-- OPTIX-TCU-BOARD-MIB -- MIB generated by ExcelToMIB tool 1.0 -- -- ================================================================= -- Copyright (C) 2012 by HUAWEI TECHNOLOGIES. All rights reserved -- Description: -- Reference: -- Version: V1.00 -- History: -- ,, -- ================================================================= -- OPTIX-TCU-BOARD-MIB DEFINITIONS ::= BEGIN IMPORTS optixProvisionEqpt FROM OPTIX-OID-MIB OBJECT-GROUP,MODULE-COMPLIANCE FROM SNMPv2-CONF Unsigned32,OBJECT-TYPE,MODULE-IDENTITY FROM SNMPv2-SMI optixLogBoardId,optixLogSubCardId FROM OPTIX-BOARD-MANAGE-MIB ; optixTCUBoard MODULE-IDENTITY LAST-UPDATED "201301221007Z" ORGANIZATION "Huawei Technologies co.,Ltd." CONTACT-INFO "R&D Building Huawei Technologies Co., Ltd. Bantian, Longgang District Shenzhen, P. R. China http://www.huawei.com Zip:518129 E-mail:support@huawei.com" DESCRIPTION "This MIB describes the TCU boardconfigurations." REVISION "201301221007Z" DESCRIPTION "The initial revision of this MIB module." ::={ optixProvisionEqpt 2 } -- 1.3.6.1.4.1.2011.2.25.4.30.2.1 optixTCU OBJECT IDENTIFIER ::= { optixTCUBoard 1 } -- 1.3.6.1.4.1.2011.2.25.4.30.2.1.1 optixTCUTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixTCUEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains basic configuration information of TCU" ::= { optixTCU 1 } -- 1.3.6.1.4.1.2011.2.25.4.30.2.1.1.1 optixTCUEntry OBJECT-TYPE SYNTAX OptixTCUEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry containins basic information of TCU" INDEX{ optixLogBoardId,optixLogSubCardId } ::= { optixTCUTable 1 } OptixTCUEntry ::= SEQUENCE { optixTCUSpeedMode INTEGER, optixTCUHighTh OCTET STRING, optixTCULowTh OCTET STRING, optixTCUInFanSpeed Unsigned32, optixTCUOutFanSpeed Unsigned32, optixTCUBoardTemp OCTET STRING, optixTCUOutTakeTemp OCTET STRING, optixTCUInTakeTemp OCTET STRING, optixTCUInnerFanpara Unsigned32, optixTCUOuterfanpara Unsigned32, optixTCUDiscretePara INTEGER } -- 1.3.6.1.4.1.2011.2.25.4.30.2.1.1.1.1 optixTCUSpeedMode OBJECT-TYPE SYNTAX INTEGER { tempCtrl(0), neDiscretectrl(1), neDutyratioctrl(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter specifies the speed and adjust mode of bid and subbid. 0: tempCtrl, 1: neDiscretectrl, 2: neDutyratioctrl" ::= { optixTCUEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.30.2.1.1.1.2 optixTCUHighTh OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter specifies the high tempth of bid sbid." ::= { optixTCUEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.30.2.1.1.1.3 optixTCULowTh OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter specifies the low tempth of bid sbid." ::= { optixTCUEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.30.2.1.1.1.4 optixTCUInFanSpeed OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter specifies the fan speed of inside. Value range: 0 to 65535." ::= { optixTCUEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.30.2.1.1.1.5 optixTCUOutFanSpeed OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter specifies the fan speed of outside. Value range: 0 to 65535." ::= { optixTCUEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.30.2.1.1.1.6 optixTCUBoardTemp OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter specifies the value of temp control unit." ::= { optixTCUEntry 6 } -- 1.3.6.1.4.1.2011.2.25.4.30.2.1.1.1.7 optixTCUOutTakeTemp OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter specifies the temp value of NE out wind tunnnel." ::= { optixTCUEntry 7 } -- 1.3.6.1.4.1.2011.2.25.4.30.2.1.1.1.8 optixTCUInTakeTemp OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter specifies the temp value of NE in wind tunnnel." ::= { optixTCUEntry 8 } -- 1.3.6.1.4.1.2011.2.25.4.30.2.1.1.1.9 optixTCUInnerFanpara OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the para of inside fan speed. Value range: 20 to 100 and 0." ::= { optixTCUEntry 9 } -- 1.3.6.1.4.1.2011.2.25.4.30.2.1.1.1.10 optixTCUOuterfanpara OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the para of outside fan speed. Value range: 20 to 100 and 0." ::= { optixTCUEntry 10 } -- 1.3.6.1.4.1.2011.2.25.4.30.2.1.1.1.11 optixTCUDiscretePara OBJECT-TYPE SYNTAX INTEGER { highspeed(0), lowspeed(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the para of TCU discrete speed." DEFVAL{ 0 } ::= { optixTCUEntry 11 } -- 1.3.6.1.4.1.2011.2.25.4.30.2.1.2 optixTCUIoalmvalTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixTCUIoalmvalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains basic configuration information of TCU" ::= { optixTCU 2 } -- 1.3.6.1.4.1.2011.2.25.4.30.2.1.2.1 optixTCUIoalmvalEntry OBJECT-TYPE SYNTAX OptixTCUIoalmvalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry containins basic information of TCU" INDEX{ optixLogBoardId,optixLogSubCardId,optixTCUAlmId } ::= { optixTCUIoalmvalTable 1 } OptixTCUIoalmvalEntry ::= SEQUENCE { optixTCUAlmId Unsigned32, optixTCUAlmIoval INTEGER } -- 1.3.6.1.4.1.2011.2.25.4.30.2.1.2.1.1 optixTCUAlmId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "This parameter specifies the TCU index. 0: odcSmokeOver, 1: odcWaterAlm, 2: odcDoorOpen, 3: odcSurgeProtectionFail" ::= { optixTCUIoalmvalEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.30.2.1.2.1.2 optixTCUAlmIoval OBJECT-TYPE SYNTAX INTEGER { high(0), low(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter specifies the temperature value of NE in wind tunnnel. 0: high, 1: low" ::= { optixTCUIoalmvalEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.30.2.1.3 optixTCUFuncTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixTCUFuncEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains the information of TCU functional item configurations." ::= { optixTCU 3 } -- 1.3.6.1.4.1.2011.2.25.4.30.2.1.3.1 optixTCUFuncEntry OBJECT-TYPE SYNTAX OptixTCUFuncEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This entry contains the information of TCU functional items." INDEX{ optixLogBoardId,optixTCUFuncTtem } ::= { optixTCUFuncTable 1 } OptixTCUFuncEntry ::= SEQUENCE { optixTCUFuncTtem INTEGER, optixTCUFuncItemEnable INTEGER } -- 1.3.6.1.4.1.2011.2.25.4.30.2.1.3.1.1 optixTCUFuncTtem OBJECT-TYPE SYNTAX INTEGER { odcSurgeProtectionFail(1), odcSmokeOver(4), odcWaterAlm(5), odcDoorOpen(6) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "This parameter specifies the functional item of TCU. 1: odcSurgeProtectionFail, 4: odcSmokeOver, 5: odcWaterAlm, 6: odcDoorOpen" ::= { optixTCUFuncEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.30.2.1.3.1.2 optixTCUFuncItemEnable OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(0) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter specifies the enable state of TCU functional items. 0: disable, 1: enable" ::= { optixTCUFuncEntry 2 } END