-- OPTIX-PW-OAM-MIB -- MIB generated by ExcelToMIB tool 1.0 -- -- ================================================================= -- Copyright (C) 2012 by HUAWEI TECHNOLOGIES. All rights reserved -- Description: -- Reference: -- Version: V1.00 -- History: -- ,, -- ================================================================= -- OPTIX-PW-OAM-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-GROUP,MODULE-COMPLIANCE FROM SNMPv2-CONF MODULE-IDENTITY,OBJECT-TYPE,Unsigned32,Integer32,IpAddress FROM SNMPv2-SMI RowStatus FROM SNMPv2-TC optixProvisionPtn FROM OPTIX-OID-MIB ; optixPWOamMod MODULE-IDENTITY LAST-UPDATED "201204170000Z" ORGANIZATION "Huawei Technologies co.,Ltd." CONTACT-INFO "R&D Building Huawei Technologies Co., Ltd. Bantian, Longgang District Shenzhen, P. R. China http://www.huawei.com Zip:518129 E-mail:support@huawei.com" DESCRIPTION "This module is used to configure and manage the MPLS PW OAM. The PW OAM provides complete fault detection and identification mechanism and network performance monitoringat the PW layer. Based on the OAM check result, the equipment determines whether to trigger protection switching. The PW OAM enables quick faultdetection and identificationand service protection." REVISION "201204170000Z" DESCRIPTION "Initial version of this MIB module" ::={ optixProvisionPtn 7 } -- 1.3.6.1.4.1.2011.2.25.4.50.7.1 optixPWOamObject OBJECT IDENTIFIER ::= { optixPWOamMod 1 } -- 1.3.6.1.4.1.2011.2.25.4.50.7.1.1 optixPWOamTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixPWOamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Thistable is used to configure PW OAM attributes, including the PW OAM enable status, detection mode, CC detection mode, and SD/SF thresholds." ::= { optixPWOamObject 1 } -- 1.3.6.1.4.1.2011.2.25.4.50.7.1.1.1 optixPWOamEntry OBJECT-TYPE SYNTAX OptixPWOamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Thisentry is used to manage PW OAM attributes." INDEX{ optixPWOamIndex } ::= { optixPWOamTable 1 } OptixPWOamEntry ::= SEQUENCE { optixPWOamIndex Unsigned32, optixPWOamEnable INTEGER, optixPWOamCheckWay INTEGER, optixPWOamCcType INTEGER, optixPWOamCcTime Unsigned32, optixPWOamSf Unsigned32, optixPWOamSd Unsigned32, optixPWOamPeerLsrId IpAddress, optixPWOamPeerPwId Unsigned32, optixPWOamStandard INTEGER } -- 1.3.6.1.4.1.2011.2.25.4.50.7.1.1.1.1 optixPWOamIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the PW OAM index, ranging from 1 to 0x00ffffff." ::= { optixPWOamEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.50.7.1.1.1.2 optixPWOamEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether the OAM is enabled. 1: enable 0: disable" DEFVAL{ 0 } ::= { optixPWOamEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.50.7.1.1.1.3 optixPWOamCheckWay OBJECT-TYPE SYNTAX INTEGER { auto(1), manual(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the OAM detection mode. 1: auto 2: manual" DEFVAL{ 1 } ::= { optixPWOamEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.50.7.1.1.1.4 optixPWOamCcType OBJECT-TYPE SYNTAX INTEGER { cv(1), ffd(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the CC detection packet type. 1: cv (default value) 2: ffd" DEFVAL{ 1 } ::= { optixPWOamEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.50.7.1.1.1.5 optixPWOamCcTime OBJECT-TYPE SYNTAX Unsigned32(1..7|255) MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the CC detection packet frequency. When the packet type is cv, the frequency is an invalid value, 0xff. When the packet type is ffd, the valid value of the frequency is as follows: 1: 3.3 ms 2: 10 ms 3: 20 ms 4: 50 ms 5: 100 ms 6: 200 ms 7: 500 ms" DEFVAL{ 255 } ::= { optixPWOamEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.50.7.1.1.1.6 optixPWOamSf OBJECT-TYPE SYNTAX Unsigned32(0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the SF threshold (packet loss rate). Valid values range from 0 to 100." DEFVAL{ 0 } ::= { optixPWOamEntry 6 } -- 1.3.6.1.4.1.2011.2.25.4.50.7.1.1.1.7 optixPWOamSd OBJECT-TYPE SYNTAX Unsigned32(0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the SD threshold (packet loss rate). Valid values range from 0 to 100." DEFVAL{ 0 } ::= { optixPWOamEntry 7 } -- 1.3.6.1.4.1.2011.2.25.4.50.7.1.1.1.8 optixPWOamPeerLsrId OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the LSR ID to receive, which is the LSR ID of the valid MPLS device. 0.0.0.0: indicates that the peer IP address of the local PW is automatically obtained." DEFVAL{ 0 } ::= { optixPWOamEntry 8 } -- 1.3.6.1.4.1.2011.2.25.4.50.7.1.1.1.9 optixPWOamPeerPwId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the remote PW ID, which is a valid MPLS PW ID. 0: indicates that the ID of the local PW is automatically obtained." DEFVAL{ 0 } ::= { optixPWOamEntry 9 } -- 1.3.6.1.4.1.2011.2.25.4.50.7.1.1.1.10 optixPWOamStandard OBJECT-TYPE SYNTAX INTEGER { y1711(1), y1731(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the OAM protocol standard  1: 1711 2: 1731" DEFVAL{ 1 } ::= { optixPWOamEntry 10 } -- 1.3.6.1.4.1.2011.2.25.4.50.7.1.2 optixPWOamStateTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixPWOamStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Thistable is used to query the PW OAM status." ::= { optixPWOamObject 2 } -- 1.3.6.1.4.1.2011.2.25.4.50.7.1.2.1 optixPWOamStateEntry OBJECT-TYPE SYNTAX OptixPWOamStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Thisentry is used to manage the PW OAM status." INDEX{ optixPWOamIndex,optixPWOamDirection } ::= { optixPWOamStateTable 1 } OptixPWOamStateEntry ::= SEQUENCE { optixPWOamDirection INTEGER, optixPWOamState INTEGER, optixPWOamDefectType INTEGER, optixPWOamUnavailableTime Unsigned32, optixPWOamDefectPosition IpAddress } -- 1.3.6.1.4.1.2011.2.25.4.50.7.1.2.1.1 optixPWOamDirection OBJECT-TYPE SYNTAX INTEGER { farend(0), nearend(1) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "For bidirectional MPLS PWs, the status query is performed in two directions, local and remote ends. This object indicates the direction of the PW OAM. The status query is performed in single direction: local or remote end." ::= { optixPWOamStateEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.50.7.1.2.1.2 optixPWOamState OBJECT-TYPE SYNTAX INTEGER { initialstate(0), nearendavailable(1), nearenddefectavailable(2), nearenddefectunavailable(3), nearendunavailable(4), farendavailable(5), farenddefectavailable(6), farenddefectunavailable(7), farendunavailable(8) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the PW OAM status. 0: initialstate, 1: nearendavailable, 2: nearenddefectavailable, 3: nearenddefectunavailable, 4: nearendunavailable, 5: farendavailable, 6: farenddefectavailable, 7: farenddefectunavailable, 8: farendunavailable" ::= { optixPWOamStateEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.50.7.1.2.1.3 optixPWOamDefectType OBJECT-TYPE SYNTAX INTEGER { dserver(1), dpeerme(2), dlocv(3), dttsimismatch(4), dttsimismerge(5), dexcess(6), dunknown(7), invalid(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the defect type of the PW OAM. 1: dserver, 2: dpeerme, 3: dlocv, 4: dttsimismatch, 5: dttsimismerge, 6: dexcess, 7: dunknown, 255: invalid" ::= { optixPWOamStateEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.50.7.1.2.1.4 optixPWOamUnavailableTime OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the unavailable time of the PW OAM. The time ranges from 0 to 300,000 ms. 4294967295: invalid" ::= { optixPWOamStateEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.50.7.1.2.1.5 optixPWOamDefectPosition OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the position of the PW OAM defect: a node identified by IP address." ::= { optixPWOamStateEntry 5 } END