-- OPTIX-RTN-ATPC-MGR-MIB -- MIB generated by ExcelToMIB tool 1.0 -- -- ================================================================= -- Copyright (C) 2012 by HUAWEI TECHNOLOGIES. All rights reserved -- Description: -- Reference: -- Version: V1.00 -- History: -- ,, -- ================================================================= -- OPTIX-RTN-ATPC-MGR-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-GROUP,MODULE-COMPLIANCE FROM SNMPv2-CONF Integer32,Unsigned32,OBJECT-TYPE,MODULE-IDENTITY FROM SNMPv2-SMI optixProvisionRtn FROM OPTIX-OID-MIB OPTIXRtnEnableStateType FROM OPTIX-RTN-GENNERAL-MIB optixRtnBoardID,optixRtnSubCardID,optixRtnPortID FROM OPTIX-RTN-IFBOARD-ATTRIB-MIB ; optixRtnATPCMgr MODULE-IDENTITY LAST-UPDATED "201204160000Z" ORGANIZATION "Huawei Technologies co.,Ltd." CONTACT-INFO "R&D Building Huawei Technologies Co., Ltd. Bantian, Longgang District Shenzhen, P. R. China http://www.huawei.com Zip:518129 E-mail:support@huawei.com" DESCRIPTION "This module is used to configure and query parameters for the ATPC function of IF boards, including the ATPC status, step, and threshold." REVISION "201204160000Z" DESCRIPTION "The initial revision of this MIB module1." ::={ optixProvisionRtn 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.1.10 optixISBoardATPCParameter OBJECT IDENTIFIER ::= { optixRtnATPCMgr 10 } -- 1.3.6.1.4.1.2011.2.25.4.40.1.10.1 optixRtnIFATPCParameterTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnIFATPCParameterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Describes the ATPC attributes of an IF board, including the ATPC adjustment step and thresholds." ::= { optixISBoardATPCParameter 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.1.10.1.1 optixRtnIFATPCParameterEntry OBJECT-TYPE SYNTAX OptixRtnIFATPCParameterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the ATPC attribute entry for an IF board." INDEX{ optixRtnBoardID,optixRtnSubCardID,optixRtnPortID } ::= { optixRtnIFATPCParameterTable 1 } OptixRtnIFATPCParameterEntry ::= SEQUENCE { optixRtnIFATPCEnableState OPTIXRtnEnableStateType, optixRtnIFATPCStep Unsigned32, optixRtnIFATPCHighThreshold Integer32, optixRtnIFATPCLowThreshold Integer32, optixRtnIFATPCAutoThEnableState OPTIXRtnEnableStateType, optixRtnIFATPCCurrHighThreshold Integer32, optixRtnIFATPCCurrLowThreshold Integer32, optixRtnIFATPCAutoThInfo OCTET STRING } -- 1.3.6.1.4.1.2011.2.25.4.40.1.10.1.1.1 optixRtnIFATPCEnableState OBJECT-TYPE SYNTAX OPTIXRtnEnableStateType MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates whether the ATPC function is enabled. Values: 0: disabled 1: enabled" DEFVAL{ 0 } ::= { optixRtnIFATPCParameterEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.1.10.1.1.2 optixRtnIFATPCStep OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the ATPC adjustment step. The parameter refers to every increase or decrease in the ODU transmit power. Value range: 10 to 50" DEFVAL{ 20 } ::= { optixRtnIFATPCParameterEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.1.10.1.1.3 optixRtnIFATPCHighThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the ATPC adjustment upper threshold. When the received signal level (RSL) exceeds the upper threshold, the transmitter automatically adjusts its transmit power. Signed type Value range: -850 to -200 Unit: 0.1 dBm" DEFVAL{ -450 } ::= { optixRtnIFATPCParameterEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.1.10.1.1.4 optixRtnIFATPCLowThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the ATPC adjustment lower threshold. When the RSL is less than the lower threshold, the transmitter automatically adjusts its transmit power. Signed int type Value range: -900.0 to -250.0 Unit: 0.1 dBm" DEFVAL{ -700 } ::= { optixRtnIFATPCParameterEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.1.10.1.1.5 optixRtnIFATPCAutoThEnableState OBJECT-TYPE SYNTAX OPTIXRtnEnableStateType MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates whether ATPC automatic threshold configuration is enabled. The ATPC function enables the transmit power of a transmitter to automatically trace the change of the RSL at the receive end within the ATPC control range. When the function is enabled, the manually set ATPC upper and lower thresholds are invalid. The equipment automatically uses the preset ATPC upper and lower thresholds based on the working mode of the IF board. When the function is disabled, the manually set ATPC upper and lower thresholds are used. Values: 0: disabled 1: enabled" DEFVAL{ 0 } ::= { optixRtnIFATPCParameterEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.1.10.1.1.6 optixRtnIFATPCCurrHighThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the ATPC automatic upper threshold. Signed int type Value range: -900.0 to -250.0 Unit: 0.1 dBm" ::= { optixRtnIFATPCParameterEntry 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.1.10.1.1.7 optixRtnIFATPCCurrLowThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the ATPC automatic lower threshold. Signed int type Value range: -900.0 to -250.0 Unit: 0.1 dBm" ::= { optixRtnIFATPCParameterEntry 7 } -- 1.3.6.1.4.1.2011.2.25.4.40.1.10.1.1.8 optixRtnIFATPCAutoThInfo OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates cascading port information of ATPC Auto Threshold" ::= { optixRtnIFATPCParameterEntry 8 } -- 1.3.6.1.4.1.2011.2.25.4.40.1.10.2 optixRtnIFATPCHistoryParameterTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnIFATPCHistoryParameterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Describes the ATPC attributes of an IF board, including the ATPC adjustment step and thresholds." ::= { optixISBoardATPCParameter 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.1.10.2.1 optixRtnIFATPCHistoryParameterEntry OBJECT-TYPE SYNTAX OptixRtnIFATPCHistoryParameterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the ATPC attribute entry for an IF board." INDEX{ optixRtnBoardID,optixRtnSubCardID,optixRtnPortID } ::= { optixRtnIFATPCHistoryParameterTable 1 } OptixRtnIFATPCHistoryParameterEntry ::= SEQUENCE { optixRtnIFATPCHistoryEventId Unsigned32, optixRtnIFATPCHistoryTime OCTET STRING, optixRtnIFATPCHistoryDirection INTEGER, optixRtnIFATPCHistoryType INTEGER, optixRtnIFATPCHistoryTxPower Integer32, optixRtnIFATPCHistoryRxPower Integer32 } -- 1.3.6.1.4.1.2011.2.25.4.40.1.10.2.1.4 optixRtnIFATPCHistoryEventId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates whether the ATPC function is enabled. Values: 0: disabled 1: enabled" DEFVAL{ 0 } ::= { optixRtnIFATPCHistoryParameterEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.1.10.2.1.5 optixRtnIFATPCHistoryTime OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the ATPC adjustment history" ::= { optixRtnIFATPCHistoryParameterEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.1.10.2.1.6 optixRtnIFATPCHistoryDirection OBJECT-TYPE SYNTAX INTEGER { positive(0), negative(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the ATPC adjustment direction. Values: 0-increment, 1-decrement" DEFVAL{ 7 } ::= { optixRtnIFATPCHistoryParameterEntry 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.1.10.2.1.7 optixRtnIFATPCHistoryType OBJECT-TYPE SYNTAX INTEGER { require(1), response(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the ATPC adjustment action. Values: 1-request, 2-respond" DEFVAL{ 8 } ::= { optixRtnIFATPCHistoryParameterEntry 7 } -- 1.3.6.1.4.1.2011.2.25.4.40.1.10.2.1.8 optixRtnIFATPCHistoryTxPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the ATPC transmit power (a signed number in the unit of 0.1 dBm)." DEFVAL{ 9 } ::= { optixRtnIFATPCHistoryParameterEntry 8 } -- 1.3.6.1.4.1.2011.2.25.4.40.1.10.2.1.9 optixRtnIFATPCHistoryRxPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the ATPC receive power." DEFVAL{ 10 } ::= { optixRtnIFATPCHistoryParameterEntry 9 } END