-- OPTIX-EFMOAM-MIB -- MIB generated by ExcelToMIB tool 1.0 -- -- ================================================================= -- Copyright (C) 2012 by HUAWEI TECHNOLOGIES. All rights reserved -- Description: -- Reference: -- Version: V1.00 -- History: -- ,, -- ================================================================= -- OPTIX-EFMOAM-MIB DEFINITIONS ::= BEGIN IMPORTS optixProvisionPtn FROM OPTIX-OID-MIB OBJECT-GROUP,MODULE-COMPLIANCE FROM SNMPv2-CONF Unsigned32,OBJECT-TYPE,MODULE-IDENTITY FROM SNMPv2-SMI optixLogBoardId,optixLogSubCardId FROM OPTIX-BOARD-MANAGE-MIB optixPortId FROM OPTIX-PORT-MANAGE-MIB ; optixEfmoam MODULE-IDENTITY LAST-UPDATED "201204200000Z" ORGANIZATION "Huawei Technologies co.,Ltd." CONTACT-INFO "R&D Building Huawei Technologies Co., Ltd. Bantian, Longgang District Shenzhen, P. R. China http://www.huawei.com Zip:518129 E-mail:support@huawei.com" DESCRIPTION "This mib specifies the 802.3ah configuration information of device" REVISION "201204200000Z" DESCRIPTION "The initial revision of this MIB module1." ::={ optixProvisionPtn 17 } -- 1.3.6.1.4.1.2011.2.25.4.50.17.1 optixEfmoamGroup OBJECT IDENTIFIER ::= { optixEfmoam 1 } -- 1.3.6.1.4.1.2011.2.25.4.50.17.1.1 optixEfmoamTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixEfmoamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table describes the basic configuration information of the Layer 2 802.3ah protocol." ::= { optixEfmoamGroup 1 } -- 1.3.6.1.4.1.2011.2.25.4.50.17.1.1.1 optixEfmoamEntry OBJECT-TYPE SYNTAX OptixEfmoamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This entry describes the basic configuration information of the Layer 2 802.3ah protocol." INDEX{ optixLogBoardId,optixLogSubCardId,optixPortId } ::= { optixEfmoamTable 1 } OptixEfmoamEntry ::= SEQUENCE { optixEfmoamEnable INTEGER, optixEfmoamMode INTEGER, optixEfmoamRsplbEn INTEGER, optixEfmoamLinkevtEn INTEGER, optixEfmoamRMode INTEGER, optixEfmoamMaxPduSize Unsigned32, optixEfmoamLoopStatus INTEGER, optixEfmoamSendStatus INTEGER, optixEfmoamReceiveStatus INTEGER, optixEfmoamLocalDiscoverState INTEGER, optixEfmoamRemoteDiscoverState INTEGER, optixEfmoamErrFrmWin Unsigned32, optixEfmoamErrFrmThr Unsigned32, optixEfmoamErrFrmPerWin Unsigned32, optixEfmoamErrFrmPerThr Unsigned32, optixEfmoamErrFrmSecWin Unsigned32, optixEfmoamErrFrmSecThr Unsigned32, optixEfmoamErrFrmSymWin Unsigned32, optixEfmoamErrFrmSymThr OCTET STRING, optixEfmoamUnidirectional INTEGER, optixEfmoamRmtlbEn INTEGER, optixEfmoamRlinkevtEn INTEGER, optixEfmoamRmtRsplbEn INTEGER } -- 1.3.6.1.4.1.2011.2.25.4.50.17.1.1.1.1 optixEfmoamEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the enable status of the 802.3ah protocol. 0: disable, 1: enable" ::= { optixEfmoamEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.50.17.1.1.1.2 optixEfmoamMode OBJECT-TYPE SYNTAX INTEGER { passive(1), active(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the OAM modeof the 802.3ah protocol. 1: passive, 2: active" ::= { optixEfmoamEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.50.17.1.1.1.3 optixEfmoamRsplbEn OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the capability of the 802.3ah protocol to respond to the remote loopback. 0: disable, 1: enable" ::= { optixEfmoamEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.50.17.1.1.1.4 optixEfmoamLinkevtEn OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether link event reporting is enabled for the 802.3ah protocol. 0: disable, 1: enable" ::= { optixEfmoamEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.50.17.1.1.1.5 optixEfmoamRMode OBJECT-TYPE SYNTAX INTEGER { passive(1), active(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the unidirectional operability of the 802.3ah protocol. 1: passive, 2: active" ::= { optixEfmoamEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.50.17.1.1.1.6 optixEfmoamMaxPduSize OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the maximum OAM packet length of the 802.3ah protocol. Value range: 0 to 65535." ::= { optixEfmoamEntry 6 } -- 1.3.6.1.4.1.2011.2.25.4.50.17.1.1.1.7 optixEfmoamLoopStatus OBJECT-TYPE SYNTAX INTEGER { notLb(0), lclInitiate(1), lclRsp(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the loopback status of the 802.3ah protocol. 0: notLb, 1: lclInitiate, 2: lclRsp" ::= { optixEfmoamEntry 7 } -- 1.3.6.1.4.1.2011.2.25.4.50.17.1.1.1.8 optixEfmoamSendStatus OBJECT-TYPE SYNTAX INTEGER { fwd(1), lb(2), discard(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the transmit status of the 802.3ah protocol. 1: fwd, 2: lb, 3: discard" ::= { optixEfmoamEntry 8 } -- 1.3.6.1.4.1.2011.2.25.4.50.17.1.1.1.9 optixEfmoamReceiveStatus OBJECT-TYPE SYNTAX INTEGER { fwd(1), lb(2), discard(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the receive status of the 802.3ah protocol. 1: fwd, 2: lb, 3: discard" ::= { optixEfmoamEntry 9 } -- 1.3.6.1.4.1.2011.2.25.4.50.17.1.1.1.10 optixEfmoamLocalDiscoverState OBJECT-TYPE SYNTAX INTEGER { fault(1), activeSendLocal(2), passiveWait(3), sendLocalRemote(4), sendLocalRemoteOk(5), sendAny(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the local discovery status of the 802.3ah protocol. 1: fault, 2: activeSendLocal, 3: passiveWait, 4: sendLocalRemote, 5: sendLocalRemoteOk, 6: sendAny" ::= { optixEfmoamEntry 10 } -- 1.3.6.1.4.1.2011.2.25.4.50.17.1.1.1.11 optixEfmoamRemoteDiscoverState OBJECT-TYPE SYNTAX INTEGER { unsatified(0), unfinished(1), finished(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the remote discovery status of the 802.3ah protocol. 0: unsatified, 1: unfinished, 2: finished" ::= { optixEfmoamEntry 11 } -- 1.3.6.1.4.1.2011.2.25.4.50.17.1.1.1.12 optixEfmoamErrFrmWin OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the timewindow for monitoring error frames for the 802.3ah protocol. Value range: 1000 to 60000 (unit: ms). The default value is 1000 and the step length is 100." ::= { optixEfmoamEntry 12 } -- 1.3.6.1.4.1.2011.2.25.4.50.17.1.1.1.13 optixEfmoamErrFrmThr OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the threshold of monitored error frames for the 802.3ah protocol. Value range: 1 to 0xffffffff (unit: frame). The default value is 1 and the step length is 1." ::= { optixEfmoamEntry 13 } -- 1.3.6.1.4.1.2011.2.25.4.50.17.1.1.1.14 optixEfmoamErrFrmPerWin OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the monitoring window for the periodically monitored error frames forthe 802.3ah protocol. Value range: 0 to 0xffffffff." ::= { optixEfmoamEntry 14 } -- 1.3.6.1.4.1.2011.2.25.4.50.17.1.1.1.15 optixEfmoamErrFrmPerThr OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the threshold of periodically monitored error frames for the 802.3ah protocol. Value range: 0 to 0xffffffff." ::= { optixEfmoamEntry 15 } -- 1.3.6.1.4.1.2011.2.25.4.50.17.1.1.1.16 optixEfmoamErrFrmSecWin OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the time range of monitored error frame seconds for the 802.3ah protocol. Value range: 10 to 900 (unit: s). The default value is 60." ::= { optixEfmoamEntry 16 } -- 1.3.6.1.4.1.2011.2.25.4.50.17.1.1.1.17 optixEfmoamErrFrmSecThr OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the threshold of monitored error frame seconds for the 802.3ah protocol. Value range: 1 to 65535 (unit: s)." ::= { optixEfmoamEntry 17 } -- 1.3.6.1.4.1.2011.2.25.4.50.17.1.1.1.18 optixEfmoamErrFrmSymWin OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the monitoring window for monitored error frame signals for the 802.3ah protocol. Value range: 1 to 60 (unit: s)." ::= { optixEfmoamEntry 18 } -- 1.3.6.1.4.1.2011.2.25.4.50.17.1.1.1.19 optixEfmoamErrFrmSymThr OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..24)) MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the threshold of monitored error frame signals for the 802.3ah protocol. Value range: 1 to 0xffffffffffffffff. 64-bit data is in string format." ::= { optixEfmoamEntry 19 } -- 1.3.6.1.4.1.2011.2.25.4.50.17.1.1.1.20 optixEfmoamUnidirectional OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the unidirectional operability of the 802.3ah protocol. 0: disable, 1: enable" ::= { optixEfmoamEntry 20 } -- 1.3.6.1.4.1.2011.2.25.4.50.17.1.1.1.21 optixEfmoamRmtlbEn OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the remote loop back support of the 802.3ah protocol. 0: disable, 1: enable" ::= { optixEfmoamEntry 21 } -- 1.3.6.1.4.1.2011.2.25.4.50.17.1.1.1.22 optixEfmoamRlinkevtEn OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the link event enable of the 802.3ah protocol. 0: disable, 1: enable" ::= { optixEfmoamEntry 22 } -- 1.3.6.1.4.1.2011.2.25.4.50.17.1.1.1.23 optixEfmoamRmtRsplbEn OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the remote capability of the 802.3ah protocol to respond to the loopback. 0: disable, 1: enable" ::= { optixEfmoamEntry 23 } END