-- OPTIX-GLOBAL-PER-TIME-MIB -- MIB generated by ExcelToMIB tool 1.0 -- -- ================================================================= -- Copyright (C) 2012 by HUAWEI TECHNOLOGIES. All rights reserved -- Description:This MIB describes the Performance interface of Huawei microwave transmit -- Reference: -- Version: V1.00 -- History: -- ,, -- ================================================================= -- OPTIX-GLOBAL-PER-TIME-MIB DEFINITIONS ::= BEGIN IMPORTS optixCommonGlobal FROM OPTIX-OID-MIB PerformanceEventType,ValidflagType FROM OPTIX-GLOBAL-TC-MIB OBJECT-GROUP,MODULE-COMPLIANCE FROM SNMPv2-CONF Integer32,Unsigned32,OBJECT-TYPE,MODULE-IDENTITY FROM SNMPv2-SMI DateAndTime,DisplayString FROM SNMPv2-TC ; optixGlobalPER MODULE-IDENTITY LAST-UPDATED "200805240500Z" ORGANIZATION "Huawei Technologies co.,Ltd." CONTACT-INFO "R&D Building Huawei Technologies Co., Ltd. Bantian, Longgang District Shenzhen, P. R. China http://www.huawei.com Zip:518129 E-mail:support@huawei.com" DESCRIPTION "SDH performance module" REVISION "200805240500Z" DESCRIPTION "The initial version" ::={ optixCommonGlobal 20 } -- 1.3.6.1.4.1.2011.2.25.3.40.20.10 perMonitorTime OBJECT IDENTIFIER ::= { optixGlobalPER 10 } -- 1.3.6.1.4.1.2011.2.25.3.40.20.10.10 per15mMonitorTime OBJECT IDENTIFIER ::= { perMonitorTime 10 } -- 1.3.6.1.4.1.2011.2.25.3.40.20.10.10.10 per15mMonitorStartTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the start time and date of the 15-minute PM period. When the system is at this time, the 15-minute PM period monitoring starts. The start date and time of the 15-minute PM period cannot be set to be earlier than the current system date and time. When it is set to 1990-00-00 00:00:00, it indicates immediate start of the 15-minute PM period monitoring. A reset of the period will terminate the ongoing monitoring and start a new monitoring. When the 15-minute PM period expires, the start date and time of the 15-minute PM period will be reset to zero." ::= { per15mMonitorTime 10 } -- 1.3.6.1.4.1.2011.2.25.3.40.20.10.10.20 per15mMonitorEndTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the end time and date of the 15-minute PM period. The end date and time of the 15-minute PM period must be set after the start date and time of the 15-minute PM period is set. And the end date and time of the 15-minute PM period must be later than the start date and time of the 15-minute PM period. When the end date and time of the 15-minute PM period is set to 1990-00-00 00:00:00, it indicates immediate end of the 15-minute PM period monitoring. When the 15-minute PM period expires, the end date and time of the 15-minute PM period will be reset to zero." ::= { per15mMonitorTime 20 } -- 1.3.6.1.4.1.2011.2.25.3.40.20.10.20 per24hMonitorTime OBJECT IDENTIFIER ::= { perMonitorTime 20 } -- 1.3.6.1.4.1.2011.2.25.3.40.20.10.20.10 per24hMonitorStartTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the start date and time of the 24-hour PM period. When the system is at this time, the 24-hour PM period monitoring starts. The start date and time of the 24-hour PM period cannot be set to be earlier than the current system date and time. When it is set to 1990-00-00 00:00:00, it indicates immediate start of the 24-hour PM period monitoring. A reset of the period will terminate the ongoing monitoring and start a new monitoring. When the 24-hour PM period expires, the start date and time of the 24-hour PM period will be reset to zero." ::= { per24hMonitorTime 10 } -- 1.3.6.1.4.1.2011.2.25.3.40.20.10.20.20 per24hMonitorEndTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the end date and time of the 24-hour PM period. The end date and time of the 24-hour PM period must be set after the start date and time of the 24-hour PM period is set. And the end date and time of the 24-hour PM period must be later than the start date and time of the 24-hour PM period. When the end date and time of the 24-hour PM period is set to 1990-00-00 00:00:00, it indicates immediate end of the 24-hour PM period monitoring. When the 24-hour PM period expires, the end date and time of the 24-hour PM period will be reset to zero." ::= { per24hMonitorTime 20 } END