless switching enable parameter in an EPLA protection group of 980L." ::= { optixRtnIFProtect 92 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.92.1 optixRtnPhyLagPGSwitchEnableEntry OBJECT-TYPE SYNTAX OptixRtnPhyLagPGSwitchEnableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the entry for enabling hitless switching for an EPLA protection group." INDEX{ optixRtnPhyLagSwitchEnablePGID,optixRtnPhyLagSwitchEnablePGType } ::= { optixRtnPhyLagPGSwitchEnableTable 1 } OptixRtnPhyLagPGSwitchEnableEntry ::= SEQUENCE { optixRtnPhyLagSwitchEnablePGID Unsigned32, optixRtnPhyLagSwitchEnablePGType OPTIXRtnPhyLagPGType, optixRtnPhyLagPGSwitchEnable INTEGER, optixRtnAddEplaMemberInfo OCTET STRING, optixRtnDelEplaMemberInfo OCTET STRING } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.92.1.1 optixRtnPhyLagSwitchEnablePGID OBJECT-TYPE SYNTAX Unsigned32 (1..12) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the ID of an EPLA protection group." ::= { optixRtnPhyLagPGSwitchEnableEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.92.1.2 optixRtnPhyLagSwitchEnablePGType OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGType MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the protection group type. Values: 0: pla 1: epla 2: nbpla 3: nbepla 4: eplaplus" ::= { optixRtnPhyLagPGSwitchEnableEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.92.1.3 optixRtnPhyLagPGSwitchEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the state of the hitless switching enable parameter in an EPLA protection group." DEFVAL{ 0 } ::= { optixRtnPhyLagPGSwitchEnableEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.92.1.4 optixRtnAddEplaMemberInfo OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates that members are added to a EPLA group in mode B." ::= { optixRtnPhyLagPGSwitchEnableEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.92.1.5 optixRtnDelEplaMemberInfo OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates that members are deleted from a EPLA group in mode B." ::= { optixRtnPhyLagPGSwitchEnableEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.93 optixRtnPhyLagServiceParaTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnPhyLagServiceParaEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the priority threshold for high-priority services in a EPLA group." ::= { optixRtnIFProtect 93 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.93.1 optixRtnPhyLagServiceParaEntry OBJECT-TYPE SYNTAX OptixRtnPhyLagServiceParaEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the priority threshold for high-priority services in a EPLA group." INDEX{ optixRtnPhyLagSerParaPGID,optixRtnPhyLagSerParaPGType } ::= { optixRtnPhyLagServiceParaTable 1 } OptixRtnPhyLagServiceParaEntry ::= SEQUENCE { optixRtnPhyLagSerParaPGID Unsigned32, optixRtnPhyLagSerParaPGType OPTIXRtnPhyLagPGType, optixRtnPhyLagServicePriorityThreshold Unsigned32, optixRtnConfigServScheduleMode INTEGER, optixRtnWorkingServScheduleMode INTEGER, optixRtnPhyMemberAttrInfo OCTET STRING } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.93.1.1 optixRtnPhyLagSerParaPGID OBJECT-TYPE SYNTAX Unsigned32 (1..12) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the protection group ID." ::= { optixRtnPhyLagServiceParaEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.93.1.2 optixRtnPhyLagSerParaPGType OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGType MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the protection group type." ::= { optixRtnPhyLagServiceParaEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.93.1.3 optixRtnPhyLagServicePriorityThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the priority threshold for services." DEFVAL{ 5 } ::= { optixRtnPhyLagServiceParaEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.93.1.4 optixRtnConfigServScheduleMode OBJECT-TYPE SYNTAX INTEGER { modeA(0), modeB(1), modeAAccess(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the config prority of the slave unit.0: modeA; 1: modeB;2:modeAAccess" DEFVAL{ 1 } ::= { optixRtnPhyLagServiceParaEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.93.1.5 optixRtnWorkingServScheduleMode OBJECT-TYPE SYNTAX INTEGER { modeA(0), modeB(1), modeAAccess(2), unknown(-1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the scheduling mode for the working service. 0: modeA; 1: modeB;2:modeAAccess; 0xff: unknown" ::= { optixRtnPhyLagServiceParaEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.93.1.6 optixRtnPhyMemberAttrInfo OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates tht arrtibute of the slave unit" ::= { optixRtnPhyLagServiceParaEntry 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.94 optixRtnPhyLagMemberPriTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnPhyLagMemberPriEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Queries priorities of members in a EPLA group." ::= { optixRtnIFProtect 94 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.94.1 optixRtnPhyLagMemberPriEntry OBJECT-TYPE SYNTAX OptixRtnPhyLagMemberPriEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Queries priorities of members in a EPLA group." INDEX{ optixRtnPhyLagMemPriPGID,optixRtnPhyLagMemPriPGType } ::= { optixRtnPhyLagMemberPriTable 1 } OptixRtnPhyLagMemberPriEntry ::= SEQUENCE { optixRtnPhyLagMemPriPGID Unsigned32, optixRtnPhyLagMemPriPGType OPTIXRtnPhyLagPGType, optixRtnPhyLagMemBoardId Unsigned32, optixRtnPhyLagMemSubCardId Unsigned32, optixRtnPhyLagMemPortId Unsigned32, optixRtnPhyLagMemChannelId Unsigned32, optixRtnPhyLagConfigPriority INTEGER, optixRtnPhyLagWorkingPriority INTEGER } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.94.1.1 optixRtnPhyLagMemPriPGID OBJECT-TYPE SYNTAX Unsigned32 (1..12) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the protection group ID." ::= { optixRtnPhyLagMemberPriEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.94.1.2 optixRtnPhyLagMemPriPGType OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGType MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the protection group type." ::= { optixRtnPhyLagMemberPriEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.94.1.3 optixRtnPhyLagMemBoardId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the slot ID of the slave unit." ::= { optixRtnPhyLagMemberPriEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.94.1.4 optixRtnPhyLagMemSubCardId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the subboard ID of the slave unit." ::= { optixRtnPhyLagMemberPriEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.94.1.5 optixRtnPhyLagMemPortId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the port ID of the slave unit." ::= { optixRtnPhyLagMemberPriEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.94.1.6 optixRtnPhyLagMemChannelId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the channel ID of the salve unit." ::= { optixRtnPhyLagMemberPriEntry 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.94.1.7 optixRtnPhyLagConfigPriority OBJECT-TYPE SYNTAX INTEGER { auto(0), lowPri(1), highPri(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the config prority of the slave unit.0: auto; 1: lowPri; 2: highPri;" DEFVAL{ 0 } ::= { optixRtnPhyLagMemberPriEntry 7 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.94.1.8 optixRtnPhyLagWorkingPriority OBJECT-TYPE SYNTAX INTEGER { auto(0), lowPri(1), highPri(2), unknown(-1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the scheduling mode of the slave unit. 0: auto; 1: lowPri; 2: highPri; 0xff: unknown;" ::= { optixRtnPhyLagMemberPriEntry 8 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.96 optixRtnPhyLagMemberStateTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnPhyLagMemberStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates status of members in a PLA group." ::= { optixRtnIFProtect 96 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.96.1 optixRtnPhyLagMemberStateEntry OBJECT-TYPE SYNTAX OptixRtnPhyLagMemberStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates status of members in a PLA group." INDEX{ optixRtnPhyLagMemStaPGId } ::= { optixRtnPhyLagMemberStateTable 1 } OptixRtnPhyLagMemberStateEntry ::= SEQUENCE { optixRtnPhyLagMemStaPGId Unsigned32, optixRtnPhyLagMemStateInfo OCTET STRING } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.96.1.1 optixRtnPhyLagMemStaPGId OBJECT-TYPE SYNTAX Unsigned32 (1..12) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the protection group ID." ::= { optixRtnPhyLagMemberStateEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.96.1.2 optixRtnPhyLagMemStateInfo OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the state information of the slave unit" ::= { optixRtnPhyLagMemberStateEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.97 optixRtnPhyLagSdbPGParameterTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnPhyLagSdbPGParameterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Describes configuration parameters for the working board and protection board in the PLA group." ::= { optixRtnIFProtect 97 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.97.1 optixRtnPhyLagSdbPGParameterEntry OBJECT-TYPE SYNTAX OptixRtnPhyLagSdbPGParameterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates parameter entries for a PLA group." INDEX{ optixRtnPhyLagSdbPGID } ::= { optixRtnPhyLagSdbPGParameterTable 1 } OptixRtnPhyLagSdbPGParameterEntry ::= SEQUENCE { optixRtnPhyLagSdbPGID Unsigned32, optixRtnPhyLagSdbPGType OPTIXRtnPhyLagPGType, optixRtnPhyLagSdbPGCfgCapacity Unsigned32, optixRtnPhyLagSdbPGMainBoardID Unsigned32, optixRtnPhyLagSdbPGMainSubCardID Unsigned32, optixRtnPhyLagSdbPGMainPortID Unsigned32, optixRtnPhyLagSdbPGSlaveMemsInfo OCTET STRING, optixRtnPhyLagSdbPGSlaveMemsAttrInfo OCTET STRING, optixRtnPhyLagSdbPGCfgRowStatus RowStatus } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.97.1.1 optixRtnPhyLagSdbPGID OBJECT-TYPE SYNTAX Unsigned32 (1..12) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the PLA group ID." ::= { optixRtnPhyLagSdbPGParameterEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.97.1.2 optixRtnPhyLagSdbPGType OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGType MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the PLA group type." ::= { optixRtnPhyLagSdbPGParameterEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.97.1.3 optixRtnPhyLagSdbPGCfgCapacity OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the configuration capacity of a PLA group." DEFVAL{ 2500 } ::= { optixRtnPhyLagSdbPGParameterEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.97.1.4 optixRtnPhyLagSdbPGMainBoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the main unit slot ID of a PLA group." ::= { optixRtnPhyLagSdbPGParameterEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.97.1.5 optixRtnPhyLagSdbPGMainSubCardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the main subboard ID of a PLA group." DEFVAL{ 255 } ::= { optixRtnPhyLagSdbPGParameterEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.97.1.6 optixRtnPhyLagSdbPGMainPortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the main unit port ID of a PLA group." ::= { optixRtnPhyLagSdbPGParameterEntry 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.97.1.7 optixRtnPhyLagSdbPGSlaveMemsInfo OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the slave port information of a PLA group." ::= { optixRtnPhyLagSdbPGParameterEntry 7 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.97.1.8 optixRtnPhyLagSdbPGSlaveMemsAttrInfo OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates information about ports and channels of slave members in a PLA group." ::= { optixRtnPhyLagSdbPGParameterEntry 8 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.97.1.50 optixRtnPhyLagSdbPGCfgRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the row status of a PLA group." DEFVAL{ active } ::= { optixRtnPhyLagSdbPGParameterEntry 50 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.98 optixRtnCascadingSDBPhyLagPGParameterTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnCascadingSDBPhyLagPGParameterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "To create an EPLA protection group" ::= { optixRtnIFProtect 98 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.98.1 optixRtnCascadingSDBPhyLagPGParameterEntry OBJECT-TYPE SYNTAX OptixRtnCascadingSDBPhyLagPGParameterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "To create an EPLA protection group" INDEX{ optixRtnCascadingSDBPhyLagPGId } ::= { optixRtnCascadingSDBPhyLagPGParameterTable 1 } OptixRtnCascadingSDBPhyLagPGParameterEntry ::= SEQUENCE { optixRtnCascadingSDBPhyLagPGId Unsigned32, optixRtnCascadingSDBPhyLagPGType INTEGER, optixRtnCascadingSDBPhyLagPGCapacity Unsigned32, optixRtnCascadingSDBPhyLagPGMasterBoardId Unsigned32, optixRtnCascadingSDBPhyLagPGMasterSubCardId Unsigned32, optixRtnCascadingSDBPhyLagPGMasterPortId Unsigned32, optixRtnCascadingSDBPhyLagPGInfo OCTET STRING, optixRtnCascadingSDBPhyLagPGSlaveType INTEGER, optixRtnCascadingSDBPhyLagPGSlaveMemMapInfo OCTET STRING, optixRtnCascadingSDBPhyLagPGRowStatus RowStatus } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.98.1.1 optixRtnCascadingSDBPhyLagPGId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the LAG ID" ::= { optixRtnCascadingSDBPhyLagPGParameterEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.98.1.2 optixRtnCascadingSDBPhyLagPGType OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGType MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the LAG type" ::= { optixRtnCascadingSDBPhyLagPGParameterEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.98.1.3 optixRtnCascadingSDBPhyLagPGCapacity OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the bandwidth capacity (unit: M). Value range: 1000-7000 Step: 100 Default: 2500" DEFVAL{ 2500 } ::= { optixRtnCascadingSDBPhyLagPGParameterEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.98.1.4 optixRtnCascadingSDBPhyLagPGMasterBoardId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the slot ID of the primary port." ::= { optixRtnCascadingSDBPhyLagPGParameterEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.98.1.5 optixRtnCascadingSDBPhyLagPGMasterSubCardId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the subboard ID of the primary port." ::= { optixRtnCascadingSDBPhyLagPGParameterEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.98.1.6 optixRtnCascadingSDBPhyLagPGMasterPortId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the primary port ID." ::= { optixRtnCascadingSDBPhyLagPGParameterEntry 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.98.1.7 optixRtnCascadingSDBPhyLagPGInfo OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the information of secondary ports." ::= { optixRtnCascadingSDBPhyLagPGParameterEntry 7 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.98.1.8 optixRtnCascadingSDBPhyLagPGSlaveType OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGType MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the LAG type" ::= { optixRtnCascadingSDBPhyLagPGParameterEntry 8 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.98.1.9 optixRtnCascadingSDBPhyLagPGSlaveMemMapInfo OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the mapping between EPLA members and service ports" ::= { optixRtnCascadingSDBPhyLagPGParameterEntry 9 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.98.1.50 optixRtnCascadingSDBPhyLagPGRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the row status." DEFVAL{ active } ::= { optixRtnCascadingSDBPhyLagPGParameterEntry 50 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100 optixRtnPhyLagPGStateTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnPhyLagPGStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Describes parameters about a PLA protection group, including the current working board and the switching status of a protection group." ::= { optixRtnIFProtect 100 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1 optixRtnPhyLagPGStateEntry OBJECT-TYPE SYNTAX OptixRtnPhyLagPGStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates status entry for a PLA protection group." INDEX{ optixRtnPhyLagPGID } ::= { optixRtnPhyLagPGStateTable 1 } OptixRtnPhyLagPGStateEntry ::= SEQUENCE { optixRtnPhyLagPGStateMainBoardID Unsigned32, optixRtnPhyLagPGStateMainSubCardID Unsigned32, optixRtnPhyLagPGStateMainPortID Unsigned32, optixRtnPhyLagPGMainHardStatus OPTIXRtnPhyLagPGStatus, optixRtnPhyLagPGMainLinkStatus OPTIXRtnPhyLagPGStatus, optixRtnPhyLagPGMainPuWorkStatus OPTIXRtnPhyLagPGStateWorkStatus, optixRtnPhyLagPGStateSlavePuNum Unsigned32, optixRtnPhyLagPGStatePu1BoardID Unsigned32, optixRtnPhyLagPGStatePu1SubCardID Unsigned32, optixRtnPhyLagPGStatePu1PortID Unsigned32, optixRtnPhyLagPGStatePu1HardStatus OPTIXRtnPhyLagPGStatus, optixRtnPhyLagPGStatePu1LinkStatus OPTIXRtnPhyLagPGStatus, optixRtnPhyLagPGStatePu1WorkStatus OPTIXRtnPhyLagPGStateWorkStatus, optixRtnPhyLagPGStatePu2BoardID Unsigned32, optixRtnPhyLagPGStatePu2SubCardID Unsigned32, optixRtnPhyLagPGStatePu2PortID Unsigned32, optixRtnPhyLagPGStatePu2HardStatus OPTIXRtnPhyLagPGStatus, optixRtnPhyLagPGStatePu2LinkStatus OPTIXRtnPhyLagPGStatus, optixRtnPhyLagPGStatePu2WorkStatus OPTIXRtnPhyLagPGStateWorkStatus, optixRtnPhyLagPGStatePu3BoardID Unsigned32, optixRtnPhyLagPGStatePu3SubCardID Unsigned32, optixRtnPhyLagPGStatePu3PortID Unsigned32, optixRtnPhyLagPGStatePu3HardStatus OPTIXRtnPhyLagPGStatus, optixRtnPhyLagPGStatePu3LinkStatus OPTIXRtnPhyLagPGStatus, optixRtnPhyLagPGStatePu3WorkStatus OPTIXRtnPhyLagPGStateWorkStatus, optixRtnPhyLagPGStatePu4BoardID Unsigned32, optixRtnPhyLagPGStatePu4SubCardID Unsigned32, optixRtnPhyLagPGStatePu4PortID Unsigned32, optixRtnPhyLagPGStatePu4HardStatus OPTIXRtnPhyLagPGStatus, optixRtnPhyLagPGStatePu4LinkStatus OPTIXRtnPhyLagPGStatus, optixRtnPhyLagPGStatePu4WorkStatus OPTIXRtnPhyLagPGStateWorkStatus, optixRtnPhyLagPGStatePu5BoardID Unsigned32, optixRtnPhyLagPGStatePu5SubCardID Unsigned32, optixRtnPhyLagPGStatePu5PortID Unsigned32, optixRtnPhyLagPGStatePu5HardStatus OPTIXRtnPhyLagPGStatus, optixRtnPhyLagPGStatePu5LinkStatus OPTIXRtnPhyLagPGStatus, optixRtnPhyLagPGStatePu5WorkStatus OPTIXRtnPhyLagPGStateWorkStatus, optixRtnPhyLagPGStatePu6BoardID Unsigned32, optixRtnPhyLagPGStatePu6SubCardID Unsigned32, optixRtnPhyLagPGStatePu6PortID Unsigned32, optixRtnPhyLagPGStatePu6HardStatus OPTIXRtnPhyLagPGStatus, optixRtnPhyLagPGStatePu6LinkStatus OPTIXRtnPhyLagPGStatus, optixRtnPhyLagPGStatePu6WorkStatus OPTIXRtnPhyLagPGStateWorkStatus, optixRtnPhyLagPGStatePu7BoardID Unsigned32, optixRtnPhyLagPGStatePu7SubCardID Unsigned32, optixRtnPhyLagPGStatePu7PortID Unsigned32, optixRtnPhyLagPGStatePu7HardStatus OPTIXRtnPhyLagPGStatus, optixRtnPhyLagPGStatePu7LinkStatus OPTIXRtnPhyLagPGStatus, optixRtnPhyLagPGStatePu7WorkStatus OPTIXRtnPhyLagPGStateWorkStatus, optixRtnPhyLagPGStatePu8BoardID Unsigned32, optixRtnPhyLagPGStatePu8SubCardID Unsigned32, optixRtnPhyLagPGStatePu8PortID Unsigned32, optixRtnPhyLagPGStatePu8HardStatus OPTIXRtnPhyLagPGStatus, optixRtnPhyLagPGStatePu8LinkStatus OPTIXRtnPhyLagPGStatus, optixRtnPhyLagPGStatePu8WorkStatus OPTIXRtnPhyLagPGStateWorkStatus, optixRtnPhyLagPGStatePu9BoardID Unsigned32, optixRtnPhyLagPGStatePu9SubCardID Unsigned32, optixRtnPhyLagPGStatePu9PortID Unsigned32, optixRtnPhyLagPGStatePu9HardStatus OPTIXRtnPhyLagPGStatus, optixRtnPhyLagPGStatePu9LinkStatus OPTIXRtnPhyLagPGStatus, optixRtnPhyLagPGStatePu9WorkStatus OPTIXRtnPhyLagPGStateWorkStatus, optixRtnPhyLagPGStatePu10BoardID Unsigned32, optixRtnPhyLagPGStatePu10SubCardID Unsigned32, optixRtnPhyLagPGStatePu10PortID Unsigned32, optixRtnPhyLagPGStatePu10HardStatus OPTIXRtnPhyLagPGStatus, optixRtnPhyLagPGStatePu10LinkStatus OPTIXRtnPhyLagPGStatus, optixRtnPhyLagPGStatePu10WorkStatus OPTIXRtnPhyLagPGStateWorkStatus, optixRtnPhyLagPGStatePu11BoardID Unsigned32, optixRtnPhyLagPGStatePu11SubCardID Unsigned32, optixRtnPhyLagPGStatePu11PortID Unsigned32, optixRtnPhyLagPGStatePu11HardStatus OPTIXRtnPhyLagPGStatus, optixRtnPhyLagPGStatePu11LinkStatus OPTIXRtnPhyLagPGStatus, optixRtnPhyLagPGStatePu11WorkStatus OPTIXRtnPhyLagPGStateWorkStatus } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.1 optixRtnPhyLagPGStateMainBoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the main unit slot ID." ::= { optixRtnPhyLagPGStateEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.2 optixRtnPhyLagPGStateMainSubCardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the main unit subboard ID." ::= { optixRtnPhyLagPGStateEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.3 optixRtnPhyLagPGStateMainPortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the main unit port ID." ::= { optixRtnPhyLagPGStateEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.4 optixRtnPhyLagPGMainHardStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the hardware status of the main unit. The values: 0: normal 1: abnormal -1: unknown" ::= { optixRtnPhyLagPGStateEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.5 optixRtnPhyLagPGMainLinkStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the link status of the main unit. Values: 0: normal 1: abnormal -1: unknown" ::= { optixRtnPhyLagPGStateEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.6 optixRtnPhyLagPGMainPuWorkStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStateWorkStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the working status of the main unit. Values: 0: slave port 1: main port" ::= { optixRtnPhyLagPGStateEntry 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.7 optixRtnPhyLagPGStateSlavePuNum OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the number of slave units. Value range: 1 to 15" ::= { optixRtnPhyLagPGStateEntry 7 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.8 optixRtnPhyLagPGStatePu1BoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 1 slot ID." ::= { optixRtnPhyLagPGStateEntry 8 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.9 optixRtnPhyLagPGStatePu1SubCardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 1 subboard ID." ::= { optixRtnPhyLagPGStateEntry 9 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.10 optixRtnPhyLagPGStatePu1PortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 1 port ID." ::= { optixRtnPhyLagPGStateEntry 10 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.11 optixRtnPhyLagPGStatePu1HardStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 1 hardware status. Values: 0: normal 1: abnormal -1: unknown" ::= { optixRtnPhyLagPGStateEntry 11 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.12 optixRtnPhyLagPGStatePu1LinkStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 1 link status. Values: 0: normal 1: abnormal -1: unknown" ::= { optixRtnPhyLagPGStateEntry 12 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.13 optixRtnPhyLagPGStatePu1WorkStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStateWorkStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 1 working status. Values: 0: slave port 1: main port" ::= { optixRtnPhyLagPGStateEntry 13 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.14 optixRtnPhyLagPGStatePu2BoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 2 slot ID." ::= { optixRtnPhyLagPGStateEntry 14 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.15 optixRtnPhyLagPGStatePu2SubCardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 2 subboard ID." ::= { optixRtnPhyLagPGStateEntry 15 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.16 optixRtnPhyLagPGStatePu2PortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 2 port ID." ::= { optixRtnPhyLagPGStateEntry 16 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.17 optixRtnPhyLagPGStatePu2HardStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 2 hardware status. Values: 0: normal 1: abnormal -1: unknown" ::= { optixRtnPhyLagPGStateEntry 17 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.18 optixRtnPhyLagPGStatePu2LinkStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 2 link status. Values: 0: normal 1: abnormal -1: unknown" ::= { optixRtnPhyLagPGStateEntry 18 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.19 optixRtnPhyLagPGStatePu2WorkStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStateWorkStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 2 working status. Values: 0: slave port 1: main port" ::= { optixRtnPhyLagPGStateEntry 19 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.20 optixRtnPhyLagPGStatePu3BoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 3 slot ID." ::= { optixRtnPhyLagPGStateEntry 20 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.21 optixRtnPhyLagPGStatePu3SubCardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 3 subboard ID." ::= { optixRtnPhyLagPGStateEntry 21 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.22 optixRtnPhyLagPGStatePu3PortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 3 port ID." ::= { optixRtnPhyLagPGStateEntry 22 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.23 optixRtnPhyLagPGStatePu3HardStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 3 hardware status. Values: 0: normal 1: abnormal -1: unknown" ::= { optixRtnPhyLagPGStateEntry 23 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.24 optixRtnPhyLagPGStatePu3LinkStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 3 link status. Values: 0: normal 1: abnormal -1: unknown" ::= { optixRtnPhyLagPGStateEntry 24 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.25 optixRtnPhyLagPGStatePu3WorkStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStateWorkStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 3 working status. Values: 0: slave port 1: main port" ::= { optixRtnPhyLagPGStateEntry 25 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.26 optixRtnPhyLagPGStatePu4BoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 4 slot ID." ::= { optixRtnPhyLagPGStateEntry 26 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.27 optixRtnPhyLagPGStatePu4SubCardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 4 subboard ID." ::= { optixRtnPhyLagPGStateEntry 27 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.28 optixRtnPhyLagPGStatePu4PortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 4 port ID." ::= { optixRtnPhyLagPGStateEntry 28 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.29 optixRtnPhyLagPGStatePu4HardStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 4 hardware status. Values: 0: normal 1: abnormal -1: unknown" ::= { optixRtnPhyLagPGStateEntry 29 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.30 optixRtnPhyLagPGStatePu4LinkStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 4 link status. Values: 0: normal 1: abnormal -1: unknown" ::= { optixRtnPhyLagPGStateEntry 30 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.31 optixRtnPhyLagPGStatePu4WorkStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStateWorkStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 4 working status. Values: 0: slave port 1: main port" ::= { optixRtnPhyLagPGStateEntry 31 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.32 optixRtnPhyLagPGStatePu5BoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 5 slot ID." ::= { optixRtnPhyLagPGStateEntry 32 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.33 optixRtnPhyLagPGStatePu5SubCardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 5 subboard ID." ::= { optixRtnPhyLagPGStateEntry 33 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.34 optixRtnPhyLagPGStatePu5PortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 5 port ID." ::= { optixRtnPhyLagPGStateEntry 34 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.35 optixRtnPhyLagPGStatePu5HardStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 5 hardware status. Values: 0: normal 1: abnormal -1: unknown" ::= { optixRtnPhyLagPGStateEntry 35 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.36 optixRtnPhyLagPGStatePu5LinkStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 5 link status. Values: 0: normal 1: abnormal -1: unknown" ::= { optixRtnPhyLagPGStateEntry 36 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.37 optixRtnPhyLagPGStatePu5WorkStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStateWorkStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 5 working status. Values: 0: slave port 1: main port" ::= { optixRtnPhyLagPGStateEntry 37 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.38 optixRtnPhyLagPGStatePu6BoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 6 slot ID." ::= { optixRtnPhyLagPGStateEntry 38 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.39 optixRtnPhyLagPGStatePu6SubCardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 6 subboard ID." ::= { optixRtnPhyLagPGStateEntry 39 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.40 optixRtnPhyLagPGStatePu6PortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 6 port ID." ::= { optixRtnPhyLagPGStateEntry 40 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.41 optixRtnPhyLagPGStatePu6HardStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 6 hardware status. Values: 0: normal 1: abnormal -1: unknown" ::= { optixRtnPhyLagPGStateEntry 41 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.42 optixRtnPhyLagPGStatePu6LinkStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 6 link status. Values: 0: normal 1: abnormal -1: unknown" ::= { optixRtnPhyLagPGStateEntry 42 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.43 optixRtnPhyLagPGStatePu6WorkStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStateWorkStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 6 working status. Values: 0: slave port 1: main port" ::= { optixRtnPhyLagPGStateEntry 43 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.44 optixRtnPhyLagPGStatePu7BoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 7 slot ID." ::= { optixRtnPhyLagPGStateEntry 44 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.45 optixRtnPhyLagPGStatePu7SubCardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 7 subboard ID." ::= { optixRtnPhyLagPGStateEntry 45 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.46 optixRtnPhyLagPGStatePu7PortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 7 port ID." ::= { optixRtnPhyLagPGStateEntry 46 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.47 optixRtnPhyLagPGStatePu7HardStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 7 hardware status. Values: 0: normal 1: abnormal -1: unknown" ::= { optixRtnPhyLagPGStateEntry 47 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.48 optixRtnPhyLagPGStatePu7LinkStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 7 link status. Values: 0: normal 1: abnormal -1: unknown" ::= { optixRtnPhyLagPGStateEntry 48 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.49 optixRtnPhyLagPGStatePu7WorkStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStateWorkStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 7 working status. Values: 0: slave port 1: main port" ::= { optixRtnPhyLagPGStateEntry 49 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.50 optixRtnPhyLagPGStatePu8BoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 8 slot ID." ::= { optixRtnPhyLagPGStateEntry 50 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.51 optixRtnPhyLagPGStatePu8SubCardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 8 subboard ID." ::= { optixRtnPhyLagPGStateEntry 51 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.52 optixRtnPhyLagPGStatePu8PortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 8 port ID." ::= { optixRtnPhyLagPGStateEntry 52 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.53 optixRtnPhyLagPGStatePu8HardStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 8 hardware status. Values: 0: normal 1: abnormal -1: unknown" ::= { optixRtnPhyLagPGStateEntry 53 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.54 optixRtnPhyLagPGStatePu8LinkStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 8 link status. Values: 0: normal 1: abnormal -1: unknown" ::= { optixRtnPhyLagPGStateEntry 54 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.55 optixRtnPhyLagPGStatePu8WorkStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStateWorkStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 8 working status. Values: 0: slave port 1: main port" ::= { optixRtnPhyLagPGStateEntry 55 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.56 optixRtnPhyLagPGStatePu9BoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 9 slot ID." ::= { optixRtnPhyLagPGStateEntry 56 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.57 optixRtnPhyLagPGStatePu9SubCardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 9 subboard ID." ::= { optixRtnPhyLagPGStateEntry 57 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.58 optixRtnPhyLagPGStatePu9PortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 9 port ID." ::= { optixRtnPhyLagPGStateEntry 58 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.59 optixRtnPhyLagPGStatePu9HardStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 9 hardware status. Values: 0: normal 1: abnormal -1: unknown" ::= { optixRtnPhyLagPGStateEntry 59 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.60 optixRtnPhyLagPGStatePu9LinkStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 9 link status. Values: 0: normal 1: abnormal -1: unknown" ::= { optixRtnPhyLagPGStateEntry 60 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.61 optixRtnPhyLagPGStatePu9WorkStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStateWorkStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 9 working status. Values: 0: slave port 1: main port" ::= { optixRtnPhyLagPGStateEntry 61 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.62 optixRtnPhyLagPGStatePu10BoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 10 slot ID." ::= { optixRtnPhyLagPGStateEntry 62 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.63 optixRtnPhyLagPGStatePu10SubCardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 10 subboard ID." ::= { optixRtnPhyLagPGStateEntry 63 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.64 optixRtnPhyLagPGStatePu10PortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 10 port ID." ::= { optixRtnPhyLagPGStateEntry 64 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.65 optixRtnPhyLagPGStatePu10HardStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 10 hardware status. Values: 0: normal 1: abnormal -1: unknown" ::= { optixRtnPhyLagPGStateEntry 65 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.66 optixRtnPhyLagPGStatePu10LinkStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 10 link status. Values: 0: normal 1: abnormal -1: unknown" ::= { optixRtnPhyLagPGStateEntry 66 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.67 optixRtnPhyLagPGStatePu10WorkStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStateWorkStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 10 working status. Values: 0: slave port 1: main port" ::= { optixRtnPhyLagPGStateEntry 67 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.68 optixRtnPhyLagPGStatePu11BoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 11 slot ID." ::= { optixRtnPhyLagPGStateEntry 68 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.69 optixRtnPhyLagPGStatePu11SubCardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 11 subboard ID." ::= { optixRtnPhyLagPGStateEntry 69 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.70 optixRtnPhyLagPGStatePu11PortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 11 port ID." ::= { optixRtnPhyLagPGStateEntry 70 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.71 optixRtnPhyLagPGStatePu11HardStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 11 hardware status. Values: 0: normal 1: abnormal -1: unknown" ::= { optixRtnPhyLagPGStateEntry 71 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.72 optixRtnPhyLagPGStatePu11LinkStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 11 link status. Values: 0: normal 1: abnormal -1: unknown" ::= { optixRtnPhyLagPGStateEntry 72 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.100.1.73 optixRtnPhyLagPGStatePu11WorkStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStateWorkStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 11 working status. Values: 0: slave port 1: main port" ::= { optixRtnPhyLagPGStateEntry 73 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.110 optixRtnCascading1j1PGParameterTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnCascading1j1PGParameterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Describes parameters about a cascading IF 1+1 protection group, including the IF board used in the protection group and the role of the IF board in the protection group." ::= { optixRtnIFProtect 110 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.110.1 optixRtnCascading1j1PGParameterEntry OBJECT-TYPE SYNTAX OptixRtnCascading1j1PGParameterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the parameter entry for a cascading IF 1+1 protection group." INDEX{ optixRtnCascading1j1PGID } ::= { optixRtnCascading1j1PGParameterTable 1 } OptixRtnCascading1j1PGParameterEntry ::= SEQUENCE { optixRtnCascading1j1PGID Unsigned32, optixRtnCascading1j1PGIFBoardID Unsigned32, optixRtnCascading1j1PGIFSubCardID Unsigned32, optixRtnCascading1j1PGIFPort Unsigned32, optixRtnCascading1j1PGRole OPTIXRtnCascading1j1PGRoleType, optixRtnCascading1j1PGWorkMode OPTIXRtn1j1PGWorkModeType, optixRtnCascading1j1PGRevertiveMode OPTIXRtnRvtModeType, optixRtnCascading1j1PGWTRTime Unsigned32, optixRtnCascading1j1PGRDISwEnableState OPTIXRtnEnableStateType, optixRtnCascading1j1PGProtectType OPTIXRtnCascading1j1PGProtectType, optixRtnCascading1j1PGSlaveMemsInfo OCTET STRING, optixRtnCascading1j1PGSwCmd OPTIXRtn1j1PGSwCmdType, optixRtnCascading1j1PGSwDir OPTIXRtn1j1PGSwDirType, optixRtnCascadingPGCfgRowStatus RowStatus } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.110.1.1 optixRtnCascading1j1PGID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the protection group ID." ::= { optixRtnCascading1j1PGParameterEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.110.1.2 optixRtnCascading1j1PGIFBoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the IF board ID." ::= { optixRtnCascading1j1PGParameterEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.110.1.3 optixRtnCascading1j1PGIFSubCardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the IF subboard ID." DEFVAL{ 255 } ::= { optixRtnCascading1j1PGParameterEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.110.1.4 optixRtnCascading1j1PGIFPort OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the IF port ID." DEFVAL{ 1 } ::= { optixRtnCascading1j1PGParameterEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.110.1.5 optixRtnCascading1j1PGRole OBJECT-TYPE SYNTAX OPTIXRtnCascading1j1PGRoleType MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the role of the IF board in the protection group. Values: 0: main board 1: standby board" DEFVAL{ 1 } ::= { optixRtnCascading1j1PGParameterEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.110.1.6 optixRtnCascading1j1PGWorkMode OBJECT-TYPE SYNTAX OPTIXRtn1j1PGWorkModeType MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the work mode. Values: 0: SD 1: FD 2: HSB" DEFVAL{ 2 } ::= { optixRtnCascading1j1PGParameterEntry 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.110.1.7 optixRtnCascading1j1PGRevertiveMode OBJECT-TYPE SYNTAX OPTIXRtnRvtModeType MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the revertive mode. Values: 0: Norvt (non-revertive) 1: Rvt (revertive)" DEFVAL{ 1 } ::= { optixRtnCascading1j1PGParameterEntry 7 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.110.1.8 optixRtnCascading1j1PGWTRTime OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the WTR time. Value range: 300s to 720s" DEFVAL{ 600 } ::= { optixRtnCascading1j1PGParameterEntry 8 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.110.1.9 optixRtnCascading1j1PGRDISwEnableState OBJECT-TYPE SYNTAX OPTIXRtnEnableStateType MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the reverse switching status. Values: 0: disabled 1: enabled" DEFVAL{ 1 } ::= { optixRtnCascading1j1PGParameterEntry 9 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.110.1.10 optixRtnCascading1j1PGProtectType OBJECT-TYPE SYNTAX OPTIXRtnCascading1j1PGProtectType MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the service protection type. 0: noprot (no device-level protection scheme being used) 1: lagprot (LAG protection) 2: splitprot (optical splitter protection) -1: not supported. Has a fixed value of 255 for OptiX RTN 900" ::= { optixRtnCascading1j1PGParameterEntry 10 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.110.1.11 optixRtnCascading1j1PGSlaveMemsInfo OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..16)) MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the information about the cascade members." ::= { optixRtnCascading1j1PGParameterEntry 11 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.110.1.12 optixRtnCascading1j1PGSwCmd OBJECT-TYPE SYNTAX OPTIXRtn1j1PGSwCmdType MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the switching mode of an IF 1+1 protection group." ::= { optixRtnCascading1j1PGParameterEntry 12 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.110.1.13 optixRtnCascading1j1PGSwDir OBJECT-TYPE SYNTAX OPTIXRtn1j1PGSwDirType MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the switching direction of an IF 1+1 protection group." ::= { optixRtnCascading1j1PGParameterEntry 13 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.110.1.50 optixRtnCascadingPGCfgRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the row status." DEFVAL{ active } ::= { optixRtnCascading1j1PGParameterEntry 50 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.120 optixRtnCascading1j1PGStateTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnCascading1j1PGStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Describes parameters about the current status of an cascading IF 1+1 protection group, including the current working board and switching status of the protection group." ::= { optixRtnIFProtect 120 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.120.1 optixRtnCascading1j1PGStateEntry OBJECT-TYPE SYNTAX OptixRtnCascading1j1PGStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the parameter entry for the current status of an cascading IF 1+1 protection group." INDEX{ optixRtnCascading1j1PGID } ::= { optixRtnCascading1j1PGStateTable 1 } OptixRtnCascading1j1PGStateEntry ::= SEQUENCE { optixRtnCascading1j1PGDevWorkNEID Unsigned32, optixRtnCascading1j1PGDevWorkBoardID Unsigned32, optixRtnCascading1j1PGWorkSubCardID Unsigned32, optixRtnCascading1j1PGWorkPortID Unsigned32, optixRtnCascading1j1PGDevWorkBoardState OPTIXRtn1j1PGBDStateType, optixRtnCascading1j1PGDevProtectBoardState OPTIXRtn1j1PGBDStateType, optixRtnCascading1j1PGDevSwtichRequest OPTIXRtn1j1SwtichRequestType, optixRtnCascading1j1PGLinkWorkNEID Unsigned32, optixRtnCascading1j1PGLinkWorkBoardID Unsigned32, optixRtnCascading1j1PGLinkWorkSubCardD Unsigned32, optixRtnCascading1j1PGLinkWorkPortID Unsigned32, optixRtnCascading1j1PGWorkBoardLinkState OPTIXRtn1j1LinkStateType, optixRtnCascading1j1PGProtectBoardLinkState OPTIXRtn1j1LinkStateType, optixRtnCascading1j1PGProtectLinkSwitchRequest OPTIXRtn1j1SwtichRequestType } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.120.1.1 optixRtnCascading1j1PGDevWorkNEID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current working NE ID on the equipment side." ::= { optixRtnCascading1j1PGStateEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.120.1.2 optixRtnCascading1j1PGDevWorkBoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current working board ID on the equipment side." ::= { optixRtnCascading1j1PGStateEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.120.1.3 optixRtnCascading1j1PGWorkSubCardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current working subboard ID on the equipment side." ::= { optixRtnCascading1j1PGStateEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.120.1.4 optixRtnCascading1j1PGWorkPortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current working port ID on the equipment side." ::= { optixRtnCascading1j1PGStateEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.120.1.5 optixRtnCascading1j1PGDevWorkBoardState OBJECT-TYPE SYNTAX OPTIXRtn1j1PGBDStateType MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the working status of the main board on the equipment side. Values: 0: normal 1: switching 2: RDI switching -1: unknown" ::= { optixRtnCascading1j1PGStateEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.120.1.6 optixRtnCascading1j1PGDevProtectBoardState OBJECT-TYPE SYNTAX OPTIXRtn1j1PGBDStateType MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the working status of the standby board on the equipment side. Values: 0: normal 1: switching 2: RDI switching -1: unknown" ::= { optixRtnCascading1j1PGStateEntry 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.120.1.7 optixRtnCascading1j1PGDevSwtichRequest OBJECT-TYPE SYNTAX OPTIXRtn1j1SwtichRequestType MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the switching request on the equipment side. Values: 0: normal 1: automatic 2: manual 3: forced 4: lockout 5: wait to restore 6: RDI" ::= { optixRtnCascading1j1PGStateEntry 7 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.120.1.8 optixRtnCascading1j1PGLinkWorkNEID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current working NE ID on the link side." ::= { optixRtnCascading1j1PGStateEntry 8 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.120.1.9 optixRtnCascading1j1PGLinkWorkBoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current working board ID on the link side." ::= { optixRtnCascading1j1PGStateEntry 9 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.120.1.10 optixRtnCascading1j1PGLinkWorkSubCardD OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current working subboard ID on the link side." ::= { optixRtnCascading1j1PGStateEntry 10 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.120.1.11 optixRtnCascading1j1PGLinkWorkPortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current working port ID on the link side." ::= { optixRtnCascading1j1PGStateEntry 11 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.120.1.12 optixRtnCascading1j1PGWorkBoardLinkState OBJECT-TYPE SYNTAX OPTIXRtn1j1LinkStateType MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the signal status of the main board link. Values: 0: normal 1: signal failure 2: signal deterioration -1: invalid" ::= { optixRtnCascading1j1PGStateEntry 12 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.120.1.13 optixRtnCascading1j1PGProtectBoardLinkState OBJECT-TYPE SYNTAX OPTIXRtn1j1LinkStateType MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the signal status of the stanby board link. Values: 0: normal 1: signal failure 2: signal deterioration -1: invalid" ::= { optixRtnCascading1j1PGStateEntry 13 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.120.1.14 optixRtnCascading1j1PGProtectLinkSwitchRequest OBJECT-TYPE SYNTAX OPTIXRtn1j1SwtichRequestType MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the switching request on the link side. Values: 0: normal 1: automatic 3: forced" ::= { optixRtnCascading1j1PGStateEntry 14 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.130 optixRtnCascadingPhyLagPGParameterTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnCascadingPhyLagPGParameterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Describes configuration parameters for the working board and protection board in a cascading PLA protection group." ::= { optixRtnIFProtect 130 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.130.1 optixRtnCascadingPhyLagPGParameterEntry OBJECT-TYPE SYNTAX OptixRtnCascadingPhyLagPGParameterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the parameter entry for a cascading PLA protection group." INDEX{ optixRtnCascadingPhyLagPGID } ::= { optixRtnCascadingPhyLagPGParameterTable 1 } OptixRtnCascadingPhyLagPGParameterEntry ::= SEQUENCE { optixRtnCascadingPhyLagPGID Unsigned32, optixRtnCascadingPhyLagPGMainBoardID Unsigned32, optixRtnCascadingPhyLagPGMainSubCardID Unsigned32, optixRtnCascadingPhyLagPGMainPortID Unsigned32, optixRtnCascadingPhyLagPGRole OPTIXRtnCascadingPLAPGRoleType, optixRtnCascadingPhyLagPGProtectType OPTIXRtnCascadingPhyLagPGProtectType, optixRtnCascadingPhyLagPGCascadingPuNum Unsigned32, optixRtnCascadingPhyLagPGPu1BoardID Unsigned32, optixRtnCascadingPhyLagPGPu1SubCardID Unsigned32, optixRtnCascadingPhyLagPGPu1PortID Unsigned32, optixRtnCascadingPhyLagPGPortNum Unsigned32, optixRtnCascadingPhyLagPGCascadingConMemsInfo OCTET STRING, optixRtnCascadingPhyLagPGCfgRowStatus RowStatus } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.130.1.1 optixRtnCascadingPhyLagPGID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicats the protection group ID." ::= { optixRtnCascadingPhyLagPGParameterEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.130.1.2 optixRtnCascadingPhyLagPGMainBoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the slot ID of the main unit." ::= { optixRtnCascadingPhyLagPGParameterEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.130.1.3 optixRtnCascadingPhyLagPGMainSubCardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the subboard ID of the main unit." ::= { optixRtnCascadingPhyLagPGParameterEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.130.1.4 optixRtnCascadingPhyLagPGMainPortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the port ID of the main unit." ::= { optixRtnCascadingPhyLagPGParameterEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.130.1.5 optixRtnCascadingPhyLagPGRole OBJECT-TYPE SYNTAX OPTIXRtnCascadingPLAPGRoleType MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the role of the current NE in the PLA protection group. Values: 0: slave NE 1: main NE" ::= { optixRtnCascadingPhyLagPGParameterEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.130.1.6 optixRtnCascadingPhyLagPGProtectType OBJECT-TYPE SYNTAX OPTIXRtnCascadingPhyLagPGProtectType MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the PLA protection group type. Values: 0: noprot (does not support equipment-level protection) 1: prot (support equipment-level protection) This parameter indicates whether the standby equipment is available when a fault occurs. The current equipment can only take the -1 value." ::= { optixRtnCascadingPhyLagPGParameterEntry 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.130.1.7 optixRtnCascadingPhyLagPGCascadingPuNum OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the number of cascading ports. Value range: 1 to 3" DEFVAL{ 1 } ::= { optixRtnCascadingPhyLagPGParameterEntry 7 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.130.1.8 optixRtnCascadingPhyLagPGPu1BoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the board ID of the cascading unit 1." ::= { optixRtnCascadingPhyLagPGParameterEntry 8 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.130.1.9 optixRtnCascadingPhyLagPGPu1SubCardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the subboard ID of the cascading unit 1." ::= { optixRtnCascadingPhyLagPGParameterEntry 9 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.130.1.10 optixRtnCascadingPhyLagPGPu1PortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the port ID of the cascading unit 1." ::= { optixRtnCascadingPhyLagPGParameterEntry 10 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.130.1.11 optixRtnCascadingPhyLagPGPortNum OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the service port ID and has a fixed value of 0 for OptiX RTN 900." ::= { optixRtnCascadingPhyLagPGParameterEntry 11 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.130.1.12 optixRtnCascadingPhyLagPGCascadingConMemsInfo OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates cascading port information of a PLA group consisting of cascading NEs." ::= { optixRtnCascadingPhyLagPGParameterEntry 12 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.130.1.50 optixRtnCascadingPhyLagPGCfgRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the row status of a protection group" DEFVAL{ active } ::= { optixRtnCascadingPhyLagPGParameterEntry 50 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.140 optixRtnCascadingPhyLagPGStateTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnCascadingPhyLagPGStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Describes parameters about the status of a cascading PLA protection group, including the current working board and the switching status of a protection group." ::= { optixRtnIFProtect 140 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.140.1 optixRtnCascadingPhyLagPGStateEntry OBJECT-TYPE SYNTAX OptixRtnCascadingPhyLagPGStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the status parameter entry for a cascading PLA protection group." INDEX{ optixRtnCascadingPhyLagPGID } ::= { optixRtnCascadingPhyLagPGStateTable 1 } OptixRtnCascadingPhyLagPGStateEntry ::= SEQUENCE { optixRtnCascadingPhyLagPGStateMainNEID Unsigned32, optixRtnCascadingPhyLagPGStateMainBoardID Unsigned32, optixRtnCascadingPhyLagPGStateMainSubID Unsigned32, optixRtnCascadingPhyLagPGStateMainPortID Unsigned32, optixRtnCascadingPhyLagPGMainHardStatus OPTIXRtnPhyLagPGStatus, optixRtnCascadingPhyLagPGMainLinkStatus OPTIXRtnPhyLagPGStatus, optixRtnCascadingPhyLagPGMainMSStatus OPTIXRtnCascadingPLAPGRoleType, optixRtnCascadingPhyLagPGSlavePuNum Unsigned32, optixRtnCascadingPhyLagPGStatePu1NEID Unsigned32, optixRtnCascadingPhyLagPGStatePu1BoardID Unsigned32, optixRtnCascadingPhyLagPGStatePu1SubCardID Unsigned32, optixRtnCascadingPhyLagPGStatePu1PortID Unsigned32, optixRtnCascadingPhyLagPGStatePu1HardStatus OPTIXRtnPhyLagPGStatus, optixRtnCascadingPhyLagPGStatePu1LinkStatus OPTIXRtnPhyLagPGStatus, optixRtnCascadingPhyLagPGStatePu1MSStatus OPTIXRtnPhyLagPGStateWorkStatus } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.140.1.1 optixRtnCascadingPhyLagPGStateMainNEID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the main NE ID." ::= { optixRtnCascadingPhyLagPGStateEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.140.1.2 optixRtnCascadingPhyLagPGStateMainBoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slot ID of the main unit." ::= { optixRtnCascadingPhyLagPGStateEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.140.1.3 optixRtnCascadingPhyLagPGStateMainSubID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the subboard ID of the main unit." ::= { optixRtnCascadingPhyLagPGStateEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.140.1.4 optixRtnCascadingPhyLagPGStateMainPortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the port ID of the main unit." ::= { optixRtnCascadingPhyLagPGStateEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.140.1.5 optixRtnCascadingPhyLagPGMainHardStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the hardware status of the main unit. Values: 0: normal 1: abnormal -1: unknown" ::= { optixRtnCascadingPhyLagPGStateEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.140.1.6 optixRtnCascadingPhyLagPGMainLinkStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the link status of the main unit. Values: 0: normal 1: abnormal -1: unknown" ::= { optixRtnCascadingPhyLagPGStateEntry 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.140.1.7 optixRtnCascadingPhyLagPGMainMSStatus OBJECT-TYPE SYNTAX OPTIXRtnCascadingPLAPGRoleType MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the working status of the main unit. Values: 0: slave port 1: main port" ::= { optixRtnCascadingPhyLagPGStateEntry 7 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.140.1.8 optixRtnCascadingPhyLagPGSlavePuNum OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the number of cascading units. Value range: 1 to 3" ::= { optixRtnCascadingPhyLagPGStateEntry 8 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.140.1.9 optixRtnCascadingPhyLagPGStatePu1NEID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the NE ID of the cascading unit 1." ::= { optixRtnCascadingPhyLagPGStateEntry 9 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.140.1.10 optixRtnCascadingPhyLagPGStatePu1BoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the board ID of the cascading unit 1. An invalid value of 65535 is returned when the adjacency channel is faulty." ::= { optixRtnCascadingPhyLagPGStateEntry 10 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.140.1.11 optixRtnCascadingPhyLagPGStatePu1SubCardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the subboard ID of the cascading unit 1. An invalid value of 255 is returned when the adjacency channel is faulty." ::= { optixRtnCascadingPhyLagPGStateEntry 11 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.140.1.12 optixRtnCascadingPhyLagPGStatePu1PortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the port ID of the cascading unit 1. An invalid value of 255 is returned when the adjacency channel is faulty." ::= { optixRtnCascadingPhyLagPGStateEntry 12 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.140.1.13 optixRtnCascadingPhyLagPGStatePu1HardStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the hardware status of the cascading unit 1. Values: 0: normal 1: abnormal -1: unknown" ::= { optixRtnCascadingPhyLagPGStateEntry 13 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.140.1.14 optixRtnCascadingPhyLagPGStatePu1LinkStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the link status of the cascading unit 1. Values: 0: normal 1: abnormal -1: unknown" ::= { optixRtnCascadingPhyLagPGStateEntry 14 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.140.1.15 optixRtnCascadingPhyLagPGStatePu1MSStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStateWorkStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the working status of the cascading unit 1. Values: 0: slave port 1: main port" ::= { optixRtnCascadingPhyLagPGStateEntry 15 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.150 optixRtnCascadingPhyLagPGParameterExtTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnCascadingPhyLagPGParameterExtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Describes configuration parameters for the working board and protection board in a cascading PLA/EPLA protection group." ::= { optixRtnIFProtect 150 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.150.1 optixRtnCascadingPhyLagPGParameterExtEntry OBJECT-TYPE SYNTAX OptixRtnCascadingPhyLagPGParameterExtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the parameter entry for a cascading PLA/EPLA protection group." INDEX{ optixRtnCascadingPhyLagPGID } ::= { optixRtnCascadingPhyLagPGParameterExtTable 1 } OptixRtnCascadingPhyLagPGParameterExtEntry ::= SEQUENCE { optixRtnCascadingPhyLagPGTypeExt OPTIXRtnPhyLagPGType, optixRtnCascadingPhyLagPGMainSlotIDExt Unsigned32, optixRtnCascadingPhyLagPGMainSubCardIDExt Unsigned32, optixRtnCascadingPhyLagPGMainPortIDExt Unsigned32, optixRtnPhyLagPGSlaveMemsInfoExt OCTET STRING, optixRtnCascadingPhyLagPGRoleExt OPTIXRtnCascadingPLAPGRoleType, optixRtnCascadingPhyLagPGProtectTypeExt OPTIXRtnCascadingPhyLagPGProtectTypeExt, optixRtnCascadingPhyLagLcConMemsInfo OCTET STRING, optixRtnCascadingPhyLagNbConMemsInfo OCTET STRING, optixRtnCascadingPhyLagPGLinkThresholdExt Unsigned32, optixRtnCascadingPhyLagPGServicePortInfo OCTET STRING, optixRtnCascadingPhyLagPGCfgRowStatusExt RowStatus } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.150.1.1 optixRtnCascadingPhyLagPGTypeExt OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGType MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the protection group type. Values: 0: PLA 1: EPLA 2: cascading PLA 3:cascading EPLA" ::= { optixRtnCascadingPhyLagPGParameterExtEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.150.1.2 optixRtnCascadingPhyLagPGMainSlotIDExt OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the slot ID of the main port." ::= { optixRtnCascadingPhyLagPGParameterExtEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.150.1.3 optixRtnCascadingPhyLagPGMainSubCardIDExt OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the subboard ID of the main port." ::= { optixRtnCascadingPhyLagPGParameterExtEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.150.1.4 optixRtnCascadingPhyLagPGMainPortIDExt OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the port number of the main port." ::= { optixRtnCascadingPhyLagPGParameterExtEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.150.1.5 optixRtnPhyLagPGSlaveMemsInfoExt OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the slave port information of the protection group." ::= { optixRtnCascadingPhyLagPGParameterExtEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.150.1.6 optixRtnCascadingPhyLagPGRoleExt OBJECT-TYPE SYNTAX OPTIXRtnCascadingPLAPGRoleType MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the role of the current NE in the protection group. Values: 0: slave NE 1: master NE" ::= { optixRtnCascadingPhyLagPGParameterExtEntry 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.150.1.7 optixRtnCascadingPhyLagPGProtectTypeExt OBJECT-TYPE SYNTAX OPTIXRtnCascadingPhyLagPGProtectTypeExt MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the protection group type. Values: 0: no protection 1: LAG protection 2: optical splitter protection" ::= { optixRtnCascadingPhyLagPGParameterExtEntry 7 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.150.1.8 optixRtnCascadingPhyLagLcConMemsInfo OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the local NE information of the protection group." ::= { optixRtnCascadingPhyLagPGParameterExtEntry 8 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.150.1.9 optixRtnCascadingPhyLagNbConMemsInfo OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the neighbor NE information of the protection group." ::= { optixRtnCascadingPhyLagPGParameterExtEntry 9 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.150.1.10 optixRtnCascadingPhyLagPGLinkThresholdExt OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the minimum number of active links in the protection group." ::= { optixRtnCascadingPhyLagPGParameterExtEntry 10 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.150.1.11 optixRtnCascadingPhyLagPGServicePortInfo OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-create STATUS deprecated DESCRIPTION "Indicates service port information of a PLA group consisting of cascading NEs." ::= { optixRtnCascadingPhyLagPGParameterExtEntry 11 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.150.1.50 optixRtnCascadingPhyLagPGCfgRowStatusExt OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the row status of the protection group." DEFVAL{ active } ::= { optixRtnCascadingPhyLagPGParameterExtEntry 50 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.160 optixRtnCascadingPhyLagPGStateExtTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnCascadingPhyLagPGStateExtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Describes status parameters for the protection group." ::= { optixRtnIFProtect 160 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.160.1 optixRtnCascadingPhyLagPGStateExtEntry OBJECT-TYPE SYNTAX OptixRtnCascadingPhyLagPGStateExtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the status parameter entry for the protection group." INDEX{ optixRtnCascadingPhyLagPGID,optixRtnCascadingPhyLagPGStateMSNEID,optixRtnCascadingPhyLagPGStateMSSlotID,optixRtnCascadingPhyLagPGStateMSSubCardID,optixRtnCascadingPhyLagPGStateMSPortID } ::= { optixRtnCascadingPhyLagPGStateExtTable 1 } OptixRtnCascadingPhyLagPGStateExtEntry ::= SEQUENCE { optixRtnCascadingPhyLagPGStateMSNEID Unsigned32, optixRtnCascadingPhyLagPGStateMSSlotID Unsigned32, optixRtnCascadingPhyLagPGStateMSSubCardID Unsigned32, optixRtnCascadingPhyLagPGStateMSPortID Unsigned32, optixRtnCascadingPhyLagPGStateMSHardStatus OPTIXRtnPhyLagPGStatus, optixRtnCascadingPhyLagPGStateMSLinkStatus OPTIXRtnPhyLagPGStatus, optixRtnCascadingPhyLagPGStateMSStatusExt OPTIXRtnCascadingPLAPGRoleType } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.160.1.1 optixRtnCascadingPhyLagPGStateMSNEID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the NE ID of the protection group." ::= { optixRtnCascadingPhyLagPGStateExtEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.160.1.2 optixRtnCascadingPhyLagPGStateMSSlotID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the slot ID of the protection group." ::= { optixRtnCascadingPhyLagPGStateExtEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.160.1.3 optixRtnCascadingPhyLagPGStateMSSubCardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the subboard ID of the protection group." ::= { optixRtnCascadingPhyLagPGStateExtEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.160.1.4 optixRtnCascadingPhyLagPGStateMSPortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the port number of the protection group." ::= { optixRtnCascadingPhyLagPGStateExtEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.160.1.5 optixRtnCascadingPhyLagPGStateMSHardStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the hardware status of the member port in the protection group. Values: 0: normal 1: abnormal -1: unknown" ::= { optixRtnCascadingPhyLagPGStateExtEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.160.1.6 optixRtnCascadingPhyLagPGStateMSLinkStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the link status of the member port in the protection group. Values: 0: normal 1: abnormal -1: unknown" ::= { optixRtnCascadingPhyLagPGStateExtEntry 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.160.1.7 optixRtnCascadingPhyLagPGStateMSStatusExt OBJECT-TYPE SYNTAX OPTIXRtnCascadingPLAPGRoleType MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the working status of the member port in the protection group. Values: 0: slave port 1: main port" ::= { optixRtnCascadingPhyLagPGStateExtEntry 7 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.180 optixRtnFO1j1PGStateTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnFO1j1PGStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Describes parameters about the current status of an FO IF 1+1 protection group, including the current working board and switching status of the protection group." ::= { optixRtnIFProtect 180 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.180.1 optixRtnFO1j1PGStateEntry OBJECT-TYPE SYNTAX OptixRtnFO1j1PGStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the parameter entry for the current status of an FO IF 1+1 protection group." INDEX{ optixRtnCascading1j1PGrID } ::= { optixRtnFO1j1PGStateTable 1 } OptixRtnFO1j1PGStateEntry ::= SEQUENCE { optixRtnFO1j1PGDevWorkNEID Unsigned32, optixRtnFO1j1PGDevWorkBoardID Unsigned32, optixRtnFO1j1PGWorkSubCardID Unsigned32, optixRtnFO1j1PGWorkPortID Unsigned32, optixRtnFO1j1PGDevWorkBoardState OPTIXRtn1j1PGBDStateType, optixRtnFO1j1PGDevProtectBoardState OPTIXRtn1j1PGBDStateType, optixRtnFO1j1PGDevSwtichRequest OPTIXRtn1j1SwtichRequestType, optixRtnFO1j1PGLinkWorkNEID Unsigned32, optixRtnFO1j1PGLinkWorkBoardID Unsigned32, optixRtnFO1j1PGLinkWorkSubCardID Unsigned32, optixRtnFO1j1PGLinkWorkPortID Unsigned32, optixRtnFO1j1PGWorkBoardLinkState OPTIXRtn1j1LinkStateType, optixRtnFO1j1PGProtectBoardLinkState OPTIXRtn1j1LinkStateType, optixRtnFO1j1PGProtectLinkSwitchRequest OPTIXRtn1j1SwtichRequestType } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.180.1.1 optixRtnFO1j1PGDevWorkNEID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current working NE ID on the equipment side." ::= { optixRtnFO1j1PGStateEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.180.1.2 optixRtnFO1j1PGDevWorkBoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current working board ID on the equipment side." ::= { optixRtnFO1j1PGStateEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.180.1.3 optixRtnFO1j1PGWorkSubCardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current working subboard ID on the equipment side." ::= { optixRtnFO1j1PGStateEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.180.1.4 optixRtnFO1j1PGWorkPortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current working port ID on the equipment side." ::= { optixRtnFO1j1PGStateEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.180.1.5 optixRtnFO1j1PGDevWorkBoardState OBJECT-TYPE SYNTAX OPTIXRtn1j1PGBDStateType MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the working status of the main board on the equipment side. Values: 0: normal 1: switching 2: RDI switching 255: unknown" ::= { optixRtnFO1j1PGStateEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.180.1.6 optixRtnFO1j1PGDevProtectBoardState OBJECT-TYPE SYNTAX OPTIXRtn1j1PGBDStateType MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the working status of the standby board on the equipment side. Values: 0: normal 1: switching 2: RDI switching 255: unknown" ::= { optixRtnFO1j1PGStateEntry 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.180.1.7 optixRtnFO1j1PGDevSwtichRequest OBJECT-TYPE SYNTAX OPTIXRtn1j1SwtichRequestType MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the switching request on the equipment side. Values: 0: normal 1: automatic 2: manual 3: forced 4: lockout 5: wait to restore 6: RDI" ::= { optixRtnFO1j1PGStateEntry 7 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.180.1.8 optixRtnFO1j1PGLinkWorkNEID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current working NE ID on the link side." ::= { optixRtnFO1j1PGStateEntry 8 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.180.1.9 optixRtnFO1j1PGLinkWorkBoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current working board ID on the link side." ::= { optixRtnFO1j1PGStateEntry 9 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.180.1.10 optixRtnFO1j1PGLinkWorkSubCardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current working subboard ID on the link side." ::= { optixRtnFO1j1PGStateEntry 10 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.180.1.11 optixRtnFO1j1PGLinkWorkPortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current working port ID on the link side." ::= { optixRtnFO1j1PGStateEntry 11 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.180.1.12 optixRtnFO1j1PGWorkBoardLinkState OBJECT-TYPE SYNTAX OPTIXRtn1j1LinkStateType MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the signal status of the main board link. Values: 0: normal 1: signal failure 2: signal deterioration 255: invalid" ::= { optixRtnFO1j1PGStateEntry 12 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.180.1.13 optixRtnFO1j1PGProtectBoardLinkState OBJECT-TYPE SYNTAX OPTIXRtn1j1LinkStateType MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the signal status of the stanby board link. Values: 0: normal 1: signal failure 2: signal deterioration 255: invalid" ::= { optixRtnFO1j1PGStateEntry 13 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.180.1.14 optixRtnFO1j1PGProtectLinkSwitchRequest OBJECT-TYPE SYNTAX OPTIXRtn1j1SwtichRequestType MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the switching request on the link side. Values: 0: normal 1: automatic 3: forced" ::= { optixRtnFO1j1PGStateEntry 14 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.190 optixRtnCascading1j1PGParameterExTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnCascading1j1PGParameterExEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Describes parameters about an FO IF 1+1 protection group, including the IF board used in the protection group and the role of the IF board in the protection group." ::= { optixRtnIFProtect 190 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.190.1 optixRtnCascading1j1PGParameterExEntry OBJECT-TYPE SYNTAX OptixRtnCascading1j1PGParameterExEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the parameter entry for an FO IF 1+1 protection group." INDEX{ optixRtnCascading1j1PGrID } ::= { optixRtnCascading1j1PGParameterExTable 1 } OptixRtnCascading1j1PGParameterExEntry ::= SEQUENCE { optixRtnCascading1j1PGrID Unsigned32, optixRtnCascading1j1PGrRevertiveMode OPTIXRtnRvtModeType, optixRtnCascading1j1PGrWTRTime Unsigned32, optixRtnCascading1j1PGrBID Unsigned32, optixRtnCascading1j1PGrCasPortID Unsigned32 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.190.1.1 optixRtnCascading1j1PGrID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the protection group ID." ::= { optixRtnCascading1j1PGParameterExEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.190.1.2 optixRtnCascading1j1PGrRevertiveMode OBJECT-TYPE SYNTAX OPTIXRtnRvtModeType MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the reversion mode. Values: 0: norvt (non-revertive) 1: rvt (revertive)" ::= { optixRtnCascading1j1PGParameterExEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.190.1.3 optixRtnCascading1j1PGrWTRTime OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the WTR time. Value range: 300s to 720s" DEFVAL{ 600 } ::= { optixRtnCascading1j1PGParameterExEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.190.1.4 optixRtnCascading1j1PGrBID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the board ID(this node is used only on RTN300 devices)." ::= { optixRtnCascading1j1PGParameterExEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.190.1.5 optixRtnCascading1j1PGrCasPortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the cascade port ID(this node is used only on RTN300 devices). Value range: 2 to 5" DEFVAL{ 3 } ::= { optixRtnCascading1j1PGParameterExEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.200 optixRtnINHPGAlmTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnINHPGAlmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the configuration parameters related to the alarm inhibition of the protection group." ::= { optixRtnIFProtect 200 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.200.1 optixRtnINHPGAlmEntry OBJECT-TYPE SYNTAX OptixRtnINHPGAlmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the configuration parameter entry related to the alarm inhibition of the protection group." INDEX{ optixRtnINHPgType,optixRtnINHPgID,optixRtnINHPgAlmEvent } ::= { optixRtnINHPGAlmTable 1 } OptixRtnINHPGAlmEntry ::= SEQUENCE { optixRtnINHPgType OPTIXRtnPgType, optixRtnINHPgID Unsigned32, optixRtnINHPgAlmEvent AlarmINHPG1J1EventType, optixRtnINHPgAlmStatus OPTIXRtnEnableStateType } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.200.1.1 optixRtnINHPgType OBJECT-TYPE SYNTAX OPTIXRtnPgType MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the type of the protection group. Value range: 1 indicates IF 1+1 protection. 2 indicates cascading 1+1 protection." ::= { optixRtnINHPGAlmEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.200.1.2 optixRtnINHPgID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the ID of the protection group." ::= { optixRtnINHPGAlmEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.200.1.3 optixRtnINHPgAlmEvent OBJECT-TYPE SYNTAX AlarmINHPG1J1EventType MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the ID of the inhibited alarm." ::= { optixRtnINHPGAlmEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.200.1.4 optixRtnINHPgAlmStatus OBJECT-TYPE SYNTAX OPTIXRtnEnableStateType MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the enable status of the alarm inhibition. Value range: 0 indicates disabled and 1 indicates enabled." ::= { optixRtnINHPGAlmEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.210 optixRtnNbplaStateTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnNbplaStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "It is applicable to the cascade PLA/EPLA management table." ::= { optixRtnIFProtect 210 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.210.1 optixRtnNbplaStateEntry OBJECT-TYPE SYNTAX OptixRtnNbplaStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "It is applicable to the cascade PLA management table and the cascade EPLA management table (containing only two members)." INDEX{ optixRtnCascadingPhyLagPGID } ::= { optixRtnNbplaStateTable 1 } OptixRtnNbplaStateEntry ::= SEQUENCE { optixRtnPLANEId Unsigned32, optixRtnPLAMSBID Unsigned32, optixRtnPLAMSSUBID Unsigned32, optixRtnPLAMSPID INTEGER, optixRtnPLAHardState INTEGER, optixRtnPLALinkState INTEGER, optixRtnPLAMSState INTEGER } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.210.1.1 optixRtnPLANEId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the ID of the working NE." ::= { optixRtnNbplaStateEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.210.1.2 optixRtnPLAMSBID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the ID of the active port on the working NE." ::= { optixRtnNbplaStateEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.210.1.3 optixRtnPLAMSSUBID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the subboard ID of the active port on the working NE." ::= { optixRtnNbplaStateEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.210.1.4 optixRtnPLAMSPID OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the active port number of the working NE." ::= { optixRtnNbplaStateEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.210.1.5 optixRtnPLAHardState OBJECT-TYPE SYNTAX INTEGER { normal(0), abnormal(1), unknown(255), unknownState(-1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the hardware status of the active port on the working NE." ::= { optixRtnNbplaStateEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.210.1.6 optixRtnPLALinkState OBJECT-TYPE SYNTAX INTEGER { normal(0), abnormal(1), unknown(255), unknownState(-1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the link status of the active port on the working NE." ::= { optixRtnNbplaStateEntry 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.210.1.7 optixRtnPLAMSState OBJECT-TYPE SYNTAX INTEGER { slave(0), master(1), unknown(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current status (active/standby) of the active port on the working NE." ::= { optixRtnNbplaStateEntry 7 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.221 optixRtnCascading1j1PGAlmNewTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnCascading1j1PGAlmNewEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Describes parameters about a cascading IF 1+1 protection group, including the IF board used in the protection group and the role of the IF board in the protection group." ::= { optixRtnIFProtect 221 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.221.1 optixRtnCascading1j1PGAlmNewEntry OBJECT-TYPE SYNTAX OptixRtnCascading1j1PGAlmNewEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the parameter entry for a cascading IF 1+1 protection group." INDEX{ optixRtnCascading1j1PGID } ::= { optixRtnCascading1j1PGAlmNewTable 1 } OptixRtnCascading1j1PGAlmNewEntry ::= SEQUENCE { optixRtnCascading1j1PGsrvalmNew Unsigned32, optixRtnCascading1j1PGalmmomNew Unsigned32 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.221.1.1 optixRtnCascading1j1PGsrvalmNew OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the protection group srvalm." ::= { optixRtnCascading1j1PGAlmNewEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.221.1.2 optixRtnCascading1j1PGalmmomNew OBJECT-TYPE SYNTAX Unsigned32 { reportIfBdAlm(1), report1J1PgAlm(2), reportIfBdAnd1J1PgAlm(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the IF board almmom." ::= { optixRtnCascading1j1PGAlmNewEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.230 optixRtnNonCascade1j1StateParameterTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnNonCascade1j1StateParameterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Describes parameters about an FO IF 1+1 protection group, including the IF board used in the protection group and the role of the IF board in the protection group." ::= { optixRtnIFProtect 230 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.230.1 optixRtnNonCascade1j1StateParameterEntry OBJECT-TYPE SYNTAX OptixRtnNonCascade1j1StateParameterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the parameter entry for an FO IF 1+1 protection group." INDEX{ optixRtnCascading1j1PGrID } ::= { optixRtnNonCascade1j1StateParameterTable 1 } OptixRtnNonCascade1j1StateParameterEntry ::= SEQUENCE { optixRtnNonCascade1j1DevWorkBoardID Unsigned32, optixRtnNonCascade1j1DevWorkSubCardID Unsigned32, optixRtnNonCascade1j1DevWorkPortID Unsigned32, optixRtnNonCascade1j1DevWorkBoardState OPTIXRtn1j1PGBDStateType, optixRtnNonCascade1j1DevProtectBoardState OPTIXRtn1j1PGBDStateType, optixRtnNonCascade1j1DevSwtichRequest OPTIXRtn1j1SwtichRequestType, optixRtnNonCascade1j1LinkWorkBoardID Unsigned32, optixRtnNonCascade1j1LinkWorkSubCardID Unsigned32, optixRtnNonCascade1j1LinkWorkPortID Unsigned32, optixRtnNonCascade1j1WorkBoardLinkState OPTIXRtn1j1LinkStateType, optixRtnNonCascade1j1ProtectBoardLinkState OPTIXRtn1j1LinkStateType, optixRtnNonCascade1j1ProtectLinkSwitchRequest OPTIXRtn1j1SwtichRequestType, optixRtnNonCascade1j1RDIEnState INTEGER, optixRtnNonCascade1j1PGSwCmd INTEGER, optixRtnNonCascade1j1PGSwDir INTEGER } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.230.1.1 optixRtnNonCascade1j1DevWorkBoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current working board ID on the equipment side." ::= { optixRtnNonCascade1j1StateParameterEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.230.1.2 optixRtnNonCascade1j1DevWorkSubCardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current working subboard ID on the equipment side." ::= { optixRtnNonCascade1j1StateParameterEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.230.1.3 optixRtnNonCascade1j1DevWorkPortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current working port ID on the equipment side." ::= { optixRtnNonCascade1j1StateParameterEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.230.1.4 optixRtnNonCascade1j1DevWorkBoardState OBJECT-TYPE SYNTAX OPTIXRtn1j1PGBDStateType MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the working status of the main board on the equipment side. Values: 0: normal 1: switching 2: RDI switching 255: unknown" ::= { optixRtnNonCascade1j1StateParameterEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.230.1.5 optixRtnNonCascade1j1DevProtectBoardState OBJECT-TYPE SYNTAX OPTIXRtn1j1PGBDStateType MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the working status of the standby board on the equipment side. Values: 0: normal 1: switching 2: RDI switching 255: unknown" ::= { optixRtnNonCascade1j1StateParameterEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.230.1.6 optixRtnNonCascade1j1DevSwtichRequest OBJECT-TYPE SYNTAX OPTIXRtn1j1SwtichRequestType MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the switching request on the equipment side. Values: 0: normal 1: automatic 2: manual 3: forced 4: lockout 5: wait to restore 6: RDI" ::= { optixRtnNonCascade1j1StateParameterEntry 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.230.1.7 optixRtnNonCascade1j1LinkWorkBoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current working board ID on the link side." ::= { optixRtnNonCascade1j1StateParameterEntry 7 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.230.1.8 optixRtnNonCascade1j1LinkWorkSubCardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current working subboard ID on the link side." ::= { optixRtnNonCascade1j1StateParameterEntry 8 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.230.1.9 optixRtnNonCascade1j1LinkWorkPortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current working port ID on the link side." ::= { optixRtnNonCascade1j1StateParameterEntry 9 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.230.1.10 optixRtnNonCascade1j1WorkBoardLinkState OBJECT-TYPE SYNTAX OPTIXRtn1j1LinkStateType MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the signal status of the main board link. Values: 0: normal 1: signal failure 2: signal deterioration 255: invalid" ::= { optixRtnNonCascade1j1StateParameterEntry 10 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.230.1.11 optixRtnNonCascade1j1ProtectBoardLinkState OBJECT-TYPE SYNTAX OPTIXRtn1j1LinkStateType MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the signal status of the stanby board link. Values: 0: normal 1: signal failure 2: signal deterioration 255: invalid" ::= { optixRtnNonCascade1j1StateParameterEntry 11 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.230.1.12 optixRtnNonCascade1j1ProtectLinkSwitchRequest OBJECT-TYPE SYNTAX OPTIXRtn1j1SwtichRequestType MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the switching request on the link side. Values: 0: normal 1: automatic 3: forced" ::= { optixRtnNonCascade1j1StateParameterEntry 12 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.230.1.13 optixRtnNonCascade1j1RDIEnState OBJECT-TYPE SYNTAX INTEGER { disable(0), enbale(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the state of RDI" DEFVAL{ 1 } ::= { optixRtnNonCascade1j1StateParameterEntry 13 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.230.1.14 optixRtnNonCascade1j1PGSwCmd OBJECT-TYPE SYNTAX INTEGER { manual(0), force(1), lockout(2), clear(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the switch mode" DEFVAL{ 255 } ::= { optixRtnNonCascade1j1StateParameterEntry 14 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.230.1.15 optixRtnNonCascade1j1PGSwDir OBJECT-TYPE SYNTAX INTEGER { w2p(0), p2w(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the switch direction" DEFVAL{ 1 } ::= { optixRtnNonCascade1j1StateParameterEntry 15 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.237 optixRtnCfgEplaThroughAttrTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnCfgEplaThroughAttrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { optixRtnIFProtect 237 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.237.1 optixRtnCfgEplaThroughAttrEntry OBJECT-TYPE SYNTAX OptixRtnCfgEplaThroughAttrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX{ optixRtngroupIndex,optixRtnboardIndex,optixRtnsubboardIndex,optixRtnportIndex} ::= { optixRtnCfgEplaThroughAttrTable 1 } OptixRtnCfgEplaThroughAttrEntry ::= SEQUENCE { optixRtnCfgEplaThroughAttrDeviceType Unsigned32, optixRtnCfgEplaThroughAttrBandWidth Unsigned32, optixRtnCfgEplaThroughAttrVlanId Unsigned32, optixRtnCfgEplaThroughAttrMainboardID Unsigned32, optixRtnCfgEplaThroughAttrMianSubboardID Unsigned32, optixRtnCfgEplaThroughAttrMianPortID Unsigned32 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.237.1.5 optixRtnCfgEplaThroughAttrDeviceType OBJECT-TYPE SYNTAX Unsigned32 { huawei(0), third-Party(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "device type" ::= { optixRtnCfgEplaThroughAttrEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.237.1.6 optixRtnCfgEplaThroughAttrBandWidth OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "band width" ::= { optixRtnCfgEplaThroughAttrEntry 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.237.1.7 optixRtnCfgEplaThroughAttrVlanId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "vlanid" ::= { optixRtnCfgEplaThroughAttrEntry 7 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.237.1.8 optixRtnCfgEplaThroughAttrMainboardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "epla mian boardid" ::= { optixRtnCfgEplaThroughAttrEntry 8 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.237.1.9 optixRtnCfgEplaThroughAttrMianSubboardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "epla mian subboardid" ::= { optixRtnCfgEplaThroughAttrEntry 9 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.237.1.10 optixRtnCfgEplaThroughAttrMianPortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "epla mian portid" ::= { optixRtnCfgEplaThroughAttrEntry 10 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.238 optixRtnCCEnableTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnCCEnableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Describes the state of the CC enable parameter in an EPLA protection group ." ::= { optixRtnIFProtect 238 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.238.1 optixRtnCCEnableEntry OBJECT-TYPE SYNTAX OptixRtnCCEnableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the entry for enabling CC for an EPLA protection group." INDEX{ optixRtnCCEnablePGID,optixRtnCCEnablePGType } ::= { optixRtnCCEnableTable 1 } OptixRtnCCEnableEntry ::= SEQUENCE { optixRtnCCEnablePGID Unsigned32, optixRtnCCEnablePGType OPTIXRtnPhyLagPGType, optixRtnCCEnable INTEGER } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.238.1.1 optixRtnCCEnablePGID OBJECT-TYPE SYNTAX Unsigned32 (1..12) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the ID of an EPLA protection group." ::= { optixRtnCCEnableEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.238.1.2 optixRtnCCEnablePGType OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGType MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the protection group type. Values: 0: pla 1: epla 2: nbpla 3: nbepla 4: eplaplus" ::= { optixRtnCCEnableEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.238.1.3 optixRtnCCEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the state of the CC enable parameter in an EPLA protection group." DEFVAL{ 0 } ::= { optixRtnCCEnableEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.240 optixRtnNonCascadePLAParameterTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnNonCascadePLAParameterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Describes configuration parameters for the working board and protection board in a cascading PLA/EPLA protection group." ::= { optixRtnIFProtect 240 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.240.1 optixRtnNonCascadePLAParameterEntry OBJECT-TYPE SYNTAX OptixRtnNonCascadePLAParameterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the parameter entry for a cascading PLA/EPLA protection group." INDEX{ optixRtnPhyLagPGID } ::= { optixRtnNonCascadePLAParameterTable 1 } OptixRtnNonCascadePLAParameterEntry ::= SEQUENCE { optixRtnNonCascadePLAPGType OPTIXRtnPhyLagPGType, optixRtnNonCascadePLAPGMainSlotID Unsigned32, optixRtnNonCascadePLAPGMainSubCardID Unsigned32, optixRtnNonCascadePLAPGMainPortID Unsigned32, optixRtnNonCascadePLAPGSlaveMemsInfo OCTET STRING, optixRtnNonCascadePLAPGLinkThreshold Unsigned32, optixRtnNonCascadePLAPGRowStatus RowStatus } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.240.1.1 optixRtnNonCascadePLAPGType OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGType MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the protection group type. Values: 0: PLA 1: EPLA 2: cascading PLA 3:cascading EPLA" ::= { optixRtnNonCascadePLAParameterEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.240.1.2 optixRtnNonCascadePLAPGMainSlotID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the slot ID of the main port." ::= { optixRtnNonCascadePLAParameterEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.240.1.3 optixRtnNonCascadePLAPGMainSubCardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the subboard ID of the main port." ::= { optixRtnNonCascadePLAParameterEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.240.1.4 optixRtnNonCascadePLAPGMainPortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the port number of the main port." ::= { optixRtnNonCascadePLAParameterEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.240.1.5 optixRtnNonCascadePLAPGSlaveMemsInfo OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the slave port information of the protection group." ::= { optixRtnNonCascadePLAParameterEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.240.1.6 optixRtnNonCascadePLAPGLinkThreshold OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the minimum number of active links in the protection group." ::= { optixRtnNonCascadePLAParameterEntry 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.240.1.50 optixRtnNonCascadePLAPGRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the row status of the protection group." DEFVAL{ active } ::= { optixRtnNonCascadePLAParameterEntry 50 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.250 optixRtnNonCascadePLAPGStateTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnNonCascadePLAPGStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Describes parameters about a PLA protection group, including the current working board and the switching status of a protection group." ::= { optixRtnIFProtect 250 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.250.1 optixRtnNonCascadePLAPGStateEntry OBJECT-TYPE SYNTAX OptixRtnNonCascadePLAPGStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates status entry for a PLA protection group." INDEX{ optixRtnPhyLagPGID } ::= { optixRtnNonCascadePLAPGStateTable 1 } OptixRtnNonCascadePLAPGStateEntry ::= SEQUENCE { optixRtnNonCascadePLAMainBoardID Unsigned32, optixRtnNonCascadePLAMainSubCardID Unsigned32, optixRtnNonCascadePLAMainPortID Unsigned32, optixRtnNonCascadePLAMainHardStatus OPTIXRtnPhyLagPGStatus, optixRtnNonCascadePLAMainLinkStatus OPTIXRtnPhyLagPGStatus, optixRtnNonCascadePLAMainPuWorkStatus OPTIXRtnPhyLagPGStateWorkStatus, optixRtnNonCascadePLASlavePuNum Unsigned32, optixRtnNonCascadePLAPu1BoardID Unsigned32, optixRtnNonCascadePLAPu1SubCardID Unsigned32, optixRtnNonCascadePLAPu1PortID Unsigned32, optixRtnNonCascadePLAPu1HardStatus OPTIXRtnPhyLagPGStatus, optixRtnNonCascadePLAPu1LinkStatus OPTIXRtnPhyLagPGStatus, optixRtnNonCascadePLAPu1WorkStatus OPTIXRtnPhyLagPGStateWorkStatus } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.250.1.1 optixRtnNonCascadePLAMainBoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the main unit slot ID." ::= { optixRtnNonCascadePLAPGStateEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.250.1.2 optixRtnNonCascadePLAMainSubCardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the main unit subboard ID." ::= { optixRtnNonCascadePLAPGStateEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.250.1.3 optixRtnNonCascadePLAMainPortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the main unit port ID." ::= { optixRtnNonCascadePLAPGStateEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.250.1.4 optixRtnNonCascadePLAMainHardStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the hardware status of the main unit. The values: 0: normal 1: abnormal -1: unknown" ::= { optixRtnNonCascadePLAPGStateEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.250.1.5 optixRtnNonCascadePLAMainLinkStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the link status of the main unit. Values: 0: normal 1: abnormal -1: unknown" ::= { optixRtnNonCascadePLAPGStateEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.250.1.6 optixRtnNonCascadePLAMainPuWorkStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStateWorkStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the working status of the main unit. Values: 0: slave port 1: main port" ::= { optixRtnNonCascadePLAPGStateEntry 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.250.1.7 optixRtnNonCascadePLASlavePuNum OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the number of slave units. Value range: 1 to 3" ::= { optixRtnNonCascadePLAPGStateEntry 7 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.250.1.8 optixRtnNonCascadePLAPu1BoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 1 slot ID." ::= { optixRtnNonCascadePLAPGStateEntry 8 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.250.1.9 optixRtnNonCascadePLAPu1SubCardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 1 subboard ID." ::= { optixRtnNonCascadePLAPGStateEntry 9 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.250.1.10 optixRtnNonCascadePLAPu1PortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 1 port ID." ::= { optixRtnNonCascadePLAPGStateEntry 10 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.250.1.11 optixRtnNonCascadePLAPu1HardStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 1 hardware status. Values: 0: normal 1: abnormal -1: unknown" ::= { optixRtnNonCascadePLAPGStateEntry 11 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.250.1.12 optixRtnNonCascadePLAPu1LinkStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 1 link status. Values: 0: normal 1: abnormal -1: unknown" ::= { optixRtnNonCascadePLAPGStateEntry 12 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.250.1.13 optixRtnNonCascadePLAPu1WorkStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStateWorkStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave unit 1 working status. Values: 0: slave port 1: main port" ::= { optixRtnNonCascadePLAPGStateEntry 13 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.260 optixRtnPlaMinuplkthExtTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnPlaMinuplkthExtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Pla Minuplkth Table ." ::= { optixRtnIFProtect 260 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.260.1 optixRtnPlaMinuplkthExtEntry OBJECT-TYPE SYNTAX OptixRtnPlaMinuplkthExtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Pla Minuplkth Entry" INDEX{ optixRtnIndex1 } ::= { optixRtnPlaMinuplkthExtTable 1 } OptixRtnPlaMinuplkthExtEntry ::= SEQUENCE { optixRtnIPGMinuplink Unsigned32 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.260.1.1 optixRtnIPGMinuplink OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicats the protection Pla Minuplkth." ::= { optixRtnPlaMinuplkthExtEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.280 optixRtnPlaWtrTimeTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnPlaWtrTimeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Pla wtr-time Table ." ::= { optixRtnIFProtect 280 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.280.1 optixRtnPlaWtrTimeEntry OBJECT-TYPE SYNTAX OptixRtnPlaWtrTimeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Pla wtr-time Entry" INDEX{ optixRtnIndex1 } ::= { optixRtnPlaWtrTimeTable 1 } OptixRtnPlaWtrTimeEntry ::= SEQUENCE { optixRtnEplaWtrState INTEGER, optixRtnEplaWtrTime Unsigned32 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.280.1.2 optixRtnEplaWtrState OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicats the protection Pla wtr-state." ::= { optixRtnPlaWtrTimeEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.280.1.3 optixRtnEplaWtrTime OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicats the protection Pla wtr-time." ::= { optixRtnPlaWtrTimeEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.281 optixRtnPlaForceSwitchTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnPlaForceSwitchEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Pla Force Switch Table." ::= { optixRtnIFProtect 281 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.281.1 optixRtnPlaForceSwitchEntry OBJECT-TYPE SYNTAX OptixRtnPlaForceSwitchEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Pla Force Switch Entry" INDEX{ optixRtnPlaGroupIndex, optixRtnPlaBoardIndex, optixRtnPlaSubboardIndex, optixRtnPlaPortIndex, optixPlaChannelIdIndex} ::= { optixRtnPlaForceSwitchTable 1 } OptixRtnPlaForceSwitchEntry ::= SEQUENCE { optixRtnPlaGroupIndex Unsigned32, optixRtnPlaBoardIndex Unsigned32, optixRtnPlaSubboardIndex Unsigned32, optixRtnPlaPortIndex Unsigned32, optixPlaChannelIdIndex Unsigned32, optixRtnPlaForceSwitchLocalStatus INTEGER, optixRtnPlaForceSwitchRemoteStatus INTEGER } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.281.1.1 optixRtnPlaGroupIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the Pla groupIndex." ::= { optixRtnPlaForceSwitchEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.281.1.2 optixRtnPlaBoardIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the Pla boardIndex." ::= { optixRtnPlaForceSwitchEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.281.1.3 optixRtnPlaSubboardIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the Pla subboardIndex." ::= { optixRtnPlaForceSwitchEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.281.1.4 optixRtnPlaPortIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the Pla portIndex." ::= { optixRtnPlaForceSwitchEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.281.1.5 optixPlaChannelIdIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the Pla ChannelIdIndex." ::= { optixRtnPlaForceSwitchEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.281.1.6 optixRtnPlaForceSwitchLocalStatus OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicats the protection Pla Force Switch Local Status." ::= { optixRtnPlaForceSwitchEntry 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.281.1.7 optixRtnPlaForceSwitchRemoteStatus OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicats the protection Pla Force Switch Remote Status." ::= { optixRtnPlaForceSwitchEntry 7 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.290 optixRtnComboStatTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnComboStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "combo port Table ." ::= { optixRtnIFProtect 290 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.290.1 optixRtnComboStatEntry OBJECT-TYPE SYNTAX OptixRtnComboStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "combo port Entry" INDEX{ optixRtnIndex1,optixRtnIndex2,optixRtnIndex3 } ::= { optixRtnComboStatTable 1 } OptixRtnComboStatEntry ::= SEQUENCE { optixRtnComboState INTEGER } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.290.1.4 optixRtnComboState OBJECT-TYPE SYNTAX INTEGER { disable(0), xpic(1), ca(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicats the combo port state." ::= { optixRtnComboStatEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.300 optixRtnPLAGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnPLAGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Describes configuration parameters for the working board and protection board in a Test PLA protection group." ::= { optixRtnIFProtect 300 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.300.1 optixRtnPLAGroupEntry OBJECT-TYPE SYNTAX OptixRtnPLAGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the parameter entry for a Test PLA protection group." INDEX{ optixRtnIndex1 } ::= { optixRtnPLAGroupTable 1 } OptixRtnPLAGroupEntry ::= SEQUENCE { optixRtnPLAGroupID Unsigned32, optixRtnPLAGroupMainBoardID Unsigned32, optixRtnPLAGroupMainSubCardID Unsigned32, optixRtnPLAGroupMainPortID Unsigned32, optixRtnPLAGroupCascadingPuNum Unsigned32, optixRtnPLAGroupPu1BoardID Unsigned32, optixRtnPLAGroupPu1SubCardID Unsigned32, optixRtnPLAGroupPu1PortID Unsigned32, optixRtnPLAGroupCfgRowStatus RowStatus } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.300.1.1 optixRtnPLAGroupID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicats the protection group ID." ::= { optixRtnPLAGroupEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.300.1.2 optixRtnPLAGroupMainBoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the slot ID of the main unit." ::= { optixRtnPLAGroupEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.300.1.3 optixRtnPLAGroupMainSubCardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the subboard ID of the main unit." ::= { optixRtnPLAGroupEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.300.1.4 optixRtnPLAGroupMainPortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the port ID of the main unit." ::= { optixRtnPLAGroupEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.300.1.5 optixRtnPLAGroupCascadingPuNum OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the number of Test ports. Value range: 1 to 3" DEFVAL{ 1 } ::= { optixRtnPLAGroupEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.300.1.6 optixRtnPLAGroupPu1BoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the board ID of the Test unit 1." ::= { optixRtnPLAGroupEntry 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.300.1.7 optixRtnPLAGroupPu1SubCardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the subboard ID of the Test unit 1." ::= { optixRtnPLAGroupEntry 7 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.300.1.8 optixRtnPLAGroupPu1PortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the port ID of the Test unit 1." ::= { optixRtnPLAGroupEntry 8 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.300.1.50 optixRtnPLAGroupCfgRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the row status of a protection group" DEFVAL{ active } ::= { optixRtnPLAGroupEntry 50 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.340 optixRtnEnergySaveStrategyTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnEnergySaveStrategyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicate the table of energysave strategy" ::= { optixRtnIFProtect 340 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.340.1 optixRtnEnergySaveStrategyEntry OBJECT-TYPE SYNTAX OptixRtnEnergySaveStrategyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the entries of energysave strategy" INDEX {optixRtnStrategyGroupID} ::= { optixRtnEnergySaveStrategyTable 1 } OptixRtnEnergySaveStrategyEntry ::= SEQUENCE { optixRtnStrategyGroupID Unsigned32, optixRtnStrategyState INTEGER, optixRtnStrategyType OPTIXRtnStrategyType, optixRtnStrategyHighThresHold Unsigned32, optixRtnStrategyLowThresHold Unsigned32, optixRtnStrategyStartHoldTime Unsigned32, optixRtnStrategyEndHoldTime Unsigned32, optixRtnStrategyStartTime Unsigned32, optixRtnStrategyEndTime Unsigned32, optixRtnStrategyCfgRowStatus RowStatus } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.340.1.1 optixRtnStrategyGroupID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the energysave group ID" ::= { optixRtnEnergySaveStrategyEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.340.1.2 optixRtnStrategyState OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the state of the energysave group" DEFVAL{0} ::= { optixRtnEnergySaveStrategyEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.340.1.3 optixRtnStrategyType OBJECT-TYPE SYNTAX OPTIXRtnStrategyType MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the type of energy save group. 0: green" DEFVAL{0} ::= { optixRtnEnergySaveStrategyEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.340.1.4 optixRtnStrategyHighThresHold OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the high threshold of energysave group. Range:(0 ~ 100), low < high" ::= { optixRtnEnergySaveStrategyEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.340.1.5 optixRtnStrategyLowThresHold OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the low threshold of energysave group. Range:(0 ~ 100]), low < high" ::= { optixRtnEnergySaveStrategyEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.340.1.6 optixRtnStrategyStartHoldTime OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Inidcates the start filt time of energysave. Unit: second, range:[0,3600]." ::= { optixRtnEnergySaveStrategyEntry 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.340.1.7 optixRtnStrategyEndHoldTime OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Inidcates the end filt time of energysave. Unit: second, range:[0,3600]." ::= { optixRtnEnergySaveStrategyEntry 7 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.340.1.8 optixRtnStrategyStartTime OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Inidcates the start time of energysave. Unit: minute, range:[0,1439]." ::= { optixRtnEnergySaveStrategyEntry 8 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.340.1.9 optixRtnStrategyEndTime OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Inidcates the end time of energysave. Unit: minute, range:[0,1439]." ::= { optixRtnEnergySaveStrategyEntry 9 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.340.1.50 optixRtnStrategyCfgRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the row status of a energysave group." DEFVAL{ active } ::= { optixRtnEnergySaveStrategyEntry 50 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.341 optixRtnEnergySaveMemberTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnEnergySaveMemberEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Describes the members of energysave strategy group." ::= { optixRtnIFProtect 341 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.341.1 optixRtnEnergySaveMemberEntry OBJECT-TYPE SYNTAX OptixRtnEnergySaveMemberEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the member entry of energysave strategy group." INDEX{ optixRtnStrategyGroupMemberID } ::= { optixRtnEnergySaveMemberTable 1 } OptixRtnEnergySaveMemberEntry ::= SEQUENCE { optixRtnStrategyGroupMemberID Unsigned32, optixRtnMemberInfo OCTET STRING, optixRtnMemberInfoDel OCTET STRING } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.341.1.1 optixRtnStrategyGroupMemberID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the member ID of energysave strategy group." ::= { optixRtnEnergySaveMemberEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.341.1.2 optixRtnMemberInfo OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates or adds the member info of energysave strategy group. Params:memberNum,boardId1,subboardId1,portId1,carrierId1,boardId2,subboardId2,portId2,carrierId2,..." ::= { optixRtnEnergySaveMemberEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.341.1.3 optixRtnMemberInfoDel OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-create STATUS current DESCRIPTION "Deletes the member info of energysave strategy group. Params:memberNum,boardId1,subboardId1,portId1,carrierId1,boardId2,subboardId2,portId2,carrierId2,..." ::= { optixRtnEnergySaveMemberEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20 optixRtnProtectTrapCommon OBJECT IDENTIFIER ::= { optixRtnIFProtectMgr 20 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.1 optixRptRtn1j1PGEvent OBJECT IDENTIFIER ::= { optixRtnProtectTrapCommon 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.1.1 optixRptRtn1j1PGID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the IF 1+1 protection group ID." ::= { optixRptRtn1j1PGEvent 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.1.2 optixRptRtn1j1PGCurrWorkBoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the current working slot ID of an IF 1+1 protection group." ::= { optixRptRtn1j1PGEvent 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.1.3 optixRptRtn1j1PGCurrWorkSubCardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the current working subboard ID of an IF 1+1 protection group." ::= { optixRptRtn1j1PGEvent 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.1.4 optixRptRtn1j1PGCurrWorkPortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the current working port ID of an IF 1+1 protection group." ::= { optixRptRtn1j1PGEvent 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.1.5 optixRptRtn1j1PGCurrWorkChannel OBJECT-TYPE SYNTAX OPTIXRtnCascading1j1PGRoleType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the current working channel identifier of an IF 1+1 protection group." ::= { optixRptRtn1j1PGEvent 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.1.6 optixRptRtn1j1PGMainBoardState OBJECT-TYPE SYNTAX OPTIXRtn1j1PGBDStateType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the working status of the main board in an IF 1+1 protection group." ::= { optixRptRtn1j1PGEvent 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.1.7 optixRptRtn1j1PGBackupBoardState OBJECT-TYPE SYNTAX OPTIXRtn1j1PGBDStateType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the working status of the standby board in an IF 1+1 protection group." ::= { optixRptRtn1j1PGEvent 7 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.1.8 optixRptRtn1j1PGSwitchRequest OBJECT-TYPE SYNTAX OPTIXRtn1j1SwtichRequestType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the switching request of an IF 1+1 protection group." ::= { optixRptRtn1j1PGEvent 8 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.10 optixRptRtnNj1PGEvent OBJECT IDENTIFIER ::= { optixRtnProtectTrapCommon 10 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.10.1 optixRptRtnNj1PGID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the IF N+1 protection group ID." ::= { optixRptRtnNj1PGEvent 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.10.2 optixRptRtnNj1Channel OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the channel ID of an IF N+1 protection group." ::= { optixRptRtnNj1PGEvent 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.10.3 optixRptRtnNj1PGSwitchRequest OBJECT-TYPE SYNTAX OPTIXRtnNj1PGSwitchRequestType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the switching request of an IF N+1 protection group." ::= { optixRptRtnNj1PGEvent 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.10.4 optixRptRtnNj1PGSwitchState OBJECT-TYPE SYNTAX OPTIXRtnNj1SwitchStateType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the switching status of an IF N+1 protection group." ::= { optixRptRtnNj1PGEvent 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.10.5 optixRptRtnNj1PGProtectedPath OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the protected unit of an IF N+1 protection group." ::= { optixRptRtnNj1PGEvent 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.10.6 optixRptRtnNj1PGFarNearIndicate OBJECT-TYPE SYNTAX OPTIXRtnNj1PGFarNearType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the switching far and near ends of an IF N+1 protection group." ::= { optixRptRtnNj1PGEvent 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.10.7 optixRptRtnNj1PGSwitchReason OBJECT-TYPE SYNTAX OPTIXRtnNj1PGSwitchReasonType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the switching causes for an IF N+1 protection group." ::= { optixRptRtnNj1PGEvent 7 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.20 optixRptRtnPLAPGEvent OBJECT IDENTIFIER ::= { optixRtnProtectTrapCommon 20 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.20.1 optixRptRtnPLAPGID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the ID of a PLA protection group." ::= { optixRptRtnPLAPGEvent 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.20.2 optixRptRtnPLAPGMainBoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the main unit slot ID of a PLA protection group." ::= { optixRptRtnPLAPGEvent 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.20.3 optixRptRtnPLAPGMainSubCardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the main unit slot ID of a PLA protection group." ::= { optixRptRtnPLAPGEvent 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.20.4 optixRptRtnPLAPGMainPortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the main unit port ID of a PLA protection group." ::= { optixRptRtnPLAPGEvent 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.20.5 optixRptRtnPLAPGMainHardStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStatus MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the main unit hardware status of a PLA protection group." ::= { optixRptRtnPLAPGEvent 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.20.6 optixRptRtnPLAPGMainLinkStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStatus MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the main unit link status of a PLA protection group." ::= { optixRptRtnPLAPGEvent 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.20.7 optixRptRtnPLAPGMainWorkStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStateWorkStatus MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the main unit switching status of a PLA protection group." ::= { optixRptRtnPLAPGEvent 7 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.20.8 optixRptRtnPLAPGSlavePortNum OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the number of slave units in a PLA protection group." ::= { optixRptRtnPLAPGEvent 8 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.20.9 optixRptRtnPLAPGSlaveStatus OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the slave units switching status of a PLA protection group." ::= { optixRptRtnPLAPGEvent 9 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.240 optixRptRtnPLAPGScheduleModeChangeEvent OBJECT IDENTIFIER ::= { optixRtnProtectTrapCommon 240 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.240.1 optixRptRtnPLAPGId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the ID of a PLA protection group." ::= { optixRptRtnPLAPGScheduleModeChangeEvent 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.240.2 optixRptRtnPLAPGType OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the Type of a PLA protection group." ::= { optixRptRtnPLAPGScheduleModeChangeEvent 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.240.3 optixRptRtnPLAPGCfgMode OBJECT-TYPE SYNTAX Unsigned32 { modeA(0), modeB(1), modeAAccess(2), unknown(255) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the CfgMode of a PLA protection group." ::= { optixRptRtnPLAPGScheduleModeChangeEvent 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.240.4 optixRptRtnPLAPGWorkMode OBJECT-TYPE SYNTAX Unsigned32 { modeA(0), modeB(1), modeAAccess(2), unknown(255) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the WorkMode of a PLA protection group." ::= { optixRptRtnPLAPGScheduleModeChangeEvent 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.30 optixRptRtnCascading1j1PGEvent OBJECT IDENTIFIER ::= { optixRtnProtectTrapCommon 30 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.30.1 optixRptRtnC1j1PGID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the cascading IF 1+1 protection group ID." ::= { optixRptRtnCascading1j1PGEvent 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.30.2 optixRptRtnC1j1PGWorkNEID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the current working NE ID of a cascading IF 1+1 protection group on the equipment side." ::= { optixRptRtnCascading1j1PGEvent 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.30.3 optixRptRtnC1j1PGWorkBoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the current working board ID of a cascading IF 1+1 protection group on the equipment side." ::= { optixRptRtnCascading1j1PGEvent 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.30.4 optixRptRtnC1j1PGWorkSubCardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the current working subboard ID of a cascading IF 1+1 protection group on the equipment side." ::= { optixRptRtnCascading1j1PGEvent 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.30.5 optixRptRtnC1j1PGWorkPortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the current working port ID of a cascading IF 1+1 protection group on the equipment side." ::= { optixRptRtnCascading1j1PGEvent 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.30.6 optixRptRtnC1j1PGCurrWorkChannel OBJECT-TYPE SYNTAX OPTIXRtnCascading1j1PGRoleType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the current working channel identifier of an cascading IF 1+1 protection group." ::= { optixRptRtnCascading1j1PGEvent 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.30.7 optixRptRtnC1j1PGWorkBoardState OBJECT-TYPE SYNTAX OPTIXRtn1j1PGBDStateType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the working status of the main board on the equipment side. Values: 0: normal 1: switching 2: RDI switching -1: unknown" ::= { optixRptRtnCascading1j1PGEvent 7 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.30.8 optixRptRtnC1j1PGProtectBoardState OBJECT-TYPE SYNTAX OPTIXRtn1j1PGBDStateType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the working status of the standby board on the equipment side. Values: 0: normal 1: switching 2: RDI switching -1: unknown" ::= { optixRptRtnCascading1j1PGEvent 8 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.30.9 optixRptRtnC1j1PGSwtichRequest OBJECT-TYPE SYNTAX OPTIXRtn1j1SwtichRequestType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the switching request on the equipment side. Value range: 0: normal 1: automatic 2: manual 3: forced 4: lockout 5: wait to restore 6: RDI" ::= { optixRptRtnCascading1j1PGEvent 9 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.40 optixRptRtnCascadingPLAPGEvent OBJECT IDENTIFIER ::= { optixRtnProtectTrapCommon 40 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.40.1 optixRptRtnCPLAPGID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the cascading PLA protection group ID." ::= { optixRptRtnCascadingPLAPGEvent 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.40.2 optixRptRtnCPLAPGMainNEID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the main NE ID." ::= { optixRptRtnCascadingPLAPGEvent 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.40.3 optixRptRtnCPLAPGMainBoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the slot ID of the main unit." ::= { optixRptRtnCascadingPLAPGEvent 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.40.4 optixRptRtnCPLAPGMainSubID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the subboard ID of the main unit." ::= { optixRptRtnCascadingPLAPGEvent 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.40.5 optixRptRtnCPLAPGMainPortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the port ID of the main unit." ::= { optixRptRtnCascadingPLAPGEvent 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.40.6 optixRptRtnCPLAPGMainHardStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStatus MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the hardware status of the main unit. The values: 0: normal 1: abnormal -1: unknown" ::= { optixRptRtnCascadingPLAPGEvent 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.40.7 optixRptRtnCPLAPGMainLinkStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStatus MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the link status of the main unit. The values: 0: normal 1: abnormal -1: unknown" ::= { optixRptRtnCascadingPLAPGEvent 7 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.40.8 optixRptRtnCPLAPGMainMSStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStateWorkStatus MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the working status of the main unit. Values: 0: slave port 1: main port" ::= { optixRptRtnCascadingPLAPGEvent 8 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.40.9 optixRptRtnCPLAPGSlavePuNum OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the number of cascading units. Value range: 1 to 3" ::= { optixRptRtnCascadingPLAPGEvent 9 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.40.10 optixRptRtnCPLAPGPu1NEID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the NE ID of the cascading unit 1." ::= { optixRptRtnCascadingPLAPGEvent 10 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.40.11 optixRptRtnCPLAPGPu1BoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the board ID of the cascading unit 1. An invalid value of 65535 is returned when the adjacency channel is faulty." ::= { optixRptRtnCascadingPLAPGEvent 11 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.40.12 optixRptRtnCPLAPGPu1SubCardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the subboard ID of the cascading unit 1. An invalid value of 255 is returned when the adjacency channel is faulty." ::= { optixRptRtnCascadingPLAPGEvent 12 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.40.13 optixRptRtnCPLAPGPu1PortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the port ID of the cascading unit 1. An invalid value of 255 is returned when the adjacency channel is faulty." ::= { optixRptRtnCascadingPLAPGEvent 13 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.40.14 optixRptRtnCPLAPGPu1HardStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStatus MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the hardware status of the cascading unit 1. Values: 0: normal 1: abnormal -1: unknown" ::= { optixRptRtnCascadingPLAPGEvent 14 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.40.15 optixRptRtnCPLAPGPu1LinkStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStatus MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the link status of the cascading unit 1. Values: 0: normal 1: abnormal -1: unknown" ::= { optixRptRtnCascadingPLAPGEvent 15 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.40.16 optixRptRtnCPLAPGPu1MSStatus OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGStateWorkStatus MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the working status of the cascading unit 1. Values: 0: slave port 1: main port" ::= { optixRptRtnCascadingPLAPGEvent 16 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.41 optixRtnNonCascade1J1SwitchEvent OBJECT IDENTIFIER ::= { optixRtnProtectTrapCommon 41 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.41.1 optixRtnNonCascade1J1GPID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the protection group ID." ::= { optixRtnNonCascade1J1SwitchEvent 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.41.2 optixRtnNonCascade1J1BoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the slot ID of the current working board on the equipment side." ::= { optixRtnNonCascade1J1SwitchEvent 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.41.3 optixRtnNonCascade1J1SubCardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the subcard ID of the current working board on the equipment side." ::= { optixRtnNonCascade1J1SwitchEvent 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.41.4 optixRtnNonCascade1J1PortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the port ID of the current working board on the equipment side." ::= { optixRtnNonCascade1J1SwitchEvent 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.41.5 optixRtnNonCascade1J1DevWorkBoardProperty OBJECT-TYPE SYNTAX OPTIXRtn1j1DevWorkBoardProperty MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates whether the current working board on the equipment board is a working or protection board. The values are as follows: 0-working 1-protection" ::= { optixRtnNonCascade1J1SwitchEvent 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.41.6 optixRtnNonCascade1J1WorkBoardDevState OBJECT-TYPE SYNTAX OPTIXRtn1j1PGBDStateType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the status of the current working board on the equipment side. The values are as follows: 0-normal 1-fail 2-rdi 255-unknown" ::= { optixRtnNonCascade1J1SwitchEvent 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.41.7 optixRtnNonCascade1J1ProtBoardDevState OBJECT-TYPE SYNTAX OPTIXRtn1j1PGBDStateType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the status of the current protection board on the equipment side. The values are as follows: 0-normal 1-fail 2-rdi 255-unknown" ::= { optixRtnNonCascade1J1SwitchEvent 7 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.41.8 optixRtnNonCascade1J1DevSwtichRequest OBJECT-TYPE SYNTAX OPTIXRtn1j1SwtichRequestType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the equipment-side switching request: 0-state-normal 1-state-auto 2-state-manual 3-state-force 4-state-lockout 5-state-wtr 6-state-rdi" ::= { optixRtnNonCascade1J1SwitchEvent 8 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.43 optixRtnIFBitErrorCodeTestEvent OBJECT IDENTIFIER ::= { optixRtnProtectTrapCommon 43 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.43.1 optixRtnIFBECTBoardId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the slot ID of the IF board." ::= { optixRtnIFBitErrorCodeTestEvent 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.43.2 optixRtnIFBECTSubCardId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the subcard ID." ::= { optixRtnIFBitErrorCodeTestEvent 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.43.3 optixRtnIFBECTPortId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the port ID." ::= { optixRtnIFBitErrorCodeTestEvent 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.43.4 optixRtnIFBECTType OBJECT-TYPE SYNTAX INTEGER { e1(1), if(2), cpri(3) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the test type: 1-E1 2-IF 3-CPRI" ::= { optixRtnIFBitErrorCodeTestEvent 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.43.5 optixRtnIFBECTPathId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the path ID. Set the parameter to 0 if this field is not in use." ::= { optixRtnIFBitErrorCodeTestEvent 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.43.6 optixRtnIFBECTDirection OBJECT-TYPE SYNTAX INTEGER { ingressDir(1), egressDir(2) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the test direction: 1-Ingress 2-Egress" ::= { optixRtnIFBitErrorCodeTestEvent 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.43.7 optixRtnIFBECTMode OBJECT-TYPE SYNTAX INTEGER { shortTerm(1), longTerm(2), longlongTerm(3) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the test type. 1: short-term test 2: long-term test 3: super long-term test" ::= { optixRtnIFBitErrorCodeTestEvent 7 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.43.8 optixRtnIFBECTTimeStamp OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The value starts from 0x0001. The test duration is measured in seconds in short-term tests and minutes in long-term tests and super-long-term tests." ::= { optixRtnIFBitErrorCodeTestEvent 8 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.43.9 optixRtnIFBECTStartTime OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the start time of a test in the format of YYYYMMDDHHMMSS and the time starts from the year 1990." ::= { optixRtnIFBitErrorCodeTestEvent 9 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.43.10 optixRtnIFBECTCurTime OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the current time of a test in the format of YYYYMMDDHHMMSS and the time starts from the year 1990." ::= { optixRtnIFBitErrorCodeTestEvent 10 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.43.11 optixRtnIFBECTProgress OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the test progress. Value range: 1-100" ::= { optixRtnIFBitErrorCodeTestEvent 11 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.43.12 optixRtnIFBECTDataTypeNum OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the number of parameter types N (N >= 1 and currently N = 2). The data types are described as follows:" ::= { optixRtnIFBitErrorCodeTestEvent 12 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.43.13 optixRtnIFBECTType1 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The data types are as follows: 1: number of bit errors 2: BER (calculated based on the number of bit errors) 3: errored second 4: severely errored second 5: unavailable second 6: background block error" ::= { optixRtnIFBitErrorCodeTestEvent 13 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.43.14 optixRtnIFBECTTestResult1 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the statistics. Each 5-byte string represents the accumulative value for a certain type of statistics data. The first byte indicates the data type and the other four bytes indicate the accumulative value." ::= { optixRtnIFBitErrorCodeTestEvent 14 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.43.15 optixRtnIFBECTType2 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The data types are as follows: 1: number of bit errors 2: BER (calculated based on the number of bit errors) 3: errored second 4: severely errored second 5: unavailable second 6: background block error" ::= { optixRtnIFBitErrorCodeTestEvent 15 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.43.16 optixRtnIFBECTTestResult2 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the statistics. Each 5-byte string represents the accumulative value for a certain type of statistics data. The first byte indicates the data type and the other four bytes indicate the accumulative value." ::= { optixRtnIFBitErrorCodeTestEvent 16 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.43.17 optixRtnIFBECTType3 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The data types are as follows: 1: number of bit errors 2: BER (calculated based on the number of bit errors) 3: errored second 4: severely errored second 5: unavailable second 6: background block error" ::= { optixRtnIFBitErrorCodeTestEvent 17 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.43.18 optixRtnIFBECTTestResult3 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the statistics. Each 5-byte string represents the accumulative value for a certain type of statistics data. The first byte indicates the data type and the other four bytes indicate the accumulative value." ::= { optixRtnIFBitErrorCodeTestEvent 18 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.43.19 optixRtnIFBECTType4 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The data types are as follows: 1: number of bit errors 2: BER (calculated based on the number of bit errors) 3: errored second 4: severely errored second 5: unavailable second 6: background block error" ::= { optixRtnIFBitErrorCodeTestEvent 19 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.43.20 optixRtnIFBECTTestResult4 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the statistics. Each 5-byte string represents the accumulative value for a certain type of statistics data. The first byte indicates the data type and the other four bytes indicate the accumulative value." ::= { optixRtnIFBitErrorCodeTestEvent 20 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.43.21 optixRtnIFBECTType5 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The data types are as follows: 1: number of bit errors 2: BER (calculated based on the number of bit errors) 3: errored second 4: severely errored second 5: unavailable second 6: background block error" ::= { optixRtnIFBitErrorCodeTestEvent 21 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.43.22 optixRtnIFBECTTestResult5 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the statistics. Each 5-byte string represents the accumulative value for a certain type of statistics data. The first byte indicates the data type and the other four bytes indicate the accumulative value." ::= { optixRtnIFBitErrorCodeTestEvent 22 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.43.23 optixRtnIFBECTType6 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The data types are as follows: 1: number of bit errors 2: BER (calculated based on the number of bit errors) 3: errored second 4: severely errored second 5: unavailable second 6: background block error" ::= { optixRtnIFBitErrorCodeTestEvent 23 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.43.24 optixRtnIFBECTTestResult6 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the statistics. Each 5-byte string represents the accumulative value for a certain type of statistics data. The first byte indicates the data type and the other four bytes indicate the accumulative value." ::= { optixRtnIFBitErrorCodeTestEvent 24 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.46 optixRtnIFBitOldTestEvent OBJECT IDENTIFIER ::= { optixRtnProtectTrapCommon 46 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.46.1 optixRtnBECTBoardId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the slot ID of the IF board." ::= { optixRtnIFBitOldTestEvent 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.46.2 optixRtnBECTSubCardId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the subcard ID." ::= { optixRtnIFBitOldTestEvent 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.46.3 optixRtnBECTPortId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the port ID." ::= { optixRtnIFBitOldTestEvent 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.46.4 optixRtnBECTTimeStamp OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The value starts from 0x0001. The test duration is measured in seconds in short-term tests and minutes in long-term tests and super-long-term tests." ::= { optixRtnIFBitOldTestEvent 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.46.5 optixRtnBECTErrorNum OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the number of error ." ::= { optixRtnIFBitOldTestEvent 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.47 optixRtnIFBitTestEvent OBJECT IDENTIFIER ::= { optixRtnProtectTrapCommon 47 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.47.1 optixRtnIFBITTESTBoardId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the slot ID of the IF board." ::= { optixRtnIFBitTestEvent 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.47.2 optixRtnIFBITTESTSubCardId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the subcard ID." ::= { optixRtnIFBitTestEvent 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.47.3 optixRtnIFBITTESTPortId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the port ID." ::= { optixRtnIFBitTestEvent 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.47.4 optixRtnIFBITTESTMode OBJECT-TYPE SYNTAX INTEGER { shortTerm(1), longTerm(2), longlongTerm(3) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the test type. 1: short-term test 2: long-term test 3: super long-term test" ::= { optixRtnIFBitTestEvent 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.47.5 optixRtnIFBITTESTTimeStamp OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The value starts from 0x0001. The test duration is measured in seconds in short-term tests and minutes in long-term tests and hours in super-long-term tests." ::= { optixRtnIFBitTestEvent 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.47.6 optixRtnIFBITTESTStartTime OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the start time of a test in the format of YYYYMMDDHHMMSS and the time starts from the year 1990." ::= { optixRtnIFBitTestEvent 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.47.7 optixRtnIFBITTESTCurTime OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the current time of a test in the format of YYYYMMDDHHMMSS and the time starts from the year 1990." ::= { optixRtnIFBitTestEvent 7 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.47.8 optixRtnIFBITTESTProgress OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the test progress. Value range: 1-100" ::= { optixRtnIFBitTestEvent 8 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.47.9 optixRtnIFBITTESTDataTypeNum OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the number of parameter types N (N >= 1 and currently N = 2). The data types are described as follows:" ::= { optixRtnIFBitTestEvent 9 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.47.10 optixRtnIFBITTESTType1 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The data types are as follows: 1: number of bit errors 2: BER (calculated based on the number of bit errors) 3: errored second 4: severely errored second 5: unavailable second 6: background block error" ::= { optixRtnIFBitTestEvent 10 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.47.11 optixRtnIFBITTESTTestResult1 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the statistics. Each 5-byte string represents the accumulative value for a certain type of statistics data. The first byte indicates the data type and the other four bytes indicate the accumulative value." ::= { optixRtnIFBitTestEvent 11 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.47.12 optixRtnIFBITTESTType2 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The data types are as follows: 1: number of bit errors 2: BER (calculated based on the number of bit errors) 3: errored second 4: severely errored second 5: unavailable second 6: background block error" ::= { optixRtnIFBitTestEvent 12 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.47.13 optixRtnIFBITTESTTestResult2 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the statistics. Each 5-byte string represents the accumulative value for a certain type of statistics data. The first byte indicates the data type and the other four bytes indicate the accumulative value." ::= { optixRtnIFBitTestEvent 13 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.47.14 optixRtnIFBITTESTType3 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The data types are as follows: 1: number of bit errors 2: BER (calculated based on the number of bit errors) 3: errored second 4: severely errored second 5: unavailable second 6: background block error" ::= { optixRtnIFBitTestEvent 14 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.47.15 optixRtnIFBITTESTTestResult3 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the statistics. Each 5-byte string represents the accumulative value for a certain type of statistics data. The first byte indicates the data type and the other four bytes indicate the accumulative value." ::= { optixRtnIFBitTestEvent 15 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.47.16 optixRtnIFBITTESTType4 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The data types are as follows: 1: number of bit errors 2: BER (calculated based on the number of bit errors) 3: errored second 4: severely errored second 5: unavailable second 6: background block error" ::= { optixRtnIFBitTestEvent 16 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.47.17 optixRtnIFBITTESTTestResult4 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the statistics. Each 5-byte string represents the accumulative value for a certain type of statistics data. The first byte indicates the data type and the other four bytes indicate the accumulative value." ::= { optixRtnIFBitTestEvent 17 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.47.18 optixRtnIFBITTESTType5 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The data types are as follows: 1: number of bit errors 2: BER (calculated based on the number of bit errors) 3: errored second 4: severely errored second 5: unavailable second 6: background block error" ::= { optixRtnIFBitTestEvent 18 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.47.19 optixRtnIFBITTESTTestResult5 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the statistics. Each 5-byte string represents the accumulative value for a certain type of statistics data. The first byte indicates the data type and the other four bytes indicate the accumulative value." ::= { optixRtnIFBitTestEvent 19 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.47.20 optixRtnIFBITTESTType6 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The data types are as follows: 1: number of bit errors 2: BER (calculated based on the number of bit errors) 3: errored second 4: severely errored second 5: unavailable second 6: background block error" ::= { optixRtnIFBitTestEvent 20 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.47.21 optixRtnIFBITTESTTestResult6 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the statistics. Each 5-byte string represents the accumulative value for a certain type of statistics data. The first byte indicates the data type and the other four bytes indicate the accumulative value." ::= { optixRtnIFBitTestEvent 21 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.48 optixRtnIFBitErrorCodeExTestEvent OBJECT IDENTIFIER ::= { optixRtnProtectTrapCommon 48 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.48.1 optixRtnIFBitEXTestBoardId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the slot ID of the IF board." ::= { optixRtnIFBitErrorCodeExTestEvent 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.48.2 optixRtnIFBitEXTestSubCardId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the subcard ID." ::= { optixRtnIFBitErrorCodeExTestEvent 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.48.3 optixRtnIFBitEXTestPortId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the port ID." ::= { optixRtnIFBitErrorCodeExTestEvent 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.48.4 optixRtnIFBitEXTestMode OBJECT-TYPE SYNTAX INTEGER { shortTerm(1), longTerm(2), longlongTerm(3) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the test type. 1: short-term test 2: long-term test 3: super long-term test" ::= { optixRtnIFBitErrorCodeExTestEvent 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.48.5 optixRtnIFBitEXTestTimeStamp OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The value starts from 0x0001. The test duration is measured in seconds in short-term tests and minutes in long-term tests and super-long-term tests." ::= { optixRtnIFBitErrorCodeExTestEvent 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.48.6 optixRtnIFBitEXTestStartTime OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the start time of a test in the format of YYYYMMDDHHMMSS and the time starts from the year 1990." ::= { optixRtnIFBitErrorCodeExTestEvent 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.48.7 optixRtnIFBitEXTestCurTime OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the current time of a test in the format of YYYYMMDDHHMMSS and the time starts from the year 1990." ::= { optixRtnIFBitErrorCodeExTestEvent 7 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.48.8 optixRtnIFBitEXTestProgress OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the test progress. Value range: 1-100" ::= { optixRtnIFBitErrorCodeExTestEvent 8 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.48.9 optixRtnIFBitEXTestDataTypeNum OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the number of parameter types N (N >= 1 and currently N = 2). The data types are described as follows:" ::= { optixRtnIFBitErrorCodeExTestEvent 9 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.48.10 optixRtnIFBitEXTestType1 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The data types are as follows: 1: number of bit errors 2: BER (calculated based on the number of bit errors) 3: errored second 4: severely errored second 5: unavailable second 6: background block error" ::= { optixRtnIFBitErrorCodeExTestEvent 10 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.48.11 optixRtnIFBitEXTestTestResult1 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the statistics. Each 5-byte string represents the accumulative value for a certain type of statistics data. The first byte indicates the data type and the other four bytes indicate the accumulative value." ::= { optixRtnIFBitErrorCodeExTestEvent 11 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.48.12 optixRtnIFBitEXTestType2 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The data types are as follows: 1: number of bit errors 2: BER (calculated based on the number of bit errors) 3: errored second 4: severely errored second 5: unavailable second 6: background block error" ::= { optixRtnIFBitErrorCodeExTestEvent 12 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.48.13 optixRtnIFBitEXTestTestResult2 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the statistics. Each 5-byte string represents the accumulative value for a certain type of statistics data. The first byte indicates the data type and the other four bytes indicate the accumulative value." ::= { optixRtnIFBitErrorCodeExTestEvent 13 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.49 optixRtnE1PRBSTestEvent OBJECT IDENTIFIER ::= { optixRtnProtectTrapCommon 49 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.49.1 optixRtnE1PRBSBoardId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the slot ID of the IF board." ::= { optixRtnE1PRBSTestEvent 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.49.2 optixRtnE1PRBSSubCardId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the subcard ID." ::= { optixRtnE1PRBSTestEvent 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.49.3 optixRtnE1PRBSPortId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the port ID." ::= { optixRtnE1PRBSTestEvent 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.49.4 optixRtnE1PRBSPathId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the path ID. Set the parameter to 0 if this field is not in use." ::= { optixRtnE1PRBSTestEvent 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.49.5 optixRtnE1PRBSDirection OBJECT-TYPE SYNTAX INTEGER { ingressDir(1), egressDir(2) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the test direction: 1-Ingress 2-Egress" ::= { optixRtnE1PRBSTestEvent 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.49.6 optixRtnE1PRBSMode OBJECT-TYPE SYNTAX INTEGER { shortTerm(1), longTerm(2), longlongTerm(3) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the test type. 1: short-term test 2: long-term test 3: super long-term test" ::= { optixRtnE1PRBSTestEvent 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.49.7 optixRtnE1PRBSTimeStamp OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The value starts from 0x0001. The test duration is measured in seconds in short-term tests and minutes in long-term tests and super-long-term tests." ::= { optixRtnE1PRBSTestEvent 7 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.49.8 optixRtnE1PRBSStartTime OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the start time of a test in the format of YYYYMMDDHHMMSS and the time starts from the year 1990." ::= { optixRtnE1PRBSTestEvent 8 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.49.9 optixRtnE1PRBSCurTime OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the current time of a test in the format of YYYYMMDDHHMMSS and the time starts from the year 1990." ::= { optixRtnE1PRBSTestEvent 9 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.49.10 optixRtnE1PRBSProgress OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the test progress. Value range: 1-100" ::= { optixRtnE1PRBSTestEvent 10 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.49.11 optixRtnE1PRBSDataTypeNum OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the number of parameter types N (N >= 1 and currently N = 2). The data types are described as follows:" ::= { optixRtnE1PRBSTestEvent 11 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.49.12 optixRtnE1PRBSType1 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The data types are as follows: 1: number of bit errors 2: BER (calculated based on the number of bit errors) 3: errored second 4: severely errored second 5: unavailable second 6: background block error" ::= { optixRtnE1PRBSTestEvent 12 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.49.13 optixRtnE1PRBSTestResult1 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the statistics. Each 5-byte string represents the accumulative value for a certain type of statistics data. The first byte indicates the data type and the other four bytes indicate the accumulative value." ::= { optixRtnE1PRBSTestEvent 13 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.49.14 optixRtnE1PRBSType2 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The data types are as follows: 1: number of bit errors 2: BER (calculated based on the number of bit errors) 3: errored second 4: severely errored second 5: unavailable second 6: background block error" ::= { optixRtnE1PRBSTestEvent 14 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.49.15 optixRtnE1PRBSTestResult2 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the statistics. Each 5-byte string represents the accumulative value for a certain type of statistics data. The first byte indicates the data type and the other four bytes indicate the accumulative value." ::= { optixRtnE1PRBSTestEvent 15 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.49.16 optixRtnE1PRBSType3 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The data types are as follows: 1: number of bit errors 2: BER (calculated based on the number of bit errors) 3: errored second 4: severely errored second 5: unavailable second 6: background block error" ::= { optixRtnE1PRBSTestEvent 16 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.49.17 optixRtnE1PRBSTestResult3 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the statistics. Each 5-byte string represents the accumulative value for a certain type of statistics data. The first byte indicates the data type and the other four bytes indicate the accumulative value." ::= { optixRtnE1PRBSTestEvent 17 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.49.19 optixRtnE1PRBSType4 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The data types are as follows: 1: number of bit errors 2: BER (calculated based on the number of bit errors) 3: errored second 4: severely errored second 5: unavailable second 6: background block error" ::= { optixRtnE1PRBSTestEvent 19 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.49.20 optixRtnE1PRBSTestResult4 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the statistics. Each 5-byte string represents the accumulative value for a certain type of statistics data. The first byte indicates the data type and the other four bytes indicate the accumulative value." ::= { optixRtnE1PRBSTestEvent 20 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.49.21 optixRtnE1PRBSType5 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The data types are as follows: 1: number of bit errors 2: BER (calculated based on the number of bit errors) 3: errored second 4: severely errored second 5: unavailable second 6: background block error" ::= { optixRtnE1PRBSTestEvent 21 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.49.22 optixRtnE1PRBSTestResult5 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the statistics. Each 5-byte string represents the accumulative value for a certain type of statistics data. The first byte indicates the data type and the other four bytes indicate the accumulative value." ::= { optixRtnE1PRBSTestEvent 22 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.49.23 optixRtnE1PRBSType6 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The data types are as follows: 1: number of bit errors 2: BER (calculated based on the number of bit errors) 3: errored second 4: severely errored second 5: unavailable second 6: background block error" ::= { optixRtnE1PRBSTestEvent 23 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.49.24 optixRtnE1PRBSTestResult6 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the statistics. Each 5-byte string represents the accumulative value for a certain type of statistics data. The first byte indicates the data type and the other four bytes indicate the accumulative value." ::= { optixRtnE1PRBSTestEvent 24 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.90 optixRptRtnAggergationMemberStateEvent OBJECT IDENTIFIER ::= { optixRtnProtectTrapCommon 90 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.90.1 optixRptRtnMSGroupID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the cascading PLA protection group ID." ::= { optixRptRtnAggergationMemberStateEvent 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.90.2 optixRptRtnMSGroupType OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the main NE ID." ::= { optixRptRtnAggergationMemberStateEvent 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.90.3 optixRptRtnMSBoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the slot ID of the slave unit." ::= { optixRptRtnAggergationMemberStateEvent 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.90.4 optixRptRtnMSSubBoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the subboard ID of the slave unit." ::= { optixRptRtnAggergationMemberStateEvent 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.90.5 optixRptRtnMSPortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the port ID of the slave unit." ::= { optixRptRtnAggergationMemberStateEvent 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.90.6 optixRptRtnMSChannelID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the channel ID of the salve unit." ::= { optixRptRtnAggergationMemberStateEvent 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.90.7 optixRptRtnMSHardState OBJECT-TYPE SYNTAX INTEGER { normal(0), abnormal(1), unknown(-1) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the hardware status of the salve unit. The values: 0: normal 1: abnormal" ::= { optixRptRtnAggergationMemberStateEvent 7 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.90.8 optixRptRtnMSLinkState OBJECT-TYPE SYNTAX INTEGER { normal(0), abnormal(1), unknown(-1) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the link status of the slave unit. The values: 0: normal 1: abnormal" ::= { optixRptRtnAggergationMemberStateEvent 8 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.90.9 optixRptRtnMSMasterSlaveState OBJECT-TYPE SYNTAX INTEGER { slave(0), master(1), unknown(255) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the working status of the main unit. Values: 0: slave port 1: main port" ::= { optixRptRtnAggergationMemberStateEvent 9 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.100 optixRptRtnAggergationMemberPriEvent OBJECT IDENTIFIER ::= { optixRtnProtectTrapCommon 100 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.100.1 optixRptRtnEPLAGroupID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the cascading PLA protection group ID." ::= { optixRptRtnAggergationMemberPriEvent 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.100.2 optixRptRtnEPLAGroupType OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the main NE ID." ::= { optixRptRtnAggergationMemberPriEvent 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.100.3 optixRptRtnEPLABoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the slot ID of the slave unit." ::= { optixRptRtnAggergationMemberPriEvent 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.100.4 optixRptRtnEPLASubBoardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the subboard ID of the slave unit." ::= { optixRptRtnAggergationMemberPriEvent 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.100.5 optixRptRtnEPLAPortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the port ID of the slave unit." ::= { optixRptRtnAggergationMemberPriEvent 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.100.6 optixRptRtnEPLAChannelID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the channel ID of the salve unit." ::= { optixRptRtnAggergationMemberPriEvent 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.100.7 optixRptRtnEPLACfgPri OBJECT-TYPE SYNTAX INTEGER { auto(0), lowpri(1), highpri(2), unknown(255) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the config prority of the slave unit.0: auto; 1: lowPri; 2: highPri 0xff: unknown" ::= { optixRptRtnAggergationMemberPriEvent 7 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.20.100.8 optixRptRtnEPLAWorkPri OBJECT-TYPE SYNTAX INTEGER { auto(0), lowpri(1), highpri(2), unknown(-1) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the scheduling mode of the slave unit. 0: auto; 1: lowPri; 2: highPri 0xff: unknown" ::= { optixRptRtnAggergationMemberPriEvent 8 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.30 optixRtnTrap OBJECT IDENTIFIER ::= { optixRtnIFProtectMgr 30 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.30.10 optixRtnIF1j1PGSwitchTrap NOTIFICATION-TYPE OBJECTS{ optixRptRtn1j1PGID,optixRptRtn1j1PGCurrWorkBoardID,optixRptRtn1j1PGCurrWorkSubCardID,optixRptRtn1j1PGCurrWorkPortID,optixRptRtn1j1PGCurrWorkChannel,optixRptRtn1j1PGMainBoardState,optixRptRtn1j1PGBackupBoardState,optixRptRtn1j1PGSwitchRequest } STATUS current DESCRIPTION "Indicates an IF 1+1 protection group switching event." ::= { optixRtnTrap 10 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.30.20 optixRtnIFNj1PGSwitchTrap NOTIFICATION-TYPE OBJECTS{ optixRptRtnNj1PGID,optixRptRtnNj1Channel,optixRptRtnNj1PGSwitchRequest,optixRptRtnNj1PGSwitchState,optixRptRtnNj1PGProtectedPath,optixRptRtnNj1PGFarNearIndicate,optixRptRtnNj1PGSwitchReason } STATUS current DESCRIPTION "Indicates an IF N+1 protection group switching event." ::= { optixRtnTrap 20 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.30.21 optixRtnIFNj1PGFarNoResponseTrap NOTIFICATION-TYPE OBJECTS{ optixRptRtnNj1PGID,optixRptRtnNj1PGProtectedPath,optixRptRtnNj1PGSwitchRequest } STATUS current DESCRIPTION "Indicates an IF N+1 protection group no far-end response event." ::= { optixRtnTrap 21 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.30.30 optixRtnIFPhyLagPGSwitchTrap NOTIFICATION-TYPE OBJECTS{ optixRptRtnPLAPGID,optixRptRtnPLAPGMainBoardID,optixRptRtnPLAPGMainSubCardID,optixRptRtnPLAPGMainPortID,optixRptRtnPLAPGMainHardStatus,optixRptRtnPLAPGMainLinkStatus,optixRptRtnPLAPGMainWorkStatus,optixRptRtnPLAPGSlavePortNum,optixRptRtnPLAPGSlaveBoardID,optixRptRtnPLAPGSlaveSubCardID,optixRptRtnPLAPGSlavePortID,optixRptRtnPLAPGSlaveHardStatus,optixRptRtnPLAPGSlaveLinkStatus,optixRptRtnPLAPGSlaveWorkStatus } STATUS current DESCRIPTION "Indicates an IF PLA group switching event." ::= { optixRtnTrap 30 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.30.40 optixRtnIFCascading1j1PGSwitchTrap NOTIFICATION-TYPE OBJECTS{ optixRptRtnC1j1PGID,optixRptRtnC1j1PGWorkNEID,optixRptRtnC1j1PGWorkBoardID,optixRptRtnC1j1PGWorkSubCardID,optixRptRtnC1j1PGWorkPortID,optixRptRtnC1j1PGCurrWorkChannel,optixRptRtnC1j1PGWorkBoardState,optixRptRtnC1j1PGProtectBoardState,optixRptRtnC1j1PGSwtichRequest } STATUS current DESCRIPTION "Indicates a cascading IF 1+1 protection group switching event." ::= { optixRtnTrap 40 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.30.41 optixRtnNonCascade1j1PGSwitchTrap NOTIFICATION-TYPE OBJECTS{ optixRtnNonCascade1J1GPID,optixRtnNonCascade1J1BoardID,optixRtnNonCascade1J1SubCardID,optixRtnNonCascade1J1PortID,optixRtnNonCascade1J1DevWorkBoardProperty,optixRtnNonCascade1J1WorkBoardDevState,optixRtnNonCascade1J1ProtBoardDevState,optixRtnNonCascade1J1DevSwtichRequest } STATUS current DESCRIPTION "Indicates a none-cascading IF 1+1 protection group switching event." ::= { optixRtnTrap 41 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.30.43 optixRtnIFBitErrorCodeTestTrap NOTIFICATION-TYPE OBJECTS{ optixRtnIFBECTBoardId,optixRtnIFBECTSubCardId,optixRtnIFBECTPortId,optixRtnIFBECTType,optixRtnIFBECTPathId,optixRtnIFBECTDirection,optixRtnIFBECTMode,optixRtnIFBECTTimeStamp,optixRtnIFBECTStartTime,optixRtnIFBECTCurTime,optixRtnIFBECTProgress,optixRtnIFBECTDataTypeNum,optixRtnIFBECTType1,optixRtnIFBECTTestResult1,optixRtnIFBECTType2,optixRtnIFBECTTestResult2,optixRtnIFBECTType3,optixRtnIFBECTTestResult3,optixRtnIFBECTType4,optixRtnIFBECTTestResult4,optixRtnIFBECTType5,optixRtnIFBECTTestResult5,optixRtnIFBECTType6,optixRtnIFBECTTestResult6 } STATUS current DESCRIPTION "Indicates IF bit errors." ::= { optixRtnTrap 43 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.30.46 optixRtnIFBitOldTestTrap NOTIFICATION-TYPE OBJECTS{ optixRtnBECTBoardId,optixRtnBECTSubCardId,optixRtnBECTPortId,optixRtnBECTTimeStamp,optixRtnBECTErrorNum} STATUS current DESCRIPTION "Indicates IF bit errors." ::= { optixRtnTrap 46 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.30.47 optixRtnIFBitTestTrap NOTIFICATION-TYPE OBJECTS{ optixRtnIFBITTESTBoardId,optixRtnIFBITTESTSubCardId,optixRtnIFBITTESTPortId,optixRtnIFBITTESTMode,optixRtnIFBITTESTTimeStamp,optixRtnIFBITTESTStartTime,optixRtnIFBITTESTCurTime,optixRtnIFBITTESTProgress,optixRtnIFBITTESTDataTypeNum,optixRtnIFBITTESTType1,optixRtnIFBITTESTTestResult1,optixRtnIFBITTESTType2,optixRtnIFBITTESTTestResult2,optixRtnIFBITTESTType3,optixRtnIFBITTESTTestResult3,optixRtnIFBITTESTType4,optixRtnIFBITTESTTestResult4,optixRtnIFBITTESTType5,optixRtnIFBITTESTTestResult5,optixRtnIFBITTESTType6,optixRtnIFBITTESTTestResult6} STATUS current DESCRIPTION "Indicates IF bit errors." ::= { optixRtnTrap 47 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.30.48 optixRtnIFBitErrorCodeExTestTrap NOTIFICATION-TYPE OBJECTS{ optixRtnIFBitEXTestBoardId,optixRtnIFBitEXTestSubCardId,optixRtnIFBitEXTestPortId,optixRtnIFBitEXTestMode,optixRtnIFBitEXTestTimeStamp,optixRtnIFBitEXTestStartTime,optixRtnIFBitEXTestCurTime,optixRtnIFBitEXTestProgress,optixRtnIFBitEXTestDataTypeNum,optixRtnIFBitEXTestType1,optixRtnIFBitEXTestTestResult1,optixRtnIFBitEXTestType2,optixRtnIFBitEXTestTestResult2 } STATUS current DESCRIPTION "Indicates IF bit errors." ::= { optixRtnTrap 48 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.30.49 optixRtnE1PRBSTestTrap NOTIFICATION-TYPE OBJECTS{ optixRtnE1PRBSBoardId,optixRtnE1PRBSSubCardId,optixRtnE1PRBSPortId,optixRtnE1PRBSPathId,optixRtnE1PRBSDirection,optixRtnE1PRBSMode,optixRtnE1PRBSTimeStamp,optixRtnE1PRBSStartTime,optixRtnE1PRBSCurTime,optixRtnE1PRBSProgress,optixRtnE1PRBSDataTypeNum,optixRtnE1PRBSType1,optixRtnE1PRBSTestResult1,optixRtnE1PRBSType2,optixRtnE1PRBSTestResult2,optixRtnE1PRBSType3,optixRtnE1PRBSTestResult3,optixRtnE1PRBSType4,optixRtnE1PRBSTestResult4,optixRtnE1PRBSType5,optixRtnE1PRBSTestResult5,optixRtnE1PRBSType6,optixRtnE1PRBSTestResult6 } STATUS current DESCRIPTION "Indicates result of the E1prbs extension interface." ::= { optixRtnTrap 49 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.30.50 optixRtnIFCascadingPhyLagPGSwitchTrap NOTIFICATION-TYPE OBJECTS{ optixRptRtnCPLAPGID,optixRptRtnCPLAPGMainNEID,optixRptRtnCPLAPGMainBoardID,optixRptRtnCPLAPGMainSubID,optixRptRtnCPLAPGMainPortID,optixRptRtnCPLAPGMainHardStatus,optixRptRtnCPLAPGMainLinkStatus,optixRptRtnCPLAPGMainMSStatus,optixRptRtnCPLAPGSlavePuNum,optixRptRtnCPLAPGPu1NEID,optixRptRtnCPLAPGPu1BoardID,optixRptRtnCPLAPGPu1SubCardID,optixRptRtnCPLAPGPu1PortID,optixRptRtnCPLAPGPu1HardStatus,optixRptRtnCPLAPGPu1LinkStatus,optixRptRtnCPLAPGPu1MSStatus } STATUS current DESCRIPTION "Indicates a cascading PLA group switching event." ::= { optixRtnTrap 50 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.30.60 optixRtnIFCascadingPhyLagPGSwitchTrapExt NOTIFICATION-TYPE OBJECTS{ optixRptRtnCPLAPGID,optixRptRtnCPLAPGMainNEID,optixRptRtnCPLAPGMainBoardID,optixRptRtnCPLAPGMainSubID,optixRptRtnCPLAPGMainPortID,optixRptRtnCPLAPGMainHardStatus,optixRptRtnCPLAPGMainLinkStatus,optixRptRtnCPLAPGMainMSStatus } STATUS current DESCRIPTION "Indicates a cascading PLA group switching event." ::= { optixRtnTrap 60 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.30.90 optixRtnIFPhyAggMemberStateSwitchTrapExt NOTIFICATION-TYPE OBJECTS{ optixRptRtnMSGroupID,optixRptRtnMSGroupType,optixRptRtnMSBoardID,optixRptRtnMSSubBoardID,optixRptRtnMSPortID,optixRptRtnMSChannelID,optixRptRtnMSHardState,optixRptRtnMSLinkState,optixRptRtnMSMasterSlaveState } STATUS current DESCRIPTION "Indicates the member state switching event of a PLA group" ::= { optixRtnTrap 90 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.30.240 optixRtnIFPhyLagPGScheduleModeChangeTrap NOTIFICATION-TYPE OBJECTS{ optixRptRtnPLAPGId,optixRptRtnPLAPGType,optixRptRtnPLAPGCfgMode,optixRptRtnPLAPGWorkMode} STATUS current DESCRIPTION "Indicates an IF PLA group schedule mode change event." ::= { optixRtnTrap 240 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.30.100 optixRtnIFPhyAggMemberPriSwitchTrapExt NOTIFICATION-TYPE OBJECTS{ optixRptRtnEPLAGroupID,optixRptRtnEPLAGroupType,optixRptRtnEPLABoardID,optixRptRtnEPLASubBoardID,optixRptRtnEPLAPortID,optixRptRtnEPLAChannelID,optixRptRtnEPLACfgPri,optixRptRtnEPLAWorkPri } STATUS current DESCRIPTION "Indicates the member priority switching event of a PLA group" ::= { optixRtnTrap 100 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.40 optixRtnCCDPParaMgr OBJECT IDENTIFIER ::= { optixRtnIFProtectMgr 40 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.40.1 optixRtnCCDPTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnCCDPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the CCDP cascading port number table." ::= { optixRtnCCDPParaMgr 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.40.1.1 optixRtnCCDPEntry OBJECT-TYPE SYNTAX OptixRtnCCDPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "CCDP ENTRY" INDEX{ optixRtnBoardID,optixRtnSubCardID,optixRtnPortID } ::= { optixRtnCCDPTable 1 } OptixRtnCCDPEntry ::= SEQUENCE { optixRtnCascadingPortId Unsigned32 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.40.1.1.2 optixRtnCascadingPortId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "CCDP cascading port number" ::= { optixRtnCCDPEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.41 optixRtnDfhParaMgr OBJECT IDENTIFIER ::= { optixRtnIFProtectMgr 41 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.41.1 optixRtnDfhTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnDfhEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the RtnDfhParaMgr" ::= { optixRtnDfhParaMgr 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.41.1.1 optixRtnDfhEntry OBJECT-TYPE SYNTAX OptixRtnDfhEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the Dfh ENTRY" INDEX{ optixRtnBoardID,optixRtnSubCardID,optixRtnPortID } ::= { optixRtnDfhTable 1 } OptixRtnDfhEntry ::= SEQUENCE { optixRtnDfhMode INTEGER, optixRtnDfhEnable INTEGER, optixRtnDfhFreq Unsigned32, optixRtnDfhState INTEGER, optixRtnTddRatio Unsigned32, optixRtnRealTddRatio Unsigned32, optixRtnAllValidFreq OCTET STRING, optixRtnTxFreqRgNum Unsigned32, optixRtnTxFreqRange OCTET STRING, optixRtnRslScanResult OCTET STRING, optixRtnAllTddRatio OCTET STRING, optixRtnActiveRslScan Unsigned32 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.41.1.1.1 optixRtnDfhMode OBJECT-TYPE SYNTAX INTEGER { master(1), slave(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the Dfh mode" ::= { optixRtnDfhEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.41.1.1.2 optixRtnDfhEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the Dfh enable" ::= { optixRtnDfhEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.41.1.1.3 optixRtnDfhFreq OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the Dfh frequency" ::= { optixRtnDfhEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.41.1.1.4 optixRtnDfhState OBJECT-TYPE SYNTAX INTEGER { unlocked(1), locked(2), paused(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the Dfh state" ::= { optixRtnDfhEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.41.1.1.5 optixRtnTddRatio OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the tdd ratio" ::= { optixRtnDfhEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.41.1.1.6 optixRtnRealTddRatio OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the real tdd ratio" ::= { optixRtnDfhEntry 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.41.1.1.7 optixRtnAllValidFreq OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates all valid frequency" ::= { optixRtnDfhEntry 7 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.41.1.1.8 optixRtnTxFreqRgNum OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates num of tx frequency range" ::= { optixRtnDfhEntry 8 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.41.1.1.9 optixRtnTxFreqRange OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates all tx frequency range" ::= { optixRtnDfhEntry 9 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.41.1.1.10 optixRtnRslScanResult OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates all rsl scan result" ::= { optixRtnDfhEntry 10 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.41.1.1.11 optixRtnAllTddRatio OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates all tdd ratio" ::= { optixRtnDfhEntry 11 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.41.1.1.12 optixRtnActiveRslScan OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the conduct active rsl scan" ::= { optixRtnDfhEntry 12 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.270 optixRtnXPICLinkDelayStateTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnXPICLinkDelayStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Describes the state of the LinkDelay Status parameter in an XPIC protection group." ::= { optixRtnIFProtect 270 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.270.1 optixRtnXPICLinkDelayStateEntry OBJECT-TYPE SYNTAX OptixRtnXPICLinkDelayStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicats the protection xpic LinkDelay Status Entry" INDEX{ optixRtnIndex1 } ::= { optixRtnXPICLinkDelayStateTable 1 } OptixRtnXPICLinkDelayStateEntry ::= SEQUENCE { optixRtnXPICLinkDelayState INTEGER } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.270.1.1 optixRtnXPICLinkDelayState OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicats the protection xpic link delay state." ::= { optixRtnXPICLinkDelayStateEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.310 optixRtnDualprotEplaTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnDualprotEplaEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Describes configuration parameters for the working board and protection board in a cascading PLA/EPLA protection group." ::= { optixRtnIFProtect 310 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.310.1 optixRtnDualprotEplaEntry OBJECT-TYPE SYNTAX OptixRtnDualprotEplaEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the parameter entry for a cascading PLA/EPLA protection group." INDEX{ optixRtnDualprotEplaID } ::= { optixRtnDualprotEplaTable 1 } OptixRtnDualprotEplaEntry ::= SEQUENCE { optixRtnDualprotEplaType OPTIXRtnPhyLagPGType, optixRtnDualprotEplaMainSlotID Unsigned32, optixRtnDualprotEplaMainSubCardID Unsigned32, optixRtnDualprotEplaMainPortID Unsigned32, optixRtnDualprotEplaSlaveMemsInfo OCTET STRING, optixRtnDualprotEplaRole OPTIXRtnCascadingPLAPGRoleType, optixRtnDualprotEplaProtectType OPTIXRtnCascadingPhyLagPGProtectTypeExt, optixRtnDualprotEplaLcConMemsInfo OCTET STRING, optixRtnDualprotEplaNbConMemsInfo OCTET STRING, optixRtnDualprotEplaSrvNbsrvMapInfo OCTET STRING, optixRtnDualprotEplaCfgRowStatus RowStatus } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.310.1.1 optixRtnDualprotEplaType OBJECT-TYPE SYNTAX OPTIXRtnPhyLagPGType MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the protection group type. Values: 0: PLA 1: EPLA 2: cascading PLA 3:cascading EPLA" ::= { optixRtnDualprotEplaEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.310.1.2 optixRtnDualprotEplaMainSlotID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the slot ID of the main port." ::= { optixRtnDualprotEplaEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.310.1.3 optixRtnDualprotEplaMainSubCardID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the subboard ID of the main port." ::= { optixRtnDualprotEplaEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.310.1.4 optixRtnDualprotEplaMainPortID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the port number of the main port." ::= { optixRtnDualprotEplaEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.310.1.5 optixRtnDualprotEplaSlaveMemsInfo OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the slave port information of the protection group." ::= { optixRtnDualprotEplaEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.310.1.6 optixRtnDualprotEplaRole OBJECT-TYPE SYNTAX OPTIXRtnCascadingPLAPGRoleType MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the role of the current NE in the protection group. Values: 0: slave NE 1: master NE" ::= { optixRtnDualprotEplaEntry 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.310.1.7 optixRtnDualprotEplaProtectType OBJECT-TYPE SYNTAX OPTIXRtnCascadingPhyLagPGProtectTypeExt MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the protection group type. Values: 0: no protection 1: LAG protection 2: optical splitter protection" ::= { optixRtnDualprotEplaEntry 7 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.310.1.8 optixRtnDualprotEplaLcConMemsInfo OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the local NE information of the protection group." ::= { optixRtnDualprotEplaEntry 8 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.310.1.9 optixRtnDualprotEplaNbConMemsInfo OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the neighbor NE information of the protection group." ::= { optixRtnDualprotEplaEntry 9 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.310.1.10 optixRtnDualprotEplaSrvNbsrvMapInfo OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the cascade port information of the keep-alive cascade PLA service." ::= { optixRtnDualprotEplaEntry 10 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.310.1.50 optixRtnDualprotEplaCfgRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the row status of the protection group." DEFVAL{ active } ::= { optixRtnDualprotEplaEntry 50 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.330 optixRtnEplaBusBandwidthTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnEplaBusBandwidthEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Queries or sets the bus bandwidth of an EPLA member." ::= { optixRtnIFProtect 330 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.330.1 optixRtnEplaBusBandwidthEntry OBJECT-TYPE SYNTAX OptixRtnEplaBusBandwidthEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Queries or sets the bus bandwidth of an EPLA member." INDEX{ optixRtnPhyLagMemPriPGID,optixRtnPhyLagMemBoardId,optixRtnPhyLagMemSubCardId,optixRtnPhyLagMemPortId,optixRtnPhyLagMemChannelId } ::= { optixRtnEplaBusBandwidthTable 1 } OptixRtnEplaBusBandwidthEntry ::= SEQUENCE { optixRtnConfigBusBandwidth Unsigned32, optixRtnCurBusBandwidth Unsigned32, optixRtnMaxBusBandwidth Unsigned32 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.330.1.1 optixRtnConfigBusBandwidth OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the bus bandwidth set by the user." ::= { optixRtnEplaBusBandwidthEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.330.1.2 optixRtnCurBusBandwidth OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Current bus bandwidth." ::= { optixRtnEplaBusBandwidthEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.5.10.330.1.3 optixRtnMaxBusBandwidth OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the maximum bandwidth that can be configured." ::= { optixRtnEplaBusBandwidthEntry 3 } END