-- OPTIX-RTN-CCIC-MGR-MIB -- MIB generated by ExcelToMIB tool 1.0 -- -- ================================================================= -- Copyright (C) 2012 by HUAWEI TECHNOLOGIES. All rights reserved -- Description: -- Reference: -- Version: V1.00 -- History: -- ,, -- ================================================================= -- OPTIX-RTN-CCIC-MGR-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-GROUP,MODULE-COMPLIANCE FROM SNMPv2-CONF Unsigned32,OBJECT-TYPE,MODULE-IDENTITY,Integer32 FROM SNMPv2-SMI TEXTUAL-CONVENTION,RowStatus FROM SNMPv2-TC optixProvisionRtn FROM OPTIX-OID-MIB optixRtnBoardID,optixRtnSubCardID,optixRtnPortID,optixRtnIFPortAcmBandWidth,optixRtnIFPortAcmModulationMode FROM OPTIX-RTN-IFBOARD-ATTRIB-MIB ; optixRtnCcicParaMgr MODULE-IDENTITY LAST-UPDATED "201204160935Z" ORGANIZATION "Huawei Technologies co.,Ltd." CONTACT-INFO "R&D Building Huawei Technologies Co., Ltd. Bantian, Longgang District Shenzhen, P. R. China http://www.huawei.com Zip:518129 E-mail:support@huawei.com" DESCRIPTION "This module is used to configure and query IF board related parameters required in radio link configuration and preventive maintenance, including the IF board modulation mode, bandwidth, AM management, and link identifier." REVISION "201204160935Z" DESCRIPTION "The initial revision of this MIB module1." ::={ optixProvisionRtn 11 } OPTIXRtnCcicModulateModeType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Describes the modulation mode supported by an IF board. Values: 1: QPSK 2: 16QAM 3: 32QAM 4: 64QAM 5: 128QAM 6: 256QAM 7: 512QAM 8: 1024QAM 9: QPSKSTRONG 10: 16QAMSTRONG 11: 512QAMLIGHT 12: 1024QAMLIGHT 13: 2048QAM -1: null" SYNTAX INTEGER { modeQPSK(1), mode16QAM(2), mode32QAM(3), mode64QAM(4), mode128QAM(5), mode256QAM(6), mode512QAM(7), mode1024QAM(8), modeQPSKSTRONG(9), mode16QAMSTRONG(10), mode512QAMLIGHT(11), mode1024QAMLIGHT(12), mode2048QAM(13), modeNULL(-1) } -- 1.3.6.1.4.1.2011.2.25.4.40.11.10 optixRtnCcicGroup OBJECT IDENTIFIER ::= { optixRtnCcicParaMgr 10 } -- 1.3.6.1.4.1.2011.2.25.4.40.11.10.10 optixRtnCcicGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnCcicGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the CCIC work group" ::= { optixRtnCcicGroup 10 } -- 1.3.6.1.4.1.2011.2.25.4.40.11.10.10.1 optixRtnCcicGroupEntry OBJECT-TYPE SYNTAX OptixRtnCcicGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the CCIC work group" INDEX{ optixRtnCcicGroupID } ::= { optixRtnCcicGroupTable 1 } OptixRtnCcicGroupEntry ::= SEQUENCE { optixRtnCcicGroupID Unsigned32, optixRtnCcicGroupType Unsigned32, optixRtnCcicMemberInfo OCTET STRING, optixRtnCcicDelGroup Unsigned32 } -- 1.3.6.1.4.1.2011.2.25.4.40.11.10.10.1.1 optixRtnCcicGroupID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the CCIC work group ID." ::= { optixRtnCcicGroupEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.11.10.10.1.2 optixRtnCcicGroupType OBJECT-TYPE SYNTAX Unsigned32 { hubinner(0), hubcascade(1), tail(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the CCIC work group type" ::= { optixRtnCcicGroupEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.11.10.10.1.3 optixRtnCcicMemberInfo OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the Ccic MemberPara." ::= { optixRtnCcicGroupEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.11.10.10.1.4 optixRtnCcicDelGroup OBJECT-TYPE SYNTAX Unsigned32 { false(0), true(1) } MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates whether to delete configurations of the adjacent NE. 0: false 1: true" ::= { optixRtnCcicGroupEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.11.10.20 optixRtnCcicParaTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnCcicParaEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the CCIC work group" ::= { optixRtnCcicGroup 20 } -- 1.3.6.1.4.1.2011.2.25.4.40.11.10.20.1 optixRtnCcicParaEntry OBJECT-TYPE SYNTAX OptixRtnCcicParaEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the CCIC work group" INDEX{ optixRtnCcicGroupID } ::= { optixRtnCcicParaTable 1 } OptixRtnCcicParaEntry ::= SEQUENCE { optixRtnCcicGroupID Unsigned32, optixRtnCcicBandWidth Unsigned32, optixRtnCcicAmEnableStatus Unsigned32, optixRtnCcicAmBottomMode OPTIXRtnCcicModulateModeType, optixRtnCcicAmPeakMode OPTIXRtnCcicModulateModeType, optixRtnCcicAmManualMode OPTIXRtnCcicModulateModeType, optixRtnCcicOduMaxTxpower Integer32, optixRtnCcicATPCAutoThEnable Unsigned32, optixRtnCcicATPCEnable Unsigned32, optixRtnCcicATPCStep Unsigned32, optixRtnCcicATPCHighThreshold Integer32, optixRtnCcicATPCLowThreshold Integer32, optixRtnCcicOduTRSpacing Unsigned32, optixRtnCcicOduTxFreq Unsigned32, optixRtnCcicOduTxPower Integer32, optixRtnCcicOduWorkState Unsigned32 } -- 1.3.6.1.4.1.2011.2.25.4.40.11.10.20.1.2 optixRtnCcicBandWidth OBJECT-TYPE SYNTAX Unsigned32 { bw3p5M(1), bw7M(2), bw14M(3), bw28M(4), bw40M(5), bw56M(6), bw112M(23) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the channel bandwidth." ::= { optixRtnCcicParaEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.11.10.20.1.3 optixRtnCcicAmEnableStatus OBJECT-TYPE SYNTAX Unsigned32 { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the reverse switching status. Values: 0: disabled 1: enabled." ::= { optixRtnCcicParaEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.11.10.20.1.4 optixRtnCcicAmBottomMode OBJECT-TYPE SYNTAX OPTIXRtnCcicModulateModeType MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the guaranteed-capacity mode." ::= { optixRtnCcicParaEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.11.10.20.1.5 optixRtnCcicAmPeakMode OBJECT-TYPE SYNTAX OPTIXRtnCcicModulateModeType MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the full-capacity mode." ::= { optixRtnCcicParaEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.11.10.20.1.6 optixRtnCcicAmManualMode OBJECT-TYPE SYNTAX OPTIXRtnCcicModulateModeType MAX-ACCESS read-write STATUS current DESCRIPTION "Indicate the manually-specified-capacity mode." ::= { optixRtnCcicParaEntry 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.11.10.20.1.7 optixRtnCcicOduMaxTxpower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the maximum transmit power of an ODU board in an CCIC protection group. When the AM function is disabled, the maximum transmit power in the current mode is returned. When the AM function is enabled, the maximum transmit power in the guaranteed capability modulation mode is returned." ::= { optixRtnCcicParaEntry 7 } -- 1.3.6.1.4.1.2011.2.25.4.40.11.10.20.1.8 optixRtnCcicATPCAutoThEnable OBJECT-TYPE SYNTAX Unsigned32 { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the enable status of the ATPC automatic threshold configuration function in an CCIC protection group. The ATPC function enables the transmit power of a transmitter to automatically trace the change of the RSL at the receive end within the ATPC control range. The equipment automatically uses the preset ATPC upper and lower thresholds based on the working mode of the IF board. When the function is disabled, the manually set ATPC upper and lower thresholds are used. Values: 0: disabled 1: enabled." ::= { optixRtnCcicParaEntry 8 } -- 1.3.6.1.4.1.2011.2.25.4.40.11.10.20.1.9 optixRtnCcicATPCEnable OBJECT-TYPE SYNTAX Unsigned32 { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the enable status of the ATPC function in an CCIC protection group. Values: 0: disabled 1: enabled." ::= { optixRtnCcicParaEntry 9 } -- 1.3.6.1.4.1.2011.2.25.4.40.11.10.20.1.10 optixRtnCcicATPCStep OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the ATPC adjustment step in an CCIC protection group. The parameter refers to every increase or decrease in the ODU transmit power. Value range: 10 to 50" ::= { optixRtnCcicParaEntry 10 } -- 1.3.6.1.4.1.2011.2.25.4.40.11.10.20.1.11 optixRtnCcicATPCHighThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the ATPC adjustment upper threshold in an CCIC protection group. When the receive signal level (RSL) is higher than the threshold, the transmitter automatically adjusts its transmit power. Signed type Value range: -850 to -200 Unit: 0.1 dBm." ::= { optixRtnCcicParaEntry 11 } -- 1.3.6.1.4.1.2011.2.25.4.40.11.10.20.1.12 optixRtnCcicATPCLowThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the ATPC adjustment lower threshold in an CCIC protection group. When the receive signal level (RSL) is lower than the threshold, the transmitter automatically adjusts its transmit power. Signed type Value range: -900 to -250 Unit: 0.1 dBm." ::= { optixRtnCcicParaEntry 12 } -- 1.3.6.1.4.1.2011.2.25.4.40.11.10.20.1.13 optixRtnCcicOduTRSpacing OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the T/R spacing of an ODU board in an CCIC protection group to avoid interference. Unit: kHz." ::= { optixRtnCcicParaEntry 13 } -- 1.3.6.1.4.1.2011.2.25.4.40.11.10.20.1.14 optixRtnCcicOduTxFreq OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the transmission frequency of an ODU board in an CCIC protection group. When frequencies of the transmitter/receiver at both ends match, signals can be received and transmitted successfully. Unit: kHz." ::= { optixRtnCcicParaEntry 14 } -- 1.3.6.1.4.1.2011.2.25.4.40.11.10.20.1.15 optixRtnCcicOduTxPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the transmit power of an ODU board in an CCIC protection group. Signed type Unit: 0.1 dBm Value range: 100 to 350." ::= { optixRtnCcicParaEntry 15 } -- 1.3.6.1.4.1.2011.2.25.4.40.11.10.20.1.16 optixRtnCcicOduWorkState OBJECT-TYPE SYNTAX Unsigned32 { muted(0), unmuted(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the transmission status of the corresponding RF transmitter for an CCIC protection group. Values: 0: muted 1: unmuted." ::= { optixRtnCcicParaEntry 16 } -- 1.3.6.1.4.1.2011.2.25.4.40.11.10.30 optixRtnIFPortAllModeCcicCapacityTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnIFPortAllModeCcicCapacityEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Describes the service capacity supported by an IF board in each mode when the CCIC function is enabled." ::= { optixRtnCcicGroup 30 } -- 1.3.6.1.4.1.2011.2.25.4.40.11.10.30.1 optixRtnIFPortAllModeCcicCapacityEntry OBJECT-TYPE SYNTAX OptixRtnIFPortAllModeCcicCapacityEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the query entry for service capacities of an IF port in each mode when the CCIC function is enabled." INDEX{ optixRtnBoardID,optixRtnSubCardID,optixRtnPortID,optixRtnIFPortAcmBandWidth,optixRtnIFPortAcmModulationMode } ::= { optixRtnIFPortAllModeCcicCapacityTable 1 } OptixRtnIFPortAllModeCcicCapacityEntry ::= SEQUENCE { optixRtnIFPortAmCapacityForCcic Unsigned32, optixRtnIFPortAmMaxE1NumForCcic Unsigned32 } -- 1.3.6.1.4.1.2011.2.25.4.40.11.10.30.1.6 optixRtnIFPortAmCapacityForCcic OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the service capacity supported by a mode when the CCIC function is enabled. Unit: M" ::= { optixRtnIFPortAllModeCcicCapacityEntry 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.11.10.30.1.7 optixRtnIFPortAmMaxE1NumForCcic OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the maximum number of E1s supported by a mode when the CCIC function is enabled." ::= { optixRtnIFPortAllModeCcicCapacityEntry 7 } END