-- OPTIX-SDH-LMSP-MIB -- MIB generated by ExcelToMIB tool 1.0 -- -- ================================================================= -- Copyright (C) 2012 by HUAWEI TECHNOLOGIES. All rights reserved -- Description: -- Reference: -- Version: V1.00 -- History: -- ,, -- ================================================================= -- OPTIX-SDH-LMSP-MIB DEFINITIONS ::= BEGIN IMPORTS optixProvisionSdh FROM OPTIX-OID-MIB OBJECT-GROUP,MODULE-COMPLIANCE FROM SNMPv2-CONF Unsigned32,OBJECT-TYPE,MODULE-IDENTITY,Integer32,NOTIFICATION-TYPE FROM SNMPv2-SMI RowStatus FROM SNMPv2-TC ; optixSdhLmsp MODULE-IDENTITY LAST-UPDATED "201204200000Z" ORGANIZATION "Huawei Technologies co.,Ltd." CONTACT-INFO "R&D Building Huawei Technologies Co., Ltd. Bantian, Longgang District Shenzhen, P. R. China http://www.huawei.com Zip:518129 E-mail:support@huawei.com" DESCRIPTION "This MIB describesLMSP configurations." REVISION "201204200000Z" DESCRIPTION "The initial revision of this MIB module1." ::={ optixProvisionSdh 41 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5 optixSdhLmspGroup OBJECT IDENTIFIER ::= { optixSdhLmsp 5 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1 optixSdhLmspgTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixSdhLmspgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table describes the LMSP group configurations." ::= { optixSdhLmspGroup 1 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1 optixSdhLmspgEntry OBJECT-TYPE SYNTAX OptixSdhLmspgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This entry describes the LMSP group configurations." INDEX{ optixSdhLmspgid } ::= { optixSdhLmspgTable 1 } OptixSdhLmspgEntry ::= SEQUENCE { optixSdhLmspgid Unsigned32, optixSdhLmspProtectType INTEGER, optixSdhLmspWorkChnNum Unsigned32, optixSdhLmspRevertMode INTEGER, optixSdhLmspOpMode INTEGER, optixSdhLmspActiveFlag INTEGER, optixSdhLmspWtrTime Unsigned32, optixSdhLmspSdEnable INTEGER, optixSdhLmspSwitchReq INTEGER, optixSdhLmspSwitchSta INTEGER, optixSdhLmspHoldOffTime Unsigned32, optixSdhLmspK2Mode INTEGER, optixSdhLmspKLevel INTEGER, optixSdhLmspProtocolType INTEGER, optixSdhLmspuid0 Unsigned32, optixSdhLmspBid0 Unsigned32, optixSdhLmspSubid0 Unsigned32, optixSdhLmspPortid0 Unsigned32, optixSdhLmspAu4Map0 OCTET STRING, optixSdhLmspReqSite0 INTEGER, optixSdhLmspuid1 Unsigned32, optixSdhLmspBid1 Unsigned32, optixSdhLmspSubid1 Unsigned32, optixSdhLmspPortid1 Unsigned32, optixSdhLmspAu4Map1 OCTET STRING, optixSdhLmspReqSite1 INTEGER, optixSdhLmspuid2 Unsigned32, optixSdhLmspBid2 Unsigned32, optixSdhLmspSubid2 Unsigned32, optixSdhLmspPortid2 Unsigned32, optixSdhLmspAu4Map2 OCTET STRING, optixSdhLmspReqSite2 INTEGER, optixSdhLmspuid3 Unsigned32, optixSdhLmspBid3 Unsigned32, optixSdhLmspSubid3 Unsigned32, optixSdhLmspPortid3 Unsigned32, optixSdhLmspAu4Map3 OCTET STRING, optixSdhLmspReqSite3 INTEGER, optixSdhLmspuid4 Unsigned32, optixSdhLmspBid4 Unsigned32, optixSdhLmspSubid4 Unsigned32, optixSdhLmspPortid4 Unsigned32, optixSdhLmspAu4Map4 OCTET STRING, optixSdhLmspReqSite4 INTEGER, optixSdhLmspuid5 Unsigned32, optixSdhLmspBid5 Unsigned32, optixSdhLmspSubid5 Unsigned32, optixSdhLmspPortid5 Unsigned32, optixSdhLmspAu4Map5 OCTET STRING, optixSdhLmspReqSite5 INTEGER, optixSdhLmspuid6 Unsigned32, optixSdhLmspBid6 Unsigned32, optixSdhLmspSubid6 Unsigned32, optixSdhLmspPortid6 Unsigned32, optixSdhLmspAu4Map6 OCTET STRING, optixSdhLmspReqSite6 INTEGER, optixSdhLmspuid7 Unsigned32, optixSdhLmspBid7 Unsigned32, optixSdhLmspSubid7 Unsigned32, optixSdhLmspPortid7 Unsigned32, optixSdhLmspAu4Map7 OCTET STRING, optixSdhLmspReqSite7 INTEGER, optixSdhLmspuid8 Unsigned32, optixSdhLmspBid8 Unsigned32, optixSdhLmspSubid8 Unsigned32, optixSdhLmspPortid8 Unsigned32, optixSdhLmspAu4Map8 OCTET STRING, optixSdhLmspReqSite8 INTEGER, optixSdhLmspuid9 Unsigned32, optixSdhLmspBid9 Unsigned32, optixSdhLmspSubid9 Unsigned32, optixSdhLmspPortid9 Unsigned32, optixSdhLmspAu4Map9 OCTET STRING, optixSdhLmspReqSite9 INTEGER, optixSdhLmspuid10 Unsigned32, optixSdhLmspBid10 Unsigned32, optixSdhLmspSubid10 Unsigned32, optixSdhLmspPortid10 Unsigned32, optixSdhLmspAu4Map10 OCTET STRING, optixSdhLmspReqSite10 INTEGER, optixSdhLmspuid11 Unsigned32, optixSdhLmspBid11 Unsigned32, optixSdhLmspSubid11 Unsigned32, optixSdhLmspPortid11 Unsigned32, optixSdhLmspAu4Map11 OCTET STRING, optixSdhLmspReqSite11 INTEGER, optixSdhLmspuid12 Unsigned32, optixSdhLmspBid12 Unsigned32, optixSdhLmspSubid12 Unsigned32, optixSdhLmspPortid12 Unsigned32, optixSdhLmspAu4Map12 OCTET STRING, optixSdhLmspReqSite12 INTEGER, optixSdhLmspuid13 Unsigned32, optixSdhLmspBid13 Unsigned32, optixSdhLmspSubid13 Unsigned32, optixSdhLmspPortid13 Unsigned32, optixSdhLmspAu4Map13 OCTET STRING, optixSdhLmspReqSite13 INTEGER, optixSdhLmspuid14 Unsigned32, optixSdhLmspBid14 Unsigned32, optixSdhLmspSubid14 Unsigned32, optixSdhLmspPortid14 Unsigned32, optixSdhLmspAu4Map14 OCTET STRING, optixSdhLmspReqSite14 INTEGER, optixSdhLmspStartFlag INTEGER, optixSdhLmspgRowStatus RowStatus } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.1 optixSdhLmspgid OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the LMSP group ID." ::= { optixSdhLmspgEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.2 optixSdhLmspProtectType OBJECT-TYPE SYNTAX INTEGER { snmp1j1(0), snmp1pn(1) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the LMSP protection type. 0: 1+1 protection, 1: 1:N protection" ::= { optixSdhLmspgEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.3 optixSdhLmspWorkChnNum OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the number of LMSP working channels. Value range: 1 to 14." ::= { optixSdhLmspgEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.4 optixSdhLmspRevertMode OBJECT-TYPE SYNTAX INTEGER { norvt(0), rvt(1) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the LMSP revertive mode. 0: non-revertive, 1: revertive" ::= { optixSdhLmspgEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.5 optixSdhLmspOpMode OBJECT-TYPE SYNTAX INTEGER { uniend(0), biend(1) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the single-/dual-ended flag of the LMSP group. 0: single-ended, 1: dual-ended" ::= { optixSdhLmspgEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.6 optixSdhLmspActiveFlag OBJECT-TYPE SYNTAX INTEGER { adding(1), deleting(2), active(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the LMSP activation flag. 0x01: to be added, 0x02: to be deleted, 0x03: activiated" ::= { optixSdhLmspgEntry 6 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.7 optixSdhLmspWtrTime OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the WTR time of the LMSP group. Value range: 6 to 720 (unit: s)." ::= { optixSdhLmspgEntry 7 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.8 optixSdhLmspSdEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the enable status of the LMSP SD switching. 0: disable, 1: enable" ::= { optixSdhLmspgEntry 8 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.9 optixSdhLmspSwitchReq OBJECT-TYPE SYNTAX INTEGER { lpsNr(0), lpsDnr(16), lpsExer(64), lpsWtr(96), lpsMs(128), lpsSdLow(160), lpsSd(176), lpsSfLow(192), lpsSf(208), lpsFs(224), lpsLp(240) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the LMSP switching request. 0: lpsNr, 16: lpsDnr, 64: lpsExer, 96: lpsWtr, 128: lpsMs, 160: lpsSdLow, 176: lpsSd, 192: lpsSfLow, 208: lpsSf, 224: lpsFs, 240: lpsLp" ::= { optixSdhLmspgEntry 9 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.10 optixSdhLmspSwitchSta OBJECT-TYPE SYNTAX INTEGER { stop(0), i(1), s(4), starting(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the LMSP switching status. 0: stop(0), 1: i, 4: s, 255: starting" ::= { optixSdhLmspgEntry 10 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.11 optixSdhLmspHoldOffTime OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the LMSP switching delay time. Value range: 0 to 100 (unit: 100 ms). If there is no delay time, the returned value is 0." ::= { optixSdhLmspgEntry 11 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.12 optixSdhLmspK2Mode OBJECT-TYPE SYNTAX INTEGER { noindicate(0), indicate(1) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the last three bits of the K2 byte of the LMSP group, which represents the single-/dual-ended mode. 0: noindicate, 1: indicate" ::= { optixSdhLmspgEntry 12 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.13 optixSdhLmspKLevel OBJECT-TYPE SYNTAX INTEGER { kHigh(0), kLow(1) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the priority level of the SF and SD in the K byte. 0: kHigh, 1: kLow" ::= { optixSdhLmspgEntry 13 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.14 optixSdhLmspProtocolType OBJECT-TYPE SYNTAX INTEGER { old(0), new(1), restruct(2), transoceanic(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the protocol type of the LMSP group. 0: old, 1: new, 2: restruct, 3: transoceanic" ::= { optixSdhLmspgEntry 14 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.15 optixSdhLmspuid0 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the LMSP protection unit ID. Value range for RTN 980: 0 to 7. Value range for RTN 950: 0 to 4." ::= { optixSdhLmspgEntry 15 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.16 optixSdhLmspBid0 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the slot ID of the LMSP group. The value is determined by the line board." ::= { optixSdhLmspgEntry 16 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.17 optixSdhLmspSubid0 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the subboard ID of the LMSP group. The value is determined by the line board." ::= { optixSdhLmspgEntry 17 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.18 optixSdhLmspPortid0 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the port number of the LMSP group. The value is determined by the line board." ::= { optixSdhLmspgEntry 18 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.19 optixSdhLmspAu4Map0 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..32)) MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the LMSP group Au4 mapping." ::= { optixSdhLmspgEntry 19 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.20 optixSdhLmspReqSite0 OBJECT-TYPE SYNTAX INTEGER { near(1), far(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the LMSP remote/local end. 1: near, 2: far" ::= { optixSdhLmspgEntry 20 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.21 optixSdhLmspuid1 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the LMSP protection unit ID. Value range for RTN 980: 0 to 7. Value range for RTN 950: 0 to 4." ::= { optixSdhLmspgEntry 21 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.22 optixSdhLmspBid1 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the slot ID of the LMSP group. The value is determined by the line board." ::= { optixSdhLmspgEntry 22 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.23 optixSdhLmspSubid1 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the subboard ID of the LMSP group. The value is determined by the line board." ::= { optixSdhLmspgEntry 23 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.24 optixSdhLmspPortid1 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the port number of the LMSP group. The value is determined by the line board." ::= { optixSdhLmspgEntry 24 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.25 optixSdhLmspAu4Map1 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..32)) MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the LMSP group Au4 mapping. The value is determined by the line board." ::= { optixSdhLmspgEntry 25 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.26 optixSdhLmspReqSite1 OBJECT-TYPE SYNTAX INTEGER { near(1), far(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the LMSP remote/local end. 1: near, 2: far" ::= { optixSdhLmspgEntry 26 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.27 optixSdhLmspuid2 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the LMSP protection unit ID. Value range for RTN 980: 0 to 7. Value range for RTN 950: 0 to 4." ::= { optixSdhLmspgEntry 27 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.28 optixSdhLmspBid2 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the slot ID of the LMSP group. The value is determined by the line board." ::= { optixSdhLmspgEntry 28 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.29 optixSdhLmspSubid2 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the subboard ID of the LMSP group. The value is determined by the line board." ::= { optixSdhLmspgEntry 29 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.30 optixSdhLmspPortid2 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the port number of the LMSP group. The value is determined by the line board." ::= { optixSdhLmspgEntry 30 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.31 optixSdhLmspAu4Map2 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..32)) MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the LMSP group Au4 mapping. The value is determined by the line board" ::= { optixSdhLmspgEntry 31 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.32 optixSdhLmspReqSite2 OBJECT-TYPE SYNTAX INTEGER { near(1), far(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the LMSP remote/local end. 1: near, 2: far" ::= { optixSdhLmspgEntry 32 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.33 optixSdhLmspuid3 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the LMSP protection unit ID. Value range for RTN 980: 0 to 7. Value range for RTN 950: 0 to 4." ::= { optixSdhLmspgEntry 33 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.34 optixSdhLmspBid3 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the slot ID of the LMSP group. The value is determined by the line board." ::= { optixSdhLmspgEntry 34 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.35 optixSdhLmspSubid3 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the subboard ID of the LMSP group. The value is determined by the line board." ::= { optixSdhLmspgEntry 35 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.36 optixSdhLmspPortid3 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the port number of the LMSP group. The value is determined by the line board." ::= { optixSdhLmspgEntry 36 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.37 optixSdhLmspAu4Map3 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..32)) MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the LMSP group Au4 mapping." ::= { optixSdhLmspgEntry 37 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.38 optixSdhLmspReqSite3 OBJECT-TYPE SYNTAX INTEGER { near(1), far(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the LMSP remote/local end. 1: near, 2: far" ::= { optixSdhLmspgEntry 38 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.39 optixSdhLmspuid4 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the LMSP protection unit ID. Value range for RTN 980: 0 to 7. Value range for RTN 950: 0 to 4." ::= { optixSdhLmspgEntry 39 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.40 optixSdhLmspBid4 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the slot ID of the LMSP group. The value is determined by the line board." ::= { optixSdhLmspgEntry 40 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.41 optixSdhLmspSubid4 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the subboard ID of the LMSP group. The value is determined by the line board." ::= { optixSdhLmspgEntry 41 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.42 optixSdhLmspPortid4 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the port number of the LMSP group. The value is determined by the line board." ::= { optixSdhLmspgEntry 42 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.43 optixSdhLmspAu4Map4 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..32)) MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the LMSP group Au4 mapping." ::= { optixSdhLmspgEntry 43 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.44 optixSdhLmspReqSite4 OBJECT-TYPE SYNTAX INTEGER { near(1), far(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the LMSP remote/local end. 1: near, 2: far" ::= { optixSdhLmspgEntry 44 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.45 optixSdhLmspuid5 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the LMSP protection unit ID. Value range for RTN 980: 0 to 7. Value range for RTN 950: 0 to 4." ::= { optixSdhLmspgEntry 45 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.46 optixSdhLmspBid5 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the slot ID of the LMSP group. The value is determined by the line board." ::= { optixSdhLmspgEntry 46 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.47 optixSdhLmspSubid5 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the subboard ID of the LMSP group. The value is determined by the line board." ::= { optixSdhLmspgEntry 47 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.48 optixSdhLmspPortid5 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the port number of the LMSP group. The value is determined by the line board." ::= { optixSdhLmspgEntry 48 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.49 optixSdhLmspAu4Map5 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..32)) MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the LMSP group Au4 mapping. The value is determined by the line board." ::= { optixSdhLmspgEntry 49 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.50 optixSdhLmspReqSite5 OBJECT-TYPE SYNTAX INTEGER { near(1), far(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the LMSP remote/local end." ::= { optixSdhLmspgEntry 50 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.51 optixSdhLmspuid6 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the LMSP protection unit ID. Value range for RTN 980: 0 to 7. Value range for RTN 950: 0 to 4." ::= { optixSdhLmspgEntry 51 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.52 optixSdhLmspBid6 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the slot ID of the LMSP group. The value is determined by the line board." ::= { optixSdhLmspgEntry 52 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.53 optixSdhLmspSubid6 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the subboard ID of the LMSP group. The value is determined by the line board." ::= { optixSdhLmspgEntry 53 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.54 optixSdhLmspPortid6 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the port number of the LMSP group. The value is determined by the line board." ::= { optixSdhLmspgEntry 54 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.55 optixSdhLmspAu4Map6 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..32)) MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the LMSP group Au4 mapping." ::= { optixSdhLmspgEntry 55 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.56 optixSdhLmspReqSite6 OBJECT-TYPE SYNTAX INTEGER { near(1), far(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the LMSP remote/local end." ::= { optixSdhLmspgEntry 56 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.57 optixSdhLmspuid7 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the LMSP protection unit ID. Value range for RTN 980: 0 to 7. Value range for RTN 950: 0 to 4." ::= { optixSdhLmspgEntry 57 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.58 optixSdhLmspBid7 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the slot ID of the LMSP group. The value is determined by the line board." ::= { optixSdhLmspgEntry 58 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.59 optixSdhLmspSubid7 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the subboard ID of the LMSP group. The value is determined by the line board." ::= { optixSdhLmspgEntry 59 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.60 optixSdhLmspPortid7 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the port number of the LMSP group. The value is determined by the line board." ::= { optixSdhLmspgEntry 60 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.61 optixSdhLmspAu4Map7 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..32)) MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the LMSP group Au4 mapping." ::= { optixSdhLmspgEntry 61 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.62 optixSdhLmspReqSite7 OBJECT-TYPE SYNTAX INTEGER { near(1), far(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the LMSP remote/local end." ::= { optixSdhLmspgEntry 62 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.63 optixSdhLmspuid8 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the LMSP protection unit ID. Value range for RTN 980: 0 to 7. Value range for RTN 950: 0 to 4." ::= { optixSdhLmspgEntry 63 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.64 optixSdhLmspBid8 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the slot ID of the LMSP group. The value is determined by the line board." ::= { optixSdhLmspgEntry 64 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.65 optixSdhLmspSubid8 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the subboard ID of the LMSP group. The value is determined by the line board." ::= { optixSdhLmspgEntry 65 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.66 optixSdhLmspPortid8 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the port number of the LMSP group. The value is determined by the line board." ::= { optixSdhLmspgEntry 66 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.67 optixSdhLmspAu4Map8 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..32)) MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the LMSP group Au4 mapping." ::= { optixSdhLmspgEntry 67 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.68 optixSdhLmspReqSite8 OBJECT-TYPE SYNTAX INTEGER { near(1), far(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the LMSP remote/local end." ::= { optixSdhLmspgEntry 68 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.69 optixSdhLmspuid9 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the LMSP protection unit ID. Value range for RTN 980: 0 to 7. Value range for RTN 950: 0 to 4." ::= { optixSdhLmspgEntry 69 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.70 optixSdhLmspBid9 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the slot ID of the LMSP group. The value is determined by the line board." ::= { optixSdhLmspgEntry 70 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.71 optixSdhLmspSubid9 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the subboard ID of the LMSP group. The value is determined by the line board." ::= { optixSdhLmspgEntry 71 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.72 optixSdhLmspPortid9 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the port number of the LMSP group. The value is determined by the line board." ::= { optixSdhLmspgEntry 72 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.73 optixSdhLmspAu4Map9 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..32)) MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the LMSP group Au4 mapping." ::= { optixSdhLmspgEntry 73 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.74 optixSdhLmspReqSite9 OBJECT-TYPE SYNTAX INTEGER { near(1), far(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the LMSP remote/local end. 1: near, 2: far" ::= { optixSdhLmspgEntry 74 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.75 optixSdhLmspuid10 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the LMSP protection unit ID. Value range for RTN 980: 0 to 7. Value range for RTN 950: 0 to 4." ::= { optixSdhLmspgEntry 75 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.76 optixSdhLmspBid10 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the slot ID of the LMSP group. The value is determined by the line board." ::= { optixSdhLmspgEntry 76 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.77 optixSdhLmspSubid10 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the subboard ID of the LMSP group. The value is determined by the line board." ::= { optixSdhLmspgEntry 77 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.78 optixSdhLmspPortid10 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the port number of the LMSP group. The value is determined by the line board." ::= { optixSdhLmspgEntry 78 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.79 optixSdhLmspAu4Map10 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..32)) MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the LMSP group Au4 mapping." ::= { optixSdhLmspgEntry 79 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.80 optixSdhLmspReqSite10 OBJECT-TYPE SYNTAX INTEGER { near(1), far(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the LMSP remote/local end. 1: near, 2: far" ::= { optixSdhLmspgEntry 80 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.81 optixSdhLmspuid11 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the LMSP protection unit ID. Value range for RTN 980: 0 to 7. Value range for RTN 950: 0 to 4." ::= { optixSdhLmspgEntry 81 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.82 optixSdhLmspBid11 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the slot ID of the LMSP group. The value is determined by the line board." ::= { optixSdhLmspgEntry 82 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.83 optixSdhLmspSubid11 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the subboard ID of the LMSP group. The value is determined by the line board." ::= { optixSdhLmspgEntry 83 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.84 optixSdhLmspPortid11 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the port number of the LMSP group. The value is determined by the line board." ::= { optixSdhLmspgEntry 84 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.85 optixSdhLmspAu4Map11 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..32)) MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the LMSP group Au4 mapping." ::= { optixSdhLmspgEntry 85 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.86 optixSdhLmspReqSite11 OBJECT-TYPE SYNTAX INTEGER { near(1), far(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the LMSP remote/local end. 1: near, 2: far" ::= { optixSdhLmspgEntry 86 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.87 optixSdhLmspuid12 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the LMSP protection unit ID. Value range for RTN 980: 0 to 7. Value range for RTN 950: 0 to 4." ::= { optixSdhLmspgEntry 87 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.88 optixSdhLmspBid12 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the slot ID of the LMSP group. The value is determined by the line board." ::= { optixSdhLmspgEntry 88 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.89 optixSdhLmspSubid12 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the subboard ID of the LMSP group. The value is determined by the line board." ::= { optixSdhLmspgEntry 89 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.90 optixSdhLmspPortid12 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the port number of the LMSP group. The value is determined by the line board." ::= { optixSdhLmspgEntry 90 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.91 optixSdhLmspAu4Map12 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..32)) MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the LMSP group Au4 mapping." ::= { optixSdhLmspgEntry 91 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.92 optixSdhLmspReqSite12 OBJECT-TYPE SYNTAX INTEGER { near(1), far(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the LMSP remote/local end. 1: near, 2: far" ::= { optixSdhLmspgEntry 92 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.93 optixSdhLmspuid13 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the LMSP protection unit ID. Value range for RTN 980: 0 to 7. Value range for RTN 950: 0 to 4." ::= { optixSdhLmspgEntry 93 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.94 optixSdhLmspBid13 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the slot ID of the LMSP group. The value is determined by the line board." ::= { optixSdhLmspgEntry 94 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.95 optixSdhLmspSubid13 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the subboard ID of the LMSP group. The value is determined by the line board." ::= { optixSdhLmspgEntry 95 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.96 optixSdhLmspPortid13 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the port number of the LMSP group. The value is determined by the line board." ::= { optixSdhLmspgEntry 96 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.97 optixSdhLmspAu4Map13 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..32)) MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the LMSP group Au4 mapping." ::= { optixSdhLmspgEntry 97 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.98 optixSdhLmspReqSite13 OBJECT-TYPE SYNTAX INTEGER { near(1), far(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the LMSP remote/local end. 1: near, 2: far" ::= { optixSdhLmspgEntry 98 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.99 optixSdhLmspuid14 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the LMSP protection unit ID. Value range for RTN 980: 0 to 7. Value range for RTN 950: 0 to 4." ::= { optixSdhLmspgEntry 99 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.100 optixSdhLmspBid14 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the slot ID of the LMSP group. The value is determined by the line board." ::= { optixSdhLmspgEntry 100 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.101 optixSdhLmspSubid14 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the subboard ID of the LMSP group. The value is determined by the line board." ::= { optixSdhLmspgEntry 101 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.102 optixSdhLmspPortid14 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the port number of the LMSP group. The value is determined by the line board." ::= { optixSdhLmspgEntry 102 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.103 optixSdhLmspAu4Map14 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..32)) MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the LMSP group Au4 mapping." ::= { optixSdhLmspgEntry 103 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.104 optixSdhLmspReqSite14 OBJECT-TYPE SYNTAX INTEGER { near(1), far(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the LMSP remote/local end. 1: near, 2: far" ::= { optixSdhLmspgEntry 104 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.105 optixSdhLmspStartFlag OBJECT-TYPE SYNTAX INTEGER { protocolStop(0), protocolStart(1) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the start flag of the LMSP group. 0: protocolStop, 1: protocolStart" ::= { optixSdhLmspgEntry 105 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.1.1.255 optixSdhLmspgRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the row status of the LMSP group." ::= { optixSdhLmspgEntry 255 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.2 optixSdhLmspuTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixSdhLmspuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table describes the configurations of LMSP protocol units." ::= { optixSdhLmspGroup 2 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.2.1 optixSdhLmspuEntry OBJECT-TYPE SYNTAX OptixSdhLmspuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This entry describes the configurations of LMSP units" INDEX{ optixSdhLmspgid,optixSdhLmspuid } ::= { optixSdhLmspuTable 1 } OptixSdhLmspuEntry ::= SEQUENCE { optixSdhLmspuid Unsigned32, optixSdhLmspuExtSwitchCmd INTEGER, optixSdhLmspuSwitchRequest INTEGER, optixSdhLmspuSwitchState INTEGER } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.2.1.1 optixSdhLmspuid OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the ID of LMSP unit" ::= { optixSdhLmspuEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.2.1.2 optixSdhLmspuExtSwitchCmd OBJECT-TYPE SYNTAX INTEGER { lmsInvalid(0), lmsExer(4), lmsLockwork(5), lmsMan(8), lmsForce(14), lmsLock(15), lmsClearall(16), lmsExerclr(20), lmsUnlockwork(21), lmsClearwtr(22), lmsManclr(24), lmsForceclr(30), lmsUnlock(31) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the external switching cmd of protocol unit ID. 15: lmsLock, 31: lmsUnlock, 14: lmsForce, 30: lmsForceclr, 8: lmsMan, 24: lmsManclr, 4: lmsExer, 20: lmsExerclr, 16: lmsClearall, 22: lmsClearwtr, 5: lmsLockwork, 21: lmsUnlockwork, 0: lmsInvalid" ::= { optixSdhLmspuEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.2.1.3 optixSdhLmspuSwitchRequest OBJECT-TYPE SYNTAX INTEGER { lpsNr(0), lpsDnr(16), lpsExer(64), lpsWtr(96), lpsMs(128), lpsSdLow(160), lpsSd(176), lpsSfLow(192), lpsSf(208), lpsFs(224), lpsLp(240) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the switching request of protocol unit ID. 0: lpsNr, 16: lpsDnr, 64: lpsExer, 96: lpsWtr, 128: lpsMs, 160: lpsSdLow, 176: lpsSd, 192: lpsSfLow, 208: lpsSf, 224: lpsFs, 240: lpsLp" ::= { optixSdhLmspuEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.2.1.4 optixSdhLmspuSwitchState OBJECT-TYPE SYNTAX INTEGER { stop(0), i(1), s(4), starting(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the LMSP switching status of protocol unit ID. 0: stop(0), 1: i, 4: s, 255: starting" ::= { optixSdhLmspuEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.5 optixSdhLmspSWITCHEventMember OBJECT IDENTIFIER ::= { optixSdhLmspGroup 5 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.5.1 optixSdhLmspgidevt OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This parameter specifies LMSP id" ::= { optixSdhLmspSWITCHEventMember 1 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.5.2 optixSdhLmspuidevt OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This parameter specifies LMSP unit id" ::= { optixSdhLmspSWITCHEventMember 2 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.5.3 optixSdhLmspSwitchReqevt OBJECT-TYPE SYNTAX INTEGER { lpsNr(0), lpsDnr(16), lpsExer(64), lpsWtr(96), lpsMs(128), lpsSdLow(160), lpsSd(176), lpsSfLow(192), lpsSf(208), lpsFs(224), lpsLp(240) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This parameter specifies LMSP switch request" ::= { optixSdhLmspSWITCHEventMember 3 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.5.4 optixSdhLmspSwitchStaevt OBJECT-TYPE SYNTAX INTEGER { stop(0), i(1), s(4), starting(255) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This parameter specifies LMSP switch state" ::= { optixSdhLmspSWITCHEventMember 4 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.5.5 optixSdhLmspSwitchCmd OBJECT-TYPE SYNTAX INTEGER { lmsLock(15), lmsUnlock(31), lmsForce(14), lmsForceClr(30), lmsMan(8), lmsManClr(24), lmsExer(4), lmsExerClr(20), lmsClearAll(16), lmsClearWtr(22) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This parameter indicates the LMSP protection switch command." ::= { optixSdhLmspSWITCHEventMember 5 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.5.6 optixSdhLmspProtPuId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This parameter indicates the unit protected by LMSP." ::= { optixSdhLmspSWITCHEventMember 6 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.5.7 optixSdhLmspLrIndi OBJECT-TYPE SYNTAX INTEGER { na(0), local(1), remote(2) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This parameter indicates the indication of LMSP remote-end or local-end." ::= { optixSdhLmspSWITCHEventMember 7 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.5.8 optixSdhLmspSwitchReason OBJECT-TYPE SYNTAX INTEGER { localReq(1), extReq(2), kReq(3), expireOfTimer(4) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This parameter indicates the reason for LMSP switch." ::= { optixSdhLmspSWITCHEventMember 8 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.6 optixSdhLmspSWITCHEvent OBJECT IDENTIFIER ::= { optixSdhLmspGroup 6 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.6.1 optixSdhLmspSWITCH NOTIFICATION-TYPE OBJECTS{ optixSdhLmspgidevt,optixSdhLmspuidevt,optixSdhLmspSwitchReqevt,optixSdhLmspSwitchStaevt } STATUS current DESCRIPTION "This parameter specifies LMSP switch Event info" ::= { optixSdhLmspSWITCHEvent 1 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.6.2 optixSdhLmspSWITCHCmdUnexe NOTIFICATION-TYPE OBJECTS{ optixSdhLmspgidevt,optixSdhLmspSwitchCmd,optixSdhLmspuidevt } STATUS current DESCRIPTION "This patameter indicates no response of the LMSP remote end" ::= { optixSdhLmspSWITCHEvent 2 } -- 1.3.6.1.4.1.2011.2.25.4.10.41.5.6.3 optixSdhLmspSwitchStateEvent NOTIFICATION-TYPE OBJECTS{ optixSdhLmspgidevt,optixSdhLmspuidevt,optixSdhLmspSwitchReqevt,optixSdhLmspSwitchStaevt,optixSdhLmspProtPuId,optixSdhLmspLrIndi,optixSdhLmspSwitchReason } STATUS current DESCRIPTION "This parameter indicates LMSP switch state event." ::= { optixSdhLmspSWITCHEvent 3 } END