-- OPTIX-SDH-PDHBOARD-MIB -- MIB generated by ExcelToMIB tool 1.0 -- -- ================================================================= -- Copyright (C) 2012 by HUAWEI TECHNOLOGIES. All rights reserved -- Description: -- Reference: -- Version: V1.00 -- History: -- ,, -- ================================================================= -- OPTIX-SDH-PDHBOARD-MIB DEFINITIONS ::= BEGIN IMPORTS optixProvisionSdh FROM OPTIX-OID-MIB OBJECT-GROUP,MODULE-COMPLIANCE FROM SNMPv2-CONF Unsigned32,OBJECT-TYPE,MODULE-IDENTITY,NOTIFICATION-TYPE FROM SNMPv2-SMI optixLogBoardId FROM OPTIX-BOARD-MANAGE-MIB optixPortId FROM OPTIX-PORT-MANAGE-MIB DateAndTime FROM SNMPv2-TC ; optixPdhBoard MODULE-IDENTITY LAST-UPDATED "201204200000Z" ORGANIZATION "Huawei Technologies co.,Ltd." CONTACT-INFO "R&D Building Huawei Technologies Co., Ltd. Bantian, Longgang District Shenzhen, P. R. China http://www.huawei.com Zip:518129 E-mail:support@huawei.com" DESCRIPTION "This MIB describes configurations of tributary board management." REVISION "201204200000Z" DESCRIPTION "The initial revision of this MIB module1." ::={ optixProvisionSdh 44 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1 optixPdhBoardGroup OBJECT IDENTIFIER ::= { optixPdhBoard 1 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.1 optixPdhBoardTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixPdhBoardEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table describes configurations of SDH tributary board management." ::= { optixPdhBoardGroup 1 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.1.1 optixPdhBoardEntry OBJECT-TYPE SYNTAX OptixPdhBoardEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Thisentry describes configurations of SDH tributary board management." INDEX{ optixLogBoardId,optixPortId } ::= { optixPdhBoardTable 1 } OptixPdhBoardEntry ::= SEQUENCE { optixPdhBoardSRJ2Mode Unsigned32, optixPdhBoardSRJ2Value OCTET STRING, optixPdhBoardRJ2Mode Unsigned32, optixPdhBoardRJ2Value OCTET STRING, optixPdhBoardSRV5Value Unsigned32, optixPdhBoardSTV5Value Unsigned32, optixPdhBoardRV5Value Unsigned32, optixPdhBoardUsedFlag INTEGER, optixPdhBoardRetimingClk INTEGER, optixPdhBoardSignalInBalance INTEGER, optixPdhBoardSignalOutBalance INTEGER, optixPdhBoardPayLoadType INTEGER, optixPdhBoardE1Frame INTEGER, optixPdhBoardSTJ2Mode Unsigned32, optixPdhBoardSTJ2Value OCTET STRING, optixPdhBoardPathE1eq INTEGER, optixPdhBoardDefaultBus INTEGER, optixPdhBoardWorkBus INTEGER, optixPdhBoardCodeType INTEGER, optixPdhBdPayloadTypeNew INTEGER } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.1.1.1 optixPdhBoardSRJ2Mode OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the J2 byte to be received mode. 0: single-type mode, 1: 16-type mode" ::= { optixPdhBoardEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.1.1.2 optixPdhBoardSRJ2Value OBJECT-TYPE SYNTAX OCTET STRING(SIZE(0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the value of the J2 byte to be received." ::= { optixPdhBoardEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.1.1.3 optixPdhBoardRJ2Mode OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the received J2 byte mode. Value range: 0 to 63." ::= { optixPdhBoardEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.1.1.4 optixPdhBoardRJ2Value OBJECT-TYPE SYNTAX OCTET STRING(SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the value of the received J2 byte." ::= { optixPdhBoardEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.1.1.5 optixPdhBoardSRV5Value OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the value of theV5 byte to be received. Value range: 0 to 7." ::= { optixPdhBoardEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.1.1.6 optixPdhBoardSTV5Value OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the value of the V5 byte to be transmitted. Value range: 0 to 7." ::= { optixPdhBoardEntry 6 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.1.1.7 optixPdhBoardRV5Value OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the value of the receivedV5 byte. Value range: 0 to 2." ::= { optixPdhBoardEntry 7 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.1.1.8 optixPdhBoardUsedFlag OBJECT-TYPE SYNTAX INTEGER { unuse(0), use(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether the SDH tributary board management channel is used. 0: unuse, 1: use" ::= { optixPdhBoardEntry 8 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.1.1.9 optixPdhBoardRetimingClk OBJECT-TYPE SYNTAX INTEGER { noret(0), liu(1), xc(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the retiming mode. 0: noret, 1: liu, 2: xc" ::= { optixPdhBoardEntry 9 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.1.1.10 optixPdhBoardSignalInBalance OBJECT-TYPE SYNTAX INTEGER { unbalance(0), balance(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the balance of input signals. 0: unbalance, 1: balance" ::= { optixPdhBoardEntry 10 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.1.1.11 optixPdhBoardSignalOutBalance OBJECT-TYPE SYNTAX INTEGER { unbalance(0), balance(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the balance of output signals. 0: unbalance, 1: balance" ::= { optixPdhBoardEntry 11 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.1.1.12 optixPdhBoardPayLoadType OBJECT-TYPE SYNTAX INTEGER { e1(0), t1(1), e3(2), t3(3), e4(4), stm1(5) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicatesthe service type. 0: E1, 1: T1, 2: E3, 3: T3, 4: E4, 5: STM-1" ::= { optixPdhBoardEntry 12 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.1.1.13 optixPdhBoardE1Frame OBJECT-TYPE SYNTAX INTEGER { unframed(0), framed(1), crcFramed(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the E1 frame format. 0: unframed, 1: framed, 2: crcFramed" ::= { optixPdhBoardEntry 13 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.1.1.14 optixPdhBoardSTJ2Mode OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the J2 byte to be transmitted mode. Value range: 0 to 16." ::= { optixPdhBoardEntry 14 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.1.1.15 optixPdhBoardSTJ2Value OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the value of the J2 byte to be transmitted." ::= { optixPdhBoardEntry 15 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.1.1.16 optixPdhBoardPathE1eq OBJECT-TYPE SYNTAX INTEGER { ohm75(1), ohm120(2), ohm100(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the impedance of the SDH tributary board Path. 1: ohm75, 2: ohm120, 4: ohm100" ::= { optixPdhBoardEntry 16 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.1.1.17 optixPdhBoardDefaultBus OBJECT-TYPE SYNTAX INTEGER { a(0), b(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the default bus of the down Path. 0: a, 1: b" ::= { optixPdhBoardEntry 17 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.1.1.18 optixPdhBoardWorkBus OBJECT-TYPE SYNTAX INTEGER { a(0), b(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the work bus of the down Path. 0: a, 1: b" ::= { optixPdhBoardEntry 18 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.1.1.19 optixPdhBoardCodeType OBJECT-TYPE SYNTAX INTEGER { b8zs(0), ami(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the code type of the SDH tributary board Path. 0: b8zs, 1: ami" ::= { optixPdhBoardEntry 19 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.1.1.20 optixPdhBdPayloadTypeNew OBJECT-TYPE SYNTAX INTEGER { e1(0), t1(1), e3(2), t3(3), e4(4), stm1(5) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicatesthe service type. 0: E1, 1: T1, 2: E3, 3: T3, 4: E4, 5: STM-1" ::= { optixPdhBoardEntry 20 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.2 optixPdhBoardBipThTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixPdhBoardBipThEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table describes the configurations of the bit error threshold or deterioration threshold." ::= { optixPdhBoardGroup 2 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.2.1 optixPdhBoardBipThEntry OBJECT-TYPE SYNTAX OptixPdhBoardBipThEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This entry describes the configurations of bit error threshold or deterioration threshold." INDEX{ optixLogBoardId,optixPortId,optixPdhBoardThType } ::= { optixPdhBoardBipThTable 1 } OptixPdhBoardBipThEntry ::= SEQUENCE { optixPdhBoardThType Unsigned32, optixPdhBoardExecTh Unsigned32, optixPdhBoardSdTh Unsigned32 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.2.1.1 optixPdhBoardThType OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the threshold type. 1: B1 threshold, 2: B2 threshold, 3: B3 threshold in VC-4s, 4: B3 threshold in VC-3s, 5: BIP2 threshold, 6: B3-IEC" ::= { optixPdhBoardBipThEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.2.1.2 optixPdhBoardExecTh OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the level of performance threshold-crossing. 1: 1.0E-9, 2: 1.0E-8, 3: 1.0E-7, 4: 1.0E-6, 5: 1.0E-5, 6: 1.0E-4, 7: 1.0E-3. The value range for bip2th: 3 to 7." ::= { optixPdhBoardBipThEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.2.1.3 optixPdhBoardSdTh OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the level of performance deterioration. 1: 1.0E-9, 2: 1.0E-8, 3: 1.0E-7, 4: 1.0E-6, 5: 1.0E-5, 6: 1.0E-4, 7: 1.0E-3. The value range for bip2th: 2 to 6." ::= { optixPdhBoardBipThEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.3 optixPdhBoardInsUneqTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixPdhBoardInsUneqEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table describes configurations of inserted alarm management of the SDH tributary board." ::= { optixPdhBoardGroup 3 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.3.1 optixPdhBoardInsUneqEntry OBJECT-TYPE SYNTAX OptixPdhBoardInsUneqEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Thisentry describes configurations of inserted alarm management of the SDH tributary board." INDEX{ optixLogBoardId,optixPortId,optixPdhBoardEid } ::= { optixPdhBoardInsUneqTable 1 } OptixPdhBoardInsUneqEntry ::= SEQUENCE { optixPdhBoardEid Unsigned32, optixPdhBoardUneqFlag INTEGER } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.3.1.1 optixPdhBoardEid OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the conditions for inserting the UNEQ." ::= { optixPdhBoardInsUneqEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.3.1.2 optixPdhBoardUneqFlag OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether to insert the UNEQ or not. 0: disable, 1: enable" ::= { optixPdhBoardInsUneqEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.4 optixPdhBoardOhTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixPdhBoardOhEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table describes configurations of overhead of the SDH tributary board." ::= { optixPdhBoardGroup 4 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.4.1 optixPdhBoardOhEntry OBJECT-TYPE SYNTAX OptixPdhBoardOhEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Thisentry describes configurations of overhead of the SDH tributary board." INDEX{ optixLogBoardId,optixPortId,optixPdhBoardLeavel,optixPdhBoardOhpos } ::= { optixPdhBoardOhTable 1 } OptixPdhBoardOhEntry ::= SEQUENCE { optixPdhBoardLeavel INTEGER, optixPdhBoardOhpos INTEGER, optixPdhBoardRpoh Unsigned32, optixPdhBoardTpoh Unsigned32 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.4.1.1 optixPdhBoardLeavel OBJECT-TYPE SYNTAX INTEGER { vc4(1), au44c(2), au48c(3), au416c(4), au464c(5), vc12(6), vc3(7), au3(9) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the leavel of the path. 6: vc12, 7: vc3, 1: vc4, 2: au44c, 3: au48c, 4: au416c, 5: au464c, 9: au3" ::= { optixPdhBoardOhEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.4.1.2 optixPdhBoardOhpos OBJECT-TYPE SYNTAX INTEGER { c2(3), g1(4), f2(5), f3(7), k3(8), n1(9), v5(11), n2(13), k4(14) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates overhead pos of the path. 3: C2, 4: G1, 5: F2, 7: F3, 8: K3, 9: N1, 11: V5, 13: N2, 14: K4" ::= { optixPdhBoardOhEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.4.1.3 optixPdhBoardRpoh OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the receiving overhead byte of SDH tributary path board. The byte ranges from 0 to 255" ::= { optixPdhBoardOhEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.4.1.4 optixPdhBoardTpoh OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the sending overhead byte of SDH tributary path board. The byte ranges from 0 to 255" ::= { optixPdhBoardOhEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.5 optixBitTestTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixBitTestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table describes configurations of bit test of the SDH board." ::= { optixPdhBoardGroup 5 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.5.1 optixBitTestEntry OBJECT-TYPE SYNTAX OptixBitTestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This entry describes configurations of bit test of the SDH board." INDEX{ optixLogBoardId,optixBitTestXcLeavel,optixPortId } ::= { optixBitTestTable 1 } OptixBitTestEntry ::= SEQUENCE { optixBitTestXcLeavel Unsigned32, optixBitTestDir INTEGER, optixBitTestMode Unsigned32, optixBitTestStartTime DateAndTime, optixBitTestCurrentcyc Unsigned32, optixBitTestStartcyc Unsigned32, optixBitTestErrNum1 OCTET STRING, optixBitTestErrNum2 OCTET STRING, optixBitTestErrNum3 OCTET STRING, optixBitTestAction INTEGER, optixBitTestTime Unsigned32 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.5.1.1 optixBitTestXcLeavel OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the level of the bit test. 1: vc4, 2: vc3, 3: vc12" ::= { optixBitTestEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.5.1.2 optixBitTestDir OBJECT-TYPE SYNTAX INTEGER { xc(1), liu(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates direction of the bit test. 1: xc, 2: liu" ::= { optixBitTestEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.5.1.3 optixBitTestMode OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates mode of the bit test. 1: short-term test, 2: long-term test, 3: extra-long-term test" ::= { optixBitTestEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.5.1.4 optixBitTestStartTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates start time of the bit test." ::= { optixBitTestEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.5.1.5 optixBitTestCurrentcyc OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates current cycle of the bit test. Value range: 0 to 255." ::= { optixBitTestEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.5.1.6 optixBitTestStartcyc OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates start cycle of the bit test. Value range: 0 to 255." ::= { optixBitTestEntry 6 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.5.1.7 optixBitTestErrNum1 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..1024)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates start cycle number of the bit test(1-93)." ::= { optixBitTestEntry 7 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.5.1.8 optixBitTestErrNum2 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..1024)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates start cycle number of the bit test(94-186)." ::= { optixBitTestEntry 8 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.5.1.9 optixBitTestErrNum3 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..1024)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates start cycle number of the bit test(187-255)." ::= { optixBitTestEntry 9 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.5.1.10 optixBitTestAction OBJECT-TYPE SYNTAX INTEGER { stop(0), start(1), invalid(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object query invalid,be used to start or stop bit test. 0: stop, 1: start, 255: invalid" ::= { optixBitTestEntry 10 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.5.1.11 optixBitTestTime OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object query invalid,be used to set bit test time. Value range: 0 to 255." ::= { optixBitTestEntry 11 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.6 optixBitTestExtTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixBitTestExtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table describes configurations of expand bit test of the SDH board." ::= { optixPdhBoardGroup 6 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.6.1 optixBitTestExtEntry OBJECT-TYPE SYNTAX OptixBitTestExtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This entry describes configurations of expand bit test of the SDH board." INDEX{ optixLogBoardId,optixBitTestXcLeavel,optixPortId,optixBitTestDir,optixBitTestMode,optixBitTestStartTime,optixBitTestEndTime } ::= { optixBitTestExtTable 1 } OptixBitTestExtEntry ::= SEQUENCE { optixBitTestEndTime DateAndTime, optixBitTestProgress Unsigned32, optixBitTestRealTestPeriod Unsigned32 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.6.1.1 optixBitTestEndTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates end time of the bit test." ::= { optixBitTestExtEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.6.1.2 optixBitTestProgress OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates current progress of the bit test. Current progress: 1 to 100." ::= { optixBitTestExtEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.6.1.3 optixBitTestRealTestPeriod OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates real test period of the bit test. Value range: 0 to 255." ::= { optixBitTestExtEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.7 optixBitTestExtTypeNumTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixBitTestExtTypeNumEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table describes configurations of the result of expand bit test of the SDH board." ::= { optixPdhBoardGroup 7 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.7.1 optixBitTestExtTypeNumEntry OBJECT-TYPE SYNTAX OptixBitTestExtTypeNumEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This entry describes configurations of the result of expand bit test of the SDH board." INDEX{ optixLogBoardId,optixBitTestXcLeavel,optixPortId,optixBitTestDir,optixBitTestMode,optixBitTestStartTime,optixBitTestEndTime,optixBitTestTypeNumID } ::= { optixBitTestExtTypeNumTable 1 } OptixBitTestExtTypeNumEntry ::= SEQUENCE { optixBitTestTypeNumID Unsigned32, optixBitTestTypeNumType Unsigned32, optixBitTestTypeNumResult Unsigned32 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.7.1.1 optixBitTestTypeNumID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates type number of the bit test." ::= { optixBitTestExtTypeNumEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.7.1.2 optixBitTestTypeNumType OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates type of the bit test. Value range: 0 to 255." ::= { optixBitTestExtTypeNumEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.7.1.3 optixBitTestTypeNumResult OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates type result of the bit test." ::= { optixBitTestExtTypeNumEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.8 optixStartBitTestExtTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixStartBitTestExtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table describes start or stop expand bit test." ::= { optixPdhBoardGroup 8 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.8.1 optixStartBitTestExtEntry OBJECT-TYPE SYNTAX OptixStartBitTestExtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This entry describes start or stop expand bit test ." INDEX{ optixLogBoardId,optixPortId } ::= { optixStartBitTestExtTable 1 } OptixStartBitTestExtEntry ::= SEQUENCE { optixStartBitTestExtAction INTEGER, optixStartBitTestExtDir INTEGER, optixStartBitTestExtMode Unsigned32, optixStartBitTestExtTime Unsigned32 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.8.1.1 optixStartBitTestExtAction OBJECT-TYPE SYNTAX INTEGER { stop(0), start(1), invalid(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object query invalid,be used to start or stop expand bit test. 0: stop, 1: start, 255: invalid" ::= { optixStartBitTestExtEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.8.1.2 optixStartBitTestExtDir OBJECT-TYPE SYNTAX INTEGER { xc(1), liu(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates direction of the bit test. 1: xc, 2: liu" ::= { optixStartBitTestExtEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.8.1.3 optixStartBitTestExtMode OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates mode of the bit test. 1: short-term test, 2: long-term test, 3: extra-long-term test" ::= { optixStartBitTestExtEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.8.1.4 optixStartBitTestExtTime OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object query invalid,be used to set expand bit test time. Value range: 0 to 255." ::= { optixStartBitTestExtEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.9 optixSdhBitTestEvent OBJECT IDENTIFIER ::= { optixPdhBoardGroup 9 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.9.1 optixSdhBitTest NOTIFICATION-TYPE STATUS current DESCRIPTION "This objectis used to reportthe SDH bit test event." ::= { optixSdhBitTestEvent 1 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.9.2 optixSdhBitTestExt NOTIFICATION-TYPE STATUS current DESCRIPTION "This objectis used to reportthe SDH expand bit test event." ::= { optixSdhBitTestEvent 2 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.10 optixSdhBitTestEventMember OBJECT IDENTIFIER ::= { optixPdhBoardGroup 10 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.10.1 optixSdhBitTestBoardId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This object indicates the board id of the bit test." ::= { optixSdhBitTestEventMember 1 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.10.2 optixSdhBitTestTimeStamp OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This object indicates the Time Stamp of the bit test." ::= { optixSdhBitTestEventMember 2 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.10.3 optixSdhBitTestPortId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This object indicates the port id of the bit test." ::= { optixSdhBitTestEventMember 3 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.10.4 optixSdhBitTestTSlot OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This object indicates the slot id of the bit test." ::= { optixSdhBitTestEventMember 4 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.10.5 optixSdhBitTestErrNum OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This object indicates start cycle number of the bit test." ::= { optixSdhBitTestEventMember 5 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.10.6 optixSdhBitTestLevel OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This object indicates the leavel of the bit test." ::= { optixSdhBitTestEventMember 6 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.10.7 optixSdhBitTestDir OBJECT-TYPE SYNTAX INTEGER { xc(1), liu(2) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This object indicates direction of the bit test." ::= { optixSdhBitTestEventMember 7 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.10.8 optixSdhBitTestMode OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This object indicates mode of the bit test." ::= { optixSdhBitTestEventMember 8 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.10.9 optixSdhBitTestStartTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This object indicates start time of the bit test." ::= { optixSdhBitTestEventMember 9 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.10.10 optixSdhBitTestEndTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This object indicates end time of the bit test." ::= { optixSdhBitTestEventMember 10 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.10.11 optixSdhBitTestProgress OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This object indicates current progress of the bit test." ::= { optixSdhBitTestEventMember 11 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.10.12 optixSdhBitTestTypeNum OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This object indicates type number of the bit test." ::= { optixSdhBitTestEventMember 12 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.10.13 optixSdhBitTestType1 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This object indicates type1 of the bit test." ::= { optixSdhBitTestEventMember 13 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.10.14 optixSdhBitTestTestResult1 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This object indicates type1 result of the bit test." ::= { optixSdhBitTestEventMember 14 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.10.15 optixSdhBitTestType2 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This object indicates type2 of the bit test." ::= { optixSdhBitTestEventMember 15 } -- 1.3.6.1.4.1.2011.2.25.4.10.44.1.10.16 optixSdhBitTestTestResult2 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This object indicates type2 result of the bit test." ::= { optixSdhBitTestEventMember 16 } END