LANCOM-ES-2126P-MIB DEFINITIONS ::= BEGIN IMPORTS DisplayString FROM SNMPv2-TC MODULE-COMPLIANCE,OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF enterprises,MODULE-IDENTITY,OBJECT-TYPE,NOTIFICATION-TYPE,Counter32,IpAddress FROM SNMPv2-SMI ifIndex FROM RFC1213-MIB; -- @ENTERPRISE-SECTION-START lancomSystems MODULE-IDENTITY LAST-UPDATED "200806030000Z" ORGANIZATION "LANCOM Systems GmbH" CONTACT-INFO "Adenauerstrasse 20 / B2, 52146 Wuerselen, Germany Email: info@lancom.de TEL: +49 (0)2405 49936 0 FAX: +49 (0)2405 49936 99" DESCRIPTION "The MIB module is for LANCOM Systems" ::= { enterprises 2356 } switchingSystems OBJECT IDENTIFIER ::= { lancomSystems 800 } fastEthernetSwitches OBJECT IDENTIFIER ::= { switchingSystems 2 } lancomES2126P OBJECT IDENTIFIER ::= { fastEthernetSwitches 2127 } -- @ENTERPRISE-SECTION-END es2126pProduces OBJECT IDENTIFIER ::= { lancomES2126P 1 } es2126pSystem OBJECT IDENTIFIER ::= { es2126pProduces 1 } es2126pCommonSys OBJECT IDENTIFIER ::= { es2126pSystem 1 } es2126pReboot OBJECT-TYPE SYNTAX INTEGER(0|1|2) MAX-ACCESS read-write STATUS current DESCRIPTION "Reboot the system. Get this OID always return zero. 0 - do nothing 1 - Reboot without saving start 2 - Reboot with saving start" ::= { es2126pCommonSys 1 } es2126pBiosVsersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Get the BIOS version of the system." ::= { es2126pCommonSys 2 } es2126pFirmwareVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Get the firmware version of the system." ::= { es2126pCommonSys 3 } es2126pHardwareVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Get the hardware version of the system." ::= { es2126pCommonSys 4 } es2126pMechanicalVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Get the mechanical version of the system." ::= { es2126pCommonSys 5 } es2126pSerialNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Get the Serial number of the system." ::= { es2126pCommonSys 6 } es2126pHostMacAddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Get the MAC address of the system." ::= { es2126pCommonSys 7 } es2126pDevicePort OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Get the quantity of ports that this system owns now." ::= { es2126pCommonSys 8 } es2126pRamSize OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Get the RAM size of the system." ::= { es2126pCommonSys 9 } es2126pFlashSize OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Get the flash size of the system." ::= { es2126pCommonSys 10 } es2126pIP OBJECT IDENTIFIER ::= { es2126pSystem 2 } es2126pDhcpSetting OBJECT-TYPE SYNTAX INTEGER(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Get/Set DHCP status of the system. 0 - DHCP disable 1 - DHCP enable" ::= { es2126pIP 1 } es2126pIPAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Get/Set the IP address of the system. You can't set this OID if DHCP status is enabled." ::= { es2126pIP 2 } es2126pNetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Get/Set the subnet mask of the system. You can't set this OID if DHCP status is enabled." ::= { es2126pIP 3 } es2126pDefaultGateway OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Get/Set the default gateway of the system. You can't set this OID if DHCP status is enabled." ::= { es2126pIP 4 } es2126pDnsSetting OBJECT-TYPE SYNTAX INTEGER(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Get/Set the source of DNS server. You can't set this OID if DHCP status is disabled. 0 - manual, the DNS server is from manual setting 1 - Auto, the DNS server is assigned by DHCP server." ::= { es2126pIP 5 } es2126pDnsServer OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Get/Set the DNS server of the system." ::= { es2126pIP 6 } es2126pTime OBJECT IDENTIFIER ::= { es2126pSystem 3 } es2126pSystemCurrentTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Get the current time of the system." ::= { es2126pTime 1 } es2126pManualTimeSetting OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Get/Set the system time of the device. The input format is 'Year/Month/Day/Hour/Minute/Second'. Ex: 2004/1/1/12/34/25 means 2004/1/1 - 12:24:25. Value range: Year : 2000 - 2036, Mouth : 1 - 12, Day : 1 - 31, Hour : 0 - 23, Minute : 0 - 59, Sec : 0 - 59." ::= { es2126pTime 2 } es2126pNTPServer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Get/Set the NTP Time Server. You can use the IP address or domain name." ::= { es2126pTime 3 } es2126pNTPTimeZone OBJECT-TYPE SYNTAX INTEGER(-12..13) MAX-ACCESS read-write STATUS current DESCRIPTION "Get/Set the NTP Time Zone. Value range is between -12 and 13 -12 - GMT -12:00, -11 - GMT -11:00, -10 - GMT -10:00, -9 - GMT -09:00, -8 - GMT -08:00, -7 - GMT -07:00, -6 - GMT -06:00, -5 - GMT -05:00, -4 - GMT -04:00, -3 - GMT -03:00, -2 - GMT -02:00, -1 - GMT -01:00, 0 - GMT +00:00, 1 - GMT +01:00, 2 - GMT +02:00, 3 - GMT +03:00, 4 - GMT +04:00, 5 - GMT +05:00, 6 - GMT +06:00, 7 - GMT +07:00, 8 - GMT +08:00, 9 - GMT +09:00, 10 - GMT +10:00, 11 - GMT +11:00, 12 - GMT +12:00, 13 - GMT +13:00. " ::= { es2126pTime 4 } es2126pNTPTimeSync OBJECT-TYPE SYNTAX INTEGER(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Sync time from NTP Server. Get this OID always return zero. Set the Time Server and Time Zone before doing time sync. Notice that time server must be correct! Value range (1|0): 1 - Sync. 0 - do nothing." ::= { es2126pTime 5 } es2126pDaylightSavingTime OBJECT-TYPE SYNTAX INTEGER(-5..5) MAX-ACCESS read-write STATUS current DESCRIPTION "Get/Set the daylight saving time. Value range is between -5 and 5. Unit: hour. " ::= { es2126pTime 6 } es2126pDaylightStartTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Get/Set the Start time of Daylight Saving. The input format is 'MM/DD/HH', and daylight saving start month can't equal end month. Example: month/day/hour 10/01/00 Month: 01~12, day: 01~31, hour: 00~23." ::= { es2126pTime 7 } es2126pDaylightEndTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Get/Set the End time of Daylight Saving. The input format is 'MM/DD/HH', and daylight saving start month can't equal end month. Example: month/day/hour 04/01/00 Month: 01~12, day: 01~31, hour: 00~23." ::= { es2126pTime 8 } es2126pAccount OBJECT IDENTIFIER ::= { es2126pSystem 4 } es2126pAccountNumber OBJECT-TYPE SYNTAX INTEGER(1..5) MAX-ACCESS read-only STATUS current DESCRIPTION "Get the current account number(s) of the system." ::= { es2126pAccount 1 } es2126pAccountTable OBJECT-TYPE SYNTAX SEQUENCE OF ES2126PAccountEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a list of es2126pAccountEntry. The numbers of entries are given by the value of es2126pAccountNumber." ::= { es2126pAccount 2 } ES2126PAccountEntry ::= SEQUENCE { es2126pAccountIndex INTEGER, es2126pAccountAuthorization DisplayString, es2126pAccountName DisplayString, es2126pAccountPassword DisplayString } es2126pAccountEntry OBJECT-TYPE SYNTAX ES2126PAccountEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is the Entry(s) for account information." INDEX {es2126pAccountIndex} ::= { es2126pAccountTable 1 } es2126pAccountIndex OBJECT-TYPE SYNTAX INTEGER(1..5) MAX-ACCESS read-only STATUS current DESCRIPTION "This is the index of the account entry." ::= { es2126pAccountEntry 1 } es2126pAccountAuthorization OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This is the authorization of the account entry." ::= { es2126pAccountEntry 2 } es2126pAccountName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This is the username of the account entry." ::= { es2126pAccountEntry 3 } es2126pAccountPassword OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This is the password of the account entry. The return value is always '********'." ::= { es2126pAccountEntry 4 } es2126pAccountAddName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This is the account name for adding operation." ::= { es2126pAccount 3 } es2126pAccountAddPassword OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This is the account password for adding operation. The return value is always '********'." ::= { es2126pAccount 4 } es2126pDoAccountAdd OBJECT-TYPE SYNTAX INTEGER(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Add account name. OID es2126pAccountAddName and es2126pAccountAddPassword must be filled first. Get this OID always return zero. 1 - Add account. 0 - do nothing." ::= { es2126pAccount 5 } es2126pAccountDel OBJECT-TYPE SYNTAX INTEGER(2..5) MAX-ACCESS read-write STATUS current DESCRIPTION "Delete account. The value is valid es2126pAccountIndex(Can't delete administrator)." ::= { es2126pAccount 6 } es2126pSnmp OBJECT IDENTIFIER ::= { es2126pProduces 2 } es2126pGetCommunity OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Get/Set the get-community of the SNMP." ::= { es2126pSnmp 1 } es2126pSetCommunity OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Get/Set the set-community of the SNMP." ::= { es2126pSnmp 2 } es2126pTrapHostNumber OBJECT-TYPE SYNTAX INTEGER(1..6) MAX-ACCESS read-only STATUS current DESCRIPTION "Get the number of trap hosts." ::= { es2126pSnmp 3 } es2126pTrapHostTable OBJECT-TYPE SYNTAX SEQUENCE OF ES2126PTrapHostEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a list of trap host entry. The numbers of entries are given by the value of es2126pTrapHostNumber." ::= { es2126pSnmp 4 } ES2126PTrapHostEntry ::= SEQUENCE { es2126pTrapHostIndex INTEGER, es2126pTrapHostIP IpAddress, es2126pTrapHostPort INTEGER, es2126pTrapHostCommunity DisplayString } es2126pTrapHostEntry OBJECT-TYPE SYNTAX ES2126PTrapHostEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is the Entry Information for trap host." INDEX {es2126pTrapHostIndex} ::= { es2126pTrapHostTable 1 } es2126pTrapHostIndex OBJECT-TYPE SYNTAX INTEGER(1..6) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the trap host entry." ::= { es2126pTrapHostEntry 1 } es2126pTrapHostIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "This is the IP of the trap host." ::= { es2126pTrapHostEntry 2 } es2126pTrapHostPort OBJECT-TYPE SYNTAX INTEGER(1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "This is the receiving-port number of the trap host." ::= { es2126pTrapHostEntry 3 } es2126pTrapHostCommunity OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The community name for the trap PDU." ::= { es2126pTrapHostEntry 4 } es2126pRegisterMonitor OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Register-Monitor" ::= { es2126pSnmp 5 } es2126pDeleteMonitor OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Delete-Monitor" ::= { es2126pSnmp 6 } es2126pMonitorTable OBJECT-TYPE SYNTAX SEQUENCE OF ES2126PMonitorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Monitor-Table" ::= { es2126pSnmp 7 } ES2126PMonitorEntry ::= SEQUENCE { es2126pMonitorTableIp IpAddress, es2126pMonitorTableMac DisplayString } es2126pMonitorEntry OBJECT-TYPE SYNTAX ES2126PMonitorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "entry in table" INDEX { es2126pMonitorTableIp } ::= { es2126pMonitorTable 1 } es2126pMonitorTableIp OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "IP-Address" ::= { es2126pMonitorEntry 1 } es2126pMonitorTableMac OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "MAC-Address" ::= { es2126pMonitorEntry 2 } es2126pAlarm OBJECT IDENTIFIER ::= { es2126pProduces 3 } es2126pEvent OBJECT IDENTIFIER ::= { es2126pAlarm 1 } es2126pEventNumber OBJECT-TYPE SYNTAX INTEGER(1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Get the total number of alarm events." ::= { es2126pEvent 1 } es2126pEventTable OBJECT-TYPE SYNTAX SEQUENCE OF ES2126PEventEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a list of alarm event entry. The numbers of entries are given by the value of es2126pEventNumber." ::= { es2126pEvent 2 } ES2126PEventEntry ::= SEQUENCE { es2126pEventIndex INTEGER, es2126pEventName DisplayString, es2126pEventSendEmail INTEGER, es2126pEventSendSMS INTEGER, es2126pEventSendTrap INTEGER } es2126pEventEntry OBJECT-TYPE SYNTAX ES2126PEventEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is the entry information for alarm event." INDEX {es2126pEventIndex} ::= { es2126pEventTable 1 } es2126pEventIndex OBJECT-TYPE SYNTAX INTEGER(1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "This is the index of the alarm event entry." ::= { es2126pEventEntry 1 } es2126pEventName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This is the alarm event name." ::= { es2126pEventEntry 2 } es2126pEventSendEmail OBJECT-TYPE SYNTAX INTEGER(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Send email when alarm event is triggered." ::= { es2126pEventEntry 3 } es2126pEventSendSMS OBJECT-TYPE SYNTAX INTEGER(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Send SMS when alarm event is triggered." ::= { es2126pEventEntry 4 } es2126pEventSendTrap OBJECT-TYPE SYNTAX INTEGER(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Send trap when alarm event is triggered." ::= { es2126pEventEntry 5 } es2126pEmail OBJECT IDENTIFIER ::= { es2126pAlarm 2 } es2126pEmailServer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This is the SMTP server for alarm event." ::= { es2126pEmail 1 } es2126pEmailUsername OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This is the Username of SMTP server." ::= { es2126pEmail 2 } es2126pEmailPassword OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This is the User Password of SMTP server." ::= { es2126pEmail 3 } es2126pEmailUserNumber OBJECT-TYPE SYNTAX INTEGER(1..6) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of the email users that you want to send the alarm notification." ::= { es2126pEmail 4 } es2126pEmailUserTable OBJECT-TYPE SYNTAX SEQUENCE OF ES2126PEmailUserEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a list of email user entry. The numbers of entries are given by the value of es2126pEmailUserNumber." ::= { es2126pEmail 5 } ES2126PEmailUserEntry ::= SEQUENCE { es2126pEmailUserIndex INTEGER, es2126pEmailUserAddress DisplayString } es2126pEmailUserEntry OBJECT-TYPE SYNTAX ES2126PEmailUserEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is the Entry information for email user entry." INDEX {es2126pEmailUserIndex} ::= { es2126pEmailUserTable 1 } es2126pEmailUserIndex OBJECT-TYPE SYNTAX INTEGER(1..6) MAX-ACCESS read-only STATUS current DESCRIPTION "This is the index of the email user entry." ::= { es2126pEmailUserEntry 1 } es2126pEmailUserAddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This is the email address of the email user entry." ::= { es2126pEmailUserEntry 2 } es2126pSMS OBJECT IDENTIFIER ::= { es2126pAlarm 3 } es2126pSMSServer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This is the SMS server for alarm event." ::= { es2126pSMS 1 } es2126pSMSUsername OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This is the Username of SMS server." ::= { es2126pSMS 2 } es2126pSMSPassword OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This is the Password of SMS server." ::= { es2126pSMS 3 } es2126pSMSUserNumber OBJECT-TYPE SYNTAX INTEGER(1..6) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of the SMS users that you want to send the alarm notification." ::= { es2126pSMS 4 } es2126pSMSUserTable OBJECT-TYPE SYNTAX SEQUENCE OF ES2126PSMSUserEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a list of SMS user entry. The numbers of entries are given by the value of es2126pSMSUserNumber." ::= { es2126pSMS 5 } ES2126PSMSUserEntry ::= SEQUENCE { es2126pSMSUserIndex INTEGER, es2126pSMSUserMobilePhone DisplayString } es2126pSMSUserEntry OBJECT-TYPE SYNTAX ES2126PSMSUserEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is the Entry information for SMS user entry." INDEX {es2126pSMSUserIndex} ::= { es2126pSMSUserTable 1 } es2126pSMSUserIndex OBJECT-TYPE SYNTAX INTEGER(1..6) MAX-ACCESS read-only STATUS current DESCRIPTION "This is the index of the SMS user entry." ::= { es2126pSMSUserEntry 1 } es2126pSMSUserMobilePhone OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The SMS phone number of the SMS user entry." ::= { es2126pSMSUserEntry 2 } es2126pTftp OBJECT IDENTIFIER ::= { es2126pProduces 4 } es2126pTftpServer OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Get/Set the tftp server." ::= { es2126pTftp 1 } es2126pConfiguration OBJECT IDENTIFIER ::= { es2126pProduces 5 } es2126pSaveRestore OBJECT IDENTIFIER ::= { es2126pConfiguration 1 } es2126pSaveStart OBJECT-TYPE SYNTAX INTEGER(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Save current configuration into flash memory (Save as Start Configuration). Get this OID always return zero. 1 - Save. 0 - do nothing. " ::= { es2126pSaveRestore 1 } es2126pSaveUser OBJECT-TYPE SYNTAX INTEGER(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Save current configuration into flash memory (Save as User Configuration). Get this OID always return zero. 1 - Save. 0 - do nothing. " ::= { es2126pSaveRestore 2 } es2126pRestoreDefault OBJECT-TYPE SYNTAX INTEGER(0|1|2) MAX-ACCESS read-write STATUS current DESCRIPTION "Restore factory default configuration. Get this OID always return zero. 2 - Restore default included default ip address. 1 - Restore default without changing current ip address. 0 - do nothing. " ::= { es2126pSaveRestore 3 } es2126pRestoreUser OBJECT-TYPE SYNTAX INTEGER(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Restore user configuration. Get this OID always return zero. 1 - Restore. 0 - do nothing. " ::= { es2126pSaveRestore 4 } es2126pConfigFile OBJECT IDENTIFIER ::= { es2126pConfiguration 2 } es2126pExportConfigName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Get/Set the export file path and name." ::= { es2126pConfigFile 1 } es2126pDoExportConfig OBJECT-TYPE SYNTAX INTEGER(1|2) MAX-ACCESS read-write STATUS current DESCRIPTION "Do export-config. Get this OID always return zero. 1 - Export start section. 2 - Export user-conf section." ::= { es2126pConfigFile 2 } es2126pImportConfigName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Get/Set the import file path and name." ::= { es2126pConfigFile 3 } es2126pDoImportConfig OBJECT-TYPE SYNTAX INTEGER(1|2) MAX-ACCESS read-write STATUS current DESCRIPTION "Do import-config. Get this OID always return zero. 1 - Import start section. 2 - Import user-conf section." ::= { es2126pConfigFile 4 } es2126pDiagnostic OBJECT IDENTIFIER ::= { es2126pProduces 6 } es2126pEEPROMTest OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "EEPROM access test." ::= { es2126pDiagnostic 1 } es2126pUartTest OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "UART access test." ::= { es2126pDiagnostic 2 } es2126pDramTest OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "DRAM access test." ::= { es2126pDiagnostic 3 } es2126pFlashTest OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Flash memory access test." ::= { es2126pDiagnostic 4 } es2126pInternalLoopbackTest OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Internal loop back test." ::= { es2126pDiagnostic 5 } es2126pExternalLoopbackTest OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "External loop back test." ::= { es2126pDiagnostic 6 } es2126pPingTest OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Set the host address that you want to ping and the system will return the test result." ::= { es2126pDiagnostic 7 } es2126pLog OBJECT IDENTIFIER ::= { es2126pProduces 7 } es2126pClearLog OBJECT-TYPE SYNTAX INTEGER(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Clear system log. Get this OID always return zero. 1 - Clear log. 0 - do nothing. " ::= { es2126pLog 1 } es2126pUploadLog OBJECT-TYPE SYNTAX INTEGER(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Upload current system log. Set the correct tftp server first. The format of log file is 'ModelName_SerialNumbuer_YYMMDD_HHMM'. Get this OID always return zero. 1 - Upload log 0 - do nothing. " ::= { es2126pLog 2 } es2126pAutoUploadLogState OBJECT-TYPE SYNTAX INTEGER(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Enable auto-upload log function. Set the correct tftp server first. The format of log file is 'ModelName_SerialNumbuer_YYMMDD_HHMM'. Get this OID always return zero. 1 - Enable auto-upload 0 - do nothing. " ::= { es2126pLog 3 } es2126pLogNumber OBJECT-TYPE SYNTAX INTEGER(0..120) MAX-ACCESS read-only STATUS current DESCRIPTION "Get the number of current system log. " ::= { es2126pLog 4 } es2126pLogTable OBJECT-TYPE SYNTAX SEQUENCE OF ES2126PLogEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a list of log entry. The numbers of entries are given by the value of es2126pLogNumber." ::= { es2126pLog 5 } ES2126PLogEntry ::= SEQUENCE { es2126pLogIndex INTEGER, es2126pLogEvent DisplayString } es2126pLogEntry OBJECT-TYPE SYNTAX ES2126PLogEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is the Entry information for system log." INDEX {es2126pLogIndex} ::= { es2126pLogTable 1 } es2126pLogIndex OBJECT-TYPE SYNTAX INTEGER(1..120) MAX-ACCESS read-only STATUS current DESCRIPTION "This is the index of the log entry." ::= { es2126pLogEntry 1 } es2126pLogEvent OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This is the detail information of the log entry." ::= { es2126pLogEntry 2 } es2126pFirmware OBJECT IDENTIFIER ::= { es2126pProduces 8 } es2126pFirmwareFileName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Get/Set the path and filename for firmware upgrading." ::= { es2126pFirmware 1 } es2126pDoFirmwareUpgrade OBJECT-TYPE SYNTAX INTEGER(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Do firmware upgrade. Get this OID always return zero. 1 - Do firmware upgrade. 0 - do nothing." ::= { es2126pFirmware 2 } es2126pPort OBJECT IDENTIFIER ::= { es2126pProduces 9 } es2126pPortStatus OBJECT IDENTIFIER ::= { es2126pPort 1 } es2126pPortStatusNumber OBJECT-TYPE SYNTAX INTEGER(1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Get the number of port." ::= { es2126pPortStatus 1 } es2126pPortStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF ES2126PPortStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a list of port status entry. The numbers of entries are given by the value of es2126pPortStatusNumber." ::= { es2126pPortStatus 2 } ES2126PPortStatusEntry ::= SEQUENCE { es2126pPortStatusIndex INTEGER, es2126pPortStatusMedia DisplayString, es2126pPortStatusLink DisplayString, es2126pPortStatusPortState DisplayString, es2126pPortStatusAutoNego DisplayString, es2126pPortStatusSpdDpx DisplayString, es2126pPortStatusRxPause DisplayString, es2126pPortStatusTxPause DisplayString, es2126pPortStatusDescription DisplayString } es2126pPortStatusEntry OBJECT-TYPE SYNTAX ES2126PPortStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is the entry(s) for port status information." INDEX {es2126pPortStatusIndex} ::= { es2126pPortStatusTable 1 } es2126pPortStatusIndex OBJECT-TYPE SYNTAX INTEGER(1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "This is the index of the port status entry." ::= { es2126pPortStatusEntry 1 } es2126pPortStatusMedia OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The port media type of the port status entry." ::= { es2126pPortStatusEntry 2 } es2126pPortStatusLink OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This is the port link of the port status entry." ::= { es2126pPortStatusEntry 3 } es2126pPortStatusPortState OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This is the port state of the port status entry." ::= { es2126pPortStatusEntry 4 } es2126pPortStatusAutoNego OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This is the auto negotiation of the port status entry." ::= { es2126pPortStatusEntry 5 } es2126pPortStatusSpdDpx OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This is the speed/duplex of the port status entry." ::= { es2126pPortStatusEntry 6 } es2126pPortStatusRxPause OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The Rx Pause of the port status entry." ::= { es2126pPortStatusEntry 7 } es2126pPortStatusTxPause OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The Tx Pause of the port status entry." ::= { es2126pPortStatusEntry 8 } es2126pPortStatusDescription OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This is the description of port." ::= { es2126pPortStatusEntry 9 } es2126pPortConf OBJECT IDENTIFIER ::= { es2126pPort 2 } es2126pPortConfNumber OBJECT-TYPE SYNTAX INTEGER(1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Get the number of port configuration." ::= { es2126pPortConf 1 } es2126pPortConfTable OBJECT-TYPE SYNTAX SEQUENCE OF ES2126PPortConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a list of port configuration entry. The numbers of entries are given by the value of es2126pPortConfNumber." ::= { es2126pPortConf 2 } ES2126PPortConfEntry ::= SEQUENCE { es2126pPortConfIndex INTEGER, es2126pPortConfPortState INTEGER, es2126pPortConfSpdDpx INTEGER, es2126pPortConfFlwCtrl INTEGER, es2126pPortConfDescription DisplayString } es2126pPortConfEntry OBJECT-TYPE SYNTAX ES2126PPortConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is the Entry(s) for port configuration information." INDEX {es2126pPortConfIndex} ::= { es2126pPortConfTable 1 } es2126pPortConfIndex OBJECT-TYPE SYNTAX INTEGER(1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "This is the index of the port configuration entry." ::= { es2126pPortConfEntry 1 } es2126pPortConfPortState OBJECT-TYPE SYNTAX INTEGER(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "This is the port state of the port configuration entry. 0 - disabled. 1 - enabled. " ::= { es2126pPortConfEntry 2 } es2126pPortConfSpdDpx OBJECT-TYPE SYNTAX INTEGER(0..5) MAX-ACCESS read-write STATUS current DESCRIPTION "This is the speed/duplex of the port configuration entry. 0 - auto. 1 - 10M/Half. 2 - 10M/Full. 3 - 100M/Half. 4 - 100M/Full. 5 - 1G/Full. " ::= { es2126pPortConfEntry 3 } es2126pPortConfFlwCtrl OBJECT-TYPE SYNTAX INTEGER(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "This is the flow control of the port configuration entry. 0 - asymmetric. 1 - symmetric. " ::= { es2126pPortConfEntry 4 } es2126pPortConfDescription OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This is the description of port." ::= { es2126pPortConfEntry 5 } es2126pLoopDetectedConf OBJECT IDENTIFIER ::= { es2126pProduces 10 } es2126pLoopDetectedNumber OBJECT-TYPE SYNTAX INTEGER(1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Get the number of loop detected entry." ::= { es2126pLoopDetectedConf 1 } es2126pLoopDetectedTable OBJECT-TYPE SYNTAX SEQUENCE OF ES2126PLoopDetectedEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a list of loop detected entry. The number of entries are given by the value of es2126pLoopDetectedNumber." ::= { es2126pLoopDetectedConf 2 } ES2126PLoopDetectedEntry ::= SEQUENCE { es2126pLoopDetectedfIndex INTEGER, es2126pLoopDetectedStateEbl INTEGER, es2126pLoopDetectedCurrentStatus INTEGER, es2126pLoopDetectedRemoved INTEGER } es2126pLoopDetectedEntry OBJECT-TYPE SYNTAX ES2126PLoopDetectedEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry(s) for loop detected information." INDEX {es2126pLoopDetectedfIndex} ::= { es2126pLoopDetectedTable 1 } es2126pLoopDetectedfIndex OBJECT-TYPE SYNTAX INTEGER(1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "This is the index of the loop detected entry." ::= { es2126pLoopDetectedEntry 1 } es2126pLoopDetectedStateEbl OBJECT-TYPE SYNTAX INTEGER(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "The state of the loop detected entry. 0 - disabled. 1 - enabled. " ::= { es2126pLoopDetectedEntry 2 } es2126pLoopDetectedCurrentStatus OBJECT-TYPE SYNTAX INTEGER(0|1) MAX-ACCESS read-only STATUS current DESCRIPTION "The current status of the loop detected port. 0 - Unlocked 1 - Locked due to the loop condition " ::= { es2126pLoopDetectedEntry 3 } es2126pLoopDetectedRemoved OBJECT-TYPE SYNTAX INTEGER(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Unlock the port which is locked due to loop condition. Get this OID always return zero. 1 - Unlock the port, 0 - do nothing." ::= { es2126pLoopDetectedEntry 4 } es2126pLoopDetectedAction OBJECT-TYPE SYNTAX INTEGER(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Set the corresponding action while loop is detected. 1 - Lock the loop port, 0 - do nothing." ::= { es2126pLoopDetectedConf 3 } es2126pTrapEntry OBJECT IDENTIFIER ::= { es2126pProduces 20 } es2126pModuleInserted NOTIFICATION-TYPE OBJECTS { ifIndex } STATUS current DESCRIPTION "Send the trap when a module is inserted to the system. The OID value means the port number." ::= { es2126pTrapEntry 1 } es2126pModuleRemoved NOTIFICATION-TYPE OBJECTS { ifIndex } STATUS current DESCRIPTION "Send the trap when a module is removed from the system. The OID value means the port number." ::= { es2126pTrapEntry 2 } es2126pDualMediaSwapped NOTIFICATION-TYPE OBJECTS { ifIndex } STATUS current DESCRIPTION "Send the trap when the dual media port changed. The OID value means the port number." ::= { es2126pTrapEntry 3 } es2126pPoEFailure NOTIFICATION-TYPE STATUS current DESCRIPTION "Send the trap while detecting the malfunction of PoE chips." ::= { es2126pTrapEntry 4 } es2126pLoopDetected NOTIFICATION-TYPE OBJECTS { ifIndex } STATUS current DESCRIPTION "Send the trap when loop condition has been detected. The OID value means the port number." ::= { es2126pTrapEntry 5 } es2126pStpStateDisabled NOTIFICATION-TYPE STATUS current DESCRIPTION "Send the trap when the operational state of STP is from enabled to disabled. " ::= { es2126pTrapEntry 100 } es2126pStpStateEnabled NOTIFICATION-TYPE STATUS current DESCRIPTION "Send the trap when the operational state of STP is from disabled to enabled. " ::= { es2126pTrapEntry 101 } es2126pStpTopologyChanged NOTIFICATION-TYPE OBJECTS { ifIndex } STATUS current DESCRIPTION "Send the trap when RSTP determines a port should enter the FORWARDING state (a topology change occurs). The OID value is the ifIndex of the port that produces the topology change." ::= { es2126pTrapEntry 102 } es2126pRmonRisingAlarm NOTIFICATION-TYPE STATUS current DESCRIPTION "Send the trap when an RMON rising alarm happened. The OID value is the value of another OID variable sampled by the RMON Alarm Group that exceeds its own RisingThreshold " ::= { es2126pTrapEntry 110 } es2126pRmonFallingAlarm NOTIFICATION-TYPE STATUS current DESCRIPTION "Send the trap when an RMON falling alarm happened. The OID value is the value of another OID variable sampled by the RMON Alarm Group that is smaller than its own FallingThreshold " ::= { es2126pTrapEntry 111 } es2126pLacpStateDisabled NOTIFICATION-TYPE OBJECTS {ifIndex, groupId} STATUS current DESCRIPTION "Send the trap when the operational state of LACP is from enabled to disabled. The OID value means the disabled Group ID." ::= { es2126pTrapEntry 120 } es2126pLacpStateEnabled NOTIFICATION-TYPE OBJECTS {ifIndex, groupId} STATUS current DESCRIPTION "Send the trap when the operational state of LACP is from disabled to enabled. The OID value means the disabled Group ID." ::= { es2126pTrapEntry 121 } es2126pLacpPortAdded NOTIFICATION-TYPE OBJECTS { ifIndex, actorkey, partnerkey } STATUS current DESCRIPTION "Send the trap when the state of port is in 'trunk ready'." ::= { es2126pTrapEntry 123 } es2126pLacpPortTrunkFailure NOTIFICATION-TYPE OBJECTS { ifIndex, actorkey, partnerkey} STATUS current DESCRIPTION "Send the trap when one port is not able to be aggregated due to duplex-mode of the port. " ::= { es2126pTrapEntry 124 } es2126pGvrpStateDisabled NOTIFICATION-TYPE STATUS current DESCRIPTION "Send the trap when the operational state of GVRP is from enabled to disabled. " ::= { es2126pTrapEntry 140 } es2126pGvrpStateEnabled NOTIFICATION-TYPE STATUS current DESCRIPTION "Send the trap when the operational state of LACP is from disabled to enabled. " ::= { es2126pTrapEntry 141 } es2126pVlanPortBaseEnabled NOTIFICATION-TYPE STATUS current DESCRIPTION "Send the trap when the operational state of vlan is changed to port-based vlan." ::= { es2126pTrapEntry 151 } es2126pVlanTagBaseEnabled NOTIFICATION-TYPE STATUS current DESCRIPTION "Send the trap when the operational state of vlan is changed to tag-based vlan." ::= { es2126pTrapEntry 152 } es2126pVlanMetroBaseEnabled NOTIFICATION-TYPE STATUS current DESCRIPTION "Send the trap when the operational state of vlan is changed to metro-based vlan." ::= { es2126pTrapEntry 153 } es2126pUserLogin NOTIFICATION-TYPE OBJECTS {username} STATUS current DESCRIPTION "Send the trap when one user logins the system." ::= { es2126pTrapEntry 200 } es2126pUserLogout NOTIFICATION-TYPE OBJECTS {username} STATUS current DESCRIPTION "Send the trap when one user logouts the system." ::= { es2126pTrapEntry 201 } es2126pTrapVariable OBJECT IDENTIFIER ::= { es2126pProduces 21 } username OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "System account name." ::= { es2126pTrapVariable 1 } groupId OBJECT-TYPE SYNTAX INTEGER(1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "The Trunk group ID of LACP." ::= { es2126pTrapVariable 2 } actorkey OBJECT-TYPE SYNTAX INTEGER(1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The actor key information for LACP." ::= { es2126pTrapVariable 3 } partnerkey OBJECT-TYPE SYNTAX INTEGER(1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The partner key information for LACP." ::= { es2126pTrapVariable 4 } uplink OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Uplink port(s) in the metro-mode vlan." ::= { es2126pTrapVariable 5 } END