-- -- file :rad0485.pkb -- RAD-MIB DEFINITIONS ::= BEGIN --RAD0485-MIB --Last revision: 01/10/02 SMI-v2 -- -- --Title: rad0400 MIB -- *** This file is for the modified newmasking MIB. *** -- Copyright 2000 RAD Data Communications, Ltd. -- All Rights Reserved. -- It is RAD's intent to encourage the widespread use of -- this Specification in connection with the management of -- RAD products. RAD grants vendors, end-users, -- and other interested parties a non-exclusive license to -- use this Specification in connection with the management -- of RAD products. -- This Specification is supplied "as is," and RAD makes -- no warranty, either express or implied, as to the use, -- operation, condition, or performance of the Specification. IMPORTS fddimibPORTPCMState FROM FDDI-SMT73-MIB rptrGroupOperStatus, rptrPortOperStatus FROM SNMP-REPEATER-MIB rpMauMediaAvailable FROM MAU-MIB -- OBJECT-TYPE , Integer32 , Counter32, TimeTicks,enterprises, IpAddress, Gauge32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY FROM SNMPv2-SMI TimeStamp, TAddress, -- TEXTUAL-CONVENTION, DisplayString, RowStatus, DateAndTime, TruthValue FROM SNMPv2-TC -- MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF AtmTrafficDescrParamIndex FROM ATM-TC-MIB -- AtmTrafficDescrParamIndex, atmVplVpi, atmVclVpi, atmVclVci, aal5VccVpi, aal5VccVci, atmVclEntry, aal5VccEntry FROM ATM-MIB frPVCEndptDLCIIndex FROM FRNETSERV-MIB VlanIndex FROM Q-BRIDGE-MIB atmfCESCbrIndex, atmfCESConfEntry FROM ATMF-CES InterfaceIndex, ifAlias, ifIndex FROM IF-MIB imaGroupIndex, imaLinkIfIndex, imaGroupFailureStatus FROM IMA-MIB dsx1LineStatus, dsx1LineStatusLastChange, dsx1CurrentIndex, dsx1LineIndex, dsx1IntervalIndex, dsx1IntervalNumber, dsx1LoopbackStatus, dsx1TotalIndex FROM DS1-MIB dsx3LineStatus, dsx3LoopbackStatus FROM DS3-MIB PerfCurrentCount, PerfIntervalCount, PerfTotalCount FROM PerfHist-TC-MIB MmTAddressTag,MmEndpointID, MmAliasAddress,MmH323EndpointType, MmGatekeeperID,MmAliasTag FROM MULTI-MEDIA-MIB-TC SnmpAdminString FROM SNMP-FRAMEWORK-MIB isdnSignalingEntry FROM ISDN-MIB frAtmIwfConnectionEntry FROM FR-ATM-PVC-SERVICE-IWF-MIB hdsl2ShdslEndpointCurrEntry, hdsl2ShdslInvIndex, hdsl2ShdslEndpointSide, hdsl2ShdslSpanConfProfileEntry FROM HDSL2-SHDSL-LINE-MIB IfIndexType FROM RFC1381-MIB; -- Some MIB compilers need those two lines: -- enterprises OBJECT IDENTIFIER ::= -- { iso org(3) dod(6) internet(1) private(4) 1 } rad MODULE-IDENTITY LAST-UPDATED "200210011220Z" ORGANIZATION "RAD MIB" CONTACT-INFO " Smadar Tauber Postal: RAD Data Communications LTD. 24 Raoul Wallenberg St. (Ziv-Towers) Tel-Aviv, Israel Tel: +972-3-765-9973 Fax: +972-3-644-0930 E-mail: smadar_t@rad.co.il" DESCRIPTION "RAD MIB, version 485." REVISION "200202191210Z" DESCRIPTION "RAD MIB, version 480." ::= { enterprises 164 } -- rad OBJECT IDENTIFIER ::= { enterprises 164 } radTokenRing OBJECT IDENTIFIER ::= { rad 1 } -- RAD Token Ring tree radFddi OBJECT IDENTIFIER ::= { rad 2 } -- rad FDDI Tree radWan OBJECT IDENTIFIER ::= { rad 3 } -- RAD WAN radBridges OBJECT IDENTIFIER ::= {rad 4 } radConverters OBJECT IDENTIFIER ::= { rad 5 } -- RAD Converters products' tree radGen OBJECT IDENTIFIER ::= { rad 6} -- General information radStkHub OBJECT IDENTIFIER ::= { rad 7 } -- stackable products radPS OBJECT IDENTIFIER ::= { rad 8 } -- Packet Switch radRouter OBJECT IDENTIFIER ::= { rad 11 } -- Routers rtrBridge OBJECT IDENTIFIER ::= { radRouter 7 } radAtm OBJECT IDENTIFIER ::= { rad 12 } -- ATM Products radExperimental OBJECT IDENTIFIER ::= { rad 20 } -- Drafts that have no MIB tree yet -- igmpStdMIB MODULE-IDENTITY ::= { radExperimental 1 } -- apsMIB OBJECT IDENTIFIER ::= { radExperimental 2 } -- atmApsMIB OBJECT IDENTIFIER ::= { radExperimental 3 } -- frsldMIB OBJECT IDENTIFIER ::= { radExperimental 4 } -- cpIwfMIB OBJECT IDENTIFIER ::= { radExperimental 5 } -- hdsl2ShdslMIB OBJECT IDENTIFIER ::= { radExperimental 6 } MacAddress ::= OCTET STRING (SIZE(6)) TimeSlots ::= OCTET STRING (SIZE(4)) -- -- file :v:\doc\rdv\mib\ver485\radgen.txt -- --First Version Date: 25.01.99 --By: Orly Nicklass --File: radgen.txt --Last Update: 21-Aug-2002 by Yig'al Hachmon systems OBJECT IDENTIFIER ::= { radGen 1} -- list of RAD products radSysTR OBJECT IDENTIFIER ::= { systems 1 } -- RAD Token Ring radRADring OBJECT IDENTIFIER ::= { radSysTR 1 } radTMA OBJECT IDENTIFIER ::= { radSysTR 2 } radRingMonitor OBJECT IDENTIFIER ::= { radSysTR 3 } radSysFddi OBJECT IDENTIFIER ::= { systems 2 } -- RAD Fddi radFDX100 OBJECT IDENTIFIER ::= { radSysFddi 1 } -- RAD Fddi radSysWan OBJECT IDENTIFIER ::= { systems 3 } -- RAD Wan products radSysWanEvents OBJECT-IDENTITY STATUS current DESCRIPTION "The events for RAD Wan products." ::= { radSysWan 0 } radMP2100 OBJECT IDENTIFIER ::= { radSysWan 1 } radMP2104 OBJECT IDENTIFIER ::= { radSysWan 2 } radMP2100B OBJECT IDENTIFIER ::= { radSysWan 3 } radMP2100F OBJECT IDENTIFIER ::= { radSysWan 4 } radMP2100H OBJECT IDENTIFIER ::= { radSysWan 5 } radMP2104H OBJECT IDENTIFIER ::= { radSysWan 6 } radMP2200B OBJECT IDENTIFIER ::= { radSysWan 7 } radMP2200F OBJECT IDENTIFIER ::= { radSysWan 8 } radMX3000 OBJECT IDENTIFIER ::= { radSysWan 9 } radMX3004 OBJECT IDENTIFIER ::= { radSysWan 10 } radMX30 OBJECT IDENTIFIER ::= { radSysWan 11 } radMX300 OBJECT IDENTIFIER ::= { radSysWan 12 } radVOIP OBJECT IDENTIFIER ::= { radSysWan 13 } radKM2100 OBJECT IDENTIFIER ::= { radSysWan 15 } radKM2104 OBJECT IDENTIFIER ::= { radSysWan 16 } radDXC30 OBJECT IDENTIFIER ::= { radSysWan 20 } radDXC10A OBJECT IDENTIFIER ::= { radSysWan 21 } radDXC8R OBJECT IDENTIFIER ::= { radSysWan 22 } radDXC30E OBJECT IDENTIFIER ::= { radSysWan 23 } radDXC3000 OBJECT IDENTIFIER ::= { radSysWan 24 } radDXC8RNew OBJECT IDENTIFIER ::= { radSysWan 25 } radFcdE1L OBJECT IDENTIFIER ::= { radSysWan 29 } radFcdT1 OBJECT IDENTIFIER ::= { radSysWan 30 } radFcdE1 OBJECT IDENTIFIER ::= { radSysWan 31 } radFcdE1I OBJECT IDENTIFIER ::= { radSysWan 32 } radFcdT1M OBJECT IDENTIFIER ::= { radSysWan 33 } radFcdE1M OBJECT IDENTIFIER ::= { radSysWan 34 } radFcdIP OBJECT IDENTIFIER ::= { radSysWan 35} radFcdT1A OBJECT IDENTIFIER ::= { radSysWan 36 } radFcdE1A OBJECT IDENTIFIER ::= { radSysWan 37 } radFcdW OBJECT IDENTIFIER ::= { radSysWan 38 } radFcdSTM OBJECT IDENTIFIER ::= { radSysWan 39 } radHtuE1Sa OBJECT IDENTIFIER ::= { radSysWan 40 } radHtuE1 OBJECT IDENTIFIER ::= { radSysWan 41 } --card radHtu2Sa OBJECT IDENTIFIER ::= { radSysWan 42 } radHtu2 OBJECT IDENTIFIER ::= { radSysWan 43 } --card radAsmi450R768Sa OBJECT IDENTIFIER ::= { radSysWan 44 } radAsmi450R768 OBJECT IDENTIFIER ::= { radSysWan 45 } --card radAsmi450R1152Sa OBJECT IDENTIFIER ::= { radSysWan 46 } radAsmi450R1152 OBJECT IDENTIFIER ::= { radSysWan 47 } --card radLrs12F OBJECT IDENTIFIER ::= { radSysWan 48 } radLrs12B OBJECT IDENTIFIER ::= { radSysWan 49 } radLrs52 OBJECT IDENTIFIER ::= { radSysWan 50 } radHcdE1Sa OBJECT IDENTIFIER ::= { radSysWan 51 } radHcdE1 OBJECT IDENTIFIER ::= { radSysWan 52 } --card radHtuT1Sa OBJECT IDENTIFIER ::= { radSysWan 53 } radHtuT1 OBJECT IDENTIFIER ::= { radSysWan 54 } --card radOptimux4E1 OBJECT IDENTIFIER ::= { radSysWan 55 } radOptimux4T1 OBJECT IDENTIFIER ::= { radSysWan 56 } radOptimuxXLE1 OBJECT IDENTIFIER ::= { radSysWan 57 } radOptimuxXLT1 OBJECT IDENTIFIER ::= { radSysWan 58 } radOptimuxXL16E1 OBJECT IDENTIFIER ::= { radSysWan 59 } radImx64 OBJECT IDENTIFIER ::= { radSysWan 60 } radImx6L OBJECT IDENTIFIER ::= { radSysWan 61 } radImx2 OBJECT IDENTIFIER ::= { radSysWan 62 } radImx4T1 OBJECT IDENTIFIER ::= { radSysWan 63 } radImx4E1 OBJECT IDENTIFIER ::= { radSysWan 64 } radImx2T1E1 OBJECT IDENTIFIER ::= { radSysWan 65 } radImxi4 OBJECT IDENTIFIER ::= { radSysWan 66 } radOptimux4T1L OBJECT IDENTIFIER ::= { radSysWan 68 } --SA Low Cost radOptimux4E1L OBJECT IDENTIFIER ::= { radSysWan 69 } --SA Low Cost radHtuE1SaV2 OBJECT IDENTIFIER ::= { radSysWan 70 } radHtuE1V2 OBJECT IDENTIFIER ::= { radSysWan 71 } --card radFomiE3 OBJECT IDENTIFIER ::= { radSysWan 72 } --card radFomiT3 OBJECT IDENTIFIER ::= { radSysWan 73 } --card radOpt4E1C OBJECT IDENTIFIER ::= { radSysWan 74 } --card radOpt4T1C OBJECT IDENTIFIER ::= { radSysWan 75 } --card radPrbiE3 OBJECT IDENTIFIER ::= { radSysWan 76 } --SA radPrbiT3 OBJECT IDENTIFIER ::= { radSysWan 77 } --SA radHcd4Sa OBJECT IDENTIFIER ::= { radSysWan 78 } --SA radOptimuxT3 OBJECT IDENTIFIER ::= { radSysWan 79 } --SA radFRmon OBJECT IDENTIFIER ::= { radSysWan 80 } radIpMux4 OBJECT IDENTIFIER ::= { radSysWan 81 } radIpMux1 OBJECT IDENTIFIER ::= { radSysWan 82 } radIpMux16 OBJECT IDENTIFIER ::= { radSysWan 83 } radIpMux1E OBJECT IDENTIFIER ::= { radSysWan 84 } radVmux2100 OBJECT IDENTIFIER ::= { radSysWan 85 } -- reserved for radMP104 OBJECT IDENTIFIER ::= { radSysWan 86 } -- reserved for radMP204 OBJECT IDENTIFIER ::= { radSysWan 87 } radVmux110 OBJECT IDENTIFIER ::= { radSysWan 88 } -- reserved for radFcd155 OBJECT IDENTIFIER ::= { radSysWan 90 } radIpMux8 OBJECT IDENTIFIER ::= { radSysWan 91 } radSysBRG OBJECT IDENTIFIER ::= { systems 4 } -- RAD Bridges products radTRE1 OBJECT IDENTIFIER ::= { radSysBRG 1 } -- RAD Bridges products radTRE1D OBJECT IDENTIFIER ::= { radSysBRG 2 } -- RAD Bridges products radTRE8 OBJECT IDENTIFIER ::= { radSysBRG 3 } -- RAD Bridges products radTRE8D OBJECT IDENTIFIER ::= { radSysBRG 4 } -- RAD Bridges products radMBE1 OBJECT IDENTIFIER ::= { radSysBRG 5 } -- RAD Bridges products radMBE1D OBJECT IDENTIFIER ::= { radSysBRG 6 } -- RAD Bridges products radMBE8 OBJECT IDENTIFIER ::= { radSysBRG 7 } -- RAD Bridges products radMBE8D OBJECT IDENTIFIER ::= { radSysBRG 8 } -- RAD Bridges products radMLBT OBJECT IDENTIFIER ::= { radSysBRG 9 } -- RAD Bridges products radFEB4DAS OBJECT IDENTIFIER ::= { radSysBRG 10 } -- RAD Bridges products radTrimBrg10 OBJECT IDENTIFIER ::= { radSysBRG 11 } -- RAD Bridges products radTrimBrg16 OBJECT IDENTIFIER ::= { radSysBRG 12 } -- RAD Bridges products radRRTRE8 OBJECT IDENTIFIER ::= { radSysBRG 13 } -- RAD Bridges products radRRTRE8D OBJECT IDENTIFIER ::= { radSysBRG 14 } -- RAD Bridges products radRRMLBT OBJECT IDENTIFIER ::= { radSysBRG 15 } -- RAD Bridges products radRRMLBTF OBJECT IDENTIFIER ::= { radSysBRG 16 } -- RAD Bridges products radRRTRE1D OBJECT IDENTIFIER ::= { radSysBRG 17 } -- RAD Bridges products radTRERAS OBJECT IDENTIFIER ::= { radSysBRG 18 } -- RAD Bridges products radTRERASa OBJECT IDENTIFIER ::= { radSysBRG 19 } -- RAD Bridges products radMBERAS OBJECT IDENTIFIER ::= { radSysBRG 20 } -- RAD Bridges products radMBERASa OBJECT IDENTIFIER ::= { radSysBRG 21 } -- RAD Bridges products radFEB4FDX OBJECT IDENTIFIER ::= { radSysBRG 22 } -- RAD Bridges products radFEB4SAS OBJECT IDENTIFIER ::= { radSysBRG 23 } -- RAD Bridges products radRRFTBDAS OBJECT IDENTIFIER ::= { radSysBRG 24 } -- RAD Bridges products radRRFTBSAS OBJECT IDENTIFIER ::= { radSysBRG 25 } -- RAD Bridges products radFTBDAS OBJECT IDENTIFIER ::= { radSysBRG 26 } -- RAD Bridges products radFTBSAS OBJECT IDENTIFIER ::= { radSysBRG 27 } -- RAD Bridges products radFastWay100 OBJECT IDENTIFIER ::= { radSysBRG 28 } -- RAD Bridges products radSysCnvrtr OBJECT IDENTIFIER ::= { systems 5 } -- RAD Converters products radSTC1 OBJECT IDENTIFIER ::= { radSysCnvrtr 1 } -- RAD Converters products radSTC2 OBJECT IDENTIFIER ::= { radSysCnvrtr 3 } -- RAD Converters products radSTC1UDP OBJECT IDENTIFIER ::= { radSysCnvrtr 4 } -- RAD Converters products radSTC2UDP OBJECT IDENTIFIER ::= { radSysCnvrtr 6 } -- RAD Converters products radFTC1 OBJECT IDENTIFIER ::= { radSysCnvrtr 10 } -- RAD Converters products radFTC2 OBJECT IDENTIFIER ::= { radSysCnvrtr 12 } -- RAD Converters products radFTC1UDP OBJECT IDENTIFIER ::= { radSysCnvrtr 13 } -- RAD Converters products radFTC2UDP OBJECT IDENTIFIER ::= { radSysCnvrtr 15 } -- RAD Converters products radSEC1 OBJECT IDENTIFIER ::= { radSysCnvrtr 20 } -- RAD Converters products radSEC2 OBJECT IDENTIFIER ::= { radSysCnvrtr 22 } -- RAD Converters products radSEC1UDP OBJECT IDENTIFIER ::= { radSysCnvrtr 23 } -- RAD Converters products radSEC2UDP OBJECT IDENTIFIER ::= { radSysCnvrtr 25 } -- RAD Converters products radFEC1 OBJECT IDENTIFIER ::= { radSysCnvrtr 30 } -- RAD Converters products radFEC2 OBJECT IDENTIFIER ::= { radSysCnvrtr 32 } -- RAD Converters products radFEC1UDP OBJECT IDENTIFIER ::= { radSysCnvrtr 33 } -- RAD Converters products radFEC2UDP OBJECT IDENTIFIER ::= { radSysCnvrtr 35 } -- RAD Converters products radSysStkHub OBJECT IDENTIFIER ::= { systems 7 } -- RAD Stackable products radRBHE OBJECT IDENTIFIER ::= { radSysStkHub 1 } -- RAD Stackable products radRBHT OBJECT IDENTIFIER ::= { radSysStkHub 2 } -- RAD Stackable products radRBHEEvents OBJECT-IDENTITY STATUS current DESCRIPTION "The events for RAD Stackable products." ::= { radRBHE 0 } radRBHTEvents OBJECT-IDENTITY STATUS current DESCRIPTION "The events for RAD Stackable products." ::= { radRBHT 0 } radETS4fddiDAS OBJECT IDENTIFIER ::= { radSysStkHub 3 } -- RAD Stackable products radETS4fddiSAS OBJECT IDENTIFIER ::= { radSysStkHub 4 } -- RAD Stackable products radSAHEMX OBJECT IDENTIFIER ::= { radSysStkHub 5 } -- RAD Stackable products radSAHTM OBJECT IDENTIFIER ::= { radSysStkHub 6 } -- RAD Stackable products radETS4 OBJECT IDENTIFIER ::= { radSysStkHub 7 } -- RAD Stackable products radSAHEMU OBJECT IDENTIFIER ::= { radSysStkHub 8 } -- RAD Stackable products unknown OBJECT IDENTIFIER ::= { radSysStkHub 9 } -- RAD Stackable products radSAH16Eint OBJECT IDENTIFIER ::= { radSysStkHub 10 } -- RAD Stackable products radSAH16Tint OBJECT IDENTIFIER ::= { radSysStkHub 11 } -- RAD Stackable products radSAH16Eext OBJECT IDENTIFIER ::= { radSysStkHub 12 } -- RAD Stackable products radSAH16Text OBJECT IDENTIFIER ::= { radSysStkHub 13 } -- RAD Stackable products radSysPS OBJECT IDENTIFIER ::= { systems 8 } -- RAD Packet Switch (PS) products radSysPSEvents OBJECT-IDENTITY STATUS current DESCRIPTION "The events for RAD Packet Switch (PS) products." ::= { radSysPS 0 } radSPS2 OBJECT IDENTIFIER ::= { radSysPS 1 } -- RAD Packet Switch (PS) products radSPS3 OBJECT IDENTIFIER ::= { radSysPS 2 } -- RAD Packet Switch (PS) products radSPS6 OBJECT IDENTIFIER ::= { radSysPS 3 } -- RAD Packet Switch (PS) products radSPS9 OBJECT IDENTIFIER ::= { radSysPS 4 } -- RAD Packet Switch (PS) products radSPS12 OBJECT IDENTIFIER ::= { radSysPS 5 } -- RAD Packet Switch (PS) products radAPD2 OBJECT IDENTIFIER ::= { radSysPS 6 } -- RAD Packet Switch (PS) products radAPD8 OBJECT IDENTIFIER ::= { radSysPS 7 } -- RAD Packet Switch (PS) products radAPS8 OBJECT IDENTIFIER ::= { radSysPS 8 } -- RAD Packet Switch (PS) products radAPS16 OBJECT IDENTIFIER ::= { radSysPS 9 } -- RAD Packet Switch (PS) products radAPS24 OBJECT IDENTIFIER ::= { radSysPS 10 } -- RAD Packet Switch (PS) products radSPS3S OBJECT IDENTIFIER ::= { radSysPS 11} -- RAD Packet Switch (PS) products radFPS8 OBJECT IDENTIFIER ::= { radSysPS 12} -- RAD Packet Switch (PS) products radFPS12 OBJECT IDENTIFIER ::= { radSysPS 13} -- RAD Packet Switch (PS) products radSPS3ScSL OBJECT IDENTIFIER ::= { radSysPS 14} -- RAD Packet Switch (PS) products radSPS3Sc2S OBJECT IDENTIFIER ::= { radSysPS 15} -- RAD Packet Switch (PS) products radFPS8c OBJECT IDENTIFIER ::= { radSysPS 16} -- RAD Packet Switch (PS) products radFPS4 OBJECT IDENTIFIER ::= { radSysPS 17} -- RAD Packet Switch (PS) products radSysEth OBJECT IDENTIFIER ::= { systems 9 } -- RAD Ethernet products radEP8T OBJECT IDENTIFIER ::= {radSysEth 1} -- RAD Ethernet products radEP4TAUI OBJECT IDENTIFIER ::= {radSysEth 2} -- RAD Ethernet products radEP4T2FL OBJECT IDENTIFIER ::= {radSysEth 3} -- RAD Ethernet products radEP4TFL OBJECT IDENTIFIER ::= {radSysEth 4} -- RAD Ethernet products radEP4FL OBJECT IDENTIFIER ::= {radSysEth 5} -- RAD Ethernet products radEPR8T OBJECT IDENTIFIER ::= {radSysEth 7} -- RAD Ethernet products radEPR4TAUI OBJECT IDENTIFIER ::= {radSysEth 8} -- RAD Ethernet products radEPR4T2FL OBJECT IDENTIFIER ::= {radSysEth 9} -- RAD Ethernet products radEPR4TFL OBJECT IDENTIFIER ::= {radSysEth 10} -- RAD Ethernet products radEPR4FL OBJECT IDENTIFIER ::= {radSysEth 11} -- RAD Ethernet products radSysRtr OBJECT IDENTIFIER ::= { systems 11 } -- RAD Router products radSysRtrEvents OBJECT-IDENTITY STATUS current DESCRIPTION "The events for RAD Router products." ::= { radSysRtr 0 } radRTED OBJECT IDENTIFIER ::= {radSysRtr 1} -- RAD Router products radRTEM OBJECT IDENTIFIER ::= {radSysRtr 2} -- RAD Router products radRTEC OBJECT IDENTIFIER ::= {radSysRtr 3} -- RAD Router products radWebRanger OBJECT IDENTIFIER ::= {radSysRtr 4} -- RAD Router products radTinyRouter OBJECT IDENTIFIER ::= {radSysRtr 5} -- RAD Router products radLA240 OBJECT IDENTIFIER ::= {radSysRtr 6} -- RAD Router products radSuperLan OBJECT IDENTIFIER ::= {radSysRtr 7} -- RAD Router products (LA-240) radLA240I OBJECT IDENTIFIER ::= {radSysRtr 8} -- RAD Router products radFcdIsdn OBJECT IDENTIFIER ::= {radSysRtr 9} -- RAD Router products radEFcdIp OBJECT IDENTIFIER ::= {radSysRtr 10} -- RAD Router products (FCD-IP/D) radFcdIpD OBJECT IDENTIFIER ::= {radSysRtr 11} -- RAD Router products radFcdIpM OBJECT IDENTIFIER ::= {radSysRtr 12} -- RAD Router products (LA-240) radSysAtm OBJECT IDENTIFIER ::= { systems 12 } -- RAD ATM products radSysAtmEvents OBJECT-IDENTITY STATUS current DESCRIPTION "The events for RAD ATM products." ::= { radSysAtm 0 } radStarSwitch OBJECT IDENTIFIER ::= {radSysAtm 1} --RAD StartSwitch products radStarSwitchATM25 OBJECT IDENTIFIER ::= {radStarSwitch 1} --RAD StartSwitch products radStarSwitchATM25L OBJECT IDENTIFIER ::= {radStarSwitch 2} --RAD StartSwitch products radStarSwitchATM155 OBJECT IDENTIFIER ::= {radStarSwitch 3} --RAD StartSwitch products radAtmCsuDsu OBJECT IDENTIFIER ::= {radSysAtm 2} --RAD CSU/DSU products radAmcdE1 OBJECT IDENTIFIER ::= {radAtmCsuDsu 1} -- RAD CSU/DSU products radAmcdT1 OBJECT IDENTIFIER ::= {radAtmCsuDsu 2} -- RAD CSU/DSU products radAce20E OBJECT IDENTIFIER ::= {radAtmCsuDsu 3} -- RAD CSU/DSU products radAce20T OBJECT IDENTIFIER ::= {radAtmCsuDsu 4} -- RAD CSU/DSU products radAce2005 OBJECT IDENTIFIER ::= { radAtmCsuDsu 5} -- RAD ACE2005 radAce2002 OBJECT IDENTIFIER ::= { radAtmCsuDsu 6} -- RAD ACE2002 radAce2002E OBJECT IDENTIFIER ::= { radAtmCsuDsu 7} -- RAD ACE2002E radAce2E OBJECT IDENTIFIER ::= {radAtmCsuDsu 8} -- RAD CSU/DSU products radAce2T OBJECT IDENTIFIER ::= {radAtmCsuDsu 9} -- RAD CSU/DSU products radMlAtmE1 OBJECT IDENTIFIER ::= {radAtmCsuDsu 10} -- RAD ATM Piggy radMlAtmT1 OBJECT IDENTIFIER ::= {radAtmCsuDsu 11} -- RAD ATM Piggy radAmc102 OBJECT IDENTIFIER ::= {radAtmCsuDsu 12} -- RAD AMC102 radAmc102c OBJECT IDENTIFIER ::= {radAtmCsuDsu 13} -- RAD AMC102 CARD radAce202 OBJECT IDENTIFIER ::= { radAtmCsuDsu 14} -- RAD ACE202 radAce OBJECT IDENTIFIER ::= {radSysAtm 3} --RAD ACE products radAce101 OBJECT IDENTIFIER ::= {radAce 1} -- RAD ACE101 radAce102 OBJECT IDENTIFIER ::= {radAce 2} -- RAD ACE102 radAce50 OBJECT IDENTIFIER ::= {radAce 3} -- RAD ACE50 radSysLA OBJECT IDENTIFIER ::= {systems 13} --RAD IAD (Integrated Access Device) products radLA140 OBJECT IDENTIFIER ::= {radSysLA 1} -- RAD LA-140 radLA110 OBJECT IDENTIFIER ::= {radSysLA 2} -- RAD LA-110 radLA104 OBJECT IDENTIFIER ::= {radSysLA 3} -- RAD LA-104 (LA-110 with IMA) radSysTerminal OBJECT IDENTIFIER ::= {systems 100} --RAD Terminal Meta-MIB; -- no objects should be added to this branch in RAD MIB. agnt OBJECT IDENTIFIER ::= { radGen 2} -- agent general tree -- Agent General agnHwVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ASCII string for description and display of the agent hardware version, as it is known by the agent software.The user can update the version upon request when he changes components in the agent's module " ::= { agnt 1 } agnTrapMask OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of this attribute determines the type of traps the agent should mask and not send to the management console. The value is differently determined for different products. There are mainly two methods: - an integer number, specifying the traps' severity. - a sum of 2**n, where n is a bit assigned to a certain masked trap group. User should consult the product specification, to find out the method employed." ::= { agnt 2 } agnTrapValue OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The value of the trap decoded in internal RAD format. Full description is given in the Trap definition file" ::= {agnt 3} agnChangeCnt OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of changes in system configuration that were reported to the manager since last cold start" ::= {agnt 4 } agnSpecific OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION " Object identifier of entity containing additional information regarding this instance." ::= { agnt 5} agnConfigMsg OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Full configuration message coded in internal RAD application format. This entry describes agent's configuration. For MP-2200 R3, this object describes agent's support of the V5.1 feature: 1 octet ; bit 0 (LSB). '1' - V5.1 feature is supported '0' - V5.1 feature is not supported." ::= { agnt 6 } -- Manager table to record all IP addresses mngTrapIpTable OBJECT-TYPE SYNTAX SEQUENCE OF MngEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table indicates the destination address of the traps. Internally it will be limited to ten addresses. " ::= { agnt 7 } mngEntry OBJECT-TYPE SYNTAX MngEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { mngID } ::= { mngTrapIpTable 1 } MngEntry ::= SEQUENCE { mngID Integer32, mngIP IpAddress, mngIPMask IpAddress, mngTrapMask Integer32 } mngID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " This value indicates an index of a specific IP address" ::= { mngEntry 1 } mngIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "This value indicates the destination address of the traps. IP 0.0.0.0 removes the entry. " ::= { mngEntry 2 } mngIPMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This value indicates the mask of the destination addresses of the traps. " ::= { mngEntry 3 } mngTrapMask OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of this attribute determines the type of traps the agent should mask and not send to this NMS. The value is differently determined for different products. There are mainly two methods: - an integer number, specifying the traps' severity. - a sum of 2**n, where n is a bit assigned to a certain masked trap group. User should consult the product specification, to find out the method employed." ::= { mngEntry 4 } agnIndication OBJECT-TYPE SYNTAX INTEGER { faulty (1), -- =major warning (2), normal (3), -- off minor (4), major (5), event (6), critical(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Attribute describing the state of the entity the agent is responsible for. In case of a modular entity, the value of this attribute will be according to the component which is in the worst state. The order of severity (from top to bottom) is: critical-> major (or faulty)-> minor-> event-> warning-> normal (off)." ::= { agnt 8 } agnMonitorModeCmd OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), off(2), on(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to ON, will enforce the agent to change its mode of operation to Monitor Mode" ::= {agnt 9} agnLed OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This entry specifies the LEDs status of the agent module . Each led will be represented by 4 bits where the first 2 bits (left) will specify the status : (00=NA, 01=OFF, 10=ON, 11=BLINK), and the next two bits (right) will specify the color : (00=GREEN, 01=RED, 10=YELLOW, 11=GRAY)" ::= {agnt 10} trapTable OBJECT-TYPE SYNTAX SEQUENCE OF TrapEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table includes the last few traps generated by the agent, for future retrieval. The table has a limited capacity. If traps are not retrieved in proper time, they will be over-written by new traps " ::= {agnt 11} trapEntry OBJECT-TYPE SYNTAX TrapEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { trapID } ::= { trapTable 1 } TrapEntry ::= SEQUENCE { trapID Integer32, trapVal DisplayString, trapTimeSinceOccurrence TimeTicks } trapID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " This value indicates an index of a specific trap " ::= { trapEntry 1 } trapVal OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This value is the actual ASCII description of the trap. " ::= { trapEntry 2 } trapTimeSinceOccurrence OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "This value indicates the amount of time passed since the occurrence of the event that trigger this trap. " ::= { trapEntry 3 } fileTransfer OBJECT IDENTIFIER ::= { agnt 12 } fileServerIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The IP address of the server from which the file is loaded " ::= { fileTransfer 1 } fileName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The name of the file to be loaded. For protection, read returns NULL. " ::= { fileTransfer 2 } fileTransCmd OBJECT-TYPE SYNTAX INTEGER { swDwnLoad (1), configDwnLoad (2), configUpLoad (3), coProcDwnLoad (4), stateUpLoad (5), dwnLoadUserFile (6), upLoadUserFile (7), swDwnLoadAndReset (8), noOp (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "The command to be executed on fileName at fileServerIP." ::= { fileTransfer 3 } -- tftp group tftpRetryTimeOut OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " General Retransmission time-out value (seconds) " -- DEFVAL { 15 } ::= { fileTransfer 4 } tftpTotalTimeOut OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Total Retransmission time-out value (seconds) " -- DEFVAL { 60 } ::= { fileTransfer 5 } tftpStatus OBJECT-TYPE SYNTAX INTEGER { noOp(2), connecting(3), transferringData(4), endedTimeOut(5), endedOk(6), error(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "Status of tftp session. When a session ended with success, the tftpStatus should be endedOk(6). Before restarting a tftp session, the NMS should set the tftpStatus to noOp(2). That's the reason of MAX-ACCESS read-write to this field." DEFVAL { noOp} ::= { fileTransfer 6 } tftpError OBJECT-TYPE SYNTAX OCTET STRING ( SIZE(2) ) MAX-ACCESS read-only STATUS current DESCRIPTION " The MSB represents the standard error code. The LSB represents the private error code. 0x0000 is No Error 0x0100 is File Not Found 0x0400 is Illegal TFTP operation 0x0500 is Unknown transfer ID 0x0001 is Server Overflow 0x0002 is No empty UDP port 0x0003 is No empty connection 0x0004 is Illegal File Mode 0x0007 is Illegal PDU size " DEFVAL { '0000'h } ::= { fileTransfer 7 } fileTransferToSubSystems OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION " This object represents the sub-systems the fileTransCmd refers to. It should be used when a system is divided to sub-systems and each sub-system (or part of them) can have a different SW/Configuration. Each bit of this object will represent one of the sub-systems. Bit='1' - APPLY to respective sub-system Bit='0' - DO NOT APPLY to respective sub-system For the meaning of each bit, see product's specification. User will select the sub-systems envolved by filling-in the bits that represent these sub-systems. In this case, the file represented by 'fileName' will include several parts, each representing one of the sub-systems. The agent will refer only to the part/s indicated by this object. 0 Octet Strings = not applicable DEFVAL = 0h for the products that support this object." ::= { fileTransfer 8 } fileNameWithinProduct OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The file name used by the product within the product file system." ::= { fileTransfer 9 } --Internal SW Download table intSwdlTable OBJECT-TYPE SYNTAX SEQUENCE OF IntSwdlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This parameters table is for internal Software down load. It also includes data about all files contained in the Object from which down-load is performed." ::= { fileTransfer 10 } intSwdlEntry OBJECT-TYPE SYNTAX IntSwdlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {intSwdlObjIdx, intSwdlFileIdx } ::= { intSwdlTable 1} IntSwdlEntry ::= SEQUENCE { intSwdlObjIdx Integer32, intSwdlFileIdx Integer32, intSwdlFileName DisplayString, intSwdlFileSwVer DisplayString, intSwdlSwDate DisplayString, intSwdlSize DisplayString, intSwdlCmd INTEGER, intSwdlToSubSystem OCTET STRING } intSwdlObjIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the object from which down-load is performed." ::= {intSwdlEntry 1} intSwdlFileIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the files included in intSwdlObjIdx. One of these files can be selected to be internally downloaded." ::= {intSwdlEntry 2} intSwdlFileName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the file." ::= {intSwdlEntry 3} intSwdlFileSwVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The software version of the file." ::= {intSwdlEntry 4} intSwdlSwDate OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The software version date of the file." ::= {intSwdlEntry 5} intSwdlSize OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The size of the file." ::= {intSwdlEntry 6} intSwdlCmd OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), off (2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The command to down-load a SW file to an object. The Agent will change the value of this MIB object to off(2) automatically, after accepting the command." ::= {intSwdlEntry 7} intSwdlToSubSystem OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION " This object defines the subsystem for download. Bit='1'- APPLY to respective sub system. Bit='0'- DO NOT APPLY to respective sub system. For more details see product specification. For every octet bit0=LSB, bit7=MSB" ::= { intSwdlEntry 8 } --SW Download Status table swdlStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF SwdlStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This parameters table is for software download status. It also includes data about the files down-loaded or attempted to be down-loaded." ::= { fileTransfer 11 } swdlStatusEntry OBJECT-TYPE SYNTAX SwdlStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {swdlStatusTypeIdx, swdlStatusIdx } ::= { swdlStatusTable 1} SwdlStatusEntry ::= SEQUENCE { swdlStatusTypeIdx Integer32, swdlStatusIdx Integer32, swdlStatusFileName DisplayString, swdlStatusSlot DisplayString, swdlStatusSubSystem DisplayString, swdlStatusStatus Integer32, swdlStatusTime DisplayString } swdlStatusTypeIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the down-load type (e.g. external (1) or internal (2))." ::= {swdlStatusEntry 1} swdlStatusIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the status rows." ::= {swdlStatusEntry 2} swdlStatusFileName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the file." ::= {swdlStatusEntry 3} swdlStatusSlot OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The slot of the updated (or attempted to be updated) object." ::= {swdlStatusEntry 4} swdlStatusSubSystem OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The subsystem that updated (or attempted to be updated)." ::= {swdlStatusEntry 5} swdlStatusStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the down load process. Value: Fail (2), OK (3), InProcess (4)." ::= {swdlStatusEntry 6} swdlStatusTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This MIB parameter indicates the time SW download was finished. The format shuld be YYYY-MM-DD, hh:mm:ss" ::= {swdlStatusEntry 7} clearDwldStatusLog OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object clears the status log. Value: off(2), external(3), internal(4) The Agent will change the value of this MIB object to off(2) automatically, after accepting the command ." ::= { fileTransfer 12 } systemReset OBJECT-TYPE SYNTAX INTEGER { off (2), on (3), --HW resetConfig (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Reset action to be performed on the system." ::= { agnt 13 } systemTiming OBJECT IDENTIFIER ::= { agnt 14 } systemDate OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "System date." ::= { systemTiming 1 } systemTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "System time." ::= { systemTiming 2 } systemPort OBJECT IDENTIFIER ::= { agnt 15 } physicalConnectorTable OBJECT-TYPE SYNTAX SEQUENCE OF PhysicalConnectorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table includes the connector type of ports or interfaces." ::= {systemPort 1} physicalConnectorEntry OBJECT-TYPE SYNTAX PhysicalConnectorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {portIdx} ::= { physicalConnectorTable 1 } PhysicalConnectorEntry ::= SEQUENCE { portIdx Integer32, physicalConnector INTEGER, portOptWaveLength INTEGER, portOptMode INTEGER } portIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object is an index of the specific port or interface. For a port, the index will be as agreed between agent and application. For an interface, ifIndex may be used." ::= { physicalConnectorEntry 1 } physicalConnector OBJECT-TYPE SYNTAX INTEGER { other (1), v35 (2), --34 pin female rs530 (3), --DB25 x21 (4), --DB15 bnc (5), utp (6), --RJ45 aui (7), rs422 (8), --DB25 crossUtp (9), --RJ45 rj45 (10), v24 (11), --DB25 g703 (12), --TB5 termBlock3AndRj45 (13), terminalBlock3 (14), terminalBlock5 (15), terminalBlock7 (16), db25 (17), db15 (18), rj45ethernet (19), termBlock5AndRj45 (20), db9 (21), g703E1 (22), --BNC-RJ45-BNC g703E1-LTU (23), --BNC-RJ45-BNC sc (24), --sc optical st (25), --st optical stl (26), fc (27), --fc optical tb5w (28), --Term-Block-5-Wire (for HCD) termBlock6AndRj45 (29), ethBnc (30), scsi26 (31), --SCSI with 26 pins eth4381 (32), --RJ45 with two embeded LEDs twoBnc (33), --Two BNC scsi50 (34), --SCSI with 50 pins twoMiniBnc (35), --Two mini BNC sf1 (36), --sf1=single fiber optical terminalBlock4 (37), sf2 (38), --sf2=single fiber optical db25Balanced (39), --DB25 Balanced v36 (40), block4W (41), --like in WR connector for Modems iripRj45 (42), irEthQRj45 (43), iripBnc (44), rs530WA (45), --rs530/IR that solves a wander problem for SDH network v35WA (46), --v35/IR that solves a wander problem for SDH network irEthQBnc (47), v35Db25 (48), --V.35 with connector DB25 rj11 (49), --Used for FXS & FXO mtrj (50), --optical lc (51), --optical terminalBlock2 (52), irEth10s100 (53), --IR-ETH 10/100 scsi68 (54), -- SCSI 68 pins sf3 (55), -- sf3=single fiber of sc optical fcLH (56), -- fc Long Haul none (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "The connector of the port/interface. other - none of the specified connectors none - no connector." ::= { physicalConnectorEntry 2 } portOptWaveLength OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), nm850(2), nm1300(3), nm1300Laser(4), nm1550Laser(5), nm1300LaserLH(6), nm1550LaserLH(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Wave Length of an Optical interface/port in [nm] and specification if Laser LH,Laser or LED. notApplicable - for non-optical ports." ::= { physicalConnectorEntry 3 } portOptMode OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), singleMode(2), multiMode(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Laser Mode of an Optical Laser interface/port. notApplicable - for non-Laser ports." ::= { physicalConnectorEntry 4 } prtSupervisory OBJECT IDENTIFIER ::= { systemPort 2 } prtSpTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtSpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= {prtSupervisory 1} prtSpEntry OBJECT-TYPE SYNTAX PrtSpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Supervisory port parameter table." INDEX {prtSupervisoryIndex } ::= { prtSpTable 1} PrtSpEntry ::= SEQUENCE { prtSupervisoryIndex Integer32, prtSupervisoryRate INTEGER, prtSupervisoryDataBits INTEGER, prtSupervisoryParity INTEGER, prtSupervisoryStopBits INTEGER, prtSupervisoryUsage INTEGER, prtSupervisoryInterface INTEGER, prtSupervisoryCTS INTEGER, prtSupervisoryDcdDelay INTEGER, prtSupervisoryDSR INTEGER, prtSupervisoryRoutProtocol INTEGER } prtSupervisoryIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The SP port index. The LS byte of the integer is the port index 1..255. The MS byte is different than 0 only if the port belongs to a module. In that case it is the module number." ::= { prtSpEntry 1} prtSupervisoryRate OBJECT-TYPE SYNTAX INTEGER { auto (1), s300bps (2), s1200bps (3), s2400bps (4), s4800bps (5), s9600bps (6), s19200bps (7), s38400bps (8), s57600bps (9), s115200bps (10) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the operation rate (speed) of the port. auto - automatic rate selection, by the agent." ::= { prtSpEntry 2} prtSupervisoryDataBits OBJECT-TYPE SYNTAX INTEGER { dataBits7 (1), dataBits8 (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the number of data bits in an async frame" ::= { prtSpEntry 3} prtSupervisoryParity OBJECT-TYPE SYNTAX INTEGER { none (1), odd (2), even (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the parity mode in an async frame" ::= { prtSpEntry 4} prtSupervisoryStopBits OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), stopBits1 (2), stopBits1dot5 (3), stopBits2 (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the parity mode in an async frame." ::= { prtSpEntry 5} prtSupervisoryUsage OBJECT-TYPE SYNTAX INTEGER { unknown (1), noUse (2), terminal(3), nmsSlip (4), nmsPpp (5), muxSlip (6), muxPpp (7), dialOut (8) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the usage of the SP port." ::= { prtSpEntry 6} prtSupervisoryInterface OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), dce (2), dte (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the supervisory port interface." ::= { prtSpEntry 7} prtSupervisoryCTS OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), on (2), --Old value for DCE. rts (3), --Old value for DCE dteWait (4), --DTE will wait for CTS to become active before transmit date. dteIgnore (5) --DTE will Ignore CTS signal and will transmit date anyway. } MAX-ACCESS read-write STATUS current DESCRIPTION "CTS line state." ::= { prtSpEntry 8} prtSupervisoryDcdDelay OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), d0 (2), d10 (3), d50 (4), d100 (5), d200 (6), d300 (7) } MAX-ACCESS read-write STATUS current DESCRIPTION "DCD delay in msec." ::= { prtSpEntry 9} prtSupervisoryDSR OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), on (2), dtr (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "DSR line state." ::= { prtSpEntry 10} prtSupervisoryRoutProtocol OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), none (2), proprietary (3), rip2 (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the routing protocol of the port. notApplicable - for DP." ::= { prtSpEntry 11} --Port Performance Data prtPerformance OBJECT IDENTIFIER ::= { systemPort 3 } prtPerfTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtPerfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table includes G.826 ports or interfaces." ::= {prtPerformance 1} prtPerfEntry OBJECT-TYPE SYNTAX PrtPerfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtPerfIdx, prtPerfPeriodRef} ::= { prtPerfTable 1 } PrtPerfEntry ::= SEQUENCE { prtPerfIdx Integer32, prtPerfPeriodRef INTEGER, prtPerfElapsedTime Integer32, prtPerfUAS Integer32, prtPerfES Integer32, prtPerfSES Integer32, prtPerfBBE Integer32, prtPerfBlocksPerSec Integer32, prtPerfTimeTag TimeTicks, prtPerfSaveAndResetCmd INTEGER } prtPerfIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object is an index of the specific port or interface. For a port, the index will be as agreed between agent and application. For an interface, ifIndex may be used." ::= { prtPerfEntry 1 } prtPerfPeriodRef OBJECT-TYPE SYNTAX INTEGER { currentPeriod (1), lastPeriod (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object is an index that specifies which period of time, the next 5 objects refer to. currentPeriod - the period since last prtPerfSaveAndResetCmd received or since Start-up (if no prtPerfSaveAndResetCmd was received since Start-up) until now. lastPeriod - the period between last two commands of prtPerfSaveAndResetCmd. - If only one command occured since Start-up: the period between Start-up and last command. - If no command occured since Start-up: this period will not actually exist. In this case, he following 5 objects will be 0." ::= { prtPerfEntry 2 } prtPerfElapsedTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Elapsed Time in seconds. - for prtPerfPeriodRef=currentPeriod: The period since last prtPerfSaveAndResetCmd received or since Start-up (if no prtPerfSaveAndResetCmd was received since Start-up) until now. - for prtPerfPeriodRef=lastPeriod: The value of prtPerfElapsedTime when last prtPerfSaveAndResetCmd was received." ::= { prtPerfEntry 3 } prtPerfUAS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of Unavailable Seconds for the reference period (prtPerfPeriodRef)." ::= { prtPerfEntry 4 } prtPerfES OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of Errored Seconds for the reference period (prtPerfPeriodRef)." ::= { prtPerfEntry 5 } prtPerfSES OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of Severely Errored Seconds for the reference period (prtPerfPeriodRef)." ::= { prtPerfEntry 6 } prtPerfBBE OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of Background Block (or Frame) Errors for the reference period (prtPerfPeriodRef)." ::= { prtPerfEntry 7 } prtPerfBlocksPerSec OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Blocks per second (or frames per second) of the port/interface indicated by portIdx. This object is constant for a certain port/interface. It is not affected by the prtPerfPeriodRef index." ::= { prtPerfEntry 8 } prtPerfTimeTag OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Time Tag of Last Period: sysUpTime when last prtPerfSaveAndResetCmd was executed. This object is applicable only for prtPerfPeriodRef=lastPeriod. For prtPerfPeriodRef=currentPeriod, the value will always be 0." ::= { prtPerfEntry 9 } prtPerfSaveAndResetCmd OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "A command per port/interface, to Save data of Current Period in Last Period data-set and start a new counting period for Current Period. This object is applicable only for prtPerfPeriodRef=currentPeriod. Setting this object to on(3) for prtPerfPeriodRef=last, will cause the agent to return: Bad Value response. When setting validly this object to on(3), agent will perform the required command and will reset automatically the value of this object to off(2). Setting this object to off(2), will do nothing." ::= { prtPerfEntry 10 } --Port Test Data prtTest OBJECT IDENTIFIER ::= { systemPort 4 } prtTestTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtTestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table includes test data for ports or interfaces." ::= {prtTest 1} prtTestEntry OBJECT-TYPE SYNTAX PrtTestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtTestIdx} ::= { prtTestTable 1 } PrtTestEntry ::= SEQUENCE { prtTestIdx Integer32, prtTestCmdAndStatus Integer32, prtBertCounter Integer32, prtTestInitiator INTEGER, prtTestTimeout Integer32 } prtTestIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object is an index of the specific port or interface. For a port, the index will be as agreed between agent and application. For an interface, ifIndex may be used." ::= { prtTestEntry 1 } prtTestCmdAndStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this object to a value as detailed further on (except 0) will initiate a test on the specific port. The test/s requested will be set according to the respective bit. The value of this object will be a sum of (2**n), where n is the Bit: TEST BIT VALUE ----------- --- ------ reserved 0 1 PayloadLoop=RLB 1 (=Remote Loopback) 2 LineLoop=DIG 2 (=Digital) 4 OtherLoop 3 8 InwardLoop=LLB 4 (=Local Loopback) 16 BERT 5 32 LC 6 64 ToneInjection 7 128 Inband 8 256 e.g : If the requested value is 20 -> 010100 -> Bits 2 & 4 are set -> the requested tests are : LineLoopback=DIG InwardLoopback=LLB Not all tests combinations are valid. For valid test combination, see each product's specification. For LRS52, only single test is allowed simultaneously The terminology and order of the first tests (except BERT) is according to the one used for Test Status of DS1 and DS3 standards. The notations : RLB, LLB, DIG are the most used in RAD's products, but they can be different. For exact definition see product's spec. Setting this object to stop (value=0 ; all bits are 0), will stop all the user requested tests running on the selected port. When no test is running on the port, the Get value (test status) will be 0. PayloadLoop=RLB The received signal at this interface is looped through the device. Typically the received signal is looped back for retransmission after it has passed through the device's framing function. LineLoop=DIG The received signal at this interface does not go through the device (minimum penetration) but is looped back out. OtherLoop Loopbacks that are not defined here. InwardLoop=LLB The sent signal at this interface is looped back through the device. LC This loop is applicable only for HSSI interface, towards the router . ToneInjection This loop is applicable for analog voice (like FXS)." ::= { prtTestEntry 2 } prtBertCounter OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the number of BERT errors encountered during the BERT operation. It is valid only when BERT (Bit Error Rate Test) is active on the specific port. The Counter starts from zero (0) anytime BERT is initiated." ::= { prtTestEntry 3} prtTestInitiator OBJECT-TYPE SYNTAX INTEGER { unknown (1), user (2), remoteUnit(3), dteRouter (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates who initiated this port's test/s." ::= { prtTestEntry 4 } prtTestTimeout OBJECT-TYPE SYNTAX Integer32 (0..4095) MAX-ACCESS read-write STATUS current DESCRIPTION "This object is applicable only when a single test is running. It indicates the test activation timeout in minutes. When the timeout expires, the test is stopped. Value of 0 indicates test may run Forever " ::= { prtTestEntry 5 } --Port General Parameters prtParam OBJECT IDENTIFIER ::= { systemPort 5 } prtParamTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtParamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table includes general port parameters. The meaning is different for every product that supports it due to a general parameter - prtControlCnfg. For ACE2002: This table is used as a mechanism to create the next interface index. The algorithm description: The NMS will send the agent the following get command: get(nextIfIndex.index), where index=interface on which the new index is dependent on. Upon this command the agent will generate and return the new index to the NMS." ::= {prtParam 1} prtParamEntry OBJECT-TYPE SYNTAX PrtParamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtParamIdx} ::= { prtParamTable 1 } PrtParamEntry ::= SEQUENCE { prtParamIdx Integer32, prtControlCnfg Integer32, prtParamClkSrc INTEGER, prtParamPhantom INTEGER, prtParamResetStatsCmd INTEGER, prtParamLastResetStatsTime TimeStamp } prtParamIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object is an index of the specific port or interface. For a port, the index will be as agreed between agent and application. For an interface, ifIndex may be used. For ACE2002: This parameter is the physical layer ifIndex of the slot on which the NMS requires the next interface index." ::= { prtParamEntry 1 } prtControlCnfg OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object may be used for port RW general parameter/s. For detailed meaning, see product's spec. Supported by: PRBi-E3/T3. For ACE2002: This parameter will include the value of the new index generated by agent. For Optimux-T3: This parameter will be used for Release Remote LLB Command: on=2= Set value only. Command to release LLB of Remote Unit. Agent will return automatically to 'off' value after performing the command. off=3=Get value only. For LA140 This parameter will be used as EchoCanceler per timeslot off = 2 Echo Canceler is disabled on = 3 Echo Canceler is enabled " ::= { prtParamEntry 2 } prtParamClkSrc OBJECT-TYPE SYNTAX INTEGER { loopTiming (1), localTiming (2), throughTiming (3), adaptive (4), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "The source of Transmit Clock. 'loopTiming' or 'loopback' indicates that the recovered receive clock is used as the transmit clock. 'localTiming' or 'internal' indicates that a local clock source is used or when an external clock is attached to the box containing the interface. 'throughTiming' or 'external' indicates that recovered receive clock from another card or interface is used as the transmit clock. 'adaptive' indicates that the clock is recovered according to the received data flow rate. " ::= { prtParamEntry 3 } prtParamPhantom OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Power feeding to another device." ::= { prtParamEntry 4 } prtParamResetStatsCmd OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Reset statistics of the selected port." ::= { prtParamEntry 5 } prtParamLastResetStatsTime OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The value of MIB II's sysUpTime object at the last time that prtParamResetStatsCmd was Set to on(3) for this port. If prtParamResetStatsCmd was never Set to on(3) since last re-initialization of the agent, then this object contains a zero value. This object enables calculating the running time of Statistics counters for this port, by: [sysUpTime-prtParamLastResetStatsTime]." ::= { prtParamEntry 6 } prtIP OBJECT IDENTIFIER ::= { systemPort 6 } prtIpParamTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtIpParamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table - Parameters for IP Ports." ::= {prtIP 1} prtIpParamEntry OBJECT-TYPE SYNTAX PrtIpParamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { prtIpParamConfigIdx, prtIpParamSlotIdx, prtIpParamIdx } ::= { prtIpParamTable 1 } PrtIpParamEntry ::= SEQUENCE { prtIpParamConfigIdx Integer32, prtIpParamSlotIdx Integer32, prtIpParamIdx Integer32, prtIpParamHostIP IpAddress, prtIpParamHostMask IpAddress, prtIpParamDefaultGateway IpAddress, prtIpParamMediaMode INTEGER, prtIpParamMediaRate INTEGER, prtIpParamMngVlanSupport INTEGER, prtIpParamMngVlanId Integer32, prtIpParamMngVlanPriority Integer32, prtIpParamRingMode INTEGER } prtIpParamConfigIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Configuration number (1..255) referred. Value of 255 specifies the TmpCnfg (Scratch). For products having Agent and Edit configurations, Write operation for the table entries is allowed only to Config=255." ::= { prtIpParamEntry 1 } prtIpParamSlotIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a unique number of the slot position in which the module is inserted. notApplicable = 255 (for products that don't have slots). For KM: kmxMlA (103), kmxMlB (104)." ::= { prtIpParamEntry 2 } prtIpParamIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a unique Port Index." ::= { prtIpParamEntry 3 } prtIpParamHostIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The host interface IP address." ::= { prtIpParamEntry 4 } prtIpParamHostMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The host interface subnet mask." ::= { prtIpParamEntry 5 } prtIpParamDefaultGateway OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Default Gateway's IP Address." ::= { prtIpParamEntry 6 } prtIpParamMediaMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), halfDuplex (2), fullDuplex (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the real Media Mode." ::= { prtIpParamEntry 7 } prtIpParamMediaRate OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), r10Mbps (2), r100Mbps (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the real Media Rate (Mbps)." ::= { prtIpParamEntry 8 } prtIpParamMngVlanSupport OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Management VLAN support (Tagging). no - No support of VLAN Tagging. yes - 4 VLAN bytes will be added to the frame." ::= { prtIpParamEntry 9 } prtIpParamMngVlanId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Management VLAN ID." ::= { prtIpParamEntry 10 } prtIpParamMngVlanPriority OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Management VLAN Frame priority." ::= { prtIpParamEntry 11 } prtIpParamRingMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates If Ring Mode is enabled or not." ::= { prtIpParamEntry 12 } systemResetAllStatsCmd OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Reset statistics of all ports and connections of the device." ::= { agnt 16 } systemClearTablesCmd OBJECT-TYPE SYNTAX INTEGER { off(2), tempCnfgTables (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "tempCnfgTables - Set *RowStatus = destroy for all entries of some tables having *RowStatus object, for temporary configuration only! (255). For the relevant tables, see product's specification. This object should be used by WAN product applications before performing the Update operation, in order to clear old entries of these tables. off - agent will automatically change to this value, after performing the command. " ::= { agnt 17 } systemParameter OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter can be used for different purposes: - TELNET session time-out in seconds. - Ace20: when trying to create row in a table that already has row with the same values, if set of values has to be unique in table, this attribute is set to the index of the existing row. - Optimux-T3: when CH interfaces are RJ-45, user can select via this object, the interface type for each Group of channels: T1 or E1: The selection will be a sum of the following Bits. '0' = T1 '1' = E1 Bit Group Value for each Bit having '1' 1 1 (CH-1..CH-8) 1 2 2 (CH-9..CH-12) 2 3 3 (CH-13..CH-20) 4 4 4 (CH-21..CH-28) 8 Examples: 15 = all Groups are selected to be E1 6 = Group 2 and Group 3 are selected to be E1 (Group 1 and Group 4 are T1). - FCD-A, FCD-M: user can select via this object the configuration used for Get values of MSDSL parameters that don't have configuration index. 1 =active configuration 255=temporary configuration. Set of this object should be done before Getting the MSDSL RW parameters. - Ace2002: This parameter indicates the number of intervals that were successfully uploaded upon statistics collection session. - FCD-IP, WR, FCD-IPD, LA-240: This parameter indicates whether Telnet Access is enabled/disabled: Values: 2 - Telnet Access is Disabled. 3 - Telnet Access is Enabled. - Vmux-110: This parameter value equals maximum number of bundles." ::= { agnt 18 } agnGlobalAlarmMask OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "The value of this attribute determines the alarm traps the agent should mask and not send to the managers. Each bit from a certain octet represents a certain alarm." ::= { agnt 19 } alarmSeverity OBJECT-TYPE SYNTAX INTEGER { event (3), minor (4), major (5), warning (6), critical (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the severity of the alarms." ::= { agnt 20 } alarmState OBJECT-TYPE SYNTAX INTEGER { off (2), -- End, on (3) -- Start. } MAX-ACCESS read-only STATUS current DESCRIPTION "." ::= { agnt 21 } agnTestStatus OBJECT-TYPE SYNTAX INTEGER { off (2), on (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current test status (for all levels: system, card, port). This attribute will be set to: on(3): when there is at least one test in progress on the system/card/port off(2): when there is NO test in progress on the system/card/port" ::= {agnt 22 } systemSaveAndResetAllStatsCmd OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "on - a command to Save data of Current Period in Last Period data-set and start a new counting period for Current Period. off - agent will automatically change to this value, after performing the command." ::= { agnt 23 } systemDefaultGateway OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Default Gateway's IP Address." ::= { agnt 24 } -- PS Table systemPsTable OBJECT-TYPE SYNTAX SEQUENCE OF SystemPsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table describes the PS types of a device. Usage of this table is specified in the device's NMS SRS" ::= { agnt 25 } systemPsEntry OBJECT-TYPE SYNTAX SystemPsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {systemPsIndex1, systemPsIndex2} ::= { systemPsTable 1 } SystemPsEntry ::= SEQUENCE { systemPsIndex1 Integer32, systemPsIndex2 Integer32, systemPsType INTEGER, systemPsStatus INTEGER, systemPsHotSwap INTEGER } systemPsIndex1 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "First Index. In HUBs: 1 = PS-A slot 2 = PS-B slot. In SA units: 1 = PS1 2 = PS2 Default = 1" ::= { systemPsEntry 1 } systemPsIndex2 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Second Index. In HUBs: 1 always. In SA units: 1 = Local 2 = Remote Default = 1." ::= { systemPsEntry 2 } systemPsType OBJECT-TYPE SYNTAX INTEGER { none (1), ac (2), dc (3), acDc (4), acPF (5), dcPF (6) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of PS, for a stand-alone product. acDc - AC with rj45 DC. acPF - Power Feeding (phantom) box that is feeding another box by external AC. dcPF - Power Feeding (phantom) box that is feeding another box by external DC." ::= { systemPsEntry 3 } systemPsStatus OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), failed (2), ok (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Status of the PS unit." ::= { systemPsEntry 4 } systemPsHotSwap OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), fixed (2), hotSwap (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Is PS unit hot swap or fixed." ::= { systemPsEntry 5 } agnFans OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This entry specifies the FANs existence and status. Each fan will be represented by 2 bits, where the first bit (right) will specify the existence: (0= Not exist, 1=exist), and the left bit will specify it's status (0= OK, 1=FAIL), so for each fan: 00 - FAN does not exist 01 - FAN exists and OK 11 - FAN exists and is Failed bits 0-1 are for first fan bits 2-3 are for 2nd fan (if exists)." ::= { agnt 26 } agnSendTrapParameter OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies if the agent will attach a specific parameter to a trap. For ACE2002 the agent will attach or not the openViewSeverity parameter according to the value of this parameter: 1 - will attach openViewSeverity. 0 - will not attach openViewSeverity." ::= { agnt 27 } --agnt 28-29 are reserved xcIndexNext OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains an appropriate value to be used for xcIndex when creating entries in the xcTable. The value 0 indicates that no unassigned entries are available. To obtain the xcIndex value for a new entry, the manager issues a management protocol retrieval operation to obtain the current value of this object. After each retrieval, the agent should modify the value to the next unassigned index. After a manager retrieves a value the agent will determine through its local policy when this index value will be made available for reuse." ::= { agnt 30 } --XC Table xcTable OBJECT-TYPE SYNTAX SEQUENCE OF XcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Configuration of system cross-connect entries. The table follows the behavior described in RFC 2515, RFC 1604 regarding the creation deletion and modification of an entry within the table." ::= { agnt 31 } xcEntry OBJECT-TYPE SYNTAX XcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { xcIndex, xcIfIndex1, xcVpi, xcVci, xcIfIndex2 } ::= { xcTable 1} XcEntry ::= SEQUENCE { xcIndex Integer32, xcIfIndex1 Integer32, xcVpi Integer32, xcVci Integer32, xcIfIndex2 Integer32, xcRowStatus RowStatus, xcDescr DisplayString, xcAdminStatus INTEGER, xcOperStatus INTEGER } xcIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Cross Connect Identifier." ::= { xcEntry 1 } xcIfIndex1 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The interface Index from the ifTable, which identify one side of the connection." ::= { xcEntry 2 } xcVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The VPI of the ATM End-Point." ::= { xcEntry 3 } xcVci OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The VCI of the ATM End-Point." ::= { xcEntry 4 } xcIfIndex2 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The interface Index from the ifTable, which identifies the other side of the connection." ::= { xcEntry 5 } xcRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This parameter allows NMS to create/delete entries of this table." ::= { xcEntry 6 } xcDescr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "A textual string containing information about the xc entry." ::= { xcEntry 7 } xcAdminStatus OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "The desired administrative status of this bi-directional cross-connect." ::= { xcEntry 8 } xcOperStatus OBJECT-TYPE SYNTAX INTEGER { up(1), down(2), unknown(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The operational status of this bi-directional cross-connect." ::= { xcEntry 9 } systemModule OBJECT IDENTIFIER ::= { agnt 32 } modlParam OBJECT IDENTIFIER ::= { systemModule 1 } modlParamTable OBJECT-TYPE SYNTAX SEQUENCE OF ModlParamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table include parameters for system modules." ::= { modlParam 1 } modlParamEntry OBJECT-TYPE SYNTAX ModlParamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { modlParamIndex } ::= { modlParamTable 1} ModlParamEntry ::= SEQUENCE { modlParamIndex Integer32, modlParamReset INTEGER, modlParamSwdlStatus INTEGER, modlParamLeds OCTET STRING } modlParamIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The module index. The index can be the slot number or any other module index as described in the specifications of the device. For Vmux-2100 device, the index will have values of: 1..4 for slots 1..4." ::= { modlParamEntry 1 } modlParamReset OBJECT-TYPE SYNTAX INTEGER { off (2), on (3), factory (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Reset action to be performed on the module. Set the parameter will be done always to on(3) or factory (4). After performing the Reset operation, Agent will automatically set the parameter to off(2)." ::= { modlParamEntry 2 } modlParamSwdlStatus OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), off (2), inProcess (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates whatever the swdl is in process or not." ::= {modlParamEntry 3} modlParamLeds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This entry specifies the LEDs status of the module. Each led is represented by 4 bits where the first 2 bits (left) specify the status : (00=NA, 01=OFF, 10=ON, 11=BLINK), and the next two bits (right) specify the color : (00=GREEN, 01=RED, 10=YELLOW, 11=GRAY). The order of the LEDS is from top to bottom, left to right: For each row starting from the top, the LEDS are returned from left to right." ::= {modlParamEntry 4} agnNearFarConnection OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disconnected (2), connected (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter describes the connection between near-end and far-end agents." ::= { agnt 33 } agnAccess OBJECT IDENTIFIER ::= {agnt 34} agnTelnetAccess OBJECT-TYPE SYNTAX INTEGER { disable (2), enable (3), managersOnly (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable accessing the device via Telnet. disable - no one will be allowed to access the device via Telnet. enable - all users are allowed Telnet Access. managersOnly - Only manager stations listed in the manager's list are allowed." ::= { agnAccess 1 } --TRAPS --NOTIFICATIONS systemsEvents OBJECT-IDENTITY STATUS current DESCRIPTION "The events for RAD products." ::= { systems 0 } tftpStatusChangeTrap NOTIFICATION-TYPE OBJECTS { tftpStatus } STATUS current DESCRIPTION "This trap is sent whenever the status of tftp changed." ::= { systemsEvents 1 } agnStatusChangeTrap NOTIFICATION-TYPE OBJECTS {agnIndication } STATUS current DESCRIPTION "This trap is sent whenever the state of the entity the agent is responsible for changed. TDM devices will send agnTestStatus variable to indicate the current test status." ::= { systemsEvents 2 } prtStatusChangeTrap NOTIFICATION-TYPE STATUS current DESCRIPTION "This trap is sent whenever the state of a port changed. Attached, will be parameter/s that indicate the new port status. The attached variables will be specified in the specifications of the products supporting this trap." ::= { systemsEvents 3 } swdlStatusResult NOTIFICATION-TYPE OBJECTS {swdlStatusFileName} STATUS current DESCRIPTION "This notification is sent when Software Down Load is finished. The attached object indicates the File Name." ::= { systemsEvents 4 } intSwdlSlotFileMismatch NOTIFICATION-TYPE OBJECTS {intSwdlFileName} STATUS current DESCRIPTION "This notification is sent when the card in the chosen slot doesn't match the chosen file. The attached object indicates the File Name." ::= { systemsEvents 5 } agnCounterChange NOTIFICATION-TYPE STATUS current DESCRIPTION "This notification is sent when the value of a specific Counter is changed. Agent can send as attached object the updated Counter. For details about this Counter and attached object, see spec of the relevant application." ::= { systemsEvents 6 } prtClkSrcChangeTrap NOTIFICATION-TYPE STATUS current DESCRIPTION "This trap is sent upon any port clock change." ::= { systemsEvents 7 } moduleFailTrap NOTIFICATION-TYPE STATUS current DESCRIPTION "This trap is sent upon a module failure." ::= { systemsEvents 8 } moduleInitFailTrap NOTIFICATION-TYPE STATUS current DESCRIPTION "This trap is sent upon a module initialization failure." ::= { systemsEvents 9 } clkSrcChangeTrap NOTIFICATION-TYPE STATUS current DESCRIPTION "This trap is sent upon any change in Clock Source." ::= { systemsEvents 10 } agnUploadDataTrap NOTIFICATION-TYPE STATUS current DESCRIPTION "This trap is sent upon an upload data session termination. For more details see product specification." ::= { systemsEvents 11 } enrollmentTrap NOTIFICATION-TYPE STATUS current DESCRIPTION "This trap is a periodic trap, which is sent to manager until Agent gets any response (Get or Set) from this manager." ::= { systemsEvents 12 } agnPowerFailureTrap NOTIFICATION-TYPE STATUS current DESCRIPTION "This trap is sent upon power failure. It is applicable for devices having one PS unit, which sense in advance the failure, and still have time to send this trap before it goes off." ::= { systemsEvents 13 } -- -- file :v:\doc\rdv\mib\Before~1\trgen.txt -- --Version: 4.0 --Date: 16.10.94 --By: Orly Nicklass --File: TRGEN.TXT --Last update: 05.12.95 trGen OBJECT IDENTIFIER ::= {radTokenRing 1} -- agnRR OBJECT IDENTIFIER ::= {trGen 1} --agent RAD ring general information ringTR OBJECT IDENTIFIER ::= { trGen 2 } --ring general information segTR OBJECT IDENTIFIER ::= { trGen 3} -- segment general information moduleTR OBJECT IDENTIFIER ::= {trGen 4} -- Module general information prtTR OBJECT IDENTIFIER ::= {trGen 5 } --port general information -- -- RADRing agent specific information -- agnRRcoprocHwVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ASCII string for description and display of the CML\IB hardware version. If the entry is not applicable, it will display the string -NOT APPLICABLE-" ::= { agnRR 1 } agnRRrecMode OBJECT-TYPE SYNTAX INTEGER { unknown(1), slow(2), fast(3), notSupported(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The manager station can assist the agent in the autorecovery process by setting this value to SLOW(1). This value indicates the presence of old modules within the radring hub. Autorecovery process will be faster for new modules. However it might fail if set to FAST(2) and old modules are inserted." ::= { agnRR 2 } agnRRmaskIBMalrt OBJECT-TYPE SYNTAX INTEGER { unknown(1), disabled(2), enabled(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "When this object is set to the value of Enabled(3), Agent-traps that are not masked will also be sent to the IBM LAN manager using IBM's Alert Transport Service Protocol. This object is applicable only for TR agents." ::= { agnRR 3} agnRRResetConfig OBJECT-TYPE SYNTAX INTEGER { off(2), on(3), notSupported(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting the value to ON(3)is interpreted as a reset command for the agent NV Ram. When reset process is ended, a trap will be issued. If the entry is not applicable, The value notSupported will be read." ::= { agnRR 4 } agnRRSwReset OBJECT-TYPE SYNTAX INTEGER { off(2), on(3) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Setting the value to ON(3)is interpreted as a software reset command for the agent. When reset process is ended, a trap will be issued. " ::= { agnRR 5 } agnRRRingReportMngr OBJECT-TYPE SYNTAX INTEGER { off(2), on(3) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Setting the value to ON(3) is interpreted as assigning the duty of Ring Report Manager on the agent " ::= { agnRR 6 } agnRRSubSysCommState OBJECT-TYPE SYNTAX INTEGER { failed(2), ok(3), notSupported(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the status of communication between the two agent's processors. The communication is failed when the CML/NM card is removed" ::= { agnRR 7 } -- -- Ring information for the ring the agent is connected to. It is traffic information and -- isolated error information. -- ringResetStatistics OBJECT-TYPE SYNTAX INTEGER { unknown(1), off(2), on(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting the value of this attribute to ON(3) resets all the inband statistics and error counters." ::= { ringTR 1 } ringCurrentTraffic OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Momentary traffic for the last time interval. The traffic is expressed in percents of the maximum Tokenring traffic ." ::= { ringTR 2 } ringPeakTraffic OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Maximal traffic value since last reset of Agent or statistics. Expressed in percents of the maximum Tokenring traffic." ::= { ringTR 3 } ringTrafficTreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Traffic threshold value. When reached, a trap will be sent to the management console. Expressed in percents of the maximum Tokenring traffic" ::= { ringTR 4 } ringLineErrCnt OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is incremented when a frame or token is copied or repeated by any of the stations on the ring, the E bit is zero in the frame or token and one of the following conditions exists: 1) there is a non-data bit (J or K bit) between the SD and the ED of the frame or token, or 2) there is an FCS error in the frame." ::= { ringTR 5 } ringLineErr OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is incremented when a frame or token is copied or repeated by any of the stations on the ring, the E bit is zero in the frame or token and one of the following conditions exists: 1) there is a non-data bit (J or K bit) between the SD and the ED of the frame or token, or 2) there is an FCS error in the frame." ::= { ringTR 6 } ringBurstErrCnt OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is incremented when any of the stations on the ring detects the absence of transitions for five half-bit timers (burst-five error)." ::= { ringTR 7 } ringBurstErr OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is incremented when any of the stations on the ring detects the absence of transitions for five half-bit timers (burst-five error)." ::= { ringTR 8 } ringACFCErrCnt OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is incremented when any of the stations on the ring receives an AMP or SMP frame in which A is equal to C is equal to 0, and then receives another SMP frame with A is equal to C is equal to 0 without first receiving an AMP frame. It denotes a station that cannot set the AC bits properly." ::= { ringTR 9 } ringACFCErr OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is incremented when any of the stations on the ring receives an AMP or SMP frame in which A is equal to C is equal to 0, and then receives another SMP frame with A is equal to C is equal to 0 without first receiving an AMP frame. It denotes a station that cannot set the AC bits properly." ::= { ringTR 10 } ringTotErrCnt OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total of the above described errors" ::= { ringTR 11 } ringTotErr OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total of the above described errors" ::= { ringTR 12 } ringTotErrThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The threshold value of the total of the above described errors.When the threshold is reached a trap indicating the status of the ring (SOFT ERROR)will be sent to the management station" ::= { ringTR 13} ringStatus OBJECT-TYPE SYNTAX INTEGER { unknown(1), normal(2), softError(3), beacon(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Describes the status of the LAN segment the agent is attached to: Normal(2) - The LAN segment is operating normally SoftError(3) - The Token ring LAN segment (ring) is experiencing intermittent failures that temporarily harm the ring's performance and cause data to be transmitted more than ones. Beaconing(4) - The ring is not operative; no data is transmitted." ::= { ringTR 14 } ringConfigMsg OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Full configuration message coded in internal RAD application format. This entry describes ring information. " ::= { ringTR 15 } ringCurrentTrafficCnt OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Momentary traffic for the last time interval. The traffic is expressed as bits per second." ::= { ringTR 16 } -- -- Segments -- segTRTable OBJECT-TYPE SYNTAX SEQUENCE OF SegTREntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Segments." ::= { segTR 1} segTREntry OBJECT-TYPE SYNTAX SegTREntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table segTRTable." INDEX { segTRID} ::= { segTRTable 1} SegTREntry ::= SEQUENCE { segTRID Integer32, segTRLastSlot Integer32, segTRFirstSlot Integer32, segTRStatus INTEGER } segTRID OBJECT-TYPE SYNTAX Integer32 (1..20) MAX-ACCESS read-only STATUS current DESCRIPTION "Segment unique identification number (internal). It is the extreme left slot, marking the beginning of the segment." ::= { segTREntry 1 } segTRLastSlot OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Location of the right most slot marking the end of the segment. In the RADring hub it is slot number 20 or the slot where end of segment module is inserted or the slot before a beginning of a new segment. ( End of segment module could be one with termination on or TIO, TFR, TCR etc.)" ::= { segTREntry 2 } segTRFirstSlot OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Location of the left most slot marking the beginning of the segment. In the RADring hub it is slot number 1 or the slot number following the end of segment module, or where a repeater or TIO is inserted." ::= { segTREntry 3 } segTRStatus OBJECT-TYPE SYNTAX INTEGER { unknown(1), beaconing(2), normal(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Describes the status of the segment : Normal(3) - The segment is operating normally Beaconing(2) - The ring is not operative; no data is transmitted. Segment without inband module within its limit will display Unknown(1). This entry is specially usefull when the hub is configured with multiple segments and each segment is part of another net" ::= { segTREntry 4 } -- -- Modules parameters structure -- contains general information about the modules -- mdlTRTable OBJECT-TYPE SYNTAX SEQUENCE OF MdlTREntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Modules parameters structure contains general information about the modules." ::= { moduleTR 1 } mdlTREntry OBJECT-TYPE SYNTAX MdlTREntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table mdlTRTable." INDEX { mdlTRID } ::= { mdlTRTable 1 } MdlTREntry ::= SEQUENCE { mdlTRID Integer32, mdlTRSegID Integer32, mdlTRType INTEGER, mdlTRHwVer DisplayString, mdlTRSwVer DisplayString, mdlTRTotalNoOfPrt Integer32, mdlTRSpecific OBJECT IDENTIFIER } mdlTRID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The slot number where the module is inserted. Can not be greater than chNoSlot" ::= { mdlTREntry 1 } mdlTRSegID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The segment number where the module belongs to. One of the segTRID values." ::= {mdlTREntry 2 } mdlTRType OBJECT-TYPE SYNTAX INTEGER { unknown(1), empty(2), tl4s(3), tl4su(4), tl4sd(5), tl4cx(6), tl4u(7), tl2edu(8), tl2eds(9), tl2edsu(10), tl2f(11), tja(12), tio(13), tfr(14), tfc1(15), tfc2(16), tcr(17), tl4au(18), tl4as(19), tl4asd(20), tl4asu(21), tre1d(22), tre(23), tre8d(24), stc1(25), stc2(26), ftc(27), cmlib(28), tl2fsat(29), nonTR(30), tau(31), -- for all TAUs type rmu(32) -- for all RMUs type } MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Indicates the type of the module connected at the specified slot number." ::= { mdlTREntry 3 } mdlTRHwVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ASCII string for description and display of the module's hardware version, as it is known by the module's software. A manager can record his own hardware upgrade." ::= { mdlTREntry 4 } mdlTRSwVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "ASCII string for description and display of the module's software version. A value of NOT APPLICABLE will be recorded for module having no independent processor." ::= { mdlTREntry 5 } mdlTRTotalNoOfPrt OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This entry describes the number of possible ports/lobes/links connection in the module (not all ports hardware should be active) ." ::= { mdlTREntry 6 } mdlTRSpecific OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION " Object identifier of entity containing additional information regarding this instance. This entry is type specific." ::= { mdlTREntry 7 } -- -- TReral port table for any media type -- prtTRTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtTREntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "TReral port table for any media type." ::= { prtTR 1 } prtTREntry OBJECT-TYPE SYNTAX PrtTREntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table prtTRTable." INDEX { prtTRModuleID,prtTRID } ::= { prtTRTable 1 } PrtTREntry ::= SEQUENCE { prtTRModuleID Integer32, prtTRID Integer32, prtTRFunctionality INTEGER, prtTRConnectorType INTEGER, prtTRAdminCmd INTEGER, prtTRActiveState INTEGER, prtTRTrapMaskEnable INTEGER, prtTRstatus INTEGER, prtTRCableProtectEnable INTEGER, prtTRCableState INTEGER, prtTRMACAddress MacAddress, prtTRSpecific OBJECT IDENTIFIER } prtTRModuleID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier of the module(slot no.)this port is attached to." ::= { prtTREntry 1 } prtTRID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier of the port within its module." ::= { prtTREntry 2 } prtTRFunctionality OBJECT-TYPE SYNTAX INTEGER { unknown(1), ringin(2) , ringout(3) , satellite(4), lobe(5), link(6), tja(7), none(8), -- N.C. repeater smart-port(9) -- for RR-SAT if prtRRMode is set to smart-port } MAX-ACCESS read-only STATUS current DESCRIPTION "Describes the functionality of the port in a Token ring topology or other implementations." ::= { prtTREntry 3 } prtTRConnectorType OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), idc(2), rj45(3), srj45(4), db9(5), bnc(6), foSt(7), db25(8) -- foSma(9), -- foFc(10) } MAX-ACCESS read-only STATUS current DESCRIPTION "Type of hardware connector in the port." ::= { prtTREntry 4 } prtTRAdminCmd OBJECT-TYPE SYNTAX INTEGER { unknown(1), disable(2), enable(3), short(4), normal(5) } MAX-ACCESS read-write STATUS current DESCRIPTION "By setting this attribute to DISABLE(2) or SHORT(4) the management station can force this lobe/port/link-connection to be removed and block any access to the network via this lobe/port/link. It is not mandatory that a certain lobe/port/link will support all the enumerated states. The state of the lobe/port/link is type specific and indicated within the specific group" ::= { prtTREntry 5 } prtTRActiveState OBJECT-TYPE SYNTAX INTEGER { unknown(1), off(2), on(3), standby(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute describes the electrical or optical activity state of a lobe or the state of a port. Certain values may not be applicable in some cases" ::= { prtTREntry 6 } prtTRTrapMaskEnable OBJECT-TYPE SYNTAX INTEGER { off(2), on(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "When this attribute is set to OFF by the management console the agent starts sending the unmasked traps related to this port. Otherwise no traps from this port are sent." ::= { prtTREntry 7 } prtTRstatus OBJECT-TYPE SYNTAX INTEGER { unknown(1), disabledManuall(2), disabledAutorec(3), disabledSecurity(4), disableAuto(5), disableFlip(6), inserted(7), bypass(8), forcedloop(9), trunkfail(10), normal(11) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the status of this lobe/port connection: DISABLED - (2) to (6) indicates the reason for the disabled state. INSERTED - (7)indicates that the lobe hardware inserts this lobe into the ring , thus it becomes part of the ring. BYPASS - (8)indicates that the ring bypasses this lobe and the lobe hardware provides loopback connection towards the station for media test purposes. FORCEDLOOP - (9) indicates the port is in a loopback state and the main ring is connected to the backup path. TRUNKFAIL - (10) indicates that the ring connection is broken for a repeater, converter or a cable protector. NORMAL - (11) indicates the port is in normal condition. It is not mandatory that a certain lobe/port will support all the enumerated states." ::= { prtTREntry 8 } prtTRCableProtectEnable OBJECT-TYPE SYNTAX INTEGER { unknown(1), off(2), on(3), inhibit(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this attribute determines activation of the cable-fault protection mechanism of TCR and the optical link mechanism of TFR and TFC ." ::= { prtTREntry 9 } prtTRCableState OBJECT-TYPE SYNTAX INTEGER { unknown(1), failed(2), normal(3), remoteFailed(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this attribute determines the cable status of TCR and the optical link mechanism of TFR and TFC ." ::= { prtTREntry 10} prtTRMACAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object is the specific MAC address of this interface which uniquely identifies this Interface on a ring." ::= { prtTREntry 11 } prtTRSpecific OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION " Object identifier of entity containing additional information regarding this instance. This entry is type specific." ::= { prtTREntry 12} prtTRMacAddressTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtTRMacAddressEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "." ::= { prtTR 2 } prtTRMacAddressEntry OBJECT-TYPE SYNTAX PrtTRMacAddressEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table prtTRMacAddressTable." INDEX { prtTRMacAddressModuleID,prtTRMacAddressPortID, prtTRMacAddressID} ::= { prtTRMacAddressTable 1 } PrtTRMacAddressEntry ::= SEQUENCE { prtTRMacAddressModuleID Integer32, prtTRMacAddressPortID Integer32, prtTRMacAddressID Integer32, prtTRMACAddressValue MacAddress } prtTRMacAddressModuleID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier of the module(slot no.)this port is attached to." ::= { prtTRMacAddressEntry 1 } prtTRMacAddressPortID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier of the port within its module." ::= { prtTRMacAddressEntry 2 } prtTRMacAddressID OBJECT-TYPE SYNTAX Integer32 (1..250) MAX-ACCESS read-only STATUS current DESCRIPTION "A identifier of the MAC address in the list according to the ring order" ::= { prtTRMacAddressEntry 3 } prtTRMACAddressValue OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION " MAC address from the list of addresses connected to this port" ::= { prtTRMacAddressEntry 4 } -- -- file :v:\doc\rdv\mib\Before~1\radring.txt -- --Version: 4.00 --Original : 30.11.93 --Last revision: 05.12.95 --File: radring.txt -- radRing OBJECT IDENTIFIER ::= {radTokenRing 2} -- chasRR OBJECT IDENTIFIER ::= {radRing 1} -- Chassis information segRR OBJECT IDENTIFIER ::= { radRing 2 } -- segment information moduleRR OBJECT IDENTIFIER ::= { radRing 3 } --Module information prtRR OBJECT IDENTIFIER ::= { radRing 4 } -- Port information -- -- Chassis description for any object having to be surrounded by a frame -- chType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " This value indicates which type of enclosure the Rad agent is managing. The default value will be RadRing" ::= { chasRR 1 } chNoSlot OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This value indicates the number of manageable slots in the chassis. Not all slots must be occupied." ::= { chasRR 2 } chPSPrimary OBJECT-TYPE SYNTAX INTEGER { unknown(1), off(2), fault(3), active(4), recovered(5), none(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the status of the main (primary) power supply unit " ::= { chasRR 3 } chPSSecondary OBJECT-TYPE SYNTAX INTEGER { unknown(1), off( 2), fault(3), active(4), recovered(5), none( 6) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the status of the secondary power supply unit" ::= { chasRR 4 } chTemperature OBJECT-TYPE SYNTAX INTEGER { ok(1), exceed(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates if the internal hub temperature exceeded the permissible maximum " ::= { chasRR 5 } chEtMainClock OBJECT-TYPE SYNTAX INTEGER { unknown(1), ok(2), fault(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the status of Eternet repeater main clock in RadRingII hub" ::= { chasRR 6 } chEtSecClock OBJECT-TYPE SYNTAX INTEGER { unknown(1), ok(2), fault(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the status of Eternet repeater secondary clock in RadRingII hub" ::= { chasRR 7 } -- -- RADRing segments' specific information -- segRRSecurityTable OBJECT-TYPE SYNTAX SEQUENCE OF SegRRSecEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "RADRing segments' specific information" ::= { segRR 1} segRRSecEntry OBJECT-TYPE SYNTAX SegRRSecEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table segRRSecurityTable." INDEX { segRRID, segRRSecID} ::= { segRRSecurityTable 1} SegRRSecEntry ::= SEQUENCE { segRRID Integer32, segRRSecID Integer32, segRRSecEnable INTEGER, segRRSecurityPattern MacAddress, segRRSecurityMask MacAddress } segRRID OBJECT-TYPE SYNTAX Integer32 (1..21) MAX-ACCESS read-only STATUS current DESCRIPTION "Segment unique identification number (internal). It is the extreme left slot, marking the beginning of the segment. TR segment no.: 1 .. 20 Ethernet segment no.: 21." ::= { segRRSecEntry 1 } segRRSecID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Segment's security unique identification number" ::= { segRRSecEntry 2 } segRRSecEnable OBJECT-TYPE SYNTAX INTEGER { off(2), on(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This entry indicates whether the specific segment's security is active or not" ::= { segRRSecEntry 3 } segRRSecurityPattern OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "A six-octet (48 bit) pattern, where the masked bits of segTRSecurityMask need to match the MAC address of each port within the segment. A Value of all-zeros indicates no security." ::= { segRRSecEntry 4 } segRRSecurityMask OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Mask of the allowed MAC address that can be connected through the ports within the segment" ::= { segRRSecEntry 5} -- -- RADRing specific modules' information -- mdlRRTable OBJECT-TYPE SYNTAX SEQUENCE OF MdlRREntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "RADRing specific modules' information" ::= { moduleRR 1 } mdlRREntry OBJECT-TYPE SYNTAX MdlRREntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table mdlRRTable." INDEX { mdlRRid} ::= { mdlRRTable 1} MdlRREntry ::= SEQUENCE { mdlRRid Integer32, mdlRRTLRstatus INTEGER, mdlRRtermination INTEGER, mdlRRReset INTEGER, mdlRRLed OCTET STRING, mdlRRSpeed INTEGER, mdlRRMngAutoDis INTEGER, mdlRRAutodisable INTEGER, mdlRRConfigMsg OCTET STRING, mdlRRMngState INTEGER, mdlRRType INTEGER, mdlRRHwVer DisplayString, mdlRRSwVer DisplayString, mdlRRSpecific OBJECT IDENTIFIER } mdlRRid OBJECT-TYPE SYNTAX Integer32 (1..20) MAX-ACCESS read-only STATUS current DESCRIPTION "Unique number to identify the module. It indicates the slot number the module is inserted in." ::= { mdlRREntry 1} mdlRRTLRstatus OBJECT-TYPE SYNTAX INTEGER { unknown(1), off(2), on(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This entry specifies the status of the setup on the TL-2/Exx modules. When the value is ON, lobe one is the only active lobe. This entry will have the value UNKNOWN for all other modules " ::= { mdlRREntry 2 } mdlRRtermination OBJECT-TYPE SYNTAX INTEGER { unknown(1), off(2), on(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Attribute describing the termination state as set by the switches on the lobe modules" ::= { mdlRREntry 3 } mdlRRReset OBJECT-TYPE SYNTAX INTEGER { unknown(1), off(2), on(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "When this object is set to the value of ON(3), the module performs software reset. Upon completion, a trap will be issued to the management station and the value will be set to OFF. This entry will have the value of UNKNOWN (1) for modules without independent processors. This command should be masked for the agent module" ::= { mdlRREntry 4 } mdlRRLed OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This entry specifies the LEDs status in the module . Each led will be represented by 4 bits where the first 2 bits will specify the status (NA, OFF, ON, BLINK), and the next two bits will specify the color (RED, GREEN, YELLOW)" ::= { mdlRREntry 5} mdlRRSpeed OBJECT-TYPE SYNTAX INTEGER { unknown(1), -- for WAN cards fourMegabit(2), sixteenMegabit(3), tenMegabit(4) -- for Ethernet } MAX-ACCESS read-only STATUS current DESCRIPTION "Attribute describing the bandwidth of the media as set by the module switches." ::= { mdlRREntry 6 } mdlRRMngAutoDis OBJECT-TYPE SYNTAX INTEGER { unknown(1), off(2), on(3) } MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Attribute describing the setup of the MNG switch on the TL- Active cards. Value ON indicates the ability of activating the auto-disable mechanism of the card via management command. Value OFF indicates that the activation of the auto-disable mechanism of the card is according to the switch setting.In this case the mdlRRAutodisable will not be available for write operation. Applicable to Token Ring cards only. Replaced by mdlRRMngState." ::= { mdlRREntry 7} mdlRRAutodisable OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), off(2), on(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute can be set by the manager if the value of mdlRRMngAutoDis is ON. It controls the behavior of the Active cards regarding the Auto-disable mechanism. All ports will be in the same mode. Applicable to Token Ring cards only." ::= { mdlRREntry 8 } mdlRRConfigMsg OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Full configuration message coded in internal RAD application format. This entry describes module' configuration. " ::= { mdlRREntry 9 } mdlRRMngState OBJECT-TYPE SYNTAX INTEGER { unknown(1), disable(2), enable(3) } MAX-ACCESS read-only STATUS current DESCRIPTION " This entry indicates the setting of the module's switches. ENABLE means that the module can accept management commands. " ::= { mdlRREntry 10 } mdlRRType OBJECT-TYPE SYNTAX INTEGER { unknown(1), empty(2), tl4s(3), tl4su(4), tl4sd(5), tl4cx(6), tl4u(7), tl2edu(8), tl2eds(9), tl2edsu(10), tl2f(11), tja(12), tio(13), tfr(14), tfc1(15), tfc2(16), tcr(17), tl4au(18), tl4as(19), tl4asd(20), tl4asu(21), tre1d(22), tre(23), tre8d(24), stc1(25), stc2(26), ftc(27), cmlib(28), tl2fsat(29), -- WAN taV24(30), taV11(31), wangVs(32), ta3x74(33), ta3x(34), -- rr-sat sat-asu(35), sat-asd(36), sat-su(37), sat-sd(38), -- ethernet ep8t(39), ep4taui(40), ep4t2fl(41), ep4tfl(42), ep4fl(43), -- epr epr8t(45), epr4taui(46), epr4t2fl(47), epr4tfl(48), epr4fl(49), -- rr tl2fm(51), ftc2(53), mlbt(54), mlbtf(55), ftbDfo(56), ftbSfo(57), mbe8d(58), mbe1d(59), cmlibE(60) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the type of the module installed in the specified slot number." ::= { mdlRREntry 11} mdlRRHwVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ASCII string for description and display of the module's hardware version, as it is known by the module's software. A manager can record his own hardware upgrade." ::= { mdlRREntry 12 } mdlRRSwVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "ASCII string for description and display of the module's software version. A value of NOT APPLICABLE will be recorded for a module having no independent processor." ::= { mdlRREntry 13 } mdlRRSpecific OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION " Object identifier of entity containing additional information regarding this instance. This entry is module type specific." ::= { mdlRREntry 14 } -- -- Additional parameters that can be monitored for a segment with an inband module. -- Module specific for Token Ring mdlIBTable OBJECT-TYPE SYNTAX SEQUENCE OF MdlIBEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Additional parameters that can be monitored for a segment with an inband module. Module specific for Token Ring" ::= { moduleRR 2 } mdlIBEntry OBJECT-TYPE SYNTAX MdlIBEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table mdlIBTable." INDEX { mdlIBid} ::= { mdlIBTable 1} MdlIBEntry ::= SEQUENCE { mdlIBid Integer32, mdlIBsegID Integer32, mdlIBCorrelationEnable INTEGER, mdlIBAutorecEnable INTEGER, mdlIBAutorecResult INTEGER, mdlIBcommand INTEGER, mdlIBstate INTEGER, mdlIBagnt INTEGER, mdlIBIpAddress IpAddress, mdlIBLocalMacAddr MacAddress, mdlIBbrnInMacAddr MacAddress, mdlIBLocalAddrStatus INTEGER, mdlIBTrapMaskEnable INTEGER } mdlIBid OBJECT-TYPE SYNTAX Integer32 (1..20) MAX-ACCESS read-only STATUS current DESCRIPTION "Unique number to identify the CML\IB module. It indicates the slot number the module is inserted in" ::= { mdlIBEntry 1 } mdlIBsegID OBJECT-TYPE SYNTAX Integer32 (1..20) MAX-ACCESS read-only STATUS current DESCRIPTION "Unique number to identify the segment where the CML\IB module is inserted. It is one of the segTRID values." ::= { mdlIBEntry 2 } mdlIBCorrelationEnable OBJECT-TYPE SYNTAX INTEGER { off(2), on(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "When set to ON(3), the in-band agent should perform correlation each time a station enters/leaves the segment." ::= { mdlIBEntry 3 } mdlIBAutorecEnable OBJECT-TYPE SYNTAX INTEGER { off(2), on(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "When set to ON(3), the in-band agent should perform autorecovery each time a beacon status is detected." ::= { mdlIBEntry 4 } mdlIBAutorecResult OBJECT-TYPE SYNTAX INTEGER { notStarted(1), started(2), segmentOk(3), segmentFixed(4), segmentClosed(5), failed(6), hubProblem(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "When autorecovery is completed the result will be reported (3)..(7). While in autorecovery process, started(2) will be reported. Before autorecovery process, notStarted(1) will be reported." ::= { mdlIBEntry 5 } mdlIBcommand OBJECT-TYPE SYNTAX INTEGER { noOp(1), open(2), reset(3), close(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "When this object is set to the value of open(2), the station should go into the open state. The progress and success of this command is given by the values of the object mdlIBstate. When this object is set to the value of reset(3), then the station should do a reset. On a reset, all MIB counters should retain their values, if possible. Other side effects depend on the hardware chip set. When this object is set to the value of close(4), the station should go into the closed state by removing itself from the ring. Setting this object to a value of no-op(1) has no effect. For read operation, this object has always a value of no-op(1). It is not permitted to apply this command on an agent module." ::= { mdlIBEntry 6 } mdlIBstate OBJECT-TYPE SYNTAX INTEGER { unknown (1), opened(2), closed(3), opening(4), closing(5), badParam(6), lobeFailed(7), signalLoss(8), insertionTimeout(9), ringFailed(10), beaconning(11), duplicateMac(12), requestFailed(13), removeReceived(14), budFailure(15), initFailure(16) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current adapter status, which can be used to diagnose fluctuating problems." ::= { mdlIBEntry 7 } mdlIBagnt OBJECT-TYPE SYNTAX INTEGER { off(2), on (3), standBy (4) } MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates whether the specific inband module serves as: - Active hub agent - (on) - Ring Monitor (for TR module only) - (off) - Standby agent - (standBy)" ::= { mdlIBEntry 8 } mdlIBIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates IP address of the module if the module serves as an agent of itself." ::= { mdlIBEntry 9} mdlIBLocalMacAddr OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The value of this object is the specific MAC address of this interface which uniquely identifies this interface on a ring.It is the address set by the management and upon request it will replace the burn in address. Non-canonical format." ::= { mdlIBEntry 10} mdlIBLocalAddrStatus OBJECT-TYPE SYNTAX INTEGER { unknown(1), off(2), on(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The value of this object specifies whether the specific MAC address of this interface was set by the local management or it is the burn-in address in use." ::= { mdlIBEntry 11 } mdlIBbrnInMacAddr OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object is the specific Burn-in MAC address of this interface which uniquely identifies this interface on a ring. Non-canonical format." ::= { mdlIBEntry 12 } mdlIBTrapMaskEnable OBJECT-TYPE SYNTAX INTEGER { off(2), on(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "When this attribute is set to OFF by the management console, the agent starts sending the unmasked traps related to this module. Otherwise, no traps are sent by this module." ::= { mdlIBEntry 13 } -- Special modules such as bridges/converters that are within the hub -- mdlBRGTable OBJECT-TYPE SYNTAX SEQUENCE OF MdlBRGEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Special modules such as bridges/converters that are within the hub" ::= { moduleRR 3 } mdlBRGEntry OBJECT-TYPE SYNTAX MdlBRGEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table mdlBRGTable." INDEX { mdlBRGid} ::= { mdlBRGTable 1} MdlBRGEntry ::= SEQUENCE { mdlBRGid Integer32, mdlBRGReady INTEGER, mdlBRGStatus DisplayString, mdlBRGLocation INTEGER, mdlBRGIpAddress IpAddress, mdlBRGMacAddr MacAddress, mdlBRGAdapterState INTEGER, mdlBRGBypassSw INTEGER } mdlBRGid OBJECT-TYPE SYNTAX Integer32 (1..20) MAX-ACCESS read-only STATUS current DESCRIPTION "Unique number to identify the module. It indicates the slot number the module is inserted in." ::= { mdlBRGEntry 1} mdlBRGReady OBJECT-TYPE SYNTAX INTEGER { unknown(1), off(2), on(3), blink(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This entry will have the value ON when packets can be transferred in the TRE module. The value UNKNOWN will be used for all other modules where this characteristic is not applicable" ::= { mdlBRGEntry 2} mdlBRGStatus OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This entry specifies the status of operation of the STC or FTC modules. For other modules this value will read NOAP" ::= { mdlBRGEntry 3} mdlBRGLocation OBJECT-TYPE SYNTAX INTEGER { unknown(1), main(2), remote(3), secondary(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This entry indicates the configuration mode: - for the TRE bridge (main/remote) - for MLB-T, MLBT-F (main/secondary) " ::= { mdlBRGEntry 4} mdlBRGIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates IP address of the module if the module serves as an agent of itself. For all other modules the IP value will be 0.0.0.0" ::= { mdlBRGEntry 5} mdlBRGMacAddr OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object is the specific MAC address of this interface which uniquely identifies this interface on a ring." ::= { mdlBRGEntry 6} mdlBRGAdapterState OBJECT-TYPE SYNTAX INTEGER { unknown (1), opened(2), closed(3), opening(4), closing(5), badParam(6), lobeFailed(7), signalLoss(8), insertionTimeout(9), ringFailed(10), beaconning(11), duplicateMac(12), requestFailed(13), removeReceived(14), budFailure(15), initFailure(16) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current adapter status, which can be used to diagnose fluctuating problems. This object is applicable only for TR bridges with adapter. The value 'unknown' will be used for other module types." ::= { mdlBRGEntry 7 } mdlBRGBypassSw OBJECT-TYPE SYNTAX INTEGER { unknown(1), off(2), on(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This entry is applicable only for FTB-D/FO module. It describes the status of the Bypass Switch. The value UNKNOWN will be used for all other modules where this characteristic is not applicable" ::= { mdlBRGEntry 8} -- Special "WAN" modules that are within the RadRing hub -- mdlMMTable OBJECT-TYPE SYNTAX SEQUENCE OF MdlMMEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Special 'WAN' modules that are within the RadRing hub" ::= { moduleRR 4 } mdlMMEntry OBJECT-TYPE SYNTAX MdlMMEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table mdlMMTable." INDEX { mdlMMid} ::= { mdlMMTable 1} MdlMMEntry ::= SEQUENCE { mdlMMid Integer32, mdlMMBertCmd INTEGER } mdlMMid OBJECT-TYPE SYNTAX Integer32 (1..20) MAX-ACCESS read-only STATUS current DESCRIPTION "Unique number to identify the module. It indicates the slot number the module is inserted in." ::= { mdlMMEntry 1} mdlMMBertCmd OBJECT-TYPE SYNTAX INTEGER { unknown(1), off(2), on(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this Object to ON, will start BERT test on all the channels that are currently in Remote Loop. If the value of mdlRRMngState is disabled, this parameter is read-only and reflects the module jumper setting. " ::= { mdlMMEntry 2} -- "Ethernet" modules that are within the hub -- mdlETTable OBJECT-TYPE SYNTAX SEQUENCE OF MdlETEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "'Ethernet' modules that are within the hub" ::= { moduleRR 5 } mdlETEntry OBJECT-TYPE SYNTAX MdlETEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table mdlETTable." INDEX { mdlMMid } ::= { mdlETTable 1} MdlETEntry ::= SEQUENCE { mdlETid Integer32, mdlETSAmode INTEGER } mdlETid OBJECT-TYPE SYNTAX Integer32 (1..20) MAX-ACCESS read-only STATUS current DESCRIPTION "Unique number to identify the module. It indicates the slot number the module is inserted in. It is the same as rptrGroupIndex in the Repeater MIB" ::= { mdlETEntry 1} mdlETSAmode OBJECT-TYPE SYNTAX INTEGER { unknown(1), off(2), on(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this Object to ON, will change the mode of operation of the Ethernet card to a stand alone operation mode. It will disconnect the card from the repeater bus. The rptrGroupOperStatus parameter in the Repeater MIB is changed to other(1). The parameter is read-only when the value of mdlRRMngState is disabled" ::= { mdlETEntry 2 } -- --RADRing specific port information -- prtRRTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtRREntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "RADRing specific port information" ::= { prtRR 1 } prtRREntry OBJECT-TYPE SYNTAX PrtRREntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table prtRRTable." INDEX { prtRRmdlID, prtRRID } ::= { prtRRTable 1 } PrtRREntry ::= SEQUENCE { prtRRmdlID Integer32, prtRRID Integer32, prtRRSecurityState INTEGER, prtRRSecurityEnable INTEGER, prtRRSecurityMask MacAddress, prtRRSecurityPattern MacAddress, prtRRJitterAttenEnable INTEGER, prtRRConfigMsg OCTET STRING, prtRRFlipAutoDisable INTEGER, prtRRSecurityMask2 MacAddress, prtRRSecurityPattern2 MacAddress, prtRRMode INTEGER, prtRRAttachment INTEGER } prtRRmdlID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier of the module,(slot no.),this port is attached to." ::= { prtRREntry 1 } prtRRID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier of the port within its module." ::= { prtRREntry 2 } prtRRSecurityState OBJECT-TYPE SYNTAX INTEGER { notactive(1), active(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This entry indicates whether a security check can be performed on the specific port. This value is directly related to the presence of an inband module in the segment where the port belongs to and to activation of the correlation process." ::= { prtRREntry 3 } prtRRSecurityEnable OBJECT-TYPE SYNTAX INTEGER { off(2), on(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This value indicates whether a security check should be performed. Setting this value to ON(3) will activate the security mechanism if and only if, the value of prtRRSecurityState is ACTIVE." ::= { prtRREntry 4 } prtRRSecurityMask OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Mask of the allowed MAC address that can be connected through this port. The security of the individual port overwrites the security of the segment where the port belongs to" ::= { prtRREntry 5 } prtRRSecurityPattern OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "A six-octet(48 bit) pattern, where the masked bits of prtRRSecurityMask should match the MAC address." ::= { prtRREntry 6} prtRRJitterAttenEnable OBJECT-TYPE SYNTAX INTEGER { unknown(1), off(2), on(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The value of this attribute determines activation of the jitters Attenuation mechanism of repeater's port ." ::= { prtRREntry 7 } prtRRConfigMsg OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Full configuration message coded in internal RAD application format. This entry describes port' configuration. " ::= { prtRREntry 8 } prtRRFlipAutoDisable OBJECT-TYPE SYNTAX INTEGER { noApplicable(1), off(2), on(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Attribute describing the control on the flipping mechanism of a lobe . Value ON indicates the ability of the lobe to auto disable itself when flipping occur. Value OFF indicates that the auto disable mechanism should not be activated and the lobe should stay in a flipping state. This attribute applies on selected lobes (tl-2/f, or tl-2/fsat)" ::= { prtRREntry 9 } prtRRSecurityMask2 OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Mask of the allowed MAC address that can be connected through this port. The security of the individual port overwrites the security of the segment where the port belongs to" ::= { prtRREntry 10 } prtRRSecurityPattern2 OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "A six-octet(48 bit) pattern: where the masked bits of prtRRSecurityMask2 should match the MAC address." ::= { prtRREntry 11 } prtRRMode OBJECT-TYPE SYNTAX INTEGER { noApplicable (1), smart-port (2), port (3), interRptrPort(4), multiConnPort(5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the port status of rr-sat card after the communication is broken. When configured to smart-port, the port disables itself when there is no management communication with attachment. interRptrPort - this port is used to connect an external repeater. No security can be set for this port. MAC Address is set to 0. No traps 'MAC Address changed' are generated. multiConnPort - this port is used for connection of external 4 port repeater. 8 securities per port exist. MAC Address is set to 0. No traps 'MAC Address changed' are generated. " ::= { prtRREntry 12 } prtRRAttachment OBJECT-TYPE SYNTAX INTEGER { none(1), station(2), sLau2(3), sLau4(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the type of the port attachment. Smart attachment types are applicable for rr-sat card only" ::= { prtRREntry 13 } -- --RADRing specific WAN modules port information -- prtMMTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtMMEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "RADRing specific WAN modules port information." ::= { prtRR 2 } prtMMEntry OBJECT-TYPE SYNTAX PrtMMEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table prtMMTable." INDEX { prtMMmdlID, prtMMID } ::= { prtMMTable 1 } PrtMMEntry ::= SEQUENCE { prtMMmdlID Integer32, prtMMID Integer32, prtMMAdminCmd INTEGER, prtMMOperStatus INTEGER, prtMMTestStatus INTEGER, prtMMBertResult INTEGER, prtMMTrapMaskEnable INTEGER } prtMMmdlID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier of the module(slot no.)this port is attached to." ::= { prtMMEntry 1 } prtMMID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier of the port (link) within its module." ::= { prtMMEntry 2 } prtMMAdminCmd OBJECT-TYPE SYNTAX INTEGER { normal(1), locLoop(2), remLoop(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting the object to locLoop(2) or remLoop(3) will activate the corresponding test. Value remLoop(3) activates the BERT test on the related link if mdlMMBertCmd is set to on(3). Setting parameter to normal(1), restores the normal operation of the link. The parameter is read-only when value of mdlRRMngState is disable" ::= { prtMMEntry 3 } prtMMOperStatus OBJECT-TYPE SYNTAX INTEGER { operational(1), locSyncLoss(2), remSyncLoss(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Reflects the Synchronization status. " ::= { prtMMEntry 4 } prtMMTestStatus OBJECT-TYPE SYNTAX INTEGER { normal(1), locLoop(2), remLoop(3), bert(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Reflects the link status. When the object is set to the value of bert(4), it means that the remote loopback is active too. " ::= { prtMMEntry 5 } prtMMBertResult OBJECT-TYPE SYNTAX INTEGER { unknown(1), fault(2), ok(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object indicates the status of the last BERT test." ::= { prtMMEntry 6 } prtMMTrapMaskEnable OBJECT-TYPE SYNTAX INTEGER { off(2), on(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "When this object is set to OFF by the management console, the agent starts sending the unmasked traps related to this module. Otherwise, no traps are sent by this module." ::= { prtMMEntry 7 } -- --RADRing specific Ethernet port information -- prtETTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtETEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "RADRing specific Ethernet port information" ::= { prtRR 3 } prtETEntry OBJECT-TYPE SYNTAX PrtETEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table prtETTable." INDEX { prtETmdlID, prtETID } ::= { prtETTable 1 } PrtETEntry ::= SEQUENCE { prtETmdlID Integer32, prtETID Integer32, prtETTrapMaskEnable INTEGER } prtETmdlID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier of the module, (slot no.), this port is attached to." ::= { prtETEntry 1 } prtETID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier of the port within its module." ::= { prtETEntry 2 } prtETTrapMaskEnable OBJECT-TYPE SYNTAX INTEGER { off(2), on(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "When this attribute is set to OFF by the management console, the agent starts sending the unmasked traps related to this port. Otherwise, no traps are sent by this port." ::= { prtETEntry 3 } -- -- RR Port Security Table (10.08.95) -- prtRRSecTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtRRSecEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "RR Port Security Table (10.08.95)" ::= { prtRR 4 } prtRRSecEntry OBJECT-TYPE SYNTAX PrtRRSecEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table prtRRSecTable." INDEX { prtRRSecmdlID, prtRRSecPrtID, prtRRSecID } ::= { prtRRSecTable 1 } PrtRRSecEntry ::= SEQUENCE { prtRRSecmdlID Integer32, prtRRSecPrtID Integer32, prtRRSecID Integer32, prtRRSecMask MacAddress, prtRRSecPattern MacAddress } prtRRSecmdlID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier of the module,(slot no.),this port is attached to." ::= { prtRRSecEntry 1 } prtRRSecPrtID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier of the port within its module." ::= { prtRRSecEntry 2 } prtRRSecID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier of the security number within the port." ::= { prtRRSecEntry 3 } prtRRSecMask OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Mask of the allowed MAC address that can be connected through this port. The security of the individual port overwrites the security of the segment, the port belongs to" ::= { prtRRSecEntry 4 } prtRRSecPattern OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "A six-octet(48 bit) pattern, where the masked bits of prtRRSecMask should match the MAC address." ::= { prtRRSecEntry 5} -- -- file :v:\doc\rdv\mib\Before~1\fdx.txt -- --Title: FDX MIB --Version: 2.1... --Date: 16.10.94 --By: Dan.R. --File: FDX.TXT --Comments: The FDX agent also supports the following Public MIBs: -- MIB-II (RFC1213) -- FDDI MIB (RFC 1285) -- relevant parts of Lannet-60 MIB. -- the RAD Station Group -- Implementation of the Station group is current -- for all manageable systems which support RAD Stations radFddiStation OBJECT IDENTIFIER ::= { radFddi 1 } radFddiStationsNumber OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of manageable Stations implemented in the box." ::= { radFddiStation 1 } -- the FDDI concentrator table radFddiStationTable OBJECT-TYPE SYNTAX SEQUENCE OF RadFddiStationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of FddiStation entries. The number of entries is given by the value of radFddiStationsNumber. " ::= { radFddiStation 2 } radFddiStationEntry OBJECT-TYPE SYNTAX RadFddiStationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table radFddiStationTable." INDEX { radFddiStationIndex } ::= { radFddiStationTable 1 } RadFddiStationEntry ::= SEQUENCE { radFddiStationIndex Integer32, radFddiStationType INTEGER, radFddiStationBus1TestResult INTEGER, radFddiStationBus2TestResult INTEGER, radFddiStationTempDeInsertAction INTEGER, radFddiStationPerformTest INTEGER, radFddiStationOpticalSwitchStatus -- was radFddiStationOpticalSwitchBypass INTEGER } radFddiStationIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value for each Station. Its value ranges between 1 and the value ofradFddiStationNumber." ::= { radFddiStationEntry 1 } radFddiStationType OBJECT-TYPE SYNTAX INTEGER { other(1), singleAttachedStation(2), dualAttachedStation(3), singleAttachedConcentrator(4), dualAttachedConcentrator(5), nullAttachedConcentrator(6) } MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates the type of the station." ::= { radFddiStationEntry 2 } radFddiStationBus1TestResult OBJECT-TYPE SYNTAX INTEGER { ok(1), faulty(2) } MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates the result of a test performed on Bus1." ::= { radFddiStationEntry 3 } radFddiStationBus2TestResult OBJECT-TYPE SYNTAX INTEGER { ok(1), faulty(2) } MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates the result of a test performed on Bus2." ::= { radFddiStationEntry 4 } radFddiStationTempDeInsertAction OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "This action provides temporary deinsertion of the root station from the ring. Expressed in milliseconds." ::= { radFddiStationEntry 5 } radFddiStationPerformTest OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "A value ON of this attribute indicates that a test should be performed upon the Station." ::= { radFddiStationEntry 6 } radFddiStationOpticalSwitchStatus OBJECT-TYPE SYNTAX INTEGER { on(1), off(2), notSupported(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "A value ON of this attribute indicates that the Station is in bypass mode." ::= { radFddiStationEntry 7 } -- the RAD FDDI SMT table radFddiSMTTable OBJECT-TYPE SYNTAX SEQUENCE OF RadFddiSMTEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of FddiSMT entries. The number of entries is given by the value of snmpFddiSMTNumber. " ::= { radFddi 2 } radFddiSMTEntry OBJECT-TYPE SYNTAX RadFddiSMTEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table radFddiSMTTable." INDEX { radFddiSMTIndex } ::= { radFddiSMTTable 1 } RadFddiSMTEntry ::= SEQUENCE { radFddiSMTIndex Integer32, radFddiSMTStation Integer32, radFddiSMTCFState INTEGER, radFddiSMTLeftSlot Integer32, radFddiSMTRightSlot Integer32 } radFddiSMTIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value for each SMT. Its value ranges between 1 and the value of snmpFddiSMTNumber." ::= { radFddiSMTEntry 1 } radFddiSMTStation OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Station inside the box to which the current SMT belongs. Its value ranges between 1 and the value of radFddiStationNumber." ::= { radFddiSMTEntry 2 } radFddiSMTCFState OBJECT-TYPE SYNTAX INTEGER { isolated(1), localA(2), localB(3), localAB(4), localS(5), wrapA(6), wrapB(7), wrapAB(8), wrapS(9), cWrapA(10), cWrapB(11), cWrapS(12), thru(13) } MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The attachement configuration for the Station. Extends the range of values provided by the SNMP variable snmpFddiSMTCFState from the SNMP FDDI MIB." ::= { radFddiSMTEntry 3 } radFddiSMTLeftSlot OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slot number of the leftmost card on the concentrator implemented inside the box and managed by the agent MAC." ::= { radFddiSMTEntry 4 } radFddiSMTRightSlot OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slot number of the rightmost card on the concentrator implemented inside the box and managed by the agent MAC. Note that the MAC-agent card itself is not taken into consideration." ::= { radFddiSMTEntry 5 } -- the RAD FDDI MAC table radFddiMACTable OBJECT-TYPE SYNTAX SEQUENCE OF RadFddiMACEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of FddiMAC entries. The number of entries is given by the value of snmpFddiMACNumber. " ::= { radFddi 3 } radFddiMACEntry OBJECT-TYPE SYNTAX RadFddiMACEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table radFddiMACTable." INDEX { radFddiMACSMTIndex, radFddiMACIndex } ::= { radFddiMACTable 1 } RadFddiMACEntry ::= SEQUENCE { radFddiMACSMTIndex Integer32, radFddiMACIndex Integer32, radFddiMACStation Integer32, radFddiMACTestResult Integer32, radFddiMACTokenCt Counter32, radFddiMACRingLoad Integer32, radFddiMACRingLoadBuffer OCTET STRING, radFddiMACRingLoadTrsh Integer32, radFddiMACRingLoadPeak Integer32, radFddiMACDownstreamNbr OCTET STRING, radFddiMACRingStatus INTEGER, radFddiMACRingUtilization Integer32, radFddiMACRingPeakUtilization Integer32 } radFddiMACSMTIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the SMT index associated with this MAC." ::= { radFddiMACEntry 1 } radFddiMACIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value for each MAC. Its value ranges between 1 and the value of snmpFddiMACNumber." ::= { radFddiMACEntry 2 } radFddiMACStation OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Station inside the box to which the current MAC belongs. Its value ranges between 1 and the value of radFddiStationNumber." ::= { radFddiMACEntry 3 } radFddiMACTestResult OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates the result of a test performed on MAC. The value is a sum. It takes the value 0 if the result of the test is OK and if faults occur, 2 raised to a power is added to the sum. The powers are according to the following table: Fault Power cardConfigError 0 GeneralError 1 MACError 2 " ::= { radFddiMACEntry 4 } radFddiMACTokenCt OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Token Counts - Refer to ANSI MAC {73}." ::= { radFddiMACEntry 5 } radFddiMACRingLoad OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Current traffic value. The traffic is expressed in percents of the maximum FDDI traffic in the range 1..20, expressed on a log(10) scale ( value = 10*log10(percent) )." ::= { radFddiMACEntry 6 } radFddiMACRingLoadBuffer OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Record of traffic for the last second with a resolution of 100 msec. The traffic is expressed in percents of the maximum FDDI traffic and each record contains 10 readings, in the range 1..20, expressed on a log(10) scale ( value = 10*log10(percent) )." ::= { radFddiMACEntry 7 } radFddiMACRingLoadTrsh OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Traffic threshold value. When exceeded, a trap is send to the management console. Expressed in percents of the maximum FDDI traffic, in the range 1..20, expressed on a log(10) scale." ::= { radFddiMACEntry 8 } radFddiMACRingLoadPeak OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Maximal traffic value since last reset of hub or relay. Expressed in per- cents of the maximum FDDI traffic, in the range 1..20, expressed on log(10) scale." ::= { radFddiMACEntry 9 } radFddiMACDownstreamNbr OBJECT-TYPE SYNTAX OCTET STRING (SIZE (6)) MAX-ACCESS read-only STATUS current DESCRIPTION "The MAC's downstream neighbor's long individual MAC address. The value shall be reported as '00 00 00 00 00 00' if it is unknown." ::= { radFddiMACEntry 10 } radFddiMACRingStatus OBJECT-TYPE SYNTAX INTEGER { ringUp(1), ringDown(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Attribute which summs the status of the ring controlled by the current MAC." ::= { radFddiMACEntry 11 } radFddiMACRingUtilization OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Current traffic value. The traffic is expressed in percents of the maximum FDDI traffic." ::= { radFddiMACEntry 12 } radFddiMACRingPeakUtilization OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Peak traffic value since las reset of the hub or relay. The traffic is expressed in percents of the maximum FDDI traffic." ::= { radFddiMACEntry 13 } -- the RAD FDDI Group table radFddiGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF RadFddiGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of FddiGroup entries. The number of entries is given by the value of snmpFddiGroupNumber. " ::= { radFddi 4 } radFddiGroupEntry OBJECT-TYPE SYNTAX RadFddiGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table radFddiGroupTable." INDEX { radFddiGroupId } ::= { radFddiGroupTable 1 } RadFddiGroupEntry ::= SEQUENCE { radFddiGroupId Integer32, radFddiGroupRedundancy INTEGER, radFddiGroupTopologyMode INTEGER, radFddiGroupTestResult INTEGER, radFddiGroupConfigStatus INTEGER, radFddiGroupAutoRightLoop INTEGER, radFddiGroupAutoLeftLoop INTEGER, radFddiGroupManRightLoop INTEGER, radFddiGroupManLeftLoop INTEGER, radFddiGroupOpticalSwitchStatus INTEGER } radFddiGroupId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Unique ID of the group in radFddiGroupTable. Equivalent to slot number in enclosures." ::= { radFddiGroupEntry 1 } radFddiGroupRedundancy OBJECT-TYPE SYNTAX INTEGER { none(1), double-bandwidth(2), backup(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute shows the usage of the A/B pair of ports in Tree mode. If the redundancy conditions are not fulfilled, value none(1) will be returned. If backup mode port A is a standby backup of port B, otherwise each of them is connected to a separate bus." ::= { radFddiGroupEntry 2 } radFddiGroupTopologyMode OBJECT-TYPE SYNTAX INTEGER { none(1), tree(2), ring(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Defines the topology mode of the FDDI PHY card." ::= { radFddiGroupEntry 3 } radFddiGroupTestResult OBJECT-TYPE SYNTAX INTEGER { ok(1), faulty(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Result of test performed upon an FDDI group. A value of faulty (1) indicates a CPU or communication at module level." ::= { radFddiGroupEntry 4 } radFddiGroupConfigStatus OBJECT-TYPE SYNTAX INTEGER { ok(1), cardConfigErrorAB(2), cardConfigErrorS(3), switchTopologyError(4) } MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates the configuration status of the module (group)." ::= { radFddiGroupEntry 5 } radFddiGroupAutoRightLoop OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Value ON of this attribute signifies that a hardware loop was automatically created on a FDDI module which does not sense the existence of another FDDI group on the right hand side." ::= { radFddiGroupEntry 6 } radFddiGroupAutoLeftLoop OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Value ON of this attribute signifies that a hardware loop was automatically created on a FDDI module which does not sense the existence of another FDDI group on the left hand side." ::= { radFddiGroupEntry 7 } radFddiGroupManRightLoop OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to ON signifies a command to the hardware to create a loop on the FDDI module which isolates the ring from the right hand side." ::= { radFddiGroupEntry 8 } radFddiGroupManLeftLoop OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to ON signifies a command to the hardware to create a loop on the FDDI module which isolates the ring from the left hand side." ::= { radFddiGroupEntry 9 } radFddiGroupOpticalSwitchStatus OBJECT-TYPE SYNTAX INTEGER { not-present(1), inserted(2), not-inserted(3), present(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute describes the presence of the optical switch and for existing optical switches describes the possibility of auto-reconfiguration of path resources (MACs and M-ports) in the case of bus fault or connection disabling. If merge(2), resources will try to move to another bus, if non-merge(1) resources are left on their dedicated bus." ::= { radFddiGroupEntry 10 } radFddiPortTable OBJECT-TYPE SYNTAX SEQUENCE OF RadFddiPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "." ::= { radFddi 5 } radFddiPortEntry OBJECT-TYPE SYNTAX RadFddiPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table radFddiPortTable." INDEX { radFddiPortGroupID, radFddiPortID } ::= { radFddiPortTable 1 } RadFddiPortEntry ::= SEQUENCE { radFddiPortGroupID Integer32, radFddiPortID Integer32, radFddiPortTestResult INTEGER, radFddiPortNumberOfConnectedStations Integer32, radFddiPortConnectedStations OCTET STRING, radFddiPortCurrentPath INTEGER, radFddiPortFunctionalStatus INTEGER } radFddiPortGroupID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "ID of group to which the FDDI card belongs." ::= { radFddiPortEntry 1 } radFddiPortID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Unique Id of the port in the radFddiPortEntry." ::= { radFddiPortEntry 2 } radFddiPortTestResult OBJECT-TYPE SYNTAX INTEGER { ok(1), faulty(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the result of a test performed on a port." ::= { radFddiPortEntry 4 } radFddiPortNumberOfConnectedStations OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of stations connected to the port." ::= { radFddiPortEntry 5 } radFddiPortConnectedStations OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute displays the configuration of the stations connected to the port.The FDDI addresses of the stations are displayed in ring order, starting with the address of the first station connected to the port. The length of the string is equal to the value of radFddiPortNumberOfConnectedStations multiplied by 8 (length of FddiSMTStationIdType)." ::= { radFddiPortEntry 6 } radFddiPortCurrentPath OBJECT-TYPE SYNTAX INTEGER{ isolated(1), local(2), secondary(3), primary(4), concatenated(5), thru(6) } MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Current Path in FDDI port on PHY cards." ::= { radFddiPortEntry 8 } radFddiPortFunctionalStatus OBJECT-TYPE SYNTAX INTEGER{ ok(1), lerAlarm(2), lerCutoff(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Fubctional status of the port according to value of link error estimate relative to thresholds of alarm and cutoff." ::= { radFddiPortEntry 9 } radFddiAgn OBJECT IDENTIFIER ::= { radFddi 6 } -- the RAD Agent Group -- Implementation of the Agent group is current -- for all manageable systems which support RAD Stations radFddiAgnPriSwDesc OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "ASCII string for description and display of the Fddi agent software version." ::= { radFddiAgn 1 } -- -- file :v:\doc\rdv\mib\ver485\brggen.txt -- --Version: 4.0 --Date: 16.10.94 --By: Debby Koren & Orly Nicklass --File: BRGgen.txt --Last Updated by Ilana Schvetz 09-Jan-2002. genBridge OBJECT IDENTIFIER ::= {radBridges 1 } -- At the end of the MIB there is a definition of all RAD general traps for bridges. radBridgeAction OBJECT-TYPE SYNTAX INTEGER { reset(1), sendNetworkTab(2), deleteNetworkTab(3), sendRoutingTab(4), -- Level II deleteRoutinTab(5), sendLanTab(6), deleteLanTab(7), deleteArpTab(8), sendArpTab(9), deleteRouteTab(10), -- Level III sendRouteTab(11), deactivateAllMasks(12), saveAllActiveMasks(13), loadAndActivateAllMasksFromNVRAM(14), clearAllMasksFromNVRAM(15), defaultConfig(16), resetNVRAM(17), clearIPNVRAM(18), noOp(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable enables the operator to perform one of the specified actions on the tables maintained by the network device. Send actions are not currently implemented. Not all actions can be performed on all bridges." ::= { genBridge 1 } radBridgeInactiveArpTimeOut OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable defines the maximum time period that can pass between ARP requests concerning an entry in the ARP table. After this time period, the entry is deleted from the table." ::= { genBridge 2 } -- radBridgeMaskTab defines the format of RAD Bridge OLD masking tables radBridgeMaskTable OBJECT-TYPE SYNTAX SEQUENCE OF RadBridgeMaskEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Mask tables enable definition of forwarding restrictions and control of message flow in the internetwork. Each entry in this table defines a mask statement consisting of up to three mask definitions and an action defined by radBridgeMaskOper. Different types of mask entries are supported, as defined by radBridgeMaskType." ::= { genBridge 3 } radBridgeMaskEntry OBJECT-TYPE SYNTAX RadBridgeMaskEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table radBridgeMaskTable." INDEX { radBridgeMaskType, radBridgeMaskIfIndex, radBridgeMaskNum } ::= { radBridgeMaskTable 1 } RadBridgeMaskEntry ::= SEQUENCE { radBridgeMaskType INTEGER, radBridgeMaskIfIndex Integer32, radBridgeMaskNum Integer32, radBridgeMaskDest INTEGER, radBridgeMaskPat1 OCTET STRING, radBridgeMaskActiveBit1 OCTET STRING, radBridgeMaskFrom1 INTEGER, radBridgeMaskOffset1 Integer32, radBridgeMaskCond1 INTEGER, radBridgeMaskPat2 OCTET STRING, radBridgeMaskActiveBit2 OCTET STRING, radBridgeMaskFrom2 INTEGER, radBridgeMaskOffset2 Integer32, radBridgeMaskCond2 INTEGER, radBridgeMaskPat3 OCTET STRING, radBridgeMaskActiveBit3 OCTET STRING, radBridgeMaskFrom3 INTEGER, radBridgeMaskOffset3 Integer32, radBridgeMaskCond3 INTEGER, radBridgeMaskOper INTEGER } radBridgeMaskType OBJECT-TYPE SYNTAX INTEGER { tx(1), rx(2), compress(3), priority(4), loadSharing(5), facs(6), codConnect(7), codDisconnect(8) } MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the type of mask entry." ::= { radBridgeMaskEntry 1 } radBridgeMaskIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the if Index of the interface to which the mask is applied." ::= { radBridgeMaskEntry 2 } radBridgeMaskNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The Mask entry number, defined by its line number in the mask table." ::= { radBridgeMaskEntry 3 } radBridgeMaskDest OBJECT-TYPE SYNTAX INTEGER { unassigned-cond (1), broadcast-msge (2), multicast-msge (3), all-msge(4), none(5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the type of destination address carried by the frame to which the mask will be applied. Unassigned-condition deactivates the mask entry." ::= { radBridgeMaskEntry 4 } radBridgeMaskPat1 OBJECT-TYPE SYNTAX OCTET STRING -- (SIZE (2)) MAX-ACCESS read-write STATUS current DESCRIPTION "Describes the mask field which is either a 16 bit binary pattern, or four digit hexadecimal pattern." ::= { radBridgeMaskEntry 5 } radBridgeMaskActiveBit1 OBJECT-TYPE SYNTAX OCTET STRING -- (SIZE (2)) MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the positions of the wild card characters (*) in the radBridgeMaskPat1 field." ::= { radBridgeMaskEntry 6 } radBridgeMaskFrom1 OBJECT-TYPE SYNTAX INTEGER { mac(1), llc(2), net(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Offset base of radBridgeMaskPat1 within the frame. Net can be in some cases the data start point." ::= { radBridgeMaskEntry 7 } radBridgeMaskOffset1 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the radBridgeMaskPat1 offset within the frame (in bytes) from the base defined in by radBridgeMaskForm1.The mask offset is an even decimal number in the range of 0 to 1518." ::= { radBridgeMaskEntry 8 } radBridgeMaskCond1 OBJECT-TYPE SYNTAX INTEGER { false (1), true (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the logical condition of the mask pattern: true - Condition is valid if at the position specified by radBridgeMaskOffset1 the packet contains data that matches the content of radBridgeMaskPat1. false - Condition is valid if at the position specified by radBridgeMaskOffset1 the packet contains data that does not match the content of radBridgeMaskPat1." ::= { radBridgeMaskEntry 9 } radBridgeMaskPat2 OBJECT-TYPE SYNTAX OCTET STRING -- (SIZE (2)) MAX-ACCESS read-write STATUS current DESCRIPTION "Describes the mask field which is either a 16 bit binary pattern, or four digit hexadecimal pattern." ::= { radBridgeMaskEntry 10 } radBridgeMaskActiveBit2 OBJECT-TYPE SYNTAX OCTET STRING -- (SIZE (2)) MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the positions of the wild card characters (*) in the radBridgeMaskPat2 field." ::= { radBridgeMaskEntry 11 } radBridgeMaskFrom2 OBJECT-TYPE SYNTAX INTEGER { mac (1), llc (2), net(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Offset base of radBridgeMaskPat2 within the frame. Net can be in some cases the data start point." ::= { radBridgeMaskEntry 12 } radBridgeMaskOffset2 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the radBridgeMaskPat2 offset within the frame (in bytes) from the base defined in by radBridgeMaskForm2.The mask offset is an even decimal number in the range of 0 to 1518." ::= { radBridgeMaskEntry 13 } radBridgeMaskCond2 OBJECT-TYPE SYNTAX INTEGER { false (1), true (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the logical condition of the mask pattern: true - Condition is valid if at the position specified by radBridgeMaskOffset2 the packet contains data that matches the content of radBridgeMaskPat2. false - Condition is valid if at the position specified by radBridgeMaskOffset2 the packet contains data that does not match the content of radBridgeMaskPat2." ::= { radBridgeMaskEntry 14 } radBridgeMaskPat3 OBJECT-TYPE SYNTAX OCTET STRING -- (SIZE (2)) MAX-ACCESS read-write STATUS current DESCRIPTION "Describes the mask field which is either a 16 bit binary pattern, or four digit hexadecimal pattern." ::= { radBridgeMaskEntry 15 } radBridgeMaskActiveBit3 OBJECT-TYPE SYNTAX OCTET STRING -- (SIZE (2)) MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the positions of the wild card characters (*) in the radBridgeMaskPat3 field." ::= { radBridgeMaskEntry 16 } radBridgeMaskFrom3 OBJECT-TYPE SYNTAX INTEGER { mac (1), llc (2), net (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Offset base of radBridgeMaskPat3 within the frame. Net can be in some cases the data start point." ::= { radBridgeMaskEntry 17 } radBridgeMaskOffset3 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the radBridgeMaskPat3 offset within the frame (in bytes) from the base defined in by radBridgeMaskForm3. The mask offset is an even decimal number in the range of 0 to 1518." ::= { radBridgeMaskEntry 18 } radBridgeMaskCond3 OBJECT-TYPE SYNTAX INTEGER { false (1), true (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the logical condition of the mask pattern: true - Condition is valid if at the position specified by radBridgeMaskOffset3 the packet contains data that matches the content of radBridgeMaskPat3 false - Condition is valid if at the position specified by radBridgeMaskOffset3 the packet contains data that does not match the content of radBridgeMaskPat3." ::= { radBridgeMaskEntry 19 } radBridgeMaskOper OBJECT-TYPE SYNTAX INTEGER { block (1), forward (2), route (3), forward-route (4), high-priority (5), noOp(6), delete(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "The type of action to be taken if the frame meets the conditions of the mask. noOp = disabled (mask remains on list, but is not active) delete = mask is removed from the list. " ::= { radBridgeMaskEntry 20 } radBridgeCOD OBJECT IDENTIFIER ::= {genBridge 4 } radBridgeCODParamTable OBJECT-TYPE SYNTAX SEQUENCE OF RadBridgeCODEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of COD parameters " ::= { radBridgeCOD 1} radBridgeCODEntry OBJECT-TYPE SYNTAX RadBridgeCODEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each radBridgeCODEntry consists of the following parameters" INDEX {radBridgeCODIfIndex} ::= { radBridgeCODParamTable 1 } RadBridgeCODEntry ::= SEQUENCE { radBridgeCODIfIndex Integer32, radBridgeCODManualConnect INTEGER, radBridgeCODMode INTEGER, radBridgeCODConnectDelay Integer32, radBridgeCODisConnectDelay Integer32, radBridgeCODImplicitSwitch INTEGER, radBridgeCODNumAccess Counter32, radBridgeCODTotalConnecTime Integer32 } radBridgeCODIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The interface to which this COD entry is applicable." ::= { radBridgeCODEntry 1 } radBridgeCODManualConnect OBJECT-TYPE SYNTAX INTEGER { connect(1), disconnect(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The management station can start connection manually by setting this parameter" ::= { radBridgeCODEntry 2 } radBridgeCODMode OBJECT-TYPE SYNTAX INTEGER { answer(1), originate(2), disable(3), answerAndOriginate(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "In answer mode only one incoming call may be accepted at a time. Other nodes attempting to access the local modem will receive a busy signal until the connection is terminated. (Answer mode has no difficulty supporting multiple remote connections to one local port, as blocking multiple incoming calls is just a modem function. Originate mode, on the other hand will only support a single local port to remote port connection). The disable parameter disables the COD utility for this interface. Choosing any other mode will enable the COD utility." ::= { radBridgeCODEntry 3 } radBridgeCODConnectDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The connect delay defines the minimum time period that the link must stay disconnected, between 2 succesive connections (in seconds)." ::= { radBridgeCODEntry 4 } radBridgeCODisConnectDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The disconnect delay defines the minimum time period the link must stay connected, between 2 succesive disconnections (in seconds)." ::= { radBridgeCODEntry 5 } radBridgeCODImplicitSwitch OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The inplicit switch allows the user to ignore implicit triggers provided by the COD software." -- DEFVAL { 1 } ::= { radBridgeCODEntry 6 } radBridgeCODNumAccess OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of successful connections that have been established since the COD has been reset." ::= { radBridgeCODEntry 7} radBridgeCODTotalConnecTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The sum of all the connect time intervals since the COD was reset." ::= { radBridgeCODEntry 8} radBridgeCODTimeTriggerTable OBJECT-TYPE SYNTAX SEQUENCE OF RadBridgeCODTimeTriggerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of COD parameters " ::= { radBridgeCOD 2 } radBridgeCODTimeTriggerEntry OBJECT-TYPE SYNTAX RadBridgeCODTimeTriggerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each radBridgeCODTimeTriggerEntry consists of the following parameters" INDEX { radBridgeCODTimeIfIndex, radBridgeCODDay, radBridgeCODTimeTriggerNum } ::= { radBridgeCODTimeTriggerTable 1 } RadBridgeCODTimeTriggerEntry ::= SEQUENCE { radBridgeCODTimeIfIndex Integer32, radBridgeCODDay INTEGER, radBridgeCODTimeTriggerNum Integer32, radBridgeCODTimeTriggerFrom DisplayString, radBridgeCODTimeTriggerTo DisplayString, radBridgeCODTimeTriggerStatus INTEGER } radBridgeCODTimeIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The interface to which this COD Time Trigger entry is applicable." ::= { radBridgeCODTimeTriggerEntry 1} radBridgeCODDay OBJECT-TYPE SYNTAX INTEGER { mon(1), tue(2), wed(3), thu(4), fri(5), sat(6), sun(7) } MAX-ACCESS read-only STATUS current DESCRIPTION " The day of the week in which the dial up connection operates." ::= { radBridgeCODTimeTriggerEntry 2 } radBridgeCODTimeTriggerNum OBJECT-TYPE SYNTAX Integer32 (1..3) MAX-ACCESS read-only STATUS current DESCRIPTION " Every day of the week the user can configure 3 dial up connections." ::= { radBridgeCODTimeTriggerEntry 3 } radBridgeCODTimeTriggerFrom OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Time to start Dial Up connection, in format hh:mm." ::= {radBridgeCODTimeTriggerEntry 4 } radBridgeCODTimeTriggerTo OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Time to terminate Dial Up connection, in format HH:MM." ::= {radBridgeCODTimeTriggerEntry 5 } radBridgeCODTimeTriggerStatus OBJECT-TYPE SYNTAX INTEGER { valid(1), invalid(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The status of a table entry." ::= { radBridgeCODTimeTriggerEntry 6 } radBridgeCODTraffic OBJECT IDENTIFIER ::= { radBridgeCOD 3} radBridgeCODTrafficTable OBJECT-TYPE SYNTAX SEQUENCE OF RadBridgeCODTrafficEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of COD Traffic trigger " ::= { radBridgeCODTraffic 1 } radBridgeCODTrafficEntry OBJECT-TYPE SYNTAX RadBridgeCODTrafficEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each radBridgeCODTrafficEntry consists of the following parameters." INDEX {radBridgeCODProtocolType} ::= { radBridgeCODTrafficTable 1} RadBridgeCODTrafficEntry ::= SEQUENCE { radBridgeCODProtocolType INTEGER, radBridgeCODTrafficTriggerStatus INTEGER } radBridgeCODProtocolType OBJECT-TYPE SYNTAX INTEGER { ip(1), ipx(2), other(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The Protocol Type of the Traffic Table" ::= { radBridgeCODTrafficEntry 1 } radBridgeCODTrafficTriggerStatus OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Command of Status of the Protocol Traffic Trigger" ::= { radBridgeCODTrafficEntry 2 } radBridgeCODRemoteIPAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION " This is the Remote IP Address" ::= { radBridgeCODTraffic 2 } radBridgeCODIPMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION " This is the Mask of the Remote IP Address" ::= { radBridgeCODTraffic 3 } radBridgeCODTrafficTriggerProtType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Protocol Type for the User Defined Protocol Traffic Trigger (3)." ::= { radBridgeCODTraffic 4 } --COD Condition table radBridgeCODCondTable OBJECT-TYPE SYNTAX SEQUENCE OF RadBridgeCODCondEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of COD Condition parameters " ::= { radBridgeCOD 4} radBridgeCODCondEntry OBJECT-TYPE SYNTAX RadBridgeCODCondEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each radBridgeCODCondEntry consists of the following parameters" INDEX {radBridgeCODCondIfIndex} ::= { radBridgeCODCondTable 1 } RadBridgeCODCondEntry ::= SEQUENCE { radBridgeCODCondIfIndex Integer32, radBridgeCODOriginateConnectCondition INTEGER, radBridgeCODOriginateDisConnectCondition INTEGER, radBridgeCODOriginateDisConnectDelay Integer32, radBridgeCODAnswerConnectCondition INTEGER, radBridgeCODSpecificOnTrafficOIDCondition OBJECT IDENTIFIER, radBridgeCODDisConnectMinimunFramesNumber Integer32 } radBridgeCODCondIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The interface, this COD entry is applicable to." ::= { radBridgeCODCondEntry 1 } radBridgeCODOriginateConnectCondition OBJECT-TYPE SYNTAX INTEGER { onPowerOn (1), whenAnyStationOnLan (2), onTraffic (3), onManualConnect (4) } MAX-ACCESS read-write STATUS current DESCRIPTION " This condition, allows the user to specify the condition under which the link is connected. The options are onPowerOn - On power on. whenAnyStationOnLan - When any station on lan. onTraffic - On traffic. The user can specify the condition/s for connection. The connection will be defined in CODSpecificOnTrafficConditionOID . onManualConnect - depends on radBridgeCODManualConnect OBJECT-TYPE (=connect). " ::= { radBridgeCODCondEntry 2 } radBridgeCODOriginateDisConnectCondition OBJECT-TYPE SYNTAX INTEGER { noStationOnLan (1), onTraffic (2), onDelayFromConnectionOnRequest (3), onManualDisConnect (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This condition allows the user to specify the condition under which the link is disconnected. The options are: noStationOnLan - When there is no station on lan. Counts 15 minutes from the point the last frame from lan has been received. If no frame have been transmitted on lan by the end of this period, disconnect the connection. onTraffic - On traffic. The user can specify the condition/s for disconnection. The disconnection will be defined in CODSpecificOnTrafficConditionOID . onDelayFromConnectionOnRequest - On Delay From Connection On Request . The delay time period will be defined in CODOriginateDisConnectDelay . onManualDisConnect - depends on radBridgeCODManualConnect OBJECT-TYPE (=disconnect). " ::= { radBridgeCODCondEntry 3 } radBridgeCODOriginateDisConnectDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Delay time in seconds. " ::= { radBridgeCODCondEntry 4 } radBridgeCODAnswerConnectCondition OBJECT-TYPE SYNTAX INTEGER { onPowerOn (1), whenAnyStationOnLan (2), onTraffic (3), onManualConnect (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "CODCondAnswerConnect allows the user to specify the condition under which the link is connected. The options are: onPowerOn - On power on. whenAnyStationOnLan - When any station on lan. onTraffic - On traffic. The user can specify the condition/s for connection. The connection will be defined in CODSpecificOnTrafficConditionOID . onManualConnect - depends on radBridgeCODManualConnect OBJECT-TYPE . " ::= { radBridgeCODCondEntry 5 } radBridgeCODSpecificOnTrafficOIDCondition OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION "A reference to a specific entry in the radBridgeMaskTable, which describes the particular COD condition . If Connect or Disconnect Conditions are not onTraffic, its value should be set to the OBJECT IDENTIFIER { 0 0 }. " ::= { radBridgeCODCondEntry 6 } radBridgeCODDisConnectMinimunFramesNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Frames rate." ::= { radBridgeCODCondEntry 7 } --The IPX following objects define the Spoofing radBridgeIPX OBJECT IDENTIFIER ::= {genBridge 5 } radBridgeIPXdriver OBJECT IDENTIFIER ::= {radBridgeIPX 1 } radBridgeIPXRip OBJECT IDENTIFIER ::= {radBridgeIPX 2 } radBridgeIPXSap OBJECT IDENTIFIER ::= {radBridgeIPX 3 } radBridgeIPXForwarding OBJECT-TYPE SYNTAX INTEGER { forwarding(1), not-forwarding(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The indication of whether this entity is acting as an IPX gateway in respect to the forwarding of datagrams received by, but not addressed to, this entity. IPX gateways forward datagrams. IPX hosts do not. Note that changing this parameter requiers RESET of the router." -- DEFVAL { 1 } ::= { radBridgeIPXdriver 1 } radBridgeIPXRipOutPackets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of packets transmitted by RIP." ::= { radBridgeIPXRip 1 } radBridgeIPXRipInPackets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of packets received by RIP. This will include any packets that are subsequently discarded." ::= { radBridgeIPXRip 2 } radBridgeIPXRipInDiscards OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of received packets discarded by RIP." ::= { radBridgeIPXRip 3 } radBridgeIPXRipTblNoOfEntries OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The max number of entries that exist in the RIP routing table." ::= { radBridgeIPXRip 4 } radBridgeIPXRipTblBcastTrigUpdateInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The default time interval (in seconds)between triggered RIP updates on a broadcast type interface. A triggered update occurs when a change is detected in the routing database. This time interval delays the broadcasting of these updates so that changes on the network will not result in a lot of triggered updates." ::= { radBridgeIPXRip 5 } radBridgeIPXRipTable OBJECT-TYPE SYNTAX SEQUENCE OF RadBridgeIPXRipTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The routing table used by RIP to calculate routes to remote desination networks." ::= { radBridgeIPXRip 6 } radBridgeIPXRipTableEntry OBJECT-TYPE SYNTAX RadBridgeIPXRipTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The routing information for one of this entity's destination networks." INDEX { radBridgeIPXRipDestNetwork, radBridgeIPXRipPolicy } ::= { radBridgeIPXRipTable 1 } RadBridgeIPXRipTableEntry ::= SEQUENCE { radBridgeIPXRipDestNetwork OCTET STRING (SIZE(4)), radBridgeIPXRipPolicy INTEGER, radBridgeIPXRipForwardingRouter OCTET STRING (SIZE(6)), radBridgeIPXRipNIC Integer32, radBridgeIPXRipTickMetric Integer32, radBridgeIPXRipHopMetric Integer32, radBridgeIPXRipAgingTime TimeTicks, radBridgeIPXRipValueStatus INTEGER, radBridgeIPXRipForwardType INTEGER } radBridgeIPXRipDestNetwork OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) MAX-ACCESS read-only STATUS current DESCRIPTION "The destination network address to which this entry's routing information pertains." ::= {radBridgeIPXRipTableEntry 1 } radBridgeIPXRipPolicy OBJECT-TYPE SYNTAX INTEGER { main(1), alternate(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "A value specifying the precidence of the route. A value of zero means that the route is the best route, a value of one means that the route is the second best route and so on." ::= { radBridgeIPXRipTableEntry 2 } radBridgeIPXRipForwardingRouter OBJECT-TYPE SYNTAX OCTET STRING (SIZE(6)) MAX-ACCESS read-write STATUS current DESCRIPTION "The IPX node address of the next hop (router) for the entry's associated destination network." ::= { radBridgeIPXRipTableEntry 3 } radBridgeIPXRipNIC OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "An interface identifier specifying what IPX interface the next hop can be found on." ::= { radBridgeIPXRipTableEntry 4 } radBridgeIPXRipTickMetric OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The metric, in terms of transit time, associated with the route given by the entry. This time is in terms of 1/18ths of a second." ::= { radBridgeIPXRipTableEntry 5 } radBridgeIPXRipHopMetric OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The metric, in terms of distance , associated with the route given by the entry." ::= { radBridgeIPXRipTableEntry 6 } radBridgeIPXRipAgingTime OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "The last time that the entry was updated. The time will be provided in terms of the MIB-I object sysUpTime." ::= {radBridgeIPXRipTableEntry 7 } radBridgeIPXRipValueStatus OBJECT-TYPE SYNTAX INTEGER { static(1), dynamic(2), invalid(3), semiDynamic(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The entry status value; whether the entry is permanent (added statically), reachable or unreachable. In the latter two cases it would be added by RIP. A semiDynamic entry is an entry enterd manualy by the user and can be updated by the router." ::= { radBridgeIPXRipTableEntry 8 } radBridgeIPXRipForwardType OBJECT-TYPE SYNTAX INTEGER { other (1), -- not specified by this MIB local (2), -- local interface remote (3) -- remote destination } MAX-ACCESS read-write STATUS current DESCRIPTION "The type of route. Note that local(2) refers to a route for which the next hop is the final destination; remote(3) refers to a route for which the next hop is not the final destination." ::= {radBridgeIPXRipTableEntry 9 } radBridgeIPXRipInfTable OBJECT-TYPE SYNTAX SEQUENCE OF RadBridgeIPXRipInfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The RIP interface table." ::= { radBridgeIPXRip 7 } radBridgeIPXRipInfEntry OBJECT-TYPE SYNTAX RadBridgeIPXRipInfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry corresponds to one ifindex." INDEX { radBridgeIPXRipInfIfIndex} ::= { radBridgeIPXRipInfTable 1 } RadBridgeIPXRipInfEntry ::= SEQUENCE { radBridgeIPXRipInfIfIndex Integer32, radBridgeIPXRipInfBcastUpdate Integer32, radBridgeIPXRipInfAgeMultiplier Integer32 } radBridgeIPXRipInfIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This value of Ifindex is same as radBridgeIPXIfIndex in the IPX Interface Table." ::= { radBridgeIPXRipInfEntry 1 } radBridgeIPXRipInfBcastUpdate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The RIP periodic update interval, in seconds. Zero value corresponds to infinite interval." -- DEFVAL {60} ::= { radBridgeIPXRipInfEntry 2 } radBridgeIPXRipInfAgeMultiplier OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The holding multiplier for information received in RIP periodic updates. Zero value corresponds to infinite aging time." -- DEFVAL {3} ::= { radBridgeIPXRipInfEntry 3 } radBridgeIPXSapOutPackets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of packets transmitted by SAP." ::= { radBridgeIPXSap 1 } radBridgeIPXSapInPackets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of packets received by SAP. This will include any packets that are subsequently discarded." ::= { radBridgeIPXSap 2 } radBridgeIPXSapInDiscards OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of received packets discarded by SAP." ::= { radBridgeIPXSap 3 } radBridgeIPXSapTblNoOfEntries OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The max number of entries that exist in the SAP Server Information table." ::= { radBridgeIPXSap 4 } radBridgeIPXSapTblBcastTrigUpdateInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The default time interval (in seconds) between triggered SAP updates on a broadcast style interface. A triggered update occurs when a change is detected in the service database. This time interval delays the transmission of these updates so that changes on the network will not result in a lot of triggered updates." ::= { radBridgeIPXSap 5 } radBridgeIPXSapTable OBJECT-TYPE SYNTAX SEQUENCE OF RadBridgeIPXSapTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Server Information table is used by SAP to store information of services which are available on the internetwork." ::= { radBridgeIPXSap 6 } radBridgeIPXSapTableEntry OBJECT-TYPE SYNTAX RadBridgeIPXSapTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The server information for one of this entity's server entries." INDEX { radBridgeIPXSapServerType, radBridgeIPXSapName } ::= { radBridgeIPXSapTable 1 } RadBridgeIPXSapTableEntry ::= SEQUENCE { radBridgeIPXSapServerType Integer32, radBridgeIPXSapName DisplayString (SIZE(48)), radBridgeIPXSapNetwork OCTET STRING (SIZE(4)), radBridgeIPXSapNode OCTET STRING (SIZE(6)), radBridgeIPXSapSocket Integer32, radBridgeIPXSapHopsToServer Integer32, radBridgeIPXSapNIC Integer32, radBridgeIPXSapAgingTime TimeTicks, radBridgeIPXSapStatus INTEGER } radBridgeIPXSapServerType OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The type of the server for which this entry pertains." ::= { radBridgeIPXSapTableEntry 1 } radBridgeIPXSapName OBJECT-TYPE SYNTAX DisplayString (SIZE(48)) MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the server for which this entry pertains." ::= { radBridgeIPXSapTableEntry 2 } radBridgeIPXSapNetwork OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) MAX-ACCESS read-write STATUS current DESCRIPTION "The IPX network address of the host on which this server exists." ::= { radBridgeIPXSapTableEntry 3 } radBridgeIPXSapNode OBJECT-TYPE SYNTAX OCTET STRING (SIZE(6)) MAX-ACCESS read-write STATUS current DESCRIPTION "The IPX node address of the host on which this server exists." ::= { radBridgeIPXSapTableEntry 4 } radBridgeIPXSapSocket OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The IPX socket number that is being used by the server to which this entry pertains." ::= { radBridgeIPXSapTableEntry 5 } radBridgeIPXSapHopsToServer OBJECT-TYPE SYNTAX Integer32 (1..16) MAX-ACCESS read-write STATUS current DESCRIPTION "The number of hops to the entity on which this server exists." ::= { radBridgeIPXSapTableEntry 6 } radBridgeIPXSapNIC OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "An Network Interface Card identifier specifying what IPX interface the next hop can be found on." ::= { radBridgeIPXSapTableEntry 7 } radBridgeIPXSapAgingTime OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "The last time that the entry was updated. The time will be provided in terms of the MIB-I object sysUpTime." ::= { radBridgeIPXSapTableEntry 8 } radBridgeIPXSapStatus OBJECT-TYPE SYNTAX INTEGER { permanent(1), dynamic(2), invalid(3), semiDynamic(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The status of the entry." ::= { radBridgeIPXSapTableEntry 9 } radBridgeIPXSapInfTable OBJECT-TYPE SYNTAX SEQUENCE OF RadBridgeIPXSapInfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Sap interface table." ::= { radBridgeIPXSap 7 } radBridgeIPXSapInfEntry OBJECT-TYPE SYNTAX RadBridgeIPXSapInfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry corresponds to one ifindex." INDEX {radBridgeIPXSapInfIfIndex} ::= { radBridgeIPXSapInfTable 1 } RadBridgeIPXSapInfEntry ::= SEQUENCE { radBridgeIPXSapInfIfIndex Integer32, radBridgeIPXSapInfBcastUpdate Integer32, radBridgeIPXSapInfAgeMultiplier Integer32 } radBridgeIPXSapInfIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This value of Ifindex is same as radBridgeIPXIfIndex in the IPX Interface Table." ::= { radBridgeIPXSapInfEntry 1 } radBridgeIPXSapInfBcastUpdate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The SAP periodic update interval, in seconds. Zero value corresponds to infinite interval." -- DEFVAL {60} ::= { radBridgeIPXSapInfEntry 2 } radBridgeIPXSapInfAgeMultiplier OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The holding multiplier for information received in SAP periodic updates. Zero value corresponds to infinite aging time." -- DEFVAL {3} ::= { radBridgeIPXSapInfEntry 3 } -- radMaskingTab defines the new format of RAD Bridge masking tables GenAddress ::= OCTET STRING (SIZE(12)) newMasking OBJECT IDENTIFIER ::= {genBridge 6 } maskingMaxEntries OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of entries in the masking table." ::= { newMasking 1 } maskingCurrentEntries OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of entries in the mask table." ::= { newMasking 2 } maskingTable OBJECT-TYPE SYNTAX SEQUENCE OF MaskingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is the new masking scheme. Mask tables enable definition of forwarding restrictions and control of message flow in the internetwork. Each entry in this table defines a mask statement and an action defined by maskingOperation." ::= { newMasking 3 } maskingEntry OBJECT-TYPE SYNTAX MaskingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in the mask table." INDEX { maskingType, maskingIfIndex, maskingIndex } ::= { maskingTable 1 } MaskingEntry ::= SEQUENCE { maskingType INTEGER, maskingIfIndex Integer32, maskingIndex Integer32, maskingProtocolType INTEGER, maskingSmartMaskOID OBJECT IDENTIFIER, maskingFrameType INTEGER, maskingFrameTypeCondition INTEGER, maskingSourceAddress GenAddress, maskingSourceActiveBits GenAddress, maskingSourceMacOrNet INTEGER, maskingSourceCondition INTEGER, maskingDestAddress GenAddress, maskingDestActiveBits GenAddress, maskingDestMacOrNet INTEGER, maskingDestCondition INTEGER, maskingLowLevelProt INTEGER, maskingLowLevelProtCondition INTEGER, maskingHighLevelProt Integer32, maskingHighLevelProtCondition INTEGER, maskingPortNum Integer32, maskingPortNumCondition INTEGER, maskingOperation INTEGER, maskingSrcPortNum Integer32, maskingSrcPortNumCondition INTEGER } maskingType OBJECT-TYPE SYNTAX INTEGER { tx (1), rx (2), compress(3), priority(4), loadSharing(5), facs(6), codConnect(7), codDisconnect(8) } MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the type of mask entry. " ::= { maskingEntry 1 } maskingIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the ifIndex of the interface to which the mask is applied." ::= { maskingEntry 2 } maskingIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "An index to the masking table. This number should not be greater than maskingMaxEntries" ::= { maskingEntry 3 } maskingProtocolType OBJECT-TYPE SYNTAX INTEGER { unknown (1), ip (2), ipx (3), sna (4), netbios (5), apple (6), dec (7), all (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "The base protocol for masking. IPX, IP, others." ::= { maskingEntry 4 } maskingSmartMaskOID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION "A reference to a specific Smart mask table (old radBridgeMaskTable) which enables a more specific mask type. If this information is not available, its value should be set to the OBJECT IDENTIFIER { 0 0 }. " ::= { maskingEntry 5 } maskingFrameType OBJECT-TYPE SYNTAX INTEGER { unknown (1), all (2), broadcast (3), multicast (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables the user to decide about frame type * all frame * just broadcast * just multicast." ::= { maskingEntry 6 } maskingFrameTypeCondition OBJECT-TYPE SYNTAX INTEGER { false (1), true (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the logical condition of the mask pattern: true - Condition is valid if at the position specified by maskingFrameType the packet contains data that matches the content of maskingFrameType. fa lse - Condition is valid if at the position specified by maskingFrameType the packet contains data that does not match the content of maskingFrameType." ::= { maskingEntry 7 } maskingSourceAddress OBJECT-TYPE SYNTAX GenAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The source address is according to the maskingMacOrNet and maskingProtocolType variables. In case of 'MAC' enter 6 bytes (48 bit) of source address. In case of 'NET' if the maskingProtocolType is IP, this is the IP address if the maskingProtocolType is IPX, this is the IPX address (nnnnmmmmmmss) nnnn - IPX net address mmmmmm - Node address (Mac) ss - IPX socket In case of 'Apple' nn - net address (4 nibbles) ss - socket (4 nibbles)." ::= { maskingEntry 8 } maskingSourceActiveBits OBJECT-TYPE SYNTAX GenAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the positions of the wild card characters (*) in the maskingSourceAddress field. Only the 1's bit will be taken in considerations." ::= { maskingEntry 9 } maskingSourceMacOrNet OBJECT-TYPE SYNTAX INTEGER { macAddress (1), netAddress (2), ipRange (3), appleAddress(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The variable maskingSourceAddress and maskingSourceActiveBits will be treated as MAC, or NET address. - If maskingProtocolType = 'all', 'sna', 'netbios', dec or 'unknown', the maskingSourceMacOrNet can be macAddress only! - If maskingProtocolType = 'ip' the maskingSourceMacOrNet can be macAddress or netAddress or appleAddress. - If maskingProtocolType = 'ipx', the maskingSourceMacOrNet can be either macAddress or netAddress. - If maskingProtocolType = 'apple', the maskingSourceMacOrNet can be either macAddress or appleAddress." ::= { maskingEntry 10 } maskingSourceCondition OBJECT-TYPE SYNTAX INTEGER { false (1), true (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the logical condition of the mask pattern: true - Condition is valid if at the position specified by maskingSourceAddress (in conjunction with maskingSourceActiveBits) the packet contains data that matches the content of maskingSourceAddress. false - Condition is valid if at the position specified by maskingSourceAddress (in conjunction with maskingSourceActiveBits) the packet contains data that does not match the content of maskingSourceAddress." ::= { maskingEntry 11 } maskingDestAddress OBJECT-TYPE SYNTAX GenAddress MAX-ACCESS read-write STATUS current DESCRIPTION "If maskingFrameType = broadcast or multicast, this object is NOT APPLICABLE. If maskingFrameType = all or unknown, this object is applicable. The destination address is according to the maskingMacOrNet and maskingProtocolType variables. In case of 'MAC' enter 6 bytes (48 bit) of source address. In case of 'NET' if the maskingProtocolType is IP, this is the IP address if the maskingProtocolType is IPX, this is the IPX address (nnnnmmmmmmss) nnnn - IPX net address mmmmmm - Node address (Mac) ss - IPX socket. In case of 'Apple' nn - net address (4 nibbles) ss - socket (4 nibbles). The IPX socket entered here has priority over the value of maskingLowLevelProt, when it is ipxRip, ipxSap or ipxSpx, unless the entered IPX socket is don't care. " ::= { maskingEntry 12 } maskingDestActiveBits OBJECT-TYPE SYNTAX GenAddress MAX-ACCESS read-write STATUS current DESCRIPTION "If maskingFrameType = broadcast or multicast, this object is NOT APPLICABLE. If maskingFrameType = all or unknown, this object is applicable. Specifies the positions of the wild card characters (*) in the maskingDestAddress field. Only the 1's bit will be taken in considerations." ::= { maskingEntry 13 } maskingDestMacOrNet OBJECT-TYPE SYNTAX INTEGER { macAddress (1), netAddress (2), ipRange (3), appleAddress(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "If maskingFrameType = broadcast or multicast, this object is NOT APPLICABLE. If maskingFrameType = all or unknown, this object is applicable. - If maskingProtocolType = 'all', 'sna', 'netbios', dec or 'unknown', the maskingDestMacOrNet can be macAddress only! - If maskingProtocolType = 'ip' the maskingDestMacOrNet can be macAddress or netAddress or appleAddress. - If maskingProtocolType = 'ipx', the maskingDestMacOrNet can be either macAddress or netAddress. - If maskingProtocolType = 'apple', the maskingDestMacOrNet can be either macAddress or appleAddress. The variable maskingDestAddress and maskingDestActiveBits will be treated as MAC, or NET address. " ::= { maskingEntry 14 } maskingDestCondition OBJECT-TYPE SYNTAX INTEGER { false (1), true (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "If maskingFrameType = broadcast or multicast, this object is NOT APPLICABLE. If maskingFrameType = all or unknown, this object is applicable. Specifies the logical condition of the mask pattern: true - Condition is valid if at the position specified by maskingDestAddress (in conjunction with maskingDestActiveBits) the packet contains data that matches the content of maskingDestAddress. false - Condition is valid if at the position specified by maskingDestAddress (in conjunction with maskingDestActiveBits) the packet contains data that does not match the content of maskingDestAddress." ::= { maskingEntry 15 } maskingLowLevelProt OBJECT-TYPE SYNTAX INTEGER { unknown (1), -- don't care ipxRip (2), -- 0x51 ipxSap (3), -- 0x52 ipxSpx (4), -- 0x53 ipUdp (5), -- 0x54 ipTcp (6), -- 0x55 ipIcmp (7), -- 0x56 ipxNcp (8), -- 0x57 ipxWan (9), -- 0x58 ipxEco (10), -- 0x59 ipxErr (11), -- 0x5a ipxPep (12) -- 0x5b } MAX-ACCESS read-write STATUS current DESCRIPTION "This field is set in conjunction with the maskingProtocolType variable. This variable specifies the low level protocol. The IPX socket entered in maskingDestAddress has priority over the value of maskingLowLevelProt, when it is ipxRip, ipxSap or ipxSpx, unless the entered IPX socket is don't care." ::= { maskingEntry 16 } maskingLowLevelProtCondition OBJECT-TYPE SYNTAX INTEGER { false (1), true (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the logical condition of the mask pattern: true - Condition is valid if at the position specified by maskingLowLevelProt the packet contains data that matches the content of maskingLowLevelProt. false - Condition is valid if at the position specified by maskingLowLevelProt the packet contains data that does not match the content of maskingLowLevelProt." ::= { maskingEntry 17 } maskingHighLevelProt OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This field is set in connection to the maskingProtocolType variable. This variable specifies the high level protocols (application). As for today it supports just IP protocol stack. The object's value is a sum of the following instances values (selected by user): none (0), -- don't care ftp (1), ftpC (2), telnet (4), smtp (8), tftp (16), snmp (32), snmpTrap (64), ipRip (128), www (256), email (512), dns (1024), For Apple Protocol only: rtmp (2048), nbp (4096), atp (8192), aep (16384), zip (32768), adsp (65536), pap (131072), asp (262144) Example: if ftp(1), snmp(32) and snmpTrap(64) instances were selected, the value should be 97 (=1+32+64)." ::= { maskingEntry 18 } maskingHighLevelProtCondition OBJECT-TYPE SYNTAX INTEGER { false (1), true (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the logical condition of the mask pattern: true - Condition is valid if at the position specified by maskingHighLevelProt the packet contains data that matches the content of maskingHighLevelProt. false - Condition is valid if at the position specified by maskingHighLevelProt the packet contains data that does not match the content of maskingHighLevelProt." ::= { maskingEntry 19 } maskingPortNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The port number is the same as in high level protocol. It specifies the dest. port in IP case or the dest. socket in case of IPX & apple protocols. IP - This object is applicable only if none (0) value was selected in maskingHighLevelProt. IPX - This object is applicable only if the socket entered in maskingDestAddress is 'don't care'(00) AND maskingLowLevelProt is NOT ipxRip or ipxSap. Apple - This option is applicable only if the socket entered in maskingDestAddress is 'don't care'(00)." ::= { maskingEntry 20 } maskingPortNumCondition OBJECT-TYPE SYNTAX INTEGER { false (1), true (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the logical condition of the mask pattern: true - Condition is valid if at the position specified by maskingPortNum the packet contains data that matches the content of maskingPortNum. false - Condition is valid if at the position specified by maskingPortNum the packet contains data that does not match the content of maskingPortNum. This object is applicable only when maskingPortNum is applicable." ::= { maskingEntry 21 } maskingOperation OBJECT-TYPE SYNTAX INTEGER { block (1), forward (2), route (3), forward-route (4), high-priority (5), noOp (6), delete (7), smartMask (8) } MAX-ACCESS read-write STATUS current DESCRIPTION "The type of action to be taken if the frame meets the conditions of the mask. noOp = disabled (mask remains on list, but is not active) delete = mask is removed from the list. smartMask = the operation and destination of the mask will be determined by the objects of the Smart Table (old masking table: radBridgeMaskTable). If maskingType is codConnect, the 'block' value is NOT allowed. If maskingType is codDisconnect, the 'forward' value is NOT allowed." ::= { maskingEntry 22 } maskingSrcPortNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The source port number. For IP: No Condition. For IPX: This object is applicable only if the socket entered in maskingSourceAddress is don't care (00) and maskingLowLevelProt is NOT ipxRip or ipxSap. For Apple:This object is applicable only if the socket entered in maskingSourceAddress is don't care (00). " ::= { maskingEntry 23 } maskingSrcPortNumCondition OBJECT-TYPE SYNTAX INTEGER { false (1), true (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The same as 'maskingPortNumCondition'. Relates to source port." ::= { maskingEntry 24 } radBridgePerformance OBJECT IDENTIFIER ::= {genBridge 7 } -- The RAD Bridge current table contains statistics being -- collected for the current 15 minute interval. radBridgeCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF RadBridgeCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The RAD Bridge Current table." ::= { radBridgePerformance 1 } radBridgeCurrentEntry OBJECT-TYPE SYNTAX RadBridgeCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the RAD Bridge Current table." INDEX { radBridgeCurrentIndex } ::= { radBridgeCurrentTable 1 } RadBridgeCurrentEntry ::= SEQUENCE { radBridgeCurrentIndex Integer32, radBridgeCurrentIngressFilteringDiscardedFrames Gauge32, radBridgeCurrentFrameTypeDiscardedFrames Gauge32 } radBridgeCurrentIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Bridge interface. It may be ifIndex." ::= { radBridgeCurrentEntry 1 } radBridgeCurrentIngressFilteringDiscardedFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Discarded Frames upon Ingress Filtering, encountered by a Bridge interface in the current 15 minute interval." ::= { radBridgeCurrentEntry 2 } radBridgeCurrentFrameTypeDiscardedFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Discarded Frames upon Frame Type and Tagging Mismatch, encountered by a Bridge interface in the current 15 minute interval." ::= { radBridgeCurrentEntry 3 } --Interval Table -- The RAD Bridge Interval table contains statistics being -- collected by each Interface over the previous 24 -- hours of operation. The past 24 hours are broken into 96 -- completed 15 minute intervals. radBridgeIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF RadBridgeIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The RAD Bridge Interval table." ::= { radBridgePerformance 2 } radBridgeIntervalEntry OBJECT-TYPE SYNTAX RadBridgeIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the RAD Bridge Interval table." INDEX { radBridgeIntervalIndex, radBridgeIntervalNumber } ::= { radBridgeIntervalTable 1 } RadBridgeIntervalEntry ::= SEQUENCE { radBridgeIntervalIndex Integer32, radBridgeIntervalNumber Integer32, radBridgeIntervalIngressFilteringDiscardedFrames Gauge32, radBridgeIntervalFrameTypeDiscardedFrames Gauge32 } radBridgeIntervalIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the bridge interface. It may be ifIndex." ::= { radBridgeIntervalEntry 1 } radBridgeIntervalNumber OBJECT-TYPE SYNTAX Integer32 (1..96) MAX-ACCESS read-only STATUS current DESCRIPTION "A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals exist)." ::= { radBridgeIntervalEntry 2 } radBridgeIntervalIngressFilteringDiscardedFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Discarded Frames upon Ingress Filtering, encountered by a Bridge interface in one of the previous 96, individual 15 minute, intervals." ::= { radBridgeIntervalEntry 3 } radBridgeIntervalFrameTypeDiscardedFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Discarded Frames upon Frame Type and Tagging Mismatch, encountered by a Bridge interface in one of the previous 96, individual 15 minute, intervals." ::= { radBridgeIntervalEntry 4 } -- -- file :v:\doc\rdv\mib\Before~1\trim.txt -- --Title: TrimBridge MIB --Version: 3.0 --Last revision: 9.10.94 --By: Debby Koren & Orly Nicklass --File: trim.txt -- Objects in this section are arranged into groups: -- trimInterface - Interface table and RS232 interface parameters -- trimBackup - Backup feature, Dial-up parameters. -- trimTR - Token Ring interface management -- trimTrapInfo - parameters that provide information on traps sent --Comments: The Trimbridge-16 agent also supports the following Public MIBs: -- MIB-II (RFC1213) -- dot5 ( RFC1231-MIB, updated by RFC1239 ) except for the optional Timers-table -- bridge (RFC 1493) --Comments: The Trimbridge-10 agent also supports the following Public MIBs: -- MIB-II (RFC1213) -- bridge (RFC 1493) -- the trimInterface group defines the Trimbridge interface table and parameters for -- RS232 interface trim OBJECT IDENTIFIER ::= {radBridges 3 } trimInterface OBJECT IDENTIFIER ::= { trim 1 } trimIfTable OBJECT-TYPE SYNTAX SEQUENCE OF TrimIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "RAD-specific interface table. " ::= { trimInterface 1 } trimIfEntry OBJECT-TYPE SYNTAX TrimIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table trimIfTable." INDEX { trimIfIndex } ::= { trimIfTable 1 } TrimIfEntry ::= SEQUENCE { trimIfIndex Integer32, trimIfBoardNum Integer32, trimIfNetAddress IpAddress, trimIfStatus INTEGER, trimIfClockType INTEGER, trimIfBaudRate Integer32, trimIfCost Integer32, trimIfCompression INTEGER, trimIfCompressionStatus INTEGER, trimIfCompressionRate Integer32, trimIfLATCompression INTEGER, trimIfCompressionType INTEGER, trimIfFilterMode INTEGER, trimIfConType INTEGER, trimIfRemAddress DisplayString, trimIfLocSubAddress DisplayString, trimIfRemSubAddress DisplayString, trimIfCLIVerification INTEGER } trimIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Index to the Trimbridge Interface Table. The interface defined by a particular value of this index is the same interface as identified by the same value of ifIndex (MIB II)." ::= { trimIfEntry 1 } trimIfBoardNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved for possible future use. Not currently applicable to Trimbridge." ::= { trimIfEntry 2 } trimIfNetAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The IP address of the interface defined by the particular value of trimIfIndex." ::= { trimIfEntry 3 } trimIfStatus OBJECT-TYPE SYNTAX INTEGER { ok (1), okSingleBrg(2), okMultiBrg(3), connctFault(4), rxFault(5), txFault(6), channelLoopback(7), rxClockFault(8), t1Alarm(9) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current status of the interface. Some of these status values are not applicable to Trimbridge." ::= { trimIfEntry 4 } trimIfClockType OBJECT-TYPE SYNTAX INTEGER { external(1), internal(2), t1(3), g703(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "trimIfClockType defines the type of clock each interface uses: internal or external." ::= { trimIfEntry 5 } trimIfBaudRate OBJECT-TYPE -- Level II routing SYNTAX Integer32 -- word MAX-ACCESS read-write STATUS current DESCRIPTION " Defines the baud rate in use by the interface. The valid rates are determined by the type of the media for which this baud rate is defined." ::= { trimIfEntry 6 } trimIfCost OBJECT-TYPE -- Level II routing SYNTAX Integer32 -- word MAX-ACCESS read-write STATUS current DESCRIPTION "This object is inapplicable to Trimbridge." ::= { trimIfEntry 7 } trimIfCompression OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Defines whether data compression is enabled or disabled for the interface." ::= { trimIfEntry 8 } trimIfCompressionStatus OBJECT-TYPE SYNTAX INTEGER { not-inserted(1), active(2), not-active(3), disable(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Defines the status of the compression component: not-inserted - compression component is not in the device active - compression is enabled and operates correctly not-active - compression is enables but does not operate. The reason may be that there is no compression component on the device connected to this interface. disabled - compression was disabled by management, using variable trimCompression." ::= { trimIfEntry 9 } trimIfCompressionRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Percentage of compression. This variable applies only if trimCompressionStatus is active." ::= { trimIfEntry 10 } trimIfLATCompression OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable the LAT Compression." ::= { trimIfEntry 11 } trimIfCompressionType OBJECT-TYPE SYNTAX INTEGER { none(1), lowSpeed(2), highSpeed(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the type of compression option available in the device. `None(1) - indicates that there is no compression option in the device lowSpeed(2) - indicates a compression option which is operational up to line speed sof 64 kbps. highSpeed(3) - indicates a compression option which is operational up to line speeds of 2 Mbps." ::= { trimIfEntry 12 } trimIfFilterMode OBJECT-TYPE SYNTAX INTEGER { destinationOnly(1), sourceAndDestination(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter indicates the type of filtering in the device. " ::= { trimIfEntry 13 } trimIfConType OBJECT-TYPE SYNTAX INTEGER { unknown(1), none(2), x21Old(3), x21(4), v35Old(5), v35(6), rs530Old(7), rs530(8), rs232Old(9), rs232(10), spsV35(11), spsRS530(12), spsRS232(13), spsX21(14), isdn(15) } MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the connector type of an interface. " ::= { trimIfEntry 14 } trimIfRemAddress OBJECT-TYPE SYNTAX DisplayString (SIZE(1..17)) MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { trimIfEntry 15 } trimIfLocSubAddress OBJECT-TYPE SYNTAX DisplayString (SIZE(1..6)) MAX-ACCESS read-write STATUS current DESCRIPTION "Space is not valid. If the string includes a space, the whole entry is considered not valid." ::= { trimIfEntry 16 } trimIfRemSubAddress OBJECT-TYPE SYNTAX DisplayString (SIZE(1..6)) MAX-ACCESS read-write STATUS current DESCRIPTION "Space is not valid. If the string includes a space, the whole entry is considered not valid." ::= { trimIfEntry 17 } trimIfCLIVerification OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables/Disables verification of Control Line Identification (CLI)" ::= { trimIfEntry 18 } -- The variables in this group define the RS232 management interface trimRS232Conf OBJECT IDENTIFIER ::= { trimInterface 2 } trimBaudRate OBJECT-TYPE SYNTAX INTEGER { br300(1), br1200(2), br2400(5), br4800(7), br9600(9), br19200(10) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selects the baud rate used by the RS232 management interface. The default selection is 1200 bits/second." ::= { trimRS232Conf 1 } trimParity OBJECT-TYPE SYNTAX INTEGER { noParity(1), oddParity(2), evenParity(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Determines whether the parity bit will be used and determines its type." ::= { trimRS232Conf 2 } trimStopBit OBJECT-TYPE SYNTAX INTEGER { oneStopBit(1), twoStopBit(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selects the number of stop bits appended to the end of each data word." ::= { trimRS232Conf 3 } trimThresholdRep OBJECT IDENTIFIER ::= { trimInterface 3} trimIfThresholdRepTable OBJECT-TYPE SYNTAX SEQUENCE OF TrimIfThresholdRepEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " ....." ::= {trimThresholdRep 1} trimIfThresholdRepEntry OBJECT-TYPE SYNTAX TrimIfThresholdRepEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table trimIfThresholdRepTable." INDEX { trimIfThreRepId,trimIfThreRepCounterId } ::= { trimIfThresholdRepTable 1} TrimIfThresholdRepEntry ::= SEQUENCE { trimIfThreRepId Integer32, trimIfThreRepCounterId INTEGER, trimThresholdValue Integer32, trimIfThreRepSampleRate Integer32, trimIfThreRepTrapRate Integer32 } trimIfThreRepId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The Interface number serves as an index to the Threshold Reoprt Table." ::= { trimIfThresholdRepEntry 1 } trimIfThreRepCounterId OBJECT-TYPE SYNTAX INTEGER{ vot(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Counter ID serves as an index to the Threshold Reoprt Table, and identify the counter for which to pot the threshold." ::= { trimIfThresholdRepEntry 2 } trimThresholdValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The Threshold value , this is the maximum rate of counter increments before the element issue trap." ::= { trimIfThresholdRepEntry 3 } trimIfThreRepSampleRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The network object will sample the counter atthis interval. When this parameter is set to 0, the treshold comparison is disable." -- DEFVAL { 10 } ::= { trimIfThresholdRepEntry 4} trimIfThreRepTrapRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " The network object will issue a trap according to this interval. Note that the trape interval nust be equal or larger then trimIfThreRepSampleRate." -- DEFVAL { 30 } ::= { trimIfThresholdRepEntry 5} -- trimBackup group defines the parameters for the backup feature trimBackup OBJECT IDENTIFIER ::= { trim 2 } trimBackupState OBJECT-TYPE SYNTAX INTEGER { main(1), backup(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "If main - the bridge is connected via the main physical link. If backup - the automatic backup feature was enabled and the bridge is connected via the backup physical link." ::= { trimBackup 1 } trimDialUpStatus OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter controls the operation of dial-up backup function. If status is disable(2), dial-up backup will not be initiated when the main link fails or exceeds the specified error limit. If status is enable(1), the dial-up backup will be initiated if the main link fails or if the error rate on the main link exceeds the limit specified by variable trimDialUp ErrorThreshold." ::= { trimBackup 2 } trimBackLinkType OBJECT-TYPE SYNTAX INTEGER { dialUp(1), leased (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable specifies the type of the backup link. If the type is leased(2), Trimbridge will reroute traffic to the backup link, when main link fails. If the value is dialUp(1), then the backup dial-up procedure is initiated when the main link fails." ::= { trimBackup 3 } trimDialUpMode OBJECT-TYPE SYNTAX INTEGER { originate(1), answer(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "If the mode is originate(1), Trimbridge initiates the backup procedure when the main link fails. if the mode is answer(2), it expects that the bridge on the other end of the link will initiate the backup procedure. Note that only one bridge in a pair should be set to mode originate(1). " ::= { trimBackup 4 } trimDialUpErrorThreshold OBJECT-TYPE SYNTAX INTEGER { none(1), low(2), medium(3), high(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Error rate on main link at which Backup will be enabled. low - 1*10-5 medium - 5*10-4 high - 1*10-3 If none(1) is selected, then backup is not invoked when there are errors on the main link, but only when the main link is down." ::= { trimBackup 5 } trimDialUpRedialTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "If an attempt to dial up failed for the specified time, a new redial attempt will be initiated." ::= { trimBackup 6} trimDialUpRedialNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable specifies the number of times to initiate the dial-up procedure. If the number of redials is set to zero (0), then the number of redials will be unlimited. Any other value will cause the dial-up procedure to terminate after the specified number of re-dial attempts fail. Resetting this variable to any value will re-initiate the dial-up procedure." ::= { trimBackup 7 } trimBackUpConnectDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The connect delay defines the minimum time period that the link must be disconnected." ::= { trimBackup 8 } trimBackUpDisConnectDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The disconnect delay defines the delay between the last valid traffic trigger and link disconnection." ::= { trimBackup 9 } trimBackUpScheduleTable OBJECT-TYPE SYNTAX SEQUENCE OF TrimBackUpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a table that contains the reroute shedule for the backup link. The index is the day of the week, starting with 1 for Sunday, ending with 7 for Saturday." ::= { trimBackup 10 } trimBackUpEntry OBJECT-TYPE SYNTAX TrimBackUpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table trimBackUpScheduleTable." INDEX { trimBackUpDay } ::= { trimBackUpScheduleTable 1 } TrimBackUpEntry ::= SEQUENCE { trimBackUpDay Integer32, trimBackUpFromTo DisplayString } trimBackUpDay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The day of the week for which the entry applies. The days are numbered from 1 to 7, representing Monday through Sunday." ::= { trimBackUpEntry 1 } trimBackUpFromTo OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This is the time during which backup should be disabled, expressed as xx:xx-yy:yy, where x's reflect the time from and y's reflect the time to. The first two digits, in x and in y, are the hour and the second two digits are the minutes. The pairs of digits are separated by a colon, and the x is separated from the y by a dash." ::= { trimBackUpEntry 2 } trimBackUpDelayAfterFailure OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This entry defines the delay between the last @@@@" ::= { trimBackup 11 } -- The trimTR group defines parameters for Token Ring interface management, in addition to parameters -- defined in the Public Token Ring MIB (RFC 1231). trimTR OBJECT IDENTIFIER ::= { trim 3 } trimTRIfTable OBJECT-TYPE SYNTAX SEQUENCE OF TrimTRIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table defines configuration parameters for Token Ring interfaces in the Trimbridge-16." ::= { trimTR 1 } trimTRIfEntry OBJECT-TYPE SYNTAX TrimTRIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table trimTRIfTable." INDEX { trimTRIfIndex } ::= { trimTRIfTable 1 } TrimTRIfEntry ::= SEQUENCE { trimTRIfIndex Integer32, trimTREarlyTokenRelease INTEGER, trimTRLocalAdminAddress MacAddress, trimTRLocalAdminAddressStatus INTEGER } trimTRIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Index to the Token Ring Interface Table. The interface defined by a particular value of this index is the same interface as identified by the same value of ifIndex (MIBII)." ::= { trimTRIfEntry 1 } trimTREarlyTokenRelease OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter controls the early token release. This paramenter is applicable only to 16 Mbps rings." ::= { trimTRIfEntry 2 } trimTRLocalAdminAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "A locally administered MAC Address of this interface." ::= { trimTRIfEntry 3 } trimTRLocalAdminAddressStatus OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter controls whether the bridge uses the locally administered MAC Address defined for this interface, when enable(1), or not , when disable(2)." ::= { trimTRIfEntry 4 } -- The trimTrapInfo group provides information on traps sent from Trimbridge trimTrapInfo OBJECT IDENTIFIER ::= {trim 4} trimErrorDesc OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A textual description of the enterprise-specific trap sent to the Network Management Station by Trimbridge." ::= { trimTrapInfo 1 } trimErrorSeverity OBJECT-TYPE SYNTAX INTEGER { information(1), warning(2), error(3), fatal(4)} MAX-ACCESS read-only STATUS current DESCRIPTION "The severity type of the enterprise-specific trap sent to the Network Management Station by Trimbridge." ::= { trimTrapInfo 2 } -- -- file :v:\doc\rdv\mib\ver485\lanrger4.txt -- --Version: 1.0 --Date: 16.10.94 --By: Debby Koren & Orly Nicklass --File: v:\doc\rdv\mib\ver485\Lanrger4.txt -- --Last Update: Smadar Tauber 07-July-2002 -- Comments: The LANRANger also supports the following Public MIBs: -- - MIB-II ( RFC1213 ) -- - Token Ring MIB (RFC 1231) or Ethernet MIB (RFC 1398), according to the LAN -- interface -- - RS-232 MIB (RFC 1317) lanranger OBJECT IDENTIFIER ::= {radBridges 2 } -- Objects in this MIB are arranged into groups: -- lanrangerConfig - LANRANger-specific configurable parameters -- lanrangerInterface - LANRANger-specific interface table -- lanrangerStation - Tables containing the list of remote workstations and related information -- and static entries -- At the end of the MIB there is a definition of all LANRANger-specific traps. -- the lanrangerConfig group defines configurable parameters that are specific to the LANRANger -- product line lanrangerConfig OBJECT IDENTIFIER ::= { lanranger 1 } lanrangerLoc OBJECT-TYPE SYNTAX INTEGER { main(1), remote(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "lanrangerLoc is set to main if the LANRANger is located on the main LAN and it is set to remote if it is located on a LAN at a remote site." ::= { lanrangerConfig 1 } lanrangerBurnAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This is the burned-in MacAddress on the LANRANger." ::= { lanrangerConfig 2 } lanrangerLocAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "This is a locally administered address. If a zero value appears, the network administrator did not set a locally administered address." ::= { lanrangerConfig 3 } lanrangerActiveAddress OBJECT-TYPE SYNTAX INTEGER {burnedIn(1), locallyAdministered(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The MAC address that is in use on the LANRANger. The address selected will appear in ifPhysAddress." ::= { lanrangerConfig 4 } lanrangerLearningStationTopology OBJECT-TYPE SYNTAX INTEGER { dynamic (1), permanent (2), permanentAndDynamic (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The Learning station topology defines for the LANRANger which type of station will be inserted in the station list. The default value is permanentAndDynamic(3). dynamic(1) - Learning lan station only. permanent(2) - permanentAndDynamic(3)- Setting this parameter will reset the LANRANger . ----- " ::= { lanrangerConfig 5 } lanrangerIpRouterInfo OBJECT IDENTIFIER ::= { lanrangerConfig 6 } lanrangerIpDefaultLink OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The default selected link, having the numbering system of ifIndex. The valid values range is: 1..ifIndex. The value must remain constant at least from one re-initialization of the network management agent to the next. notSupported = 255 " ::= { lanrangerIpRouterInfo 1 } lanrangerIpFastReTxLevel OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " The maximum buffer depth (queue length) for which lanranger will accept retransmission (for each station; the level is the same for all the stations). The valid values range is: 1..255 . " ::= { lanrangerIpRouterInfo 2 } lanrangerIpAgingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Ip aging time for a station - in min. " ::= { lanrangerIpRouterInfo 3 } --BOOT-P parameters; are relevant only for routers lanrangerIpBootP OBJECT IDENTIFIER ::= { lanrangerIpRouterInfo 4 } lanrangerBootPAction OBJECT-TYPE SYNTAX INTEGER { disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Activating (disable/enable) the BootP operation." ::= { lanrangerIpBootP 1 } lanrangerBootPAvailableEntries OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of available entries in the BootP table." ::= { lanrangerIpBootP 2 } lanrangerBootPCurrentEntries OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current number of BootP entries in the BootP table." ::= { lanrangerIpBootP 3 } lanrangerBootPTable OBJECT-TYPE SYNTAX SEQUENCE OF LanrangerBootPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of BootP entries. The number of entries is up to BootP current entries, according to the LANRANger model." ::= { lanrangerIpBootP 4 } lanrangerBootPEntry OBJECT-TYPE SYNTAX LanrangerBootPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "BootP parameters per entry of the BootP table." INDEX { lanrangerBootPIpAddress } ::= { lanrangerBootPTable 1 } LanrangerBootPEntry ::= SEQUENCE { lanrangerBootPIpAddress IpAddress, lanrangerBootPIfIndex INTEGER, lanrangerBootPOperation INTEGER } lanrangerBootPIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "BootP Ip Address." ::= { lanrangerBootPEntry 1 } lanrangerBootPIfIndex OBJECT-TYPE SYNTAX INTEGER {notAllocated (255)} MAX-ACCESS read-write STATUS current DESCRIPTION "The number is the same as the ifIndex of the link." ::= { lanrangerBootPEntry 2 } lanrangerBootPOperation OBJECT-TYPE SYNTAX INTEGER { active (1), delete (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the status of this entry. active(1) - this entry is currently in use and will remain so even after the next reset of the LANRANger. delete(2) - writing this value to the object, removes the corresponding entry from the table. " ::= { lanrangerBootPEntry 3 } lanrangerSpoofingInfo OBJECT IDENTIFIER ::= { lanrangerConfig 7 } lanrangerSpoofingAction OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Spoofing action is applied by bit code: enable : bit 0 set (disable: bit 0 is 0) keepAlive : bit 1 ... : bit 2 and so on. For the above example, to set spoofing to keepAlive action, the object's value will be 3 = [ 2**0 + 2**1 ] Only the Remote LANRANger will accept this object ! ------- " ::= { lanrangerSpoofingInfo 1 } lanrangerSpoofingAgingStation OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Aging time of stations list, in min. The agent 'translates' the time entered in minutes, to 10 min. resolution, as follows: 1..10 min - 10 min 11..20 min - 20 min and so on... 0 is not a valid value. Only the Remote LANRANger will accept this object ! ---------------- " ::= { lanrangerSpoofingInfo 2 } -- The variables in the lanrangerInterface group define LANRANger-specific and other -- link parameters and information lanrangerInterface OBJECT IDENTIFIER ::= { lanranger 2 } lanrangerLinkTable OBJECT-TYPE SYNTAX SEQUENCE OF LanrangerLinkEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of link entries. The number of entries is up to 8, according to the LANRANger model." ::= { lanrangerInterface 1 } lanrangerLinkEntry OBJECT-TYPE SYNTAX LanrangerLinkEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "LANRANger-specific parameter values for a link." INDEX {lanrangerLinkIndex } ::= { lanrangerLinkTable 1 } LanrangerLinkEntry ::= SEQUENCE { lanrangerLinkIndex Integer32, lanrangerLinkType INTEGER , lanrangerLinkState INTEGER, lanrangerLinkDTRMode INTEGER, lanrangerLinkStatus INTEGER, lanrangerLinkConnectionStatus INTEGER, lanrangerLinkNumOfLogLinks Integer32, lanrangerLinkReset INTEGER, lanrangerLinkRxMaskedFrames Counter32, lanrangerLinkLayer2Type INTEGER, lanrangerLinkLayer3Type INTEGER, lanrangerBackupLink Integer32, wrWanThrottle Integer32 } lanrangerLinkIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value for each link, equal to the value of ifIndex. The value for each link must remain constant at least from one re-initialization of the network management agent to the next." ::= { lanrangerLinkEntry 1 } lanrangerLinkType OBJECT-TYPE SYNTAX INTEGER { synchronous (1), asynchronous (2), x25FRconfig (3), x25FRchannel (4), isdn (5), frameRelay (6), pcmcia (7), dm2wire (8), notExist (254), unknown (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "The link type ." ::= { lanrangerLinkEntry 2 } lanrangerLinkState OBJECT-TYPE SYNTAX INTEGER { disable(2), enable (3), backup (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The link is disabled, enabled or backup." ::= { lanrangerLinkEntry 3 } lanrangerLinkDTRMode OBJECT-TYPE SYNTAX INTEGER { off(2), on(3), unknown(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "The link DTR mode." ::= { lanrangerLinkEntry 4 } lanrangerLinkStatus OBJECT-TYPE SYNTAX INTEGER { ok (1), fail (2), rxNoClock (3), txProblem (4), noCarrierD (5), unknown (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "The link physical status ." ::= { lanrangerLinkEntry 5 } lanrangerLinkConnectionStatus OBJECT-TYPE SYNTAX INTEGER { fail (1), disconnect(2), connect (3), wait (4), down (5), trying (6), testing (7), unknown (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "The link connection status." ::= { lanrangerLinkEntry 6 } lanrangerLinkNumOfLogLinks OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of logical links on this physical link. 0 = noLogicalLink " ::= { lanrangerLinkEntry 7 } lanrangerLinkReset OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to ON will reset the link . Upon completion the value will be set to OFF" ::= { lanrangerLinkEntry 8 } lanrangerLinkRxMaskedFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of masked frames received on this physical link." ::= { lanrangerLinkEntry 9 } lanrangerLinkLayer2Type OBJECT-TYPE SYNTAX INTEGER { unknown (1), bridge (2), ipRouter (3), ipxRouter (4), ipAndIpxRouter (5), bRouter (6), ipBrouter (7), ipxBrouter (8), ipAndIpxBrouter (9), bridgeAndStp (10) } MAX-ACCESS read-write STATUS current DESCRIPTION "The link layer 2 type indicates whether the link is Bridge or Router and specifies the Router's type." ::= { lanrangerLinkEntry 10 } lanrangerLinkLayer3Type OBJECT-TYPE SYNTAX INTEGER { unknown (1), proprietary (2), terminalServer (3), slip (30), cSlip (31), ppp (40), rfc1490 (41), hdlcFraming (42), mlPpp (43) } MAX-ACCESS read-write STATUS current DESCRIPTION "The link layer 3 type indicates the protocol type." ::= { lanrangerLinkEntry 11 } lanrangerBackupLink OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The backup link interface index located in the two LSB bytes. If the link is FR type, the two MSB will contain a DLCi number. For other link types the two MSB will equal to 0." ::= { lanrangerLinkEntry 12 } wrWanThrottle OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Throttle controls the baud rate of the WAN. For example if we have a WAN rate of 2M but we want only 1/2 M as the baud rate we set the Wan Throttle to 512k. These are the values: Full (2), 1M (3), 512k (4), 128k (5), 64k (6) Full throttle option (2) means the LAN rate." ::= { lanrangerLinkEntry 13 } --Link Connections lanrangerLinkConnection OBJECT IDENTIFIER ::= { lanrangerInterface 2 } lanrangerConnMaxEntries OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of entries in the Connection table." ::= { lanrangerLinkConnection 1 } lanrangerConnCurrentEntries OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current number of entries in the Connection table." ::= { lanrangerLinkConnection 2 } lanrangerLinkConnTable OBJECT-TYPE SYNTAX SEQUENCE OF LanrangerLinkConnEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of Connection entries. The number of entries is up to Max entries, according to the LANRANger model." ::= { lanrangerLinkConnection 3 } lanrangerLinkConnEntry OBJECT-TYPE SYNTAX LanrangerLinkConnEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about LANRANger Connection." INDEX {lanrangerLinkConnPhysLink, lanrangerLinkConnAid, lanrangerLinkConnMacAddr } ::= { lanrangerLinkConnTable 1 } LanrangerLinkConnEntry ::= SEQUENCE { lanrangerLinkConnPhysLink Integer32 , lanrangerLinkConnAid Integer32, lanrangerLinkConnMacAddr MacAddress, lanrangerLinkConnStatus INTEGER, lanrangerLinkConnDeviceType INTEGER, lanrangerLinkConnDeviceName DisplayString, lanrangerLinkConnDeviceSWVer DisplayString, lanrangerLinkConnNumLanStation Integer32, lanrangerLinkSyncStatus INTEGER } lanrangerLinkConnPhysLink OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The lanrangerLinkIndex for the physical link with which this logical link is associated." ::= { lanrangerLinkConnEntry 1 } lanrangerLinkConnAid OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value for each logical link. The maximum number of logical links is 256, according to the LANRANger model. The value for each logical link must remain constant at least from one re-initialization of the network management agent to the next. This index is the SPS address of the logical link. noLogicLink = 65535" ::= { lanrangerLinkConnEntry 2 } lanrangerLinkConnMacAddr OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The MAC address of the device that the logical link is connected to on the remote LAN." ::= { lanrangerLinkConnEntry 3 } lanrangerLinkConnStatus OBJECT-TYPE SYNTAX INTEGER { unknown (1), -- for router link none (2), -- no connection fail (3), connect (4), wait (5), down (6) } MAX-ACCESS read-only STATUS current DESCRIPTION "The link connection status." ::= { lanrangerLinkConnEntry 4 } lanrangerLinkConnDeviceType OBJECT-TYPE SYNTAX INTEGER { tre1 (1), tre8 (2), tre1D (3), tre8D (4), tre8M (5), rrTre (6), rrTre1D (7), rrTre8D (8), iTre1 (9), iTre2 (10), mpTre8 (11), kTre8 (12), treRasA (13), treRasS (14), trePCAsync(15), trePCSync (16), mbe1 (17), mbe8 (18), mbe1D (19), mbe8D (20), ete8M (21), iEre1 (22), iEe2 (23), mpMbe8 (24), kMbe8 (25), mbePCAsync(26), mbePCSync (27), mbeRasA (28), mbeRasS (29), other(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of device that the logical link is connected to on the remote LAN." ::= { lanrangerLinkConnEntry 5 } lanrangerLinkConnDeviceName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The logical name of the device that the logical link is connected to on the remote LAN." ::= { lanrangerLinkConnEntry 6 } lanrangerLinkConnDeviceSWVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "SW Version of the device that the logical link is connected to, on the remote LAN." ::= { lanrangerLinkConnEntry 7 } lanrangerLinkConnNumLanStation OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of stations of the remote LAN." ::= { lanrangerLinkConnEntry 8 } lanrangerLinkSyncStatus OBJECT-TYPE SYNTAX INTEGER { synchronized (1), syncNotObtained (2), waitForSync (3), codDisconnected (4), lcp (5), ip (6), ipvj (7), ipx (8), ipIpx (9), ipvj-ipx (10), mlPpp (11), mlPpp-ip (12), mlPpp-ip-ipvj (13), mlPpp-ip-ipx (14), mlPpp-ipvj-ipx (15), mlPpp-ipx (16), frUp (17), frDown (18), dlciUp (19), dlciDown (20), extLoop (21), ipcp (22), lcpIpcp (23), redAlarm (24), yellowAlarm (26), localSyncLoss (27), remoteSyncLoss (28), networkLoop (29), networkLoopRedAlarm (30), networkLoopYelAlarm (31), networkLocSyncLoss (32), networkRemSyncLoss (33), fdlLoop (34), fdlLoopRedAlarm (35), fdlLoopYellowAlarm (36), fdlLoopLocSyncLoss (37), fdlLoopRemSyncLoss (38), loopback (39), -- User Loop loopbackLocSyncLoss (40), loopbackRemSyncLoss (41) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Sync link status." ::= { lanrangerLinkConnEntry 9 } --Modem Table lanrangerModemTable OBJECT-TYPE SYNTAX SEQUENCE OF LanrangerModemEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of Modem entries. The number of entries is up to ifIndex." ::= { lanrangerInterface 3 } lanrangerModemEntry OBJECT-TYPE SYNTAX LanrangerModemEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "LANRANger-specific parameter values for a Modem." INDEX {lanrangerModemLinkIndex } ::= { lanrangerModemTable 1 } LanrangerModemEntry ::= SEQUENCE { lanrangerModemLinkIndex Integer32, lanrangerModemName DisplayString, lanrangerModemSettingString DisplayString, lanrangerModemAutobaudingSpeed INTEGER, lanrangerModemResetBeforeSetup INTEGER, lanrangerModemAnalyzeAnswers INTEGER, lanrangerModemSpeaker INTEGER, lanrangerModemDialingNumber DisplayString, lanrangerModemDialRetries Integer32, wrLocalDialBackNumber DisplayString, wrRingsBeforeAnswer Integer32 } lanrangerModemLinkIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "A list of asynchronous ports of the link, according to ifIndex. Synchronous ports will not appear in this table. Their port number will be skipped." ::= { lanrangerModemEntry 1 } lanrangerModemName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The Modem Name identifier for MBE/TRE. Up to 50 characters." ::= { lanrangerModemEntry 2 } lanrangerModemSettingString OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Modem setting String. Up to 80 characters." ::= { lanrangerModemEntry 3 } lanrangerModemAutobaudingSpeed OBJECT-TYPE SYNTAX INTEGER { disable(2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable or disable autobauding. When the Autobauding feature is enabled, the MBE/TRE automatically ranges over various Baud rates, starting with 115.2 Kbps, until the correct Baud rate of the modem is detected. " ::= { lanrangerModemEntry 4 } lanrangerModemResetBeforeSetup OBJECT-TYPE SYNTAX INTEGER { no (2), yes(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Reset the modem before setup is performed. It is recommended to reset the modem before modem setup session. " ::= { lanrangerModemEntry 5 } lanrangerModemAnalyzeAnswers OBJECT-TYPE SYNTAX INTEGER { disable(2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable this option if a modem using non-standard answering is used. When this mode is enabled, the MBE/TRE awaits modem answers 'CONNECT', 'CARRIER', or 'OK', after it transmits a modem command. Modem answers acknowledge, that a specific command has been executed. If this option is not enabled, the MBE/TRE waits for a modem answer for three seconds. If no answer has been received during this period, the MBE/TRE continues functioning as if the modem command was successfully executed. However, when dialing out, the MBE/TRE waits for one minute for connection." ::= { lanrangerModemEntry 6 } lanrangerModemSpeaker OBJECT-TYPE SYNTAX INTEGER { off (2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Toggle the Modem Speaker On or Off . " ::= { lanrangerModemEntry 7 } lanrangerModemDialingNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " Various command switches listed in Modem Dialing Number Menu allows selection of tone, pulse-dialing, or various wait states. P - Set Pulse dialing number . T - Set Tone dialing number . W - Wait for dialing tone before proceeding. ' - Pause for 2 seconds . @ - Wait for silence, one ring, followed by 5 sec. of silence . The Dialing Number will include both digits and letter/s of the command switches. The order and validity will be on user's responsibility. The DisplayString can have up to 40 characters." ::= { lanrangerModemEntry 8 } wrLocalDialBackNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " This is the number that the Remote Modem will use to call the local Modem at Dial Back. Various command switches listed in Modem Dialing Number Menu allows selection of tone, pulse-dialing, or various wait states. P - Set Pulse dialing number . T - Set Tone dialing number . W - Wait for dialing tone before proceeding. ' - Pause for 2 seconds . @ - Wait for silence, one ring, followed by 5 sec. of silence . The Dialing Number will include both digits and letter/s of the command switches. The order and validity will be on user's responsibility. The DisplayString can have up to 40 characters." ::= { lanrangerModemEntry 9 } wrRingsBeforeAnswer OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Determines which ring the modem will wait to answer the phone on." ::= { lanrangerModemEntry 10 } lanrangerModemDialRetries OBJECT-TYPE SYNTAX Integer32 (0..8) MAX-ACCESS read-write STATUS current DESCRIPTION "The number of dialing retries requested. Default = 0" ::= { lanrangerModemEntry 11} --Packet Switch Table lanrangerLinkPktSwTable OBJECT-TYPE SYNTAX SEQUENCE OF LanrangerLinkPktSwEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of X.25/FR modules entries. The number of entries is up to ifIndex." ::= { lanrangerInterface 4 } lanrangerLinkPktSwEntry OBJECT-TYPE SYNTAX LanrangerLinkPktSwEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "LANRANger-specific parameter values for X.25/FR modules." INDEX {lanrangerLinkPktSwIndex } ::= { lanrangerLinkPktSwTable 1 } LanrangerLinkPktSwEntry ::= SEQUENCE { lanrangerLinkPktSwIndex Integer32, lanrangerLinkPktSwType INTEGER, lanrangerLinkPktSwControlSignal INTEGER, lanrangerLinkPktSwSpeed Integer32, lanrangerLinkPktSwConfigParity INTEGER, lanrangerLinkPktSwConfigStopBit INTEGER, lanrangerLinkPktSwResetModule INTEGER } lanrangerLinkPktSwIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "A unique value for each X.25/FR of the link, according to numbering system of ifIndex. The maximum number of links is ifIndex. The value for each link must remain constant at least from one re-initialization of the network management agent to the next." ::= { lanrangerLinkPktSwEntry 1 } lanrangerLinkPktSwType OBJECT-TYPE SYNTAX INTEGER { x25FRChannel (1), x25FRConfig (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Packet Switch Type." ::= { lanrangerLinkPktSwEntry 2 } lanrangerLinkPktSwControlSignal OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Packet Switch control command. " ::= { lanrangerLinkPktSwEntry 3 } lanrangerLinkPktSwSpeed OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The Pkt Switch port's speed in bits per second. Range: 1200bps .. 1544000bps" ::= { lanrangerLinkPktSwEntry 4 } lanrangerLinkPktSwConfigParity OBJECT-TYPE SYNTAX INTEGER { none(1), odd(2), even(3), notApplicable(255)} MAX-ACCESS read-write STATUS current DESCRIPTION "The Pkt Switch Config port's character parity bit. Applicable only for x25FRConfigChannel. For x25FRChannel the value notApplicable applies." ::= { lanrangerLinkPktSwEntry 5 } lanrangerLinkPktSwConfigStopBit OBJECT-TYPE SYNTAX INTEGER { one(1), two(2), notApplicable(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "The Pkt Switch Config port's number of stop bits. Applicable only for x25FRConfigChannel. For x25FRChannel the value notApplicable applies." ::= { lanrangerLinkPktSwEntry 6 } lanrangerLinkPktSwResetModule OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Reset command to Pkt Switch module. Applicable only for x25FRChannel. The command will have no effect on x25FRConfigChannel." ::= { lanrangerLinkPktSwEntry 7 } -- lanrangerStation group contains a list of remote workstations and related information lanrangerStation OBJECT IDENTIFIER ::= {lanranger 3} lanrangerStationTable OBJECT-TYPE SYNTAX SEQUENCE OF LanrangerStationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains information about the stations on the remote LAN(s). A remote LANRANger contains a list of stations on its LAN, while a main LANRANger contains a list of stations at all the remote sites it is connected to." ::= { lanrangerStation 1 } lanrangerStationEntry OBJECT-TYPE SYNTAX LanrangerStationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about a specific station, that the LANRANger lists as being on a remote LAN." INDEX { lanrangerStationPhysLink, lanrangerStationLogLink, lanrangerStationAddress} ::= { lanrangerStationTable 1 } LanrangerStationEntry ::= SEQUENCE { lanrangerStationPhysLink Integer32, lanrangerStationLogLink Integer32, lanrangerStationAddress MacAddress, lanrangerStationStatus INTEGER, lanrangerStationSpoofingStatus INTEGER } lanrangerStationPhysLink OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of the physical link that is connected to the remote LAN on which the station with the associated instance of lanrangerStationAddress is located. The number is the same as the ifIndex of the link. The value will be zero on a remote LANRANger" ::= { lanrangerStationEntry 1 } lanrangerStationLogLink OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of the logical link that is connected to the remote LAN on which the station with the associated instance of lanrangerStationAddress is located. The value will be zero on a remote LANRANger. noLogicLink = 65535" ::= { lanrangerStationEntry 2 } lanrangerStationAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The unicast MAC address of a station that the LANRANger lists as being on a remote LAN." ::= { lanrangerStationEntry 3 } lanrangerStationStatus OBJECT-TYPE SYNTAX INTEGER { unknown(1), learned(2), self (3), static (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of this entry. The meanings of the values are: unknown(1) : learned(2) : the value of the corresponding instance of lanrangerStationAddress was learned and is being used. self(3) : the value of the corresponding instance of lanrangerStationAddress represents the LANRANger's address. static(4) : the value of the corresponding instance of lanrangerStationAddress is also the value of an existing instance of lanrangerStaticAddress." ::= { lanrangerStationEntry 4 } lanrangerStationSpoofingStatus OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The spoofing status of this entry." ::= { lanrangerStationEntry 5 } lanrangerLanMaxStations OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of stations in the station table." ::= { lanrangerStation 2 } lanrangerLanCurrentStations OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current number of stations in the station table." ::= { lanrangerStation 3 } --Permanent Stations lanrangerPermanentStation OBJECT IDENTIFIER ::= { lanrangerStation 4 } lanrangerPermanentMaxEntries OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of entries in the permanent stations table." ::= { lanrangerPermanentStation 1 } lanrangerPermanentCurrentEntries OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current number of entries in the permanent stations table." ::= { lanrangerPermanentStation 2 } lanrangerPermanentTable OBJECT-TYPE SYNTAX SEQUENCE OF LanrangerPermanentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table containing address information configured into the LANRANger by (local or network) management, specifying addresses on a remote LAN. This table objects can be set only on a Remote LANRANger." ::= { lanrangerPermanentStation 3 } lanrangerPermanentEntry OBJECT-TYPE SYNTAX LanrangerPermanentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Address information configured into the remote LANRANger by (local or network) management specifying addresses on a remote LAN." INDEX { lanrangerPermanentIfIndex, lanrangerPermanentLogLink, lanrangerPermanentAddress } ::= { lanrangerPermanentTable 1 } LanrangerPermanentEntry ::= SEQUENCE { lanrangerPermanentIfIndex Integer32, lanrangerPermanentLogLink Integer32, lanrangerPermanentAddress MacAddress, lanrangerPermanentOperation INTEGER } lanrangerPermanentIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of the physical link that is connected to the remote LAN, on which the station with the associated instance of lanrangerStationAddress is located. The number is the same as the ifIndex of the link. This data is interesting for main LANRANger only." ::= { lanrangerPermanentEntry 1 } lanrangerPermanentLogLink OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of the logical link that is connected to the remote LAN, on which the station with the associated instance of lanrangerPermanentAddress is located. The value will be noLogicLink on a remote LANRANger. This data is interesting for main LANRANger only. noLogicLink = 65535" ::= { lanrangerPermanentEntry 2 } lanrangerPermanentAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The MAC address entered by management to this entry. Only the remote LANRANger will accept Set for this object ! ---------------- " ::= { lanrangerPermanentEntry 3 } lanrangerPermanentOperation OBJECT-TYPE SYNTAX INTEGER { active (1), delete (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the status of this entry. active(1) - this entry is currently in use and will remain so even after the next reset of the LANRANger. delete(2) - writing this value to the object removes the corresponding entry. Only the remote LANRANger will accept Set for this object ! ---------------- " ::= { lanrangerPermanentEntry 4 } --IP Stations lanrangerIpStation OBJECT IDENTIFIER ::= { lanrangerStation 5 } lanrangerIpPermanentAvailableEntries OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The available number of entries in the IP permanent stations table." ::= { lanrangerIpStation 1 } lanrangerIpPermanentCurrentEntries OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current number of entries in the IP permanent station table." ::= { lanrangerIpStation 2 } -- The IP Permanent Stations table will be supported via the -- IP Forward table of RFC1354.MIB. lanrangerSpoofingStation OBJECT IDENTIFIER ::= {lanrangerStation 6} lanrangerSpoofingMaxEntries OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of entries in the Spoofing station table." ::= {lanrangerSpoofingStation 1} lanrangerSpoofingCurrentEntries OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current number of entries in the Spoofing station table." ::= {lanrangerSpoofingStation 2} lanrangerSpoofingTable OBJECT-TYPE SYNTAX SEQUENCE OF LanrangerSpoofingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of Spoofing entries. The number of entries is up to the current number of entries, according to the LANRANger model. Only the LOCAL LANRANger will show this table ! --------------- " ::= { lanrangerSpoofingStation 3 } lanrangerSpoofingEntry OBJECT-TYPE SYNTAX LanrangerSpoofingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Spoofing parameters per entry of the Spoofing table." INDEX {lanrangerSpoofingGroup, lanrangerSpoofingMacAddress } ::= { lanrangerSpoofingTable 1 } LanrangerSpoofingEntry ::= SEQUENCE { lanrangerSpoofingGroup Integer32, lanrangerSpoofingMacAddress MacAddress , lanrangerSpoofingAging Integer32, lanrangerSpoofingTimeLeft Integer32 } lanrangerSpoofingGroup OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The spoofing group. Only the LOCAL Lanranger will show this table ! " ::= { lanrangerSpoofingEntry 1 } lanrangerSpoofingMacAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION " MAC Address of the Remote Lanrangers. Only the LOCAL Lanranger will show this table ! " ::= { lanrangerSpoofingEntry 2 } lanrangerSpoofingAging OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " Aging time defined for a whole group, in minutes. Only the LOCAL Lanranger will show this table ! " ::= { lanrangerSpoofingEntry 3 } lanrangerSpoofingTimeLeft OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " Time until aging expires, per station, in minutes. Only the LOCAL Lanranger will show this table ! " ::= { lanrangerSpoofingEntry 4 } --PPP Table for the WebRanger wrPPPTable OBJECT-TYPE SYNTAX SEQUENCE OF WrPPPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains only parameters that do not exist in the PPP standard MIBS. The table contains a list of PPP entries. The number of entries is up to ifIndex." ::= { lanrangerInterface 5 } wrPPPEntry OBJECT-TYPE SYNTAX WrPPPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "LANRANger-specific parameter values for a PPP." INDEX {ifIndex } ::= { wrPPPTable 1 } WrPPPEntry ::= SEQUENCE { wrPPPCompressionHeaderField INTEGER, wrPPPCompressionProtocolFields INTEGER, wrPPPSTACCompressionType INTEGER, wrPPPAuthProtocol INTEGER, wrPPPSecurityType INTEGER, wrPPPUserName SnmpAdminString, wrPPPPassword SnmpAdminString, wrPPPLinkActiveTime Integer32 } wrPPPCompressionHeaderField OBJECT-TYPE SYNTAX INTEGER { compressionOff (2), compressionOn (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This configuration option provides a method to negotiate the compression of the Data Link Layer Address and Control fields. This configuration option is sent to inform the peer that the implementation can receive compressed Address and Control fields." ::= { wrPPPEntry 1 } wrPPPCompressionProtocolFields OBJECT-TYPE SYNTAX INTEGER { compressionOff (2), compressionOn (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This configuration option provides a method to negotiate the compression of the PPP Protocol field. This configuration option is sent to inform the peer that the implementation can receive such single octet Protocol fields. " ::= { wrPPPEntry 2 } wrPPPSTACCompressionType OBJECT-TYPE SYNTAX INTEGER { disable (1), noHistory (2), lCB (3), sequence (4), extended (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "The PPP compression control protocol provides a method to negotiate and utilize compression protocol over PPP encapsulated links. These are Different types of data compression algorithm for PPP encapsulated packets. " ::= { wrPPPEntry 3 } wrPPPAuthProtocol OBJECT-TYPE SYNTAX INTEGER { noneNone (1), chapNone (2), chapPap (3), chapChap (4), papNone (5), papPap (6) } MAX-ACCESS read-write STATUS current DESCRIPTION "The type of authentication protocol being used. The left parameter is the maximum authentication, the right parameter is minimum authentication." ::= { wrPPPEntry 4 } wrPPPSecurityType OBJECT-TYPE SYNTAX INTEGER { host (1), guest (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Type of unit." ::= { wrPPPEntry 5 } wrPPPUserName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..10)) MAX-ACCESS read-write STATUS current DESCRIPTION "PPP User name." ::= { wrPPPEntry 6 } wrPPPPassword OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..10)) MAX-ACCESS read-write STATUS current DESCRIPTION "PPP Password ." ::= { wrPPPEntry 7 } wrPPPLinkActiveTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "PPP link active time in seconds Values range: 2 - 900. Default value = 2 " ::= { wrPPPEntry 8 } -- Traps for use by the LANRANger --NOTIFICATIONS lanrangerEvents OBJECT-IDENTITY STATUS current DESCRIPTION "The events for the LANRANger." ::= { lanranger 0 } lanrangerLogLinkUp NOTIFICATION-TYPE OBJECTS { lanrangerLinkConnPhysLink, lanrangerLinkConnAid } STATUS current DESCRIPTION "The lanrangerLogLinkUp trap indicates that the indicated logical link is connected." ::= { lanrangerEvents 1 } lanrangerLogLinkDown NOTIFICATION-TYPE OBJECTS { lanrangerLinkConnPhysLink, lanrangerLinkConnAid } STATUS current DESCRIPTION "The lanrangerLogLinkDown trap indicates that the indicated logical link is disconnected." ::= { lanrangerEvents 2 } lanrangerLanTableOverflow NOTIFICATION-TYPE STATUS current DESCRIPTION "The station table has the maximum number of addresses for the LANRANger." ::= { lanrangerEvents 3 } lanrangerStatusChanged NOTIFICATION-TYPE OBJECTS { agnLed } STATUS current DESCRIPTION "The trap indicates changes in the device status ." ::= { lanrangerEvents 4 } -- -- file :v:\doc\rdv\mib\Before~1\febftb.txt -- -- Title: FEB MIB -- Version: 1.0 -- Date: 29 August 94 -- By: Orly Nicklass --File: febftb.txt -- Comments: This MIB is for FEBs and FTBs. These bridges also support the following MIBs: -- - MIB-II ( RFC1213 ) -- - BRIDGE - MIB ( RFC1493) -- - FDDI MIB (RFC 1512) -- The FDDI bridges also support the RAD General Bridge Branch, 164.4.1 -- Objects in this MIB are arranged into groups: -- febFtbTranslation - Defines parameters for translation of Ethernet and Token-Ring to/from FDDI -- febFtbStatus -- At the end of the MIB there is a definition of all FDDI bridge-specific traps. febFtb OBJECT IDENTIFIER ::= { radBridges 4 } febFtbTranslation OBJECT IDENTIFIER ::= { febFtb 1 } febFtbStatus OBJECT IDENTIFIER ::= { febFtb 2 } febFtbTranslIfTable OBJECT-TYPE SYNTAX SEQUENCE OF FebFtbTranslIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The translation table defines which type of translation is required for each device interface. This is particularly important for WAN links, as the translating device does not have a knowledge of the target LAN type." ::= { febFtbTranslation 1 } febFtbTranslIfEntry OBJECT-TYPE SYNTAX FebFtbTranslIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry in the translation table." INDEX { febFtbTranslIfIndex} ::= { febFtbTranslIfTable 1 } FebFtbTranslIfEntry ::= SEQUENCE { febFtbTranslIfIndex Integer32, febFtbTunnelProtocol OCTET STRING, febFtbTranslIPXRawEthernet INTEGER } febFtbTranslIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Index to the Translation Table. The interface defined by a particular value of this index is the same interface as identified by the same value of ifIndex (MIBII)." ::= { febFtbTranslIfEntry 1 } febFtbTunnelProtocol OBJECT-TYPE SYNTAX OCTET STRING (SIZE (2)) MAX-ACCESS read-write STATUS current DESCRIPTION "IEEE 802.1h standard defines the tunneling for Appletalk I. This parameter enables the user to specify Ethertype of an additional protocol to tunnel (e.g. IPX). For IPX, Enter 8137 to translate Token Ring SNAP frames to Ethernet_SNAP frames (instead of Ethernet II). Valid range of values: 05DC to FFFF (hex) 0000 (hex) - disables this function. " ::= { febFtbTranslIfEntry 2 } febFtbTranslIPXRawEthernet OBJECT-TYPE SYNTAX INTEGER { ethernetRaw8023(1), ethernet8022(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable defines the translation mode for IPX frames in standrad Token Ring format. It is applicable to Ethernet interfaces (i.e. febFtbTranslSwitch variable has value Ethernet (2). ). ethernetRaw8023: translate to Raw Ethernet frames (default) ethernet8022: translate to Ethernet 802.2 frames." ::= { febFtbTranslIfEntry 3 } febFtbLanTable OBJECT-TYPE SYNTAX SEQUENCE OF FebFtbLanTabEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "." ::= { febFtbStatus 1 } febFtbLanTabEntry OBJECT-TYPE SYNTAX FebFtbLanTabEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry in the LanTab table." INDEX { febFtbLanTabIfIndex} ::= { febFtbLanTable 1 } FebFtbLanTabEntry ::= SEQUENCE { febFtbLanTabIfIndex Integer32, febFtbLanTabEntNumber Integer32 } febFtbLanTabIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This variable defines the related interface" ::= { febFtbLanTabEntry 1 } febFtbLanTabEntNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This variable defines the number of entries in the LAN table reletaed to the specific interface" ::= { febFtbLanTabEntry 2 } febFtbFaults OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This variable defines the current device faults. It is a 32 bits variable, where each bit represents a unique fault" ::= { febFtbStatus 2 } --NOTIFICATIONS febFtbEvents OBJECT-IDENTITY STATUS current DESCRIPTION "The events for FEBs and FTBs." ::= { febFtb 0 } lanTableOverflow NOTIFICATION-TYPE STATUS current DESCRIPTION "The station table has the maximum number of addresses for the device." ::= { febFtbEvents 1 } statusChanged NOTIFICATION-TYPE OBJECTS {agnLed, agnIndication } STATUS current DESCRIPTION "A change occured in agent status or leds." ::= { febFtbEvents 2 } portFddiStatusChanged NOTIFICATION-TYPE OBJECTS {fddimibPORTPCMState, agnLed } STATUS current DESCRIPTION "The Fddi port status changed. fddimibPORTPCMState value has become off, maint, active, connect, or exited one of these states." ::= { febFtbEvents 3 } -- -- file :v:\doc\rdv\mib\Before~1\mlb.txt -- -- Title: RAD MLB MIB -- -- -- Version: 1.0 -- Date: November, 20, 1994 -- By: Ricky Yaffe -- File: mlb.txt mlb OBJECT IDENTIFIER ::= { radBridges 5 } -- Objects in this MIB are arranged into groups: -- mlbConfig - MLB - specific configurable parameters -- mlbAddress - MLB - Table containing the list of ports address . -- At the end of the MIB there is a definition of all MLB - specific traps. mlbConfig OBJECT IDENTIFIER ::= { mlb 1 } mlbMibVersion OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "mlb private mib version ." ::= { mlbConfig 1 } mlbPanelMedia OBJECT-TYPE SYNTAX INTEGER { unknown(1), copper(2), fiberOptic(3), notSupported (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The panel media. It can be fiber optic connector or STP+UTP in case of copper" ::= { mlbConfig 2 } mlbRRFrontPanelPort OBJECT-TYPE SYNTAX INTEGER { unknown(1), secondary(2), main(3), notSupported (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Front panel port function : MainPort / Sec.Port (case of RADring card) ." ::= { mlbConfig 3 } mlbRRTermination OBJECT-TYPE SYNTAX INTEGER { unknown(1), on(2), off(3), notSupported (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Temination switch - Split back lan and Terminate it. (case of RADring card) ." ::= { mlbConfig 4 } mlbAddress OBJECT IDENTIFIER ::= {mlb 2} mlbAddressTable OBJECT-TYPE SYNTAX SEQUENCE OF MlbAddressEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains information about the MLB ports address ." ::= { mlbAddress 1 } mlbAddressEntry OBJECT-TYPE SYNTAX MlbAddressEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about a specific port that the MLB lists define." INDEX {mlbPortIndex } ::= { mlbAddressTable 1 } MlbAddressEntry ::= SEQUENCE { mlbPortIndex Integer32, mlbBurnAddress MacAddress, mlbLocAddress MacAddress, mlbActiveAddress INTEGER } mlbPortIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value for each port, equal to the value of ifIndex for the port. The maximum number of ports for mlb is 2 . " ::= { mlbAddressEntry 1 } mlbBurnAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This is the burned-in MacAddress on the LANRANger." ::= { mlbAddressEntry 2 } mlbLocAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "This is a locally administered address. If a zero value appears, the network administrator did not set a locally administered address." ::= { mlbAddressEntry 3 } mlbActiveAddress OBJECT-TYPE SYNTAX INTEGER {burnedIn(1), locallyAdministered(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The MAC address that is in use on the LANRANger. The address selected will appear in ifPhysAddress." ::= { mlbAddressEntry 4 } --NOTIFICATIONS mlbEvents OBJECT-IDENTITY STATUS current DESCRIPTION "The events for the MLB." ::= { mlb 0 } mlbLanTableOverflow NOTIFICATION-TYPE STATUS current DESCRIPTION "The station table has the maximum number of addresses for the LANRANger." ::= { mlbEvents 1 } mlbStatusChanged NOTIFICATION-TYPE OBJECTS { agnLed } STATUS current DESCRIPTION "The trap indicates changes in the device status ." ::= { mlbEvents 2 } -- -- file :v:\doc\rdv\mib\Before~1\cvt.txt -- --Version: 1.0 --Date: 16.10.94 --By: RADLINX & Orly Nicklass --File: cvt.txt -- genSnar OBJECT IDENTIFIER ::= { radConverters 1 } -- SNAR - SNA conversion software -- STC, FTC - Token to SDLC conversion devices -- SEC, FEC - Ether to SDLC conversion devices -- XTC - X.25/QLLC conversion device -- -- Definitions apply to all products, -- unless otherwise specified. -- The devices are generally referred -- as 'device'. -- Sap ::= OCTET STRING (SIZE (1)) SdlcAddr ::= OCTET STRING (SIZE (1)) -- OctetRange ::= Integer32 (1..255) --Active ::= INTEGER { inactive(1) , active(2) } --Side ::= INTEGER { sideA(1) , sideB(2) } --Enable ::= INTEGER { disable(1) , enable(2) } --** THE SNAR TREE **-- snarState OBJECT IDENTIFIER ::= { genSnar 1 } snarNva OBJECT IDENTIFIER ::= { genSnar 3 } snarSna OBJECT IDENTIFIER ::= { genSnar 5 } -- -- SNAR state group -- General state information -- snarStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), test (3) } MAX-ACCESS read-write STATUS current DESCRIPTION " The status of the whole SNAR process 1 -up 2 -down 3 -test (After setting one of the previous states, the status will be test until the changes will be done). " ::= { snarState 1 } snarBufferUsage OBJECT-TYPE SYNTAX Integer32 (0..100) MAX-ACCESS read-only STATUS current DESCRIPTION " The buffer usage of the SNAR (in percentage). " ::= { snarState 2 } snarMaxSnaSession OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " Max number of sessions supported in this SNAR implementation " ::= { snarState 3 } snarSaveChanges OBJECT-TYPE SYNTAX INTEGER{ noSave (1), save (2), saveAndReset (3), undoAllChanges (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "N/A to SNAR, only for devices. When changes are made to any configuration parameters (SNA, NVA or others) it should be stored in the device's NVRAM and then the device is restarted. Using this variable the manager can: 2 - Just save into NVRAM all configuration changes 3 - Save into NVRAM the configuration changes and restart the Device, to reflect the changes. 4 - Undo all changes since last reset or save, (without resetting the device). Load the original configuration from the NVRAM. " ::= { snarState 5 } -- -- snarNVA group -- -- Defines the NetView agent configuration and internal -- statistics, applicable to SNAR and all devices -- nvaAgentsNumber OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " The number of configured NetView agents " ::= { snarNva 2 } --********* nvaAgentTable OBJECT-TYPE SYNTAX SEQUENCE OF NvaAgentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { snarNva 3 } nvaAgentEntry OBJECT-TYPE SYNTAX NvaAgentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table nvaAgentTable." INDEX { nvaAgIndex } ::= { nvaAgentTable 1 } NvaAgentEntry ::= SEQUENCE { nvaAgIndex Integer32, nvaAgAdminStatus INTEGER, nvaAgOperState INTEGER, nvaAgFilter OCTET STRING, nvaAgAllowRunCmd INTEGER, --****CFG****** nvaAgAccessType INTEGER, nvaAgIfIndex Integer32, nvaAgXidBlockId OCTET STRING, nvaAgXidBlockNum OCTET STRING, nvaAgSSap Sap, nvaAgDSap Sap, nvaAgRemMacAddr MacAddress, nvaAgSdlcAddr SdlcAddr, nvaAgResourceName DisplayString } nvaAgIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Agent number . Range (1 - nvaAgentsNumber) " ::= { nvaAgentEntry 1 } nvaAgAdminStatus OBJECT-TYPE SYNTAX INTEGER { disable(1) , enable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " The admin. status of NV AGENT. Value of 'disable' will prevent the NetView agent from trying to connect to the NetView management system " ::= { nvaAgentEntry 3 } nvaAgOperState OBJECT-TYPE SYNTAX INTEGER { inactive(1) , active(2) } MAX-ACCESS read-only STATUS current DESCRIPTION " Current Operation state of the NetView agent. Active state means that the NetView agent is in session with the NetView management system " ::= { nvaAgentEntry 4 } nvaAgFilter OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Alert filter bit mask. Each bit corresponds to a specific alert sent by the NetView agent. " ::= { nvaAgentEntry 5 } nvaAgAllowRunCmd OBJECT-TYPE SYNTAX INTEGER { disable(1) , enable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Defines whether the NetView agent is allowed to handle operational commands, received by the RUNCMD facility " ::= { nvaAgentEntry 6 } nvaAgAccessType OBJECT-TYPE SYNTAX INTEGER{ llcCsmacd (1), llcTokenRing (3), sdlc (6), qllcX25 (10) } MAX-ACCESS read-write STATUS current DESCRIPTION " Defines the method in which the agent tries to connect to the NetView management system(the SNA host) " ::= { nvaAgentEntry 7 } nvaAgIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " The port number of the interface in which the NetView agent connects to the SNA host " ::= { nvaAgentEntry 8 } nvaAgXidBlockId OBJECT-TYPE SYNTAX OCTET STRING (SIZE (2)) MAX-ACCESS read-write STATUS current DESCRIPTION " The BLOCKID part of the XID information which the NetView agent should use to connect to the NetView management system (The SNA host) " ::= { nvaAgentEntry 9 } nvaAgXidBlockNum OBJECT-TYPE SYNTAX OCTET STRING (SIZE (3)) MAX-ACCESS read-write STATUS current DESCRIPTION " The BLOCKNUM part of the XID information which the NetView agent should use to connect to the NetView management system (The SNA host) " ::= { nvaAgentEntry 10 } nvaAgSSap OBJECT-TYPE SYNTAX Sap MAX-ACCESS read-write STATUS current DESCRIPTION " Local SAP, used for the NetView session - for LLC access type session only. " ::= { nvaAgentEntry 11 } nvaAgDSap OBJECT-TYPE SYNTAX Sap MAX-ACCESS read-write STATUS current DESCRIPTION " Remote(host) Sap used by the NetView agent for the SNA host connection - for LLC access session type only. " ::= { nvaAgentEntry 12 } nvaAgRemMacAddr OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION " Remote(host) MAC address used by the NetView agent for the SNA host connection - for LLC access session type only. " ::= { nvaAgentEntry 13 } nvaAgSdlcAddr OBJECT-TYPE SYNTAX SdlcAddr MAX-ACCESS read-write STATUS current DESCRIPTION " SDLC address used by the NetView agent for the SNA host connection - for SDLC access session type only. " ::= { nvaAgentEntry 14 } nvaAgResourceName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " A 4 character name that is appended to the resource name in the NetView alerts sent by the NetView agent " ::= { nvaAgentEntry 15 } nvaAgentStatTable OBJECT-TYPE SYNTAX SEQUENCE OF NvaAgentStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { snarNva 4 } nvaAgentStatEntry OBJECT-TYPE SYNTAX NvaAgentStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table nvaAgentStatTable." INDEX { nvaAgStatIndex } ::= { nvaAgentStatTable 1 } NvaAgentStatEntry ::= SEQUENCE { nvaAgStatIndex Integer32, --*****STATISTICS**** nvaAgStatTime TimeTicks, nvaAgActPu Counter32, nvaAgDactPu Counter32, nvaAgRpNmvt Counter32, nvaAgRnNmvt Counter32, nvaAgSpNmvt Counter32, nvaAgSAlerts Counter32, nvaAgRRunCmd Counter32, nvaAgSRunCmd Counter32, nvaAgSPdstat Counter32 } nvaAgStatIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Agent number . Range (1 - nvaAgentsNumber) " ::= { nvaAgentStatEntry 1 } nvaAgStatTime OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-write STATUS current DESCRIPTION " Time since last reset of the NV agent statistics. Setting to a value of 0 will clear all Agents' statistics. " ::= { nvaAgentStatEntry 2 } nvaAgActPu OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of session initiation (ACTPU) requests received from the SNA host " ::= { nvaAgentStatEntry 3 } nvaAgDactPu OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of session disconnection (DACTPU) requests received from the SNA host " ::= { nvaAgentStatEntry 4 } nvaAgRpNmvt OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of NMVTs received from the SNA host, and responded with a positive response. " ::= { nvaAgentStatEntry 5 } nvaAgRnNmvt OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of NMVTs received from the SNA host, and respond with a negative response. " ::= { nvaAgentStatEntry 6 } nvaAgSpNmvt OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of NMVTs (of any type) sent to the SNA host. " ::= { nvaAgentStatEntry 7 } nvaAgSAlerts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of alert NMVTs sent by the NetView agent. " ::= { nvaAgentStatEntry 9 } nvaAgRRunCmd OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of RUNCMD (execute-command NMVTs) received by the NetView agent. " ::= { nvaAgentStatEntry 10 } nvaAgSRunCmd OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of RUNCMD replies sent to the NetView host. " ::= { nvaAgentStatEntry 11 } nvaAgSPdstat OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of PDSTAT NMVTs sent by the NetView agent. " ::= { nvaAgentStatEntry 12 } -- -- snaSNA group -- -- Defines the sessions' parameters to be converted -- --********* snaSessTable OBJECT-TYPE SYNTAX SEQUENCE OF SnaSessEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Holding SNA session's parameters for each side of a specific session, indexed by session_id " ::= { snarSna 3 } snaSessEntry OBJECT-TYPE SYNTAX SnaSessEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table snaSessTable." INDEX { sessIfIndex, sessId, sessSide } ::= { snaSessTable 1 } SnaSessEntry ::= SEQUENCE { sessIfIndex Integer32, sessId Integer32, sessSide INTEGER, sessDev Integer32, sessAdminStatus INTEGER, sessOperState INTEGER, sessAccessType INTEGER, sessSXidBlockId OCTET STRING, sessSXidBlockNum OCTET STRING, --** LLC/SDLC ** sessSSap Sap, sessDSap Sap, sessRemMacAddr MacAddress, --** SDLC ** sessSdlcAddr SdlcAddr, sessGroupPoll SdlcAddr, sessRole INTEGER, --** LLC/IP ** sessIpEncapsulated INTEGER, sessDestIpAddr IpAddress, --** QLLC x25 ** sessRemX25Addr OCTET STRING } sessIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Interface used by this SNA session " ::= { snaSessEntry 1 } sessId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The unique identifier of the converted SNA session id " ::= { snaSessEntry 2 } sessSide OBJECT-TYPE SYNTAX INTEGER { sideA(1) , sideB(2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The SNA session side. Each session handled by SNAR/device, creates 2 SNA sessions, hereafter called 'side A' and 'side B' Configuration parameters, and Statistics are defined for each side separately. " ::= { snaSessEntry 3 } sessDev OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The device number, used in devices setup. N/A to SNAR. " ::= { snaSessEntry 4 } sessAdminStatus OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2), underCreation (3), stop (4), start (5), invalid (10) } MAX-ACCESS read-write STATUS current DESCRIPTION " Admin. status of this session, as requested by the manager. 10 - Session is invalid, and not handled by SNAR devices. 1 - Session is disabled. SNAR/Device will not try to start this session. 2- Session is enabled. SNAR/Device will try to start this session. 3- Under_creation - This session parameters are under creation, manipulated by a manager. 4 - stop: stop an enabled session immediately - no need to save change. 5 - start :start a stopped sessions immediately - no need to save change. " ::= { snaSessEntry 5 } sessOperState OBJECT-TYPE SYNTAX INTEGER { stopped (1), disabled (2), sdlcProb03 (3), llcProb04 (4), ifProb30 (30), ifProb80 (80), ifProb81 (81), ifProb87 (87), ifProb88 (88), ok (99) } MAX-ACCESS read-only STATUS current DESCRIPTION " Current operating state. See Manual reference for more information. " ::= { snaSessEntry 6 } sessAccessType OBJECT-TYPE SYNTAX INTEGER{ llcCsmacd (1), llcTokenRing (3), sdlc (6), qllcX25 (10) } MAX-ACCESS read-write STATUS current DESCRIPTION "The access type used by this side of the converted session. " ::= { snaSessEntry 7 } sessSXidBlockId OBJECT-TYPE SYNTAX OCTET STRING (SIZE (2)) MAX-ACCESS read-write STATUS current DESCRIPTION "The BLOCKID part of the XID information sent by this side for the SNA session initiation " ::= { snaSessEntry 8 } sessSXidBlockNum OBJECT-TYPE SYNTAX OCTET STRING (SIZE (3)) MAX-ACCESS read-write STATUS current DESCRIPTION "The BLOCKNUM part of the XID information sent by this side for the SNA session initiation " ::= { snaSessEntry 9 } sessSSap OBJECT-TYPE SYNTAX Sap MAX-ACCESS read-write STATUS current DESCRIPTION "The Local SAP used by SNAR for this session's side (LLC sessions only) " ::= { snaSessEntry 10 } sessDSap OBJECT-TYPE SYNTAX Sap MAX-ACCESS read-write STATUS current DESCRIPTION "The remote SAP used by SNAR for this session's side (LLC sessions only) " ::= { snaSessEntry 11 } sessRemMacAddr OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The remote MAC address used by this session's side (LLC sessions only) " ::= { snaSessEntry 12 } sessSdlcAddr OBJECT-TYPE SYNTAX SdlcAddr MAX-ACCESS read-write STATUS current DESCRIPTION "The SDLC address used by this session's side (SDLC sessions only, both primary and secondary) " ::= { snaSessEntry 13 } sessGroupPoll OBJECT-TYPE SYNTAX SdlcAddr MAX-ACCESS read-write STATUS current DESCRIPTION "The address of the group poll in which this session's side participates (SLDC secondary only). A value of 0 indicates that it doesn't participate in any group. Only one group is supported for each SDLC line (same port) " ::= { snaSessEntry 14 } sessRole OBJECT-TYPE SYNTAX INTEGER{ primary (1), secondary (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The type of SDLC session for this side. " ::= { snaSessEntry 15 } sessIpEncapsulated OBJECT-TYPE SYNTAX INTEGER { disable(1) , enable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specified whether this session data is encapsulated within UDP/IP " ::= { snaSessEntry 16 } sessDestIpAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The destination IP address (IP encapsulated sessions only). " ::= { snaSessEntry 17 } sessRemX25Addr OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "The remote X25 address (QLLC only) . " ::= { snaSessEntry 18 } --********* snaSessTuneTable OBJECT-TYPE SYNTAX SEQUENCE OF SnaSessTuneEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Holding SNA session parameters for each side of a specific session, indexed by session_id " ::= { snarSna 4 } snaSessTuneEntry OBJECT-TYPE SYNTAX SnaSessTuneEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table snaSessTuneTable." INDEX { sessTuneIfIndex, sessTuneId, sessTuneSide} ::= { snaSessTuneTable 1 } SnaSessTuneEntry ::= SEQUENCE { sessTuneIfIndex Integer32, sessTuneId Integer32, sessTuneSide INTEGER, --** TUNNING ** sessBufferSize Integer32, sessSegmentation INTEGER, sessFirstSide INTEGER, sessWindow Integer32, sessDuplex INTEGER, sessRXidBlockId OCTET STRING, sessRXidBlockNum OCTET STRING, sessCheckXid INTEGER, sessT1 Integer32, sessTi Integer32, sessT2 Integer32, sessN2 Integer32, sessUdpPort Integer32 } sessTuneIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The SNA session side. " ::= { snaSessTuneEntry 1 } sessTuneId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The unique identifier of the converted SNA session. " ::= { snaSessTuneEntry 2 } sessTuneSide OBJECT-TYPE SYNTAX INTEGER { sideA(1) , sideB(2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The SNA session's side. " ::= { snaSessTuneEntry 3 } sessBufferSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " The max. buffer size of remote device (All sessions). " ::= { snaSessTuneEntry 4 } sessSegmentation OBJECT-TYPE SYNTAX INTEGER { disable(1) , enable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " Specifies whether the SNAR should perform segmentation when incoming frame on one side is longer then the sessSideBufferSize of the other size 1 - disable - don't perform segmentation 2 - enable - perform segmentation " ::= { snaSessTuneEntry 5 } sessFirstSide OBJECT-TYPE SYNTAX INTEGER { sideA(1) , sideB(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies which side of the two SNA sides (side_a or side_b) should be started first (SNAR only, N/A to devices) " ::= { snaSessTuneEntry 6 } sessWindow OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " The max window size (1 .. 127) for this session's side. " ::= { snaSessTuneEntry 7 } sessDuplex OBJECT-TYPE SYNTAX INTEGER{ half (1), full (2) } MAX-ACCESS read-write STATUS current DESCRIPTION " Specifies the type of SDLC device on the other end of the SDLC line. FULL- means a device capable of transmit and receive data simultaneously. " ::= { snaSessTuneEntry 8 } sessRXidBlockId OBJECT-TYPE SYNTAX OCTET STRING (SIZE (2)) MAX-ACCESS read-write STATUS current DESCRIPTION "The BLOCKID part of the XID information expected to be received on this side of the SNA session " ::= { snaSessTuneEntry 9 } sessRXidBlockNum OBJECT-TYPE SYNTAX OCTET STRING (SIZE (3)) MAX-ACCESS read-write STATUS current DESCRIPTION "The BLOCKNUM part of the XID information expected to be received on this side of the SNA session " ::= { snaSessTuneEntry 10 } sessCheckXid OBJECT-TYPE SYNTAX INTEGER { disable(1) , enable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specified whether the received XID information should be checked and compared to the value of sessRXid: 1 - disable: don't check 2 - enable : check " ::= { snaSessTuneEntry 11 } sessT1 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " The T1 timer (in 100 msec) for this session's side. " ::= { snaSessTuneEntry 12 } sessTi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " The Ti timer (in sec) for this session " ::= { snaSessTuneEntry 13 } sessT2 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " The T2 timer (in 100 msec) for this session " ::= { snaSessTuneEntry 14 } sessN2 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " The N2 value for this session's side " ::= { snaSessTuneEntry 15 } sessUdpPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " The UDP port used by SNAR (IP encapsulated sessions only) " ::= { snaSessTuneEntry 16 } --********* snaSessStatTable OBJECT-TYPE SYNTAX SEQUENCE OF SnaSessStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Holding SNA session parameters for each side of a specific session, indexed by session_id " ::= { snarSna 5 } snaSessStatEntry OBJECT-TYPE SYNTAX SnaSessStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table snaSessStatTable." INDEX { sessStatIfIndex, sessStatId, sessStatSide } ::= { snaSessStatTable 1 } SnaSessStatEntry ::= SEQUENCE { sessStatIfIndex Integer32, sessStatId Integer32, sessStatSide INTEGER, --** STATISTICS ** sessStatTime TimeTicks, sessSPius Counter32, sessSBytes Counter32, sessRPius Counter32, sessRBytes Counter32, sessSessFailure Counter32, sessXidDenieds Counter32 } sessStatIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { snaSessStatEntry 1 } sessStatId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The unique identifier of the converted SNA session. " ::= { snaSessStatEntry 2 } sessStatSide OBJECT-TYPE SYNTAX INTEGER { sideA(1) , sideB(2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The SNA session's side. " ::= { snaSessStatEntry 3 } sessStatTime OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-write STATUS current DESCRIPTION " Time since last reset of this session statistics. Setting to a value of 0 will clear all session statistics. " ::= { snaSessStatEntry 4 } sessSPius OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " The number of PIUs sent by this session's side " ::= { snaSessStatEntry 5 } sessSBytes OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " The number of bytes sent by this session's side. " ::= { snaSessStatEntry 6 } sessRPius OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " The number of PIUs received by this session " ::= { snaSessStatEntry 7 } sessRBytes OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " The number of bytes received by this session's side. " ::= { snaSessStatEntry 8 } sessSessFailure OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " The number of session failures occurs to this session's side. " ::= { snaSessStatEntry 9 } sessXidDenieds OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " The number of XID denied by this session's side " ::= { snaSessStatEntry 10 } snaSessQllcTable OBJECT-TYPE SYNTAX SEQUENCE OF SnaSessQllcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Holding SNA session parameters for each side of a specific session, indexed by session_id " ::= { snarSna 7 } snaSessQllcEntry OBJECT-TYPE SYNTAX SnaSessQllcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table snaSessQllcTable." INDEX { sessQllcIfIndex, sessQllcId, sessQllcSide } ::= { snaSessQllcTable 1 } SnaSessQllcEntry ::= SEQUENCE { sessQllcIfIndex Integer32, sessQllcId Integer32, sessQllcSide INTEGER, --***QLLC PARAM sessInCalls INTEGER, sessOutCalls INTEGER, sessPVC INTEGER, sessCallReqData OCTET STRING, sessConnReqFacility OCTET STRING, sessGroupId OCTET STRING, sessDtePswd OCTET STRING, sessDteId OCTET STRING, sessMaxInPktSize Integer32, sessMaxOutPktSize Integer32, sessCallIndReverse OCTET STRING } sessQllcIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { snaSessQllcEntry 1 } sessQllcId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The unique identifier of the converted SNA session. " ::= { snaSessQllcEntry 2 } sessQllcSide OBJECT-TYPE SYNTAX INTEGER { sideA(1) , sideB(2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The SNA session's side. " ::= { snaSessQllcEntry 3 } sessInCalls OBJECT-TYPE SYNTAX INTEGER { disable(1) , enable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "N/Allowed to accept call indicators (QLLC only) 1- disable: don't allow to accept call indications 2- enable: Allow to accept call indications " ::= { snaSessQllcEntry 4 } sessOutCalls OBJECT-TYPE SYNTAX INTEGER { disable(1) , enable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " N/Allowed to initiate call requests (QLLC only) 1- disable: don't allow to initiate call requests 2- enable: Allow to initiate call requests " ::= { snaSessQllcEntry 5 } sessPVC OBJECT-TYPE SYNTAX INTEGER { disable(1) , enable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " PVC being used or not (QLLC only) 1 - disable :not use 2 - enable :use " ::= { snaSessQllcEntry 6 } sessCallReqData OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION " The user's data for call requests (QLLC only). " ::= { snaSessQllcEntry 7 } sessConnReqFacility OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION " The facilities for connection requests (QLLC only). " ::= { snaSessQllcEntry 8 } sessGroupId OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION " The facility group id (QLLC only) " ::= { snaSessQllcEntry 9 } sessDtePswd OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION " The password for local DTE (QLLC only) " ::= { snaSessQllcEntry 10} sessDteId OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION " The identification for local DTE (QLLC only). " ::= { snaSessQllcEntry 11 } sessMaxInPktSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " The max inbound packet size (QLLC only). " ::= { snaSessQllcEntry 12 } sessMaxOutPktSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " The max outbound packet size (QLLC only). " ::= { snaSessQllcEntry 13 } sessCallIndReverse OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { snaSessQllcEntry 14 } -- -- cvtIfn OBJECT IDENTIFIER ::= {radConverters 2 } cvtSdlc OBJECT IDENTIFIER ::= {cvtIfn 1 } --**************************** --**** SDLC GROUP ********** --**************************** sdlcLinesNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { cvtSdlc 1 } sdlcTable OBJECT-TYPE SYNTAX SEQUENCE OF SdlcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { cvtSdlc 3 } sdlcEntry OBJECT-TYPE SYNTAX SdlcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table sdlcTable." INDEX { sdlcIfIndex } ::= { sdlcTable 1 } SdlcEntry ::= SEQUENCE { sdlcIfIndex Integer32, sdlcNrz INTEGER, sdlcDuplex INTEGER, sdlcClockType INTEGER, sdlcSpeed Integer32, sdlcConnectorType DisplayString, sdlcRts INTEGER } sdlcIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the interface for which this entry contains management information. The value of this object for a particular interface has the same value as the ifIndex object, defined in [4,6], for the same interface." ::= { sdlcEntry 1 } sdlcNrz OBJECT-TYPE SYNTAX INTEGER { nrz(1), nrzi(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { sdlcEntry 2 } sdlcDuplex OBJECT-TYPE SYNTAX INTEGER { half(1), full(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { sdlcEntry 3 } sdlcClockType OBJECT-TYPE SYNTAX INTEGER { external(1), internal(2)} MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { sdlcEntry 4 } sdlcSpeed OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { sdlcEntry 5 } sdlcConnectorType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sdlcEntry 6 } sdlcRts OBJECT-TYPE SYNTAX INTEGER { constatnt(1), controled(2) } MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sdlcEntry 7 } --************** sdlcStatTable OBJECT-TYPE SYNTAX SEQUENCE OF SdlcStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { cvtSdlc 4 } sdlcStatEntry OBJECT-TYPE SYNTAX SdlcStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table sdlcStatTable." INDEX { sdlcStatIfIndex } ::= { sdlcStatTable 1 } SdlcStatEntry ::= SEQUENCE { sdlcStatIfIndex Integer32, sdlcTimeSinceReset TimeTicks, sdlcStatFramesTrans Counter32, sdlcStatBytesTrans Counter32, sdlcStatFramesRcv Counter32, sdlcStatBytesRcv Counter32, sdlcStatFramesAbort Counter32, sdlcStatFramesBad Counter32, sdlcStatFramesCrc Counter32 } sdlcStatIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the interface for which this entry contains management information. The value of this object for a particular interface has the same value as the ifIndex object, defined in [4,6], for the same interface." ::= { sdlcStatEntry 1 } sdlcTimeSinceReset OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-write STATUS current DESCRIPTION " The time laps since the last reset statistics. Setting the object to 0 will reset all line statistics. " ::= { sdlcStatEntry 2 } sdlcStatFramesTrans OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sdlcStatEntry 3 } sdlcStatBytesTrans OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sdlcStatEntry 4 } sdlcStatFramesRcv OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sdlcStatEntry 5 } sdlcStatBytesRcv OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sdlcStatEntry 6 } sdlcStatFramesAbort OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sdlcStatEntry 7 } sdlcStatFramesBad OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " This counter holds the number of all bad frames. " ::= { sdlcStatEntry 8 } sdlcStatFramesCrc OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sdlcStatEntry 9 } -- LAN Token Ring interface -- Private MIB - dot5 / TR interface unit cvtDot5 OBJECT IDENTIFIER ::= { cvtIfn 2 } cvtDot5Table OBJECT-TYPE SYNTAX SEQUENCE OF CvtDot5Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains Token Ring interface parameters and state variables. One entry per 802.3 interface." ::= { cvtDot5 1 } cvtDot5Entry OBJECT-TYPE SYNTAX CvtDot5Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table cvtDot5Table." INDEX { cvtDot5IfIndex } ::= { cvtDot5Table 1 } CvtDot5Entry ::= SEQUENCE { cvtDot5IfIndex Integer32, cvtDot5MacAddr MacAddress, cvtDot5Commands INTEGER, cvtDot5RingSpeed INTEGER, cvtDot5ActMonParticipate INTEGER, cvtDot5Functional MacAddress } cvtDot5IfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the 802.5 interface for which this entry contains management information. The value of this object for a particular interface has the same value as the ifIndex object, defined in [4,6], for the same interface." ::= { cvtDot5Entry 1 } cvtDot5MacAddr OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { cvtDot5Entry 2 } cvtDot5Commands OBJECT-TYPE SYNTAX INTEGER { no-op(1), open(2), reset(3), close(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "When this object is set to the value of open(2), the station should go into the open state. When this object is set to the value of of reset(3), the station should perform reset. When this object is set to the value of close(4), the station should go into the stopped state by removing itself from the ring. Setting this object to a value of no-op(1) has no effect. When read, this object always has a value of no-op(1)." ::= { cvtDot5Entry 3 } cvtDot5RingSpeed OBJECT-TYPE SYNTAX INTEGER { unknown(1), oneMegabit(2), fourMegabit(3), sixteenMegabit(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The ring's bandwidth." ::= { cvtDot5Entry 4 } cvtDot5ActMonParticipate OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "If this object has a value of true(1) then this interface will participate in the active monitor selection process. If the value is false(2) then it will not. Setting this object might not have an effect until the next time the interface is opened." ::= { cvtDot5Entry 5 } cvtDot5Functional OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The bit mask of all TR functional addresses for which this interface will accept frames." ::= { cvtDot5Entry 6 } -- LAN ETHERNET interface -- Private MIB - dot3 interface unit cvtDot3 OBJECT IDENTIFIER ::= { cvtIfn 3 } cvtDot3Table OBJECT-TYPE SYNTAX SEQUENCE OF CvtDot3Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains ETHERNET interface parameters and state variables, one entry per 802.3 interface." ::= { cvtDot3 1 } cvtDot3Entry OBJECT-TYPE SYNTAX CvtDot3Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table cvtDot3Table." INDEX { cvtDot3IfIndex } ::= { cvtDot3Table 1 } CvtDot3Entry ::= SEQUENCE { cvtDot3IfIndex Integer32, cvtDot3MacAddr MacAddress, cvtDot3Commands INTEGER, cvtDot3ActMonParticipate INTEGER, cvtDot3Functional MacAddress } cvtDot3IfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the 802.3 interface for which this entry contains management information. The value of this object for a particular interface has the same value as the ifIndex object, defined in [4,6], for the same interface." ::= { cvtDot3Entry 1 } cvtDot3MacAddr OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { cvtDot3Entry 2 } cvtDot3Commands OBJECT-TYPE SYNTAX INTEGER { no-op(1), open(2), reset(3), close(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "When this object is set to the value of open(2), the station should go into the open state. of reset(3), then the station should do a reset. On a reset, all MIB counters should retain their values, if possible. Other side affects are dependent on the hardware chip set. When this object is set to the value of close(4), the station should go into the stopped state by removing itself from the ring. Setting this object to a value of no-op(1) has no effect. When read, this object always has a value of no-op(1)." ::= { cvtDot3Entry 3 } cvtDot3ActMonParticipate OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "If this object has a value of true(1) then this interface will participate in the active monitor selection process. If the value is false(2) then it will not. Setting this object might not have an effect until the next time the interface is opened." ::= { cvtDot3Entry 4 } cvtDot3Functional OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The bit mask of all Ethernet functional addresses for which this interface will accept frames." ::= { cvtDot3Entry 5 } -- -- file :v:\doc\rdv\mib\Before~1\stkhubgn.txt -- --Version: 1.0 --Date: 17.10.94 --By: Orly Nicklass --File: stkhubgn.txt --Last update: Smadar Tauber 12.02.96 radStkHubEvents OBJECT-IDENTITY STATUS current DESCRIPTION "The events for Rad Stackable General products." ::= { radStkHub 0 } stkHubGen OBJECT IDENTIFIER ::= { radStkHub 1 } -- Rad Stackable General stkHubGenAgn OBJECT IDENTIFIER ::= { stkHubGen 1 } -- Rad Stackable Agent -- Stackable Hub's agent general parameters stkHubAgentResetConfig OBJECT-TYPE SYNTAX INTEGER { off(2), on(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting the value to ON(3)is interpreted as a reset command for the agent NV Ram. When reset process is ended, a trap will be issued. " ::= { stkHubGenAgn 1 } stkHubAgentSpecific OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION " Object identifier of entity containing additional information regarding this instance." ::= { stkHubGenAgn 2 } -- Hub's Security parameters stkHubSecurityTable OBJECT-TYPE SYNTAX SEQUENCE OF StkHubSecurityEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Hub's Security parameters." ::= { stkHubGen 2 } stkHubSecurityEntry OBJECT-TYPE SYNTAX StkHubSecurityEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table stkHubSecurityTable." INDEX { stkHubSecID } ::= { stkHubSecurityTable 1 } StkHubSecurityEntry ::= SEQUENCE { stkHubSecID Integer32, stkHubSecEnable INTEGER, stkHubSecurityPattern OCTET STRING, stkHubSecurityMask OCTET STRING } stkHubSecID OBJECT-TYPE SYNTAX Integer32 (1..3) MAX-ACCESS read-only STATUS current DESCRIPTION "Segment's security unique identification number" ::= { stkHubSecurityEntry 1 } stkHubSecEnable OBJECT-TYPE SYNTAX INTEGER { off(2), on(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This entry indicates whether the specific segment's security is active or not" ::= { stkHubSecurityEntry 2 } stkHubSecurityPattern OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "A six-octet(48 bit) pattern: where the masked bits of stkHubSecurityMask need to match the MAC address of each port within the segment.Value of all zeros indicates no security." ::= { stkHubSecurityEntry 3 } stkHubSecurityMask OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Mask of the allowed MAC address that can be connected through the ports within the segment" ::= { stkHubSecurityEntry 4 } -- Port Security parameters stkHubPrtSecurityTable OBJECT-TYPE SYNTAX SEQUENCE OF StkHubPrtSecurityEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Port Security parameters." ::= { stkHubGen 3 } stkHubPrtSecurityEntry OBJECT-TYPE SYNTAX StkHubPrtSecurityEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table stkHubPrtSecurityTable." INDEX { stkHubModuleID, stkHubPrtID, stkHubPrtSecID } ::= { stkHubPrtSecurityTable 1 } StkHubPrtSecurityEntry ::= SEQUENCE { stkHubModuleID Integer32, stkHubPrtID Integer32, stkHubPrtSecID Integer32, stkHubPrtSecurityEnable INTEGER, stkHubPrtSecurityPattern OCTET STRING, stkHubPrtSecurityMask OCTET STRING } stkHubModuleID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier of the module(slot no.)this port is attached to." ::= { stkHubPrtSecurityEntry 1 } stkHubPrtID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier of the port within its module." ::= { stkHubPrtSecurityEntry 2 } stkHubPrtSecID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier of the security of a given port within its module." ::= { stkHubPrtSecurityEntry 3 } stkHubPrtSecurityEnable OBJECT-TYPE SYNTAX INTEGER { unknown(1), off(2), on(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The value of this attribute determines application of the port security." ::= { stkHubPrtSecurityEntry 4 } stkHubPrtSecurityPattern OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "A six-octet(48 bit) pattern: where the masked bits of stkHubPortSecurityMask need to match the MAC address." ::= { stkHubPrtSecurityEntry 5 } stkHubPrtSecurityMask OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Mask of the allowed MAC address that can be connected through this port. The security of the individual port over writes the security of the segment where the port belongs to" ::= { stkHubPrtSecurityEntry 6 } -- Traps are defined using the conventions in RFC 1215 [6]. softErrors NOTIFICATION-TYPE STATUS current DESCRIPTION " This trap is sent when the software errors threshold is exceeded." ::= { radStkHubEvents 33 } resetRequired NOTIFICATION-TYPE OBJECTS { trimErrorDesc, trimErrorSeverity, agnLed} STATUS current DESCRIPTION "This trap indicates that in order to perform the last SET request, a reset operation of the router/bridge is required. This occurs when the layer 2 routing algorithm is changed between SPF and Spanning Tree. The reset can be performed manually or using the variable radBridgeAction." ::= { radRBHEEvents 10 } compNotActive NOTIFICATION-TYPE OBJECTS { trimErrorDesc, trimErrorSeverity, agnLed} STATUS current DESCRIPTION "Compression was enabled but cannot be activated, since connected device does not support correct compression. " ::= { radRBHEEvents 20 } noCompression NOTIFICATION-TYPE OBJECTS { trimErrorDesc, trimErrorSeverity, agnLed} STATUS current DESCRIPTION "Compression card not present." ::= { radRBHEEvents 21 } errorBackUp NOTIFICATION-TYPE OBJECTS { trimErrorDesc, trimErrorSeverity, agnLed} STATUS current DESCRIPTION "Automatic switchover to backup link because of excessive link errors." ::= { radRBHEEvents 22 } faultBackUp NOTIFICATION-TYPE OBJECTS { trimErrorDesc, trimErrorSeverity, agnLed} STATUS current DESCRIPTION "Automatic switchover to backup link because of main link fault." ::= { radRBHEEvents 23 } mainLinkUp NOTIFICATION-TYPE OBJECTS { trimErrorDesc, trimErrorSeverity, agnLed} STATUS current DESCRIPTION "Communication returned to main link." ::= { radRBHEEvents 24 } failedDialUp NOTIFICATION-TYPE OBJECTS { trimErrorDesc, trimErrorSeverity, agnLed} STATUS current DESCRIPTION "Cannot establish backup dial-up connection." ::= { radRBHEEvents 25 } extLoopBack NOTIFICATION-TYPE OBJECTS { trimErrorDesc, trimErrorSeverity, agnLed} STATUS current DESCRIPTION " This trap is sent when Loopback starts on the link. " ::= { radRBHEEvents 29 } dialUpConnFailed NOTIFICATION-TYPE OBJECTS { trimErrorDesc, trimErrorSeverity, agnLed } STATUS current DESCRIPTION " This trap is sent when the dialUp connection is terminated due to a failure." ::= { radRBHEEvents 41 } dialUpConnEstablished NOTIFICATION-TYPE OBJECTS { trimErrorDesc, trimErrorSeverity, agnLed } STATUS current DESCRIPTION " This trap is sent when the dialUp connection is established." ::= { radRBHEEvents 42 } dialUpConnTerminated NOTIFICATION-TYPE OBJECTS { trimErrorDesc, trimErrorSeverity, agnLed } STATUS current DESCRIPTION " This trap is sent when the dialUp connection is normally terminated." ::= { radRBHTEvents 43 } -- -- file :v:\doc\rdv\mib\Before~1\stkhubtr.txt -- --Title: STK-T-MIB --Version: 2.0 --Date: 9-aug-94 --By: Orly Nicklass & Rina Nathaniel & Benny Dolnik --File: STKHUBTR.TXT --Update: 26-December-95 -- Ring information for the ring the agent is connected to. stkHubTR OBJECT IDENTIFIER ::= { radStkHub 2 } -- Stackable Token Ring stkHubTRRing OBJECT IDENTIFIER ::= { stkHubTR 1} stkHubTRRingCorrelationEnable OBJECT-TYPE SYNTAX INTEGER { off(2), on(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "When set to ON(3), the in-band agent should perform correlation each time a station enters/leaves the segment." ::= { stkHubTRRing 1 } stkHubTRRingAutorecEnable OBJECT-TYPE SYNTAX INTEGER { off(2), on(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "When set to ON(3), the in-band agent should perform autorecovery each time a beacon status is detected." ::= { stkHubTRRing 2 } stkHubTRRingAutorecResult OBJECT-TYPE SYNTAX INTEGER { not-started(1), started(2), segment-ok(3), segment-fixed(4), segment-closed(5), failed(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "When autorecovery is completed the result will be recorded. While in process, STARTED will be recorded.Before process, NOT STARTED will be recorded" ::= { stkHubTRRing 3 } stkHubTRRingResetStatistics OBJECT-TYPE SYNTAX INTEGER { unknown(1), off(2), on(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting the value of this attribute to ON(3) resets all the inband statistics and error counters." ::= { stkHubTRRing 4 } stkHubTRRingLineErrCnt OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is incremented when a frame or token is copied or repeated by any of the stations on the ring, the E bit is zero in the frame or token and one of the following conditions exists: 1) there is a non-data bit (J or K bit) between the SD and the ED of the frame or token, or 2) there is an FCS error in the frame." ::= { stkHubTRRing 5 } stkHubTRRingBurstErrCnt OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is incremented when any of the stations on the ring detects the absence of transitions for five half-bit timers (burst-five error)." ::= { stkHubTRRing 6 } stkHubTRRingACFCErrCnt OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is incremented when any of the stations on the ring receives an AMP or SMP frame in which A is equal to C is equal to 0, and then receives another SMP frame with A is equal to C is equal to 0 without first receiving an AMP frame. It denotes a station that cannot set the AC bits properly." ::= { stkHubTRRing 7 } stkHubTRRingTotErrCnt OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total of the above described errors" ::= { stkHubTRRing 8 } stkHubTRRingTotErrThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The Total Errors Threshold value. A trap indicating Soft Error will be sent, if the total number of errors during the last 10 seconds, reached the threshold value. Threshold value = 0 , disables this trap." ::= { stkHubTRRing 9} stkHubTRRingTotalFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total frames of the Ring." ::= { stkHubTRRing 10 } stkHubTRRingTotalFramesRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The rate of total frames on the Ring." ::= { stkHubTRRing 11 } stkHubTRRingTotalOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total octets of the Ring." ::= { stkHubTRRing 12 } stkHubTRRingOctetsRatio OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Current traffic for the last time interval. The traffic is expressed in percents of the maximum TokenRing traffic ." ::= { stkHubTRRing 13 } -- Bridge Hub Module table for TR media type -- Contains general information about the Module stkHubTRMdl OBJECT IDENTIFIER ::= { stkHubTR 2} stkHubTRMdlTable OBJECT-TYPE SYNTAX SEQUENCE OF StkHubTRMdlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Bridge Hub Module table for TR media type Contains general information about the Module" ::= { stkHubTRMdl 1 } stkHubTRMdlEntry OBJECT-TYPE SYNTAX StkHubTRMdlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table stkHubTRMdlTable." INDEX {stkHubTRMdlID} ::= { stkHubTRMdlTable 1} StkHubTRMdlEntry ::= SEQUENCE { stkHubTRMdlID Integer32, stkHubTRMdlType INTEGER, stkHubTRMdlReset INTEGER, stkHubTRMdlLed OCTET STRING, stkHubTRMdlSpeed INTEGER, stkHubTRMdlMngState INTEGER, stkHubTRMdlAutodisable INTEGER, stkHubTRMdlConfigMsg OCTET STRING } stkHubTRMdlID OBJECT-TYPE SYNTAX Integer32 (1..10) MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier of the module in stack. Internal module identifier is always 1 " ::= {stkHubTRMdlEntry 1} stkHubTRMdlType OBJECT-TYPE SYNTAX INTEGER { unknown(1), sah16int(2), sah16ext(3), empty(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the type of the module connected with specific identifier " ::= {stkHubTRMdlEntry 2 } stkHubTRMdlReset OBJECT-TYPE SYNTAX INTEGER { unknown(1), off(2), on(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "When this object is set to the value of ON(3), the module performs software reset. Upon completion, a trap will be issued to the management station and the value will be set to OFF." ::= {stkHubTRMdlEntry 3} stkHubTRMdlLed OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This entry specifies the LEDs status in the module . Each led will be represented by 4 bits where the first 2 bits will specify the status (NA, OFF, ON, BLINK), and the next two bits will specify the color (RED, GREEN, YELLOW)" ::= {stkHubTRMdlEntry 4} stkHubTRMdlSpeed OBJECT-TYPE SYNTAX INTEGER { unknown(1), fourMegabit(2), sixteenMegabit(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Attribute describing the bandwidth of the media as set by the module switch. For certain products, if the value of stkHubTRMdlMngState is 'enabled', then stkHubTRMdlSpeed can be set to the desired value. Else, it will be read-only, and will show the status of the jumper set of the main module. Refer product's manual." ::= { stkHubTRMdlEntry 5} stkHubTRMdlMngState OBJECT-TYPE SYNTAX INTEGER { unknown (1), disabled(2), enabled (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the status of the Manage switch as set on the back panel of the main module. 'enabled' - means that management can override setting of some HW switch/es." ::= {stkHubTRMdlEntry 6 } stkHubTRMdlAutodisable OBJECT-TYPE SYNTAX INTEGER { unknown(1), off(2), on(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Attribute describing the status of port Autodisable mechanism, that protects against inserting in Token Ring adapters at the wrong speed. For certain products, if the value of stkHubTRMdlMngState is 'enabled', then stkHubTRMdlAutodisable can be set to the desired value. Else, it will be read-only, and will show the status of the jumper set of the main module. Refer product's manual." ::= {stkHubTRMdlEntry 7 } stkHubTRMdlConfigMsg OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Full configuration message coded in internal RND application format. This entry describes module' configuration. " ::= {stkHubTRMdlEntry 8} -- Bridge Hub port table for TR media type -- Contains general information about the ports. stkHubTRPrt OBJECT IDENTIFIER ::= { stkHubTR 3} stkHubTRPrtTable OBJECT-TYPE SYNTAX SEQUENCE OF StkHubTRPrtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Bridge Hub port table for TR media type Contains general information about the ports." ::= { stkHubTRPrt 1 } stkHubTRPrtEntry OBJECT-TYPE SYNTAX StkHubTRPrtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table stkHubTRPrtTable." INDEX { stkHubTRPrtMdlID, stkHubTRPrtID } ::= { stkHubTRPrtTable 1 } StkHubTRPrtEntry ::= SEQUENCE { stkHubTRPrtMdlID Integer32, stkHubTRPrtID Integer32, stkHubTRPrtFunctionality INTEGER, stkHubTRPrtConnectorType INTEGER, stkHubTRPrtAdminCmd INTEGER, stkHubTRPrtActiveState INTEGER, stkHubTRPrtTrapMaskEnable INTEGER, stkHubTRPrtStatus INTEGER, stkHubTRPrtCableProtectEnable INTEGER, stkHubTRPrtFlipProtectEnable INTEGER, stkHubTRPrtMACAddress MacAddress, stkHubTRPrtType INTEGER } stkHubTRPrtMdlID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier of the module this port is attached to." ::= { stkHubTRPrtEntry 1 } stkHubTRPrtID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier of the port within its module." ::= { stkHubTRPrtEntry 2 } stkHubTRPrtFunctionality OBJECT-TYPE SYNTAX INTEGER { unknown(1), ringin(2) , ringout(3) , satellite(4), lobe(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Describes the functionality of the port in a Token ring topology" ::= { stkHubTRPrtEntry 3 } stkHubTRPrtConnectorType OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), idc(2), rj45(3), srJ45(4), db9(5), bnc(6), fo-st(7), db25(8) -- fo-sma(8), -- fo-fc(9) } MAX-ACCESS read-only STATUS current DESCRIPTION "Type of hardware connector in the port." ::= { stkHubTRPrtEntry 4 } stkHubTRPrtAdminCmd OBJECT-TYPE SYNTAX INTEGER { unknown(1), disable(2), enable(3), short(4), normal(5) } MAX-ACCESS read-write STATUS current DESCRIPTION "By setting this attribute to DISABLE(2) or SHORT(4) the management station can force this lobe/port-connection to be removed and block any access to the network via this lobe/port. It is not mandatory that a certain lobe/port will support all the enumerated states. The state of the lobe/port is type specific and indicated within the specific group" ::= { stkHubTRPrtEntry 5 } stkHubTRPrtActiveState OBJECT-TYPE SYNTAX INTEGER { unknown(1), off(2), on(3), standby(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute describes the electrical or optical activity state of a lobe or the state of a port. Certain values may not be applicable in some cases" ::= { stkHubTRPrtEntry 6 } stkHubTRPrtTrapMaskEnable OBJECT-TYPE SYNTAX INTEGER { off(2), on(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "When this attribute is set to OFF by the management console the agent starts sending the unmasked traps related to this port. Otherwise no traps from this port are sent." ::= { stkHubTRPrtEntry 7 } stkHubTRPrtStatus OBJECT-TYPE SYNTAX INTEGER { unknown(1), disabledManual(2), disabledAutorec(3), disabledSecurity(4), disabledAuto(5), disabledFlip(6), inserted(7), bypass(8), forcedloop(9), trunkfail(10), normal(11) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the status of this lobe/port connection: DISABLED-(2) to (6) indicates the reason for the disabled state. INSERTED(7)indicates that the lobe hardware inserts this lobe into the ring , thus it becomes part of the ring BYPASSED(8)indicates that the ring bypasses this lobe and the lobe hardware provides loopback connection towards the station for media test purposes. FORCEDLOOP(9) indicates the port is in a loopback state and the main ring is connected to the backup path. TRUNKFAIL (10) indicates that the ring connection is broken for a repeater, converter or a cable protector. NORMAL(11) indicates the port is in normal condition It is not mandatory that a certain lobe/port will support all the enumerated states." ::= { stkHubTRPrtEntry 8 } stkHubTRPrtCableProtectEnable OBJECT-TYPE SYNTAX INTEGER { unknown(1), off(2), on(3), inhibit(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this attribute determines activation of the cable-fault protection mechanism of TCR and the optical link mechanism of TFR and TFC ." ::= { stkHubTRPrtEntry 9 } stkHubTRPrtFlipProtectEnable OBJECT-TYPE SYNTAX INTEGER { unknown(1), off(2), on(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The value of this attribute determines activation of the flipping-lobe protection mechanism of the port." ::= { stkHubTRPrtEntry 10 } stkHubTRPrtMACAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION " The value of this object is the specific MAC address of this interface which uniquely identifies this Interface on a ring." ::= { stkHubTRPrtEntry 11 } stkHubTRPrtType OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), tfr(2), tfc(3), tcr(4), tcp(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Type of the port specific hardware" ::= { stkHubTRPrtEntry 12} -- TRAPS --NOTIFICATIONS stkHubTREvents OBJECT-IDENTITY STATUS current DESCRIPTION "The events for Stackable Token Ring." ::= { stkHubTR 0 } macAddressUpdated NOTIFICATION-TYPE OBJECTS { stkHubTRPrtMACAddress } STATUS current DESCRIPTION "This trap will be sent upon every change of MACAddress on a port." ::= { stkHubTREvents 91 } mdlStatusChanged NOTIFICATION-TYPE OBJECTS { stkHubTRMdlLed, stkHubTRMdlType } STATUS current DESCRIPTION "This trap is sent each time module status was changed.When a module is disconnected, the stkHubTRMdlLed status will be 00 (no led) and the stkHubTRMdlType will be empty(255)." ::= { stkHubTREvents 27 } ringBeaconing NOTIFICATION-TYPE OBJECTS { trimErrorDesc, trimErrorSeverity, agnLed } STATUS current DESCRIPTION "This trap is sent when Token Ring LAN is beaconing." ::= { radRBHTEvents 30 } lanAdapterRemoved NOTIFICATION-TYPE OBJECTS { trimErrorDesc, trimErrorSeverity, agnLed } STATUS current DESCRIPTION "This trap is sent when Token Ring LAN adapter was removed by LAN manager." ::= { radRBHTEvents 31 } -- -- file :v:\doc\rdv\mib\Before~1\stkhubet.txt -- --Title: STK-E-MIB -- Version: 1.0 --Date: 9.10.94 --By: Orly Nicklass & Rina Nathaniel & Benny Dolnik --File: STKHUBET.TXT --Update: 09.03.95 stkHubET OBJECT IDENTIFIER ::= { radStkHub 3 } -- Stackable Ethernet -- Bridge Hub Module table for ET media type -- Contains general information about the Module stkHubETMdl OBJECT IDENTIFIER ::= { stkHubET 2} stkHubETMdlTable OBJECT-TYPE SYNTAX SEQUENCE OF StkHubETMdlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Bridge Hub Module table for ET media type Contains general information about the Module" ::= { stkHubETMdl 1 } stkHubETMdlEntry OBJECT-TYPE SYNTAX StkHubETMdlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table stkHubETMdlTable." INDEX {stkHubETMdlID} ::= { stkHubETMdlTable 1} StkHubETMdlEntry ::= SEQUENCE { stkHubETMdlID Integer32, stkHubETMdlLed OCTET STRING, stkHubETMdlReset INTEGER } stkHubETMdlID OBJECT-TYPE SYNTAX Integer32 (1..10) MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier of the module in stack. Internal module identifier is always 1 " ::= {stkHubETMdlEntry 1} stkHubETMdlLed OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This entry specifies the LEDs status in the module . Each led will be represented by 4 bits where the first 2 bits will specify the status (NA, OFF, ON, BLINK), and the next two bits will specify the color (RED, GREEN, YELLOW)" ::= {stkHubETMdlEntry 2} stkHubETMdlReset OBJECT-TYPE SYNTAX INTEGER { unknown(1), off(2), hwReset(3), configReset(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "When this object is set to the value of hwReset(3), the module performs HW reset. When this object is set to the value of configReset(4), the module performs Configuration reset. Upon completion, a trap will be issued to the management station and the value will be set to OFF." ::= {stkHubETMdlEntry 3} -- Traps are defined using the conventions in RFC 1215 [6]. portStatusChanged NOTIFICATION-TYPE OBJECTS { stkHubETMdlLed, rpMauMediaAvailable, rptrPortOperStatus } STATUS current DESCRIPTION "This trap is sent each time port status was changed." ::= { radStkHubEvents 26 } -- -- file :v:\doc\rdv\mib\Before~1\etrptr.txt -- --Title: ET-RPTR-MIB --Version: 1.0 --Date: 26-JAN-94 --By: Orly Nicklass --File: ETRPTR.TXT --Update: 12-MAR-95 -- Basic Repeater Information -- -- Configuration, status, and control objects for the overall -- repeater -- radEthRptr OBJECT IDENTIFIER ::= { rad 9 } -- Ethernet Repeaters products etRptrTable OBJECT-TYPE SYNTAX SEQUENCE OF EtRptrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains repeater data specific to the etRptrIndex." ::= { radEthRptr 1 } etRptrEntry OBJECT-TYPE SYNTAX EtRptrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table etRptrTable." INDEX { etRptrIndex } ::= { etRptrTable 1 } EtRptrEntry ::= SEQUENCE { etRptrIndex Integer32, etRptrGroupCapacity Integer32, etRptrOperStatus INTEGER, etRptrHealthText DisplayString, etRptrReset INTEGER, etRptrNonDisruptTest INTEGER, etRptrTotalPartitionedPorts Gauge32, etRptrMdlVector Integer32, etRptrMonitorTransmitCollisions Counter32 } etRptrIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The Repeater Id, this table data refer to." ::= { etRptrEntry 1 } etRptrGroupCapacity OBJECT-TYPE SYNTAX Integer32 (1..1024) MAX-ACCESS read-only STATUS current DESCRIPTION "The etRptrGroupCapacity is the number of groups that can be contained within the repeater. Within each managed repeater, the groups are uniquely numbered in the range from 1 to etRptrGroupCapacity. Some groups may not be present in the repeater, in which case the actual number of groups present will be less than etRptrGroupCapacity. The number of groups present will never be greater than etRptrGroupCapacity. Note: In practice, this will generally be the number of field-replaceable units (i.e., modules, cards, or boards) that can fit in the physical repeater enclosure, and the group numbers will correspond to numbers marked on the physical enclosure." REFERENCE "Reference IEEE 802.3 Rptr Mgt, 19.2.3.2, RepeaterGroupCapacity." ::= { etRptrEntry 2 } etRptrOperStatus OBJECT-TYPE SYNTAX INTEGER { other(1), -- undefined or unknown status ok(2), -- no known failures rptrFailure(3), -- repeater-related failure groupFailure(4), -- group-related failure portFailure(5), -- port-related failure generalFailure(6) -- failure, unspecified type } MAX-ACCESS read-only STATUS current DESCRIPTION "The etRptrOperStatus object indicates the operational state of the repeater. The etRptrHealthText object may be consulted for more specific information about the state of the repeater's health. In the case of multiple kinds of failures (e.g., repeater failure and port failure), the value of this attribute shall reflect the highest priority failure in the following order, listed highest priority first: rptrFailure(3) groupFailure(4) portFailure(5) generalFailure(6)." REFERENCE "Reference IEEE 802.3 Rptr Mgt, 19.2.3.2, aRepeaterHealthState." ::= { etRptrEntry 3 } etRptrHealthText OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The health text object is a text string that provides information relevant to the operational state of the repeater. Agents may use this string to provide detailed information on current failures, including how they were detected, and/or instructions for problem resolution. The contents are agent-specific." REFERENCE "Reference IEEE 802.3 Rptr Mgt, 19.2.3.2, aRepeaterHealthText." ::= { etRptrEntry 4 } etRptrReset OBJECT-TYPE SYNTAX INTEGER { noReset(1), resetHW(2), resetConfig(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this object to reset(2) causes a transition to the START state of Fig 9-2 in section 9 [IEEE 802.3 Std]. Setting this object to noReset(1) has no effect. The agent will always return the value noReset(1) when this object is read. After receiving a request to set this variable to resetHW(2), the agent is allowed to delay the reset for a short period. For example, the implementor may choose to delay the reset long enough to allow the SNMP response to be transmitted. In any event, the SNMP response must be transmitted. This action does not reset the management counters defined in this document nor does it affect the portAdminStatus parameters. Included in this action is the execution of a disruptive Self-Test with the following characteristics: a) The nature of the tests is not specified. b) The test resets the repeater but without affecting management information about the repeater. c) The test does not inject packets onto any segment. d) Packets received during the test may or may not be transferred. e) The test does not interfere with management functions. After performing this self-test, the agent will update the repeater health information (including etRptrOperStatus and etRptrHealthText), and send a etRptrHealth trap. Setting this object to resetConfig(3) will cause resetting the repeater to its default values." REFERENCE "Reference IEEE 802.3 Rptr Mgt, 19.2.3.3, acResetRepeater." ::= { etRptrEntry 5 } etRptrNonDisruptTest OBJECT-TYPE SYNTAX INTEGER { noSelfTest(1), selfTest(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this object to selfTest(2) causes the repeater to perform a agent-specific, non- disruptive self-test that has the following characteristics: a) The nature of the tests is not specified. b) The test does not change the state of the repeater or management information about the repeater. c) The test does not inject packets onto any segment. d) The test does not prevent the relay of any packets. e) The test does not interfere with management functions. After performing this test, the agent will update the repeater health information (including etRptrOperStatus and etRptrHealthText) and send a etRptrHealth trap. Note that this definition allows returning an 'okay' result after doing a trivial test. Setting this object to noSelfTest(1) has no effect. The agent will always return the value noSelfTest(1) when this object is read." REFERENCE "Reference IEEE 802.3 Rptr Mgt, 19.2.3.3, acExecuteNonDisruptiveSelfTest." ::= { etRptrEntry 6 } etRptrTotalPartitionedPorts OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object returns the total number of ports in the repeater whose current state meets all three of the following criteria: etRptrPortOperStatus does not have the value notPresent(3), etRptrPortAdminStatus is enabled(1), and etRptrPortAutoPartitionState is autoPartitioned(2)." ::= { etRptrEntry 7 } etRptrMdlVector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object returns a vector mapping the location of the repeater modules to their corresponding bit position. A bit that is set indicates an existing module " ::= { etRptrEntry 8 } -- -- Repeater Monitor Information -- -- Performance monitoring statistics for the repeater -- etRptrMonitorTransmitCollisions OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is incremented every time the repeater state machine enters the TRANSMIT COLLISION state from any state other than ONE PORT LEFT (Ref: Fig 9-2, IEEE 802.3 Std). The approximate minimum time for rollover of this counter is 16 hours." REFERENCE "Reference IEEE 802.3 Rptr Mgt, 19.2.3.2, aTransmitCollisions." ::= { etRptrEntry 9 } -- Repeater Security Table etRptrSecTable OBJECT-TYPE SYNTAX SEQUENCE OF EtRptrSecEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Repeater Security Table" ::= { radEthRptr 2 } etRptrSecEntry OBJECT-TYPE SYNTAX EtRptrSecEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table etRptrSecTable." INDEX {etRptrId, etRptrSecID } ::= { etRptrSecTable 1 } EtRptrSecEntry ::= SEQUENCE { etRptrId Integer32, etRptrSecID Integer32, etRptrSecEnable INTEGER, etRptrSecPattern OCTET STRING, etRptrSecMask OCTET STRING } etRptrId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The Repeater Id, this table data refer to." ::= { etRptrSecEntry 1 } etRptrSecID OBJECT-TYPE SYNTAX Integer32 (1..3) MAX-ACCESS read-only STATUS current DESCRIPTION "Segment's security unique identification number" ::= { etRptrSecEntry 2 } etRptrSecEnable OBJECT-TYPE SYNTAX INTEGER { off(2), on(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This entry indicates whether the specific segment's security is active or not" ::= { etRptrSecEntry 3 } etRptrSecPattern OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "A six-octet(48 bit) pattern: where the masked bits of etRptrSecMask need to match the MAC address of each port within the segment.Value of all zeros indicates no security." ::= { etRptrSecEntry 4 } etRptrSecMask OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Mask of the allowed MAC address that can be connected through the ports within the segment" ::= { etRptrSecEntry 5 } --NOTIFICATIONS radEthRptrEvents OBJECT-IDENTITY STATUS current DESCRIPTION "The events for Ethernet Repeater." ::= { radEthRptr 0 } etRptrHealth NOTIFICATION-TYPE OBJECTS { etRptrOperStatus, rptrGroupOperStatus, agnLed } STATUS current DESCRIPTION "The etRptrHealth trap conveys information related to the operational status of the repeater. This trap is sent either when the value of etRptrOperStatus changes, or upon completion of a non-disruptive test. See the etRptrOperStatus object for descriptions of the information that is sent. The agent must throttle the generation of consecutive etRptrHealth traps so that there is at least a five-second gap between traps of this type. When traps are throttled, they are dropped, not queued for sending at a future time. (Note that 'generating' a trap means sending to all configured recipients.)" REFERENCE "Reference IEEE 802.3 Rptr Mgt, 19.2.3.4, hubHealth notification." ::= { radEthRptrEvents 1 } etRptrResetEvent NOTIFICATION-TYPE OBJECTS { etRptrOperStatus, etRptrIndex, agnLed } STATUS current DESCRIPTION "The etRptrResetEvent trap conveys information related to the operational status of the repeater. This trap is sent on completion of a repeater reset action. A repeater reset action is defined as an a transition to the START state of Fig 9-2 in section 9 [IEEE 802.3 Std], when triggered by a management command (e.g., an SNMP Set on the etRptrReset object). The agent must throttle the generation of consecutive etRptrResetEvent traps so that there is at least a five-second gap between traps of this type. When traps are throttled, they are dropped, not queued for sending at a future time. (Note that 'generating' a trap means sending to all configured recipients.) The etRptrResetEvent trap is not sent when the agent restarts and sends an SNMP coldStart or warmStart trap. However, it is recommended that a repeater agent send the etRptrOperStatus object as an optional object with its coldStart and warmStart trap PDUs. The etRptrOperStatus object must be included in the varbind list sent with this trap. The agent may optionally include the etRptrHealthText object as well." REFERENCE "Reference IEEE 802.3 Rptr Mgt, 19.2.3.4, hubReset notification." ::= { radEthRptrEvents 2 } etRptrConfig NOTIFICATION-TYPE OBJECTS { etRptrMdlVector, agnLed } STATUS current DESCRIPTION " This trap is sent upon every change of the etRptrMdlVector object." ::= { radEthRptrEvents 3 } -- -- file :v:\doc\rdv\mib\ver485\mpmx.txt -- --Title: RAD's WAN PRODUCTS MIB --Version: 1.0 --Date: 31.1.1993 --By: Yaira Gabay, Orly Nicklass --Update : 10.11.1994 --By: Arik Sadovski --Last Update: 09-Sep-2002 --By: Smadar Tauber --File: v:\doc\rdv\mib\ver485\mpmx.txt --IMPORTS -- enterprises FROM RFC1155-SMI -- DisplayString FROM RFC1213-MIB -- IpAddress FROM RFC1155-SMI -- OCTET STRING FROM RFC1213-MIB -- OBJECT-TYPE FROM RFC1212; --Some MIB compilers need those two lines: -- enterprises OBJECT IDENTIFIER ::= -- { iso org(3) dod(6) internet(1) private(4) 1 } --systems OBJECT IDENTIFIER ::= { radGen 1} --agnt OBJECT IDENTIFIER ::= { radGen 2} --radSysWan OBJECT IDENTIFIER ::= { systems 3 } -- ----------------------------------------------------------------------------- wanGen OBJECT IDENTIFIER ::= {radWan 1} muxHub OBJECT IDENTIFIER ::= {radWan 2} -- ---------------------------------------------------------------------------------------------- chasWanGen OBJECT IDENTIFIER ::= {wanGen 1} agnWanGen OBJECT IDENTIFIER ::= {wanGen 2} mdlWanGen OBJECT IDENTIFIER ::= {wanGen 3} prtWanGen OBJECT IDENTIFIER ::= {wanGen 4} mapWanGen OBJECT IDENTIFIER ::= {wanGen 5} diverseIfWanGen OBJECT IDENTIFIER ::= {wanGen 6} --ethIf OBJECT IDENTIFIER ::= {diverseIfWanGen 1} (see ethif.txt) --sonetInterface OBJECT IDENTIFIER ::= {diverseIfWanGen 2} (see radsonet.txt) --ds3Interface OBJECT IDENTIFIER ::= {diverseIfWanGen 3} (see radds3.txt) --ds1Interface OBJECT IDENTIFIER ::= {diverseIfWanGen 4} (see radds1.txt) --hdlcMibObjects OBJECT IDENTIFIER ::= {diverseIfWanGen 5} (see radhdlc.txt) --v51If OBJECT IDENTIFIER ::= {diverseIfWanGen 6} (see v51.txt) --ip2If OBJECT IDENTIFIER ::= {diverseIfWanGen 7} (see ipmux.txt) --broadbandIf OBJECT IDENTIFIER ::= {diverseIfWanGen 8} (see bdband.txt) --r2If OBJECT IDENTIFIER ::= {diverseIfWanGen 9} (see r2.txt) --adslIf OBJECT IDENTIFIER ::= {diverseIfWanGen 10} (see radadsl.txt) --sdslIf OBJECT IDENTIFIER ::= {diverseIfWanGen 11} (see radsdsl.txt) --shdslIf OBJECT IDENTIFIER ::= {diverseIfWanGen 12} (see radshdsl.txt) --voipWanGen OBJECT IDENTIFIER ::= {wanGen 7} (see voip.txt) statAgnGen OBJECT IDENTIFIER ::= {agnWanGen 1} cnfgAgnGen OBJECT IDENTIFIER ::= {agnWanGen 2} cmprAgnGen OBJECT IDENTIFIER ::= {agnWanGen 3} alrBuffGen OBJECT IDENTIFIER ::= {agnWanGen 4} agnFlipDb OBJECT IDENTIFIER ::= {agnWanGen 5} agnSa OBJECT IDENTIFIER ::= {agnWanGen 6} agnListDecoding OBJECT IDENTIFIER ::= {agnWanGen 7} agnSystemDlci OBJECT IDENTIFIER ::= {agnWanGen 8} agnVoiceSwitching OBJECT IDENTIFIER ::= {agnWanGen 9} agnSigProfile OBJECT IDENTIFIER ::= {agnWanGen 10} agnSystemTs OBJECT IDENTIFIER ::= {agnWanGen 11} systemVoice OBJECT IDENTIFIER ::= {agnWanGen 12} statMdlGen OBJECT IDENTIFIER ::= {mdlWanGen 1} cnfgMdlGen OBJECT IDENTIFIER ::= {mdlWanGen 2} cmprMdlGen OBJECT IDENTIFIER ::= {mdlWanGen 3} statPrtGen OBJECT IDENTIFIER ::= {prtWanGen 1} cnfgPrtGen OBJECT IDENTIFIER ::= {prtWanGen 2} cmprPrtGen OBJECT IDENTIFIER ::= {prtWanGen 3} agnMux OBJECT IDENTIFIER ::= {muxHub 1} mdlMux OBJECT IDENTIFIER ::= {muxHub 2} prtMux OBJECT IDENTIFIER ::= {muxHub 3} statPrtMux OBJECT IDENTIFIER ::= {prtMux 1} cnfgPrtMux OBJECT IDENTIFIER ::= {prtMux 2} -- --prtHsfStatTable OBJECT IDENTIFIER ::= {statPrtMux 6} -- prtClCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 1} prtPh1MlCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 2} --MPH1/e1/t1 prtPhPlCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 3} --MPH1,MPH3,MPL6 prtLs2Cnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 4} --LS2 family --prtVc2CnfgTable OBJECT IDENTIFIER ::= {cnfgPrtMux 5} --prtHsfCnfgTable OBJECT IDENTIFIER ::= {cnfgPrtMux 6} prtHs4Cnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 7} prtHsiCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 8} prtPVc4Cnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 9} prtHsrCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 10} prtMbeCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 11} prtTreCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 12} prtLs6Cnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 13} prtVc3Cnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 14} prtVcPbxCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 15} prtIsdnCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 16} prtLogicalCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 17} prtFrPlusCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 18} prtMl4Cnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 19} prtAcmCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 20} prtE2Cnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 21} -- -- Wan chassis general information -- chasVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "An ASCII string for description and display of the agent chassis version." ::= { chasWanGen 1 } chasTotalNoOfSlt OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This entry indicates the number of physical slots in the chassis." ::= { chasWanGen 2 } chasTotalNoOfIoSlt OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This entry indicates the total number of physical IO slots in the chassis, (not all slots hardware should be occupied and active) ." ::= { chasWanGen 3 } chasTotalNoOfPsSlt OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This entry indicates the number of physical Power Supply slots in the chassis." ::= { chasWanGen 4 } chasTotalNoOfClSlt OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This entry indicates the number of physical Common Logic slots in the chassis." ::= { chasWanGen 5 } -- -- Wan agent status general information -- agnSDateFormat OBJECT-TYPE SYNTAX INTEGER { ddMMYYYY (1), mmDDYYYY (2), yyyyDDMM (3), yyyyMMDD (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This entry indicates the date and time format used for the agnSDateAndTimeCmd and for the alarm history report." ::= { statAgnGen 1 } agnSDateCmd OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This entry indicates the current date as it is known by the agent using its own real-time clock. The format would be as specified by the agnSDateFormat. This parameter can be set for time synchronization between the NMS and the Agent." ::= { statAgnGen 2 } agnSTimeCmd OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This entry indicates the current time as it is known by the agent using its own real-time clock. This parameter can be set for time synchronization between the NMS and the Agent." ::= { statAgnGen 3 } agnSActiveCnfg OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This entry specifies the unique identifier of the configuration, that is currently active and running." ::= { statAgnGen 4 } -- return 1 (db1) in phase I agnSEditCnfg OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This entry indicates the unique identifier of the configuration that is currently loaded into the tmp working space for manipulation and update operations. Value of 255 means no config. is under editing process." ::= { statAgnGen 5 } -- return 1 (db1) in phase I agnSLastCnfgFlipTime OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This entry indicates the Date & Time of the last flip to the current configuration at the agent." ::= { statAgnGen 6 } -- return sysUpTime in phase I agnSLastCnfgFlipCause OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This entry describes the flip's cause." ::= { statAgnGen 7 } -- In phase I return two causes: -- Power up -- Update Db agnSEditBy OBJECT-TYPE SYNTAX INTEGER { none (1), snmp (2), terCon1 (3), terCon2 (4), terInbandCon1 (5), terInbandCon2 (6), lcd (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "This entry indicates which MMI application is working on the edited config. The editing phase starts at the first modify operation and ends after an update(load) operation." ::= { statAgnGen 8 } agnSClkSrc OBJECT-TYPE SYNTAX INTEGER { master (1), fallback(2), internal(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This entry indicates the source of the system clock." ::= { statAgnGen 9 } agnSAlrStatus OBJECT-TYPE SYNTAX INTEGER { off (2), event (3), minor (4), major (5), warning (6), critical (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the alarm state in the agent level, i.e. lower level (card/port) alarms not included. critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation." ::= { statAgnGen 10 } agnSAlrStatusAll OBJECT-TYPE SYNTAX INTEGER { off (2), event (3), minor (4), major (5), warning (6), critical (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the alarm state of the entire agent, i.e. including card and port alarms status. critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation." ::= { statAgnGen 11 } agnSMaskedAlrStat OBJECT-TYPE SYNTAX INTEGER { off (2), event (3), minor (4), major (5), warning (6), critical (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the alarm state in the agent level,[ i.e. lower level (card/port) alarms not included] including Masked alarms. critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation." ::= { statAgnGen 12 } agnSMaskedAlrStatAll OBJECT-TYPE SYNTAX INTEGER { off (2), event (3), minor (4), major (5), warning (6), critical (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the alarm state of the entire agent, i.e. including card and port alarms status,including Masked alarms. critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation." ::= { statAgnGen 13 } agnSTstStatAll OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "on(3) - when there is at least one test in progress in one of the agent cards, otherwise the value will be off(2)." ::= { statAgnGen 14 } agnSAlrTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnSAlrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of agent related alarms and indications for alarms at system level." ::= { statAgnGen 15 } agnSAlrEntry OBJECT-TYPE SYNTAX AgnSAlrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { agnSAlrIdx} ::= { agnSAlrTable 1} AgnSAlrEntry ::= SEQUENCE { agnSAlrIdx Integer32, agnSAlrCodeDescription DisplayString (SIZE (0..255)), agnSAlrCode Integer32, agnSAlrSeverity INTEGER, agnSAlrState INTEGER, agnSAlrCounter Integer32, agnSAlrMask INTEGER, agnSAlrInvert INTEGER } agnSAlrIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique number to identify an entry in the alarm status table of the agent." ::= { agnSAlrEntry 1 } agnSAlrCodeDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute is a full text description of the alarm . The alarm description includes the following information: alarm code, alarm text, alarm severity, Masked or Inverted flag and counter." ::= { agnSAlrEntry 2 } agnSAlrCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A code identifying the alarm of an entry in the alarm status table at system level." ::= { agnSAlrEntry 3 } agnSAlrSeverity OBJECT-TYPE SYNTAX INTEGER { event (3), minor (4), major (5), warning (6), critical (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the alarm." ::= { agnSAlrEntry 4 } agnSAlrState OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "State of the alarm." ::= { agnSAlrEntry 5 } agnSAlrCounter OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A counter - how many times the alarm occured since last clear operation. ON and OFF Alarm will be counted separately." ::= { agnSAlrEntry 6 } agnSAlrMask OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm mask : on/off." ::= { agnSAlrEntry 7 } agnSAlrInvert OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm invert : on/off." ::= { agnSAlrEntry 8 } agnSClearAlrCmd OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to ON, enforce a clear operation on all the agent(general) events. General alarms are alarms which are not specific to a card or port. The clear operation will not be applied for masked/inverted alarms." ::= { statAgnGen 16 } agnSClearAllAlrCmd OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to ON, enforce a clear operation on all MUX alarm events at the levels of agent, slots and ports. The clear operation will not be applied for masked/inverted alarms." ::= { statAgnGen 17 } agnSSanityCheckStatus OBJECT-TYPE SYNTAX INTEGER { unknown (1), fail (2), warning (3), ok (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Upon completion of the Sanity check process on the TmpCnfg this attribute will be set to: FAIL(2) - when there is at least one error encountered and possibly some warnings. WARNING(3) - when there are only warnings. otherwise, the value will be OK(4). The value will be UNKNOWN(1) if changes were made in the TmpCnfg following the last Sanity check." ::= { statAgnGen 18 } agnSNoOfSanityCheckErr OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This entry indicates the number of errors/warnings discovered by the last SanityCheck process." ::= { statAgnGen 19 } agnSErrListTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnSErrListEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of errors and warnings found during Sanity Check process." ::= { statAgnGen 20 } agnSErrListEntry OBJECT-TYPE SYNTAX AgnSErrListEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { agnSErrIdx} ::= { agnSErrListTable 1} AgnSErrListEntry ::= SEQUENCE { agnSErrIdx Integer32, agnSErrDescription DisplayString (SIZE (0..255)) } agnSErrIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Unique number to identify an entry in the error list table. The maximum entry value cannot exceed the value of 'agnSNoOfSanityCheckErr'. " ::= { agnSErrListEntry 1} agnSErrDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute is a full text description of the sanity check error including error code, slot and port numbers related to the code ." ::= { agnSErrListEntry 2} agnSMaxNoOfCnfg OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum number of configurations that can be defined and stored in the MUX. If the mux has a large capacity, the maximum will be limited to 254." ::= { statAgnGen 21} -- return 1 (db1) in phase I agnSCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnSCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains an entry per configuration. It indicates if the configuration is valid." ::= { statAgnGen 22 } -- - in phase I only one entry agnSCnfgEntry OBJECT-TYPE SYNTAX AgnSCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { agnSEntryIdx} ::= {agnSCnfgTable 1} AgnSCnfgEntry ::= SEQUENCE { agnSEntryIdx Integer32, agnSEntryIsValid INTEGER } agnSEntryIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Unique number to identify an entry in the configuration table." ::= { agnSCnfgEntry 1} agnSEntryIsValid OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates whether the specific configuration is valid in the MUX . Value of NO indicates: no such configuration in the MUX. " ::= { agnSCnfgEntry 2} -- -- Wan agent configuration information -- agnCSanityCheckCmd OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to on(3) will initiate the process of Sanity check on the TmpCnfg. Upon completion the value will automatically be changed to off(2)." ::= { cnfgAgnGen 1 } agnCSaveCnfgIdxCmd OBJECT-TYPE SYNTAX Integer32 (1..100) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute specifies the Id of the target RealCnfg to which the TmpCnfg should be transferred. Upon set command the MUX will initiate the Sanity-Check process first. If successful, the actual transfer will be performed. If warnings are detected, the user will have to perform the command again to confirm the operation. Setting this object a second time to the same value without performing any change in the database, will cause the result: agnSSanityCheckStatus = unknown" ::= { cnfgAgnGen 2 } -- In phase I only the value 1 (Cnfg1) is valid. agnCLoadCnfgIdxCmd OBJECT-TYPE SYNTAX Integer32 (1..100) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute specifies the Id of the source Cnfg to be loaded into the TmpCnfg. Upon set operation the actual transfer will be initiated. The operation is valid only on Valid configurations (agnSEntryIsValid)" ::= { cnfgAgnGen 3 } -- In phase I only the value 1 (Cnfg1) is valid. agnCClkSrcTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnCClkSrcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "All the entries of this table are identical (have the same value) for all the configurations (1..100) except the TmpCnfg. The write operation into the Table Objects is valid only for the TmpCnfg entry." ::= { cnfgAgnGen 4} agnCClkSrcEntry OBJECT-TYPE SYNTAX AgnCClkSrcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {agnCClkCnfgIdx, agnCClkSrcIdx} ::= { agnCClkSrcTable 1} AgnCClkSrcEntry ::= SEQUENCE { agnCClkCnfgIdx Integer32, agnCClkSrcIdx Integer32, agnCClkSrcMode INTEGER, agnCClkSrcSlt INTEGER, agnCClkSrcPrt Integer32 } agnCClkCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg(1..100) being accessed and Idx 255 relates to the TmpCnfg." ::= { agnCClkSrcEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. agnCClkSrcIdx OBJECT-TYPE SYNTAX Integer32 (1..2) MAX-ACCESS read-only STATUS current DESCRIPTION "An index to the table. There are only two entries to this table. Index 1 points to the Master clock parameters and Index 2 points to the Fallback clock parameters" ::= { agnCClkSrcEntry 2} agnCClkSrcMode OBJECT-TYPE SYNTAX INTEGER { internal (1), rxClk (2), adaptive (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The source of the nodal timing." ::= { agnCClkSrcEntry 3} agnCClkSrcSlt OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-write STATUS current DESCRIPTION "This entry is valid only when we are working in rxClk mode. For an invalid entry, the return value will be '7fff'h." ::= { agnCClkSrcEntry 4} agnCClkSrcPrt OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This entry is valid only when we are working in rxClk or adaptive mode. For an invalid entry, the return value will be '7fff'h. - For rxClk mode, the values can be: exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) , exPrt7 (7) , exPrt8 (8) , exPrt9 (9) , exPrt10 (10) , exPrt11 (11) , exPrt12 (12) , notApplicable (100), inPrt1 (101) , inPrt2 (102) , inPrt3 (103) , inPrt4 (104) - For adaptive mode, the value will be the ifIndex of the selected IP Bundle." ::= { agnCClkSrcEntry 5} agnCDeleteCnfgIdxCmd OBJECT-TYPE SYNTAX Integer32 (1..100) MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute will delete the requested DB from the NVRAM ." ::= { cnfgAgnGen 5 } agnCDefaultCnfgIdxCmd OBJECT-TYPE SYNTAX Integer32 (1..100) MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute will define the desired working configuration when no conditions of the Flip DB Table are fulfilled and no Net GO command was issued. This command will be accepted only if the Configuration number exists (agnSEntryIsValid=yes)." ::= { cnfgAgnGen 6 } agnCnfgDataTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnCnfgDataEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains data about the agent configurations. The table will support only data about valid configurations of the agent." ::= { cnfgAgnGen 7} agnCnfgDataEntry OBJECT-TYPE SYNTAX AgnCnfgDataEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {agnCnfgIdx} ::= { agnCnfgDataTable 1} AgnCnfgDataEntry ::= SEQUENCE { agnCnfgIdx Integer32, agnCnfgDesc DisplayString, agnCnfgUpdDate DisplayString, agnCnfgUpdTime DisplayString, agnCnfgUpdMnger IpAddress } agnCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Idx of the agent' Cnfg the following objects refer. 255=Temporary Cnfg (Set is done only to this configuration)." ::= { agnCnfgDataEntry 1} -- Only the values 1..10, 255 are valid. agnCnfgDesc OBJECT-TYPE SYNTAX DisplayString (SIZE (0..30)) MAX-ACCESS read-write STATUS current DESCRIPTION "This object is a description of the Configuration, entered by user, to enhance Cnfg recognition." ::= { agnCnfgDataEntry 2} agnCnfgUpdDate OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the date when last update of this configuration was performed, as it is known by the agent using its own real-time clock. The format would be as specified by the agnSDateFormat. When update is performed, the agent should save the date." ::= { agnCnfgDataEntry 3 } agnCnfgUpdTime OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the time when last update of this configuration was performed, as it is known by the agent using its own real-time clock. When update is performed, the agent should save the time." ::= { agnCnfgDataEntry 4 } agnCnfgUpdMnger OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the IP Address of the Manager who performed the last update of this configuration. When update is performed, the agent should save the IP Address of the Manager who commanded the update. That will enable a manager to know if he performed the last update, or another manager did." ::= { agnCnfgDataEntry 5 } agnCnfgAlarm OBJECT IDENTIFIER ::= { cnfgAgnGen 8} agnCnfgAlrFilterWindow OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "Window of time, in seconds. During this Window, the alarms filter is performed. Same Window for all agent alarms that need filtering. Upon end of the Window, the state of the alarm is updated and a new Window starts. If no alarm needs filtering, this object's value will not be used." ::= { agnCnfgAlarm 1} agnCnfgAlrTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnCnfgAlrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table enables the user to set attributes to each alarm. Setting for a non-existing entry agnCnfgAlrMask, agnCnfgAlrInvert or agnCnfgAlrFilter to 'yes'(or yesAndSave for Mask) will add this new entry to the table. Setting for an existing entry agnCnfgAlrMask/ agnCnfgAlrInvert/agnCnfgAlrFilter (one or more) to 'no' (noAndSave for Mask) so that ALL these objects' values are 'no' , will delete this entry from the table. For agnCnfgAlrMask, only if [(last saved value=noAndSave) AND (new value is 'no' or 'noAndSave')] the object's value is considered 'no' for deleting the entry. For some products (like MP, MPH, Vmux2100) the Active Alarms are always part of the table and cannot be removed even if their Mask/Invert/Filter are No." ::= { agnCnfgAlarm 2} agnCnfgAlrEntry OBJECT-TYPE SYNTAX AgnCnfgAlrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {agnCnfgAlrCode, agnCnfgAlrSlot, agnCnfgAlrPort} ::= { agnCnfgAlrTable 1} AgnCnfgAlrEntry ::= SEQUENCE { agnCnfgAlrCode Integer32, agnCnfgAlrSlot INTEGER, agnCnfgAlrPort Integer32, agnCnfgAlrMask INTEGER, agnCnfgAlrInvert INTEGER, agnCnfgAlrFilter INTEGER, agnCnfgAlrFilterSet Integer32, agnCnfgAlrFilterReset Integer32 } agnCnfgAlrCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm code. The following attributes refer this code." ::= { agnCnfgAlrEntry 1 } agnCnfgAlrSlot OBJECT-TYPE SYNTAX INTEGER { psA (1), psB (2), clA (3), clB (4), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), io13 (17), io14 (18), io15 (19), all (200), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm slot. The following attributes apply for the alarm code and slot selected. all = the attributes apply to all slots. notApplicable = the selected alarm is for system level. For the Vmux2100 Main Board clA (3) is used." ::= { agnCnfgAlrEntry 2 } agnCnfgAlrPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm port. The following attributes apply for the alarm code,slot and port selected. 200 = all = the attributes apply to all ports of the selected slot. When selected Slot is 'all', only 'all' or 'notApplicable' are valid Port selections. notApplicable = the selected alarm is for system or card level. =255 for MP =100 for DXC - For MP: - valid cards' ports are: exPrt1(1)..exPrt16(16) inPrt1(101)..inPrt48 (148) - IP Bundles - For DXC, the port index will include the Slot, as for all DXC tables: [(IO Slot+10)&n] ; n=odd for external ports n=even for internal ports." ::= { agnCnfgAlrEntry 3 } agnCnfgAlrMask OBJECT-TYPE SYNTAX INTEGER { no (1), noAndSave (2), yes (3), yesAndSave (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "An attribute defining the desired Mask state of an alarm . no - unmask (this command is not saved in agent's common database) noAndSave - unmask ; this command is saved in agent's common database yes - mask (this command is not saved in agent's common database) yesAndSave - mask ; this command is saved in agent's common database. Commands that are not saved, will be lost upon power-up or selected card removal. " ::= { agnCnfgAlrEntry 4 } agnCnfgAlrInvert OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "An attribute defining the desired Invert state of an alarm . no - not inverted. yes - inverted. For MP, it is not applicable for alarms that are currently OFF." ::= { agnCnfgAlrEntry 5 } agnCnfgAlrFilter OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "An attribute defining if Filter is desired for the alarm . no - no filter. yes - filter activate. This filter is activated within a window of time defined by agnCnfgAlrFilterWindow. Its purpose is to avoid frequent changes of an alarm between ON/OFF states." ::= { agnCnfgAlrEntry 6 } agnCnfgAlrFilterSet OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This is a top threshold causing the alarm that passes it, to be declared Set (ON) at the end of the respective window of time. - For alarms defined by default as state alarms (minor,major) this value will be in [%]. - For alarms defined by default as events, this value will be an integer meaning how many times this event should appear at least, during the window in order to be considered ON. The maximum value will be 255. This value should be greater than the one of agnCnfgAlrFilterReset. Agents that do not support Alarms Filter, will return 0." ::= { agnCnfgAlrEntry 7 } agnCnfgAlrFilterReset OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This is a bottom threshold causing the alarm that does not pass it, to be declared Reset (ON) at the end of the respective window of time. - For alarms defined by default as state alarms (minor,major) this value will be in [%]. - For alarms defined by default as events, this value will be an integer meaning how many times this event should appear at most, during the window, in order to be considered OFF. This value should be less than the one of agnCnfgAlrFilterSet. Agents that do not support Alarms Filter, will return 0." ::= { agnCnfgAlrEntry 8 } agnCnfgAlrReportTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnCnfgAlrReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table enables the user to configure the desired Alarm Reports according to alarms severity." ::= { agnCnfgAlarm 3} agnCnfgAlrReportEntry OBJECT-TYPE SYNTAX AgnCnfgAlrReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {agnCnfgAlrReportType} ::= { agnCnfgAlrReportTable 1} AgnCnfgAlrReportEntry ::= SEQUENCE { agnCnfgAlrReportType INTEGER, agnCnfgAlrStartReportOn INTEGER, agnCnfgAlrStartReportOff INTEGER } agnCnfgAlrReportType OBJECT-TYPE SYNTAX INTEGER { trap (1), buffer (2), relay (3), --Relay 1 = R1 alrLedOn (4), --Minor LED alrLedBlink (5), --Major LED relay2 (6) --Relay 2 = R2 } MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm report type. trap - traps will be sent only for alarms having the selected On/Off severity or higher. buffer - only alarms having the selected On/Off severity and higher, will be reported to the buffer. relay - relay contact will be activated only for alarms having the selected On severity or higher. For products having 2 relays, this is the R1 Relay. alrLedOn/alrLedBlink - user should select a higher severity (ReportOn) for alrLedBlink than for alrLedOn (Blinking Led means a more severe alarm than steady ON Led). alrLedOn - MTCL-1 Alarm Led will be ON only when agnSAlrStatusAll equals the selected severity or higher, but lower severity than that selected for 'alrLedBlink'. For products having 2 LEDs, this is the Minor LED. alrLedBlink - MTCL-1 Alarm Led will Blink only when agnSAlrStatusAll equals the selected severity or higher. For products having 2 LEDs, this is the Major LED. relay2 - relay 2 contact will be activated only for alarms having the selected On severity or higher. This is the R2 Relay." ::= { agnCnfgAlrReportEntry 1 } agnCnfgAlrStartReportOn OBJECT-TYPE SYNTAX INTEGER { noReport (2), event (3), minor (4), major (5), warning (6), critical (7) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the severity from which alarms will be reported. Alarms having this severity or higher, will be reported. This object specifies the report severity only for alarms that turn to ON state. noReport - no Report at all (for any severity)." ::= { agnCnfgAlrReportEntry 2 } agnCnfgAlrStartReportOff OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), noReport (2), event (3), minor (4), major (5), warning (6), critical (7) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the severity from which alarms will be reported. Alarms having this severity or higher, will be reported. This object specifies the report severity only for alarms that turn to OFF state. notApplicable - for 'relay','alrLedOn','alrLedBlink', 'relay2' report types, in MP. noReport - no Report at all (for any severity)." ::= { agnCnfgAlrReportEntry 3 } agnCOffsetCmd OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), normal (2), u1 (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "An object defining special user request. notApplicable - is RO value for products that do not support this object. normal - nothing special u1 - user 1 - for all Voice cards, the DISPLAYED Tx and Rx Levels will have the following Offsets: - 2 Wires port: Tx Level: the base value (for 0dBm) = 0 Rx Level: the base value (for 0dBm) = -2 - 4 Wires port: Tx Level: the base value (for 0dBm) = -16 Rx Level: the base value (for 0dBm) = 7 The MIB and application DB will use the values without Offset." ::= { cnfgAgnGen 9 } --System T1/E1 Ring Table -- --This table contains all ML ports that participate in a T1/E1 Ring, --and their ML port pair. --The table indexes are Cnfg and the Primary card & port agnCT1E1RingTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnCT1E1RingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Configuration of all T1/E1 Ring ML cards and ports. The write operation into the table objects is valid only for the TmpCnfg. A Slot/Port that does not participate in the T1/E1 Ring, will not exist in this table. A ML port that exists in this table, cannot exist at the same time in the IO Redundancy table (sysCRdnTable)." ::= { cnfgAgnGen 10 } agnCT1E1RingEntry OBJECT-TYPE SYNTAX AgnCT1E1RingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An Entry in table agnCT1E1RingTable" INDEX { agnCT1E1RingCnfgIdx, agnCT1E1RingPrimeSlot, agnCT1E1RingPrimePort} ::= { agnCT1E1RingTable 1} AgnCT1E1RingEntry ::= SEQUENCE { agnCT1E1RingCnfgIdx Integer32, agnCT1E1RingPrimeSlot INTEGER, agnCT1E1RingPrimePort Integer32, agnCT1E1RingSecSlot INTEGER, agnCT1E1RingSecPort Integer32, agnCT1E1RingRecTime Integer32, agnCT1E1RingRowStatus RowStatus } agnCT1E1RingCnfgIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Idx of the Cnfg(1..255) being accessed ; Idx of 255 relates to the TmpCnfg." ::= { agnCT1E1RingEntry 1 } agnCT1E1RingPrimeSlot OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "The slot number of the Primary card of the Ring Pair." ::= { agnCT1E1RingEntry 2 } agnCT1E1RingPrimePort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The port number in the Primary Card. For external ports, the value will be as that of the port in the card. Example: external-3 -> 3 external-4 -> 4 For internal ports, the value will be 100 + the port in the card. Example: internal-1 -> 101 internal-4 -> 104 " ::= { agnCT1E1RingEntry 3 } agnCT1E1RingSecSlot OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-create STATUS current DESCRIPTION "The slot number of the Secondary card of the Ring Pair." ::= { agnCT1E1RingEntry 4 } agnCT1E1RingSecPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The port number in the Secondary Card. For external ports, the value will be as that of the port in the card. Example: external-3 -> 3 external-4 -> 4 For internal ports, the value will be 100 + the port in the card. Example: internal-1 -> 101 internal-4 -> 104 " ::= { agnCT1E1RingEntry 5 } agnCT1E1RingRecTime OBJECT-TYPE SYNTAX Integer32 (1..99) MAX-ACCESS read-create STATUS current DESCRIPTION "T1/E1 Ring Recovery Time (sec)." ::= { agnCT1E1RingEntry 6 } agnCT1E1RingRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This parameter allows NMS to create/delete entries of this table. The only possible supported RowStatus vaules are active (1) and destroy (6)." ::= { agnCT1E1RingEntry 7 } -- -- Compressed information. -- -- Specially for RadView management station -- agnCmprTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnCmprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= { cmprAgnGen 1 } agnCmprEntry OBJECT-TYPE SYNTAX AgnCmprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { agnCmprTypIdx, agnCmprCnfgIdx ,agnCmprVersion} ::= {agnCmprTable 1} AgnCmprEntry ::= SEQUENCE { agnCmprTypIdx Integer32, agnCmprCnfgIdx Integer32, agnCmprVersion Integer32, agnCmprObj OCTET STRING } agnCmprTypIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Type of the Compressed being referred." ::= { agnCmprEntry 1} agnCmprCnfgIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the configuration to which the Compressed information is related." ::= { agnCmprEntry 2} agnCmprVersion OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the version of the internal format of the Compressed data" ::= { agnCmprEntry 3} agnCmprObj OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute is the compressed information itself." ::= { agnCmprEntry 4} -- Compressed Dlci table in the Agent level -- The only way of reading this table is by the command 'GET NEXT' agnDlciCmprTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnDlciCmprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= {cmprAgnGen 2} agnDlciCmprEntry OBJECT-TYPE SYNTAX AgnDlciCmprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {agnDlciCmprCnfgIdx,agnDlciCmprVersion,agnDlciCmprDlciIdx} ::= {agnDlciCmprTable 1} AgnDlciCmprEntry ::= SEQUENCE { agnDlciCmprCnfgIdx Integer32, agnDlciCmprVersion Integer32, agnDlciCmprDlciIdx Integer32, agnDlciCmprObj OCTET STRING } agnDlciCmprCnfgIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the configuration to which the Compressed information is related." ::= { agnDlciCmprEntry 1} agnDlciCmprVersion OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the version of the internal format of the Compressed data" ::= { agnDlciCmprEntry 2} agnDlciCmprDlciIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique identifier of the Dlci, the compressed information relates to. The values are between 16 - 991." ::= { agnDlciCmprEntry 3} agnDlciCmprObj OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute is the compressed information itself." ::= { agnDlciCmprEntry 4} -- Compressed Status Alarm table at the Agent level -- The only way of reading this table is by the command 'GET NEXT' agnAlarmsCmprTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnAlarmsCmprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= {cmprAgnGen 3} agnAlarmsCmprEntry OBJECT-TYPE SYNTAX AgnAlarmsCmprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {agnAlarmsCmprVersion,agnAlarmsCmprAlarmIdx} ::= {agnAlarmsCmprTable 1} AgnAlarmsCmprEntry ::= SEQUENCE { agnAlarmsCmprVersion Integer32, agnAlarmsCmprAlarmIdx Integer32, agnAlarmsCmprObj OCTET STRING } agnAlarmsCmprVersion OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the version of the internal format of the Compressed data" ::= { agnAlarmsCmprEntry 1} agnAlarmsCmprAlarmIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique number to identify an entry in the alarm status table of the agent." ::= { agnAlarmsCmprEntry 2} agnAlarmsCmprObj OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute is the compressed information itself." ::= { agnAlarmsCmprEntry 3} -- Compressed History Alarms buffer -- The only way of reading this table is by the command 'GET NEXT' agnAlrBufCmprTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnAlrBufCmprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= {cmprAgnGen 4} agnAlrBufCmprEntry OBJECT-TYPE SYNTAX AgnAlrBufCmprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {agnAlrBufCmprVersion,agnAlrBufCmprAlarmIdx} ::= {agnAlrBufCmprTable 1} AgnAlrBufCmprEntry ::= SEQUENCE { agnAlrBufCmprVersion Integer32, agnAlrBufCmprAlarmIdx Integer32, agnAlrBufCmprObj OCTET STRING } agnAlrBufCmprVersion OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the version of the internal format of the Compressed data" ::= { agnAlrBufCmprEntry 1} agnAlrBufCmprAlarmIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique number to identify an entry in the history alarms buffer of the agent." ::= { agnAlrBufCmprEntry 2} agnAlrBufCmprObj OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute is the compressed information itself." ::= { agnAlrBufCmprEntry 3} -- Compressed Sanity Errors buffer -- The only way of reading this table is by the command 'GET NEXT' agnSCmprErrListTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnSCmprErrListEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= { cmprAgnGen 5 } agnSCmprErrListEntry OBJECT-TYPE SYNTAX AgnSCmprErrListEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {agnSCmprErrVersion,agnSCmprErrIdx} ::= { agnSCmprErrListTable 1} AgnSCmprErrListEntry ::= SEQUENCE { agnSCmprErrVersion Integer32, agnSCmprErrIdx Integer32, agnSCmprErrObj OCTET STRING } agnSCmprErrVersion OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The version of the compressed data " ::= { agnSCmprErrListEntry 1} agnSCmprErrIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Unique number to identify an entry in the errors list table. The maximum entry value cannot exceed the value of 'agnSNoOfSanityCheckErr'. " ::= { agnSCmprErrListEntry 2} agnSCmprErrObj OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute is a full text description of the error, including: error code, slot and port numbers related to the code ." ::= { agnSCmprErrListEntry 3} -- New TS Assignment compressed table, per port 01/09/98 -- The only way of reading this table is by the command 'GET NEXT' agnTsCmprTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnTsCmprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= { cmprAgnGen 6 } agnTsCmprEntry OBJECT-TYPE SYNTAX AgnTsCmprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { agnTsCmprVerIdx, agnTsCmprCnfgIdx , agnTsCmprSlotIdx, agnTsCmprPortIdx, agnTsCmprPduIdx } ::= {agnTsCmprTable 1} AgnTsCmprEntry ::= SEQUENCE { agnTsCmprVerIdx Integer32, agnTsCmprCnfgIdx Integer32, agnTsCmprSlotIdx Integer32, agnTsCmprPortIdx Integer32, agnTsCmprPduIdx Integer32, agnTsCmprData OCTET STRING } agnTsCmprVerIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the version of the internal format of the Compressed data." ::= { agnTsCmprEntry 1} agnTsCmprCnfgIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the configuration to which the Compressed information is related. 255=temporary configuration. Set can be performed only to the temporary configuration." ::= { agnTsCmprEntry 2} agnTsCmprSlotIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Slot to which the Compressed information is related. For MP-2100: IO-1..IO-12 = (5).. (16) For DXC-30 : IO-1..IO-15 = (5).. (19)." ::= { agnTsCmprEntry 3} agnTsCmprPortIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Port within the Slot, to which the Compressed information is related. For Port Index see each product's spec." ::= { agnTsCmprEntry 4} agnTsCmprPduIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the PDU index within the same port. That provides for the case when one PDU is not sufficient for all TS Assignment data of the same port." ::= { agnTsCmprEntry 5} agnTsCmprData OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "This object is the compressed information itself. It provides information about all TSs of a port." ::= { agnTsCmprEntry 6} -- Extended Compress Genearl Table with 7 indexes - 10/02/99 -- Used for: V5.1 Variant, agnXCmprTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnXCmprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= { cmprAgnGen 7 } agnXCmprEntry OBJECT-TYPE SYNTAX AgnXCmprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {agnXCmprTypIdx, agnXCmprVersion, agnXCmprIdx3,agnXCmprIdx4, agnXCmprIdx5, agnXCmprIdx6, agnXCmprIdx7} ::= {agnXCmprTable 1} AgnXCmprEntry ::= SEQUENCE { agnXCmprTypIdx Integer32, agnXCmprVersion Integer32, agnXCmprIdx3 Integer32, agnXCmprIdx4 Integer32, agnXCmprIdx5 Integer32, agnXCmprIdx6 Integer32, agnXCmprIdx7 Integer32, agnXCmprObj OCTET STRING } agnXCmprTypIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Type of the Compressed being referred. One of the types is V5.1 Variant data." ::= { agnXCmprEntry 1} agnXCmprVersion OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the version of the internal format of the Compressed data." ::= { agnXCmprEntry 2} agnXCmprIdx3 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "3rd index - can be used for any purpose according to the agnXCmprTypIdx. Example: for V5.1 Variant, this attribute indicates the configuration to which the Compressed information is related. 255=temporary configuration. Set can be performed only to the temporary configuration." ::= { agnXCmprEntry 3} agnXCmprIdx4 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "4th index - can be used for any purpose according to the agnXCmprTypIdx. Example: for V5.1 Variant,this attribute indicates a unique number of the slot position where the card is inserted. Valid values: psA(1),psB(2),clA(3),clB(4),io1(5)..io12(16); notApplicable=255." ::= { agnXCmprEntry 4} agnXCmprIdx5 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "5th index - can be used for any purpose according to the agnXCmprTypIdx. Example: for V5.1 Variant,this attribute indicates a unique identifier of the port the compressed information relates to. Valid values: exPrt1 (1) .. exPrt12 (12) , inPrt1 (101) .. inPrt48 (148)." ::= { agnXCmprEntry 5} agnXCmprIdx6 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "6th index - can be used for any purpose according to the agnXCmprTypIdx. Example: for V5.1 Variant,this attribute indicates the Variant index. Valid values are: 0..127, 255 (= temp cnfg).Set can be performed only to the temporary configuration." ::= { agnXCmprEntry 6} agnXCmprIdx7 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "7th index - can be used for any purpose according to the agnXCmprTypIdx. Example: for V5.1 Variant,this attribute is not needed. Therefore, its value will be always 255=notApplicable." ::= { agnXCmprEntry 7} agnXCmprObj OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute is the compressed information itself." ::= { agnXCmprEntry 8} -- -- Link Mapping Table for internal use -- agnLinkMapTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnLinkMapEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= { mapWanGen 1} agnLinkMapEntry OBJECT-TYPE SYNTAX AgnLinkMapEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {mapLinkId} ::= {agnLinkMapTable 1} AgnLinkMapEntry ::= SEQUENCE { mapLinkId Integer32, mapLinkSltIdx INTEGER, mapLinkPrtIdx INTEGER, mapLinkStatus INTEGER } mapLinkId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier of the link" ::= {agnLinkMapEntry 1} mapLinkSltIdx OBJECT-TYPE SYNTAX INTEGER { noConnect (2), clA (3), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries clA(3), io6(10)..io12(16) are not valid." ::= {agnLinkMapEntry 2} mapLinkPrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) , exPrt7 (7) , exPrt8 (8) , exPrt9 (9) , exPrt10 (10) , exPrt11 (11) , exPrt12 (12) , noConnect (100) , inPrt1 (101) , inPrt2 (102) , inPrt3 (103) , inPrt4 (104) , inPrt5 (105) , inPrt6 (106) , inPrt7 (107) , inPrt8 (108) , inPrt9 (109) , inPrt10 (110) , inPrt11 (111) , inPrt12 (112) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique port number. " ::= {agnLinkMapEntry 3} mapLinkStatus OBJECT-TYPE SYNTAX INTEGER { unknown(1), down(2), up(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the status of the link between the two muxes" ::= {agnLinkMapEntry 4} -- -- diverseIfWanGen - diverse NON-DS1 interfaces of WAN products -- --sonetInterface OBJECT IDENTIFIER ::= {diverseIfWanGen 2} (see radsonet.txt) --ds3Interface OBJECT IDENTIFIER ::= {diverseIfWanGen 3} (see radds3.txt) --ds1Interface OBJECT IDENTIFIER ::= {diverseIfWanGen 4} (see radds1.txt) --hdlcMibObjects OBJECT IDENTIFIER ::= {diverseIfWanGen 5} (see radhdlc.txt) --ip2If OBJECT IDENTIFIER ::= { diverseIfWanGen 7 } (see ipmux.txt) -- -- Wan alarm buffer (history) information -- alrBufTable OBJECT-TYPE SYNTAX SEQUENCE OF AlrBufEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= { alrBuffGen 1 } alrBufEntry OBJECT-TYPE SYNTAX AlrBufEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { alrBufIdx } ::= { alrBufTable 1} AlrBufEntry ::= SEQUENCE { alrBufIdx Integer32, alrBufDescription DisplayString (SIZE (0..255)) } alrBufIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique number to identify this entry" ::= { alrBufEntry 1} alrBufDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This entry is a unique text description of the alarm in the buffer. The alarm description includes the following information: alarm code, slot id, card type, channel id , alarm text, alarm status, masked flag and event counter" ::= { alrBufEntry 2} -- -- Wan Flip Data-Base parameters -- -- agnCAgendaTable : -- agnCAgendaTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnCAgendaEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table devides the week days into categories needed for DB flip consideration." ::= {agnFlipDb 1} agnCAgendaEntry OBJECT-TYPE SYNTAX AgnCAgendaEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {agnCAgendaCnfgIdx, agnCAgendaDayIdx} ::= {agnCAgendaTable 1} AgnCAgendaEntry ::= SEQUENCE { agnCAgendaCnfgIdx INTEGER, agnCAgendaDayIdx INTEGER, agnCAgendaDayCategory INTEGER } agnCAgendaCnfgIdx OBJECT-TYPE SYNTAX INTEGER { active (1), temporary (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Active or Temporary Agenda Table. Both configurations can be read but only the Temporary can be written to." ::= {agnCAgendaEntry 1} agnCAgendaDayIdx OBJECT-TYPE SYNTAX INTEGER { sunday (1), monday (2), tuesday (3), wednesday (4), thursday (5), friday (6), saturday (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Day of week" ::= {agnCAgendaEntry 2} agnCAgendaDayCategory OBJECT-TYPE SYNTAX INTEGER { fullWorkday (1), partialWorkday (2), weekend (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The Category of the Day " ::= {agnCAgendaEntry 3} -- agnCFlipNetEventsTable : -- agnCFlipNetEventsTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnCFlipNetEventsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table holds the Net Events the MUX should trace" ::= {agnFlipDb 2} agnCFlipNetEventsEntry OBJECT-TYPE SYNTAX AgnCFlipNetEventsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {agnCFlipNetEventsCnfgIdx, agnCFlipNetEventIdx} ::= {agnCFlipNetEventsTable 1} AgnCFlipNetEventsEntry ::= SEQUENCE { agnCFlipNetEventsCnfgIdx INTEGER, agnCFlipNetEventIdx Integer32, agnCFlipNetEventActive INTEGER, agnCFlipNetEventType INTEGER, agnCFlipNetEventNo Integer32, agnCFlipNetEventSlot INTEGER, agnCFlipNetEventPort Integer32, agnCFlipNetEventISD Integer32, agnCFlipNetEventOSD Integer32, agnCFlipNetEventDayType INTEGER, agnCFlipNetEventStartTime DisplayString (SIZE (5)), agnCFlipNetEventEndTime DisplayString (SIZE (5)) } agnCFlipNetEventsCnfgIdx OBJECT-TYPE SYNTAX INTEGER { active (1), temporary (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Active or Temporary Net Events Table. Both configurations can be read but only the Temporary can be written to." ::= {agnCFlipNetEventsEntry 1} agnCFlipNetEventIdx OBJECT-TYPE SYNTAX Integer32 (1..10) MAX-ACCESS read-only STATUS current DESCRIPTION "Entry within the table" ::= {agnCFlipNetEventsEntry 2} agnCFlipNetEventActive OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates if the entry is valid. In order to Add/Modify parameters of an entry, this object should be set to Yes. In order to delete an entry, this object should be Set to No." ::= {agnCFlipNetEventsEntry 3} agnCFlipNetEventType OBJECT-TYPE SYNTAX INTEGER { time (1), linkDown (2), congestion (3) -- MP3000 Only } MAX-ACCESS read-write STATUS current DESCRIPTION "The Net Event type " ::= {agnCFlipNetEventsEntry 4} agnCFlipNetEventNo OBJECT-TYPE SYNTAX Integer32 (1..512) MAX-ACCESS read-write STATUS current DESCRIPTION "The Net Event No. (Bit Index)" ::= {agnCFlipNetEventsEntry 5} agnCFlipNetEventSlot OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-write STATUS current DESCRIPTION "The slot to which the net event relates . Not applicable for time event" ::= {agnCFlipNetEventsEntry 6} agnCFlipNetEventPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The port within the relevant slot. Valid values: - extPrt1(1)..exPrt16(16) - notApplicable(100) - inPrt1(101)..inPrt48(148)" ::= {agnCFlipNetEventsEntry 7} agnCFlipNetEventISD OBJECT-TYPE SYNTAX Integer32 (1..999) MAX-ACCESS read-write STATUS current DESCRIPTION "The time in seconds since the Net Event was reported as ON until it is considered as ON. Not relevant for time events." ::= {agnCFlipNetEventsEntry 8} agnCFlipNetEventOSD OBJECT-TYPE SYNTAX Integer32 (1..999) MAX-ACCESS read-write STATUS current DESCRIPTION "The time in seconds since the net event was reported as OFF until it is considered as OFF. Not relevant for time events." ::= {agnCFlipNetEventsEntry 9} agnCFlipNetEventDayType OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), fullWorkday (2), partialWorkday (3), weekend (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The time event relates to all days defined in this category in the agnCAgendaTable. Applicable only for time event" ::= {agnCFlipNetEventsEntry 10} agnCFlipNetEventStartTime OBJECT-TYPE SYNTAX DisplayString (SIZE (5)) MAX-ACCESS read-write STATUS current DESCRIPTION "The time event will be activated at this time. The format is hh:mm." ::= {agnCFlipNetEventsEntry 11} agnCFlipNetEventEndTime OBJECT-TYPE SYNTAX DisplayString (SIZE (5)) MAX-ACCESS read-write STATUS current DESCRIPTION "The time event will be deactivated at this time. The format is hh:mm." ::= {agnCFlipNetEventsEntry 12} -- agnCFlipTable : -- agnCFlipTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnCFlipEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The DB Flip Decisions Table" ::= {agnFlipDb 3} agnCFlipEntry OBJECT-TYPE SYNTAX AgnCFlipEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {agnCFlipCnfgIdx, agnCFlipIdx} ::= {agnCFlipTable 1} AgnCFlipEntry ::= SEQUENCE { agnCFlipCnfgIdx INTEGER, agnCFlipIdx Integer32, agnCFlipActive INTEGER, agnCFlipLogicalExp DisplayString (SIZE (1..20)), agnCFlipDbNo Integer32, agnCFlipDiscardDe INTEGER } agnCFlipCnfgIdx OBJECT-TYPE SYNTAX INTEGER { active (1), temporary (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Active or Temporary Flip Decisions Table. Both configurations can be read but only the Temporary can be written to." ::= {agnCFlipEntry 1} agnCFlipIdx OBJECT-TYPE SYNTAX Integer32 (1..10) MAX-ACCESS read-only STATUS current DESCRIPTION "Entry number within the table" ::= {agnCFlipEntry 2} agnCFlipActive OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates if the entry is valid. In order to Add/Modify parameters of an entry this object should be Set to Yes. In order to delete an entry, this object should be Set to No." ::= {agnCFlipEntry 3} agnCFlipLogicalExp OBJECT-TYPE SYNTAX DisplayString (SIZE (1..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "A logical expression composed of events numbers (which were configured in the 'AgnCFlipNetEvantsTable') and logical operators ('|', '&', '!', '(', ')') between them. e.g - (1 & !2) | (121 & 230)" ::= {agnCFlipEntry 4} agnCFlipDbNo OBJECT-TYPE SYNTAX Integer32 (1..10) MAX-ACCESS read-write STATUS current DESCRIPTION "The ID of the required DB " ::= {agnCFlipEntry 5} agnCFlipDiscardDe OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates whether the Mux should start discarding all DE. (MP3000 Only)." ::= {agnCFlipEntry 6} -- Commands concerning the Flip DB agnFlipDbControls OBJECT IDENTIFIER ::= {agnFlipDb 4} agnCFlipDbSanityCheckCmd OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to on(3) will initiate the process of Sanity check on the Temp Flip Db and automatically be changed to off(2)." ::= { agnFlipDbControls 1 } agnCSaveFlipDbCmd OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to on(3) will initiate the process of Sanity check on the Temp Flip Db and if it is OK, it will save the Flip Db in the NVRAM, activating the new Flip DB . If check detects errors, the save will not be performed. Afterwards, the object's value will change automatically to off(2)." ::= { agnFlipDbControls 2 } agnCSaveNetCnfgIdxCmd OBJECT-TYPE SYNTAX Integer32 (1..10) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute specifies the Id of the target NVRAM Cnfg to which the TmpCnfg should be transferred. Upon set command the MUX will initiate the Sanity-Check process first. If successful, the actual transfer will be performed. If warnings are detected, the user will have to perform the command again to confirm the operation. Setting this object a second time to the same value without performing any change in the database, will cause the result: agnSSanityCheckStatus = unknown. This attribute doesn't cause actual Flip." ::= { agnFlipDbControls 3 } agnCSaveNetFlipDbCmd OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to on(3) will save the Temp Flip DB Into the NVRAM without actual flip." ::= { agnFlipDbControls 4 } agnCNetGoCmd OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to On will broadcast a 'GO' command to the network. When a Mux receives a 'GO' command it issues a delay for 'agnCNetDelay' seconds and then activates the DB which was pre-defined by one of the commands : 'agnCSaveNetCnfgIdxCmd' or 'agnCSaveNetFlipDbCmd'." ::= { agnFlipDbControls 5 } agnCNetDelay OBJECT-TYPE SYNTAX Integer32 (1..999) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute determines the period of time in seconds that takes for a message to be transferred over all the network. After a 'GO' command the MUX issues a delay of 'agnCNetDelay' before activating the appropriate DB. The delay will be applied only after performing agnCSaveFlipDbCmd." ::= { agnFlipDbControls 6 } agnCNetEventsBcast OBJECT-TYPE SYNTAX INTEGER { disabled(2), enabled (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object determines if the Net Events will be Broadcasted to other Muxes of the Net or not. disabled - Net Events will NOT be Broadcasted enabled - Net Events will be Broadcasted. Default=disabled. The value will be applied only after performing agnCSaveFlipDbCmd." ::= { agnFlipDbControls 7 } agnCNetEventsBcastInterval OBJECT-TYPE SYNTAX Integer32 (10..60) MAX-ACCESS read-write STATUS current DESCRIPTION "When agnCNetEventsBcast is enabled, this object determines the interval of time in seconds, between two consecutive Net Events transferred over the network. Default=40 sec. The interval will be applied only after performing agnCSaveFlipDbCmd." ::= { agnFlipDbControls 8 } -- -- agnSa = agent Stand-Alone (not HUB) specific objects -- agnSaSwchStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the status of the switches on the stand-alone unit. Each switch is represented by a bit. The status is a sum of 2**n, according to the bits: bit 0 NMS (LSB) bit 1 Terminal '1' = forces the DCE to be terminal with Rate=9600bps, Data bits=8, Stop bits=1 bit 2 Xray bit 3 SW-Load '1' = when SW is loaded bit 4 DBS Default of all bits=0 When the status of these switches is unknown, the value of this object is 255." ::= { agnSa 1 } --Decoding Table: Code vs. Description agnListDecodingTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnListDecodingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A decoding table . For each type of list, a description is given for each existing code." ::= { agnListDecoding 1 } agnListDecodingEntry OBJECT-TYPE SYNTAX AgnListDecodingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { agnListDecodingType, agnListDecodingCode } ::= { agnListDecodingTable 1} AgnListDecodingEntry ::= SEQUENCE { agnListDecodingType INTEGER, agnListDecodingCode Integer32, agnListDecodingDescription DisplayString (SIZE (0..255)), agnListDecodingDefState INTEGER, agnListDecodingSeverity INTEGER, agnListDecodingAcmRelaySlt INTEGER, agnListDecodingAcmRelayPrt INTEGER } agnListDecodingType OBJECT-TYPE SYNTAX INTEGER { alr (1), sanity (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of list the decoding data refers to. alr - Alarms list sanity - Sanity Check Error list. " ::= { agnListDecodingEntry 1} agnListDecodingCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The specific code for which decoding is needed. " ::= { agnListDecodingEntry 2} agnListDecodingDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The description fitting the specific code and type of list required. " ::= { agnListDecodingEntry 3} agnListDecodingDefState OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), event (3), minor (4), major (5), warning (6), critical (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object is applicable only for agnListDecodingType=alr. It reports the default state/severity of each alarm. User can change the severity of the alarms defined by this default via the agnListDecodingSeverity object." ::= { agnListDecodingEntry 4} agnListDecodingSeverity OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), event (3), minor (4), major (5), warning (6), critical (7) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is applicable only for agnListDecodingType=alr. It enables the user to select a severity for each alarm. The severity is set per alarm code (same for all slots/ports using this code). event - can be set only for an alarm that is defined by default as 'event'. User can change the severity of the alarms defined by default as minor or major. The severity of an event may be set to another severity, but the change will actually happen only if the event threshold is active and passed the Set/ON condition. An event alarm that passed the threshold and changed its severity, will return automatically to event severity when meeting its Reset/OFF condition." ::= { agnListDecodingEntry 5} agnListDecodingAcmRelaySlt OBJECT-TYPE SYNTAX INTEGER { none (1), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the ACM slot, desired for outbound relay (report) for the selected alarm. In the ?004 Unit the entries io6(10)..io12(16) are not valid. none - when agnListDecodingType=alr AND the selected alarm should not be reported by an ACM card. notApplicable - when agnListDecodingType=sanity OR when [agnListDecodingType=alr and there is no ACM card installed in the Mux]." ::= { agnListDecodingEntry 6} agnListDecodingAcmRelayPrt OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , notApplicable(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the ACM port within the slot, desired for outbound relay (report) for the selected alarm. notApplicable - when agnListDecodingType=sanity OR when agnListDecodingAcmRelaySlt=notApplicable." ::= { agnListDecodingEntry 7} -- Dlci Table from system point of view agnDlciTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnDlciEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= { agnSystemDlci 1} agnDlciEntry OBJECT-TYPE SYNTAX AgnDlciEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {agnDlciCnfgIdx, agnDlciLSltIdx, agnDlciLPrtIdx, agnDlciHIdx, agnDlciHSltIdx, agnDlciHPrtIdx, agnDlciLIdx } ::= { agnDlciTable 1} AgnDlciEntry ::= SEQUENCE { agnDlciCnfgIdx Integer32, agnDlciLSltIdx INTEGER, agnDlciLPrtIdx Integer32, agnDlciLIdx Integer32, agnDlciHSltIdx INTEGER, agnDlciHPrtIdx Integer32, agnDlciHIdx Integer32, agnDlciTxBc INTEGER, agnDlciTxBe INTEGER, agnDlciRxBc INTEGER, agnDlciRxBe INTEGER, agnDlciPriority Integer32, agnDlciStatus INTEGER, agnDlciSpoofing INTEGER, agnDlciFunnelEnable INTEGER, agnDlciRoutingProtocol INTEGER, agnDlciRowStatus RowStatus } agnDlciCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. " ::= { agnDlciEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. agnDlciLSltIdx OBJECT-TYPE SYNTAX INTEGER { cl(3), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), vs (254), notApplicable(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. vs=Voice Switching In the ?004 Unit the entries io6(10)..io16) are not valid. For ISDN BRI ports of MX300/30 units: io1(5) = isdn1(5) and io2(6) = isdn2(6) LSlotIdx is defined according one of the following possiblities: 1. LSlotIdx is < HSlotIdx. 2. LSlotIdx is = HSlotIdx and LPrtIdx is < HPrtIdx. 3. LSlotIdx is = HSlotIdx and LPrtIdx is = HPrtIdx but LIdx is < HIdx." ::= { agnDlciEntry 2} agnDlciLPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique external or internal port number, including linkSelector or encapsulator. 100=noConnect (for voice switching) LPrtIdx is defined according one of the following possiblities: 1. LSlotIdx is < HSlotIdx. 2. LSlotIdx is = HSlotIdx and LPrtIdx is < HPrtIdx. 3. LSlotIdx is = HSlotIdx and LPrtIdx is = HPrtIdx but LIdx is < HIdx." ::= { agnDlciEntry 3} agnDlciLIdx OBJECT-TYPE SYNTAX Integer32 (0..991) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique index for each possible used dlci(16..991). 0=notApplicable (for voice switching) LIdx is defined according one of the following possiblities: 1. LSlotIdx is < HSlotIdx. 2. LSlotIdx is = HSlotIdx and LPrtIdx is < HPrtIdx. 3. LSlotIdx is = HSlotIdx and LPrtIdx is = HPrtIdx but LIdx is < HIdx." ::= { agnDlciEntry 4} agnDlciHSltIdx OBJECT-TYPE SYNTAX INTEGER { cl (3), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position In the Mux (Agent) where the dlci is routed to. For ISDN BRI ports of MX300/30 units: io1(5) = isdn1(5) and io2(6) = isdn2(6) In the ?004 Unit the entries io6(10)..io16) are not valid" ::= { agnDlciEntry 5} agnDlciHPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port id which the dlci is routed to." ::= { agnDlciEntry 6} agnDlciHIdx OBJECT-TYPE SYNTAX Integer32 (1..991) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique internal connection dlci number which the src dlci is routed to." ::= { agnDlciEntry 7} agnDlciTxBc OBJECT-TYPE SYNTAX INTEGER { full (1), zero (2), txBc5100bps (3), txBc6400bps (4), txBc8300bps (5), txBc9600bps (6), txBc14400bps (7), txBc19200bps (8), txBc28800bps (9), txBc32000bps (10), txBc38400bps (11), txBc48000bps (12), txBc56000bps (13), txBc57600bps (14), txBc64Kbps (15), txBc128Kbps (16), txBc192Kbps (17), txBc256Kbps (18), txBc320Kbps (19), txBc384Kbps (20), txBc448Kbps (21), txBc512Kbps (22), txBc768Kbps (23), txBc896Kbps (24), txBc1024Kbps (25), txBc1152Kbps (26), txBc1280Kbps (27), txBc1344Kbps (28), txBc1472Kbps (29), txBc1600Kbps (30), txBc1728Kbps (31), txBc1856Kbps (32), txBc1920Kbps (33), txBc1984Kbps (34), txBc2048Kbps (35), txBc16000bps (36), -- Added here: No room between (7) and (8). -- For Mx 30/300 txBc112Kbps (37), txBc168Kbps (38), txBc224Kbps (39), txBc336Kbps (40), txBc672Kbps (41), txBc1536Kbps (42), txBc1792Kbps (43) } MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute indicates a unique Tx committed bandwidth on the user transmit line or at the port receive line." DEFVAL { full } ::= { agnDlciEntry 8} agnDlciTxBe OBJECT-TYPE SYNTAX INTEGER { full (1), zero (2), txBe5100bps (3), txBe6400bps (4), txBe8300bps (5), txBe9600bps (6), txBe14400bps (7), txBe19200bps (8), txBe28800bps (9), txBe32000bps (10), txBe38400bps (11), txBe48000bps (12), txBe56000bps (13), txBe57600bps (14), txBe64Kbps (15), txBe128Kbps (16), txBe192Kbps (17), txBe256Kbps (18), txBe320Kbps (19), txBe384Kbps (20), txBe448Kbps (21), txBe512Kbps (22), txBe768Kbps (23), txBe896Kbps (24), txBe1024Kbps (25), txBe1152Kbps (26), txBe1280Kbps (27), txBe1344Kbps (28), txBe1472Kbps (29), txBe1600Kbps (30), txBe1728Kbps (31), txBe1856Kbps (32), txBe1920Kbps (33), txBe1984Kbps (34), txBe2048Kbps (35), txBe16000bps (36), -- Added here: No room between (7) and (8). -- For Mx 30/300 txBe112Kbps (37), txBe168Kbps (38), txBe224Kbps (39), txBe336Kbps (40), txBe672Kbps (41), txBe1536Kbps (42), txBe1792Kbps (43) } MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute indicates a unique Tx excess bandwidth on the user transmit line or at the port receive line." DEFVAL { zero } ::= { agnDlciEntry 9} agnDlciRxBc OBJECT-TYPE SYNTAX INTEGER { full (1), zero (2), rxBc5100bps (3), rxBc6400bps (4), rxBc8300bps (5), rxBc9600bps (6), rxBc14400bps (7), rxBc19200bps (8), rxBc28800bps (9), rxBc32000bps (10), rxBc38400bps (11), rxBc48000bps (12), rxBc56000bps (13), rxBc57600bps (14), rxBc64Kbps (15), rxBc128Kbps (16), rxBc192Kbps (17), rxBc256Kbps (18), rxBc320Kbps (19), rxBc384Kbps (20), rxBc448Kbps (21), rxBc512Kbps (22), rxBc768Kbps (23), rxBc896Kbps (24), rxBc1024Kbps (25), rxBc1152Kbps (26), rxBc1280Kbps (27), rxBc1344Kbps (28), rxBc1472Kbps (29), rxBc1600Kbps (30), rxBc1728Kbps (31), rxBc1856Kbps (32), rxBc1920Kbps (33), rxBc1984Kbps (34), rxBc2048Kbps (35), rxBc16000bps (36), -- Added here: No room between (7) and (8). -- For Mx 30/300 rxBc112Kbps (37), rxBc168Kbps (38), rxBc224Kbps (39), rxBc336Kbps (40), rxBc672Kbps (41), rxBc1536Kbps (42), rxBc1792Kbps (43) } MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute indicates a unique Rx committed bandwidth on the user receive line or at the port transmit line." DEFVAL { full } ::= { agnDlciEntry 10} agnDlciRxBe OBJECT-TYPE SYNTAX INTEGER { full (1), zero (2), rxBe5100bps (3), rxBe6400bps (4), rxBe8300bps (5), rxBe9600bps (6), rxBe14400bps (7), rxBe19200bps (8), rxBe28800bps (9), rxBe32000bps (10), rxBe38400bps (11), rxBe48000bps (12), rxBe56000bps (13), rxBe57600bps (14), rxBe64Kbps (15), rxBe128Kbps (16), rxBe192Kbps (17), rxBe256Kbps (18), rxBe320Kbps (19), rxBe384Kbps (20), rxBe448Kbps (21), rxBe512Kbps (22), rxBe768Kbps (23), rxBe896Kbps (24), rxBe1024Kbps (25), rxBe1152Kbps (26), rxBe1280Kbps (27), rxBe1344Kbps (28), rxBe1472Kbps (29), rxBe1600Kbps (30), rxBe1728Kbps (31), rxBe1856Kbps (32), rxBe1920Kbps (33), rxBe1984Kbps (34), rxBe2048Kbps (35), rxBe16000bps (36), -- Added here: No room between (7) and (8). -- For Mx 30/300 rxBe112Kbps (37), rxBe168Kbps (38), rxBe224Kbps (39), rxBe336Kbps (40), rxBe672Kbps (41), rxBe1536Kbps (42), rxBe1792Kbps (43) } MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute indicates a unique Rx excess bandwidth on the user receive line or at the port transmit line." DEFVAL { zero } ::= { agnDlciEntry 11} agnDlciPriority OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute indicates a unique priority of the pcv. 1 is the lowest priority and 7 is the highest priority." ::= { agnDlciEntry 12} agnDlciStatus OBJECT-TYPE SYNTAX INTEGER { disconnected (1), connected (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the status of the pvc. The status is disconnected(1) when one of the sides is programmed as not connected" ::= { agnDlciEntry 13} agnDlciSpoofing OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object refers to sending of RIP messages: - yes : RIP messages will be sent ONLY if there is a change in the Net. - no : RIP messages will be always sent. This object is relevant only when one side of the DLCI is a CL-NMS interface. Default=no. " ::= { agnDlciEntry 14} agnDlciFunnelEnable OBJECT-TYPE SYNTAX INTEGER { disabled (2), enabled (3) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object selects Funnel activation enable/disable: - disabled: Funnel operation disabled. The agnDlciTxBe and agnDlciTxBc values are not used for funneling. - enabled : Funnel operation enabled. The agnDlciTxBe and agnDlciTxBc values are used for funneling calculations. This object is relevant only for an encapsulating DLCI. In case of a Link Selector DLCI, the agnDlciTxBe and agnDlciTxBc values are used for bandwidth of Link Selector. Default=disabled. " ::= { agnDlciEntry 15} agnDlciRoutingProtocol OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), rip (2), rip2(3), none(4) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object is relevant only when one side of the DLCI is a CL-NMS interface. It defines which Routing Protocol will be used for management via CL-NMS port. notApplicable will be used for all slots but CL. rip is a proprietary rip protocol. Default=rip. " ::= { agnDlciEntry 16} agnDlciRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute allows to create/delete a row in this table. For creating a row, the NMS should set agnRowStatus.255.id2.id3.id4.id5.id6.id7 = active(1). For destroying a row, the NMS should set: agnRowStatus.255.id2.id3.id4.id5.id6.id7 = destroy(6). Only rows with status active(1) are relevant. The only possible supported RowStatus vaules are active (1) and destroy (6)." ::= { agnDlciEntry 17} -- Voice Switching Configuration Support: agnVoiceSwitching group agnVoiceSwConfTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnVoiceSwConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "MXcess Configuration for Voice Switching." ::= { agnVoiceSwitching 1 } agnVoiceSwConfEntry OBJECT-TYPE SYNTAX AgnVoiceSwConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { agnVoiceSwConfIdx } ::= { agnVoiceSwConfTable 1} AgnVoiceSwConfEntry ::= SEQUENCE { agnVoiceSwConfIdx INTEGER, agnVoiceSwConfZoneId DisplayString, agnVoiceSwConfNodeId DisplayString, agnVoiceSwConfNoOfHops Integer32, agnVoiceSwConfSidt Integer32, agnVoiceSwConfLidt Integer32, agnVoiceSwConfDialPlan INTEGER } agnVoiceSwConfIdx OBJECT-TYPE SYNTAX INTEGER { active(1), temporary(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Active or Temporary Table. Both configurations can be read but only the Temporary can be written to." ::= { agnVoiceSwConfEntry 1} agnVoiceSwConfZoneId OBJECT-TYPE SYNTAX DisplayString(SIZE(1..2)) MAX-ACCESS read-write STATUS current DESCRIPTION "1 or 2 digits, (0-9)(1-9)." ::= { agnVoiceSwConfEntry 2} agnVoiceSwConfNodeId OBJECT-TYPE SYNTAX DisplayString(SIZE(1..3)) MAX-ACCESS read-write STATUS current DESCRIPTION "1, 2 or 3 digits, (1-9),(0-9),(0-9)." ::= { agnVoiceSwConfEntry 3} agnVoiceSwConfNoOfHops OBJECT-TYPE SYNTAX Integer32 (0..20) MAX-ACCESS read-write STATUS current DESCRIPTION "Number of hops the frame will go through the net before deciding to discard the frame (like time-to-live in IP). 0 = notApplicable Default=20 ." ::= { agnVoiceSwConfEntry 4} agnVoiceSwConfSidt OBJECT-TYPE SYNTAX Integer32 (0..30) MAX-ACCESS read-write STATUS current DESCRIPTION "SIDT: Short Inter Digit Timeout used as timer (in sec.) between digits after routing is completed. The timeout indicates end of dialing and the call can then be setup. 0 = notApplicable Default=2 sec." ::= { agnVoiceSwConfEntry 5} agnVoiceSwConfLidt OBJECT-TYPE SYNTAX Integer32 (0..30) MAX-ACCESS read-write STATUS current DESCRIPTION "LIDT: Long Inter Digit Timeout used as timer between digits before routing is completed. If no digits were dialed and LIDT expired then the user will get an error tone and the call will be disconnected. 0 = notApplicable Default=15 sec." ::= { agnVoiceSwConfEntry 6} agnVoiceSwConfDialPlan OBJECT-TYPE SYNTAX INTEGER { staticDialPlan(2), staticDialPlanPlus(3), flexDialPlan(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This is the Dialing Plan method that will be used in the Voice Switching. Static Dialing Plan - Routing is defined by the current device Zone and Node ID in the Network. Static Dialing Plan Plus - Includes the Static Dialing Plan but contains an addition of defining the number of dialed digits. Flexible Dialing Plan - Routing is defined in a flexible form. In this plan the user can configure the extension number of a local voice channel, Route a call to a remote destination and enter the Number of Digits for a specific dial prefix." ::= { agnVoiceSwConfEntry 7} agnVoiceSwConfRtTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnVoiceSwConfRtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Routing Table for Voice Switching." ::= { agnVoiceSwitching 2 } agnVoiceSwConfRtEntry OBJECT-TYPE SYNTAX AgnVoiceSwConfRtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { agnVoiceSwConfRtDbId, agnVoiceSwConfRtIdx } ::= { agnVoiceSwConfRtTable 1} AgnVoiceSwConfRtEntry ::= SEQUENCE { agnVoiceSwConfRtDbId INTEGER, agnVoiceSwConfRtIdx Integer32, agnVoiceSwConfRtDigits DisplayString, agnVoiceSwConfRtAction INTEGER, agnVoiceSwConfRtData DisplayString, agnVoiceSwConfRtSlot INTEGER, agnVoiceSwConfRtPort Integer32, agnVoiceSwConfRtDlci Integer32, agnVoiceSwConfRtRowStatus RowStatus, agnVoiceSwConfRtMaxCalls Integer32 } agnVoiceSwConfRtDbId OBJECT-TYPE SYNTAX INTEGER { active(1), temporary(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Active or Temporary Table. Both configurations can be read but only the Temporary can be written to." ::= { agnVoiceSwConfRtEntry 1 } agnVoiceSwConfRtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The Index of the row." ::= { agnVoiceSwConfRtEntry 2 } agnVoiceSwConfRtDigits OBJECT-TYPE SYNTAX DisplayString ( SIZE(1..7) ) MAX-ACCESS read-create STATUS current DESCRIPTION " Dialed digits: Series of digits 0...9, '*', '#' or '%'. The '*' and '#' can have many uses according to the user's decision. For example, they can be used as part of the Dialed Number, they exist on the phone number panel. '*' can also be used instead of a series of numbers. The '%' means any digits (wildcard) and is used without a series of digits. When the agnVoiceSwConfRtAction is del (7), the series of digits that are configured via this MIB object will be deleted from the prefix of the dialed number." ::= { agnVoiceSwConfRtEntry 3 } agnVoiceSwConfRtAction OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), zone(2), node(3), shortDialing(4), in(5), -- Internal switching hgr(6), -- Hunt Group del(7), -- Delete a prefix from the Dialed Number rep(8), -- Replace a prefix with a given string of digits pri(9), -- for ISDN bri(10),-- for ISDN numDigDP(11), -- Number of Digits user will dial according to Dialing Plan. route(12), -- Route to a Remote Destination ext(13) -- Extension to a local voice channel } MAX-ACCESS read-create STATUS current DESCRIPTION " Action that the system should perform for the digits: agnVoiceSwConfRtDigits. The action that is allowed depends on the Dialing Plan. Here is the list of the allowed actions: For Static Dialing Plan - zone, node, in, shortDialing, hgr, del, rep For Static Dialing Plan Plus - zone, node, in, shortDialing, hgr, del, rep, numDigDP For Flexible Dialing Plan - hgr, del, rep, numDigDP, route, ext" DEFVAL { notApplicable } ::= { agnVoiceSwConfRtEntry 4 } agnVoiceSwConfRtData OBJECT-TYPE SYNTAX DisplayString(SIZE(1..7)) MAX-ACCESS read-create STATUS current DESCRIPTION " This field is relevant for actions hgr(6), and rep(8), numDigDP(11) and contains the following information: For hgr - the number of the Hunt Group. For rep - the number of digits to be replaced with. For numDigDP - the number of digits collected before establishing the call. 0 indicates no defined length. In this case SIDT will be used." -- DEFVAL {"0" } ::= { agnVoiceSwConfRtEntry 5 } agnVoiceSwConfRtSlot OBJECT-TYPE SYNTAX INTEGER{ noConnect(2), cl (3), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable(255) } MAX-ACCESS read-create STATUS current DESCRIPTION " Routing Slot- Relevant for actions zone(2), node(3), shortDialing(4), route(12), ext(13)." DEFVAL { noConnect } ::= { agnVoiceSwConfRtEntry 6 } agnVoiceSwConfRtPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION " Routing Port- Relevant for actions zone(2), node(3), shortDialing(4), route(12), ext(13). 100=noConnect (for non-routing case)." DEFVAL { 0 } ::= { agnVoiceSwConfRtEntry 7 } agnVoiceSwConfRtDlci OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION " Routing DLCI- Relevant for actions zone(2), node(3), shortDialing(4), route(12), ext(13). Valid values: 0=notApplicable (for non-routing case). 1, 16..991 " DEFVAL { 15 } ::= { agnVoiceSwConfRtEntry 8 } agnVoiceSwConfRtRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION " Status of the row for creating/deleting entries in the table. The only possible supported RowStatus vaules are active (1), notInService (2), notReady(3), createAndGo(4), createAndWait(5) and destroy(6)." ::= { agnVoiceSwConfRtEntry 9 } agnVoiceSwConfRtMaxCalls OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Maximum no. of simultaneous voice calls that are allowed in the direction defined by the current entry. Default=0 (No Limit)." ::= { agnVoiceSwConfRtEntry 10} agnVoiceSwConfHGTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnVoiceSwConfHGEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of Hunt Groups." ::= { agnVoiceSwitching 5 } agnVoiceSwConfHGEntry OBJECT-TYPE SYNTAX AgnVoiceSwConfHGEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { agnVoiceSwConfHGdbIdx, agnVoiceSwConfHGIdx } ::= { agnVoiceSwConfHGTable 1} AgnVoiceSwConfHGEntry ::= SEQUENCE { agnVoiceSwConfHGdbIdx INTEGER, agnVoiceSwConfHGIdx Integer32, agnVoiceSwConfHGConnect INTEGER, agnVoiceSwConfHGExt Integer32 } agnVoiceSwConfHGdbIdx OBJECT-TYPE SYNTAX INTEGER { active(1), temporary(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Active or Temporary Table. Both configurations can be read but only the Temporary can be written to." ::= { agnVoiceSwConfHGEntry 1} agnVoiceSwConfHGIdx OBJECT-TYPE SYNTAX Integer32(1..10) MAX-ACCESS read-only STATUS current DESCRIPTION "There may be up to 10 Hunt Groups per MXcess. That's the index of the hunt group relevant to this row." ::= { agnVoiceSwConfHGEntry 2} agnVoiceSwConfHGConnect OBJECT-TYPE SYNTAX INTEGER { no(2), yes(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the hunt group should be considered in any of the mux algorithms." ::= { agnVoiceSwConfHGEntry 3} agnVoiceSwConfHGExt OBJECT-TYPE SYNTAX Integer32(0..99) MAX-ACCESS read-write STATUS current DESCRIPTION "This is the extension number of the hunt group. 0 is for not valid. The allowed range is 10 - 99." DEFVAL { 0 } ::= { agnVoiceSwConfHGEntry 4} -- -- Signaling Profiles for MP-2200 and MP-2100 -- -- Legacy Profile Table agnSigProfileTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnSigProfileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry. The table includes signaling profile parameters for Legacy Profiles." ::= { agnSigProfile 1} agnSigProfileEntry OBJECT-TYPE SYNTAX AgnSigProfileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {agnSigProfileCnfgIdx, agnSigProfileIdx, agnSigProfileRxTx} ::= { agnSigProfileTable 1} AgnSigProfileEntry ::= SEQUENCE { agnSigProfileCnfgIdx Integer32, agnSigProfileIdx Integer32, agnSigProfileRxTx INTEGER, agnSigProfileABCD OCTET STRING } agnSigProfileCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. The write operation is valid only to the TmpCnfg." ::= { agnSigProfileEntry 1} agnSigProfileIdx OBJECT-TYPE SYNTAX Integer32 (1..5) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Signaling Profile (1..5)." ::= { agnSigProfileEntry 2} agnSigProfileRxTx OBJECT-TYPE SYNTAX INTEGER { rx (1), tx (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates if the following objects refer to: Rx or Tx translation. Rx : ML->IO Tx : IO->ML ." ::= { agnSigProfileEntry 3} agnSigProfileABCD OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "This object represents 6 parameters, by 3 Octets : Busy Code-MSB nibble, - applicable only for Rx translation Idle Code- nibble, - applicable only for Rx translation D Bit Code- nibble, C Bit Code- nibble, B Bit Code- nibble, A Bit Code-LSB nibble. Each of Busy and Idle Code nibble will have the valid values: 0000 .. FFFF. Each of A,B,C,D Bit Code nibble represents: 0 hex = 0000 = 0 1 hex = 0001 = 1 2 hex = 0010 = A bit 3 hex = 0011 = B bit 4 hex = 0100 = C bit 5 hex = 0101 = D bit 6 hex = 0110 = A bit inverse 7 hex = 0111 = B bit inverse 8 hex = 1000 = C bit inverse 9 hex = 1001 = D bit inverse A-F hex - not used (invalid values) When the object is not applicable, the Octet String will have 0 bytes." ::= { agnSigProfileEntry 4} -- General Profile Table agnSigProfTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnSigProfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry. This is the general table of signaling profiles." ::= { agnSigProfile 2} agnSigProfEntry OBJECT-TYPE SYNTAX AgnSigProfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {agnSigProfCnfgIdx, agnSigProfIdx} ::= { agnSigProfTable 1} AgnSigProfEntry ::= SEQUENCE { agnSigProfCnfgIdx Integer32, agnSigProfIdx Integer32, agnSigProfName DisplayString, agnSigProfType INTEGER } agnSigProfCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. The write operation is valid only to the TmpCnfg." ::= { agnSigProfEntry 1} agnSigProfIdx OBJECT-TYPE SYNTAX Integer32 (1..5) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Signaling Profile (1..5)." ::= { agnSigProfEntry 2} agnSigProfName OBJECT-TYPE SYNTAX DisplayString(SIZE(0..12)) MAX-ACCESS read-write STATUS current DESCRIPTION "Profile Name given by user." ::= { agnSigProfEntry 3 } agnSigProfType OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), legacy (2), r2Cas (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Profile Type. legacy - usual signaling. The parameters for the Legacy Profiles are detailed in the agnSigProfileTable, above. r2Cas - R2 signaling. The parameters for the R2 Profiles are detailed in the r2 ProfileCnfg tables (belong to r2If). " ::= { agnSigProfEntry 4 } -- -- TS Assignment Table from system point of view -- -- agnTsTable OBJECT-TYPE ::= { agnSystemTs 1} -- -- For this table see tsa.txt file. -- General System Voice parameters -- systemVoiceTable OBJECT-TYPE SYNTAX SEQUENCE OF SystemVoiceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "General Parameters for voice - system level." ::= { systemVoice 1 } systemVoiceEntry OBJECT-TYPE SYNTAX SystemVoiceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { systemVoiceConfIdx } ::= { systemVoiceTable 1} SystemVoiceEntry ::= SEQUENCE { systemVoiceConfIdx Integer32, systemVoiceNationalTone INTEGER } systemVoiceConfIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed - Active or Temporary Configurations. Idx 255 relates to the temporary TmpCnfg. All configurations can be read but only the Temporary can be written to." ::= { systemVoiceEntry 1} systemVoiceNationalTone OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), usa (2), australia (3), brazil (4), canada (5), france (6), germany (7), israel (8), mexico (9), portugal (10), russia (11), spain (12), unitedKingdom (13), czech (14), china (15) } MAX-ACCESS read-write STATUS current DESCRIPTION "Tone Characteristics (Amplitude, Frequency, delays etc.). These characteristics are defined according to the country." ::= { systemVoiceEntry 2} -- -- Wan installed module status general information -- mdlSInstTable OBJECT-TYPE SYNTAX SEQUENCE OF MdlSInstEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= { statMdlGen 1 } mdlSInstEntry OBJECT-TYPE SYNTAX MdlSInstEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { mdlSInstSltIdx } ::= { mdlSInstTable 1} MdlSInstEntry ::= SEQUENCE { mdlSInstSltIdx INTEGER, mdlSInstCardType INTEGER, mdlSHwVersion DisplayString (SIZE (0..255)), mdlSSwVersion DisplayString (SIZE (0..255)), mdlSAlrStatus INTEGER, mdlSAlrStatusAll INTEGER, mdlSMaskedAlrStat INTEGER, mdlSMaskedAlrStatAll INTEGER, mdlSTstStatusAll INTEGER, mdlSClearAlrCmd INTEGER, mdlSClearAllAlrCmd INTEGER } mdlSInstSltIdx OBJECT-TYPE SYNTAX INTEGER { psA (1), psB (2), clA (3), clB (4), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "A unique number to identify a slot position in the mux. In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io(16) are not valid. For the Vmux2100 Main Board clA (3) is used." ::= { mdlSInstEntry 1} mdlSInstCardType OBJECT-TYPE SYNTAX INTEGER { -- -- General types -- unknown (1), empty (2), -- (3)..(7) are reserved ; they appear in the compress structure acm (9), --alarm module -- -- Power Supply Modules -- ps60W (10), ps100W (11), -- -- Cl Modules -- cl1 (20), clEth (21), cl2 (22), cl2Eth (23), cl3 (24), cl3Eth (25), -- -- Packet Cards of Megaplex -- mPh1 (31), mPh3 (32), mPh1T1DSU (33), mPh1T1CSU (34), mPh1E1DSU (35), mPh1E1LTU (36), -- TDM Cards mtmlFT1 (37), mtmlFE1 (38), mtmlH4E1 (39), mtmlH4E12W (40), mtmlH4T1 (41), mtmlH4T12W (42), mtHsh4E1 (43), mtHsh4E12W (44), mtHsh4T1 (45), mtHsh4T12W (46), mtmlH2E1 (47), mtmlH2E12W (48), mtmlH2T1 (49), mtmlH2T12W (50), hsh2E1 (51), hsh2E12W (52), hsh2T1 (53), hsh2T12W (54), mlIp (55), mtml4Ip (56), -- Packet Cards of Megaplex mPl6 (60), mPl3 (61), -- Vmux-2100 Main Link cards ml2E1 (68), ml4E1 (69), ml2T1 (70), ml4T1 (71), mPv4 (72), -- -- TDM Cards -- vc16A (73), vc8EandM (74), vc8Fxo (75), vc8Fxs (76), vc16EandM (77), vc16Fxo (78), vc16Fxs (79), vf3EandM (80), vf3Fxs (81), vf3Fxo (82), vfPbx (83), vfPbxT1 (84), vfPbxE1 (85), mtMlE2S (86), --Single Link mtMlE2D (87), --Dual Link mtMlF2T1 (88), mtMlF2E1 (89), mtMlT1Fiber (90), mtMlE1Fiber (91), mtMlT1FiberFb (92), mtMlE1FiberFb (93), mtmlHE1 (94), mtmlH1E1 (95), mtmlHSE1 (96), ml20 (97), mtMl4T1 (98), mtMl4E1 (99), mtMl1T1DSU (100), mtMl1T1CSU (101), mtMl1E1DSU (102), mtMl1E1LTU (103), mtMl1T1DSUfb (104), mtMl1T1CSUfb (105), mtMl1E1DSUfb (106), mtMl1E1LTUfb (107), mtMl2T1 (108), mtMl2E1 (109), ls2CcittX50 (110), ls2CcittX58 (111), ls2ATandTSdm (112), ls2ACcittX50 (113), ls2ACcittX58 (114), ls2AATandTSdm (115), ls2A2Ts (116), ls2M (117), mtMlT1 (118), mtMlE1 (119), hs2 (120), hs3 (121), hsq (122), hs703 (123), hsQM (124), hsqN (125), hs6 (126), hs12 (127), hsDp (128), hsp (129), hs4T1 (130), hs4E1 (131), hs4 (132), hsEth (133), -- Vmux-2100 Voice cards vc2E1 (136), vc4E1 (137), vc2T1 (138), vc4T1 (139), vc2EandM (140), vc2Fxs1Plar (141), vc2Fxo1 (142), vc2Fxs2 (143), vc2Fxo2 (144), vc2Fxs3 (145), vc2Fxo3 (146), vc26EandM (147), mtvc2 (148), vc2R2Fxs (149), hsu (150), mbeA (151), mbeB (152), mbeU (153), tre (154), hsuI (155), hsr (156), hss (157), hsu1 (158), ls12 (159), ls6 (160), ls6V1EandM (161), ls6V1Fxo (162), ls6V1Fxs (163), ls6V2EandM (164), ls6V2Fxo (165), ls6V2Fxs (166), ls6VfEandM (167), ls6VfFxo (168), ls6VfFxs (169), vc3EandM (170), vc3Fxo (171), vc3Fxs (172), vcPbx (173), vcPbxT1 (174), vcPbxE1 (175), vc6EandM (176), vc6Fxo (177), vc6Fxs (178), vcq (179), ls6n (180), -- -- Packet Cards of MAXcess and Hybrid -- -- High speed cards mhs1V36 (181), mhs1V35 (182), mhs1G703 (183), mhs1DDS (184), mhs3 (185), mhs1X21 (186), mhs1V24 (187), mhs4 (188), mhsE1Hs (189), mhsT1Hs (190), mhsHyE1Hs (191), -- 2 HS ports + 1 Hybrid E1 port mhsHyT1Hs (192), -- 2 HS ports + 1 Hybrid T1 port mlfHybE1Hs (193), -- Fiber Optic Hybrid: 2 HS + 1 Hybrid E1 port mlfHybT1Hs (194), -- Fiber Optic Hybrid: 2 HS + 1 Hybrid T1 port -- T1/E1 cards mhs2e1 (195), mhs2t1 (196), mhsHy2e1 (197), -- 2 Hybrid E1 ports mhsHy2t1 (198), -- 2 Hybrid T1 ports mlfHybE12 (199), -- Fiber Optic Hybrid: 2 E1 ports -- Low speed cards mls6 (200), mls3 (201), -- More T1/E1 cards mlHybAtmE1 (202), -- Hybrid ATM E1 mlHybAtmT1 (203), -- Hybrid ATM T1 mlfHybT12 (204), -- Fiber Optic Hybrid: 2 T1 ports -- Voice cards mvc8 (205), -- MVC-8 name in marketing: MVC-4N mvc8PbxE1 (206), mvc8PbxT1Dsu (207), mvc8PbxT1Csu (208), mvc8PbxE1Slave (209), mvc4 (210), mvc4PbxE1 (211), mvc4PbxT1Dsu (212), mvc4PbxT1Csu (213), mvc4PbxE1Slave (214), mvc4PbxT1Slave (215), mvc8PbxT1Slave (216), -- MVC-8 T1 Slave is here mvc8ExtAnalog (217), -- MVC-8 with 8 External ports mvcE1 (218), -- 8 External ports & 30 Internals mvcT1 (219), -- 8 External ports & 24 Internals -- ISDN for Maxcess mhsS (220), mhsU (221), mhsPriE1 (222), mhsPriT1 (223), -- CCS for Maxcess & MPH mPriE1FramerCcs (225), mPriT1FramerCcs (226), mPriE1SlaveCcs (227), mPriT1SlaveCcs (228), mDualBri (229), --Voice cards for MP vc12EandM (230), vc12Fxo (231), vc12Fxs (232), vc6aEandM (233), vc6aFxo (234), vc6aFxs (235), vc6AgFxo (236), vc6AgFxs (237), vc6a4LB (238), --ISDN cards for MP hsu12 (240), hsu6 (241), hss12 (242), hss6 (243), -- More Hybrid cards + IP cards for MPH mhsHyE1 (247), -- 1 Hybrid E1 port mhsHyT1 (248), -- 1 Hybrid T1 port mhsIp (249), -- 1 Eth port + 1 HS port mlIpHs (250), -- 1 Eth port + 3 HS ports mlHybIpE1 (251), -- 1 Eth port + 1 HS port + 1 E1 mlHybIpT1 (252), -- 1 Eth port + 1 HS port + 1 T1 -- VOIP cards for MPH & MX mvg1Lan (253), mvg2Lan (254) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the type of card installed in the specific slot position. Only PS cards are possible in the PS slots. Only CL cards are possible in the CL slots. Only IO cards are possible in the IO slots." ::= { mdlSInstEntry 2} mdlSHwVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Hardware version of the installed card in the specific slot position." ::= { mdlSInstEntry 3 } mdlSSwVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Software version of the installed card in the specific slot position." ::= {mdlSInstEntry 4} mdlSAlrStatus OBJECT-TYPE SYNTAX INTEGER { off (2), event (3), minor (4), major (5), warning (6), critical (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the alarm state at module level, i.e. lower level (port alarms) status is not included. This attribute will be set to: critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation." ::= { mdlSInstEntry 5 } mdlSAlrStatusAll OBJECT-TYPE SYNTAX INTEGER { off (2), event (3), minor (4), major (5), warning (6), critical (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the alarm state in the module-all level, i.e. lower level (port alarms) included. This attribute will be set to: critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation." ::= { mdlSInstEntry 6 } mdlSMaskedAlrStat OBJECT-TYPE SYNTAX INTEGER { off (2), event (3), minor (4), major (5), warning (6), critical (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the alarm state at module level, [i.e. lower level (port alarms) status is not included],including Masked alarms. This attribute will be set to: critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation." ::= { mdlSInstEntry 7 } mdlSMaskedAlrStatAll OBJECT-TYPE SYNTAX INTEGER { off (2), event (3), minor (4), major (5), warning (6), critical (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the alarm state in the module-all level, i.e. lower level (port alarms) included, including Masked alarms. This attribute will be set to: critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation." ::= { mdlSInstEntry 8 } mdlSTstStatusAll OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute will be set to on(3) when there is at least one test in progress on a channel of the card, otherwise the value will be off(2)." ::= { mdlSInstEntry 9 } mdlSClearAlrCmd OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this command to ON, enforces a clear of all the alarms in the given slot, excluding alarms of port level. The clear operation will not be applied for masked/inverted alarms." ::= { mdlSInstEntry 10 } mdlSClearAllAlrCmd OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this command to ON, enforces a clear of all the alarms in the given slot, including all its ports alarms. The clear operation will not be applied for masked/inverted alarms." ::= { mdlSInstEntry 11 } mdlSAlrTable OBJECT-TYPE SYNTAX SEQUENCE OF MdlSAlrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The list of card agent alarms ; includes also an alarm indicating existence of alarms on its ports if there are any." ::= { statMdlGen 2 } mdlSAlrEntry OBJECT-TYPE SYNTAX MdlSAlrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {mdlSAlrSltIdx , mdlSAlrIdx} ::= { mdlSAlrTable 1} MdlSAlrEntry ::= SEQUENCE { mdlSAlrSltIdx INTEGER, mdlSAlrIdx Integer32, mdlSAlrCodeDescription DisplayString (SIZE (0..255)), mdlSAlrCode Integer32, mdlSAlrSeverity INTEGER, mdlSAlrState INTEGER, mdlSAlrCounter Integer32, mdlSAlrMask INTEGER, mdlSAlrInvert INTEGER } mdlSAlrIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique number to identify an entry in the alarm status table. Users should use the get next function to read this table because the indexes are not consecutive." ::= { mdlSAlrEntry 1} mdlSAlrSltIdx OBJECT-TYPE SYNTAX INTEGER { psA (1), psB (2), clA (3), clB (4), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the desired slot position. In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io12(16) are not valid. For the Vmux2100 Main Board clA (3) is used." ::= { mdlSAlrEntry 2} mdlSAlrCodeDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute is a full text description of the alarm . The alarm description includes the following information: alarm code, alarm text, alarm severity, Masked or Inverted flag and counter." ::= { mdlSAlrEntry 3} mdlSAlrCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A code identifying the alarm of an entry in the alarm status table at card level." ::= { mdlSAlrEntry 4 } mdlSAlrSeverity OBJECT-TYPE SYNTAX INTEGER { event (3), minor (4), major (5), warning (6), critical (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the alarm." ::= { mdlSAlrEntry 5 } mdlSAlrState OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "State of the alarm." ::= { mdlSAlrEntry 6 } mdlSAlrCounter OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A counter - how many times the alarm occured since last clear operation. ON and OFF Alarm will be counted separately." ::= { mdlSAlrEntry 7 } mdlSAlrMask OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm mask : on/off." ::= { mdlSAlrEntry 8 } mdlSAlrInvert OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm invert : on/off." ::= { mdlSAlrEntry 9 } -- -- Wan module configuration information -- mdlCPrgTable OBJECT-TYPE SYNTAX SEQUENCE OF MdlCPrgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= { cnfgMdlGen 1 } mdlCPrgEntry OBJECT-TYPE SYNTAX MdlCPrgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { mdlCCnfgIdx, mdlCSltIdx } ::= { mdlCPrgTable 1} MdlCPrgEntry ::= SEQUENCE { mdlCCnfgIdx Integer32, mdlCSltIdx INTEGER, mdlCPrgCardType INTEGER, mdlCNoOfExternPrt Integer32, -- RO mdlCNoOfInternPrt Integer32, -- RO mdlCWorkMode INTEGER } mdlCCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg(1..100) being referred. Value 255 specifies the TmpCnfg " ::= { mdlCPrgEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. mdlCSltIdx OBJECT-TYPE SYNTAX INTEGER { psA (1), psB (2), clA (3), clB (4), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique number of the slot position where the card is inserted. In the ?004 Unit the entries psB(2),clB(4),io6(10)..io(16) are not valid." ::= { mdlCPrgEntry 2} mdlCPrgCardType OBJECT-TYPE SYNTAX INTEGER { -- -- General types -- unknown (1), empty (2), -- (3)..(7) are reserved ; they appear in the compress structure acm (9), --alarm module -- -- Power Supply Modules -- ps48x60W (10), ps48x100W (11), ps110x60W (12), ps110x100W (13), ps220x60W (14), ps220x100W (15), ps180W (16), -- -- Cl Modules -- cl1 (20), clEth (21), cl2 (22), cl2Eth (23), cl3 (24), cl3Eth (25), -- -- Packet Cards of Megaplex -- mPh1 (31), mPh3 (32), mPh1T1DSU (33), mPh1T1CSU (34), mPh1E1DSU (35), mPh1E1LTU (36), -- TDM Cards mtmlFT1 (37), mtmlFE1 (38), mtmlH4E1 (39), mtmlH4E12W (40), mtmlH4T1 (41), mtmlH4T12W (42), mtHsh4E1 (43), mtHsh4E12W (44), mtHsh4T1 (45), mtHsh4T12W (46), mtmlH2E1 (47), mtmlH2E12W (48), mtmlH2T1 (49), mtmlH2T12W (50), hsh2E1 (51), hsh2E12W (52), hsh2T1 (53), hsh2T12W (54), mlIp (55), mtml4Ip (56), -- Packet Cards of Megaplex mPl6 (60), -- mPl3 (61), -- Vmux-2100 Main Link cards ml2E1 (68), ml4E1 (69), ml2T1 (70), ml4T1 (71), -- mPv4 (72), -- -- TDM Cards -- vc16A (73), vc8EandM (74), vc8Fxo (75), vc8Fxs (76), vc16EandM (77), vc16Fxo (78), vc16Fxs (79), vf3EandM (80), vf3Fxs (81), vf3Fxo (82), vfPbx (83), vfPbxT1 (84), vfPbxE1 (85), mtMlE2S (86), --Single Link mtMlE2D (87), --Dual Link mtMlF2T1 (88), mtMlF2E1 (89), mtMlT1Fiber (90), mtMlE1Fiber (91), mtMlT1FiberFb (92), mtMlE1FiberFb (93), mtmlHE1 (94), mtmlH1E1 (95), mtmlHSE1 (96), ml20 (97), mtMl4T1 (98), mtMl4E1 (99), mtMl1T1DSU (100), mtMl1T1CSU (101), mtMl1E1DSU (102), mtMl1E1LTU (103), mtMl1T1DSUfb (104), mtMl1T1CSUfb (105), mtMl1E1DSUfb (106), mtMl1E1LTUfb (107), mtMl2T1 (108), mtMl2E1 (109), ls2CcittX50 (110), ls2CcittX58 (111), ls2ATandTSdm (112), ls2ACcittX50 (113), ls2ACcittX58 (114), ls2AATandTSdm (115), ls2A2Ts (116), ls2M (117), mtMlT1 (118), mtMlE1 (119), hs2 (120), hs3 (121), hsq (122), hs703 (123), hsQM (124), hsqN (125), hs6 (126), hs12 (127), hsDp (128), hsp (129), hs4T1 (130), hs4E1 (131), hsEth (133), vc2E1 (136), vc4E1 (137), vc2T1 (138), vc4T1 (139), vc2EandM (140), vc2Fxs1Plar (141), vc2Fxo1 (142), vc2Fxs2 (143), vc2Fxo2 (144), vc2Fxs3 (145), vc2Fxo3 (146), vc26EandM (147), mtvc2 (148), vc2R2Fxs (149), hsu (150), mbeA (151), mbeB (152), mbeU (153), tre (154), hsuI (155), hsr (156), hss (157), hsu1 (158), ls12 (159), ls6 (160), ls6V1EandM (161), ls6V1Fxo (162), ls6V1Fxs (163), ls6V2EandM (164), ls6V2Fxo (165), ls6V2Fxs (166), ls6VfEandM (167), ls6VfFxo (168), ls6VfFxs (169), vc3EandM (170), vc3Fxo (171), vc3Fxs (172), vcPbx (173), vcPbxT1 (174), vcPbxE1 (175), vc6EandM (176), vc6Fxo (177), vc6Fxs (178), vcq (179), ls6n (180), -- -- Packet Cards of Maxcess and Hybrid -- -- High speed cards mhs1V36 (181), mhs1V35 (182), mhs1G703 (183), mhs1DDS (184), mhs3 (185), mhs1X21 (186), mhs1V24 (187), mhs4 (188), mhsE1Hs (189), mhsT1Hs (190), mhsHyE1Hs (191), -- 2 HS ports + 1 Hybrid E1 port mhsHyT1Hs (192), -- 2 HS ports + 1 Hybrid T1 port mlfHybE1Hs (193), -- Fiber Optic Hybrid: 2 HS + 1 Hybrid E1 port mlfHybT1Hs (194), -- Fiber Optic Hybrid: 2 HS + 1 Hybrid T1 port -- T1/E1 cards mhs2e1 (195), mhs2t1 (196), mhsHy2e1 (197), -- 2 Hybrid E1 ports mhsHy2t1 (198), -- 2 Hybrid T1 ports mlfHybE12 (199), -- Fiber Optic Hybrid: 2 E1 ports -- Low speed cards mls6 (200), mls3 (201), -- More T1/E1 cards mlHybAtmE1 (202), -- Hybrid ATM E1 mlHybAtmT1 (203), -- Hybrid ATM T1 mlfHybT12 (204), -- Fiber Optic Hybrid: 2 T1 ports -- Voice cards mvc8 (205), -- MVC-8 name in marketing: MVC-4N mvc8PbxE1 (206), mvc8PbxT1Dsu (207), mvc8PbxT1Csu (208), mvc8PbxE1Slave (209), mvc4 (210), mvc4PbxE1 (211), mvc4PbxT1Dsu (212), mvc4PbxT1Csu (213), mvc4PbxE1Slave (214), mvc4PbxT1Slave (215), mvc8PbxT1Slave (216), -- MVC-8 T1 Slave is here mvc8ExtAnalog (217), -- MVC-8 with 8 External ports mvcE1 (218), -- 8 External ports & 30 Internals mvcT1 (219), -- 8 External ports & 24 Internals -- ISDN for Maxcess mhsS (220), mhsU (221), mhsPriE1 (222), mhsPriT1 (223), -- CCS for Maxcess & MPH mPriE1FramerCcs (225), mPriT1FramerCcs (226), mpriE1SlaveCcs (227), mpriT1SlaveCcs (228), mDualBri (229), --Voice cards for MP vc12EandM (230), vc12Fxo (231), vc12Fxs (232), vc6aEandM (233), vc6aFxo (234), vc6aFxs (235), vc6AgFxo (236), vc6AgFxs (237), vc6a4LB (238), --ISDN cards for MP hsu12 (240), hsu6 (241), hss12 (242), hss6 (243), -- More Hybrid cards + IP cards for MPH mhsHyE1 (247), -- 1 Hybrid E1 port mhsHyT1 (248), -- 1 Hybrid T1 port mhsIp (249), -- 1 Eth port + 1 HS port mlIpHs (250), -- 1 Eth port + 3 HS ports mlHybIpE1 (251), -- 1 Eth port + 1 HS port + 1 E1 mlHybIpT1 (252), -- 1 Eth port + 1 HS port + 1 T1 -- VOIP cards for MPH & MX mvg1Lan (253), mvg2Lan (254) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the type of card assigned to the specific slot in the common configuration. This object is identical in all the configurations (1..100). Only the TmpCnf(255) may have different value. The write operation is valid only to the TmpCnfg entry." ::= { mdlCPrgEntry 3} mdlCNoOfExternPrt OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of external ports in the programmed card of the specific slot position" ::= { mdlCPrgEntry 4} mdlCNoOfInternPrt OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of internal ports in the programmed card of the specific slot position." ::= { mdlCPrgEntry 5} mdlCWorkMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), standAlone (2), integrated (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Working mode of the card. The user may configure the card to work in a stand alone mode or integrated with the device. Example for use in MHS-IP cards: - standAlone - in this mode, the router works so that data is received via the LAN (Eth) port and is transmitted via the WAN (HS) external port without going through the MPH device. - integrated - in this mode, the router works so that it is integrated in the MPH and routes DLCIs into the device." ::= { mdlCPrgEntry 6} -- -- Compressed information. -- -- Specially for RadView management station -- mdlCmprTable OBJECT-TYPE SYNTAX SEQUENCE OF MdlCmprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= { cmprMdlGen 1 } mdlCmprEntry OBJECT-TYPE SYNTAX MdlCmprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { mdlCmprTypIdx, mdlCmprCnfgIdx ,mdlCmprVersion,mdlCmprSltIdx } ::= {mdlCmprTable 1} MdlCmprEntry ::= SEQUENCE { mdlCmprTypIdx Integer32, mdlCmprCnfgIdx Integer32, mdlCmprVersion Integer32, mdlCmprSltIdx INTEGER, mdlCmprObj OCTET STRING } mdlCmprTypIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Type of the Compressed being referred." ::= { mdlCmprEntry 1} mdlCmprCnfgIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the configuration to which the Compressed information is related." ::= { mdlCmprEntry 2} mdlCmprVersion OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the version of the internal format of the Compressed data" ::= { mdlCmprEntry 3} mdlCmprSltIdx OBJECT-TYPE SYNTAX INTEGER { psA (1), psB (2), clA (3), clB (4), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique number of the slot position where the card is inserted. In the ?004 Unit the entries psB(2),clB(4),io6(10)..io(16) are not valid." ::= { mdlCmprEntry 4} mdlCmprObj OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute is the compressed information itself." ::= { mdlCmprEntry 5} -- Compressed Alarm table at Card level -- The only way of reading this table is by the command 'GET NEXT' mdlAlarmsCmprTable OBJECT-TYPE SYNTAX SEQUENCE OF MdlAlarmsCmprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= {cmprMdlGen 2} mdlAlarmsCmprEntry OBJECT-TYPE SYNTAX MdlAlarmsCmprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {mdlAlarmsCmprVersion, mdlAlarmsCmprAlarmSlot,mdlAlarmsCmprAlarmIdx} ::= {mdlAlarmsCmprTable 1} MdlAlarmsCmprEntry ::= SEQUENCE { mdlAlarmsCmprVersion Integer32, mdlAlarmsCmprAlarmSlot Integer32, mdlAlarmsCmprAlarmIdx Integer32, mdlAlarmsCmprObj OCTET STRING } mdlAlarmsCmprVersion OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the version of the internal format of the Compressed data" ::= { mdlAlarmsCmprEntry 1} mdlAlarmsCmprAlarmSlot OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the desired slot position. In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io(16) are not valid." ::= { mdlAlarmsCmprEntry 2} mdlAlarmsCmprAlarmIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique number to identify an entry in the alarm status table of the agent." ::= { mdlAlarmsCmprEntry 3} mdlAlarmsCmprObj OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute is the compressed information itself." ::= { mdlAlarmsCmprEntry 4} -- -- Wan port status general information -- prtSInstTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtSInstEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= { statPrtGen 1 } prtSInstEntry OBJECT-TYPE SYNTAX PrtSInstEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { prtSInstSltIdx, prtSInstPrtIdx } ::= { prtSInstTable 1} PrtSInstEntry ::= SEQUENCE { prtSInstSltIdx INTEGER, prtSInstPrtIdx Integer32, prtSInstPrtType INTEGER, prtSInstIfIndex Integer32, prtSActiveStatus INTEGER, prtSAlrStatus INTEGER, prtSMaskedAlrStat INTEGER, prtSClearAlrCmd INTEGER, prtSTestMask Integer32, -- prtSTstStatus INTEGER, prtSTstCmd INTEGER, prtSTstDuration Integer32, prtSBertClrCmd INTEGER, prtSBertTstRslt Integer32, prtSInterfaceType DisplayString (SIZE (0..255)), prtSParamStatus OCTET STRING } prtSInstSltIdx OBJECT-TYPE SYNTAX INTEGER { clA (3), clB (4), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique number to identify the slot where the card is inserted. In the ?004 Unit the entries io6(10)..io(16) are not valid. For the Vmux2100 Main Board clA (3) is used." ::= { prtSInstEntry 1} prtSInstPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique number to identify a port in a specific card. The valid ports depend on the installed card: the valid external ports (interfaces) are (1..mdlCNoOfExternPrt) if any, and the valid internal ports are (101..100+mdlCNoOfInternPrt) if any. Generally: exPrt1 (1) .. exPrt16 (16),inPrt1 (101) .. inPrt48 (148) For the Vmux-2100 device: This index will have values of 1...4 for the physical ports & values of ifIndex for the bundles. " ::= { prtSInstEntry 2} prtSInstPrtType OBJECT-TYPE SYNTAX INTEGER { external (2), internal (3), highSpeedV35 (4), highSpeedV24 (5), highSpeedV36 (6), highSpeedX21 (7), highSpeedG703 (8), highSpeedDDS (9), lowSpeed (10), voice (11), cl (12), isdns (13), isdnu (14), ethernet (15), voiceS0 (16), voiceU (17), voiceQsigS (18), voiceQsigU (19) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute describes the type of the designated port. In MX 3000 only external & internal options are used. All the other options are only for MX 30/300 which need special handling. In order to support interface types in MX 3000, return an ascii string for prtSInterfaceType in this table or support the general RAD value of physicalConnector. External port - is a port with a physical connector. Internal port - might be of two types: a) A composite port which collects a few external ports data into a common bandwidth (usually routed through DS1 link) b) A port which gets only part of the external ports (usually a few DS0's) The following types are used when all ports are external/ internal and the connector/interface type is necessary (for example, stand-alone units): High Speed port types Low Speed port types Voice port types, CL port types. ISDN Voice in MX 30/300 Phase 4: voiceS0 (16), voiceU (17) should be used. ISDN Voice in MX 30/300 Phase 5: voiceQsigS(18), voiceQsigU (19) should be used." ::= { prtSInstEntry 3} prtSInstIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the unique interface number assigned to the port. The specific interface of this attribute is the same as the interface identified by the value of ifindex in MIB-II.If there is no interface for the specific prtIdx the value will be '7fffffff'h." ::= { prtSInstEntry 4} prtSActiveStatus OBJECT-TYPE SYNTAX INTEGER { unknown (1), notUsed (2), offLine (3), onLine (4), offLineRedundancy (5), onLineRedundancy (6) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute describes the activity status of the port. unknown(1) indicates that the information is not supported. notUsed(2) indicates that the ch is not connected according to the active config. offLine(3) indicates that the ch is down (not working) because of any problem. onLine(4) indicates that the ch is up (working) offLineRedundancy(5) indicates that the ch is down, because it is redundant port. onLineRedundancy(6) indicates that the ch is up, and it is the active link" ::= { prtSInstEntry 5} prtSAlrStatus OBJECT-TYPE SYNTAX INTEGER { off (2), event (3), minor (4), major (5), warning (6), critical (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the alarm state in the port(ch) agent level. This attribute will be set to: critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation." ::= { prtSInstEntry 6} prtSMaskedAlrStat OBJECT-TYPE SYNTAX INTEGER { off (2), event (3), minor (4), major (5), warning (6), critical (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the alarm state in the port(ch) agent level, including Masked alarms. This attribute will be set to: critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation." ::= {prtSInstEntry 7} prtSClearAlrCmd OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to on(3) enforces a clear operation of the alarm status events in the given port. The clear operation will not be applied for masked/inverted alarms." ::= { prtSInstEntry 8} prtSTestMask OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a mask which indicates which tests from the 'prtSTstCmd' list are allowed for the requested port. If a specific test is allowed, its respective bit will be SET in the mask : TEST BIT ----------- --- local-loop 1 remote-loop 2 loc-and-rem-main-loops 3 remote-analog-loop 4 remote-digital-loop 5 rem-loop-on-ext-unit 6 bert 7 tone-injection 8 dlci local-loop 9 all dlci local-loop 10 dlci remote-loop 11 all dlci remote-loop 12 bert-and-rem-loop-on-rem-unit 13 rem-loop-on-rem-unit 14 block 15 backward-tone-inject 16 llb 17 rlb 18 ft1Enable 21 lbbd 22 --for 2B+D lb1 23 --for B1 lb2 24 --for B2 llb-on-rem-unit 25 bert-on-rem-unit 26 bert-on-rem-and-llb-on-rem-unit 27 local-and-bert-on-rem-unit 28 local-loop-on-rem-unit 29 localBert 30 --towards IO ports test-per-TS 31 e.g : If the return value is 3 -> 0000000000000011 -> Bits 1 & 2 are set -> the allowed tests are : local-loop remote-loop " ::= { prtSInstEntry 9} -- prtSTstStatus OBJECT-TYPE -- SYNTAX INTEGER -- { -- off(2), -- on (3) -- } -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- "This attribute will be set to on(3) when there is at least -- one test in progress in the port, otherwise the value -- will be off(2)." -- ::= { prtSInstEntry 10} -- prtSTstCmd OBJECT-TYPE SYNTAX INTEGER { none (1), localLoop (2), remoteLoop (3), locAndRemMainLoops (4), remoteAnalogLoop (5), remoteDigitalLoop (6), remLoopOnExtUnit (7), bert (8), toneInjection (9), dlciLocalLoop (10), allDlciLocalLoop (11), dlciRemoteLoop (12), allDlciRemoteLoop (13), extInitLocalLoop (14), bertAndRemLoopOnRemUnit (15), remLoopOnRemUnit (16), block (17), backwardToneInject (18), llb (19), rlb (20), ft1Enable (21), lbbd (22), --for 2B+D lb1 (23), --for B1 lb2 (24), --for B2 llbOnRemUnit (25), bertOnRemUnit (26), bertOnRemAndLlbOnRemUnit (27), localAndBertOnRemUnit(28), localLoopOnRemUnit (29), localBert (30), testPerTS (31) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to any of the above values will initiate a test on the specific port if the operation is legal. If the operation is not legal, the mux will ignore the operation. testPerTS(31) - when this test is selected, the selection of tests for each TS is done via the prtExPh1MlTsTest object. If a test time out is needed, the test will be set with a default timeout of 2 minutes until the user will set the parameter 'prtSTstDuration' to the required time out. If no time out is needed , the test will be set with infinite timeout until the user will set the parameter 'prtSTstDuration' to the required time out." ::= { prtSInstEntry 10} prtSTstDuration OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the maximum duration of executing a test on the specific port. This entry applies to all the test operations. The resolution will be a minute, and the maximum duration is limited to 30 minutes . A zero value specifies no time limitation. When the test isn't active, the agent initiates this object to 2 when the duration is needed and to 0 if its not required. The user should set this parameter after setting the 'prtSTstCmd' parameter." ::= { prtSInstEntry 11} prtSBertClrCmd OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute initiates bert count clear operation. It is valid only when bert test is active on the specific port." ::= { prtSInstEntry 12} prtSBertTstRslt OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the number of Bit Error Rate indicated during the BERT operation. It is valid only when bert test is active on the specific port." ::= { prtSInstEntry 13} prtSInterfaceType OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique HW interface type of the selected port." ::= { prtSInstEntry 14} prtSParamStatus OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates Status of parameters specific to the selected port. - For a port that has no special status or is supported by prtSExHsfStatTable - 1 Octet: 00hex - For VC-6, VC-6A, VC-6AG, VC-6A/4LB, VC-12, VC-12/6, external ports - 1 Octet : Bit 7 (MSB)..Bit 2 = 0 (NA) Bit 1: Tx Signaling '1'=On ; '0'=Off Bit 0 (LSB): Rx Signaling '1'=On ; '0'=Off - For VC-2/R2(FXS) external ports - 1 Octet : Bit - 7 6 5 4 3 2 1 0 |_| |_________| Call Call State Direction Bit 7 (MSB) and Bit 6 : Call Direction 00 - Incoming 01 - Outgoing Bit 5..Bit 0: Call State 000000 - Idle 000001 - Seized 000010 - Both-Way Conflict 000011 - Seizure Ack 000100 - Answered 000101 - Clear Backward 000110 - Clear Forward 000111 - Blocked 001000 - Fault 001001 - Fault 3 001010 - Fault 4 001011 - Fault 5 001100 - Fault 6 001101 - Fault 7 - For ML-20 external port - 3 Octets : - 1 MS Octet will represent the Real Rate used: Bit - 7 6 5 4 3 2 1 0 |___| |_______| spare Rate Valid values: 0..31, meaning 0..31x64Kbps Invalid values: 32..255. - 2 LS Octets will represent the Status of 7 Control Signals: Signal - --- CTS DSR DCD RJ TM DTR RTS Bit - 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Octet - 2 3 (LS) '---' will always have the value 00 Rest of the Signals (2 bits each) can have the following values: 00=NA ; 01=unused ; 10=Off ; 11=On - For ML-H/E1, ML-H/1/E1, ML-H/S/E1 internal port - 1 Octet Bit - 7 6 5 4 3 2 1 0 |___________| spare Mode of Operation Mode of Operation: '1'=Central ; '0'=Remote - For ACM external port - 1 Octet Bit - 7 6 5 4 3 2 1 0 |_________| spare Alarm State Alarm State: according to bits 1,0: 00=NA ; 01=unused ; 10=Off ; 11=On - For HS-U/1 external port - 1 Octet Bit 7 6 5 4 3 2 1 0 LSB |________| |__| |__| spare modem sync modem: 00 = other sync: 00 = not sync 01 = unknown 01 = sync 10 = ASMi-31/2 10 = reserved 11 = reserved 11 = reserved - For MTML-2 external ports, MTML-E2 internal ports - 1 Octet : Bit 7 6 5 4 3 2 1 0 LSB | BERT State BERT State (Bit 0): 0 = OFF (BERT is not running on this port or any of its TSs/Bits) 1 = ON (BERT is running on this port OR on one of its TSs/Bits)" ::= { prtSInstEntry 15} prtSAlrTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtSAlrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The list of port agent alarms." ::= { statPrtGen 2 } prtSAlrEntry OBJECT-TYPE SYNTAX PrtSAlrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { prtSAlrSltIdx, prtSAlrPrtIdx, prtSAlrIdx} ::= { prtSAlrTable 1} PrtSAlrEntry ::= SEQUENCE { prtSAlrSltIdx INTEGER, prtSAlrPrtIdx Integer32, prtSAlrIdx Integer32, prtSAlrCodeDescription DisplayString (SIZE (0..255)), prtSAlrCode Integer32, prtSAlrSeverity INTEGER, prtSAlrState INTEGER, prtSAlrCounter Integer32, prtSAlrMask INTEGER, prtSAlrInvert INTEGER } prtSAlrIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique number to identify an entry in the alarm status table. Users should use the get next function to read this table because the indexes are not consecutive" ::= { prtSAlrEntry 1} prtSAlrSltIdx OBJECT-TYPE SYNTAX INTEGER { psA (1), psB (2), clA (3), clB (4), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique identifier of the slot where the card is inserted. In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io12(16) are not valid. For the Vmux2100 Main Board clA (3) is used." ::= { prtSAlrEntry 2} prtSAlrPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique identifier of the port the alarm applies to. All the values are valid. No alarms exist for a port which does not exist. Valid values: exPrt1 (1) .. exPrt16 (16) , inPrt1 (101) .. inPrt48 (148), IP Bundles." ::= { prtSAlrEntry 3} prtSAlrCodeDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute is a full text description of the alarm. The alarm description includes the following information: alarm code, alarm text, alarm severity, Masked or Inverted flag and counter." ::= { prtSAlrEntry 4} prtSAlrCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A code identifying the alarm of an entry in the alarm status table at port level." ::= { prtSAlrEntry 5 } prtSAlrSeverity OBJECT-TYPE SYNTAX INTEGER { event (3), minor (4), major (5), warning (6), critical (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the alarm." ::= { prtSAlrEntry 6 } prtSAlrState OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "State of the alarm." ::= { prtSAlrEntry 7 } prtSAlrCounter OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A counter - how many times the alarm occured since last clear operation. ON and OFF Alarm will be counted separately." ::= { prtSAlrEntry 8 } prtSAlrMask OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm mask : on/off." ::= { prtSAlrEntry 9 } prtSAlrInvert OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm invert : on/off." ::= { prtSAlrEntry 10 } -- -- Statistics of Ports -- statisPrtGen OBJECT IDENTIFIER ::= {statPrtGen 3} prtFrStatis OBJECT IDENTIFIER ::= {statisPrtGen 1} prtCrStatis OBJECT IDENTIFIER ::= {statisPrtGen 2} prtDlciStatis OBJECT IDENTIFIER ::= {statisPrtGen 3} prtT1Statis OBJECT IDENTIFIER ::= {statisPrtGen 4} --prtFrStatis - Port Statistics for (FR) Frame Relay protocol prtFrStatisTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtFrStatisEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is applicable only for an active port running an FR protocol ." ::= { prtFrStatis 1} prtFrStatisEntry OBJECT-TYPE SYNTAX PrtFrStatisEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtFrStatisSltIdx, prtFrStatisPrtIdx, prtFrStatisInvIdx} ::= { prtFrStatisTable 1} PrtFrStatisEntry ::= SEQUENCE { prtFrStatisSltIdx INTEGER, prtFrStatisPrtIdx INTEGER, prtFrStatisInvIdx INTEGER, prtFrTimeElapsed Integer32, prtFrRxTotalFrames Counter32, prtFrTxTotalFrames Counter32, prtFrRxTotalBytes Counter32, prtFrTxTotalBytes Counter32, prtFrRxMngFrames Counter32, prtFrTxMngFrames Counter32, prtFrRxDeFrames Counter32, prtFrTxDeFrames Counter32, prtFrRxDcrdCongDeFr Counter32, prtFrTxDcrdCongDeFr Counter32, prtFrRxDcrdCongAllFr Counter32, prtFrTxDcrdCongAllFr Counter32, prtFrRxFecn Counter32, prtFrTxFecn Counter32, prtFrRxBecn Counter32, prtFrTxBecn Counter32, prtFrRxBeViol Counter32, prtFrTxBeViol Counter32, prtFrRxBcViol Counter32, prtFrTxBcViol Counter32 } prtFrStatisSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the module is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid. For stand-alone units this index will be notApplicable (255)." ::= { prtFrStatisEntry 1} prtFrStatisPrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number." ::= { prtFrStatisEntry 2} prtFrStatisInvIdx OBJECT-TYPE SYNTAX INTEGER { currentInv (1), last (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Interval of 15 min. for which the following statistics counters are applicable." ::= { prtFrStatisEntry 3} prtFrTimeElapsed OBJECT-TYPE SYNTAX Integer32 (0..899) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of seconds that have elapsed since the beginning of the current error-measurement interval. This object is applicable mainly for the current interval. For other interval: - if data is available: value will be 899. - if data is not available: value will be 0." ::= { prtFrStatisEntry 4 } prtFrRxTotalFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of frames received by this port during the selected interval." ::= { prtFrStatisEntry 5 } prtFrTxTotalFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of frames sent by this port during the selected interval." ::= { prtFrStatisEntry 6 } prtFrRxTotalBytes OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of bytes received by this port during the selected interval." ::= { prtFrStatisEntry 7 } prtFrTxTotalBytes OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of bytes sent by this port during the selected interval." ::= { prtFrStatisEntry 8 } prtFrRxMngFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The management number of frames received by this port during the selected interval." ::= { prtFrStatisEntry 9 } prtFrTxMngFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The management number of frames sent by this port during the selected interval." ::= { prtFrStatisEntry 10 } prtFrRxDeFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of De frames received by this port during the selected interval." ::= { prtFrStatisEntry 11 } prtFrTxDeFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of De frames sent by this port during the selected interval." ::= { prtFrStatisEntry 12 } prtFrRxDcrdCongDeFr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of De frames discarded due to congestion, received by this port during the selected interval." ::= { prtFrStatisEntry 13 } prtFrTxDcrdCongDeFr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of De frames discarded due to congestion, sent by this port during the selected interval." ::= { prtFrStatisEntry 14 } prtFrRxDcrdCongAllFr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "All the frames discarded due to congestion, received by this port during the selected interval." ::= { prtFrStatisEntry 15 } prtFrTxDcrdCongAllFr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "All the frames discarded due to congestion, sent by this port during the selected interval." ::= { prtFrStatisEntry 16 } prtFrRxFecn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of frames received by this port during the selected interval, indicating forward congestion." ::= { prtFrStatisEntry 17 } prtFrTxFecn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of frames sent by this port during the selected interval, indicating forward congestion." ::= { prtFrStatisEntry 18 } prtFrRxBecn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of frames received by this port during the selected interval, indicating backward congestion." ::= { prtFrStatisEntry 19 } prtFrTxBecn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of frames sent by this port during the selected interval, indicating backward congestion." ::= { prtFrStatisEntry 20 } prtFrRxBeViol OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of data frames received by this port during the selected interval, exceeding the Burst Excess value." ::= { prtFrStatisEntry 21 } prtFrTxBeViol OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of data frames sent by this port during the selected interval, exceeding the Burst Excess value." ::= { prtFrStatisEntry 22 } prtFrRxBcViol OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of data frames received by this port during the selected interval, exceeding the Burst Committed value." ::= { prtFrStatisEntry 23 } prtFrTxBcViol OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of data frames sent by this port during the selected interval, exceeding the Burst Committed value." ::= { prtFrStatisEntry 24 } --prtCrStatis - Port Statistics for (CR) Cell Relay protocol prtCrStatisTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtCrStatisEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is applicable only for an active port running a CR protocol ." ::= { prtCrStatis 1} prtCrStatisEntry OBJECT-TYPE SYNTAX PrtCrStatisEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtCrStatisSltIdx, prtCrStatisPrtIdx, prtCrStatisInvIdx} ::= { prtCrStatisTable 1} PrtCrStatisEntry ::= SEQUENCE { prtCrStatisSltIdx INTEGER, prtCrStatisPrtIdx INTEGER, prtCrStatisInvIdx INTEGER, prtCrTimeElapsed Integer32, prtCrRxTotalCells Counter32, prtCrTxTotalCells Counter32, prtCrRxDataCells Counter32, prtCrTxDataCells Counter32 } prtCrStatisSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the module is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid. For stand-alone units this index will be notApplicable (255)." ::= { prtCrStatisEntry 1} prtCrStatisPrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number." ::= { prtCrStatisEntry 2} prtCrStatisInvIdx OBJECT-TYPE SYNTAX INTEGER { currentInv (1), last (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Interval of 15 min. for which the following statistics counters are applicable." ::= { prtCrStatisEntry 3} prtCrTimeElapsed OBJECT-TYPE SYNTAX Integer32 (0..899) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of seconds that have elapsed since the beginning of the current error-measurement interval. This object is applicable mainly for the current interval. For other interval: - if data is available: value will be 899. - if data is not available: value will be 0." ::= { prtCrStatisEntry 4 } prtCrRxTotalCells OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of cells received by this port during the selected interval." ::= { prtCrStatisEntry 5 } prtCrTxTotalCells OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of cells sent by this port during the selected interval." ::= { prtCrStatisEntry 6 } prtCrRxDataCells OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Data Cells received by this port during the selected interval." ::= { prtCrStatisEntry 7 } prtCrTxDataCells OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Data Cells sent by this port during the selected interval." ::= { prtCrStatisEntry 8 } --prtDlciStatis - Port DLCI Statistics for FR, FR+ and CR protocol prtDlciStatisTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtDlciStatisEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is applicable only for an active port running an FR, FR+ or CR protocol, with valid DLCIs ." ::= { prtDlciStatis 1} prtDlciStatisEntry OBJECT-TYPE SYNTAX PrtDlciStatisEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtDlciSltIdx, prtDlciPrtIdx, prtDlciIdx} ::= { prtDlciStatisTable 1} PrtDlciStatisEntry ::= SEQUENCE { prtDlciSltIdx INTEGER, prtDlciPrtIdx INTEGER, prtDlciIdx Integer32, prtDlciRxDeFrames Counter32, prtDlciTxDeFrames Counter32, prtDlciRxDcrdCongDeFr Counter32, prtDlciTxDcrdCongDeFr Counter32, prtDlciRxDcrdCongAllFr Counter32, prtDlciTxDcrdCongAllFr Counter32, prtDlciTxFecn Counter32, prtDlciTxBecn Counter32, prtDlciRxBeViol Counter32, prtDlciTxBeViol Counter32, prtDlciRxBcViol Counter32, prtDlciTxBcViol Counter32 } prtDlciSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the module is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid. For stand-alone units this index will be notApplicable (255)." ::= { prtDlciStatisEntry 1} prtDlciPrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number." ::= { prtDlciStatisEntry 2} prtDlciIdx OBJECT-TYPE SYNTAX Integer32 (1..991) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique DLCI index for each valid DLCI (16..991). " ::= { prtDlciStatisEntry 3} prtDlciRxDeFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of De frames received by this DLCI." ::= { prtDlciStatisEntry 4 } prtDlciTxDeFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of De frames sent by this DLCI." ::= { prtDlciStatisEntry 5 } prtDlciRxDcrdCongDeFr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of De frames discarded due to congestion, received by this DLCI." ::= { prtDlciStatisEntry 6 } prtDlciTxDcrdCongDeFr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of De frames discarded due to congestion, sent by this DLCI." ::= { prtDlciStatisEntry 7 } prtDlciRxDcrdCongAllFr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "All the frames discarded due to congestion, received by this DLCI." ::= { prtDlciStatisEntry 8 } prtDlciTxDcrdCongAllFr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "All the frames discarded due to congestion, sent by this DLCI." ::= { prtDlciStatisEntry 9 } prtDlciTxFecn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of frames sent by this DLCI, indicating forward congestion." ::= { prtDlciStatisEntry 10 } prtDlciTxBecn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of frames sent by this DLCI, indicating backward congestion." ::= { prtDlciStatisEntry 11 } prtDlciRxBeViol OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of data frames received by this DLCI, exceeding the Burst Excess value." ::= { prtDlciStatisEntry 12 } prtDlciTxBeViol OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of data frames sent by this DLCI, exceeding the Burst Excess value." ::= { prtDlciStatisEntry 13 } prtDlciRxBcViol OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of data frames received by this DLCI, exceeding the Burst Committed value." ::= { prtDlciStatisEntry 14 } prtDlciTxBcViol OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of data frames sent by this DLCI, exceeding the Burst Committed value." ::= { prtDlciStatisEntry 15 } --prtT1 Last FDL Message Table - Statistics prtT1FdlMsgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtT1FdlMsgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is applicable for a T1 interface with 'esf' LineType ." ::= { prtT1Statis 1} prtT1FdlMsgEntry OBJECT-TYPE SYNTAX PrtT1FdlMsgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtT1FdlMsgSltIdx, prtT1FdlMsgPrtIdx, prtT1FdlMsgFdlTxRx} ::= { prtT1FdlMsgTable 1} PrtT1FdlMsgEntry ::= SEQUENCE { prtT1FdlMsgSltIdx INTEGER, prtT1FdlMsgPrtIdx INTEGER, prtT1FdlMsgFdlTxRx INTEGER, prtT1FdlMsg OCTET STRING } prtT1FdlMsgSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the module is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid." ::= { prtT1FdlMsgEntry 1} prtT1FdlMsgPrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number. MTML-1/T1 modules have just one external interface." ::= { prtT1FdlMsgEntry 2} prtT1FdlMsgFdlTxRx OBJECT-TYPE SYNTAX INTEGER { tx (1), rx (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Fdl tx/rx reference of the Fdl message." ::= { prtT1FdlMsgEntry 3} prtT1FdlMsg OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "FDL message." ::= { prtT1FdlMsgEntry 4} -- -- Extension of the Time Slot Config Table of ML ports -- -- Time Slot is split to 8 Bits prtExTsSplitTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtExTsSplitEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry, except prtExTsBitTest that will be written directly to the Active Configuration." ::= {cnfgPrtGen 1} prtExTsSplitEntry OBJECT-TYPE SYNTAX PrtExTsSplitEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtExTsCnfgIdx, prtExTsSltIdx, prtExTsPrtIdx, prtExTsIdx, prtExTsBit} ::= { prtExTsSplitTable 1} PrtExTsSplitEntry ::= SEQUENCE { prtExTsCnfgIdx Integer32, prtExTsSltIdx INTEGER, prtExTsPrtIdx Integer32, prtExTsIdx Integer32, prtExTsBit Integer32, prtExTsIConSlot INTEGER, prtExTsIConPrt Integer32, prtExTsBitTest INTEGER, prtExTsTxSignaling OCTET STRING, prtExTsRxSignaling OCTET STRING } prtExTsCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. " ::= { prtExTsSplitEntry 1} prtExTsSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid. notApplicable - for stand-alone units." ::= { prtExTsSplitEntry 2} prtExTsPrtIdx OBJECT-TYPE SYNTAX Integer32 -- For MP: -- { -- exPrt1 (1), -- inPrt1 (101) -- } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number. Most ML cards have only one external interface. inPrt1 - for MTML-H/E1 cards. For other products' index see their specification." ::= { prtExTsSplitEntry 3} prtExTsIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique time slot position. The valid time slots are: 1..24 for T1 Card and 1..31 for E1 interface. In G732S-E1 lines, time slot 16 is not valid for data, it is dedicated to multiframe synchronization bits and voice signaling." ::= { prtExTsSplitEntry 4} prtExTsBit OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique Bit within the time slot. The valid Bits are: 1..8." ::= { prtExTsSplitEntry 5} prtExTsIConSlot OBJECT-TYPE SYNTAX INTEGER { noConnect (2), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the specified time slot is connected/routed internally in the Agent and to which card it is connected. In the ?004 Unit the entries io6(10)..io12(16) are not valid. notApplicable - for stand-alone units." ::= {prtExTsSplitEntry 6} prtExTsIConPrt OBJECT-TYPE SYNTAX Integer32 -- For MP: -- { -- exPrt1 (1) , -- exPrt2 (2) , -- exPrt3 (3) , -- exPrt4 (4) , -- exPrt5 (5) , -- exPrt6 (6) , -- exPrt7 (7) , -- exPrt8 (8) , -- exPrt9 (9) , -- exPrt10 (10) , -- exPrt11 (11) , -- exPrt12 (12) , -- -- noConnect (100), -- -- inPrt1 (101) , -- inPrt2 (102) , -- inPrt3 (103) , -- inPrt4 (104) , -- inPrt5 (105) , -- inPrt6 (106) , -- inPrt7 (107) , -- inPrt8 (108) , -- inPrt9 (109) , -- inPrt10 (110) , -- inPrt11 (111) , -- inPrt12 (112) -- } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the internally (In Mux) connected/routed port. For other products' index see their specification." ::= {prtExTsSplitEntry 7} prtExTsBitTest OBJECT-TYPE SYNTAX INTEGER { none (1), remoteBert (8), localBert (30), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a test to be activated on the selected Bit. It is applicable only when prtExPh1MlTsTest=split(254). none - no test is applied for the selected Bit. notApplicable - when prtExPh1MlTsTest is NOT split(254)." ::= { prtExTsSplitEntry 8} prtExTsTxSignaling OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Tx Signaling per TS, for TSs having TS Type=Voice (agnTsType=voice(2)). It defines what is sent for the selected TS for A,B,C,D Signaling Bits. Bit 1= LSB Bit 8= MSB Bit 1-2 = A Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 3-4 = B Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 5-6 = C Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 7-8 = D Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA" ::= { prtExTsSplitEntry 9} prtExTsRxSignaling OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Tx Signaling per TS, for TSs having TS Type=Voice (agnTsType=voice(2)). It defines what is sent for the selected TS for A,B,C,D Signaling Bits. Bit 1= LSB Bit 8= MSB Bit 1-2 = A Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 3-4 = B Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 5-6 = C Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 7-8 = D Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA" ::= { prtExTsSplitEntry 10} prtCnfgAgenda OBJECT IDENTIFIER ::= {cnfgPrtGen 2} prtAgendaBehaviourTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtAgendaBehaviourEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= { prtCnfgAgenda 1} prtAgendaBehaviourEntry OBJECT-TYPE SYNTAX PrtAgendaBehaviourEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtAgendaBehaviourCnfgIdx, prtAgendaBehaviourSltIdx, prtAgendaBehaviourPrtIdx } ::= { prtAgendaBehaviourTable 1} PrtAgendaBehaviourEntry ::= SEQUENCE { prtAgendaBehaviourCnfgIdx Integer32, prtAgendaBehaviourSltIdx Integer32, prtAgendaBehaviourPrtIdx Integer32, prtAgendaBehaviourOnOff INTEGER } prtAgendaBehaviourCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. " ::= { prtAgendaBehaviourEntry 1} prtAgendaBehaviourSltIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter should be: - slot number for MX3000 - 255 = N/A for MX300/30. " ::= { prtAgendaBehaviourEntry 2 } prtAgendaBehaviourPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter should be: - port number for MX300/30 - 100 = N/A for MX3000. " ::= { prtAgendaBehaviourEntry 3 } prtAgendaBehaviourOnOff OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this command to on(3) enables the agenda function at module (3000) or port (300/30) level." DEFVAL { off } ::= { prtAgendaBehaviourEntry 4 } prtCnfgAgendaTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtCnfgAgendaEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table allows the user to schedule the time a session is active per week basis." ::= { prtCnfgAgenda 2} prtCnfgAgendaEntry OBJECT-TYPE SYNTAX PrtCnfgAgendaEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { prtCnfgAgendaCnfgIdx, prtCnfgAgendaSltIdx, prtCnfgAgendaPrtIdx, prtCnfgAgendaDayIdx, prtCnfgAgendaSesId } ::= { prtCnfgAgendaTable 1} PrtCnfgAgendaEntry ::= SEQUENCE { prtCnfgAgendaCnfgIdx Integer32, prtCnfgAgendaSltIdx Integer32, prtCnfgAgendaPrtIdx Integer32, prtCnfgAgendaDayIdx INTEGER, prtCnfgAgendaSesId Integer32, prtCnfgAgendaFrom Integer32, prtCnfgAgendaTo Integer32 } prtCnfgAgendaCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. " ::= { prtCnfgAgendaEntry 1} prtCnfgAgendaSltIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute is equal to: -slot number for MX3000 -255 = N/A for MX300/30" ::= { prtCnfgAgendaEntry 2} prtCnfgAgendaPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute is equal to: - port number for MX300/30 - port number for MX3000. For example 1-4 in MHS-4 cards. - 100 = N/A for MX3000 when not used." ::= { prtCnfgAgendaEntry 3} prtCnfgAgendaDayIdx OBJECT-TYPE SYNTAX INTEGER { monday (1), tuesday (2), wednesday(3), thursday (4), friday (5), saturday (6), sunday (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute for which day of the week this row applies." ::= { prtCnfgAgendaEntry 4 } prtCnfgAgendaSesId OBJECT-TYPE SYNTAX Integer32 (1..4) MAX-ACCESS read-only STATUS current DESCRIPTION "The user may define 4 different active intervals per day." ::= { prtCnfgAgendaEntry 5 } prtCnfgAgendaFrom OBJECT-TYPE SYNTAX Integer32 (0..86400) MAX-ACCESS read-write STATUS current DESCRIPTION "Start from time interval in seconds." DEFVAL {86400} ::= { prtCnfgAgendaEntry 6 } prtCnfgAgendaTo OBJECT-TYPE SYNTAX Integer32 (0..86400) MAX-ACCESS read-write STATUS current DESCRIPTION "To time interval in seconds." DEFVAL {86400} ::= { prtCnfgAgendaEntry 7 } -- General Port Configuration parameters prtGenCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtGenCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table allows the user to configure general port parameters." ::= {cnfgPrtGen 3} prtGenCnfgEntry OBJECT-TYPE SYNTAX PrtGenCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { prtGenCnfgIdx, prtGenCnfgSltIdx, prtGenCnfgPrtIdx } ::= { prtGenCnfgTable 1} PrtGenCnfgEntry ::= SEQUENCE { prtGenCnfgIdx Integer32, prtGenCnfgSltIdx INTEGER, prtGenCnfgPrtIdx Integer32, prtGenCnfgLinkToSlot INTEGER, prtGenCnfgLinkToPort Integer32, prtGenCnfgPortId Integer32 } prtGenCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. The write operation is valid only to the TmpCnfg." ::= { prtGenCnfgEntry 1} prtGenCnfgSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted." ::= { prtGenCnfgEntry 2} prtGenCnfgPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique external or internal port number. For MP: exPrt1 (1) .. exPrt16 (16) , notApplicable(100), inPrt1 (101) .. inPrt48 (148) " ::= { prtGenCnfgEntry 3} prtGenCnfgLinkToSlot OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the slot of the ML card to which the IO port is mapped." ::= { prtGenCnfgEntry 4} prtGenCnfgLinkToPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the port in the prtGenCnfgLinkToSlot of the ML card to which the IO port is mapped. For MP: exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , inPrt1 (101) , inPrt2 (102) , inPrt3 (103) , inPrt4 (104) , notApplicable (255)" ::= { prtGenCnfgEntry 5} prtGenCnfgPortId OBJECT-TYPE SYNTAX Integer32 (0..16777215) MAX-ACCESS read-write STATUS current DESCRIPTION "IO Port Id for V5.1 use. This object is applicable only for part of the PSTN and ISDN IO ports. Generally, 0 is a valid value. Nevertheless, for ports that do not support this object, the value will be: notApplicable= 0" ::= { prtGenCnfgEntry 6} -- -- Compressed information. -- -- Specially for RadView management station -- prtCmprTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtCmprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= { cmprPrtGen 1 } prtCmprEntry OBJECT-TYPE SYNTAX PrtCmprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtCmprTypIdx, prtCmprCnfgIdx,prtCmprVersion,prtCmprSltIdx,prtCmprPrtIdx} ::= {prtCmprTable 1} PrtCmprEntry ::= SEQUENCE { prtCmprTypIdx Integer32, prtCmprCnfgIdx Integer32, prtCmprVersion Integer32, prtCmprSltIdx INTEGER, prtCmprPrtIdx Integer32, prtCmprObj OCTET STRING, prtCmprStatisticObj OCTET STRING } prtCmprTypIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Type of the Compressed being referred." ::= { prtCmprEntry 1} prtCmprCnfgIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the configuration to which the Compressed information is related." ::= { prtCmprEntry 2} prtCmprVersion OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the version of the internal format of the Compressed data" ::= { prtCmprEntry 3} prtCmprSltIdx OBJECT-TYPE SYNTAX INTEGER { psA (1), psB (2), clA (3), clB (4), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique number of the slot position where the card is inserted. In the ?004 Unit the entries psB(2),clB(4),io6(10)..io(16) are not valid." ::= { prtCmprEntry 4} prtCmprPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique identifier of the port the compressed information relates to. Valid values: exPrt1 (1) .. exPrt16 (16) , inPrt1 (101) .. inPrt48 (148)." ::= { prtCmprEntry 5} prtCmprObj OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute is the compressed information itself." ::= { prtCmprEntry 6} prtCmprStatisticObj OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute is the compressed statistics information itself." ::= { prtCmprEntry 7} -- Compressed Dlci table in the Port level -- The only way of reading this table is by the command 'GET NEXT' prtDlciCmprTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtDlciCmprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= { cmprPrtGen 2 } prtDlciCmprEntry OBJECT-TYPE SYNTAX PrtDlciCmprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtDlciCmprCnfgIdx,prtDlciCmprVersion, prtDlciCmprSltIdx,prtDlciCmprPrtIdx,prtDlciCmprDlciIdx} ::= {prtDlciCmprTable 1} PrtDlciCmprEntry ::= SEQUENCE { prtDlciCmprCnfgIdx Integer32, prtDlciCmprVersion Integer32, prtDlciCmprSltIdx INTEGER, prtDlciCmprPrtIdx INTEGER, prtDlciCmprDlciIdx Integer32, prtDlciCmprObj OCTET STRING } prtDlciCmprCnfgIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the configuration to which the Compressed information is related." ::= { prtDlciCmprEntry 1} prtDlciCmprVersion OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the version of the internal format of the Compressed data" ::= { prtDlciCmprEntry 2} prtDlciCmprSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique number of the slot position where the module is inserted. In the ?004 Unit the entries psB(2),clB(4),io6(10)..io(16) are not valid." ::= { prtDlciCmprEntry 3} prtDlciCmprPrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) , exPrt7 (7) , exPrt8 (8) , exPrt9 (9) , exPrt10 (10) , inPrt1 (101) , inPrt2 (102) , inPrt3 (103) , inPrt4 (104) , inPrt5 (105) , inPrt6 (106) , inPrt7 (107) , inPrt8 (108) , inPrt9 (109) , inPrt10 (110) , inPrt11 (111) , inPrt12 (112) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique identifier of the port the compressed information relates to. All the values are valid." ::= { prtDlciCmprEntry 4} prtDlciCmprDlciIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique identifier of the Dlci the compressed information relates to. The values are between 16 - 991." ::= { prtDlciCmprEntry 5} prtDlciCmprObj OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute is the compressed information itself." ::= { prtDlciCmprEntry 6} -- Compressed Alarm table in the Port level -- The only way of reading this table is by the command 'GET NEXT' prtAlarmsCmprTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtAlarmsCmprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= {cmprPrtGen 3} prtAlarmsCmprEntry OBJECT-TYPE SYNTAX PrtAlarmsCmprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtAlarmsCmprVersion,prtAlarmsCmprAlarmSlot, prtAlarmsCmprAlarmPort,prtAlarmsCmprAlarmIdx} ::= {prtAlarmsCmprTable 1} PrtAlarmsCmprEntry ::= SEQUENCE { prtAlarmsCmprVersion Integer32, prtAlarmsCmprAlarmSlot Integer32, prtAlarmsCmprAlarmPort Integer32, prtAlarmsCmprAlarmIdx Integer32, prtAlarmsCmprObj OCTET STRING } prtAlarmsCmprVersion OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the version of the internal format of the Compressed data" ::= { prtAlarmsCmprEntry 1} prtAlarmsCmprAlarmSlot OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the desired slot position. In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io(16) are not valid. For Stand-alone units, notApplicable(255) will appear." ::= { prtAlarmsCmprEntry 2} prtAlarmsCmprAlarmPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique identifier of the port the alarm applies to. All the values are valid. No alarms exist for a non-existing port. IP Bundles are considered a port too, for this matter." ::= { prtAlarmsCmprEntry 3} prtAlarmsCmprAlarmIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique number to identify an entry in the alarm status table of the agent." ::= { prtAlarmsCmprEntry 4} prtAlarmsCmprObj OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute is the compressed information itself." ::= { prtAlarmsCmprEntry 5} -- -- Specific port status for each module Type -- ***************************************** -- -- Megaplex?000/?004 port specific status for HS(TDM) modules -- HS-2,HS-3,HS-Q, HS-6, HS-12 prtSExHsfStatTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtSExHsfStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= {statPrtMux 6} prtSExHsfStatEntry OBJECT-TYPE SYNTAX PrtSExHsfStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtSExHsfSltIdx, prtSExHsfPrtIdx } ::= {prtSExHsfStatTable 1} PrtSExHsfStatEntry ::= SEQUENCE { prtSExHsfSltIdx INTEGER, prtSExHsfPrtIdx INTEGER, prtSExHsfInterfaceTyp INTEGER, prtSExHsfRts INTEGER } prtSExHsfSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid." ::= { prtSExHsfStatEntry 1} prtSExHsfPrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) , exPrt7 (7) , exPrt8 (8) , exPrt9 (9) , exPrt10 (10) , exPrt11 (11) , exPrt12 (12) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number. " ::= { prtSExHsfStatEntry 2} prtSExHsfInterfaceTyp OBJECT-TYPE SYNTAX INTEGER { unknown (1), v35 (2), rs422 (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique interface type of a selected port." ::= { prtSExHsfStatEntry 3} prtSExHsfRts OBJECT-TYPE SYNTAX INTEGER { unknown (1), notActive (2), active (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique RTS control signal state." ::= { prtSExHsfStatEntry 4} cnfgMdlMux OBJECT IDENTIFIER ::= {mdlMux 1} mdlPbxFramerCnfg OBJECT IDENTIFIER ::= {cnfgMdlMux 1} mdlPbxFramerCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF MdlPbxFramerCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains parameters relevant to a module belonging to a digital voice system, except mdlPbxFraEnhEcho which is relevant also for analog cards." ::= {mdlPbxFramerCnfg 1} mdlPbxFramerCnfgEntry OBJECT-TYPE SYNTAX MdlPbxFramerCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { mdlPbxFraCnfgIdx, mdlPbxFraSltIdx } ::= {mdlPbxFramerCnfgTable 1} MdlPbxFramerCnfgEntry ::= SEQUENCE { mdlPbxFraCnfgIdx Integer32, mdlPbxFraSltIdx INTEGER, mdlPbxFraEnhEcho INTEGER, mdlPbxFraTSGroupAss INTEGER, mdlPbxFraSignalMode INTEGER, mdlPbxFraSignalVector OCTET STRING, mdlPbxFraSignalMask OCTET STRING, mdlPbxFraFramerSlot INTEGER, mdlPbxFraSignaling INTEGER, mdlPbxFraTransSigTs Integer32 } mdlPbxFraCnfgIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. " DEFVAL {1} ::= { mdlPbxFramerCnfgEntry 1} mdlPbxFraSltIdx OBJECT-TYPE SYNTAX INTEGER{ io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16) } MAX-ACCESS read-only STATUS current DESCRIPTION "The slot relevant to this module." ::= { mdlPbxFramerCnfgEntry 2} mdlPbxFraEnhEcho OBJECT-TYPE SYNTAX INTEGER { notApplicable(1) , disabled(2), ms16(3), ms32(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Refers to external ports of an analogue module and to the internal ports of the other mvc4 types of modules. ms16(3) means that the four voice ports have enhanced echo of 16ms. ms32(4) means that the two first ports have enhanced echo of 32 ms while the last two ports have no enhanced echo." ::= { mdlPbxFramerCnfgEntry 3} mdlPbxFraTSGroupAss OBJECT-TYPE SYNTAX INTEGER{ group1(1), group2(2), group3(3), group4(4), group5(5), group6(6), group7(7), group8(8), notApplicable(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "In case of T1 modules: group1=(1,2,3,4), ...., group6=(21,22,23,24) while in case of E1 modules: - If prtExPh1MlLineType=g732sE1 or g732sE1CRC: group1=(1,2,3,4),..,group4=(13,14,15,17), group5=(18,19,20,21),...,group7=(26,27,28,29) group8=(30,31). - If prtExPh1MlLineType=g732nE1 or g732nE1CRC: group1=(1,2,3,4),..,group4=(13,14,15,16), group5=(17,18,19,20),...,group7=(25,26,27,28) group8=(29,30,31)." ::= { mdlPbxFramerCnfgEntry 4} mdlPbxFraSignalMode OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), tieTrunk(2), tieInvert(3), casTrans(4), userDefined(5), ccsTrans(6), noSignaling(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "Refers to the signaling mode of the Framer module. tieTrunk(2), tieInvert(3), casTrans(4) are standard coding of the signaling protocol. casTrans(4) is Channel Associated Signaling (the signaling is within the channels time slot). ccsTrans(6) is Transparent Common Channel Signaling (the signaling is not within the channels time slot - a TS for signaling is used). userDefined(5) allows the user to define the signaling protocol he wants. In this case, the next two MIB fields are relevant." DEFVAL { casTrans } ::= { mdlPbxFramerCnfgEntry 5} mdlPbxFraSignalVector OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "In the case of mdlPbxFraSignalMode = userDefined(5), this field defines the A,B,C Bits. D bit is supplied for future versions. Bit 1 = Bit A ON Hook - Local Bit 2 = Bit B ON Hook - Local Bit 3 = Bit C ON Hook - Local Bit 4 = Bit D ON Hook - Local Bit 5 = Bit A OFF Hook - Local Bit 6 = Bit B OFF Hook - Local Bit 7 = Bit C OFF Hook - Local Bit 8 = Bit D OFF Hook - Local Bit 9 = Bit A ON Hook - Remote Bit 10 = Bit B ON Hook - Remote Bit 11 = Bit C ON Hook - Remote Bit 12 = Bit D ON Hook - Remote Bit 13 = Bit A OFF Hook - Remote Bit 14 = Bit B OFF Hook - Remote Bit 15 = Bit C OFF Hook - Remote Bit 16 = Bit D OFF Hook - Remote In conjunction with the Mask, mdlPbxFraSignalMask, it is possible to compute the signal mode." DEFVAL { '0000'H} ::= { mdlPbxFramerCnfgEntry 6} mdlPbxFraSignalMask OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "In the case of mdlPbxFraSignalMode = userDefined(5), this field defines the 'don't care' A,B,C Bits. D bit is supplied for future versions. Bit 1 = Bit A ON Hook - Local Bit 2 = Bit B ON Hook - Local Bit 3 = Bit C ON Hook - Local Bit 4 = Bit D ON Hook - Local Bit 5 = Bit A OFF Hook - Local Bit 6 = Bit B OFF Hook - Local Bit 7 = Bit C OFF Hook - Local Bit 8 = Bit D OFF Hook - Local Bit 9 = Bit A ON Hook - Remote Bit 10 = Bit B ON Hook - Remote Bit 11 = Bit C ON Hook - Remote Bit 12 = Bit D ON Hook - Remote Bit 13 = Bit A OFF Hook - Remote Bit 14 = Bit B OFF Hook - Remote Bit 15 = Bit C OFF Hook - Remote Bit 16 = Bit D OFF Hook - Remote." DEFVAL { 'ffff'H } ::= { mdlPbxFramerCnfgEntry 7} mdlPbxFraFramerSlot OBJECT-TYPE SYNTAX INTEGER { io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16) } MAX-ACCESS read-write STATUS current DESCRIPTION "Slot where is sitting the Framer." ::= { mdlPbxFramerCnfgEntry 8} mdlPbxFraSignaling OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), endToEnd (2), localTermination(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Signaling - describes the way the signaling ABCD bits pass from the local extension to the remote extension and vice-versa. endToEnd = the signaling ABCD bits pass without change from local to remote extension. localTermination = the signaling ABCD bits received from the local extension are translated to different ON Hook/OFF Hook bit values and then passed to remote extension. This is relevant when the Local and Remote ON Hook/OFF Hook values are different." DEFVAL { endToEnd } ::= { mdlPbxFramerCnfgEntry 9} mdlPbxFraTransSigTs OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This is the Time Slot that is used for Transparent CCS signaling. The values of this TS are 1-24 for T1 & 1-31 for E1. The default for E1 is 16 & for T1 it is 24. If no signaling is used then the TS should be 255 (None)." ::= { mdlPbxFramerCnfgEntry 10} -- -- Specific port config for each module Type -- ***************************************** -- -- MPCL.1 configuration parameters -- --prtExClCnfgTable OBJECT IDENTIFIER ::= {prtClCnfg 1} -- prtInClInbandTable OBJECT IDENTIFIER ::= {prtClCnfg 2} prtExClCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtExClCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= {prtClCnfg 1} prtExClCnfgEntry OBJECT-TYPE SYNTAX PrtExClCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "All the entries at this table are identical (have the same value) for all the configurations (1..100) except the TmpCnfg. The write operation into the Table Objects is valid only to the TmpCnfg entry." INDEX {prtExClCnfgIdx, prtExClSltIdx, prtExClPrtIdx } ::= { prtExClCnfgTable 1} PrtExClCnfgEntry ::= SEQUENCE { prtExClCnfgIdx Integer32, prtExClSltIdx INTEGER, prtExClPrtIdx INTEGER, prtExClUsage INTEGER, prtExClRate INTEGER, prtExClDataBits INTEGER, prtExClParity INTEGER, prtExClStopBits INTEGER, prtExClRoutingProtocol INTEGER, prtExClEnabled INTEGER } prtExClCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg." ::= { prtExClCnfgEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. prtExClSltIdx OBJECT-TYPE SYNTAX INTEGER { clA (3), clB (4), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. Because the second Cl is only for redundancy, all the parameters are identical in the two modules, i.e. change of any parameter in one module will change automatically the value of the other module.. In the ?004 Unit the entry clB(4) is not valid." ::= { prtExClCnfgEntry 2} prtExClPrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) , exPrt2 (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number. " ::= { prtExClCnfgEntry 3} prtExClUsage OBJECT-TYPE SYNTAX INTEGER { unknown (1), noUse (2), nmsSlip (3), nmsPpp (4), muxSlip (5), muxPpp (6), terminal(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates what is the usage of the port." ::= { prtExClCnfgEntry 4} prtExClRate OBJECT-TYPE SYNTAX INTEGER { r300Bps (1), r1200Bps (2), r2400Bps (3), r4800Bps (4), r9600Bps (5), r19200Bps (6), r38400Bps (7), r57600Bps (8), r115200Bps (9) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the operation rate of the port." ::= { prtExClCnfgEntry 5} prtExClDataBits OBJECT-TYPE SYNTAX INTEGER { dataBits7Bits (1), dataBits8Bits (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the number of data bits in async frame" ::= { prtExClCnfgEntry 6} prtExClParity OBJECT-TYPE SYNTAX INTEGER { odd (1), even (2), none (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates if the parity operation mode in async frame" ::= { prtExClCnfgEntry 7} prtExClStopBits OBJECT-TYPE SYNTAX INTEGER { stopBits1Bit (1), stopBits1dot5Bits (2), stopBits2Bits (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the minimum number of stop bits in the tx async frame" ::= { prtExClCnfgEntry 8} prtExClRoutingProtocol OBJECT-TYPE SYNTAX INTEGER { none (1), rip2 (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the routing protocol of the port. When prtExClUsage is nmsSlip or nmsPpp - all values are applicable . Else - only 'none' is applicable." ::= { prtExClCnfgEntry 9} prtExClEnabled OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), disabled (2), enabled (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates if Ethernet port of CL is enabled or not for management. It is applicable only on the ETH port of the CL, when the MP includes an ML-IP card. disabled - will happen when there is Inband Management via the ML-IP link/s enabled - will happen when ML-IP link/s is not used for Inband Management, but CL's ETH port ." ::= { prtExClCnfgEntry 10} -- -- MPH1.T1, MPH1.E1, MTML.1/T1 , MTML.1/E1, ML-20 -- TDM and Hybrid(TDM & Packet) Main Link Modules -- --prtExPh1MlCnfgTable OBJECT IDENTIFIER ::= {prtPh1MlCnfg 1} --prtExPh1MlTsTable OBJECT IDENTIFIER ::= {prtPh1MlCnfg 2} --prtInPh1MlCnfgTable OBJECT IDENTIFIER ::= {prtPh1MlCnfg 3} --prtInPh1MlDlciTable OBJECT IDENTIFIER ::= {prtPh1MlCnfg 4} --prtPhMlCnfgTable OBJECT IDENTIFIER ::= {prtPh1MlCnfg 5} -- -- T1/E1 Port Objects -- prtExPh1MlCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtExPh1MlCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= {prtPh1MlCnfg 1} prtExPh1MlCnfgEntry OBJECT-TYPE SYNTAX PrtExPh1MlCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtExPh1MlCnfgIdx, prtExPh1MlSltIdx, prtExPh1MlPrtIdx } ::= { prtExPh1MlCnfgTable 1} PrtExPh1MlCnfgEntry ::= SEQUENCE { prtExPh1MlCnfgIdx Integer32, prtExPh1MlSltIdx INTEGER, prtExPh1MlPrtIdx INTEGER, prtExPh1MlConnect INTEGER, prtExPh1MlLineType INTEGER, prtExPh1MlLineCode INTEGER, prtExPh1MlLineLen INTEGER, prtExPh1MlRestoreTime INTEGER, prtExPh1MlTxGain INTEGER, prtExPh1MlRxSensitivity INTEGER, prtExPh1MlIdleCode Integer32, prtExPh1MlTdmTrunk INTEGER, prtExPh1MlClkMode INTEGER, prtExPh1MlMfClkSrcSlt INTEGER, prtExPh1MlMfClkSrcPrt INTEGER, prtExPh1MlFdlType INTEGER, prtExPh1MlInbandMng INTEGER, prtExPh1MlInbandMngRate INTEGER, prtExPh1MlRedundType INTEGER, prtExPh1MlRedundSlot INTEGER, prtExPh1MlRedundPort INTEGER, prtExPh1MlRedundRecTime Integer32, prtExPh1MlInbandMngRoutProt INTEGER, prtExPh1MlIfType INTEGER, prtExPh1MlMultiplier INTEGER, prtExPh1MlSupportedTS INTEGER } prtExPh1MlCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. " ::= { prtExPh1MlCnfgEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. prtExPh1MlSltIdx OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the module is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid. For the Vmux2100 Main Board notApplicable (1) is used." ::= { prtExPh1MlCnfgEntry 2} prtExPh1MlPrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1), exPrt2 (2), exPrt3 (3), exPrt4 (4), inPrt1 (101), inPrt2 (102), inPrt3 (103), inPrt4 (104) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number. MTML-1/E1 and MTML-1/T1 cards have only one external interface. inPrt1, inPrt2 - for MTML-H/2E1 and HSH cards. inPrt1..inPrt4 - for MTML-E2 cards. exPrt2..exPrt4 - for MTML-4 cards and others." ::= { prtExPh1MlCnfgEntry 3} prtExPh1MlConnect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port should be considered in any of the mux algorithms. It also affects all the card considerations because it may indicate that the module has only one physical interface." ::= {prtExPh1MlCnfgEntry 4} prtExPh1MlLineType OBJECT-TYPE SYNTAX INTEGER { esfT1 (2), --> dsx1ESF sfT1 (3), --> dsx1D4 g732nE1 (4), --> dsx1E1 g732nE1CRC (5), --> dsx1E1-CRC g732sE1 (6), --> dsx1E1-MF g732sE1CRC (7) --> dsx1E1-MF-CRC } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute is the line type parameter for T1/E1 interface. The user should select only the parameters which are relevant to the specific card: T1 line code parameters for the MPH.1/T1 E1 line code parameters for the MPH.1/E1. This parameter has the same values as dsx1LineType in T1/E1 MIB (RFC-1406). The parameters in dsx1LineType are: other (1) esfT1 dsx1ESF (2) sfT1 dsx1D4 (3) g732nE1 dsx1E1 (4) g732nE1CRC dsx1E1-CRC (5) g732sE1 dsx1E1-MF (6) g732sE1CRC dsx1E1-MF-CRC (7)" ::= { prtExPh1MlCnfgEntry 5} prtExPh1MlLineCode OBJECT-TYPE SYNTAX INTEGER { b7T1 (1), --> dsx1JBZS (for E1 & T1) b8zsT1 (2), --> dsx1B8ZS (for E1 & T1) transT1(3), --> dsx1AMI hdb3E1 (4), --> dsx1HDB3 (for E1 & T1) notApplicable(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute is the line code parameter used for T1/E1 interface. The user should select only the parameters which are relevant to the specific card: T1 line code parameters for MPH.1/T1 E1 line code parameters for MPH.1/E1. This parameter has the same values as dsx1LineCoding in T1/E1 MIB (RFC-1406). The parameters in dsx1LineCoding are: dsx1JBZS (1) dsx1B8ZS (2) dsx1HDB3 (3) dsx1ZBTSI (4) dsx1AMI (5) other (6)" ::= { prtExPh1MlCnfgEntry 6} prtExPh1MlLineLen OBJECT-TYPE SYNTAX INTEGER { unknown (1), len0p133ft (2), len134p266ft (3), len267p399ft (4), len400p533ft (5), len534p655ft (6), lenFcc68 (7), notApplicable(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute is the line length parameter used only for T1/DSU interfaces. lenXXXpXXXft = len-XXX-XXXft." ::= { prtExPh1MlCnfgEntry 7} prtExPh1MlRestoreTime OBJECT-TYPE SYNTAX INTEGER { restoreT1secFast (2), restoreT10sec62411 (3), ccittE1 (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The time passing from the disappearance of the loss of synchronization condition (red alarm) to the restoration of normal service. The options 1secFast(2) and 10sec62411(3) for E1 interfaces are proprietary implementation of the T1 standard to the E1 interface." ::= { prtExPh1MlCnfgEntry 8} prtExPh1MlTxGain OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), txGain0db (2), txGain7dot5db (3), txGain15db (4), txGain22dot5db (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute is the tx gain parameter used only for T1/CSU interfaces." ::= { prtExPh1MlCnfgEntry 9} prtExPh1MlRxSensitivity OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), low26dBm (2), high36dBm (3), shortHaul (4), longHaul (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute is the rx line sensitivity parameter. low26dBm, high36dBm - applicable for T1-CSU shortHaul, longHaul - applicable for MTML-4 cards." ::= { prtExPh1MlCnfgEntry 10} prtExPh1MlIdleCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Determines the code for transmission in empty time slots. Type value(00-FFH), Excluding 0H,8H,10H,12H,21H,24H,42H,49H, 84H,92H" ::= { prtExPh1MlCnfgEntry 11} prtExPh1MlTdmTrunk OBJECT-TYPE SYNTAX INTEGER { linkA (1), linkB (2), none (3), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port is used to transfer TDM cards data and through which Bus." ::= {prtExPh1MlCnfgEntry 12} prtExPh1MlClkMode OBJECT-TYPE SYNTAX INTEGER { internalLocal (1), loopBackLocal (2), nodalTiming (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the clock operation mode of the T1/E1 interface. Ports that are connected to the TDM Buses must be in nodalTiming(3) clock mode. " ::= {prtExPh1MlCnfgEntry 13} prtExPh1MlMfClkSrcSlt OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), local (2), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port Tx multiframe is synchronized with Rx multiframe of another port and the slot position of that port. This operation is required in order to bypass signaling of PCM voice channels. Its value is always local(2) when the port isn't connected to any TDM bus. When it's value is local(2) there is no meaning to 'prtExPh1MlMfClkSrcPrt' parameter. In the ?004 Unit the entries io6(10)..io16) are not valid" ::= {prtExPh1MlCnfgEntry 14} prtExPh1MlMfClkSrcPrt OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1), exPrt2 (2), inPrt1 (101), notApplicable(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "A unique number to identify a port position in the mux. It has no effect when the prtExPh1MlMfClkSrcSlt selected is Local. inPrt1 - for MTML-H/E1 cards." ::= {prtExPh1MlCnfgEntry 15} prtExPh1MlFdlType OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), response (2), command (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "A unique number to identify the side of the FDL operation. Normal: 'response' for the user side and 'command' for the PTT side. Applicable only when working with ESF-T1 link" ::= {prtExPh1MlCnfgEntry 16} prtExPh1MlInbandMng OBJECT-TYPE SYNTAX INTEGER { off (2), fdlOrTs0 (3), dedicatedTs (4), dedicatedPpp (5), dedicatedFr (6), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "A unique number to identify an Inband management over the link." ::= {prtExPh1MlCnfgEntry 17} prtExPh1MlInbandMngRate OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), r4k (2), r8k (3), r12k (4), r16k (5), r32k (6), r64k (7), r20k (8) } MAX-ACCESS read-write STATUS current DESCRIPTION "A unique number to identify the rate of the Inband management. E1 port - it is not applicable when prtExPh1MlInbandMng selected is off. T1 port - it is not applicable when prtExPh1MlInbandMng selected is off OR fdlOrTs0." ::= {prtExPh1MlCnfgEntry 18} prtExPh1MlRedundType OBJECT-TYPE SYNTAX INTEGER { none (1), dualCableAIS (2), yCable (3), dualCableParallelTx (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object determines the ML redundancy type: none - no ML redundacy dualCableAIS - each ML card is connected by a separate dualCableParallelTx cable to the other MUX (two cables connect two MUXes). There are two types of dual redundancy. yCable - Y cable is connected to both ML cards (one cable connects two MUXes). Default=none When only one ML card exists, the type can be only 'none'. The value should be the same for both ML slots." ::= {prtExPh1MlCnfgEntry 19} prtExPh1MlRedundSlot OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the slot containing the redundacy ML card, coupled with the current ML (prtExPh1MlSltIdx). When prtExPh1MlRedundType=none (no ML redundancy) this object will be 'notApplicable'. In the ?004 Unit the entries io6(10)..io12(16) are not valid When value is not 'none', it should be mutual to the redundant ML slot." ::= {prtExPh1MlCnfgEntry 20} prtExPh1MlRedundPort OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1), exPrt2 (2), exPrt3 (3), exPrt4 (4), inPrt1 (101), inPrt2 (102), inPrt3 (103), inPrt4 (104), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the redundacy ML port, coupled with the current ML port (prtExPh1MlPrtIdx). When prtExPh1MlRedundType=none (no ML redundancy) this object will be 'notApplicable'. When value is not 'none', it should be mutual to the redundant ML port. inPrt1 - for MTML-H/E1 cards. inPrt1..inPrt4 - for MTML-E2 cards. exPrt2..exPrt4 - for MTML-4 cards." ::= {prtExPh1MlCnfgEntry 21} prtExPh1MlRedundRecTime OBJECT-TYPE SYNTAX Integer32 (1..99) MAX-ACCESS read-write STATUS current DESCRIPTION "Redundancy Recovery Time (sec). After switching the ML card to the current (prtExPh1MlSltIdx), the next ML switch can be performed only after a minimum time, indicated by this object." ::= {prtExPh1MlCnfgEntry 22} prtExPh1MlInbandMngRoutProt OBJECT-TYPE SYNTAX INTEGER { none (1), rip2 (2), proprietary (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the Inband Mng routing protocol of the port." ::= {prtExPh1MlCnfgEntry 23} prtExPh1MlIfType OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), csu (2), dsu (3), ltu (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Interface type of the port. For T1 - csu, dsu are the valid values For E1 - dsu, ltu are the valid values." ::= {prtExPh1MlCnfgEntry 24} prtExPh1MlMultiplier OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), br56 (2), br64 (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The data rate of each TS. The multiplier values can be 56 kbps or 64 kbps." ::= {prtExPh1MlCnfgEntry 25} prtExPh1MlSupportedTS OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Number of Supported Time Slots by the agent. For Vmux-110 there is HW that supports less than 31/24 Time Slots for the E1/T1 port." ::= {prtExPh1MlCnfgEntry 26} -- -- MPH1.T1 & MPH1.E1 -- Time Slot Assignment Table -- prtExPh1MlTsTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtExPh1MlTsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry, except prtExPh1MlTsTest that will be written directly to the Active Configuration." ::= {prtPh1MlCnfg 2} prtExPh1MlTsEntry OBJECT-TYPE SYNTAX PrtExPh1MlTsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtExPh1MlTsCnfgIdx, prtExPh1MlTsSltIdx, prtExPh1MlTsPrtIdx, prtExPh1MlTsIdx } ::= { prtExPh1MlTsTable 1} PrtExPh1MlTsEntry ::= SEQUENCE { prtExPh1MlTsCnfgIdx Integer32, prtExPh1MlTsSltIdx INTEGER, prtExPh1MlTsPrtIdx INTEGER, prtExPh1MlTsIdx Integer32, prtExPh1MlTsIConSlot INTEGER, prtExPh1MlTsIConPrt Integer32, prtExPh1MlTsIConTs Integer32, prtExPh1MlTsExt OBJECT IDENTIFIER, prtExPh1MlTsTest INTEGER, prtExPh1MlTsType INTEGER, prtExPh1MlTsBundle INTEGER, prtExPh1MlTsTestDuration Integer32 } prtExPh1MlTsCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. " ::= { prtExPh1MlTsEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. prtExPh1MlTsSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid. For the Vmux2100 Main Board notApplicable (255) is used." ::= { prtExPh1MlTsEntry 2} prtExPh1MlTsPrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1), exPrt2 (2), exPrt3 (3), exPrt4 (4), inPrt1 (101) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number. MPH.1/E1 and MPH.1/T1 cards have only one external interface. exPrt2 - for ME1-2, MT1-2 and mhsPri cards. exPrt3, exPrt4 - for mhsPri cards. inPrt1 - for MTML-H/E1 cards." ::= { prtExPh1MlTsEntry 3} prtExPh1MlTsIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique time slot position. The valid time slots are 1..24 for T1 Card and 1..31 for E1 interface. In G732S-E1 lines time slot 16 is not valid for data, it is dedicated for multiframe synchronization bits and voice signaling." ::= { prtExPh1MlTsEntry 4} prtExPh1MlTsIConSlot OBJECT-TYPE SYNTAX INTEGER { unknown (1), noConnect (2), split (4), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the specified time slot is connected/routed internally in the Agent and to which card it is connected. In the ?004 Unit the entries io6(10)..io16) are not valid. split - will be used when the Src TS is connected to more than one slot OR more than one port (each needing less than a whole TS)." ::= {prtExPh1MlTsEntry 5} prtExPh1MlTsIConPrt OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the internally (In Mux) connected/routed port. For MP, the values will be: { exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) , exPrt7 (7) , exPrt8 (8) , exPrt9 (9) , exPrt10 (10) , exPrt11 (11) , exPrt12 (12) , noConnect (100), inPrt1 (101) , inPrt2 (102) , inPrt3 (103) , inPrt4 (104) , inPrt5 (105) , inPrt6 (106) , inPrt7 (107) , inPrt8 (108) , inPrt9 (109) , inPrt10 (110) , inPrt11 (111) , inPrt12 (112) } " ::= {prtExPh1MlTsEntry 6} prtExPh1MlTsIConTs OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique time slot position. The valid time slots are 1..24 for T1 Card and 1..31 for E1 interface. In G732S-E1 lines time slot 16 is not valid for data, it is dedicated to multiframe synchronization and voice signaling." ::= {prtExPh1MlTsEntry 7} prtExPh1MlTsExt OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION "A pointer to an extension of this table: prtExTsSplitTable. - If prtExPh1MlTsIConSlot='split', its value should be set to the OBJECT IDENTIFIER of the prtExTsSplitTable, with its relevant CnfgIdx, SltIdx, PrtIdx, TsIdx and 1st TsBit. - If prtExPh1MlTsIConSlot is not 'split', its value should be set to the OBJECT IDENTIFIER { 0 0 }. " ::= { prtExPh1MlTsEntry 8 } prtExPh1MlTsTest OBJECT-TYPE SYNTAX INTEGER { none (1), localLoop (2), remoteLoop (3), remoteBert (8), -- BERT localToneInjection (9), -- Tone Injection remoteToneInjection (18), -- Backward Tone Injection localBert (30), split (254), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a test to be activated on the selected TS. It is applicable only when prtSTstCmd=testPerTS(31). notApplicable - when prtSTstCmd is NOT testPerTS(31). none - no test is applied for the selected TS. split - when the tests are per Bit of the selected TS." ::= { prtExPh1MlTsEntry 9 } prtExPh1MlTsType OBJECT-TYPE SYNTAX INTEGER { noConnect (2), data (3), voice (4), cas (5), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "The Time Slot Type. " ::= { prtExPh1MlTsEntry 10 } prtExPh1MlTsBundle OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The number of the bundle containing this Time Slot. If no bundle exists for this TS or the bundle number is irrelevant, the value will be 0." ::= { prtExPh1MlTsEntry 11 } prtExPh1MlTsTestDuration OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the maximum duration of executing a test on the specific TS. This entry applies to all the test operations. For the Vmux2100 the values are: 0 - 60 seconds. A zero value specifies no time limitation. When the test isn't active, the agent initiates this object to 2 when the duration is needed and to 0 if its not required. The user should set this parameter after setting the 'prtExPh1MlTsTest' parameter." ::= { prtExPh1MlTsEntry 12 } -- -- MPH.1/T1 & MPH.1/E1 -- Internal port objects table -- (only for the Hybrid modules) -- prtInPh1MlCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtInPh1MlCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= {prtPh1MlCnfg 3} prtInPh1MlCnfgEntry OBJECT-TYPE SYNTAX PrtInPh1MlCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtInPh1MlCnfgIdx, prtInPh1MlSltType, prtInPh1MlPrtIdx } ::= { prtInPh1MlCnfgTable 1} PrtInPh1MlCnfgEntry ::= SEQUENCE { prtInPh1MlCnfgIdx Integer32, prtInPh1MlSltType INTEGER, prtInPh1MlPrtIdx Integer32, prtInPh1MlConnect INTEGER, prtInPh1MlRate INTEGER, prtInPh1MlProtocol INTEGER, prtInPh1MlConnectionTyp INTEGER, prtInPh1MlCongResponse INTEGER, prtInPh1MlCongLevel Integer32, prtInPh1MlTc INTEGER, prtInPh1MlFlowControl INTEGER, prtInPh1MlSegment INTEGER, prtInPh1MlFrMngProt INTEGER, prtInPh1MlEnqPeriod Integer32, prtInPh1MlFullRptPeriod Integer32, prtInPh1MlFrWindowSize Integer32, prtInPh1MlErrorsThreshold Integer32, prtInPh1MlMaxIdleTime Integer32, prtInPh1MlBearerCh INTEGER, prtInPh1MlAssociatedExCh INTEGER, prtInPh1MlClockEncoding INTEGER, prtInPh1MlMinSeparators Integer32, prtInPh1MlCcittCrc INTEGER, prtInPh1MlFrameSeparator INTEGER } prtInPh1MlCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. " ::= { prtInPh1MlCnfgEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. prtInPh1MlSltType OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. For ISDN BRI port of MX300/30: io1(5) = isdn1(5) and io2(6) = isdn2(6) In the ?004 Unit the entries io6(10)..io12(16) are not valid" ::= { prtInPh1MlCnfgEntry 2} prtInPh1MlPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number. MPH.1/E1 and MPH.1/T1 cards have three internal interfaces. MX3000 modules may have up to 50 internal ports." ::= { prtInPh1MlCnfgEntry 3} prtInPh1MlConnect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port should be considered in any of the mux algorithms." ::= { prtInPh1MlCnfgEntry 4} prtInPh1MlRate OBJECT-TYPE SYNTAX INTEGER { r1x56eq56Kbps (1), r1x64eq64Kbps (2), r2x56eq112Kbps (3), r2x64eq128Kbps (4), r3x56eq168Kbps (5), r3x64eq192Kbps (6), r4x56eq224Kbps (7), r4x64eq256Kbps (8), r5x56eq280Kbps (9), r5x64eq320Kbps (10), r6x56eq336Kbps (11), r6x64eq384Kbps (12), r7x56eq392Kbps (13), r7x64eq448Kbps (14), r8x56eq448Kbps (15), r8x64eq512Kbps (16), r9x56eq504Kbps (17), r9x64eq576Kbps (18), r10x56eq560Kbps (19), r10x64eq640Kbps (20), r11x56eq616Kbps (21), r11x64eq704Kbps (22), r12x56eq672Kbps (23), r12x64eq768Kbps (24), r13x56eq728Kbps (25), r13x64eq832Kbps (26), r14x56eq784Kbps (27), r14x64eq896Kbps (28), r15x56eq840Kbps (29), r15x64eq960Kbps (30), r16x56eq896Kbps (31), r16x64eq1024Kbps(32), r17x56eq952Kbps (33), r17x64eq1088Kbps(34), r18x56eq1008Kbps(35), r18x64eq1152Kbps(36), r19x56eq1064Kbps(37), r19x64eq1216Kbps(38), r20x56eq1120Kbps(39), r20x64eq1280Kbps(40), r21x56eq1176Kbps(41), r21x64eq1344Kbps(42), r22x56eq1232Kbps(43), r22x64eq1408Kbps(44), r23x56eq1288Kbps(45), r23x64eq1472Kbps(46), r24x56eq1344Kbps(47), r24x64eq1536Kbps(48), -- the next values are only for MPH.1/E1 modules r25x56eq1400Kbps(49), r25x64eq1600Kbps(50), r26x56eq1456Kbps(51), r26x64eq1664Kbps(52), r27x56eq1512Kbps(53), r27x64eq1728Kbps(54), r28x56eq1568Kbps(55), r28x64eq1792Kbps(56), r29x56eq1624Kbps(57), r29x64eq1856Kbps(58), r30x56eq1680Kbps(59), r30x64eq1920Kbps(60), r31x56eq1736Kbps(61), r31x64eq1984Kbps(62), noRate (100) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the port speed. " ::= { prtInPh1MlCnfgEntry 5} prtInPh1MlProtocol OBJECT-TYPE SYNTAX INTEGER { fr (1), frPlus (2), pCellRelay (3), hdlcSdlc (4), transparentHdlc (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the applied protocol." ::= { prtInPh1MlCnfgEntry 6} prtInPh1MlConnectionTyp OBJECT-TYPE SYNTAX INTEGER { sameNetManaged (1), sameNetNotMana (2), user (3), otherNet (4), pubNet (5), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the link connection type. It is required for three reasons: FR/CR Inband management operation (LMI,CLMM...). CIR check. NMS network management. SameNetManaged - indicates network internal line. SameNetNotMana - indicates network internal line, but the remote mux is not managed by the nms. User - User to Network Interface. OtherNet - Network To Network Interfce. PubNet - Access Mux To PubNet Interface." ::= { prtInPh1MlCnfgEntry 7} prtInPh1MlCongResponse OBJECT-TYPE SYNTAX INTEGER { no (2), flowControl (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates how to handle the congestion indication to/from the mux internal connection side (for example transmit/receive becn to/from the network). no - do nothing FlowControl - translate the congestion indication between the port and the internal connection port according to the definition of the prtInPh1MlFlowControl parameters. The operation is done in both directions." ::= { prtInPh1MlCnfgEntry 8} prtInPh1MlCongLevel OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the level of delayed data in precents of the total available dynamic memory, for which the port will start to operate . The resolution of the parameter is 5 percent. Valid values: 10..70, 255. 255=notApplicable." ::= { prtInPh1MlCnfgEntry 9} prtInPh1MlTc OBJECT-TYPE SYNTAX INTEGER { tc1sec (1), tc2sec (2), tc3sec (3), tc4sec (4), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the Tc parameter which is the time period of the sliding window in which the Bc/Be are tested. The value of this parameter is identical for all the ports in the specific card. 255=notApplicable." ::= { prtInPh1MlCnfgEntry 10} prtInPh1MlFlowControl OBJECT-TYPE SYNTAX INTEGER { none (2), fecnBecn (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the required flow control betweeen the port and the remote equipment." ::= { prtInPh1MlCnfgEntry 11} prtInPh1MlSegment OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), s36Byte (2), s150Byte (3), s264Byte (4), s378Byte (5), s492Byte (6), s236Byte (7), s472Byte (8), s708Byte (9), s944Byte (10), s1180Byte (11) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is the Segmentation in Bytes. In protocol FR+, ISDN internals, MX 30/300 the segmentation is: 50 (2) ,158 (3) ,266 (4) ,376 (5), 484 (6) In MX 3000/4: For protocol FR+ (internal ISDN ports of MHS.S, MHS.U, MHS.E1, MHS.T1 cards) segmentation values are: 236 (7),472 (8), 708 (9), 944 (10) ,1180 (11)" ::= { prtInPh1MlCnfgEntry 12} prtInPh1MlFrMngProt OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), none (2), lmi (3), ansiT1 (4), --Annex D annexA (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the Frame-Relay management protocol. ansiT1 = ANSI T1.617 Annex D (this is the default value). This parameter is applicable only for FR and FR+ protocols. When prtInPh1MlConnectionTyp = sameNetManaged, this object will be RO (internally determined). " ::= { prtInPh1MlCnfgEntry 13} prtInPh1MlEnqPeriod OBJECT-TYPE SYNTAX Integer32 (0..30) MAX-ACCESS read-write STATUS current DESCRIPTION "This object is the Status Enquiry Period, in seconds. It determines the frequency of the Status Enquiry message as sent by the FR user side. At the FR network side, it determines the timeout for this message reception. Default = 4 seconds. This parameter is applicable only for FR and FR+ protocols AND only when prtInPh1MlFrMngProt is NOT (notApplicable or none). 0=notApplicable." ::= { prtInPh1MlCnfgEntry 14} prtInPh1MlFullRptPeriod OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "This object is the Full Report Frequency. It determines the number of the Status Enquiry messages sent by the FR user side, before a Full Report Request is sent. The units are : Status Enquiry messages (periods). Valid values: 1 .. 255. 255 = infinite (never sent). This parameter is applicable only for FR and FR+ protocols AND only when prtInPh1MlFrMngProt is NOT (notApplicable or none). 0=notApplicable." ::= { prtInPh1MlCnfgEntry 15} prtInPh1MlFrWindowSize OBJECT-TYPE SYNTAX Integer32 (0..10) MAX-ACCESS read-write STATUS current DESCRIPTION "This object is the FR Window Size. It determines the number of samplings in the sliding window that counts the errors. This parameter is applicable only for FR and FR+ protocols AND only when prtInPh1MlFrMngProt is NOT (notApplicable or none). 0=notApplicable." ::= { prtInPh1MlCnfgEntry 16} prtInPh1MlErrorsThreshold OBJECT-TYPE SYNTAX Integer32 (0..10) MAX-ACCESS read-write STATUS current DESCRIPTION "This object is the Max Errors. It determines the number of Status Enquiry Errors that occured within the FR sliding window, before this port is considered DOWN (threshold). This parameter is applicable only for FR and FR+ protocols AND only when prtInPh1MlFrMngProt is NOT (notApplicable or none). 0=notApplicable. " ::= { prtInPh1MlCnfgEntry 17} prtInPh1MlMaxIdleTime OBJECT-TYPE SYNTAX Integer32 (0..1800) MAX-ACCESS read-write STATUS current DESCRIPTION "Move to higher prioritized connected link after this period of seconds of silence on the current link. 0=Never. Never move to higher prioritized connected link. UNIT is seconds. Valid values are: 0, 1, 2, 3, 4, 5, 10, 20, 30, 40, 50, 60, 120, 180, 240, 300, 360, 420, 480, 540, 600, 900, 1200, 1500, 1800. Attempt to Set an invalid value will result in getting the default value." DEFVAL { 10 } ::= {prtInPh1MlCnfgEntry 18} prtInPh1MlBearerCh OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), channelB1 (3), channelB2 (4), chB1andchB2 (5), none (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Defines which B (bearer) channels are used for transferring ISDN data. Default value is: none (255). anyChannel (2) is skipped because it is not in use here." ::= {prtInPh1MlCnfgEntry 19} prtInPh1MlAssociatedExCh OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1), exPrt2 (2), exPrt3 (3), exPrt4 (4), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the external port associated to this internal port. At present, it is used by the Hybrid (mp2100h), MHS-4 cards which can have up to 64 dynamic internal ports associated with External ports. For ISDN cards, the value will be: notApplicable (255). The associated external of an ISDN internal port is represented by the MIB object: prtIsdnDirectoryPrtNu." ::= { prtInPh1MlCnfgEntry 20} prtInPh1MlClockEncoding OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), nrz (2), nrzI (3), fm0 (4), manchester (5), diffManchester(6) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is the Encoding type of the Line. This parameter is applicable only for FR and FR+ protocols." ::= { prtInPh1MlCnfgEntry 21} prtInPh1MlMinSeparators OBJECT-TYPE SYNTAX Integer32 (0..16) MAX-ACCESS read-write STATUS current DESCRIPTION "Minimum number of bytes separating between two adjacent frames (HDLC item). 0 = notApplicable" ::= { prtInPh1MlCnfgEntry 22} prtInPh1MlCcittCrc OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), crc16 (2), crc32 (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates how many Bits are used for CRC (HDLC item)." ::= { prtInPh1MlCnfgEntry 23} prtInPh1MlFrameSeparator OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), idles (2), flags (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates what should be transferred on the line when there are no frames to pass (HDLC item). idles: mean that FF will pass on the line flags: mean that 7E will pass on the line." ::= { prtInPh1MlCnfgEntry 24} -- -- MPH1.T1 & MPH1.E1 -- Internal port Dlci objects table -- prtInPh1MlDlciTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtInPh1MlDlciEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= {prtPh1MlCnfg 4} prtInPh1MlDlciEntry OBJECT-TYPE SYNTAX PrtInPh1MlDlciEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtInPh1MlDlciCnfgIdx, prtInPh1MlDlciSltIdx, prtInPh1MlDlciPrtIdx, prtInPh1MlDlciIdx } ::= { prtInPh1MlDlciTable 1} PrtInPh1MlDlciEntry ::= SEQUENCE { prtInPh1MlDlciCnfgIdx Integer32, prtInPh1MlDlciSltIdx INTEGER, prtInPh1MlDlciPrtIdx INTEGER, prtInPh1MlDlciIdx Integer32, prtInPh1MlDlciValid INTEGER, prtInPh1MlDlciIConSlt INTEGER, prtInPh1MlDlciIConPrt INTEGER, prtInPh1MlDlciIConDlci Integer32, prtInPh1MlDlciTxBc INTEGER, prtInPh1MlDlciTxBe INTEGER, prtInPh1MlDlciRxBc INTEGER, prtInPh1MlDlciRxBe INTEGER, prtInPh1MlDlciPriority Integer32, prtInPh1MlDlciStatus INTEGER } prtInPh1MlDlciCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. " ::= { prtInPh1MlDlciEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. prtInPh1MlDlciSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid" ::= { prtInPh1MlDlciEntry 2} prtInPh1MlDlciPrtIdx OBJECT-TYPE SYNTAX INTEGER { inPrt1 (101) , inPrt2 (102) , inPrt3 (103) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique internal port number. MPH.1/E1 and MPH.1/T1 cards have three internal ports." ::= { prtInPh1MlDlciEntry 3} prtInPh1MlDlciIdx OBJECT-TYPE SYNTAX Integer32 (1..991) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique index for each possible used dlci(16..991). When the protocol is not Multiplexing protocol, then its type is 'user' and the only valid index is 1." ::= { prtInPh1MlDlciEntry 4} prtInPh1MlDlciValid OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the attributes in this entry are valid or not. The user can add/delete pvc (dlci to dlci connection) by modifing this object" ::= { prtInPh1MlDlciEntry 5} prtInPh1MlDlciIConSlt OBJECT-TYPE SYNTAX INTEGER { noConnect(2), cl (3), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique slot position In the Mux (Agent) where the dlci is routed to. In the ?004 Unit the entries io6(10)..io16) are not valid" ::= { prtInPh1MlDlciEntry 6} prtInPh1MlDlciIConPrt OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) , exPrt7 (7) , exPrt8 (8) , exPrt9 (9) , exPrt10 (10) , clNMS (99) , noConnect (100), inPrt1 (101) , inPrt2 (102) , inPrt3 (103) , inPrt4 (104) , inPrt5 (105) , inPrt6 (106) , inPrt7 (107) , inPrt8 (108) , inPrt9 (109) , inPrt10 (110) , inPrt11 (111) , inPrt12 (112) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique port id which the dlci is routed to." ::= { prtInPh1MlDlciEntry 7} prtInPh1MlDlciIConDlci OBJECT-TYPE SYNTAX Integer32 (1..991) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique internal connection dlci number which the src dlci is routed to." ::= { prtInPh1MlDlciEntry 8} prtInPh1MlDlciTxBc OBJECT-TYPE SYNTAX INTEGER { full (1), zero (2), txBc9600bps (3), txBc14200bps (4), txBc19200bps (5), txBc28800bps (6), txBc32000bps (7), txBc38400bps (8), txBc48000bps (9), txBc56000bps (10), txBc57600bps (11), txBc64Kbps (12), txBc128Kbps (13), txBc192Kbps (14), txBc256Kbps (15), txBc320Kbps (16), txBc384Kbps (17), txBc448Kbps (18), txBc512Kbps (19), txBc768Kbps (20), txBc1024Kbps (21) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique Tx committed bandwidth on the user transmit line or at the port receive line." ::= { prtInPh1MlDlciEntry 9} prtInPh1MlDlciTxBe OBJECT-TYPE SYNTAX INTEGER { full (1), zero (2), txBe9600bps (3), txBe14200bps (4), txBe19200bps (5), txBe28800bps (6), txBe32000bps (7), txBe38400bps (8), txBe48000bps (9), txBe56000bps (10), txBe57600bps (11), txBe64Kbps (12), txBe128Kbps (13), txBe192Kbps (14), txBe256Kbps (15), txBe320Kbps (16), txBe384Kbps (17), txBe448Kbps (18), txBe512Kbps (19), txBe768Kbps (20), txBe1024Kbps (21) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique Tx excess bandwidth on the user transmit line or at the port receive line." ::= { prtInPh1MlDlciEntry 10} prtInPh1MlDlciRxBc OBJECT-TYPE SYNTAX INTEGER { full (1), zero (2), rxBc9600bps (3), rxBc14200bps (4), rxBc19200bps (5), rxBc28800bps (6), rxBc32000bps (7), rxBc38400bps (8), rxBc48000bps (9), rxBc56000bps (10), rxBc57600bps (11), rxBc64Kbps (12), rxBc128Kbps (13), rxBc192Kbps (14), rxBc256Kbps (15), rxBc320Kbps (16), rxBc384Kbps (17), rxBc448Kbps (18), rxBc512Kbps (19), rxBc768Kbps (20), rxBc1024Kbps (21) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique Rx committed bandwidth on the user receive line or at the port transmit line." ::= { prtInPh1MlDlciEntry 11} prtInPh1MlDlciRxBe OBJECT-TYPE SYNTAX INTEGER { full (1), zero (2), rxBe9600bps (3), rxBe14200bps (4), rxBe19200bps (5), rxBe28800bps (6), rxBe32000bps (7), rxBe38400bps (8), rxBe48000bps (9), rxBe56000bps (10), rxBe57600bps (11), rxBe64Kbps (12), rxBe128Kbps (13), rxBe192Kbps (14), rxBe256Kbps (15), rxBe320Kbps (16), rxBe384Kbps (17), rxBe448Kbps (18), rxBe512Kbps (19), rxBe768Kbps (20), rxBe1024Kbps (21) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique Rx excess bandwidth on the user receive line or at the port transmit line." ::= { prtInPh1MlDlciEntry 12} prtInPh1MlDlciPriority OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique priority of the pcv. 1 is the lowest priority and 8 is the highest priority." ::= { prtInPh1MlDlciEntry 13} prtInPh1MlDlciStatus OBJECT-TYPE SYNTAX INTEGER { disconnected (1), connected (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the status of the pvc. The status is disconnected(1) when one of the sides is programmed as not connected" ::= { prtInPh1MlDlciEntry 14} -- -- ML-20 - High Speed Main Link card -- External Port Objects -- prtPhMlCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtPhMlCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= {prtPh1MlCnfg 5} prtPhMlCnfgEntry OBJECT-TYPE SYNTAX PrtPhMlCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtPhMlCnfgIdx, prtPhMlSltIdx, prtPhMlPrtIdx } ::= { prtPhMlCnfgTable 1} PrtPhMlCnfgEntry ::= SEQUENCE { prtPhMlCnfgIdx Integer32, prtPhMlSltIdx INTEGER, prtPhMlPrtIdx INTEGER, prtPhMlConnect INTEGER, prtPhMlRate INTEGER, prtPhMlCAS INTEGER, prtPhMlClockMode INTEGER, prtPhMlSatBuffer INTEGER, prtPhMlDialProcess INTEGER, prtPhMlSyncRestore Integer32, prtPhMlBus INTEGER, prtPhMlMfSyncSlot INTEGER } prtPhMlCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. " ::= { prtPhMlCnfgEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. prtPhMlSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the module is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid." ::= { prtPhMlCnfgEntry 2} prtPhMlPrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number. ML-20 cards have just one external interface." ::= { prtPhMlCnfgEntry 3} prtPhMlConnect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port should be considered in any of the mux algorithms." ::= {prtPhMlCnfgEntry 4} prtPhMlRate OBJECT-TYPE SYNTAX INTEGER { r2x64eq128Kbps (4), r3x64eq192Kbps (6), r4x64eq256Kbps (8), r5x64eq320Kbps (10), r6x64eq384Kbps (12), r7x64eq448Kbps (14), r8x64eq512Kbps (16), r9x64eq576Kbps (18), r10x64eq640Kbps (20), r11x64eq704Kbps (22), r12x64eq768Kbps (24), r13x64eq832Kbps (26), r14x64eq896Kbps (28), r15x64eq960Kbps (30), r16x64eq1024Kbps(32), r17x64eq1088Kbps(34), r18x64eq1152Kbps(36), r19x64eq1216Kbps(38), r20x64eq1280Kbps(40), r21x64eq1344Kbps(42), r22x64eq1408Kbps(44), r23x64eq1472Kbps(46), r24x64eq1536Kbps(48), r25x64eq1600Kbps(50), r26x64eq1664Kbps(52), r27x64eq1728Kbps(54), r28x64eq1792Kbps(56), r29x64eq1856Kbps(58), r30x64eq1920Kbps(60), r31x64eq1984Kbps(62) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the port speed." ::= {prtPhMlCnfgEntry 5} prtPhMlCAS OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether Channel Associated Signaling (CAS) is used." ::= {prtPhMlCnfgEntry 6} prtPhMlClockMode OBJECT-TYPE SYNTAX INTEGER { dce (2), ext-dce (3), dte (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Clock mode." ::= { prtPhMlCnfgEntry 7} prtPhMlSatBuffer OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Satellite Buffer (+/- 256)." ::= {prtPhMlCnfgEntry 8} prtPhMlDialProcess OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), no (2), callIn (3), callOut (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Dial Process." ::= {prtPhMlCnfgEntry 9} prtPhMlSyncRestore OBJECT-TYPE SYNTAX Integer32 (0..10) MAX-ACCESS read-write STATUS current DESCRIPTION "Sync Restoration time, in seconds. notApplicable=0. " ::= {prtPhMlCnfgEntry 10} prtPhMlBus OBJECT-TYPE SYNTAX INTEGER { none (1), busA (2), busB (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The TDM BUS this port is linked to." ::= {prtPhMlCnfgEntry 11} prtPhMlMfSyncSlot OBJECT-TYPE SYNTAX INTEGER { none (2), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the sync is synchronized according to a certain card and the slot of this card. This operation is required in order to bypass signaling of PCM voice channels. In the ?004 Unit the entries io6(10)..io12(16) are not valid" ::= {prtPhMlCnfgEntry 12} -- This table is an extension for new version of MAXcess -- modules. prtLogicalCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtLogicalCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= {prtLogicalCnfg 1} prtLogicalCnfgEntry OBJECT-TYPE SYNTAX PrtLogicalCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtLogicalCnfgIdx, prtLogicalSltIdx, prtLogicalPrtIdx } ::= { prtLogicalCnfgTable 1} PrtLogicalCnfgEntry ::= SEQUENCE { prtLogicalCnfgIdx Integer32, prtLogicalSltIdx INTEGER, prtLogicalPrtIdx Integer32, prtLogicalConnect INTEGER, prtLogicalFunction INTEGER, prtLogicalRowStatus RowStatus } prtLogicalCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. " ::= { prtLogicalCnfgEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. prtLogicalSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Slot Index. For ISDN BRI Ports of MX300/30, io1(5) = isdn1(5) and io2(6) = isdn2(6)." ::= { prtLogicalCnfgEntry 2} prtLogicalPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number. This port number should be an internal port number: inPrt1(101)->inPrt50(150), linkSel1(200)->linkSel50(250), encaps1(300)-> encaps50(350), huntGr1(101) -> huntGr10(110)." ::= { prtLogicalCnfgEntry 3} prtLogicalConnect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute indicates whether the port should be considered in any of the mux algorithms." ::= { prtLogicalCnfgEntry 4} prtLogicalFunction OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), linkSelector(2), encapsulator(3), huntGroup(4) } MAX-ACCESS read-create STATUS current DESCRIPTION "This parameter defines the function of the relevant channel." ::= { prtLogicalCnfgEntry 5 } prtLogicalRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This parameter allows the NMS to create/delete logical ports. The only possible supported RowStatus vaules are active (1) and destroy (6)." ::= { prtLogicalCnfgEntry 6 } -- This group contains management information for the -- link selector function. linkSelectorCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF LinkSelectorCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= { prtLogicalCnfg 2} linkSelectorCnfgEntry OBJECT-TYPE SYNTAX LinkSelectorCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {linkSelectorCnfgIdx, linkSelectorSltIdx, linkSelectorPrtIdx } ::= { linkSelectorCnfgTable 1} LinkSelectorCnfgEntry ::= SEQUENCE { linkSelectorCnfgIdx Integer32, linkSelectorSltIdx INTEGER, linkSelectorPrtIdx Integer32, linkSelectorMaxIdleTime Integer32, linkSelectorMode INTEGER, linkSelectorRevert INTEGER, linkSelectorMinBUSession Integer32 } linkSelectorCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. " ::= { linkSelectorCnfgEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. linkSelectorSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Slot Index" ::= { linkSelectorCnfgEntry 2} linkSelectorPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number. This port number should be internal port number: higher or equal to linkSeL1(201)." ::= { linkSelectorCnfgEntry 3} linkSelectorMaxIdleTime OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "Move to higher prioritized connected link after this period of seconds of silence on the current link. 0=move immediately to higher prioritized connected link. UNIT is seconds." DEFVAL { 0 } ::= {linkSelectorCnfgEntry 4} linkSelectorMode OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), backup(2), bod(3) } MAX-ACCESS read-write STATUS current DESCRIPTION " If the link selector is in mode: backup(2)=then the link with the lower priority will be used in case of failure of the higher priority link, bod(3)=bandwidth on demand or dynamic bandwidth allocation means that links with lower priority will be used whenever additional bandwidth is required. " DEFVAL { backup } ::= {linkSelectorCnfgEntry 5} linkSelectorRevert OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), auto(2), manual(3) } MAX-ACCESS read-write STATUS current DESCRIPTION " If the link selector is in mode backup: auto(2)=return automatically to Main link when it is OK. manual(3)=stays connected to backup link." DEFVAL { auto } ::= {linkSelectorCnfgEntry 6} linkSelectorMinBUSession OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-write STATUS current DESCRIPTION "Minimum duration of a backup session before returning to Main Link. Relevant in Backup Mode and when Revert is auto(2). Value 255 is for NEVER which means never return to Main Link. UNIT is minutes." DEFVAL { 10 } ::= {linkSelectorCnfgEntry 7} -- Prioritized Links linkSelectorPLinkTable OBJECT-TYPE SYNTAX SEQUENCE OF LinkSelectorPLinkEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= { prtLogicalCnfg 3} linkSelectorPLinkEntry OBJECT-TYPE SYNTAX LinkSelectorPLinkEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {pLinkCnfgIdx, pLinkSltIdx, pLinkPrtIdx, pLinkIdx } ::= { linkSelectorPLinkTable 1} LinkSelectorPLinkEntry ::= SEQUENCE { pLinkCnfgIdx Integer32, pLinkSltIdx INTEGER, pLinkPrtIdx Integer32, pLinkIdx Integer32, pLinkSlotNu INTEGER, pLinkPortNu Integer32, pLinkPrioNu Integer32, pLinkVRate INTEGER } pLinkCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. " ::= { linkSelectorPLinkEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. pLinkSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Slot Index" ::= { linkSelectorPLinkEntry 2} pLinkPrtIdx OBJECT-TYPE SYNTAX Integer32(200..250) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number. This port number should be the link selector number." ::= { linkSelectorPLinkEntry 3} pLinkIdx OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "This index is the row number." ::= { linkSelectorPLinkEntry 4} pLinkSlotNu OBJECT-TYPE SYNTAX INTEGER { noConnect (2), cl(3), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "The slot of the prioritized link. For ISDN BRI ports of MX300/30, io1(5) = isdn1(5) and io2(6) = isdn2(6)." DEFVAL { noConnect } ::= { linkSelectorPLinkEntry 5 } pLinkPortNu OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The port of the prioritized link. Value 100 is for noConnect." DEFVAL { 100 } ::= { linkSelectorPLinkEntry 6 } pLinkPrioNu OBJECT-TYPE SYNTAX Integer32(1..8) MAX-ACCESS read-write STATUS current DESCRIPTION "The priority of the prioritized link. MIN=1...., MAX=8." ::= { linkSelectorPLinkEntry 7 } pLinkVRate OBJECT-TYPE SYNTAX INTEGER { r1x56eq56Kbps (1), r1x64eq64Kbps (2), r2x56eq112Kbps (3), r2x64eq128Kbps (4), r3x56eq168Kbps (5), r3x64eq192Kbps (6), r4x56eq224Kbps (7), r4x64eq256Kbps (8), r5x56eq280Kbps (9), r5x64eq320Kbps (10), r6x56eq336Kbps (11), r6x64eq384Kbps (12), r7x56eq392Kbps (13), r7x64eq448Kbps (14), r8x56eq448Kbps (15), r8x64eq512Kbps (16), r9x56eq504Kbps (17), r9x64eq576Kbps (18), r10x56eq560Kbps (19), r10x64eq640Kbps (20), r11x56eq616Kbps (21), r11x64eq704Kbps (22), r12x56eq672Kbps (23), r12x64eq768Kbps (24), r13x56eq728Kbps (25), r13x64eq832Kbps (26), r14x56eq784Kbps (27), r14x64eq896Kbps (28), r15x56eq840Kbps (29), r15x64eq960Kbps (30), r16x56eq896Kbps (31), r16x64eq1024Kbps(32), r17x56eq952Kbps (33), r17x64eq1088Kbps(34), r18x56eq1008Kbps(35), r18x64eq1152Kbps(36), r19x56eq1064Kbps(37), r19x64eq1216Kbps(38), r20x56eq1120Kbps(39), r20x64eq1280Kbps(40), r21x56eq1176Kbps(41), r21x64eq1344Kbps(42), r22x56eq1232Kbps(43), r22x64eq1408Kbps(44), r23x56eq1288Kbps(45), r23x64eq1472Kbps(46), r24x56eq1344Kbps(47), r24x64eq1536Kbps(48), r25x56eq1400Kbps(49), r25x64eq1600Kbps(50), r26x56eq1456Kbps(51), r26x64eq1664Kbps(52), r27x56eq1512Kbps(53), r27x64eq1728Kbps(54), r28x56eq1568Kbps(55), r28x64eq1792Kbps(56), r29x56eq1624Kbps(57), r29x64eq1856Kbps(58), r30x56eq1680Kbps(59), r30x64eq1920Kbps(60), r31x56eq1736Kbps(61), r31x64eq1984Kbps(62), noRate(100) } MAX-ACCESS read-write STATUS current DESCRIPTION "The rate to use with this link." DEFVAL { noRate } ::= { linkSelectorPLinkEntry 8 } -- -- Megaplex or Kilomux ?000/?004 MPH.1/3 High speed packet data cards. -- Megaplex or Kilomux ?000/?004 MPL.6 Low speed packet data cards. -- (Mph1, Mph3, Mpl6) -- Maxcess 3000/3004 MLS-3/6, MHS-1/3 -- -- prtExPhPlCnfgTable OBJECT IDENTIFIER ::= {prtPhPlCnfg 1} -- prtExPhPlDlciTable OBJECT IDENTIFIER ::= {prtPhPlCnfg 2} -- prtExPhPlModemTable OBJECT IDENTIFIER ::= {prtPhPlCnfg 3} -- Mph.1 Mph.3 Mpl.6/ Kphs.1 Kphs.3 Mls.3 Mls.6 Mhs.1 Mhs.3 -- External port objects table prtExPhPlCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtExPhPlCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= {prtPhPlCnfg 1} prtExPhPlCnfgEntry OBJECT-TYPE SYNTAX PrtExPhPlCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtExPhPlCnfgIdx, prtExPhPlSltIdx, prtExPhPlPrtIdx} ::= { prtExPhPlCnfgTable 1} PrtExPhPlCnfgEntry ::= SEQUENCE { prtExPhPlCnfgIdx Integer32, prtExPhPlSltIdx INTEGER, prtExPhPlPrtIdx INTEGER, prtExPhPlConnect INTEGER, prtExPhPlHRate INTEGER, prtExPhPlLRate INTEGER, prtExPhPlProtocol INTEGER, prtExPhPlConnectionTyp INTEGER, prtExPhPlClkMode INTEGER, prtExPhPlDceClkSrc INTEGER, prtExPhPlCongResponse INTEGER, prtExPhPlCongLevel Integer32, prtExPhPlTc INTEGER, prtExPhPlFlowControl INTEGER, prtExPhPlDcdRts INTEGER, prtExPhPlDcdRtsControlPath INTEGER, prtExPhPlDataBits INTEGER, prtExPhPlParity INTEGER, prtExPhPlStopBits INTEGER, prtExPhPlLXon Integer32, prtExPhPlLXoff Integer32, prtExPhPlFrMngProt INTEGER, prtExPhPlEnqPeriod Integer32, prtExPhPlFullRptPeriod Integer32, prtExPhPlFrWindowSize Integer32, prtExPhPlErrorsThreshold Integer32, prtExPhPlPvcCreateMsg INTEGER, prtExPhPlCllmMsg INTEGER, prtExPhPlProtDelayLevel INTEGER, prtExPhPlClockEncoding INTEGER, prtExPhPlMinSeparators Integer32, prtExPhPlCcittCrc INTEGER, prtExPhPlFrameSeparator INTEGER, prtExPhPlIdleCode Integer32, prtExPhPlJitter Integer32 } prtExPhPlCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. " ::= { prtExPhPlCnfgEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. prtExPhPlSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid" ::= { prtExPhPlCnfgEntry 2} prtExPhPlPrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number. In case of PH.1 card, only exPrt(1) is valid." ::= { prtExPhPlCnfgEntry 3} prtExPhPlConnect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port should be considered in any of the mux algorithms." ::= { prtExPhPlCnfgEntry 4} prtExPhPlHRate OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), r32KbpsNLE (2), r48KbpsNLE (3), r56KbpsNLE (4), r64KbpsNLE (5), r112KbpsNLE (6), r128KbpsNLE (7), r168KbpsNLE (8), r192KbpsNLE (9), r224KbpsNLE (10), r256KbpsNLE (11), r280KbpsE (12), r320KbpsE (13), r336KbpsNLE (14), r384KbpsNLE (15), r392KbpsE (16), r448KbpsNLE (17), r504KbpsLE (18), -- r504KbpsE r512KbpsE (19), -- r512KbpsNLE r560KbpsE (20), r576KbpsLE (21), -- r576KbpsE r616KbpsE (22), r640KbpsE (23), r672KbpsNLE (24), r704KbpsE (25), r728KbpsE (26), r768KbpsNLE (27), r784KbpsE (28), r832KbpsE (29), r840KbpsE (30), r896KbpsNLE (31), r952KbpsE (32), r960KbpsE (33), r1008KbpsLE (34), -- r1008KbpsE r1024KbpsE (35), -- r1024KbpsNLE r1064KbpsE (36), r1088KbpsE (37), r1120KbpsE (38), r1152KbpsLE (39), -- r1152KbpsE r1176KbpsE (40), r1216KbpsE (41), r1232KbpsE (42), r1280KbpsE (43), r1288KbpsE (44), r1344KbpsNLE (45), r1400KbpsE (46), r1408KbpsE (47), r1456KbpsE (48), r1472KbpsE (49), r1512KbpsE (50), r1536KbpsE (51), -- r1536KbpsNLE r1568KbpsE (52), r1600KbpsE (53), r1624KbpsE (54), r1664KbpsE (55), r1680KbpsE (56), r1728KbpsE (57), r1736KbpsE (58), r1792KbpsNLE (59), r1856KbpsE (60), r1920KbpsE (61), r1984KbpsE (62), r2048KbpsE (63), -- r2048KbpsNLE -- -- Additional rates for: MAXcess, MP2100h -- r9d6KbpsNLE (65), r14d4KbpsNLE (66), r16KbpsNLE (67), r19d2KbpsNLE (68), r28d8KbpsNLE (69), r38d4KbpsNLE (70), r57d6KbpsNLE (71), -- For Mx 30/300 Only r115d2KbpsNLE (72), -- For Mx 30/300 Only r24000bps (73) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the port speed for HIGH speed cards. The card has limitations about the maximum sigma channel speeds and about the possible rates for each clock mode . N - The rate is valid for DCE and EXT-DCE Nodal clock mode. L - The rate is valid for DCE and EXT-DCE Local clock mode. E - The rate is valid for DTE External clock mode. 'r9d6KbpsNLE' means rate of 9.6 Kbps ('d'=dot). Note: Some rate attributes have been changed. As the MIB was already released with the old attributes, the names of the options were not changed. The new names + attributes are in a comment. Example: r2048KbpsE (63), -- r2048KbpsNLE" ::= { prtExPhPlCnfgEntry 5} prtExPhPlLRate OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), r300bpsNLE (2), r600bpsNLE (3), r800bpsNLE (4), r1200bpsNLE (5), r2400bpsNLE (6), r4800bpsNLE (7), r9600bpsNLE (8), r14400bpsLE (9), -- r14400bpsNLE r19200bpsNLE (10), r28800bpsLE (11), -- r28800bpsNLE r32000bpsNLE (12), r38400bpsNLE (13), r48000bpsNLE (14), r56000bpsNLE (15), r57600bpsLE (16), -- r57600bpsNLE r64000bpsNLE (17), r112000bps (18), -- For Mx 30/300 Only: r112000bpsNLE r115200bps (19), -- For Mx 30/300 Only: r115200bpsNLE -- -- additional rates -- r16000bpsNLE (20), r100bpsNLE (21), -- For Mx 30/300 Only r128000bps (22), -- For Mx 30/300 Only r24000bps (23) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the port speed for LOW speed cards. The card has limitations about the possible rates for each clock mode. N - The rate is valid for DCE and EXT-DCE Nodal clock mode. L - The rate is valid for DCE and EXT-DCE Local clock mode. E - The rate is valid for DTE External clock mode. Note: Some rate attributes have been changed. As the MIB was already released with the old attributes, the names of the options were not changed. The new names + attributes are in a comment. Example: r57600bpsLE (16), -- r57600bpsNLE " ::= { prtExPhPlCnfgEntry 6} prtExPhPlProtocol OBJECT-TYPE SYNTAX INTEGER { fr (1), frPlus (2), pCellRelay (3), hdlcSdlc (4), transparentHdlc (5), async (6), asyncReliable (7), activePPP (8), slip (9), pppAgent (10), slipAgent (11), transparent (12), sna (13) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the applied protocol." ::= { prtExPhPlCnfgEntry 7} prtExPhPlConnectionTyp OBJECT-TYPE SYNTAX INTEGER { sameNetManaged (1), sameNetNotMana (2), user (3), otherNet (4), pubNet (5), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the link connection type. It is required for three reasons: FR/CR Inband management opration (LMI,CLMM...). CIR check. NMS network management. SameNetManaged - indicates network internal line. SameNetMotMana - indicates network internal line, but the remote mux is not managed by the NMS. User - User to Network Interface. OtherNet - Network To Network Interface. PubNet - Access Mux To PubNet Interface." ::= { prtExPhPlCnfgEntry 8} prtExPhPlClkMode OBJECT-TYPE SYNTAX INTEGER { dce (1), extDce (2), dte (3), int (4), lbt (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Clock mode." ::= { prtExPhPlCnfgEntry 9} prtExPhPlDceClkSrc OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), local (2), nodalTiming (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the source of the clock when working in dce or ext-dce clock mode. notApplicable(1) - is applied for dte(3) and lbt(5) clock modes. When clock mode is dte, the clock source is always external, therefore this object's value is notApplicable. local(2) and nodalTiming(3) - are valid in dce(1), extDce(2) or int(4) clock modes. The recommended clock source is local(2)." ::= { prtExPhPlCnfgEntry 10} prtExPhPlCongResponse OBJECT-TYPE SYNTAX INTEGER { no (2), flowControl (3), -- duplex, to/from flow control toFlowControl (4) -- simplex , only to flow control } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates how to handle the congestion indication to/from the mux internal connection side (for example transmit/received becn to/from the network). no - do nothing flowControl - translates the congestion indication between the port and the internal connection port according to the definition of the prtInPh1MlFlowControl parameters. The operation is done on both directions. toFlowControl- translates the backward congestion indication received from the internal connection port (normally the network side) to flow control and do nothing in the other direction." ::= { prtExPhPlCnfgEntry 11} prtExPhPlCongLevel OBJECT-TYPE SYNTAX Integer32 (0..70) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the level of delayed data in precents of total available dynamic memory, for which the port will start to operate as congested. The resolution of the parameter is 5 percent." ::= { prtExPhPlCnfgEntry 12} prtExPhPlTc OBJECT-TYPE SYNTAX INTEGER { tc1sec (1), tc2sec (2), tc3sec (3), tc4sec (4), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the Tc parameter which is the time period of the sliding window in which the Bc/Be are tested. The value of this parameter is identical for all the ports of a specific card ." ::= { prtExPhPlCnfgEntry 13} prtExPhPlFlowControl OBJECT-TYPE SYNTAX INTEGER { none (2), fecnBecn (3), xonXoff (4), dtrCts (5), speedReduction (6) -- simplex response only congestion to flow control } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the required flow control betweeen the port and the remote equipment. fecnBecn - is valid only for FR, FR+ and CR protocols. xonXoff,dtrCts - are valid only for Async protocols. speedReduction - is valid only for DLC protocol when the Clock Mode is DCE and the Clock Source is Local." ::= { prtExPhPlCnfgEntry 14} prtExPhPlDcdRts OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), on (2), endToEnd (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Protocol may require end to end connect indication over the network. End to end link connection establishment over the FR network will be indicated to the user by using DCD or RTS control signals, depending on the clock mode: DCE or DTE respectively. The options are : - On : DCD(DCE)/RTS(DTE) will be constantly ON no matter if the End to End connection is established or not. - End to End: The DCD(DCE)/RTS(DTE) will be according to the status of the End to End connection." ::= { prtExPhPlCnfgEntry 15} prtExPhPlDcdRtsControlPath OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), off (2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Protocol may require end to end connect indication over the network. This parameter defines whether to take the user connection status (RTS(DCE)/DCD(DTE)) and forward it to the network side. - on : Transmit active connection to the network regardless the RTS/DCD control lines status. - off: Transmit active connection to the network according to the status of the RTS/DCD pin. " ::= { prtExPhPlCnfgEntry 16} prtExPhPlDataBits OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), dataBits7Bits (2), dataBits8Bits (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the number of data bits in async frame. It is relevant only for Async protocols." ::= { prtExPhPlCnfgEntry 17} prtExPhPlParity OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), odd (2), even (3), none (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the parity operation mode in async frame. It is relevant only for Async protocols." ::= { prtExPhPlCnfgEntry 18} prtExPhPlStopBits OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), sb1Bit (2), sb1dot5Bits (3), sb2Bits (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the minimum number of stop bits in the tx async frame. It is relevant only for Async protocols." ::= { prtExPhPlCnfgEntry 19} prtExPhPlLXon OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the character used as X-On to notify receive enable. This parameter is valid only for async protocols. Valid values: 0..255. The value 256 indicates that it's not applicable " ::= { prtExPhPlCnfgEntry 20} prtExPhPlLXoff OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the character used as X-Off to notify receive disable. This parameter is valid only for async protocols. Valid values: 0..255. The value 256 indicates that it's not applicable " ::= { prtExPhPlCnfgEntry 21} prtExPhPlFrMngProt OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), none (2), lmi (3), ansiT1 (4), --Annex D annexA (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the Frame-Relay management protocol. ansiT1 = ANSI T1.617 Annex D (this is the default value). This parameter is applicable only for FR and FR+ protocols. When prtExPhPlConnectionTyp = sameNetManaged, this object will be RO (internally determined). " ::= { prtExPhPlCnfgEntry 22} prtExPhPlEnqPeriod OBJECT-TYPE SYNTAX Integer32 (1..30) MAX-ACCESS read-write STATUS current DESCRIPTION "This object is the Status Enquiry Period, in seconds. It determines the frequency of the Status Enquiry message as sent by the FR user side. At the FR network side, it determines the timeout for this message reception. Default = 4 seconds. This parameter is applicable only for FR and FR+ protocols AND only when prtExPhPlFrMngProt is NOT (notApplicable or none)." ::= { prtExPhPlCnfgEntry 23} prtExPhPlFullRptPeriod OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-write STATUS current DESCRIPTION "This object is the Full Report Frequency. It determines the number of the Status Enquiry messages sent by the FR user side, before a Full Report Request is sent. The units are : Status Enquiry messages (periods). Valid values: 1 .. 255. 255 = infinite. This parameter is applicable only for FR and FR+ protocols AND only when prtExPhPlFrMngProt is NOT (notApplicable or none)." ::= { prtExPhPlCnfgEntry 24} prtExPhPlFrWindowSize OBJECT-TYPE SYNTAX Integer32 (1..10) MAX-ACCESS read-write STATUS current DESCRIPTION "This object is the FR Window Size. It determines the number of samplings in the sliding window that counts the errors. This parameter is applicable only for FR and FR+ protocols AND only when prtExPhPlFrMngProt is NOT (notApplicable or none)." ::= { prtExPhPlCnfgEntry 25} prtExPhPlErrorsThreshold OBJECT-TYPE SYNTAX Integer32 (1..10) MAX-ACCESS read-write STATUS current DESCRIPTION "This object is the Max Errors. It determines the number of Status Enquiry Errors that occured within the FR sliding window, before this port is considered DOWN (threshold). This parameter is applicable only for FR and FR+ protocols AND only when prtExPhPlFrMngProt is NOT (notApplicable or none)." ::= { prtExPhPlCnfgEntry 26} prtExPhPlPvcCreateMsg OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is Update Message (if required or not). It determines whether a message of a New PVC Creation is requested or not (yes/no). Default = no. This parameter is applicable only for FR and FR+ protocols AND only when prtExPhPlFrMngProt is NOT (notApplicable or none)." ::= { prtExPhPlCnfgEntry 27} prtExPhPlCllmMsg OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is CLLM Message (if required or not). It determines whether to send (or not) a congestion message when the port is Rx congested. Default = no. This parameter is applicable only for FR and FR+ protocols AND only when prtExPhPlFrMngProt is NOT (notApplicable or none)." ::= { prtExPhPlCnfgEntry 28} prtExPhPlProtDelayLevel OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), s36Byte (2), --level 1 s150Byte (3), --level 2 s264Byte (4), --level 3 s378Byte (5), --level 4 s492Byte (6) --level 5 } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is the Segmentation in Bytes. In some cases, the enumerated values will mean other segmentation values than specified: Product: MX-3000 MX-3000 MX-300/MX-30 Protocol: FR+ Transparent FR+ ----------------------------------------------------- level 1 50 Bytes 44 Bytes 50 Bytes level 2 158 Bytes 155 Bytes 158 Bytes level 3 266 Bytes 266 Bytes 266 Bytes level 4 376 Bytes 377 Bytes 376 Bytes level 5 484 Bytes 488 Bytes 484 Bytes Defval=level 1 value This parameter is applicable only for FR+ and transparent protocols." ::= { prtExPhPlCnfgEntry 29} prtExPhPlClockEncoding OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), nrz (2), nrzI (3), fm0 (4), manchester (5), diffManchester(6), nrzISpace (7), nrzIMark (8) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is the Encoding type of the Line. This parameter is applicable only for FR and FR+ protocols. For MAXCESS 3000 & MP2100H: when setting to nrzI (3) the nrzI works as nrzI Mark. For MAXCESS 30/300 when setting to nrzI (3) the nrzI works as nrzI Space." ::= { prtExPhPlCnfgEntry 30} prtExPhPlMinSeparators OBJECT-TYPE SYNTAX Integer32 (0..16) MAX-ACCESS read-write STATUS current DESCRIPTION "Minimum number of bytes separating between two adjacent frames (HDLC item). 0 = notApplicable" ::= { prtExPhPlCnfgEntry 31} prtExPhPlCcittCrc OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), crc16 (2), crc32 (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates how many Bits are used for CRC (HDLC item)." ::= { prtExPhPlCnfgEntry 32} prtExPhPlFrameSeparator OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), idles (2), flags (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates what should be transferred on the line when there are no frames to pass (HDLC item). idles: mean that FF will pass on the line flags: mean that 7E will pass on the line." ::= { prtExPhPlCnfgEntry 33} prtExPhPlIdleCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Determines the code for transmission when there are no frames to transmit on the line. The value should be 0 to FFH." ::= { prtExPhPlCnfgEntry 34} prtExPhPlJitter OBJECT-TYPE SYNTAX Integer32 (0..1000) MAX-ACCESS read-write STATUS current DESCRIPTION "Maximum variant delay of the FR network, in msec." ::= { prtExPhPlCnfgEntry 35} -- -- PH.1 & PH.3 -- External port Dlci table -- prtExPhPlDlciTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtExPhPlDlciEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only at the TmpCnfg entry." ::= {prtPhPlCnfg 2} prtExPhPlDlciEntry OBJECT-TYPE SYNTAX PrtExPhPlDlciEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtExPhPlDlciCnfgIdx, prtExPhPlDlciSltIdx, prtExPhPlDlciPrtIdx, prtExPhPlDlciIdx } ::= { prtExPhPlDlciTable 1} PrtExPhPlDlciEntry ::= SEQUENCE { prtExPhPlDlciCnfgIdx Integer32, prtExPhPlDlciSltIdx INTEGER, prtExPhPlDlciPrtIdx INTEGER, prtExPhPlDlciIdx Integer32, prtExPhPlDlciValid INTEGER, prtExPhPlDlciIConSlt INTEGER, prtExPhPlDlciIConPrt INTEGER, prtExPhPlDlciIConDlci Integer32, prtExPhPlDlciTxBc INTEGER, prtExPhPlDlciTxBe INTEGER, prtExPhPlDlciRxBc INTEGER, prtExPhPlDlciRxBe INTEGER, prtExPhPlDlciPriority Integer32, prtExPhPlDlciStatus INTEGER } prtExPhPlDlciCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. " ::= { prtExPhPlDlciEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. prtExPhPlDlciSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid" ::= { prtExPhPlDlciEntry 2} prtExPhPlDlciPrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique internal port number. PH.1/E1 and PH.1/T1 cards have three internal ports. Stand-alone units may have six such ports." ::= { prtExPhPlDlciEntry 3} prtExPhPlDlciIdx OBJECT-TYPE SYNTAX Integer32 (1..991) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique index for each possible used dlci(16..991). When the protocol is not Multiplexing protocol, its type is 'user' and the only valid index is 1." ::= { prtExPhPlDlciEntry 4} prtExPhPlDlciValid OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the attributes in this entry are valid or not. The user can add/delete pvc (dlci to dlci connection) by modifing this object" ::= { prtExPhPlDlciEntry 5} prtExPhPlDlciIConSlt OBJECT-TYPE SYNTAX INTEGER { noConnect (2), cl (3), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique slot position In the Mux (Agent) where the dlci is routed to. cl - will represent any of the CL slots. This value can be selected for multiple DLCIs of the product. In the ?004 Unit the entries io6(10)..io16) are not valid" ::= { prtExPhPlDlciEntry 6} prtExPhPlDlciIConPrt OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) , exPrt7 (7) , exPrt8 (8) , exPrt9 (9) , exPrt10 (10) , clNMS (99), noConnect (100), inPrt1 (101) , inPrt2 (102) , inPrt3 (103) , inPrt4 (104) , inPrt5 (105) , inPrt6 (106) , inPrt7 (107) , inPrt8 (108) , inPrt9 (109) , inPrt10 (110) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique port id which the dlci is routed to. clNMS - will be used for NMS SNMP messages. It can be any port of the CL card. This value will be selectable only if prtExPhPlDlciIConSlt='cl' or 'notApplicable'." ::= { prtExPhPlDlciEntry 7} prtExPhPlDlciIConDlci OBJECT-TYPE SYNTAX Integer32 (1..991) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique internal connection dlci number, the dlci is routed to." ::= { prtExPhPlDlciEntry 8} prtExPhPlDlciTxBc OBJECT-TYPE SYNTAX INTEGER { full (1), zero (2), txBc9600bps (3), txBc14400bps (4), txBc19200bps (5), txBc28800bps (6), txBc32000bps (7), txBc38400bps (8), txBc48000bps (9), txBc56000bps (10), txBc57600bps (11), txBc64Kbps (12), txBc128Kbps (13), txBc192Kbps (14), txBc256Kbps (15), txBc320Kbps (16), txBc384Kbps (17), txBc448Kbps (18), txBc512Kbps (19), txBc768Kbps (20), txBc1024Kbps (21), -- --KM30 ; KM300 additional rates -- txBc16000bps (25), txBc112Kbps (26) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique Tx committed bandwidth on the user transmit line (or at the port receive line)." ::= { prtExPhPlDlciEntry 9} prtExPhPlDlciTxBe OBJECT-TYPE SYNTAX INTEGER { full (1), zero (2), txBe9600bps (3), txBe14400bps (4), txBe19200bps (5), txBe28800bps (6), txBe32000bps (7), txBe38400bps (8), txBe48000bps (9), txBe56000bps (10), txBe57600bps (11), txBe64Kbps (12), txBe128Kbps (13), txBe192Kbps (14), txBe256Kbps (15), txBe320Kbps (16), txBe384Kbps (17), txBe448Kbps (18), txBe512Kbps (19), txBe768Kbps (20), txBe1024Kbps (21), -- --KM30 ; KM300 additional rates -- txBc16000bps (25), txBc112Kbps (26) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique Tx excess bandwidth on the user transmit line (or at the port receive line)." ::= { prtExPhPlDlciEntry 10} prtExPhPlDlciRxBc OBJECT-TYPE SYNTAX INTEGER { full (1), zero (2), rxBc9600bps (3), rxBc14400bps (4), rxBc19200bps (5), rxBc28800bps (6), rxBc32000bps (7), rxBc38400bps (8), rxBc48000bps (9), rxBc56000bps (10), rxBc57600bps (11), rxBc64Kbps (12), rxBc128Kbps (13), rxBc192Kbps (14), rxBc256Kbps (15), rxBc320Kbps (16), rxBc384Kbps (17), rxBc448Kbps (18), rxBc512Kbps (19), rxBc768Kbps (20), rxBc1024Kbps (21), -- --KM30 ; KM300 additional rates -- rxBc16000bps (25), rxBc112Kbps (26) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique Rx committed bandwidth on the user receive line (or at the port transmit line)." ::= { prtExPhPlDlciEntry 11} prtExPhPlDlciRxBe OBJECT-TYPE SYNTAX INTEGER { full (1), zero (2), rxBe9600bps (3), rxBe14400bps (4), rxBe19200bps (5), rxBe28800bps (6), rxBe32000bps (7), rxBe38400bps (8), rxBe48000bps (9), rxBe56000bps (10), rxBe57600bps (11), rxBe64Kbps (12), rxBe128Kbps (13), rxBe192Kbps (14), rxBe256Kbps (15), rxBe320Kbps (16), rxBe384Kbps (17), rxBe448Kbps (18), rxBe512Kbps (19), rxBe768Kbps (20), rxBe1024Kbps (21), -- --KM30 ; KM300 additional rates -- rxBc16000bps (25), rxBc112Kbps (26) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique Rx excess bandwidth on the user receive line (or at the port transmit line)." ::= { prtExPhPlDlciEntry 12} prtExPhPlDlciPriority OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique priority of the pcv. 1 is the lowest priority and 8 is the highest priority." ::= { prtExPhPlDlciEntry 13} prtExPhPlDlciStatus OBJECT-TYPE SYNTAX INTEGER { disconnected (1), connected (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the status of the pvc. The status is disconnected(1) when one of the sides is programmed as not connected" ::= { prtExPhPlDlciEntry 14} -- Parameters of an external Modem which is connected to a High/Low Speed -- Port. prtExPhPlModemTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtExPhPlModemEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "External Modem Parameters. The write operation into the Table Objects is valid only for the TmpCnfg entry." ::= {prtPhPlCnfg 3} prtExPhPlModemEntry OBJECT-TYPE SYNTAX PrtExPhPlModemEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtExPhPlModemCnfgIdx,prtExPhPlModemSltIdx,prtExPhPlModemPrtIdx} ::= { prtExPhPlModemTable 1} PrtExPhPlModemEntry ::= SEQUENCE { prtExPhPlModemCnfgIdx Integer32, prtExPhPlModemSltIdx INTEGER, prtExPhPlModemPrtIdx INTEGER, prtExPhPlModemStatus INTEGER, prtExPhPlModemActivate INTEGER, prtExPhPlModemMaxIdleTime Integer32, prtExPhPlModemTimeBtwnCalls Integer32, prtExPhPlModemCallDelay Integer32 } prtExPhPlModemCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. " ::= { prtExPhPlModemEntry 1} prtExPhPlModemSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid" ::= { prtExPhPlModemEntry 2} prtExPhPlModemPrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number. In case of PH.1 card, only exPrt(1) is valid." ::= { prtExPhPlModemEntry 3} prtExPhPlModemStatus OBJECT-TYPE SYNTAX INTEGER { disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether a Dial Up Modem is enabled on this port. Default: disable" ::= { prtExPhPlModemEntry 4} prtExPhPlModemActivate OBJECT-TYPE SYNTAX INTEGER { onFirstFrame(2), always (3), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether the Dial Up Modem is activated when the first frame is received or it is always activated. Default: onFirstFrame" ::= { prtExPhPlModemEntry 5} prtExPhPlModemMaxIdleTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Max Time allowed in Seconds without any traffic before the line is disconnected. Legal Values are: 1 sec, 2 sec .. 5 sec, 10 sec, 20 sec.. 1 min, 2 min .. 10 min, 15 min, 20 min, 25 min, 30 min. 65535 sec. means that this parameter is not applicable. Default: 1 sec." ::= { prtExPhPlModemEntry 6} prtExPhPlModemTimeBtwnCalls OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Minimum Time in Seconds which is required after a call was disconnected. In this time no other call will be initiated from this Modem port even if there were frames transmitted to this port. This time is required for some Modems which have initializations that take a few seconds. Legal Values are: 0 sec. - 30 sec., 1-5 min. 65535 sec. means that this parameter is not applicable. Default: 0 sec" ::= { prtExPhPlModemEntry 7} prtExPhPlModemCallDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Time in Seconds that the device will wait before dialing to the remote device. This feature is mostly used when there is a backup modem to the main link and the main link is down. In this case it is important to prevent the 2 devices from dialing through the backup modems to each other at the same time. It is advised to configure one side with a small call delay and the other side with a large call delay. Legal Values are: 0 - 30, 60, 120, 180, 240, 300, 600, 900, 1200, 1500, 1800 . 65535 sec. means that this parameter is not applicable. Default: 0 sec" ::= { prtExPhPlModemEntry 8} -- -- Megaplex ?000/?004 LS-2 TDM I/O family card include: -- Ls2-CCITT-X.50, Ls2-CCITT-X.58, Ls2-AT&T-SDM -- --prtExLs2CnfgTable OBJECT IDENTIFIER ::= {prtLs2Cnfg 1} --prtInLs2CnfgTable OBJECT IDENTIFIER ::= {prtLs2Cnfg 2} prtExLs2CnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtExLs2CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= {prtLs2Cnfg 1} prtExLs2CnfgEntry OBJECT-TYPE SYNTAX PrtExLs2CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtExLs2CnfgIdx, prtExLs2SltIdx, prtExLs2PrtIdx } ::= {prtExLs2CnfgTable 1} PrtExLs2CnfgEntry ::= SEQUENCE { prtExLs2CnfgIdx Integer32, prtExLs2SltIdx INTEGER, prtExLs2PrtIdx INTEGER, prtExLs2Connect INTEGER, prtExLs2Rate INTEGER, prtExLs2ClkMode INTEGER, prtExLs2Cts INTEGER, prtExLs2Dcd INTEGER, prtExLs2EnvIdx Integer32 } prtExLs2CnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg" ::= {prtExLs2CnfgEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. prtExLs2SltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid." ::= {prtExLs2CnfgEntry 2} prtExLs2PrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) , exPrt7 (7) , exPrt8 (8) , exPrt9 (9) , exPrt10 (10) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port index. For the Ls2/X.58 exPrt(7)..exPrt(10) are not valid." ::= {prtExLs2CnfgEntry 3} prtExLs2Connect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port should be considered in any of the mux algorithms." ::= {prtExLs2CnfgEntry 4} prtExLs2Rate OBJECT-TYPE SYNTAX INTEGER { r2400bps (2), r4800bps (3), r9600bps (4), r19200bps (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Port rates." ::= {prtExLs2CnfgEntry 5} prtExLs2ClkMode OBJECT-TYPE SYNTAX INTEGER { dce (1), ext-dce (2), dte (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique port operation clock mode." ::= {prtExLs2CnfgEntry 6} prtExLs2Cts OBJECT-TYPE SYNTAX INTEGER { on (2), rts-min (3), rts-max (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "CTS." ::= {prtExLs2CnfgEntry 7} prtExLs2Dcd OBJECT-TYPE SYNTAX INTEGER { on (2), card-sync (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "DCD." ::= {prtExLs2CnfgEntry 8} prtExLs2EnvIdx OBJECT-TYPE SYNTAX Integer32 (0..24) MAX-ACCESS read-write STATUS current DESCRIPTION "Envelope Index. When prtInLs2EnvAssign=auto, the value is 0 (not applicable)." ::= {prtExLs2CnfgEntry 9} -- Ls2 Internal composit channel parameters -- prtInLs2CnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtInLs2CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= {prtLs2Cnfg 2} prtInLs2CnfgEntry OBJECT-TYPE SYNTAX PrtInLs2CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtInLs2CnfgIdx, prtInLs2SltIdx, prtInLs2PrtIdx } ::= {prtInLs2CnfgTable 1} PrtInLs2CnfgEntry ::= SEQUENCE { prtInLs2CnfgIdx Integer32, prtInLs2SltIdx INTEGER, prtInLs2PrtIdx INTEGER, prtInLs2Connect INTEGER, prtInLs2Group Integer32, prtInLs2Member Integer32, prtInLs2LinkTo INTEGER, prtInLs2EnvAssign INTEGER } prtInLs2CnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg" ::= {prtInLs2CnfgEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. prtInLs2SltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid." ::= {prtInLs2CnfgEntry 2} prtInLs2PrtIdx OBJECT-TYPE SYNTAX INTEGER { inPrt1 (101), inPrt2 (102) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique internal port index." ::= {prtInLs2CnfgEntry 3} prtInLs2Connect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port should be considered in any of the mux algorithms. It also affects all the module considerations because the module has only one Internal interface which is the composite channel." ::= {prtInLs2CnfgEntry 4} prtInLs2Group OBJECT-TYPE SYNTAX Integer32 (1..12) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the group number of the port. LS-2 internal ports with the same group number share the same Time slot of the main link" ::= {prtInLs2CnfgEntry 5} prtInLs2Member OBJECT-TYPE SYNTAX Integer32 (1..4) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the group member id of the port. This parameter is for the automatic envelope assignment algorithm." ::= {prtInLs2CnfgEntry 6} prtInLs2LinkTo OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "It indicates the slot of the main link card to which the LS2 card is mapped. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort." ::= {prtInLs2CnfgEntry 7} prtInLs2EnvAssign OBJECT-TYPE SYNTAX INTEGER { auto (2), manual (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Envelope assignment type." ::= {prtInLs2CnfgEntry 8} -- -- Megaplex?000/?004 VC-2, VC-6, VC-2/R2, VC-Q TDM I/O family port. -- (Vc2E&m,Vc2Fxs1Plar,Vc2Fxo1,Vc2Fxs2,Vc2Fxo2,Vc2Fxs3,Vc2Fxo3) -- Vc6E&M, Vc6Fxo, Vc6Fxs, Vc6aE&M, Vc6aFxo, Vc6aFxs -- Vc2/R2(Fxs) -- VC-Q -- VC-12, VC-12/6 -- VC-8, VC-16 prtVc2CnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtVc2CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= { cnfgPrtMux 5} prtVc2CnfgEntry OBJECT-TYPE SYNTAX PrtVc2CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtVc2CnfgIdx, prtVc2SltIdx, prtVc2PrtIdx } ::= { prtVc2CnfgTable 1} PrtVc2CnfgEntry ::= SEQUENCE { prtVc2CnfgIdx Integer32, prtVc2SltIdx INTEGER, prtVc2PrtIdx Integer32, prtExVc2Connect INTEGER, prtExVc2TransGain Integer32, prtExVc2ReceiveGain Integer32, prtExVc2Wire INTEGER, prtExVc2CodingLaw INTEGER, prtExVc2Sig INTEGER, prtExVc2Oos INTEGER, prtExVc2LinkTo INTEGER, prtExVc2OperMode INTEGER, prtExVc2SigProfile INTEGER, prtExVc2CallEnable INTEGER, prtExVc2R2Delay INTEGER, prtExVc2CasStd INTEGER, prtExVc2EchoCanceler INTEGER, prtExVc2IfType INTEGER, prtExVc2Encoding INTEGER, prtExVc2TxBitCode OCTET STRING, prtExVc2RxBitOutput OCTET STRING, prtExVc2MeterRate INTEGER, prtExVc2IfSignaling INTEGER, prtExVc2SeizeAck INTEGER, prtExVc2EandMType INTEGER, prtExVc2RemType INTEGER, prtExVc2ConvTime INTEGER, prtExVc2SigFeedback INTEGER, prtExVc2EchoCancelerModule INTEGER } prtVc2CnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg" ::= {prtVc2CnfgEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. prtVc2SltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. For Stand Alone products like WR: notApplicable (255)" ::= {prtVc2CnfgEntry 2} prtVc2PrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier of the port, within the card. For Megaplex card ports, Web Ranger and FCD-IP Voice ports the values will be: exPrt1 (1) exPrt2 (2) exPrt3 (3) exPrt4 (4) exPrt5 (5) exPrt6 (6) exPrt7 (7) exPrt8 (8) exPrt9 (9) exPrt10 (10) exPrt11 (11) exPrt12 (12) exPrt13 (13) exPrt14 (14) exPrt15 (15) exPrt16 (16) For LA-240: The index for fixed voice ports will be - exPrt6 (6) exPrt7 (7) exPrt8 (8) exPrt9 (9) The index for voice card ports will be - Slot number * 100 + ch (for IO-1: 101..104, for IO-2: 201..204)." ::= {prtVc2CnfgEntry 3} prtExVc2Connect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3), v51 (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port should be considered in any of the mux algorithms." ::= {prtVc2CnfgEntry 4} prtExVc2TransGain OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Transmit gain in dBm. For ports of VC-6A, VC-6AG, VC-8 and VC-16 cards, the units will be 0.1dBm because valid values can be in 0.5dBm steps." ::= {prtVc2CnfgEntry 5} prtExVc2ReceiveGain OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Receive gain in dBm. For ports of VC-6A, VC-6AG, VC-8 and VC-16 cards, the units will be 0.1dBm because valid values can be in 0.5dBm steps." ::= {prtVc2CnfgEntry 6} prtExVc2Wire OBJECT-TYPE SYNTAX INTEGER { w2wire (1), w4wire (2), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "For some cards, this object is equal for all the ports in the specific card because of HW limitations. For FXO & FXS this parameter is not applicable." ::= {prtVc2CnfgEntry 7} prtExVc2CodingLaw OBJECT-TYPE SYNTAX INTEGER { aLAW (1), uLAW (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the Method/Law for decoding/encoding the voice information. aLaw(1) is the standard Law for E1 links. uLaw(2) is the standard Law for T1 links. This object is equal for all the ports in the specific module because of HW limitations" ::= {prtVc2CnfgEntry 8} prtExVc2Sig OBJECT-TYPE SYNTAX INTEGER { noSignaling (1), robbedBitMultiFrame (2), chAssociatedE1 (3), robbedBitFrame (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the method for decoding/encoding the signaling information(on/off hook). noSignaling (1) - not using signaling (only voice). robbedBitMultiFrame(2) - is the standard method for T1 links and proprietary method for E1 links. chAssociatedE1 (3) - is valid only for E1 G.732S links. robbedBitFrame (4) - is proprietary method implimenting 7 bit for the voice and 1 bit dedicated for signaling. For some cards, this object is equal for all the ports in the specific module because of HW limitations." ::= {prtVc2CnfgEntry 9} prtExVc2Oos OBJECT-TYPE SYNTAX INTEGER { forcedIdle (1), forcedBusy (2), busyIdle (3), idleBusy (4), notApplicable (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is equal for all the ports in the specific card because of HW limitations" ::= {prtVc2CnfgEntry 10} prtExVc2LinkTo OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This attribute indicates the slot of the ML card to which the VC card is mapped. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort." ::= {prtVc2CnfgEntry 11} prtExVc2OperMode OBJECT-TYPE SYNTAX INTEGER { normal (2), unidirectRx (3), broadcast (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the operation mode of the port. normal = bi-directional (Tx/Rx) unidirectRx = unidirectional Rx. broadcast = Tx upon request." ::= {prtVc2CnfgEntry 12} prtExVc2SigProfile OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), manual (2), p1 (3), p2 (4), p3Fxo3S3 (5), reversePolarity (6), --3RP meteringPulse (7), --3MP p4 (8) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the Signaling Profile of the port. notApplicable - for VC-2 family and when prtExVc2Sig=noSignaling(1) p1 = profile 1 p2 = profile 2 p3 = profile 3 p4 = profile 4 " ::= {prtVc2CnfgEntry 13} prtExVc2CallEnable OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), incoming (2), outgoing (3), both (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the Enabled Call direction. notApplicable - for all cards except VC-2/R2. both - incoming + outgoing." ::= {prtVc2CnfgEntry 14} prtExVc2R2Delay OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), terrestrial (2), satellite (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the R2 Delay. notApplicable - for all cards except VC-2/R2." ::= {prtVc2CnfgEntry 15} prtExVc2CasStd OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), r2Q422 (2), specialA (3), specialB (4), specialC (5), specialD (6), specialE (7), specialF (8), specialG (9) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the CAS (Channel Associated Signaling) Standard. notApplicable - for all cards except VC-2/R2." ::= {prtVc2CnfgEntry 16} prtExVc2EchoCanceler OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), off (2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Echo canceler activation. notApplicable - for VC-2 and VC-6 cards." ::= {prtVc2CnfgEntry 17} prtExVc2IfType OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), w2Em (2), w4Em (3), fxo (4), fxs (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Interface Type." ::= {prtVc2CnfgEntry 18} prtExVc2Encoding OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), pcm (2), adpcm (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Voice Encoding Mode." ::= {prtVc2CnfgEntry 19} prtExVc2TxBitCode OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION " - - - For MP & FCD - - - This object represents 4 parameters, by 2 Octets : Tx D Bit Code-MSB nibble, Tx C Bit Code- nibble, Tx B Bit Code- nibble, Tx A Bit Code-LSB nibble. Each nibble: 0 hex = 0000 = Not Applicable 1 hex = 0001 = M lead 2 hex = 0010 = M lead inverse 3 hex = 0011 = Reverse Polarity 4 hex = 0100 = Metering Pulse 5 hex = 0101 = Forced 1 6 hex = 0110 = Forced 0 7-F hex - not used (invalid values) This object will be RO if prtExVc2SigProfile is NOT manual. - - - For WR II - - - This object represents the following 4 parameters by 2 Octets: 1. On/Off hook signaling transmission mode from the FXS towards the T1/E1 (MSB nibble 1). 2. Default signaling bits that are not in use (nibble 2). 3. Ring Detection signaling transmission mode from the FXO towards the T1/E1(nibble 3). 4. M (Mouth) Signaling transmission mode from the E&M towards the T1/E1(LSB nibble 4). Each nibble: --------------------------------------------------------------------------------------- Value On/Off Hook Default sig. Ring Detect. M (Mouth) --------------------------------------------------------------------------------------- 0 hex = 0000 Not Applicable Not Applicable. Not Applicable Not Applicable 1 hex = 0001 Tx A bit Values 1-3 are Tx A bit Tx A bit 2 hex = 0010 Tx A bit inverse for On/Off Hook Tx A bit inv. Tx A bit inv. 3 hex = 0011 Tx B bit A,B,A Inv,B Inv. Tx B bit Tx B bit 4 hex = 0100 Tx B bit inverse Values 4-7 are Tx B bit inv. Tx B bit inv. 5 hex = 0101 not Used-invalid for On/Off Hook not Used-invalid not Used-invalid 6 hex = 0110 not Used-invalid A, A Inverse. not Used-invalid not Used-invalid 7 hex = 0111 not Used-invalid not Used-invalid not Used-invalid 8 hex = 1000 not Used-invalid Values 8-11 are not Used-invalid not Used-invalid 9 hex = 1001 not Used-invalid for On/Off Hook not Used-invalid not Used-invalid A hex = 1010 not used-invalid B, B Inverse. not Used-invalid not Used-invalid B hex = 1011 not used-invalid The Bits order: not Used-invalid not Used-invalid C-F hex not used-invalid ABCD not Used-invalid not Used-invalid Default value: 11 11 " ::= {prtVc2CnfgEntry 20} prtExVc2RxBitOutput OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION " - - - For MP (VC-Q card only) & FCD - - - This object represents 3 parameters by 2 Octets: Spare -MSB nibble, always=0 hex E Lead Output - nibble, Reverse Polarity Output- nibble, Metering Pulse Output -LSB nibble. Each nibble: 0 hex = 0000 = Not Applicable 1 hex = 0001 = Rx A bit 2 hex = 0010 = Rx A bit inverse 3 hex = 0011 = Rx B bit 4 hex = 0100 = Rx B bit inverse 5 hex = 0101 = Rx C bit 6 hex = 0110 = Rx C bit inverse 7 hex = 0111 = Rx D bit 8 hex = 1000 = Rx D bit inverse 9 hex = 1001 = none A-F hex - not used (invalid values) This object will be RO if prtExVc2SigProfile is NOT manual. - - - For MP (VC-8, VC-16, VC-16A cards) - - - This object represents 4 parameters, by 2 Octets : Tx D Bit Code-MSB nibble, Tx C Bit Code- nibble, Tx B Bit Code- nibble, Tx A Bit Code-LSB nibble. Each nibble: 0 hex = 0000 = Not Applicable 1 hex = 0001 = not used (invalid value) 2 hex = 0010 = not used (invalid value) 3 hex = 0011 = not used (invalid value) 4 hex = 0100 = not used (invalid value) 5 hex = 0101 = Forced 1 6 hex = 0110 = Forced 0 7-F hex - not used (invalid values) This object will be RO. - - - For WR II - - - This object represents the following 2 parameters in 1 Octet: 1. On/Off hook signaling receive mode from the T1/E1 into the FXS/FXO (MSB nibble 1). 2. E (Ear) Signaling receive mode from the T1/E1 into the E&M (LSB nibble 2). Each nibble: --------------------------------------------------------------------------------------- Value On/Off Hook E (Ear) --------------------------------------------------------------------------------------- 0 hex = 0000 Not Applicable Not Applicable 1 hex = 0001 Rx A bit Rx A bit 2 hex = 0010 Rx A bit inverse Rx A bit inverse 3 hex = 0011 Rx B bit Rx B bit 4 hex = 0100 Rx B bit inverse Rx B bit inverse 5-F hex not used-invalid not Used-invalid Default value: 11 " ::= {prtVc2CnfgEntry 21} prtExVc2MeterRate OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), r16Khz (2), r12Khz (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This entry is applicable only for VC-6A/FXO, VC-6A/FXS, VC-8/FXO, VC-8/FXS, VC-16/FXO and VC-16/FXS. Meter Rate means rate of Call Meter in Public Phones, in KHz units. For some cards, the value must be the same for all card's ports." ::= {prtVc2CnfgEntry 22} prtExVc2IfSignaling OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), loopStart (2), groundStart (3), winkStart (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This entry is applicable only for VC-6A, VC-6AG, VC-8/FXO, VC-8/FXS, VC-16/FXO and VC-16/FXS cards. Interface Analog Signaling. Must be the same for all card's ports. loopStart - for the usual trunk/phone types. groundStart - for trunks that need Ground signaling . winkStart - for trunks that need Reverse Polarity. " ::= {prtVc2CnfgEntry 23} prtExVc2SeizeAck OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter shows whether the device will acknowledge a seize signal (On/Off Hook). When the value is set to yes(3) & the device receives an on/off hook signal it will transmit back an on/off hook signal. When the value is set to no(2) & the device receives an on/off hook signal it will NOT transmit back an on/off hook signal. Default value for WR FXO: no(2)." ::= {prtVc2CnfgEntry 24} prtExVc2EandMType OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), type1 (2), type2 (3), type3 (4), type5 (5) -- SSDC5 } MAX-ACCESS read-write STATUS current DESCRIPTION "This is the signaling type on the E&M analog side. The analog signaling includes voltage, no. of pins and other parameters." ::= {prtVc2CnfgEntry 25} prtExVc2RemType OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), lb (2), pbx (3), e1 (4), t1 (5), --T1ESF t1D4 (6) } MAX-ACCESS read-write STATUS current DESCRIPTION "Remote Type. Applicable for VC-6A/4LB card & for IPMUX-1E Far End Type - E1,T1(T1-ESF) or T1-D4 ." ::= {prtVc2CnfgEntry 26} prtExVc2ConvTime OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), m2 (2), m3 (3), m5 (4), unlimited (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Conversation Time in minutes. Applicable for VC-6A/4LB card." ::= {prtVc2CnfgEntry 27} prtExVc2SigFeedback OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Signaling Feedback. Applicable for VC-8/FXO and VC-16/FXO cards." ::= {prtVc2CnfgEntry 28} prtExVc2EchoCancelerModule OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), notExist (2), exist (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates whether Echo canceler module exists for this port." ::= {prtVc2CnfgEntry 29} -- -- Megaplex?000/?004 port specific config for HS(TDM) modules -- HS-2,HS-3,HS-Q, HS-Q/SC, HS-6, HS-12 -- prtHsfCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtHsfCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= { cnfgPrtMux 6} prtHsfCnfgEntry OBJECT-TYPE SYNTAX PrtHsfCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtHsfCnfgIdx, prtHsfSltIdx, prtHsfPrtIdx } ::= { prtHsfCnfgTable 1} PrtHsfCnfgEntry ::= SEQUENCE { prtHsfCnfgIdx Integer32, prtHsfSltIdx INTEGER, prtHsfPrtIdx INTEGER, prtExHsfConnect INTEGER, prtExHsfRate INTEGER, prtExHsfClkMode INTEGER, prtExHsfCts INTEGER, prtExHsfFifoSize INTEGER, prtExHsfLinkTo INTEGER, prtExHsfOperMode INTEGER, prtExHsfInbandLoopback INTEGER, prtExHsfClkPolarity INTEGER, prtExHsfControlSignal INTEGER } prtHsfCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relate to the TmpCnfg. " ::= {prtHsfCnfgEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. prtHsfSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid." ::= {prtHsfCnfgEntry 2} prtHsfPrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) , exPrt7 (7) , exPrt8 (8) , exPrt9 (9) , exPrt10 (10) , exPrt11 (11) , exPrt12 (12) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique external port index. Hs2 has only two ports (exPrt1,exPrt2). Hs3 has three ports (exPrt1,exPrt2,exPrt3). Hsq and hsqN has four ports. Hs6 has six external ports. Hs12 has twelve external ports." ::= {prtHsfCnfgEntry 3} prtExHsfConnect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port should be considered in any of the mux algorithms." ::= {prtHsfCnfgEntry 4} prtExHsfRate OBJECT-TYPE SYNTAX INTEGER { r1x56eq56Kbps (1), r1x64eq64Kbps (2), r2x56eq112Kbps (3), r2x64eq128Kbps (4), r3x56eq168Kbps (5), r3x64eq192Kbps (6), r4x56eq224Kbps (7), r4x64eq256Kbps (8), r5x56eq280Kbps (9), r5x64eq320Kbps (10), r6x56eq336Kbps (11), r6x64eq384Kbps (12), r7x56eq392Kbps (13), r7x64eq448Kbps (14), r8x56eq448Kbps (15), r8x64eq512Kbps (16), r9x56eq504Kbps (17), r9x64eq576Kbps (18), r10x56eq560Kbps (19), r10x64eq640Kbps (20), r11x56eq616Kbps (21), r11x64eq704Kbps (22), r12x56eq672Kbps (23), r12x64eq768Kbps (24), r13x56eq728Kbps (25), r13x64eq832Kbps (26), r14x56eq784Kbps (27), r14x64eq896Kbps (28), r15x56eq840Kbps (29), r15x64eq960Kbps (30), r16x56eq896Kbps (31), r16x64eq1024Kbps(32), r17x56eq952Kbps (33), r17x64eq1088Kbps(34), r18x56eq1008Kbps(35), r18x64eq1152Kbps(36), r19x56eq1064Kbps(37), r19x64eq1216Kbps(38), r20x56eq1120Kbps(39), r20x64eq1280Kbps(40), r21x56eq1176Kbps(41), r21x64eq1344Kbps(42), r22x56eq1232Kbps(43), r22x64eq1408Kbps(44), r23x56eq1288Kbps(45), r23x64eq1472Kbps(46), r24x56eq1344Kbps(47), r24x64eq1536Kbps(48), r25x56eq1400Kbps(49), r25x64eq1600Kbps(50), r26x56eq1456Kbps(51), r26x64eq1664Kbps(52), r27x56eq1512Kbps(53), r27x64eq1728Kbps(54), r28x56eq1568Kbps(55), r28x64eq1792Kbps(56), r29x56eq1624Kbps(57), r29x64eq1856Kbps(58), r30x56eq1680Kbps(59), r30x64eq1920Kbps(60), r31x56eq1736Kbps(61), r31x64eq1984Kbps(62), r32Kbps (63) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the port speed. " ::= {prtHsfCnfgEntry 5} prtExHsfClkMode OBJECT-TYPE SYNTAX INTEGER { dce (1), ext-dce (2), dte (3), none (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique port operation clock mode." ::= { prtHsfCnfgEntry 6} prtExHsfCts OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), on (2), rts (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique CTS control line operation mode." ::= {prtHsfCnfgEntry 7} prtExHsfFifoSize OBJECT-TYPE SYNTAX INTEGER { auto (2), s16bits (3), s30bits (4), s52bits (5), s72bits (6) } MAX-ACCESS read-write STATUS current DESCRIPTION "Size in bits." ::= {prtHsfCnfgEntry 8} prtExHsfLinkTo OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This attribute indicates a slot of Main Link module, that the port is linked to. This object is the same for all the ports in the specific card because of HW limitations. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort." ::= {prtHsfCnfgEntry 9} prtExHsfOperMode OBJECT-TYPE SYNTAX INTEGER { normal (2), unidirectRx (3), broadcast (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the operation mode of the port. normal = bi-directional (Tx/Rx) unidirectRx = unidirectional Rx. broadcast = Tx upon request." ::= {prtHsfCnfgEntry 10} prtExHsfInbandLoopback OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disabled (2), ft1Enabled (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates if Inband Loopback from the Network should be enabled or disabled." ::= {prtHsfCnfgEntry 11} prtExHsfClkPolarity OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), normal (2), invert (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the clock polarity. For FCD-M this object will be applicable only for the fixed HS port (the fixed port on the device)." ::= {prtHsfCnfgEntry 12} prtExHsfControlSignal OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), local (2), endToEnd (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the Control Signal according to G.797 ITU-T standard. For FCD-M this object will be applicable for the fixed HS port (the fixed port on the device) and HS-Q/N channels. Local and End to End are applicable only when channel Interface type is RS-530, else it will be Not Applicable." ::= {prtHsfCnfgEntry 13} -- -- Megaplex?000/?004 Hs-4/1(HS4T1) HS-4/2(HS4E1) port configuration -- --prtExHs4CnfgTable OBJECT IDENTIFIER ::= {prtHs4Cnfg 1} --prtExHs4TsCnfgTable OBJECT IDENTIFIER ::= {prtHs4Cnfg 2} prtExHs4CnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtExHs4CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= {prtHs4Cnfg 1} prtExHs4CnfgEntry OBJECT-TYPE SYNTAX PrtExHs4CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtExHs4CnfgIdx, prtExHs4SltIdx, prtExHs4PrtIdx } ::= { prtExHs4CnfgTable 1} PrtExHs4CnfgEntry ::= SEQUENCE { prtExHs4CnfgIdx Integer32, prtExHs4SltIdx INTEGER, prtExHs4PrtIdx INTEGER, prtExHs4Connect INTEGER, prtExHs4LineType INTEGER, prtExHs4LineCode INTEGER, prtExHs4LineLen INTEGER, prtExHs4RestoreT INTEGER, prtExHs4OosSig INTEGER, prtExHs4OosCode INTEGER, prtExHs4IdleCode Integer32, prtExHs4MfClkSrcSlt INTEGER, prtExHs4MfClkSrcPrt INTEGER } prtExHs4CnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg" ::= {prtExHs4CnfgEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. prtExHs4SltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted." ::= {prtExHs4CnfgEntry 2} prtExHs4PrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) } MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier of the port, within the card." ::= {prtExHs4CnfgEntry 3} prtExHs4Connect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port should be considered in any of the mux algorithm. It also affects all the module considerations because the card has only one external (physical) interface." ::= {prtExHs4CnfgEntry 4} prtExHs4LineType OBJECT-TYPE SYNTAX INTEGER { esfT1 (2), --> dsx1ESF sfT1 (3), --> dsx1D4 g732nE1 (4), --> dsx1E1 g732nE1CRC (5), --> dsx1E1-CRC g732sE1 (6), --> dsx1E1-MF g732sE1CRC (7) --> dsx1E1-MF-CRC } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute is the line type parameter for T1/E1 interface. The user should select only the parameters relevant to the specific card: T1 line code parameters for the HS-4/1 and E1 line code parameters for the HS-4/2. This parameter has the same values as dsx1LineType in T1/E1 MIB (RFC-1406). The parameters in dsx1LineType are: other (1) dsx1ESF (2) dsx1D4 (3) dsx1E1 (4) dsx1E1-CRC (5) dsx1E1-MF (6) dsx1E1-MF-CRC (7)" ::= {prtExHs4CnfgEntry 5} prtExHs4LineCode OBJECT-TYPE SYNTAX INTEGER { b7T1 (1), --> dsx1JBZS b8zsT1 (2), --> dsx1B8ZS hdb3E1 (4) --> dsx1HDB3 } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute is the line code parameter used for T1/E1 interface. The user should select only the parameters relevant to the specific card: T1 line code parameters for the MPH.1/T1 and E1 line code parameters for the MPH.1/E1. This parameter has the same values as dsx1LineCoding in T1/E1 MIB (RFC-1406). The parameters in dsx1LineCoding are: dsx1JBZS (1) dsx1B8ZS (2) dsx1HDB3 (3) dsx1ZBTSI (4) dsx1AMI (5) other (6)" ::= {prtExHs4CnfgEntry 6} prtExHs4LineLen OBJECT-TYPE SYNTAX INTEGER { unknown (1), len0p133ft (2), len134p266ft (3), len267p399ft (4), len400p533ft (5), len534p655ft (6), fcc68 (7) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute is the line length parameter used only for T1 interfaces. len399p533ft=len-399-533ft " ::= {prtExHs4CnfgEntry 7} prtExHs4RestoreT OBJECT-TYPE SYNTAX INTEGER { restoreT1secFast (2), restoreT10sec62411 (3), ccittE1 (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Time passing from the disappearance of the loss of synchronization condition (red alarm), to the restoration of normal service." ::= {prtExHs4CnfgEntry 8} prtExHs4OosSig OBJECT-TYPE SYNTAX INTEGER { notsupported (2), forcedIdle (3), forcedBusy (4), busyIdle (5), idleBusy (6) } MAX-ACCESS read-write STATUS current DESCRIPTION "Out of Service signal type." ::= {prtExHs4CnfgEntry 9} prtExHs4OosCode OBJECT-TYPE SYNTAX INTEGER { notsupported (2), oosCode00H (3), oosCode1aH (4), oosCode54H (5), oosCode7eH (6), oosCode7fH (7), oosCode98H (8), oosCode9eH (9), oosCoded5H (10), oosCodee4H (11), oosCodeffH (12) } MAX-ACCESS read-write STATUS current DESCRIPTION "OOS Code" ::= {prtExHs4CnfgEntry 10} prtExHs4IdleCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Type value(00 - FF HEX), excluding 0H,8H,10H,12H,21H,24H, 42H,49H,84H,92H" ::= {prtExHs4CnfgEntry 11} prtExHs4MfClkSrcSlt OBJECT-TYPE SYNTAX INTEGER { local (2), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port Tx is multiframe synchronized with Rx multiframe of another port and the slot position of that port. This opration is required in order to bypass signaling of PCM voice channels. When its value is Local(2) there is no meaning to 'prtExHs4MfClkSrcPrt' parameter. In the ?004 Unit the entries io6(10)..io16) are not valid" ::= {prtExHs4CnfgEntry 12} prtExHs4MfClkSrcPrt OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1), exPrt2 (2), inPrt1 (101) } MAX-ACCESS read-write STATUS current DESCRIPTION "A unique number to identify a port position in the mux if the MultiFrame clock source is valid (YES). inPrt1 - for MTML-H/E1 cards." ::= {prtExHs4CnfgEntry 13} -- -- Hs4 Time Slot Config Table -- prtExHs4TsCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtExHs4TsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= {prtHs4Cnfg 2} prtExHs4TsEntry OBJECT-TYPE SYNTAX PrtExHs4TsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtExHs4TsCnfgIdx, prtExHs4TsSltIdx, prtExHs4TsPrtIdx, prtExHs4TsIdx } ::= { prtExHs4TsCnfgTable 1} PrtExHs4TsEntry ::= SEQUENCE { prtExHs4TsCnfgIdx Integer32, prtExHs4TsSltIdx INTEGER, prtExHs4TsPrtIdx INTEGER, prtExHs4TsIdx Integer32, prtExHs4TsIConSlot INTEGER, prtExHs4TsIConPrt INTEGER, prtExHs4TsIConTs Integer32 } prtExHs4TsCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. " ::= { prtExHs4TsEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. prtExHs4TsSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid" ::= { prtExHs4TsEntry 2} prtExHs4TsPrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number. Hs4/T1 and Hs4/T1 cards have only one external interface." ::= { prtExHs4TsEntry 3} prtExHs4TsIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique time slot position. The valid time slots are: 1..24 for T1 Card and 1..31 for E1 interface. In G732S-E1 lines, time slot 16 is not valid for data, it is dedicated to multiframe synchronization bits and voice signaling." ::= { prtExHs4TsEntry 4} prtExHs4TsIConSlot OBJECT-TYPE SYNTAX INTEGER { noConnect (2), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), split (100) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the specified time slot is connected/routed internally in the Agent and to which card it is connected. In the ?004 Unit the entries io6(10)..io16) are not valid. split - will be used when the Src TS is connected to more than one slot OR more than one port (each needing less than a whole TS)." ::= {prtExHs4TsEntry 5} prtExHs4TsIConPrt OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) , exPrt7 (7) , exPrt8 (8) , exPrt9 (9) , exPrt10 (10) , exPrt11 (11) , exPrt12 (12) , noConnect (100) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the internally (In Mux) connected/routed port." ::= {prtExHs4TsEntry 6} prtExHs4TsIConTs OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique time slot position. The valid time slots are: 1..24 for T1 Module and 1..31 for E1 interface. In G732S-E1 lines time slot 16 is not valid for data, it is dedicated for multiframe synchronization bits and voice signaling." ::= { prtExHs4TsEntry 7} -- -- Megaplex?000/?004 and DXC Hs-U port configuration -- --prtExHsiCnfgTable OBJECT IDENTIFIER ::= {prtHsiCnfg 1} prtExHsiCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtExHsiCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= {prtHsiCnfg 1} prtExHsiCnfgEntry OBJECT-TYPE SYNTAX PrtExHsiCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtExHsiCnfgIdx, prtExHsiSltIdx, prtExHsiPrtIdx } ::= { prtExHsiCnfgTable 1} PrtExHsiCnfgEntry ::= SEQUENCE { prtExHsiCnfgIdx Integer32, prtExHsiSltIdx INTEGER, prtExHsiPrtIdx Integer32, prtExHsiConnect INTEGER, prtExHsiRate INTEGER, prtExHsiLinkTo INTEGER, prtExHsiInterface INTEGER, prtExHsiActType INTEGER } prtExHsiCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg" ::= {prtExHsiCnfgEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. prtExHsiSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), io13 (17), io14 (18), io15 (19), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted." ::= {prtExHsiCnfgEntry 2} prtExHsiPrtIdx OBJECT-TYPE SYNTAX Integer32 -- { -- exPrt1 (1), -- exPrt2 (2), -- exPrt3 (3), -- exPrt4 (4), -- exPrt5 (5), -- exPrt6 (6), -- exPrt7 (7), -- exPrt8 (8), -- exPrt9 (9), -- exPrt10 (10), -- exPrt11 (11), -- exPrt12 (12) -- } MAX-ACCESS read-only STATUS current DESCRIPTION "A unique port identifier within the card. For MP : 1..12 For DXC: 111 .. 2531. See DXC R6 spec for port index convention. For FCD-A, 'S' Interface external ports: 131, 141, 151, 161." ::= {prtExHsiCnfgEntry 3} prtExHsiConnect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3), v51 (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port should be considered in any of the mux algorithms. v51 - this port is connected to a V5.1 interface. All rest of the values will be 'notApplicable' in this case. V5.1 MIB will be used instead." ::= {prtExHsiCnfgEntry 4} prtExHsiRate OBJECT-TYPE SYNTAX INTEGER { r600bps (2), r1200bps (3), r2400bps (4), r4800bps (5), r9600bps (6), r19200bps (7), r38400bps (8), r48kbps (9), r56kbps (10), r64kbps (11), r128kbps (12), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the port speed." ::= {prtExHsiCnfgEntry 5} prtExHsiLinkTo OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "It indicates the slot of the main link card to which the HS-? card is mapped. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort." ::= {prtExHsiCnfgEntry 6} prtExHsiInterface OBJECT-TYPE SYNTAX INTEGER { lt (1), nt (2), te (3), lt1 (4), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "It indicates the interface type: lt = line termination nt = network termination te = terminal equipment. lt1 - for ASMi-31 connection (not ISDN) For MP: For HS-U/I and HS-U/1 only 'lt' and 'nt' are applicable. For HS-S , only 'te' and 'nt' are applicable. For HS-U, this object is not applicable. For HS-U6, HS-U12, are applicable: 'lt'=lt-i,'nt'=nt-i, lt1. For DXC: For HS-U8, HS-U16, are applicable: 'lt'=LT-I,'nt'=NT-I, 'lt1'=LT-1." ::= {prtExHsiCnfgEntry 7} prtExHsiActType OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), type1 (2), type2 (3), type3 (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "It indicates the Activation Type. Activation Type is the Synchronization type towards the PBX. It is applicable only when prtExHsiInterface=nt. notApplicable - for cards that do not support this object, or when prtExHsiInterface is NOT nt." ::= {prtExHsiCnfgEntry 8} --prtInHsiCnfgTable OBJECT IDENTIFIER ::= {prtHsiCnfg 2} --This table is not applicable for MP-2100 HS-U card type prtInHsiCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtInHsiCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry. This table is not applicable for MP-2100 HS-U card type." ::= {prtHsiCnfg 2} prtInHsiCnfgEntry OBJECT-TYPE SYNTAX PrtInHsiCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtInHsiCnfgIdx, prtInHsiSltIdx, prtInHsiPrtIdx } ::= { prtInHsiCnfgTable 1} PrtInHsiCnfgEntry ::= SEQUENCE { prtInHsiCnfgIdx Integer32, prtInHsiSltIdx INTEGER, prtInHsiPrtIdx Integer32, prtInHsiConnect INTEGER, prtInHsiRate INTEGER, prtInHsiConcentratedTo Integer32 } prtInHsiCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg" ::= {prtInHsiCnfgEntry 1} prtInHsiSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), io13 (17), io14 (18), io15 (19), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a unique slot position where the card is inserted." ::= {prtInHsiCnfgEntry 2} prtInHsiPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique port identifier within the card. Valid values for MP: inPrt1 (101) .. inPrt48 (148). Valid values for DXC: 11012.. 25316. See DXC R6 spec for port index convention." ::= {prtInHsiCnfgEntry 3} prtInHsiConnect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port should be considered in any of the mux algorithms." ::= {prtInHsiCnfgEntry 4} prtInHsiRate OBJECT-TYPE SYNTAX INTEGER { r600bps (2), r1200bps (3), r2400bps (4), r4800bps (5), r9600bps (6), r19200bps (7), r38400bps (8), r48kbps (9), r56kbps (10), r64kbps (11), r128kbps (12), concentrated (13), notConnected (100), notApplicable(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the port speed. For HS-U/I and HS-S ports: 2 bit - up to 9600bps 4 bit - 19200bps 8 bit - 38400bps .. 64kbps. concentrated - this D channel goes to a Concentration channel, that represents many channels that this value was selected for them. The Concentrated channel is an Internal D Channel of the same card. This value is applicable only for D channels, except Concentration channel itself. --for HS-S and HS-U/I cards the Concentration channel will always be: internal-13 --for MP-2200 HS-S12, HS-S6, HS-U12, HS-U6 and DXC HS-U8 and HS-U16 cards, the Concentration channel is selected via the prtInHsiConcentratedTo object. notConnected - same as prtInHsiConnect=no." ::= {prtInHsiCnfgEntry 5} prtInHsiConcentratedTo OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The Concentration D Channel of the prtInHsiPrtIdx port. The port always belongs to the same card as prtInHsiPrtIdx port. This object is applicable only when prtInHsiRate=concentrated. Valid values: - notApplicable: 255 - for MP-2200: HS-S12, HS-U12 cards: inPrt37 (137) .. inPrt48 (148). HS-S6, HS-U6 cards: inPrt19 (119) .. inPrt24 (124). - for DXC: HS-U8 cards: 112 .. 254 HS-U16 cards: 112 .. 258. See DXC R6 spec for port index convention." ::= {prtInHsiCnfgEntry 6} -- -- Megaplex?000/?004 Hs-R and HS-U port configuration -- DXC HS-U8, HS-U16 port configuration for Interface=LT-1 -- --prtExHsrCnfgTable OBJECT IDENTIFIER ::= {prtHsrCnfg 1} prtExHsrCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtExHsrCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= {prtHsrCnfg 1} prtExHsrCnfgEntry OBJECT-TYPE SYNTAX PrtExHsrCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtExHsrCnfgIdx, prtExHsrSltIdx, prtExHsrPrtIdx } ::= { prtExHsrCnfgTable 1} PrtExHsrCnfgEntry ::= SEQUENCE { prtExHsrCnfgIdx Integer32, prtExHsrSltIdx INTEGER, prtExHsrPrtIdx Integer32, prtExHsrConnect INTEGER, prtExHsrProtocol INTEGER, prtExHsrRate INTEGER, prtExHsrDataBits INTEGER, prtExHsrParity INTEGER, prtExHsrStopBits INTEGER, prtExHsrCts INTEGER, prtExHsrClkMode INTEGER, prtExHsrLinkTo INTEGER, prtExHsrDcdDsr INTEGER, prtExHsrOperMode INTEGER, prtExHsrRtsDtr INTEGER, prtExHsrLlbEnable INTEGER, prtExHsrRlbEnable INTEGER, prtExHsrRateAdapt INTEGER, prtExHsrRemoteModem INTEGER } prtExHsrCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg" ::= {prtExHsrCnfgEntry 1} prtExHsrSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), io13 (17), io14 (18), io15 (19) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a unique slot position where the card is inserted." ::= {prtExHsrCnfgEntry 2} prtExHsrPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique prt identifier within the card. Valid values: For MP: - For HS-R cards: exPrt1 (1) .. exPrt4 (4) - For HS-U/1 cards: inPrt1 (101) .. inPrt4 (104) - For HS-S12, HS-S6, HS-U12, HS-U6 cards: exPrt1 (1) .. exPrt12 (12). This MIB table is used only for LT-1 interface. For DXC: - For HS-U8, HS-U16 cards: 111 .. 2531 (See DXC R6 spec for port index convention). This MIB table is used only for LT-1 interface." ::= {prtExHsrCnfgEntry 3} prtExHsrConnect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether the port should be considered in any of the mux algorithms." ::= {prtExHsrCnfgEntry 4} prtExHsrProtocol OBJECT-TYPE SYNTAX INTEGER { sync (2), async (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the protocol." ::= {prtExHsrCnfgEntry 5} prtExHsrRate OBJECT-TYPE SYNTAX INTEGER { r600bps (2), r1200bps (3), r2400bps (4), r4800bps (5), r9600bps (6), r19200bps (7), r38400bps (8), r48kbps (9), r56kbps (10), r64kbps (11), r16000bps (12), r32000bps (13), r57600bps (14), r115200bps(15), r128000bps(16), notConnected (100) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the port speed. The 16,32,48,56,64 and 128 kbps rates are applicable only for Sync protocol. The 57.6 and 115.2 kbps rates are applicable only for Async protocol. notConnected= 0 rate." ::= {prtExHsrCnfgEntry 6} prtExHsrDataBits OBJECT-TYPE SYNTAX INTEGER { d5bits (1), d6bits (2), d7bits (3), d8bits (4), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Data Bits. This object is applicable for Async protocol only." ::= {prtExHsrCnfgEntry 7} prtExHsrParity OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3), odd (4), even(5), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "- For HS-R card, this object indicates if the parity bit is needed or not. Therefore, the 'no' and 'yes; values are applicable. - For HS-S12, HS-U12, the parity type is selected: no, odd, even. This object is applicable for Async protocol only." ::= { prtExHsrCnfgEntry 8} prtExHsrStopBits OBJECT-TYPE SYNTAX INTEGER { stopBits1Bit (1), stopBits2Bits (2), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the minimum number of stop bits in the tx async frame. This object is applicable for Async protocol only." ::= { prtExHsrCnfgEntry 9} prtExHsrCts OBJECT-TYPE SYNTAX INTEGER { on (2), rts (3), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "CTS. This object is applicable for Async protocol only." ::= {prtExHsrCnfgEntry 10} prtExHsrClkMode OBJECT-TYPE SYNTAX INTEGER { dce (1), extDce (2), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Clock mode. This object is applicable for Sync protocol only." ::= { prtExHsrCnfgEntry 11} prtExHsrLinkTo OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "It indicates the slot of the main link card to which the HS-R card is mapped. notApplicable - for HS-U/1 internal ports. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort." ::= {prtExHsrCnfgEntry 12} prtExHsrDcdDsr OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), local (2), endToEnd (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "DCD & DSR." ::= {prtExHsrCnfgEntry 13} prtExHsrOperMode OBJECT-TYPE SYNTAX INTEGER { normal (2), unidirectRx (3), broadcast (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the operation mode of the port. normal = bi-directional (Tx/Rx) unidirectRx = unidirectional Rx. broadcast = Tx upon request." ::= {prtExHsrCnfgEntry 14} prtExHsrRtsDtr OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), local (2), endToEnd (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "RTS & DTR." ::= {prtExHsrCnfgEntry 15} prtExHsrLlbEnable OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disabled (2), enabled (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable LLB." ::= {prtExHsrCnfgEntry 16} prtExHsrRlbEnable OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disabled (2), enabled (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable RLB." ::= {prtExHsrCnfgEntry 17} prtExHsrRateAdapt OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), proprietary (2), v110 (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Rate Adaptation - takes a low rate and adapts it to 64Kbps. This object specifies the means this adaptation is done by." ::= {prtExHsrCnfgEntry 18} prtExHsrRemoteModem OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), asmi31 (2), asmi31s2 (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Remote modem. asmi31s2 = ASMi-31/2 " ::= {prtExHsrCnfgEntry 19} -- -- Megaplex?000/?004 MBE port configuration -- prtExMbeCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtExMbeCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= {prtMbeCnfg 1} prtExMbeCnfgEntry OBJECT-TYPE SYNTAX PrtExMbeCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtExMbeCnfgIdx, prtExMbeSltIdx, prtExMbePrtIdx } ::= { prtExMbeCnfgTable 1} PrtExMbeCnfgEntry ::= SEQUENCE { prtExMbeCnfgIdx Integer32, prtExMbeSltIdx INTEGER, prtExMbePrtIdx INTEGER, prtExMbeLan INTEGER } prtExMbeCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg" ::= {prtExMbeCnfgEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. prtExMbeSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid." ::= {prtExMbeCnfgEntry 2} prtExMbePrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) } MAX-ACCESS read-only STATUS current DESCRIPTION "A unique port identifier within the card." ::= {prtExMbeCnfgEntry 3} prtExMbeLan OBJECT-TYPE SYNTAX INTEGER { remote (1), main (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the MBE port is operated as main or remote bridge." ::= {prtExMbeCnfgEntry 4} prtInMbeCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtInMbeCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= {prtMbeCnfg 2} prtInMbeCnfgEntry OBJECT-TYPE SYNTAX PrtInMbeCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtInMbeCnfgIdx, prtInMbeSltIdx, prtInMbePrtIdx } ::= { prtInMbeCnfgTable 1} PrtInMbeCnfgEntry ::= SEQUENCE { prtInMbeCnfgIdx Integer32, prtInMbeSltIdx INTEGER, prtInMbePrtIdx INTEGER, prtInMbeConnect INTEGER, prtInMbeRate INTEGER, prtInMbeLinkTo INTEGER } prtInMbeCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg" ::= {prtInMbeCnfgEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. prtInMbeSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid." ::= {prtInMbeCnfgEntry 2} prtInMbePrtIdx OBJECT-TYPE SYNTAX INTEGER { inPrt1 (101) } MAX-ACCESS read-only STATUS current DESCRIPTION "A unique port identifier within the card." ::= {prtInMbeCnfgEntry 3} prtInMbeConnect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port should be considered in any of the mux algorithms." ::= {prtInMbeCnfgEntry 4} prtInMbeRate OBJECT-TYPE SYNTAX INTEGER { r1x64eq64Kbps (1), r2x64eq128Kbps (2), r3x64eq192Kbps (3), r4x64eq256Kbps (4), r5x64eq320Kbps (5), r6x64eq384Kbps (6), r7x64eq448Kbps (7), r8x64eq512Kbps (8), r9x64eq576Kbps (9), r10x64eq640Kbps (10), r11x64eq704Kbps (11), r12x64eq768Kbps (12), r13x64eq832Kbps (13), r14x64eq896Kbps (14), r15x64eq960Kbps (15), r16x64eq1024Kbps(16), r17x64eq1088Kbps(17), r18x64eq1152Kbps(18), r19x64eq1216Kbps(19), r20x64eq1280Kbps(20), r21x64eq1344Kbps(21), r22x64eq1408Kbps(22), r23x64eq1472Kbps(23), r24x64eq1536Kbps(24) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the port speed." ::= {prtInMbeCnfgEntry 5} prtInMbeLinkTo OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "It indicates the slot of the main link card to which the MBE card is mapped. In the ?004 Unit the entries io6(10)..io16) are not valid. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort." ::= {prtInMbeCnfgEntry 6} -- -- Megaplex?000/?004 TRE port configuration -- prtExTreCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtExTreCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= {prtTreCnfg 1} prtExTreCnfgEntry OBJECT-TYPE SYNTAX PrtExTreCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtExTreCnfgIdx, prtExTreSltIdx, prtExTrePrtIdx } ::= { prtExTreCnfgTable 1} PrtExTreCnfgEntry ::= SEQUENCE { prtExTreCnfgIdx Integer32, prtExTreSltIdx INTEGER, prtExTrePrtIdx INTEGER, prtExTreLan INTEGER, prtExTreLanRate INTEGER } prtExTreCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg" ::= {prtExTreCnfgEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. prtExTreSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid." ::= {prtExTreCnfgEntry 2} prtExTrePrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) } MAX-ACCESS read-only STATUS current DESCRIPTION "A unique port identifier within the card." ::= {prtExTreCnfgEntry 3} prtExTreLan OBJECT-TYPE SYNTAX INTEGER { remote (1), main (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the TRE port is operated as main or remote bridge. Default=remote." ::= {prtExTreCnfgEntry 4} prtExTreLanRate OBJECT-TYPE SYNTAX INTEGER { r4M (1), r16M (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the Rate of the TRE port in Mbit/sec. Default-r4M." ::= {prtExTreCnfgEntry 5} prtInTreCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtInTreCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= {prtTreCnfg 2} prtInTreCnfgEntry OBJECT-TYPE SYNTAX PrtInTreCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtInTreCnfgIdx, prtInTreSltIdx, prtInTrePrtIdx } ::= { prtInTreCnfgTable 1} PrtInTreCnfgEntry ::= SEQUENCE { prtInTreCnfgIdx Integer32, prtInTreSltIdx INTEGER, prtInTrePrtIdx INTEGER, prtInTreConnect INTEGER, prtInTreRate INTEGER, prtInTreLinkTo INTEGER } prtInTreCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg" ::= {prtInTreCnfgEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. prtInTreSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid." ::= {prtInTreCnfgEntry 2} prtInTrePrtIdx OBJECT-TYPE SYNTAX INTEGER { inPrt1 (101) } MAX-ACCESS read-only STATUS current DESCRIPTION "A unique port identifier within the card." ::= {prtInTreCnfgEntry 3} prtInTreConnect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port should be considered in any of the mux algorithms." ::= {prtInTreCnfgEntry 4} prtInTreRate OBJECT-TYPE SYNTAX INTEGER { r1x56eq56Kbps (1), r1x64eq64Kbps (2), r2x56eq112Kbps (3), r2x64eq128Kbps (4), r3x56eq168Kbps (5), r3x64eq192Kbps (6), r4x56eq224Kbps (7), r4x64eq256Kbps (8), r5x56eq280Kbps (9), r5x64eq320Kbps (10), r6x56eq336Kbps (11), r6x64eq384Kbps (12), r7x56eq392Kbps (13), r7x64eq448Kbps (14), r8x56eq448Kbps (15), r8x64eq512Kbps (16), r9x56eq504Kbps (17) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the port speed." ::= {prtInTreCnfgEntry 5} prtInTreLinkTo OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "It indicates the slot of the main link card to which the MBE card is mapped. In the ?004 Unit the entries io6(10)..io16) are not valid. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort." ::= {prtInTreCnfgEntry 6} -- Packet VC cards. -- This table is used for compressed voice cards with 4/8 ports. -- prtExPVc4CnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtExPVc4CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= { prtPVc4Cnfg 1} prtExPVc4CnfgEntry OBJECT-TYPE SYNTAX PrtExPVc4CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtExPVc4CnfgIdx, prtExPVc4SltIdx, prtExPVc4PrtIdx } ::= { prtExPVc4CnfgTable 1} PrtExPVc4CnfgEntry ::= SEQUENCE { prtExPVc4CnfgIdx Integer32, prtExPVc4SltIdx INTEGER, prtExPVc4PrtIdx INTEGER, prtExPVc4PrtType INTEGER, prtExPVc4Connect INTEGER, prtExPVc4IfType INTEGER, prtExPVc4TxGain Integer32, prtExPVc4RxGain Integer32, prtExPVc4MaxRate INTEGER, prtExPVc4Tc INTEGER, prtExPVc4Oos INTEGER, prtExPVc4EchoCanceler INTEGER, prtExPVc4VarDelay Integer32, prtExPVc4CongLevel Integer32, prtExPVc4Wire INTEGER, prtExPVc4ExtensionType INTEGER, prtExPVc4ExtensionNumber DisplayString, prtExPVc4OutPulsing INTEGER, prtExPVc4HuntGroupMb INTEGER, prtExPVc4HuntGroupIdx Integer32, prtExPVc4AutoFaxMode INTEGER, prtExPVc4FaxRate INTEGER, prtExPVc4SeizeAck INTEGER, prtExPVc4SignalingProtocol INTEGER, prtExPVc4DelayStart Integer32, prtExPVc4WinkMinDuration Integer32, prtExPVc4WinkMaxDuration Integer32, prtExPVc4GenerateTone INTEGER, prtExPVc4CodingLaw INTEGER, prtExPVc4GenerateRingBack INTEGER, prtExPVc4ChannelId Integer32, prtExPVc4PortConnection INTEGER, prtExPVc4CoderAndRate INTEGER, prtExPVc4DestinationNum DisplayString, prtExPVc4DtmfRelay INTEGER, prtExPVc4DiscOnSilence Integer32, prtExPVc4DynamicJitter INTEGER, prtExPVc4EandMType INTEGER } prtExPVc4CnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg" ::= {prtExPVc4CnfgEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. prtExPVc4SltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted." ::= {prtExPVc4CnfgEntry 2} prtExPVc4PrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4), inPrt1(101), inPrt2(102), inPrt3(103), inPrt4(104), inPrt5(105), inPrt6(106), inPrt7(107), inPrt8(108) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the port number in the selected card (slot)." ::= {prtExPVc4CnfgEntry 3} prtExPVc4PrtType OBJECT-TYPE SYNTAX INTEGER { eAndM (1), fxo (2), fxs (3), internal(4), s0 (5), u (6), sQsig (7), uQsig (8) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the type of the selected port. In Mx 30/300 phase 4: s0 & u are for Voice over ISDN. In MX 30/300 phase 5: sQsig & uQsig are used for Voice over ISDN with Qsig option. In MX MVC4 voice cards, each pair of ports 1-2, 3-4 may have a different type: E&M, FXO, FXS. In MVC4 compressed voice cards ports 1..4 have the same interface for all ports. In MVC8 compressed voice cards each group of ports 1..4, 5..8 may have a different type: E&M, FXO, FXS." ::= {prtExPVc4CnfgEntry 4} prtExPVc4Connect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port should be considered in any of the mux algorithms." ::= {prtExPVc4CnfgEntry 5} prtExPVc4IfType OBJECT-TYPE SYNTAX INTEGER { unknown (1), eAndM4wires (2), eAndM2wires (3), fxoGnd (4), fxoLoop (5), fxsGnd (6), fxsLoop (7), e1Framer (8), e1Slave (9), t1Framer (10), t1Slave (11) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the interface type of the port. eAndM4wires and eAndM2wires - are valid only for E&M port type eAndM4wires - means 2/4 wires fxoGnd and fxoLoop - are valid only for FXO port type fxsGnd and fxsLoop - are valid only for FXS port type e1Framer, e1Slave, t1Framer, t1Slave - are applicable for the mvc4Pbx cards only." ::= {prtExPVc4CnfgEntry 6} prtExPVc4TxGain OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Transmission gain in dBm." ::= {prtExPVc4CnfgEntry 7} prtExPVc4RxGain OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Reception gain in dBm." ::= {prtExPVc4CnfgEntry 8} prtExPVc4MaxRate OBJECT-TYPE SYNTAX INTEGER { notConnected (1), r4800bps (2), r7200bps (3), r9600bps (4), notApplicatble (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Voice rate." ::= {prtExPVc4CnfgEntry 9} prtExPVc4Tc OBJECT-TYPE SYNTAX INTEGER { t1sec (1), t2sec (2), t3sec (3), t4sec (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Time interval for CIR control, in seconds. The value will be the same for all cards' ports." ::= {prtExPVc4CnfgEntry 10} prtExPVc4Oos OBJECT-TYPE SYNTAX INTEGER { notSupported (2), forcedIdle (3), forcedBusy (4), busyIdle (5), idleBusy (6) } MAX-ACCESS read-write STATUS current DESCRIPTION "Handling type, when connection is lost." ::= {prtExPVc4CnfgEntry 11} prtExPVc4EchoCanceler OBJECT-TYPE SYNTAX INTEGER { off (2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Echo canceler activation." ::= {prtExPVc4CnfgEntry 12} prtExPVc4VarDelay OBJECT-TYPE SYNTAX Integer32 (0..300) MAX-ACCESS read-write STATUS current DESCRIPTION "Maximum variant delay of the FR network, in msec." ::= {prtExPVc4CnfgEntry 13} prtExPVc4CongLevel OBJECT-TYPE SYNTAX Integer32 (0..70) MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the level of delayed data in precents of total available dynamic memory, for which the port will start to operate as congested. The resolution of the parameter is 5%." ::= {prtExPVc4CnfgEntry 14} prtExPVc4Wire OBJECT-TYPE SYNTAX INTEGER { w2wire (1), w4wire (2), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the wiring of the E&M port. It is applicable only for E&M card type." ::= {prtExPVc4CnfgEntry 15} prtExPVc4ExtensionType OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), forceConnect(2), voiceSwitching(3), transparent(4), transparentPlus(5), ipForceConnect(6), permanentDial (7), autoAccept (8) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the type of extension relevant for this port. ipForceConnect (6) is used for automatic connection or automatic dialing when the phone is off hook (hot line). permanentDial (7) means that the call is established upon power up. The hook may be on or off. Permanent Dialing can be used when there is no signaling. autoAccept (8) means that the called party in the Permanent Dialing will accept the call from the remote side automatically upon on or off hook." ::= {prtExPVc4CnfgEntry 16} prtExPVc4ExtensionNumber OBJECT-TYPE SYNTAX DisplayString (SIZE(2)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is the extension number of this port. This field is relevant only when the extension type is voice switching and is read only if the port is member of a hunt group." ::= {prtExPVc4CnfgEntry 17} prtExPVc4OutPulsing OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), no(2), yes(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This field indicates whether to outpulse the received digits. It is notApplicable(1) when the extension type is forceConnect(2)." ::= {prtExPVc4CnfgEntry 18} prtExPVc4HuntGroupMb OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), no(2), yes(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates if this port belongs to an hunt group." ::= {prtExPVc4CnfgEntry 19} prtExPVc4HuntGroupIdx OBJECT-TYPE SYNTAX Integer32(0..10) MAX-ACCESS read-write STATUS current DESCRIPTION "If it belongs to an hunt group, this fields indicates the index of the relevant hunt group. 0 = notApplicable " ::= {prtExPVc4CnfgEntry 20} prtExPVc4AutoFaxMode OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), no(2), yes(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates if the system will switch automatically to FAX mode when detecting FAX activity. Default=Yes." ::= {prtExPVc4CnfgEntry 21} prtExPVc4FaxRate OBJECT-TYPE SYNTAX INTEGER { notConnected (1), r4800bps (2), r7200bps (3), r9600bps (4), r12000bps (5), r14400bps (6), r2400bps (7) } MAX-ACCESS read-write STATUS current DESCRIPTION "FAX initial rate. Default=9600 bps." ::= {prtExPVc4CnfgEntry 22} prtExPVc4SeizeAck OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter shows whether the device will acknowledge a seize signal (On/Off Hook). When the value is set to yes(3) & the device receives an on/off hook signal it will transmit back an on/off hook signal. When the value is set to no(2) & the device receives an on/off hook signal it will NOT transmit back an on/off hook signal. Example: If Seize Ack Parameter = YES, when the MVC.4 receives a seize signal (Off Hook) from the PBX it will send an Off Hook to the PBX. The Seize Parameter is relevant for all the following cards: MVC-4 MVC-4/E1-Framer MVC-4/T1-DSU-Framer MVC-4/T1-CSU-Framer MVC-4/E1-SLAVE MVC-4/T1-SLAVE Default values: Analog FXS - No (value can't be changed). Analog FXO - Yes (value can't be changed). Analog E&M - No (values NO/YES). Digital E1/T1 Framer & Slave - No." ::= {prtExPVc4CnfgEntry 23} prtExPVc4SignalingProtocol OBJECT-TYPE SYNTAX INTEGER { delayStart (2), immediateStart (3), winkStart (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The signaling protocol that will be used between the PABX & the voice port. Delay Start Protocol: the line is seized by sending an Off hook signal and after a delay, if the called party is available (On hook) DTMF (Dual Tone Multi Frequency) digits are sent towards the called party. Immediate Start Protocol: the line is seized by sending an Off Hook signal and immediately DTMF digits are sent towards the called party. Wink start protocol: the line is seized by sending an Off Hook signal and then the called party sends a short Off Hook wink signal. Now the calling party starts sending DTMF digits." ::= {prtExPVc4CnfgEntry 24} prtExPVc4DelayStart OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter is used only for Delay Protocol. This is the time that the calling party will wait after sending an Off hook signal and before sending DTMF digits to the called party. The delay values are 100..5000 msec in intervals of 100 msec." ::= {prtExPVc4CnfgEntry 25} prtExPVc4WinkMinDuration OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter is used only for Wink Protocol. Min Duration of the Wink Signal (off hook duration from the called party). Legal values: 40..400 msec in intervals of 10 msec." ::= {prtExPVc4CnfgEntry 26} prtExPVc4WinkMaxDuration OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter is used only for Wink Protocol. Max Duration of the Wink Signal (off hook duration from the called party). Legal values: 40..400 msec in intervals of 10 msec." ::= {prtExPVc4CnfgEntry 27} prtExPVc4GenerateTone OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter indicates whether the device (MX or MPH) should generate dial tones for the channel. If the value is yes (3), it generates dial tones. If the value is no (2), the connected equipment will generate dial tones. For example for some ISDN sets the dial tone is generated by the phone itself while for others sets it is generated by the MX." ::= {prtExPVc4CnfgEntry 28} prtExPVc4CodingLaw OBJECT-TYPE SYNTAX INTEGER { aLAW (1), uLAW (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the Method/Law for decoding/encoding the voice information. aLaw(1) is the standard Law for E1 links. uLaw(2) is the standard Law for T1 links. This object is equal for all the ports in the specific module because of HW limitations" ::= {prtExPVc4CnfgEntry 29} prtExPVc4GenerateRingBack OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Determines whether the Ring Back tone is generated locally or from the remote end. The default is - NO (Meaning coming from the remote end). Yes means that the Ring Back Tone is generated locally. Applicable only for Force Connect." ::= {prtExPVc4CnfgEntry 30} prtExPVc4ChannelId OBJECT-TYPE SYNTAX Integer32 (0..256) MAX-ACCESS read-write STATUS current DESCRIPTION "Channel Identifier. According to FRF11 each voice port that works as force connect should add a CH Id after the DLCI in the frame header. Default : 1 Applicable only for Force Connect. Not Applicable value will be 0." ::= {prtExPVc4CnfgEntry 31} prtExPVc4PortConnection OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), line (2), trunk (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Port connection determines whether the port is connected to a PABX (Trunk) or to Telephone set (Line) . It determines whether to send certain messages to the port or not. If the type is LINE then the port generates a ring back tone , if TRUNK it doesn't (The PBX does it)." ::= {prtExPVc4CnfgEntry 32} prtExPVc4CoderAndRate OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), g7231r6300BPS (2), g7231r5300BPS (3), g729A8KBPS (4), g711aLAW (5), g711uLAW (6), g726r16KBPS (7), g726r24KBPS (8), g726r32KBPS (9), g726r40KBPS (10), g727r16KBPS (11), g727r24r16KBPS (12), g727r24KBPS (13), g727r16r32KBPS (14), g727r32r24KBPS (15), g727r32KBPS (16), g727r40r16KBPS (17), g727r40r24KBPS (18), g727r40r32KBPS (19), transparent (20), netcoder6400BPS (21), netcoder7200BPS (22), netcoder8KBPS (23), netcoder8800BPS (24), netcoder9600BPS (25) } MAX-ACCESS read-write STATUS current DESCRIPTION "Coder and Rate for the Voice Compression. Relevant for MVC-8 card only." ::= {prtExPVc4CnfgEntry 33} prtExPVc4DestinationNum OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The destination phone number: 0 to 22 digits. Applicable for Auto Dial - ipForceConnect(6), Permanent Dial and Auto Accept Extension Types. Default: Null String" ::= {prtExPVc4CnfgEntry 34} prtExPVc4DtmfRelay OBJECT-TYPE SYNTAX INTEGER { disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "When DTMF RELAY is disabled, the DTMF digits (dialed by the user) are transmitted as compressed voice and in the remote unit are decompressed. When DTMF RELAY is enabled, the DTMF digits are detected at the near side and not transmitted as voice. Instead, only an indication of what digits were dialed are transmitted and in the far end the tone is regenerated." ::= {prtExPVc4CnfgEntry 35} prtExPVc4DiscOnSilence OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "No. of silenced seconds after which the call will be disconected. A value of 0 means that there will be no disconnect when there is silence. Possible values: 0 - 900 sec." ::= {prtExPVc4CnfgEntry 36} prtExPVc4DynamicJitter OBJECT-TYPE SYNTAX INTEGER { disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The MVC8 uses two mechanisms to overcome the network delay. The first one is a static jitter buffer which holds a constant buffer of up to 300 Msec and can be controled by the JITTER parameter (prtExPVc4VarDelay). The second one is the dynamic jitter which calculates, in real time, the network delay and handles a jitter buffer dynamically. The dynamic mechanism that is implemented in MVC8, was intended to overcome network delay yet when the network bursts, the MVC8 dynamic mechanism is not able to overcome the delay. Therefore it is better not to use the dynamic jitter (DISABLE - should be the default) where bursts may occur often." ::= {prtExPVc4CnfgEntry 37} prtExPVc4EandMType OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), type1 (2), type2 (3), type3 (4), ssdc5 (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "This is the signaling type on the E&M analog side. The analog signaling includes voltage, no. of pins and other parameters." ::= {prtExPVc4CnfgEntry 38} -- -- Packet VC4 card -- External port Dlci table -- prtExPVc4DlciTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtExPVc4DlciEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only at the TmpCnfg entry." ::= {prtPVc4Cnfg 2} prtExPVc4DlciEntry OBJECT-TYPE SYNTAX PrtExPVc4DlciEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtExPVc4DlciCnfgIdx, prtExPVc4DlciSltIdx, prtExPVc4DlciPrtIdx} ::= { prtExPVc4DlciTable 1} PrtExPVc4DlciEntry ::= SEQUENCE { prtExPVc4DlciCnfgIdx Integer32, prtExPVc4DlciSltIdx INTEGER, prtExPVc4DlciPrtIdx INTEGER, prtExPVc4DlciValid INTEGER, prtExPVc4DlciIConSlt INTEGER, prtExPVc4DlciIConPrt INTEGER, prtExPVc4DlciIConDlci Integer32, prtExPVc4DlciTxBc INTEGER, prtExPVc4DlciTxBe INTEGER, prtExPVc4DlciRxBc INTEGER, prtExPVc4DlciRxBe INTEGER, prtExPVc4DlciPriority Integer32, prtExPVc4DlciStatus INTEGER } prtExPVc4DlciCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. " ::= { prtExPVc4DlciEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. prtExPVc4DlciSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid" ::= { prtExPVc4DlciEntry 2} prtExPVc4DlciPrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique internal port number. VC4 cards have four external ports." ::= { prtExPVc4DlciEntry 3} prtExPVc4DlciValid OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the attributes in this entry are valid or not. The user can add/delete pvc (dlci to dlci connection) by modifing this object" ::= { prtExPVc4DlciEntry 4} prtExPVc4DlciIConSlt OBJECT-TYPE SYNTAX INTEGER { noConnect (2), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique slot position In the Mux (Agent) where the dlci is routed to. In the ?004 Unit the entries io6(10)..io16) are not valid" ::= { prtExPVc4DlciEntry 5} prtExPVc4DlciIConPrt OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) , exPrt7 (7) , exPrt8 (8) , exPrt9 (9) , exPrt10 (10) , noConnect (100), inPrt1 (101) , inPrt2 (102) , inPrt3 (103) , inPrt4 (104) , inPrt5 (105) , inPrt6 (106) , inPrt7 (107) , inPrt8 (108) , inPrt9 (109) , inPrt10 (110) , inPrt11 (111) , inPrt12 (112) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique port id which the dlci is routed to." ::= { prtExPVc4DlciEntry 6} prtExPVc4DlciIConDlci OBJECT-TYPE SYNTAX Integer32 (1..991) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique internal connection dlci number, the dlci is routed to." ::= { prtExPVc4DlciEntry 7} prtExPVc4DlciTxBc OBJECT-TYPE SYNTAX INTEGER { full (1), zero (2), txBc9600bps (3), txBc14400bps (4), txBc19200bps (5), txBc28800bps (6), txBc32000bps (7), txBc38400bps (8), txBc48000bps (9), txBc56000bps (10), txBc57600bps (11), txBc64Kbps (12), txBc128Kbps (13), txBc192Kbps (14), txBc256Kbps (15), txBc320Kbps (16), txBc384Kbps (17), txBc448Kbps (18), txBc512Kbps (19), txBc768Kbps (20), txBc1024Kbps (21), -- --KM30 ; KM300 additional rates -- txBc16000bps (25), txBc112Kbps (26) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique Tx committed bandwidth on the user transmit line (or at the port receive line)." ::= { prtExPVc4DlciEntry 8} prtExPVc4DlciTxBe OBJECT-TYPE SYNTAX INTEGER { full (1), zero (2), txBe9600bps (3), txBe14400bps (4), txBe19200bps (5), txBe28800bps (6), txBe32000bps (7), txBe38400bps (8), txBe48000bps (9), txBe56000bps (10), txBe57600bps (11), txBe64Kbps (12), txBe128Kbps (13), txBe192Kbps (14), txBe256Kbps (15), txBe320Kbps (16), txBe384Kbps (17), txBe448Kbps (18), txBe512Kbps (19), txBe768Kbps (20), txBe1024Kbps (21), -- --KM30 ; KM300 additional rates -- txBc16000bps (25), txBc112Kbps (26) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique Tx excess bandwidth on the user transmit line (or at the port receive line)." ::= { prtExPVc4DlciEntry 9} prtExPVc4DlciRxBc OBJECT-TYPE SYNTAX INTEGER { full (1), zero (2), rxBc9600bps (3), rxBc14400bps (4), rxBc19200bps (5), rxBc28800bps (6), rxBc32000bps (7), rxBc38400bps (8), rxBc48000bps (9), rxBc56000bps (10), rxBc57600bps (11), rxBc64Kbps (12), rxBc128Kbps (13), rxBc192Kbps (14), rxBc256Kbps (15), rxBc320Kbps (16), rxBc384Kbps (17), rxBc448Kbps (18), rxBc512Kbps (19), rxBc768Kbps (20), rxBc1024Kbps (21), -- --KM30 ; KM300 additional rates -- rxBc16000bps (25), rxBc112Kbps (26) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique Rx committed bandwidth on the user receive line (or at the port transmit line)." ::= { prtExPVc4DlciEntry 10} prtExPVc4DlciRxBe OBJECT-TYPE SYNTAX INTEGER { full (1), zero (2), rxBe9600bps (3), rxBe14400bps (4), rxBe19200bps (5), rxBe28800bps (6), rxBe32000bps (7), rxBe38400bps (8), rxBe48000bps (9), rxBe56000bps (10), rxBe57600bps (11), rxBe64Kbps (12), rxBe128Kbps (13), rxBe192Kbps (14), rxBe256Kbps (15), rxBe320Kbps (16), rxBe384Kbps (17), rxBe448Kbps (18), rxBe512Kbps (19), rxBe768Kbps (20), rxBe1024Kbps (21), -- --KM30 ; KM300 additional rates -- rxBc16000bps (25), rxBc112Kbps (26) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique Rx excess bandwidth on the user receive line (or at the port transmit line)." ::= { prtExPVc4DlciEntry 11} prtExPVc4DlciPriority OBJECT-TYPE SYNTAX Integer32 (6..8) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique priority of the pvc. 6 is the lowest priority and 8 is the highest priority." ::= { prtExPVc4DlciEntry 12} prtExPVc4DlciStatus OBJECT-TYPE SYNTAX INTEGER { disconnected (1), connected (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the status of the pvc. The status is disconnected(1) when one of the sides is programmed as not connected" ::= { prtExPVc4DlciEntry 13} -- -- Megaplex ?000/?004 LS-6 TDM I/O family card include: -- Ls6, Ls6V1/E, Ls6V1/O, Ls6V1/S, Ls6V2/E, Ls6V2/O, Ls6V2/S, -- Ls6Vf/E, Ls6Vf/O, Ls6Vf/S -- --prtExLs6CnfgTable OBJECT IDENTIFIER ::= {prtLs6Cnfg 1} --prtExLs6VCnfgTable OBJECT IDENTIFIER ::= {prtLs6Cnfg 2} --prtInLs6CnfgTable OBJECT IDENTIFIER ::= {prtLs6Cnfg 3} --prtExLs6CnfgTable defines the parameters of the -- LS-6 cards family external Data ports (1-6) ; LS-12 (1-12) prtExLs6CnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtExLs6CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= {prtLs6Cnfg 1} prtExLs6CnfgEntry OBJECT-TYPE SYNTAX PrtExLs6CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtExLs6CnfgIdx, prtExLs6SltIdx, prtExLs6PrtIdx } ::= {prtExLs6CnfgTable 1} PrtExLs6CnfgEntry ::= SEQUENCE { prtExLs6CnfgIdx Integer32, prtExLs6SltIdx INTEGER, prtExLs6PrtIdx INTEGER, prtExLs6Connect INTEGER, prtExLs6Protocol INTEGER, prtExLs6Rate INTEGER, prtExLs6ClkMode INTEGER, prtExLs6CtrlSignal INTEGER, prtExLs6DataBits INTEGER, prtExLs6Cts INTEGER, prtExLs6LinkToInternal INTEGER } prtExLs6CnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg" ::= {prtExLs6CnfgEntry 1} prtExLs6SltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid." ::= {prtExLs6CnfgEntry 2} prtExLs6PrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) , exPrt7 (7) , exPrt8 (8) , exPrt9 (9) , exPrt10 (10) , exPrt11 (11) , exPrt12 (12) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port index." ::= {prtExLs6CnfgEntry 3} prtExLs6Connect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port should be considered in any of the mux algorithms." ::= {prtExLs6CnfgEntry 4} prtExLs6Protocol OBJECT-TYPE SYNTAX INTEGER { sync (2), async (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the protocol. async - can be selected only for ports 1-2." ::= {prtExLs6CnfgEntry 5} prtExLs6Rate OBJECT-TYPE SYNTAX INTEGER { r300bps (2), r600bps (3), r1200bps (4), r2400bps (5), r4800bps (6), r7200bps (7), r8000bps (8), r9600bps (9), r14400bps (10), r16000bps (11), r19200bps (12), r24000bps (13), r28800bps (14), r32000bps (15), r38400bps (16), r48000bps (17), r56000bps (18), r57600bps (19), r64000bps (20) } MAX-ACCESS read-write STATUS current DESCRIPTION "Port rates in bps. g1 - contains the values : (2)-(6),(9),(12),(16) g2 - contains the values : (7),(10),(14),(19) g3 - contains the values : (8),(11),(13),(15),(17),(18),(20); it is not applicable when using Async protocol. Rates of pair ports (1-2, 3-4, 5-6) must be from the same group." ::= {prtExLs6CnfgEntry 6} prtExLs6ClkMode OBJECT-TYPE SYNTAX INTEGER { dce (1), extDce (2), dte1 (3), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique port operation clock mode. It is applicable for Sync protocol only ." ::= {prtExLs6CnfgEntry 7} prtExLs6CtrlSignal OBJECT-TYPE SYNTAX INTEGER { local (2), rts (3), dtrAndRts (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Control Signal." ::= {prtExLs6CnfgEntry 8} prtExLs6DataBits OBJECT-TYPE SYNTAX INTEGER { d6bits (1), d7bits (2), d8bits (3), d9bits (4), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Data Bits. This object is applicable for Async protocol only." ::= {prtExLs6CnfgEntry 9} prtExLs6Cts OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), on (2), rts (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the CTS control line operation mode." ::= {prtExLs6CnfgEntry 10} prtExLs6LinkToInternal OBJECT-TYPE SYNTAX INTEGER { inPrt1 (101) , inPrt2 (102) , notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates which internal port of the card, the external port is linked to." ::= {prtExLs6CnfgEntry 11} --prtExLs6VCnfgTable defines the parameters of the -- LS-6 cards family external Voice & FAX ports (7-8) prtExLs6VCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtExLs6VCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= {prtLs6Cnfg 2} prtExLs6VCnfgEntry OBJECT-TYPE SYNTAX PrtExLs6VCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtExLs6VCnfgIdx, prtExLs6VSltIdx, prtExLs6VPrtIdx } ::= {prtExLs6VCnfgTable 1} PrtExLs6VCnfgEntry ::= SEQUENCE { prtExLs6VCnfgIdx Integer32, prtExLs6VSltIdx INTEGER, prtExLs6VPrtIdx INTEGER, prtExLs6VConnect INTEGER, prtExLs6VRate INTEGER, prtExLs6VEchoCanceler INTEGER, prtExLs6VIfType INTEGER, prtExLs6VTxGain Integer32, prtExLs6VRxGain Integer32, prtExLs6VOos INTEGER } prtExLs6VCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg" ::= {prtExLs6VCnfgEntry 1} prtExLs6VSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid." ::= {prtExLs6VCnfgEntry 2} prtExLs6VPrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt7 (7) , exPrt8 (8) } MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier of the port, within the card." ::= {prtExLs6VCnfgEntry 3} prtExLs6VConnect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port should be considered in any of the mux algorithms." ::= {prtExLs6VCnfgEntry 4} prtExLs6VRate OBJECT-TYPE SYNTAX INTEGER { r6400bps (2), r7200bps (3), r8000bps (4), r9600bps (5), r16000bps (6), r24000bps (7), r32000bps (8), r64000bps (9) } MAX-ACCESS read-write STATUS current DESCRIPTION "Rate (bps) used for FAX transmission and Voice coding." ::= {prtExLs6VCnfgEntry 5} prtExLs6VEchoCanceler OBJECT-TYPE SYNTAX INTEGER { off (2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Echo canceler activation." ::= {prtExLs6VCnfgEntry 6} prtExLs6VIfType OBJECT-TYPE SYNTAX INTEGER { w2wire (1), w4wire (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the interface type of the port. w4wire - is applicable only for E&M port type." ::= {prtExLs6VCnfgEntry 7} prtExLs6VTxGain OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Transmit gain in dBm. E&M - values range: -17 .. 8 FXO - values range: -16 .. 4 FXS - values range: -13 .. 8 " ::= {prtExLs6VCnfgEntry 8} prtExLs6VRxGain OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Receive gain in dBm. E&M - values range: -17 .. 2 FXO - values range: -17 .. -1 FXS - values range: -17 .. 2 " ::= {prtExLs6VCnfgEntry 9} prtExLs6VOos OBJECT-TYPE SYNTAX INTEGER { forcedIdle (1), forcedBusy (2), busyIdle (3), idleBusy (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Out of Service signaling mode." ::= {prtExLs6VCnfgEntry 10} -- Ls6 and Ls12 Internal composite channel parameters -- prtInLs6CnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtInLs6CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= {prtLs6Cnfg 3} prtInLs6CnfgEntry OBJECT-TYPE SYNTAX PrtInLs6CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtInLs6CnfgIdx, prtInLs6SltIdx, prtInLs6PrtIdx } ::= {prtInLs6CnfgTable 1} PrtInLs6CnfgEntry ::= SEQUENCE { prtInLs6CnfgIdx Integer32, prtInLs6SltIdx INTEGER, prtInLs6PrtIdx INTEGER, prtInLs6Connect INTEGER, prtInLs6TandemMode INTEGER, prtInLs6Rate INTEGER, prtInLs6RemoteType INTEGER, prtInLs6LinkTo INTEGER } prtInLs6CnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg" ::= {prtInLs6CnfgEntry 1} prtInLs6SltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid." ::= {prtInLs6CnfgEntry 2} prtInLs6PrtIdx OBJECT-TYPE SYNTAX INTEGER { inPrt1 (101), inPrt2 (102) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique internal port index." ::= {prtInLs6CnfgEntry 3} prtInLs6Connect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port should be considered in any of the mux algorithms. It also affects all the module considerations because the module has only one Internal interface which is the composite channel." ::= {prtInLs6CnfgEntry 4} prtInLs6TandemMode OBJECT-TYPE SYNTAX INTEGER { noTandem (1), tandemMaster (2), tandemSlave (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the Tandem Mode. tandemSlave - is valid only for an LS-6 card having on the (current slot-1) an LS-6 card with 'tandemMaster' mode." ::= {prtInLs6CnfgEntry 5} prtInLs6Rate OBJECT-TYPE SYNTAX INTEGER { r32Kbps (1), r56Kbps (2), r64Kpbs (3), r128Kbps (4), r256Kbps (5), r384Kbps (6), r192Kbps (7), r512Kbps (8), r768Kbps (9), r14400bps(10) } MAX-ACCESS read-write STATUS current DESCRIPTION "Main Rate in Kbps." ::= {prtInLs6CnfgEntry 6} prtInLs6RemoteType OBJECT-TYPE SYNTAX INTEGER { ls6 (1), km2kSlave (2), km2kStandalone (3), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Remote Type. notApplicable - when prtInLs6TandemMode=tandemSlave " ::= {prtInLs6CnfgEntry 7} prtInLs6LinkTo OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "It indicates the slot of the main link card to which the Ls6 card is mapped. In the ?004 Unit the entries io6(10)..io12(16) are not valid. notApplicable - when prtInLs6TandemMode=tandemSlave. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort. " ::= {prtInLs6CnfgEntry 8} -- -- Megaplex?000/?004 VC-3 TDM I/O family port. -- (VC3/E&M,VC3/FXO,VC3/FXS) -- -- --prtExVc3CnfgTable defines the parameters of the -- VC-3 and VF-3 cards family external ports prtExVc3CnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtExVc3CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= { prtVc3Cnfg 1} prtExVc3CnfgEntry OBJECT-TYPE SYNTAX PrtExVc3CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtExVc3CnfgIdx, prtExVc3SltIdx, prtExVc3PrtIdx } ::= { prtExVc3CnfgTable 1} PrtExVc3CnfgEntry ::= SEQUENCE { prtExVc3CnfgIdx Integer32, prtExVc3SltIdx INTEGER, prtExVc3PrtIdx INTEGER, prtExVc3Connect INTEGER, prtExVc3TransGain Integer32, prtExVc3ReceiveGain Integer32, prtExVc3Wire INTEGER, prtExVc3Rate INTEGER, prtExVc3EchoCanceler INTEGER } prtExVc3CnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg" ::= {prtExVc3CnfgEntry 1} prtExVc3SltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid." ::= {prtExVc3CnfgEntry 2} prtExVc3PrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) , exPrt2 (2) , exPrt3 (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier of the port, within the card." ::= {prtExVc3CnfgEntry 3} prtExVc3Connect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port should be considered in any of the mux algorithms." ::= {prtExVc3CnfgEntry 4} prtExVc3TransGain OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Transmit gain in dBm." ::= {prtExVc3CnfgEntry 5} prtExVc3ReceiveGain OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Receive gain in dBm." ::= {prtExVc3CnfgEntry 6} prtExVc3Wire OBJECT-TYPE SYNTAX INTEGER { w2wire (1), w4wire (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is equal for all the ports in the specific card because of HW limitations" ::= {prtExVc3CnfgEntry 7} prtExVc3Rate OBJECT-TYPE SYNTAX INTEGER { r9600bps (1), r4800bps (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Rate in bps." ::= {prtExVc3CnfgEntry 8} prtExVc3EchoCanceler OBJECT-TYPE SYNTAX INTEGER { off (2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Echo canceler activation. The value will be the same for all the card's external ports." ::= {prtExVc3CnfgEntry 9} --prtInVc3CnfgTable defines the parameters of the -- VC-3 or VF-3 cards family internal ports prtInVc3CnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtInVc3CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= { prtVc3Cnfg 2} prtInVc3CnfgEntry OBJECT-TYPE SYNTAX PrtInVc3CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtInVc3CnfgIdx, prtInVc3SltIdx, prtInVc3PrtIdx } ::= { prtInVc3CnfgTable 1} PrtInVc3CnfgEntry ::= SEQUENCE { prtInVc3CnfgIdx Integer32, prtInVc3SltIdx INTEGER, prtInVc3PrtIdx INTEGER, prtInVc3Connect INTEGER, prtInVc3Rate INTEGER, prtInVc3Oos INTEGER, prtInVc3LinkTo INTEGER } prtInVc3CnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg" ::= {prtInVc3CnfgEntry 1} prtInVc3SltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid." ::= {prtInVc3CnfgEntry 2} prtInVc3PrtIdx OBJECT-TYPE SYNTAX INTEGER { inPrt1 (101) } MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier of the port, within the card." ::= {prtInVc3CnfgEntry 3} prtInVc3Connect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port should be considered in any of the mux algorithms." ::= {prtInVc3CnfgEntry 4} prtInVc3Rate OBJECT-TYPE SYNTAX INTEGER { r32000bps (1), r16000bps (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Rate in bps." ::= {prtInVc3CnfgEntry 5} prtInVc3Oos OBJECT-TYPE SYNTAX INTEGER { forcedIdle (1), forcedBusy (2), busyIdle (3), idleBusy (4) } MAX-ACCESS read-write STATUS current DESCRIPTION " This object is equal for all the ports in the specific card because of HW limitations" ::= {prtInVc3CnfgEntry 6} prtInVc3LinkTo OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This attribute indicates the slot of the ML card to which the VC card is mapped. In the ?004 Unit the entries io6(10)..io12(16) are not valid. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort." ::= {prtInVc3CnfgEntry 7} -- -- Megaplex?000/?004 VC-3 TDM I/O family port. -- (VC-PBX, VC-PBX/T1,VC-PBX/E1) -- -- --prtExVcPbxCnfgTable defines the parameters of the -- VC-PBX or VF-PBX cards family external ports prtExVcPbxCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtExVcPbxCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= { prtVcPbxCnfg 1} prtExVcPbxCnfgEntry OBJECT-TYPE SYNTAX PrtExVcPbxCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtExVcPbxCnfgIdx, prtExVcPbxSltIdx, prtExVcPbxPrtIdx } ::= { prtExVcPbxCnfgTable 1} PrtExVcPbxCnfgEntry ::= SEQUENCE { prtExVcPbxCnfgIdx Integer32, prtExVcPbxSltIdx INTEGER, prtExVcPbxPrtIdx INTEGER, prtExVcPbxConnect INTEGER, prtExVcPbxGroup INTEGER, prtExVcPbxTransparent INTEGER, prtExVcPbxTransSignalTs Integer32, prtExVcPbxFrame INTEGER, prtExVcPbxRestoreTime INTEGER, prtExVcPbxLineCode INTEGER, prtExVcPbxLineLength INTEGER, prtExVcPbxLinkTo INTEGER, prtExVcPbxSignalOper INTEGER, prtExVcPbxIdleCode INTEGER } prtExVcPbxCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg" ::= {prtExVcPbxCnfgEntry 1} prtExVcPbxSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid." ::= {prtExVcPbxCnfgEntry 2} prtExVcPbxPrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) } MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier of the port, within the card." ::= {prtExVcPbxCnfgEntry 3} prtExVcPbxConnect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether the port should be considered in any of the mux algorithms." ::= {prtExVcPbxCnfgEntry 4} prtExVcPbxGroup OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "The group object links together several VC-PBX cards, concerning compression of the same input T1/E1 link time-slots. When ports of different slots have the same group, they are linked. When ports have a different group, they are not linked. For VC-PBX/T1 and E1 cards, this object is - their own IO Slot. In the ?004 Unit the entries io6(10)..io12(16) are not valid." ::= {prtExVcPbxCnfgEntry 5} prtExVcPbxTransparent OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether the Transparent transfer of Time-Slots is required or not. Time-Slots transferred by Transparent, will not be compressed. no - applicable only for VC-PBX/T1 and VC-PBX/E1 cards yes - applicable only for VC-PBX/T1 and VC-PBX/E1 cards notApplicable - only for VC-PBX cards." ::= {prtExVcPbxCnfgEntry 6} prtExVcPbxTransSignalTs OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the ML Time-Slot dedicated to the signaling of the PABX Transparent TSs. None = 255. When prtExVcPbxTransparent=no this object's value=None (255) When prtExVcPbxTransparent=notApplicable, this object's value=None (255). When prtExVcPbxTransparent=yes: - for VC-PBX/T1 ports, this object's valid values are 1..16 or None (255). - for VC-PBX/E1 ports, this object's value will be 16 or None (255)." ::= {prtExVcPbxCnfgEntry 7} prtExVcPbxFrame OBJECT-TYPE SYNTAX INTEGER { esfT1 (2), --> dsx1ESF sfT1 (3), --> dsx1D4 g732nE1 (4), --> dsx1E1 g732nE1CRC (5), --> dsx1E1-CRC g732sE1 (6), --> dsx1E1-MF g732sE1CRC (7), --> dsx1E1-MF-CRC notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is the frame parameter for T1/E1 interface. The user should select only the parameters which are relevant to the specific card: T1 values for the VC-PBX/T1 card. E1 values for the VC-PBX/E1 card. notApplicable - for the VC-PBX card. This parameter has the same values as dsx1LineType in T1/E1 MIB (RFC-1406). The parameters in dsx1LineType are: other (1) esfT1 dsx1ESF (2) sfT1 dsx1D4 (3) g732nE1 dsx1E1 (4) g732nE1CRC dsx1E1-CRC (5) g732sE1 dsx1E1-MF (6) g732sE1CRC dsx1E1-MF-CRC (7) " ::= {prtExVcPbxCnfgEntry 8} prtExVcPbxRestoreTime OBJECT-TYPE SYNTAX INTEGER { restoreT1secFast (2), restoreT10sec62411 (3), ccittE1 (4), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "The time passing from the disappearance of the loss of synchronization condition (red alarm) to the restoration of normal service. The options 1secFast(2) and 10sec62411(3) for E1 interfaces are proprietary implementation of the T1 standard to the E1 interface. ccittE1 - is applicable only for VC-PBX/E1 card notApplicable - is applicable for VC-PBX card" ::= {prtExVcPbxCnfgEntry 9} prtExVcPbxLineCode OBJECT-TYPE SYNTAX INTEGER { b7zsT1 (1), --> dsx1JBZS b8zsT1 (2), --> dsx1B8ZS transT1(3), --> dsx1AMI hdb3E1 (4), --> dsx1HDB3 notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is the line code parameter used for T1/E1 interface. The user should select only the parameters which are relevant to the specific card: T1 line code parameters for VC-PBX/T1 E1 line code parameters for VC-PBX/E1 notApplicable - for VC-PBX This parameter has the same values as dsx1LineCoding in T1/E1 MIB (RFC-1406). The parameters in dsx1LineCoding are: dsx1JBZS (1) dsx1B8ZS (2) dsx1HDB3 (3) dsx1ZBTSI (4) dsx1AMI (5) other (6)" ::= {prtExVcPbxCnfgEntry 10} prtExVcPbxLineLength OBJECT-TYPE SYNTAX INTEGER { unknown (1), len0p133ft (2), len134p266ft (3), len267p399ft (4), len400p533ft (5), len534p655ft (6), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is the line length parameter. It is applicable only for the VC-PBX/T1 card. notApplicable - for the VC-PBX and VC-PBX/E1 card. lenXXXpXXXft = len-XXX-XXXft." ::= {prtExVcPbxCnfgEntry 11} prtExVcPbxLinkTo OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This object indicates the slot of the ML card to which the VC-PBX/T1, VC-PBX/E1 card Transparent TSs are mapped. notApplicable - for VC-PBX card AND for VC-PBX/T1, VC-PBX/E1 cards, when prtExVcPbxTransparent=no . In the ?004 Unit the entries io6(10)..io12(16) are not valid. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort." ::= {prtExVcPbxCnfgEntry 12} prtExVcPbxSignalOper OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), normal (2), bEqA (3), inverseA (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the Signaling Operation of the VC-PBX/T1, VC-PBX/E1 external port. notApplicable - for VC-PBX card normal - all 4 signaling bits are transferred. bEqA - copy the A bit into the B bit. Applicable only for VC-PBX/T1." ::= {prtExVcPbxCnfgEntry 13} prtExVcPbxIdleCode OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), hff (2), he4 (3), hd5 (4), h9e (5), h98 (6), h7f (7), h7e (8), h54 (9), h1a (10) } MAX-ACCESS read-write STATUS current DESCRIPTION "Determines the code for transmission in empty time slots. notApplicable - for VC-PBX card ." ::= {prtExVcPbxCnfgEntry 14} --prtIn1p6VcPbxCnfgTable defines the parameters of the -- VC-PBX or VF-PBX cards family internal ports 1-6 prtIn1p6VcPbxCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtIn1p6VcPbxCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= { prtVcPbxCnfg 2} prtIn1p6VcPbxCnfgEntry OBJECT-TYPE SYNTAX PrtIn1p6VcPbxCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtIn1p6VcPbxCnfgIdx, prtIn1p6VcPbxSltIdx, prtIn1p6VcPbxPrtIdx } ::= { prtIn1p6VcPbxCnfgTable 1} PrtIn1p6VcPbxCnfgEntry ::= SEQUENCE { prtIn1p6VcPbxCnfgIdx Integer32, prtIn1p6VcPbxSltIdx INTEGER, prtIn1p6VcPbxPrtIdx INTEGER, prtIn1p6VcPbxConnect INTEGER, prtIn1p6VcPbxRate INTEGER, prtIn1p6VcPbxEchoCanceler INTEGER, prtIn1p6VcPbxPabxTs Integer32 } prtIn1p6VcPbxCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg" ::= {prtIn1p6VcPbxCnfgEntry 1} prtIn1p6VcPbxSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid." ::= {prtIn1p6VcPbxCnfgEntry 2} prtIn1p6VcPbxPrtIdx OBJECT-TYPE SYNTAX INTEGER { inPrt1 (101) , inPrt2 (102) , inPrt3 (103) , inPrt4 (104) , inPrt5 (105) , inPrt6 (106) } MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier of the port, within the card." ::= {prtIn1p6VcPbxCnfgEntry 3} prtIn1p6VcPbxConnect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether the port should be considered in any of the mux algorithms." ::= {prtIn1p6VcPbxCnfgEntry 4} prtIn1p6VcPbxRate OBJECT-TYPE SYNTAX INTEGER { r4800bps (1), r6400bps (2), r7200bps (3), r8000bps (4), r9600bps (5), r12800bps (6) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the port Rate. For Normal mode (prtIn7p8VcPbxMode=normal), only part of the values are valid (constant rate). For Server mode (prtIn7p8VcPbxMode=server), all values are applicable (user can select the desired compression rate). " ::= {prtIn1p6VcPbxCnfgEntry 5} prtIn1p6VcPbxEchoCanceler OBJECT-TYPE SYNTAX INTEGER { off (2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Echo canceler activation." ::= {prtIn1p6VcPbxCnfgEntry 6} prtIn1p6VcPbxPabxTs OBJECT-TYPE SYNTAX Integer32 (1..31) MAX-ACCESS read-only STATUS current DESCRIPTION "This object defines the PABX Time-Slot assigned to this internal port. For a T1 link, the valid values are: 1 .. 24. For an E1 link, the valid values are: 1 .. 31. This object is NOT applicable when prtIn1p6VcPbxConnect=no. This object is applicable for all cards of VC-PBX family. Default=the internal port index (1..6)." ::= {prtIn1p6VcPbxCnfgEntry 7} --prtIn7p8VcPbxCnfgTable defines the parameters of the -- VC-PBX or VF-PBX cards family internal ports 7-8 prtIn7p8VcPbxCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtIn7p8VcPbxCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= { prtVcPbxCnfg 3} prtIn7p8VcPbxCnfgEntry OBJECT-TYPE SYNTAX PrtIn7p8VcPbxCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtIn7p8VcPbxCnfgIdx, prtIn7p8VcPbxSltIdx, prtIn7p8VcPbxPrtIdx } ::= { prtIn7p8VcPbxCnfgTable 1} PrtIn7p8VcPbxCnfgEntry ::= SEQUENCE { prtIn7p8VcPbxCnfgIdx Integer32, prtIn7p8VcPbxSltIdx INTEGER, prtIn7p8VcPbxPrtIdx INTEGER, prtIn7p8VcPbxConnect INTEGER, prtIn7p8VcPbxMode INTEGER, prtIn7p8VcPbxRate INTEGER, prtIn7p8VcPbxSignalMode INTEGER, prtIn7p8VcPbxOos INTEGER, prtIn7p8VcPbxLinkTo INTEGER } prtIn7p8VcPbxCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg" ::= {prtIn7p8VcPbxCnfgEntry 1} prtIn7p8VcPbxSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid." ::= {prtIn7p8VcPbxCnfgEntry 2} prtIn7p8VcPbxPrtIdx OBJECT-TYPE SYNTAX INTEGER { inPrt7 (107) , inPrt8 (108) } MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier of the port, within the card." ::= {prtIn7p8VcPbxCnfgEntry 3} prtIn7p8VcPbxConnect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether the port should be considered in any of the mux algorithms." ::= {prtIn7p8VcPbxCnfgEntry 4} prtIn7p8VcPbxMode OBJECT-TYPE SYNTAX INTEGER { normal (1), server (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the working mode of the port: - normal - the compressed voice will be sent to an MTML card inside the Mux. - server - the compressed voice will be sent to the Digital Voice connector, as a service to an outside user." ::= {prtIn7p8VcPbxCnfgEntry 5} prtIn7p8VcPbxRate OBJECT-TYPE SYNTAX INTEGER { r32Kbps (1), r16Kbps (2), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the port Main Rate. For Server mode (prtIn7p8VcPbxMode=server), the value will be notApplicable. " ::= {prtIn7p8VcPbxCnfgEntry 6} prtIn7p8VcPbxSignalMode OBJECT-TYPE SYNTAX INTEGER { none (1), aBit (2), abcBit (3), abcdBit (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the Signal Mode. For Server mode (prtIn7p8VcPbxMode=server), the only valid values are: - none - aBit " ::= {prtIn7p8VcPbxCnfgEntry 7} prtIn7p8VcPbxOos OBJECT-TYPE SYNTAX INTEGER { forcedIdle (1), forcedBusy (2) } MAX-ACCESS read-write STATUS current DESCRIPTION " Out of service Signaling mode." ::= {prtIn7p8VcPbxCnfgEntry 8} prtIn7p8VcPbxLinkTo OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This object indicates the slot of the ML card to which the VC card is mapped. In the ?004 Unit the entries io6(10)..io12(16) are not valid. For Server mode (prtIn7p8VcPbxMode=server), this object is not applicable. Both ports, 7 and 8 should be linked to the same Slot. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort." ::= {prtIn7p8VcPbxCnfgEntry 9} --prtExVcPbxTsTable defines PABX Time Slots assignment of the -- VC-PBX E1/T1 cards prtExVcPbxTsTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtExVcPbxTsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the table objects is valid only to the TmpCnfg entry." ::= { prtVcPbxCnfg 4} prtExVcPbxTsEntry OBJECT-TYPE SYNTAX PrtExVcPbxTsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtExVcPbxTsCnfgIdx, prtExVcPbxTsSltIdx, prtExVcPbxTsPrtIdx, prtExVcPbxTsIdx } ::= { prtExVcPbxTsTable 1} PrtExVcPbxTsEntry ::= SEQUENCE { prtExVcPbxTsCnfgIdx Integer32, prtExVcPbxTsSltIdx INTEGER, prtExVcPbxTsPrtIdx INTEGER, prtExVcPbxTsIdx Integer32, prtExVcPbxTsMode INTEGER, prtExVcPbxTsIConSlot INTEGER, prtExVcPbxTsIConPrt INTEGER } prtExVcPbxTsCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. " ::= { prtExVcPbxTsEntry 1} prtExVcPbxTsSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid" ::= { prtExVcPbxTsEntry 2} prtExVcPbxTsPrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number. VCPBX/E1 and VCPBX/T1 cards have only one external interface." ::= { prtExVcPbxTsEntry 3} prtExVcPbxTsIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique PABX time slot position. The valid time slots are 1..24 for VC-PBX/T1 and 1..31 for VC-PBX/E1." ::= { prtExVcPbxTsEntry 4} prtExVcPbxTsMode OBJECT-TYPE SYNTAX INTEGER { unused (1), compressed (2), transparent (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the usage, process and way of the specific PABX TS towards its destination: unused - the TS is not used (no processing, no destination). compressed - the TS is used, sent for compression to an internal port 1..6 of either the same card or a VC-PBX card of the same group. transparent - the TS is used, no processing, it is sent directly to the ML card the VC-PBX/T1,(E1) is linked to." ::= { prtExVcPbxTsEntry 5} prtExVcPbxTsIConSlot OBJECT-TYPE SYNTAX INTEGER { noConnect (2), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-write STATUS current DESCRIPTION "The object's io1..io12 values are applicable only when prtExVcPbxTsMode=compressed. Otherwise, its value should be noConnect. This object indicates whether the specified compressed time slot is connected/routed internally in the Agent and to which card it is connected. The valid selectable slots are either the current one, (prtExVcPbxTsSltIdx), or a slot containing a VC-PBX card. In the ?004 Unit the entries io6(10)..io12(16) are not valid." ::= {prtExVcPbxTsEntry 6} prtExVcPbxTsIConPrt OBJECT-TYPE SYNTAX INTEGER { noConnect (100), inPrt1 (101) , inPrt2 (102) , inPrt3 (103) , inPrt4 (104) , inPrt5 (105) , inPrt6 (106) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the internal VC-PBX port to which this PABX TS is connected for compression. noConnect - when prtExVcPbxTsIConSlot=noConnect." ::= {prtExVcPbxTsEntry 7} -- The following tables contains information specific to -- the isdn access modules prtIsdnCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtIsdnCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the table objects is valid only to the TmpCnfg entry." ::= { prtIsdnCnfg 1} prtIsdnCnfgEntry OBJECT-TYPE SYNTAX PrtIsdnCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtIsdnCnfgIdx, prtIsdnSltIdx, prtIsdnPrtIdx} ::= { prtIsdnCnfgTable 1} PrtIsdnCnfgEntry ::= SEQUENCE { prtIsdnCnfgIdx Integer32, prtIsdnSltIdx INTEGER, prtIsdnPrtIdx Integer32, prtIsdnConnect INTEGER, prtIsdnSignalingProtocol INTEGER, prtIsdnBasicRateLineTopology INTEGER, prtIsdnMode INTEGER, prtIsdnFilter INTEGER, prtIsdnSimultaneousCall INTEGER, prtIsdnNumOfAbstractTerm Integer32, prtIsdnSwitchMode INTEGER, prtIsdnAbSide INTEGER, prtIsdnQsigRole INTEGER, prtIsdnInterface INTEGER, prtIsdnCallMode INTEGER, prtIsdnCallBackTimeout INTEGER } prtIsdnCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. " ::= { prtIsdnCnfgEntry 1} prtIsdnSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10(14), io11(15), io12(16), kmxMlA (103), kmxMlB (104), notApplicable(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid For KM2100/4 Valid entries are 'kmxMlA ' or 'kmxMlB'" ::= { prtIsdnCnfgEntry 2} prtIsdnPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number. For MAXcess the values will be: exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), For KM-2100 the port index is calculated as follows: 100*Slot+Ch" ::= { prtIsdnCnfgEntry 3} prtIsdnConnect OBJECT-TYPE SYNTAX INTEGER { no(2), yes(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates if the port is connected." ::= { prtIsdnCnfgEntry 4 } prtIsdnSignalingProtocol OBJECT-TYPE SYNTAX INTEGER { other(1), etsi(3), ess5(6), dms100(7), ni1(9), ni2(10), ins64(17), ins1500(18), qsig(21), notApplicable(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute fixes which signaling protocol is used at this port (D-Channel). It is equivalent to isdnSignalingProtocol in the isdn MIB." DEFVAL { etsi } ::= { prtIsdnCnfgEntry 5 } prtIsdnBasicRateLineTopology OBJECT-TYPE SYNTAX INTEGER { pointToPoint(1), pointToMultipoint(2), notApplicable(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute is relevant for ISDN BRI only. It is equivalent to isdnBasicRateLineTopology in the isdn MIB." ::= { prtIsdnCnfgEntry 6 } prtIsdnMode OBJECT-TYPE SYNTAX INTEGER { dialup(1), leased(2), syncLeased(3), notApplicable(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute allows the user to configure the port as leased(2) in case of connection to a TDM network." ::= { prtIsdnCnfgEntry 7} prtIsdnFilter OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), answerAll(2), rejectAll(3), selective(4), callBack (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute allows the user to configure the port: answerAll(2): accept all incoming calls, rejectAll(3): reject all incoming calls, selective(4): accept or reject according directory table. callBack (5): In this mode the ISDN Ch will reject incoming calls and will initiate call back to the rejected phone number." ::= { prtIsdnCnfgEntry 8} prtIsdnSimultaneousCall OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), accept(2), reject(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "In case of simultaneous call (local,remote and remote,local): accept(2): accept the incoming call, reject(3): reject the incoming call." ::= { prtIsdnCnfgEntry 9} prtIsdnNumOfAbstractTerm OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "An object for KM2100/4 agents. 255=Not Applicable When ISDN Standard = ETSI or NTT (European) the value should be 255 (NotApplicable) else If ML speed is 64Kbps value should be 1. If ML speed is 128Kbps value can be either 1 or 2 (user selection)." ::= { prtIsdnCnfgEntry 10} prtIsdnSwitchMode OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), auto (2), manual (3), connect(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "For KM2100. auto - The call is initiated automatically by one of the IO cards connected to KML.10(ISDN card) having ISDN Switch Mode. manual - The call is initiated by the user manually, for KML.10 having ISDN Switch Mode (via mdlSCmd). connect- The call is initiated 'immediately', for KML.10 having ISDN Switch Mode. 'immediately'- means: immediately after power-up (when product performed Reset) OR, since this value appears in the active configuration. In this case, the call can be disconnected only by power-off of the product or by changing this object to another value (or actual Remove of the KML.10 relevant card). notApplicable - For other card types." ::= { prtIsdnCnfgEntry 11} prtIsdnAbSide OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), aSide (2), bSide (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter indicates the QSIG side in layer 3. This definition is from the QSIG Standard." ::= { prtIsdnCnfgEntry 12} prtIsdnQsigRole OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), slave (2), master (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter indicates the QSIG side in layer 1 & 2." ::= { prtIsdnCnfgEntry 13} prtIsdnInterface OBJECT-TYPE SYNTAX INTEGER { lt (1), nt (2), te (3), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "It indicates the interface type: lt = line termination nt = network termination te = terminal equipment." ::= { prtIsdnCnfgEntry 14} prtIsdnCallMode OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), initiate (2), listen (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the acceptance of incoming calls. Initiate - Callout Listen - Callin. " ::= { prtIsdnCnfgEntry 15} prtIsdnCallBackTimeout OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "This object is applicable only if 'prtIsdnFilter' is 'CallBack' and determines how long to wait from receiving the incoming call until initiating the call back call. The vaules range should be '1..20 sec' and the default 10 sec." ::= { prtIsdnCnfgEntry 16} prtIsdnEndpointTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtIsdnEndpointEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the table objects is valid only to the TmpCnfg entry." ::= { prtIsdnCnfg 2} prtIsdnEndpointEntry OBJECT-TYPE SYNTAX PrtIsdnEndpointEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtIsdnEndpointCnfgIdx, prtIsdnEndpointSltIdx, prtIsdnEndpointPrtIdx, prtIsdnEndpointIdx } ::= { prtIsdnEndpointTable 1} PrtIsdnEndpointEntry ::= SEQUENCE { prtIsdnEndpointCnfgIdx Integer32, prtIsdnEndpointSltIdx INTEGER, prtIsdnEndpointPrtIdx Integer32, prtIsdnEndpointIdx INTEGER, prtIsdnEndpointTeiType INTEGER, prtIsdnEndpointTeiValue Integer32, prtIsdnEndpointSpid DisplayString, prtIsdnEndpointBearerCh INTEGER, prtIsdnEndpointRowStatus RowStatus } prtIsdnEndpointCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. " ::= { prtIsdnEndpointEntry 1} prtIsdnEndpointSltIdx OBJECT-TYPE SYNTAX INTEGER { io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), kmxMlA (103), kmxMlB (104), notApplicable(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In ?004 Unit the entries io6(10)..io12(16) are not valid For KM2100/4 Valid entries are 'kmxMlA ' or 'kmxMlB'" ::= { prtIsdnEndpointEntry 2} prtIsdnEndpointPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number. For MAXcess the values will be: exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), For KM-2100 the port index is calculated as follows: 100*Slot+Ch" ::= { prtIsdnEndpointEntry 3} prtIsdnEndpointIdx OBJECT-TYPE SYNTAX INTEGER { atei1(1), atei2(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Since more than one endpoint may be defined per isdn entity, this field is a simple index. It corresponds to isdnEndpointIdx in the isdn MIB." DEFVAL { atei1 } ::= { prtIsdnEndpointEntry 4} prtIsdnEndpointTeiType OBJECT-TYPE SYNTAX INTEGER { dynamic(1), static(2), notApplicable(255) } MAX-ACCESS read-create STATUS current DESCRIPTION "The type of TEI (Terminal Endpoint Identifier) used for this Terminal Endpoint. In case of dynamic(1), the TEI value is selected by the switch. In case of static(2), a valid TEI value has to be entered in the isdnEndpointTeiValue object. interface type as well as the Terminal Endpoint type. static(2). On Basic Rate interfaces the default value is dynamic(1) for isdn(63) Terminal Endpoints. It corresponds to isdnEndpointTeiType in the isdn MIB." ::= { prtIsdnEndpointEntry 5} prtIsdnEndpointTeiValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "When the TEI Type is static, the value of the TEI should be between 0 and 63. Else, it is not selectable by user. 255 = notApplicable. It corresponds to isdnEndpointTeiValue in the isdn MIB" ::= { prtIsdnEndpointEntry 6 } prtIsdnEndpointSpid OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "The Service profile IDentifier (SPID) information for this Terminal Endpoint. It is is composed of 9-20 numeric characters. It corresponds to isdnEndpointSpid in the isdn MIB." ::= { prtIsdnEndpointEntry 7 } prtIsdnEndpointBearerCh OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), anyChannel (2), channelB1 (3), channelB2 (4) } MAX-ACCESS read-create STATUS current DESCRIPTION "This is the selected dialing channel. anyChannel - the system selects the dialing channel." ::= { prtIsdnEndpointEntry 8} prtIsdnEndpointRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This field indicates whether to consider this endpoint or not. The only possible supported RowStatus vaules are active (1) and destroy (6)." ::= { prtIsdnEndpointEntry 9} prtIsdnDirectoryTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtIsdnDirectoryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the table objects is valid only to the TmpCnfg entry." ::= { prtIsdnCnfg 3} prtIsdnDirectoryEntry OBJECT-TYPE SYNTAX PrtIsdnDirectoryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { prtIsdnDirectoryCnfgIdx, prtIsdnDirectorySltIdx, prtIsdnDirectoryPrtIdx } ::= { prtIsdnDirectoryTable 1} PrtIsdnDirectoryEntry ::= SEQUENCE { prtIsdnDirectoryCnfgIdx Integer32, prtIsdnDirectorySltIdx INTEGER, prtIsdnDirectoryPrtIdx Integer32, prtIsdnDirectoryLocalAddr DisplayString, prtIsdnDirectoryLocalSubAddr DisplayString, prtIsdnDirectoryRemoteAddr DisplayString, prtIsdnDirectoryRemoteSubAddr DisplayString, prtIsdnDirectoryPrtNu Integer32, prtIsdnDirectoryTeiId Integer32, prtIsdnDirectoryRowStatus RowStatus, prtIsdnDirectoryLocalAddr2 DisplayString, prtIsdnDirectoryLocalSubAddr2 DisplayString, prtIsdnDirectoryRemoteAddr2 DisplayString, prtIsdnDirectoryRemoteSubAddr2 DisplayString } prtIsdnDirectoryCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. " ::= { prtIsdnDirectoryEntry 1} prtIsdnDirectorySltIdx OBJECT-TYPE SYNTAX INTEGER { io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), kmxMlA (103), kmxMlB (104), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. For MX300/30 ports: io1(5) = isdn1(5) and io2(6) = isdn2(6). In ?004 Unit the entries io6(10)..io12(16) are not valid For KM2100/4 Valid entries are 'kmxMlA ' or 'kmxMlB'" ::= { prtIsdnDirectoryEntry 2} prtIsdnDirectoryPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "For MAXcess this is the internal port number: 101, 102,.... For KM-2100 the port index is calculated as follows: 100*Slot+Ch" ::= { prtIsdnDirectoryEntry 3} prtIsdnDirectoryLocalAddr OBJECT-TYPE SYNTAX DisplayString (SIZE(17..20)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is the local address associated with this entry. - For MX: Size=17 , Default=0 (17 characters) - For KM: Size=20, Default=blank (20 characters) " ::= { prtIsdnDirectoryEntry 4} prtIsdnDirectoryLocalSubAddr OBJECT-TYPE SYNTAX DisplayString (SIZE(4..6)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is the local subaddress associated with this entry. - For MX: Size=6 , Default=0 (6 characters) - For KM: Size=4 , Default=blank (4 characters)" ::= { prtIsdnDirectoryEntry 5} prtIsdnDirectoryRemoteAddr OBJECT-TYPE SYNTAX DisplayString (SIZE(17..20)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is the remote address associated with this entry. - For MX: Size=17 , Default=0 (17 characters) - For KM: Size=20, Default=blank (20 characters)" ::= { prtIsdnDirectoryEntry 6} prtIsdnDirectoryRemoteSubAddr OBJECT-TYPE SYNTAX DisplayString (SIZE(4..6)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is the remote subaddress associated with this entry. - For MX: Size=6 , Default=0 (6 characters) - For KM: Size=4 , Default=blank (4 characters)" ::= { prtIsdnDirectoryEntry 7} prtIsdnDirectoryPrtNu OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "This is the external port number connected to this entry." DEFVAL { 1 } ::= { prtIsdnDirectoryEntry 8} prtIsdnDirectoryTeiId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "This is the abstract terminal id if relevant, connected to this entry." DEFVAL { 1 } ::= { prtIsdnDirectoryEntry 9} prtIsdnDirectoryRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This is the status for the row. It allows to know whether to consider this row or not. The only possible supported RowStatus vaules are active (1) and destroy (6)." ::= { prtIsdnDirectoryEntry 10} prtIsdnDirectoryLocalAddr2 OBJECT-TYPE SYNTAX DisplayString (SIZE(17..20)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is the second local address associated with this entry. - For MX: Size=17 , Default=0 (17 characters) - For KM: Size=20, Default=blank (20 characters)" ::= { prtIsdnDirectoryEntry 11} prtIsdnDirectoryLocalSubAddr2 OBJECT-TYPE SYNTAX DisplayString (SIZE(4..6)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is the second local subaddress associated with this entry. - For MX: Size=6 , Default=0 (6 characters) - For KM: Size=4 , Default=blank (4 characters)" ::= { prtIsdnDirectoryEntry 12} prtIsdnDirectoryRemoteAddr2 OBJECT-TYPE SYNTAX DisplayString (SIZE(17..20)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is the second remote address associated with this entry. - For MX: Size=17 , Default=0 (17 characters) - For KM: Size=20, Default=blank(20 characters) " ::= { prtIsdnDirectoryEntry 13} prtIsdnDirectoryRemoteSubAddr2 OBJECT-TYPE SYNTAX DisplayString (SIZE(4..6)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is the second remote subaddress associated with this entry. - For MX: Size=6 , Default=0 (6 characters) - For KM: Size=4 , Default=blank (4 characters) " ::= { prtIsdnDirectoryEntry 14} -- This table is an extension for new version of MAXcess -- modules. prtFrPlusCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtFrPlusCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= {prtFrPlusCnfg 1} prtFrPlusCnfgEntry OBJECT-TYPE SYNTAX PrtFrPlusCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtFrPlusCnfgIdx, prtFrPlusSltIdx, prtFrPlusPrtIdx } ::= { prtFrPlusCnfgTable 1} PrtFrPlusCnfgEntry ::= SEQUENCE { prtFrPlusCnfgIdx Integer32, prtFrPlusSltIdx INTEGER, prtFrPlusPrtIdx Integer32, prtFrPlusNotSegmentedPriorities OCTET STRING } prtFrPlusCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. " ::= { prtFrPlusCnfgEntry 1} prtFrPlusSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Slot Index. For ISDN BRI Ports of MX300/30, io1(5) = isdn1(5) and io2(6) = isdn2(6)." ::= { prtFrPlusCnfgEntry 2} prtFrPlusPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number. This port number should be: - for ISDN cards: inPrt1(101)->inPrt50(150) - for MHS1 card : exPrt1(1) - for MHS3, MLS3 cards: exPrt1(1)->exPrt3(3) - for MLS6 cards: exPrt1(1)->exPrt6(6)." ::= { prtFrPlusCnfgEntry 3} prtFrPlusNotSegmentedPriorities OBJECT-TYPE SYNTAX OCTET STRING(SIZE(1)) MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter is relevant only for FR+ protocol and asks the MXcess NOT to segment data with specified priorities: from LSB: bit 1 is for priority 1, bit 2 is for priority 2, .... till bit 7 for priority 7. - a priority selected to be segmented : its bit will be '0' - a priority not to be segmented : its bit will be '1' Default is 00000000; i.e, segment all priorities." DEFVAL { '00'H } ::= { prtFrPlusCnfgEntry 4 } -- This table is an extension of prtExPh1MlCnfgTable for MTML-4 cards -- of MP-2200 prtMl4CnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtMl4CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is an extension table for MTML-4 card parameters." ::= {prtMl4Cnfg 1} prtMl4CnfgEntry OBJECT-TYPE SYNTAX PrtMl4CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtMl4CnfgIdx, prtMl4SltIdx, prtMl4PrtIdx } ::= { prtMl4CnfgTable 1} PrtMl4CnfgEntry ::= SEQUENCE { prtMl4CnfgIdx Integer32, prtMl4SltIdx INTEGER, prtMl4PrtIdx INTEGER, prtMl4SigProfile INTEGER, prtMl4CGA INTEGER, prtMl4Oos INTEGER, prtMl4VoiceOos OCTET STRING, prtMl4DataOos OCTET STRING, prtMl4Service INTEGER, prtMl4IpAddress IpAddress, prtMl4IpMask IpAddress, prtMl4SignalingMode INTEGER, prtMl4EchoCanceler INTEGER, prtMl4OosErrorSource INTEGER, prtMl4OosEntryThreshold Integer32, prtMl4OosExitThreshold Integer32 } prtMl4CnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. The write operation is valid only to the TmpCnfg." ::= { prtMl4CnfgEntry 1} prtMl4SltIdx OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the module is inserted." ::= { prtMl4CnfgEntry 2} prtMl4PrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1), exPrt2 (2), exPrt3 (3), exPrt4 (4), inPrt1 (101), inPrt2 (102), inPrt3 (103), inPrt4 (104) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number." ::= { prtMl4CnfgEntry 3} prtMl4SigProfile OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), none (2), p1 (3), p2 (4), p3 (5), p4 (6), p5 (7) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the Signaling Profile of the port. none - when the Frame is G732N (no MF). p1 = profile 1 p2 = profile 2 p3 = profile 3 p4 = profile 4 p5 = profile 5 " ::= {prtMl4CnfgEntry 4} prtMl4CGA OBJECT-TYPE SYNTAX INTEGER { none (1), trans(2), full (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object selects the method used to signal the CGA state to the other end, through the main link. 'none' - non-transparent mode. When one of the links (main) will be in Out Of Service state, both 'Data/Voice Oos' and 'Oos' will be transmitted to the other end. 'trans' - when one of the links (main) will be in Out Of Service state, 'Data/Voice Oos' will be transmitted to the other end. 'full' - fully-transparent mode. When one of the links (main) will be in Out Of Service state, neither 'Data/Voice Oos' nor 'Oos' will be transmitted to the other end." ::= { prtMl4CnfgEntry 5 } prtMl4Oos OBJECT-TYPE SYNTAX INTEGER { notSupported (2), forcedIdle (3), forcedBusy (4), busyIdle (5), idleBusy (6) } MAX-ACCESS read-write STATUS current DESCRIPTION "'idle' = '0' = on-hook, idle state 'busy' = '1' = off-hook, busy state 'forcedIdle' = SP = both A and B signaling bits are forced to '0' during out-of-service periods. 'forcedBusy' = MK = both A and B signaling bits are forced to '1' during out-of-service periods. 'busyIdle' = MK_SP = A and B bits are forced to '1' for 2.5 seconds; then they are switched to '0' until out-of-service condition disappears. 'idleBusy' = SP_MK = A and B bits are forced to '0' for 2.5 seconds; then they are switched to '1' until out-of-service condition disappears. - for T1: '0'=0 ; '1'=1 - for E1: '0'=1 ; '1'=0 " ::= { prtMl4CnfgEntry 6 } prtMl4VoiceOos OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..4)) MAX-ACCESS read-write STATUS current DESCRIPTION "Voice Out-Of-Service code. Valid range: (0 - FF HEX). For agents that do not support this feature, the value will always be 0." ::= { prtMl4CnfgEntry 7 } prtMl4DataOos OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..4)) MAX-ACCESS read-write STATUS current DESCRIPTION "Data Out-Of-Service code. Valid range: (0 - FF HEX). For agents that do not support this feature, the value will always be 0." ::= { prtMl4CnfgEntry 8 } prtMl4Service OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), leasedLine (2), v51 (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Link Service. leasedLine - usual TDM interface. v51 - V5.1 interface. " ::= {prtMl4CnfgEntry 9} prtMl4IpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "IP Address of the port." ::= {prtMl4CnfgEntry 10} prtMl4IpMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "IP subnet mask of the port." ::= {prtMl4CnfgEntry 11} prtMl4SignalingMode OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), cas(2), ccs(3), robbedBit(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Refers to the signaling mode of the Framer module. cas(2) means Channel Associated Signaling. Used for E1 Links. ccs(3) is the Common Channel Signaling (the signaling is not within the channels time slot - a TS for signaling is used). robbedBit(4) is a method implementing 7 bits for the voice and 1 bit dedicated for signaling. Used for T1 Links." ::= {prtMl4CnfgEntry 12} prtMl4EchoCanceler OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), off (2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Echo canceler activation." ::= {prtMl4CnfgEntry 13} prtMl4OosErrorSource OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), none (2), framing (3), bpv (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "OOS (Out-of-Service) Error Source. This object is applicable for T1 ports only." ::= {prtMl4CnfgEntry 14} prtMl4OosEntryThreshold OBJECT-TYPE SYNTAX Integer32 (0..999) MAX-ACCESS read-write STATUS current DESCRIPTION "This object defines the number of Errors per Second that determine the minimum unacceptable noise level. This value will be the Entry Threshold to the OOS (Out-of-Service) state. This object is applicable only when prtMl4OosErrorSource=framing(3) or bpv(4). 0=notApplicable." ::= { prtMl4CnfgEntry 15} prtMl4OosExitThreshold OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-write STATUS current DESCRIPTION "This object defines the number of consecutive Error-Free-Seconds before going from OOS state to Normal state. This value will be the Exit Threshold from the OOS (Out-of-Service) state. Units=seconds This object is applicable only when prtMl4OosErrorSource=framing(3) or bpv(4). 0=notApplicable." ::= { prtMl4CnfgEntry 16} --prtAcmCnfgTable defines the parameters of the --ACM cards family external ports 1-8 prtAcmCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtAcmCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a table for ACM port parameters." ::= {prtAcmCnfg 1} prtAcmCnfgEntry OBJECT-TYPE SYNTAX PrtAcmCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtAcmCnfgIdx, prtAcmSltIdx, prtAcmPrtIdx } ::= { prtAcmCnfgTable 1} PrtAcmCnfgEntry ::= SEQUENCE { prtAcmCnfgIdx Integer32, prtAcmSltIdx INTEGER, prtAcmPrtIdx INTEGER, prtAcmConnect INTEGER, prtAcmActiveState INTEGER, prtAcmAlrString DisplayString } prtAcmCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. The write operation is valid only to the TmpCnfg." ::= { prtAcmCnfgEntry 1} prtAcmSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the module is inserted." ::= { prtAcmCnfgEntry 2} prtAcmPrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1), exPrt2 (2), exPrt3 (3), exPrt4 (4), exPrt5 (5), exPrt6 (6), exPrt7 (7), exPrt8 (8) , exPrt9 (9) , exPrt10 (10) , exPrt11 (11) , exPrt12 (12) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number." ::= { prtAcmCnfgEntry 3} prtAcmConnect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port should be connected or not. Only a connected port can perform activity." ::= {prtAcmCnfgEntry 4} prtAcmActiveState OBJECT-TYPE SYNTAX INTEGER { low (2), high (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the Electric Active State of the port." ::= {prtAcmCnfgEntry 5} prtAcmAlrString OBJECT-TYPE SYNTAX DisplayString (SIZE(0..35)) MAX-ACCESS read-write STATUS current DESCRIPTION "Alarm string selected by user for the Inbound ports. This object is applicable only for the Inbound Ports: ext-5..ext-12. For the Outbound Ports (ext-1..ext-4), the size of this string will be 0." ::= {prtAcmCnfgEntry 6} --prtE2CnfgTable defines the parameters of the --E2 card ports prtE2CnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtE2CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a table for E2 port parameters." ::= {prtE2Cnfg 1} prtE2CnfgEntry OBJECT-TYPE SYNTAX PrtE2CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtE2CnfgIdx, prtE2SltIdx, prtE2PrtIdx } ::= { prtE2CnfgTable 1} PrtE2CnfgEntry ::= SEQUENCE { prtE2CnfgIdx Integer32, prtE2SltIdx INTEGER, prtE2PrtIdx INTEGER, prtE2Connect INTEGER, prtE2MngOnNationalBit INTEGER } prtE2CnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. The write operation is valid only to the TmpCnfg." ::= { prtE2CnfgEntry 1} prtE2SltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the module is inserted." ::= { prtE2CnfgEntry 2} prtE2PrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1), exPrt2 (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number." ::= { prtE2CnfgEntry 3} prtE2Connect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port should be connected or not. Only a connected port can perform activity." ::= {prtE2CnfgEntry 4} prtE2MngOnNationalBit OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether National Bit will be used for Management or not." ::= {prtE2CnfgEntry 5} -- -- The following table includes the IP addresses of all the NMS to which -- Traps will be sent -- --mngTrapIpTable OBJECT-TYPE -- SYNTAX SEQUENCE OF MngTrapIpEntry -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- "This table indicates the destination address of the traps. -- Internally it will be limited to ten addresses. " -- ::= { agnt 7 } -- --mngTrapIpEntry OBJECT-TYPE -- SYNTAX MngTrapIpEntry -- MAX-ACCESS not-accessible -- STATUS current -- INDEX { mngTrapIpIdx } -- ::= { mngTrapIpTable 1 } -- --MngTrapIpEntry ::= -- SEQUENCE { -- mngTrapIpIdx Integer32, -- mngTrapIpIP IpAddress, -- mngTrapIpIPMask IpAddress -- } -- --mngTrapIpIdx OBJECT-TYPE -- SYNTAX Integer32 -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- " This value indicates an index of a specific IP address" -- ::= { mngTrapIpEntry 1 } -- --mngTrapIpIP OBJECT-TYPE -- SYNTAX IpAddress -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "This value indicates the destination addresses of the traps. " -- ::= { mngTrapIpEntry 2 } -- --mngTrapIpIPMask OBJECT-TYPE -- SYNTAX IpAddress -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "This value indicates the mask of the destination addresses of the traps. " -- ::= { mngTrapIpEntry 3 } -- -- -- Traps --NOTIFICATIONS muxHubEvents OBJECT-IDENTITY STATUS current DESCRIPTION "The events for ." ::= { muxHub 0 } alarmsTrap NOTIFICATION-TYPE OBJECTS { alrBufDescription } STATUS current DESCRIPTION "This trap is sent whenever alarm occurs in the agent." ::= { muxHubEvents 1 } sanityTrap NOTIFICATION-TYPE OBJECTS { agnSSanityCheckStatus, agnCSaveCnfgIdxCmd } STATUS current DESCRIPTION "This trap is sent after a data base update. It returns the sanity result status and the configuration no. checked. If the result is of Flip DB Sanity Check, the configuration no. sent will be 0. If the result is of Variant Sanity Check, the configuration no. sent will be 100." ::= { muxHubEvents 2 } cnfgFlipTrap NOTIFICATION-TYPE OBJECTS { agnSActiveCnfg } STATUS current DESCRIPTION "This trap is sent upon change of the active Configuration DB. Attached, is the new active Configuration no." ::= { muxHubEvents 3 } flipDbChangeTrap NOTIFICATION-TYPE STATUS current DESCRIPTION "This trap is sent upon change of the active Flip tables (Flip DB)." ::= { muxHubEvents 4 } statusChangedTrap NOTIFICATION-TYPE OBJECTS { agnLed } STATUS current DESCRIPTION "This trap is sent upon any change of the LEDs status." ::= { muxHubEvents 5 } -- -- file :v:\doc\rdv\mib\ver485\ethIf.txt -- --01/08/2000 --By: Smadar Tauber --File: s:\doc\rdv\mib\ver485\ethIf.txt --EthIf MIB - separated from mpmx.txt --diverseIfWanGen OBJECT IDENTIFIER ::= {wanGen 6} --Last update: 20-Jan-2002 by Ilana Schvetz -- -- diverseIf - diverse NON-WAN interfaces of WAN products -- --Ethernet Interface ethIf OBJECT IDENTIFIER ::= {diverseIfWanGen 1} --Ethernet Interface ethIfTable OBJECT-TYPE SYNTAX SEQUENCE OF EthIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= { ethIf 1} ethIfEntry OBJECT-TYPE SYNTAX EthIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {ethIfIdx} ::= {ethIfTable 1} EthIfEntry ::= SEQUENCE { ethIfIdx Integer32, ethMode INTEGER, ethBridgingMode INTEGER, ethEncapsulationCRCMode INTEGER, ethBackPressure INTEGER, ethLimit4 INTEGER, ethSkipInitReset INTEGER, ethMulticastBlock INTEGER, ethBroadcastBlock INTEGER, ethSpeed INTEGER } ethIfIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique index of the ethernet interface/port." ::= {ethIfEntry 1} ethMode OBJECT-TYPE SYNTAX INTEGER { halfDuplex (1), fullDuplex (2), notApplicable(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the Ethernet mode of operation." ::= {ethIfEntry 2} ethBridgingMode OBJECT-TYPE SYNTAX INTEGER { filtered (1), transparent (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the bridging mode of the Ethernet interface. " ::= {ethIfEntry 3} ethEncapsulationCRCMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), withCRC (2), withoutCRC (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object define the encapsulation type requested for the Ethernet interface. It indicates if we transfer the Ethernet frame to the other side with or without the CRC. " ::= {ethIfEntry 4} ethBackPressure OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter defines whether to enable or disable Back pressure. Back Pressure is a flow control parameter. " ::= {ethIfEntry 5} ethLimit4 OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter determine the Back off algorithm mode. Every 4 following collisions the Framer will be thrown out (4 times more than usuall)." ::= {ethIfEntry 6} ethSkipInitReset OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), notSkip (2), skip (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter defines whether read status on reset. " ::= {ethIfEntry 7} ethMulticastBlock OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), unBlock (2), block (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter defines whether to send multicast message to WAN from LAN or not. " ::= {ethIfEntry 8} ethBroadcastBlock OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), unBlock (2), block (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter defines whether to send broadcast message to WAN from LAN or not." ::= {ethIfEntry 9} ethSpeed OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), s10Mbps (2), s100Mbps (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter defines the line speed." ::= {ethIfEntry 10} ethIfPerformance OBJECT IDENTIFIER ::= {ethIf 2} ethIfCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF EthIfCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Ethernet Current table." ::= { ethIfPerformance 1} ethIfCurrentEntry OBJECT-TYPE SYNTAX EthIfCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Ethernet Current table." INDEX {ethIfCurrentIndex} ::= {ethIfCurrentTable 1} EthIfCurrentEntry ::= SEQUENCE { ethIfCurrentIndex Integer32, ethIfCurrentStatus OCTET STRING, ethIfCurrentInFrames Gauge32, ethIfCurrentInOctets Gauge32, ethIfCurrentAlignmentErrors Gauge32, ethIfCurrentFCSErrors Gauge32, ethIfCurrentLengthError Gauge32, ethIfCurrentOutFrames Gauge32, ethIfCurrentOutOctets Gauge32, ethIfCurrentSingleCollisionFrames Gauge32, ethIfCurrentMultipleCollisionFrames Gauge32, ethIfCurrentDeferredTransmissions Gauge32, ethIfCurrentLateCollisions Gauge32, ethIfCurrentCarrierSenseErrors Gauge32 } ethIfCurrentIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Ethernet interface. It may be ifIndex." ::= { ethIfCurrentEntry 1 } ethIfCurrentStatus OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) MAX-ACCESS read-only STATUS current DESCRIPTION "The statuses of the current interval: 0 - Valid. 1 - redundantLinkSwitch - the link has been switched by a redundancy mechanism. 2 - discontinuity - module was partialy out. 4 - notValid - module is out." ::= { ethIfCurrentEntry 2 } ethIfCurrentInFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received frames, encountered by the Ethernet interface in the current 15 minute interval." ::= { ethIfCurrentEntry 3 } ethIfCurrentInOctets OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received octets, encountered by the Ethernet interface in the current 15 minute interval." ::= { ethIfCurrentEntry 4 } ethIfCurrentAlignmentErrors OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received frames, which are not complete (The result of dividing the number of bits by 8 is not an Integer), encountered by the Ethernet interface in the current 15 minute interval." ::= { ethIfCurrentEntry 5 } ethIfCurrentFCSErrors OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received frames that didn't pass the FCS test, encountered by the Ethernet interface in the current 15 minute interval." ::= { ethIfCurrentEntry 6 } ethIfCurrentLengthError OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received frames with length error, encountered by the Ethernet interface in the current 15 minute interval." ::= { ethIfCurrentEntry 7 } ethIfCurrentOutFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted frames, encountered by the Ethernet interface in the current 15 minute interval." ::= { ethIfCurrentEntry 8 } ethIfCurrentOutOctets OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted octets, encountered by the Ethernet interface in the current 15 minute interval." ::= { ethIfCurrentEntry 9 } ethIfCurrentSingleCollisionFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of successfully transmitted frames for which transmission was inhibited by exactly one collision, encountered by the Ethernet interface in the current 15 minute interval." ::= { ethIfCurrentEntry 10 } ethIfCurrentMultipleCollisionFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of successfully transmitted frames for which transmission was inhibited by more than one collision, encountered by the Ethernet interface in the current 15 minute interval." ::= { ethIfCurrentEntry 11 } ethIfCurrentDeferredTransmissions OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted frames for which the first transmission attempt was delayed due to a busy media, encountered by the Ethernet interface in the current 15 minute interval." ::= { ethIfCurrentEntry 12 } ethIfCurrentLateCollisions OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of times that a collision was detected later than the first 64 bytes of the frame, encountered by the Ethernet interface in the current 15 minute interval." ::= { ethIfCurrentEntry 13 } ethIfCurrentCarrierSenseErrors OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of times that the carrier sense condition was lost or never asserted when attempting to transmit a frame, encountered by the Ethernet interface in the current 15 minute interval." ::= { ethIfCurrentEntry 14 } --Interval Table ethIfIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF EthIfIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Ethernet Interval table." ::= { ethIfPerformance 2 } ethIfIntervalEntry OBJECT-TYPE SYNTAX EthIfIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Ethernet Interval table." INDEX { ethIfIntervalIndex, ethIfIntervalNumber } ::= {ethIfIntervalTable 1} EthIfIntervalEntry ::= SEQUENCE { ethIfIntervalIndex Integer32, ethIfIntervalNumber Integer32, ethIfIntervalStatus OCTET STRING, ethIfIntervalInFrames Gauge32, ethIfIntervalInOctets Gauge32, ethIfIntervalAlignmentErrors Gauge32, ethIfIntervalFCSErrors Gauge32, ethIfIntervalLengthError Gauge32, ethIfIntervalOutFrames Gauge32, ethIfIntervalOutOctets Gauge32, ethIfIntervalSingleCollisionFrames Gauge32, ethIfIntervalMultipleCollisionFrames Gauge32, ethIfIntervalDeferredTransmissions Gauge32, ethIfIntervalLateCollisions Gauge32, ethIfIntervalCarrierSenseErrors Gauge32 } ethIfIntervalIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Ethernet interface. It may be ifIndex." ::= { ethIfIntervalEntry 1 } ethIfIntervalNumber OBJECT-TYPE SYNTAX Integer32 (1..96) MAX-ACCESS read-only STATUS current DESCRIPTION "A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals exist)." ::= { ethIfIntervalEntry 2 } ethIfIntervalStatus OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) MAX-ACCESS read-only STATUS current DESCRIPTION "The statuses of the current interval: 0 - Valid. 1 - redundantLinkSwitch - the link has been switched by a redundancy mechanism. 2 - discontinuity - module was partialy out. 4 - notValid - module is out." ::= { ethIfIntervalEntry 3 } ethIfIntervalInFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received frames, encountered by the Ethernet interface in one of the previous 96, individual 15 minute, intervals." ::= { ethIfIntervalEntry 4 } ethIfIntervalInOctets OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received octets, encountered by the Ethernet interface in one of the previous 96, individual 15 minute, intervals." ::= { ethIfIntervalEntry 5 } ethIfIntervalAlignmentErrors OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received frames, which are not complete (The result of dividing the number of bits by 8 is not an Integer), encountered by the Ethernet interface in one of the previous 96, individual 15 minute, intervals." ::= { ethIfIntervalEntry 6 } ethIfIntervalFCSErrors OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received frames that didn't pass the FCS test, encountered by the Ethernet interface in one of the previous 96, individual 15 minute, intervals." ::= { ethIfIntervalEntry 7 } ethIfIntervalLengthError OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received frames with length error, encountered by the Ethernet interface in one of the previous 96, individual 15 minute, intervals." ::= { ethIfIntervalEntry 8 } ethIfIntervalOutFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted frames, encountered by the Ethernet interface in one of the previous 96, individual 15 minute, intervals." ::= { ethIfIntervalEntry 9 } ethIfIntervalOutOctets OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted octets, encountered by the Ethernet interface in one of the previous 96, individual 15 minute, intervals." ::= { ethIfIntervalEntry 10 } ethIfIntervalSingleCollisionFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of successfully transmitted frames for which transmission was inhibited by exactly one collision, encountered by the Ethernet interface in one of the previous 96, individual 15 minute, intervals." ::= { ethIfIntervalEntry 11 } ethIfIntervalMultipleCollisionFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of successfully transmitted frames for which transmission was inhibited by more than one collision, encountered by the Ethernet interface in one of the previous 96, individual 15 minute, intervals." ::= { ethIfIntervalEntry 12 } ethIfIntervalDeferredTransmissions OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted frames for which the first transmission attempt was delayed due to a busy media, encountered by the Ethernet interface in one of the previous 96, individual 15 minute, intervals." ::= { ethIfIntervalEntry 13 } ethIfIntervalLateCollisions OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of times that a collision was detected later than the first 64 bytes of the frame, encountered by the Ethernet interface in one of the previous 96, individual 15 minute, intervals." ::= { ethIfIntervalEntry 14 } ethIfIntervalCarrierSenseErrors OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of times that the carrier sense condition was lost or never asserted when attempting to transmit a frame, encountered by the Ethernet interface in one of the previous 96, individual 15 minute, intervals." ::= { ethIfIntervalEntry 15 } -- -- file :v:\doc\rdv\mib\ver480\tsa.txt -- --Title: RAD's WAN TSA (Time-Slot Assignment) MIB --By: Smadar Tauber --Date : 30.11.1998 --Last Update: 16/10/01 --By: Smadar --File: v:\doc\rdv\mib\ver480\tsa.txt --*********************************************************************** --Products that use this file WITHOUT the MPMX.TXT file,have to add the --following definitions to their *.pkb files: -- --wanGen OBJECT IDENTIFIER ::= {radWan 1} --agnWanGen OBJECT IDENTIFIER ::= {wanGen 2} --agnSystemTs OBJECT IDENTIFIER ::= {agnWanGen 11} --*********************************************************************** -- -- TS Assignment Table from system point of view -- agnTsTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnTsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= { agnSystemTs 1} agnTsEntry OBJECT-TYPE SYNTAX AgnTsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {agnTsCnfgIdx, agnTsSltIdx, agnTsPrtIdx, agnTsIdx, agnTsBitIdx, agnTsConSltIdx, agnTsConPrtIdx, agnTsConIdx } ::= { agnTsTable 1} AgnTsEntry ::= SEQUENCE { agnTsCnfgIdx Integer32, agnTsSltIdx INTEGER, agnTsPrtIdx Integer32, agnTsIdx Integer32, agnTsBitIdx Integer32, agnTsConSltIdx INTEGER, agnTsConPrtIdx Integer32, agnTsConIdx Integer32, agnTsType INTEGER, agnTsRowStatus RowStatus, agnTsDirection INTEGER } agnTsCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. " ::= { agnTsEntry 1} agnTsSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), io13 (17), io14 (18), io15 (19), notApplicable(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted." ::= { agnTsEntry 2} agnTsPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique external or internal port number. For MP, the valid values will be (for MLs only): - exPrt1(1)..exPrt4(4) - inPrt1(101)..inPrt4(104)" ::= { agnTsEntry 3} agnTsIdx OBJECT-TYPE SYNTAX Integer32 (1..32) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique index for TS (Time-Slot). - for T1 ports - 1..24, Fbit(25) - for E1 ports - 1..31 - for HDSL ports - 1..32 ; 32 will represent TS0." ::= { agnTsEntry 4} agnTsBitIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique index for the Bit of each TS (Time-Slot). 1..8 - Bit 1.. Bit 8 255 - notApplicable This object is applicable only in Split Time-Slot cases." ::= { agnTsEntry 5} agnTsConSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), io13 (17), io14 (18), io15 (19), notApplicable(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position In the Mux where the TS is routed to." ::= { agnTsEntry 6} agnTsConPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port id the TS is routed to. notApplicable - when agnTsType=mng or spare For MP: exPrt1 (1) .. exPrt16 (16) , notApplicable(100), inPrt1 (101) .. inPrt48 (148). " ::= { agnTsEntry 7} agnTsConIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique TS number the Src TS is routed to. Valid values: - for T1 ports - 1..24, Fbit(25) - for E1 ports - 1..31 - for HDSL ports - 1..32 ; 32 will represent TS0. - notApplicable - 255 (for ports that don't have TSs)." ::= { agnTsEntry 8} agnTsType OBJECT-TYPE SYNTAX INTEGER { unknown (1), voice (2), data (3), vcMP (4), mng (6), spare (7), reserved (8), dChannel (9) } MAX-ACCESS read-create STATUS current DESCRIPTION "Time-Slot Type - regarding its connection and media type. voice, data, vcMP - connected and the media is specified. mng - management. This TS is Dedicated to Management (not disconnected, but not connected to another port). spare - applicable for ML-20 only. These TSs should be reserved for future connection, though at the moment are not connected. reserved - these TSs are not connected, but they are Reserved for Protection (back-up) of a certain Path. Therefore, should NOT be used for connection of other Paths. dChannel - is used only when the TS is connected to a V5.1 ML (Bypass) and it contains ISDN D Channel data. In this case, agnTsConSltIdx, agnTsConPrtIdx and agnTsConIdx, will be 'notApplicable', since no TS is assigned for D Ch in V5.1 ML." ::= { agnTsEntry 9} agnTsRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute allows to create/delete a row in this table. For creating a row, the NMS should set agnTsRowStatus.255.id2.id3.id4.id5.id6.id7.id8 = active(1). For destroying a row, the NMS should set: agnTsRowStatus.255.id2.id3.id4.id5.id6.id7.id8 = destroy(6). Only rows with status active(1) are relevant. The only possible supported RowStatus vaules are active (1) and destroy (6)." ::= { agnTsEntry 10} agnTsDirection OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), rx (2), tx (3), both (4), bcastSrc (5), bcastDst (6), internal (7) } MAX-ACCESS read-create STATUS current DESCRIPTION "Direction of the connection. This parameter is especially important when in MP a ML is connected to an IO port that has no TSs, so it doesn't appear in the TS Assignment for the first 5 indexes. notApplicable - for products that do not support this object or for certain TS Types (for example: mng, spare) rx - the ML only Receives from the IO Port (the ML will appear in the first 5 indexes). tx - the ML only Transmits to the IO Port (the ML will appear in the first 5 indexes). Nothing is received back. both - the ML Receives and Transmits to the IO Port (the ML will appear in the first 5 indexes). bcastSrc - the ML is a Broadcast-Bidirectional Source. It Transmits to one or several IO Ports (including the one that appears in the last 3 indexes) and sometimes receives. The Port that responds is dynamic (it can be another each time). The ML will appear in the first 5 indexes. bcastDst - the ML is a Broadcast-Bidirectional Destination. Therefore, it Receives and sometimes Transmits. The ML will appear in the first 5 indexes. internal - for connection of TSs internally, within the same card. Such an assignment has no effect on the external TS connections of the same TS. A TS can be connected with 'internal' direction to a port of the same card and at the same time, connected by another direction to ports (and TSs) of other cards." ::= { agnTsEntry 11} -- -- file :v:\doc\rdv\mib\Before~1\sps5.txt -- -- Title: PS MIB -- -- -- Version: 1.0 -- Date: February 1, 95 -- By: Debby Koren -- Updated: Orly Nicklass, Smadar Tauber, Yair Arian, Liora Gafni -- Last update: 07-Oct-99 -- Comments: This is the Packet Switching branch in the RAD MIB -- X121Address ::= OCTET STRING (SIZE(0..17)) -- 0 to 17 bytes in length containing the ASCII -- characters [0-9], each octet contains one digit -- of the address. -- radPS OBJECT IDENTIFIER ::= { rad 8 } -- The groups in this MIB are the PS System Group, the Async Group, the Link Table, X.25 Group, -- HDLC Table, STM Table. Whenever an object appears twice with only the final -- character in the object name differing, the object whose name ends with S is read-write, and represents -- a scratch value that will take effect upon an activate imperitive action. The object whose name ends -- with A represents the current active value and is read-only. This was done to protect the user against -- inadvertantly disturbing active communications and to allow switchover to a different set of parameters -- in real time. -- The PS System Group contains all the PS system wide cofiguration parameters -- and the Routing Table pktSwchSystem OBJECT IDENTIFIER ::= { radPS 1} pktSwchSysParam OBJECT IDENTIFIER ::= { pktSwchSystem 1 } pktSwchSysSParam OBJECT IDENTIFIER ::= { pktSwchSysParam 1 } pktSwchSysX28PromptS OBJECT-TYPE SYNTAX DisplayString (SIZE (0..10)) MAX-ACCESS read-write STATUS current DESCRIPTION "This specifies a different PAD prompt, instead of the standard default character, the *. Up to 10 characters can be entered." ::= { pktSwchSysSParam 1 } pktSwchSysHeraldS OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "This specifies the PAD herald message for the SPS-6 and SPS-12. Up to 32 characters can be entered. Other devices will return a zero length octet string and will send an error if this object is set to a string of any other length." ::= { pktSwchSysSParam 2 } pktSwchSysBulletinS OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "This specifies the PAD bulletin message. Up to 32 characters can be entered." ::= { pktSwchSysSParam 3 } pktSwchSysComPortSubAddS OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "This is the scratch command port with the desired subaddress." ::= { pktSwchSysSParam 4 } pktSwchSysComPortAltSubAddS OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "This configures the command port with the second subaddress." ::= { pktSwchSysSParam 5 } pktSwchSysInnerCommLenS OBJECT-TYPE SYNTAX Integer32 (1..5) MAX-ACCESS read-write STATUS current DESCRIPTION "This specifies the address length in digits for Inner Communication." ::= { pktSwchSysSParam 6 } pktSwchSysXOnCharS OBJECT-TYPE SYNTAX Integer32 (0..127) MAX-ACCESS read-write STATUS current DESCRIPTION "The ASCII code of the software flow control character that will be used to start/renew the data transfer." ::= { pktSwchSysSParam 7 } pktSwchSysXOffCharS OBJECT-TYPE SYNTAX Integer32 (0..127) MAX-ACCESS read-write STATUS current DESCRIPTION "The ASCII code of the software flow control character that will be used to stop the data transfer." ::= { pktSwchSysSParam 8 } pktSwchSysMaxLcnS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum number of LCNs on the device." ::= { pktSwchSysSParam 9 } pktSwchSysMaxAIDS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum number of AIDs on the device." ::= { pktSwchSysSParam 10 } pktSwchSysDeviceIdS OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The device Id." ::= { pktSwchSysSParam 11 } pktSwchSysAParam OBJECT IDENTIFIER ::= { pktSwchSysParam 2 } pktSwchSysX28PromptA OBJECT-TYPE SYNTAX DisplayString (SIZE (0..10)) MAX-ACCESS read-only STATUS current DESCRIPTION "This specifies the active PAD prompt." ::= { pktSwchSysAParam 1 } pktSwchSysHeraldA OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "This specifies the active PAD herald message for the SPS-6 and SPS-12. Other devices will return a zero length string." ::= { pktSwchSysAParam 2 } pktSwchSysBulletinA OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "This indicates the active PAD bulletin message." ::= { pktSwchSysAParam 3 } pktSwchSysComPortSubAddA OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This is the active command port with the desired subaddress." ::= { pktSwchSysAParam 4 } pktSwchSysComPortAltSubAddA OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This is the active command port with the second subaddress." ::= { pktSwchSysAParam 5 } pktSwchSysInnerCommLenA OBJECT-TYPE SYNTAX Integer32 (1..5) MAX-ACCESS read-only STATUS current DESCRIPTION "This specifies the active address length in digits for Inner Communication." ::= { pktSwchSysAParam 6 } pktSwchSysXOnCharA OBJECT-TYPE SYNTAX Integer32 (0..127) MAX-ACCESS read-only STATUS current DESCRIPTION "The activeASCII code of the software flow control character that is used to start/renew the data transfer." ::= { pktSwchSysAParam 7 } pktSwchSysXOffCharA OBJECT-TYPE SYNTAX Integer32 (0..127) MAX-ACCESS read-only STATUS current DESCRIPTION "The active ASCII code of the software flow control character that is used to stop the data transfer." ::= { pktSwchSysAParam 8 } pktSwchSysMaxLcnA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The active maximum number of LCNs on the device." ::= { pktSwchSysAParam 9 } pktSwchSysMaxAIDA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The active maximum number of AIDs on the device." ::= { pktSwchSysAParam 10 } pktSwchSysDeviceIdA OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The device Id." ::= { pktSwchSysAParam 11 } pktSwchSysEvRepS OBJECT IDENTIFIER ::= { pktSwchSysParam 3 } pktSwchSysEvRepAdd1S OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This specifies the X.25 address to which the reports selected by means of pktSwchSysEvRepMask1S and pktSwchSysEvRepPeriod1S will be sent." ::= { pktSwchSysEvRepS 1 } pktSwchSysEvRepAdd2S OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This specifies the X.25 address to which the reports selected by means of pktSwchSysEvRepMask2S and pktSwchSysEvRepPeriod2S will be sent." ::= { pktSwchSysEvRepS 2 } pktSwchSysEvRepMask1S OBJECT-TYPE SYNTAX Integer32 (0..15) MAX-ACCESS read-write STATUS current DESCRIPTION "This specifies the conditions on which reports are sent to the address specified in pktSwchSysEvRepAdd1S. The value is a sum of values (powers of two), where each value in the sum represents a condition. The values that may be included in the sum and their meanings are: 0 Disable event reports 1 Send report when SYNC status has changed 2 Send report when RTS status has changed 4 Send report at Power On (Reset) 8 Report charging information at CLR." ::= { pktSwchSysEvRepS 3 } pktSwchSysEvRepPeriod1S OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "This specifies the time interval in minutes at which periodic reports are sent to the address specified in pktSwchSysEvRepAdd1S. A value of zero indicates that periodic reports are disabled." ::= { pktSwchSysEvRepS 4 } pktSwchSysEvRepMask2S OBJECT-TYPE SYNTAX Integer32 (0..15) MAX-ACCESS read-write STATUS current DESCRIPTION "This specifies the conditions on which reports are sent to the address specified in pktSwchSysEvRepAdd2S. The value is a sum of values (powers of two), where each value in the sum represents a condition. The values that may be included in the sum and their meanings are: 0 Disable event reports 1 Send report when SYNC status has changed 2 Send report when RTS status has changed 4 Send report at Power On (Reset) 8 Report charging information at CLR." ::= { pktSwchSysEvRepS 5 } pktSwchSysEvRepPeriod2S OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "This specifies the time interval in minutes at which periodic reports are sent to the address specified in pktSwchSysEvRepAdd2S. A value of zero indicates that periodic reports are disabled." ::= { pktSwchSysEvRepS 6 } pktSwchSysEvRepRetryCntS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Number of retries to send Event Reports to each port. Possible values: 0 - Disable retry mechanism 1-255 - Number of retries " ::= { pktSwchSysEvRepS 7 } pktSwchSysEvRepRetryDelayS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Time interval between retries (in minutes). Valid values: 1-255 " ::= { pktSwchSysEvRepS 8 } pktSwchSysEvRepRetryOptionsS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Event report options. The value is a sum of values (powers of two), where each value in the sum represents an option. The values that may be included in the sum and their meanings are: 0 - No Options 1 - Alternate Mode: Port 1 reports are readdressed to Port 2 on failure. (Port 2 mask is not used). 2 - Condensed Format X - Any combination of the above values " ::= { pktSwchSysEvRepS 9 } pktSwchSysEvRepA OBJECT IDENTIFIER ::= { pktSwchSysParam 4 } pktSwchSysEvRepAdd1A OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This specifies the active X.25 address to which the reports selected by means of pktSwchSysEvRepMask1A and pktSwchSysEvRepPeriod1A will be sent." ::= { pktSwchSysEvRepA 1 } pktSwchSysEvRepAdd2A OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This specifies the active X.25 address to which the reports selected by means of pktSwchSysEvRepMask2A and pktSwchSysEvRepPeriod2A will be sent." ::= { pktSwchSysEvRepA 2 } pktSwchSysEvRepMask1A OBJECT-TYPE SYNTAX Integer32 (0..15) MAX-ACCESS read-only STATUS current DESCRIPTION "This specifies the active conditions on which reports are sent to the address specified in pktSwchSysEvRepAdd1A. The value is a sum of values (powers of two), where each value in the sum represents a condition. The values that may be included in the sum and their meanings are: 0 Disable event reports 1 Send report when SYNC status has changed 2 Send report when RTS status has changed 4 Send report at Power On (Reset) 8 Report charging information at CLR." ::= { pktSwchSysEvRepA 3 } pktSwchSysEvRepPeriod1A OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This specifies the active time interval in minutes at which periodic reports are sent to the address specified in pktSwchSysEvRepAdd1A. A value of zero indicates that periodic reports are disabled." ::= { pktSwchSysEvRepA 4 } pktSwchSysEvRepMask2A OBJECT-TYPE SYNTAX Integer32 (0..15) MAX-ACCESS read-only STATUS current DESCRIPTION "This specifies the active conditions on which reports are sent to the address specified in pktSwchSysEvRepAdd2A. The value is a sum of values (powers of two), where each value in the sum represents a condition. The values that may be included in the sum and their meanings are: 0 Disable event reports 1 Send report when SYNC status has changed 2 Send report when RTS status has changed 4 Send report at Power On (Reset) 8 Report charging information at CLR." ::= { pktSwchSysEvRepA 5 } pktSwchSysEvRepPeriod2A OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This specifies the active time interval in minutes at which periodic reports are sent to the address specified in pktSwchSysEvRepAdd2A. A value of zero indicates that periodic reports are disabled." ::= { pktSwchSysEvRepA 6 } pktSwchSysEvRepRetryCntA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of retries to send Event Reports to each port. Possible values: 0 - Disable retry mechanism 1-255 - Number of retries " ::= { pktSwchSysEvRepA 7 } pktSwchSysEvRepRetryDelayA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Time interval between retries (in minutes). Valid values: 1-255 " ::= { pktSwchSysEvRepA 8 } pktSwchSysEvRepRetryOptionsA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Event report options. The value is a sum of values (powers of two), where each value in the sum represents an option. The values that may be included in the sum and their meanings are: 0 - No Options 1 - Alternate Mode: Port 1 reports are readdressed to Port 2 on failure. (Port 2 mask is not used). 2 - Condensed Format X - Any combination of the above values " ::= { pktSwchSysEvRepA 9 } pktSwchSysGen OBJECT IDENTIFIER ::= { pktSwchSysParam 5 } pktSwchSysDate OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This is used to update the date on the device." ::= { pktSwchSysGen 1 } pktSwchSysTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This is used to update the time on the device." ::= { pktSwchSysGen 2 } pktSwchSysAction OBJECT-TYPE SYNTAX INTEGER { noOp(1), reset(2), resetStat(3), rearrangeNovram(4), setDefaultConfig(5) } MAX-ACCESS read-write STATUS current DESCRIPTION "This is used to perform imperitive commands on the device. The reset command resets the device with the scratch values." ::= { pktSwchSysGen 3 } pktSwchSysRamSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The RAM size on the device." ::= { pktSwchSysGen 4 } pktSwchSysNovramSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The NOVRAM size on the device." ::= { pktSwchSysGen 5 } pktSwchSysNovramUtil OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The NOVRAM utilization on the device." ::= { pktSwchSysGen 6 } pktSwchSysFreeDataBuff OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The free data buffers on the device." ::= { pktSwchSysGen 7 } pktSwchSysMinDataBuffInPool OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum data buffers in the pool on the device." ::= { pktSwchSysGen 8 } pktSwchSysProtocols OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The protocols the device can support. The value is a sum of values (powers of two), where each value in the sum represents a protocol. The values that may be included in the sum and their meanings are: 1 X.25 2 Frame Relay 4 HDLC 8 SDLC 16 MPE 32 ASYNC 64 STM-4 128 STM-8 256 STM-16 512 STM-24 1024 BISYNC 2048 SLIP 4096 ETHERNET 8192 PPP 16384 ISDN XX - Any combination of the values specified above ." ::= { pktSwchSysGen 9 } pktSwchSysChannelProtocols OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The protocols the device can support on the async channels. 1 ASYNC 2 SLIP 3 PPP " ::= { pktSwchSysGen 10 } pktSwchSysStatus OBJECT-TYPE SYNTAX INTEGER { valid(1), createRequest(2), underCreation(3), invalid(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The status of the System data. The choices are those defined in the SNMPv2 Textual Conventions for RowStatus. This will allow easy replacement of the INTEGER syntax with the RowStatus textual convention SYNTAX." ::= { pktSwchSysParam 6 } -- The routing subgroup in the pktSwch System Group contains the routing table, the local PVC table -- and the net PVC table pktSwchRouting OBJECT IDENTIFIER ::= { pktSwchSystem 2} pktSwchRoutSTable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchRoutSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Scratch Routing Table defines the routes for incoming and outgoing data on the device." ::= { pktSwchRouting 1 } pktSwchRoutSEntry OBJECT-TYPE SYNTAX PktSwchRoutSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in the Scratch Routing Table." INDEX { pktSwchRoutIdS } ::= { pktSwchRoutSTable 1 } PktSwchRoutSEntry ::= SEQUENCE { pktSwchRoutIdS Integer32, pktSwchRoutAddressS DisplayString, pktSwchRoutDestLink1S DisplayString, pktSwchRoutDestLink2S DisplayString, pktSwchRoutDestLink3S DisplayString, pktSwchRoutLinkPrio1S Integer32, pktSwchRoutLinkPrio2S Integer32, pktSwchRoutLinkPrio3S Integer32, pktSwchRoutSearchStatusS INTEGER, pktSwchRoutStatusS INTEGER } pktSwchRoutIdS OBJECT-TYPE SYNTAX Integer32 (1..2000) MAX-ACCESS read-write STATUS current DESCRIPTION "Index of the pktSwchRoutSTable." ::= { pktSwchRoutSEntry 1 } pktSwchRoutAddressS OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The address to which the entry applies. The use of the octet string syntax allows the use of the letter x as a wild card in the addresses." ::= { pktSwchRoutSEntry 2 } pktSwchRoutDestLink1S OBJECT-TYPE SYNTAX DisplayString -- (SIZE(6)) MAX-ACCESS read-write STATUS current DESCRIPTION "First destination link through which the data will be routed. For X.25 destination: any valid x.25 link no. For Frame Relay Link: any valid dlci with an x.25 encapsulation protocol, presented in the form of {port:dlci}. For a local destination: 100 . For ISDN: ISDN routing entry number preceeded by the letter 'I' (example: I4)" ::= { pktSwchRoutSEntry 3 } pktSwchRoutDestLink2S OBJECT-TYPE SYNTAX DisplayString -- (SIZE(6)) MAX-ACCESS read-write STATUS current DESCRIPTION "Second destination link through which the data will be routed. For X.25 destination: any valid x.25 link no. For Frame Relay Link: any valid dlci with an x.25 encapsulation protocol, presented in the form of {port:dlci}. For a local destination: 100 . For ISDN: ISDN routing entry number preceeded by the letter 'I' (example: I4)" ::= { pktSwchRoutSEntry 4 } pktSwchRoutDestLink3S OBJECT-TYPE SYNTAX DisplayString -- (SIZE(6)) MAX-ACCESS read-write STATUS current DESCRIPTION "Third destination link through which the data will be routed. For X.25 destination: any valid x.25 link no. For Frame Relay Link: any valid dlci with an x.25 encapsulation protocol, presented in the form of {port:dlci}. For a local destination: 100 . For ISDN: ISDN routing entry number preceeded by the letter 'I' (example: I4)" ::= { pktSwchRoutSEntry 5 } pktSwchRoutLinkPrio1S OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "A priority of the associated destination of link 1." ::= { pktSwchRoutSEntry 6 } pktSwchRoutLinkPrio2S OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "A priority of the associated destination of link 2." ::= { pktSwchRoutSEntry 7 } pktSwchRoutLinkPrio3S OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "A priority of the associated destination of link 3." ::= { pktSwchRoutSEntry 8 } pktSwchRoutSearchStatusS OBJECT-TYPE SYNTAX INTEGER { off(2), on(3) } MAX-ACCESS read-write STATUS current DESCRIPTION " off - The device stops searching for a matching address. on - The device continues searching for a matching address in the links of the next entry." ::= { pktSwchRoutSEntry 9 } pktSwchRoutStatusS OBJECT-TYPE SYNTAX INTEGER { valid(1), createRequest(2), underCreation(3), invalid(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The status of this routing table entry. The choices are those defined in the SNMPv2 Textual Conventions for RowStatus. This will allow easy replacement of the INTEGER syntax with the RowStatus textual convention SYNTAX." ::= { pktSwchRoutSEntry 10 } pktSwchRoutATable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchRoutAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Active Routing Table defines the active routes for incoming and outgoing data on the device." ::= { pktSwchRouting 2 } pktSwchRoutAEntry OBJECT-TYPE SYNTAX PktSwchRoutAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in the Active Routing Table." INDEX { pktSwchRoutIdA } ::= { pktSwchRoutATable 1 } PktSwchRoutAEntry ::= SEQUENCE { pktSwchRoutIdA Integer32, pktSwchRoutAddressA DisplayString, pktSwchRoutDestLink1A DisplayString, pktSwchRoutDestLink2A DisplayString, pktSwchRoutDestLink3A DisplayString, pktSwchRoutLinkPrio1A Integer32, pktSwchRoutLinkPrio2A Integer32, pktSwchRoutLinkPrio3A Integer32, pktSwchRoutSearchStatusA INTEGER } pktSwchRoutIdA OBJECT-TYPE SYNTAX Integer32 (1..2000) MAX-ACCESS read-only STATUS current DESCRIPTION "Index of the pktSwchRoutATable." ::= { pktSwchRoutAEntry 1 } pktSwchRoutAddressA OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The address to which the entry applies. The use of the octet string syntax allows the use of the letter x as a wild card in the addresses." ::= { pktSwchRoutAEntry 2 } pktSwchRoutDestLink1A OBJECT-TYPE SYNTAX DisplayString -- (SIZE(6)) MAX-ACCESS read-only STATUS current DESCRIPTION "First destination link through which the data will be routed. For X.25 destination: any valid x.25 link no. For Frame Relay Link: any valid dlci with an x.25 encapsulation protocol, presented in the form of {port:dlci}. For a local destination: 100 . For ISDN: ISDN routing entry number preceeded by the letter 'I' (example: I4)" ::= { pktSwchRoutAEntry 3 } pktSwchRoutDestLink2A OBJECT-TYPE SYNTAX DisplayString -- (SIZE(6)) MAX-ACCESS read-only STATUS current DESCRIPTION "Second destination link through which the data will be routed. For X.25 destination: any valid x.25 link no. For Frame Relay Link: any valid dlci with an x.25 encapsulation protocol, presented in the form of {port:dlci}. For a local destination: 100 . For ISDN: ISDN routing entry number preceeded by the letter 'I' (example: I4)" ::= { pktSwchRoutAEntry 4 } pktSwchRoutDestLink3A OBJECT-TYPE SYNTAX DisplayString -- (SIZE(6)) MAX-ACCESS read-only STATUS current DESCRIPTION "Third destination link through which the data will be routed. For X.25 destination: any valid x.25 link no. For Frame Relay Link: any valid dlci with an x.25 encapsulation protocol, presented in the form of {port:dlci}. For a local destination: 100 . For ISDN: ISDN routing entry number preceeded by the letter 'I' (example: I4)" ::= { pktSwchRoutAEntry 5 } pktSwchRoutLinkPrio1A OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A priority of the associated destination of link 1." ::= { pktSwchRoutAEntry 6 } pktSwchRoutLinkPrio2A OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A priority of the associated destination of link 2." ::= { pktSwchRoutAEntry 7 } pktSwchRoutLinkPrio3A OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A priority of the associated destination of link 3." ::= { pktSwchRoutAEntry 8 } pktSwchRoutSearchStatusA OBJECT-TYPE SYNTAX INTEGER { off(2), on(3) } MAX-ACCESS read-only STATUS current DESCRIPTION " off - The device stops searching for a matching address. on - The device continues searching for a matching address in the links of the next entry." ::= { pktSwchRoutAEntry 9 } pktSwchPvcSTable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchPvcSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Scratch Network PVC Table defines the network PVCs." ::= { pktSwchRouting 3 } pktSwchPvcSEntry OBJECT-TYPE SYNTAX PktSwchPvcSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in the Scratch Network PVC table." INDEX { pktSwchPvcNumS } ::= { pktSwchPvcSTable 1 } PktSwchPvcSEntry ::= SEQUENCE { pktSwchPvcNumS Integer32, pktSwchPvcSrcLinkS Integer32, pktSwchPvcSrcLcnS DisplayString, pktSwchPvcDstLinkS Integer32, pktSwchPvcDstLcnS Integer32, pktSwchPvcStatusS INTEGER } pktSwchPvcNumS OBJECT-TYPE SYNTAX Integer32 (1..200) MAX-ACCESS read-write STATUS current DESCRIPTION "The PVC number corresponding to this entry." ::= { pktSwchPvcSEntry 1 } pktSwchPvcSrcLinkS OBJECT-TYPE SYNTAX Integer32 (0..100) MAX-ACCESS read-write STATUS current DESCRIPTION "The number of the link (1 through 6 for SPS-6 and 1 through 12 for SPS-12) that will be used as a source link to create a connection by means of the PVC. 0 means that the PVC will not be active, 100 means that this pvc is Local." ::= { pktSwchPvcSEntry 2 } pktSwchPvcSrcLcnS OBJECT-TYPE SYNTAX DisplayString -- (SIZE(1..6)) MAX-ACCESS read-write STATUS current DESCRIPTION " Network pvc: The number of the logical channel (0-255) that will be used as the source logical channel to create a connection by means of the PVC. Local pvc: For asynchronous channel to X.25 PVC, Any valid Async Channel number. For encapsulation of transparent HDLC over X25 PVC, valid Channel numbers are: HxM - for the main PVC. HxB - for the backup PVC. x is a valid HDLC link number. For encapsulation of Multi Point Encapsulator (MPE) over X25 PVC, valid channel numbers are: Nx - where x is a valid MPE link number. For encapsulation of IP Over X.25 PVC, Enter IP." ::= { pktSwchPvcSEntry 3 } pktSwchPvcDstLinkS OBJECT-TYPE SYNTAX Integer32 (0..12) MAX-ACCESS read-write STATUS current DESCRIPTION "The number of the destination link that will be used. 0 means that the PVC will not be active." ::= { pktSwchPvcSEntry 4 } pktSwchPvcDstLcnS OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "The number of the logical channel for the destination link." ::= { pktSwchPvcSEntry 5 } pktSwchPvcStatusS OBJECT-TYPE SYNTAX INTEGER { valid(1), createRequest(2), underCreation(3), invalid(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The status of this Network PVC table entry. The choices are those defined in the SNMPv2 Textual Conventions for RowStatus. This will allow easy replacement of the INTEGER syntax with the RowStatus textual convention SYNTAX." ::= { pktSwchPvcSEntry 6 } pktSwchPvcATable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchPvcAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Active Network PVC Table defines the active network PVCs." ::= { pktSwchRouting 4 } pktSwchPvcAEntry OBJECT-TYPE SYNTAX PktSwchPvcAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in the Active Network PVC table." INDEX { pktSwchPvcNumA } ::= { pktSwchPvcATable 1 } PktSwchPvcAEntry ::= SEQUENCE { pktSwchPvcNumA Integer32, pktSwchPvcSrcLinkA Integer32, pktSwchPvcSrcLcnA DisplayString, pktSwchPvcDstLinkA Integer32, pktSwchPvcDstLcnA Integer32 } pktSwchPvcNumA OBJECT-TYPE SYNTAX Integer32 (1..200) MAX-ACCESS read-only STATUS current DESCRIPTION "The PVC number corresponding to this entry." ::= { pktSwchPvcAEntry 1 } pktSwchPvcSrcLinkA OBJECT-TYPE SYNTAX Integer32 (0..100) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of the link (1 through 6 for SPS-6 and 1 through 12 for SPS-12) that is used as a source link to create a connection by means of the PVC. 0 means that the PVC will not be active, 100 means that this pvc is Local." ::= { pktSwchPvcAEntry 2 } pktSwchPvcSrcLcnA OBJECT-TYPE SYNTAX DisplayString -- (SIZE(1..6)) MAX-ACCESS read-only STATUS current DESCRIPTION " Network pvc: The number of the logical channel (0-255) that will be used as the source logical channel to create a connection by means of the PVC. Local pvc: For asynchronous channel to X.25 PVC, Any valid Async Channel number. For encapsulation of transparent HDLC over X25 PVC, valid Channel numbers are: HxM - for the main PVC. HxB - for the backup PVC. x is a valid HDLC link number. For encapsulation of Multi Point Encapsulator (MPE) over X25 PVC, valid channel numbers are: Nx - where x is a valid MPE link number. For encapsulation of IP Over X.25 PVC, Enter IP." ::= { pktSwchPvcAEntry 3 } pktSwchPvcDstLinkA OBJECT-TYPE SYNTAX Integer32 (0..12) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of the destination link that is used. 0 means that the PVC will not be active." ::= { pktSwchPvcAEntry 4 } pktSwchPvcDstLcnA OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of the logical channel for the destination link." ::= { pktSwchPvcAEntry 5 } -- NUI Table pktSwchNui OBJECT IDENTIFIER ::= { pktSwchSystem 3 } -- The NUI Table contains the Network User Identification -- password information. pktSwchNuiSTable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchNuiSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The NUI Table defines the NUIs that can be used by the device." ::= { pktSwchNui 1 } pktSwchNuiSEntry OBJECT-TYPE SYNTAX PktSwchNuiSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in the NUI Table." INDEX { pktSwchNuiIndexS } ::= { pktSwchNuiSTable 1 } PktSwchNuiSEntry ::= SEQUENCE { pktSwchNuiIndexS Integer32, pktSwchNuiGroupIdS Integer32, pktSwchNuiInPasswdS DisplayString, pktSwchNuiOutPasswdPointerS Integer32, pktSwchNuiInAddrS DisplayString, pktSwchNuiOutAddrPointerS Integer32, pktSwchNuiStatusS INTEGER } pktSwchNuiIndexS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The index of this entry." ::= { pktSwchNuiSEntry 1 } pktSwchNuiGroupIdS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The group Id for this NUI entry." ::= { pktSwchNuiSEntry 2 } pktSwchNuiInPasswdS OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The password for the incoming call. 15 chars." ::= { pktSwchNuiSEntry 3 } pktSwchNuiOutPasswdPointerS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "A pointer to the password in the OutPasswdTable for an outgoing call." ::= { pktSwchNuiSEntry 4 } pktSwchNuiInAddrS OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The addresss for the incoming call. 15 digits." ::= { pktSwchNuiSEntry 5 } pktSwchNuiOutAddrPointerS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "A pointer to the address in the OutAddrTable for an outgoing call." ::= { pktSwchNuiSEntry 6 } pktSwchNuiStatusS OBJECT-TYPE SYNTAX INTEGER { valid(1), createRequest(2), underCreation(3), invalid(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The status of this NUI table entry. The choices are those defined in the SNMPv2 Textual Conventions for RowStatus. This will allow easy replacement of the INTEGER syntax with the RowStatus textual convention SYNTAX." ::= { pktSwchNuiSEntry 7 } pktSwchNuiATable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchNuiAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The NUI Table defines the NUIs that can be used by the device." ::= { pktSwchNui 2 } pktSwchNuiAEntry OBJECT-TYPE SYNTAX PktSwchNuiAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in the NUI Table." INDEX { pktSwchNuiIndexA } ::= { pktSwchNuiATable 1 } PktSwchNuiAEntry ::= SEQUENCE { pktSwchNuiIndexA Integer32, pktSwchNuiGroupIdA Integer32, pktSwchNuiInPasswdA DisplayString, pktSwchNuiOutPasswdPointerA Integer32, pktSwchNuiInAddrA DisplayString, pktSwchNuiOutAddrPointerA Integer32, pktSwchNuiStatusA INTEGER } pktSwchNuiIndexA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of this entry." ::= { pktSwchNuiAEntry 1 } pktSwchNuiGroupIdA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The group Id for this NUI entry." ::= { pktSwchNuiAEntry 2 } pktSwchNuiInPasswdA OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The password for the incoming call. 15 chars." ::= { pktSwchNuiAEntry 3 } pktSwchNuiOutPasswdPointerA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A pointer to the password in the OutPasswdTable for an outgoing call." ::= { pktSwchNuiAEntry 4 } pktSwchNuiInAddrA OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The addresss for the incoming call. 15 digits." ::= { pktSwchNuiAEntry 5 } pktSwchNuiOutAddrPointerA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A pointer to the address in the OutAddrTable for an outgoing call." ::= { pktSwchNuiAEntry 6 } pktSwchNuiStatusA OBJECT-TYPE SYNTAX INTEGER { valid(1), createRequest(2), underCreation(3), invalid(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of this NUI table entry. The choices are those defined in the SNMPv2 Textual Conventions for RowStatus. This will allow easy replacement of the INTEGER syntax with the RowStatus textual convention SYNTAX." ::= { pktSwchNuiAEntry 7 } pktSwchNuiOutPasswdSTable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchNuiOutPasswdSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table defines the passwords that can be used by the device." ::= { pktSwchNui 3 } pktSwchNuiOutPasswdSEntry OBJECT-TYPE SYNTAX PktSwchNuiOutPasswdSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in OutPasswd Table." INDEX { pktSwchNuiOutPasswdIndexS } ::= { pktSwchNuiOutPasswdSTable 1 } PktSwchNuiOutPasswdSEntry ::= SEQUENCE { pktSwchNuiOutPasswdIndexS Integer32, pktSwchNuiOutPasswdValueS DisplayString, pktSwchNuiOutPasswdStatusS INTEGER } pktSwchNuiOutPasswdIndexS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The index of this entry." ::= { pktSwchNuiOutPasswdSEntry 1 } pktSwchNuiOutPasswdValueS OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The password of this entry. 15 chars." ::= { pktSwchNuiOutPasswdSEntry 2 } pktSwchNuiOutPasswdStatusS OBJECT-TYPE SYNTAX INTEGER { valid(1), createRequest(2), underCreation(3), invalid(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The status of this NuiOutPasswd table entry." ::= { pktSwchNuiOutPasswdSEntry 3 } pktSwchNuiOutPasswdATable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchNuiOutPasswdAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table defines the passwords that can be used by the device." ::= { pktSwchNui 4 } pktSwchNuiOutPasswdAEntry OBJECT-TYPE SYNTAX PktSwchNuiOutPasswdAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in OutPasswd Table." INDEX { pktSwchNuiOutPasswdIndexA } ::= { pktSwchNuiOutPasswdATable 1 } PktSwchNuiOutPasswdAEntry ::= SEQUENCE { pktSwchNuiOutPasswdIndexA Integer32, pktSwchNuiOutPasswdValueA DisplayString, pktSwchNuiOutPasswdStatusA INTEGER } pktSwchNuiOutPasswdIndexA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of this entry." ::= { pktSwchNuiOutPasswdAEntry 1 } pktSwchNuiOutPasswdValueA OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The password of this entry. 15 chars." ::= { pktSwchNuiOutPasswdAEntry 2 } pktSwchNuiOutPasswdStatusA OBJECT-TYPE SYNTAX INTEGER { valid(1), createRequest(2), underCreation(3), invalid(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of this NuiOutPasswd table entry." ::= { pktSwchNuiOutPasswdAEntry 3 } pktSwchNuiOutAddrSTable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchNuiOutAddrSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table defines the Addresses that can be used by the device." ::= { pktSwchNui 5 } pktSwchNuiOutAddrSEntry OBJECT-TYPE SYNTAX PktSwchNuiOutAddrSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in OutAddr Table." INDEX { pktSwchNuiOutAddrIndexS } ::= { pktSwchNuiOutAddrSTable 1 } PktSwchNuiOutAddrSEntry ::= SEQUENCE { pktSwchNuiOutAddrIndexS Integer32, pktSwchNuiOutAddrValueS DisplayString, pktSwchNuiOutAddrStatusS INTEGER } pktSwchNuiOutAddrIndexS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The index of this entry." ::= { pktSwchNuiOutAddrSEntry 1 } pktSwchNuiOutAddrValueS OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The address of this entry. 15 digits." ::= { pktSwchNuiOutAddrSEntry 2 } pktSwchNuiOutAddrStatusS OBJECT-TYPE SYNTAX INTEGER { valid(1), createRequest(2), underCreation(3), invalid(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The status of this NuiOutAddr table entry." ::= { pktSwchNuiOutAddrSEntry 3 } pktSwchNuiOutAddrATable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchNuiOutAddrAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table defines the Addresses that can be used by the device." ::= { pktSwchNui 6 } pktSwchNuiOutAddrAEntry OBJECT-TYPE SYNTAX PktSwchNuiOutAddrAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in OutAddr Table." INDEX { pktSwchNuiOutAddrIndexA } ::= { pktSwchNuiOutAddrATable 1 } PktSwchNuiOutAddrAEntry ::= SEQUENCE { pktSwchNuiOutAddrIndexA Integer32, pktSwchNuiOutAddrValueA DisplayString, pktSwchNuiOutAddrStatusA INTEGER } pktSwchNuiOutAddrIndexA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of this entry." ::= { pktSwchNuiOutAddrAEntry 1 } pktSwchNuiOutAddrValueA OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The address of this entry. 15 digits." ::= { pktSwchNuiOutAddrAEntry 2 } pktSwchNuiOutAddrStatusA OBJECT-TYPE SYNTAX INTEGER { valid(1), createRequest(2), underCreation(3), invalid(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of this NuiOutAddr table entry." ::= { pktSwchNuiOutAddrAEntry 3 } -- X25 Manager Table pktSwchMng OBJECT IDENTIFIER ::= { pktSwchSystem 4 } pktSwchMngX25TrapIpTable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchMngX25Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table indicates the destination address of the traps. Internally it will be limited to ten addresses. " ::= { pktSwchMng 1 } pktSwchMngX25Entry OBJECT-TYPE SYNTAX PktSwchMngX25Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table pktSwchMngX25TrapIpTable." INDEX { pktSwchMngID } ::= {pktSwchMngX25TrapIpTable 1 } PktSwchMngX25Entry ::= SEQUENCE { pktSwchMngID Integer32, pktSwchMngIP IpAddress, pktSwchMngPhyAddr DisplayString, pktSwchTrapEnable Integer32, pktSwchEncapsulationMode INTEGER } pktSwchMngID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " This value indicates an index of a specific IP address" ::= { pktSwchMngX25Entry 1 } pktSwchMngIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "This value indicates the destination address of the traps. IP 0.0.0.0 removes the entry. " ::= { pktSwchMngX25Entry 2 } pktSwchMngPhyAddr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This value indicates the physical destination address of the traps." ::= { pktSwchMngX25Entry 3 } pktSwchTrapEnable OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This value indicates which traps should be sent. The value is a sum of values (powers of two), where each value in the sum represents a trap that should be reported to the Management Station. The values that may be included in the sum and their meanings are: 0 No traps would be reported. 1 Link Down 2 Link Up 4 rtsChange 8 resetX25 16 restartX25 32 frDLCIStatusChange 64 coldStart 128 linkProtocolChanged 256 enrollmentPS 512 ledStatusChange " ::= { pktSwchMngX25Entry 4 } pktSwchEncapsulationMode OBJECT-TYPE SYNTAX INTEGER { ipPid(1), snapPid(2) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Format type for IP over X25" ::= { pktSwchMngX25Entry 5 } -- XID Table pktSwchXid OBJECT IDENTIFIER ::= { pktSwchSystem 5 } pktSwchXidSTable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchXidSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Exchange Id table contains a list of 13 incoming pairs of allowed dial-up phone numbers and passwords. Also included is one pair of outgoing phone number and password (InternalIndex=14)." ::= { pktSwchXid 1 } pktSwchXidSEntry OBJECT-TYPE SYNTAX PktSwchXidSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table pktSwchXidSTable." INDEX { pktSwchXidIndexS, pktSwchXidInternalIndexS } ::= {pktSwchXidSTable 1 } PktSwchXidSEntry ::= SEQUENCE { pktSwchXidIndexS Integer32, pktSwchXidInternalIndexS Integer32, pktSwchXidPasswdS DisplayString, pktSwchXidPhoneS DisplayString, pktSwchXidStatusS INTEGER } pktSwchXidIndexS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " This Index of the XID table." ::= { pktSwchXidSEntry 1 } pktSwchXidInternalIndexS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "An internal index for each XidIndex of the table. The first 13 entries refer to Incoming calls. The 14th entry refers to an Outgoing call." ::= { pktSwchXidSEntry 2 } pktSwchXidPasswdS OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Password of size 16 chars." ::= { pktSwchXidSEntry 3 } pktSwchXidPhoneS OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Phone number of size 16 digits." ::= { pktSwchXidSEntry 4 } pktSwchXidStatusS OBJECT-TYPE SYNTAX INTEGER { valid(1), createRequest(2), underCreation(3), invalid(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The status of the XID table entry. The status applies to the XidIndex, i.e., setting the staus to invalid results in the removal of all the InternalIndex entries (1..14) belonging to the relevant XidIndex." ::= { pktSwchXidSEntry 5 } pktSwchXidATable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchXidAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Exchange Id table contains a list of 13 incoming pairs of allowed dial-up phone numbers and passwords. Also included is one pair of outgoing phone number and password (InternalIndex=14)." ::= { pktSwchXid 2 } pktSwchXidAEntry OBJECT-TYPE SYNTAX PktSwchXidAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table pktSwchXidATable." INDEX { pktSwchXidIndexA, pktSwchXidInternalIndexA } ::= {pktSwchXidATable 1 } PktSwchXidAEntry ::= SEQUENCE { pktSwchXidIndexA Integer32, pktSwchXidInternalIndexA Integer32, pktSwchXidPasswdA DisplayString, pktSwchXidPhoneA DisplayString, pktSwchXidStatusA INTEGER } pktSwchXidIndexA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " This Index of the XID table." ::= { pktSwchXidAEntry 1 } pktSwchXidInternalIndexA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "An internal index for each XidIndex of the table. The first 13 entries refer to Incoming calls. The 14th entry refers to an Outgoing call." ::= { pktSwchXidAEntry 2 } pktSwchXidPasswdA OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Password of size 16 chars." ::= { pktSwchXidAEntry 3 } pktSwchXidPhoneA OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Phone number of size 16 digits." ::= { pktSwchXidAEntry 4 } pktSwchXidStatusA OBJECT-TYPE SYNTAX INTEGER { valid(1), createRequest(2), underCreation(3), invalid(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the XID table entry. The status applies to the XidIndex, i.e., setting the staus to invalid results in the removal of all the InternalIndex entries (1..14) belonging to the relevant XidIndex." ::= { pktSwchXidAEntry 5 } pktSwchIpRouting OBJECT IDENTIFIER ::= { pktSwchSystem 6 } pktSwchIpRoutSTable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchIpRoutSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Scratch Routing Table defines the routes for incoming and outgoing ip datagrams on the device." ::= { pktSwchIpRouting 1 } pktSwchIpRoutSEntry OBJECT-TYPE SYNTAX PktSwchIpRoutSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in the Scratch IP Routing Table." INDEX { pktSwchIpRoutIdS } ::= { pktSwchIpRoutSTable 1 } PktSwchIpRoutSEntry ::= SEQUENCE { pktSwchIpRoutIdS Integer32, pktSwchIpRoutIpAddressS IpAddress, pktSwchIpRoutIpMaskS IpAddress, pktSwchIpRoutDestProtocolS INTEGER, pktSwchIpRoutDestinationS DisplayString, pktSwchIpRoutInactivityS Integer32, pktSwchIpRoutStatusS INTEGER, pktSwchIpRoutMetricS Integer32, pktSwchIpRoutNextHopS IpAddress, pktSwchIpRoutInterfaceIdS Integer32 } pktSwchIpRoutIdS OBJECT-TYPE SYNTAX Integer32 (1..200) MAX-ACCESS read-write STATUS current DESCRIPTION "Index of the pktSwchIpRoutSTable." ::= { pktSwchIpRoutSEntry 1 } pktSwchIpRoutIpAddressS OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The IP address to which the entry applies. A string of the format: X.X.X.X where every X is a number in the range 0-255." ::= { pktSwchIpRoutSEntry 2 } pktSwchIpRoutIpMaskS OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The IP mask to which the entry applies. A string of the format: X.X.X.X where every X is a number in the range 0-255." ::= { pktSwchIpRoutSEntry 3 } pktSwchIpRoutDestProtocolS OBJECT-TYPE SYNTAX INTEGER { slip (1), x25SVC (2), x25PVC (3), frameRelay (4), hdlc (5), ethernet (7), -- (6) is reserved for snmp agent. ppp (8), none (255) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Destination protocol for the associated address. None(255) when not used" ::= { pktSwchIpRoutSEntry 4 } pktSwchIpRoutDestinationS OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS deprecated DESCRIPTION " Destination for the associated address. Possible values: Default : Not Used. X.25 PVC: Port:LCN or a pre defined PVC number X.25 SVC: X.25 Addr or cid followed by a predefined Call ID number Frame Relay: Port:DLCI HDLC: 'H' followed by the HDLC Port Number SLIP: 'S' followed by the SLIP Channel Number Ethernet: 'E' followed by the Ethernet Port Number PPP: 'P' followed by the PPP Port Number." ::= { pktSwchIpRoutSEntry 5 } pktSwchIpRoutInactivityS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Inactivity time in steps of 50 mili seconds for X25 SVC protocol only. Range: 0..255. Default: 2." ::= { pktSwchIpRoutSEntry 6 } pktSwchIpRoutStatusS OBJECT-TYPE SYNTAX INTEGER { valid (1), createRequest(2), underCreation(3), invalid (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The status of this routing table entry. The choices are those defined in the SNMPv2 Textual Conventions for RowStatus. This will allow easy replacement of the INTEGER syntax with the RowStatus textual convention SYNTAX." ::= { pktSwchIpRoutSEntry 7 } pktSwchIpRoutMetricS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "No. of hops for this route. The default value is 1. Legal values: 1 to the max no. of hops this device will support. The max no. is defined by pktSwchIpGlobalMaxHopCount." ::= { pktSwchIpRoutSEntry 8 } pktSwchIpRoutNextHopS OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "IP address of the next hop. A string of the format: X.X.X.X where every X is a number in the range 0-255." ::= { pktSwchIpRoutSEntry 9 } pktSwchIpRoutInterfaceIdS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "ID of the logical IP interface in the pktSwchIpInterface table. The IP routing module will route the IP frame according to this interface ID. Legal values: 1 to 200 and 65535. 1-200 : ID of interface. 65535 : No IP interface ID. Default value: 65535." ::= { pktSwchIpRoutSEntry 10 } pktSwchIpRoutATable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchIpRoutAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Active Routing Table defines the active routes for incoming and outgoing ip datagrams on the device." ::= { pktSwchIpRouting 2 } pktSwchIpRoutAEntry OBJECT-TYPE SYNTAX PktSwchIpRoutAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in the Active IP Routing Table." INDEX { pktSwchIpRoutIdA } ::= { pktSwchIpRoutATable 1 } PktSwchIpRoutAEntry ::= SEQUENCE { pktSwchIpRoutIdA Integer32, pktSwchIpRoutIpAddressA IpAddress, pktSwchIpRoutIpMaskA IpAddress, pktSwchIpRoutDestProtocolA INTEGER, pktSwchIpRoutDestinationA DisplayString, pktSwchIpRoutInactivityA Integer32, pktSwchIpRoutBuffsInA Counter32, pktSwchIpRoutBuffsOutA Counter32, pktSwchIpRoutFCA INTEGER, pktSwchIpRoutMetricA Integer32, pktSwchIpRoutNextHopA IpAddress, pktSwchIpRoutInterfaceIdA Integer32 } pktSwchIpRoutIdA OBJECT-TYPE SYNTAX Integer32 (1..200) MAX-ACCESS read-only STATUS current DESCRIPTION "Index of the IP pktSwchIpRoutATable." ::= { pktSwchIpRoutAEntry 1 } pktSwchIpRoutIpAddressA OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The IP address to which the entry applies. A string of the format: X.X.X.X where every X is a number in the range 0-255." ::= { pktSwchIpRoutAEntry 2 } pktSwchIpRoutIpMaskA OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The IP mask to which the entry applies. A string of the format: X.X.X.X where every X is a number in the range 0-255." ::= { pktSwchIpRoutAEntry 3 } pktSwchIpRoutDestProtocolA OBJECT-TYPE SYNTAX INTEGER { slip (1), x25SVC (2), x25PVC (3), frameRelay (4), hdlc (5), snmpAgent (6), ethernet (7), ppp (8), none (255) } MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Destination protocol for the associated address. None(255) when not used." ::= { pktSwchIpRoutAEntry 4 } pktSwchIpRoutDestinationA OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS deprecated DESCRIPTION " Destination for the associated address. Possible values: Default : Not Used. X.25 PVC: Port:LCN or a pre defined PVC number X.25 SVC: X.25 Addr or cid followed by a predefined Call ID number Frame Relay: Port:DLCI HDLC: 'H' followed by the HDLC Port Number SLIP: 'S' followed by the SLIP Channel Number Ethernet: 'E' followed by the Ethernet Port Number PPP: 'P' followed by the PPP Port Number." ::= { pktSwchIpRoutAEntry 5 } pktSwchIpRoutInactivityA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Inactivity time in steps of 50 mili seconds for X25 SVC protocol only. Range: 0..255. Default: 2." ::= { pktSwchIpRoutAEntry 6 } pktSwchIpRoutBuffsInA OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of packets in the Input buffer link list, received but not routed yet." ::= { pktSwchIpRoutAEntry 7 } pktSwchIpRoutBuffsOutA OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of packets in the Output buffer link list, routed but not sent yet." ::= { pktSwchIpRoutAEntry 8 } pktSwchIpRoutFCA OBJECT-TYPE SYNTAX INTEGER { discard (1), flowControl (2), normal (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is the flow control status of this ip routing entry\connection" ::= { pktSwchIpRoutAEntry 9 } pktSwchIpRoutMetricA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "No. of hops for this route. The default value is 1. Legal values: 1 to the max no. of hops this device will support. The max no. is defined by pktSwchIpGlobalMaxHopCount." ::= { pktSwchIpRoutAEntry 10 } pktSwchIpRoutNextHopA OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "IP address of the next hop. A string of the format: X.X.X.X where every X is a number in the range 0-255." ::= { pktSwchIpRoutAEntry 11 } pktSwchIpRoutInterfaceIdA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "ID of the logical IP interface in the pktSwchIpInterface table. The IP routing module will route the IP frame according to this interface ID. Legal values: 1 to 200 and 65535. 1-200 : ID of interface. 65535 : No IP interface ID. Default value: 65535." ::= { pktSwchIpRoutAEntry 12 } -- System Priorities pktSwchPriority OBJECT IDENTIFIER ::= { pktSwchSystem 7 } -- This is a table of Tx Priorities. -- At present, it is used for DLCIs. There are 4 levels of priorities. -- Each level contains 2 parameters: max delay time and max queue length. -- This is a status which is used for saving the Tx Priority table. pktSwchTxPriorityStatus OBJECT-TYPE SYNTAX INTEGER { valid(1), underCreation(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The status of the Priorities table. Used for saving the Priority parameters. " ::= {pktSwchPriority 1} pktSwchTxPriorityTable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchTxPriorityEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Tx Priorities table." ::= {pktSwchPriority 2} pktSwchTxPriorityEntry OBJECT-TYPE SYNTAX PktSwchTxPriorityEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Tx Priority Entry defines the max delay time and max queue length for each Priority level." INDEX {pktSwchTxPriorityLevel} ::= { pktSwchTxPriorityTable 1 } PktSwchTxPriorityEntry ::= SEQUENCE { pktSwchTxPriorityLevel Integer32, pktSwchTxPriorityMaxDelayTime Integer32, pktSwchTxPriorityMaxQueueLen Integer32 } pktSwchTxPriorityLevel OBJECT-TYPE SYNTAX Integer32 (1..4) MAX-ACCESS read-only STATUS current DESCRIPTION "Level of an entry in the Tx Priority Table. At present, the PS supports 4 priority levels. Default level: 1" ::= { pktSwchTxPriorityEntry 1 } pktSwchTxPriorityMaxDelayTime OBJECT-TYPE SYNTAX Integer32 (0..60000) MAX-ACCESS read-write STATUS current DESCRIPTION "Max delay time in Tx queue (in 100 msec intervals). Each frame will wait no more than the Max delay time until it is handled. 0 means that the delay is Unlimited. Default value: 0" ::= { pktSwchTxPriorityEntry 2 } pktSwchTxPriorityMaxQueueLen OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Max allowed length of the Tx queue. Frames will be discarded if the length is exceeded. 0 means that the queue is of Unlimited length. Default value: 0" ::= { pktSwchTxPriorityEntry 3 } -- The PS Async Group contains the Profile Table, the Channel Table, -- the Call ID Table, the Alias Table, and the AsyncStat Table pktSwchAsync OBJECT IDENTIFIER ::= { radPS 2 } -- pktSwchProfile defines the (Scratch and Active) profiles that the Packet Switch devices can use to configure a channel pktSwchProfile OBJECT IDENTIFIER ::= { pktSwchAsync 1 } -- pktSwchProfileSTable defines the Scratch profiles that the Packet Switch devices can use to configure a channel pktSwchProfileSTable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchProfileSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Profile Table S defines the Scratch profiles that the PS can use to configure a channel." ::= { pktSwchProfile 1 } pktSwchProfileSEntry OBJECT-TYPE SYNTAX PktSwchProfileSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in the Profile Table S." INDEX { pktSwchProfileNumberS } ::= { pktSwchProfileSTable 1 } PktSwchProfileSEntry ::= SEQUENCE { pktSwchProfileNumberS Integer32, pktSwchProfileRecallCharS Integer32, pktSwchProfileEchoS INTEGER, pktSwchProfileDataForwCharS Integer32, pktSwchProfileIdleTimerS Integer32, pktSwchProfileDevFlowContS INTEGER, pktSwchProfileServSigS INTEGER, pktSwchProfileBreakS Integer32, pktSwchProfileDiscOutS INTEGER, pktSwchProfileCRPaddingS Integer32, pktSwchProfileLineFoldS Integer32, pktSwchProfileSpeedS INTEGER, pktSwchProfilePadFlowContS INTEGER, pktSwchProfileLineFeedInsertS INTEGER, pktSwchProfileLineFeedPadS Integer32, pktSwchProfileEditingS INTEGER, pktSwchProfileCharDelS Integer32, pktSwchProfileLineDelS Integer32, pktSwchProfileLineDispS Integer32, pktSwchProfileEditServSigS Integer32, pktSwchProfileEchomaskS Integer32, pktSwchProfileParTreatS INTEGER, pktSwchProfilePageWaitS Integer32, pktSwchProfileBitsPerCharS Integer32, pktSwchProfileDvParityS INTEGER, pktSwchProfileStopBitsS INTEGER, pktSwchProfileSpecFlowS INTEGER, pktSwchProfileCountFwdS Integer32, pktSwchProfileEscDelayS Integer32, pktSwchProfileCharBreakS Integer32, pktSwchProfileCharSuppressS Integer32, pktSwchProfileCharSubsS Integer32, pktSwchProfileFormFeedPadS Integer32, pktSwchProfileInactivityS Integer32, pktSwchProfileOptionsS Integer32, pktSwchProfileClrTimerS Integer32, pktSwchProfileSubAddInCUDS Integer32, pktSwchProfileStatusS INTEGER } pktSwchProfileNumberS OBJECT-TYPE SYNTAX Integer32 (1..200) MAX-ACCESS read-only STATUS current DESCRIPTION "The number by which a profile is identified. This is also used as the index for the profile table. The maximum profile number is 200." ::= { pktSwchProfileSEntry 1 } pktSwchProfileRecallCharS OBJECT-TYPE SYNTAX Integer32 (0..126) MAX-ACCESS read-write STATUS current DESCRIPTION "The character specified by this entry is used to escape from the data transfer mode and enter the PAD command mode. The integer values have the following meanings: (0) PAD recall is not possible (1) The PAD recall character is DLE (2) to (126) The PAD recall character is specified by the user by entering its ASCII code." ::= { pktSwchProfileSEntry 2 } pktSwchProfileEchoS OBJECT-TYPE SYNTAX INTEGER { echEn(1), noEch(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This determines if an echo of the input characters is retured to the DTE. The options are either 'echo enabled' or 'no echo'." ::= { pktSwchProfileSEntry 3 } pktSwchProfileDataForwCharS OBJECT-TYPE SYNTAX Integer32 (0..127) MAX-ACCESS read-write STATUS current DESCRIPTION "The value is a sum of values (powers of two), where each value in the sum represents a character (or characters) that is (are) used as a data forwarding character. The data forwarding characters are used to instruct the PAD to complete the assembly of and to forward a packet containing the data accumulated up to the reception of such a character. The values that may be included in the sum and their meanings are: 0 Data forwarding characters are not used 1 Alpha-numeric characters (A to Z, a to z, 0 to 9, inclusive) 2 Character CR 4 Characters ESC, BEL, ENQ, ACK 8 Characters DEL, CAN, DC2 16 Characters EOT, ETX 32 Characters HT, LF, VT, FF 64 All the other characters in colums 0 and 1 of IA5 and not listed above." ::= { pktSwchProfileSEntry 4 } pktSwchProfileIdleTimerS OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "Packets will be forwarded when the idle timer expires. The idle time interval is specified as a multiple of 50 milliseconds. The multiple is given by the parameter value. For example, a value of 60 sets an interval of 3 seconds. If the parameter value is 0, no forwarding occurs after the idle condition." ::= { pktSwchProfileSEntry 5 } pktSwchProfileDevFlowContS OBJECT-TYPE SYNTAX INTEGER { trans(1), transAndCom(2), noFlow(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter determines whether or not the PAD uses software flow control for the attached device. The options are either (1) PAD uses flow control during data transfer mode, (2) PAD uses flow control both in the data transfer mode and in the command mode, or (255) PAD does not use flow control." ::= { pktSwchProfileSEntry 6 } pktSwchProfileServSigS OBJECT-TYPE SYNTAX INTEGER { serv(1), prompt(4), servAndPrompt(5), noSig(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter is used to instruct the PAD whether to transfer PAD service signals and the PAD prompt to the local DTE in standard format. The options are (1) PAD service signals are transmitted to the DTE using the standard format, (4) The PAD prompt is transmitted using the standard format, (5) PAD service signals and the PAD prompt are transmitted in the standard format, or (255) No PAD service signals are transmitted to the DTE." ::= { pktSwchProfileSEntry 7 } pktSwchProfileBreakS OBJECT-TYPE SYNTAX Integer32 (0..31) MAX-ACCESS read-write STATUS current DESCRIPTION "The value is a sum of values (powers of two), where each value in the sum represents a PAD operation on receipt of the break signal from the DTE. The values that may be included in the sum and their meanings are: 0 Nothing 1 Send interrupt packet to network 2 Send RESET packet to network 4 Send and 'indication of break' message 8 Escape from data transfer mode 16 Discard output data waiting to be sent to the DTE ." ::= { pktSwchProfileSEntry 8 } pktSwchProfileDiscOutS OBJECT-TYPE SYNTAX INTEGER { discOut(1), normal(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter instructs the PAD whether to forward the user sequences included in data packets to the local DTE or discard them. The options are (1) discard output or (2) normal data delivery. If the value of radSPSProfileBreak is 21, the value of pktSwchProfileDiscOut is automatically set to (1) when a break signal is received." ::= { pktSwchProfileSEntry 9 } pktSwchProfileCRPaddingS OBJECT-TYPE SYNTAX Integer32 (0..127) MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter specifies the number of padding characters to be added after a carriage return character is transmitted to the local DTE." ::= { pktSwchProfileSEntry 10} pktSwchProfileLineFoldS OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter specifies the maximum number of characters to be inserted before the format effector. If the value is zero, there is no insertion of a format effector (line folding)." ::= { pktSwchProfileSEntry 11} pktSwchProfileSpeedS OBJECT-TYPE SYNTAX INTEGER { s110bps(1), s300bps(2), s1200bps(3), s600bps(4), s75bps(5), s150bps(6), s2400bps(12), s4800bps(13), s9600bps(14), s19200bps(15), s38400bps(19), s57600bps(20), s115200bps(21) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter determines the rate of data transmission to and from the DTE." ::= { pktSwchProfileSEntry 12 } pktSwchProfilePadFlowContS OBJECT-TYPE SYNTAX INTEGER { flowCont(1), noFlowCont(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This determines whether or not the terminal can exercise flow control over the PAD. The options are either 'device can exercise flow control' or 'device cannot exercise flow control." ::= { pktSwchProfileSEntry 13 } pktSwchProfileLineFeedInsertS OBJECT-TYPE SYNTAX INTEGER { afterCR(1), recCR(2), echoCR(4), onePlusFour(5), twoPlusFour(6), oneTwoFour(7), noFeed(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter indicates when there is a line feed insertion after CR. The options are (1) Insert line feed after transmission of CR to the DTE, (2) Insert line feed after receipt of CR from the DTE, (4) Insert line feed after echoing a CR character to the DTE, (5) Combination of (1) and (4), (6) Insert line feed after any CR to the DTE (combination of (2) and (4)), (7) Combination of (1), (2), and (4), or (255) No line feed insertion." ::= { pktSwchProfileSEntry 14 } pktSwchProfileLineFeedPadS OBJECT-TYPE SYNTAX Integer32 (0..127) MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter specifies the number of padding characters to be added after a line feed." ::= { pktSwchProfileSEntry 15 } pktSwchProfileEditingS OBJECT-TYPE SYNTAX INTEGER { edit(1), noEdit(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter specifies the editing capabilities available in the data transfer mode. Editing is always possible when the PAD is in the command mode. The options are (1) Command editing in the data trasfer mode is enabled or (2) No command editing in the data transfer mode." ::= { pktSwchProfileSEntry 16 } pktSwchProfileCharDelS OBJECT-TYPE SYNTAX Integer32 (0..127) MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter specifies the character delete, which is one character from IA5. The default selection is 127 (character DEL)." ::= { pktSwchProfileSEntry 17} pktSwchProfileLineDelS OBJECT-TYPE SYNTAX Integer32 (0..127) MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter specifies the line delete (last line stored in the edit buffer), which is one character from IA5. The default selection is 24 (character CAN)." ::= { pktSwchProfileSEntry 18} pktSwchProfileLineDispS OBJECT-TYPE SYNTAX Integer32 (0..127) MAX-ACCESS read-write STATUS current DESCRIPTION "This entry specifies the line display character, which is one character from IA5. The default selection is 18 (character DC2)." ::= { pktSwchProfileSEntry 19} pktSwchProfileEditServSigS OBJECT-TYPE SYNTAX Integer32 (0..126) MAX-ACCESS read-write STATUS current DESCRIPTION "This entry specifies the editing PAD service signals. The integer values have the following meanings: (0) No editing PAD service signals (1) Editing PAD service signals for printing terminals (2) Editing PAD service signals for display terminals (3) to (126) Editing PAD service signals using the desired character from IA5." ::= { pktSwchProfileSEntry 20 } pktSwchProfileEchomaskS OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "The value is a sum of values (powers of two), where each value in the sum represents a character (or characters) that is (are) included in the echo mask. The characters in the echo mask are not echoed to the DTE when PAD echo is enabled. The values that may be included in the sum and their meanings are: 0 No echo mask (all the characters are echoed) 1 No echo of character CR 2 No echo of character LF 4 No echo of characters VT, HT, FF 8 No echo of characters BEL, BS 16 No echo of characters ESC, ENQ 32 No echo of characters ACK, NAK, STX, SOH, EOT, ETB, ETX 64 No echo of the editing characters selected by radSPSProfileCharDel, radSPSProfileLineDel, and radSPSProfileLineDisp 128 No echo of the DEL character and of all the other characters in the range of ASCII 00 through 31 not mentioned above." ::= { pktSwchProfileSEntry 21 } pktSwchProfileParTreatS OBJECT-TYPE SYNTAX INTEGER { parCheck(1), parGen(2), checkAndGen(3), noPar(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This entry controls the generation of parity bits in the data sent to the local DTE and the checking of the parity bit when generated by the local DTE. The options are (1) parity checking is enabled, (2) parity generation is enabled, (3) parity checking and generation are enabled, or (255) no parity checking nor parity generation." ::= { pktSwchProfileSEntry 22 } pktSwchProfilePageWaitS OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "This entry specifies the number of line feed characters counted by the PAD before the page wait condition is entered. If the value is zero, page wait is disabled." ::= { pktSwchProfileSEntry 23} pktSwchProfileBitsPerCharS OBJECT-TYPE SYNTAX Integer32 (5..8) MAX-ACCESS read-write STATUS current DESCRIPTION "The number of data bits per character supported by the PAD." ::= { pktSwchProfileSEntry 24 } pktSwchProfileDvParityS OBJECT-TYPE SYNTAX INTEGER { space(1), mark(2), even(3), odd(4), none(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This entry selects the type of parity to be checked and or generated by the PAD when radSPSProfileParTreat is a value other than 255. The options are (1) space parity, (2) mark parity, (3) even parity, (4) odd parity, or (255) no parity." ::= { pktSwchProfileSEntry 25 } pktSwchProfileStopBitsS OBJECT-TYPE SYNTAX INTEGER { one(1), two(2), oneAndHalf(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This entry indicates the number of stop bits per character supported by the PAD. The options are either (1) one stop bit, (2) two stop bits, or (3) 1.5 stop bits." ::= { pktSwchProfileSEntry 26 } pktSwchProfileSpecFlowS OBJECT-TYPE SYNTAX INTEGER { spec(1), noSpec(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This entry is used to define additional flow control possiblilites. The options are either (1) Flow control by means of the terminal DTR line or (2) No special flow control." ::= { pktSwchProfileSEntry 27 } pktSwchProfileCountFwdS OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "This entry can be used to instruct the PAD to complete the assembly of a packet and to forward it after the specifed number of characters has been received. If the value is zero, count forwarding is disabled." ::= { pktSwchProfileSEntry 28} pktSwchProfileEscDelayS OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "This entry can be used to instruct the PAD whether to delay the forwarding of a data packet when an escape character is detected in the data stream and to determine the required delay. The packet forwarding is delayed until the specified number of characters is received after the escape character. A value of zero indicates no special handling( at the moment up to 10 chars are accepted)." ::= { pktSwchProfileSEntry 29} pktSwchProfileCharBreakS OBJECT-TYPE SYNTAX Integer32 (0..127) MAX-ACCESS read-write STATUS current DESCRIPTION "This entry specifies the decimal value of the character that will be interpreted as an additional break signal by the PAD. A value of zero indicates no break character." ::= { pktSwchProfileSEntry 30} pktSwchProfileCharSuppressS OBJECT-TYPE SYNTAX Integer32 (0..127) MAX-ACCESS read-write STATUS current DESCRIPTION "This entry specifies the decimal value of the character that will toggle echo suppression in the PAD. A value of zero indicates that echo suppression is only controlled by radSPSProfileEcho." ::= { pktSwchProfileSEntry 31} pktSwchProfileCharSubsS OBJECT-TYPE SYNTAX Integer32 (0..127) MAX-ACCESS read-write STATUS current DESCRIPTION "This entry specifies the decimal value of the character that will be echoed instead of the character received from the user's DTE. A zero value indicates that no character is echoed." ::= { pktSwchProfileSEntry 32} pktSwchProfileFormFeedPadS OBJECT-TYPE SYNTAX Integer32 (0..127) MAX-ACCESS read-write STATUS current DESCRIPTION "This entry specifies the number of padding (NUL) characters that will be automatically sent after the form feed character." ::= { pktSwchProfileSEntry 33} pktSwchProfileInactivityS OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "This entry specifies the number of minutes after which the PAD will forward the accumulated data and clear the call. A zero value indicates no disconnection on inactivity." ::= { pktSwchProfileSEntry 34 } pktSwchProfileOptionsS OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "This entry defines several options to control the profile. The value is a sum of values (powers of two), where each value in the sum represents an option . The values that may be included in the sum and their meanings are: 0 No options 1 Remote set of local X.3 parameters through X.29 is disabled 2 Add sub address to call request 4 Don't use protocol ID in user data field. 8 SPRINT NUI format 16 More bit is set when the edit buffer is full 32 Extended error message 64 Discard connect extended service signal 128 enable connect by typing the address w/out a command" ::= { pktSwchProfileSEntry 35 } pktSwchProfileClrTimerS OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "This entry specifies the number of minutes after which a call is cleared. If the parameter value is 0, there is no disconnection timer." ::= { pktSwchProfileSEntry 36 } pktSwchProfileSubAddInCUDS OBJECT-TYPE SYNTAX Integer32 (0..5) MAX-ACCESS read-write STATUS current DESCRIPTION "This entry defines the number of digits for the subaddress in CUD." ::= { pktSwchProfileSEntry 37 } pktSwchProfileStatusS OBJECT-TYPE SYNTAX INTEGER { valid(1), createRequest(2), underCreation(3), invalid(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The status of this profile. The choices are those defined in the SNMPv2 Textual Conventions for RowStatus. This will allow easy replacement of the INTEGER syntax with the RowStatus textual convention SYNTAX." ::= { pktSwchProfileSEntry 38 } -- pktSwchProfileATable defines the Active profiles that the Packet Switch devices can use to configure a channel pktSwchProfileATable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchProfileAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Profile Table defines the profiles that the PS can use to configure a channel." ::= { pktSwchProfile 2 } pktSwchProfileAEntry OBJECT-TYPE SYNTAX PktSwchProfileAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in the Profile Table." INDEX { pktSwchProfileNumberA } ::= { pktSwchProfileATable 1 } PktSwchProfileAEntry ::= SEQUENCE { pktSwchProfileNumberA Integer32, pktSwchProfileRecallCharA Integer32, pktSwchProfileEchoA INTEGER, pktSwchProfileDataForwCharA Integer32, pktSwchProfileIdleTimerA Integer32, pktSwchProfileDevFlowContA INTEGER, pktSwchProfileServSigA INTEGER, pktSwchProfileBreakA Integer32, pktSwchProfileDiscOutA INTEGER, pktSwchProfileCRPaddingA Integer32, pktSwchProfileLineFoldA Integer32, pktSwchProfileSpeedA INTEGER, pktSwchProfilePadFlowContA INTEGER, pktSwchProfileLineFeedInsertA INTEGER, pktSwchProfileLineFeedPadA Integer32, pktSwchProfileEditingA INTEGER, pktSwchProfileCharDelA Integer32, pktSwchProfileLineDelA Integer32, pktSwchProfileLineDispA Integer32, pktSwchProfileEditServSigA Integer32, pktSwchProfileEchomaskA Integer32, pktSwchProfileParTreatA INTEGER, pktSwchProfilePageWaitA Integer32, pktSwchProfileBitsPerCharA Integer32, pktSwchProfileDvParityA INTEGER, pktSwchProfileStopBitsA INTEGER, pktSwchProfileSpecFlowA INTEGER, pktSwchProfileCountFwdA Integer32, pktSwchProfileEscDelayA Integer32, pktSwchProfileCharBreakA Integer32, pktSwchProfileCharSuppressA Integer32, pktSwchProfileCharSubsA Integer32, pktSwchProfileFormFeedPadA Integer32, pktSwchProfileInactivityA Integer32, pktSwchProfileOptionsA Integer32, pktSwchProfileClrTimerA Integer32, pktSwchProfileSubAddInCUDA Integer32 } pktSwchProfileNumberA OBJECT-TYPE SYNTAX Integer32 (1..200) MAX-ACCESS read-only STATUS current DESCRIPTION "The number by which a profile is identified. This is also used as the index for the profile table. The maximum profile number is 200." ::= { pktSwchProfileAEntry 1 } pktSwchProfileRecallCharA OBJECT-TYPE SYNTAX Integer32 (0..126) MAX-ACCESS read-only STATUS current DESCRIPTION "The character specified by this entry is used to escape from the data transfer mode and enter the PAD command mode. The integer values have the following meanings: (0) PAD recall is not possible (1) The PAD recall character is DLE (2) to (126) The PAD recall character is specified by the user by entering its ASCII code." ::= { pktSwchProfileAEntry 2 } pktSwchProfileEchoA OBJECT-TYPE SYNTAX INTEGER { echEn(1), noEch(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This determines if an echo of the input characters is retured to the DTE. The options are either 'echo enabled' or 'no echo'." ::= { pktSwchProfileAEntry 3 } pktSwchProfileDataForwCharA OBJECT-TYPE SYNTAX Integer32 (0..127) MAX-ACCESS read-only STATUS current DESCRIPTION "The value is a sum of values (powers of two), where each value in the sum represents a character (or characters) that is (are) used as a data forwarding character. The data forwarding characters are used to instruct the PAD to complete the assembly of and to forward a packet containing the data accumulated up to the reception of such a character. The values that may be included in the sum and their meanings are: 0 Data forwarding characters are not used 1 Alpha-numeric characters (A to Z, a to z, 0 to 9, inclusive) 2 Character CR 4 Characters ESC, BEL, ENQ, ACK 8 Characters DEL, CAN, DC2 16 Characters EOT, ETX 32 Characters HT, LF, VT, FF 64 All the other characters in colums 0 and 1 of IA5 and not listed above." ::= { pktSwchProfileAEntry 4 } pktSwchProfileIdleTimerA OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Packets will be forwarded when the idle timer expires. The idle time interval is specified as a multiple of 50 milliseconds. The multiple is given by the parameter value. For example, a value of 60 sets an interval of 3 seconds. If the parameter value is 0, no forwarding occurs after the idle condition." ::= { pktSwchProfileAEntry 5 } pktSwchProfileDevFlowContA OBJECT-TYPE SYNTAX INTEGER { trans(1), transAndCom(2), noFlow(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter determines whether or not the PAD uses software flow control for the attached device. The options are either (1) PAD uses flow control during data transfer mode, (2) PAD uses flow control both in the data transfer mode and in the command mode, or (255) PAD does not use flow control." ::= { pktSwchProfileAEntry 6 } pktSwchProfileServSigA OBJECT-TYPE SYNTAX INTEGER { serv(1), prompt(4), servAndPrompt(5), noSig(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter is used to instruct the PAD whether to transfer PAD service signals and the PAD prompt to the local DTE in standard format. The options are (1) PAD service signals are transmitted to the DTE using the standard format, (4) The PAD prompt is transmitted using the standard format, (5) PAD service signals and the PAD prompt are transmitted in the standard format, or (255) No PAD service signals are transmitted to the DTE." ::= { pktSwchProfileAEntry 7 } pktSwchProfileBreakA OBJECT-TYPE SYNTAX Integer32 (0..31) MAX-ACCESS read-only STATUS current DESCRIPTION "The value is a sum of values (powers of two), where each value in the sum represents a PAD operation on receipt of the break signal from the DTE. The values that may be included in the sum and their meanings are: 0 Nothing 1 Send interrupt packet to network 2 Send RESET packet to network 4 Send and 'indication of break' message 8 Escape from data transfer mode 16 Discard output data waiting to be sent to the DTE ." ::= { pktSwchProfileAEntry 8 } pktSwchProfileDiscOutA OBJECT-TYPE SYNTAX INTEGER { discOut(1), normal(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter instructs the PAD whether to forward the user sequences included in data packets to the local DTE or discard them. The options are (1) discard output or (2) normal data delivery. If the value of radSPSProfileBreak is 21, the value of pktSwchProfileDiscOut is automatically set to (1) when a break signal is received." ::= { pktSwchProfileAEntry 9 } pktSwchProfileCRPaddingA OBJECT-TYPE SYNTAX Integer32 (0..127) MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter specifies the number of padding characters to be added after a carriage return character is transmitted to the local DTE." ::= { pktSwchProfileAEntry 10} pktSwchProfileLineFoldA OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter specifies the maximum number of characters to be inserted before the format effector. If the value is zero, there is no insertion of a format effector (line folding)." ::= { pktSwchProfileAEntry 11} pktSwchProfileSpeedA OBJECT-TYPE SYNTAX INTEGER { s110bps(1), s300bps(2), s1200bps(3), s600bps(4), s75bps(5), s150bps(6), s2400bps(12), s4800bps(13), s9600bps(14), s19200bps(15), s38400bps(19), s57600bps(20), s115200bps(21) } MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter determines the rate of data transmission to and from the DTE." ::= { pktSwchProfileAEntry 12 } pktSwchProfilePadFlowContA OBJECT-TYPE SYNTAX INTEGER { flowCont(1), noFlowCont(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This determines whether or not the terminal can exercise flow control over the PAD. The options are either 'device can exercise flow control' or 'device cannot exercise flow control." ::= { pktSwchProfileAEntry 13 } pktSwchProfileLineFeedInsertA OBJECT-TYPE SYNTAX INTEGER { afterCR(1), recCR(2), echoCR(4), onePlusFour(5), twoPlusFour(6), oneTwoFour(7), noFeed(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates when there is a line feed insertion after CR. The options are (1) Insert line feed after transmission of CR to the DTE, (2) Insert line feed after receipt of CR from the DTE, (4) Insert line feed after echoing a CR character to the DTE, (5) Combination of (1) and (4), (6) Insert line feed after any CR to the DTE (combination of (2) and (4)), (7) Combination of (1), (2), and (4), or (255) No line feed insertion." ::= { pktSwchProfileAEntry 14 } pktSwchProfileLineFeedPadA OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter specifies the number of padding characters to be added after a line feed." ::= { pktSwchProfileAEntry 15 } pktSwchProfileEditingA OBJECT-TYPE SYNTAX INTEGER { edit(1), noEdit(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter specifies the editing capabilities available in the data transfer mode. Editing is always possible when the PAD is in the command mode. The options are (1) Command editing in the data trasfer mode is enabled or (2) No command editing in the data transfer mode." ::= { pktSwchProfileAEntry 16 } pktSwchProfileCharDelA OBJECT-TYPE SYNTAX Integer32 (0..127) MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter specifies the character delete, which is one character from IA5. The default selection is 127 (character DEL)." ::= { pktSwchProfileAEntry 17} pktSwchProfileLineDelA OBJECT-TYPE SYNTAX Integer32 (0..127) MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter specifies the line delete, which is one character from IA5. The default selection is 24 (character CAN)." ::= { pktSwchProfileAEntry 18} pktSwchProfileLineDispA OBJECT-TYPE SYNTAX Integer32 (0..127) MAX-ACCESS read-only STATUS current DESCRIPTION "This entry specifies the line display character, which is one character from IA5. The default selection is 18 (character DC2)." ::= { pktSwchProfileAEntry 19} pktSwchProfileEditServSigA OBJECT-TYPE SYNTAX Integer32 (0..126) MAX-ACCESS read-only STATUS current DESCRIPTION "This entry specifies the editing PAD service signals. The integer values have the following meanings: (0) No editing PAD service signals (1) Editing PAD service signals for printing terminals (2) Editing PAD service signals for display terminals (3) to (126) Editing PAD service signals using the desired character from IA5." ::= { pktSwchProfileAEntry 20 } pktSwchProfileEchomaskA OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The value is a sum of values (powers of two), where each value in the sum represents a character (or characters) that is (are) included in the echo mask. The characters in the echo mask are not echoed to the DTE when PAD echo is enabled. The values that may be included in the sum and their meanings are: 0 No echo mask (all the characters are echoed) 1 No echo of character CR 2 No echo of character LF 4 No echo of characters VT, HT, FF 8 No echo of characters BEL, BS 16 No echo of characters ESC, ENQ 32 No echo of characters ACK, NAK, STX, SOH, EOT, ETB, ETX 64 No echo of the editing characters selected by radSPSProfileCharDel, radSPSProfileLineDel, and radSPSProfileLineDisp 128 No echo of the DEL character and of all the other characters in the range of ASCII 00 through 31 not mentioned above." ::= { pktSwchProfileAEntry 21 } pktSwchProfileParTreatA OBJECT-TYPE SYNTAX INTEGER { parCheck(1), parGen(2), checkAndGen(3), noPar(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This entry controls the generation of parity bits in the data sent to the local DTE and the checking of the parity bit when generated by the local DTE. The options are (1) parity checking is enabled, (2) parity generation is enabled, (3) parity checking and generation are enabled, or (255) no parity checking nor parity generation." ::= { pktSwchProfileAEntry 22 } pktSwchProfilePageWaitA OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This entry specifies the number of line feed characters counted by the PAD before the page wait condition is entered. If the value is zero, page wait is disabled." ::= { pktSwchProfileAEntry 23} pktSwchProfileBitsPerCharA OBJECT-TYPE SYNTAX Integer32 (5..8) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of data bits per character supported by the PAD." ::= { pktSwchProfileAEntry 24 } pktSwchProfileDvParityA OBJECT-TYPE SYNTAX INTEGER { space(1), mark(2), even(3), odd(4), none(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This entry selects the type of parity to be checked and or generated by the PAD when radSPSProfileParTreat is a value other than 255. The options are (1) space parity, (2) mark parity, (3) even parity, (4) odd parity, or (255) no parity." ::= { pktSwchProfileAEntry 25 } pktSwchProfileStopBitsA OBJECT-TYPE SYNTAX INTEGER { one(1), two(2), oneAndHalf(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This entry indicates the number of stop bits per character supported by the PAD. The options are either (1) one stop bit, (2) two stop bits, or (3) 1.5 stop bits." ::= { pktSwchProfileAEntry 26 } pktSwchProfileSpecFlowA OBJECT-TYPE SYNTAX INTEGER { spec(1), noSpec(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This entry is used to define additional flow control possiblilites. The options are either (1) Flow control by means fo the terminal DTR line or (2) No special flow control." ::= { pktSwchProfileAEntry 27 } pktSwchProfileCountFwdA OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This entry can be used to instruct the PAD to complete the assembly of a packet and to forward it after the specifed number of characters has been received. If the value is zero, count forwarding is disabled." ::= { pktSwchProfileAEntry 28} pktSwchProfileEscDelayA OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This entry can be used to instruct the PAD whether to delay the forwarding of a data packet when an escape character is detected in the data stream and to determine the required delay. The packet forwarding is delayed until the specified number of characters is received after the escape character. A value of zero indicates no special handling." ::= { pktSwchProfileAEntry 29} pktSwchProfileCharBreakA OBJECT-TYPE SYNTAX Integer32 (0..127) MAX-ACCESS read-only STATUS current DESCRIPTION "This entry specifies the decimal value of the character that will be interpreted as an additional break signal by the PAD. A value of zero indicates no break character." ::= { pktSwchProfileAEntry 30} pktSwchProfileCharSuppressA OBJECT-TYPE SYNTAX Integer32 (0..127) MAX-ACCESS read-only STATUS current DESCRIPTION "This entry specifies the decimal value of the character that will toggle echo suppression in the PAD. A value of zero indicates that echo suppression is only controlled by radSPSProfileEcho." ::= { pktSwchProfileAEntry 31} pktSwchProfileCharSubsA OBJECT-TYPE SYNTAX Integer32 (0..127) MAX-ACCESS read-only STATUS current DESCRIPTION "This entry specifies the decimal value of the character that will be echoed instead of the character received from the user's DTE. A zero value indicates that no character is echoed." ::= { pktSwchProfileAEntry 32} pktSwchProfileFormFeedPadA OBJECT-TYPE SYNTAX Integer32 (0..127) MAX-ACCESS read-only STATUS current DESCRIPTION "This entry specifies the number of padding (NUL) characters that will be automatically sent after the form feed character." ::= { pktSwchProfileAEntry 33} pktSwchProfileInactivityA OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This entry specifies the number of minutes after which the PAD will forward the accumulated data and clear the call. A zero value indicates no disconnection on inactivity." ::= { pktSwchProfileAEntry 34 } pktSwchProfileOptionsA OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This entry defines several options to control the profile. The value is a sum of values (powers of two), where each value in the sum represents an option . The values that may be included in the sum and their meanings are: 0 No options 1 Remote set of local X.3 parameters though X.29 is disabled 2 Add sub address to call request 4 Don't use protocol ID in user data field. 8 SPRINT NUI format 16 More bit is set when the edit buffer is full 32 Extended error message 64 Discard connect extended service signal 128 enable connect by typing the address w/out a command" ::= { pktSwchProfileAEntry 35 } pktSwchProfileClrTimerA OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This entry specifies the number of minutes after which a call is cleared. If the parameter value is 0, there is no disconnection timer." ::= { pktSwchProfileAEntry 36 } pktSwchProfileSubAddInCUDA OBJECT-TYPE SYNTAX Integer32 (0..5) MAX-ACCESS read-only STATUS current DESCRIPTION "This entry defines the number of digits for the subaddress in CUD." ::= { pktSwchProfileAEntry 37 } -- pktSwchChannel (Scratch and Active) defines the channel configurations -- of all the channels on the PS pktSwchChannel OBJECT IDENTIFIER ::= { pktSwchAsync 2 } -- pktSwchChannelSTable defines the Scratch channel configurations of all -- the channels on the PS pktSwchChannelSTable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchChannelSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Scratch Channel Table defines the channels configured on the PS." ::= { pktSwchChannel 1 } pktSwchChannelSEntry OBJECT-TYPE SYNTAX PktSwchChannelSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in the Scratch Channel Table." INDEX { pktSwchChannelIfIndexS } ::= { pktSwchChannelSTable 1 } PktSwchChannelSEntry ::= SEQUENCE { pktSwchChannelIfIndexS Integer32, pktSwchChannelNumberS Integer32, pktSwchChannelProfileS Integer32, pktSwchChannelOutCallProfileS Integer32, pktSwchChannelInCallProfileS Integer32, pktSwchChannelRemoteProfileS Integer32, pktSwchChannelAutocallIdS Integer32, pktSwchChannelAlterAutocallIdS Integer32, pktSwchChannelAutocallRetriesS Integer32, pktSwchChannelAutocallIntervalS Integer32, pktSwchChannelCallAliasS Integer32, pktSwchChannelSubAddress1S Integer32, pktSwchChannelSubAddress2S Integer32, pktSwchChannelNUISEntry Integer32, pktSwchChannelClearTimerS Integer32, pktSwchChannelOptionsS Integer32, pktSwchChannelClear INTEGER, pktSwchChannelCopyTo Integer32, pktSwchChannelCopyToWMask Integer32, pktSwchChannelCopyMask Integer32 } pktSwchChannelIfIndexS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is used as the index for the channel table." ::= { pktSwchChannelSEntry 1 } pktSwchChannelNumberS OBJECT-TYPE SYNTAX Integer32 (1..1224) MAX-ACCESS read-only STATUS current DESCRIPTION "The number by which a channel is identified." ::= { pktSwchChannelSEntry 2 } pktSwchChannelProfileS OBJECT-TYPE SYNTAX Integer32 (1..200) MAX-ACCESS read-write STATUS current DESCRIPTION "The profile that the channel uses for command mode operations." ::= { pktSwchChannelSEntry 3 } pktSwchChannelOutCallProfileS OBJECT-TYPE SYNTAX Integer32 (0..200) MAX-ACCESS read-write STATUS current DESCRIPTION "The number of the profile that will be used during an outgoing call on the channel." ::= { pktSwchChannelSEntry 4 } pktSwchChannelInCallProfileS OBJECT-TYPE SYNTAX Integer32 (0..200) MAX-ACCESS read-write STATUS current DESCRIPTION "The number of the profile that will be used during an incoming call on the channel." ::= { pktSwchChannelSEntry 5 } pktSwchChannelRemoteProfileS OBJECT-TYPE SYNTAX Integer32 (0..200) MAX-ACCESS read-write STATUS current DESCRIPTION "The number of the profile that will be downloaded to the remote PAD at the beginning of a new call." ::= { pktSwchChannelSEntry 6 } pktSwchChannelAutocallIdS OBJECT-TYPE SYNTAX Integer32 (0..200) MAX-ACCESS read-write STATUS current DESCRIPTION "Selects the mnemonic (call ID) to be used as the first alternative. A value of zero indicates that the autocall function is disabled." ::= { pktSwchChannelSEntry 7 } pktSwchChannelAlterAutocallIdS OBJECT-TYPE SYNTAX Integer32 (0..200) MAX-ACCESS read-write STATUS current DESCRIPTION "Selects the alternate mnemonic for the autocall function. A value of zero indicates that the alternate destination is not used." ::= { pktSwchChannelSEntry 8 } pktSwchChannelAutocallRetriesS OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "The number of autocall retries if the autocall setup request is rejected with a busy cause." ::= { pktSwchChannelSEntry 9 } pktSwchChannelAutocallIntervalS OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "The interval in seconds between consecutive autocall retries." ::= { pktSwchChannelSEntry 10 } pktSwchChannelCallAliasS OBJECT-TYPE SYNTAX Integer32 (0..200) MAX-ACCESS read-write STATUS current DESCRIPTION "The alias to be sent after the call is set up. A value of zero indicates that alias sending is disabled. The aliases are configured on the Alias Table." ::= { pktSwchChannelSEntry 11 } pktSwchChannelSubAddress1S OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "The first subaddress for the channel." ::= { pktSwchChannelSEntry 12 } pktSwchChannelSubAddress2S OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "The second subaddress for the channel." ::= { pktSwchChannelSEntry 13} pktSwchChannelNUISEntry OBJECT-TYPE SYNTAX Integer32 (1..200) MAX-ACCESS read-write STATUS current DESCRIPTION "The number corresponding to the NUI information to be sent. This number is the same as the pktSwchNuiGroupId." ::= { pktSwchChannelSEntry 14 } pktSwchChannelClearTimerS OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "Time limitation for an open session. A value of zero indicates that the Clear timer is not used." ::= { pktSwchChannelSEntry 15 } pktSwchChannelOptionsS OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "This controls the use of gneral non-correlated channel options. The value is a sum of values (powers of two), where each value in the sum represents an option. The values that may be included in the sum and their meanings are: 0 No options 1 HW signal is checked 2 Auto call after clear 4 Auto call after 8 DCD is ON, only in DATA TRANSFER mode 16 Charging Info Facility 32 Auto call if HW signal is set 64 Accept calls even if HW signal is is OFF 128 A transparent channel." ::= { pktSwchChannelSEntry 16 } pktSwchChannelClear OBJECT-TYPE SYNTAX INTEGER { noOp(1), clear(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The Clearing Channel operation disconnects all sessions" ::= { pktSwchChannelSEntry 17 } pktSwchChannelCopyTo OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The destination channel number, to which the Copy is performed." ::= { pktSwchChannelSEntry 18 } pktSwchChannelCopyToWMask OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The destination channel number, to which the Copy with Mask is performed." ::= { pktSwchChannelSEntry 19 } pktSwchChannelCopyMask OBJECT-TYPE SYNTAX Integer32 (0..16383) MAX-ACCESS read-write STATUS current DESCRIPTION "The selected configuration parameters to be copied from the source channel to the target channels. The value is a sum of values (powers of two), where each value in the sum represents a selected parameter that is not copied. The values that may be included in the sum and their meanings are: 0 Copy all. 1 Do not copy Profile. 2 Do not copy OutCallProfile. 4 Do not copy InCallProfile. 8 Do not copy RemoteProfile. 16 Do not copy AutocallId. 32 Do not copy AlterCallId. 64 Do not copy AutoCallRetries. 128 Do not copy AutoCallInterval. 256 Do not copy CallAlias. 512 Do not copy SubAddress1. 1024 Do not copy SubAddress2. 2048 Do not copy NUIEntry. 4096 Do not copy ClearTimer. 8192 Do not copy Options. XXX - Any combination of the above." ::= { pktSwchChannelSEntry 20 } pktSwchChannelATable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchChannelAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Active Channel Table defines the channels configured on the PS." ::= { pktSwchChannel 2 } pktSwchChannelAEntry OBJECT-TYPE SYNTAX PktSwchChannelAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in the Active Channel Table." INDEX { pktSwchChannelIfIndexA } ::= { pktSwchChannelATable 1 } PktSwchChannelAEntry ::= SEQUENCE { pktSwchChannelIfIndexA Integer32, pktSwchChannelNumberA Integer32, pktSwchChannelProfileA Integer32, pktSwchChannelOutCallProfileA Integer32, pktSwchChannelInCallProfileA Integer32, pktSwchChannelRemoteProfileA Integer32, pktSwchChannelAutocallIdA Integer32, pktSwchChannelAlterAutocallIdA Integer32, pktSwchChannelAutocallRetriesA Integer32, pktSwchChannelAutocallIntervalA Integer32, pktSwchChannelCallAliasA Integer32, pktSwchChannelSubAddress1A Integer32, pktSwchChannelSubAddress2A Integer32, pktSwchChannelNUIAEntry Integer32, pktSwchChannelClearTimerA Integer32, pktSwchChannelOptionsA Integer32 } pktSwchChannelIfIndexA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is used as the index for the channel table." ::= { pktSwchChannelAEntry 1 } pktSwchChannelNumberA OBJECT-TYPE SYNTAX Integer32 (1..288) MAX-ACCESS read-only STATUS current DESCRIPTION "The number by which a channel is identified." ::= { pktSwchChannelAEntry 2 } pktSwchChannelProfileA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The profile that the channel uses for command mode operations." ::= { pktSwchChannelAEntry 3 } pktSwchChannelOutCallProfileA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of the profile that is used during an outgoing call on the channel." ::= { pktSwchChannelAEntry 4 } pktSwchChannelInCallProfileA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of the profile that is used during an incoming call on the channel." ::= { pktSwchChannelAEntry 5 } pktSwchChannelRemoteProfileA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of the profile that is downloaded to the remote PAD at the beginning of a new call." ::= { pktSwchChannelAEntry 6 } pktSwchChannelAutocallIdA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Selects the mnemonic (call ID) to be used as the first alternative. A value of zero indicates that the autocall function is disabled." ::= { pktSwchChannelAEntry 7 } pktSwchChannelAlterAutocallIdA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Selects the alternate mnemonic for the autocall function. A value of zero indicates that the alternate destination is not used." ::= { pktSwchChannelAEntry 8 } pktSwchChannelAutocallRetriesA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of autocall retrues if the autocall setup request is rejected with a busy cause." ::= { pktSwchChannelAEntry 9 } pktSwchChannelAutocallIntervalA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The interval in seconds between consecutive autocall retries." ::= { pktSwchChannelAEntry 10 } pktSwchChannelCallAliasA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The alias to be sent after the call is set up. A value of zero indicates that alias sending is disabled. The aliases are configured on the Alias Table." ::= { pktSwchChannelAEntry 11 } pktSwchChannelSubAddress1A OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The first subaddress for the channel." ::= { pktSwchChannelAEntry 12 } pktSwchChannelSubAddress2A OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The second subaddress for the channel." ::= { pktSwchChannelAEntry 13} pktSwchChannelNUIAEntry OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number corresponding to the NUI information to be sent. This number is the same as the pktSwchNuiIndex." ::= { pktSwchChannelAEntry 14 } pktSwchChannelClearTimerA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Time limitation for an open session. A value of zero indicates that the Clear timer is not used." ::= { pktSwchChannelAEntry 15 } pktSwchChannelOptionsA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This controls the use of general non-correlated channel options. The value is a sum of values (powers of two), where each value in the sum represents an option. The values that may be included in the sum and their meanings are: 0 No options 1 RTS line checked 2 Auto call after clear 4 Auto call after 8 DCD is ON, only in DATA TRANSFER mode. 16 Charging Info Facility 32 Auto call if HW signal is set 64 Accept calls even if HW signal is is OFF 128 A transparent channel." ::= { pktSwchChannelAEntry 16 } -- pktSwchCallId defines the Call IDs pktSwchCallId OBJECT IDENTIFIER ::= { pktSwchAsync 3 } -- pktSwchCallIdSTable defines the Scratch Call IDs pktSwchCallIdSTable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchCallIdSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Call ID Table S defines the Scratch Call IDs configured on the device." ::= { pktSwchCallId 1 } pktSwchCallIdSEntry OBJECT-TYPE SYNTAX PktSwchCallIdSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in the Scratch CallId Table." INDEX { pktSwchCallIdNumberS } ::= { pktSwchCallIdSTable 1 } PktSwchCallIdSEntry ::= SEQUENCE { pktSwchCallIdNumberS Integer32, pktSwchCallIdMnemonicS DisplayString, pktSwchCallIdAddressS DisplayString, pktSwchCallIdStatusS INTEGER } pktSwchCallIdNumberS OBJECT-TYPE SYNTAX Integer32 (1..200) MAX-ACCESS read-write STATUS current DESCRIPTION "The index of this entry." ::= { pktSwchCallIdSEntry 1 } pktSwchCallIdMnemonicS OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The mnemonic for this call ID." ::= { pktSwchCallIdSEntry 2 } pktSwchCallIdAddressS OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The address for this call ID." ::= { pktSwchCallIdSEntry 3 } pktSwchCallIdStatusS OBJECT-TYPE SYNTAX INTEGER { valid(1), createRequest(2), underCreation(3), invalid(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The status of this Call ID table entry. The choices are those defined in the SNMPv2 Textual Conventions for RowStatus. This will allow easy replacement of the INTEGER syntax with the RowStatus textual convention SYNTAX." ::= { pktSwchCallIdSEntry 4 } -- pktSwchCallIdATable defines the Active Call IDs pktSwchCallIdATable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchCallIdAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Call ID Table A defines the Active Call IDs configured on the device." ::= { pktSwchCallId 2 } pktSwchCallIdAEntry OBJECT-TYPE SYNTAX PktSwchCallIdAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in the Active CallId Table." INDEX { pktSwchCallIdNumberA } ::= { pktSwchCallIdATable 1 } PktSwchCallIdAEntry ::= SEQUENCE { pktSwchCallIdNumberA Integer32, pktSwchCallIdMnemonicA DisplayString, pktSwchCallIdAddressA DisplayString } pktSwchCallIdNumberA OBJECT-TYPE SYNTAX Integer32 (1..200) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of this entry." ::= { pktSwchCallIdAEntry 1 } pktSwchCallIdMnemonicA OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The mnemonic for this call ID." ::= { pktSwchCallIdAEntry 2 } pktSwchCallIdAddressA OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The address for this call ID." ::= { pktSwchCallIdAEntry 3 } -- pktSwchAlias defines the Aliases pktSwchAlias OBJECT IDENTIFIER ::= { pktSwchAsync 4 } -- pktSwchAliasSTable defines the Scratch Aliases pktSwchAliasSTable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchAliasSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Alias Table defines the aliases configured on the device." ::= { pktSwchAlias 1 } pktSwchAliasSEntry OBJECT-TYPE SYNTAX PktSwchAliasSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in the Alias Table." INDEX { pktSwchAliasNumberS } ::= { pktSwchAliasSTable 1 } PktSwchAliasSEntry ::= SEQUENCE { pktSwchAliasNumberS Integer32, pktSwchAliasValueS DisplayString, pktSwchAliasStatusS INTEGER } pktSwchAliasNumberS OBJECT-TYPE SYNTAX Integer32 (1..200) MAX-ACCESS read-write STATUS current DESCRIPTION "The index of this entry." ::= { pktSwchAliasSEntry 1 } pktSwchAliasValueS OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "The alias is defined using up to 64 characters." ::= { pktSwchAliasSEntry 2 } pktSwchAliasStatusS OBJECT-TYPE SYNTAX INTEGER { valid(1), createRequest(2), underCreation(3), invalid(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The status of this Alias table entry. The choices are those defined in the SNMPv2 Textual Conventions for RowStatus. This will allow easy replacement of the INTEGER syntax with the RowStatus textual convention SYNTAX." ::= { pktSwchAliasSEntry 3 } -- pktSwchAliasATable defines the Active Aliases pktSwchAliasATable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchAliasAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Alias Table defines the aliases configured on the device." ::= { pktSwchAlias 2 } pktSwchAliasAEntry OBJECT-TYPE SYNTAX PktSwchAliasAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in the Alias Table." INDEX { pktSwchAliasNumberA } ::= { pktSwchAliasATable 1 } PktSwchAliasAEntry ::= SEQUENCE { pktSwchAliasNumberA Integer32, pktSwchAliasValueA DisplayString } pktSwchAliasNumberA OBJECT-TYPE SYNTAX Integer32 (1..200) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of this entry." ::= { pktSwchAliasAEntry 1 } pktSwchAliasValueA OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "The alias is defined using up to 64 characters." ::= { pktSwchAliasAEntry 2 } -- The pktSwchAsyncStatTable contains status information and statistics -- for the Async channels pktSwchAsyncStatTable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchAsyncStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The AsyncStat Table includes status information and statistics provided by the PS on the async channels." ::= { pktSwchAsync 5 } pktSwchAsyncStatEntry OBJECT-TYPE SYNTAX PktSwchAsyncStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in the Async Stat Table." INDEX { pktSwchAsyncIfIndex } ::= { pktSwchAsyncStatTable 1 } PktSwchAsyncStatEntry ::= SEQUENCE { pktSwchAsyncIfIndex Integer32, pktSwchAsyncChannelNumber Integer32, pktSwchAsyncConnectionStatus INTEGER, pktSwchAsyncNumLogChannels Integer32, pktSwchAsyncNumActSessions Integer32, pktSwchAsyncAutocallId Integer32, pktSwchAsyncRTSStatus INTEGER, pktSwchAsyncBuffToNet Integer32, pktSwchAsyncBuffToUser Integer32, pktSwchAsyncTxXoff INTEGER, pktSwchAsyncRxXoff INTEGER, pktSwchAsyncBuffOutstand Integer32, pktSwchAsyncChannelMode INTEGER } pktSwchAsyncIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "An index for the table." ::= { pktSwchAsyncStatEntry 1 } pktSwchAsyncChannelNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The channel to which this entry applies. This value is the same as the pktSwchChannelNumber." ::= { pktSwchAsyncStatEntry 2 } pktSwchAsyncConnectionStatus OBJECT-TYPE SYNTAX INTEGER { engaged(1), free (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the channel is either FREE or ENG (engaged)." ::= { pktSwchAsyncStatEntry 3} pktSwchAsyncNumLogChannels OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of active logical channels used by the asynchronous channel." ::= { pktSwchAsyncStatEntry 4 } pktSwchAsyncNumActSessions OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of active sessions opened by this asynchronous channel." ::= { pktSwchAsyncStatEntry 5 } pktSwchAsyncAutocallId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the channel has been configured to use the autocall function and what is the call ID. NONE means that the channel is not configured for autocall." ::= { pktSwchAsyncStatEntry 6} pktSwchAsyncRTSStatus OBJECT-TYPE SYNTAX INTEGER { unused(1), off (2), on (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Shows the status of the RTS line of the asynchronous channel. OFF indicates that the RTS line is not active, ON indicates that it is active, and UNUSED indicates that the channel PAD is programmed to disregard the state of the RTS line." ::= { pktSwchAsyncStatEntry 7 } pktSwchAsyncBuffToNet OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of data buffers currently used by the transmit direction of the channel." ::= { pktSwchAsyncStatEntry 8 } pktSwchAsyncBuffToUser OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of data buffers currently used by the receive direction of the channel." ::= { pktSwchAsyncStatEntry 9} pktSwchAsyncTxXoff OBJECT-TYPE SYNTAX INTEGER { no (1), yes(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current state of software flow control in the transmit direction. NO indicates that traffic flow is enabled. YES indicates that traffic flow from the user's DTE to the device channel has been interrupted by sending the X-OFF character to the DTE." ::= { pktSwchAsyncStatEntry 10 } pktSwchAsyncRxXoff OBJECT-TYPE SYNTAX INTEGER { no (1), yes(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current state of software flow control in the receive direction. NO indicates that traffic flow is enabled. YES indicates that traffic flow to the user's DTE from the device channel has been interrupted by means of the X-OFF character." ::= { pktSwchAsyncStatEntry 11 } pktSwchAsyncBuffOutstand OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the number of buffers which were sent to the async user but weren't yet freed." ::= { pktSwchAsyncStatEntry 12 } pktSwchAsyncChannelMode OBJECT-TYPE SYNTAX INTEGER { none (1), activeLink (2), x28command (3), dataTransfer(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The channel mode is either X28 COMMAND or DATA TRANSFER." ::= { pktSwchAsyncStatEntry 13 } -- The pktSwchAsyncRunProTable contains status information and statistics for the Async channels pktSwchAsyncRunProTable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchAsyncRunProEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The AsyncRunPro Table includes status information and statistics provided by the PS on the async channels." ::= { pktSwchAsync 6 } pktSwchAsyncRunProEntry OBJECT-TYPE SYNTAX PktSwchAsyncRunProEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in the Async RunPro Table." INDEX { pktSwchAsyncRunProIfIndex } ::= { pktSwchAsyncRunProTable 1 } PktSwchAsyncRunProEntry ::= SEQUENCE { pktSwchAsyncRunProIfIndex Integer32, pktSwchAsyncRunProChannelNumber Integer32, pktSwchAsyncRunProRecallChar Integer32, pktSwchAsyncRunProEcho INTEGER, pktSwchAsyncRunProDataForwChar Integer32, pktSwchAsyncRunProIdleTimer Integer32, pktSwchAsyncRunProDevFlowCont INTEGER, pktSwchAsyncRunProServSig INTEGER, pktSwchAsyncRunProBreak Integer32, pktSwchAsyncRunProDiscOut INTEGER, pktSwchAsyncRunProCRPPadding Integer32, pktSwchAsyncRunProLineFold Integer32, pktSwchAsyncRunProSpeed INTEGER, pktSwchAsyncRunProPadFlowCont INTEGER, pktSwchAsyncRunProLineFeedInsert INTEGER, pktSwchAsyncRunProLineFeedPad Integer32, pktSwchAsyncRunProEditing INTEGER, pktSwchAsyncRunProCharDel Integer32, pktSwchAsyncRunProLineDel Integer32, pktSwchAsyncRunProLineDisp Integer32, pktSwchAsyncRunProEditServSig Integer32, pktSwchAsyncRunProEchomask Integer32, pktSwchAsyncRunProParTreat INTEGER, pktSwchAsyncRunProPageWait Integer32 } pktSwchAsyncRunProIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "An index for the table." ::= { pktSwchAsyncRunProEntry 1 } pktSwchAsyncRunProChannelNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The channel to which this entry applies. This value is the same as the pktSwchChannelNumber." ::= { pktSwchAsyncRunProEntry 2 } pktSwchAsyncRunProRecallChar OBJECT-TYPE SYNTAX Integer32 (0..126) MAX-ACCESS read-only STATUS current DESCRIPTION "The character specified by this entry is used to escape from the data transfer mode and enter the PAD command mode. The integer values have the following meanings: (0) PAD recall is not possible (1) The PAD recall character is DLE (2) to (126) The PAD recall character is specified by the user by entering its ASCII code." ::= { pktSwchAsyncRunProEntry 3 } pktSwchAsyncRunProEcho OBJECT-TYPE SYNTAX INTEGER { echEn(1), noEch(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This determines if an echo of the input characters is retured to the DTE. The options are either 'echo enabled' or 'no echo'." ::= { pktSwchAsyncRunProEntry 4 } pktSwchAsyncRunProDataForwChar OBJECT-TYPE SYNTAX Integer32 (0..127) MAX-ACCESS read-only STATUS current DESCRIPTION "The value is a sum of values (powers of two), where each value in the sum represents a character (or characters) that is (are) used as a data forwarding character. The data forwarding characters are used to instruct the PAD to complete the assembly of and to forward a packet containing the data accumulated up to the reception of such a character. The values that may be included in the sum and their meanings are: 0 Data forwarding characters are not used 1 Alpha-numeric characters (A to Z, a to z, 0 to 9, inclusive) 2 Character CR 4 Characters ESC, BEL, ENQ, ACK 8 Characters DEL, CAN, DC2 16 Characters EOT, ETX 32 Characters HT, LF, VT, FF 64 All the other characters in colums 0 and 1 of IA5 and not listed above." ::= { pktSwchAsyncRunProEntry 5 } pktSwchAsyncRunProIdleTimer OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Packets will be forwarded when the idle timer expires. The idle time interval is specified as a multiple of 50 milliseconds. The multiple is given by the parameter value. For example, a value of 60 sets an interval of 3 seconds. If the parameter value is 0, no forwarding occurs after the idle condition." ::= { pktSwchAsyncRunProEntry 6 } pktSwchAsyncRunProDevFlowCont OBJECT-TYPE SYNTAX INTEGER { trans(1), transAndCom(2), noFlow(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter determines whether or not the PAD uses software flow control for the attached device. The options are either (1) PAD uses flow control during data transfer mode, (2) PAD uses flow control both in the data transfer mode and in the command mode, or (255) PAD does not use flow control." ::= { pktSwchAsyncRunProEntry 7 } pktSwchAsyncRunProServSig OBJECT-TYPE SYNTAX INTEGER { serv(1), prompt(4), servAndPrompt(5), noSig(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter is used to instruct the PAD whether to transfer PAD service signals and the PAD prompt to the local DTE in standard format. The options are (1) PAD service signals are transmitted to the DTE using the standard format, (4) The PAD prompt is transmitted using the standard format, (5) PAD service signals and the PAD prompt are transmitted in the standard format, or (255) No PAD service signals are transmitted to the DTE." ::= { pktSwchAsyncRunProEntry 8 } pktSwchAsyncRunProBreak OBJECT-TYPE SYNTAX Integer32 (0..31) MAX-ACCESS read-only STATUS current DESCRIPTION "The value is a sum of values (powers of two), where each value in the sum represents a PAD operation on receipt of the break signal from the DTE. The values that may be included in the sum and their meanings are: 0 Nothing 1 Send interrupt packet to network 2 Send RESET packet to network 4 Send and 'indication of break' message 8 Escape from data transfer mode 16 Discard output data waiting to be sent to the DTE ." ::= { pktSwchAsyncRunProEntry 9 } pktSwchAsyncRunProDiscOut OBJECT-TYPE SYNTAX INTEGER { discOut(1), normal(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter instructs the PAD whether to forward the user sequences included in data packets to the local DTE or discard them. The options are (1) discard output or (2) normal data delivery. If the value of radSPSProfileBreak is 21, the value of pktSwchAsyncRunProDiscOut is automatically set to (1) when a break signal is received." ::= { pktSwchAsyncRunProEntry 10 } pktSwchAsyncRunProCRPPadding OBJECT-TYPE SYNTAX Integer32 (0..127) MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter specifies the number of padding characters to be added after a carriage return character is transmitted to the local DTE." ::= { pktSwchAsyncRunProEntry 11} pktSwchAsyncRunProLineFold OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter specifies the maximum number of characters to be inserted before the format effector. If the value is zero, there is no insertion of a format effector (line folding)." ::= { pktSwchAsyncRunProEntry 12} pktSwchAsyncRunProSpeed OBJECT-TYPE SYNTAX INTEGER { s110bps(1), s300bps(2), s1200bps(3), s600bps(4), s75bps(5), s150bps(6), s2400bps(12), s4800bps(13), s9600bps(14), s19200bps(15), s38400bps(19), s57600bps(20), s115200bps(21) } MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter determines the rate of data transmission to and from the DTE." ::= { pktSwchAsyncRunProEntry 13 } pktSwchAsyncRunProPadFlowCont OBJECT-TYPE SYNTAX INTEGER { flowCont(1), noFlowCont(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This determines whether or not the terminal can exercise flow control over the PAD. The options are either 'device can exercise flow control' or 'device cannot exercise flow control." ::= { pktSwchAsyncRunProEntry 14 } pktSwchAsyncRunProLineFeedInsert OBJECT-TYPE SYNTAX INTEGER { afterCR(1), recCR(2), echoCR(4), onePlusFour(5), twoPlusFour(6), oneTwoFour(7), noFeed(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates when there is a line feed insertion after CR. The options are (1) Insert line feed after transmission of CR to the DTE, (2) Insert line feed after receipt of CR from the DTE, (4) Insert line feed after echoing a CR character to the DTE, (5) Combination of (1) and (4), (6) Insert line feed after any CR to the DTE (combination of (2) and (4)), (7) Combination of (1), (2), and (4), or (255) No line feed insertion." ::= { pktSwchAsyncRunProEntry 15 } pktSwchAsyncRunProLineFeedPad OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter specifies the number of padding characters to be added after a line feed." ::= { pktSwchAsyncRunProEntry 16 } pktSwchAsyncRunProEditing OBJECT-TYPE SYNTAX INTEGER { edit(1), noEdit(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter specifies the editing capabilities available in the data transfer mode. Editing is always possible when the PAD is in the command mode. The options are (1) Command editing in the data trasfer mode is enabled or (2) No command editing in the data transfer mode." ::= { pktSwchAsyncRunProEntry 17 } pktSwchAsyncRunProCharDel OBJECT-TYPE SYNTAX Integer32 (0..127) MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter specifies the character delete, which is one character from IA5. The default selection is 127 (character DEL)." ::= { pktSwchAsyncRunProEntry 18} pktSwchAsyncRunProLineDel OBJECT-TYPE SYNTAX Integer32 (0..127) MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter specifies the line delete, which is one character from IA5. The default selection is 24 (character CAN)." ::= { pktSwchAsyncRunProEntry 19} pktSwchAsyncRunProLineDisp OBJECT-TYPE SYNTAX Integer32 (0..127) MAX-ACCESS read-only STATUS current DESCRIPTION "This entry specifies the line display character, which is one character from IA5. The default selection is 18 (character DC2)." ::= { pktSwchAsyncRunProEntry 20} pktSwchAsyncRunProEditServSig OBJECT-TYPE SYNTAX Integer32 (0..126) MAX-ACCESS read-only STATUS current DESCRIPTION "This entry specifies the editing PAD service signals. The integer values have the following meanings: (0) No editing PAD service signals (1) Editing PAD service signals for printing terminals (2) Editing PAD service signals for display terminals (3) to (126) Editing PAD service signals using the desired character from IA5." ::= { pktSwchAsyncRunProEntry 21 } pktSwchAsyncRunProEchomask OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The value is a sum of values (powers of two), where each value in the sum represents a character (or characters) that is (are) included in the echo mask. The characters in the echo mask are not echoed to the DTE when PAD echo is enabled. The values that may be included in the sum and their meanings are: 0 No echo mask (all the characters are echoed) 1 No echo of character CR 2 No echo of character LF 4 No echo of characters VT, HT, FF 8 No echo of characters BEL, BS 16 No echo of characters ESC, ENQ 32 No echo of characters ACK, NAK, STX, SOH, EOT, ETB, ETX 64 No echo of the editing characters selected by radSPSProfileCharDel, radSPSProfileLineDel, and radSPSProfileLineDisp 128 No echo of the DEL character and of all the other characters in the range of ASCII 00 through 31 not mentioned above." ::= { pktSwchAsyncRunProEntry 22 } pktSwchAsyncRunProParTreat OBJECT-TYPE SYNTAX INTEGER { parCheck(1), parGen(2), checkAndGen(3), noPar(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This entry controls the generation of parity bits in the data sent to the local DTE and the checking of the parity bit when generated by the local DTE. The options are (1) parity checking is enabled, (2) parity generation is enabled, (3) parity checking and generation are enabled, or (255) no parity checking nor parity generation." ::= { pktSwchAsyncRunProEntry 23 } pktSwchAsyncRunProPageWait OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This entry specifies the number of line feed characters counted by the PAD before the page wait condition is entered. If the value is zero, page wait is disabled." ::= { pktSwchAsyncRunProEntry 24} -- pktSwch defines the scratch and active PhyInterface configurations of -- the PS pktSwchPhyInterfaceTable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchPhyInterfaceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Link Table defines the links configured on the PS." ::= { radPS 3 } pktSwchPhyInterfaceEntry OBJECT-TYPE SYNTAX PktSwchPhyInterfaceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in the Link Table." INDEX { pktSwchPhyInterfaceIfIndex } ::= { pktSwchPhyInterfaceTable 1 } PktSwchPhyInterfaceEntry ::= SEQUENCE { pktSwchPhyInterfaceIfIndex Integer32, pktSwchPhyInterfaceProtocolS INTEGER, pktSwchPhyInterfaceProtocolA INTEGER, pktSwchPhyInterfaceCopyTo Integer32, pktSwchPhyInterfaceChanged INTEGER, pktSwchPhyInterfaceRxBuffInPool Integer32, pktSwchPhyInterfaceConnector INTEGER, pktSwchPhyInterfaceNeighborIp IpAddress, pktSwchPhyInterfaceProtocolStatus INTEGER, pktSwchPhyInterfaceTestCmd INTEGER, pktSwchPhyInterfaceTestTransmittedFrames Counter32, pktSwchPhyInterfaceTestReceivedFrames Counter32, pktSwchPhyInterfaceTestLostFrames Integer32 } pktSwchPhyInterfaceIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The ifIndex identified with this link." ::= { pktSwchPhyInterfaceEntry 1 } pktSwchPhyInterfaceProtocolS OBJECT-TYPE SYNTAX INTEGER { x25(1), frameRelay(2), hdlc(3), sdlc(4), async(5), stm4(6), stm8(7), stm16(8), stm24(9), mpe(10), bscHpad(11), bscTpad(12), slip(13), ethernet(14), ppp(15) } MAX-ACCESS read-write STATUS current DESCRIPTION "The protocol to be used on this link. Note for PPP: PPP protocol is allowed to be applied on Sync Links (1-3) as well as Async channels (1-24). In order to eliminate ambiguity in the IP destination where a destination of P1 can be used for example for async channel 1 and Sync Link 1, it was decided NOT TO ALLOW configuring PPP on both Sync Link no. 1 and async channel 1. Same for Link 2 and Link 3." ::= { pktSwchPhyInterfaceEntry 2 } pktSwchPhyInterfaceProtocolA OBJECT-TYPE SYNTAX INTEGER { x25(1), frameRelay(2), hdlc(3), sdlc(4), async(5), stm4(6), stm8(7), stm16(8), stm24(9), mpe(10), bscHpad(11), bscTpad(12), slip(13), ethernet(14), ppp(15) } MAX-ACCESS read-only STATUS current DESCRIPTION "The protocol currently used on this link." ::= { pktSwchPhyInterfaceEntry 3 } pktSwchPhyInterfaceCopyTo OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The destination interface number, to which the Copy is performed." ::= { pktSwchPhyInterfaceEntry 4 } pktSwchPhyInterfaceChanged OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates if the current running protocol is different than the defined protocol" ::= { pktSwchPhyInterfaceEntry 5 } pktSwchPhyInterfaceRxBuffInPool OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The free data buffers in the Rx pool per interface" ::= { pktSwchPhyInterfaceEntry 6 } pktSwchPhyInterfaceConnector OBJECT-TYPE SYNTAX INTEGER { v24(2), v35(3), x21(4), rs530(5), acd(6), mobi(7), u(8), etherUtp(9), noConnector(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "The connector type of the interface" ::= { pktSwchPhyInterfaceEntry 7 } pktSwchPhyInterfaceNeighborIp OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The Ip address of the device on the other side of the link." ::= { pktSwchPhyInterfaceEntry 8 } pktSwchPhyInterfaceProtocolStatus OBJECT-TYPE SYNTAX INTEGER { valid(1), createRequest(2), underCreation(3), invalid(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The status of the Interface Protocol row in the Table." ::= { pktSwchPhyInterfaceEntry 9 } pktSwchPhyInterfaceTestCmd OBJECT-TYPE SYNTAX INTEGER { noOp (1), v54Local (2), v54Remote(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "START/STOP a test on the current interface. The available tests are: v54Local - Local Analog Loopback (AL), L3 according to ITU-T standard. v54Remote - Remote Digital Loopback(RDL), L2 according to ITU-T standard. For stopping the test, SET the noOp (1) option. " ::= { pktSwchPhyInterfaceEntry 10 } pktSwchPhyInterfaceTestTransmittedFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "No. of frames which were transmitted from this interface during the TEST." ::= { pktSwchPhyInterfaceEntry 11 } pktSwchPhyInterfaceTestReceivedFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "No. of frames which were received on this interface during the TEST." ::= { pktSwchPhyInterfaceEntry 12 } pktSwchPhyInterfaceTestLostFrames OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Percentage of the frames which were lost during the TEST." ::= { pktSwchPhyInterfaceEntry 13 } -- The PS X.25 Group contains the Lapb Table, the PLP Table pktSwchx25 OBJECT IDENTIFIER ::= { radPS 4 } pktSwchLapb OBJECT IDENTIFIER ::= { pktSwchx25 1 } -- The PS Lapb Scratch Table pktSwchLapbSTable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchLapbSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Lapb Table includes statistics and configurable objects provided by the PS that are not included in RFC 1381." ::= { pktSwchLapb 1 } pktSwchLapbSEntry OBJECT-TYPE SYNTAX PktSwchLapbSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in the RAD Lapb Table." INDEX { pktSwchLapbLinkNumberS } ::= { pktSwchLapbSTable 1 } PktSwchLapbSEntry ::= SEQUENCE { pktSwchLapbLinkNumberS Integer32, pktSwchLapbInternalClockS INTEGER, pktSwchLapbLineOptionS Integer32, pktSwchLapbSegmentSizeS Integer32, pktSwchLapbXIDS Integer32, pktSwchLapbAckCounterS Integer32, pktSwchLapbAckTimerS Integer32 } pktSwchLapbLinkNumberS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The link number with which this entry is associated. This value corresponds to pktSwchPhyInterfaceNumber. There is an entry for each link for which the pktSwchPhyInterfaceProtocol is X.25 and one entry for each link and DLCI if the pktSwchPhyInterfaceProtocol for the link is Frame Relay and the DLCI is defined as using X.25." ::= { pktSwchLapbSEntry 1 } pktSwchLapbInternalClockS OBJECT-TYPE SYNTAX INTEGER { r2400bps (1), r4800bps (2), r9600bps (3), r14400bps(4), r19200bps(5), r38400bps(6), r48Kbps (7), r56Kbps (8), r64Kbps (9), r128Kbps (10), r256Kbps (11), r384Kbps (12), r504Kbps (13), r768Kbps (14), r1008Kbps(15), r1466Kbps(16), r2016Kbps(17), external(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "The internal clock speed to be used on this LAPB link. If external clock is used, the value is 255." ::= { pktSwchLapbSEntry 2 } pktSwchLapbLineOptionS OBJECT-TYPE SYNTAX Integer32 (0..2048) MAX-ACCESS read-write STATUS current DESCRIPTION "The line option to be used on this link. A value of zero indicates no options. A value between 0 and 255 inclusive specifes a time in minutes after which the line will be disconnected if no session is open. The following values have the associated meanings: 256 Dialed line 512 Return to leased line 1024 DTR is ON permanent 2048 DTR is OFF permanent. any valid combination of the above options should be represented as a sum of the corresponding values. Valid combinations are: DTR ON or OFF (but not both). Dialed line options or not applicable. If DTR control is on (256), then all combinations are possible except 1024 and 2048 (which are not possible)." ::= { pktSwchLapbSEntry 3 } pktSwchLapbSegmentSizeS OBJECT-TYPE SYNTAX Integer32 (1..4096) MAX-ACCESS read-write STATUS current DESCRIPTION "This value is for the use of billing information. The value can be no larger than the maximum packet size." ::= { pktSwchLapbSEntry 4 } pktSwchLapbXIDS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "When this parameter is different than zero, this lapb is configured as a V25 bis dialed link. This is the XID entry Index which this dialed link is associated with." ::= { pktSwchLapbSEntry 5 } pktSwchLapbAckCounterS OBJECT-TYPE SYNTAX Integer32 (1..128) MAX-ACCESS read-write STATUS current DESCRIPTION "This object defines how many frames will be received on the link before the PS will send Acknowledge (RR frame). It is used for Piggy Back Acknowledge (ack within the info frames) and saves traffic on the line. Default value: 1 ." ::= { pktSwchLapbSEntry 6 } pktSwchLapbAckTimerS OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "The Ack Timer defines the maximum time in seconds that the device will wait before sending RR acknowledgment on the received frames. It is used for Piggy Back Acknowledge (ack within the info frames) and saves traffic on the line. Default value: 0 ." ::= { pktSwchLapbSEntry 7 } -- The PS Lapb Active Table pktSwchLapbATable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchLapbAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Lapb Table includes statistics and configurable objects provided by the PS that are not included in RFC 1381." ::= { pktSwchLapb 2 } pktSwchLapbAEntry OBJECT-TYPE SYNTAX PktSwchLapbAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in the RAD Lapb Table." INDEX { pktSwchLapbLinkNumberA } ::= { pktSwchLapbATable 1 } PktSwchLapbAEntry ::= SEQUENCE { pktSwchLapbLinkNumberA Integer32, pktSwchLapbInternalClockA INTEGER, pktSwchLapbLineOptionA Integer32, pktSwchLapbSegmentSizeA Integer32, pktSwchLapbLineProtocol INTEGER, pktSwchLapbLowerId Integer32, pktSwchLapbXIDA Integer32, pktSwchLapbTransmittedIFrames Counter32, pktSwchLapbReceivedIFrames Counter32, pktSwchLapbNSError Counter32, pktSwchLapbTransmittedRRFrames Counter32, pktSwchLapbReceivedRRFrames Counter32, pktSwchLapbTransmittedRNRFrames Counter32, pktSwchLapbReceivedRNRFrames Counter32, pktSwchLapbTransmittedFRMRFrames Counter32, pktSwchLapbReceivedFRMRFrames Counter32, pktSwchLapbAckCounterA Integer32, pktSwchLapbAckTimerA Integer32 } pktSwchLapbLinkNumberA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The link number with which this entry is associated. This value corresponds to pktSwchPhyInterfaceNumber. There is an entry for each link for which the pktSwchPhyInterfaceProtocol is X.25 and one entry for each link and DLCI if the pktSwchPhyInterfaceProtocol for the link is Frame Relay and theDLCI is defined as using X.25." ::= { pktSwchLapbAEntry 1 } pktSwchLapbInternalClockA OBJECT-TYPE SYNTAX INTEGER { r2400bps (1), r4800bps (2), r9600bps (3), r14400bps(4), r19200bps(5), r38400bps(6), r48Kbps (7), r56Kbps (8), r64Kbps (9), r128Kbps (10), r256Kbps (11), r384Kbps (12), r504Kbps (13), r768Kbps (14), r1008Kbps(15), r1466Kbps(16), r2016Kbps(17), external(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "The internal clock speed currently used on this LAPB link. If external clock is used, the value is 255." ::= { pktSwchLapbAEntry 2 } pktSwchLapbLineOptionA OBJECT-TYPE SYNTAX Integer32 (0..2048) MAX-ACCESS read-only STATUS current DESCRIPTION "The line option currently used on this link. A value of zero indicates no options. A value between 1 and 255 inclusive specifes a time in minutes after which the line will be disconnected if no session is open. The following values have the associated meanings: 256 Dialed line 512 Return to leased line 1024 DTR is ON permanent 2048 DTR is OFF permanent. any valid combination of the above options should be represented as a sum of the corresponding values. Valid combinations are: DTR ON or OFF (but not both). Dialed line options or not applicable. If DTR control is on (256), then all combinations are possible except 1024 and 2048 (which are not possible)." ::= { pktSwchLapbAEntry 3 } pktSwchLapbSegmentSizeA OBJECT-TYPE SYNTAX Integer32 (1..4096) MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the segment size." ::= { pktSwchLapbAEntry 4 } pktSwchLapbLineProtocol OBJECT-TYPE SYNTAX INTEGER { unknown(1), x25 (2), fr (3), isdn (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is the lower level protocol which runs under this lapb interface." ::= { pktSwchLapbAEntry 5 } pktSwchLapbLowerId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "In case of X.25 over Frame-relay this is the lower level link number." ::= { pktSwchLapbAEntry 6 } pktSwchLapbXIDA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "When this parameter is different than zero, this lapb is configured as a V25 bis dialed link. This is the XID entry which this dialed link is associated with." ::= { pktSwchLapbAEntry 7 } pktSwchLapbTransmittedIFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitted I frames on this link." ::= { pktSwchLapbAEntry 8 } pktSwchLapbReceivedIFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The received I frames on this link." ::= { pktSwchLapbAEntry 9 } pktSwchLapbNSError OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of I frames transmitted out of sequence." ::= { pktSwchLapbAEntry 10 } pktSwchLapbTransmittedRRFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitted RR frames on this link." ::= { pktSwchLapbAEntry 11 } pktSwchLapbReceivedRRFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The received RR frames on this link." ::= { pktSwchLapbAEntry 12 } pktSwchLapbTransmittedRNRFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitted RNR frames on this link." ::= { pktSwchLapbAEntry 13 } pktSwchLapbReceivedRNRFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The received RNR frames on this link." ::= { pktSwchLapbAEntry 14 } pktSwchLapbTransmittedFRMRFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitted FRMR frames on this link." ::= { pktSwchLapbAEntry 15 } pktSwchLapbReceivedFRMRFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The received FRMR frames on this link." ::= { pktSwchLapbAEntry 16 } pktSwchLapbAckCounterA OBJECT-TYPE SYNTAX Integer32 (1..128) MAX-ACCESS read-only STATUS current DESCRIPTION "This object defines how many frames will be received on the link before the PS will send Acknowledge (RR frame). It is used for Piggy Back Acknowledge (ack within the info frames) and saves traffic on the line. Default value: 1 ." ::= { pktSwchLapbAEntry 17 } pktSwchLapbAckTimerA OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The Ack Timer defines the maximum time in seconds that the device will wait before sending RR acknowledgment on the received frames. It is used for Piggy Back Acknowledge (ack within the info frames) and saves traffic on the line. Default value: 0 ." ::= { pktSwchLapbAEntry 18 } -- PLP (Packet Layer Protocol: Scratch + Active} pktSwchPlp OBJECT IDENTIFIER ::= { pktSwchx25 2 } -- PLP Scratch table pktSwchPlpSTable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchPlpSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Scratch Plp Table includes configurable objects provided by the PS that are not included in RFC 1382." ::= { pktSwchPlp 1 } pktSwchPlpSEntry OBJECT-TYPE SYNTAX PktSwchPlpSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in the RAD Scratch Plp Table." INDEX { pktSwchPlpLinkNumberS } ::= { pktSwchPlpSTable 1 } PktSwchPlpSEntry ::= SEQUENCE { pktSwchPlpLinkNumberS Integer32, pktSwchPlpInCallOptionS Integer32, pktSwchPlpOutCallOptionS Integer32, pktSwchPlpCugSubscriptionS INTEGER, pktSwchPlpNUIS Integer32, pktSwchPlpCpyPktSize Integer32, pktSwchPlpCpyWinSize Integer32 } pktSwchPlpLinkNumberS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The ifIndex of the X.25 interface." ::= { pktSwchPlpSEntry 1 } pktSwchPlpInCallOptionS OBJECT-TYPE SYNTAX Integer32 (0..15) MAX-ACCESS read-write STATUS current DESCRIPTION "The in call options for the link. The value is a sum of values (powers of two), where each value in the sum represents an option. The values that may be included in the sum and their meanings are: 0 No options 1 Fast select acceptance - included in RFC 1382 2 Reverse charge acceptance - included in RFC 1382 4 Subaddress in Call User Data field (CUD) 8 Protocol ID (PID) is not used." ::= { pktSwchPlpSEntry 2 } pktSwchPlpOutCallOptionS OBJECT-TYPE SYNTAX Integer32 (0..15) MAX-ACCESS read-write STATUS current DESCRIPTION "The out call options for the link. The value is a sum of values (powers of two), where each value in the sum represents an option. The values that may be included in the sum and their meanings are: 0 No options 1 Don't add calling and call addressin call accept packet 2 Network link, call request spread enabled 4 Add source link number to called address 8 Don't change calling address XX - Any combination of the values specified above." ::= { pktSwchPlpSEntry 3 } pktSwchPlpCugSubscriptionS OBJECT-TYPE SYNTAX INTEGER { cug(1), -- CUG with preferential cugOa(2), -- CUG/OA with preferential cugIa(3), -- CUG/IA with preferential cugOaIa(4), -- CUG/OA/IA with preferential noPref(5), -- CUG/OA/IA without preferential (transparent) noCug(255) -- no CUG } MAX-ACCESS read-write STATUS current DESCRIPTION "The CUG subscription for the link." ::= { pktSwchPlpSEntry 4 } pktSwchPlpNUIS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This is the NUI group which this Plp is part of." ::= { pktSwchPlpSEntry 5 } pktSwchPlpCpyPktSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "x25 packet size." ::= { pktSwchPlpSEntry 6 } pktSwchPlpCpyWinSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "x25 window size." ::= { pktSwchPlpSEntry 7 } -- PLP Active table pktSwchPlpATable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchPlpAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Active Plp Table includes objects provided by the PS that are not included in RFC 1382. It also includes some packet layer statistics, some of which are defined in RFC 1382, but are not supported there, as the x25StatTable in RFC 1382 is not supported." ::= { pktSwchPlp 2 } pktSwchPlpAEntry OBJECT-TYPE SYNTAX PktSwchPlpAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in the RAD Active Plp Table." INDEX { pktSwchPlpLinkNumberA } ::= { pktSwchPlpATable 1 } PktSwchPlpAEntry ::= SEQUENCE { pktSwchPlpLinkNumberA Integer32, pktSwchPlpInCallOptionA Integer32, pktSwchPlpOutCallOptionA Integer32, pktSwchPlpCugSubscriptionA INTEGER, pktSwchPlpNUIA Integer32, pktSwchStatOutRestarts Counter32 } pktSwchPlpLinkNumberA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The link number with which this entry is associated. This value corresponds to pktSwchPhyInterfaceNumber. There is an entry for each link for which the pktSwchPhyInterfaceProtocol is X.25 and one entry for each link and DLCI if the pktSwchPhyInterfaceProtocol for the link is Frame Relay and theDLCI is defined as using X.25." ::= { pktSwchPlpAEntry 1 } pktSwchPlpInCallOptionA OBJECT-TYPE SYNTAX Integer32 (0..15) MAX-ACCESS read-only STATUS current DESCRIPTION "The current in call options for the link. The value is a sum of values (powers of two), where each value in the sum represents an option. The values that can be included in the sum and their meanings are: 0 No options 1 Fast select acceptance - included in RFC 1382 2 Reverse charge acceptance - included in RFC 1382 4 Subaddress in Call User Data field (CUD) 8 Protocol ID (PID) is not used." ::= { pktSwchPlpAEntry 2 } pktSwchPlpOutCallOptionA OBJECT-TYPE SYNTAX Integer32 (0..15) MAX-ACCESS read-only STATUS current DESCRIPTION "The out call options for the link. The value is a sum of values (powers of two), where each value in the sum represents an option. The values that may be included in the sum and their meanings are: 0 No options 1 Don't add calling and call addressin call accept packet 2 Network link, call request spread enabled 4 Add source link number to called address 8 Don't change calling address XX - Any combination of the values specified above." ::= { pktSwchPlpAEntry 3 } pktSwchPlpCugSubscriptionA OBJECT-TYPE SYNTAX INTEGER { cug(1), -- CUG with preferential cugOa(2), -- CUG/OA with preferential cugIa(3), -- CUG/IA with preferential cugOaIa(4), -- CUG/OA/IA with preferential noPref(5), -- CUG/OA/IA without preferential (transparent) noCug(255) -- no CUG } MAX-ACCESS read-only STATUS current DESCRIPTION "The current CUG subscription for the link." ::= { pktSwchPlpAEntry 4 } pktSwchPlpNUIA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is the NUI group which this Plp is part of." ::= { pktSwchPlpAEntry 5 } pktSwchStatOutRestarts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of remotely initiated (including provider initiated) restarts experienced by the PLE excluding the restart associated with bringing up the PLE interface. This only counts restarts received when the PLE already has an established connection with the remove PLE." ::= { pktSwchPlpAEntry 6 } pktSwchPlaceHolderForFutureUse OBJECT IDENTIFIER ::= { pktSwchx25 3 } -- CUG (Scratch + Active} pktSwchCug OBJECT IDENTIFIER ::= { pktSwchx25 4 } -- CUG Scratch table pktSwchCugSTable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchCugSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Scratch Cug Table lists the Closed User Groups defined to each X.25 link." ::= { pktSwchCug 1 } pktSwchCugSEntry OBJECT-TYPE SYNTAX PktSwchCugSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in the Scratch RAD Cug Table." INDEX { pktSwchCugLinkNumberS, pktSwchCugIndexS } ::= { pktSwchCugSTable 1 } PktSwchCugSEntry ::= SEQUENCE { pktSwchCugLinkNumberS Integer32, pktSwchCugIndexS Integer32, pktSwchCugNumberS Integer32, pktSwchCugStatus INTEGER } pktSwchCugLinkNumberS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The link number with which this entry is associated. This value corresponds to pktSwchPhyInterfaceNumber. There is an entry for each link for which the pktSwchPhyInterfaceProtocol is X.25 if the link has CUG options and one entry for each link and DLCI if the pktSwchPhyInterfaceProtocol for the link is Frame Relay and the DLCI is defined as using X.25 if the link has CUG options." ::= { pktSwchCugSEntry 1 } pktSwchCugIndexS OBJECT-TYPE SYNTAX Integer32 -- how many CUGs?? MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CUG for a specific link. The lowest indexed CUG is the preferential CUG." ::= { pktSwchCugSEntry 2 } pktSwchCugNumberS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The CUG number for this entry." ::= { pktSwchCugSEntry 3 } pktSwchCugStatus OBJECT-TYPE SYNTAX INTEGER { valid(1), createRequest(2), underCreation(3), invalid(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The status of this CUG table entry. The choices are those defined in the SNMPv2 Textual Conventions for RowStatus. This will allow easy replacement of the INTEGER syntax with the RowStatus textual convention SYNTAX." ::= { pktSwchCugSEntry 4 } -- CUG Active table pktSwchCugATable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchCugAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Active Cug Table lists the active Closed User Groups defined to each X.25 link." ::= { pktSwchCug 2 } pktSwchCugAEntry OBJECT-TYPE SYNTAX PktSwchCugAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in the Active RAD Cug Table." INDEX { pktSwchCugLinkNumberA, pktSwchCugIndexA } ::= { pktSwchCugATable 1 } PktSwchCugAEntry ::= SEQUENCE { pktSwchCugLinkNumberA Integer32, pktSwchCugIndexA Integer32, pktSwchCugNumberA Integer32 } pktSwchCugLinkNumberA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The link number with which this entry is associated. This value corresponds to pktSwchPhyInterfaceNumber. There is an entry for each link for which the pktSwchPhyInterfaceProtocol is X.25 if the link has CUG options and one entry for each link and DLCI if the pktSwchPhyInterfaceProtocol for the link is Frame Relay and theDLCI is defined as using X.25 if the link has CUG options." ::= { pktSwchCugAEntry 1 } pktSwchCugIndexA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CUG for a specific link. The lowest indexed CUG is the preferential CUG." ::= { pktSwchCugAEntry 2 } pktSwchCugNumberA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The CUG number for this entry." ::= { pktSwchCugAEntry 3 } -- X.25 Channel LCN Table pktSwchLogCh OBJECT IDENTIFIER ::= { pktSwchx25 5 } pktSwchLogChAssTable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchLogChAssEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "These objects contain information about the channel number configuration in an X.25 PLE. These values are the configured values. changes in these values after the interface has started may not be reflected in the operating PLE." REFERENCE "See ISO 8208, Section 3.7" ::= {pktSwchLogCh 1 } pktSwchLogChAssEntry OBJECT-TYPE SYNTAX PktSwchLogChAssEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries of pktSwchLogChAssTable." REFERENCE "This provides the information available in 10733 logicalChannelAssignments." INDEX { pktSwchLogChAssIndex } ::= { pktSwchLogChAssTable 1 } PktSwchLogChAssEntry ::= SEQUENCE { pktSwchLogChAssIndex IfIndexType, pktSwchLogChAssLIC Integer32, pktSwchLogChAssHIC Integer32, pktSwchLogChAssLTC Integer32, pktSwchLogChAssHTC Integer32, pktSwchLogChAssLOC Integer32, pktSwchLogChAssHOC Integer32 } pktSwchLogChAssIndex OBJECT-TYPE SYNTAX IfIndexType MAX-ACCESS read-only STATUS current DESCRIPTION "The ifIndex value for the X.25 Interface." ::= { pktSwchLogChAssEntry 1 } pktSwchLogChAssLIC OBJECT-TYPE SYNTAX Integer32 (0..4095) MAX-ACCESS read-only STATUS current DESCRIPTION "Lowest Incoming channel." ::= { pktSwchLogChAssEntry 2 } pktSwchLogChAssHIC OBJECT-TYPE SYNTAX Integer32 (0..4095) MAX-ACCESS read-only STATUS current DESCRIPTION "Highest Incoming channel. A value of zero indicates no channels in this range." ::= { pktSwchLogChAssEntry 3 } pktSwchLogChAssLTC OBJECT-TYPE SYNTAX Integer32 (0..4095) MAX-ACCESS read-only STATUS current DESCRIPTION "Lowest Two-way channel." ::= { pktSwchLogChAssEntry 4 } pktSwchLogChAssHTC OBJECT-TYPE SYNTAX Integer32 (0..4095) MAX-ACCESS read-only STATUS current DESCRIPTION "Highest Two-way channel. A value of zero indicates no channels in this range." ::= { pktSwchLogChAssEntry 5 } pktSwchLogChAssLOC OBJECT-TYPE SYNTAX Integer32 (0..4095) MAX-ACCESS read-only STATUS current DESCRIPTION "Lowest outgoing channel." ::= { pktSwchLogChAssEntry 6 } pktSwchLogChAssHOC OBJECT-TYPE SYNTAX Integer32 (0..4095) MAX-ACCESS read-only STATUS current DESCRIPTION "Highest outgoing channel. A value of zero indicates no channels in this range." ::= { pktSwchLogChAssEntry 7 } pktSwchLogChPartnerTable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchLogChPartnerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "These objects contain information about the partner channel number configuration in an X.25 PLE. These values are the configured values. changes in these values after the interfaces has started may not be reflected in the operating PLE." REFERENCE "See ISO 8208, Section 3.7" ::= {pktSwchLogCh 2 } pktSwchLogChPartnerEntry OBJECT-TYPE SYNTAX PktSwchLogChPartnerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries of pktSwchLogChPartnerTable." REFERENCE "This provides the information available in 10733 logicalChannelPartners." INDEX { pktSwchLogChPartnerIfIndex, pktSwchLogChPartnerLcIndex } ::= { pktSwchLogChPartnerTable 1 } PktSwchLogChPartnerEntry ::= SEQUENCE { pktSwchLogChPartnerIfIndex IfIndexType, pktSwchLogChPartnerLcIndex Integer32, pktSwchLogChPartnerProtocol INTEGER, pktSwchLogChPartnerOpIfIndex IfIndexType, pktSwchLogChPartnerOpLcIndex Integer32 } pktSwchLogChPartnerIfIndex OBJECT-TYPE SYNTAX IfIndexType MAX-ACCESS read-only STATUS current DESCRIPTION "The ifIndex value for the Lapb Interface." ::= { pktSwchLogChPartnerEntry 1 } pktSwchLogChPartnerLcIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The Index value for the LCN." ::= { pktSwchLogChPartnerEntry 2 } pktSwchLogChPartnerProtocol OBJECT-TYPE SYNTAX INTEGER { other(1), x25(2), hdlc(3), sdlc(4), async(5), mpe(6), ip(7) } MAX-ACCESS read-only STATUS current DESCRIPTION " The protocol of the partner." ::= { pktSwchLogChPartnerEntry 3 } pktSwchLogChPartnerOpIfIndex OBJECT-TYPE SYNTAX IfIndexType MAX-ACCESS read-only STATUS current DESCRIPTION "The ifIndex value for the partner Lapb Interface." ::= { pktSwchLogChPartnerEntry 4 } pktSwchLogChPartnerOpLcIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The Index value for the partner LCN." ::= { pktSwchLogChPartnerEntry 5 } -- The PS HDLC Group contains HDLC Scratch and Active Tables, which contain configuration for -- HDLC links pktSwchHdlc OBJECT IDENTIFIER ::= { radPS 5 } pktSwchHdlcSTable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchHdlcSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Scratch Hdlc Table contains configuration information for HDLC links" ::= { pktSwchHdlc 1 } pktSwchHdlcSEntry OBJECT-TYPE SYNTAX PktSwchHdlcSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in the RAD Hdlc Table." INDEX { pktSwchHdlcLinkNumberS } ::= { pktSwchHdlcSTable 1 } PktSwchHdlcSEntry ::= SEQUENCE { pktSwchHdlcLinkNumberS Integer32, pktSwchHdlcDestAddrS DisplayString, pktSwchHdlcDestSubAddrS Integer32, pktSwchHdlcRedialTimeoutS Integer32, pktSwchHdlcRedialRetriesS Integer32, pktSwchHdlcInactivityS Integer32, pktSwchHdlcX25FacilitiesS Integer32, pktSwchHdlcLocalSubaddr1S Integer32, pktSwchHdlcLocalSubaddr2S Integer32, pktSwchHdlcDestDlciS Integer32, pktSwchHdlcDestPortS Integer32, pktSwchHdlcProtocolS INTEGER, pktSwchHdlcFlowContOptionsS Integer32, pktSwchHdlcBufferFlowControlS Integer32, pktSwchHdlcInternalClockS INTEGER, pktSwchHdlcNrzModeS Integer32 } pktSwchHdlcLinkNumberS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The link number with which this entry is associated. This value corresponds to pktSwchPhyInterfaceNumber. There is an entry for each link for which the pktSwchPhyInterfaceProtocol is HDLC." ::= { pktSwchHdlcSEntry 1 } pktSwchHdlcDestAddrS OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The destination address. It defines the X.25 address on the remote device." ::= { pktSwchHdlcSEntry 2 } pktSwchHdlcDestSubAddrS OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-write STATUS current DESCRIPTION "The destination subaddress. It defines the synchronous link subaddress on the remote device." ::= { pktSwchHdlcSEntry 3 } pktSwchHdlcRedialTimeoutS OBJECT-TYPE SYNTAX Integer32 (0..255) -- seconds?? MAX-ACCESS read-write STATUS current DESCRIPTION "The time interval in seconds between two consecutive connect operations retries." ::= { pktSwchHdlcSEntry 4 } pktSwchHdlcRedialRetriesS OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "This defines how many times the call operation is repeated if the call request has failed." ::= { pktSwchHdlcSEntry 5 } pktSwchHdlcInactivityS OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "The amount of time in minutes of inactivity that will cause the session to disconnect." ::= { pktSwchHdlcSEntry 6 } pktSwchHdlcX25FacilitiesS OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "This specifies the X.25 facilities. The value is a sum of values (powers of two), where each value in the sum represents an option. The values that may be included in the sum and their meanings are: 0 No options 1 Packet size negotiation 2 Window size negotiation 4 Reverse charge." ::= { pktSwchHdlcSEntry 7 } pktSwchHdlcLocalSubaddr1S OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-write STATUS current DESCRIPTION "The first local subaddress." ::= { pktSwchHdlcSEntry 8 } pktSwchHdlcLocalSubaddr2S OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-write STATUS current DESCRIPTION "The secondary local subaddress." ::= { pktSwchHdlcSEntry 9 } pktSwchHdlcDestDlciS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The local DLCI which is used for HDLC encapsulation over Frame Relay. Range: 16...991" ::= { pktSwchHdlcSEntry 10 } pktSwchHdlcDestPortS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The local port that is used for HDLC encapsulation over Frame Relay. Range: 1...12" ::= { pktSwchHdlcSEntry 11 } pktSwchHdlcProtocolS OBJECT-TYPE SYNTAX INTEGER { hdlcOverX25(1), -- HDLC encapsulated over X.25 hdlcOverFrRel(2), -- HDLC encapsulated over Frame Relay hdlcOverMpe(3), -- HDLC encapsulated over MPE hdlcReg(4), -- HDLC regular protocol for inner routing hdlcOverIp(5) -- HDLC encapsulated over IP } MAX-ACCESS read-write STATUS current DESCRIPTION "The HDLC protocol type." ::= { pktSwchHdlcSEntry 12 } pktSwchHdlcFlowContOptionsS OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-write STATUS current DESCRIPTION "This specifies the type of flow control of the HDLC link. The value is a sum of values (powers of two), where each value in the sum represents an option. The values that may be included in the sum and their meanings are: 0 No flow control 1 CTS flow control 2 Clock flow control." ::= { pktSwchHdlcSEntry 13 } pktSwchHdlcBufferFlowControlS OBJECT-TYPE SYNTAX Integer32 (1..200) MAX-ACCESS read-write STATUS current DESCRIPTION "The number of buffers that will be allocated for the HDLC link. Default value is 10" ::= { pktSwchHdlcSEntry 14 } pktSwchHdlcInternalClockS OBJECT-TYPE SYNTAX INTEGER { r2400bps (1), r4800bps (2), r9600bps (3), r14400bps(4), r19200bps(5), r38400bps(6), r48Kbps (7), r56Kbps (8), r64Kbps (9), r128Kbps (10), r256Kbps (11), r384Kbps (12), r504Kbps (13), r768Kbps (14), r1008Kbps(15), r1466Kbps(16), r2016Kbps(17), external(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "The baud rate of the internal clock." ::= { pktSwchHdlcSEntry 15 } pktSwchHdlcNrzModeS OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "The data encoding format. The value is a sum of values (powers of two), where each value in the sum represents an option. The values that may be included in the sum and their meanings are: 0 NRZ 1 NRZI 2 Transmit Idles between frames and control the RTS pin 4 Normal Operation (DCD, CTS lines under automatic control) XX Any combination of the values specified above." ::= { pktSwchHdlcSEntry 16 } pktSwchHdlcATable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchHdlcAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Active Hdlc Table contains active configuration information for HDLC links" ::= { pktSwchHdlc 2 } pktSwchHdlcAEntry OBJECT-TYPE SYNTAX PktSwchHdlcAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in the RAD Hdlc Table." INDEX { pktSwchHdlcLinkNumberA } ::= { pktSwchHdlcATable 1 } PktSwchHdlcAEntry ::= SEQUENCE { pktSwchHdlcLinkNumberA Integer32, pktSwchHdlcDestAddrA DisplayString, pktSwchHdlcDestSubAddrA Integer32, pktSwchHdlcRedialTimeoutA Integer32, pktSwchHdlcRedialRetriesA Integer32, pktSwchHdlcInactivityA Integer32, pktSwchHdlcX25FacilitiesA Integer32, pktSwchHdlcLocalSubaddr1A Integer32, pktSwchHdlcLocalSubaddr2A Integer32, pktSwchHdlcDestDlciA Integer32, pktSwchHdlcDestPortA Integer32, pktSwchHdlcProtocolA INTEGER, pktSwchHdlcFlowContOptionsA Integer32, pktSwchHdlcBufferFlowControlA Integer32, pktSwchHdlcInternalClockA INTEGER, pktSwchHdlcNrzModeA Integer32, pktSwchHdlcConnStatus INTEGER, pktSwchHdlcSpecialStatus INTEGER, pktSwchHdlcCtsStatus INTEGER, pktSwchHdlcRunningX25Lcn DisplayString, pktSwchHdlcRunningDlci DisplayString, pktSwchHdlcMaxBuffToNet Integer32, pktSwchHdlcBuffToNet Integer32 } pktSwchHdlcLinkNumberA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The link number with which this entry is associated. This value corresponds to pktSwchPhyInterfaceNumber. There is an entry for each link for which the pktSwchPhyInterfaceProtocol is HDLC." ::= { pktSwchHdlcAEntry 1 } pktSwchHdlcDestAddrA OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The destination address. It defines the X.25 address on the remote device." ::= { pktSwchHdlcAEntry 2 } pktSwchHdlcDestSubAddrA OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "The destination subaddress. It defines the synchronous link subaddress on the remote device." ::= { pktSwchHdlcAEntry 3 } pktSwchHdlcRedialTimeoutA OBJECT-TYPE SYNTAX Integer32 (0..255) -- seconds?? MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval in seconds between two consecutive connect operations retries." ::= { pktSwchHdlcAEntry 4 } pktSwchHdlcRedialRetriesA OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This defines how many times the call operation is repeated if the call request has failed." ::= { pktSwchHdlcAEntry 5 } pktSwchHdlcInactivityA OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of time in minutes of inactivity that will cause the session to disconnect." ::= { pktSwchHdlcAEntry 6 } pktSwchHdlcX25FacilitiesA OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "This specifies the X.25 facilities. The value is a sum of values (powers of two), where each value in the sum represents an option. The values that may be included in the sum and their meanings are: 0 No options 1 Packet size negotiation 2 Window size negotiation 4 Reverse charge." ::= { pktSwchHdlcAEntry 7 } pktSwchHdlcLocalSubaddr1A OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "The first local subaddress." ::= { pktSwchHdlcAEntry 8 } pktSwchHdlcLocalSubaddr2A OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "The secondary local subaddress." ::= { pktSwchHdlcAEntry 9 } pktSwchHdlcDestDlciA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The local DLCI which is used for HDLC encapsulation over Frame Relay." ::= { pktSwchHdlcAEntry 10 } pktSwchHdlcDestPortA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The local port that is used for HDCL encapsulation over Frame Relay." ::= { pktSwchHdlcAEntry 11 } pktSwchHdlcProtocolA OBJECT-TYPE SYNTAX INTEGER { hdlcOverX25(1), -- HDLC encapsulated over X.25 hdlcOverFrRel(2), -- HDLC encapsulated over Frame Relay hdlcOverMpe(3), -- HDLC encapsulated over MPE hdlcReg(4), -- HDLC regular protocol for inner routing hdlcOverIp(5) -- It is actually IP over HDLC } MAX-ACCESS read-only STATUS current DESCRIPTION "The HDLC protocol type." ::= { pktSwchHdlcAEntry 12 } pktSwchHdlcFlowContOptionsA OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "This specifies the type of flow control of the HDLC link. The value is a sum of values (powers of two), where each value in the sum represents an option. The values that may be included in the sum and their meanings are: 0 No flow control 1 CTS flow control 2 Clock flow control." ::= { pktSwchHdlcAEntry 13 } pktSwchHdlcBufferFlowControlA OBJECT-TYPE SYNTAX Integer32 (1..200) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of buffers that will be allocated for the HDLC link." ::= { pktSwchHdlcAEntry 14 } pktSwchHdlcInternalClockA OBJECT-TYPE SYNTAX INTEGER { r2400bps (1), r4800bps (2), r9600bps (3), r14400bps(4), r19200bps(5), r38400bps(6), r48Kbps (7), r56Kbps (8), r64Kbps (9), r128Kbps (10), r256Kbps (11), r384Kbps (12), r504Kbps (13), r768Kbps (14), r1008Kbps(15), r1466Kbps(16), r2016Kbps(17), external(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "The baud rate of the internal clock." ::= { pktSwchHdlcAEntry 15 } pktSwchHdlcNrzModeA OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "The data encoding format. The value is a sum of values (powers of two), where each value in the sum represents an option. The values that may be included in the sum and their meanings are: 0 NRZ 1 NRZI 2 Transmit Idles between frames and control the RTS pin 4 Normal Operation (DCD, CTS lines under automatic control) XX Any combination of the values specified above." ::= { pktSwchHdlcAEntry 16 } pktSwchHdlcConnStatus OBJECT-TYPE SYNTAX INTEGER { disconnect(1), connect(2), pvc(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the Hdlc session." ::= { pktSwchHdlcAEntry 17 } pktSwchHdlcSpecialStatus OBJECT-TYPE SYNTAX INTEGER { busy(1), overflow(2), noStatus(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the Hdlc link." ::= { pktSwchHdlcAEntry 18 } pktSwchHdlcCtsStatus OBJECT-TYPE SYNTAX INTEGER { off(2), on(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The CTS status." ::= { pktSwchHdlcAEntry 19 } pktSwchHdlcRunningX25Lcn OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The format of the string is ifIndex:LCN " ::= { pktSwchHdlcAEntry 20 } pktSwchHdlcRunningDlci OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The format of the string is ifIndex:DLCI" ::= { pktSwchHdlcAEntry 21 } pktSwchHdlcMaxBuffToNet OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of buffers above which Flow Control is enabled" ::= { pktSwchHdlcAEntry 22 } pktSwchHdlcBuffToNet OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of buffers waiting for transmission." ::= { pktSwchHdlcAEntry 23 } pktSwchStmTable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchStmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The STM table contains information for STM links" ::= { radPS 7 } pktSwchStmEntry OBJECT-TYPE SYNTAX PktSwchStmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in the RAD STM Table." INDEX { pktSwchStmLinkNumber } ::= { pktSwchStmTable 1 } PktSwchStmEntry ::= SEQUENCE { pktSwchStmLinkNumber Integer32, pktSwchStmInternalClockS INTEGER, pktSwchStmInternalClockA INTEGER, pktSwchStmConn INTEGER, pktSwchStmSyncLoss Counter32 } pktSwchStmLinkNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The link number with which this entry is associated. This value corresponds to pktSwchPhyInterfaceNumber. There is an entry for each link whose pktSwchPhyInterfaceProtocol is STM 4, 8, 16, or 24." ::= { pktSwchStmEntry 1 } pktSwchStmInternalClockS OBJECT-TYPE SYNTAX INTEGER { r2400bps (1), r4800bps (2), r9600bps (3), r14400bps(4), r19200bps(5), r38400bps(6), r48Kbps (7), r56Kbps (8), r64Kbps (9), r128Kbps (10), r256Kbps (11), r384Kbps (12), r504Kbps (13), r768Kbps (14), r1008Kbps(15), r1466Kbps(16), r2016Kbps(17), external(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "The baud rate of the internal clock." ::= { pktSwchStmEntry 2 } pktSwchStmInternalClockA OBJECT-TYPE SYNTAX INTEGER { r2400bps (1), r4800bps (2), r9600bps (3), r14400bps(4), r19200bps(5), r38400bps(6), r48Kbps (7), r56Kbps (8), r64Kbps (9), r128Kbps (10), r256Kbps (11), r384Kbps (12), r504Kbps (13), r768Kbps (14), r1008Kbps(15), r1466Kbps(16), r2016Kbps(17), external(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current baud rate of the internal clock." ::= { pktSwchStmEntry 3 } pktSwchStmConn OBJECT-TYPE SYNTAX INTEGER { disconnect(1), connect(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The connectivity status of the STM interface." ::= { pktSwchStmEntry 4 } pktSwchStmSyncLoss OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter for sync loss." ::= { pktSwchStmEntry 5 } -- The PS Frame Relay Group pktSwchFr OBJECT IDENTIFIER ::= { radPS 8 } pktSwchFrTotFunnels OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of Funnels on the PS." ::= { pktSwchFr 1 } pktSwchFrSTable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchFrSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Frame Relay Scratch Table includes the scratch values of configurable objects provided by the PS that are not included in RFC 1315." ::= { pktSwchFr 2 } pktSwchFrSEntry OBJECT-TYPE SYNTAX PktSwchFrSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in the RAD PS Frame Relay Scratch Table." INDEX { pktSwchFrIfIndexS } ::= { pktSwchFrSTable 1 } PktSwchFrSEntry ::= SEQUENCE { pktSwchFrIfIndexS Integer32, pktSwchFrMaintProtS Integer32, pktSwchFrMaintModeS INTEGER, pktSwchFrRxPoolRedLineS Integer32, pktSwchFrRxPoolOkS Integer32, pktSwchFrTxPoolRedLineS Integer32, pktSwchFrTxPoolOkS Integer32, pktSwchFrTxCeilingS Integer32, pktSwchFrInternalClockS INTEGER, pktSwchFrNrzModeS INTEGER, pktSwchFrDlciHeaderModeS INTEGER, pktSwchFrDcdLinkFailureS INTEGER, pktSwchFrTxIdlesS INTEGER, pktSwchFrOperationModeS INTEGER, pktSwchFrPhysInterfOptionsS INTEGER } pktSwchFrIfIndexS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is the ifIndex of the frame relay port." ::= { pktSwchFrSEntry 1 } pktSwchFrMaintProtS OBJECT-TYPE SYNTAX Integer32 (0..12) MAX-ACCESS read-write STATUS current DESCRIPTION "This defines what maintenance protocol is running over this port. 0 - No maintenance protocol. 1 - ANSI PVC maintenance protocol running on DLCI number 0. 2 - LMI maintenance protocol running on DLCI number 1023. 4 - ITU Q.933 ANNEX A maintenance protocol running on DLCI number 0. 8 - Consolidate Link Layer Management CLLM running on DLCI number 1023. 8 cannot be a choice by itself, it can only be as part of the combination 9, 10, 12. XXX - The combination of 9, 10, 12." ::= { pktSwchFrSEntry 2 } pktSwchFrMaintModeS OBJECT-TYPE SYNTAX INTEGER { user(1), network(2), both(3)} MAX-ACCESS read-write STATUS current DESCRIPTION "This defines the mode of maintenance protocol running over this port." ::= { pktSwchFrSEntry 3 } pktSwchFrRxPoolRedLineS OBJECT-TYPE SYNTAX Integer32 (0..39) MAX-ACCESS read-write STATUS current DESCRIPTION "When the number of empty receive buffers at the port reaches this figure (of frames),the port receiver is congested. This field value should be less than the Rx pool OK field." ::= { pktSwchFrSEntry 4 } pktSwchFrRxPoolOkS OBJECT-TYPE SYNTAX Integer32 (1..40) MAX-ACCESS read-write STATUS current DESCRIPTION "Clear the receive congestion condition when the number of empty receive buffers at the port reaches this figure. This value (of frames) should be greater than the Rx pool red line." ::= { pktSwchFrSEntry 5 } pktSwchFrTxPoolRedLineS OBJECT-TYPE SYNTAX Integer32 (1..500) MAX-ACCESS read-write STATUS current DESCRIPTION "When the number of frames awaiting transmission reaches this figure, the port transmitter is congested. This field value should be greater than the Tx pool OK field." ::= { pktSwchFrSEntry 6 } pktSwchFrTxPoolOkS OBJECT-TYPE SYNTAX Integer32 (0..499) MAX-ACCESS read-write STATUS current DESCRIPTION "Clear the transmit congestion condition when the number of frames awaiting transmission at the port reaches this figure. This value (of frames) should be less than the Tx pool red line." ::= { pktSwchFrSEntry 7 } pktSwchFrTxCeilingS OBJECT-TYPE SYNTAX Integer32 (1..500) MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum allowable transmit pool for this port." ::= { pktSwchFrSEntry 8 } pktSwchFrInternalClockS OBJECT-TYPE SYNTAX INTEGER { r2400bps (1), r4800bps (2), r9600bps (3), r14400bps(4), r19200bps(5), r38400bps(6), r48Kbps (7), r56Kbps (8), r64Kbps (9), r128Kbps (10), r256Kbps (11), r384Kbps (12), r504Kbps (13), r768Kbps (14), r1008Kbps(15), r1466Kbps(16), r2016Kbps(17), external (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "The baud rate of the internal clock." ::= { pktSwchFrSEntry 9 } pktSwchFrNrzModeS OBJECT-TYPE SYNTAX INTEGER { nrz(1), nrzi(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The data encoding format." ::= { pktSwchFrSEntry 10 } pktSwchFrDlciHeaderModeS OBJECT-TYPE SYNTAX INTEGER { two-octets(1), three-octets(2), four-octets(3), four-octets-nomanag(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Dlci Header length for this FR port. Option 4 means that there will be no management Dlci in the range of 1024 to 8388607. The management Dlci will be in the range of 0-15 or 991-1023. Default value: 1." ::= { pktSwchFrSEntry 11 } pktSwchFrDcdLinkFailureS OBJECT-TYPE SYNTAX INTEGER { no-Detect(2), linkFailure-Detect(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Link Failure Detection by DCD. If Link Failure detection by DCD is on - (3), when the DCD is down, the FR SW will detect it and change the FR link status from UP to DOWN. A trap of LINK DOWN will be sent to the NMS. Default: (2)." ::= { pktSwchFrSEntry 12 } pktSwchFrTxIdlesS OBJECT-TYPE SYNTAX INTEGER { no(2), yes(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter shows whether the PS will Transmit Idles between frames and control the RTS pin. Default: no(2)." ::= { pktSwchFrSEntry 13 } pktSwchFrOperationModeS OBJECT-TYPE SYNTAX INTEGER { swControl(2), hwControl(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "When H/W Control is configured, the SCC H/W will detect the change in the DCD or CTS signals and Start or Stop transmission automatically. When S/W Control is configured the S/W will decide when to start or stop the transmission. Default: swControl(2)." ::= { pktSwchFrSEntry 14 } pktSwchFrPhysInterfOptionsS OBJECT-TYPE SYNTAX INTEGER { noOption(2), dds4800bps(3), dds9600bps(4), dds19200bps(5), dds56000bos(6) } MAX-ACCESS read-write STATUS current DESCRIPTION "This is the physical interface. Note that the DDS physical interface H/W does not exist in the FPS-8. It is relevant for other PS devices only. For FPS-8 only the default (noOption) should be used. Default: (2)." ::= { pktSwchFrSEntry 15 } pktSwchFrATable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchFrAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Frame Relay Active Table includes statistics and the active values of configurable objects provided by the PS that are not included in RFC 1315." ::= { pktSwchFr 3 } pktSwchFrAEntry OBJECT-TYPE SYNTAX PktSwchFrAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in the RAD PS Frame Relay Active Table." INDEX { pktSwchFrIfIndexA } ::= { pktSwchFrATable 1 } PktSwchFrAEntry ::= SEQUENCE { pktSwchFrIfIndexA Integer32, pktSwchFrMaintProtA Integer32, pktSwchFrMaintModeA INTEGER, pktSwchFrRxPoolRedLineA Integer32, pktSwchFrRxPoolOkA Integer32, pktSwchFrTxPoolRedLineA Integer32, pktSwchFrTxPoolOkA Integer32, pktSwchFrTxCeilingA Integer32, pktSwchFrInternalClockA INTEGER, pktSwchFrNrzModeA INTEGER, pktSwchFrDlcmiPollingInterval Integer32, pktSwchFrDlcmiFullEnquiryInterval Integer32, pktSwchFrDlcmiErrorThreshold Integer32, pktSwchFrDlcmiMonitoredEvents Integer32, pktSwchFrDlciHeaderModeA INTEGER, pktSwchFrDcdLinkFailureA INTEGER, pktSwchFrTxIdlesA INTEGER, pktSwchFrOperationModeA INTEGER, pktSwchFrPhysInterfOptionsA INTEGER } pktSwchFrIfIndexA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is the ifIndex of the frame relay port." ::= { pktSwchFrAEntry 1 } pktSwchFrMaintProtA OBJECT-TYPE SYNTAX Integer32 (0..12) MAX-ACCESS read-only STATUS current DESCRIPTION "This defines what maintenance protocol is running over this port. 0 - No maintenance protocol. 1 - ANSI PVC maintenance protocol running on DLCI number 0. 2 - LMI maintenance protocol running on DLCI number 1023. 4 - ITU Q.933 ANNEX A maintenance protocol running on DLCI number 0. 8 - Consolidate Link Layer Management CLLM running on DLCI number 1023. 8 cannot be a choice by itself, it can only be as part of the combination 9, 10, 12. XXX - The combination of 9, 10, 12." ::= { pktSwchFrAEntry 2 } pktSwchFrMaintModeA OBJECT-TYPE SYNTAX INTEGER { user(1), network(2), both(3)} MAX-ACCESS read-only STATUS current DESCRIPTION "This defines the mode of maintenance protocol running over this port." ::= { pktSwchFrAEntry 3 } pktSwchFrRxPoolRedLineA OBJECT-TYPE SYNTAX Integer32 (0..39) MAX-ACCESS read-only STATUS current DESCRIPTION "When the number of empty receive buffers at the port reaches this figure (of frames), the port receiver is congested. This field value should be less than the Rx pool OK field." ::= { pktSwchFrAEntry 4 } pktSwchFrRxPoolOkA OBJECT-TYPE SYNTAX Integer32 (1..40) MAX-ACCESS read-only STATUS current DESCRIPTION "Clear the receive congestion condition when the number of empty receive buffers at the port reaches this figure. This value (of frames) should be greater than the Rx pool red line." ::= { pktSwchFrAEntry 5 } pktSwchFrTxPoolRedLineA OBJECT-TYPE SYNTAX Integer32 (1..500) MAX-ACCESS read-only STATUS current DESCRIPTION "When the number of frames awaiting transmission reaches this figure, the port transmitter is congested. This field value should be greater than the Tx pool OK field." ::= { pktSwchFrAEntry 6 } pktSwchFrTxPoolOkA OBJECT-TYPE SYNTAX Integer32 (0..499) MAX-ACCESS read-only STATUS current DESCRIPTION "Clear the transmit congestion condition when the number of frames awaiting transmission at the port reaches this figure. This value (of frames) should be less than the Tx pool red line." ::= { pktSwchFrAEntry 7 } pktSwchFrTxCeilingA OBJECT-TYPE SYNTAX Integer32 (0..500) MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum allowable transmit pool for this port." ::= { pktSwchFrAEntry 8 } pktSwchFrInternalClockA OBJECT-TYPE SYNTAX INTEGER { r2400bps (1), r4800bps (2), r9600bps (3), r14400bps(4), r19200bps(5), r38400bps(6), r48Kbps (7), r56Kbps (8), r64Kbps (9), r128Kbps (10), r256Kbps (11), r384Kbps (12), r504Kbps (13), r768Kbps (14), r1008Kbps(15), r1466Kbps(16), r2016Kbps(17), external (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "The baud rate of the internal clock." ::= { pktSwchFrAEntry 9 } pktSwchFrNrzModeA OBJECT-TYPE SYNTAX INTEGER { nrz(1), nrzi(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The data encoding format." ::= { pktSwchFrAEntry 10 } pktSwchFrDlcmiPollingInterval OBJECT-TYPE SYNTAX Integer32 (5..30) MAX-ACCESS read-only STATUS current DESCRIPTION "This is the number of seconds between succes- sive status enquiry messages." REFERENCE "Draft American National Standard T1.617-1991, Section D.7 Timer T391." DEFVAL { 10 } ::= { pktSwchFrAEntry 11 } pktSwchFrDlcmiFullEnquiryInterval OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of status enquiry intervals that pass before issuance of a full status enquiry mes- sage." REFERENCE "Draft American National Standard T1.617-1991, Section D.7 Counter32 N391." DEFVAL { 6 } ::= { pktSwchFrAEntry 12 } pktSwchFrDlcmiErrorThreshold OBJECT-TYPE SYNTAX Integer32 (1..10) MAX-ACCESS read-only STATUS current DESCRIPTION "This is the maximum number of unanswered Status Enquiries the equipment shall accept be- fore declaring the interface down." REFERENCE "Draft American National Standard T1.617-1991, Section D.5.1 Counter32 N392." DEFVAL { 3 } ::= { pktSwchFrAEntry 13 } pktSwchFrDlcmiMonitoredEvents OBJECT-TYPE SYNTAX Integer32 (1..10) MAX-ACCESS read-only STATUS current DESCRIPTION "This is the number of status polling intervals over which the error threshold is counted. For example, if within 'MonitoredEvents' number of events the station receives 'ErrorThreshold' number of errors, the interface is marked as down." REFERENCE "Draft American National Standard T1.617-1991, Section D.5.2 Counter32 N393." DEFVAL { 4 } ::= { pktSwchFrAEntry 14 } pktSwchFrDlciHeaderModeA OBJECT-TYPE SYNTAX INTEGER { two-octets(1), three-octets(2), four-octets(3), four-octets-nomanag(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Dlci Header length for this FR port. Option 4 means that there will be no management Dlci in the range of 1024 to 8388607. The management Dlci will be in the range of 0-15 or 991-1023. Default value: 1." ::= { pktSwchFrAEntry 15 } pktSwchFrDcdLinkFailureA OBJECT-TYPE SYNTAX INTEGER { no-Detect(2), linkFailure-Detect(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Link Failure Detection by DCD. If Link Failure detection by DCD is on - (3), when the DCD is down, the FR SW will detect it and change the FR link status from UP to DOWN. A trap of LINK DOWN will be sent to the NMS. Default: (2)." ::= { pktSwchFrAEntry 16 } pktSwchFrTxIdlesA OBJECT-TYPE SYNTAX INTEGER { no(2), yes(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter shows whether the PS will Transmit Idles between frames and control the RTS pin. Default: no(2)." ::= { pktSwchFrAEntry 17 } pktSwchFrOperationModeA OBJECT-TYPE SYNTAX INTEGER { swControl(2), hwControl(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "When H/W Control is configured, the SCC H/W will detect the change in the DCD or CTS signals and Start or Stop transmission automatically. When S/W Control is configured the S/W will decide when to start or stop the transmission. Default: swControl(2)." ::= { pktSwchFrAEntry 18 } pktSwchFrPhysInterfOptionsA OBJECT-TYPE SYNTAX INTEGER { noOption(2), dds4800bps(3), dds9600bps(4), dds19200bps(5), dds56000bos(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is the physical interface. Note that the DDS physical interface H/W does not exist in the FPS-8. It is relevant for other PS devices only. For FPS-8 only the default (noOption) should be used. Default: (2)." ::= { pktSwchFrAEntry 19 } pktSwchFrIfTable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchFrIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Frame Relay Active Port Table includes statistics and configurable objects provided by the PS that are not included in RFC 1315." ::= { pktSwchFr 4 } pktSwchFrIfEntry OBJECT-TYPE SYNTAX PktSwchFrIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in the RAD PS Frame Relay Port Active Table." INDEX { ifIndex } ::= { pktSwchFrIfTable 1 } PktSwchFrIfEntry ::= SEQUENCE { pktSwchFrIfTxBytes Counter32, pktSwchFrIfRxBytes Counter32, pktSwchFrIfTxCongDiscards Counter32, pktSwchFrIfDeTxFrames Counter32, pktSwchFrIfDeRxFrames Counter32, pktSwchFrIfFecnTxFrames Counter32, pktSwchFrIfFecnRxFrames Counter32, pktSwchFrIfBecnTxFrames Counter32, pktSwchFrIfBecnRxFrames Counter32, pktSwchFrIfCommRateViolTxFrames Counter32, pktSwchFrIfCommRateViolRxFrames Counter32, pktSwchFrIfExcessRateViolTxFrames Counter32, pktSwchFrIfExcessRateViolRxFrames Counter32, pktSwchFrIfBuffersInTxPool Integer32, pktSwchFrIfFreeBuffersInRxPool Integer32, pktSwchFrIfLmiTxFrames Counter32, pktSwchFrIfLmiRxFrames Counter32, pktSwchFrIfAnsiTxFrames Counter32, pktSwchFrIfAnsiRxFrames Counter32, pktSwchFrIfCllmTxFrames Counter32, pktSwchFrIfCllmRxFrames Counter32, pktSwchFrIfTxCongestions Counter32, pktSwchFrIfRxCongestions Counter32, pktSwchFrIfTotDlciNumber Integer32 } pktSwchFrIfTxBytes OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Tx bytes." ::= { pktSwchFrIfEntry 1 } pktSwchFrIfRxBytes OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Rx bytes." ::= { pktSwchFrIfEntry 2 } pktSwchFrIfTxCongDiscards OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames discarded because of Tx congestion." ::= { pktSwchFrIfEntry 3 } pktSwchFrIfDeTxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of DE Tx frames." ::= { pktSwchFrIfEntry 4 } pktSwchFrIfDeRxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of DE Rx frames." ::= { pktSwchFrIfEntry 5 } pktSwchFrIfFecnTxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of FECN Tx frames." ::= { pktSwchFrIfEntry 6 } pktSwchFrIfFecnRxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of FECN Tx frames." ::= { pktSwchFrIfEntry 7 } pktSwchFrIfBecnTxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of BECN Tx frames." ::= { pktSwchFrIfEntry 8 } pktSwchFrIfBecnRxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of BECN Tx frames." ::= { pktSwchFrIfEntry 9 } pktSwchFrIfCommRateViolTxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Tx committed rate violations in number of frames." ::= { pktSwchFrIfEntry 10 } pktSwchFrIfCommRateViolRxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Rx committed rate violations in number of frames." ::= { pktSwchFrIfEntry 11 } pktSwchFrIfExcessRateViolTxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Tx excess rate violations in number of frames." ::= { pktSwchFrIfEntry 12 } pktSwchFrIfExcessRateViolRxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Rx excess rate violations in number of frames." ::= { pktSwchFrIfEntry 13 } pktSwchFrIfBuffersInTxPool OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of buffers waiting for transmission." ::= { pktSwchFrIfEntry 14 } pktSwchFrIfFreeBuffersInRxPool OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of free buffers in the Rx pool." ::= { pktSwchFrIfEntry 15 } pktSwchFrIfLmiTxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of LMI Tx Frames." ::= { pktSwchFrIfEntry 16 } pktSwchFrIfLmiRxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of LMI Rx Frames." ::= { pktSwchFrIfEntry 17 } pktSwchFrIfAnsiTxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of ANSI Tx Frames." ::= { pktSwchFrIfEntry 18 } pktSwchFrIfAnsiRxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of ANSI Rx Frames." ::= { pktSwchFrIfEntry 19 } pktSwchFrIfCllmTxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of CLLM Tx Frames." ::= { pktSwchFrIfEntry 20 } pktSwchFrIfCllmRxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of CLLM Rx Frames." ::= { pktSwchFrIfEntry 21 } pktSwchFrIfTxCongestions OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Tx congestions." ::= { pktSwchFrIfEntry 22 } pktSwchFrIfRxCongestions OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Rx congestions." ::= { pktSwchFrIfEntry 23 } pktSwchFrIfTotDlciNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of DLCIs defined." ::= { pktSwchFrIfEntry 24 } pktSwchFrCircuitSTable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchFrCircuitSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Frame Relay Scratch Circuit Table includes configurable objects provided by the PS that are not included in RFC 1315." ::= { pktSwchFr 5 } pktSwchFrCircuitSEntry OBJECT-TYPE SYNTAX PktSwchFrCircuitSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in the RAD PS Frame Relay Circuit Scratch Table." INDEX { pktSwchFrCircuitIfIndexS,pktSwchFrCircuitIndexS } ::= { pktSwchFrCircuitSTable 1 } PktSwchFrCircuitSEntry ::= SEQUENCE { pktSwchFrCircuitIfIndexS Integer32, pktSwchFrCircuitIndexS Integer32, pktSwchFrCircuitDestProtS INTEGER, pktSwchFrCircuitDestIdS DisplayString, pktSwchFrCircuitBackIdS DisplayString, pktSwchFrCircuitTxCirIntervalS Integer32, pktSwchFrCircuitTxCommittedS Integer32, pktSwchFrCircuitTxExcessS Integer32, pktSwchFrCircuitRxCirIntervalS Integer32, pktSwchFrCircuitRxCommittedS Integer32, pktSwchFrCircuitRxExcessS Integer32, pktSwchFrCircuitFunnelIdS Integer32, pktSwchFrCircuitStatusS INTEGER, pktSwchFrCircuitExtendedDlciS Integer32, pktSwchFrCircuitTxPriorityS Integer32, pktSwchFrCircuitIsdnRoutIdS Integer32 } pktSwchFrCircuitIfIndexS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is the ifIndex of the circuit, according to RFC 1573." ::= { pktSwchFrCircuitSEntry 1 } pktSwchFrCircuitIndexS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This Index is the DLCI of the circuit." ::= { pktSwchFrCircuitSEntry 2 } pktSwchFrCircuitDestProtS OBJECT-TYPE SYNTAX INTEGER { x25(1), none(2), hdlc(3), async(4), multiPoint(5), rfc1490(6)} MAX-ACCESS read-write STATUS current DESCRIPTION "The protocol encapsulation, if any, on this DLCI. The MPE protocol is a proprietary RAD protocol that enables a generic HDLC device to have multiple connections over X.25 or Frame Relay." ::= { pktSwchFrCircuitSEntry 3 } pktSwchFrCircuitDestIdS OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "If the DLCI destination protocol is none or async, this field has a value of an existing DLCI or async channel, respectively. Otherwise, a value of zero is used." ::= { pktSwchFrCircuitSEntry 4 } pktSwchFrCircuitBackIdS OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The backup DLCI which is used when the current DLCI goes inactive. The destination protocol and destination id are the same as in the current DLCI" ::= { pktSwchFrCircuitSEntry 5 } pktSwchFrCircuitTxCirIntervalS OBJECT-TYPE SYNTAX Integer32 (0..10) MAX-ACCESS read-write STATUS current DESCRIPTION "The Tx CIR interval in 1/10 seconds." ::= { pktSwchFrCircuitSEntry 6 } pktSwchFrCircuitTxCommittedS OBJECT-TYPE SYNTAX Integer32 (0..65000) MAX-ACCESS read-write STATUS current DESCRIPTION "The Tx committed rate in bytes per interval." ::= { pktSwchFrCircuitSEntry 7 } pktSwchFrCircuitTxExcessS OBJECT-TYPE SYNTAX Integer32 (0..65000) MAX-ACCESS read-write STATUS current DESCRIPTION "The Tx excess in bytes per interval." ::= { pktSwchFrCircuitSEntry 8 } pktSwchFrCircuitRxCirIntervalS OBJECT-TYPE SYNTAX Integer32 (0..10) MAX-ACCESS read-write STATUS current DESCRIPTION "The Rx CIR interval in 1/10 seconds." ::= { pktSwchFrCircuitSEntry 9 } pktSwchFrCircuitRxCommittedS OBJECT-TYPE SYNTAX Integer32 (0..65000) MAX-ACCESS read-write STATUS current DESCRIPTION "The Rx committed rate in bytes per interval." ::= { pktSwchFrCircuitSEntry 10 } pktSwchFrCircuitRxExcessS OBJECT-TYPE SYNTAX Integer32 (0..65000) MAX-ACCESS read-write STATUS current DESCRIPTION "The Rx excess in bytes per interval." ::= { pktSwchFrCircuitSEntry 11 } pktSwchFrCircuitFunnelIdS OBJECT-TYPE SYNTAX Integer32 (1..200) MAX-ACCESS read-write STATUS current DESCRIPTION "The funnel ID." ::= { pktSwchFrCircuitSEntry 12 } pktSwchFrCircuitStatusS OBJECT-TYPE SYNTAX INTEGER { valid(1), createRequest(2), underCreation(3), invalid(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The status of the circuit row in the Table." ::= { pktSwchFrCircuitSEntry 13 } pktSwchFrCircuitExtendedDlciS OBJECT-TYPE SYNTAX Integer32 (0..8388607) MAX-ACCESS read-only STATUS current DESCRIPTION "The no. of the DLCI represented in 23 bits." ::= { pktSwchFrCircuitSEntry 14 } pktSwchFrCircuitTxPriorityS OBJECT-TYPE SYNTAX Integer32 (1..4) MAX-ACCESS read-write STATUS current DESCRIPTION "DLCI TX Priority level. The levels are defined in the pktSwchTxPriorityTable" ::= { pktSwchFrCircuitSEntry 15 } pktSwchFrCircuitIsdnRoutIdS OBJECT-TYPE SYNTAX Integer32 (0..200) MAX-ACCESS read-write STATUS current DESCRIPTION "ISDN destination. ID in the ISDN routing table containing the outgoing ISDN address for this DLCI. Default value: 0 for no ISDN routing ID. " ::= { pktSwchFrCircuitSEntry 16 } pktSwchFrCircuitATable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchFrCircuitAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Frame Relay Active Circuit Table includes statistics and configurable objects provided by the PS that are not included in RFC 1315." ::= { pktSwchFr 6 } pktSwchFrCircuitAEntry OBJECT-TYPE SYNTAX PktSwchFrCircuitAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in the RAD PS Frame Relay Circuit Active Table." INDEX { pktSwchFrCircuitIfIndexA,pktSwchFrCircuitIndexA } ::= { pktSwchFrCircuitATable 1 } PktSwchFrCircuitAEntry ::= SEQUENCE { pktSwchFrCircuitIfIndexA Integer32, pktSwchFrCircuitIndexA Integer32, pktSwchFrCircuitDestProtA INTEGER, pktSwchFrCircuitDestIdA DisplayString, pktSwchFrCircuitBackIdA DisplayString, pktSwchFrCircuitTxCirIntervalA Integer32, pktSwchFrCircuitTxCommittedA Integer32, pktSwchFrCircuitTxExcessA Integer32, pktSwchFrCircuitRxCirIntervalA Integer32, pktSwchFrCircuitRxCommittedA Integer32, pktSwchFrCircuitRxExcessA Integer32, pktSwchFrCircuitFunnelIdA Integer32, pktSwchFrCircuitFunnelStat DisplayString, pktSwchFrCircuitTxCongDiscards Counter32, pktSwchFrCircuitDeTxFrames Counter32, pktSwchFrCircuitDeRxFrames Counter32, pktSwchFrCircuitFecnTxFrames Counter32, pktSwchFrCircuitBecnTxFrames Counter32, pktSwchFrCircuitCommRateViolTxFrames Counter32, pktSwchFrCircuitCommRateViolRxFrames Counter32, pktSwchFrCircuitExcessRateViolTxFrames Counter32, pktSwchFrCircuitExcessRateViolRxFrames Counter32, pktSwchFrCircuitState INTEGER, pktSwchFrCircuitExtendedDlciA Integer32, pktSwchFrCircuitTxPriorityA Integer32, pktSwchFrCircuitIsdnRoutIdA Integer32 } pktSwchFrCircuitIfIndexA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is the ifIndex of the circuit, according to RFC 1573." ::= { pktSwchFrCircuitAEntry 1 } pktSwchFrCircuitIndexA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This Index is the DLCI of the circuit." ::= { pktSwchFrCircuitAEntry 2 } pktSwchFrCircuitDestProtA OBJECT-TYPE SYNTAX INTEGER { x25(1), none(2), hdlc(3), async(4), multiPoint(5), rfc1490(6)} MAX-ACCESS read-only STATUS current DESCRIPTION "The protocol encapsulation, if any, on this DLCI. The MPE protocol is a proprietary RAD protocol that enables a generic HDLC device to have multiple connections over X.25 or Frame Relay." ::= { pktSwchFrCircuitAEntry 3 } pktSwchFrCircuitDestIdA OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "If the DLCI destination protocol is none or async, this field has a value of an existing DLCI or async channel, respectively. Otherwise, a value of zero is used." ::= { pktSwchFrCircuitAEntry 4 } pktSwchFrCircuitBackIdA OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The backup DLCI which is used when the current DLCI goes inactive. The destination protocol and destination id are the same as in the current DLCI" ::= { pktSwchFrCircuitAEntry 5 } pktSwchFrCircuitTxCirIntervalA OBJECT-TYPE SYNTAX Integer32 (0..10) MAX-ACCESS read-only STATUS current DESCRIPTION "The Tx CIR interval in 1/10 seconds." ::= { pktSwchFrCircuitAEntry 6 } pktSwchFrCircuitTxCommittedA OBJECT-TYPE SYNTAX Integer32 (0..65000) MAX-ACCESS read-only STATUS current DESCRIPTION "The Tx committed rate in bytes per interval." ::= { pktSwchFrCircuitAEntry 7 } pktSwchFrCircuitTxExcessA OBJECT-TYPE SYNTAX Integer32 (0..65000) MAX-ACCESS read-only STATUS current DESCRIPTION "The Tx excess in bytes per interval." ::= { pktSwchFrCircuitAEntry 8 } pktSwchFrCircuitRxCirIntervalA OBJECT-TYPE SYNTAX Integer32 (0..10) MAX-ACCESS read-only STATUS current DESCRIPTION "The Rx CIR interval in 1/10 seconds." ::= { pktSwchFrCircuitAEntry 9 } pktSwchFrCircuitRxCommittedA OBJECT-TYPE SYNTAX Integer32 (0..65000) MAX-ACCESS read-only STATUS current DESCRIPTION "The Rx committed rate in bytes per interval." ::= { pktSwchFrCircuitAEntry 10 } pktSwchFrCircuitRxExcessA OBJECT-TYPE SYNTAX Integer32 (0..65000) MAX-ACCESS read-only STATUS current DESCRIPTION "The Rx excess in bytes per interval." ::= { pktSwchFrCircuitAEntry 11 } pktSwchFrCircuitFunnelIdA OBJECT-TYPE SYNTAX Integer32 (1..200) MAX-ACCESS read-only STATUS current DESCRIPTION "The funnel ID." ::= { pktSwchFrCircuitAEntry 12 } pktSwchFrCircuitFunnelStat OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The funnel status." ::= { pktSwchFrCircuitAEntry 13 } pktSwchFrCircuitTxCongDiscards OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames discarded because of Tx congestion." ::= { pktSwchFrCircuitAEntry 14 } pktSwchFrCircuitDeTxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of DE Tx frames." ::= { pktSwchFrCircuitAEntry 15 } pktSwchFrCircuitDeRxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of DE Rx frames." ::= { pktSwchFrCircuitAEntry 16 } pktSwchFrCircuitFecnTxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of FECN Tx frames." ::= { pktSwchFrCircuitAEntry 17 } pktSwchFrCircuitBecnTxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of BECN Tx frames." ::= { pktSwchFrCircuitAEntry 18 } pktSwchFrCircuitCommRateViolTxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Tx committed rate violations in number of frames." ::= { pktSwchFrCircuitAEntry 19 } pktSwchFrCircuitCommRateViolRxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Rx committed rate violations in number of frames." ::= { pktSwchFrCircuitAEntry 20 } pktSwchFrCircuitExcessRateViolTxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Tx excess rate violations in number of frames." ::= { pktSwchFrCircuitAEntry 21 } pktSwchFrCircuitExcessRateViolRxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Rx excess rate violations in number of frames." ::= { pktSwchFrCircuitAEntry 22 } pktSwchFrCircuitState OBJECT-TYPE SYNTAX INTEGER { new (1), noState (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the particular virtual cir- cuit is new or not." ::= { pktSwchFrCircuitAEntry 23 } pktSwchFrCircuitExtendedDlciA OBJECT-TYPE SYNTAX Integer32 (0..8388607) MAX-ACCESS read-only STATUS current DESCRIPTION "The no. of the DLCI represented in 23 bits." ::= { pktSwchFrCircuitAEntry 24 } pktSwchFrCircuitTxPriorityA OBJECT-TYPE SYNTAX Integer32 (1..4) MAX-ACCESS read-only STATUS current DESCRIPTION "DLCI TX Priority level. The levels are defined in the pktSwchTxPriorityTable" ::= { pktSwchFrCircuitAEntry 25 } pktSwchFrCircuitIsdnRoutIdA OBJECT-TYPE SYNTAX Integer32 (0..200) MAX-ACCESS read-only STATUS current DESCRIPTION "ISDN destination. ID in the ISDN routing table containing the outgoing ISDN address for this DLCI. Default value: 0 for no ISDN routing ID. " ::= { pktSwchFrCircuitAEntry 26 } pktSwchFrFunnelSTable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchFrFunnelSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Frame Relay Funnel Table defines the funnels that DLCIs may use." ::= { pktSwchFr 7 } pktSwchFrFunnelSEntry OBJECT-TYPE SYNTAX PktSwchFrFunnelSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in the RAD PS Frame Relay Funnel Table." INDEX { pktSwchFrFunnelIndexS } ::= { pktSwchFrFunnelSTable 1 } PktSwchFrFunnelSEntry ::= SEQUENCE { pktSwchFrFunnelIndexS Integer32, pktSwchFrFunnelSizeS Integer32, pktSwchFrFunnelHighWaterFramesS Integer32, pktSwchFrFunnelHighWaterBytesS Integer32, pktSwchFrFunnelGaugeTxRateS Integer32, pktSwchFrFunnelTransWindowS Integer32, pktSwchFrFunnelStatusS INTEGER } pktSwchFrFunnelIndexS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is the index of the funnel table." ::= { pktSwchFrFunnelSEntry 1 } pktSwchFrFunnelSizeS OBJECT-TYPE SYNTAX Integer32 (0..256) MAX-ACCESS read-write STATUS current DESCRIPTION "The number of frames the funnel can store internally, where each frame is 512 bytes." ::= { pktSwchFrFunnelSEntry 2 } pktSwchFrFunnelHighWaterFramesS OBJECT-TYPE SYNTAX Integer32 (0..256) MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum number of frames the funnel can hold before it expands and transmits all the data." ::= { pktSwchFrFunnelSEntry 3 } pktSwchFrFunnelHighWaterBytesS OBJECT-TYPE SYNTAX Integer32 (0..65000) MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum number of bytes the funnel can hold before it expands and transmits all the data." ::= { pktSwchFrFunnelSEntry 4 } pktSwchFrFunnelGaugeTxRateS OBJECT-TYPE SYNTAX Integer32 (0..65000) MAX-ACCESS read-write STATUS current DESCRIPTION "The outgoing data rate in bytes per window of the funnel." ::= { pktSwchFrFunnelSEntry 5 } pktSwchFrFunnelTransWindowS OBJECT-TYPE SYNTAX Integer32 (0..10) MAX-ACCESS read-write STATUS current DESCRIPTION "The transmission rate is measured during a sliding time window. This parameter defines the window in 1/10 seconds." ::= { pktSwchFrFunnelSEntry 6 } pktSwchFrFunnelStatusS OBJECT-TYPE SYNTAX INTEGER { valid(1), createRequest(2), underCreation(3), invalid(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The status of this funnel table entry. The choices are those defined in the SNMPv2 Textual Conventions for RowStatus. This will allow easy replacement of the INTEGER syntax with the RowStatus textual convention SYNTAX." ::= { pktSwchFrFunnelSEntry 7 } pktSwchFrFunnelATable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchFrFunnelAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Frame Relay Funnel Table defines the funnels that DLCIs may use." ::= { pktSwchFr 8 } pktSwchFrFunnelAEntry OBJECT-TYPE SYNTAX PktSwchFrFunnelAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in the RAD PS Frame Relay Funnel Table." INDEX { pktSwchFrFunnelIndexA } ::= { pktSwchFrFunnelATable 1 } PktSwchFrFunnelAEntry ::= SEQUENCE { pktSwchFrFunnelIndexA Integer32, pktSwchFrFunnelSizeA Integer32, pktSwchFrFunnelHighWaterFramesA Integer32, pktSwchFrFunnelHighWaterBytesA Integer32, pktSwchFrFunnelGaugeTxRateA Integer32, pktSwchFrFunnelTransWindowA Integer32 } pktSwchFrFunnelIndexA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is the index of the funnel table." ::= { pktSwchFrFunnelAEntry 1 } pktSwchFrFunnelSizeA OBJECT-TYPE SYNTAX Integer32 (0..256) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames the funnel can store internally, where each frame is 512 bytes." ::= { pktSwchFrFunnelAEntry 2 } pktSwchFrFunnelHighWaterFramesA OBJECT-TYPE SYNTAX Integer32 (0..256) MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of frames the funnel can hold before it expands and transmits all the data." ::= { pktSwchFrFunnelAEntry 3 } pktSwchFrFunnelHighWaterBytesA OBJECT-TYPE SYNTAX Integer32 (0..65000) MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of bytes the funnel can hold before it expands and transmits all the data." ::= { pktSwchFrFunnelAEntry 4 } pktSwchFrFunnelGaugeTxRateA OBJECT-TYPE SYNTAX Integer32 (0..65000) MAX-ACCESS read-only STATUS current DESCRIPTION "The outgoing data rate in bytes per window of the funnel." ::= { pktSwchFrFunnelAEntry 5 } pktSwchFrFunnelTransWindowA OBJECT-TYPE SYNTAX Integer32 (0..10) MAX-ACCESS read-only STATUS current DESCRIPTION "The transmission rate is measured during a sliding time window. This parameter defines the window in 1/10 seconds." ::= { pktSwchFrFunnelAEntry 6 } pktSwchFrDlciMapTable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchFrDlciMapEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Frame Relay Dlci mapping Table maps the Dlci numbers. For each long Dlci a short one is mapped. A long Dlci is a Dlci which contains a Dlci header of 3 or 4 bytes instead of the regular 2 bytes. The long Dlci number has values from 1024 to 8,388,607." ::= { pktSwchFr 9 } pktSwchFrDlciMapEntry OBJECT-TYPE SYNTAX PktSwchFrDlciMapEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each Dlci Map Table entry." INDEX { pktSwchFrDlciMapPort, pktSwchFrDlciMapLongDlci } ::= { pktSwchFrDlciMapTable 1 } PktSwchFrDlciMapEntry ::= SEQUENCE { pktSwchFrDlciMapPort Integer32, pktSwchFrDlciMapLongDlci Integer32, pktSwchFrDlciMapShortDlci Integer32, pktSwchFrDlciMapStatus INTEGER } pktSwchFrDlciMapPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Frame Relay port no. : 1-8 for FPS-8, 1-4 for FPS-4, 1-3 for APS, 1-6 for SPS-6, 1-12 for SPS-12." ::= { pktSwchFrDlciMapEntry 1 } pktSwchFrDlciMapLongDlci OBJECT-TYPE SYNTAX Integer32 (0..8388607) MAX-ACCESS read-only STATUS current DESCRIPTION "The Long Dlci number. For Dlci's of 4 octets, the long Dlci number has values from 1024 to 8,388,607. For Dlci's of 2 octets, the long Dlci number has values of 16-991." ::= { pktSwchFrDlciMapEntry 2 } pktSwchFrDlciMapShortDlci OBJECT-TYPE SYNTAX Integer32 (0..1023) MAX-ACCESS read-only STATUS current DESCRIPTION "The Short Dlci number. Legal values: 0 - 1023." ::= { pktSwchFrDlciMapEntry 3 } pktSwchFrDlciMapStatus OBJECT-TYPE SYNTAX INTEGER { valid(1), createRequest(2), underCreation(3), invalid(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The status of the map row in the Table. The only value which can be set is: createRequest. This value is set when a new long dlci is created." ::= { pktSwchFrDlciMapEntry 4 } pktSwchMpe OBJECT IDENTIFIER ::= { radPS 9 } pktSwchMpeSTable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchMpeSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The MPE Table defines Scratch configuration parameters for the MPE protocol." ::= { pktSwchMpe 1 } pktSwchMpeSEntry OBJECT-TYPE SYNTAX PktSwchMpeSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in the MPE Table." INDEX { pktSwchMpeLinkNumberS } ::= { pktSwchMpeSTable 1 } PktSwchMpeSEntry ::= SEQUENCE { pktSwchMpeLinkNumberS Integer32, pktSwchMpeInactivityS Integer32, pktSwchMpeX25FacilitiesS Integer32, pktSwchMpeLocSubAddr1S Integer32, pktSwchMpeLocSubAddr2S Integer32, pktSwchMpeFlwCtrlDurS Integer32, pktSwchMpeFlwCtrlOptS Integer32, pktSwchMpeFlwCtrlBufS Integer32, pktSwchMpeInternalClkS INTEGER } pktSwchMpeLinkNumberS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The link number with which this entry is associated. This value corresponds to pktSwchPhyInterfaceNumber. There is an entry for each link for which the pktSwchPhyInterfaceProtocol is MPE." ::= { pktSwchMpeSEntry 1 } pktSwchMpeInactivityS OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "The amount of time in minutes of inactivity that will cause the session to disconnect." ::= { pktSwchMpeSEntry 2 } pktSwchMpeX25FacilitiesS OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "This specifies the X.25 facilities. The value is a sum of values (powers of two), where each value in the sum represents an option. The values that may be included in the sum and their meanings are: 0 No options 1 Packet size negotiation 2 Window size negotiation 4 Reverse charge." ::= { pktSwchMpeSEntry 3 } pktSwchMpeLocSubAddr1S OBJECT-TYPE SYNTAX Integer32 (1..99) MAX-ACCESS read-write STATUS current DESCRIPTION "The first local subaddress." ::= { pktSwchMpeSEntry 4 } pktSwchMpeLocSubAddr2S OBJECT-TYPE SYNTAX Integer32 (1..99) MAX-ACCESS read-write STATUS current DESCRIPTION "The second local subaddress." ::= { pktSwchMpeSEntry 5 } pktSwchMpeFlwCtrlDurS OBJECT-TYPE SYNTAX Integer32 (0..200) MAX-ACCESS read-write STATUS current DESCRIPTION "The duration in 50 milliseconds of a hardware flow control signal. Default is 0" ::= { pktSwchMpeSEntry 6 } pktSwchMpeFlwCtrlOptS OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-write STATUS current DESCRIPTION "This specifies the type of flow control of the MPE link. The value is a sum of values (powers of two), where each value in the sum represents an option. The values that may be included in the sum and their meanings are: 0 No flow control 1 CTS flow control 2 Clock flow control." ::= { pktSwchMpeSEntry 7 } pktSwchMpeFlwCtrlBufS OBJECT-TYPE SYNTAX Integer32 (0..200) MAX-ACCESS read-write STATUS current DESCRIPTION "The number of buffers that will be allocated for the MPE link." ::= { pktSwchMpeSEntry 8 } pktSwchMpeInternalClkS OBJECT-TYPE SYNTAX INTEGER { r2400bps (1), r4800bps (2), r9600bps (3), r14400bps(4), r19200bps(5), r38400bps(6), r48Kbps (7), r56Kbps (8), r64Kbps (9), r128Kbps (10), r256Kbps (11), r384Kbps (12), r504Kbps (13), r768Kbps (14), r1008Kbps(15), r1466Kbps(16), r2016Kbps(17), external(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "The baud rate of the internal clock." ::= { pktSwchMpeSEntry 9 } pktSwchMpeATable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchMpeAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The MPE Table defines Active configuration parameters for the MPE protocol." ::= { pktSwchMpe 2 } pktSwchMpeAEntry OBJECT-TYPE SYNTAX PktSwchMpeAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in the MPE Table." INDEX { pktSwchMpeLinkNumberA } ::= { pktSwchMpeATable 1 } PktSwchMpeAEntry ::= SEQUENCE { pktSwchMpeLinkNumberA Integer32, pktSwchMpeInactivityA Integer32, pktSwchMpeX25FacilitiesA Integer32, pktSwchMpeLocSubAddr1A Integer32, pktSwchMpeLocSubAddr2A Integer32, pktSwchMpeFlwCtrlDurA Integer32, pktSwchMpeFlwCtrlOptA Integer32, pktSwchMpeFlwCtrlBufA Integer32, pktSwchMpeInternalClkA INTEGER, pktSwchMpeCtsStatus INTEGER } pktSwchMpeLinkNumberA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The link number with which this entry is associated. This value corresponds to pktSwchPhyInterfaceNumber. There is an entry for each link for which the pktSwchPhyInterfaceProtocol is MPE." ::= { pktSwchMpeAEntry 1 } pktSwchMpeInactivityA OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of time in minutes of inactivity that will cause the session to disconnect." ::= { pktSwchMpeAEntry 2 } pktSwchMpeX25FacilitiesA OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "This specifies the X.25 facilities. The value is a sum of values (powers of two), where each value in the sum represents an option. The values that may be included in the sum and their meanings are: 0 No options 1 Packet size negotiation 2 Window size negotiation 4 Reverse charge." ::= { pktSwchMpeAEntry 3 } pktSwchMpeLocSubAddr1A OBJECT-TYPE SYNTAX Integer32 (1..99) MAX-ACCESS read-only STATUS current DESCRIPTION "The first local subaddress." ::= { pktSwchMpeAEntry 4 } pktSwchMpeLocSubAddr2A OBJECT-TYPE SYNTAX Integer32 (1..99) MAX-ACCESS read-only STATUS current DESCRIPTION "The second local subaddress." ::= { pktSwchMpeAEntry 5 } pktSwchMpeFlwCtrlDurA OBJECT-TYPE SYNTAX Integer32 (0..200) MAX-ACCESS read-only STATUS current DESCRIPTION "The duration in 50 milliseconds of a hardware flow control signal." ::= { pktSwchMpeAEntry 6 } pktSwchMpeFlwCtrlOptA OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "This specifies the type of flow control of the MPE link. The value is a sum of values (powers of two), where each value in the sum represents an option. The values that may be included in the sum and their meanings are: 0 No flow control 1 CTS flow control 2 Clock flow control." ::= { pktSwchMpeAEntry 7 } pktSwchMpeFlwCtrlBufA OBJECT-TYPE SYNTAX Integer32 (0..200) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of buffers that will be allocated for the MPE link." ::= { pktSwchMpeAEntry 8 } pktSwchMpeInternalClkA OBJECT-TYPE SYNTAX INTEGER { r2400bps (1), r4800bps (2), r9600bps (3), r14400bps(4), r19200bps(5), r38400bps(6), r48Kbps (7), r56Kbps (8), r64Kbps (9), r128Kbps (10), r256Kbps (11), r384Kbps (12), r504Kbps (13), r768Kbps (14), r1008Kbps(15), r1466Kbps(16), r2016Kbps(17), external(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "The baud rate of the internal clock." ::= { pktSwchMpeAEntry 9 } pktSwchMpeCtsStatus OBJECT-TYPE SYNTAX INTEGER { off(2), on(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The CTS status." ::= { pktSwchMpeAEntry 10 } pktSwchMpeAidSTable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchMpeAidSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The AID Table defines Scratch configuration parameters for the logical connections (Address Id)." ::= { pktSwchMpe 3 } pktSwchMpeAidSEntry OBJECT-TYPE SYNTAX PktSwchMpeAidSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in the MPE Table." INDEX { ifIndex, pktSwchMpeAddressIdS } ::= { pktSwchMpeAidSTable 1 } PktSwchMpeAidSEntry ::= SEQUENCE { pktSwchMpeAddressIdS Integer32, pktSwchMpeAidMainTypeS INTEGER, pktSwchMpeAidMainIdS Integer32, pktSwchMpeAidMainSubIdS Integer32, pktSwchMpeAidBackupTypeS INTEGER, pktSwchMpeAidBackupIdS Integer32, pktSwchMpeAidBackupSubIdS Integer32, pktSwchMpeAidStatusS INTEGER } pktSwchMpeAddressIdS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The Address Id (AID) with which this entry is associated." ::= { pktSwchMpeAidSEntry 1 } pktSwchMpeAidMainTypeS OBJECT-TYPE SYNTAX INTEGER { x25Svc(1), x25Pvc(2), fr(3), innerCom(4), notActive(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "The protocol with which the AID is communicating." ::= { pktSwchMpeAidSEntry 2 } pktSwchMpeAidMainIdS OBJECT-TYPE SYNTAX Integer32 (0..200) MAX-ACCESS read-write STATUS current DESCRIPTION "The link number of the protocol with which the AID is communicating. The link number of the protocol with which the AID is communicating. For X.25 SVC this number is Any Autocall ID (Pre-defined) , values: 1..200 For X.25 PVC this number is a local PVC that its source link has already been set to the current link with a prefix of N. values: 1..200 For FR this number is any Frame Relay link number (Pre-defined), values: 1..12 For Inner communication this number is an HDLC or MPE link number (Pre-defined), values: 1..12 For notActive this number is 0." ::= { pktSwchMpeAidSEntry 3 } pktSwchMpeAidMainSubIdS OBJECT-TYPE SYNTAX Integer32 (0..991) MAX-ACCESS read-write STATUS current DESCRIPTION "The DLCI with which the AID is communicating. Sub ID is used only when Type is Frame Relay or Inner Comm. The DLCI or destination AID with which the current AID is communicating. If type is: Frame Relay PVC: Sub ID must be an existing DLCI, 16-991. (The DLCI's destination protocol has to be predefined to MPE). If type is: Inner Communication: In case of an HDLC link, Sub ID must be 0. In case of an MPE link, Sub ID must be in AID permitted range. For notActive this number is 0." ::= { pktSwchMpeAidSEntry 4 } pktSwchMpeAidBackupTypeS OBJECT-TYPE SYNTAX INTEGER { x25Svc(1), x25Pvc(2), fr(3), innerCom(4), notActive(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "The protocol with which the AID is communicating on the backup." ::= { pktSwchMpeAidSEntry 5 } pktSwchMpeAidBackupIdS OBJECT-TYPE SYNTAX Integer32 (0..200) MAX-ACCESS read-write STATUS current DESCRIPTION "The link number of the protocol with which the AID is communicating on the backup. The link number of the protocol with which the AID is communicating. For X.25 SVC this number is Any Autocall ID (Pre-defined) , values: 1..200 For X.25 PVC this number is a local PVC that its source link has already been set to the current link with a prefix of N. values: 1..200 For FR this number is any Frame Relay link number (Pre-defined), values: 1..12 For Inner communication this number is an HDLC or MPE link number (Pre-defined), values: 1..12 For notActive this number is 0." ::= { pktSwchMpeAidSEntry 6 } pktSwchMpeAidBackupSubIdS OBJECT-TYPE SYNTAX Integer32 (0..991) MAX-ACCESS read-write STATUS current DESCRIPTION "The DLCI with which the AID is communicating. Sub ID is used only when Type is Frame Relay or Inner Comm. The DLCI or destination AID with which the current AID is communicating. If type is: Frame Relay PVC: Sub ID must be an existing DLCI, 16-991. (The DLCI's destination protocol has to be predefined to MPE). If type is: Inner Communication: In case of an HDLC link, Sub ID must be 0. In case of an MPE link, Sub ID must be in AID permitted range. For notActive this number is 0." ::= { pktSwchMpeAidSEntry 7 } pktSwchMpeAidStatusS OBJECT-TYPE SYNTAX INTEGER { valid(1), createRequest(2), underCreation(3), invalid(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The status of this Address Id table entry." ::= { pktSwchMpeAidSEntry 8 } pktSwchMpeAidATable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchMpeAidAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The AID Table defines Active configuration parameters for the logical connections (Address Id)." ::= { pktSwchMpe 4 } pktSwchMpeAidAEntry OBJECT-TYPE SYNTAX PktSwchMpeAidAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in the MPE Table." INDEX { ifIndex, pktSwchMpeAddressIdA } ::= { pktSwchMpeAidATable 1 } PktSwchMpeAidAEntry ::= SEQUENCE { pktSwchMpeAddressIdA Integer32, pktSwchMpeAidMainTypeA INTEGER, pktSwchMpeAidMainIdA Integer32, pktSwchMpeAidMainSubIdA Integer32, pktSwchMpeAidBackupTypeA INTEGER, pktSwchMpeAidBackupIdA Integer32, pktSwchMpeAidBackupSubIdA Integer32, pktSwchMpeAidConn INTEGER, pktSwchMpeAidFlwCtrl INTEGER } pktSwchMpeAddressIdA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The Address Id (AID) with which this entry is associated." ::= { pktSwchMpeAidAEntry 1 } pktSwchMpeAidMainTypeA OBJECT-TYPE SYNTAX INTEGER { x25Svc(1), x25Pvc(2), fr(3), innerCom(4), notActive(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "The protocol with which the AID is communicating." ::= { pktSwchMpeAidAEntry 2 } pktSwchMpeAidMainIdA OBJECT-TYPE SYNTAX Integer32 (0..200) MAX-ACCESS read-only STATUS current DESCRIPTION "The link number of the protocol with which the AID is communicating. The link number of the protocol with which the AID is communicating. For X.25 SVC this number is Any Autocall ID (Pre-defined) , values: 1..200 For X.25 PVC this number is a local PVC that its source link has already been set to the current link with a prefix of N. values: 1..200 For FR this number is any Frame Relay link number (Pre-defined), values: 1..12 For Inner communication this number is an HDLC or MPE link number (Pre-defined), values: 1..12 For notActive this number is 0." ::= { pktSwchMpeAidAEntry 3 } pktSwchMpeAidMainSubIdA OBJECT-TYPE SYNTAX Integer32 (0..991) MAX-ACCESS read-only STATUS current DESCRIPTION "The DLCI with which the AID is communicating. Sub ID is used only when Type is Frame Relay or Inner Comm. The DLCI or destination AID with which the current AID is communicating. If type is: Frame Relay PVC: Sub ID must be an existing DLCI, 16-991. (The DLCI's destination protocol has to be predefined to MPE). If type is: Inner Communication: In case of an HDLC link, Sub ID must be 0. In case of an MPE link, Sub ID must be in AID permitted range. For notActive this number is 0." ::= { pktSwchMpeAidAEntry 4 } pktSwchMpeAidBackupTypeA OBJECT-TYPE SYNTAX INTEGER { x25Svc(1), x25Pvc(2), fr(3), innerCom(4), notActive(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "The protocol with which the AID is communicating on the backup." ::= { pktSwchMpeAidAEntry 5 } pktSwchMpeAidBackupIdA OBJECT-TYPE SYNTAX Integer32 (0..200) MAX-ACCESS read-only STATUS current DESCRIPTION "The link number of the protocol with which the AID is communicating on the backup. The link number of the protocol with which the AID is communicating. For X.25 SVC this number is Any Autocall ID (Pre-defined) , values: 1..200 For X.25 PVC this number is a local PVC that its source link has already been set to the current link with a prefix of N. values: 1..200 For FR this number is any Frame Relay link number (Pre-defined), values: 1..12 For Inner communication this number is an HDLC or MPE link number (Pre-defined), values: 1..12 For notActive this number is 0." ::= { pktSwchMpeAidAEntry 6 } pktSwchMpeAidBackupSubIdA OBJECT-TYPE SYNTAX Integer32 (0..991) MAX-ACCESS read-only STATUS current DESCRIPTION "The DLCI with which the AID is communicating. Sub ID is used only when Type is Frame Relay or Inner Comm. The DLCI or destination AID with which the current AID is communicating. If type is: Frame Relay PVC: Sub ID must be an existing DLCI, 16-991. (The DLCI's destination protocol has to be predefined to MPE). If type is: Inner Communication: In case of an HDLC link, Sub ID must be 0. In case of an MPE link, Sub ID must be in AID permitted range. For notActive this number is 0." ::= { pktSwchMpeAidAEntry 7 } pktSwchMpeAidConn OBJECT-TYPE SYNTAX INTEGER { disconnect(1), connect(2), pvc(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The connectivity status of the AID." ::= { pktSwchMpeAidAEntry 8 } pktSwchMpeAidFlwCtrl OBJECT-TYPE SYNTAX INTEGER { inactive(1), active(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Flow Control status of the AID." ::= { pktSwchMpeAidAEntry 9 } -- The PS Slip Group contains Slip Scratch and Active Tables, -- which contain configuration for Slip links pktSwchSlip OBJECT IDENTIFIER ::= { radPS 10 } pktSwchSlipSTable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchSlipSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Scratch Slip Table contains configuration information for Slip links" ::= { pktSwchSlip 1 } pktSwchSlipSEntry OBJECT-TYPE SYNTAX PktSwchSlipSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in the RAD Slip Table." INDEX { pktSwchSlipLinkNumberS } ::= { pktSwchSlipSTable 1 } PktSwchSlipSEntry ::= SEQUENCE { pktSwchSlipLinkNumberS Integer32, pktSwchSlipSpeedS INTEGER, pktSwchSlipFCOptionS Integer32, pktSwchSlipStopBitsS INTEGER, pktSwchSlipBitPerCharS Integer32, pktSwchSlipParityS INTEGER, pktSwchSlipIpAddressS IpAddress, pktSwchSlipIpMaskS IpAddress, pktSwchSlipDefEncapsTypeS INTEGER, pktSwchSlipDefDestinationS DisplayString } pktSwchSlipLinkNumberS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The link number with which this entry is associated. This value corresponds to pktSwchPhyInterfaceIfIndex. There is an entry for each link for which the pktSwchPhyInterfaceProtocol is Slip." ::= { pktSwchSlipSEntry 1 } pktSwchSlipSpeedS OBJECT-TYPE SYNTAX INTEGER { s110bps (1), s300bps (2), s1200bps (3), s600bps (4), s75bps (5), s150bps (6), s2400bps (12), s4800bps (13), s9600bps (14), s19200bps (15), s38400bps (19), s57600bps (20), s115200bps(21) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter determines the rate of data transmission to and from the DTE." ::= { pktSwchSlipSEntry 2 } pktSwchSlipFCOptionS OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION " The flow control options 0 - No HARDWARE flow control 1..254 - Timer value (in 50ms intervals), when timer expires, flow control stops 255 - The timer is not used" ::= { pktSwchSlipSEntry 3 } pktSwchSlipStopBitsS OBJECT-TYPE SYNTAX INTEGER { one (1), two (2), oneAndHalf(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This entry indicates the number of stop bits per character supported by the PAD. The options are either (1) one stop bit, (2) two stop bits, or (3) 1.5 stop bits." ::= { pktSwchSlipSEntry 4 } pktSwchSlipBitPerCharS OBJECT-TYPE SYNTAX Integer32 (5..8) MAX-ACCESS read-write STATUS current DESCRIPTION "The number of data bits per character supported by the Slip link." ::= { pktSwchSlipSEntry 5 } pktSwchSlipParityS OBJECT-TYPE SYNTAX INTEGER { space(1), mark(2), even(3), odd(4), none(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This entry selects the type of parity to be checked and or generated by the PAD when radSPSProfileParTreat is a value other than 255. The options are (1) space parity, (2) mark parity, (3) even parity, (4) odd parity, or (255) no parity." ::= { pktSwchSlipSEntry 6 } pktSwchSlipIpAddressS OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS deprecated DESCRIPTION "The IP address connected to this Slip port. This variable is used when an automatic connection is done by the IP Routing." ::= { pktSwchSlipSEntry 7 } pktSwchSlipIpMaskS OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS deprecated DESCRIPTION "The IP mask. This variable is used when an automatic connection by the IP Routing is done." ::= { pktSwchSlipSEntry 8 } pktSwchSlipDefEncapsTypeS OBJECT-TYPE SYNTAX INTEGER { slip (1), x25SVC (2), x25PVC (3), frameRelay (4), hdlc (5), none (255) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Destination protocol of this Slip port. This variable is used when a direct connection without IP Routing is done." ::= { pktSwchSlipSEntry 9 } pktSwchSlipDefDestinationS OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Default destination for this Slip port. This variable is used when a direct connection without IP Routing is done. Possible values: Default : Not Used. X.25 PVC: Port:LCN or a pre defined PVC number X.25 SVC: X.25 Addr or cid followed by a predefined Call ID number Frame Relay: Port:DLCI HDLC: HDLC Port Number SLIP: SLIP Channel Number" ::= { pktSwchSlipSEntry 10 } -- The active slip table -- pktSwchSlipATable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchSlipAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Active Slip Table contains configuration information for Slip links" ::= { pktSwchSlip 2 } pktSwchSlipAEntry OBJECT-TYPE SYNTAX PktSwchSlipAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in the RAD Slip Table." INDEX { pktSwchSlipLinkNumberA } ::= { pktSwchSlipATable 1 } PktSwchSlipAEntry ::= SEQUENCE { pktSwchSlipLinkNumberA Integer32, pktSwchSlipSpeedA INTEGER, pktSwchSlipFCOptionA Integer32, pktSwchSlipStopBitsA INTEGER, pktSwchSlipBitPerCharA Integer32, pktSwchSlipParityA INTEGER, pktSwchSlipIpAddressA IpAddress, pktSwchSlipIpMaskA IpAddress, pktSwchSlipDefEncapsTypeA INTEGER, pktSwchSlipDefDestinationA DisplayString } pktSwchSlipLinkNumberA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The link number with which this entry is associated. This value corresponds to pktSwchPhyInterfaceIfIndex. There is an entry for each link for which the pktSwchPhyInterfaceProtocol is Slip." ::= { pktSwchSlipAEntry 1 } pktSwchSlipSpeedA OBJECT-TYPE SYNTAX INTEGER { s110bps (1), s300bps (2), s1200bps (3), s600bps (4), s75bps (5), s150bps (6), s2400bps (12), s4800bps (13), s9600bps (14), s19200bps (15), s38400bps (19), s57600bps (20), s115200bps(21) } MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter determines the rate of data transmission to and from the DTE." ::= { pktSwchSlipAEntry 2 } pktSwchSlipFCOptionA OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION " The flow control options 0 - No HARDWARE flow control 1..254 - Timer value (in 50ms intervals), when timer expires, flow control stops 255 - The timer is not used" ::= { pktSwchSlipAEntry 3 } pktSwchSlipStopBitsA OBJECT-TYPE SYNTAX INTEGER { one (1), two (2), oneAndHalf(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This entry indicates the number of stop bits per character supported by the PAD. The options are either (1) one stop bit, (2) two stop bits, or (3) 1.5 stop bits." ::= { pktSwchSlipAEntry 4 } pktSwchSlipBitPerCharA OBJECT-TYPE SYNTAX Integer32 (5..8) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of data bits per character supported by the Slip link." ::= { pktSwchSlipAEntry 5 } pktSwchSlipParityA OBJECT-TYPE SYNTAX INTEGER { space(1), mark(2), even(3), odd(4), none(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This entry selects the type of parity to be checked and or generated by the PAD when radSPSProfileParTreat is a value other than 255. The options are (1) space parity, (2) mark parity, (3) even parity, (4) odd parity, or (255) no parity." ::= { pktSwchSlipAEntry 6 } pktSwchSlipIpAddressA OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The IP address connected to this Slip port." ::= { pktSwchSlipAEntry 7 } pktSwchSlipIpMaskA OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The IP mask." ::= { pktSwchSlipAEntry 8 } pktSwchSlipDefEncapsTypeA OBJECT-TYPE SYNTAX INTEGER { slip (1), x25SVC (2), x25PVC (3), frameRelay (4), hdlc (5), none (255) } MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Destination protocol of this Slip port." ::= { pktSwchSlipAEntry 9 } pktSwchSlipDefDestinationA OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Default destination for this Slip port. This variable is used when a direct connection without IP Routing is done. Possible values: Default : Not Used. X.25 PVC: Port:LCN or a pre defined PVC number X.25 SVC: X.25 Addr or cid followed by a predefined Call ID number Frame Relay: Port:DLCI HDLC: HDLC Port Number SLIP: SLIP Channel Number" ::= { pktSwchSlipAEntry 10 } pktSwchSna OBJECT IDENTIFIER ::= { radPS 11} pktSwchSnaSDLCLinkTableS OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchSnaSDLCLinkEntryS MAX-ACCESS not-accessible STATUS current DESCRIPTION "The SDLC Link Table defines the SDLC links configured on the PS." ::= { pktSwchSna 1 } pktSwchSnaSDLCLinkEntryS OBJECT-TYPE SYNTAX PktSwchSnaSDLCLinkEntryS MAX-ACCESS not-accessible STATUS current DESCRIPTION "SDLC Link Entry defines the contents of each link in the SDLC Link Table." INDEX {ifIndex } ::= { pktSwchSnaSDLCLinkTableS 1 } PktSwchSnaSDLCLinkEntryS ::= SEQUENCE { pktSwchSnaSDLCLinkTypeS INTEGER, pktSwchSnaSDLCLinkPUSharedS INTEGER, pktSwchSnaSDLCLinkDuplexPhyS INTEGER, pktSwchSnaSDLCLinkflagsS Integer32, pktSwchSnaSDLCLinkDuplexS INTEGER, pktSwchSnaSDLCLinkClockS INTEGER, pktSwchSnaSDLCLinkNRZS INTEGER } pktSwchSnaSDLCLinkTypeS OBJECT-TYPE SYNTAX INTEGER{ primary(1), secondary(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter identifies whether this link operates as TPAD(Primary) or HPAD(Secondary) SDLC device." ::= { pktSwchSnaSDLCLinkEntryS 1 } pktSwchSnaSDLCLinkPUSharedS OBJECT-TYPE SYNTAX INTEGER { yes(1), no (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter defines whether the link participates with more than one PU or not." ::= { pktSwchSnaSDLCLinkEntryS 2 } pktSwchSnaSDLCLinkDuplexPhyS OBJECT-TYPE SYNTAX INTEGER { half (1), full (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter describes whether the physical level of the SDLC line is half or full duplex." ::= { pktSwchSnaSDLCLinkEntryS 3 } pktSwchSnaSDLCLinkflagsS OBJECT-TYPE SYNTAX Integer32 (1..15) MAX-ACCESS read-write STATUS current DESCRIPTION "Number of flags between frames." ::= { pktSwchSnaSDLCLinkEntryS 4 } pktSwchSnaSDLCLinkDuplexS OBJECT-TYPE SYNTAX INTEGER { twoWayAlter (1), twoWaySimul (2) } MAX-ACCESS read-write STATUS current DESCRIPTION " This parameter shows wether the link level is Two Way Alternate or Two Way Simultaneous." ::= { pktSwchSnaSDLCLinkEntryS 5 } pktSwchSnaSDLCLinkClockS OBJECT-TYPE SYNTAX INTEGER { r2400bps(1), r4800bps(2), r9600Bps(3), r14400bps(4), r19200bps(5), r38400bps(6), r48000bps(7), r56000bps(8), r64000bps(9), r128000bps(10), r256000bps(11), r384000bps(12), r504000bps(13), r768000bps(14), r1008000bps(15), r1466000bps(16), r2016000bps(17), external(255) } MAX-ACCESS read-write STATUS current DESCRIPTION " This parameter defines the link clock rate " ::= { pktSwchSnaSDLCLinkEntryS 6 } pktSwchSnaSDLCLinkNRZS OBJECT-TYPE SYNTAX INTEGER { nrzFlags(1), nrziFlags(2), nrzIdle(3), nrziIdle(4) } MAX-ACCESS read-write STATUS current DESCRIPTION " This parameter describes the following combinations of NRZ, NRZI with FLAGS or IDLE between frames: Legal values: 1 - NRZ with FLAGs between frames. RTS is Constant 2 - NRZI with FLAGs between frames. RTS is Constant. 3 - NRZ with IDLE between frames. RTS is Controlled. 4 - NRZI with IDLE between frames. RTS is Controlled." ::={ pktSwchSnaSDLCLinkEntryS 7} pktSwchSnaSDLCLinkTableA OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchSnaSDLCLinkEntryA MAX-ACCESS not-accessible STATUS current DESCRIPTION "The SDLC Link Table defines the SDLC links configured on the SPS." ::= { pktSwchSna 2 } pktSwchSnaSDLCLinkEntryA OBJECT-TYPE SYNTAX PktSwchSnaSDLCLinkEntryA MAX-ACCESS not-accessible STATUS current DESCRIPTION "SDLC Link Entry defines the contents of each link in the SDLC Link Table." INDEX {ifIndex } ::= { pktSwchSnaSDLCLinkTableA 1 } PktSwchSnaSDLCLinkEntryA ::= SEQUENCE { pktSwchSnaSDLCLinkTypeA INTEGER, pktSwchSnaSDLCLinkPUSharedA INTEGER, pktSwchSnaSDLCLinkDuplexPhyA INTEGER, pktSwchSnaSDLCLinkflagsA Integer32, pktSwchSnaSDLCLinkDuplexA INTEGER, pktSwchSnaSDLCLinkClockA INTEGER, pktSwchSnaSDLCLinkNRZA INTEGER, pktSwchSnaSDLCLinkStatFrames Counter32, pktSwchSnaSDLCLinkStatErrors Counter32, pktSwchSnaSDLCLinkStatInvalidAddresses Counter32, pktSwchSnaSDLCLinkStatShortFrames Counter32 } pktSwchSnaSDLCLinkTypeA OBJECT-TYPE SYNTAX INTEGER{ primary(1), secondary(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter identifies whether this link operates as TPAD(Primary) or HPAD(Secondary) SDLC device." ::= { pktSwchSnaSDLCLinkEntryA 1 } pktSwchSnaSDLCLinkPUSharedA OBJECT-TYPE SYNTAX INTEGER { yes(1), no (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter defines whether the link participates with more than one PU or not." ::= { pktSwchSnaSDLCLinkEntryA 2 } pktSwchSnaSDLCLinkDuplexPhyA OBJECT-TYPE SYNTAX INTEGER { half (1), full (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter describes whether the physical level of the SDLC line is half or full duplex." ::= { pktSwchSnaSDLCLinkEntryA 3 } pktSwchSnaSDLCLinkflagsA OBJECT-TYPE SYNTAX Integer32 (1..15) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of flags between frames." ::= { pktSwchSnaSDLCLinkEntryA 4 } pktSwchSnaSDLCLinkDuplexA OBJECT-TYPE SYNTAX INTEGER { twoWayAlter (1), twoWaySimul (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " This parameter shows wether the link level is Two Way Alternate or Two Way Simultaneous." ::= { pktSwchSnaSDLCLinkEntryA 5 } pktSwchSnaSDLCLinkClockA OBJECT-TYPE SYNTAX INTEGER { r2400bps(1), r4800bps(2), r9600Bps(3), r14400bps(4), r19200bps(5), r38400bps(6), r48000bps(7), r56000bps(8), r64000bps(9), r128000bps(10), r256000bps(11), r384000bps(12), r504000bps(13), r768000bps(14), r1008000bps(15), r1466000bps(16), r2016000bps(17), external(255) } MAX-ACCESS read-only STATUS current DESCRIPTION " This parameter defines the link clock rate." ::= { pktSwchSnaSDLCLinkEntryA 6 } pktSwchSnaSDLCLinkNRZA OBJECT-TYPE SYNTAX INTEGER { nrzFlags(1), nrziFlags(2), nrzIdle(3), nrziIdle(4) } MAX-ACCESS read-only STATUS current DESCRIPTION " This parameter describes the following combinations of NRZ, NRZI with FLAGS or IDLE between frames: Legal values: 1 - NRZ with FLAGs between frames. RTS is Constant 2 - NRZI with FLAGs between frames. RTS is Constant. 3 - NRZ with IDLE between frames. RTS is Controlled. 4 - NRZI with IDLE between frames. RTS is Controlled." ::={ pktSwchSnaSDLCLinkEntryA 7} pktSwchSnaSDLCLinkStatFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames received or transmitted via this link " ::= { pktSwchSnaSDLCLinkEntryA 8 } pktSwchSnaSDLCLinkStatErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of error frames received. " ::= { pktSwchSnaSDLCLinkEntryA 9} pktSwchSnaSDLCLinkStatInvalidAddresses OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames with wrong address received by this link. " ::= { pktSwchSnaSDLCLinkEntryA 10} pktSwchSnaSDLCLinkStatShortFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of short frames received by this link. " ::= { pktSwchSnaSDLCLinkEntryA 11} pktSwchSnaPUTableS OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchSnaPUEntryS MAX-ACCESS not-accessible STATUS current DESCRIPTION "The SDLC PU table defines the PUs configured on the PS." ::= { pktSwchSna 3 } pktSwchSnaPUEntryS OBJECT-TYPE SYNTAX PktSwchSnaPUEntryS MAX-ACCESS not-accessible STATUS current DESCRIPTION "SDLC PU Entry defines the contents of each PU in the SDLC PU Table." INDEX {pktSwchSnaPUNumberS} ::= { pktSwchSnaPUTableS 1 } PktSwchSnaPUEntryS ::= SEQUENCE { pktSwchSnaPUNumberS Integer32, pktSwchSnaPUXIDProcessingS INTEGER, pktSwchSnaPUEnableS INTEGER, pktSwchSnaPULinkATypeS INTEGER, pktSwchSnaPULinkARoleS INTEGER, pktSwchSnaPULinkBTypeS INTEGER, pktSwchSnaPULinkBRoleS INTEGER, pktSwchSnaPUEntryStatusS INTEGER } pktSwchSnaPUNumberS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter defines an identifier associated with the PU Entry which is unique within the SPS" ::= { pktSwchSnaPUEntryS 1} pktSwchSnaPUXIDProcessingS OBJECT-TYPE SYNTAX INTEGER { localXid(1), end2EndSupNoAct(2), end2EndNoSupNoAct(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Exchange Identification (XID) processing. The following values are legal: 1 - Local XID handling 2 - End-to-End XID handling, Support for NON-Activation XID 3 - End-to-End XID handling, NO Support for NON-Activation XID" ::= { pktSwchSnaPUEntryS 2} pktSwchSnaPUEnableS OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The PU runs or not at this specific time" ::= { pktSwchSnaPUEntryS 3} pktSwchSnaPULinkATypeS OBJECT-TYPE SYNTAX INTEGER { sdlc(1), x25Qllc(2), frameRelayLLC2(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The PU link A type." ::= { pktSwchSnaPUEntryS 4} pktSwchSnaPULinkARoleS OBJECT-TYPE SYNTAX INTEGER { primary(1), secondary(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The PU role for link A. Note that the role of an SDLC PU may not be changed. It is defined by the SDLC Link Type." ::= { pktSwchSnaPUEntryS 5} pktSwchSnaPULinkBTypeS OBJECT-TYPE SYNTAX INTEGER { sdlc(1), x25Qllc(2), frameRelayLLC2(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The PU partner link B type" ::= { pktSwchSnaPUEntryS 6} pktSwchSnaPULinkBRoleS OBJECT-TYPE SYNTAX INTEGER { primary(1), secondary(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The PU role for link B. Note that the role of an SDLC PU may not be changed. It is defined by the SDLC Link Type." ::= { pktSwchSnaPUEntryS 7} pktSwchSnaPUEntryStatusS OBJECT-TYPE SYNTAX INTEGER { valid(1), createRequest(2), underCreation(3), invalid(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The status of this PU table entry. This Set request will fail if there are any conflicts between any of of the parameter values in any of the tables comprising this PU definition " ::= {pktSwchSnaPUEntryS 8} pktSwchSnaPUTableA OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchSnaPUEntryA MAX-ACCESS not-accessible STATUS current DESCRIPTION "The SDLC PU table defines the PUs configured on the PS." ::= { pktSwchSna 4 } pktSwchSnaPUEntryA OBJECT-TYPE SYNTAX PktSwchSnaPUEntryA MAX-ACCESS not-accessible STATUS current DESCRIPTION "SDLC PU Entry defines the contents of each PU in the SDLC PU Table." INDEX {pktSwchSnaPUNumberA} ::= { pktSwchSnaPUTableA 1 } PktSwchSnaPUEntryA ::= SEQUENCE { pktSwchSnaPUNumberA Integer32, pktSwchSnaPUXIDProcessingA INTEGER, pktSwchSnaPUEnableA INTEGER, pktSwchSnaPULinkATypeA INTEGER, pktSwchSnaPULinkARoleA INTEGER, pktSwchSnaPULinkBTypeA INTEGER, pktSwchSnaPULinkBRoleA INTEGER } pktSwchSnaPUNumberA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter defines an identifier associated with the PU Entry which is unique within the SPS" ::= { pktSwchSnaPUEntryA 1} pktSwchSnaPUXIDProcessingA OBJECT-TYPE SYNTAX INTEGER { localXid(1), end2EndSupNoAct(2), end2EndNoSupNoAct(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The PU XID Processing" ::= { pktSwchSnaPUEntryA 2} pktSwchSnaPUEnableA OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The PU runs or not at this specific time" ::= { pktSwchSnaPUEntryA 3} pktSwchSnaPULinkATypeA OBJECT-TYPE SYNTAX INTEGER { sdlc(1), x25Qllc(2), frameRelayLLC2(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The PU link type" ::= { pktSwchSnaPUEntryA 4} pktSwchSnaPULinkARoleA OBJECT-TYPE SYNTAX INTEGER { primary(1), secondary(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The PU role for link A" ::= { pktSwchSnaPUEntryA 5} pktSwchSnaPULinkBTypeA OBJECT-TYPE SYNTAX INTEGER { sdlc(1), x25Qllc(2), frameRelayLLC2(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The PU partner link type" ::= { pktSwchSnaPUEntryA 6} pktSwchSnaPULinkBRoleA OBJECT-TYPE SYNTAX INTEGER { primary(1), secondary(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The PU role for link B" ::= { pktSwchSnaPUEntryA 7} pktSwchSnaPUSdlcTableS OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchSnaPUSdlcEntryS MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines links for PUs running on SDLC link " ::= { pktSwchSna 5 } pktSwchSnaPUSdlcEntryS OBJECT-TYPE SYNTAX PktSwchSnaPUSdlcEntryS MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines parameters of a link for a PU running on an SDLC link " INDEX {pktSwchSnaPUSdlcNumberS , pktSwchSnaPUSdlcSideS } ::= { pktSwchSnaPUSdlcTableS 1 } PktSwchSnaPUSdlcEntryS ::= SEQUENCE { pktSwchSnaPUSdlcNumberS Integer32, pktSwchSnaPUSdlcSideS INTEGER, pktSwchSnaPUSdlcAddressS OCTET STRING, pktSwchSnaPUSdlcIfIndexS Integer32, pktSwchSnaPUSdlcIdBlkS OCTET STRING, pktSwchSnaPUSdlcIdNumS OCTET STRING, pktSwchSnaPUSdlcMaxPiuSizeS Integer32, pktSwchSnaPUSdlcTxWindowS Integer32, pktSwchSnaPUSdlcGrpAddressS OCTET STRING, pktSwchSnaPUSdlcPollTimerS Integer32, pktSwchSnaPUSdlcXIDInitiationS INTEGER, pktSwchSnaPUSdlcEntryStatusS INTEGER } pktSwchSnaPUSdlcNumberS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter defines an identifier associated with the PU Entry SDLC side, which is unique within the SPS" ::= { pktSwchSnaPUSdlcEntryS 1} pktSwchSnaPUSdlcSideS OBJECT-TYPE SYNTAX INTEGER { sideA(1), sideB(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Is this side A or side B of the PU definition " ::= { pktSwchSnaPUSdlcEntryS 2} pktSwchSnaPUSdlcAddressS OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) MAX-ACCESS read-write STATUS current DESCRIPTION "SNA SDLC PU address. Range: 0x00-0xFE " ::= { pktSwchSnaPUSdlcEntryS 3} pktSwchSnaPUSdlcIfIndexS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "ifIndex of the SDLC link" ::= { pktSwchSnaPUSdlcEntryS 4} pktSwchSnaPUSdlcIdBlkS OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..2)) MAX-ACCESS read-write STATUS current DESCRIPTION "Part of the IBM device ID (the full ID is defined by the IDBLK and the IDNUM). The Idblk is required for secondary PU with Local XID handling. Up to 3 Hexadecimal digits, format: 0X XX." ::= {pktSwchSnaPUSdlcEntryS 5} pktSwchSnaPUSdlcIdNumS OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..3)) MAX-ACCESS read-write STATUS current DESCRIPTION "Second part of the IBM device ID (the full ID is defined by the IDBLK and the IDNUM). The Idnum is required for secondary PU with Local XID handling. Up to 5 Hexadecimal digits, format: 0X XX XX." ::= {pktSwchSnaPUSdlcEntryS 6} pktSwchSnaPUSdlcMaxPiuSizeS OBJECT-TYPE SYNTAX Integer32 (137..7642) MAX-ACCESS read-write STATUS current DESCRIPTION "Maximum Path Information Size" ::= { pktSwchSnaPUSdlcEntryS 7} pktSwchSnaPUSdlcTxWindowS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Window Size(in frames) used when sending from the SPS. Range: 1-7." ::= { pktSwchSnaPUSdlcEntryS 8} pktSwchSnaPUSdlcGrpAddressS OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) MAX-ACCESS read-write STATUS current DESCRIPTION "SNA Group address used by the SPS when sending polls (TPAD ONLY). Range: 0x00-0xFE" ::= { pktSwchSnaPUSdlcEntryS 9} pktSwchSnaPUSdlcPollTimerS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Time in between polls in 50 millisecond increments (TPAD ONLY). Range: 1-65535." ::= { pktSwchSnaPUSdlcEntryS 10} pktSwchSnaPUSdlcXIDInitiationS OBJECT-TYPE SYNTAX INTEGER{ notInitiate(1), initiate(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter is not applicable for PU with Local XID handling. Legal values: 1 - Do not initiate an XID message. 2 - Initiate an XID message to SDLC." ::= { pktSwchSnaPUSdlcEntryS 11} pktSwchSnaPUSdlcEntryStatusS OBJECT-TYPE SYNTAX INTEGER { valid(1), underCreation(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The status of this PU Sdlc table entry. In order to save this entry, set status to valid. An underCreation value is set by the Agent when this entry is updated." ::= {pktSwchSnaPUSdlcEntryS 12} pktSwchSnaPUSdlcTableA OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchSnaPUSdlcEntryA MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines links for PUs running on an SDLC link " ::= { pktSwchSna 6 } pktSwchSnaPUSdlcEntryA OBJECT-TYPE SYNTAX PktSwchSnaPUSdlcEntryA MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines parameters of link for PU running on an SDLC link " INDEX {pktSwchSnaPUSdlcNumberA , pktSwchSnaPUSdlcSideA } ::= { pktSwchSnaPUSdlcTableA 1 } PktSwchSnaPUSdlcEntryA ::= SEQUENCE { pktSwchSnaPUSdlcNumberA Integer32, pktSwchSnaPUSdlcSideA INTEGER, pktSwchSnaPUSdlcAddressA OCTET STRING, pktSwchSnaPUSdlcIfIndexA Integer32, pktSwchSnaPUSdlcIdBlkA OCTET STRING, pktSwchSnaPUSdlcIdNumA OCTET STRING, pktSwchSnaPUSdlcMaxPiuSizeA Integer32, pktSwchSnaPUSdlcTxWindowA Integer32, pktSwchSnaPUSdlcGrpAddressA OCTET STRING, pktSwchSnaPUSdlcPollTimerA Integer32, pktSwchSnaPUSdlcXIDInitiationA INTEGER } pktSwchSnaPUSdlcNumberA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter defines an identifier associated with the PU Entry SDLC side, which is unique within the SPS" ::= { pktSwchSnaPUSdlcEntryA 1} pktSwchSnaPUSdlcSideA OBJECT-TYPE SYNTAX INTEGER { sideA(1), sideB(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Is this side A or side B of the PU definition " ::= { pktSwchSnaPUSdlcEntryA 2} pktSwchSnaPUSdlcAddressA OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) MAX-ACCESS read-only STATUS current DESCRIPTION "SNA SDLC PU address. Range: 0x00-0xFE." ::= { pktSwchSnaPUSdlcEntryA 3} pktSwchSnaPUSdlcIfIndexA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "ifIndex of the SDLC link" ::= { pktSwchSnaPUSdlcEntryA 4} pktSwchSnaPUSdlcIdBlkA OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..2)) MAX-ACCESS read-only STATUS current DESCRIPTION "Part of the IBM device ID (the full ID is defined by the IDBLK and the IDNUM). The Idblk is required for secondary PU with Local XID handling. Up to 3 Hexadecimal digits, format: 0X XX." ::= {pktSwchSnaPUSdlcEntryA 5} pktSwchSnaPUSdlcIdNumA OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..3)) MAX-ACCESS read-only STATUS current DESCRIPTION "Second part of the IBM device ID (the full ID is defined by the IDBLK and the IDNUM). The Idnum is required for secondary PU with Local XID handling. Up to 5 Hexadecimal digits, format: 0X XX XX." ::= {pktSwchSnaPUSdlcEntryA 6} pktSwchSnaPUSdlcMaxPiuSizeA OBJECT-TYPE SYNTAX Integer32 (137..7642) MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum Path Information Size" ::= {pktSwchSnaPUSdlcEntryA 7} pktSwchSnaPUSdlcTxWindowA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Window Size(in frames) used when sending from the SPS. Range: 1-7." ::= { pktSwchSnaPUSdlcEntryA 8} pktSwchSnaPUSdlcGrpAddressA OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) MAX-ACCESS read-only STATUS current DESCRIPTION "SNA Group address used by the SPS when sending polls (TPAD ONLY). Range: 0x00-0xFE." ::= { pktSwchSnaPUSdlcEntryA 9} pktSwchSnaPUSdlcPollTimerA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Time in between polls in 50 millisecond increments (TPAD ONLY). Range: 1-65535." ::= { pktSwchSnaPUSdlcEntryA 10} pktSwchSnaPUSdlcXIDInitiationA OBJECT-TYPE SYNTAX INTEGER{ notInitiate(1), initiate(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter is not applicable for PU with Local XID handling. Legal values: 1 - Do not initiate an XID message. 2 - Initiate an XID message to SDLC." ::= { pktSwchSnaPUSdlcEntryA 11} pktSwchSnaPUSdlcStatTable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchSnaPUSdlcStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Shows Link Statistics for PUs running on an SDLC link " ::= { pktSwchSna 7 } pktSwchSnaPUSdlcStatEntry OBJECT-TYPE SYNTAX PktSwchSnaPUSdlcStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Shows Link Statistics for PUs running on an SDLC link " INDEX {pktSwchSnaPUSdlcStatNumber , pktSwchSnaPUSdlcStatSide } ::= { pktSwchSnaPUSdlcStatTable 1 } PktSwchSnaPUSdlcStatEntry ::= SEQUENCE { pktSwchSnaPUSdlcStatNumber Integer32, pktSwchSnaPUSdlcStatSide INTEGER, pktSwchSnaPUSdlcStatOctetsIn Counter32, pktSwchSnaPUSdlcStatOctetsOut Counter32, pktSwchSnaPUSdlcStatIFramesIn Counter32, pktSwchSnaPUSdlcStatIFramesOut Counter32, pktSwchSnaPUSdlcStatRRFramesIn Counter32, pktSwchSnaPUSdlcStatRRFramesOut Counter32, pktSwchSnaPUSdlcStatRNRFramesIn Counter32, pktSwchSnaPUSdlcStatRNRFramesOut Counter32, pktSwchSnaPUSdlcStatXIDsIn Counter32, pktSwchSnaPUSdlcStatXIDsOut Counter32, pktSwchSnaPUSdlcStatTESTsIn Counter32, pktSwchSnaPUSdlcStatTESTsOut Counter32, pktSwchSnaPUSdlcStatREJsIn Counter32, pktSwchSnaPUSdlcStatREJsOut Counter32, pktSwchSnaPUSdlcStatFRMRsIn Counter32, pktSwchSnaPUSdlcStatFRMRsOut Counter32, pktSwchSnaPUSdlcStatDISCsIn Counter32, pktSwchSnaPUSdlcStatDISCsOut Counter32, pktSwchSnaPUSdlcStatUAsIn Counter32, pktSwchSnaPUSdlcStatUAsOut Counter32, pktSwchSnaPUSdlcStatDMsIn Counter32, pktSwchSnaPUSdlcStatDMsOut Counter32, pktSwchSnaPUSdlcStatSNRMsIn Counter32, pktSwchSnaPUSdlcStatSNRMsOut Counter32, pktSwchSnaPUSdlcStatRetransmitsIn Counter32, pktSwchSnaPUSdlcStatRetransmitsOut Counter32, pktSwchSnaPUSdlcUpperState INTEGER, pktSwchSnaPUSdlcLowerState INTEGER, pktSwchSnaPUSdlcStatNRMStatus INTEGER, pktSwchSnaPUSdlcStatFlowCtlStatus INTEGER } pktSwchSnaPUSdlcStatNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter defines an identifier associated with the PU Entry SDLC side statistics, which is unique within the SPS" ::= { pktSwchSnaPUSdlcStatEntry 1} pktSwchSnaPUSdlcStatSide OBJECT-TYPE SYNTAX INTEGER { sideA(1), sideB(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Is this side A or side B of the PU definition " ::= { pktSwchSnaPUSdlcStatEntry 2} pktSwchSnaPUSdlcStatOctetsIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPUSdlcStatEntry 3} pktSwchSnaPUSdlcStatOctetsOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPUSdlcStatEntry 4} pktSwchSnaPUSdlcStatIFramesIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPUSdlcStatEntry 5} pktSwchSnaPUSdlcStatIFramesOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPUSdlcStatEntry 6} pktSwchSnaPUSdlcStatRRFramesIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPUSdlcStatEntry 7} pktSwchSnaPUSdlcStatRRFramesOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPUSdlcStatEntry 8} pktSwchSnaPUSdlcStatRNRFramesIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPUSdlcStatEntry 9} pktSwchSnaPUSdlcStatRNRFramesOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPUSdlcStatEntry 10} pktSwchSnaPUSdlcStatXIDsIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPUSdlcStatEntry 11} pktSwchSnaPUSdlcStatXIDsOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPUSdlcStatEntry 12} pktSwchSnaPUSdlcStatTESTsIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPUSdlcStatEntry 13} pktSwchSnaPUSdlcStatTESTsOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPUSdlcStatEntry 14} pktSwchSnaPUSdlcStatREJsIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPUSdlcStatEntry 15} pktSwchSnaPUSdlcStatREJsOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPUSdlcStatEntry 16} pktSwchSnaPUSdlcStatFRMRsIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPUSdlcStatEntry 17} pktSwchSnaPUSdlcStatFRMRsOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPUSdlcStatEntry 18} pktSwchSnaPUSdlcStatDISCsIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPUSdlcStatEntry 19} pktSwchSnaPUSdlcStatDISCsOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPUSdlcStatEntry 20} pktSwchSnaPUSdlcStatUAsIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPUSdlcStatEntry 21} pktSwchSnaPUSdlcStatUAsOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPUSdlcStatEntry 22} pktSwchSnaPUSdlcStatDMsIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPUSdlcStatEntry 23} pktSwchSnaPUSdlcStatDMsOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPUSdlcStatEntry 24} pktSwchSnaPUSdlcStatSNRMsIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPUSdlcStatEntry 25} pktSwchSnaPUSdlcStatSNRMsOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPUSdlcStatEntry 26} pktSwchSnaPUSdlcStatRetransmitsIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPUSdlcStatEntry 27} pktSwchSnaPUSdlcStatRetransmitsOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPUSdlcStatEntry 28} pktSwchSnaPUSdlcUpperState OBJECT-TYPE SYNTAX INTEGER { unbound(1), bindPending(2), unbindPend(3), idle(4), unattached(5), attachPend(6), detachPend(7), udqosPending(8), outconPend(9), inconPending(10), connResPend(11), dataxfer(12), userResetPend(13), provRstPend(14), rstResPend(15), discon8Pend(16), discon9Pend(17), discon11Pend(18), discon12Pend(19), discon13Pend(20), subsBindPnd(21), noChange(22) } MAX-ACCESS read-only STATUS current DESCRIPTION "The internal DLPI state of the connection." ::= { pktSwchSnaPUSdlcStatEntry 29} pktSwchSnaPUSdlcLowerState OBJECT-TYPE SYNTAX INTEGER { linkClosed(1), disconnected(2), linkOpening(3), disconnecting(4), frmrSent(5), linkOpened(6), localBusy(7), rejection(8), checkpointing(9), cpLocalBusy(10), cpRejection(11), resetting(12), remoteBusy(13), lBusyRBusy(14), rejLBusy(15), rejRBusy(16), cpRejLBusy(17), cpClearing(18), cpRejClr(19), rejLbusyRbusy(20), frmrReceived(21), programError(22), noChange(23) } MAX-ACCESS read-only STATUS current DESCRIPTION "The internal SDLC state of the connection." ::= { pktSwchSnaPUSdlcStatEntry 30} pktSwchSnaPUSdlcStatNRMStatus OBJECT-TYPE SYNTAX INTEGER {sync(1),notSync(2)} MAX-ACCESS read-only STATUS current DESCRIPTION "This variable indicates if the link is in Normal Response Mode or not." ::= { pktSwchSnaPUSdlcStatEntry 31} pktSwchSnaPUSdlcStatFlowCtlStatus OBJECT-TYPE SYNTAX INTEGER {noRNR(1),txFlow(2), rxFlow(3), rxAndTx(4)} MAX-ACCESS read-only STATUS current DESCRIPTION "This variable indicates the flow control status of the PU interface." ::= { pktSwchSnaPUSdlcStatEntry 32} pktSwchSnaPUSX25QllcTableS OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchSnaPUX25QllcEntryS MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines links for PUs running on a QLLC link " ::= {pktSwchSna 8 } pktSwchSnaPUX25QllcEntryS OBJECT-TYPE SYNTAX PktSwchSnaPUX25QllcEntryS MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines parameters for PU side running on SDLC link " INDEX {pktSwchSnaPUX25QllcNumberS , pktSwchSnaPUX25QllcSideS } ::= { pktSwchSnaPUSX25QllcTableS 1 } PktSwchSnaPUX25QllcEntryS ::= SEQUENCE { pktSwchSnaPUX25QllcNumberS Integer32, pktSwchSnaPUX25QllcSideS INTEGER, pktSwchSnaPUX25QllcIdBlkS OCTET STRING, pktSwchSnaPUX25QllcIdNumS OCTET STRING, pktSwchSnaPUX25QllcXIDInitS INTEGER, pktSwchSnaPUX25QllcMaxPiuSizeS Integer32, pktSwchSnaPUX25QllcStationAddressS OCTET STRING, pktSwchSnaPUX25QllcInPasswordS DisplayString, pktSwchSnaPUX25QllcSubAddressS Integer32, pktSwchSnaPUX25QllcAutoCallS INTEGER, pktSwchSnaPUX25QllcCalledAddressS OCTET STRING, pktSwchSnaPUX25QllcCallUserDataFacilitiesS DisplayString, pktSwchSnaPUX25QllcEntryStatusS INTEGER } pktSwchSnaPUX25QllcNumberS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter defines an identifier associated with the PU Entry X25\QLLC side, which is unique within the SPS" ::= {pktSwchSnaPUX25QllcEntryS 1} pktSwchSnaPUX25QllcSideS OBJECT-TYPE SYNTAX INTEGER { sideA(1), sideB(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Is there side A or B of the PU connection " ::= {pktSwchSnaPUX25QllcEntryS 2} pktSwchSnaPUX25QllcIdBlkS OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..2)) MAX-ACCESS read-write STATUS current DESCRIPTION "Part of the IBM device ID (the full ID is defined by the IDBLK and the IDNUM). The Idblk is required for secondary PU with Local XID handling. Up to 3 Hexadecimal digits, format: 0X XX." ::= {pktSwchSnaPUX25QllcEntryS 3} pktSwchSnaPUX25QllcIdNumS OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..3)) MAX-ACCESS read-write STATUS current DESCRIPTION "Second part of the IBM device ID (the full ID is defined by the IDBLK and the IDNUM). The Idnum is required for secondary PU with Local XID handling. Up to 5 Hexadecimal digits, format: 0X XX XX." ::= {pktSwchSnaPUX25QllcEntryS 4} pktSwchSnaPUX25QllcXIDInitS OBJECT-TYPE SYNTAX INTEGER { notInitiate(1), initiate(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter is not applicable for PU with Local XID handling. Legal values: 1 - Do not initiate an XID message. 2 - Initiate an XID message to QLLC." ::= {pktSwchSnaPUX25QllcEntryS 5} pktSwchSnaPUX25QllcMaxPiuSizeS OBJECT-TYPE SYNTAX Integer32 (137..7642) MAX-ACCESS read-write STATUS current DESCRIPTION "Maximum Path Information Size" ::= { pktSwchSnaPUX25QllcEntryS 6} pktSwchSnaPUX25QllcStationAddressS OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) MAX-ACCESS read-write STATUS current DESCRIPTION "QLLC PU Link Station Address. Range: 0x01-0xFE. This parameter is applicable only for PU with End-to-End XID handling, Support for NON-Activation XID." ::= {pktSwchSnaPUX25QllcEntryS 7} pktSwchSnaPUX25QllcInPasswordS OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) MAX-ACCESS read-write STATUS current DESCRIPTION "A field matched with the call user data in call request packets for purposes of security and correlation." ::= {pktSwchSnaPUX25QllcEntryS 8} pktSwchSnaPUX25QllcSubAddressS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The X.25 Sub-address associated with the PU Entry for routing incoming call indications. Range: 0-99." ::= {pktSwchSnaPUX25QllcEntryS 9} pktSwchSnaPUX25QllcAutoCallS OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter indicates whether the SPS automatically initiates an X.25 call request or not." ::= {pktSwchSnaPUX25QllcEntryS 10} pktSwchSnaPUX25QllcCalledAddressS OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..15)) MAX-ACCESS read-write STATUS current DESCRIPTION "The destination x.25 DTE address to which the SPS calls. Used with AutoCall only." ::= {pktSwchSnaPUX25QllcEntryS 11} pktSwchSnaPUX25QllcCallUserDataFacilitiesS OBJECT-TYPE SYNTAX DisplayString (SIZE(1..60)) MAX-ACCESS read-write STATUS current DESCRIPTION "The X.25 facilities and Call User Data which the SPS uses on outgoing calls. AutoCall only. Up to 60 Hexa-Decimal digits. Each pair of digits represents a BYTE. BYTE-0 BYTE-1 BYTE-2 ... BYTE-29 (30 Bytes maximum) BYTE-0 for X.25 Facilities. BYTE-1 to BYTE-29 for Call User Data. Facilities (BYTE-0) format: PW (Hexa-Decimal), where: X.25 L3 Packet Size Negotiation : [P=1 YES] [P=0 NO]. X.25 L3 Packet Window Negotiation : [W=1 YES] [W=0 NO]. Legal Values for Facilities BYTE-0 : 10, 01, 11, 00 (Hex). ATTENTION: a. Total number of digits in this field must be EVEN. b. To clear this field, enter blanks or 00." ::= {pktSwchSnaPUX25QllcEntryS 12} pktSwchSnaPUX25QllcEntryStatusS OBJECT-TYPE SYNTAX INTEGER { valid(1), underCreation(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The status of this PU Qllc table entry. In order to save this entry, set status to valid. An underCreation value is set by the Agent when this entry is updated." ::= {pktSwchSnaPUX25QllcEntryS 13} pktSwchSnaPUX25QllcTableA OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchSnaPUX25QllcEntryA MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines links for PUs running on a QLLC link " ::= { pktSwchSna 9 } pktSwchSnaPUX25QllcEntryA OBJECT-TYPE SYNTAX PktSwchSnaPUX25QllcEntryA MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines parameters for PU side running on an SDLC link " INDEX {pktSwchSnaPUX25QllcNumberA , pktSwchSnaPUX25QllcSideA} ::= { pktSwchSnaPUX25QllcTableA 1 } PktSwchSnaPUX25QllcEntryA ::= SEQUENCE { pktSwchSnaPUX25QllcNumberA Integer32, pktSwchSnaPUX25QllcSideA INTEGER, pktSwchSnaPUX25QllcIdBlkA OCTET STRING, pktSwchSnaPUX25QllcIdNumA OCTET STRING, pktSwchSnaPUX25QllcXIDInitA INTEGER, pktSwchSnaPUX25QllcMaxPiuSizeA Integer32, pktSwchSnaPUX25QllcStationAddressA OCTET STRING, pktSwchSnaPUX25QllcInPasswordA DisplayString, pktSwchSnaPUX25QllcSubAddressA Integer32, pktSwchSnaPUX25QllcAutoCallA INTEGER, pktSwchSnaPUX25QllcCalledAddressA OCTET STRING, pktSwchSnaPUX25QllcCallUserDataFacilitiesA DisplayString } pktSwchSnaPUX25QllcNumberA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter defines an identifier associated with the PU Entry X25\QLLC side, which is unique within the SPS" ::= {pktSwchSnaPUX25QllcEntryA 1} pktSwchSnaPUX25QllcSideA OBJECT-TYPE SYNTAX INTEGER { sideA(1), sideB(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Is there side A or B of the PU connection " ::= {pktSwchSnaPUX25QllcEntryA 2} pktSwchSnaPUX25QllcIdBlkA OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..2)) MAX-ACCESS read-only STATUS current DESCRIPTION "Part of the IBM device ID (the full ID is defined by the IDBLK and the IDNUM). The Idblk is required for secondary PU with Local XID handling. Up to 3 Hexadecimal digits, format: 0X XX." ::= {pktSwchSnaPUX25QllcEntryA 3} pktSwchSnaPUX25QllcIdNumA OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..3)) MAX-ACCESS read-only STATUS current DESCRIPTION "Second part of the IBM device ID (the full ID is defined by the IDBLK and the IDNUM). The Idnum is required for secondary PU with Local XID handling. Up to 5 Hexadecimal digits, format: 0X XX XX." ::= {pktSwchSnaPUX25QllcEntryA 4} pktSwchSnaPUX25QllcXIDInitA OBJECT-TYPE SYNTAX INTEGER { notInitiate(1), initiate(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter is not applicable for PU with Local XID handling. Legal values: 1 - Do not initiate an XID message. 2 - Initiate an XID message to QLLC." ::= {pktSwchSnaPUX25QllcEntryA 5} pktSwchSnaPUX25QllcMaxPiuSizeA OBJECT-TYPE SYNTAX Integer32 (137..7642) MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum Path Information Size" ::= { pktSwchSnaPUX25QllcEntryA 6} pktSwchSnaPUX25QllcStationAddressA OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) MAX-ACCESS read-only STATUS current DESCRIPTION "QLLC PU Link Station Address. Range: 0x01-0xFE. This parameter is applicable only for PU with End-to-End XID handling, Support for NON-Activation XID." ::= {pktSwchSnaPUX25QllcEntryA 7} pktSwchSnaPUX25QllcInPasswordA OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "A field matched with the call user data in call request packets for purposes of security and correlation." ::= {pktSwchSnaPUX25QllcEntryA 8} pktSwchSnaPUX25QllcSubAddressA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The X.25 Sub-address associated with the PU Entry for routing incoming call indications. Range: 0-99." ::= {pktSwchSnaPUX25QllcEntryA 9} pktSwchSnaPUX25QllcAutoCallA OBJECT-TYPE SYNTAX INTEGER{ yes(1), no(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates whether the SPS automatically initiates an X.25 call request or not." ::= {pktSwchSnaPUX25QllcEntryA 10} pktSwchSnaPUX25QllcCalledAddressA OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "The destination x.25 DTE address to which the SPS calls. Used with AutoCall only." ::= {pktSwchSnaPUX25QllcEntryA 11} pktSwchSnaPUX25QllcCallUserDataFacilitiesA OBJECT-TYPE SYNTAX DisplayString (SIZE(1..60)) MAX-ACCESS read-only STATUS current DESCRIPTION "The X.25 facilities and Call User Data which the SPS uses on outgoing calls. AutoCall only. Up to 60 Hexa-Decimal digits. Each pair of digits represents a BYTE. BYTE-0 BYTE-1 BYTE-2 ... BYTE-29 (30 Bytes maximum) BYTE-0 for X.25 Facilities. BYTE-1 to BYTE-29 for Call User Data. Facilities (BYTE-0) format: PW (Hexa-Decimal), where: X.25 L3 Packet Size Negotiation : [P=1 YES] [P=0 NO]. X.25 L3 Packet Window Negotiation : [W=1 YES] [W=0 NO]. Legal Values for Facilities BYTE-0 : 10, 01, 11, 00 (Hex). ATTENTION: a. Total number of digits in this field must be EVEN. b. To clear this field, enter blanks or 00." ::= {pktSwchSnaPUX25QllcEntryA 12} pktSwchSnaPUX25QllcStatTable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchSnaPUX25QllcStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Shows link statistics for PUs running on a QLLC link " ::= { pktSwchSna 10 } pktSwchSnaPUX25QllcStatEntry OBJECT-TYPE SYNTAX PktSwchSnaPUX25QllcStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Shows link statistics for PUs running on a QLLC link " INDEX {pktSwchSnaPUX25QllcStatNumber , pktSwchSnaPUX25QllcStatSide} ::= { pktSwchSnaPUX25QllcStatTable 1 } PktSwchSnaPUX25QllcStatEntry ::= SEQUENCE { pktSwchSnaPUX25QllcStatNumber Integer32, pktSwchSnaPUX25QllcStatSide INTEGER, pktSwchSnaPUX25QllcStatlink Integer32, pktSwchSnaPUX25QllcStatDataPacketsIn Counter32, pktSwchSnaPUX25QllcStatDataPacketsOut Counter32, pktSwchSnaPUX25QllcStatQSMPacketsIn Counter32, pktSwchSnaPUX25QllcStatQSMPacketsOut Counter32, pktSwchSnaPUX25QllcStatQDMPacketsIn Counter32, pktSwchSnaPUX25QllcStatQDMPacketsOut Counter32, pktSwchSnaPUX25QllcStatXIDPacketsIn Counter32, pktSwchSnaPUX25QllcStatXIDPacketsOut Counter32, pktSwchSnaPUX25QllcStatQDISCPacketsIn Counter32, pktSwchSnaPUX25QllcStatQDISCPacketsOut Counter32, pktSwchSnaPUX25QllcStatCallPacketsIn Counter32, pktSwchSnaPUX25QllcStatCallPacketsOut Counter32, pktSwchSnaPUX25QllcStatClearPacketsIn Counter32, pktSwchSnaPUX25QllcStatClearPacketsOut Counter32, pktSwchSnaPUX25QllcStatCallAcceptsIn Counter32, pktSwchSnaPUX25QllcStatCallAcceptsOut Counter32, pktSwchSnaPUX25QllcStatUpperState INTEGER, pktSwchSnaPUX25QllcStatLowerState INTEGER, pktSwchSnaPUX25QllcStatNRMStatus INTEGER, pktSwchSnaPUX25QllcStatFlowCtlStatus INTEGER } pktSwchSnaPUX25QllcStatNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter defines an identifier associated with the PU Entry X25\QLLC side, which is unique within the SPS" ::= {pktSwchSnaPUX25QllcStatEntry 1} pktSwchSnaPUX25QllcStatSide OBJECT-TYPE SYNTAX INTEGER { sideA(1), sideB(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Is there side A or B of the PU connection " ::= {pktSwchSnaPUX25QllcStatEntry 2} pktSwchSnaPUX25QllcStatlink OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The Link on which the Qllc conversation is conducted. If there is no conversation the variable will be 0." ::= {pktSwchSnaPUX25QllcStatEntry 3} pktSwchSnaPUX25QllcStatDataPacketsIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPUX25QllcStatEntry 4 } pktSwchSnaPUX25QllcStatDataPacketsOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPUX25QllcStatEntry 5 } pktSwchSnaPUX25QllcStatQSMPacketsIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPUX25QllcStatEntry 6 } pktSwchSnaPUX25QllcStatQSMPacketsOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPUX25QllcStatEntry 7 } pktSwchSnaPUX25QllcStatQDMPacketsIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPUX25QllcStatEntry 8 } pktSwchSnaPUX25QllcStatQDMPacketsOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPUX25QllcStatEntry 9 } pktSwchSnaPUX25QllcStatXIDPacketsIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPUX25QllcStatEntry 10 } pktSwchSnaPUX25QllcStatXIDPacketsOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPUX25QllcStatEntry 11 } pktSwchSnaPUX25QllcStatQDISCPacketsIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPUX25QllcStatEntry 12 } pktSwchSnaPUX25QllcStatQDISCPacketsOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPUX25QllcStatEntry 13 } pktSwchSnaPUX25QllcStatCallPacketsIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPUX25QllcStatEntry 14 } pktSwchSnaPUX25QllcStatCallPacketsOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPUX25QllcStatEntry 15 } pktSwchSnaPUX25QllcStatClearPacketsIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPUX25QllcStatEntry 16 } pktSwchSnaPUX25QllcStatClearPacketsOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPUX25QllcStatEntry 17 } pktSwchSnaPUX25QllcStatCallAcceptsIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPUX25QllcStatEntry 18 } pktSwchSnaPUX25QllcStatCallAcceptsOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPUX25QllcStatEntry 19 } pktSwchSnaPUX25QllcStatUpperState OBJECT-TYPE SYNTAX INTEGER { unbound(1), bindPending(2), unbindPend(3), idle(4), unattached(5), attachPend(6), detachPend(7), udqosPending(8), outconPend(9), inconPending(10), connResPend(11), dataxfer(12), userResetPend(13), provRstPend(14), rstResPend(15), discon8Pend(16), discon9Pend(17), discon11Pend(18), discon12Pend(19), discon13Pend(20), subsBindPnd(21), noChange(22) } MAX-ACCESS read-only STATUS current DESCRIPTION "The internal DLPI state of the connection." ::= { pktSwchSnaPUX25QllcStatEntry 20 } pktSwchSnaPUX25QllcStatLowerState OBJECT-TYPE SYNTAX INTEGER { linkClosed(1), disconnected(2), linkOpening(3), disconnecting(4), frmrSent(5), linkOpened(6), localBusy(7), rejection(8), checkpointing(9), cpLocalBusy(10), cpRejection(11), resetting(12), remoteBusy(13), lBusyRBusy(14), rejLBusy(15), rejRBusy(16), cpRejLBusy(17), cpClearing(18), cpRejClr(19), rejLbusyRbusy(20), frmrReceived(21), programError(22), noChange(23) } MAX-ACCESS read-only STATUS current DESCRIPTION "The internal QLLC state of the connection." ::= { pktSwchSnaPUX25QllcStatEntry 21 } pktSwchSnaPUX25QllcStatNRMStatus OBJECT-TYPE SYNTAX INTEGER {sync(1),notSync(2)} MAX-ACCESS read-only STATUS current DESCRIPTION "This variable indicates if the link is in Normal Response Mode or not." ::= { pktSwchSnaPUX25QllcStatEntry 22 } pktSwchSnaPUX25QllcStatFlowCtlStatus OBJECT-TYPE SYNTAX INTEGER {noRNR(1),txFlow(2), rxFlow(3), rxAndTx(4)} MAX-ACCESS read-only STATUS current DESCRIPTION "This variable indicates the flow control status of the PU interface." ::= { pktSwchSnaPUX25QllcStatEntry 23 } pktSwchSnaPULlc2FrTableS OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchSnaPULlc2FrEntryS MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines LLC2/Frame Relay/RFC1490 Protocol Interface of SPS SNA PU entity. " ::= { pktSwchSna 11 } pktSwchSnaPULlc2FrEntryS OBJECT-TYPE SYNTAX PktSwchSnaPULlc2FrEntryS MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines parameters for PU LLC2 Protocol Interface over Frame Relay Protocol using RFC 1490." INDEX {pktSwchSnaPULlc2FrNumberS , pktSwchSnaPULlc2FrSideS} ::= { pktSwchSnaPULlc2FrTableS 1 } PktSwchSnaPULlc2FrEntryS ::= SEQUENCE { pktSwchSnaPULlc2FrNumberS Integer32, pktSwchSnaPULlc2FrSideS INTEGER, pktSwchSnaPULlc2FrEncapsTypeS INTEGER, pktSwchSnaPULlc2FrDestMACS OCTET STRING, pktSwchSnaPULlc2FrSrcSAPS OCTET STRING, pktSwchSnaPULlc2FrDestSAPS OCTET STRING, pktSwchSnaPULlc2FrXIDIdBlkS OCTET STRING, pktSwchSnaPULlc2FrXIDIdNumS OCTET STRING, pktSwchSnaPULlc2FrMaxPiuSizeS Integer32, pktSwchSnaPULlc2FrTxWindowS Integer32, pktSwchSnaPULlc2FrLinkS Integer32, pktSwchSnaPULlc2FrDLCIS Integer32, pktSwchSnaPULlc2FrXIDInitiationS INTEGER, pktSwchSnaPULlc2FrN2CountS Integer32, pktSwchSnaPULlc2FrT1TimerS Integer32, pktSwchSnaPULlc2FrTiTimerS Integer32, pktSwchSnaPULlc2FrEntryStatusS INTEGER } pktSwchSnaPULlc2FrNumberS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Unique Identifier for this PU. The value in this field is used as a common Key in both this table and the Main PU table. " ::= {pktSwchSnaPULlc2FrEntryS 1 } pktSwchSnaPULlc2FrSideS OBJECT-TYPE SYNTAX INTEGER { sideA(1), sideB(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates for each side (SIDE-A and SIDE-B) if the Protocol Interface for that side has been defined or not. " ::= {pktSwchSnaPULlc2FrEntryS 2} pktSwchSnaPULlc2FrEncapsTypeS OBJECT-TYPE SYNTAX INTEGER {ban(1),bnn(2),tren(3)} MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates if the LLC2/RFC1490 Protocol Interface uses the BNN, BAN or TREN method of Frame Encapsulation." ::= {pktSwchSnaPULlc2FrEntryS 3} pktSwchSnaPULlc2FrDestMACS OBJECT-TYPE SYNTAX OCTET STRING (SIZE(6)) MAX-ACCESS read-write STATUS current DESCRIPTION "The LLC2 Destination MAC Address." ::= {pktSwchSnaPULlc2FrEntryS 4} pktSwchSnaPULlc2FrSrcSAPS OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) MAX-ACCESS read-write STATUS current DESCRIPTION "The LLC2 Source SAP Address. 2 Hex digits" ::= {pktSwchSnaPULlc2FrEntryS 5} pktSwchSnaPULlc2FrDestSAPS OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) MAX-ACCESS read-write STATUS current DESCRIPTION "The LLC2 Destination SAP." ::= {pktSwchSnaPULlc2FrEntryS 6} pktSwchSnaPULlc2FrXIDIdBlkS OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..2)) MAX-ACCESS read-write STATUS current DESCRIPTION "Part of the IBM device ID (the full ID is defined by the IDBLK and the IDNUM). The IDBLK is required for PU with Local XID handling or PU with End-to-End XID handling, NO Support for NON-Activation XID. Up to 3 Hexadecimal digits, format: 0X XX." ::= {pktSwchSnaPULlc2FrEntryS 7} pktSwchSnaPULlc2FrXIDIdNumS OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..3)) MAX-ACCESS read-write STATUS current DESCRIPTION "Second part of the IBM device ID (the full ID is defined by the IDBLK and the IDNUM). The IDNUM is required for PU with Local XID handling or PU with End-to-End XID handling, NO Support for NON-Activation XID. Up to 5 Hexadecimal digits, format: 0X XX XX." ::= {pktSwchSnaPULlc2FrEntryS 8} pktSwchSnaPULlc2FrMaxPiuSizeS OBJECT-TYPE SYNTAX Integer32 (137..7642) MAX-ACCESS read-write STATUS current DESCRIPTION "Maximum Path Information Size" ::= { pktSwchSnaPULlc2FrEntryS 9} pktSwchSnaPULlc2FrTxWindowS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The LLC2 Link Window Size." ::= {pktSwchSnaPULlc2FrEntryS 10} pktSwchSnaPULlc2FrLinkS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The SPS Frame Relay Link Number which this LLC2 Protocol Interface is associated with." ::= {pktSwchSnaPULlc2FrEntryS 11} pktSwchSnaPULlc2FrDLCIS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The SPS Frame Relay DLCI Number which this LLC2 Protocol Interface is associated with." ::= {pktSwchSnaPULlc2FrEntryS 12} pktSwchSnaPULlc2FrXIDInitiationS OBJECT-TYPE SYNTAX INTEGER{ notInitiate(1), initiate(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter is not applicable for PU with Local XID handling. Legal values: 1 - Do not initiate an XID message. 2 - Initiate an XID message to LLC2." ::= { pktSwchSnaPULlc2FrEntryS 13} pktSwchSnaPULlc2FrN2CountS OBJECT-TYPE SYNTAX Integer32 (1..99999) MAX-ACCESS read-write STATUS current DESCRIPTION "N2 Count" ::= { pktSwchSnaPULlc2FrEntryS 14} pktSwchSnaPULlc2FrT1TimerS OBJECT-TYPE SYNTAX Integer32 (1..99999) MAX-ACCESS read-write STATUS current DESCRIPTION "T1 Timer in 1/10 of a second." ::= { pktSwchSnaPULlc2FrEntryS 15} pktSwchSnaPULlc2FrTiTimerS OBJECT-TYPE SYNTAX Integer32 (1..99999) MAX-ACCESS read-write STATUS current DESCRIPTION "TI Timer in seconds" ::= { pktSwchSnaPULlc2FrEntryS 16} pktSwchSnaPULlc2FrEntryStatusS OBJECT-TYPE SYNTAX INTEGER { valid(1), underCreation(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The status of this PU Llc2 table entry. In order to save this entry, set status to valid. An underCreation value is set by the Agent when this entry is updated." ::= {pktSwchSnaPULlc2FrEntryS 17} pktSwchSnaPULlc2FrTableA OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchSnaPULlc2FrEntryA MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines links for PUs running on an LLC2 link " ::= { pktSwchSna 12 } pktSwchSnaPULlc2FrEntryA OBJECT-TYPE SYNTAX PktSwchSnaPULlc2FrEntryA MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines parameters for PU LLC2 Protocol Interface over Frame Relay Protocol using RFC 1490." INDEX {pktSwchSnaPULlc2FrNumberA , pktSwchSnaPULlc2FrSideA} ::= { pktSwchSnaPULlc2FrTableA 1 } PktSwchSnaPULlc2FrEntryA ::= SEQUENCE { pktSwchSnaPULlc2FrNumberA Integer32, pktSwchSnaPULlc2FrSideA INTEGER, pktSwchSnaPULlc2FrEncapsTypeA INTEGER, pktSwchSnaPULlc2FrDestMACA OCTET STRING, pktSwchSnaPULlc2FrSrcSAPA OCTET STRING, pktSwchSnaPULlc2FrDestSAPA OCTET STRING, pktSwchSnaPULlc2FrXIDIdBlkA OCTET STRING, pktSwchSnaPULlc2FrXIDIdNumA OCTET STRING, pktSwchSnaPULlc2FrMaxPiuSizeA Integer32, pktSwchSnaPULlc2FrTxWindowA Integer32, pktSwchSnaPULlc2FrLinkA Integer32, pktSwchSnaPULlc2FrDLCIA Integer32, pktSwchSnaPULlc2FrXIDInitiationA INTEGER, pktSwchSnaPULlc2FrN2CountA Integer32, pktSwchSnaPULlc2FrT1TimerA Integer32, pktSwchSnaPULlc2FrTiTimerA Integer32 } pktSwchSnaPULlc2FrNumberA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Unique Identifier for this PU. The value in this field is used as a common Key in both this table and the Main PU table. " ::= {pktSwchSnaPULlc2FrEntryA 1 } pktSwchSnaPULlc2FrSideA OBJECT-TYPE SYNTAX INTEGER { sideA(1), sideB(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates for each side (SIDE-A and SIDE-B) if the Protocol Interface for that side has been defined or not. " ::= {pktSwchSnaPULlc2FrEntryA 2} pktSwchSnaPULlc2FrEncapsTypeA OBJECT-TYPE SYNTAX INTEGER {ban(1),bnn(2),tren(3)} MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates if the LLC2/RFC1490 Protocol Interface uses the BNN, BAN or TREN method of Frame Encapsulation." ::= {pktSwchSnaPULlc2FrEntryA 3} pktSwchSnaPULlc2FrDestMACA OBJECT-TYPE SYNTAX OCTET STRING (SIZE(6)) MAX-ACCESS read-only STATUS current DESCRIPTION "The LLC2 Destination MAC Address." ::= {pktSwchSnaPULlc2FrEntryA 4} pktSwchSnaPULlc2FrSrcSAPA OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) MAX-ACCESS read-only STATUS current DESCRIPTION "The LLC2 Source SAP Address." ::= {pktSwchSnaPULlc2FrEntryA 5} pktSwchSnaPULlc2FrDestSAPA OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) MAX-ACCESS read-only STATUS current DESCRIPTION "The LLC2 Destination SAP." ::= {pktSwchSnaPULlc2FrEntryA 6} pktSwchSnaPULlc2FrXIDIdBlkA OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..2)) MAX-ACCESS read-only STATUS current DESCRIPTION "Part of the IBM device ID (the full ID is defined by the IDBLK and the IDNUM). The IDBLK is required for PU with Local XID handling or PU with End-to-End XID handling, NO Support for NON-Activation XID. Up to 3 Hexadecimal digits, format: 0X XX." ::= {pktSwchSnaPULlc2FrEntryA 7} pktSwchSnaPULlc2FrXIDIdNumA OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..3)) MAX-ACCESS read-only STATUS current DESCRIPTION "Second part of the IBM device ID (the full ID is defined by the IDBLK and the IDNUM). The IDNUM is required for PU with Local XID handling or PU with End-to-End XID handling, NO Support for NON-Activation XID. Up to 5 Hexadecimal digits, format: 0X XX XX." ::= {pktSwchSnaPULlc2FrEntryA 8} pktSwchSnaPULlc2FrMaxPiuSizeA OBJECT-TYPE SYNTAX Integer32 (137..7642) MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum Path Information Size" ::= {pktSwchSnaPULlc2FrEntryA 9} pktSwchSnaPULlc2FrTxWindowA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The LLC2 Link Window Size." ::= {pktSwchSnaPULlc2FrEntryA 10} pktSwchSnaPULlc2FrLinkA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The SPS Frame Relay Link Number which this LLC2 Protocol Interface is associated with." ::= {pktSwchSnaPULlc2FrEntryA 11} pktSwchSnaPULlc2FrDLCIA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The SPS Frame Relay DLCI Number which this LLC2 Protocol Interface is associated with." ::= {pktSwchSnaPULlc2FrEntryA 12} pktSwchSnaPULlc2FrXIDInitiationA OBJECT-TYPE SYNTAX INTEGER{ notInitiate(1), initiate(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter is not applicable for PU with Local XID handling. Legal values: 1 - Do not initiate an XID message. 2 - Initiate an XID message to LLC2." ::= { pktSwchSnaPULlc2FrEntryA 13} pktSwchSnaPULlc2FrN2CountA OBJECT-TYPE SYNTAX Integer32 (1..99999) MAX-ACCESS read-only STATUS current DESCRIPTION "N2 Count" ::= { pktSwchSnaPULlc2FrEntryA 14} pktSwchSnaPULlc2FrT1TimerA OBJECT-TYPE SYNTAX Integer32 (1..99999) MAX-ACCESS read-only STATUS current DESCRIPTION "T1 Timer in 1/10 of a second." ::= { pktSwchSnaPULlc2FrEntryA 15} pktSwchSnaPULlc2FrTiTimerA OBJECT-TYPE SYNTAX Integer32 (1..99999) MAX-ACCESS read-only STATUS current DESCRIPTION "TI Timer in seconds" ::= { pktSwchSnaPULlc2FrEntryA 16} pktSwchSnaPULlc2FrStatTable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchSnaPULlc2FrStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Shows link statistics for PUs running on an LLC2 link " ::= { pktSwchSna 13 } pktSwchSnaPULlc2FrStatEntry OBJECT-TYPE SYNTAX PktSwchSnaPULlc2FrStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Shows statistics for PU LLC2 Protocol Interface over Frame Relay Protocol using RFC 1490." INDEX {pktSwchSnaPULlc2FrStatNumber , pktSwchSnaPULlc2FrStatSide} ::= { pktSwchSnaPULlc2FrStatTable 1 } PktSwchSnaPULlc2FrStatEntry ::= SEQUENCE { pktSwchSnaPULlc2FrStatNumber Integer32, pktSwchSnaPULlc2FrStatSide INTEGER, pktSwchSnaPULlc2FrStatOctetsIn Counter32, pktSwchSnaPULlc2FrStatOctetsOut Counter32, pktSwchSnaPULlc2FrStatIFramesIn Counter32, pktSwchSnaPULlc2FrStatIFramesOut Counter32, pktSwchSnaPULlc2FrStatRRFramesIn Counter32, pktSwchSnaPULlc2FrStatRRFramesOut Counter32, pktSwchSnaPULlc2FrStatRNRFramesIn Counter32, pktSwchSnaPULlc2FrStatRNRFramesOut Counter32, pktSwchSnaPULlc2FrStatXIDsIn Counter32, pktSwchSnaPULlc2FrStatXIDsOut Counter32, pktSwchSnaPULlc2FrStatTESTsIn Counter32, pktSwchSnaPULlc2FrStatTESTsOut Counter32, pktSwchSnaPULlc2FrStatREJsIn Counter32, pktSwchSnaPULlc2FrStatREJsOut Counter32, pktSwchSnaPULlc2FrStatFRMRsIn Counter32, pktSwchSnaPULlc2FrStatFRMRsOut Counter32, pktSwchSnaPULlc2FrStatDISCsIn Counter32, pktSwchSnaPULlc2FrStatDISCsOut Counter32, pktSwchSnaPULlc2FrStatUAsIn Counter32, pktSwchSnaPULlc2FrStatUAsOut Counter32, pktSwchSnaPULlc2FrStatDMsIn Counter32, pktSwchSnaPULlc2FrStatDMsOut Counter32, pktSwchSnaPULlc2FrStatSABMEsIn Counter32, pktSwchSnaPULlc2FrStatSABMEsOut Counter32, pktSwchSnaPULlc2FrStatRetransmitsIn Counter32, pktSwchSnaPULlc2FrStatRetransmitsOut Counter32, pktSwchSnaPULlc2FrStatUpperState INTEGER, pktSwchSnaPULlc2FrStatLowerState INTEGER, pktSwchSnaPULlc2FrStatNRMStatus INTEGER, pktSwchSnaPULlc2FrStatFlowCtlStatus INTEGER } pktSwchSnaPULlc2FrStatNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Unique Identifier for this PU. The value in this field is used as a common Key in both this table and the Main PU table. " ::= {pktSwchSnaPULlc2FrStatEntry 1 } pktSwchSnaPULlc2FrStatSide OBJECT-TYPE SYNTAX INTEGER { sideA(1), sideB(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates for each side (SIDE-A and SIDE-B) if the Protocol Interface for that side has been defined or not. " ::= {pktSwchSnaPULlc2FrStatEntry 2} pktSwchSnaPULlc2FrStatOctetsIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPULlc2FrStatEntry 3} pktSwchSnaPULlc2FrStatOctetsOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPULlc2FrStatEntry 4} pktSwchSnaPULlc2FrStatIFramesIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPULlc2FrStatEntry 5} pktSwchSnaPULlc2FrStatIFramesOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPULlc2FrStatEntry 6} pktSwchSnaPULlc2FrStatRRFramesIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPULlc2FrStatEntry 7} pktSwchSnaPULlc2FrStatRRFramesOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPULlc2FrStatEntry 8} pktSwchSnaPULlc2FrStatRNRFramesIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPULlc2FrStatEntry 9} pktSwchSnaPULlc2FrStatRNRFramesOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPULlc2FrStatEntry 10} pktSwchSnaPULlc2FrStatXIDsIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPULlc2FrStatEntry 11} pktSwchSnaPULlc2FrStatXIDsOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPULlc2FrStatEntry 12} pktSwchSnaPULlc2FrStatTESTsIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPULlc2FrStatEntry 13} pktSwchSnaPULlc2FrStatTESTsOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPULlc2FrStatEntry 14} pktSwchSnaPULlc2FrStatREJsIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPULlc2FrStatEntry 15} pktSwchSnaPULlc2FrStatREJsOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPULlc2FrStatEntry 16} pktSwchSnaPULlc2FrStatFRMRsIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPULlc2FrStatEntry 17} pktSwchSnaPULlc2FrStatFRMRsOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPULlc2FrStatEntry 18} pktSwchSnaPULlc2FrStatDISCsIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPULlc2FrStatEntry 19} pktSwchSnaPULlc2FrStatDISCsOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPULlc2FrStatEntry 20} pktSwchSnaPULlc2FrStatUAsIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPULlc2FrStatEntry 21} pktSwchSnaPULlc2FrStatUAsOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPULlc2FrStatEntry 22} pktSwchSnaPULlc2FrStatDMsIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPULlc2FrStatEntry 23} pktSwchSnaPULlc2FrStatDMsOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPULlc2FrStatEntry 24} pktSwchSnaPULlc2FrStatSABMEsIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPULlc2FrStatEntry 25} pktSwchSnaPULlc2FrStatSABMEsOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPULlc2FrStatEntry 26} pktSwchSnaPULlc2FrStatRetransmitsIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPULlc2FrStatEntry 27} pktSwchSnaPULlc2FrStatRetransmitsOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { pktSwchSnaPULlc2FrStatEntry 28} pktSwchSnaPULlc2FrStatUpperState OBJECT-TYPE SYNTAX INTEGER { unbound(1), bindPending(2), unbindPend(3), idle(4), unattached(5), attachPend(6), detachPend(7), udqosPending(8), outconPend(9), inconPending(10), connResPend(11), dataxfer(12), userResetPend(13), provRstPend(14), rstResPend(15), discon8Pend(16), discon9Pend(17), discon11Pend(18), discon12Pend(19), discon13Pend(20), subsBindPend(21), noChange(22) } MAX-ACCESS read-only STATUS current DESCRIPTION "The internal DLPI state of the connection." ::= { pktSwchSnaPULlc2FrStatEntry 29} pktSwchSnaPULlc2FrStatLowerState OBJECT-TYPE SYNTAX INTEGER { linkClosed(1), disconnected(2), linkOpening(3), disconnecting(4), frmrSent(5), linkOpened(6), localBusy(7), rejection(8), checkpointing(9), cpLocalBusy(10), cpRejection(11), resetting(12), remoteBusy(13), lBusyRBusy(14), rejLBusy(15), rejRBusy(16), cpRejLBusy(17), cpClearing(18), cpRejClr(19), rejLbusyRbusy(20), frmrReceived(21), programError(22), noChange(23) } MAX-ACCESS read-only STATUS current DESCRIPTION "The internal Llc2Fr state of the connection." ::= { pktSwchSnaPULlc2FrStatEntry 30} pktSwchSnaPULlc2FrStatNRMStatus OBJECT-TYPE SYNTAX INTEGER {sync(1),notSync(2)} MAX-ACCESS read-only STATUS current DESCRIPTION "This variable indicates if the link is in Normal Response Mode or not." ::= { pktSwchSnaPULlc2FrStatEntry 31} pktSwchSnaPULlc2FrStatFlowCtlStatus OBJECT-TYPE SYNTAX INTEGER {noRNR(1),txFlow(2), rxFlow(3), rxAndTx(4)} MAX-ACCESS read-only STATUS current DESCRIPTION "This variable indicates the flow control status of the PU interface." ::= { pktSwchSnaPULlc2FrStatEntry 32} pktSwchSnaGlobal OBJECT IDENTIFIER ::= { pktSwchSna 14 } pktSwchSnaGlobalSrcMacAddrS OBJECT-TYPE SYNTAX OCTET STRING (SIZE(6)) MAX-ACCESS read-write STATUS current DESCRIPTION "LLC2 source MAC address used for all LLC2\RFC1490 protocol interfaces, Scratch variable. Format: XX XX XX XX XX XX" ::= {pktSwchSnaGlobal 1} pktSwchSnaGlobalSrcMacAddrA OBJECT-TYPE SYNTAX OCTET STRING (SIZE(6)) MAX-ACCESS read-only STATUS current DESCRIPTION "LLC2 source MAC address used for all LLC2\RFC1490 protocol interfaces, Active variable. Format: XX XX XX XX XX XX" ::= {pktSwchSnaGlobal 2} pktSwchSnaGlobalDefFrLlc2LinkS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The FR Link to where a mac frame will be routed when the destination MAC address of the frame does not match the SPS source mac address." ::= {pktSwchSnaGlobal 3} pktSwchSnaGlobalDefFrLlc2LinkA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The FR Link to where a mac frame will be routed when the destination MAC address of the frame does not match the SPS source mac address." ::= {pktSwchSnaGlobal 4} pktSwchSnaGlobalDefFrLlc2DlciS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The FR DLCI to where a mac frame will be routed when the destination MAC address of the frame does not match the SPS source mac address. DLCI range is 16..991." ::= {pktSwchSnaGlobal 5} pktSwchSnaGlobalDefFrLlc2DlciA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The FR DLCI to where a mac frame will be routed when the destination MAC address of the frame does not match the SPS source mac address. DLCI range is 16..991." ::= {pktSwchSnaGlobal 6} pktSwchSnaGlobalMaxPus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of PUs that can be defined on this device. " ::= {pktSwchSnaGlobal 7} pktSwchSnaGlobalStatus OBJECT-TYPE SYNTAX INTEGER { valid(1), underCreation(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The status of this SNA Global entry. Used for saving the mac address, llc2 port, and dlci. " ::= {pktSwchSnaGlobal 8} pktSwchEthernet OBJECT IDENTIFIER ::= { radPS 12} pktSwchEthernetLinkTable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchEthernetLinkEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Ethernet link table defines the parameters in the PS Ethernet links." ::= { pktSwchEthernet 1 } pktSwchEthernetLinkEntry OBJECT-TYPE SYNTAX PktSwchEthernetLinkEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Ethernet Link Entry defines the contents of each link in the Ethernet Link Table." INDEX {ifIndex } ::= { pktSwchEthernetLinkTable 1 } PktSwchEthernetLinkEntry ::= SEQUENCE { pktSwchEthernetLinkOperationMode INTEGER, pktSwchEthernetLinkUserDefMacAddr OCTET STRING, pktSwchEthernetLinkPointToPointDest DisplayString, pktSwchEthernetLinkTotalFramesIn Counter32, pktSwchEthernetLinkTotalFramesOut Counter32, pktSwchEthernetLinkIpFramesIn Counter32, pktSwchEthernetLinkIpFramesOut Counter32, pktSwchEthernetLinkLlc2FramesIn Counter32, pktSwchEthernetLinkLlc2FramesOut Counter32, pktSwchEthernetLinkBridgFramesIn Counter32, pktSwchEthernetLinkBridgFramesOut Counter32, pktSwchEthernetLinkDiscardedByFilter Counter32 } pktSwchEthernetLinkOperationMode OBJECT-TYPE SYNTAX INTEGER{ bridging (3), ip (4), ip-and-bridging (7), llc (8), llc-and-bridging (11), ip-and-llc (12), all (15), none (255) -- disabled } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter shows the frame handling mode on this link. When IP mode is defined, the IP frames received on this link are handled and routed by the IP module in the PS. If IP mode is disabled, the IP frames will not be handled by the IP module and will be handled as bridged data. When Bridging mode is enabled, the PS will perform bridging from this link according to the bridging configuration. If disabled, bridge data will be ignored. When LLC is enabled, frames received on this link are handled by the LLC module in the PS. If disabled, the LLC frames will be treated as bridged data. Any combination of bridging, ip and LLC is allowed. If both IP and LLC are enabled, LLC frames will be handled by the LLC module, IP frames will be handled by the IP module, and all the other frames will treated as bridged data. If the bridge mode is disabled, the other frames will be discarded." ::= { pktSwchEthernetLinkEntry 1 } pktSwchEthernetLinkUserDefMacAddr OBJECT-TYPE SYNTAX OCTET STRING (SIZE(6)) MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter allows the user to define a different MAC address for this link other than the device MAC address. Possible values: 6 sets of 2 Hexadecimal digits with spaces between them (XX XX XX XX XX XX) " ::= { pktSwchEthernetLinkEntry 2 } pktSwchEthernetLinkPointToPointDest OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Destination of the frames which are received on this link. Possible values: X.25 PVC: Port:LCN X.25 SVC: X.25 Addr or 'cid' followed by a predefined Call ID number. Frame Relay: Port:DLCI No Destination: None If no destination, frames will be forwarded according to the filter table in 1st priority. If no filter match, the frames will be forwarded according to dynamic learning. Default value: None" ::={ pktSwchEthernetLinkEntry 3 } pktSwchEthernetLinkTotalFramesIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of frames which were received on this link." ::={ pktSwchEthernetLinkEntry 4 } pktSwchEthernetLinkTotalFramesOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of frames which were transmitted from this link." ::={ pktSwchEthernetLinkEntry 5 } pktSwchEthernetLinkIpFramesIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of IP frames which were received on this link." ::={ pktSwchEthernetLinkEntry 6 } pktSwchEthernetLinkIpFramesOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of IP frames which were transmitted from this link." ::={ pktSwchEthernetLinkEntry 7 } pktSwchEthernetLinkLlc2FramesIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of LLC2 frames which were received on this link." ::={ pktSwchEthernetLinkEntry 8 } pktSwchEthernetLinkLlc2FramesOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of LLC2 frames which were transmitted from this link." ::={ pktSwchEthernetLinkEntry 9 } pktSwchEthernetLinkBridgFramesIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of Bridged frames which were received on this link." ::={ pktSwchEthernetLinkEntry 10 } pktSwchEthernetLinkBridgFramesOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of Bridged frames which were transmitted from this link." ::={ pktSwchEthernetLinkEntry 11 } pktSwchEthernetLinkDiscardedByFilter OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of Bridged frames which were received on this link." ::={ pktSwchEthernetLinkEntry 12 } pktSwchEthernetFilterTable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchEthernetFilterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Ethernet filter table defines the frame filtering and routing through the PS Ethernet links." ::= { pktSwchEthernet 2 } pktSwchEthernetFilterEntry OBJECT-TYPE SYNTAX PktSwchEthernetFilterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Ethernet Filter Entry defines the filtering on each Ethernet link. The filter entry is operational only if Bridging Handling is enabled and there is no point to point destination configured for this link. If there is a point to point destination configured, the frames will be directed to this destination." INDEX {ifIndex, pktSwchEthernetFilterId} ::= { pktSwchEthernetFilterTable 1 } PktSwchEthernetFilterEntry ::= SEQUENCE { pktSwchEthernetFilterId Integer32, pktSwchEthernetFilterMacAddr OCTET STRING, pktSwchEthernetFilterProtType INTEGER, pktSwchEthernetFilterDest DisplayString, pktSwchEthernetFilterStatus INTEGER } pktSwchEthernetFilterId OBJECT-TYPE SYNTAX Integer32 (1..10) MAX-ACCESS read-only STATUS current DESCRIPTION "Identification Number of an entry in the filter table. The ID together with the ifindex define an entry." ::= { pktSwchEthernetFilterEntry 1 } pktSwchEthernetFilterMacAddr OBJECT-TYPE SYNTAX OCTET STRING (SIZE(6)) MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter defines the MAC address in the current entry of the filter table. The MAC address in the filter table is compared with the MAC address in the received frame. If the MAC address and protocol type of the frame are equal to the values in the filter table, the frame will be directed to the destination address specified in the filter table. Possible values: MAC Address : 6 sets of 2 Hexadecimal digits with spaces between them (XX XX XX XX XX XX) Broadcasting: FF FF FF FF FF FF Don't Care : 00 00 00 00 00 00 For Broadcasting: If a broadcasting entry contains a destination, the frame will not be broadcasted. It will be directed to the destination in this entry. For Don't care: The MAC address in the frame and in the filter table are not compared. The frames will be directed to the destination specified in the filter table if there is a match between the protocol types in the frame and in the filter table. Default value: 00 00 00 00 00 00 " ::= { pktSwchEthernetFilterEntry 2 } pktSwchEthernetFilterProtType OBJECT-TYPE SYNTAX INTEGER{ llc (256), ip (2048), arp (2054), appleTalk (32923), dontCare (65535) } MAX-ACCESS read-write STATUS current DESCRIPTION "The protocol type which is compared with the protocol type in the received frame. Each protocol in the IP frame is assigned 16 bits (see RFC1700.txt on the assignment of protocol parameters for the Internet protocol suite.). If 65535 is entered for the protocol, it means Don't Care. If there is a match between this protocol and the protocol in the received frame and a match in the MAC addresses, the frame will be directed to the destination specified in this table. Default value: dontCare (65535)." ::= { pktSwchEthernetFilterEntry 3} pktSwchEthernetFilterDest OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Destination of the frames which match this current entry. The match is in the MAC address and protocol. Possible values: X.25 PVC: Port:LCN X.25 SVC: X.25 Addr or 'cid' followed by a predefined Call ID number Frame Relay: Port:DLCI No Destination: None If No Destination, the frames will be discarded. Default value: None ." ::={ pktSwchEthernetFilterEntry 4} pktSwchEthernetFilterStatus OBJECT-TYPE SYNTAX INTEGER { valid(1), createRequest(2), underCreation(3), invalid(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The status of this filter table entry. valid - This entry was saved. createRequest - Request to create a new entry. underCreation - For a new/updated entry. invalid - Entry is deleted." ::= {pktSwchEthernetFilterEntry 5} pktSwchEthernetBridging OBJECT IDENTIFIER ::= { pktSwchEthernet 3 } pktSwchEthernetBridgingWanToWan OBJECT-TYPE SYNTAX INTEGER{ disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable Ethernet Bridging, WAN to WAN." ::= {pktSwchEthernetBridging 1} pktSwchEthernetBridgingTimer OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "Timer used for WAN to WAN communication in order to prevent broadcast frames looping forever between devices. When the timer expires, the frames are discarded. Possible values: 0 - No timer is used. 1..255 - Timer value in units of 100 mili sec." ::= {pktSwchEthernetBridging 2} pktSwchEthernetBridgingStatus OBJECT-TYPE SYNTAX INTEGER { valid(1), underCreation(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The status of the Ethernet Bridging Parameters. valid - This table was saved. underCreation - The table was updated and not yet saved." ::= {pktSwchEthernetBridging 3} pktSwchEthernetBroadcastDestTable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchEthernetBroadcastDestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Ethernet Broadcast Destination table defines all the Bridging destinations of the PS. Each Broadcasted frame will be broadcasted to all these destinations." ::= { pktSwchEthernet 4 } pktSwchEthernetBroadcastDestEntry OBJECT-TYPE SYNTAX PktSwchEthernetBroadcastDestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Ethernet Broadcast Entry defines destinations for Ethernet bridge data." INDEX {pktSwchEthernetBroadcastDestProtocol, pktSwchEthernetBroadcastDestId} ::= { pktSwchEthernetBroadcastDestTable 1 } PktSwchEthernetBroadcastDestEntry ::= SEQUENCE { pktSwchEthernetBroadcastDestProtocol INTEGER, pktSwchEthernetBroadcastDestId Integer32, pktSwchEthernetBroadcastDestDestination DisplayString, pktSwchEthernetBroadcastDestStatus INTEGER } pktSwchEthernetBroadcastDestProtocol OBJECT-TYPE SYNTAX INTEGER{ x25 (2), frameRelay (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The protocol of the Broadcasted frames." ::= { pktSwchEthernetBroadcastDestEntry 1 } pktSwchEthernetBroadcastDestId OBJECT-TYPE SYNTAX Integer32 (1..10) MAX-ACCESS read-only STATUS current DESCRIPTION "Identification Number of an entry in the Ethernet Broadcast Destination table." ::= { pktSwchEthernetBroadcastDestEntry 2 } pktSwchEthernetBroadcastDestDestination OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Destination for the Ethernet frames. Possible values for X25: X.25 PVC: Port:LCN X.25 SVC: X.25 Addr or 'cid' followed by a predefined Call ID number Possible values for fr: Frame Relay: Port:DLCI No Destination: None" ::={ pktSwchEthernetBroadcastDestEntry 3} pktSwchEthernetBroadcastDestStatus OBJECT-TYPE SYNTAX INTEGER { valid(1), createRequest(2), underCreation(3), invalid(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The status of this Ethernet Destination table entry. valid - This entry was saved. createRequest - Request to create a new entry. underCreation - For a new/updated entry. invalid - Entry is deleted." ::= {pktSwchEthernetBroadcastDestEntry 4} pktSwchIp OBJECT IDENTIFIER ::= { radPS 13} pktSwchIpGlobal OBJECT IDENTIFIER ::= { pktSwchIp 1 } pktSwchIpGlobalMaxHopCount OBJECT-TYPE SYNTAX Integer32 (5..65000) MAX-ACCESS read-write STATUS current DESCRIPTION "Maximum no. of hops the device will support. The default value is 15. Legal values: 5 to 65000." ::= {pktSwchIpGlobal 1} pktSwchIpIntervalBetweenUpdates OBJECT-TYPE SYNTAX Integer32 (30..2550) MAX-ACCESS read-write STATUS current DESCRIPTION "The time in seconds from one update of the device's dynamic routing table to the next update. The time is in steps of 10 seconds. Default value: 30 Legal values: 30,40,50 ... 2550" ::= {pktSwchIpGlobal 2} pktSwchIpGlobalStatus OBJECT-TYPE SYNTAX INTEGER { valid(1), underCreation(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The status of this IP Global entry. Used for saving the IP Global parameters. " ::= {pktSwchIpGlobal 3} pktSwchIpInterfaceTable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchIpInterfaceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Ip interface table defines the Ip interfaces and their parameters in the PS device." ::= { pktSwchIp 2 } pktSwchIpInterfaceEntry OBJECT-TYPE SYNTAX PktSwchIpInterfaceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The IP interface Entry defines the IP configuration parameters for each IP interface." INDEX {pktSwchIpInterfaceId} ::= { pktSwchIpInterfaceTable 1 } PktSwchIpInterfaceEntry ::= SEQUENCE { pktSwchIpInterfaceId Integer32, pktSwchIpInterfaceAddress IpAddress, pktSwchIpInterfaceAddressMask IpAddress, pktSwchIpInterfaceSendDefRoutMsgOnly INTEGER, pktSwchIpInterfaceDest DisplayString, pktSwchIpInterfaceInactivity Integer32, pktSwchIpInterfaceLinkCost Integer32, pktSwchIpInterfaceOptions INTEGER, pktSwchIpInterfaceStatus INTEGER, pktSwchIpInterfaceRxFrames Counter32, pktSwchIpInterfaceRxExpiredTtl Counter32, pktSwchIpInterfaceRxUnknownDest Counter32, pktSwchIpInterfaceTxFrames Counter32, pktSwchIpInterfaceTxQueueBufs Counter32, pktSwchIpInterfaceTxDiscarded Counter32, pktSwchIpInterfaceRipRxFrames Counter32, pktSwchIpInterfaceRipTxFrames Counter32, pktSwchIpInterfaceRipWaitingMsgs Counter32 } pktSwchIpInterfaceId OBJECT-TYPE SYNTAX Integer32 (1..200) MAX-ACCESS read-only STATUS current DESCRIPTION "Identification Number of an entry in the IP interface table." ::= { pktSwchIpInterfaceEntry 1 } pktSwchIpInterfaceAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The IP address of the interface. Legal input: any legal IP address. Default value: 0.0.0.0 " ::= { pktSwchIpInterfaceEntry 2 } pktSwchIpInterfaceAddressMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The IP mask of the interface. Legal input: any legal IP mask: A string of the format X.X.X.X where every X is a number in the range 0-255. Default value: 255.255.255.255 " ::= { pktSwchIpInterfaceEntry 3 } pktSwchIpInterfaceSendDefRoutMsgOnly OBJECT-TYPE SYNTAX INTEGER { disable (2), enable(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Some of the RIP messages are default router messages. These messages inform who the default router is. This MIB object allows the user to configure the device so that it will send default router messages only. If sendDefaultRoutMsgOnly is set to enable, the device will not send any RIP messages except for default router messages. Default value: disable ." ::= { pktSwchIpInterfaceEntry 4 } pktSwchIpInterfaceDest OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Destination of the packets received on this interface. Possible values: X.25 PVC: Port:LCN X.25 SVC: X.25 Addr or 'cid' followed by a predefined Call ID number. Frame Relay: Port:DLCI HDLC: 'H' followed by the HDLC Port Number SLIP: 'S' followed by the SLIP Channel Number Ethernet: 'E' followed by the Ethernet Port Number PPP: 'P' followed by the PPP Port Number. Bundles(for PPP)'B' followed by the PPP Bundle Number. No destination: None Default : None Examples: 1. For SLIP destination which is Link no. 1, the destination will be S100 (100 instead of 1 is for Async). 2. For SLIP destination of APS-8, channel no. 8: S8 3. For PPP destination of APS-8, Sync Link no. 1: P1 4. For PPP destination of APS-8, Async channel on link 1: P100 Note for PPP: PPP protocol is allowed to be applied on Sync Links (1-3) as well as Async channels (1-24). In the ascii terminal: If the user writes P1 for example the device has to check which P1 it is. Is it the async channel 1 or Link no. 1. The device does NOT ALLOW configuring PPP on both Sync Link no. 1 and async RJ45 channel 1. When P1 is entered by the user, the protocols on async channel 1 and sync link 1 are checked. As only one of them is PPP, it will apply to the only PPP chan/link." ::= { pktSwchIpInterfaceEntry 5 } pktSwchIpInterfaceInactivity OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "Inactivity time in minutes before disconnecting the X25 SVC call. Range: 0..255. Default: 2." ::= { pktSwchIpInterfaceEntry 6 } pktSwchIpInterfaceLinkCost OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This value will be added to the value written in the metric field of the received frame. Range: 1..pktSwchIpGlobalMaxHopCount Default: 1." ::= { pktSwchIpInterfaceEntry 7 } pktSwchIpInterfaceOptions OBJECT-TYPE SYNTAX INTEGER { netIpAddress (2), none (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "When netIpAddress is selected the interface IP address will not be the IP address of the interface. It will be the IP address of the NetWork which is connected to this interface. This option is for an interface which does not require a unique IP address. Default is none." ::= { pktSwchIpInterfaceEntry 8 } pktSwchIpInterfaceStatus OBJECT-TYPE SYNTAX INTEGER { valid(1), createRequest(2), underCreation(3), invalid(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The status of this filter table entry. valid - This entry was saved. createRequest - Request to create a new entry. underCreation - For a new/updated entry. invalid - Entry is deleted." ::= { pktSwchIpInterfaceEntry 9 } pktSwchIpInterfaceRxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "No. of frames which were received on this IP interface." ::= { pktSwchIpInterfaceEntry 10 } pktSwchIpInterfaceRxExpiredTtl OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "No. of frames which were received on this IP interface with an Expired Time to Live value." ::= { pktSwchIpInterfaceEntry 11 } pktSwchIpInterfaceRxUnknownDest OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "No. of frames which were received on this IP interface with an unknown IP destination. No default router is configured. These frames will be discarded." ::= { pktSwchIpInterfaceEntry 12 } pktSwchIpInterfaceTxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "No. of frames which were Transmitted from this IP interface." ::= { pktSwchIpInterfaceEntry 13 } pktSwchIpInterfaceTxQueueBufs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "No. of buffers which are waiting in the Trasnsmit Queue. " ::= { pktSwchIpInterfaceEntry 14 } pktSwchIpInterfaceTxDiscarded OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "No. of frames which were ready to be transmitted but were Discarded. The PS will discard frames if the transmit queue is too long." ::= { pktSwchIpInterfaceEntry 15 } pktSwchIpInterfaceRipRxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "No. of RIP frames which were received on this IP interface." ::= { pktSwchIpInterfaceEntry 16 } pktSwchIpInterfaceRipTxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "No. of RIP Frames which were transmitted from this IP interface." ::= { pktSwchIpInterfaceEntry 17 } pktSwchIpInterfaceRipWaitingMsgs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "No. of RIP messages which are waiting to be transmitted to the Network." ::= { pktSwchIpInterfaceEntry 18 } pktSwchIsdn OBJECT IDENTIFIER ::= { radPS 14} -- Packet Switching devices with Integrated Services Digital Network. pktSwchIsdnGlobal OBJECT IDENTIFIER ::= { pktSwchIsdn 1 } -- ISDN Global Parameters pktSwchIsdnGlobalCallRetries OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "Number of times the call request is repeated after failure. Possible values: 0 - Disable retry mechanism 1-255 - Number of retries default value: 0" ::= {pktSwchIsdnGlobal 1} pktSwchIsdnGlobalCallRetryDelay OBJECT-TYPE SYNTAX Integer32 (5..250) MAX-ACCESS read-write STATUS current DESCRIPTION "Time interval between retries (in seconds). Possible values: 5 - 250 Default value: 15" ::= {pktSwchIsdnGlobal 2} pktSwchIsdnGlobalCallinactivity OBJECT-TYPE SYNTAX Integer32 (0..65000) MAX-ACCESS read-write STATUS current DESCRIPTION "Time of inactivity in seconds, after which the call will be disconnected. An x.25 link is considered inactive when there are no open calls on the link. A frame relay link is considered inactive when there is no traffic on the link. Possible values: 0 - No disconnection on inactivity. 1 - 65000 - Time period (in seconds). Default value: 180" ::= {pktSwchIsdnGlobal 3} pktSwchIsdnGlobalStatus OBJECT-TYPE SYNTAX INTEGER { valid(1), underCreation(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The status of the Isdn Global parameters. Used for saving the Isdn global parameters." ::= {pktSwchIsdnGlobal 4} pktSwchIsdnRoutTable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchIsdnRoutEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Isdn Routing Table entries in the Packet Switch." ::= { pktSwchIsdn 2 } pktSwchIsdnRoutEntry OBJECT-TYPE SYNTAX PktSwchIsdnRoutEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Isdn Routing Entry defines the contents of each entry in the table. The outgoing addresses are in a different table - pktSwchIsdnRoutAddrTable. The row status in this table will be used for both tables." INDEX { pktSwchIsdnRoutId } ::= { pktSwchIsdnRoutTable 1 } PktSwchIsdnRoutEntry ::= SEQUENCE { pktSwchIsdnRoutId Integer32, pktSwchIsdnRoutDataBandWidth INTEGER, pktSwchIsdnRoutOptions INTEGER, pktSwchIsdnRoutStatus INTEGER } pktSwchIsdnRoutId OBJECT-TYPE SYNTAX Integer32 (1..200) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of this routing entry." ::= { pktSwchIsdnRoutEntry 1 } pktSwchIsdnRoutDataBandWidth OBJECT-TYPE SYNTAX INTEGER { bw56Kbps(2), bw64Kbps(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Isdn Bandwidth which will be used for the data routed via this entry. The ISDN interface will be configured with the speed which is selected. Possible values: 2 - 56 Kbps. 3 - 64 Kbps. Default value: 3 " ::= { pktSwchIsdnRoutEntry 2 } pktSwchIsdnRoutOptions OBJECT-TYPE SYNTAX INTEGER { noOptions(1), returnToMainLink(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Special Options for this routing entry. Possible values: 1 - No special options. 2 - Return to main link. This option is used when the current link is defined as a backup link and the main link becomes active. Default value: 1 " ::= { pktSwchIsdnRoutEntry 3 } pktSwchIsdnRoutStatus OBJECT-TYPE SYNTAX INTEGER { valid(1), createRequest(2), underCreation(3), invalid(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The status of this routing table entry + address table (pktSwchIsdnOutAddrTable). For creating a new entry select createRequest. A new route entry will be created together with an out address entry. There may be more than 1 addresses. For example, if there is 1 outgoing address and 2 alternatives, the new address entry will have 3 indices. For deleting an entry select invalid. The relevant address entry should be deleted too. For saving an entry select valid. Save should include the addresses of the current entry in the pktSwchIsdnOutAddrTable" ::= { pktSwchIsdnRoutEntry 4 } pktSwchIsdnOutAddrTable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchIsdnOutAddrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Outgoing ISDN addresses used by the ISDN routing table. The address table contains outgoing addresses and alternative addresses in case the connection to the first addresses does not succeed." ::= { pktSwchIsdn 3 } pktSwchIsdnOutAddrEntry OBJECT-TYPE SYNTAX PktSwchIsdnOutAddrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Isdn Outgoing Address Entry defines the contents of each entry in the outgoing address table. Each entry has 2 indices: 1. RoutId is the ID in the routing table. 2. AddrId is the ID containing the Outgoing address and sub address. " INDEX { pktSwchIsdnOutAddrRoutId, pktSwchIsdnOutAddrId } ::= { pktSwchIsdnOutAddrTable 1 } PktSwchIsdnOutAddrEntry ::= SEQUENCE { pktSwchIsdnOutAddrRoutId Integer32, pktSwchIsdnOutAddrId Integer32, pktSwchIsdnOutAddr DisplayString, pktSwchIsdnOutSubAddr DisplayString } pktSwchIsdnOutAddrRoutId OBJECT-TYPE SYNTAX Integer32 (1..200) MAX-ACCESS read-only STATUS current DESCRIPTION "ID in the ISDN routing table." ::= { pktSwchIsdnOutAddrEntry 1 } pktSwchIsdnOutAddrId OBJECT-TYPE SYNTAX Integer32 (1..3) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of the address + subaddress pair for each routing ID." ::= { pktSwchIsdnOutAddrEntry 2 } pktSwchIsdnOutAddr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..17)) MAX-ACCESS read-write STATUS current DESCRIPTION "Destination ISDN Outgoing (Remote) address. The data will be routed out to this address. Possible values: Up to 17 decimal digits. Default value: string of length 0." ::= { pktSwchIsdnOutAddrEntry 3 } pktSwchIsdnOutSubAddr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..6)) MAX-ACCESS read-write STATUS current DESCRIPTION "Destination ISDN Outgoing (Remote) sub address. The data will be routed out to the out addrress with this sub address. Possible values: Up to 6 decimal digits. Default value: string of length 0." ::= { pktSwchIsdnOutAddrEntry 4 } pktSwchIsdnAcceptTable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchIsdnAcceptEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of Isdn addresses which will be accepted by the agent. If there is a dial back (answer) address, the incoming call will be disconnected and dial back will initiate. Most of the accept list parameters are in RFC2128 in the dialCtlPeerCfgTable. The parameters which are not in the the standard RFC2128 and are required, are defined here in the private PS MIB." ::= { pktSwchIsdn 4 } pktSwchIsdnAcceptEntry OBJECT-TYPE SYNTAX PktSwchIsdnAcceptEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Isdn Accept Entry defines the contents of each entry in the table." INDEX { pktSwchIsdnAcceptId } ::= { pktSwchIsdnAcceptTable 1 } PktSwchIsdnAcceptEntry ::= SEQUENCE { pktSwchIsdnAcceptId Integer32, pktSwchIsdnAcceptSecondaryLink Integer32, pktSwchIsdnAcceptDialbkSubAddress DisplayString, pktSwchIsdnAcceptStatus INTEGER } pktSwchIsdnAcceptId OBJECT-TYPE SYNTAX Integer32 (1..200) MAX-ACCESS read-write STATUS current DESCRIPTION "Identifier of Accept table entry." ::= { pktSwchIsdnAcceptEntry 1 } pktSwchIsdnAcceptSecondaryLink OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-write STATUS current DESCRIPTION "A valid Isdn link number on which the call will be accepted when the Primary link (RFC2128.dialCtlPeerCfgLowerIf)is unavailable. Possible values: 255 - No Secondary link. or The complementary to the primary ISDN link number. Complementary links are: [1;2] and [7;8]. If Primary Link Number is set to first available <0>, the Secondary link must be set to No Secondary link <255>. Default value is complementary to the primary link no. defined in rfc2128.dialCtlPeerCfgLowerIf." ::= { pktSwchIsdnAcceptEntry 2 } pktSwchIsdnAcceptDialbkSubAddress OBJECT-TYPE SYNTAX DisplayString (SIZE (0..6)) MAX-ACCESS read-write STATUS current DESCRIPTION "Isdn sub address which will be used by the agent for dialing back. Possible values: Up to 6 decimal digits. Default value: string of length 0." ::= { pktSwchIsdnAcceptEntry 3 } pktSwchIsdnAcceptStatus OBJECT-TYPE SYNTAX INTEGER { valid(1), createRequest(2), underCreation(3), invalid(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The status of this accept table entry. For creating a new entry select createRequest, For deleting an entry select invalid. For saving an entry select valid." ::= { pktSwchIsdnAcceptEntry 4 } pktSwchIsdnLinkTable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchIsdnLinkEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of Isdn Link parameters. Most of the link parameters are in in RFC2127. Isdn Call statistics are RFC2128. The parameters which are not in the the standard RFCs , and are required, are defined here in the private PS MIB." ::= { pktSwchIsdn 5 } pktSwchIsdnLinkEntry OBJECT-TYPE SYNTAX PktSwchIsdnLinkEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Isdn Link Entry defines the contents of each entry in the table." INDEX {ifIndex } ::= { pktSwchIsdnLinkTable 1 } PktSwchIsdnLinkEntry ::= SEQUENCE { pktSwchIsdnLinkBchannel INTEGER, pktSwchIsdnCallsClrs Counter32, pktSwchIsdnTestCmd INTEGER, pktSwchIsdnTestAddr DisplayString, pktSwchIsdnTestSubAddr DisplayString } pktSwchIsdnLinkBchannel OBJECT-TYPE SYNTAX INTEGER { noBchannel(1), b1(2), b2(3), b1Andb2(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Defines which B channels are used for Leased Lines Only. Default value: noBchannel(1)." ::= { pktSwchIsdnLinkEntry 1 } pktSwchIsdnCallsClrs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of calls on this link which were cleared since the link was activated." ::= { pktSwchIsdnLinkEntry 2 } pktSwchIsdnTestCmd OBJECT-TYPE SYNTAX INTEGER { noOp (2), activate (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Activate/Stop an ISDN test on the current ISDN link. In order to Activate the test, set the TestCmd to 3 (activate). For stopping the test, set the TestCmd to 2 (noOp). Important: In order for the test to succeed, the user must set the pktSwchIsdnTestAddr and Subaddr to their required values before activating the test. " ::= { pktSwchIsdnLinkEntry 3 } pktSwchIsdnTestAddr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..17)) MAX-ACCESS read-write STATUS current DESCRIPTION "Destination ISDN Outgoing (Remote) address which will be called in order to test the ISDN. Possible values: Up to 17 decimal digits. Default value: string of length 0. Important: In order for the test to succeed, the user must also set the pktSwchIsdnTestSubAddr to the required values before activating the test. " ::= { pktSwchIsdnLinkEntry 4 } pktSwchIsdnTestSubAddr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..6)) MAX-ACCESS read-write STATUS current DESCRIPTION "Destination ISDN Outgoing (Remote) address which will be called in order to test the ISDN. Possible values: Up to 6 decimal digits. Default value: string of length 0. Important: In order for the test to succeed, the user must also set the pktSwchIsdnTestAddr to the required values before activating the test. " ::= { pktSwchIsdnLinkEntry 5 } pktSwchPpp OBJECT IDENTIFIER ::= { radPS 15} -- Point to Point Protocol in the Packet Switching devices. -- PPP Global Parameters: -- All the parameters are in: RFC1472, PPP Security Secrets Table. -- The Security Secrets table contains pairs of Identity and secrets -- (Port User Name and Port Password). -- The link no. which is used for the Secrets table is: 0. -- Link no. 0 in RFC1472 means that the ID/Secret pair applies to all links. -- -- The ROW status of rfc1472 could not be used because it has only 2 values: -- valid and invalid. There is no option for create request as is used -- in the Packet Switches. -- The only parameter which was added here is the ROW status for the table. pktSwchPppSecretsTable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchPppSecretsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of PPP Secret parameters. The parameters are defined in rfc1472 except for the ROW status which is defined here. In the standard, there is no create request option, so in order to be consistent with other ROW statuses in the Packet Switches it is defined here." ::= { pktSwchPpp 1 } pktSwchPppSecretsEntry OBJECT-TYPE SYNTAX PktSwchPppSecretsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "PPP Secrets Entry defines the contents of each entry in the table." INDEX {pktSwchPppSecretsPairId} ::= { pktSwchPppSecretsTable 1 } PktSwchPppSecretsEntry ::= SEQUENCE { pktSwchPppSecretsPairId Integer32, pktSwchPppSecretsStatus INTEGER } pktSwchPppSecretsPairId OBJECT-TYPE SYNTAX Integer32 (1..200) MAX-ACCESS read-only STATUS current DESCRIPTION "Index of the Secrets Pair." ::= { pktSwchPppSecretsEntry 1 } pktSwchPppSecretsStatus OBJECT-TYPE SYNTAX INTEGER { valid(1), createRequest(2), underCreation(3), invalid(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The status of the PPP Secrets table. For creating a new entry select createRequest, For deleting an entry select invalid. For saving an entry select valid." ::= { pktSwchPppSecretsEntry 2 } pktSwchPppChanTable OBJECT-TYPE SYNTAX SEQUENCE OF PktSwchPppChanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of PPP Channel parameters. The table can be used for Async as well as Sync parameters. In case a parameter is irrelevant for Async or Sync a value may be returned. Statistics Parameters are already defined in rfc1213: ifInUcastPkts, ifOutUcastPkts, ifInErrors, ifOutErrors" ::= { pktSwchPpp 2 } pktSwchPppChanEntry OBJECT-TYPE SYNTAX PktSwchPppChanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "PPP Channel Entry defines the contents of each entry in the table." INDEX {ifIndex } ::= { pktSwchPppChanTable 1 } PktSwchPppChanEntry ::= SEQUENCE { pktSwchPppChanSpeed INTEGER, pktSwchPppChanFlowCtlDuration Integer32, pktSwchPppChanStopBits INTEGER, pktSwchPppChanBitPerChar Integer32, pktSwchPppChanParity INTEGER, pktSwchPppChanNegotiationTrigger INTEGER, pktSwchPppChanMRU Integer32, pktSwchPppChanACCM OCTET STRING, pktSwchPppChanAuthentication INTEGER, pktSwchPppChanInternalClock INTEGER, pktSwchPppChanBundle Integer32, pktSwchpPppChanIsdnRoutId Integer32, pktSwchpPppChanLastEvent DisplayString } pktSwchPppChanSpeed OBJECT-TYPE SYNTAX INTEGER { s110bps (1), s300bps (2), s1200bps (3), s600bps (4), s75bps (5), s150bps (6), s2400bps (12), s4800bps (13), s9600bps (14), s19200bps (15), s38400bps (19), s57600bps (20), s115200bps(21), notApplicable(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "The port's speed in bits per second. For Async channels: Default value: 14 . For Sync Links: Use not_applicable(255) The Sync Links have an internal clock with different values." ::= { pktSwchPppChanEntry 1 } pktSwchPppChanFlowCtlDuration OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION " Hardware Flow Control Duration. 1..254 - Duration (in 50ms intervals). when timer expires, flow control stops. 0 - No Hardware flow control. 255 - Continuous Flow Control. Default value: 0. For Sync Links, return 0." ::= { pktSwchPppChanEntry 2 } pktSwchPppChanStopBits OBJECT-TYPE SYNTAX INTEGER { one (1), two (2), oneAndHalf(3), notApplicable(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This entry indicates the number of stop bits per character. The options are either (1) one stop bit, (2) two stop bits, or (3) 1.5 stop bits. For Sync Links: notApplicable(255)." ::= { pktSwchPppChanEntry 3 } pktSwchPppChanBitPerChar OBJECT-TYPE SYNTAX Integer32 (0..8) MAX-ACCESS read-write STATUS current DESCRIPTION "The number of data bits per character supported by the ppp link. Legal values for Async channels: 5..8 . For Sync Links: 0" ::= { pktSwchPppChanEntry 4 } pktSwchPppChanParity OBJECT-TYPE SYNTAX INTEGER { space(1), mark(2), even(3), odd(4), none(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This entry selects the type of parity to be checked or generated. The options are (1) space parity, (2) mark parity, (3) even parity, (4) odd parity, or (255) no parity. For Sync Links: none(255)." ::= { pktSwchPppChanEntry 5 } pktSwchPppChanNegotiationTrigger OBJECT-TYPE SYNTAX INTEGER { hw-signal (1), data-triggered (2), hw-signal-or-data(3), after-reset (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "The trigger which is used in order to start the Negotiation. The HW signals which are used are: DCD (Data Carrier Detect) - issued by DCE DSR (Data Set Ready) - issued by DCE DTR (Data Terminal Ready) - issued by DTE 1 - Start negotiation on signal assertion. The Peer will issue a DCD/DSR Signal if it is DCE or DTR if it is DTE. If the current channel/link is DCE, it will check the DTR. If the current channel/link is DTE, it will check the DCD/DSR. When the HW signal is issued, negotiation will begin. 2 - Data Triggered. The current channel/link will issue a HW signal. Negotiation will begin when data is received. 3 - Combination of option 1 and option 2. 255 - Starts negotiation after reset. Ignore HW signals. Default Value for Async Channel: 255. Default Value for Sync Link: 3" ::= { pktSwchPppChanEntry 6 } pktSwchPppChanMRU OBJECT-TYPE SYNTAX Integer32 (1500..4096) MAX-ACCESS read-write STATUS current DESCRIPTION "Maximum Receive Unit. Size of the packet which is negotiated with the connected device. Default value: 1500 ." ::= { pktSwchPppChanEntry 7 } pktSwchPppChanACCM OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) MAX-ACCESS read-write STATUS current DESCRIPTION "Async Control Character Map - The ACCM value serves as a mask for the first 32 characters in the ASCII table. Control characters may cause problems when they are transferred on the network. This can be handled by escaping them ( adding escape character to them ). For example , when using modems in the network which can not receive X-on and X-off characters. The ACCM is a mask which shows which control characters will be handled with an escape sequence. Each bit represents one character. Possible values: Octet string of 4 bytes: 00000000 . A bit with value 1 will cause the character to be in an escape sequence. 0 will leave the character as it is. Example : to use XON and XOFF as escape sequence : 000A0000 Default value: 00000000. For Sync Links return the default." ::= { pktSwchPppChanEntry 8 } pktSwchPppChanAuthentication OBJECT-TYPE SYNTAX INTEGER { no-authentication(1), pap-or-chap (2), chap-only (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Port Authentication Type. 1 - No Authentication: User side Only. 2 - Configuration of the Host side. PAP (Password Authentication Protocol) or CHAP (Challenge Handshake Authentication Protocol) will be accepted by the current host. 3 - Configuration of the host side as CHAP only. Only CHAP will be accepted by the current host. Default value: 1 ." ::= { pktSwchPppChanEntry 9 } pktSwchPppChanInternalClock OBJECT-TYPE SYNTAX INTEGER { r3000bps (1), r4800bps (2), r9600bps (3), r14400bps(4), r19200bps(5), r38400bps(6), r48Kbps (7), r56Kbps (8), r64Kbps (9), r128Kbps (10), r256Kbps (11), r384Kbps (12), r512Kbps (13), r768Kbps (14), r1024Kbps(15), r1445Kbps(16), r2048Kbps(17), external(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "The internal clock rate of the MLPPP Link. Default value: 9. For Async channels: return 255." ::= { pktSwchPppChanEntry 10 } pktSwchPppChanBundle OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "Bundle Number. It is possible to attach a few channels/links to a bundle. If the User enters a non existing bundle number, the PS will create a new bundle with this number. The bundle number may be: 1..255 If the bundle number is 0 it means: do not attach to bundle. Default value: 0 ." ::= { pktSwchPppChanEntry 11 } pktSwchpPppChanIsdnRoutId OBJECT-TYPE SYNTAX Integer32 (0..200) MAX-ACCESS read-write STATUS current DESCRIPTION "ISDN destination. ID (1..200) in the ISDN routing table containing the outgoing ISDN address for this channel/link. For no destination: 0 Default value: 0 " ::= { pktSwchPppChanEntry 12 } pktSwchpPppChanLastEvent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) MAX-ACCESS read-only STATUS current DESCRIPTION "Status showing the last PPP event which occured on the line described in an ascii string. Examples: 1. Received Configuration Request. 2. Sent Protocol Reject. 3. Error: Can Not Compress Frame. Default: 0 for no last event on this link or channel." ::= { pktSwchPppChanEntry 13 } -- TRAPS for use by the PS linkProtocolChanged NOTIFICATION-TYPE OBJECTS { pktSwchPhyInterfaceIfIndex, pktSwchPhyInterfaceProtocolA} STATUS current DESCRIPTION "Upon setting of a new protocol to a specific interface." ::= { radSysPSEvents 1 } enrollmentPS NOTIFICATION-TYPE STATUS current DESCRIPTION "Periodic trap to be sent to the list of managers." ::= { radSysPSEvents 2 } rtsChange NOTIFICATION-TYPE OBJECTS { pktSwchChannelNumberA } STATUS current DESCRIPTION " " ::= { radSysPSEvents 3 } ledStatusChange NOTIFICATION-TYPE OBJECTS { agnLed } STATUS current DESCRIPTION "The trap is sent when one of the Hazard LEDs has changed." ::= { radSysPSEvents 4 } -- -- file :v:\doc\rdv\mib\ver485\modem.txt -- -- MODMSYS MIB (MODEMS) --Title: RAD's Modems MIB --Version: 1.0 --Date: 24.12.95 --By: Yair Arian and Smadar Tauber --File: modem.txt -- --Last update: 15-Apr-2002 by Shlomo Shoham modmSys OBJECT IDENTIFIER ::= {radWan 4} modmSystem OBJECT IDENTIFIER ::= {modmSys 1} modmSa OBJECT IDENTIFIER ::= {modmSystem 1} modmHub OBJECT IDENTIFIER ::= {modmSystem 2} modmSaConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF ModmSaConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Configuration parameters of the Central and Remote Modems. The table will be RW for a Central agent and RO for a Remote agent." ::= { modmSa 1 } modmSaConfigEntry OBJECT-TYPE SYNTAX ModmSaConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {modmSaConfigMode} ::= { modmSaConfigTable 1} ModmSaConfigEntry ::= SEQUENCE { modmSaConfigMode INTEGER, modmSaConfigLoopback INTEGER, modmSaConfigAlrClearOnCmd INTEGER, modmSaConfigAlrClearAllCmd INTEGER, modmSaConfigTestClearCmd INTEGER, modmSaConfigClkMaster INTEGER, modmSaConfigResetStatistics INTEGER, modmSaConfigActiveTs Integer32, modmSaConfigReset INTEGER, modmSaConfigRemote INTEGER, modmSaConfigPsType INTEGER, modmSaConfigWorkMode INTEGER } modmSaConfigMode OBJECT-TYPE SYNTAX INTEGER { central(1), remote (2), remote2(3), remote3(4), remote4(5), remote5(6), remote6(7), remote7(8), remote8(9), remote9(10), remote10(11) } MAX-ACCESS read-only STATUS current DESCRIPTION "The mode indicates if the configuration parameters refer the Central or the Remote Modem. For AMC 102 the remote means regenerator. There can be some regenerators connecting one by the other." ::= { modmSaConfigEntry 1} modmSaConfigLoopback OBJECT-TYPE SYNTAX INTEGER { noLoopback(1), localPortLoop(2), localLineLoop(3), remPortLoop(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The possible loopbacks. It is not possible to have a remPortLoop(4) in both, Central and Remote units simultaneously." ::= { modmSaConfigEntry 2} modmSaConfigAlrClearOnCmd OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to on, clears all the events, both from the active alarms list and from the alarms buffer. Upon completion, the value will automatically change to off(2)." ::= { modmSaConfigEntry 3 } modmSaConfigAlrClearAllCmd OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to on, clears all the alarms of the alarm buffer and active alarms list. Upon completion, the value will automatically change to off(2)." ::= { modmSaConfigEntry 4 } modmSaConfigTestClearCmd OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to on, clears all the user-initiated tests and loopbacks. The variable modmSaConfigLoopback should automatically change to noLoopback. Upon completion, the value will automatically change to off(2)." ::= { modmSaConfigEntry 5 } modmSaConfigClkMaster OBJECT-TYPE SYNTAX INTEGER { external(2), internal(3), station (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Modem configured as Central: External - Locked to the clock signal provided by the user's equipment by user's port. Internal - Internal oscillator. Station - Station clock (is relevant only for cards). Modem configured as Remote: External - Always locked to the recovered receive clock of the HDSL line." ::= { modmSaConfigEntry 6 } modmSaConfigResetStatistics OBJECT-TYPE SYNTAX INTEGER { off(2), on (3), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "In the on state all statistics counters (including E1 counters) are zeroed. Upon completion, the value will automatically change to off(2). Modems that do not support statistics - the value will always be off (this object is not applicable for them). notApplicable - for modems with no statistics support." ::= { modmSaConfigEntry 7 } modmSaConfigActiveTs OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-write STATUS current DESCRIPTION "This object will be RO for the Remote modem. This is the number of active HDSL Time Slots, that determines user's data rate. Valid values: 1..maximum supported by the specific modem. 255 = notApplicable." ::= { modmSaConfigEntry 8 } modmSaConfigReset OBJECT-TYPE SYNTAX INTEGER { off (2), hw (3), hwAndConfig (4), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Reset of modem. hw - HW Reset. The configured values will not change. hwAndConfig - HW Reset and initializing the default values. notApplicable - for modems with no Reset support. After 'hw' or 'hwAndConfig' is Set, agent will turn the value to 'off'." ::= { modmSaConfigEntry 9 } modmSaConfigRemote OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), off (2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter enables or disables automatic configuration of the remote moden in Proxy mode." ::= { modmSaConfigEntry 10 } modmSaConfigPsType OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), ac (2), dc (3), ac-dc (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of PS." ::= {modmSaConfigEntry 11} modmSaConfigWorkMode OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), transparent (2), termination(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The work mode indicates if devices work in transparent mode or termination mode." ::= { modmSaConfigEntry 12} modmSaStatTable OBJECT-TYPE SYNTAX SEQUENCE OF ModmSaStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Status of the Central and Remote Modems." ::= { modmSa 2 } modmSaStatEntry OBJECT-TYPE SYNTAX ModmSaStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {modmSaConfigMode} ::= { modmSaStatTable 1} ModmSaStatEntry ::= SEQUENCE { modmSaStatHwTest Integer32, modmSaStatAlarms OCTET STRING, modmSaStatClkSrc INTEGER, modmSaStatAlarmsMask OCTET STRING, modmSaStatDeviceType INTEGER, modmSaStatSwVersion DisplayString, modmSaStatHwVersion DisplayString } modmSaStatHwTest OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The variable contains the results of the last hardware test. It is a sum of 2**n where n is as follows: 0 - EPROM Failure (or Database chksum error) 1 - I/O Expander Error 2 - Counter Error 3 - HDSL Framer Failure 4 - Transceiver Failure 5 - NVRAM Failure (applicable only for HCD-E1>=r3) 6 - NSFIFO Failure (applicable for HCD-E1>=r3 and HCD-4) 7 - BERT Failure (applicable only for HCD-E1>=r3) 8 - E1 Framer Failure (applicable only for HCD-E1>=r3) 9 - XRT Failure (applicable only for HCD-E1>=r3) 10- HDSL Framer 1 Failure (applicable only for HCD-4) 11- HDSL Framer 2 Failure (applicable only for HCD-4) 12- DSP 1 Failure (applicable only for HCD-4) 13- DSP 2 Failure (applicable only for HCD-4) 14- XRT 1 Failure (applicable only for HCD-4) 15- XRT 2 Failure (applicable only for HCD-4) if the variable is 0 then there are No Errors " ::= { modmSaStatEntry 1} modmSaStatAlarms OBJECT-TYPE SYNTAX OCTET STRING (SIZE(10)) MAX-ACCESS read-only STATUS current DESCRIPTION "The variable contains the status of the Alarms in the alarm buffer. For bit location of each Alarm in the OctetString see Modem's specification. If the value is 0 then there are No 'On' Alarms in the alarm buffer." ::= { modmSaStatEntry 2} modmSaStatClkSrc OBJECT-TYPE SYNTAX INTEGER { master (1), fallback (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This entry indicates the source of the modem clock." ::= { modmSaStatEntry 3} modmSaStatAlarmsMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE(10)) MAX-ACCESS read-write STATUS current DESCRIPTION "This variable uses to mask alarms. Location of each Alarm Mask in the OctetString, is identical to the Alarm OctetString. If the value is 0 then none of the alarms is masked." ::= { modmSaStatEntry 4} modmSaStatDeviceType OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), amc102SA (2), amc102Card (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This entry indicates the device type (or utility)." ::= { modmSaStatEntry 5} modmSaStatSwVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Display String of the modem SW version. Format: W. X Y Z 0..9 0..99 A,B,E 0..99 (Z+P are optional.) A=alpha, B=beta, E=end of development. Examples: 2.23A8 3.4 " ::= {modmSaStatEntry 6} modmSaStatHwVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Display String of the modem HW version." ::= {modmSaStatEntry 7} modmSaAlarmBuffTable OBJECT-TYPE SYNTAX SEQUENCE OF ModmSaAlarmBuffEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The alarm buffer of the Central and Remote Modems." ::= { modmSa 3 } modmSaAlarmBuffEntry OBJECT-TYPE SYNTAX ModmSaAlarmBuffEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {modmSaConfigMode,modmSaAlarmBuffIndex} ::= { modmSaAlarmBuffTable 1} ModmSaAlarmBuffEntry ::= SEQUENCE { modmSaAlarmBuffIndex Integer32, modmSaAlarmBuffCode Integer32, modmSaAlarmBuffTime DisplayString, modmSaAlarmBuffState INTEGER } modmSaAlarmBuffIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the alarm buffer Table." ::= { modmSaAlarmBuffEntry 1} modmSaAlarmBuffCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The code of the alarm. For text description of each Alarm code see Modem's specification." ::= { modmSaAlarmBuffEntry 2} modmSaAlarmBuffTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The time stamp at which the alarm has occurred. The format is hh:mm:ss " ::= { modmSaAlarmBuffEntry 3} modmSaAlarmBuffState OBJECT-TYPE SYNTAX INTEGER { off(2), on(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The new status of the alarm." ::= { modmSaAlarmBuffEntry 4} -- Modem parameters - all parameters refer the Agent itself only modmSaParam OBJECT IDENTIFIER ::= {modmSa 4} modmSaMode OBJECT-TYPE SYNTAX INTEGER { central (1), remote (2), remote2 (3), remote3 (4), remote4 (5), remote5 (6), remote6 (7), remote7 (8), remote8 (9), remote9 (10), remote10 (11) } MAX-ACCESS read-only STATUS current DESCRIPTION "The agent's current mode. For AMC 102 remote means regenerator. There can be some regenerators connecting one by the other." ::= {modmSaParam 1} modmSaFarEndIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The IP address of the agent on the far end. If the Remote modem is NOT an agent, the variable will be 0.0.0.0. Set - will be enabled only to a Central modem that works as Proxy." ::= {modmSaParam 2} modmSaFarEndType OBJECT-TYPE SYNTAX INTEGER { unknown (1), sa (2), --same product as near-end card (3), --same product as near-end saLowCost (4), --same product as near-end hcdSa (5), hcdSaL (6), hcdCard (7), htu2Sa (8), htu2Card (9), htuE1Sa (10), htuE1SaL (11), htuE1Card(12), hcd4Sa (13), hcdPF (14), unmanaged(100) --MP/DXC card } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of the Far-End modem." ::= {modmSaParam 3} modmSaRptrType OBJECT-TYPE SYNTAX INTEGER { none (2), hrpt (3), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Repeater between the Near and Far modem. none - no repeater exists between the modems. notApplicable - for modems that do not support this feature." ::= {modmSaParam 4} modmSaLearnLineMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), manually (2), automatic (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter is for the central unit only. Indicates if learn the regenerator order and number every time there is a fail in line or manually by user." ::= {modmSaParam 5} modmSaNumOfUnits OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object will hold the number of regenerators in the line." ::= {modmSaParam 6} -- Repeater Table modmSaRptrTable OBJECT-TYPE SYNTAX SEQUENCE OF ModmSaRptrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Repeaters parameters known to the central modem." ::= { modmSa 5 } modmSaRptrEntry OBJECT-TYPE SYNTAX ModmSaRptrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {modmSaIndex, modmSaRptrIndex} ::= { modmSaRptrTable 1} ModmSaRptrEntry ::= SEQUENCE { modmSaIndex Integer32, modmSaRptrIndex Integer32, modmSaRptrTest INTEGER, modmSaRptrActiveAlarms OCTET STRING, modmSaRptrAlrClear INTEGER, modmSaRptrVersion DisplayString } modmSaIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique number to identify the modem that reports about the repeater." ::= {modmSaRptrEntry 1} modmSaRptrIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Repeater." ::= { modmSaRptrEntry 2 } modmSaRptrTest OBJECT-TYPE SYNTAX INTEGER { none (1), loopLHrpt (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The possible loopbacks." ::= { modmSaRptrEntry 3 } modmSaRptrActiveAlarms OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Status of the Alarms. Each bit represents a specific alarm . For bit location of each alarm in the Octet String see modem's specification. If the value is 0 then there are No Alarms." ::= { modmSaRptrEntry 4 } modmSaRptrAlrClear OBJECT-TYPE SYNTAX INTEGER { off (1), on (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to on, clears all the active (On) alarms of the repeater. Upon completion, the value will automatically change to off(2).." ::= { modmSaRptrEntry 5 } modmSaRptrVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "SW/HW version of the repeater" ::= { modmSaRptrEntry 6 } --modmHub OBJECT IDENTIFIER ::= {modmSystem 2} --Modem - Hub Parameters modmHubParam OBJECT IDENTIFIER ::= {modmHub 1} modmHubTermConnect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Status: is the Terminal connected or not." ::= {modmHubParam 1} modmHubController OBJECT-TYPE SYNTAX INTEGER { nms (1), terminal (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selection of Hub controller during normal operation. If 'terminal' is selected, NMS can still return control to itself by setting this object to 'nms'. While terminal is the controller, NMS can perform Get operations and Set trap masks." ::= {modmHubParam 2} modmHubId OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2)) MAX-ACCESS read-write STATUS current DESCRIPTION "4 Hex characters, identifying the Hub. The last two characters (least significant) will be displayed on the Hub's CL card by a 7 segment display." ::= {modmHubParam 3} modmHubT1E1 OBJECT-TYPE SYNTAX INTEGER { other (1), t1 (2), e1 (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The T1/E1 value determines the Hub's clock rate." ::= {modmHubParam 4} modmHubClockSource OBJECT-TYPE SYNTAX INTEGER { other (1), external (2), internal (3), g703Section10 (4), receive (5), station (6) } MAX-ACCESS read-write STATUS current DESCRIPTION "Clock source." ::= {modmHubParam 5} modmHubClockRate OBJECT-TYPE SYNTAX INTEGER { e1r2048000 (1), e1r1024000 (2), e1r512000 (3), e1r256000 (4), e1r128000 (5), e1r64000 (6), e1r32000 (7), e1r16000 (8), e1r8000 (9), t1r1544000 (31), t1r772000 (32), t1r386000 (33), t1r193000 (34), t1r96500 (35), t1r48250 (36), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Clock Rate in bps. The rates are the original T1/E1 rates or the rates divided by 2n. For modmHubT1E1=e1, instances (1)-(9) are applicable. For modmHubT1E1=t1, instances (31)-(36) are applicable. For modmHubT1E1=other, instance (255) is applicable." ::= {modmHubParam 6} modmHubIpMode OBJECT-TYPE SYNTAX INTEGER { single (1), multi (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "single - Upon BootP request from S-MOD, CM-2 will assign a 'private IP' (CM-2 IP + slot number of S-MOD), which will be applicable only between the S-MOD and CM-2. multi - CM-2 assigns up to 12/24 consequent IP addresses. One for each S-MOD according to the slot number." ::= {modmHubParam 7} modmHubInstallation OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "The string will be a multiple set of 16 bit corresponds to its card position, and each set corresponds to a modem, where set #1 is the first modem on each card, and set n is the n-st modem in each card. 1........10.....16|1........10.....16| modem 1 | modem 2 | MSB LSB Bits 1-3 and 16 will be ignored. For LRS-52 detailed bit assignment see product's spec." ::= {modmHubParam 8} --Modem - Hub Alarms modmHubAlarms OBJECT IDENTIFIER ::= {modmHub 2} modmHubActiveAlarms OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Status of the Alarms for each Slot. Each bit represents a Slot of the Hub. For bit location of each Alarm in the Octet String see Hub's specification. A bit is '1' (On) if at least one 'On' alarm exists for this Slot. If the value is 0 then there are No 'On' Alarms in any Slot. For LRS52 - read 'modem' instead of the word 'slot'" ::= {modmHubAlarms 1} modmHubAlrClear OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to on, clears all the active (On) alarms of the Hub. Upon completion, the value will automatically change to off(2)." ::= {modmHubAlarms 2} modmHubMaskAlarms OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Mask of Alarms per Slot. Each bit represents a Slot of the Hub. For bit location of each Slot in the Octet String see Hub's specification (same as modmHubActiveAlarms). When a bit is '1' (On) it is masked ; all alarms of this Slot should not be sent and Alarm LED should not be lit. This mask overrides the mask on the specific alarms of each Slot or modem. If the value is 0 then all alarms should be sent. For LRS52 - read 'modem' instead of the word 'slot'." ::= {modmHubAlarms 3} modmMdl OBJECT IDENTIFIER ::= {modmSys 2} modmMdlParam OBJECT IDENTIFIER ::= {modmMdl 1} mdlParamTable OBJECT-TYPE SYNTAX SEQUENCE OF MdlParamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Parameters table of cards in the Hub." ::= { modmMdlParam 1 } mdlParamEntry OBJECT-TYPE SYNTAX MdlParamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { mdlSIdx } ::= { mdlParamTable 1} MdlParamEntry ::= SEQUENCE { mdlSIdx INTEGER, mdlSNoOfModems Integer32, mdlCardType INTEGER, mdlSPanelType INTEGER, mdlSLed OCTET STRING, mdlSActiveAlarms OCTET STRING, mdlAlrClear INTEGER, mdlSConfigMismatch INTEGER, mdlConfigSource INTEGER, mdlConfigGround INTEGER } mdlSIdx OBJECT-TYPE SYNTAX INTEGER { psA (1), psB (2), cl (3), io1 (4), io2 (5), io3 (6), io4 (7), io5 (8), io6 (9), io7 (10), io8 (11), io9 (12), io10 (13), io11 (14), io12 (15) } MAX-ACCESS read-only STATUS current DESCRIPTION "A unique number to identify a slot position in the modems Hub." ::= { mdlParamEntry 1} mdlSNoOfModems OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of modems on this card. 255 = notApplicable. " ::= { mdlParamEntry 2 } mdlCardType OBJECT-TYPE SYNTAX INTEGER { unknown (1), empty (2), ps48V (3), ps110V (4), ps230V (5), cm2 (6), smod (7), asmi24 (8), asmi31 (9), asmi32 (10), asmi50 (11), mtmi20 (12), fomi40 (13), fomiE1T1 (14), asm40cd (15), asmi50cd (16), fomi40cd (17), fomiE1T1cd (18), ps110V-24 (19), ps230V-24 (20), ps48V-24 (21), asmi31cq (22), asmi51cq (23), asmi51cd (24), asmi52cd (25), asmi52cq (26), --SMODs fomiE3 (51), fomiT3 (52), optimux4E1 (53), optimux4T1 (54), amc102 (55), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Card's type." ::= { mdlParamEntry 3 } mdlSPanelType OBJECT-TYPE SYNTAX INTEGER { empty (1), f2 (2), --rj45AndDb25 f3 (3), --rj45AndG703 f5 (5), --2*rj45And2*26HD f6 (6), --rj45+2BNCAnd2*26HD f7 (7), --asmi32 f9 (9), --rj45AndV35 f10 (10), --rj45AndRj45 f11 (11), --rj45And2rj45 f12 (12), --rj45AndX21 f13 (13), --2*rj45And2*rj45 f14 (14), --2*4381And2*rj45 f18 (15), --scsi68And4*rj11 f19 (16), --scsi68And4*TB f22 (17), --iripRj45 f20 (18), --4TB2And4RJ45 for CQ f21 (19), --4TB2AndDB25 for CQ f23 (20), --2RJ45And2IP for CD -- Panels with an Optical connector fO1 (21), --stAndDb25 fO2 (22), --stAndV35 fO3 (23), --stAndDb15 fO4 (24), --stAndG703 fO5 (25), --scAndDb25 fO6 (26), --scAndV35 fO7 (27), --scAndDb15 fO8 (28), --scAndG703 fO9 (29), --stAndEthernet fO10 (30), --scAndEthernet fO11 (31), --2*st/fcAnd2*SCSI fO12 (32), --2*st/fcAnd2*rj45 fO13 (33), --2*scAnd2*SCSI fO14 (34), --2*scAndr2*j45 fO15 (35), --(2*st/fcAnd2*4381)eth fO16 (36), --(2*scAnd2*4381)eth fO17 (37), --(2*st/fcAndBNC)e3/t3 fO18 (38), --(2*scAndBNC)e3/t3 fO19 (39), --(2*st/fcAnd2*bnc)wdm fO20 (40), --(2*scAnd2*scsi)wdm fO21 (41), --(4*MBNC And 2*st/fc)e1/t1 fO22 (42), --(4*MBNC And 2*sc)e1/t1 --Power Supply panels ps230And115 (81), --PS 230V, 115V without phantom psp230And115 (82), --PS 230V, 115V with phantom ps48 (83), --PS 48V without phantom psp48 (84), --PS 48V with phantom --Panels of CM2 card (CL) f1Cm2 (91), --CM2 UTP f2Cm2 (92), --CM2 BNC f3Cm2 (93), --CM2 V35 f4Cm2 (94), --CM2 RS-530 f5Cm2 (95), --CM2 X21 f1Cm2New (96), --CM2 UTP with embedded LEDs notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "LRS-12 Card connectors' panel type. fx - IMOD panels psxxx - PS panels fxCm2 - CM-2 panels." ::= { mdlParamEntry 4 } mdlSLed OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "LEDs status on the card . Each led will be represented by 4 bits where the first 2 bits (left) will specify the Status : (00=NA, 01=OFF, 10=ON, 11=BLINK), and the next two bits (right) will specify the Color : (00=GREEN, 01=RED, 10=YELLOW, 11=ORANGE). This object is not applicable for the 'smod', 'empty' and 'unknown' card types. For them 0 will be sent. " ::= { mdlParamEntry 5} mdlSActiveAlarms OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This object is applicable only for PS and CL cards. It gives the status of the Alarms for each Slot. Each bit represents an alarm in the slot. For bit location of each Alarm in the Octet String see Hub's specification. A bit is '1' if the alarm is On. If the value is 0 then there are No 'On' Alarms in the Slot." ::= {mdlParamEntry 6} mdlAlrClear OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to on, clears all the active (On) alarms of the Slot. Upon completion, the value will automatically change to off(2)." ::= {mdlParamEntry 7} mdlSConfigMismatch OBJECT-TYPE SYNTAX INTEGER { off (2), on (3), line1 (4), line2 (5), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object is applicable only for slots containing IMOD cards. ON - when CM-2 realizes that the configuration of the Near-End modem1 is different from that of its Far-End modem. In this case it expects user to decide which of the modems' configuration is the correct one (by 'mdlConfigSource'), or change the incorrect modem configuration. When one of these conditions is fulfilled, the value will automatically turn to OFF. Applicable for a single modem. Line1 - The same as for ON but for modem-1 line. Applicable for a double modem. Line2 - The same as for ON but for modem-2 line. Applicable for a double modem. OFF - Near-End and Far-End modems have the same configuration (OK). " ::= {mdlParamEntry 8} mdlConfigSource OBJECT-TYPE SYNTAX INTEGER { nearEnd (1), farEnd (2), nearEnd2 (3), farEnd2 (4), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is applicable only for slots containing IMOD cards, when mdlSConfigMismatch=on/on1/on2. nearEnd - Near End - 1 modem has the correct configuration farEnd - Far End - 1 has the correct configuration nearEnd - Near End - 2 has the correct configuration farEnd - Far End - 2 has the correct configuration." ::= {mdlParamEntry 9} mdlConfigGround OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disconnect (2), connect (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enables to connect or disconnect an IMOD card to the ground. disconnect - not connected to ground. connect - connected to ground. notApplicable - for other cards." ::= {mdlParamEntry 10} --mdlConfigRedundancy OBJECT-TYPE -- SYNTAX INTEGER -- { -- notApplicable (1), -- disable (2), -- enable (3) -- } -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "PS of the SA modem and/or repeaters that are connected -- to the specific module." -- ::= {mdlParamEntry 12} --Modem data - the modem can either belong to the Hub or -- be a Far-End modem connected to a modem of -- the Hub. The data applies only for IMOD cards. -- This table is used also by DXC, for data about -- far unit of each external port of DSL16 card. -- For DXC, modemIdx=ifIndex of External port of DSL16. modem OBJECT IDENTIFIER ::= {modmSys 3} modemParam OBJECT IDENTIFIER ::= {modem 1} modemParamTable OBJECT-TYPE SYNTAX SEQUENCE OF ModemParamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This parameters table is applicable only for modems that are not agents." ::= { modemParam 1 } modemParamEntry OBJECT-TYPE SYNTAX ModemParamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { modemIdx } ::= { modemParamTable 1} ModemParamEntry ::= SEQUENCE { modemIdx Integer32, modemType INTEGER, modemConfigMode INTEGER, modemModeTemporary INTEGER, modemNoOfDte Integer32, modemWire INTEGER, modemMngLink INTEGER, modemReset INTEGER, modemSlot INTEGER, modemHubId OCTET STRING, modemIpAddress IpAddress, modemPsType INTEGER, modemMaskTraps Integer32, modemActiveAlarms OCTET STRING, modemAlrClear INTEGER, modemAlrBufClear INTEGER, modemMaskSignaling OCTET STRING, modemPanelType INTEGER, modemIType INTEGER, modemRcvPower Integer32, modemSwVersion Integer32, modemLed OCTET STRING, modemRemoteType INTEGER, modemConfigPhantom INTEGER, modemRemoteTestEnable INTEGER, modemSwVerString DisplayString, modemRemoteIdx Integer32, modemHwVerString DisplayString, modemResetStatistics INTEGER, modemMaxRate INTEGER, modemBoxMaterial INTEGER } modemIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "For LRS: A unique number to identify a modem in the Hub or its far-end modem. For DXC: This will be the ifIndex of the External Port of DSL16 card, that works with this modem/product." ::= {modemParamEntry 1} modemType OBJECT-TYPE SYNTAX INTEGER { unknown (1), asmi24c (2), asmi31c (3), asmi32c (4), asmi50c (5), mtmi20c (6), fomi40c (7), fomiE1T1c (8), asm40cd (9), asmi31cq (10), asmi51cq (11), asmi51cd (12), asmi52cq (13), asmi52cd (14), asmi24r (22), asmi31r (23), asmi32r (24), asmi50r (25), mtmi20r (26), asmi24 (42), asmi31 (43), asmi32 (44), asmi50 (45), mtmi20 (46), fomi40 (47), fomiE1T1 (48), asmi51 (49), asmi52S (50), --Slave asmi52M (51), --Master lrs52 (71) } MAX-ACCESS read-only STATUS current DESCRIPTION "Modem type. xxxxxx - Stand-Alone modem. xxxxxxc - Modem on a Card within a Hub having an Agent. xxxxxxr - Modem on a Card within a Hub having no Agent. xxxxxxcd - Modem on a Double-Modem Card within a Hub having an Agent. Each modem has it's own CPU. xxxxxxcq - Modem on a Quad-Modem Card within a Hub having an Agent. One CPU for all modems. lrs52 - Modem within the LRS-52 device." ::= {modemParamEntry 2} modemConfigMode OBJECT-TYPE SYNTAX INTEGER { master (1), slave (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The mode identifies if the Modem operates as the Master unit or as the Slave unit. For modems having a jumper for this function, this object will be RO. This object can be Set only to the Master unit when modemModeTemporary=no (the Far-End unit will receive its new mode from the Central unit, via management link between the modems). Regarding other objects (except modemModeTemporary): If Modem is Master, it can perform RW operations for both Master and Slave modem. If Modem is Slave, it can perform RO operations for both Master and Slave modem." ::= {modemParamEntry 3} modemModeTemporary OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies if the Modem operates as modemConfigMode value (Master/Slave) temporarily or permanently. This object can be Set only when: - modemConfigMode=master AND modemModeTemporary=no - modemConfigMode=slave AND modemModeTemporary=yes this is an exception to the fact that all other objects in this case are RO. The other unit will receive its value for this object from the Set unit, via management link between the modems." ::= {modemParamEntry 4} modemNoOfDte OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of DTE ports in the modem." ::= {modemParamEntry 5} modemWire OBJECT-TYPE SYNTAX INTEGER { w2wire (1), w4wire (2), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Modem wiring." ::= {modemParamEntry 6} modemMngLink OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Communication status between the pair of modems." ::= {modemParamEntry 7} modemReset OBJECT-TYPE SYNTAX INTEGER { off (2), hwReset (3), configReset(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "When this object is set to the value of hwReset(3), the module performs HW Reset. When this object is set to the value of configReset(4), the modem performs Configuration Reset, which will set the modem to the last parameters it was configured." ::= {modemParamEntry 8} modemSlot OBJECT-TYPE SYNTAX INTEGER { io1 (4), io2 (5), io3 (6), io4 (7), io5 (8), io6 (9), io7 (10), io8 (11), io9 (12), io10 (13), io11 (14), io12 (15), io13 (16), io14 (17), io15 (18), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "A unique number to identify the slot position of the modem (card)in its Hub. notApplicable - for a stand-alone modem or Rack 214 card. io13..io15 - are for DXC use in case of a Far-Unit that is DSL16 card." ::= {modemParamEntry 9} modemHubId OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2)) MAX-ACCESS read-only STATUS current DESCRIPTION "4 Hex characters, identifying the Hub. The last two characters (least significant) will be displayed on the Hub's CL card by a 7 segment display. This object is applicable only for LRS-12 modems." ::= {modemParamEntry 10} modemIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "For LRS: The IP address of the LRS-12 agent . If the modem is NOT an LRS-12 card, the variable will be 0.0.0.0. For DXC: the IP Address of the Far-End unit." ::= {modemParamEntry 11} modemPsType OBJECT-TYPE SYNTAX INTEGER { ac (1), dc (2), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of PS, for a stand-alone modem. notApplicable - for LRS-12 or Rack 214 card." ::= {modemParamEntry 12} modemMaskTraps OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value determines the modem traps the agent should mask and not send to the management console. The value is a sum of 2**n, where n is a bit assigned to a certain trap. For bit assignment see modem's specification. Value of '0', means that no trap should be masked." ::= {modemParamEntry 13} modemActiveAlarms OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Status of the Alarms for each modem. Each bit represents an alarm. For bit location of each Alarm in the Octet String see modem's specification. A bit is '1' if the alarm is On. If the value is 0 then there are no 'On' alarms on this modem." ::= {modemParamEntry 14} modemAlrClear OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to on, clears all the active (On) alarms of the modem. Upon completion, the value will automatically change to off(2)." ::= {modemParamEntry 15} modemAlrBufClear OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to on, clears all the alarms in the buffer alarm of the modem. Upon completion, the value will automatically change to off(2)." ::= {modemParamEntry 16} modemMaskSignaling OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Mask of Signals per modem. When a signal is masked, the agent will not send the modemSignalingChange TRAP, upon change of this signal's value and it will not enter the History Log. Each bit represents a signal of the modem. For bit location of each signal in the Octet String see modem's specification. When a bit is '1' (On) it is masked ." ::= {modemParamEntry 17} modemPanelType OBJECT-TYPE SYNTAX INTEGER { f2 (2), --rj45AndDb25 f3 (3), --rj45AndG703 f7 (7), --asmi32 f9 (9), --rj45AndV35 f10 (10), --rj45AndRj45 f11 (11), --rj45And2rj45 f12 (12), --rj45AndX21 -- Panels with an Optical connector fO1 (21), --stAndDb25 fO2 (22), --stAndV35 fO3 (23), --stAndDb15 fO4 (24), --stAndG703 fO5 (25), --scAndDb25 fO6 (26), --scAndV35 fO7 (27), --scAndDb15 fO8 (28), --scAndG703 fO9 (29), --stAndEthernet fO10 (30), --scAndEthernet pcu (101), lcd (102), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "The panel type of the modem. This parameter is applicable only for Far-End modems that are stand-alone or cards of another LRS-12. It enables displaying the correct panel of the modem. - Stand-alone : applicable only for ASMi-24 and ASMi-50 modems. pcu - with connector for Portable Control Unit lcd - LCD display and buttons. - LRS-12 card : fx is the connectors panel of the modem. " ::= {modemParamEntry 18} modemIType OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Is the modem Intelligent (ASMi-xx) ; or not - (ASM-xx). This object is used only for the Far-End modem (with the relevant modemIdx). notApplicable - for ASMi-32, ASMi-50 no - modem is NOT I-Type so it doesn't have a management link to its pair-modem. yes - modem is I-Type so it has a management link to its pair-modem." ::= {modemParamEntry 19} modemRcvPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The Rx Level of the modem, in dBm. Valid values: -99 .. 0. 255=not applicable. " ::= {modemParamEntry 20} modemSwVersion OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SW version of the modem, multiplied by 100. Example: 115 means SW ver: 1.15 0 = notApplicable. " ::= {modemParamEntry 21} modemLed OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "LEDs status on the card . Each led will be represented by 4 bits where the first 2 bits (left) will specify the Status : (00=NA, 01=OFF, 10=ON, 11=BLINK), and the next two bits (right) will specify the Color : (00=GREEN, 01=RED, 10=YELLOW, 11=ORANGE). This object is applicable for modems located on a card that contains more than one modem. When not applicable 0 will be sent. " ::= { modemParamEntry 22} modemRemoteType OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), unknown (2), sa (3), single (4), double (5), rack (6), quad (7), saSlave (8), fcd (9), dxcCard4p (10), --DXC30 4 links - D4GSL dxcCard8p (11), --DXC30 8 links - D8GSL lrs52 (12) } MAX-ACCESS read-only STATUS current DESCRIPTION "Remote modem card type. Not applicable to near - end modems. For LRS-52, sa(3)=saMaster." ::= {modemParamEntry 23} modemConfigPhantom OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), off (2), on (3), notValid (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables to supply electric power to remote devices (SA modem, repeaters), through the current module. off - remote devices will not get PS through the current modem. on - remote devices will get PS through the current modem. notApplicable - for a modem without a phantom unit. notValid - In case the unit exists but is not functioning." ::= {modemParamEntry 24} modemRemoteTestEnable OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter identifies if the remote Modem allowed to operates tests. For Near-End modems this parameter will be ON." ::= {modemParamEntry 25} modemSwVerString OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Display String of the modem SW version. Format: X. Y Z P 0..9 0..99 A,B,E 0..99 (Z+P are optional.) A=alpha, B=beta, E=end of development. Examples: 2.23A8 3.4 " ::= {modemParamEntry 26} modemRemoteIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "0 = notApplicable. For LRS: The Remote modem index. Applicable only for modemRemoteType=double(5) or quad(7). For DXC and LRS-52: - if Remote unit is an LRS Quad card: remote modem index (1..4) - if Remote unit is a DXC DSL16 card: external port index (1..16). - if Remote unit is an LRS-52 modem: 1..24." ::= {modemParamEntry 27} modemHwVerString OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Display String of the modem HW version." ::= {modemParamEntry 28} modemResetStatistics OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "In the on state all statistics counters (including E1 counters) are zeroed. Upon completion, the value will automatically change to off(2). notApplicable - for modems with no statistics support." ::= {modemParamEntry 29} modemMaxRate OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), r2Mbps (2), r4Mbps (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum rate supported by the modem " ::= {modemParamEntry 30} modemBoxMaterial OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), plastic (2), metal (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Shape (picture) of modem box is related to box material. Applicable for ASMi52 SA " ::= {modemParamEntry 31} modemAlrBuffer OBJECT IDENTIFIER ::= {modem 2} modemAlrBufTable OBJECT-TYPE SYNTAX SEQUENCE OF ModemAlrBufEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This parameters table is applicable only for modems that are not agents." ::= { modemAlrBuffer 1 } modemAlrBufEntry OBJECT-TYPE SYNTAX ModemAlrBufEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { modemIdx, modemAlrBufIdx } ::= { modemAlrBufTable 1} ModemAlrBufEntry ::= SEQUENCE { modemAlrBufIdx Integer32, modemAlrBufCode Integer32, modemAlrBufState INTEGER, modemAlrBufDate DisplayString, modemAlrBufTime DisplayString, modemAlrBufSysUpTime TimeTicks } modemAlrBufIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Running index of the alarm buffer table." ::= {modemAlrBufEntry 1} modemAlrBufCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The code of the alarm. For text description of each Alarm code see Modem's specification." ::= {modemAlrBufEntry 2} modemAlrBufState OBJECT-TYPE SYNTAX INTEGER { off(2), on(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The new status of the alarm." ::= {modemAlrBufEntry 3} modemAlrBufDate OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The Date at which the alarm has occurred. The format is according to the entered systemDate format." ::= {modemAlrBufEntry 4} modemAlrBufTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The time stamp at which the alarm has occurred. The format is hh:mm:ss " ::= {modemAlrBufEntry 5} modemAlrBufSysUpTime OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime at the time the alarm has occurred. This object is applicable only for products that cannot support calendar date (modemAlrBufDate) and time (modemAlrBufTime) When not applicable, this object contains a zero value" ::= {modemAlrBufEntry 6} modemStatistics OBJECT IDENTIFIER ::= {modem 3} modemGeneralTable OBJECT-TYPE SYNTAX SEQUENCE OF ModemGeneralEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The IMOD General data Table. The data is specific to each modem." ::= { modemStatistics 1 } modemGeneralEntry OBJECT-TYPE SYNTAX ModemGeneralEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the modemGeneralTable. This entry is per modem. Each modem has a specific index, which identifies it." INDEX {modemIdx} ::= { modemGeneralTable 1} ModemGeneralEntry ::= SEQUENCE { modemCurrentElapsedTime Integer32, modemValidIntervals Integer32 } modemCurrentElapsedTime OBJECT-TYPE SYNTAX Integer32 (0..899) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of seconds that have elapsed since the beginning of the current error-measurement period." ::= {modemGeneralEntry 1} modemValidIntervals OBJECT-TYPE SYNTAX Integer32 (0..96) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of previous intervals for which data was collected. The value will be 96 unless the interface was brought on-line within the last 24 hours, in which case the value will be the number of complete 15 minute intervals since the interface has been online." ::= {modemGeneralEntry 2} modemIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF ModemIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The IMOD Interval Table. The data is specific to each modem." ::= { modemStatistics 2 } modemIntervalEntry OBJECT-TYPE SYNTAX ModemIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the modemIntervalTable. This entry is per modem and per interval selected." INDEX {modemIdx, modemIntervalNumber} ::= { modemIntervalTable 1} ModemIntervalEntry ::= SEQUENCE { modemIntervalNumber Integer32, modemSyncLoss Integer32, modemLineQuality INTEGER, modemLineUtility Integer32, modemRTS Integer32, modemCD Integer32, modemBertResult DisplayString, modemBpvError OCTET STRING, modemFoError OCTET STRING } modemIntervalNumber OBJECT-TYPE SYNTAX Integer32 (1..96) MAX-ACCESS read-only STATUS current DESCRIPTION "The number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid). Maximum valid number is modemValidIntervals." ::= {modemIntervalEntry 1} modemSyncLoss OBJECT-TYPE SYNTAX Integer32 (0..101) MAX-ACCESS read-only STATUS current DESCRIPTION "Percent of interval, SyncLoss signal is ON. 101 = notApplicable/unknown. " ::= {modemIntervalEntry 2} modemLineQuality OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), bad (2), mid (3), good (4), unknown (5), syncLoss(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "Quality of Line for the selected modem, in the selected valid interval." ::= {modemIntervalEntry 3} modemLineUtility OBJECT-TYPE SYNTAX Integer32 (0..101) MAX-ACCESS read-only STATUS current DESCRIPTION "Percent of interval, Line is utilized. 101 = notApplicable/unknown. " ::= {modemIntervalEntry 4} modemRTS OBJECT-TYPE SYNTAX Integer32 (0..101) MAX-ACCESS read-only STATUS current DESCRIPTION "Percent of interval, RTS signal is ON. 101 = notApplicable/unknown. " ::= {modemIntervalEntry 5} modemCD OBJECT-TYPE SYNTAX Integer32 (0..101) MAX-ACCESS read-only STATUS current DESCRIPTION "Percent of interval, CD signal is ON. 101 = notApplicable/unknown. " ::= {modemIntervalEntry 6} modemBertResult OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Result of BERT for the selected modem, in the selected valid interval." ::= {modemIntervalEntry 7} modemBpvError OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..1)) MAX-ACCESS read-only STATUS current DESCRIPTION "BPV Error. The Octet will be built as follows: MSB 7 6 5 4 3 2 1 0 LSB |__| |______________| y=0..3 x=0..63 BPV Error = x * (10**y) An Agent that does not support this object will send Size=0." ::= {modemIntervalEntry 8} modemFoError OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..1)) MAX-ACCESS read-only STATUS current DESCRIPTION "FO Error. The Octet will be built as follows: MSB 7 6 5 4 3 2 1 0 LSB |__| |______________| y=0..3 x=0..63 FO Error = x * (10**y) An Agent that does not support this object will send Size=0." ::= {modemIntervalEntry 9} modmPrt OBJECT IDENTIFIER ::= {modmSys 4} -- Supervisory Port (SP) modmSpPort OBJECT IDENTIFIER ::= {modmPrt 1} modmPrtSpTable OBJECT-TYPE SYNTAX SEQUENCE OF ModmPrtSpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Configuration parameters of the Local or Remote Modem Supervisory Ports. The port will be identified by its specific ifIndex value." ::= { modmSpPort 1 } modmPrtSpEntry OBJECT-TYPE SYNTAX ModmPrtSpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {ifIndex} ::= { modmPrtSpTable 1} ModmPrtSpEntry ::= SEQUENCE { modmPrtSpUsage INTEGER, modmPrtSpRate INTEGER, modmPrtSpDataBits INTEGER, modmPrtSpParity INTEGER, modmPrtSpInterface INTEGER, modmPrtSpCTS INTEGER, modmPrtSpDcdDelay INTEGER, modmPrtSpDsr INTEGER } modmPrtSpUsage OBJECT-TYPE SYNTAX INTEGER { nmsSlip (2), terminal (3), agentSlip (4), nmsPpp (5), agentPpp (6) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates what is the usage of the port." ::= { modmPrtSpEntry 1} modmPrtSpRate OBJECT-TYPE SYNTAX INTEGER { auto (1), s300bps (2), s1200bps (3), s2400bps (4), s4800bps (5), s9600bps (6) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the operation rate (speed) of the port. auto - automatic rate selection, by the agent." ::= {modmPrtSpEntry 2} modmPrtSpDataBits OBJECT-TYPE SYNTAX INTEGER { dataBits7 (1), dataBits8 (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the number of data bits in the word format." ::= {modmPrtSpEntry 3} modmPrtSpParity OBJECT-TYPE SYNTAX INTEGER { none (1), odd (2), even (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the parity mode in async frame" ::= { modmPrtSpEntry 4} modmPrtSpInterface OBJECT-TYPE SYNTAX INTEGER { dce (1), dte (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the supervisory port interface. dce - the modem appears as a DCE for the SP port. dte - the modem operates as a DTE, for connection via modem, for the SP port." ::= { modmPrtSpEntry 5} modmPrtSpCTS OBJECT-TYPE SYNTAX INTEGER { on (2), rts (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "CTS line state. " ::= {modmPrtSpEntry 6} modmPrtSpDcdDelay OBJECT-TYPE SYNTAX INTEGER { d0 (2), d10 (3), d50 (4), d100 (5), d200 (6), d300 (7) } MAX-ACCESS read-write STATUS current DESCRIPTION "DCD delay in msec. d10 = delay of 10msec." ::= { modmPrtSpEntry 7} modmPrtSpDsr OBJECT-TYPE SYNTAX INTEGER { on (2), dtr (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "DSR line state." ::= {modmPrtSpEntry 8} -- Ds1 Port (T1/E1) modmDs1Port OBJECT IDENTIFIER ::= {modmPrt 2} modmPrtDs1Table OBJECT-TYPE SYNTAX SEQUENCE OF ModmPrtDs1Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Statistics parameters of the Local and Remote modem Ds1 ports. The port will be identified by its specific ifIndex value." ::= { modmDs1Port 1 } modmPrtDs1Entry OBJECT-TYPE SYNTAX ModmPrtDs1Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {ifIndex} ::= { modmPrtDs1Table 1} ModmPrtDs1Entry ::= SEQUENCE { modmPrtDs1HdslPriorityBumping OCTET STRING, modmPrtDs1Sync INTEGER, modmPrtDs1BpvLastMin Gauge32, modmPrtDs1BpvMax Gauge32, modmPrtDs1LineLength INTEGER, modmPrtDs1CRCAvgError Gauge32 } modmPrtDs1HdslPriorityBumping OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "The 4 bytes represent the 32 time slots of the E1 frame. Each bit can be set to one, making the corresponding time slot a HIGH priority. Bits 16 and 32 cannot be modified by the user. The maximum number of HIGH priority time slots is 16. The default value is LOW, i.e., 0. This variable is RO in the Remote unit." -- DEFVAL { 0 } ::= { modmPrtDs1Entry 1 } modmPrtDs1Sync OBJECT-TYPE SYNTAX INTEGER { itu(2), fast(3), s62411(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The standard used for the time required for the E1 port to return to normal operation after local loss of synchronization. Default: itu(2)." -- DEFVAL { 2 } ::= { modmPrtDs1Entry 2 } modmPrtDs1BpvLastMin OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object is applicable only for an E1 active port. It provides the number of BPV (BiPolar Violation) events detected during the last minute." ::= { modmPrtDs1Entry 3 } modmPrtDs1BpvMax OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object is applicable only for an E1 active port. It provides the maximal number of BPV (BiPolar Violation) events (per minute), detected during the worst minute." ::= { modmPrtDs1Entry 4 } modmPrtDs1LineLength OBJECT-TYPE SYNTAX INTEGER { unknown (1), len0p133ft (2), len134p266ft (3), len267p399ft (4), len400p533ft (5), len534p655ft (6), fcc68 (7), notApplicable(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute is the line length mask parameter used only for T1/DSU interfaces. len400p533ft=length range: 400ft to 533ft 'fcc68' - provides compliance with the FCC 68.308 Option A output pulse mask. " ::= { modmPrtDs1Entry 5 } modmPrtDs1CRCAvgError OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Counts the average number of CRC error events per second. The average is updated every second" ::= { modmPrtDs1Entry 6 } modmHdslPort OBJECT IDENTIFIER ::= {modmPrt 3} modmPrtHdslCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF ModmPrtHdslCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The HDSL Current Table. The data collected is for the current 15-minute interval." ::= { modmHdslPort 1 } modmPrtHdslCurrentEntry OBJECT-TYPE SYNTAX ModmPrtHdslCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the HDSL Current Table. This entry is per HDSL interface (LOOP1 or LOOP2). Each modem (Central/Remote) has a specific ifIndex value for the port, which identifies it." INDEX {ifIndex} ::= { modmPrtHdslCurrentTable 1} ModmPrtHdslCurrentEntry ::= SEQUENCE { modmPrtHdslCurrentElapsedTime Integer32, modmPrtHdslCurrentESs Gauge32, modmPrtHdslCurrentSESs Gauge32, modmPrtHdslCurrentBBEs Gauge32, modmPrtHdslCurrentUASs Gauge32, modmPrtHdslCurrentNoiseMargin Integer32, modmPrtHdslCurrentAttenuation Integer32 } modmPrtHdslCurrentElapsedTime OBJECT-TYPE SYNTAX Integer32 (0..899) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of seconds that have elapsed since the beginning of the current error-measurement period." ::= { modmPrtHdslCurrentEntry 1 } modmPrtHdslCurrentESs OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Errored Seconds encountered by an HDSL interface in the current 15 minute interval. An Errored Second is any second containing one or more Errored Blocks or an occurrence of an SDP." ::= { modmPrtHdslCurrentEntry 2 } modmPrtHdslCurrentSESs OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Severely Errored Seconds encountered by an HDSL interface in the current 15 minute interval. An SES is any second containing more than 30% Errored Blocks (50 blocks) or one or more SDPs." ::= { modmPrtHdslCurrentEntry 3 } modmPrtHdslCurrentBBEs OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Background Block Errors encountered by an HDSL interface in the current 15 minute interval. A BBE is an errored block not occurring as part of an SES." ::= { modmPrtHdslCurrentEntry 4 } modmPrtHdslCurrentUASs OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Unavailable Seconds encountered by an HDSL interface in the current 15 minute interval. A UAS is any second in which a failed signal state exists. A failure state is declared when 10 consecutive SESs occur, and is cleared after 10 consecutive seconds free of an SES." ::= { modmPrtHdslCurrentEntry 5 } modmPrtHdslCurrentNoiseMargin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current noise margin in DB. This object is not an accumulative one, therefore it's value will appear only in this table." ::= { modmPrtHdslCurrentEntry 6 } modmPrtHdslCurrentAttenuation OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current attenuation in DB. This object is not an accumulative one, therefore it's value will appear only in this table." ::= { modmPrtHdslCurrentEntry 7 } modmPrtHdslIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF ModmPrtHdslIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The HDSL Interval Table. The data collected is for the last 96 completed 15-minute intervals." ::= { modmHdslPort 2 } modmPrtHdslIntervalEntry OBJECT-TYPE SYNTAX ModmPrtHdslIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the HDSL Interval Table. This entry is per an HDSL interface (LOOP1 or LOOP2) and per 15 minute interval. The port and unit (Central/Remote) is identified by its specific ifIndex value." INDEX {ifIndex, modmPrtHdslIntervalNumber} ::= { modmPrtHdslIntervalTable 1} ModmPrtHdslIntervalEntry ::= SEQUENCE { modmPrtHdslIntervalNumber Integer32, modmPrtHdslIntervalESs Gauge32, modmPrtHdslIntervalSESs Gauge32, modmPrtHdslIntervalBBEs Gauge32, modmPrtHdslIntervalUASs Gauge32, modmPrtHdslIntervalESR Integer32, modmPrtHdslIntervalSESR Integer32, modmPrtHdslIntervalBBER Integer32 } modmPrtHdslIntervalNumber OBJECT-TYPE SYNTAX Integer32 (1..96) MAX-ACCESS read-only STATUS current DESCRIPTION "The number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid)." ::= { modmPrtHdslIntervalEntry 1 } modmPrtHdslIntervalESs OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Errored Seconds encountered by an HDSL interface in one of the previous 96, individual 15 minute, intervals." ::= { modmPrtHdslIntervalEntry 2 } modmPrtHdslIntervalSESs OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Severely Errored Seconds encountered by an HDSL interface in one of the previous 96, individual 15 minute, intervals." ::= { modmPrtHdslIntervalEntry 3 } modmPrtHdslIntervalBBEs OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Background Block Errors encountered by an HDSL interface in one of the previous 96, individual 15 minute, intervals." ::= { modmPrtHdslIntervalEntry 4 } modmPrtHdslIntervalUASs OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Unavailable Seconds encountered by an HDSL interface in one of the previous 96, individual 15 minute, intervals." ::= { modmPrtHdslIntervalEntry 5 } modmPrtHdslIntervalESR OBJECT-TYPE SYNTAX Integer32 (0..100) MAX-ACCESS read-only STATUS current DESCRIPTION "The ratio of ESs to 900 seconds, encountered by an HDSL interface in one of the previous 96, individual 15 minute, intervals." ::= { modmPrtHdslIntervalEntry 6 } modmPrtHdslIntervalSESR OBJECT-TYPE SYNTAX Integer32 (0..100) MAX-ACCESS read-only STATUS current DESCRIPTION "The ratio of SESs to 900 seconds, encountered by an HDSL interface in one of the previous 96, individual 15 minute, intervals." ::= { modmPrtHdslIntervalEntry 7 } modmPrtHdslIntervalBBER OBJECT-TYPE SYNTAX Integer32 (0..100) MAX-ACCESS read-only STATUS current DESCRIPTION "The ratio of BBEs to 900 seconds, encountered by an HDSL interface in one of the previous 96, individual 15 minute, intervals." ::= { modmPrtHdslIntervalEntry 8 } modmPrtHdslTotalTable OBJECT-TYPE SYNTAX SEQUENCE OF ModmPrtHdslTotalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The HDSL Total Table. The data collected is the cumulative sum of the various statistics for the 24 hour period preceding the current interval." ::= { modmHdslPort 3 } modmPrtHdslTotalEntry OBJECT-TYPE SYNTAX ModmPrtHdslTotalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the HDSL Total Table. This entry is per an HDSL interface (LOOP1 or LOOP2). The port and unit (Central/Remote) is identified by its specific ifIndex value." INDEX {ifIndex} ::= { modmPrtHdslTotalTable 1} ModmPrtHdslTotalEntry ::= SEQUENCE { modmPrtHdslTotalValidIntervals Integer32, modmPrtHdslTotalESs Gauge32, modmPrtHdslTotalSESs Gauge32, modmPrtHdslTotalBBEs Gauge32, modmPrtHdslTotalUASs Gauge32 } modmPrtHdslTotalValidIntervals OBJECT-TYPE SYNTAX Integer32 (0..96) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of previous intervals for which valid data was collected. The value will be 96 unless the interface was brought on-line within the last 24 hours, in which case the value will be the number of complete 15 minute intervals since the interface has been online." ::= { modmPrtHdslTotalEntry 1 } modmPrtHdslTotalESs OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Errored Seconds encountered by an HDSL interface in the previous 24 hour interval." ::= { modmPrtHdslTotalEntry 2 } modmPrtHdslTotalSESs OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Severely Errored Seconds encountered by an HDSL interface in the previous 24 hour interval." ::= { modmPrtHdslTotalEntry 3 } modmPrtHdslTotalBBEs OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Background Block Errors encountered by an HDSL interface in the previous 24 hour interval." ::= { modmPrtHdslTotalEntry 4 } modmPrtHdslTotalUASs OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Unavailable Seconds encountered by an HDSL interface in the previous 24 hour interval." ::= { modmPrtHdslTotalEntry 5 } modmPrtHdslTable OBJECT-TYPE SYNTAX SEQUENCE OF ModmPrtHdslEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The HDSL Table." ::= { modmHdslPort 4 } modmPrtHdslEntry OBJECT-TYPE SYNTAX ModmPrtHdslEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the HDSL Table. The port and unit (Central/Remote) is identified by its specific modmPrtHdslIndex value." INDEX {modmPrtHdslIndex} ::= { modmPrtHdslTable 1} ModmPrtHdslEntry ::= SEQUENCE { modmPrtHdslIndex Integer32, modmPrtHdslDedicatedTs Integer32, modmPrtHdslPriorityBumping OCTET STRING, modmPrtHdslMngProtocol INTEGER, modmPrtHdslRoutProtocol INTEGER, modmPrtHdslInbandMngRate INTEGER } modmPrtHdslIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The HDSL port index. In some cases it can equal ifIndex." ::= { modmPrtHdslEntry 1} modmPrtHdslDedicatedTs OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The HDSL Current Dedicated TS. Valid values: 0..31. 255 = None (no dedicated TS)." ::= { modmPrtHdslEntry 2 } modmPrtHdslPriorityBumping OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) MAX-ACCESS read-write STATUS current DESCRIPTION "The 4 bytes represent time slots 0..31 of the E1 frame. Each bit can be set to '1', making the corresponding time slot a HIGH priority. Bit 0 is always HIGH (cannot be modified by the user). The maximum number of HIGH priority time slots is: 16 for E1 ; 13 for T1 (including TS0). The default value is LOW, i.e., 0." -- DEFVAL { 0 } ::= { modmPrtHdslEntry 3 } modmPrtHdslMngProtocol OBJECT-TYPE SYNTAX INTEGER { off (2), dedicatedTs (4), dedicatedPpp(5), dedicatedFr (6) } MAX-ACCESS read-write STATUS current DESCRIPTION "A unique number to identify an Inband management over the link." ::= { modmPrtHdslEntry 4 } modmPrtHdslRoutProtocol OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), none (2), proprietary (3), rip2 (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Inband Mng Routing Protocol of the port. When modmPrtHdslMngProtocol is 'dedicatedPpp'-'proprietary' and 'rip2' are applicable. For other values - only 'proprietary' is applicable." ::= {modmPrtHdslEntry 5} modmPrtHdslInbandMngRate OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), r4k (2), r8k (3), r12k (4), r16k (5), r32k (6), r64k (7) } MAX-ACCESS read-write STATUS current DESCRIPTION "A unique number to identify the rate of the Inband management. It is applicable only when modmPrtHdslDedicatedTs <> (255 Or 0)." ::= {modmPrtHdslEntry 6} -- DTE (User) Port modmDtePort OBJECT IDENTIFIER ::= {modmPrt 4} modmPrtDteTable OBJECT-TYPE SYNTAX SEQUENCE OF ModmPrtDteEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Configuration parameters of the Master and Slave Modem DTE Ports. The port and unit (Master/Slave) is identified by its specific modmPrtDteIndex value." ::= { modmDtePort 1 } modmPrtDteEntry OBJECT-TYPE SYNTAX ModmPrtDteEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {modmPrtDteIndex} ::= { modmPrtDteTable 1} ModmPrtDteEntry ::= SEQUENCE { modmPrtDteIndex Integer32, modmPrtDteProtocol INTEGER, modmPrtDteDataBits INTEGER, modmPrtDteStopBits INTEGER, modmPrtDteRate INTEGER, modmPrtDteCtsDelay INTEGER, modmPrtDteParity INTEGER, modmPrtDteIfType INTEGER, modmPrtDteRlbEnable INTEGER, modmPrtDteAlbEnable INTEGER, modmPrtDteRtsDcdEnable INTEGER, modmPrtDteDsrDtrEnable INTEGER, modmPrtDteSignaling OCTET STRING, modmPrtDteLoops INTEGER, modmPrtDteTests Integer32, modmPrtDteClearAllTests INTEGER, modmPrtDteBertResult DisplayString, modmPrtDteErrCorrect INTEGER, modmPrtDteV54DigitalTest INTEGER, modmPrtDteV54DigitalTestStatus INTEGER, modmPrtDteTestTimeOut Integer32 } modmPrtDteIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The DTE port index." ::= { modmPrtDteEntry 1} modmPrtDteProtocol OBJECT-TYPE SYNTAX INTEGER { sync (2), async (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The DTE port Protocol." ::= { modmPrtDteEntry 2} modmPrtDteDataBits OBJECT-TYPE SYNTAX INTEGER { dataBits6 (1), dataBits7 (2), dataBits8 (3), dataBits9 (4), dataBits10 (5), dataBits11 (6), dataBits5 (7) } MAX-ACCESS read-write STATUS current DESCRIPTION "The DTE number of data bits." ::= { modmPrtDteEntry 3} modmPrtDteStopBits OBJECT-TYPE SYNTAX INTEGER { stopBits1Bit (1), stopBits1dot5Bits (2), stopBits2Bits (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The DTE minimum number of stop bits in the tx async frame." ::= { modmPrtDteEntry 4} modmPrtDteRate OBJECT-TYPE SYNTAX INTEGER { r300bps (1), r600bps (2), r1200bps (3), r2400bps (4), r4800bps (5), r9600bps (6), r14400bps (7), r16000bps (8), r19200bps (9), r28800bps (10), r32000bps (11), r38400bps (12), r48000bps (13), r56000bps (14), r57600bps (15), r64000bps (16), r72000bps (17), r96000bps (18), r112000bps (19), r115200bps (20), r128Kbps (21), r144Kbps (22), r192Kbps (23), r256Kbps (24), r320Kbps (25), r384Kbps (26), r448Kbps (27), r512Kbps (28), r576Kbps (29), r640Kbps (30), r704Kbps (31), r768Kbps (32), r1024Kbps (33), r1536Kbps (34), r1544Kbps (35), r2048Kbps (36), e1 (37), t1 (38), r896Kbps (39), r960Kbps (40), r1152Kbps (41), r1920Kbps (42), r34Mbps (43), -- e3 r45Mbps (44), -- t3 r1088Kbps (45), r1216Kbps (46), r1344Kbps (47), r1408Kbps (48), r1472Kbps (49), r1600Kbps (50), r1664Kbps (51), r1728Kbps (52), r1792Kbps (53), r1856Kbps (54), r1984Kbps (55), r1280Kbps (56), r2304Kbps (57), r832Kbps (58), r2176Kbps (59), r2432Kbps (60), r2560Kbps (61), r2688Kbps (62), r2816Kbps (63), r2944Kbps (64), r3072Kbps (65), r3200Kbps (66), r3328Kbps (67), r3456Kbps (68), r3584Kbps (69), r3712Kbps (70), r3840Kbps (71), r3968Kbps (72), r4096Kbps (73), r2112Kbps (74), r2240Kbps (75), r4224Kbps (76), r4352Kbps (77), r4480Kbps (78), r4608Kbps (79) } MAX-ACCESS read-write STATUS current DESCRIPTION "The DTE port rate." ::= { modmPrtDteEntry 5} modmPrtDteCtsDelay OBJECT-TYPE SYNTAX INTEGER { d0 (1), d1 (2), d7 (3), d8 (4), d10 (5), d70 (6), disabled (7), enabled (8), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "CTS/RTS delay, in msec. dxx = xx msec. notApplicable - for ASMi-31, ASMi-32." ::= { modmPrtDteEntry 6} modmPrtDteParity OBJECT-TYPE SYNTAX INTEGER { none (1), odd (2), even (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the parity mode in async frame." ::= { modmPrtDteEntry 7} modmPrtDteIfType OBJECT-TYPE SYNTAX INTEGER { v24 (1), rs530 (2), x21 (3), g703 (4), --E1 v36 (5), v35 (6), g703r64k (7), hdb3 (8), ethernet (9), --UTP g703T1 (10), ethBNC (11), noIR (15), ipUtp (16), ethQ (17), rs530WA (18), v35WA (19), g704E1 (20), ethQN (21), other (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "The interface type of the DTE port." ::= { modmPrtDteEntry 8} modmPrtDteRlbEnable OBJECT-TYPE SYNTAX INTEGER { disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable Remote Loop-Back on this modem, externally initiated." ::= {modmPrtDteEntry 9} modmPrtDteAlbEnable OBJECT-TYPE SYNTAX INTEGER { disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable Analog Loop-Back on this modem, externally initiated." ::= {modmPrtDteEntry 10} modmPrtDteRtsDcdEnable OBJECT-TYPE SYNTAX INTEGER { disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable RTS-DCD." ::= {modmPrtDteEntry 11} modmPrtDteDsrDtrEnable OBJECT-TYPE SYNTAX INTEGER { disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable DSR-DTR." ::= {modmPrtDteEntry 12} modmPrtDteSignaling OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Each bit represents a specific signal state. 1 - means : signal is ON , Enabled, Yes (exists) 0 - means : signal is OFF, Disabled, No . For detailed bit assignment see product's spec." ::= {modmPrtDteEntry 13} modmPrtDteLoops OBJECT-TYPE SYNTAX INTEGER { none (1), ana (2), rem (3), anaAndBert (4), remAndBert (5), bert (6), twoBerts (7), digital (8), dual (9), clb (10), clbAndBert (11) } MAX-ACCESS read-write STATUS current DESCRIPTION "Loops that can be run on the DTE port. none - no loop (stop running loop) ana - Local Analog Line loop rem - Remote Analog Line loop anaAndBert - ana & BERT together remAndBert - rem & BERT together bert - BERT test twoBerts - 2 BERT test digital - A remote loop on the local modem. dual - Remote loop and ana loop. clb - Local loop on the DTE connection. Must be set together with modmPrtDteTestTimeOut parameter. Applicable to asmi51/CQ/CD. clbAndBert - CLB & BERT together. Applicable to asmi51/CQ/CD. " ::= {modmPrtDteEntry 14} modmPrtDteTests OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This is a mask which indicates - for Get: which tests are running on the DTE port. - for Set: tests the user wishes to start or stop. Each test has its specific bit. - '1' means the test runs (Set: should run). - '0' means the test does not run (Set: should stop): TEST BIT ----------- --- LEDs 0 e.g : If the return value is 1 the LEDs test is running." ::= {modmPrtDteEntry 15} modmPrtDteClearAllTests OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to on, clears all the running loops and tests of the DTE port. Upon completion, the value will automatically change to off(2)." ::= {modmPrtDteEntry 16} modmPrtDteBertResult OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Result of BERT for the selected DTE port. Applicable only if BERT is running on the DTE port." ::= {modmPrtDteEntry 17} modmPrtDteErrCorrect OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), off (2), on (3), onBurst (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "notApplicable - for modems that do not support this object on - will start a random error correction process. onBurst - will start a burst error correction process. Setting this object to 'off', will stop any kind of error correction process." ::= {modmPrtDteEntry 18} modmPrtDteV54DigitalTest OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disable(2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables to start a remote digital loopback upon recognition of a special pattern. disable - will not start a digital loopback when a special pattern is recognized. enable - will start a loopback upon recognition of a special pattern." ::= {modmPrtDteEntry 19} modmPrtDteV54DigitalTestStatus OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), off (2), on (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether a remote digital test was triggered by a pattern by the remote modem or not. no - the digital test wasn't triggered by a pattern by the remote modem. yes - the digital test was triggered by a pattern by the remote modem." ::= {modmPrtDteEntry 20} modmPrtDteTestTimeOut OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the timeout for LLB test. 0=Forever " ::= {modmPrtDteEntry 21} -- Line port modmLinePort OBJECT IDENTIFIER ::= {modmPrt 5} modmPrtLineTable OBJECT-TYPE SYNTAX SEQUENCE OF ModmPrtLineEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Configuration parameters of the Master and Slave Modem Line Ports. The port and unit (Master/Slave) is identified by its specific modmPrtLineIndex value." ::= { modmLinePort 1 } modmPrtLineEntry OBJECT-TYPE SYNTAX ModmPrtLineEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {modmPrtLineIndex} ::= { modmPrtLineTable 1} ModmPrtLineEntry ::= SEQUENCE { modmPrtLineIndex Integer32, modmPrtLineClkSrc INTEGER, modmPrtLineTxLevel INTEGER, modmPrtLineRxLevel INTEGER, modmPrtLineOutImp INTEGER, modmPrtLineInImp INTEGER, modmPrtLineCarrCntrl INTEGER, modmPrtLineRAP INTEGER, modmPrtLineWaveLength INTEGER, modmPrtLineCdSense INTEGER, modmPrtLineAIS INTEGER, modmPrtLineCoding INTEGER, modmPrtLineLength INTEGER, modmPrtLineClkSrcPort INTEGER, modmPrtLineDteClkConfig INTEGER, modmPrtLineMaskAlr INTEGER } modmPrtLineIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The Line port index." ::= {modmPrtLineEntry 1} modmPrtLineClkSrc OBJECT-TYPE SYNTAX INTEGER { localExtRemoteRcv (1), localIntRemoteRcv (2), localRcvRemoteInt (3), localRcvRemoteExt (4), localExtAutoRemoteRcv (5), localRcvRemoteExtAuto (6), localSysRemoteRcv (7), localRcvRemoteSys (8), internal (9), external (10), system (11), receive (12), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "The clock source of the Line port. (5),(6) - applicable only for ASMi-24 and ASMi-50. (7),(8) - System level Clock Source. Applicable to CQ modems." ::= {modmPrtLineEntry 2} modmPrtLineTxLevel OBJECT-TYPE SYNTAX INTEGER { n12 (1), n9 (2), n6 (3), n3 (4), p0 (5), p4 (6), p6 (7), p10 (8) } MAX-ACCESS read-write STATUS current DESCRIPTION "Transmit level in dBm. pxx = positive xx = +xx nxx = negative xx = -xx " ::= {modmPrtLineEntry 3} modmPrtLineRxLevel OBJECT-TYPE SYNTAX INTEGER { n14 (1), n12 (2), n10 (3), n9 (4), n6 (5), n3 (6), p0 (7), low (8), high (9) } MAX-ACCESS read-write STATUS current DESCRIPTION "Rx Sensitivity in dBm. pxx = positive xx = +xx nxx = negative xx = -xx." ::= {modmPrtLineEntry 4} modmPrtLineOutImp OBJECT-TYPE SYNTAX INTEGER { infinite (1), i75ohm (2), i100ohm (3), i120ohm (4), i150ohm (5), i300ohm (6), i600ohm (7) } MAX-ACCESS read-write STATUS current DESCRIPTION "Output impedance in Ohm." ::= {modmPrtLineEntry 5} modmPrtLineInImp OBJECT-TYPE SYNTAX INTEGER { infinite (1), i75ohm (2), i100ohm (3), i120ohm (4), i150ohm (5), i300ohm (6), i600ohm (7) } MAX-ACCESS read-write STATUS current DESCRIPTION "Input impedance in Ohm." ::= {modmPrtLineEntry 6} modmPrtLineCarrCntrl OBJECT-TYPE SYNTAX INTEGER { off (2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Carrier control." ::= {modmPrtLineEntry 7} modmPrtLineRAP OBJECT-TYPE SYNTAX INTEGER { private (1), v110 (2), v220 (3), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Rate Adapting Protocol." ::= {modmPrtLineEntry 8} modmPrtLineWaveLength OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), nm850 (2), nm1300 (3), nm780Laser (4), nm1300Laser (5), nm1550Laser (6) } MAX-ACCESS read-only STATUS current DESCRIPTION "Wave Length of the optical Line. notApplicable - when the modem Line is not optical. The units are nano-meters [nm]." ::= {modmPrtLineEntry 9} modmPrtLineCdSense OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), high (2), low (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Carrier Detect Sense - Detection Sensitivity of Carrier Wave. high - high sensitivity low - low sensitivity. " ::= {modmPrtLineEntry 10} modmPrtLineAIS OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "AIS enable/disable. notApplicable - for modems that do not support this feature." ::= {modmPrtLineEntry 11} modmPrtLineCoding OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), ami (2), hdb3 (3), b8zs (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Line Coding." ::= {modmPrtLineEntry 12} modmPrtLineLength OBJECT-TYPE SYNTAX INTEGER { unknown (1), len0p133ft (2), len134p266ft (3), len267p399ft (4), len400p533ft (5), len534p655ft (6), notApplicable(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute is the line length mask parameter used only for T1/DSU interfaces. len400p533ft=length range: 400ft to 533ft." ::= {modmPrtLineEntry 13} modmPrtLineClkSrcPort OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), modem1 (2), modem2 (3), modem3 (4), modem4 (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Clock Source Port. This parameter is relevant for external clock source." ::= {modmPrtLineEntry 14} modmPrtLineDteClkConfig OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), dceExternal (2), dce (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the clock source of the modems, which were not selected to supply the external clock." ::= {modmPrtLineEntry 15} modmPrtLineMaskAlr OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), dontMask (2), mask (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter determine whether masking or not the alarms for this line." ::= {modmPrtLineEntry 16} -- Traps --NOTIFICATIONS modmSaEvents OBJECT-IDENTITY STATUS current DESCRIPTION "The events for Stand Alone Modems." ::= { modmSa 0 } modmSysEvents OBJECT-IDENTITY STATUS current DESCRIPTION "The events for General Modems." ::= { modmSys 0 } modmSAlarmTrap NOTIFICATION-TYPE OBJECTS {modmSaStatAlarms} STATUS current DESCRIPTION "The trap is sent every 5 seconds in which a change has occurred in the status of the variables sent. For modems containing a T1/E1 interface, dsx1LineStatus will be sent as well in the variables, after modmSaStatAlarms. This trap is applicable for Stand-alone modems or Agents that are cards of a Hub." ::= { modmSaEvents 1 } modmSLedTrap NOTIFICATION-TYPE OBJECTS {agnLed} STATUS current DESCRIPTION "The trap is sent every 5 seconds in which a change has occurred in the state of one of the LEDs. This trap is applicable for Stand-Alone modems or Agents that are cards of a Hub. 'agnLed' - will include both central and remote modems: first central, last remote." ::= { modmSaEvents 2 } -- the following traps are for a modems-Hub or IMOD modems modmHubConfigChange NOTIFICATION-TYPE OBJECTS {mdlCardType, mdlSPanelType} STATUS current DESCRIPTION "The trap is sent when any card of the modems Hub is inserted or removed." ::= { modmSysEvents 3 } modemMasterSlaveComm NOTIFICATION-TYPE OBJECTS {modemMngLink} STATUS current DESCRIPTION "This trap is applicable only for IMOD modems . The trap is sent when communication between a Master modem and its Slave is stopped or resumed. 'modemMngLink' includes the modemIdx." ::= { modmSysEvents 4 } modemMasterChange NOTIFICATION-TYPE OBJECTS {modemConfigMode, modemModeTemporary} STATUS current DESCRIPTION "This trap is applicable only for IMOD modems . The trap is sent when a modem's permanent or temporary mode is changed. 'modemConfigMode' and 'modemModeTemporary' include the modemIdx." ::= { modmSysEvents 5 } mngmntControlChange NOTIFICATION-TYPE OBJECTS {modmHubController} STATUS current DESCRIPTION "This trap is applicable only for LRS-12. The trap is sent when the Hub management controller is changed (NMS<->Terminal)." ::= { modmSysEvents 6 } modemInvalidParameter NOTIFICATION-TYPE OBJECTS {modemIdx} STATUS current DESCRIPTION "This trap is applicable only for IMOD cards of a Hub. The trap is sent when an invalid parameter was Set to the modem." ::= { modmSysEvents 7 } modemAlarm NOTIFICATION-TYPE OBJECTS {modemActiveAlarms} STATUS current DESCRIPTION "This trap is applicable only for IMOD modems . The trap is sent when the active alarms of an IMOD modem, change." ::= { modmSysEvents 8 } cardStatusChange NOTIFICATION-TYPE OBJECTS {mdlSLed} STATUS current DESCRIPTION "The trap is sent upon any change of the Leds status in the PS, CL or IMOD cards." ::= { modmSysEvents 9 } modemSignalingChange NOTIFICATION-TYPE OBJECTS {modmPrtDteSignaling} STATUS current DESCRIPTION "The trap is sent for any IMOD modem, when an unmasked signal change occured in the attached variable (see modemMaskSignaling object)." ::= { modmSysEvents 10 } modmHubPsFail NOTIFICATION-TYPE OBJECTS {mdlSLed} STATUS current DESCRIPTION "The trap is sent when a PS card of the modems-Hub failed. 'mdlSLed' includes the mdlSIdx." ::= { modmSysEvents 11 } modmHubIPModeChange NOTIFICATION-TYPE OBJECTS {modmHubIpMode} STATUS current DESCRIPTION "The trap is sent upon any change of modmHubIpMode parameter." ::= { modmSysEvents 12 } modmInterfaceChange NOTIFICATION-TYPE STATUS current DESCRIPTION "The trap is sent upon any change of interfaces for a modem that is a card of a Hub or part of it. In order to know what changed, for each product, specific variables will be attached. These variables will be specified in the product's spec. For FOMi-E3/T3 and Optimux-4E1/T1-C : the trap will be sent when the connectors card in LRS is removed/inserted." ::= { modmSysEvents 13 } modmRackAlarms NOTIFICATION-TYPE STATUS current DESCRIPTION "The trap is applicable for LRS-52. The trap is sent when an alarm occurs. Attached variables are detailed in product specification." ::= { modmSysEvents 14 } -- -- file :v:\doc\rdv\mib\ver485\dacs.txt -- --Title: RAD's DACS PRODUCTS MIB --Version: 3.0 --Date: 27.04.95 --By: Smadar Tauber --File: dacs.txt -- --Last update: 11-Aug-2002 Shlomo Shoham dacsMux OBJECT IDENTIFIER ::= {radWan 3} systemDacsMux OBJECT IDENTIFIER ::= {dacsMux 1} mdlDacsMux OBJECT IDENTIFIER ::= {dacsMux 2} prtDacsMux OBJECT IDENTIFIER ::= {dacsMux 3} genDacsMux OBJECT IDENTIFIER ::= {dacsMux 4} --System level of DACS MIB -- --Sa - data specific to a stand-alone unit --Hub - data specific to a Hub unit --Rest of the branches are common to both types of units. sysSa OBJECT IDENTIFIER ::= {systemDacsMux 1} sysHub OBJECT IDENTIFIER ::= {systemDacsMux 2} sysStatus OBJECT IDENTIFIER ::= {systemDacsMux 3} sysCurrentAlr OBJECT IDENTIFIER ::= {systemDacsMux 4} sysBufferAlr OBJECT IDENTIFIER ::= {systemDacsMux 5} sysConfig OBJECT IDENTIFIER ::= {systemDacsMux 6} sysDbase OBJECT IDENTIFIER ::= {systemDacsMux 7} --Stand-alone specific parameters sysSaSwchStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the status of the switches on the SA unit. Each switch is represented by a bit. The status is a sum of 2**n, according to the bits. For SMODs products see modem's specification. For DXC product see the following: There are 4 switches: bit 0 SP-PAR (LSB) '1' - Default parameters bit 1 PSWRD '1' - Password=default '0' - Password=user selected bit 2 DB-INIT '1' - DB initiated with default '0' - DB initiated with NVRAM contents bit 3 PC-SP (MSB) '1' - Management by terminal only '0' - Management by NMS Example: If SP-PAR and PSWRD bits are set ('1'), the value will be 3 (2**1 + 2**0). When the status of the switches is unknown, the value of this object will be 255." ::= { sysSa 1} sysSaSwRevision OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Software revision of the system." ::= {sysSa 2} sysSaHwVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Hardware version of the system." ::= {sysSa 3} sysSaPorts OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the ports that are present in the system. Each possible port is represented by a bit. The value of this object is a sum of 2**n, n=number of bits. '1' - means that the port exists '0' - means that the port does not exist For detailed bit assignment, see product's spec. Bit 0 = LSB When this object is not relevant, the value will be 0. In some cases, this object may represent ports configuration of the system AND its far-end unit." ::= {sysSa 4} sysSaReadSwch OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates wether the configuration will be read from the DIP switches on the SA (stand alone) unit. Each switch is represented by a bit. If the bit is 1: the configuration will be read from the HW switch position. If the bit is 0: the configuration will be read from the SW user configuration. The DIP switches are different in each of the RAD devices. In the Tiny Router (starting from the LSB) the following switches exist: Bit 0: WAN Loop Bit 1: LAN Full Duplex (When LAN AUI connector, it is SQE) Bit 2: PPP (When WAN 4 Wire connector, it is LONG) Bit 3: IP Learn" ::= {sysSa 5} --Hub specific parameters --Hub Cassis data sysChas OBJECT IDENTIFIER ::= {sysHub 1} chassTotalNoOfSlt OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the number of physical slots in the Hub chassis." ::= { sysChas 1 } chassTotalNoOfIoSlt OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the total number of physical IO slots in the chassis, (not all slots must be occupied and active)." ::= { sysChas 2 } chassTotalNoOfPsSlt OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the number of physical Power Supply slots in the chassis." ::= { sysChas 3 } chassTotalNoOfClSlt OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the number of physical Common Logic slots in the chassis." ::= { sysChas 4 } chassTotalNoOfMlSlt OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the number of physical Main Link slots in the chassis (Kmux)." ::= { sysChas 5 } --Hub DCL parameters sysDcl OBJECT IDENTIFIER ::= {sysHub 2} sysDclTable OBJECT-TYPE SYNTAX SEQUENCE OF SysDclEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "All the entries of this table are identical (have the same value) for all the configurations (1..255) except the TmpCnfg. The write operation into the Table Objects is valid only for the TmpCnfg entry." ::= { sysDcl 1} sysDclEntry OBJECT-TYPE SYNTAX SysDclEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {sysDclCnfgIdx} ::= { sysDclTable 1} SysDclEntry ::= SEQUENCE { sysDclCnfgIdx Integer32, sysDclRedundancy INTEGER, sysDclActiveCl INTEGER, sysDclFlipDelay INTEGER, sysDclFlipUponStnClk INTEGER } sysDclCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Idx of the Cnfg(1..255) being accessed ; Idx of 255 relates to the TmpCnfg. This object is identical for all the configurations (1..255). Only the TmpCnf(255) might have a different value." ::= { sysDclEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. sysDclRedundancy OBJECT-TYPE SYNTAX INTEGER { off (2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION " DCL redundancy desired state." ::= {sysDclEntry 2} sysDclActiveCl OBJECT-TYPE SYNTAX INTEGER { auto (1), dclA (2), dclB (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Active desired DCL. When 'auto' is selected, the system automatically selects the active DCL." ::= {sysDclEntry 3} sysDclFlipDelay OBJECT-TYPE SYNTAX INTEGER { t1min (1), t2min (2), t3min (3), t4min (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "If one DCL flip occured and a second one should be performed, the time from the previous flip is checked. If the time is shorter than the delay specified here (in minutes), the system should delay the flip operation until time reaches the specified delay." ::= {sysDclEntry 4} sysDclFlipUponStnClk OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object allows user to decide (yes/no) if Agent should Flip from one DCL card to another, when there is Station Clock Fail in the Online DCL card." ::= {sysDclEntry 5} sysDclOnline OBJECT-TYPE SYNTAX INTEGER { dclA (1), dclB (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The active Dcl card of the agent." ::= {sysDcl 2} sysDclCopyDbTable OBJECT-TYPE SYNTAX SEQUENCE OF SysDclCopyDbEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table enables to copy a cofiguration from the Offline Dcl to the Online Dcl." ::= { sysDcl 3} sysDclCopyDbEntry OBJECT-TYPE SYNTAX SysDclCopyDbEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {sysDclCopyDbIdx} ::= { sysDclCopyDbTable 1} SysDclCopyDbEntry ::= SEQUENCE { sysDclCopyDbIdx Integer32, sysDclCopyDbCmd INTEGER } sysDclCopyDbIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Idx of the Cnfg(1..255) being accessed. " ::= { sysDclCopyDbEntry 1} sysDclCopyDbCmd OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "When this command is sent to the agent, on(3), the Database specified (Db Idx), will be copied from the Offline Dcl to the Online Dcl. Afterwards the value of this object will automatically change to off(2). " ::= { sysDclCopyDbEntry 2} --General System - General Status parameters sysSDateFormat OBJECT-TYPE SYNTAX INTEGER { ddMMYYYY (1), mmDDYYYY (2), yyyyMMDD (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the date and time format used for the sysSDateAndTimeCmd and for the alarm buffer report." ::= { sysStatus 1 } sysSDateCmd OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the current date as it is known by the agent using its own real-time clock. The format would be as specified by the sysSDateFormat. This parameter can be set for time synchronization between the NMS and the Agent. * For KM-2100 V1 and FCD-T1/E1 - the string should contain '/' signs between day, month and year. Example: 12/08/1998. * For DXC and rest of the products - the string should contain '-' signs between day, month and year. Example: 12-08-1998. The day value will be in the range: 1..31. The month value will be in the range: 1..12. The year value will be in the range: 1996..2050 for products supporting the '-' format." ::= { sysStatus 2 } sysSTimeCmd OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the current time as it is known by the agent using its own real-time clock. This parameter can be set for time synchronization between the NMS and the Agent. The string should contain ':' signs between hour, minute and second. Example: 11:05:58." ::= { sysStatus 3 } sysSActiveCnfg OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the configuration number, that is currently active and running." ::= { sysStatus 4 } -- return 1 (db1) in phase I sysSEditCnfg OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the unique configuration number that is currently loaded into the tmp working space for manipulation and update operations. Value of 255 means no config. is under editing process." ::= { sysStatus 5 } -- return 1 (db1) in phase I sysSEditBy OBJECT-TYPE SYNTAX INTEGER { none (1), snmp (2), terCon1 (3), terCon2 (4), terInbandCon1 (5), terInbandCon2 (6), lcd (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "This entry indicates which MMI application is working on the edited config. The editing phase starts at the first modify operation and ends after a load operation." ::= { sysStatus 6 } sysSClkSrc OBJECT-TYPE SYNTAX INTEGER { master (1), fallback(2), internal(3), ml (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This entry indicates the source of the system clock." ::= { sysStatus 7 } sysSAlrStatus OBJECT-TYPE SYNTAX INTEGER { off (2), major (3), minor (4), event (5), warning (6), critical (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current alarm state only for system level. This object will be : - critical(7): when there is at least one active (ON) critical alarm . - major (3): when there is no active critical alarm, but there is at least one active (ON) major alarm . - minor (4): when there is no active major or critical alarm, but there is at least one active minor alarm. - warning (6): when there is no active major, critical or minor alarm, but there is at least one active warning alarm. - event (5): when there is no active alarm of another type, but there is at least one active event alarm. - off(2): when there is no active (ON) alarm (since last clear operation)." ::= { sysStatus 8 } sysSAlrStatusAll OBJECT-TYPE SYNTAX INTEGER { off (2), major (3), minor (4), event (5), warning (6), critical (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current alarm state including all levels: system, card, port. - critical(7): when there is at least one active (ON) critical alarm . - major (3): when there is no active critical alarm, but there is at least one active (ON) major alarm . - minor (4): when there is no active major or critical alarm, but there is at least one active minor alarm. - warning (6): when there is no active major, critical or minor alarm, but there is at least one active warning alarm. - event (5): when there is no active alarm of another type, but there is at least one active event alarm. - off(2): when there is no active (ON) alarm (since last clear operation)." ::= { sysStatus 9 } sysSTestStatus OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current test status (for all levels: system, card, port). This attribute will be set to: - on(3): when there is at least one test in progress on the system/card/port otherwise the value will be off(2)." ::= { sysStatus 10 } sysSSanityCheckStatus OBJECT-TYPE SYNTAX INTEGER { unknown (1), fail (2), warning (3), ok (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Upon completion of the Sanity Check process on the TmpCnfg this object will be set to: - fail(2): when there is at least one error (which is not just a warning) encountered otherwise, - warning(3): when there are only warnings otherwise, - ok(4). The value should be unknown(1), if the TmpCnfg was changed after the last Sanity check." ::= { sysStatus 11 } sysSNoOfSanityCheckErr OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the number of errors/warnings discovered by the last Sanity Check process." ::= { sysStatus 12 } sysSErrListTable OBJECT-TYPE SYNTAX SEQUENCE OF SysSErrListEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= { sysStatus 13 } sysSErrListEntry OBJECT-TYPE SYNTAX SysSErrListEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { sysSErrType, sysSErrIdx} ::= { sysSErrListTable 1} SysSErrListEntry ::= SEQUENCE { sysSErrType INTEGER, sysSErrIdx Integer32, sysSErrDescription DisplayString (SIZE (0..255)) } sysSErrType OBJECT-TYPE SYNTAX INTEGER { error (1), warning (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The errors are recorded in the agent, in two separate lists, according to their type: error or warning." ::= { sysSErrListEntry 1} sysSErrIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Unique index number to identify an entry in the error or warning list . The maximum value cannot exceed the value of 'sysSNoOfSanityCheckErr' (actually, the sum of the Errors list max. index and the Warning list max. index should equal the value of'sysSNoOfSanityCheckErr')." ::= { sysSErrListEntry 2} sysSErrDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object is a full text description of the sanity check error including error code, IO slot and port numbers related to the code ." ::= { sysSErrListEntry 3} sysSMaxNoOfCnfg OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum number of configurations that can be defined and stored in the DACS agent. If the DACS agent has a large capacity, the maximum will be limited to 254." ::= { sysStatus 14 } -- return 1 (db1) in phase I sysSSelfTestResult OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The test is performed by the active Common Logic card. The result will be a sum of 2**n according to the following bit convention: For DXC: bit 0 Database 1 Checksum Error (LSB) bit 1 Database 2 Checksum Error bit 2 I/O Expander Error bit 3 Counter Error bit 4 Matrix DPR Error bit 5 PS-A 5 Volt Error bit 6 PS-A 12 Volt Error bit 7 PS-B 5 Volt Error bit 8 PS-B 12 Volt Error bit 9 EPROM Failure For FCD: bit 0 I/O Expander Error (LSB) bit 1 Counter Error bit 2 EPROM Failure bit 3 Illegal Sys Config bit 4 SFIFO bit 5 EPIC Failure (ISDN) bit 6 XL Flash Fail -- for MSDSL interface bit 7 XL MITEL Fail -- for MSDSL interface bit 8 XL Framer Fail -- for MSDSL interface bit 9 XL DSP Fail -- for MSDSL interface For LRS52 - refer to product's spec When a bit is ('1'), the error exists. When NO ERROR is encountered, this object's value will be 0." ::= { sysStatus 15 } sysSRelayState OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), off(2), on (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current state of the alarm relay. notApplicable - for agents that do not support this object." ::= { sysStatus 16 } sysSInvertedAlr OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), no (2), yes (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates if there is any Inverted alarm at any level of the system (sys, card, port). notApplicable - for agents that do not support this object." ::= { sysStatus 17 } --The following table reports all the Flip events due to I/O Redundancy --since last Clear command of the table. sysSRdnFlipTable OBJECT-TYPE SYNTAX SEQUENCE OF SysSRdnFlipEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table includes all the Flip events due to I/O Redundancy since last Clear command of this table." ::= { sysStatus 18 } sysSRdnFlipEntry OBJECT-TYPE SYNTAX SysSRdnFlipEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { sysSRdnFlipIdx} ::= { sysSRdnFlipTable 1} SysSRdnFlipEntry ::= SEQUENCE { sysSRdnFlipIdx Integer32, sysSRdnFlipSlot INTEGER, sysSRdnFlipPort Integer32, sysSRdnFlipCause DisplayString, sysSRdnFlipDate DisplayString, sysSRdnFlipTime DisplayString } sysSRdnFlipIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Unique index number to identify an entry in the Redundancy Flip list." ::= { sysSRdnFlipEntry 1} sysSRdnFlipSlot OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), io13 (17), io14 (18), io15 (19), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "The slot number from which Flip was performed." ::= { sysSRdnFlipEntry 2} sysSRdnFlipPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The port number from which Flip was performed. For DXC: For external ports the convention used will be: - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . For internal ports the convention used will be: - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . For MP: For external ports, the value will be as that of the port in the card. Example: external-3 -> 3 external-4 -> 4 For internal ports, the value will be 100 + the port in the card. Example: internal-1 -> 101 internal-4 -> 104 100=notApplicable (when Redundancy is at card level)." ::= { sysSRdnFlipEntry 3 } sysSRdnFlipCause OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The last cause that caused the Flip from the Slot (Port) of sysSRdnSlot, sysSRdnPort." ::= { sysSRdnFlipEntry 4} sysSRdnFlipDate OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Flip event Date. The format will be the one selected by user for sysSDateFormat." ::= { sysSRdnFlipEntry 5} sysSRdnFlipTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Flip event Time. The format will be hh:mm:ss." ::= { sysSRdnFlipEntry 6} sysSRdnFlipTableClearCmd OBJECT-TYPE SYNTAX INTEGER { off (2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This command, when Set to 'on', clears the Redundancy Flip table (sysSRdnFlipTable). After clear is performed, the agent will turn the value to 'off' automatically." ::= { sysStatus 19 } sysSRdnFlipCmd OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-write STATUS current DESCRIPTION "This object enables the user to send a command to the Agent, to Flip from a current Online IO card to its Redundant card. The value sent will be an Object Identifier of an entry in the sysCRdnTable. This entry defines the Redundant couple of Slots on which the Flip is applied. Setting this object, will cause the Agent to Flip from current Online card to its Redundant card. This manual flip command is applicable only for entries having Redundancy Mode=Y Cable. Agent will send the value 0 for Get." ::= { sysStatus 20} sysSBusTable OBJECT-TYPE SYNTAX SEQUENCE OF SysSBusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table includes data and status about the internal DXC BUS." ::= { sysStatus 21 } sysSBusEntry OBJECT-TYPE SYNTAX SysSBusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { sysSBusPortIdx} ::= { sysSBusTable 1} SysSBusEntry ::= SEQUENCE { sysSBusPortIdx Integer32, sysSBusStatus INTEGER, sysSBusCapturePort Integer32, sysSBusUtilization Integer32 } sysSBusPortIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The DXC BUS port number: - first two digits will be: (IO slot number+10) - last one/two digits will be the Bus port number, in odd numbers: port1 = 1 port2 = 3 Example: port2 of IO slot 11 will be: 213." ::= { sysSBusEntry 1 } sysSBusStatus OBJECT-TYPE SYNTAX INTEGER { free (1), physical(2), virtual (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Status of sysSBusPortIdx. free - not used physical - captured by the port of the card physically installed virtual - captured virtually by another port. Example: DIM port (by Destination) or by Transparent T3/E3 port." ::= { sysSBusEntry 2} sysSBusCapturePort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The Port that Captured the sysSBusPortIdx. - if sysSBusStatus=free, the value will be 'none'=0 - else, if sysSBusStatus=fixed, the value will be: sysSBusPortIdx - else, the value will be according to the port index that captured this Bus Port (according to DXC port index convention): - xx1, xx3, xx11, xx13, xx31, xx33, xx2..xx56(even numbers) - xx = (IO slot number+10) " ::= { sysSBusEntry 3} sysSBusUtilization OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Utilization of sysSBusPortIdx resources, in percent [%]." ::= { sysSBusEntry 4} --IO Redundancy - Commands sysSRdnCmdTable OBJECT-TYPE SYNTAX SEQUENCE OF SysSRdnCmdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table includes commands used for IO Redundancy." ::= { sysStatus 22 } sysSRdnCmdEntry OBJECT-TYPE SYNTAX SysSRdnCmdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {sysCRdnPrimeSlot, sysCRdnPrimePort } ::= { sysSRdnCmdTable 1} SysSRdnCmdEntry ::= SEQUENCE { sysSRdnEnforcedChannel INTEGER } sysSRdnEnforcedChannel OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), noEnforcement (2), primary (3), secondary (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This is a command to override all switching considerations and enforce use of primary/ secondary connection only. noEnforcement - cancels the state of override and goes back to usual switching considerations. Default = noEnforcement(2)." ::= {sysSRdnCmdEntry 1 } --System Current Alarm Table -- --This table contains all Events and only the major/minor alarms --whose status is ON. sysSAlrTable OBJECT-TYPE SYNTAX SEQUENCE OF SysSAlrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of system level current existing alarms ." ::= { sysCurrentAlr 1 } sysSAlrEntry OBJECT-TYPE SYNTAX SysSAlrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { sysSAlrIdx} ::= { sysSAlrTable 1} SysSAlrEntry ::= SEQUENCE { sysSAlrIdx Integer32, sysSAlrCode Integer32, sysSAlrState INTEGER, --Severity sysSAlarmMask INTEGER, sysSAlarmInvert INTEGER, sysSAlarmOnOff INTEGER, sysSAlarmCounter Integer32 } sysSAlrIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "An index number of the current system alarms." ::= { sysSAlrEntry 1 } sysSAlrCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a code related to a specific alarm description. The list of codes and their related descriptions will be sent to NMS request (for display purpose) by alrGenTable." ::= { sysSAlrEntry 2 } sysSAlrState OBJECT-TYPE SYNTAX INTEGER { event (3), minor (4), major (5), warning (6), critical (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the alarm Severity." ::= { sysSAlrEntry 3 } sysSAlarmMask OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm Mask is : on/off." ::= { sysSAlrEntry 4 } sysSAlarmInvert OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm Invert is : on/off." ::= { sysSAlrEntry 5 } sysSAlarmOnOff OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm state is : on/off." ::= { sysSAlrEntry 6 } sysSAlarmCounter OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A counter - how many times the alarm occured (ON) since last clear operation or since last Reset." ::= { sysSAlrEntry 7 } sysSAlrClearCmd OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to ON, will enforce a clear operation on the system level alarms . Upon completion, the value will automatically change to off(2)." ::= { sysCurrentAlr 2 } sysSAlrClearAllCmd OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to ON, will enforce a clear operation on all levels alarms . Upon completion, the value will automatically change to off(2)." ::= { sysCurrentAlr 3 } sysSAlrMaskAll OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "on(3) - will cause masking of all the system level alarms. These alarms will not be sent to NMS and will not be taken into account for Alarms Status. off(2) - will unmask all system level alarms except those masked via the sysSAlrMask. " ::= { sysCurrentAlr 4 } sysSAlrMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) MAX-ACCESS read-write STATUS current DESCRIPTION "This object is a mask that indicates which system level alarms are masked. The masked alarms (their bit is set to '1') are neither sent to the manager, nor taken into account for alarm status and LEDs. Bit no. = Alarm code The bits that do not belong to the system level will be 0. This object is applicable only when sysSAlrMaskAll=off (otherwise all system alarms are masked). Example: When Alarms having the codes 6 and 11 are masked, the value of this object will be 840 (hex)." ::= { sysCurrentAlr 5 } sysSAlrDataUpdateCmd OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "on(3) - will cause Update of the Alarms Severity, Attributes and Report tables. off(2) - Upon completion, the value will automatically change to off(2)." ::= { sysCurrentAlr 6 } --System Buffer Alarm Table -- --This table contains all Events and all the major/minor alarms --The buffer is cyclic and contains the most recent alarms. --Since this table contains also the alarms occurence time, --(appearance/disappearance for major/minor alarms), an alarm may --appear several times in this table, with alternate state: major, --off, major, etc.. sysBufferAlrTable OBJECT-TYPE SYNTAX SEQUENCE OF SysBufferAlrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of current existing alarms (of all levels)." ::= { sysBufferAlr 1 } sysBufferAlrEntry OBJECT-TYPE SYNTAX SysBufferAlrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { sysBufferAlrIdx} ::= { sysBufferAlrTable 1} SysBufferAlrEntry ::= SEQUENCE { sysBufferAlrIdx Integer32, sysBufferAlrCode Integer32, sysBufferAlrState INTEGER, sysBufferAlrSlot INTEGER, sysBufferAlrPort Integer32, sysBufferAlrDate DisplayString, sysBufferAlrTime DisplayString } sysBufferAlrIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "An index number of the current alarms." ::= { sysBufferAlrEntry 1 } sysBufferAlrCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a code related to a specific alarm description. The list of codes and thir related descriptions will be known by the NMS (for display purpose) and will appear in the unit's user manual." ::= { sysBufferAlrEntry 2 } sysBufferAlrState OBJECT-TYPE SYNTAX INTEGER { off (2), event (3), minor (4), major (5), warning (6), critical (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the alarm type. minor/major/warning/critical - indicates appearance of the problem and the type. event - indicates occurence of an event. off - indicates disappearance of an alarm. " ::= { sysBufferAlrEntry 3 } sysBufferAlrSlot OBJECT-TYPE SYNTAX INTEGER { psA (1), psB (2), clA (3), clB (4), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), io13 (17), io14 (18), io15 (19), kmxPsA (101), kmxPsB (102), kmxMlA (103), kmxMlB (104), kmxCl (105), kmxOpt (106), kmxIO1 (107), kmxIO2 (108), kmxIO3 (109), kmxIO4 (110), kmxIO5 (111), kmxIO6 (112), kmxIO7 (113), kmxIO8 (114), kmxIO9 (115), kmxIO10(116), kmxIO11(117), kmxIO12(118), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "The slot number this alarm refers to. When the alarm refers to a system function OR the DACS agent is a stand-alone unit, the value will be 'notApplicable(255)'." ::= { sysBufferAlrEntry 4 } sysBufferAlrPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The port number this alarm refers to. If the port number is irrelevant to this alarm (if it is a system/card level alarm) the value will be 9999." ::= { sysBufferAlrEntry 5 } sysBufferAlrDate OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The date when the alarm occured. The format will be according to sysSDateFormat." ::= { sysBufferAlrEntry 6 } sysBufferAlrTime OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The time when the alarm occured." ::= { sysBufferAlrEntry 7 } sysBufferAlrClearCmd OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to ON, will enforce a clear operation on the Alarms Buffer. Upon completion, the value will automatically change to off(2)." ::= { sysBufferAlr 2 } --System Configuration Parameters sysCClkSrcTable OBJECT-TYPE SYNTAX SEQUENCE OF SysCClkSrcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "All the entries of this table are identical (have the same value) for all the configurations (1..255) except the TmpCnfg. The write operation into the Table Objects is valid only for the TmpCnfg entry." ::= { sysConfig 1} sysCClkSrcEntry OBJECT-TYPE SYNTAX SysCClkSrcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {sysCClkCnfgIdx, sysCClkSrcIdx} ::= { sysCClkSrcTable 1} SysCClkSrcEntry ::= SEQUENCE { sysCClkCnfgIdx Integer32, sysCClkSrcIdx INTEGER, sysCClkSrcMode INTEGER, sysCClkSrcPrt Integer32, sysCClkStationFreq INTEGER, sysCClkRevertiveTimeout Integer32, sysCClkStationIf INTEGER } sysCClkCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg(1..255) being accessed ; Idx of 255 relates to the TmpCnfg." ::= { sysCClkSrcEntry 1} -- In phase I of DXC and FCD, only the values 1 (Cnfg1) and 255 -- (temp) are valid. sysCClkSrcIdx OBJECT-TYPE SYNTAX INTEGER { master (1), fallback (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "An index in the table. There are only two entries in the table. master - refers Master clock parameters fallback - refers Fallback clock parameters" ::= { sysCClkSrcEntry 2} sysCClkSrcMode OBJECT-TYPE SYNTAX INTEGER { none (1), internal (2), rxClk (3), station (4), lbt (5), ntr (6), adaptive (7), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This entry indicates the source the nodal timing is locked to. none - is an invalid option for Master clock. internal - is an invalid option for Fallback clock . station - is an invalid option for a stand-alone unit. lbt - loop-back timing ntr - A system locked reference clock adaptive - clcok locking is achieved by altering the clock according to the data load notApplicable - for ML source of Kmux or ML Timing combinations when Master/Fallback clock are not applicable." ::= { sysCClkSrcEntry 3} sysCClkSrcPrt OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This entry is valid only when working in rxClk mode. For ACE2002 in case of invalid entry the return value will be 0. For other products in case of invalid entry the return value will be 9999. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside, SP. * The SP ports will be numbered as follows: - SP port 1 : 1 - SP port 2 : 2 For external ports the convention used will be (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . For internal ports the convention used will be (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . For Kmux, the port will be according to : Slot*100+Ch. For ACE2002 and LA140, the port will be ifIndex." ::= { sysCClkSrcEntry 4} sysCClkStationFreq OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), f1544Khz (2), f2048Khz (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This entry indicates the frequency of the station clock when the source is 'station'. The value will be applicable only when the sysCClkSrcMode is 'station'. " ::= { sysCClkSrcEntry 5} sysCClkRevertiveTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The time in seconds in which the system will monitor the higher level clock source, before decision to revert to that clock. In case the time is zero, revertive mode will be disabled." ::= { sysCClkSrcEntry 6} sysCClkStationIf OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), g703 (2), rs422 (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This entry indicates the electrical interface connected to the station clock, when the source is 'station'. The value will be applicable only when the sysCClkSrcMode is 'station'. " ::= { sysCClkSrcEntry 7} sysCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF SysCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "All the entries of this table are identical (have the same value) for all the configurations (1..255) except the TmpCnfg. The write operation into the Table Objects is valid only for the TmpCnfg entry." ::= { sysConfig 2} sysCnfgEntry OBJECT-TYPE SYNTAX SysCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {sysCnfgIdx} ::= { sysCnfgTable 1} SysCnfgEntry ::= SEQUENCE { sysCnfgIdx Integer32, sysCMatrixMode INTEGER, sysCIsdnFormat INTEGER, sysCRoutingOnEth INTEGER, sysCAutoConfigEnable INTEGER, sysCIntTsAllocMode INTEGER } sysCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg(1..255) being accessed ; Idx of 255 relates to the TmpCnfg." ::= { sysCnfgEntry 1} sysCMatrixMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), bidirectional (2), unidirectional (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the TS Matrix Mode: bidirectional - TS Assignment Matrix is symmetric. unidirectional - TS Assignment Matrix can be asymmetric. notApplicable - for agents that do not support this feature." ::= { sysCnfgEntry 2} sysCIsdnFormat OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), te (2), nt (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "ISDN format. This parameter controls the operation mode of the ISDN ports. te - ISDN timing is derived from the signal received from the equipment it is connected to. nt - timing of the transmit path is locked to the nodal timing source. notApplicable - for agents that do not support this feature." ::= { sysCnfgEntry 3} sysCRoutingOnEth OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), none (2), proprietary (3), rip2 (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Mng Routing Protocol on the online CL Ethernet port." ::= { sysCnfgEntry 4} sysCAutoConfigEnable OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object enables user to enable/disable activating the Auto Configuration. When Auto Configuration is activated, the device learns its configuration Automatically from the Net it is connected to." ::= { sysCnfgEntry 5} sysCIntTsAllocMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), static (2), dynamic (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object enables user to select the mode of Internal TS Allocation. static - user has to select for each Dynamic card port, the Maximum TSs expected to be connected (including future growth). This number will be allocated to the ports, so that if number of connected TSs will grow within the limits of this Maximum TS limit, no disruption of data flow will occur for other ports. dynamic- TS allocation is done dynamically according to the connected TSs. No future reservations are done. This mode may cause data disruption on other ports/slots if user will want to change the number of connected TSs for a Dynamic card port. Default=static(2). " ::= { sysCnfgEntry 6} --System I/O Redundacy Table -- --This table contains all I/O cards/ports that have redundancy, --data about the redundant card/port and parameters regarding the --redundancy operation. --The table indexes are Cnfg and the Primary card&port sysCRdnTable OBJECT-TYPE SYNTAX SEQUENCE OF SysCRdnEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Configuration of all Redundant I/O cards and ports. The write operation into the table objects is valid only for the TmpCnfg. A Slot/Port that have no Redundancy, will not exist in this table." ::= { sysConfig 3 } sysCRdnEntry OBJECT-TYPE SYNTAX SysCRdnEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { sysCRdnCnfgIdx, sysCRdnPrimeSlot, sysCRdnPrimePort} ::= { sysCRdnTable 1} SysCRdnEntry ::= SEQUENCE { sysCRdnCnfgIdx Integer32, sysCRdnPrimeSlot INTEGER, sysCRdnPrimePort Integer32, sysCRdnSecSlot INTEGER, sysCRdnSecPort Integer32, sysCRdnMode INTEGER, sysCRdnRecMode INTEGER, sysCRdnRecTime Integer32, sysCRdnHwSwFlip INTEGER, sysCRdnRowStatus RowStatus, sysCRdnOnline INTEGER, sysCRdnSwitchingMode INTEGER, sysCRdnFlipUponEvent Integer32, sysCRdnLosOrLofTime Integer32, sysCRdnEventsTimeWindow Integer32, sysCRdnSequenceNumberThreshold Integer32, sysCRdnBufferErrorsThreshold Integer32, sysCRdnBuffUnderrunTime Integer32 } sysCRdnCnfgIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Idx of the Cnfg(1..255) being accessed ; Idx of 255 relates to the TmpCnfg." ::= { sysCRdnEntry 1 } sysCRdnPrimeSlot OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), io13 (17), io14 (18), io15 (19), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "The slot number of the Primary card of Redundancy. The Primary card should be the card that user wishes to be the online card (usually the more important one). For some Redundancy modes the importance of the redundant cards/ports is the same. " ::= { sysCRdnEntry 2 } sysCRdnPrimePort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The port number. For DXC: For external ports the convention used will be: - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . For internal ports the convention used will be: - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . For MP: For external ports, the value will be as that of the port in the card. Example: external-3 -> 3 external-4 -> 4 For internal ports, the value will be 100 + the port in the card. Example: internal-1 -> 101 internal-4 -> 104 For IP Bundles, the value will be the Bundle ifIndex. For other products - refer to product specification. 100=notApplicable (when Redundancy is at card level)." ::= { sysCRdnEntry 3 } sysCRdnSecSlot OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), io13 (17), io14 (18), io15 (19), notApplicable (255) } MAX-ACCESS read-create STATUS current DESCRIPTION "The slot number of the Secondary card of Redundancy matching the Primary slot." ::= { sysCRdnEntry 4 } sysCRdnSecPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The port number. For DXC: For external ports the convention used will be: - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . For internal ports the convention used will be: - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . For MP: For external ports, the value will be as that of the port in the card. Example: external-3 -> 3 external-4 -> 4 For internal ports, the value will be 100 + the port in the card. Example: internal-1 -> 101 internal-4 -> 104 For IP Bundles, the value will be the Bundle ifIndex. For other products - refer to product specification. 100=notApplicable (when Redundancy is at card level)." ::= { sysCRdnEntry 5 } sysCRdnMode OBJECT-TYPE SYNTAX INTEGER { dualCableAIS (2), yCable (3), dualCableParallelTx (4), backup (5), singleSlotProtection(6), onePlusOne (7), oneToOne (8) } MAX-ACCESS read-create STATUS current DESCRIPTION "Redundancy Mode. DXC supports: yCable(3), singleSlotProtection(6) and dualCableParallelTx(4) MP supports: dualCableAIS(2), yCable(3), dualCableParallelTx(4) and backup(5). backup - will be used when a port is backup of more than one port. IPmux: onePlusOne(7) and oneToOne(8) use for Bundle redundancy." ::= { sysCRdnEntry 6 } sysCRdnRecMode OBJECT-TYPE SYNTAX INTEGER { auto (2), manual (3) } MAX-ACCESS read-create STATUS current DESCRIPTION "Recovery Mode. This object determines if after recovery of the failed card/port it will become on-line again or not: auto - automatic . In this case, the failed card/port will become on-line again after recovery, automatically. manual - In this case, the failed card/port will not become on-line again after recovery." ::= { sysCRdnEntry 7 } sysCRdnRecTime OBJECT-TYPE SYNTAX Integer32 (1..99) MAX-ACCESS read-create STATUS current DESCRIPTION "Redundancy Recovery Time (sec). After switching to the current online card, the next switch can be performed only after a minimum time, indicated by this object. This object is applicable only when sysCRdnRecMode=auto." ::= { sysCRdnEntry 8 } sysCRdnHwSwFlip OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), hw (2), sw (3) } MAX-ACCESS read-create STATUS current DESCRIPTION "HW or SW decision for Redundancy Flip. This object is applicable only for sysCRdnMode=singleSlotProtection. HW - decision is by I/O card SW - decision is by CL SW." ::= { sysCRdnEntry 9 } sysCRdnRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This parameter allows NMS to create/delete entries of this table. The only possible supported RowStatus vaules are active (1) and destroy (6)." ::= { sysCRdnEntry 10 } sysCRdnOnline OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), primary (2), secondary (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Status - who is the Online (current) Redundancy Slot/Port. This object shows only the Online Slot/Port regarding the Redundancy. mdlSActivity or prtGenActiveStatus of the same Slot/Port may be Offline." ::= { sysCRdnEntry 11 } sysCRdnSwitchingMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), biDirectional (2), --1+1 uniDirectional (3) --1:1 } MAX-ACCESS read-create STATUS current DESCRIPTION "This object defines which Self Healing Ring (SHR) SDH ring is used: Uni Directional or BiDirectional. The type of the ring is defined according to the direction of traffic flow under normal working conditions. In Bi Directional ring, the duplex traffic is on the same path and transverses the same set of nodes for both directions of transmission. In Uni Directional ring, the duplex traffic travels over opposite path (per direction) and all the node of the ring are involved. For Uni Directional SHR Protection Switching (Single Ended Switching) is controlled by one node of the SDH ring, and does not require a protocol. For Bi Directional SHR Protection Switching (Dual Ended switching) is controlled by some nodes of the ring and requires a protocol" ::= { sysCRdnEntry 12 } sysCRdnFlipUponEvent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object allows user to define if Flip to the other port will be performed (or not), for certain possible events. Each event is represented by a bit. The value of the object is a sum of 2**n, according to the bits having '1' value. '1' - means that Flip should occur due to this event. Bit 0 (LSB) = SD (Signal Degraded). For IPmux: Bit 0 (LSB) = TDM Line LOS/LOF. Bit 1 = Sequence Number. Bit 2 = Jitter Buffer errors." ::= { sysCRdnEntry 13 } sysCRdnLosOrLofTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "This parameter determines how much time to wait before switching, after LOF or LOS are detected on the TDM Line. For Ipmux time is counted in msec." ::= { sysCRdnEntry 14 } sysCRdnEventsTimeWindow OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "This parameter determines the time window in which to count events to trigger protection switching. For Ipmux time is counted in seconds." ::= { sysCRdnEntry 15 } sysCRdnSequenceNumberThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "This parameter determines the number of Sequence Number errors that should occur in the time window in order to cause switching." ::= { sysCRdnEntry 16 } sysCRdnBufferErrorsThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "This parameter determines the number of Buffer undeflow/ overflow events occured in the time window that cause switching." ::= { sysCRdnEntry 17 } sysCRdnBuffUnderrunTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "This parameter determines how much time to wait before switching, after jitter buffer underrun. Switching occurs if no frame arrives within that time. For Ipmux time is counted in msec." ::= { sysCRdnEntry 18 } --System Database operations sysDbaseSanityCheckCmd OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to on(3) will initiate the process of Sanity check on the TmpCnfg. Upon completion, the value will automatically change to off(2)." ::= { sysDbase 1 } sysDbaseDownloadCnfgIdxCmd OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute specifies the Id of the target RealCnfg to which the TmpCnfg should be transferred. Upon set command, the DACS agent will initiate the Sanity-Check process. If successful, the actual transfer will be performed. If there will be errors, the user will have to perform the command again after errors correction. The operation is valid only on configuration numbers that do not exceed sysSMaxNoOfCnfg." ::= { sysDbase 2 } -- In phase I of DXC and FCD only the value 1 (Cnfg1) is valid. sysDbaseUploadCnfgIdxCmd OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute specifies the Id of the source Cnfg to be loaded into the TmpCnfg. Upon set operation the actual transfer will be initiated. The operation is valid only on configuration numbers that do not exceed sysSMaxNoOfCnfg." ::= { sysDbase 3 } -- In phase I of DXC and FCD only the value 1 (Cnfg1) is valid. sysDbaseFlipTable OBJECT-TYPE SYNTAX SEQUENCE OF SysDbaseFlipEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Dbase Flip time and activation for every configuration." ::= { sysDbase 4 } sysDbaseFlipEntry OBJECT-TYPE SYNTAX SysDbaseFlipEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {sysDbaseFlipIdx} ::= { sysDbaseFlipTable 1} SysDbaseFlipEntry ::= SEQUENCE { sysDbaseFlipIdx Integer32, sysDbaseFlipTime DisplayString, sysDbaseFlipActivation INTEGER } sysDbaseFlipIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg being the target Configuration." ::= { sysDbaseFlipEntry 1} sysDbaseFlipTime OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the time (HH:MM) when this data base will start being used by the Tmp config." ::= { sysDbaseFlipEntry 2} sysDbaseFlipActivation OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates if the Dbase flip will be activated at the time specified for this configuration (enable) or not (disable). No more than one flip should be enabled for the same time." ::= { sysDbaseFlipEntry 3} --Module (card) level of DACS MIB mdlGen OBJECT IDENTIFIER ::= {mdlDacsMux 1} mdlCl OBJECT IDENTIFIER ::= {mdlDacsMux 2} mdlPs OBJECT IDENTIFIER ::= {mdlDacsMux 3} --DACS module (card) general parameters (common to all cards --type) --General Card - Status information table --This table is NOT-APPLICABLE for a stand-alone unit mdlSTable OBJECT-TYPE SYNTAX SEQUENCE OF MdlSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= { mdlGen 1 } mdlSEntry OBJECT-TYPE SYNTAX MdlSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { mdlSSltIdx } ::= { mdlSTable 1} MdlSEntry ::= SEQUENCE { mdlSSltIdx INTEGER, mdlSCardType INTEGER, mdlSHwVer DisplayString (SIZE (0..255)), mdlSSwVer DisplayString (SIZE (0..255)), mdlSAlarmStatus INTEGER, mdlSAlarmStatusAll INTEGER, mdlSTestStatus INTEGER, mdlSHwStatus INTEGER, mdlSActivity INTEGER, mdlSAlrClearCmd INTEGER, mdlSAlrClearAllCmd INTEGER, mdlSAlrMaskAll INTEGER, mdlSCmd Integer32, mdlSReset INTEGER, mdlSRebuildFrame INTEGER } mdlSSltIdx OBJECT-TYPE SYNTAX INTEGER { psA (1), psB (2), clA (3), clB (4), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), io13 (17), io14 (18), io15 (19), kmxPsA (101), kmxPsB (102), kmxMlA (103), kmxMlB (104), kmxCl (105), kmxOpt (106), kmxIO1 (107), kmxIO2 (108), kmxIO3 (109), kmxIO4 (110), kmxIO5 (111), kmxIO6 (112), kmxIO7 (113), kmxIO8 (114), kmxIO9 (115), kmxIO10(116), kmxIO11(117), kmxIO12(118) } MAX-ACCESS read-only STATUS current DESCRIPTION "A unique number to identify a slot position in the DACS. The Kilomux should use enumerated values starting with kmx." ::= { mdlSEntry 1} mdlSCardType OBJECT-TYPE SYNTAX INTEGER { -- -- General types -- unknown (1), empty (2), -- Power Supply Modules -- psAC (10), psDC (11), -- -- Cl Modules -- dCl (20), kCl (21), dcl2 (22), dcl2Eth (23), kClEth (24), dcl3 (25), dcl3Eth (26), -- -- T1/E1 Modules -- d4T1 (28), d8T1 (29), dT1DSU (30), dT1CSU (31), dE1DSU (32), dE1LTU (33), dE1aDSU (34), dE1aLTU (35), dT1F (36), dE1F (37), d4E1 (38), d8E1 (39), -- -- xDSL Modules dE1Hdsl (40), --Double Slot dT1Hdsl (41), --Double Slot dE1HdslS (42), --Single Slot dT1HdslS (43), --Single Slot d16gsdsl (44), --Single Slot, for DXC3000 only d8sl (45), --Single Slot -- KMUX Main Links -- kML1 (50), kML2 (51), kML3 (52), kML4 (53), kML5 (54), kML6 (55), kML7 (56), kML8 (57), kML10 (59), kMLF (60), kML10New (61), kML11RJ45 (62), kML11FO (63), --LS Modules -- kLS1 (70), kLS1New (71), kLS2 (72), --LAN Modules -- kTRE (80), kMBE (81), kMBENew (82), fLAN (83), -- FCD STM LAN card --Optional Modules -- kai (90), kdi (91), kdiCH (92), -- HS Modules -- dHS2 (100), d8U (101), d16U (102), kHS1 (110), kHS2 (111), kHSU1 (112), kHSU2 (113), kHS703 (114), -- Voice Modules -- kVC1EM (130), kVC1FXO (131), kVC1FXS (132), kVC1MEM (133), kVC1MFXO (134), kVC1MFXS (135), kVC1MFXSW (136), kVC2EM (137), kVC2FXO (138), kVC2FXS (139), kVC2s1EM (140), --KVC2/1/E&M kVC2s1FXO (141), --KVC2/1/FXO kVC2s1FXS (142), --KVC2/1/FXS kVC3EM (143), kVC3FXO (144), kVC3FXS (145), kVC3S0 (146), -- Fax Modules -- kVF1EM (170), kVF1FXO (171), kVF1FXS (172), kVF3EM (173), kVF3FXO (174), kVF3FXS (175), kVF4EM (176), kVF4FXO (177), kVF4FXS (178), kVF4FXSW (179), kVF4S0 (180), kVF5PbxE1 (181), kVF5E1PbxSlave (182), kVF5PbxT1 (183), kVF5T1PbxSlave (184), kVF5PbxE1New (185), kVF5E1PbxSlaveNew (186), kVF5PbxT1New (187), kVF5T1PbxSlaveNew (188), kVF4FXO3 (189), kVF4FXS3 (190), kVF4NS0 (191), kVF6E1s16 (192), --KVF.6/E1/16 kVF6E1s31 (193), --KVF.6/E1/31 kVF6T1s12 (194), --KVF.6/T1/12 kVF6T1s24 (195), --KVF.6/T1/24 kVF8EM (196), kVF8FXO (197), kVF8FXS (198), -- DIM Modules -- dimV35 (201), dimRS422 (202), dimRS530 (203), dimHssi (204), dimX21 (205), dim10BaseT (206), dimE1 (207), dim100 (208), --DACS T3/E3 Modules -- dt3G747 (209), dt3 (210), dt3f (211), de3 (212), de3f (213), -- STM-1 Modules -- dstm1s1 (214), --DSTM1/1 Fractional dstm1s2 (215), --DSTM1/2 Fractional + Redundancy fSTM1 (216), -- FCD STM STM1 card dstm1 (217), --DSTM1 Full dstm1R (218), --DSTM1 Full + Redundancy f2stm1 (219), -- FCD STM 2 STM1 ports card -- LA Modules -- laSUB (230), -- La-240 laVEM (231), -- LA-140 & La-240 laVFXO (232), -- LA-140 & La-240 laVFXS (233), -- LA-140 & La-240 laV11 (234), -- LA-140 & La-240 laV24 (235), -- LA-140 & La-240 laV35 (236), -- LA-140 & La-240 laT1 (237), -- LA-140 laT1Vxx (238), -- LA-140 laE1 (239), -- LA-140 laE1Vxx (240), -- LA-140 laISDN (241), -- LA-140 & La-240i laVxx (242), -- LA-140 laEth (243), -- LA-140 laISDNwBU (244), -- LA-140 with backup (lifeline bottom connector) laIsdnNT (245), -- LA-140 ISDN NT laIsdnNTwBU (246), -- LA-140 ISDN NT with backup (lifeline bottom connector) laIsdnTE (247), -- LA-140 ISDN TE laFXSwBU (248), -- LA-140 FXS with backup (lifeline bottom connector) laFXSs (249), -- LA-140 bottom row FXS laFXSwBUs (250), -- LA-140 bottom row FXS with backup (lifeline Top port) laIsdnNTs (251), -- LA-140 bottom row ISDN NT laIsdnNTwBUs (252), -- LA-140 bottom row ISDN NT with backup (lifeline Top port) laIsdnTEs (253), -- LA-140 bottom row ISDN TE laDp (254), -- LA-140 bottom single data port X21/V35/RS50 laSdsl (255), -- LA-140 top SDSL port laSdslDp (256), -- LA-140 top SDSL port with bottom X21 or V35 Data Port laAdslA (257), -- LA-140 bottom ADSLA port laAdslADp (258), -- LA-140 bottom ADSLA port with top X21 or V35 Data Port laAdslB (259), -- LA-140 bottom ADSLB port laAdslBDp (260), -- LA-140 bottom ADSLB port with top X21 or V35 Data Port laShdsl (261), -- LA-140 bottom SHDSL port laShdslDp (262), -- LA-140 bottom SHDSL port with top X21 or V35 Data Port laT1b (263), -- LA-140 bottom T1 port laT1bDp (264), -- LA-140 bottom T1 port with top data port laIsdnTEwBU (265), -- LA-140 ISDN TE with backup laIsdnTEwBUs (266) -- LA-140 bottom row ISDN TE with backup } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the type of the card installed in the specific slot position. Only PS's are possible in the PS slots. Only CL's are possible in the CL slots. Only IO modules are possible in the IO slots. Kmux card type start with the letter k. LA card type start with the letters la." ::= { mdlSEntry 2} mdlSHwVer OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Hardware version of the card installed in the specific slot position." ::= { mdlSEntry 3 } mdlSSwVer OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Software version of the card installed in the specific slot position." ::= {mdlSEntry 4} mdlSAlarmStatus OBJECT-TYPE SYNTAX INTEGER { off (2), major (3), minor (4), event (5), warning (6), critical (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current alarm state only for card level. This object will be set to: - critical(7): when there is at least one active (ON) critical alarm . - major (3): when there is no active critical alarm, but there is at least one active (ON) major alarm . - minor (4): when there is no active major or critical alarm, but there is at least one active minor alarm. - warning (6): when there is no active major, critical or minor alarm, but there is at least one active warning alarm. - event (5): when there is no active alarm of another type, but there is at least one active event alarm. - off(2): when there is no active (ON) alarm (since last clear operation)." ::= { mdlSEntry 5 } mdlSAlarmStatusAll OBJECT-TYPE SYNTAX INTEGER { off (2), major (3), minor (4), event (5), warning (6), critical (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current card alarm state including the lower level: card, port. This object will be set to: - critical(7): when there is at least one active (ON) critical alarm . - major (3): when there is no active critical alarm, but there is at least one active (ON) major alarm . - minor (4): when there is no active major or critical alarm, but there is at least one active minor alarm. - warning (6): when there is no active major, critical or minor alarm, but there is at least one active warning alarm. - event (5): when there is no active alarm of another type, but there is at least one active event alarm. - off(2): when there is no active (ON) alarm (since last clear operation)." ::= { mdlSEntry 6 } mdlSTestStatus OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute will be on(3) when there is at least one test running on a port of the module; otherwise the value will be off(2)." ::= { mdlSEntry 7 } mdlSHwStatus OBJECT-TYPE SYNTAX INTEGER { fail(2), ok (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute will be fail(2) when a HW FAIL exists on this module (discovered by periodic self test); otherwise the value will be ok(3)." ::= { mdlSEntry 8 } mdlSActivity OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), offline (2), online (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "notApplicable - when the slot is empty (no module) offline(1) - when the module is not active (redundant) online (2) - when the module is active ." ::= { mdlSEntry 9 } mdlSAlrClearCmd OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to ON, will enforce a clear operation on the card level alarms . Upon completion, the value will automatically change to off(2)." ::= { mdlSEntry 10 } mdlSAlrClearAllCmd OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to ON, will enforce a clear operation on card and port level alarms . Upon completion, the value will automatically change to off(2)." ::= { mdlSEntry 11 } mdlSAlrMaskAll OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "on(3) - will cause masking of all the card level alarms. These alarms will not be sent to NMS and will not be taken into account for Alarms Status. off(2) - will unmask all card level alarms except those masked via the mdlAlrMaskTable. " ::= { mdlSEntry 12 } mdlSCmd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "General object for any special command at card level. 0=NotApplicable, for cards that don't support this object. For KML.10(ISDN) card of KM-2100, the object will indicate Manual Call Command in Switch mode. It is applicable only when for KML.10, prtIsdnSwitchMode=manual. KML.10 valid values: '1' = noOp, will be used by agents that do not support this feature or object (old KM agents) '2' = off, Set call command mode to disconnect state. Disconnects the call. '3' = on, Set call command mode to connect state. Connects the call. For DXC IO cards, the object will be used for IO Card Reset HW command: '2' = off, this will be always the Get value for these cards. '3' = on, this is the Set command used to Reset the IO card. Upon completing the operation, the value will automatically change to off(2), by Agent. For Slots that are NOT IO Slots and for empty IO Slots, the Get value will be always '0' (NotApplicable). " ::= { mdlSEntry 13 } mdlSReset OBJECT-TYPE SYNTAX INTEGER { off (2), on (3) --HW } MAX-ACCESS read-write STATUS current DESCRIPTION "Reset action to be performed on the module." ::= { mdlSEntry 14 } mdlSRebuildFrame OBJECT-TYPE SYNTAX INTEGER {notApplicable(1), off (2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable only for KiloMux Main Link cards only. '2' = off, this will be always the Get value. '3' = on, this is the Set command used to Rebuild the Frame. Upon completing the operation, the value will automatically change to off(2), by Agent." ::= { mdlSEntry 15} --General Card - Configuration table --This table is NOT-APPLICABLE for a stand-alone unit mdlCTable OBJECT-TYPE SYNTAX SEQUENCE OF MdlCEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= { mdlGen 2 } mdlCEntry OBJECT-TYPE SYNTAX MdlCEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { mdlCConfigIdx, mdlCSlotIdx } ::= { mdlCTable 1} MdlCEntry ::= SEQUENCE { mdlCConfigIdx Integer32, mdlCSlotIdx INTEGER, mdlCProgCardType INTEGER, mdlCNoOfExtPrt Integer32, -- RO mdlCNoOfIntPrt Integer32, -- RO mdlCParam Integer32 } mdlCConfigIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Configuration number (1..255) referred. Value of 255 specifies the TmpCnfg (Scratch)." ::= { mdlCEntry 1} -- In phase 1 only the values 1 (Cnfg1) and 255 (temp) are valid. mdlCSlotIdx OBJECT-TYPE SYNTAX INTEGER { psA (1), psB (2), clA (3), clB (4), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), io13 (17), io14 (18), io15 (19), kmxPsA (101), kmxPsB (102), kmxMlA (103), kmxMlB (104), kmxCl (105), kmxOpt (106), kmxIO1 (107), kmxIO2 (108), kmxIO3 (109), kmxIO4 (110), kmxIO5 (111), kmxIO6 (112), kmxIO7 (113), kmxIO8 (114), kmxIO9 (115), kmxIO10(116), kmxIO11(117), kmxIO12(118) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a unique number of the slot position in which the module is inserted. The Kilomux should use enumerated values starting with kmx." ::= { mdlCEntry 2} mdlCProgCardType OBJECT-TYPE SYNTAX INTEGER { -- -- General types -- unknown (1), empty (2), -- Power Supply Modules -- psAC (10), psDC (11), -- -- Cl Modules -- dCl (20), kCl (21), dcl2 (22), dcl2Eth (23), kClEth (24), dcl3 (25), dcl3Eth (26), -- -- T1/E1 Modules -- d4T1 (28), d8T1 (29), dT1DSU (30), dT1CSU (31), dE1DSU (32), dE1LTU (33), dE1aDSU (34), dE1aLTU (35), dT1F (36), dE1F (37), d4E1 (38), d8E1 (39), -- -- xDSL Modules dE1Hdsl (40), --Double Slot dT1Hdsl (41), --Double Slot dE1HdslS (42), --Single Slot dT1HdslS (43), --Single Slot d16gsdsl (44), --Single Slot, for DXC3000 only d8sl (45), --Single Slot -- KMUX Main Links -- kML1 (50), kML2 (51), kML3 (52), kML4 (53), kML5 (54), kML6 (55), kML7 (56), kML8 (57), kML10 (59), kMLF (60), kML10New (61), kML11RJ45 (62), kML11FO (63), --LS Modules -- kLS1 (70), kLS1New (71), kLS2 (72), --LAN Modules -- kTRE (80), kMBE (81), kMBENew (82), fLAN (83), -- FCD STM LAN moudle --Optional Modules -- kai (90), kdi (91), kdiCH (92), -- HS Modules -- dHS2 (100), d8U (101), d16U (102), kHS1 (110), kHS2 (111), kHSU1 (112), kHSU2 (113), kHS703 (114), -- Voice Modules -- kVC1EM (130), kVC1FXO (131), kVC1FXS (132), kVC1MEM (133), kVC1MFXO (134), kVC1MFXS (135), kVC1MFXSW (136), kVC2EM (137), kVC2FXO (138), kVC2FXS (139), kVC2s1EM (140), --KVC2/1/E&M kVC2s1FXO (141), --KVC2/1/FXO kVC2s1FXS (142), --KVC2/1/FXS kVC3EM (143), kVC3FXO (144), kVC3FXS (145), kVC3S0 (146), -- Fax Modules -- kVF1EM (170), kVF1FXO (171), kVF1FXS (172), kVF3EM (173), kVF3FXO (174), kVF3FXS (175), kVF4EM (176), kVF4FXO (177), kVF4FXS (178), kVF4FXSW (179), kVF4S0 (180), kVF5PbxE1 (181), kVF5E1PbxSlave (182), kVF5PbxT1 (183), kVF5T1PbxSlave (184), kVF5PbxE1New (185), kVF5E1PbxSlaveNew (186), kVF5PbxT1New (187), kVF5T1PbxSlaveNew (188), kVF4FXO3 (189), kVF4FXS3 (190), kVF4NS0 (191), kVF6E1s16 (192), --KVF.6/E1/16 kVF6E1s31 (193), --KVF.6/E1/31 kVF6T1s12 (194), --KVF.6/T1/12 kVF6T1s24 (195), --KVF.6/T1/24 kVF8EM (196), kVF8FXO (197), kVF8FXS (198), -- DIM Modules -- dimV35 (201), dimRS422 (202), dimRS530 (203), dimHssi (204), dimX21 (205), dim10BaseT (206), dimE1 (207), dim100 (208), --DACS T3/E3 Modules -- dt3G747 (209), dt3 (210), dt3f (211), de3 (212), de3f (213), -- STM-1 Modules -- dstm1s1 (214), --DSTM1/1 Fractional dstm1s2 (215), --DSTM1/2 Fractional + Redundancy fstm1 (216), --FCD STM STM1 card dstm1 (217), --DSTM1 Full dstm1R (218), --DSTM1 Full + Redundancy f2stm1 (219) -- FCD STM 2 STM1 ports card -- The following numbers are used in mdlSCardType, for LA modules: -- -- laSUB (230) -- laVEM (231) -- laVFXO (232) -- laVFXS (233) -- laV11 (234) -- laV24 (235) -- laV35 (236) -- laT1 (237), -- laT1Vxx (238), -- laE1 (239), -- laE1Vxx (240), -- laISDN (241), -- laVxx (242), -- laEth (243), -- laISDNwBU (244), -- laIsdnNT (245), LA-140 ISDN NT -- laIsdnNTwBU (246), LA-140 ISDN NT with backup (lifeline bottom connector) -- laIsdnTE (247), LA-140 ISDN TE -- laFXSwBU (248), LA-140 FXS with backup (lifeline bottom connector) -- laFXSs (249), LA-140 bottom row FXS -- laFXSwBUs (250), LA-140 bottom row FXS with backup (lifeline Top port) -- laIsdnNTs (251), LA-140 bottom row ISDN NT -- laIsdnNTwBUs (252), LA-140 bottom row ISDN NT with backup (lifeline Top port) -- laIsdnTEs (253), LA-140 bottom row ISDN TE -- laDp (254), LA-140 bottom single data port X21/V35/RS50 -- laSdsl (255), LA-140 top SDSL port -- laSdslDp (256), LA-140 top SDSL port with bottom X21 or V35 Data Port -- laAdslA (257), LA-140 bottom ADSLA port -- laAdslADp (258), LA-140 bottom ADSLA port with top X21 or V35 Data Port -- laAdslB (259), LA-140 bottom ADSLB port -- laAdslBDp (260), LA-140 bottom ADSLB port with top X21 or V35 Data Port -- laShdsl (261), LA-140 bottom SHDSL port -- laShdslDp (262), LA-140 bottom SHDSL port with top X21 or V35 Data Port -- laT1b (263), LA-140 bottom T1 port -- laT1bDp (264), LA-140 bottom T1 port with top data port -- laIsdnTEwBU (265), LA-140 ISDN TE with backup -- laIsdnTEwBUs (266) LA-140 bottom row ISDN TE with backup } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the card type assigned to the specific slot in the common configuration. This object is identical for all the configurations (1..255). Only the TmpCnf(255) might have a different value. The write operation is valid only for the TmpCnfg entry." ::= { mdlCEntry 3} mdlCNoOfExtPrt OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of external ports in the programmed module of the specific slot position" ::= { mdlCEntry 4} mdlCNoOfIntPrt OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of internal ports in the programmed module of the specific slot position." ::= { mdlCEntry 5} mdlCParam OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "General configuration object at card level (per configuration). NotApplicable=0, for cards that don't support this object. For D8U and D16U cards of DXC, the object will indicate the port on which BERT will be performed. The port can be one of the external ports, any of its associated B1, B2, D ports or no port of the card (None=0). For port indexes see DXC R6 spec." ::= {mdlCEntry 6 } --Module level current alarms mdlAlr OBJECT IDENTIFIER ::= {mdlGen 3} mdlAlrTable OBJECT-TYPE SYNTAX SEQUENCE OF MdlAlrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The list of card alarms. " ::= { mdlAlr 1 } mdlAlrEntry OBJECT-TYPE SYNTAX MdlAlrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {mdlAlrSltIdx , mdlAlrIdx} ::= { mdlAlrTable 1} MdlAlrEntry ::= SEQUENCE { mdlAlrSltIdx INTEGER, mdlAlrIdx Integer32, mdlAlrCode Integer32, mdlAlrState INTEGER, --severity mdlAlarmMask INTEGER, mdlAlarmInvert INTEGER, mdlAlarmOnOff INTEGER, mdlAlarmCounter Integer32 } mdlAlrIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique number to identify an entry in the alarm status table. Users should use the get next function to read this table because the indexes are not consecutive" ::= { mdlAlrEntry 1} mdlAlrSltIdx OBJECT-TYPE SYNTAX INTEGER { psA (1), psB (2), clA (3), clB (4), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), io13 (17), io14 (18), io15 (19), kmxPsA (101), kmxPsB (102), kmxMlA (103), kmxMlB (104), kmxCl (105), kmxOpt (106), kmxIO1 (107), kmxIO2 (108), kmxIO3 (109), kmxIO4 (110), kmxIO5 (111), kmxIO6 (112), kmxIO7 (113), kmxIO8 (114), kmxIO9 (115), kmxIO10(116), kmxIO11(117), kmxIO12(118) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the desired slot position. The Kilomux should use enumerated values starting with kmx." ::= { mdlAlrEntry 2} mdlAlrCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a code related to a specific alarm description. The list of codes and their related descriptions will be sent to NMS request (for display purpose) by alrGenTable." ::= { mdlAlrEntry 3 } mdlAlrState OBJECT-TYPE SYNTAX INTEGER { event (3), minor (4), major (5), warning (6), critical (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the card alarm severity." ::= { mdlAlrEntry 4 } mdlAlarmMask OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm Mask is : on/off." ::= { mdlAlrEntry 5 } mdlAlarmInvert OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm Invert is : on/off." ::= { mdlAlrEntry 6 } mdlAlarmOnOff OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm state is : on/off." ::= { mdlAlrEntry 7} mdlAlarmCounter OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A counter - how many times the alarm occured (ON) since last clear operation or since last Reset." ::= { mdlAlrEntry 8 } mdlAlrMaskTable OBJECT-TYPE SYNTAX SEQUENCE OF MdlAlrMaskEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The list of card masked alarms. " ::= { mdlAlr 2 } mdlAlrMaskEntry OBJECT-TYPE SYNTAX MdlAlrMaskEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {mdlAlrMaskSltIdx} ::= { mdlAlrMaskTable 1} MdlAlrMaskEntry ::= SEQUENCE { mdlAlrMaskSltIdx INTEGER, mdlAlrMask OCTET STRING } mdlAlrMaskSltIdx OBJECT-TYPE SYNTAX INTEGER { psA (1), psB (2), clA (3), clB (4), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), io13 (17), io14 (18), io15 (19), kmxPsA (101), kmxPsB (102), kmxMlA (103), kmxMlB (104), kmxCl (105), kmxOpt (106), kmxIO1 (107), kmxIO2 (108), kmxIO3 (109), kmxIO4 (110), kmxIO5 (111), kmxIO6 (112), kmxIO7 (113), kmxIO8 (114), kmxIO9 (115), kmxIO10(116), kmxIO11(117), kmxIO12(118) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the desired slot position. The Kilomux should use enumerated values starting with kmx." ::= { mdlAlrMaskEntry 1} mdlAlrMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8..10)) MAX-ACCESS read-write STATUS current DESCRIPTION "This object is a mask that indicates which card level alarms are masked. The masked alarms (their bit is set to '1') are neither sent to the manager, nor taken into account for alarm status and LEDs. Bit no. = Alarm code The bits that do not belong to the card level will be 0. This object is applicable only when mdlSAlrMaskAll=off (otherwise all card alarms are masked). Example: When Alarm having the code 8 is masked, the value of this object will be 100 (hex)." ::= { mdlAlrMaskEntry 2 } --DACS dcl (Common Logic) card specific parameters mdlClTable OBJECT-TYPE SYNTAX SEQUENCE OF MdlClEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= { mdlCl 1 } mdlClEntry OBJECT-TYPE SYNTAX MdlClEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { mdlClIdx } ::= { mdlClTable 1} MdlClEntry ::= SEQUENCE { mdlClIdx INTEGER, mdlClSwchStatus Integer32, mdlClLastFlipDate DisplayString, mdlClLastFlipTime DisplayString, mdlClLastFlipCause DisplayString } mdlClIdx OBJECT-TYPE SYNTAX INTEGER { clA (3), clB (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Cl slot referred." ::= { mdlClEntry 1} mdlClSwchStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the status of the switches on the referred DCL card. Each switch is represented by a bit. The status is a sum of 2**n, according to the bits. There are 4 switches: bit 0 SP-PAR (LSB) '1' - Default parameters bit 1 PSWRD '1' - Password=default '0' - Password=user selected bit 2 DB-INIT '1' - DB initiated with default '0' - DB initiated with NVRAM contents bit 3 PC-SP (MSB) '1' - Management by terminal only '0' - Management by NMS Example: If SP-PAR and PSWRD bits are set ('1'), the value will be 3 (2**1 + 2**0). When the status of the switches is unknown, the value of this object will be 255." ::= { mdlClEntry 2} mdlClLastFlipDate OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Date when last flip occured. The format would be as specified by the sysSDateFormat." ::= {mdlClEntry 3} mdlClLastFlipTime OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Time when last flip occured." ::= {mdlClEntry 4} mdlClLastFlipCause OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The cause of last flip." ::= {mdlClEntry 5} --DACS Ps (Power Supply) card specific parameters mdlPsTable OBJECT-TYPE SYNTAX SEQUENCE OF MdlPsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= { mdlPs 1 } mdlPsEntry OBJECT-TYPE SYNTAX MdlPsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { mdlPsIdx } ::= { mdlPsTable 1} MdlPsEntry ::= SEQUENCE { mdlPsIdx INTEGER, mdlPsStatus INTEGER, mdlPsTestResult INTEGER } mdlPsIdx OBJECT-TYPE SYNTAX INTEGER { psA (1), psB (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the PS card referred." ::= { mdlPsEntry 1} mdlPsStatus OBJECT-TYPE SYNTAX INTEGER { notActive (1), active (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the status of the PS card." ::= { mdlPsEntry 2} mdlPsTestResult OBJECT-TYPE SYNTAX INTEGER { ok (1), f12V (2), f5V (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the result of the PS card test. ok (1) - the test passed successfully. f12V (2) - 12V FAIL was detected f5V (3) - 5V FAIL was detected." ::= { mdlPsEntry 3} --Port level of DACS MIB prtGen OBJECT IDENTIFIER ::= {prtDacsMux 1} prtT1E1 OBJECT IDENTIFIER ::= {prtDacsMux 2} prtHS OBJECT IDENTIFIER ::= {prtDacsMux 3} prtSP OBJECT IDENTIFIER ::= {prtDacsMux 4} prtDim OBJECT IDENTIFIER ::= {prtDacsMux 5} prtI OBJECT IDENTIFIER ::= {prtDacsMux 6} --ISDN port prtHdsl OBJECT IDENTIFIER ::= {prtDacsMux 7} --HDSL Line prtT3E3 OBJECT IDENTIFIER ::= {prtDacsMux 8} --T3/E3 interface --DACS port general parameters (common to all ports type except SP) --The table contains both status and configuration information prtGenParamTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtGenEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= { prtGen 1 } prtGenEntry OBJECT-TYPE SYNTAX PrtGenEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { prtGenPrtIdx } ::= { prtGenParamTable 1} PrtGenEntry ::= SEQUENCE { prtGenPrtIdx Integer32, prtGenSlt INTEGER, prtGenExtInt INTEGER, prtGenIfIndex Integer32, prtGenActiveStatus INTEGER, prtGenAlrStatus INTEGER, prtGenTestStatus INTEGER, prtGenTestMask Integer32, prtGenTestCmd Integer32, prtGenTestRunning Integer32, prtGenType INTEGER, prtGenInterfaceType DisplayString (SIZE (0..255)), prtGenAlrClearCmd INTEGER, prtGenAlrMaskAll INTEGER, prtGenParamStatus OCTET STRING, prtGenRdnStatus INTEGER, prtGenTestMaskXP OCTET STRING, prtGenTestCmdXP OCTET STRING, prtGenTestRunningXP OCTET STRING } prtGenPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside/external, inside/internal. In the Kilomux, the port index is calculated as follows: 100*Slot+Ch. The external Ch numbers are 1..10, and the internal Ch numbers are 11..20. In the DXC : - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card in odd or even numbers, as follows: * For the outside/external ports, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside/internal ports, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 ." ::= { prtGenEntry 1} prtGenSlt OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), io13 (17), io14 (18), io15 (19), kmxMlA (103), kmxMlB (104), kmxCl (105), kmxOpt (106), kmxIO1 (107), kmxIO2 (108), kmxIO3 (109), kmxIO4 (110), kmxIO5 (111), kmxIO6 (112), kmxIO7 (113), kmxIO8 (114), kmxIO9 (115), kmxIO10(116), kmxIO11(117), kmxIO12(118), standAlone (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique number to identify the slot where the card is inserted in. When the unit is stand-alone, this object is not applicable and 255 will be used. The Kilomux should use the enumerated starting with kmx." ::= { prtGenEntry 2} prtGenExtInt OBJECT-TYPE SYNTAX INTEGER { external (2), internal (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute describes the type of the designated port. Exteral port is a port with a physical connector. Internal port might be of two types, one is a composite port which collects data of a few external ports into a common bandwidth (usually routed trough DS1 link); the other type is internal ports which get only part of external port data (usually a few DS0's). In the Kilomux-2100, the internal(3) value is used for composite channels or sub-channels of an ISDN Ch." ::= { prtGenEntry 3} prtGenIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the unique interface number assigned to the port. The specific interface of this attribute is the same as the interface identified by the value of ifindex in MIB-II.If there is no interface for the specific prtIdx, the value will be '7fffffff'h." ::= { prtGenEntry 4} prtGenActiveStatus OBJECT-TYPE SYNTAX INTEGER { unknown (1), notUsed (2), offLine (3), onLine (4), offLineRedundancy (5), onLineRedundancy (6) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute describes the activity status of the port. unknown(1) indicates that the information is not supported. notUsed(2) indicates that the port is not connected according to the active config. offLine(3) indicates that the port is down (not working) due to any problem. onLine (4) indicates that the port is up (working) offLineRedundancy(5) indicates that the port is down because it is a redundant port. onLineRedundancy (6) indicates that this is a redundant port which is up and works as the active link." ::= { prtGenEntry 5} prtGenAlrStatus OBJECT-TYPE SYNTAX INTEGER { off (2), major (3), minor (4), event (5), warning (6), critical (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the alarm state at port (ch) agent level. This object will be: - critical(7): when there is at least one active (ON) critical alarm . - major (3): when there is no active critical alarm, but there is at least one active (ON) major alarm . - minor (4): when there is no active major or critical alarm, but there is at least one active minor alarm. - warning (6): when there is no active major, critical or minor alarm, but there is at least one active warning alarm. - event (5): when there is no active alarm of another type, but there is at least one active event alarm. - off(2): when there is no active (ON) alarm (since last clear operation)." ::= { prtGenEntry 6} prtGenTestStatus OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute will be on(3) when there is at least one test in progress (running) on the port; otherwise the value will be off(2)." ::= { prtGenEntry 7} prtGenTestMask OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a mask which indicates which tests from the 'prtGenTestCmd' list are allowed for the selected port. If a specific test is allowed, its respective bit will be SET in the mask : TEST BIT ----------- --- localLoop 1 remoteLoop 2 bert 3 plb 4 inband 5 prbs 8 loop2-v54 (RLB) 9 loop3-v54 (LLB) 10 Tone injection 13 Tx-plb 14 Tx-llb 15 DTE loop (HSSI) 16 HDSL-Tx-Inband 20 HDSL-Rx-Inband 21 Monitor 22 (test port) User Line Loopback 23 Rem-Loop-on-Rem-Unit 25 LBBD 26 LB1 27 LB2 28 BERT-on-Rem-Unit 29 TS Remote Loop 30 LLB-on-Rem-Unit 31 e.g : If the return value is 3 -> 0000000000000011 -> Bits 1 & 2 are set -> the allowed tests are : local-loop remote-loop " ::= { prtGenEntry 8} prtGenTestCmd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this object to a value as detailed furter on (except 0) will initiate a test on the specific port, if the operation is allowed (according to TestMask). If the operation is not allowed, the mux will ignore the operation. The test/s requested will be set according to the respective bit: TEST BIT ----------- --- localLoop 1 remoteLoop 2 bert 3 plb 4 inband 5 prbs 8 loop2-v54 (RLB) 9 loop3-v54 (LLB) 10 Tone injection 13 Tx-plb 14 Tx-llb 15 DTE loop (HSSI) 16 HDSL-Tx-Inband 20 HDSL-Rx-Inband 21 Monitor 22 (test port) User Line Loopback 23 Rem-Loop-on-Rem-Unit 25 LBBD 26 LB1 27 LB2 28 BERT-on-Rem-Unit 29 TS Remote Loop 30 LLB-on-Rem-Unit 31 e.g : If the requested value is 3 -> 0000000000000011 -> Bits 1 & 2 are set -> the requested tests are : local-loop remote-loop Setting this object to stop (value=0 ; all bits are 0), will stop all the user requested tests running on the selected port; it will NOT stop the tests initiated by the system." ::= { prtGenEntry 9} prtGenTestRunning OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates which tests are running currently on the selected port (initiated by user and/or by the system). If a specific test is currently running on the port, its respective bit will be SET: TEST BIT ----------- --- localLoop 1 remoteLoop 2 bert 3 plb 4 llb 5 txInband 6 rxInband 7 prbs 8 loop2-v54 (RLB) 9 loop3-v54 (LLB) 10 DDS DSU loop 11 DDS CSU loop 12 Tone injection 13 Tx-plb 14 Tx-llb 15 DTE loop (HSSI) 16 Local DTE loop (HSSI)17 Local Line loop (HSSI)18 Remote Line loop (HSSI)19 HDSL-Tx-Inband 20 HDSL-Rx-Inband 21 Monitor 22 (test port) User Line Loopback 23 Network Line Loopback 24 Rem-Loop-on-Rem-Unit 25 LBBD 26 LB1 27 LB2 28 BERT-on-Rem-Unit 29 TS Remote Loop 30 LLB-on-Rem-Unit 31 e.g : If the return value is 3 -> 0000000000000011 -> Bits 1 & 2 are set -> the running tests are : local-loop remote-loop llb (Bit 5) - can be initiated by system only! " ::= { prtGenEntry 10} prtGenType OBJECT-TYPE SYNTAX INTEGER { unknown (1), t1 (2), e1 (3), hs (4), t1Csu (5), t1Dsu (6), e1Ltu (7), e1Dsu (8), hdsl (9), sp (10), t1F (11), --T1 Fiber-optic e1F (12), --E1 Fiber-optic dim (13), isdn (14), t3 (15), e3 (16), t3f (17), e3f (18), idsl (19), stm1 (20), vc4 (21), vc12 (22), msdsl (23), vc11 (24), vc3 (25), soh (26), eth (27), shdsl (28), other (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object describes the type of the selected port. idsl - applicable for external ports of HS-U cards (of DXC) when interface is LT-1." ::= { prtGenEntry 11} prtGenInterfaceType OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique HW interface type of the selected port. Examples: - for T1 cards: DSU, CSU - for E1 cards: DSU, LTU - for HS cards: v35, rs422, x21 etc..." ::= { prtGenEntry 12} prtGenAlrClearCmd OBJECT-TYPE SYNTAX INTEGER { noOp (1), off (2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to ON, will enforce a clear operation on the port level alarms . Upon completion, the value will automatically change to off(2). noOp - will be used by agents that do not support this feature or object." ::= { prtGenEntry 13 } prtGenAlrMaskAll OBJECT-TYPE SYNTAX INTEGER { noOp (1), off (2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "on(3) - will mask all the alarms of the selected port off(2)- will unmask all alarms of the selected port except the ones selected by the prtAlrMaskTable. noOp - will be used by agents that do not support this feature or object." ::= { prtGenEntry 14 } prtGenParamStatus OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates Status of parameters specific to the selected port. - For a port that has no special status or is supported by prtSExHsfStatTable - 1 Octet: 00hex - For HS cards (Dxc cards) - 1 octet: Bit 7 (MSB)..Bit 2 = 0 (NA) Bit 0 and 1 indicates RTS control signal state: Bit 1: '1'=active ; '0'=notActive Bit 0 (LSB): '1'=unknown ; '0'=NA - For HS-U/1 external port (MP card, used in FCD-M) - 1 Octet: Bit 7 6 5 4 3 2 1 0 LSB |________| |__| |__| spare modem sync modem: 00 = other sync: 00 = not sync 01 = unknown 01 = sync 10 = ASMi-31/2 10 = reserved 11 = reserved 11 = reserved - For VC-6, VC-12, VC-12/6 external ports - 1 Octet : Bit 7 (MSB)..Bit 2 = 0 (NA) Bit 1: Tx Signaling '1'=On ; '0'=Off Bit 0 (LSB): Rx Signaling '1'=On ; '0'=Off - For VC-2/R2(FXS) external ports - 1 Octet : Bit - 7 6 5 4 3 2 1 0 |_| |_________| Call Call State Direction Bit 7 (MSB) and Bit 6 : Call Direction 00 - Incoming 01 - Outgoing Bit 5..Bit 0: Call State 000000 - Idle 000001 - Seized 000010 - Both-Way Conflict 000011 - Seizure Ack 000100 - Answered 000101 - Clear Backward 000110 - Clear Forward 000111 - Blocked 001000 - Fault 001001 - Fault 3 001010 - Fault 4 001011 - Fault 5 001100 - Fault 6 001101 - Fault 7 - For ML-20 external port - 3 Octets : - 1 MS Octet will represent the Real Rate used: Bit - 7 6 5 4 3 2 1 0 |___| |_______| spare Rate Valid values: 0..31, meaning 0..31x64Kbps Invalid values: 32..255. - 2 LS Octets will represent the Status of 7 Control Signals: Signal - --- CTS DSR DCD RJ TM DTR RTS Bit - 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Octet - 2 3 (LS) '---' will always have the value 00 Rest of the Signals (2 bits each) can have the following values: 00=NA ; 01=Unused ; 10=Off ; 11=On - For ML-H/E1, ML-H/1/E1, ML-H/S/E1 internal port - 1 Octet Bit - 7 6 5 4 3 2 1 0 |___________| spare Mode of Operation Mode of Operation: '1'=Central ; '0'=Remote - For KM2100, KVF.5 cards - indicates the status of A and B signaling for each internal channel. 1 Octet: Bit - 7 6 5 4 3 2 1 0 |_____| |_| |_| spare B A Bit 0 (LSB) and Bit 1 : A status Bit 2 and Bit 3 : B status 00 - Off 01 - On 11 - Unknown - For FCD-W, NETWORK and USER ports - 1 Octet Status of Control Signals: '1'=On ; '0'=Off or when not applicable Bit - 7 6 5 4 3 2 1 0 Bit 7 (MSB) - Signal Loss (applicable only for G.703 interface) Bit 6 - CONTROL (applicable only for X.21 interface) Bit 5 - INDICATION (applicable only for X.21 interface) Bit 4 - DSR (applicable only for V.35 interface) Bit 3 - RTS (applicable only for V.35 interface) Bit 2 - CTS (applicable only for V.35 interface) Bit 1 - DTR (applicable only for V.35 interface) Bit 0 - DCD (applicable only for V.35 interface) - For DXC R6 , D8U, D16U External ports - 1 Octet Bit 7 6 5 4 3 2 1 0 LSB |________| |__| |__| spare modem sync modem: 00 = other sync: 00 = not sync 01 = unknown 01 = sync 10 = ASMi-31/2 10 = reserved 11 = reserved 11 = reserved - For DXC DE1-HDSL, DT1-HDSL, D16GSDSL, D8SL External ports - 2 Octets MSB octet: far-end modem channel interface LSB octet: Sub Link existence (Y/N), far-end modem type, synchronization with far-end modem MSB octet: 0000 0000 = no interface 0000 0001 = db15 (X21) 0000 0010 = IR-IP 0000 0011 = IR-ETH-Q 0000 0100 = V35 0000 0101 = ETH-RJ45 0000 0110 = G703 0000 0111 = db25 (RS530) 0000 1000 = ETH-BNC 0000 1001 = E1(Balanced) 0000 1010 = E1(Unbalanced) Rest of the combinations: reserved LSB octet: Bit 7 6 5 4 3 2 1 0 LSB | |___________| |__| SL modem sync or Box material SL: modem: 00000 = other sync: 00 = not sync 0=not exist 00001 = unknown 01 = sync 1=exists 00010 = ASMi-31/2 10 = reserved 00011 = HCD-E1 11 = reserved Box material 00100 = HTU-E1 (for D8SL card): 00101 = HTU-2 0=metal 00110 = ASMi-52 SA/2W/Slave 1=plastic 00111 = ASMi-52 SA/2W/Master 01000 = ASMi-52/CQ card of LRS-24 01001 = ASMi-52/CD card of LRS-24 01010 = D16GSDSL card of DXC-3000 01011 = LRS-52 01100 = FCD 01110 = D8GSDSL card of DXC-3000 Rest = reserved " ::= { prtGenEntry 15} prtGenRdnStatus OBJECT-TYPE SYNTAX INTEGER { none (1), off (2), on (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates if this port is part of a redundant pair and in this case, if it is On or Off. none(1) - No redundancy or Not Applicable off (2) - the port is part of a redundant pair and it is Off from Redundancy point of view (not the port used). on (3) - the port is part of a redundant pair and it is On from Redundancy point of view (it is the port used)." ::= { prtGenEntry 16 } prtGenTestMaskXP OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This is an Expanded test mask of the prtGenTestMask object. The prtGenTestMask object reached its maximum, being an Integer with 31 bits. This object indicates which tests from the 'prtGenTestCmdXP' list are allowed for the selected port. If a specific test is allowed, its respective bit will be SET in the mask : TEST BIT ----------- --- localLoop 1 =LSB remoteLoop 2 bert 3 plb 4 inband 5 prbs 8 loop2-v54 (RLB) 9 loop3-v54 (LLB) 10 Tone injection 13 Tx-plb 14 Tx-llb 15 DTE loop (HSSI) 16 HDSL-Tx-Inband 20 HDSL-Rx-Inband 21 Monitor 22 (test port) User Line Loopback 23 Rem-Loop-on-Rem-Unit 25 LBBD 26 LB1 27 LB2 28 BERT-on-Rem-Unit 29 TS Remote Loop 30 LLB-on-Rem-Unit 31 Downstream-AIS 32 Upstream-AIS 33 Send-RDI 34 e.g : If the return value is 00000003 hex -> Bits 1 & 2 are set -> the allowed tests are : local-loop remote-loop " ::= { prtGenEntry 17} prtGenTestCmdXP OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "This is an Expanded test command of the prtGenTestCmd object. The prtGenTestCmd object reached its maximum, being an Integer with 31 bits. Setting this object to a value as detailed furter on (except 0) will initiate a test on the specific port, if the operation is allowed (according to TestMaskXP). If the operation is not allowed, the mux will ignore the operation. The test/s requested will be set according to the respective bit: TEST BIT ----------- --- localLoop 1 =LSB remoteLoop 2 bert 3 plb 4 inband 5 prbs 8 loop2-v54 (RLB) 9 loop3-v54 (LLB) 10 Tone injection 13 Tx-plb 14 Tx-llb 15 DTE loop (HSSI) 16 HDSL-Tx-Inband 20 HDSL-Rx-Inband 21 Monitor 22 (test port) User Line Loopback 23 Rem-Loop-on-Rem-Unit 25 LBBD 26 LB1 27 LB2 28 BERT-on-Rem-Unit 29 TS Remote Loop 30 LLB-on-Rem-Unit 31 Downstream-AIS 32 Upstream-AIS 33 Send-RDI 34 e.g : If the requested value is 00000003 hex -> Bits 1 & 2 are set -> the requested tests are : local-loop remote-loop Setting this object to stop (value=0 ; all bits are 0), will stop all the user requested tests running on the selected port; it will NOT stop the tests initiated by the system." ::= { prtGenEntry 18} prtGenTestRunningXP OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This is an Expanded object of the prtGenTestRunning object. The prtGenTestRunning object reached its maximum, being an Integer with 31 bits. This object indicates which tests are running currently on the selected port (initiated by user and/or by the system). If a specific test is currently running on the port, its respective bit will be SET: TEST BIT ----------- --- localLoop 1 =LSB remoteLoop 2 bert 3 plb 4 llb 5 txInband 6 rxInband 7 prbs 8 loop2-v54 (RLB) 9 loop3-v54 (LLB) 10 DDS DSU loop 11 DDS CSU loop 12 Tone injection 13 Tx-plb 14 Tx-llb 15 DTE loop (HSSI) 16 Local DTE loop (HSSI)17 Local Line loop (HSSI)18 Remote Line loop (HSSI)19 HDSL-Tx-Inband 20 HDSL-Rx-Inband 21 Monitor 22 (test port) User Line Loopback 23 Network Line Loopback 24 Rem-Loop-on-Rem-Unit 25 LBBD 26 LB1 27 LB2 28 BERT-on-Rem-Unit 29 TS Remote Loop 30 LLB-on-Rem-Unit 31 Downstream-AIS 32 Upstream-AIS 33 Send-RDI 34 e.g : If the return value is 00000003 hex -> Bits 1 & 2 are set -> the running tests are : local-loop remote-loop llb (Bit 5) - can be initiated by system only! " ::= { prtGenEntry 19} --prtGenTestDuration - Setting Duration of tests prtGenTestDurationTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtGenTestDurationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= { prtGen 2 } prtGenTestDurationEntry OBJECT-TYPE SYNTAX PrtGenTestDurationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { prtGenTestPrtIdx, prtGenTestIdx } ::= { prtGenTestDurationTable 1} PrtGenTestDurationEntry ::= SEQUENCE { prtGenTestPrtIdx Integer32, prtGenTestIdx INTEGER, prtGenTestDuration Integer32 } prtGenTestPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside/external, inside/internal. In the Kilomux, the port index is calculated as follows: 100*Slot+Ch. The external Ch numbers are 1..10, and the internal Ch numbers are 11..20. In the DXC : - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card in odd or even numbers, as follows: * For the outside/external ports, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside/internal ports, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 ." ::= { prtGenTestDurationEntry 1} prtGenTestIdx OBJECT-TYPE SYNTAX INTEGER { localLoop (1), remoteLoop (2), bert (3), plb (4), rlb (5), llb (6), toneInjection (7), txInband (8), rxInband (9), remLoopOnRemUnit (10), bertOnRemUnit (11), llbOnRemUnit (12), txPlb (14), txLlb (15), dteLoop (16), --HSSI hdslTxInband (20), hdslRxInband (21), monitor (22), userLineLoopback(23), lbbd (26), lb1 (27), lb2 (28), tsRemoteLoop (30), downstreamAis(32), upstreamAis (33), sendRdi (34) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the test, the duration refers. " ::= { prtGenTestDurationEntry 2} prtGenTestDuration OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the maximum duration of executing a test on the specific port. This entry applies to the specified test . The resolution will be a minute, and the maximum duration is limited to 30 minutes . A zero value specifies no time limitation. When the test isn't active the agent initiates this object to 2 min. when the duration is needed and to 0 if it's not required." ::= { prtGenTestDurationEntry 3} --prtGen TS (TimeSlot) Assignment Table - for all ports of IO cards prtGenTsTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtGenTsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table's Objects is valid only for the TmpCnfg entry (Scratch),exept some products which enable direct writing to the ActiveCnfg. This is written in the respective product's spec. " ::= { prtGen 3} prtGenTsEntry OBJECT-TYPE SYNTAX PrtGenTsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtGenTsCnfgIdx, prtGenTsPrtIdx, prtGenTsIdx } ::= { prtGenTsTable 1} PrtGenTsEntry ::= SEQUENCE { prtGenTsCnfgIdx Integer32, prtGenTsPrtIdx Integer32, prtGenTsIdx Integer32, prtGenTsType INTEGER, prtGenTsIConPrt Integer32, prtGenTsIConTs Integer32 } prtGenTsCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg(1..255) being accessed. Idx of 255 relates to the TmpCnfg. " ::= { prtGenTsEntry 1} prtGenTsPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside, SP. In the DXC : - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card in odd or even numbers, as follows: * For the outside/external ports, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside/internal ports, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 ." ::= { prtGenTsEntry 2} prtGenTsIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique time slot position. The valid time slots are 1..25 for T1 Card (25=Fbit) 0..31 for E1 or HS Card . In G732S-E1 lines time slot 16 is not valid for data, it is dedicated for multiframe synchronization bits and voice signaling." ::= { prtGenTsEntry 3} prtGenTsType OBJECT-TYPE SYNTAX INTEGER { unknown (1), voice (2), data (3), vcMP (4), nc (5), mng (6) } MAX-ACCESS read-write STATUS current DESCRIPTION "The type of Timeslot. If the source or destination port is an HS port,'TS Type' must be 'data'. nc - means that this TimeSlot is not connected. voice, data, vcMP - also mean that this TS is connected. mng - means that this TS is dedicated to Management (not connected to another port." ::= { prtGenTsEntry 4} prtGenTsIConPrt OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the internally (In Mux) connected port. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside, SP. * The outside ports will be the T1/E1 cards ports. The convention used will be (for DXC): - first two digits will be: (IO slot number+10) for a stand-alone unit, the IO slot will be considered 1. - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside ports will be for example, the HS cards ports. The convention used will be (for DXC): - first two digits will be: (IO slot number+10) for a stand-alone unit, the IO slot will be considered 1. - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . * noConnection - will be indicated as 10 for DXC and FCD-E1/T1. - will be indicated as 100 for FCD-E1/I and SMODs. * Split TS (same TS is Split to several ports) - 11. * notApplicable- will be indicated as 100 for LRS IMODs. All HS port's timeslots must have the same destination port." ::= {prtGenTsEntry 5} prtGenTsIConTs OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique time slot position. The valid time slots are 1..25 for T1 Card (25=Fbit) 0..31 for E1 (or HS) Card. In G732S-E1 lines time slot 16 is not valid for data, it is dedicated for multiframe synchronization bits and voice signaling. * For DXC: All HS port's timeslots must start with Timeslot no.1 " ::= {prtGenTsEntry 6} --Port current alarms table prtAlr OBJECT IDENTIFIER ::= {prtGen 4} prtSAlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtSAlarmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= { prtAlr 1 } prtSAlarmEntry OBJECT-TYPE SYNTAX PrtSAlarmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { prtSAlarmPrtIdx, prtSAlarmIdx} ::= { prtSAlarmTable 1} PrtSAlarmEntry ::= SEQUENCE { prtSAlarmPrtIdx Integer32, prtSAlarmIdx Integer32, prtSAlarmCode Integer32, prtSAlarmState INTEGER, --severity prtSAlarmMask INTEGER, prtSAlarmInvert INTEGER, prtSAlarmOnOff INTEGER, prtSAlarmCounter Integer32 } prtSAlarmIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique number to identify an entry in the alarm status table. Users should use the get next function to read this table because the indexes are not consecutive." ::= { prtSAlarmEntry 1} prtSAlarmPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside/external, inside/internal. In the Kilomux, the port index is calculated as follows: 100*Slot+Ch. The external Ch numbers are 1..10, and the internal Ch numbers are 11..20. In the DXC : - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card in odd or even numbers, as follows: * For the outside/external ports, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside/internal ports, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 ." ::= { prtSAlarmEntry 2} prtSAlarmCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a code related to a specific alarm description. The list of codes and their related descriptions will be sent to NMS request (for display purpose) by alrGenTable." ::= { prtSAlarmEntry 3 } prtSAlarmState OBJECT-TYPE SYNTAX INTEGER { event (3), minor (4), major (5), warning (6), critical (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the port alarm severity." ::= { prtSAlarmEntry 4 } prtSAlarmMask OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm Mask is : on/off." ::= { prtSAlarmEntry 5 } prtSAlarmInvert OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm Invert is : on/off." ::= { prtSAlarmEntry 6 } prtSAlarmOnOff OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm state is : on/off." ::= { prtSAlarmEntry 7 } prtSAlarmCounter OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A counter - how many times the alarm occured (ON) since last clear operation or since last Reset." ::= { prtSAlarmEntry 8 } prtAlrMaskTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtAlrMaskEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= { prtAlr 2 } prtAlrMaskEntry OBJECT-TYPE SYNTAX PrtAlrMaskEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { prtAlrMaskPrtIdx} ::= { prtAlrMaskTable 1} PrtAlrMaskEntry ::= SEQUENCE { prtAlrMaskPrtIdx Integer32, prtAlrMask OCTET STRING } prtAlrMaskPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside/external, inside/internal. In the Kilomux, the port index is calculated as follows: 100*Slot+Ch. The external Ch numbers are 1..10, and the internal Ch numbers are 11..20. In the DXC : - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card in odd or even numbers, as follows: * For the outside/external ports, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside/internal ports, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 ." ::= { prtAlrMaskEntry 1} prtAlrMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) MAX-ACCESS read-write STATUS current DESCRIPTION "This object is a mask that indicates which port level alarms are masked. The masked alarms (their bit is set to '1') are neither sent to the manager, nor taken into account for alarm status and LEDs. Bit no. = Alarm code The bits that do not belong to the port level will be 0. This object is applicable only when prtGenAlrMaskAll=off (otherwise all port alarms are masked). Example: When Alarms having the codes 31 and 40 are masked, the value of this object will be 10080000000 (hex)." ::= { prtAlrMaskEntry 2 } --Port BERT table prtBertTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtBertEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table includes the BERT parameters, counters and commands. The configurable parameters: - prtBertPattern - prtBertInjectRate - prtBertTs are not Set per configuration (same for all Configurations) but start being applied by the Agent only upon successful Update/Download operation. Therefore, Set will enter the values to the Temporary Configuration of the agent, while Get will get the values of the Active Configuration." ::= { prtGen 5 } prtBertEntry OBJECT-TYPE SYNTAX PrtBertEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { prtBertPrtIdx} ::= { prtBertTable 1} PrtBertEntry ::= SEQUENCE { prtBertPrtIdx Integer32, prtBertPattern INTEGER, prtBertInjectRate INTEGER, prtBertInjectErrRateCmd INTEGER, prtBertInjectSingleErrCmd INTEGER, prtBertRunTime Integer32, prtBertESs Integer32, prtBertSyncLoss Integer32, prtBertErrorBits Integer32, prtBertClearCounters INTEGER, prtBertSyncStatus INTEGER, prtBertTs OCTET STRING, prtBertResult DisplayString (SIZE (0..255)) } prtBertPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside/external, inside/internal. In the Kilomux, the port index is calculated as follows: 100*Slot+Ch. The external Ch numbers are 1..10, and the internal Ch numbers are 11..20. In the DXC : - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card in odd or even numbers, as follows: * For the outside/external ports, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside/internal ports, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . In the MP : - first two digits will be: (IO slot number+10) - last one/two digits will be according to the external port number within the card: exPrt1 -> 1 exPrt2 -> 3 exPrt3 -> 5 exPrt4 -> 7 . " ::= { prtBertEntry 1} prtBertPattern OBJECT-TYPE SYNTAX INTEGER { p2E3m1 (1), p2E4m1 (2), p2E5m1 (3), p2E6m1 (4), p2E7m1 (5), p511 (6), p2E10m1 (7), p2047 (8), p2E15m1 (9), p2E17m1 (10), p2E18m1 (11), p2E20m1 (12), qrss (13), p2E21m1 (14), p2E22m1 (15), p2E23m1 (16), p2E25m1 (17), p2E28m1 (18), p2E29m1 (19), p2E31m1 (20), p2E32m1 (21), rj011 (22), p63 (23), p1M7S (24), p1S7M (25), alternate(26), mark (27), space (28), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the pattern of the BERT. p2Exxm1 = 2Exx-1. pxx = pattern xx. This object is the same for all configurations. notApplicable - when this object is not supported." ::= { prtBertEntry 2} prtBertInjectRate OBJECT-TYPE SYNTAX INTEGER { noError (1), r10Em1 (2), r10Em2 (3), r10Em3 (4), r10Em4 (5), r10Em5 (6), r10Em6 (7), r10Em7 (8), single (9), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the error rate injection of the BERT. r10Emx = 10E-x This object is the same for all configurations. single - single error injection. notApplicable - when this object is not supported." ::= { prtBertEntry 3} prtBertInjectErrRateCmd OBJECT-TYPE SYNTAX INTEGER { off (2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object controls activation/deactivation of the Error Rate Injection during BERT." ::= { prtBertEntry 4} prtBertInjectSingleErrCmd OBJECT-TYPE SYNTAX INTEGER { off (2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object enables to initiate a Single Error Injection during BERT (on). Upon completion, the value will automatically change to off(2)." ::= { prtBertEntry 5} prtBertRunTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates how much time (seconds) passed since BERT started to run." ::= { prtBertEntry 6} prtBertESs OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "How many Errored Seconds were detected since BERT started to run. Counter for Kmux and MP." ::= { prtBertEntry 7} prtBertSyncLoss OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "How many times Sync Loss was detected since BERT started to run. For some products: number of seconds in which Sync Loss occured since BERT started to run. See product specification." ::= { prtBertEntry 8} prtBertErrorBits OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "How many Error Bits were detected since BERT started to run." ::= { prtBertEntry 9} prtBertClearCounters OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this object to ON, will enforce a clear operation of some BERT Counters. Upon completion, the value will automatically change to off(2)." ::= { prtBertEntry 10} prtBertSyncStatus OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), syncLoss (2), sync (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Sync Status while BERT runs." ::= { prtBertEntry 11} prtBertTs OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..4)) MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates on which TSs of the selected port, BERT should be applied. Each Bit of the Octet represents a TS: 31 ......0 MSB LSB Bit 0 will not be used. If the bit value is '1' - BERT should be applied on this TS. For a T1 port, the valid raised bits ('1') are: 1..25. For an E1 port, the valid raised bits ('1') are: 1..31. Agents that do not support this feature will send SIZE 0." ::= { prtBertEntry 12} prtBertResult OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates Result of BERT for the selected port (number of error bits divided to the total number of data bits.) Applicable only if BERT is running on this port Agents that do not support this feature will send SIZE 0." ::= { prtBertEntry 13} --Port Monitoring Table - for Monitoring ports --The table is applicable only for DXC T1/E1/HS ports and Optimux-T3 prtMonTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtMonEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "For DXC, the write operation into the Table's Objects is valid only for the TmpCnfg entry (Scratch)." ::= { prtGen 6} prtMonEntry OBJECT-TYPE SYNTAX PrtMonEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtMonCnfgIdx, prtMonitoringIdx } ::= { prtMonTable 1} PrtMonEntry ::= SEQUENCE { prtMonCnfgIdx Integer32, prtMonitoringIdx Integer32, prtMonitoringEnable INTEGER, prtMonitoringTSs OCTET STRING, prtMonitoredPort Integer32, prtMonitoredTSs OCTET STRING } prtMonCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Idx of the Cnfg(1..255) being accessed. Idx of 255 relates to the TmpCnfg. For products that do not support configurations, 1 will be always used." ::= { prtMonEntry 1} prtMonitoringIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Monitoring Port Index. For DXC: The valid port number depends on the IO slot no., the installed card type and the port type: external, internal. * The external ports will according to the convention (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The internal ports will be according to the convention (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . For Optimux-T3: 255 (Not Applicable) will be always used. The Monitoring port is always the Station Clock (not considered an interface)." ::= { prtMonEntry 2} prtMonitoringEnable OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), disabled (2), enabled (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates if the prtMonitoringIdx is configured as a monitoring port or not. disabled = the port is NOT configured to monitor. Setting this object to this value will cause reset (to 0) of the prtMonitoringTSs and prtMonitoredTSs objects. enabled = the port IS configured to monitor. For Optimux-T3: always enabled (RO supported)." ::= {prtMonEntry 3} prtMonitoringTSs OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..4)) MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates which TSs of the Monitoring port, the test equipment should monitor. Each Bit of the Octet represents a TS: 31 ......0 MSB LSB Bit 0 will not be used. If the bit value is '1' - this TS should be monitored. For a T1 port, the valid raised bits ('1') are: 1..24. For an E1 port, the valid raised bits ('1') are: 1..31. Default: all bits='0' Agents that do not support this feature will send SIZE 0. This object can be Set as described only if prtMonitoringEnable=enabled. " ::= {prtMonEntry 4} prtMonitoredPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the MONITORED Port Index that the Monitoring port monitors. For DXC: The valid port number depends on the IO slot no., the installed card type and the port type: external, internal. * The external ports will according to the convention (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The internal ports will be according to the convention (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . * 100 - no port monitored For Optimux-T3: The valid channels are: 0 = no Ch monitored 1..21 or 1..28 (=CH1..CH21 or CH1..CH28) according to product's configuration." ::= { prtMonEntry 5} prtMonitoredTSs OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..4)) MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates which TSs of the Monitored port, should be monitored. Each Bit of the Octet represents a TS: 31 ......0 MSB LSB Bit 0 will not be used. If the bit value is '1' - this TS should be monitored. For a T1 port, the valid raised bits ('1') are: 1..24. For an E1 port, the valid raised bits ('1') are: 1..31. Default: all bits='0' Agents that do not support this feature will send SIZE 0. This object can be Set as described only if prtMonitoringEnable=enabled." ::= {prtMonEntry 6} -- Port Configuration Table -- This table is applicable only for KMUX ports prtCfgParam OBJECT IDENTIFIER ::= {prtGen 7} prtCfgParamTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtCfgParamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry. Parameters for the channels of the KMUX Cards: KMBE/New, KVF.6 family." ::= { prtCfgParam 1} prtCfgParamEntry OBJECT-TYPE SYNTAX PrtCfgParamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtCfgParamCnfgIdx, prtCfgParamIdx } ::= { prtCfgParamTable 1} PrtCfgParamEntry ::= SEQUENCE { prtCfgParamCnfgIdx Integer32, prtCfgParamIdx Integer32, prtCfgParamSlt INTEGER, prtCfgParamOperatedMl INTEGER, prtCfgParamMlAtoMlBPrio INTEGER, prtCfgParamMlBtoMlAPrio INTEGER, prtCfgParamInbandLoopDetection INTEGER } prtCfgParamCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg." ::= {prtCfgParamEntry 1} prtCfgParamIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier of the port (within the card when applicable). - For KM-2100: Slot*100+Ch external ports: Ch=1..10 internal ports (sub-channels): Ch=11..20. - For FCD-T1/E1: SUB=113, CH1=122, CH2=124. " ::= {prtCfgParamEntry 2} prtCfgParamSlt OBJECT-TYPE SYNTAX INTEGER { kmxIO1 (107), kmxIO2 (108), kmxIO3 (109), kmxIO4 (110), kmxIO5 (111), kmxIO6 (112), kmxIO7 (113), kmxIO8 (114), kmxIO9 (115), kmxIO10(116), kmxIO11(117), kmxIO12(118), notApplicable(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique number to identify the slot where the card is inserted in. In the 2104 Unit the entries kmxIO5(111)..kmxIO12(118) are not valid. notApplicable(255) - for products that do not have Slots." ::= {prtCfgParamEntry 3} prtCfgParamOperatedMl OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), kmxMlA (103), kmxMlB (104) } MAX-ACCESS read-write STATUS current DESCRIPTION "The main link for this channel. The field is relevant only for ML modes of Dual, Priority Bumping and Switched Backup." ::= {prtCfgParamEntry 4} prtCfgParamMlAtoMlBPrio OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), low (2), high (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "ML-A to ML-B Priority. The field is relevant only for ML modes of Priority Bumping and Switched Backup." ::= {prtCfgParamEntry 5} prtCfgParamMlBtoMlAPrio OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), low (2), high (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "ML-B to ML-A Priority. The field is relevant only for ML modes of Priority Bumping." ::= {prtCfgParamEntry 6} prtCfgParamInbandLoopDetection OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), disabled (2), enabled (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Inband Loop Detection. The field is relevant for the following FCD-T1/E1 ports: SUB, CH1, CH2." ::= {prtCfgParamEntry 7} --DACS T1/E1 port specific parameters --DACS T1/E1 port statistics parameters. --These parameters are in addition to those of RFC-1406 MIB. prtT1E1StatTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtT1E1StatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "T1/E1 port statistics table." ::= { prtT1E1 1} prtT1E1StatEntry OBJECT-TYPE SYNTAX PrtT1E1StatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " An entry in the T1/E1 port statistics table." INDEX { prtT1E1SPrtIdx } ::= { prtT1E1StatTable 1} PrtT1E1StatEntry ::= SEQUENCE { prtT1E1SPrtIdx Integer32, prtT1E1SSlt INTEGER, prtT1E1OosCount Gauge32, prtT1E1BpvLastMin Gauge32, prtT1E1BpvMax Gauge32 } prtT1E1SPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number. The same numbering as for prtGenPrtIdx. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside. * The outside ports will be the T1/E1 cards ports. The convention used will be (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 ." ::= { prtT1E1StatEntry 1} prtT1E1SSlt OBJECT-TYPE SYNTAX INTEGER { clA (3), clB (4), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), io13 (17), io14 (18), io15 (19), standAlone (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique number to identify the slot where the card is inserted in. When the unit is stand-alone, this object is not applicable and 255 will be used." ::= { prtT1E1StatEntry 2} prtT1E1OosCount OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object is applicable only for an E1 active port. It provides the number of red alarm events since the last count clearing." ::= { prtT1E1StatEntry 3 } prtT1E1BpvLastMin OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object is applicable only for an E1 active port. It provides the number of BPV (BiPolar Violation) events detected during the last minute." ::= { prtT1E1StatEntry 4 } prtT1E1BpvMax OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object is applicable only for an E1 active port. It provides the maximal number of BPV (BiPolar Violation) events (per minute), detected during the worst minute." ::= { prtT1E1StatEntry 5 } --DACS T1/E1 port configuration parameters. -- --Objects 2..9 appear in RFC-1406 MIB (dsx1ConfigTable) as RW --objects. They were entered in this private MIB, because in --RFC-1406 MIB there is no reference to configuration number. prtT1E1CnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtT1E1CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "T1/E1 port configuration table." ::= { prtT1E1 2} prtT1E1CnfgEntry OBJECT-TYPE SYNTAX PrtT1E1CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " An entry in the T1/E1 port configuration table." INDEX { prtT1E1CnfgIdx, prtT1E1PrtIdx } ::= { prtT1E1CnfgTable 1} PrtT1E1CnfgEntry ::= SEQUENCE { prtT1E1CnfgIdx Integer32, prtT1E1PrtIdx Integer32, prtT1E1Slt INTEGER, prtT1E1LineType INTEGER, prtT1E1LineCode INTEGER, prtT1E1SignalMode INTEGER, prtT1E1Fdl INTEGER, prtT1E1FdlMode INTEGER, prtT1E1Sync INTEGER, prtT1E1CGA INTEGER, prtT1E1IdleCode OCTET STRING, prtT1E1OosSignal INTEGER, prtT1E1VoiceOos OCTET STRING, prtT1E1DataOos OCTET STRING, prtT1E1LineLengthMask INTEGER, prtT1E1TxGainMask INTEGER, prtT1E1InbandMng INTEGER, prtT1E1InbandMngRate INTEGER, prtT1E1DedicatedTs Integer32, prtT1E1InbandMngRoutProt INTEGER, prtT1E1LinkMode INTEGER, prtT1E1Multiplier INTEGER, prtT1E1RxGain INTEGER, prtT1E1RAI INTEGER, prtT1E1LineMode INTEGER, prtT1E1TS0SaBits OCTET STRING, prtT1E1ConnectedTS INTEGER, prtT1E1Ts0SaBit INTEGER, prtT1E1SameFeCnfg INTEGER, prtT1E1RemCrc4 INTEGER, prtT1E1MaxTSs Integer32, prtT1E1EocTsConfig INTEGER } prtT1E1CnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config. " ::= { prtT1E1CnfgEntry 1} prtT1E1PrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number. The same numbering as for prtGenPrtIdx. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside. In the DXC : - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card in odd or even numbers, as follows: * For the outside/external ports, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside/internal ports, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . In the Kilomux, the port index is calculated as follows: 100*Slot+Ch. The external Ch numbers are 1..10, and the internal Ch numbers are 11..20." ::= { prtT1E1CnfgEntry 2} prtT1E1Slt OBJECT-TYPE SYNTAX INTEGER { clA (3), clB (4), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), io13 (17), io14 (18), io15 (19), kmxMlA (103), kmxMlB (104), kmxOpt (106), kmxIO1 (107), kmxIO2 (108), kmxIO3 (109), kmxIO4 (110), kmxIO5 (111), kmxIO6 (112), kmxIO7 (113), kmxIO8 (114), kmxIO9 (115), kmxIO10(116), kmxIO11(117), kmxIO12(118), standAlone (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique number to identify the slot where the card is inserted in. When the unit is stand-alone, this object is not applicable and 255 will be used." ::= { prtT1E1CnfgEntry 3} prtT1E1LineType OBJECT-TYPE SYNTAX INTEGER { other (1), esf (2), d4 (3), --sf e1 (4), e1Crc (5), e1MF (6), e1CrcMF (7), unframed (8) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable indicates the variety of T1/E1 Line implementing this circuit. The type of circuit affects the number of bits per second that the circuit can reasonably carry, as well as the interpretation of the usage and error statistics. The values, in sequence, describe: TITLE: SPECIFICATION: esf Extended SuperFrame DS1 d4 AT&T D4 format DS1 - SF e1 CCITT Recommendation G.704 (Table 4a) - G732N e1Crc CCITT Recommendation G.704 (Table 4b) - G732N with CRC e1MF G.704 (Table 4a) with TS16 multiframing enabled - G732S e1CrcMF G.704 (Table 4b) with TS16 multiframing enabled - G732S with CRC unframed T1 - applicable values: (1),(2),(3),(8) E1 - applicable values: (1),(4),(5),(6),(7),(8) " ::= { prtT1E1CnfgEntry 4 } prtT1E1LineCode OBJECT-TYPE SYNTAX INTEGER { jbzs (1), b8zs (2), hdb3 (3), zbtsi(4), ami (5), other(6) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable describes the variety of Zero Code Suppression used on the link, which in turn affects a number of its characteristics. jbzs=b7zs refers the Jammed Bit Zero Suppres- sion, in which the AT&T specification of at least one pulse every 8 bit periods is literal- ly implemented by forcing a pulse in bit 8 of each channel. Thus, only seven bits per chan- nel, or 1.344 Mbps, is available for data (used for T1). b8zs refers to the use of a specified pattern of normal bits and bipolar violations which are used to replace a sequence of eight zero bits (used for T1). ANSI Clear Channels may use zbtsi, or Zero Byte Time Slot Interchange. E1 links, with or without CRC, use hdb3 or ami (= TRAN). amI (=TRAN) refers to a mode wherein no zero code suppression is present and the line encoding does not solve the problem directly. In this application, the higher layer must provide data which meets or exceeds the pulse density re- quirements, such as inverting HDLC data." ::= { prtT1E1CnfgEntry 5 } prtT1E1SignalMode OBJECT-TYPE SYNTAX INTEGER { none (1), robbedBit (2), bitOriented (3), --CAS messageOriented (4) --CCS } MAX-ACCESS read-write STATUS current DESCRIPTION "'none' indicates that no bits are reserved for signaling on this channel. 'robbedBit' indicates that T1 Robbed Bit Signaling is in use. 'bitOriented' indicates that E1 Channel Associated Signaling (CAS) is in use. 'messageOriented' indicates that Common Channel Signaling (CCS) is in use either on channel 16 of an E1 link or channel 24 of a T1." ::= { prtT1E1CnfgEntry 6 } prtT1E1Fdl OBJECT-TYPE SYNTAX INTEGER { other (1), ansi-T1-403(2), att-54016 (4), fdl-none (8), transFdl (16) } MAX-ACCESS read-write STATUS current DESCRIPTION "This bitmap describes the use of the facili- ties data link, and is the sum of the capabili- ties: 'other' indicates that a protocol other than one following is used. 'ansi-T1-403' refers to the FDL exchange recommended by ANSI. 'att-54016' refers to ESF FDL exchanges. 'fdl-none' indicates that the device does not use the FDL. 'transFdl' indicates transition between two ports of the same card. " ::= { prtT1E1CnfgEntry 7 } prtT1E1FdlMode OBJECT-TYPE SYNTAX INTEGER { other (1), user (2), carrier (3), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION " Fdl Mode of the T1 selected port. notApplicable - will be used for an E1 port." ::= { prtT1E1CnfgEntry 8 } prtT1E1Sync OBJECT-TYPE SYNTAX INTEGER { other (1), tr62411(2), ccitt (3), fast (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object enables returning to normal operation, after the end of a main/sub link red alarm event, in reduced time. 'tr62411' - complies with AT&T TR-62411 (after 10 seconds). Applicable for both T1 and E1 interfaces. 'ccitt' - complies with CCITT standard. Applicable only for E1 interfaces. 'fast' - after 1 second." ::= { prtT1E1CnfgEntry 9 } prtT1E1CGA OBJECT-TYPE SYNTAX INTEGER { none (1), trans(2), full (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object selects the method used to signal the CGA state to the other end, through the main/sub link. 'none' - non-transparent mode. When one of the links (main/sub) will be in Out Of Service state, both 'Data/Voice Oos' and 'Oos Signal' will be transmitted to the other end. 'trans' - when one of the links (main/sub) will be in Out Of Service state, 'Data/Voice Oos' will be transmitted to the other end. 'full' - fully-transparent mode. When one of the links (main/sub) will be in Out Of Service state, neither 'Data/Voice Oos' nor 'Oos Signal' will be transmitted to the other end." ::= { prtT1E1CnfgEntry 10 } prtT1E1IdleCode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..4)) MAX-ACCESS read-write STATUS current DESCRIPTION "This object selects the code transmitted to fill idle (unused) time slots in the main link frame. Valid range: (0 - FF HEX) ." ::= { prtT1E1CnfgEntry 11 } prtT1E1OosSignal OBJECT-TYPE SYNTAX INTEGER { notsupported (2), forcedIdle (3), forcedBusy (4), busyIdle (5), idleBusy (6) } MAX-ACCESS read-write STATUS current DESCRIPTION "'idle' = '0' = on-hook, idle state 'busy' = '1' = off-hook, busy state 'forcedIdle' = SP = both A and B signaling bits are forced to '0' during out-of-service periods. 'forcedBusy' = MK = both A and B signaling bits are forced to '1' during out-of-service periods. 'busyIdle' = MK_SP = A and B bits are forced to '1' for 2.5 seconds; then they are switched to '0' until out-of-service condition disappears. 'idleBusy' = SP_MK = A and B bits are forced to '0' for 2.5 seconds; then they are switched to '1' until out-of-service condition disappears. - for T1: '0'=0 ; '1'=1 - for E1: '0'=1 ; '1'=0 " ::= { prtT1E1CnfgEntry 12 } prtT1E1VoiceOos OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..4)) MAX-ACCESS read-write STATUS current DESCRIPTION "Voice Out-Of-Service code. Valid range: (0 - FF HEX). For agents that do not support this feature, the value will always be 0." ::= { prtT1E1CnfgEntry 13 } prtT1E1DataOos OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..4)) MAX-ACCESS read-write STATUS current DESCRIPTION "Data Out-Of-Service code. Valid range: (0 - FF HEX). For agents that do not support this feature, the value will always be 0." ::= { prtT1E1CnfgEntry 14 } prtT1E1LineLengthMask OBJECT-TYPE SYNTAX INTEGER { unknown (1), len0p133ft (2), len134p266ft (3), len267p399ft (4), len400p533ft (5), len534p655ft (6), fcc68 (7) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute is the line length mask parameter used only for T1/DSU interfaces. len400p533ft=length range: 400ft to 533ft 'fcc68' - provides compliance with the FCC 68.308 Option A output pulse mask. " ::= { prtT1E1CnfgEntry 15 } prtT1E1TxGainMask OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), txGain0db (2), txGain7dot5db (3), txGain15db (4), txGain22dot5db (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute is the tx gain mask parameter (dB), used only for T1/CSU interfaces." ::= { prtT1E1CnfgEntry 16 } prtT1E1InbandMng OBJECT-TYPE SYNTAX INTEGER { off (2), fdlOrTs0 (3), dedicatedTs (4), dedicatedPpp(5), dedicatedFr (6), internal (7) } MAX-ACCESS read-write STATUS current DESCRIPTION "A unique number to identify an Inband management over the link. internal - supported by KM-2100 only. It means that the management is internal to the frame. It takes part of the ML Frame bits (instead of data)." ::= {prtT1E1CnfgEntry 17} prtT1E1InbandMngRate OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), r4k (2), r8k (3), r12k (4), r16k (5), r32k (6), r64k (7), r20k (8) } MAX-ACCESS read-write STATUS current DESCRIPTION "A unique number to identify the rate of the Inband management. It is required only for E1 links and is applicable only when prtExT1E1InbandMng selected is FdlOrTs0 or dedicatedTs." ::= {prtT1E1CnfgEntry 18} prtT1E1DedicatedTs OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value is differently determined for different products. There are two methods: 1) A unique number to identify Dedicated TS of the T1/E1 port. It is applicable only when prtExT1E1InbandMng selected is dedicatedTs. 1..24 - Dedicated TS of T1 1..31 - Dedicated TS of E1 255 - notApplicable (for agents that do not support this feature) Other values are invalid. 2) For FCD-STM, up to five TSs may be dedicated to management. This object value is the Sum (sigma) of 2**n, where n =TS-1 e.g. Time slots 3,5,7,9,11 are dedicated to management: 2** 2 +2** 4 +2** 6 +2** 8 +2**10 = 4+16+64+256+1024=1364 User should consult the product specification, to find out the method employed." ::= {prtT1E1CnfgEntry 19} prtT1E1InbandMngRoutProt OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), none (2), proprietary (3), rip2 (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Inband Mng Routing Protocol of the port. When prtT1E1InbandMng is 'dedicatedPpp'-'proprietary' and 'rip2' are applicable. For other values - only 'proprietary' is applicable. For FCD-M and FCD-A: When prtT1E1InbandMng is 'dedicatedPpp' or 'dedicatedFr': 'None', 'proprietary' and 'rip2' are applicable. When prtT1E1InbandMng is 'fdlOrTS0' or 'dedicatedTs': 'None' and 'proprietary' are applicable. When prtT1E1InbandMng is 'off': 'None' is applicable." ::= {prtT1E1CnfgEntry 20} prtT1E1LinkMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), regular (2), transparent (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "regular - TSs are connected by user via TS Assignment only transparent - when a port with this Link Mode is connected to an internal T1/E1 port of a T3/E3 card, TS0, TS16 and Fbit are transparently transferred to the E3/T3 stream." ::= {prtT1E1CnfgEntry 21} prtT1E1Multiplier OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), br56 (2), br64 (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The data rate of each TS. The multiplier values can be 56 kbps or 64 kbps. For T1 only." ::= { prtT1E1CnfgEntry 22 } prtT1E1RxGain OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), rxGain12dB (2), rxGain30dB (3), rxGain36dB (4), shortHaul (5), longHaul (6) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute is the rx volume (dB)." ::= { prtT1E1CnfgEntry 23 } prtT1E1RAI OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), off (2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Remote Alarm Signal" ::= { prtT1E1CnfgEntry 24 } prtT1E1LineMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), csu (2), dsu (3), ltu (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Interface type of the port. For T1 - csu, dsu are the valid values For E1 - dsu, ltu are the valid values" ::= { prtT1E1CnfgEntry 25 } prtT1E1TS0SaBits OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "This object is applicable only for E1 ports. For T1, string size will be 0. For E1, it enables user to select the use of TS0 Sa Bits 4..8, by 3 octets: The order (in hexa display): free Sa-Bit-4 Sa-Bit-5 Sa-Bit-6 Sa-Bit-7 Sa-Bit-8 |___________| |________________| |________________| MSByte LSByte Each Sa Bit will be represented by a nibble, having the following meaning: 0000 = zero 0001 = one 0010 = management 0011 = transparent the rest are reserved for future use." ::= { prtT1E1CnfgEntry 26 } prtT1E1ConnectedTS OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), no (2), yes (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates if there is any connected TS for this interface." ::= { prtT1E1CnfgEntry 27 } prtT1E1Ts0SaBit OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), noMng (2), mng (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter indicates whether to send TS 0, or not. noMng= TS 0 is looped, therefore not sent. mng= TS 0 isn't looped, therefore it is sent." ::= { prtT1E1CnfgEntry 28 } prtT1E1SameFeCnfg OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter indicates whether the same E1 configuration parameters and TS assignment are set both to the local and remote device. Read-Write access is applicable only in G732N framed mode. For G732S and UNFRAMED this parameter is set by agent to YES and is Read Only. In Case of conflict during power-up between the central and remote, the value set by the central unit is the valid one." ::= { prtT1E1CnfgEntry 29 } prtT1E1RemCrc4 OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether the E1 of the Remote device connected to this E1 port, will have CRC-4 or not." ::= { prtT1E1CnfgEntry 30 } prtT1E1MaxTSs OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object is applicable only for DXC D4T1, D4E1, D8T1, D8E1 external ports and D8GSL internal E1 ports. It is relevant only when sysCIntTsAllocMode=static(2). 255=not applicable If prtT1E1LineType=unframed(8), the value of this object must be 32. Else, the valid values are 0..31." ::= { prtT1E1CnfgEntry 31} prtT1E1EocTsConfig OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disabled (2), enabled (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether the use of EOC for TS Configuration is enabled or not." ::= { prtT1E1CnfgEntry 32 } --prtT1E1 Last FDL Message Table - Statistics prtT1E1FdlMsgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtT1E1FdlMsgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is applicable for a T1 interface with 'esf' LineType or E1 interface, when CRC is enabled (LineType)." ::= { prtT1E1 3} prtT1E1FdlMsgEntry OBJECT-TYPE SYNTAX PrtT1E1FdlMsgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtT1E1FdlMsgPrtIdx, prtT1E1FdlMsgFdlType} ::= { prtT1E1FdlMsgTable 1} PrtT1E1FdlMsgEntry ::= SEQUENCE { prtT1E1FdlMsgPrtIdx Integer32, prtT1E1FdlMsgFdlType INTEGER, prtT1E1FdlMsgSlt INTEGER, prtT1E1FdlMsg OCTET STRING } prtT1E1FdlMsgPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number. The same numbering as for prtGenPrtIdx. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside. * The outside ports will be the T1/E1 cards ports. The convention used will be (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 ." ::= { prtT1E1FdlMsgEntry 1} prtT1E1FdlMsgFdlType OBJECT-TYPE SYNTAX INTEGER { send (1), receive (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Fdl type reference of the Fdl message." ::= { prtT1E1FdlMsgEntry 2} prtT1E1FdlMsgSlt OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), io13 (17), io14 (18), io15 (19), standAlone (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique number to identify the slot where the card is inserted in. When the unit is stand-alone, this object is not applicable and 255 will be used." ::= { prtT1E1FdlMsgEntry 3} prtT1E1FdlMsg OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "FDL message." ::= { prtT1E1FdlMsgEntry 4} --prtHS specific parameters (configuration & status) table prtHSParamTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtHSParamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= { prtHS 1 } prtHSParamEntry OBJECT-TYPE SYNTAX PrtHSParamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { prtHSCnfgIdx, prtHSPrtIdx } ::= { prtHSParamTable 1} PrtHSParamEntry ::= SEQUENCE { prtHSCnfgIdx Integer32, prtHSPrtIdx Integer32, prtHSSlt INTEGER, prtHSRate INTEGER, prtHSFifoSize INTEGER, prtHSClkMode INTEGER, prtHSCTS INTEGER, prtHSRtsState INTEGER, prtHSInbandLoopback INTEGER, prtHSInbandLoopPatternCfg INTEGER, prtHSInbandLoopActPattern DisplayString, prtHSInbandLoopDeactPattern DisplayString, prtHSDCD INTEGER } prtHSCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config. " ::= { prtHSParamEntry 1} prtHSPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside, SP. * The inside ports will be the HS cards ports. The convention used will be (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 ." ::= { prtHSParamEntry 2} prtHSSlt OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), io13 (17), io14 (18), io15 (19), standAlone (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique number to identify the slot where the card is inserted in. When the unit is stand-alone, this object is not applicable and 255 will be used." ::= { prtHSParamEntry 3} prtHSRate OBJECT-TYPE SYNTAX INTEGER { r0x56eq0Kbps (1), r1x56eq56Kbps (2), r2x56eq112Kbps (3), r3x56eq168Kbps (4), r4x56eq224Kbps (5), r5x56eq280Kbps (6), r6x56eq336Kbps (7), r7x56eq392Kbps (8), r8x56eq448Kbps (9), r9x56eq504Kbps (10), r10x56eq560Kbps (11), r11x56eq616Kbps (12), r12x56eq672Kbps (13), r13x56eq728Kbps (14), r14x56eq784Kbps (15), r15x56eq840Kbps (16), r16x56eq896Kbps (17), r17x56eq952Kbps (18), r18x56eq1008Kbps(19), r19x56eq1064Kbps(20), r20x56eq1120Kbps(21), r21x56eq1176Kbps(22), r22x56eq1232Kbps(23), r23x56eq1288Kbps(24), r24x56eq1344Kbps(25), r25x56eq1400Kbps(26), r26x56eq1456Kbps(27), r27x56eq1512Kbps(28), r28x56eq1568Kbps(29), r29x56eq1624Kbps(30), r30x56eq1680Kbps(31), r31x56eq1736Kbps(32), r0x64eq0Kbps (33), r1x64eq64Kbps (34), r2x64eq128Kbps (35), r3x64eq192Kbps (36), r4x64eq256Kbps (37), r5x64eq320Kbps (38), r6x64eq384Kbps (39), r7x64eq448Kbps (40), r8x64eq512Kbps (41), r9x64eq576Kbps (42), r10x64eq640Kbps (43), r11x64eq704Kbps (44), r12x64eq768Kbps (45), r13x64eq832Kbps (46), r14x64eq896Kbps (47), r15x64eq960Kbps (48), r16x64eq1024Kbps(49), r17x64eq1088Kbps(50), r18x64eq1152Kbps(51), r19x64eq1216Kbps(52), r20x64eq1280Kbps(53), r21x64eq1344Kbps(54), r22x64eq1408Kbps(55), r23x64eq1472Kbps(56), r24x64eq1536Kbps(57), r25x64eq1600Kbps(58), r26x64eq1664Kbps(59), r27x64eq1728Kbps(60), r28x64eq1792Kbps(61), r29x64eq1856Kbps(62), r30x64eq1920Kbps(63), r31x64eq1984Kbps(64), r32x64eq2048Kbps(65), r32x56eq1792Kbps(66), r64x64eq4096Kbps(67), auto (200) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the port rate (speed). auto - rate is selected automatically by system." ::= { prtHSParamEntry 4} prtHSFifoSize OBJECT-TYPE SYNTAX INTEGER { auto (1), b32bit (2), b60bit (3), b104bit (4), b144bit (5), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object selects the size of the user data channel buffer FIFO used in the DTE2 mode. In the other modes, buffer size is automatically set by the DACS agent. Buffer FIFO size in bits, corresponds to FIFO lengths of +/-16, +/-30, +/-52, +/-72 bits." ::= { prtHSParamEntry 5} prtHSClkMode OBJECT-TYPE SYNTAX INTEGER { dce (1), dte1 (2), dte2 (3), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Clock Mode of the user data channel. dce - DACS operates as a DCE and provides transmit and receive clocks to the synchronous user DTE. dte1- DACS supplies the receive clock to the user equipment and accepts the user transmit clock. dte2- DACS requires transmit and receive clocks from the user equipment." ::= { prtHSParamEntry 6} prtHSCTS OBJECT-TYPE SYNTAX INTEGER { on (1), rts (2), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selection of CTS line state in the user data channel. on - CTS continuously ON. rts - CTS line follows the RTS line." ::= { prtHSParamEntry 7} prtHSRtsState OBJECT-TYPE SYNTAX INTEGER { off (2), on (3), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "RTS state of the port." ::= { prtHSParamEntry 8} prtHSInbandLoopback OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disabled (2), enabled (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates if Inband Loopback from the Network should be enabled or disabled." ::= {prtHSParamEntry 9} prtHSInbandLoopPatternCfg OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), rdlLoop (2), userConfig (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates if Inband Loop polynomial pattern will be according to RDL Loop (the standard) or User Configurated according to prtHSActivatePolyPattern and prtHSDeactivatePolyPattern." ::= {prtHSParamEntry 10} prtHSInbandLoopActPattern OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This object is a binary string of up to 8 bits. Though the syntax allows for any ASCII characters, for this object only '0' or '1' characters are valid. The string determines coefficients of the polynomial pattern sent to the port in order to Activate the Inband Loop. This object is relevant only when prtHSInbandLoopPatternCfg=userConfig." ::= {prtHSParamEntry 11} prtHSInbandLoopDeactPattern OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This object is a binary string of up to 8 bits. Though the syntax allows for any ASCII characters, for this object only '0' or '1' characters are valid. The string determines coefficients of the polynomial pattern sent to the port in order to Deactivate the Inband Loop. This object is relevant only when prtHSInbandLoopPatternCfg=userConfig." ::= {prtHSParamEntry 12} prtHSDCD OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), linkOK (2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selection of DCD line state in the user data channel. linkOK - DCD line is ON only when active link is OK. on - DCD continuously ON." ::= { prtHSParamEntry 13} prtHSBertTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtHSBertEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= { prtHS 2 } prtHSBertEntry OBJECT-TYPE SYNTAX PrtHSBertEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { prtHSBertPrtIdx } ::= { prtHSBertTable 1} PrtHSBertEntry ::= SEQUENCE { prtHSBertPrtIdx Integer32, prtHSBertSlt INTEGER, prtHSBertCountClr INTEGER, prtHSBertTestResult Integer32 } prtHSBertPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside, SP. * The inside ports will be the HS cards ports. The convention used will be (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 ." ::= { prtHSBertEntry 1} prtHSBertSlt OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), io13 (17), io14 (18), io15 (19), standAlone (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique number to identify the slot where the card is inserted in. When the unit is stand-alone, this object is not applicable and 255 will be used." ::= { prtHSBertEntry 2} prtHSBertCountClr OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this object (to on) initiate bert counter clear operation. Valid only when bert test is active on the specific port. (Every time a new bert test starts, the counter is automatically cleared; this command enables clearing the counter while the test is running)." ::= { prtHSBertEntry 3} prtHSBertTestResult OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the number of Bit Error Rate indicated during the BERT test. Active only when bert test is running on the selected port." ::= { prtHSBertEntry 4} --prt SP specific configuration parameters prtSpCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtSpCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= {prtSP 1} prtSpCnfgEntry OBJECT-TYPE SYNTAX PrtSpCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "All the entries at this table are identical(have the same value) at all the configurations(1..255) except at the TmpCnfg. - For products supporting more than one configuration, the write operation into the Table Objects is valid only at the TmpCnfg entry. - For products that do not support configurations, the write operation into the Table Objects will be to prtSpCnfgIdx=1." INDEX {prtSpCnfgIdx, prtSpPrtIdx } ::= { prtSpCnfgTable 1} PrtSpCnfgEntry ::= SEQUENCE { prtSpCnfgIdx Integer32, prtSpPrtIdx Integer32, prtSpUsage INTEGER, prtSpRate INTEGER, prtSpDataBits INTEGER, prtSpParity INTEGER, prtSpCallOutMode INTEGER, prtSpInterface INTEGER, prtSpCTS INTEGER, prtSpDcdDelay INTEGER, prtSpDsr INTEGER, prtSpNoOfRetries Integer32, prtSpWaitForConnect INTEGER, prtSpDialMode INTEGER, prtSpAltNumMode INTEGER, prtSpPrimaryNum DisplayString, prtSpAltNum DisplayString, prtSpRoutProtocol INTEGER, prtSpCmd OCTET STRING, prtSpActCallOut INTEGER, prtSpAlrRelayMode INTEGER, prtSpStopBits INTEGER } prtSpCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg(1..255) being accessed. Idx of 255 relates to the TmpCnfg." ::= { prtSpCnfgEntry 1} prtSpPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number of the SPor DP port. For DXC, it is the port in the active DCL card: - SP = 1 - NP ; DP = 2 For Kilomux, the port index is calculated as follows: 100*Slot+Ch. For FCD, PRBi, the SP port index=1. For Optimux-T3, the SP port index=71." ::= { prtSpCnfgEntry 2} prtSpUsage OBJECT-TYPE SYNTAX INTEGER { unknown (1), noUse (2), nmsSlip (3), nmsPpp (4), muxSlip (5), muxPpp (6), terminal(7), dialOut (8) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates what is the usage of the port." ::= { prtSpCnfgEntry 3} prtSpRate OBJECT-TYPE SYNTAX INTEGER { auto (1), s300bps (2), s1200bps (3), s2400bps (4), s4800bps (5), s9600bps (6), s19200bps (7), s38400bps (8), s57600bps (9), s115200bps(10) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the operation rate (speed) of the port. auto - automatic rate selection, by the agent." ::= { prtSpCnfgEntry 4} prtSpDataBits OBJECT-TYPE SYNTAX INTEGER { dataBits7 (1), dataBits8 (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the number of data bits in async frame" ::= { prtSpCnfgEntry 5} prtSpParity OBJECT-TYPE SYNTAX INTEGER { none (1), odd (2), even (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the parity mode in async frame" ::= { prtSpCnfgEntry 6} prtSpCallOutMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), none (2), all (3), major (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the call-out mode. For DXC - this object is applicable only for the DP port (2)." ::= { prtSpCnfgEntry 7} prtSpInterface OBJECT-TYPE SYNTAX INTEGER { dce (1), dte (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the supervisory port interface. dce - the DACS appears as a DCE for the port. dte - the DACS operates as a DTE, for connection via modem, for the port." ::= { prtSpCnfgEntry 8} prtSpCTS OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), on (2), rts (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "CTS line state. This object is applicable only for port (1) = SP" ::= { prtSpCnfgEntry 9} prtSpDcdDelay OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), d0 (2), d10 (3), d50 (4), d100 (5), d200 (6), d300 (7) } MAX-ACCESS read-write STATUS current DESCRIPTION "DCD delay in msec. d10 = delay of 10msec. This object is applicable only for port (1) = SP" ::= { prtSpCnfgEntry 10} prtSpDsr OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), on (2), dtr (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "DSR line state. This object is applicable only for port (1) = SP" ::= { prtSpCnfgEntry 11} prtSpNoOfRetries OBJECT-TYPE SYNTAX Integer32 (0..8) MAX-ACCESS read-write STATUS current DESCRIPTION "For DXC - this object is applicable only for port (2) = DP. The number of dialing retries requested. Default = 0" ::= { prtSpCnfgEntry 12} prtSpWaitForConnect OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), t30sec (2), t45sec (3), t60sec (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "For DXC - this object is applicable only for port (2) = DP. Waiting time for connect, in seconds. Default = 30 sec." ::= { prtSpCnfgEntry 13} prtSpDialMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), tone (2), pulse (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "For DXC - this object is applicable only for port (2) = DP. Dialing mode. Default=tone" ::= { prtSpCnfgEntry 14} prtSpAltNumMode OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "For DXC - this object is applicable only for port (2) = DP. It determines wether to use the alternate number or not. Default = no." ::= { prtSpCnfgEntry 15} prtSpPrimaryNum OBJECT-TYPE SYNTAX DisplayString (SIZE(0..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "For DXC - this object is applicable only for port (2) = DP. It is the Primary dialing number. " ::= { prtSpCnfgEntry 16} prtSpAltNum OBJECT-TYPE SYNTAX DisplayString (SIZE(0..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "For DXC - this object is applicable only for port (2) = DP. It is the Alternate dialing number. This number is applicable only if prtSpAltNumMode is 'yes'." ::= { prtSpCnfgEntry 17} prtSpRoutProtocol OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), none (2), proprietary (3), rip2 (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the routing protocol of the port. notApplicable - for DP." ::= { prtSpCnfgEntry 18} prtSpCmd OBJECT-TYPE SYNTAX OCTET STRING (SIZE (20)) MAX-ACCESS read-write STATUS current DESCRIPTION "SP Command. For LRS this parameter will be used for a Modem Command. Upon NMS's Get operation for devices that this parameter is notApplicable, agent will send NULL string." ::= { prtSpCnfgEntry 19} prtSpActCallOut OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), always (2), linkFail (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates when to Activate Call-Out. It is used by FCD-T1/E1. always - to activate call-out always. linkFail - to activate call-out only when Link of Inband Management fails." ::= { prtSpCnfgEntry 20} prtSpAlrRelayMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), normal (2), invert (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the Alarm Relay Mode. notApplicable - for DP." ::= { prtSpCnfgEntry 21} prtSpStopBits OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), stopBits1 (2), stopBits1dot5 (3), stopBits2 (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates number of stop bits in an async frame." ::= { prtSpCnfgEntry 22} --prt DIM (DXC Inverse Multiplexer) specific parameters prtDimCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtDimCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= {prtDim 1} prtDimCnfgEntry OBJECT-TYPE SYNTAX PrtDimCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only for the TmpCnfg entry (prtDimCnfgIdx=255)." INDEX {prtDimCnfgIdx, prtDimIdx } ::= { prtDimCnfgTable 1} PrtDimCnfgEntry ::= SEQUENCE { prtDimCnfgIdx Integer32, prtDimIdx Integer32, prtDimTxMode INTEGER, prtDimPolarity INTEGER, prtDimClkMode INTEGER, prtDimMaxDelay INTEGER, prtDimMng INTEGER } prtDimCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg(1..255) being accessed. Idx of 255 relates to the TmpCnfg." ::= { prtDimCnfgEntry 1} prtDimIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number of the DIM card. The convention used for DXC: (IO slot number+10)*10 + 1 Example: port1 of IO slot 11 will be: 211 ." ::= { prtDimCnfgEntry 2} prtDimTxMode OBJECT-TYPE SYNTAX INTEGER { regularTx (2), broadcast (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Tx mode. regularTx - the links are connected to a similar outfit on the other side. In this mode, if a link fails, the transmitted bandwidth is decreased accordingly. broadcast - the links are connected to MORE than one similar outfit on the other side. In this mode, if a link fails, the transmitted bandwidth is not affected " ::= { prtDimCnfgEntry 3} prtDimPolarity OBJECT-TYPE SYNTAX INTEGER { normalClk (2), inverted (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Polarity." ::= { prtDimCnfgEntry 4} prtDimClkMode OBJECT-TYPE SYNTAX INTEGER { extDce (2), dce (3), smooth (4), extSmooth(5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Clock Mode. smooth - a clock that is not 'pulsed'(has no 'gaps'). In this mode the DXC does NOT receive back the clock signal. extSmooth - same as 'smooth' but in this mode, the DXC receives back the clock signal." ::= { prtDimCnfgEntry 5} prtDimMaxDelay OBJECT-TYPE SYNTAX INTEGER { t16msec (2), t64msec (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Max Delay permitted between the links, in msec." ::= { prtDimCnfgEntry 6} prtDimMng OBJECT-TYPE SYNTAX INTEGER { disabled (2), ts1 (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Use of DIM port for management. disabled - no management on DIM ts1 - 1 bit of TS1 is used for management." ::= { prtDimCnfgEntry 7} prtDimDestTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtDimDestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= {prtDim 2} prtDimDestEntry OBJECT-TYPE SYNTAX PrtDimDestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation is valid only for the TmpCnfg entry (prtDimDestCnfgIdx=255)." INDEX {prtDestCnfgIdx, prtDestDimIdx, prtDestIdx } ::= { prtDimDestTable 1} PrtDimDestEntry ::= SEQUENCE { prtDestCnfgIdx Integer32, prtDestDimIdx Integer32, prtDestIdx Integer32, prtDest Integer32, prtDestConnect INTEGER } prtDestCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg(1..255) being accessed. Idx of 255 relates to the TmpCnfg." ::= { prtDimDestEntry 1} prtDestDimIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number of the DIM card. The convention used for DXC: (IO slot number+10) & 1 Example: port1 of IO slot 11 will be: 211 ." ::= { prtDimDestEntry 2} prtDestIdx OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a destination number of the DIM card. " ::= { prtDimDestEntry 3} prtDest OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Destination port,(of a T1/E1 port), that is connected to the DIM card, for the specified Destination number. 0 = No destination port. Else: For external ports: (IO Slot+10) & 1 for port 1 (IO Slot+10) & 3 for port 2 Example: port2 of IO slot 12 will be: 223 . For internal ports : (IO Slot+10) & 2 for port 1 (IO Slot+10) & 4 for port 2 (IO Slot+10) & 6 for port 3 (IO Slot+10) & 8 for port 4, etc..." ::= { prtDimDestEntry 4} prtDestConnect OBJECT-TYPE SYNTAX INTEGER { no (2), yes(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Connection Status of the specified destination number. For a specified destination port, it depends both on the status of the port and on the status of the far-end port. Since this is a RO object, same value will be received for all configurations." ::= { prtDimDestEntry 5} --prtI - ISDN specific parameters table prtICnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtICnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= { prtI 1 } prtICnfgEntry OBJECT-TYPE SYNTAX PrtICnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { prtICnfgIdx, prtIIdx } ::= { prtICnfgTable 1} PrtICnfgEntry ::= SEQUENCE { prtICnfgIdx Integer32, prtIIdx Integer32, prtIRate INTEGER, prtIConnect INTEGER } prtICnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config. " ::= {prtICnfgEntry 1} prtIIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside, SP. * The ISDN B1, B2, D channels will be inside ports. For port index, see product specification." ::= {prtICnfgEntry 2} prtIRate OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), nc (2), r2bit (3), r4bit (4), r8bit (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the port rate in bits. Each TS contains 8 bits. Thus, 1 bit is equivalent to 8Kbps rate." ::= {prtICnfgEntry 3} prtIConnect OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "D channel connection. no - disconnected yes - connected. " ::= {prtICnfgEntry 4} --prtHdsl - HDSL specific parameters table prtHdslTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtHdslEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "HDSL port table." ::= { prtHdsl 1 } prtHdslEntry OBJECT-TYPE SYNTAX PrtHdslEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { prtHdslIdx } ::= { prtHdslTable 1} PrtHdslEntry ::= SEQUENCE { prtHdslIdx Integer32, prtHdslMode INTEGER, prtHdslRptrType INTEGER, prtHdslMaxRate INTEGER, prtHdslLinkType INTEGER, prtHdslCompSwVer DisplayString, prtHdslCompHwVer DisplayString } prtHdslIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside. * The HDSL ports will be external. For port index, see product specification." ::= {prtHdslEntry 1} prtHdslMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), central (2), remote (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the HDSL mode." ::= {prtHdslEntry 2} prtHdslRptrType OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), none (2), hrpt (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Repeater between Near and Far modem. none - no repeater exists between the modems hrpt - HRPT repeater exists between the modems." ::= {prtHdslEntry 3} prtHdslMaxRate OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), r192 (2), r256 (3), r320 (4), r384 (5), r448 (6), r512 (7), r576 (8), r640 (9), r768 (10), r896 (11), r1024 (12), r1152 (13), r1280 (14), r1536 (15), r1920 (16), r2048 (17) } MAX-ACCESS read-write STATUS current DESCRIPTION "Maximum Rate of the xDSL Line, in Kbps units. This object can be Set only for a Central unit." ::= {prtHdslEntry 4} prtHdslLinkType OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), msdsl2w (2), hdsl2w (3), hdsl4w (4), gDsl (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Link Type. msdsl2w - MSDSL 2 Wire hdsl2w - HDSL 2 Wire hdsl4w - HDSL 4 Wire gDsl - G.DSL " ::= {prtHdslEntry 5} prtHdslCompSwVer OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Software Version of the component (Piggyback card) supporting this interface." ::= {prtHdslEntry 6} prtHdslCompHwVer OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Hardware Version of the component (Piggyback card) supporting this interface." ::= {prtHdslEntry 7} --DACS T3/E3 port configuration parameters. Applicable also for Optimux-T3 Links. -- --These objects were entered in this private MIB, because they do not --appear in RFC1407 (except prtT3E3LineLength which appears in meters) and in --RFC-1407 MIB there is no reference to configuration number. prtT3E3CnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtT3E3CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "T3/E3 port configuration table." ::= { prtT3E3 1} prtT3E3CnfgEntry OBJECT-TYPE SYNTAX PrtT3E3CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " An entry in the T3/E3 port configuration table." INDEX { prtT3E3CnfgIdx, prtT3E3PrtIdx } ::= { prtT3E3CnfgTable 1} PrtT3E3CnfgEntry ::= SEQUENCE { prtT3E3CnfgIdx Integer32, prtT3E3PrtIdx Integer32, prtT3E3Slt INTEGER, prtT3E3LineLength INTEGER, prtT3E3InbandMng INTEGER, prtT3E3AisFrame INTEGER, prtT3E3TxClockSource INTEGER, prtT3E3RoutProt INTEGER } prtT3E3CnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config. For DXC, write operations can be performed only on the Temp Config. For products that do not support configurations, always 1 will be used." ::= { prtT3E3CnfgEntry 1} prtT3E3PrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number. For DXC: The same numbering as for prtGenPrtIdx. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside. * The external ports convention used will be (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . For Optimux-T3: Link-A: 51 Link-B: 61 . " ::= { prtT3E3CnfgEntry 2} prtT3E3Slt OBJECT-TYPE SYNTAX INTEGER { clA (3), clB (4), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), io13 (17), io14 (18), io15 (19), standAlone (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique number to identify the slot where the card is inserted in. When the unit is stand-alone, this object is not applicable and 255 will be used." ::= { prtT3E3CnfgEntry 3} prtT3E3LineLength OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), len0p450ft (2), len451p900ft (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is the length of the ds3 line in feet. It provides information for line build out circuitry if it exists and can use this object to adjust the line build out. len0p450ft = 0 - 450 feet len451p900ft = 451 - 900 feet." ::= { prtT3E3CnfgEntry 4} prtT3E3InbandMng OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), off (2), cBit (3), --Cbit-Tx-Rx cBitTxRxMng (4), cBitTx (5), cBitTxMng (6), m13 (7) } MAX-ACCESS read-write STATUS current DESCRIPTION "A unique number to identify the Frame Type over the link. For Optimux-T3: only values (4), (7) are supported." ::= {prtT3E3CnfgEntry 5} prtT3E3AisFrame OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), unframed (2), framed (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is applicable only for Optimux-T3. It allows user to select whether the AIS sent will be framed or unframed." ::= { prtT3E3CnfgEntry 6} prtT3E3TxClockSource OBJECT-TYPE SYNTAX INTEGER { external(1), -- loopTiming internal(2), -- localTiming notApplicable(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Tx Clock Source." ::= { prtT3E3CnfgEntry 7} prtT3E3RoutProt OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), none (2), proprietary (3), rip2 (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Routing Protocol of the port. This object is applicable only for T3 ports." ::= { prtT3E3CnfgEntry 8} --DACS General data, unrelated to a specific level or unit type --Compressed data table - applicable for all the MIB leafs, --Used only by NMS station cmprTable OBJECT-TYPE SYNTAX SEQUENCE OF CmprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= { genDacsMux 1 } cmprEntry OBJECT-TYPE SYNTAX CmprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {cmprTypeIdx, cmprCnfgIdx,cmprVersion,cmprSltIdx,cmprPrtIdx} ::= {cmprTable 1} CmprEntry ::= SEQUENCE { cmprTypeIdx Integer32, cmprCnfgIdx Integer32, cmprVersion Integer32, cmprSltIdx INTEGER, cmprPrtIdx Integer32, cmprObj OCTET STRING } cmprTypeIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Type of the Compressed data referred (which table, which level, etc). The type is a code according to a convention between agent and NMS." ::= { cmprEntry 1} cmprCnfgIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the configuration number the Compressed information relates to." ::= { cmprEntry 2} cmprVersion OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the version of the internal format of the Compressed data (the version of the convention used)." ::= { cmprEntry 3} cmprSltIdx OBJECT-TYPE SYNTAX INTEGER { psA (1), psB (2), clA (3), clB (4), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), io13 (17), io14 (18), io15 (19), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique number of the slot position where the card is inserted. When the unit is stand-alone or this object is not applicable, 255 will be used." ::= { cmprEntry 4} cmprPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a unique identifier of the port, the compressed information relates to. For DXC - according to the order in the card of cmprSltIdx: - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card in odd or even numbers, as follows: * For the outside/external ports, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside/internal ports, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . For FCD: see product's specification. If the port number is irrelevant to this parameter (if it is a system/card level alarm) the value will be 9999." ::= { cmprEntry 5} cmprObj OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "This object is the compressed information itself, according to a predefined format, both agent and NMS agreed about." ::= { cmprEntry 6} --mapLinkTable mapLinkTable OBJECT-TYPE SYNTAX SEQUENCE OF MapLinkEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= { genDacsMux 2} mapLinkEntry OBJECT-TYPE SYNTAX MapLinkEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {mapLinkIdx} ::= {mapLinkTable 1} MapLinkEntry ::= SEQUENCE { mapLinkIdx Integer32, mapLinkSlotIdx INTEGER, mapLinkPortIdx Integer32, mapLinkState INTEGER } mapLinkIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier of the link" ::= {mapLinkEntry 1} mapLinkSlotIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), io13 (17), io14 (18), io15 (19), standAlone (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique slot position where the module is inserted." ::= {mapLinkEntry 2} mapLinkPortIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique port number. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside, SP. In the DXC : - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card in odd or even numbers, as follows: * For the outside/external ports, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside/internal ports, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 ." ::= {mapLinkEntry 3} mapLinkState OBJECT-TYPE SYNTAX INTEGER { unknown(1), down(2), up(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the status of the link between the two muxes" ::= {mapLinkEntry 4} --Alarms List - -- -- alrGenTable OBJECT-TYPE SYNTAX SEQUENCE OF AlrGenEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= { genDacsMux 3 } alrGenEntry OBJECT-TYPE SYNTAX AlrGenEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { alrGenCode } ::= { alrGenTable 1} AlrGenEntry ::= SEQUENCE { alrGenCode Integer32, alrGenDescription DisplayString (SIZE (0..255)), alrGenLevel INTEGER, alrGenSlotType INTEGER, alrGenSeverity INTEGER, alrGenDebounce Integer32, alrGenDefSeverity INTEGER } alrGenCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object is a unique code number, identifying a certain alarm." ::= { alrGenEntry 1} alrGenDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This entry is a unique text description, of the alarm corresponding to the specified code." ::= { alrGenEntry 2} alrGenLevel OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), system (2), card (3), port (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm level." ::= {alrGenEntry 3} alrGenSlotType OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), ps (2), cl (3), io (4), clAndIo (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Slot type that the alarm is relevant to. clAndIo - an alarm that is relevant for both CL and IO slots." ::= {alrGenEntry 4} alrGenSeverity OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), event (3), minor (4), major (5), warning (6), critical (7) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object enables the user to select a severity for each alarm. The severity is set per alarm code (same for all slots/ports using this code)." ::= {alrGenEntry 5} alrGenDebounce OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "Debounce time for each alarm code, in seconds. The meaning is, that an alarm will be 'declared' as ON (or OFF), only after it was actually ON/OFF the Debouncing time selected by user. 0 = default debounce selection (each alarm has a default value). 250 = maximum value of seconds for debounce. 253 = mask = the alarm will Never be reported. 254 = default debounce selection (each alarm has a default value). 255 = not applicable " ::= {alrGenEntry 6} alrGenDefSeverity OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), event (3), minor (4), major (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object reports the default severity of each alarm. User can change the severity of the alarms defined by this default via the alrGenSeverity object." ::= {alrGenEntry 7} -- Traps --NOTIFICATIONS dacsMuxEvents OBJECT-IDENTITY STATUS current DESCRIPTION "The events for DACS MUX." ::= { dacsMux 0 } sanityCheckTrap NOTIFICATION-TYPE OBJECTS { sysSSanityCheckStatus, sysDbaseDownloadCnfgIdxCmd } STATUS current DESCRIPTION "This trap is sent after a data base download attempt. It returns the sanity result status and the configuration no.checked." ::= { dacsMuxEvents 1 } dacsMuxAlarmsTrap NOTIFICATION-TYPE STATUS current DESCRIPTION "This trap is sent when an alarm occurs." ::= { dacsMuxEvents 2 } mdlConnectTrap NOTIFICATION-TYPE OBJECTS {mdlSCardType, mdlSActivity} STATUS current DESCRIPTION "This trap is sent when a card is removed." ::= { dacsMuxEvents 3 } sysAlrStatusTrap NOTIFICATION-TYPE OBJECTS { sysSAlrStatusAll, sysSAlrStatus } STATUS current DESCRIPTION "This trap is sent upon any change in the value of any of the variables." ::= { dacsMuxEvents 4 } sysStatusChangedTrap NOTIFICATION-TYPE OBJECTS {agnLed} STATUS current DESCRIPTION "This trap is sent when Leds status is changed." ::= { dacsMuxEvents 5 } cnfgUpdateTrap NOTIFICATION-TYPE STATUS current DESCRIPTION "This trap is sent upon change of the active Configuration DB." ::= { dacsMuxEvents 6 } -- -- file :v:\doc\rdv\mib\ver470\kmux.txt -- -- RAD-KMUX MIB (Kilomux) --Title: RAD's Kilomux PRODUCT MIB --Version: 1.0 --Date: 29.8.96 --By: Yair Arian, Smadar Tauber and Yaira Gabay --File: kmux.txt -- --Last update: 20-03-2001 by Smadar Tauber kmux OBJECT IDENTIFIER ::= {radWan 6} systemKmux OBJECT IDENTIFIER ::= {kmux 1} generalKmux OBJECT IDENTIFIER ::= {systemKmux 1} sysGenKmuxTable OBJECT-TYPE SYNTAX SEQUENCE OF SysGenKmuxEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table containing the general Kmux parameters." ::= { generalKmux 1 } sysGenKmuxEntry OBJECT-TYPE SYNTAX SysGenKmuxEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {sysGenConfigIdx} ::= {sysGenKmuxTable 1} SysGenKmuxEntry ::= SEQUENCE { sysGenConfigIdx Integer32, sysGenFlipIntegration INTEGER, sysGenMlMode INTEGER, sysGenFaType INTEGER, sysGenLinkRecovery INTEGER, sysGenLinkSourceClock INTEGER, sysGenMngBwA Integer32, sysGenMngBwB Integer32, sysGenAutoDialSlot Integer32, sysGenResetBypassEnable INTEGER } sysGenConfigIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Configuration number (1..255) referred. Value of 255 specifies the TmpCnfg (Scratch). The write operation in this Table is valid only to the TmpCnfg entry." ::= { sysGenKmuxEntry 1} sysGenFlipIntegration OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), short (2), long (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The parameter is relevant only for KM-2100 and only when sysGenMlMode=redundancy, switchBackup, or priorityBumping." ::= { sysGenKmuxEntry 2} sysGenMlMode OBJECT-TYPE SYNTAX INTEGER { single (2), redundancy (3), dualLink (4), priorityBumping(5), switchBackup (6) } MAX-ACCESS read-write STATUS current DESCRIPTION "The Main Link operation mode. Determines how many links are used (one/two) and how they are used." ::= { sysGenKmuxEntry 3} sysGenFaType OBJECT-TYPE SYNTAX INTEGER { auto (2), manual (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Frame Allocation type: auto - automatic frame allocation (by Kmux) manual - manually configured frame allocation (by user)." ::= { sysGenKmuxEntry 4} sysGenLinkRecovery OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), auto (2), manual (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The parameter determines the Link Recovery mode. The parameter is relevant only when the sysGenMlMode is either switchBackup or priorityBumping." ::= { sysGenKmuxEntry 5} sysGenLinkSourceClock OBJECT-TYPE SYNTAX INTEGER { none (1), kmxMlA (103), kmxMlB (104) } MAX-ACCESS read-write STATUS current DESCRIPTION "The source clock for the links. The parameter is relevant only for KM-2100 having a KDI or KDI/CH cards. ML-A or ML-B are selectable only when sysGenMlMode=dual or priorityBumping." ::= { sysGenKmuxEntry 6} sysGenMngBwA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The required management rate for ML-A, in bps. It is very important when a remote unit is managed. The selected value must be < ML-A Rate value. 0 = None or not applicable 800 bps = minimum value 19200 bps = maximum value" ::= { sysGenKmuxEntry 7} sysGenMngBwB OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The required management rate for ML-B, in bps. It is very important when a remote unit is managed. The selected value must be < ML-B Rate value. 0 = None or not applicable 800 bps = minimum value 19200 bps = maximum value" ::= { sysGenKmuxEntry 8} sysGenAutoDialSlot OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the IO-SLOTs that can be used to initiate Automatic DialUp. This field will be applicable when KML.10 is a ML and its prtIsdnSwitchMode=auto. Each IO Slot is represented by a bit: 11 .............0 MSB(IO12) LSB(IO1) bit 0 (LSB) kmxIO1: '1'- used '0'- not used bit 1 kmxIO2: '1'- used '0'- not used bit 2 kmxIO3: '1'- used . '0'- not used . bit 11(MSB) kmxIO12: '1'- used '0'- not used The value will be: SUM of [2**n] ; n=bit number." ::= { sysGenKmuxEntry 9} sysGenResetBypassEnable OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), disabled (2), enabled (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable Reset Bypass operation when a KDI card exists and one of its links failed. notApplicable - when no KDI card exists in the Hub." ::= { sysGenKmuxEntry 10} sysGenLinkRecoveryCmd OBJECT-TYPE SYNTAX INTEGER { noOp (1), off (2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Command to recover from ML failure. When 'on', the agent will perform manual link recovery and reset the variable to 'off'. The conditions for this action are: sysGenMlMode= priorityBumping or switchBackup and also sysGenLinkRecovery=manual(3)." ::= { generalKmux 2} sysGenFlipMlCmd OBJECT-TYPE SYNTAX INTEGER { noOp (1), off (2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Command to flip the ML when sysGenMlMode=redundancy. When 'on', the agent will flip the ML and reset the variable to 'off'." ::= { generalKmux 3} sysGenMonitorChannel OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The variable specifies the channel to be monitored and presented on the front panel LEDs. The channel will be specified according to: Slot*100+Ch. 0 - no monitoring." ::= { generalKmux 4} statusKmux OBJECT IDENTIFIER ::= {systemKmux 2} sysStatusOnLineML OBJECT-TYPE SYNTAX INTEGER { both (1), kmxMlA (103), kmxMlB (104) } MAX-ACCESS read-only STATUS current DESCRIPTION "The main links which are online." ::= { statusKmux 1} sysKmuxStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A BIT string indicating the system status as follows On - the bit is set to '1': Bit 0 (LSB): Alarm Relay. Bit 1: SP param. Off- Configure the SP port from the database On - Default parameters (9600bps, 8 data bits, no parity, one stop bit). Bit 2: DBinit. The status of the dip switch in the Common Logic Card. Off- Configuration parameters were determined by the user. On - Default configuration parameters are loaded on mux power-on. Bit 3: DownloadBw. Off - Disable in-band management. On - Enable in-band management. Bit 4 (MSB): Passwd. Off - No password is required. On - Password is required. Example: 8 (10000) means Passwd.=On and all the others off." ::= { statusKmux 2} sysKmuxOffset OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), off (2), on (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "'on' - slots 1..4 of KM-2104 match slots 11..14 of KM-2100. 'off'- slots 1..4 of KM-2104 match slots 7..10 of KM-2100. notApplicable - for KM-2100." ::= { statusKmux 3} backupKmux OBJECT IDENTIFIER ::= {systemKmux 3} sysBackupTable OBJECT-TYPE SYNTAX SEQUENCE OF SysBackupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table containing the backup parameters." ::= { backupKmux 1 } sysBackupEntry OBJECT-TYPE SYNTAX SysBackupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {sysBackupConfigIdx} ::= {sysBackupTable 1} SysBackupEntry ::= SEQUENCE { sysBackupConfigIdx Integer32, sysBackupDatabase INTEGER, sysBackupMode INTEGER, sysBackupDialTimeout INTEGER, sysBackupOptions INTEGER } sysBackupConfigIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Configuration number (1..255) referred. Value of 255 specifies the TmpCnfg (Scratch)." ::= { sysBackupEntry 1} sysBackupDatabase OBJECT-TYPE SYNTAX INTEGER { onLine (2), alternate(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Determines the database to switch to, when ML recovery occurs." ::= { sysBackupEntry 2} sysBackupMode OBJECT-TYPE SYNTAX INTEGER { isdn(2), pstn(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "isdn - for connection to ISDN network. pstn - for connection to PSTN network." ::= { sysBackupEntry 3} sysBackupDialTimeout OBJECT-TYPE SYNTAX INTEGER { sec30 (2), sec45 (3), sec60 (4), sec120(5) } MAX-ACCESS read-write STATUS current DESCRIPTION "The dial timeout in seconds (when backup is attempted)." ::= { sysBackupEntry 4} sysBackupOptions OBJECT-TYPE SYNTAX INTEGER { noBackup (2), line (3), path (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The Backup options: noBackup - No backup is applicable line - Line Data backup path - Line Mng backup ." ::= { sysBackupEntry 5} sysBackupAgendaTable OBJECT-TYPE SYNTAX SEQUENCE OF SysBackupAgendaEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table containing the backup schedule. It is possible to define 4 different time zone schedules per day of the week." ::= { backupKmux 2 } sysBackupAgendaEntry OBJECT-TYPE SYNTAX SysBackupAgendaEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {sysBackupCfgIdx,sysBackupDay,sysBackupZone} ::= {sysBackupAgendaTable 1} SysBackupAgendaEntry ::= SEQUENCE { sysBackupCfgIdx INTEGER, sysBackupDay INTEGER, sysBackupZone INTEGER, sysBackupEndTime DisplayString, sysBackupStatus INTEGER } sysBackupCfgIdx OBJECT-TYPE SYNTAX INTEGER { active (1), temporary (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Configuration number (1,255) referred. Write operation for the table entries is allowed only to the temporary configuration (255)." ::= { sysBackupAgendaEntry 1} sysBackupDay OBJECT-TYPE SYNTAX INTEGER {sunday (1), monday (2), tuesday (3), wednesday(4), thursday (5), friday (6), saturday (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Day of the week." ::= { sysBackupAgendaEntry 2} sysBackupZone OBJECT-TYPE SYNTAX INTEGER {zone1(1), zone2(2), zone3(3), zone4(4), zone5(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The time zone." ::= { sysBackupAgendaEntry 3} sysBackupEndTime OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "The end time for this time zone. The format is HH:MM. For example 23:59. For Zone 4, End Time = 23:59 (constant)." ::= { sysBackupAgendaEntry 4} sysBackupStatus OBJECT-TYPE SYNTAX INTEGER { enable (1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable or disable this backup schedule entry." ::= { sysBackupAgendaEntry 5} frameAllocationKmux OBJECT IDENTIFIER ::= {systemKmux 4} sysFrameAllocationTable OBJECT-TYPE SYNTAX SEQUENCE OF SysFrameAllocationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table for manually configuring the frame allocation. The table will contain always all the programmed cards' ports. sysFaNumOfBits" ::= { frameAllocationKmux 1 } sysFrameAllocationEntry OBJECT-TYPE SYNTAX SysFrameAllocationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {sysFaConfigIdx, sysFaLink, sysFaPrt} ::= {sysFrameAllocationTable 1} SysFrameAllocationEntry ::= SEQUENCE { sysFaConfigIdx Integer32, sysFaLink INTEGER, sysFaPrt Integer32, sysFaStartingBit Integer32, sysFaNumOfBits Integer32 } sysFaConfigIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Configuration number (1..255) referred. Value of 255 specifies the TmpCnfg (Scratch). Write operation for the table entries is allowed only to Config=255." ::= { sysFrameAllocationEntry 1} sysFaLink OBJECT-TYPE SYNTAX INTEGER { kmxMlA (103), kmxMlB (104) } MAX-ACCESS read-only STATUS current DESCRIPTION "The main link on which frame allocation is done." ::= { sysFrameAllocationEntry 2} sysFaPrt OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The Frame Allocation (FA) port. The ports will be specified by: Slot*100+Ch. - for Bypass of KDI or KDI/CH the port will be: Slot*100+11 (internal-1=non-existent port ; just for use of the same MIB table) - for all the programmed cards, there will be an artificial port entry that will represent the card, in order to specify the Control Signal Bits that are at card level: Slot*100+0 . " ::= { sysFrameAllocationEntry 3} sysFaStartingBit OBJECT-TYPE SYNTAX Integer32 (0..239) MAX-ACCESS read-write STATUS current DESCRIPTION "The data starting bit for the channel. - for Bypass of KDI or KDI/CH, this will be the Starting Bit of the Bypass Window on the specific sysFaLink. - for Control Signals of a card ( sysFaPrt=Slot*100+0) this will be the Starting Bit of the Control Signals of the card." ::= { sysFrameAllocationEntry 4} sysFaNumOfBits OBJECT-TYPE SYNTAX Integer32 (0..239) MAX-ACCESS read-write STATUS current DESCRIPTION "The data size in number of bits for the channel. - for Bypass of KDI or KDI/CH, this will be the Bypass Window size. In this case, this value must be the same for both MLs. - for Control Signals of a card ( sysFaPrt=Slot*100+0) this will be the number of Control Signal Bits of the card." ::= { sysFrameAllocationEntry 5} -- Disconnect Supervision Event Table. -- This table contains all the Disconnect Supervision Events -- that occurred on the KVF.6 and KVF.8 cards of the KM. sysDisconnectSupervisionEventTable OBJECT-TYPE SYNTAX SEQUENCE OF SysDisconnectSupervisionEventEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Disconnect Supervision Event table." ::= {systemKmux 5} sysDisconnectSupervisionEventEntry OBJECT-TYPE SYNTAX SysDisconnectSupervisionEventEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table." INDEX { sysDsEventIdx } ::= { sysDisconnectSupervisionEventTable 1} SysDisconnectSupervisionEventEntry ::= SEQUENCE { sysDsEventIdx Integer32, sysDsEventSlot INTEGER, sysDsEventTS Integer32, sysDsEventDescr DisplayString, sysDsEventDateAndTime DisplayString } sysDsEventIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a unique Event Index." ::= { sysDisconnectSupervisionEventEntry 1} sysDsEventSlot OBJECT-TYPE SYNTAX INTEGER { kmxIO1 (107), kmxIO2 (108), kmxIO3 (109), kmxIO4 (110), kmxIO5 (111), kmxIO6 (112), kmxIO7 (113), kmxIO8 (114), kmxIO9 (115), kmxIO10(116), kmxIO11(117), kmxIO12(118) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a unique number of the slot position, where the KVF.6 or KVF.8 card is inserted, and the Disconnect Supervision Event occurred." ::= { sysDisconnectSupervisionEventEntry 2} sysDsEventTS OBJECT-TYPE SYNTAX Integer32 (1..31) MAX-ACCESS read-only STATUS current DESCRIPTION "This object defines the Time Slot number, where the Disconnect Supervision Event occurred." ::= { sysDisconnectSupervisionEventEntry 3} sysDsEventDescr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object defines the Description of the Disconnect Supervision Event." ::= { sysDisconnectSupervisionEventEntry 4} sysDsEventDateAndTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object defines the Date and Time, when the Disconnect Supervision Event occurred. It will be displayed in the following format: YYYY-MM-DD HH:MM:SS." ::= { sysDisconnectSupervisionEventEntry 5} mdlKmux OBJECT IDENTIFIER ::= {kmux 2} mdlKmxTable OBJECT-TYPE SYNTAX SEQUENCE OF MdlKmxEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= { mdlKmux 2 } mdlKmxEntry OBJECT-TYPE SYNTAX MdlKmxEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { mdlKmxConfigIdx, mdlKmxSlotIdx } ::= { mdlKmxTable 1} MdlKmxEntry ::= SEQUENCE { mdlKmxConfigIdx Integer32, mdlKmxSlotIdx INTEGER, mdlKmxOperatedMl INTEGER, mdlKmxMlAtoMlBPrio INTEGER, mdlKmxMlBtoMlAPrio INTEGER, mdlKmxOutSrvMethod INTEGER, mdlKmxV54Config INTEGER, mdlKmxTiming INTEGER } mdlKmxConfigIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Configuration number (1..255) referred. Value of 255 specifies the TmpCnfg (Scratch). Write operation for the table entries is allowed only to Config=255." ::= { mdlKmxEntry 1} mdlKmxSlotIdx OBJECT-TYPE SYNTAX INTEGER { kmxPsA (101), kmxPsB (102), kmxMlA (103), kmxMlB (104), kmxCl (105), kmxOpt (106), kmxIO1 (107), kmxIO2 (108), kmxIO3 (109), kmxIO4 (110), kmxIO5 (111), kmxIO6 (112), kmxIO7 (113), kmxIO8 (114), kmxIO9 (115), kmxIO10(116), kmxIO11(117), kmxIO12(118) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a unique number of the slot position in which the module is inserted." ::= { mdlKmxEntry 2} mdlKmxOperatedMl OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), kmxMlA (103), kmxMlB (104), kmxMlAandMlB (119) -- for KVF.6 and KMBE/NEW } MAX-ACCESS read-write STATUS current DESCRIPTION "The main link for this card. The field is relevant only for ML modes of Dual, Priority Bumping and Switched Backup." ::= { mdlKmxEntry 3} mdlKmxMlAtoMlBPrio OBJECT-TYPE SYNTAX INTEGER {notApplicable(1), low (2), high (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "ML-A to ML-B Priority. The field is relevant only for ML modes of Priority Bumping and Switched Backup." ::= { mdlKmxEntry 4} mdlKmxMlBtoMlAPrio OBJECT-TYPE SYNTAX INTEGER {notApplicable(1), low (2), high (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "ML-B to ML-A Priority. The field is relevant only for ML modes of Priority Bumping." ::= { mdlKmxEntry 5} mdlKmxOutSrvMethod OBJECT-TYPE SYNTAX INTEGER {notApplicable(1), idleBusy (2), forcedIdle (3), busyIdle (4), forcedBusy (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Out of service method. For KVC.1 and KVC.1M all values are applicable. For KVC.2, KVC.3, KVF.1, KVF.3, KVF.4: only forcedIdle and forcedBusy are applicable." ::= { mdlKmxEntry 6} mdlKmxV54Config OBJECT-TYPE SYNTAX INTEGER {notApplicable(1), dceDce (2), dceDte (3), dteDce (4), dteDte (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Relevant only for KLS.1/New card." ::= { mdlKmxEntry 7} mdlKmxTiming OBJECT-TYPE SYNTAX INTEGER {notApplicable(1), lt (2), nt (3), te (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable only for KHSU.1, KHSU.2, KVF.4/S0, KVC.3/S0 cards. lt - local timing nt - network timing te - terminal equipment " ::= { mdlKmxEntry 8} mdlKvf5PbxTable OBJECT-TYPE SYNTAX SEQUENCE OF MdlKvf5PbxEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Parameters specific to KVF.5, KVF.6 and KVF.8 PBX cards." ::= { mdlKmux 3 } mdlKvf5PbxEntry OBJECT-TYPE SYNTAX MdlKvf5PbxEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { mdlKvf5PbxConfigIdx, mdlKvf5PbxSlotIdx } ::= { mdlKvf5PbxTable 1} MdlKvf5PbxEntry ::= SEQUENCE { mdlKvf5PbxConfigIdx Integer32, mdlKvf5PbxSlotIdx INTEGER, mdlKvf5PbxSig INTEGER, mdlKvf5PbxSigMode INTEGER, mdlKvf5PbxTsAssign INTEGER, mdlKvf5PbxCcsTs Integer32, mdlKvf5PbxOos INTEGER, mdlKvf5PbxSigTxPbx INTEGER, mdlKvf5PbxSigRxPbx INTEGER, mdlKvf5PbxDefABCD OCTET STRING, mdlKvf5PbxFramerSlot INTEGER, mdlKvf5PbxCcsRate INTEGER, mdlKvf5PbxTxAbcdBit OCTET STRING, mdlKvf5PbxHdlcCrc INTEGER } mdlKvf5PbxConfigIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Configuration number (1..255) referred. Value of 255 specifies the TmpCnfg (Scratch). Write operation for the table entries is allowed only to Config=255." ::= { mdlKvf5PbxEntry 1} mdlKvf5PbxSlotIdx OBJECT-TYPE SYNTAX INTEGER { kmxIO1 (107), kmxIO2 (108), kmxIO3 (109), kmxIO4 (110), kmxIO5 (111), kmxIO6 (112), kmxIO7 (113), kmxIO8 (114), kmxIO9 (115), kmxIO10(116), kmxIO11(117), kmxIO12(118) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a unique number of the slot position in which the module is inserted." ::= { mdlKvf5PbxEntry 2} mdlKvf5PbxSig OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), a (2), aANDb(3), b (4), ccs (5), cas (6) } MAX-ACCESS read-write STATUS current DESCRIPTION "Signaling type. When 'mdlKvf5PbxSig' is valid, 'mdlKvf5PbxSigTxPbx' and 'mdlKvf5PbxSigRxPbx' are not valid. mdlKvf5PbxSig - is supported by KVF.5 OLD SW ver and KVF.6 card. mdlKvf5PbxSigTxPbx and mdlKvf5PbxSigRxPbx - are supported by KVF.5 NEW SW ver and KVF.6." ::= { mdlKvf5PbxEntry 3} mdlKvf5PbxSigMode OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), direct (2), inverse(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Signaling Mode." ::= { mdlKvf5PbxEntry 4} mdlKvf5PbxTsAssign OBJECT-TYPE SYNTAX INTEGER { s1s2s3s4 (2), s5s6s7s8 (3), s9s10s11s12 (4), s13s14s15s16 (5), s17s18s19s20 (6), s21s22s23s24 (7), s13s14s15s17 (8), s18s19s20s21 (9), s22s23s24s25(10), s26s27s28s29(11), s30s31 (12) } MAX-ACCESS read-write STATUS current DESCRIPTION "Ts Assignment group. Each KVF.5 card of the Mux should have a different value. For KVF.5/E1 values: 2,3,4,8,9,10,11,12 are applicable. For KVF.5/T1 values: 2,3,4,5,6,7 are applicable." ::= { mdlKvf5PbxEntry 5} mdlKvf5PbxCcsTs OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "CCS TS of the KVF.5/T1/E1 and KVF.6/T1/E1 card. It is applicable for Kmux KVF.5 Framer cards and KVF.6 cards when mdlKvf5PbxSig=ccs. Valid values: 1..24 - CCS TS of T1 1..31 - CCS TS of E1 255 - notApplicable (for agents that do not support this feature or for irrelevant cards) Other values are invalid. The value selected should not be the same as one of the TSs assigned for any card of the same group via mdlKvf5PbxTsAssign." ::= { mdlKvf5PbxEntry 6} mdlKvf5PbxOos OBJECT-TYPE SYNTAX INTEGER { notSupported (2), forcedIdle (3), forcedBusy (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "'idle' = '0' = on-hook, idle state 'busy' = '1' = off-hook, busy state 'forcedIdle' = SP = both A and B signaling bits are forced to '0' during out-of-service periods. 'forcedBusy' = MK = both A and B signaling bits are forced to '1' during out-of-service periods. - for T1: '0'=0 ; '1'=1 - for E1: '0'=1 ; '1'=0 " ::= { mdlKvf5PbxEntry 7} mdlKvf5PbxSigTxPbx OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), a (2), b (3), aANDb (4), crossAandB (5), ccs (6), aEqualsB (7) } MAX-ACCESS read-write STATUS current DESCRIPTION "TxPbx signaling means transmit signaling from KM to PBX (KM-->PBX) When 'mdlKvf5PbxSigTxPbx' is valid, 'mdlKvf5PbxSig' field is not valid. mdlKvf5PbxSig - is supported by KVF.5 OLD SW ver. mdlKvf5PbxSigTxPbx and mdlKvf5PbxSigRxPbx - are supported by KVF.5 NEW SW ver." ::= { mdlKvf5PbxEntry 8} mdlKvf5PbxSigRxPbx OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), a (2), b (3), aANDb (4), ccs (6) } MAX-ACCESS read-write STATUS current DESCRIPTION "RxPbx signaling means receive signaling from PBX to KM (PBX-->KM-->KM) When 'mdlKvf5PbxSigRxPbx' is valid, 'mdlKvf5PbxSig' field is not valid. mdlKvf5PbxSig - is supported by KVF.5 OLD SW ver. mdlKvf5PbxSigTxPbx and mdlKvf5PbxSigRxPbx - are supported by KVF.5 NEW SW ver." ::= { mdlKvf5PbxEntry 9} mdlKvf5PbxDefABCD OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..1)) MAX-ACCESS read-write STATUS current DESCRIPTION "This object determines what KM will send for the ABCD Bits that are not 'filled' by the dynamic signaling. This field is applicable only for signaling transmit to PBX ('mdlKvf5PbxSigTxPbx'). For KVF.5 cards: valid range (00 - 0F HEX) - ABCD Bits." ::= { mdlKvf5PbxEntry 10} mdlKvf5PbxFramerSlot OBJECT-TYPE SYNTAX INTEGER { kmxIO1 (107), kmxIO2 (108), kmxIO3 (109), kmxIO4 (110), kmxIO5 (111), kmxIO6 (112), kmxIO7 (113), kmxIO8 (114), kmxIO9 (115), kmxIO10(116), kmxIO11(117), kmxIO12(118), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the Framer's slot number this card belongs to. Several cards having the same mdlKvf5PbxFramerSlot value, work together as a group." ::= { mdlKvf5PbxEntry 11} mdlKvf5PbxCcsRate OBJECT-TYPE SYNTAX INTEGER { notConnected(1), bps4800(2), bps6400(3), bps9600(4), bps12800(5), bps16000(6), bps19200(7), bps32000(8), bps64000(9) } MAX-ACCESS read-write STATUS current DESCRIPTION "Determines the Ccs speed - for KVF.6 and KVF.5 cards." ::= { mdlKvf5PbxEntry 12} mdlKvf5PbxTxAbcdBit OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "This object is applicable only for KVF.6 and KVF.8 cards, when mdlKvf5PbxSig=cas(6). It represents 4 parameters, by 2 Octets : D Bit Code-MSB nibble, C Bit Code- nibble, B Bit Code- nibble, A Bit Code-LSB nibble. Each of A,B,C,D Bit Code nibble represents: 0 hex = 0000 = 0 1 hex = 0001 = 1 2 hex = 0010 = A bit 3 hex = 0011 = B bit 4 hex = 0100 = C bit 5 hex = 0101 = D bit 6 hex = 0110 = A bit inverse 7 hex = 0111 = B bit inverse 8 hex = 1000 = C bit inverse 9 hex = 1001 = D bit inverse A-E hex - not used (invalid values) When the object is not applicable, 0 Octets will be sent." ::= { mdlKvf5PbxEntry 13} mdlKvf5PbxHdlcCrc OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), crc16(2), crc32(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Determines the CRC type of HDLC protocol, that CCS signaling is working with. Applicable for KVF.6 cards when Signaling is CCS (only)." ::= { mdlKvf5PbxEntry 14} -- Disconnect Supervision (Ds) Table. -- Applicable for KVF.6 and KVF.8 cards. mdlDisconnectSupervisionTable OBJECT-TYPE SYNTAX SEQUENCE OF MdlDisconnectSupervisionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Disconnect Supervision table." ::= { mdlKmux 4 } mdlDisconnectSupervisionEntry OBJECT-TYPE SYNTAX MdlDisconnectSupervisionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table." INDEX { mdlDsConfigIdx, mdlDsSlotIdx } ::= { mdlDisconnectSupervisionTable 1} MdlDisconnectSupervisionEntry ::= SEQUENCE { mdlDsConfigIdx Integer32, mdlDsSlotIdx INTEGER, mdlDs INTEGER, mdlDsUserLoc INTEGER, mdlDsMode INTEGER, mdlDsSilence Integer32, mdlDsClrFwSig OCTET STRING, mdlDsAnswerSig OCTET STRING, mdlDsClrBwSig OCTET STRING, mdlDsFbtLowFreq Integer32, mdlDsFbtHighFreq Integer32, mdlDsFbtTimeOn1 Integer32, mdlDsFbtTimeOff1 Integer32, mdlDsFbtTimeOn2 Integer32, mdlDsFbtTimeOff2 Integer32, mdlDsFbtLowFreqLevel Integer32, mdlDsFbtHighFreqLevel Integer32 } mdlDsConfigIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Configuration number (1..255) referred. Value of 255 specifies the TmpCnfg (Scratch). Write operation for the table entries is allowed only to Config=255." ::= { mdlDisconnectSupervisionEntry 1} mdlDsSlotIdx OBJECT-TYPE SYNTAX INTEGER { kmxIO1 (107), kmxIO2 (108), kmxIO3 (109), kmxIO4 (110), kmxIO5 (111), kmxIO6 (112), kmxIO7 (113), kmxIO8 (114), kmxIO9 (115), kmxIO10(116), kmxIO11(117), kmxIO12(118) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a unique number of the slot position in which the module is inserted." ::= { mdlDisconnectSupervisionEntry 2} mdlDs OBJECT-TYPE SYNTAX INTEGER { disable (1), remoteDisconnect (2), remoteDisconnectAndSilence (3), silenceOnly (4), fastBusyOnly (5), silenceOrFastBusy (6) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object defines which terms will cause disconnection of call. disable = the Disconnect Supervision feature is disabled. In this case, all other objects of this table are irrelevant. Remote Sanity - If mdlDsUserLoc = Remote Location , the valid values are : disable(1), silenceOnly(4), fastBusyOnly(5), silenceOrFastBusy(6). If mdlDsUserLoc = Local , the valid values are disable(1), remoteDisconnect(2), remoteDisconnectAndSilence (3)." ::= { mdlDisconnectSupervisionEntry 3} mdlDsUserLoc OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), remote (2), local (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "User located in local or remote station. Local station will disconnect the call actually if needed. Applicable only if Disconnect Supervision (mdlDs) is different from disable. Should be a Sanity check between the mdlDs and the mdlDsUserLoc parameters (see mdlDs)." ::= { mdlDisconnectSupervisionEntry 4} mdlDsMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), reportOnly (2), disconnect (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object defines the action, which will be done after remote disconnect occurred. This object is relevant only when mdlDsUserLoc = local(3). Applicable only if Disconnect Supervision (mdlDs) is different from disable AND User Location (mdlDsUserLoc) = local(3)." ::= { mdlDisconnectSupervisionEntry 5} mdlDsSilence OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object defines the silence period needed for an indication (seconds). Applicable only if Disconnect Supervision (mdlDs) is different from disable AND includes 'Silence', i.e. is one of the following: remoteDisconnectAndSilence(3), silenceOnly(4), silenceOrFastBusy(6). Valid values: 0,20,40..(every 20 seconds)..300, 0 = notApplicable. notApplicable = silence disabled when mdlDs doesn't include 'silence'." ::= { mdlDisconnectSupervisionEntry 6} mdlDsClrFwSig OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "This object defines the Clear FWD Signal (A,B,C,D bits) for KVF.6 cards. This object is an indication of Near PBX to the Far PBX, that it wants to disconnect the call. Applicable only if Disconnect Supervision (mdlDs) is different from disable. Applicable only for KVF.6 cards. It represents 4 parameters, by an Octet: ( Bit 7 = MSB, Bit 0 = LSB ) D Bit - bits 6,7 of the MSB nibble, C Bit - bits 4,5 of the MSB nibble, B Bit - bits 2,3 of the LSB nibble, A Bit - bits 0,1 of the LSB nibble. For each of A,B,C,D Bits: 00 = 0, 01 = 1, 10 = reserved, 11 = x. For A,B Bits - only one of them can be 'x' (not both at the same time). For C,D Bits - 'x' won't be in use. When the object is not applicable, a 0 Octet will be sent." ::= { mdlDisconnectSupervisionEntry 7} mdlDsAnswerSig OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "This object defines the Clear FWD Signal (A,B,C,D bits) for KVF.6 cards. This object is an indication of Near PBX to the Far PBX, taht a call is present now on the line. Applicable only if Disconnect Supervision (mdlDs) is different from disable. Applicable only for KVF.6 cards. It represents 4 parameters, by an Octet: ( Bit 7 = MSB, Bit 0 = LSB ) D Bit - bits 6,7 of the MSB nibble, C Bit - bits 4,5 of the MSB nibble, B Bit - bits 2,3 of the LSB nibble, A Bit - bits 0,1 of the LSB nibble. For each of A,B,C,D Bits: 00 = 0, 01 = 1, 10 = reserved, 11 = x. For A,B Bits - only one of them can be 'x' (not both at the same time). For C,D Bits - 'x' won't be in use. When the object is not applicable, a 0 Octet will be sent." ::= { mdlDisconnectSupervisionEntry 8} mdlDsClrBwSig OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "This object defines the Clear FWD Signal (A,B,C,D bits) for KVF.6 cards. This object is an indication of Far PBX to the Near PBX, that the call was disconnected (on the Far side). Applicable only if Disconnect Supervision (mdlDs) is different from disable. Applicable only for KVF.6 cards. It represents 4 parameters, by an Octet: ( Bit 7 = MSB, Bit 0 = LSB ) D Bit - bits 6,7 of the MSB nibble, C Bit - bits 4,5 of the MSB nibble, B Bit - bits 2,3 of the LSB nibble, A Bit - bits 0,1 of the LSB nibble. For each of A,B,C,D Bits: 00 = 0, 01 = 1, 10 = reserved, 11 = x. For A,B,C,D Bits - 'x' won't be in use. When the object is not applicable, a 0 Octet will be sent." ::= { mdlDisconnectSupervisionEntry 9} mdlDsFbtLowFreq OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "First frequency in Fast Busy Tone (Fbt) combination (Hz). Valid values: 0..4000,4095. 4095 = notApplicable. Available only if Disconnect Supervision (mdlDs) is different from disable AND includes 'Tones' (Fast Busy), i.e. is one of the following: fastBusyOnly(5), silenceOrFastBusy(6)." ::= { mdlDisconnectSupervisionEntry 10} mdlDsFbtHighFreq OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Second frequency in Fast Busy Tone (Fbt) combination (Hz). Valid values: 0..4000,4095. 4095 = notApplicable. Available only if Disconnect Supervision (mdlDs) is different from disable AND includes 'Tones' (Fast Busy), i.e. is one of the following: fastBusyOnly(5), silenceOrFastBusy(6)." ::= { mdlDisconnectSupervisionEntry 11} mdlDsFbtTimeOn1 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object defines the Time On 1 cadence (in msec). Valid values: 0,10,20..(every 10 msec)..10000,10230. 0 = disable, 10230 = notApplicable. Available only if Disconnect Supervision (mdlDs) is different from disable AND includes 'Tones' (Fast Busy), i.e. is one of the following: fastBusyOnly(5), silenceOrFastBusy(6)." ::= { mdlDisconnectSupervisionEntry 12} mdlDsFbtTimeOff1 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object defines the Time Off 1 cadence (in msec). Valid values: 0,10,20..(every 10 msec)..10000,10230. 0 = disable, 10230 = notApplicable. Available only if Disconnect Supervision (mdlDs) is different from disable AND includes 'Tones' (Fast Busy), i.e. is one of the following: fastBusyOnly(5), silenceOrFastBusy(6)." ::= { mdlDisconnectSupervisionEntry 13} mdlDsFbtTimeOn2 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object defines the Time On 2 cadence (in msec). Valid values: 0,10,20..(every 10 msec)..10000,10230. 0 = disable, 10230 = notApplicable. Available only if Disconnect Supervision (mdlDs) is different from disable AND includes 'Tones' (Fast Busy), i.e. is one of the following: fastBusyOnly(5), silenceOrFastBusy(6)." ::= { mdlDisconnectSupervisionEntry 14} mdlDsFbtTimeOff2 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object defines the Time Off 2 cadence (in msec). Valid values: 0,10,20..(every 10 msec)..10000,10230. 0 = disable, 10230 = notApplicable. Available only if Disconnect Supervision (mdlDs) is different from disable AND includes 'Tones' (Fast Busy), i.e. is one of the following: fastBusyOnly(5), silenceOrFastBusy(6)." ::= { mdlDisconnectSupervisionEntry 15} mdlDsFbtLowFreqLevel OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "First frequency level for Fast Busy Tone (Fbt) in dBm units. Valid values: -32..31. Available only if Disconnect Supervision (mdlDs) is different from disable AND includes 'Tones' (Fast Busy), i.e. is one of the following: fastBusyOnly(5), silenceOrFastBusy(6)." ::= { mdlDisconnectSupervisionEntry 16} mdlDsFbtHighFreqLevel OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Second frequency level for Fast Busy Tone (Fbt) in dBm units. Valid values: -32..31. Available only if Disconnect Supervision (mdlDs) is different from disable AND includes 'Tones' (Fast Busy), i.e. is one of the following: fastBusyOnly(5), silenceOrFastBusy(6)." ::= { mdlDisconnectSupervisionEntry 17} prtKmux OBJECT IDENTIFIER ::= {kmux 3} prtMainLink OBJECT IDENTIFIER ::= {prtKmux 1} prtMlFrameStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtMlFrameStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Frame diagnostics for the main links." ::= { prtMainLink 1 } prtMlFrameStatsEntry OBJECT-TYPE SYNTAX PrtMlFrameStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { prtMlFrameIdx } ::= { prtMlFrameStatsTable 1} PrtMlFrameStatsEntry ::= SEQUENCE { prtMlFrameIdx Integer32, prtMlFrameSlt INTEGER, prtMlBitWeight INTEGER, prtMlDataUsage Integer32, prtMlControlSig Integer32, prtMlDownload Integer32, prtMlSync Integer32, prtMlTotalUsage Integer32, prtMlTotalFree Integer32 } prtMlFrameIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The prtGenPrtIdx index of this link. Slot*100+1." ::= { prtMlFrameStatsEntry 1} prtMlFrameSlt OBJECT-TYPE SYNTAX INTEGER { kmxMlA (103), kmxMlB (104) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique number to identify the slot where the ML card is inserted." ::= { prtMlFrameStatsEntry 2} prtMlBitWeight OBJECT-TYPE SYNTAX INTEGER { bps400 (1), bps800 (2), bps1600 (3), bps3200 (4), bps6400 (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Bit Weight [bps/bit] used for the selected prtMlFrameSlt. The Bit Weight is according to the ML Speed." ::= { prtMlFrameStatsEntry 3} prtMlDataUsage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Data usage in [bits]. In order to convert it to 'bps' units, the 'bits' should be multiplied by prtMlBitWeight value." ::= { prtMlFrameStatsEntry 4} prtMlControlSig OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Control Signals usage of the ML in [bits]. In order to convert it to 'bps' units, the 'bits' should be multiplied by prtMlBitWeight value." ::= { prtMlFrameStatsEntry 5} prtMlDownload OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Download bandwidth usage of the ML in [bits]. In order to convert it to 'bps' units, the 'bits' should be multiplied by prtMlBitWeight value." ::= { prtMlFrameStatsEntry 6} prtMlSync OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Sync bandwidth usage of the ML in [bits]. In order to convert it to 'bps' units, the 'bits' should be multiplied by prtMlBitWeight value." ::= { prtMlFrameStatsEntry 7} prtMlTotalUsage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total bandwidth usage of the ML in [bits]. In order to convert it to 'bps' units, the 'bits' should be multiplied by prtMlBitWeight value." ::= { prtMlFrameStatsEntry 8} prtMlTotalFree OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Free bandwidth of the ML in [bits]. In order to convert it to 'bps' units, the 'bits' should be multiplied by prtMlBitWeight value." ::= { prtMlFrameStatsEntry 9} prtMlTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtMlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Parameters for the main links. KML.1 - KML.6, KML.7(T1), KML.8(E1), KML.10(ISDN) and KML.F(KML.11 Fiber-optic)." ::= { prtMainLink 2 } prtMlEntry OBJECT-TYPE SYNTAX PrtMlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { prtMlCnfgIdx, prtMlIdx } ::= { prtMlTable 1} PrtMlEntry ::= SEQUENCE { prtMlCnfgIdx Integer32, prtMlIdx Integer32, prtMlSlt INTEGER, prtMlTiming INTEGER, prtMlBufferSize INTEGER, prtMlDsrCts INTEGER, prtMlSpeed INTEGER, prtMlStartTS Integer32, prtMlBypassTs16 INTEGER, prtMlCallMode INTEGER, prtMlBondingEnable INTEGER } prtMlCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config. Write operation for the table entries is allowed only to Config=255. " ::= { prtMlEntry 1} prtMlIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The prtGenPrtIdx index of this link. Slot*100+1 ." ::= { prtMlEntry 2} prtMlSlt OBJECT-TYPE SYNTAX INTEGER { kmxMlA (103), kmxMlB (104) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique number to identify the slot where the ML card is inserted in." ::= { prtMlEntry 3} prtMlTiming OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), dte (2), dce (3), eDce (4), int (5), lbt (6), adaptive (7) } MAX-ACCESS read-write STATUS current DESCRIPTION "The clock source for this link. For KML.1-KML.4, valid values: dte, eDce, or dce. For KML.5-KML.8, valid values: int or lbt. notApplicable - for KML.10 and KML.F." ::= { prtMlEntry 4} prtMlBufferSize OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), bits8 (2), bits256 (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The buffer size in bits for absorbing timing jitters." ::= { prtMlEntry 5} prtMlDsrCts OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), internal (2), external (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Determines the DSR and CTS signal handling. notApplicable - for KML.4-KML.6." ::= { prtMlEntry 6} prtMlSpeed OBJECT-TYPE SYNTAX INTEGER { bps9600(2), bps14400(3), bps19200(4), bps28800(5), bps32000(6), bps48000(7), bps56000(8), bps64000(9), bps128000(10), bps192000(11), bps256000(12), bps384000(13), bps512000(14), bps768000(15), bps1024000(16), bps1536000(17) } MAX-ACCESS read-write STATUS current DESCRIPTION "Determines the Main Link port speed. KML.1, KML.3, KML.4 support (Kbps): 9.6, 14.4, 19.2, 28.8, 32, 48, 56, 64, 128, 192, 256, 384, 512, 768, 1024, 1536. KML.2 supports (Kbps): 9.6, 14.4, 19.2, 28.8, 32, 48, 56, 64, 128 KML.5 supports (Kbps): 64, 128. KML.6 supports (Kbps): 9.6, 19.2, 56. KML.7-KML.8 support (Kbps): 56, 64, 128, 192, 256, 384, 512, 768, 1024, 1536. KML.10 supports (Kbps): 64, 128. KML.F supports (Kbps): 128, 256, 384, 512, 768, 1024, 1536." ::= { prtMlEntry 7} prtMlStartTS OBJECT-TYPE SYNTAX Integer32 (0..31) MAX-ACCESS read-write STATUS current DESCRIPTION "0=notApplicable - for all cards except KML.7, KML.8 For KML.7 - valid values: 1..24 For KML.8 - valid values: 1..31." ::= { prtMlEntry 8} prtMlBypassTs16 OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "notApplicable - for all cards except KML.8." ::= { prtMlEntry 9} prtMlCallMode OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), initiate (2), listen (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object will be used when using an external modem linked to the KML.1-KML.4 or KML.10 cards. Initiate - KML card can initiate calls to the modem Listen - KML card listens only ; cannot initiate a call." ::= { prtMlEntry 10} prtMlBondingEnable OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), disabled (2), enabled (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Disable/Enable applying the Bonding process, for KML.10 cards. notApplicable - for all cards except KML.10." ::= { prtMlEntry 11} prtMlIsdnTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtMlIsdnEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Parameters for ISDN main links: KML.10." ::= { prtMainLink 3 } prtMlIsdnEntry OBJECT-TYPE SYNTAX PrtMlIsdnEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { prtMlIsdnCnfgIdx, prtMlIsdnIdx } ::= { prtMlIsdnTable 1} PrtMlIsdnEntry ::= SEQUENCE { prtMlIsdnCnfgIdx Integer32, prtMlIsdnIdx Integer32, prtMlIsdnSlt INTEGER, prtMlIsdnMode INTEGER, prtMlIsdnStandard INTEGER, prtMlIsdnLocSubNum DisplayString, prtMlIsdnLocNum DisplayString, prtMlIsdnOutSubNum DisplayString, prtMlIsdnBackupCallNum DisplayString, prtMlIsdnInNumMode INTEGER } prtMlIsdnCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config. Write operation for the table entries is allowed only to Config=255. " ::= { prtMlIsdnEntry 1} prtMlIsdnIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The prtGenPrtIdx index of this link. Slot*100+1 ." ::= { prtMlIsdnEntry 2} prtMlIsdnSlt OBJECT-TYPE SYNTAX INTEGER { kmxMlA (103), kmxMlB (104) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique number to identify the slot where the ML card is inserted in." ::= { prtMlIsdnEntry 3} prtMlIsdnMode OBJECT-TYPE SYNTAX INTEGER { leased (2), switched(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "ISDN Mode. switched - when ML Mode is Switched Backup. leased - in all other cases." ::= { prtMlIsdnEntry 4} prtMlIsdnStandard OBJECT-TYPE SYNTAX INTEGER { european (2), israeli (3), ess5Multipoint(4), ess5Ptp (5), dms100 (6), ntt (7), nationalIsdn1 (8) } MAX-ACCESS read-write STATUS current DESCRIPTION "The ISDN standard." ::= { prtMlIsdnEntry 5} prtMlIsdnLocSubNum OBJECT-TYPE SYNTAX DisplayString (SIZE(0..25)) MAX-ACCESS read-write STATUS current DESCRIPTION "Local sub-number. 4 chars (digits 0..9)." ::= { prtMlIsdnEntry 6} prtMlIsdnLocNum OBJECT-TYPE SYNTAX DisplayString (SIZE(0..25)) MAX-ACCESS read-write STATUS current DESCRIPTION "Local number. 20 chars (digits: 0..9)." ::= { prtMlIsdnEntry 7} prtMlIsdnOutSubNum OBJECT-TYPE SYNTAX DisplayString (SIZE(0..25)) MAX-ACCESS read-write STATUS current DESCRIPTION "Out sub-number. 4 chars (digits 0..9)." ::= { prtMlIsdnEntry 8} prtMlIsdnBackupCallNum OBJECT-TYPE SYNTAX DisplayString (SIZE(0..25)) MAX-ACCESS read-write STATUS current DESCRIPTION "Backup call number. 20 chars (digits: 0..9)." ::= { prtMlIsdnEntry 9} prtMlIsdnInNumMode OBJECT-TYPE SYNTAX INTEGER { none (2), all (3), local(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "In number mode." ::= { prtMlIsdnEntry 10} prtHsLs OBJECT IDENTIFIER ::= {prtKmux 2} prtHsLsTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtHsLsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Parameters for the High and Low speed channels. Cards: KLS.1,KLS.2, KHS.1, KHS.2, KDI/CH, KHSU.1, KHSU.2, KHS.703." ::= { prtHsLs 1 } prtHsLsEntry OBJECT-TYPE SYNTAX PrtHsLsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { prtHsLsCnfgIdx, prtHsLsIdx } ::= { prtHsLsTable 1} PrtHsLsEntry ::= SEQUENCE { prtHsLsCnfgIdx Integer32, prtHsLsIdx Integer32, prtHsLsSlt INTEGER, prtHsLsCommProtocol INTEGER, prtHsLsAsyncDataLen INTEGER, prtHsLsTiming INTEGER, prtHsLsCtrlSignal INTEGER, prtHsLsCts INTEGER, prtHsLsRtsCtsDelay INTEGER, prtHsLsDsrMode INTEGER, prtHsLsSpeed INTEGER, prtHsLsUType INTEGER } prtHsLsCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config. Write operation for the table entries is allowed only to Config=255. " ::= { prtHsLsEntry 1} prtHsLsIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The prtGenPrtIdx index of this channel. In KHSU.1 and KHSU.2 there are three ISDN sub-channels on each port (2B+D).The sub-channels are numbered: Slot*100+11 ; Slot*100+12 ; Slot*100+13 (First Port), Slot*100+14 ; Slot*100+15 ; Slot*100+16 (Second Port)." ::= { prtHsLsEntry 2} prtHsLsSlt OBJECT-TYPE SYNTAX INTEGER { kmxOpt (106), -- For KDI/CH card type kmxIO1 (107), kmxIO2 (108), kmxIO3 (109), kmxIO4 (110), kmxIO5 (111), kmxIO6 (112), kmxIO7 (113), kmxIO8 (114), kmxIO9 (115), kmxIO10(116), kmxIO11(117), kmxIO12(118) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique number to identify the slot where the card is inserted in. In the 2104 Unit the entries kmxIO5(111)..kmxIO12(118) are not valid. The entry kmxOpt(106) is valid only for KDI/CH card." ::= { prtHsLsEntry 3} prtHsLsCommProtocol OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), async (2), sync (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The communication protocol." ::= { prtHsLsEntry 4} prtHsLsAsyncDataLen OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), bit6 (2), bit7 (3), bit8 (4), bit9 (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Async Data Length in Bits. notApplicable - when prtHsLsCommProtocol=sync or notApplicable." ::= { prtHsLsEntry 5} prtHsLsTiming OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), dce (2), dte1 (3), dte2 (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The variable is RW only if the communications protocol is sync. When the comm protocol is async, the variable is RO and its value is DCE." ::= { prtHsLsEntry 6} prtHsLsCtrlSignal OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), local (2), dtrAndRts (3), rts (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Control signals." ::= { prtHsLsEntry 7} prtHsLsCts OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), equalRts (2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "CTS Signal." ::= { prtHsLsEntry 8} prtHsLsRtsCtsDelay OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), min (2), ms10 (3), ms50 (4), ms100(5), ms200(6) } MAX-ACCESS read-write STATUS current DESCRIPTION "RTS-CTS delay in ms. notApplicable - when prtHsLsCts=on." ::= { prtHsLsEntry 9} prtHsLsDsrMode OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), permanentOn (2), sync (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "DSR Mode." ::= { prtHsLsEntry 10} prtHsLsSpeed OBJECT-TYPE SYNTAX INTEGER { notConnected(1), bps300 (2), bps600 (3), bps1200 (4), bps2400 (5), bps4800 (6), bps7200 (7), bps8000 (8), bps9600 (9), bps12000(10), bps14400(11), bps16000(12), bps16800(13), bps19200(14), bps21600(15), bps24000(16), bps26400(17), bps28800(18), bps31200(19), bps32000(20), bps33600(21), bps36000(22), bps38400(23), bps40800(24), bps43200(25), bps45600(26), bps48000(27), bps50400(28), bps52800(29), bps55200(30), bps56000(31), bps57600(32), bps60000(33), bps62400(34), bps64000(35), bps64800(36), bps67200(37), bps69600(38), bps72000(39), bps74400(40), bps76800(41), bps79200(42), bps81600(43), bps84000(44), bps86400(45), bps88800(46), bps91200(47), bps93600(48), bps96000(49), bps98400(50), bps100800(51), bps103200(52), bps105600(53), bps108000(54), bps110400(55), bps112800(56), bps115200(57), bps117600(58), bps120000(59), bps122400(60), bps124800(61), bps127200(62), bps128000(63), bps129600(64), bps134400(65), bps139200(66), bps144000(67), bps148800(68), bps153600(69), bps158400(70), bps163200(71), bps168000(72), bps172800(73), bps177600(74), bps182400(75), bps187200(76), bps192000(77), bps196800(78), bps201600(79), bps206400(80), bps211200(81), bps216000(82), bps220800(83), bps225600(84), bps230400(85), bps235200(86), bps240000(87), bps244800(88), bps249600(89), bps254400(90), bps256000(91), bps259200(92), bps264000(93), bps268800(94), bps273600(95), bps278400(96), bps283200(97), bps288000(98), bps292800(99), bps297600(100), bps302400(101), bps307200(102), bps316800(103), bps326400(104), bps336000(105), bps345600(106), bps355200(107), bps364800(108), bps374400(109), bps384000(110), bps393600(111), bps403200(112), bps412800(113), bps422400(114), bps432000(115), bps441600(116), bps451200(117), bps460800(118), bps470400(119), bps480000(120), bps489600(121), bps499200(122), bps508800(123), bps518400(124), bps528000(125), bps537600(126), bps547200(127), bps556800(128), bps566400(129), bps576000(130), bps585600(131), bps595200(132), bps604800(133), bps614400(134) } MAX-ACCESS read-write STATUS current DESCRIPTION "KLS.1 supports (Kbps): 0.3, 0.6, 1.2, 2.4, 4.8, 9.6, 19.2, 38.4. KLS.1/New, KDI/CH support (Kbps): Group 1: 0.3, 0.6, 1.2, 2.4, 4.8, 9.6, 19.2, 38.4 Group 2: 7.2, 14.4, 28.8, 57.6 Group 3: 8, 16, 24, 32, 48, 56, 64 KLS.2 supports (Kbps): 2.4, 4.8, 9.6, 19.2. KHS.1 supports (Kbps): 32, 48, 56, 64, 128, 192, 256, 384 KHS.2 supports (Kbps): ... KHSU.1/2 support (Kbps): 16, 32, 64. KHS.703 support (Kbps): 64." ::= { prtHsLsEntry 11} prtHsLsUType OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), regular(2), type1 (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "U Interface Type. Applicable for KHSU.1/2 cards. The value will be the same for B1 and B2 pair; B3 and B4." ::= { prtHsLsEntry 12} prtTreMbe OBJECT IDENTIFIER ::= {prtKmux 3} prtTreMbeTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtTreMbeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry. Parameters for the channels of the TRE and MBE cards: KTRE, KMBE, KMBE/NEW." ::= {prtTreMbe 2} prtTreMbeEntry OBJECT-TYPE SYNTAX PrtTreMbeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtTreMbeCnfgIdx, prtTreMbeIdx } ::= { prtTreMbeTable 1} PrtTreMbeEntry ::= SEQUENCE { prtTreMbeCnfgIdx Integer32, prtTreMbeIdx Integer32, prtTreMbeSlt INTEGER, prtTreMbeLan INTEGER, prtTreMbeLanRate INTEGER, prtTreMbeLinkSpeed INTEGER } prtTreMbeCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg." ::= {prtTreMbeEntry 1} prtTreMbeIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique port identifier within the card. Slot*100+11 ." ::= {prtTreMbeEntry 2} prtTreMbeSlt OBJECT-TYPE SYNTAX INTEGER { kmxIO1 (107), kmxIO2 (108), kmxIO3 (109), kmxIO4 (110), kmxIO5 (111), kmxIO6 (112), kmxIO7 (113), kmxIO8 (114), kmxIO9 (115), kmxIO10(116), kmxIO11(117), kmxIO12(118) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique number to identify the slot where the card is inserted in. In the 2104 Unit the entries kmxIO5(111)..kmxIO12(118) are not valid." ::= {prtTreMbeEntry 3} prtTreMbeLan OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), main (2), remote (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the TRE/MBE port is operated as main or remote bridge. Default=remote." ::= {prtTreMbeEntry 4} prtTreMbeLanRate OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), r4M (2), r16M (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the Rate of the TRE port in Mbit/sec. Default-r4M." ::= {prtTreMbeEntry 5} prtTreMbeLinkSpeed OBJECT-TYPE SYNTAX INTEGER { notConnected(1), bps9600 (2), bps19200 (3), bps28800 (4), bps38400 (5), bps48000 (6), bps57600 (7), bps67200 (8), bps76800 (9), bps86400 (10), bps96000 (11), bps105600(12), bps115200(13), bps124800(14), bps128000(15), bps160000(16), bps192000(17), bps224000(18), bps240000(19), bps272000(20), bps304000(21), bps336000(22), bps368000(23) } MAX-ACCESS read-write STATUS current DESCRIPTION "The Link Speed." ::= {prtTreMbeEntry 6} prtVoiceFax OBJECT IDENTIFIER ::= {prtKmux 4} prtVoiceFaxTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtVoiceFaxEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry. Parameters for the channels of the Voice and Fax channels. Cards: KVC.1/E&M, KVC.1/FXO, KVC.1/FXS, KVC.1M/E&M, KVC.1M/FXO, KVC.1M/FXS, KVC.1M/FXSW, KVC.2/E&M, KVC.2/FXO, KVC.2/FXS, KVC.2/1/E&M,KVC.2/1/FXO,KVC.2/1/FXS, KVC.3/E&M, KVC.3/FXO, KVC.3/FXS, KVC.3/S0 KVF.1/E&M, KVF.1/FXO, KVF.1/FXS, KVF.3/E&M, KVF.3/FXO, KVF.3/FXS, KVF.4/E&M, KVF.4/FXO, KVF.4/FXS, KVF.4/FXSW, KVF.4/S0, KVF.4/FXO3, KVF.4/FXS3, KVF.4/NS0 KVF.5 family, KVF.6 family, KVF.8 family." ::= { prtVoiceFax 1} prtVoiceFaxEntry OBJECT-TYPE SYNTAX PrtVoiceFaxEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtVoiceFaxCnfgIdx, prtVoiceFaxIdx } ::= { prtVoiceFaxTable 1} PrtVoiceFaxEntry ::= SEQUENCE { prtVoiceFaxCnfgIdx Integer32, prtVoiceFaxIdx Integer32, prtVoiceFaxSlt INTEGER, prtVoiceFaxTransGain Integer32, prtVoiceFaxReceiveGain Integer32, prtVoiceFaxWire INTEGER, prtVoiceFaxTimeOut INTEGER, prtVoiceFaxEchoCanceler INTEGER, prtVoiceFaxSpeed INTEGER, prtVoiceFaxMeterRate INTEGER, prtVoiceFaxCodingLaw INTEGER, prtVoiceFaxOperMode INTEGER, prtVoiceFaxSigInOutband OCTET STRING, prtVoiceFaxTsGroup INTEGER, prtVoiceFaxRxFaxGain Integer32, prtVoiceFaxSigHold INTEGER, prtVoiceFaxIfSignaling INTEGER, prtVoiceFaxEMTypes INTEGER, prtVoiceFaxRingFrequency INTEGER, prtVoiceFaxSignalingStatus OCTET STRING } prtVoiceFaxCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg." ::= {prtVoiceFaxEntry 1} prtVoiceFaxIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier of the port, within the card. Slot*100+Ch external ports: Ch=1..10 internal ports (sub-channels): Ch=11..20." ::= {prtVoiceFaxEntry 2} prtVoiceFaxSlt OBJECT-TYPE SYNTAX INTEGER { kmxIO1 (107), kmxIO2 (108), kmxIO3 (109), kmxIO4 (110), kmxIO5 (111), kmxIO6 (112), kmxIO7 (113), kmxIO8 (114), kmxIO9 (115), kmxIO10(116), kmxIO11(117), kmxIO12(118) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique number to identify the slot where the card is inserted in. In the 2104 Unit the entries kmxIO5(111)..kmxIO12(118) are not valid." ::= {prtVoiceFaxEntry 3} prtVoiceFaxTransGain OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Transmit gain in dBm. A value of 255 is for notApplicable. The value will be: real value+50dBm (in order to avoid negative values)." ::= {prtVoiceFaxEntry 4} prtVoiceFaxReceiveGain OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Receive gain in dBm. A value of 255 is for notApplicable. The value will be: real value+50dBm (in order to avoid negative values)." ::= {prtVoiceFaxEntry 5} prtVoiceFaxWire OBJECT-TYPE SYNTAX INTEGER {notApplicable(1), w2wire (2), w4wire (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable only for E&M cards." ::= {prtVoiceFaxEntry 6} prtVoiceFaxTimeOut OBJECT-TYPE SYNTAX INTEGER {notApplicable(1), manual(2), sec30 (3), sec60 (4), sec90 (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Fax timeout in seconds." ::= {prtVoiceFaxEntry 7} prtVoiceFaxEchoCanceler OBJECT-TYPE SYNTAX INTEGER {notApplicable(1), off (2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Echo canceler activation." ::= {prtVoiceFaxEntry 8} prtVoiceFaxSpeed OBJECT-TYPE SYNTAX INTEGER {notConnected(1), bps4800(2), bps6400(3), bps7200(4), bps8000(5), bps9600(6), bps12800(7), bps16000(8), bps24000(9), bps32000(10), bps64000(11), bps11200(12) } MAX-ACCESS read-write STATUS current DESCRIPTION "The channel speed. For KVF.6 and KVF.8 cards, each value will represent [4 x value], since each channel (Internal or External) is comprised of 4 sub-channels having the selected value." ::= {prtVoiceFaxEntry 9} prtVoiceFaxMeterRate OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), r16Khz (2), r12Khz (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This entry is valid to KVF.4/FXO3 and KVF.4/FXS3. Meter Rate means rate of Call Meter in Public Phones, in KHz units. Must be equal for both channels." ::= {prtVoiceFaxEntry 10} prtVoiceFaxCodingLaw OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), aLaw (2), uLaw (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Coding Law. This entry is valid for KVF.4/NS0 external channel and KVF.6 internal channels." ::= {prtVoiceFaxEntry 11} prtVoiceFaxOperMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), voiceANDfax (2), voice (3), voiceAndFaxAndData (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Operation Mode. This parameter is valid for KVF.6 and KVF.8 family." ::= {prtVoiceFaxEntry 12} prtVoiceFaxSigInOutband OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2)) MAX-ACCESS read-write STATUS current DESCRIPTION "This object is applicable for KVF.4/FXO3, KVF.4/FXS3, KVF.8 family cards. For KVF.4/FXO3, KVF.4/FXS3: Octet 1 for Receive parameters. Octet 2 for Transmit parameters. It represents 4 parameters, in each Octet : Bit 7 6 5 4 3 2 1 0 |_____| |_____| |_____| |_____| MSB Spare On/Off Hook Metering Polarity LSB Each parameter's bits represent: 00 = NC 01 = Inband(A/B) 10 = Outband(A) 11 = Outband(B) For KVF.8 family: It represents 4 parameters, by 2 Octets : General Bit Code- MSB nibble, On/Off Hook Bit Code- nibble, Metering Bit Code- nibble, Polarity Bit Code- LSB nibble. Each of General, On/Off Hook, Metering, Polarity Bit Code nibble represents: 0 hex = 0000 = 0 1 hex = 0001 = 1 2 hex = 0010 = A bit 3 hex = 0011 = B bit 4 hex = 0100 = C bit 5 hex = 0101 = D bit 6 hex = 0110 = A bit inverse 7 hex = 0111 = B bit inverse 8 hex = 1000 = C bit inverse 9 hex = 1001 = D bit inverse A-E hex - not used (invalid values) When the object is not applicable, 0 Octets will be sent." ::= {prtVoiceFaxEntry 13} prtVoiceFaxTsGroup OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), s1s2s3s4 (2), s5s6s7s8 (3), s9s10s11s12 (4), s13s14s15s16 (5), s17s18s19s20 (6), s21s22s23s24 (7), s25s26s27s28 (8), s29s30s31 (9) } MAX-ACCESS read-write STATUS current DESCRIPTION "Ts Assignment group. Each KVF.6 internal channel should have a different value. 's21s22s23s24' = TSs: 21, 22, 23, 24 For KVF.6/E1/16, KVF.6/E1/31 values: 2..9 are applicable. For KVF.6/T1/12, KVF.6/T1/24 values: 2..7 are applicable." ::= {prtVoiceFaxEntry 14} prtVoiceFaxRxFaxGain OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "FAX Receive gain in dBm. The value will be: (real value*10)+500dBm (in order to avoid negative and fractional values)." ::= {prtVoiceFaxEntry 15} prtVoiceFaxSigHold OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), sec0(2), sec10(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Signal Hold in [sec]. Applicable for all KVF.4 cards except S0/NS0. When a ML fails, instead of interrupting immediately a conversation and connecting it again when ML operation is resumed, user can select to Hold the signal a few seconds before interruption (ML operation may return during this time). sec0 = No Hold = 0 sec sec10= 10 sec hold." ::= {prtVoiceFaxEntry 16} prtVoiceFaxIfSignaling OBJECT-TYPE SYNTAX INTEGER {notApplicable (1), loopStart (2), groundStart (3), winkStart (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable only for KVF.8/FXO, KVF.8/FXS cards. Interface Analog Signaling." ::= {prtVoiceFaxEntry 17} prtVoiceFaxEMTypes OBJECT-TYPE SYNTAX INTEGER {notApplicable (1), em1 (2), em2 (3), em3 (4), ssdc5 (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable only for KVF.8/E&M card." ::= {prtVoiceFaxEntry 18} prtVoiceFaxRingFrequency OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), f16dot7Hz (2), f20Hz (3), f25Hz (4), f50Hz (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable only for KVF.8/E&M card. The Ringing Frequency units will be in Hz." ::= {prtVoiceFaxEntry 19} prtVoiceFaxSignalingStatus OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..2)) MAX-ACCESS read-write STATUS current DESCRIPTION "For KM-2100 this parameter should be Read Only. This object is applicable for KVF.6 and KVF.5 family cards. It shows the status (0 or 1) of each Signaling Bit (A, B, C, D), for each TS of a TS Group (according to it's position in the group). Each nibble represent a TS from the 'TS Group' selected for the channel (two Octets represents 4 TSs of each group): Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 |________| |________| |________| |________| MSB TS i+3 TS i+2 TS i+1 TS i LSB It represents 4 parameters for each TS: TS-i TS-i+1 .. 0 - A bit 4 - A bit 1 - B bit 5 - B bit 2 - C bit 6 - C bit 3 - D bit 7 - D bit When the object is not applicable, 0 Octets will be sent." ::= {prtVoiceFaxEntry 20} -- -- file :v:\doc\rdv\mib\Before~1\imx.txt -- --RAD-IMX-MIB -- RAD-IMX MIB (Inverse Multiplexer) --Title: RAD's IMX-64 PRODUCT MIB --Version: 1.0 --Date: 1.8.96 --By: Yair Arian --File: imx.mib -- --Update: 16.09.99 by Smadar (corrected conflicts with existing RAD MIB). --Last Update : 06.01.00 by Smadar (added comments for Traps) imx OBJECT IDENTIFIER ::= {radWan 7} systemImx OBJECT IDENTIFIER ::= {imx 1} generalImx OBJECT IDENTIFIER ::= {systemImx 1} sysGenClearAlarm OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Clear the alarm buffer. The agent resets the variable automatically to off." ::= { generalImx 1} sysGenAlarmBuffTable OBJECT-TYPE SYNTAX SEQUENCE OF SysGenAlarmBuffEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The alarm buffer of the imx." ::= { generalImx 2 } sysGenAlarmBuffEntry OBJECT-TYPE SYNTAX SysGenAlarmBuffEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table sysGenAlarmBuffTable." INDEX {sysGenAlarmBuffIndex} ::= { sysGenAlarmBuffTable 1} SysGenAlarmBuffEntry ::= SEQUENCE { sysGenAlarmBuffIndex Integer32, sysGenAlarmDescr DisplayString } sysGenAlarmBuffIndex OBJECT-TYPE SYNTAX Integer32 (1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the alarm buffer Table." ::= { sysGenAlarmBuffEntry 1} sysGenAlarmDescr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The description of the alarm. Up to 80 chars." ::= { sysGenAlarmBuffEntry 2} sysGenClearLog OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Clear the log buffer. The agent resets the variable automatically to off." ::= { generalImx 3} sysGenLogTable OBJECT-TYPE SYNTAX SEQUENCE OF SysGenLogEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The call log buffer of the imx." ::= { generalImx 4 } sysGenLogEntry OBJECT-TYPE SYNTAX SysGenLogEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table sysGenLogTable." INDEX {sysGenLogIndex} ::= { sysGenLogTable 1} SysGenLogEntry ::= SEQUENCE { sysGenLogIndex Integer32, sysGenLogDescr DisplayString } sysGenLogIndex OBJECT-TYPE SYNTAX Integer32 (1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the log Table." ::= { sysGenLogEntry 1} sysGenLogDescr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The description of the entry in the log buffer. Up to 80 chars." ::= { sysGenLogEntry 2} profilesImx OBJECT IDENTIFIER ::= {systemImx 2} callProfileImx OBJECT IDENTIFIER ::= {profilesImx 1} sysCallProfileTable OBJECT-TYPE SYNTAX SEQUENCE OF SysCallProfileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table containing call profile parameters. There are 40 call profiles." ::= { callProfileImx 1 } sysCallProfileEntry OBJECT-TYPE SYNTAX SysCallProfileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table sysCallProfileTable." INDEX {sysCallProfileIndex} ::= {sysCallProfileTable 1} SysCallProfileEntry ::= SEQUENCE { sysCallProfileIndex Integer32, sysCallProfileConnectCmd INTEGER, sysCallProfileDisconnectCmd INTEGER, sysCallProfileIncrBwCmd Integer32, sysCallProfileDecrBwCmd Integer32 } sysCallProfileIndex OBJECT-TYPE SYNTAX Integer32 (1..40) MAX-ACCESS read-only STATUS current DESCRIPTION "A running index for the table." ::= { sysCallProfileEntry 1} sysCallProfileConnectCmd OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "On(2) - Connect the call profile. The agent will automatically reset the variable to off(1) ." ::= { sysCallProfileEntry 2} sysCallProfileDisconnectCmd OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "On(2) - Disconnect the call profile. The agent will automatically reset the variable to off(1)." ::= { sysCallProfileEntry 3} sysCallProfileIncrBwCmd OBJECT-TYPE SYNTAX Integer32 (0..6) MAX-ACCESS read-write STATUS current DESCRIPTION "Increment bandwidth of a call. The number of channels to increment 1..6. The agent will automatically reset the variable to 0." ::= { sysCallProfileEntry 4} sysCallProfileDecrBwCmd OBJECT-TYPE SYNTAX Integer32 (0..6) MAX-ACCESS read-write STATUS current DESCRIPTION "Decrement bandwidth of a call. The number of channels to decrement 1..6. The agent will automatically reset the variable to 0." ::= { sysCallProfileEntry 5} portImx OBJECT IDENTIFIER ::= {imx 2} userPortImx OBJECT IDENTIFIER ::= {portImx 1} prtCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table containing configuration parameters for the user ports." ::= { userPortImx 1 } prtCnfgEntry OBJECT-TYPE SYNTAX PrtCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table prtCnfgTable." INDEX {prtIndex} ::= {prtCnfgTable 1} PrtCnfgEntry ::= SEQUENCE { prtIndex Integer32, prtCnfgDecrBwChNum Integer32, prtCnfgIncrBwChNum Integer32, prtCnfgDisconnect INTEGER, prtCnfgActivateLoop INTEGER, prtCnfgClearLoop INTEGER, prtCnfgLoopStatus Integer32 } prtIndex OBJECT-TYPE SYNTAX Integer32 (1..2) MAX-ACCESS read-only STATUS current DESCRIPTION "The user port index." ::= { prtCnfgEntry 1} prtCnfgDecrBwChNum OBJECT-TYPE SYNTAX Integer32 (0..6) MAX-ACCESS read-write STATUS current DESCRIPTION "Decrement the port bandwidth by the specified number of channels. The agent resets the variable to 0." ::= { prtCnfgEntry 2} prtCnfgIncrBwChNum OBJECT-TYPE SYNTAX Integer32 (0..6) MAX-ACCESS read-write STATUS current DESCRIPTION "Increment the port bandwidth by the specified number of channels. The agent resets the variable to 0." ::= { prtCnfgEntry 3} prtCnfgDisconnect OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Disconnect the port (on(1)). The agent resets the variable to off(2)." ::= { prtCnfgEntry 4} prtCnfgActivateLoop OBJECT-TYPE SYNTAX INTEGER { none(1), local(2), remote(3), bonding(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Activate the desired loop on the port. The agent will reset the variable to none(1)." ::= { prtCnfgEntry 5} prtCnfgClearLoop OBJECT-TYPE SYNTAX INTEGER { none(1), local(2), remote(3), bonding(4), all(5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Clear the desired loop from the port. The agent will reset the variable to none(1)" ::= { prtCnfgEntry 6} prtCnfgLoopStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The loop status at this port. The variable is a sum of 2**n where n is as follows: 0 - Local Loop is on. 1 - Remote Loop is on. 2 - BONDING Loop is on. If the variable is 0, there is no active loop." ::= { prtCnfgEntry 7} supervisoryPortImx OBJECT IDENTIFIER ::= {portImx 2} prtSpUsageImx OBJECT-TYPE SYNTAX INTEGER { nmsSlip(2), terminal(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The supervisory port terminal usage definition." ::= { supervisoryPortImx 1} channelImx OBJECT IDENTIFIER ::= {imx 4} channelCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF ChannelCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table containing configuration parameters for the channels." ::= { channelImx 1 } channelCnfgEntry OBJECT-TYPE SYNTAX ChannelCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table channelCnfgTable." INDEX {chIndex} ::= {channelCnfgTable 1} ChannelCnfgEntry ::= SEQUENCE { chIndex Integer32, chCnfgUnlock INTEGER, chCnfgPing INTEGER } chIndex OBJECT-TYPE SYNTAX Integer32 (1..6) MAX-ACCESS read-only STATUS current DESCRIPTION "The channel index." ::= { channelCnfgEntry 1} chCnfgUnlock OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Unlock the channel (on). The agent resets the variable to off." ::= { channelCnfgEntry 2} chCnfgPing OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Ping the channel (on). The agent resets the variable to off." ::= { channelCnfgEntry 3} channelStatTable OBJECT-TYPE SYNTAX SEQUENCE OF ChannelStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table containing status and statistics information for the channels." ::= { channelImx 2 } channelStatEntry OBJECT-TYPE SYNTAX ChannelStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table channelStatTable." INDEX {chIndex} ::= {channelStatTable 1} ChannelStatEntry ::= SEQUENCE { chStatOperStatus INTEGER } chStatOperStatus OBJECT-TYPE SYNTAX INTEGER { up(1), down(2), engaged(3), notDedicated(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The operational state of the channel based on a ping operation." ::= { channelStatEntry 1} -- Traps imxAlarmTrap NOTIFICATION-TYPE STATUS current DESCRIPTION "The trap is sent every time a new alarm is logged into the alarm buffer. The trap may not be sent more than once in a five second interval." ::= { radSysWanEvents 2 } imxCallLogTrap NOTIFICATION-TYPE STATUS current DESCRIPTION "The trap is sent every time a new call log entry is logged into the log buffer. The trap may not be sent more than once in a five second interval." ::= { radSysWanEvents 3 } imxPingTrap NOTIFICATION-TYPE OBJECTS {chStatOperStatus} STATUS current DESCRIPTION "The trap is sent every time a ping operation is performed on a channel." ::= { radSysWanEvents 4 } -- Traps 5-7 having the same enterprise, are used by ipmux.txt. -- -- file :v:\doc\rdv\mib\ver485\atm\nteprtconfg.txt -- -- ************************* -- file : NtePrtConfg.txt -- --Version: 1.0 --Date: 12.11.97 --By: Ilana Schvetz --File: v:\doc\rdv\mib\ver480\atm\NtePrtConfg.txt --Last Update: 30-Sep-01 by Ilana Schvetz -- Copyright 1997 RAD Data Communications, Ltd. -- All Rights Reserved. atmNte OBJECT IDENTIFIER ::= { radAtm 3 } atmNtePrt OBJECT IDENTIFIER ::= { atmNte 2 } atmNtePrtConfig OBJECT IDENTIFIER ::= { atmNtePrt 1 } atmNteEvents OBJECT-IDENTITY STATUS current DESCRIPTION "The events for RAD ATM products." ::= { atmNte 0 } atmNteConfIfTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmNteConfIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Physical interface configuration table." ::= { atmNtePrtConfig 1 } atmNteConfIfEntry OBJECT-TYPE SYNTAX AtmNteConfIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Physical interface configuration table. The ifIndex is of the lowest physical layer." INDEX { ifIndex} ::= { atmNteConfIfTable 1 } AtmNteConfIfEntry ::= SEQUENCE { atmConfIfTransmitClk INTEGER, atmConfIfLoopback INTEGER, atmConfIfFrameType INTEGER, atmConfIfCardType INTEGER, atmConfAtmIfVpiVciLimit INTEGER, atmConfIfHwFeatures INTEGER, atmConfIfOutputRate Integer32, atmConfIfInputRate Integer32, atmConfAlarmForwarding INTEGER } atmConfIfTransmitClk OBJECT-TYPE SYNTAX INTEGER { internal(2), external(3), loopback(4), adaptive(5) } MAX-ACCESS read-write STATUS current DESCRIPTION "The transmit clock of the port." ::= { atmNteConfIfEntry 1 } atmConfIfLoopback OBJECT-TYPE SYNTAX INTEGER { internal(2), external(3), disable(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Interface Loopback." ::= { atmNteConfIfEntry 2 } atmConfIfFrameType OBJECT-TYPE SYNTAX INTEGER { other (1), sonet (2), sdh (3), direct (4), plcpInternal (5), plcpExternal (6), e3 (7), ethCrcTrans (8), ethCrcNotTrans (9), directNoScrmbling (10), plcpInternalNoScrmbling (11), plcpExternalNoScrmbling (12) } MAX-ACCESS read-write STATUS current DESCRIPTION "The frame type. Valid values for a 155M interface: sonet(2), sdh(3). Valid values for a T3 interface: direct(4), plcpInternal(5), plcpExternal(6), directNoScrmbling(10), plcpInternalNoScrmbling(11), plcpExternalNoScrmbling(12). Valid values for Ethernet interface: ethCrcTrans (8), ethCrcNotTrans(9). (DS1 interfaces frame type is specified in the DSX1 mib)." ::= { atmNteConfIfEntry 3 } atmConfIfCardType OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), sc13m-155(2), st13s-155(3), st13l-155(4), utp-155(5), cx-bnc-155(6), e3(7), t3(8), e1(9), e1-ltu(10), fc13l-155(11), fc13lh-155(12), fc15lh-155(13), fc13l-e3(14), fc13lh-e3(15), fc15lh-e3(16), fc13l-t3(17), fc13lh-t3(18), fc15lh-t3(19) } MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The card type." ::= { atmNteConfIfEntry 4 } atmConfAtmIfVpiVciLimit OBJECT-TYPE SYNTAX INTEGER { bits15(2), bits17(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The limit on the sum of the VPI+VCI bits for this interface." ::= { atmNteConfIfEntry 5 } atmConfIfHwFeatures OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "HW features command." ::= { atmNteConfIfEntry 6 } atmConfIfOutputRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter indicates the output rate in cells/sec, which is supported per port. Successfully setting this parameter is dependent on all other ports values calculations, which are described in the NMS SRS." ::= { atmNteConfIfEntry 7 } atmConfIfInputRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter indicates the input rate in cells/sec, which is supported per port. Successfully setting this parameter is dependent on all other ports values calculations, which are described in the NMS SRS." ::= { atmNteConfIfEntry 8 } atmConfAlarmForwarding OBJECT-TYPE SYNTAX INTEGER { disable(2), enable(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables Path AIS Alarm forwarding upon a failure detection. The following might be considered as a failure: LOS, LOF, LOC, SLM, LOP, Path AIS and Line AIS. disable(2) - will not forward an alarm upon a failure on this port. enable(3) - will forward an alarm upon a failure on this port." ::= { atmNteConfIfEntry 9 } atmNteAlarmIfTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmNteAlarmIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The interface Alarm table." ::= { atmNtePrtConfig 2 } atmNteAlarmIfEntry OBJECT-TYPE SYNTAX AtmNteAlarmIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the interface Alarm table." INDEX { ifIndex} ::= { atmNteAlarmIfTable 1 } AtmNteAlarmIfEntry ::= SEQUENCE { atmInterfaceActiveAlarms Integer32, atmThresholdSectionBIP Integer32, atmThresholdLineBIP Integer32, atmThresholdLineFEBE Integer32, atmThresholdPathBIP Integer32, atmThresholdPathFEBE Integer32, atmThresholdErroredCells Integer32, atmThresholdLostCells Integer32, atmThresholdMisinsertedCells Integer32, atmInterfaceAlarmStatus INTEGER, atmInterfaceMaskAlarms Integer32 } atmInterfaceActiveAlarms OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A Bit String of the active alarms on this interface. An up bit (1) means there is an active alarm of this type. A down bit (0) means there is no such alarm. The meaning of the bits is as follows: 1 - LOS 2 - LOF 3 - Line AIS (SONET)/ PLCP LOF (DS3) 4 - LOP 5 - Path AIS 6 - SLM 7 - LCD 8 - Line RDI (SONET)/ PLCP Yellow (DS3) 9 - Path RDI (SONET)/ RDI (DS3) 10 - Section BIP (SONET)/ P1/P2 (DS3) > Threshold 11 - Line BIP (SONET)/ PLCP BIP (DS3) > Threshold 12 - Line FEBE (SONET)/ PLCP FEBE (DS3) > Threshold 13 - Path BIP > Threshold 14 - Path FEBE > Threshold 15 - HW Failure " ::= { atmNteAlarmIfEntry 1 } atmThresholdSectionBIP OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "When Section BIPs are greater than this threshold, an active alarm is raised. N/A for ds3/e3 interface." ::= { atmNteAlarmIfEntry 2 } atmThresholdLineBIP OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "When Line BIPs are greater than this threshold, an active alarm is raised. N/A for ds3/e3 interface." ::= { atmNteAlarmIfEntry 3 } atmThresholdLineFEBE OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "When Line FEBEs are greater than this threshold, an active alarm is raised. N/A for ds3/e3 interface." ::= { atmNteAlarmIfEntry 4 } atmThresholdPathBIP OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "When Path BIPs are greater than this threshold, an active alarm is raised." ::= { atmNteAlarmIfEntry 5 } atmThresholdPathFEBE OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "When Path FEBEs are greater than this threshold, an active alarm is raised." ::= { atmNteAlarmIfEntry 6 } atmThresholdErroredCells OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "When Errored Cells are greater than this threshold, an active alarm is raised." ::= { atmNteAlarmIfEntry 7 } atmThresholdLostCells OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "When Lost Cells are greater than this threshold, an active alarm is raised." ::= { atmNteAlarmIfEntry 8 } atmThresholdMisinsertedCells OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "When Misinserted Cells are greater than this threshold, an active alarm is raised." ::= { atmNteAlarmIfEntry 9 } atmInterfaceAlarmStatus OBJECT-TYPE SYNTAX INTEGER { off(2), on(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The variable is on(3) when there is any active alarm on this interface." ::= { atmNteAlarmIfEntry 10 } atmInterfaceMaskAlarms OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "A Bit String of alarms mask on this interface. An up bit (1) means that the respective alarm is masked. A down bit (0) means no mask. The mask is supported for the following alarms: 1 - LOS " ::= { atmNteAlarmIfEntry 11 } atmNteConfVpTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmNteConfVpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ATM VP configuration table. The table is an extension to the atmVplTable of RFC-1695." ::= { atmNtePrtConfig 3 } atmNteConfVpEntry OBJECT-TYPE SYNTAX AtmNteConfVpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ATM VP configuration table. ifIndex of the ATM layer." INDEX { ifIndex, atmVplVpi } ::= { atmNteConfVpTable 1 } AtmNteConfVpEntry ::= SEQUENCE { atmConfVpPolicing INTEGER, atmConfVpCCAdminStatus INTEGER, atmConfVpLoopbackAdminStatus INTEGER, atmConfVpLoopbackSinkAddress OCTET STRING, atmConfVpCongestionControl OCTET STRING, atmConfVpCCDirection INTEGER, atmConfVpCreationTime DateAndTime, atmConfVpOamSupport INTEGER, atmConfVpCCOperStatus INTEGER, atmConfVpLoopbackTraffic INTEGER, atmConfVpLoopbackFailureInd INTEGER, atmConfVpLoopbackFailureThreshold Integer32, atmConfVpOamDirection INTEGER } atmConfVpPolicing OBJECT-TYPE SYNTAX INTEGER { none(1), police(2), monitor(3), shaping(4), policingAndShaping(5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Policing method desired for this VPL." ::= { atmNteConfVpEntry 1 } atmConfVpCCAdminStatus OBJECT-TYPE SYNTAX INTEGER { up (2), down (3), source(4), -- agent send Oam CC cells sink (5), -- agent check received Oam CC cells listenToActivationCells (6), originateActivationCells(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "up(2) - Activate Continuity Check (CC). down(3) - Deactivate CC. source(4) - Activate OAM CC(Continuity Check) of local agent ( start sending Oam cells to the remote side ). sink(5) - Activate CC of remote agent ( start receiving Oam cells from remote side ). listenToActivationCells (6) - Passive listener till gets an activation request originateActivationCells(7) - Sands Activation cell according to atmConfVcCCDirection." ::= {atmNteConfVpEntry 2} atmConfVpLoopbackAdminStatus OBJECT-TYPE SYNTAX INTEGER { up(2), down(3), llid(4), segment(5), endToEnd(6), segmentLlid(7), endToEndLlid(8) } MAX-ACCESS read-write STATUS current DESCRIPTION "up(2) - Start loopback OAM cells. down(3) - Stop sending loopback OAM cells. For ace2002: up(2) - Transmitting LB cells with llid all ones (i.e. FFFF..FF) down(3) - Not transmitting LB cells. llid(4) - Transmitting LB cells with llid indicated in the address field. segment(5) - Transmitting Segment LB cells with llid all ones. endToEnd(6) - Transmitting End to End LB cells with llid all ones. segmentLlid(7) - Transmitting Segment LB cells with llid indicated in the address field. endToEndLlid(8) - Transmitting LB cells with llid indicated in the address field. This parameter value might be in conflict with atmConfVpOamSupport value, since this parameter is for LB, while atmConfVpOamSupport is for any other OAM cells." ::= {atmNteConfVpEntry 3} atmConfVpLoopbackSinkAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "Destination address. For ace101: 2 bytes are used. For ace2002: 16 bytes are used." ::= {atmNteConfVpEntry 4} atmConfVpCongestionControl OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Each bit indicates a selection of one option as the following description. All combinations are possible and legal. The codes are: 1 - EPD 2 - CLP 4 - EFCI" ::= {atmNteConfVpEntry 5} atmConfVpCCDirection OBJECT-TYPE SYNTAX INTEGER { both (2), source(4), sink (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "both(2) - Agent send OAM CC cells and check received OAM CC cells source(4)- Agent send OAM CC cells. sink(5) - Agent checks received OAM CC cells." ::= {atmNteConfVpEntry 6} atmConfVpCreationTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "A date-time in which the VP was created." ::= { atmNteConfVpEntry 7 } atmConfVpOamSupport OBJECT-TYPE SYNTAX INTEGER { intermediate(1), segmentTermination(2), endToEndTermination(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "OAM support mode, which determines the device location in a segment wise." ::= { atmNteConfVpEntry 8 } atmConfVpCCOperStatus OBJECT-TYPE SYNTAX INTEGER { initial (1), source(4), sink (5), both (8), timeout (9), denied (10), conflict (11), manual (12) } MAX-ACCESS read-only STATUS current DESCRIPTION " initial(1) - The CC activation process is not started. source(4) - Agent sends OAM CC cells. sink(5) - Agent checks received OAM CC cells. both (8) - OAM CC of local and remote agents activation. timeout (9) - Timeout occured on receiving answer from the remote agent. denied (10) - CC activation process rejected by remote agent. conflict (11) - local and remote sides requested activation simultaneously. manual (12) - OAM CC of local agent activated manually. " ::= {atmNteConfVpEntry 9} atmConfVpLoopbackTraffic OBJECT-TYPE SYNTAX INTEGER { off(2), on(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter has both command and status meanings: off(2) - Set to 'Off' will Stop traffic loop. Getting this value means that the loop is not running. on (3) - Set to 'On' will start traffic loop. Getting this value means that the loop is currently running." ::= {atmNteConfVpEntry 10} atmConfVpLoopbackFailureInd OBJECT-TYPE SYNTAX INTEGER { disabled(2), segmentAis(3), segmentRdi(4), segmentAisAndRdi(5), endToEndAis(6), endToEndRdi(7), endToEndAisAndRdi(8) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object allows user to define the Indication that will be created upon a LB cell failure. disabled(2) - no indication will be created. segmentAis(3) - will cause Tx of a segment AIS. segmentRdi(4) - will cause Tx of a segment RDI. segmentAisAndRdi(5) - will cause Tx of a segment AIS & RDI. endToEndAis(6) - will cause Tx of an End to End AIS. endToEndRdi(7) - will cause Tx of an End to End RDI. endToEndAisAndRdi(8) - will cause Tx of an End to End AIS & RDI. Default: disabled(2)." ::= {atmNteConfVpEntry 11} atmConfVpLoopbackFailureThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The number of the LB failures before starting transmission of the Indication defined by atmConfVcLoopbackFailureInd. Range: 1..16. Default: 1." ::= {atmNteConfVpEntry 12} atmConfVpOamDirection OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), downStream (2), upStream (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The direction of OAM cell insertion. downStream(2) - The OAM cell will be inserted in downStream. upStream(3) - The OAM cell will be inserted in upStream." ::= {atmNteConfVpEntry 13} --Alarm Table atmNteAlarmVpTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmNteAlarmVpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ATM VP Alarm table." ::= { atmNtePrtConfig 5 } atmNteAlarmVpEntry OBJECT-TYPE SYNTAX AtmNteAlarmVpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ATM VP Alarm table. ifIndex of the ATM layer." INDEX { ifIndex, atmNteVpAlarmVpi} ::= { atmNteAlarmVpTable 1 } AtmNteAlarmVpEntry ::= SEQUENCE { atmNteVpAlarmVpi Integer32, atmNteVpActiveAlarms Integer32 } atmNteVpAlarmVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VPI on which there is an active alarm." ::= { atmNteAlarmVpEntry 1 } atmNteVpActiveAlarms OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A Bit String of the active alarms on this VP. An up bit (1) means there is an active alarm of this type. A down bit (0) means there is no such alarm. The meaning of the bits is as follows: 1 - VP AIS 2 - VP Loss Of Continuity 3 - VP RDI Reception 4 - VP Errored Cells > Threshold 5 - VP Lost Cells > Threshold 6 - VP Misinserted Cells > Threshold " ::= { atmNteAlarmVpEntry 2 } atmNteAlarmVcTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmNteAlarmVcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ATM VC Alarm table." ::= { atmNtePrtConfig 6 } atmNteAlarmVcEntry OBJECT-TYPE SYNTAX AtmNteAlarmVcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ATM VC Alarm table. ifIndex of the ATM layer." INDEX { ifIndex, atmNteVcAlarmVpi, atmNteVcAlarmVci} ::= { atmNteAlarmVcTable 1 } AtmNteAlarmVcEntry ::= SEQUENCE { atmNteVcAlarmVpi Integer32, atmNteVcAlarmVci Integer32, atmNteVcActiveAlarms Integer32 } atmNteVcAlarmVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VPI of the VC on which there is an active alarm." ::= { atmNteAlarmVcEntry 1 } atmNteVcAlarmVci OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VCI of the VC on which there is an active alarm." ::= { atmNteAlarmVcEntry 2 } atmNteVcActiveAlarms OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A Bit String of the active alarms on this VC. An up bit (1) means there is an active alarm of this type. A down bit (0) means there is no such alarm. The meaning of the bits is as follows: 1 - VC AIS 2 - VC Loss Of Continuity 3 - VC RDI 4 - VC Errored Cells > Threshold 5 - VC Lost Cells > Threshold 6 - VC Misinserted Cells > Threshold 7 - Tx VC AIS 8 - Tx VC RDI " ::= { atmNteAlarmVcEntry 3 } -- -- file :v:\doc\rdv\mib\ver485\atm\ace101.txt -- END -- -- file :v:\doc\rdv\mib\ver485\ace101.txt RAD-ARC-MIB DEFINITIONS ::= BEGIN --Title: RAD-ARC MIB -- -- IMPORTS -- Gauge32, IpAddress FROM RFC1155-SMI -- ifIndex FROM IF-MIB -- OBJECT-TYPE FROM RFC-1212 -- TRAP-TYPE FROM RFC-1215 -- radAtm, agnLed, agnIndication FROM RAD-GEN-MIB -- RowStatus FROM SNMPv2-TC -- atmVplVpi, atmVclVpi, atmVclVci FROM ATM-MIB; -- RAD-ARC MIB --Title: RAD's ARC ATM PRODUCT MIB --Version: 1.0 --Date: 24.9.96 --By: Yair Arian --File: arc.mib -- --Last update: 30-Sep-02 by Ilana Schvetz atmGen OBJECT IDENTIFIER ::= {radAtm 2} atmPerfHistory OBJECT IDENTIFIER ::= {atmGen 1} atmIfPerformance OBJECT IDENTIFIER ::= {atmPerfHistory 1} -- aal5VccXTable ::= { atmIfPerformance 4 } in aal5.txt atmIfDataTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmIfDataEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ATM interface Data table." ::= { atmIfPerformance 1 } atmIfDataEntry OBJECT-TYPE SYNTAX AtmIfDataEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ATM interface Data table." INDEX { ifIndex } ::= { atmIfDataTable 1 } AtmIfDataEntry ::= SEQUENCE { atmIfTimeElapsed Integer32, atmIfValidIntervals Integer32 } atmIfTimeElapsed OBJECT-TYPE SYNTAX Integer32 (0..899) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of seconds that have elapsed since the beginning of the near end current error- measurement period." ::= { atmIfDataEntry 1 } atmIfValidIntervals OBJECT-TYPE SYNTAX Integer32 (0..96) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of previous near end intervals for which valid data was collected. The value will be 96 unless the interface was brought online within the last 24 hours, in which case the value will be the number of complete 15 minute near end intervals since the interface has been online." ::= { atmIfDataEntry 2 } -- the ATM interface Current -- The ATM interface current table contains various statistics being -- collected for the current 15 minute interval. atmIfCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmIfCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ATM interface Current table." ::= { atmIfPerformance 2 } atmIfCurrentEntry OBJECT-TYPE SYNTAX AtmIfCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ATM interface Current table." INDEX { ifIndex } ::= { atmIfCurrentTable 1 } AtmIfCurrentEntry ::= SEQUENCE { atmIfCurrentTxCells Gauge32, atmIfCurrentRxCells Gauge32, atmIfCurrentCorrectedHecs Gauge32, atmIfCurrentUncorrectedHecs Gauge32 } atmIfCurrentTxCells OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted cells, encountered by an ATM interface in the current 15 minute interval." ::= { atmIfCurrentEntry 1 } atmIfCurrentRxCells OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received cells, encountered by an ATM interface in the current 15 minute interval." ::= { atmIfCurrentEntry 2 } atmIfCurrentCorrectedHecs OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of cells with corrected HEC errors, encountered by an ATM interface in the current 15 minute interval." ::= { atmIfCurrentEntry 3 } atmIfCurrentUncorrectedHecs OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of cells with uncorrected HEC errors, encountered by an ATM interface in the current 15 minute interval." ::= { atmIfCurrentEntry 4 } -- the ATM interface Interval -- The ATM interface Interval Table contains various statistics -- collected by each ATM Interface over the previous 24 -- hours of operation. The past 24 hours are broken into 96 -- completed 15 minute intervals. atmIfIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmIfIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ATM interface Interval table." ::= { atmIfPerformance 3 } atmIfIntervalEntry OBJECT-TYPE SYNTAX AtmIfIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ATM interface Interval table." INDEX { ifIndex, atmIfIntervalNumber } ::= { atmIfIntervalTable 1 } AtmIfIntervalEntry ::= SEQUENCE { atmIfIntervalNumber Integer32, atmIfIntervalTxCells Gauge32, atmIfIntervalRxCells Gauge32, atmIfIntervalCorrectedHecs Gauge32, atmIfIntervalUncorrectedHecs Gauge32 } atmIfIntervalNumber OBJECT-TYPE SYNTAX Integer32 (1..96) MAX-ACCESS read-only STATUS current DESCRIPTION "A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid)." ::= { atmIfIntervalEntry 1 } atmIfIntervalTxCells OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted cells , encountered by an ATM interface in one of the previous 96, individual 15 minute, intervals." ::= { atmIfIntervalEntry 2 } atmIfIntervalRxCells OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received cells, encountered by an ATM interface in one of the previous 96, individual 15 minute, intervals." ::= { atmIfIntervalEntry 3 } atmIfIntervalCorrectedHecs OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of cells with corrected HEC errors, encountered by an ATM interface in one of the previous 96, individual 15 minute, intervals." ::= { atmIfIntervalEntry 4 } atmIfIntervalUncorrectedHecs OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of cells with uncorrected HEC errors, encountered by an ATM interface in one of the previous 96, individual 15 minute, intervals." ::= { atmIfIntervalEntry 5 } atmPvcPerformance OBJECT IDENTIFIER ::= {atmPerfHistory 2} atmVpPerformance OBJECT IDENTIFIER ::= {atmPvcPerformance 1} -- the ATM VP Current -- The ATM VP current table contains various statistics being -- collected for the current 15 minute interval. atmVpCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmVpCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ATM VP Current table." ::= { atmVpPerformance 1 } atmVpCurrentEntry OBJECT-TYPE SYNTAX AtmVpCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ATM VP Current table." INDEX { ifIndex, atmVpCurrentVpi } ::= { atmVpCurrentTable 1 } AtmVpCurrentEntry ::= SEQUENCE { atmVpCurrentVpi Integer32, atmVpCurrentRxCellsClp01 Gauge32, atmVpCurrentRxCellsClp0 Gauge32, atmVpCurrentGcra0Violations Gauge32, atmVpCurrentGcra1Violations Gauge32, atmVpCurrentRxAIS Gauge32, atmVpCurrentTxAIS Gauge32, atmVpCurrentRxRDI Gauge32, atmVpCurrentTxRDI Gauge32, atmVpCurrentContinuityLoss Gauge32, atmVpCurrentUAS Gauge32, atmVpCurrentSES Gauge32, atmVpCurrentCDC Gauge32, atmVpCurrentTotalDiscards Gauge32, atmVpCurrentClp0Discards Gauge32, atmVpCurrentTotalCellOuts Gauge32, atmVpCurrentClp0CellOuts Gauge32, atmVpCurrentTaggedOuts Gauge32, atmVpCurrentPCR Gauge32, atmVpCurrentSCR Gauge32, atmVpCurrentMCR Gauge32 } atmVpCurrentVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VPI of the VPL." ::= { atmVpCurrentEntry 1 } atmVpCurrentRxCellsClp01 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted cells, encountered by the VPL of this ATM interface in the current 15 minute interval." ::= { atmVpCurrentEntry 2 } atmVpCurrentRxCellsClp0 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received cells, encountered by the VPL of this ATM interface in the current 15 minute interval." ::= { atmVpCurrentEntry 3 } atmVpCurrentGcra0Violations OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of cells violating GCRA0, encountered by the VPL of this ATM interface in the current 15 minute interval." ::= { atmVpCurrentEntry 4 } atmVpCurrentGcra1Violations OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of cells violating GCRA1, encountered by the VPL of this ATM interface in the current 15 minute interval." ::= { atmVpCurrentEntry 5 } atmVpCurrentRxAIS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received AIS cells, encountered by the VPL of this ATM interface in the current 15 minute interval." ::= { atmVpCurrentEntry 6 } atmVpCurrentTxAIS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted AIS cells, encountered by the VPL of this ATM interface in the current 15 minute interval. Not Supported in the first phase." ::= { atmVpCurrentEntry 7 } atmVpCurrentRxRDI OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received RDI cells, encountered by the VPL of this ATM interface in the current 15 minute interval." ::= { atmVpCurrentEntry 8 } atmVpCurrentTxRDI OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted RDI cells, encountered by the VPL of this ATM interface in the current 15 minute interval." ::= { atmVpCurrentEntry 9 } atmVpCurrentContinuityLoss OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of loss of continuity cells, encountered by the VPL of this ATM interface in the current 15 minute interval." ::= { atmVpCurrentEntry 10 } atmVpCurrentUAS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Unavailable Seconds, encountered by the VPL of this ATM interface in the current 15 minute interval." ::= { atmVpCurrentEntry 11 } atmVpCurrentSES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Severerly Errored Seconds, encountered by the VPL of this ATM interface in the current 15 minute interval." ::= { atmVpCurrentEntry 12 } atmVpCurrentCDC OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Amount of cells dropped in the current 15 minute interval of the VP connection." ::= { atmVpCurrentEntry 13 } atmVpCurrentTotalDiscards OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of valid ATM cells discarded by the traffic policing entity. This includes cells originally received with CLP=0 and CLP=1." ::= { atmVpCurrentEntry 14 } atmVpCurrentClp0Discards OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of valid ATM cells received with CLP=0 and discarded by the traffic policing entity." ::= { atmVpCurrentEntry 15 } atmVpCurrentTotalCellOuts OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of valid ATM cells transmitted by this VPL. This includes both CLP=0 and CLP=1 cells." ::= { atmVpCurrentEntry 16 } atmVpCurrentClp0CellOuts OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of valid ATM cells transmitted with CLP=0 by this VPL." ::= { atmVpCurrentEntry 17 } atmVpCurrentTaggedOuts OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of valid ATM cells tagged by the traffic policing entity from CLP=0 to CLP=1 and transmitted by this VPL." ::= { atmVpCurrentEntry 18 } atmVpCurrentPCR OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum traffic rate encountered in the last interval of the VP connection (monitored once a second)." ::= { atmVpCurrentEntry 19 } atmVpCurrentSCR OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The average traffic rate during the last interval of the VP connection." ::= { atmVpCurrentEntry 20 } atmVpCurrentMCR OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "MCR - The minimum traffic rate encountered in the last interval of the VP connection (monitored once a second)." ::= { atmVpCurrentEntry 21 } -- The ATM VP current table for Performance Management -- which contains various statistics being -- collected for the current 15 minute interval. atmVpPMCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmVpPMCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ATM VP Current table for Performance Management." ::= { atmVpPerformance 2 } atmVpPMCurrentEntry OBJECT-TYPE SYNTAX AtmVpPMCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ATM VP Current table for Performance Management." INDEX { ifIndex, atmVpPMCurrentVpi, atmVpPMCurrentDir } ::= { atmVpPMCurrentTable 1 } AtmVpPMCurrentEntry ::= SEQUENCE { atmVpPMCurrentDir INTEGER, atmVpPMCurrentVpi Integer32, atmVpPMCurrentTxClp01 Gauge32, atmVpPMCurrentTxClp0 Gauge32, atmVpPMCurrentRxClp01 Gauge32, atmVpPMCurrentRxClp0 Gauge32, atmVpPMCurrentErroredCells Gauge32, atmVpPMCurrentLostCells Gauge32, atmVpPMCurrentMisinsertedCells Gauge32, atmVpPMCurrentECB Gauge32, atmVpPMCurrentSECB Gauge32, atmVpPMCurrentES Gauge32, atmVpPMCurrentSES Gauge32, atmVpPMCurrentUAS Gauge32, atmVpPMCurrentIntervalQuality INTEGER, atmVpPMCurrentLastDayQuality INTEGER } atmVpPMCurrentVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VPI of the VPL." ::= { atmVpPMCurrentEntry 1 } atmVpPMCurrentDir OBJECT-TYPE SYNTAX INTEGER {forward(2), backward(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The direction of performance management." ::= { atmVpPMCurrentEntry 2 } atmVpPMCurrentTxClp01 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted CLP 0+1 cells, encountered by the VPL of this ATM interface in the current 15 minute interval." ::= { atmVpPMCurrentEntry 3 } atmVpPMCurrentTxClp0 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted CLP 0 cells, encountered by the VPL of this ATM interface in the current 15 minute interval." ::= { atmVpPMCurrentEntry 4 } atmVpPMCurrentRxClp01 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received CLP 0+1 cells, encountered by the VPL of this ATM interface in the current 15 minute interval." ::= { atmVpPMCurrentEntry 5 } atmVpPMCurrentRxClp0 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received CLP 0 cells, encountered by the VPL of this ATM interface in the current 15 minute interval." ::= { atmVpPMCurrentEntry 6 } atmVpPMCurrentErroredCells OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of errored cells, encountered by the VPL of this ATM interface in the current 15 minute interval." ::= { atmVpPMCurrentEntry 7 } atmVpPMCurrentLostCells OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of lost cells, encountered by the VPL of this ATM interface in the current 15 minute interval." ::= { atmVpPMCurrentEntry 8 } atmVpPMCurrentMisinsertedCells OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of misinserted cells, encountered by the VPL of this ATM interface in the current 15 minute interval." ::= { atmVpPMCurrentEntry 9 } atmVpPMCurrentECB OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of ECB, encountered by the VPL of this ATM interface in the current 15 minute interval." ::= { atmVpPMCurrentEntry 10 } atmVpPMCurrentSECB OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of SECB, encountered by the VPL of this ATM interface in the current 15 minute interval." ::= { atmVpPMCurrentEntry 11 } atmVpPMCurrentES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Errored Seconds, encountered by the VPL of this ATM interface in the current 15 minute interval." ::= { atmVpPMCurrentEntry 12 } atmVpPMCurrentSES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Severely Errored Seconds, encountered by the VPL of this ATM interface in the current 15 minute interval." ::= { atmVpPMCurrentEntry 13 } atmVpPMCurrentUAS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Unavailable Seconds, encountered by the VPL of this ATM interface in the current 15 minute interval." ::= { atmVpPMCurrentEntry 14 } atmVpPMCurrentIntervalQuality OBJECT-TYPE SYNTAX INTEGER { normal(2), unacceptable(3) } MAX-ACCESS read-only STATUS current DESCRIPTION " If the number of errors per interval is superior to the atmNteUPLTCR value, the quality of service of the interval is declared as unacceptable." DEFVAL { normal } ::= { atmVpPMCurrentEntry 15 } atmVpPMCurrentLastDayQuality OBJECT-TYPE SYNTAX INTEGER { normal(2), degraded(4) } MAX-ACCESS read-only STATUS current DESCRIPTION " If the number of errors per 24 hours is superior to the atmNteDPLTCR value, the quality of service of the day is declared as degraded." DEFVAL { normal } ::= { atmVpPMCurrentEntry 16 } -- the ATM VP Interval -- The ATM VP Interval Table contains various statistics -- collected by each ATM Interface/VP over the previous 24 -- hours of operation. The past 24 hours are broken into 96 -- completed 15 minute intervals. atmVpIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmVpIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ATM Vp Interval table." ::= { atmVpPerformance 3 } atmVpIntervalEntry OBJECT-TYPE SYNTAX AtmVpIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ATM Vp Interval table." INDEX { ifIndex, atmVpIntervalVpi, atmVpIntervalNumber } ::= { atmVpIntervalTable 1 } AtmVpIntervalEntry ::= SEQUENCE { atmVpIntervalVpi Integer32, atmVpIntervalNumber Integer32, atmVpIntervalRxCellsClp01 Gauge32, atmVpIntervalRxCellsClp0 Gauge32, atmVpIntervalGcra0Violations Gauge32, atmVpIntervalGcra1Violations Gauge32, atmVpIntervalRxAIS Gauge32, atmVpIntervalTxAIS Gauge32, atmVpIntervalRxRDI Gauge32, atmVpIntervalTxRDI Gauge32, atmVpIntervalContinuityLoss Gauge32, atmVpIntervalUAS Gauge32, atmVpIntervalSES Gauge32, atmVpIntervalCDC Gauge32, atmVpIntervalTotalDiscards Gauge32, atmVpIntervalClp0Discards Gauge32, atmVpIntervalTotalCellOuts Gauge32, atmVpIntervalClp0CellOuts Gauge32, atmVpIntervalTaggedOuts Gauge32, atmVpIntervalPCR Gauge32, atmVpIntervalSCR Gauge32, atmVpIntervalMCR Gauge32 } atmVpIntervalVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VPI of the VPL." ::= { atmVpIntervalEntry 1 } atmVpIntervalNumber OBJECT-TYPE SYNTAX Integer32 (1..96) MAX-ACCESS read-only STATUS current DESCRIPTION "A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid)." ::= { atmVpIntervalEntry 2 } atmVpIntervalRxCellsClp01 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted cells , encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpIntervalEntry 3 } atmVpIntervalRxCellsClp0 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpIntervalEntry 4 } atmVpIntervalGcra0Violations OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of cells violating GCRA0, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpIntervalEntry 5 } atmVpIntervalGcra1Violations OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of cells violating GCRA1, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpIntervalEntry 6 } atmVpIntervalRxAIS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received AIS cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpIntervalEntry 7 } atmVpIntervalTxAIS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted AIS cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals. Not supported in the first phase." ::= { atmVpIntervalEntry 8 } atmVpIntervalRxRDI OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received RDI cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpIntervalEntry 9 } atmVpIntervalTxRDI OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted RDI cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpIntervalEntry 10 } atmVpIntervalContinuityLoss OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Continuity Loss cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpIntervalEntry 11 } atmVpIntervalUAS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Unavailable Seconds, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpIntervalEntry 12 } atmVpIntervalSES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Severerly Errored Seconds, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpIntervalEntry 13 } atmVpIntervalCDC OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Amount of cells dropped in the 15 minute interval of the VP connection." ::= { atmVpIntervalEntry 14 } atmVpIntervalTotalDiscards OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of valid ATM cells discarded by the traffic policing entity. This includes cells originally received with CLP=0 and CLP=1." ::= { atmVpIntervalEntry 15 } atmVpIntervalClp0Discards OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of valid ATM cells received with CLP=0 an discarded by the traffic policing entity." ::= { atmVpIntervalEntry 16 } atmVpIntervalTotalCellOuts OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of valid ATM cells transmitted by this VPL. This includes both CLP=0 and CLP=1 cells." ::= { atmVpIntervalEntry 17 } atmVpIntervalClp0CellOuts OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of valid ATM cells transmitted with CLP=0 by this VPL." ::= { atmVpIntervalEntry 18 } atmVpIntervalTaggedOuts OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of valid ATM cells tagged by the traffic policing entity from CLP=0 to CLP=1 and transmitted by this VPL." ::= { atmVpIntervalEntry 19 } atmVpIntervalPCR OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum traffic rate encountered in the last interval of the VP connection (monitored once a second) encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpIntervalEntry 20 } atmVpIntervalSCR OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The average traffic rate during the last interval of the VP connection , encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpIntervalEntry 21 } atmVpIntervalMCR OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "MCR - The minimum traffic rate encountered in the last interval of the VP connection (monitored once a second) encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpIntervalEntry 22 } -- The ATM VP Interval Table for Performance Management -- contains various statistics -- collected by each ATM Interface/VP over the previous 24 -- hours of operation. The past 24 hours are broken into 96 -- completed 15 minute intervals. atmVpPMIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmVpPMIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ATM Vp Interval table for Performance Management." ::= { atmVpPerformance 4 } atmVpPMIntervalEntry OBJECT-TYPE SYNTAX AtmVpPMIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ATM Vp Interval table for Performance Management." INDEX { ifIndex, atmVpPMIntervalVpi, atmVpPMIntervalDir, atmVpPMIntervalNumber } ::= { atmVpPMIntervalTable 1 } AtmVpPMIntervalEntry ::= SEQUENCE { atmVpPMIntervalVpi Integer32, atmVpPMIntervalDir INTEGER, atmVpPMIntervalNumber Integer32, atmVpPMIntervalTxClp01 Gauge32, atmVpPMIntervalTxClp0 Gauge32, atmVpPMIntervalRxClp01 Gauge32, atmVpPMIntervalRxClp0 Gauge32, atmVpPMIntervalErroredCells Gauge32, atmVpPMIntervalLostCells Gauge32, atmVpPMIntervalMisinsertedCells Gauge32, atmVpPMIntervalECB Gauge32, atmVpPMIntervalSECB Gauge32, atmVpPMIntervalES Gauge32, atmVpPMIntervalSES Gauge32, atmVpPMIntervalUAS Gauge32, atmVpPMIntervalQuality INTEGER, atmVpPMIntervalLastDayQuality INTEGER } atmVpPMIntervalVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VPI of the VPL." ::= { atmVpPMIntervalEntry 1 } atmVpPMIntervalDir OBJECT-TYPE SYNTAX INTEGER {forward(2), backward(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The direction of performance management." ::= { atmVpPMIntervalEntry 2 } atmVpPMIntervalNumber OBJECT-TYPE SYNTAX Integer32 (1..96) MAX-ACCESS read-only STATUS current DESCRIPTION "A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid)." ::= { atmVpPMIntervalEntry 3 } atmVpPMIntervalTxClp01 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted CLP 0+1 cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpPMIntervalEntry 4 } atmVpPMIntervalTxClp0 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted CLP 0 cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpPMIntervalEntry 5 } atmVpPMIntervalRxClp01 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received CLP 0+1 cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpPMIntervalEntry 6 } atmVpPMIntervalRxClp0 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received CLP 0 cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpPMIntervalEntry 7 } atmVpPMIntervalErroredCells OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Errored cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpPMIntervalEntry 8 } atmVpPMIntervalLostCells OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Lost cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpPMIntervalEntry 9 } atmVpPMIntervalMisinsertedCells OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Misinserted cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpPMIntervalEntry 10 } atmVpPMIntervalECB OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of ECBs encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpPMIntervalEntry 11 } atmVpPMIntervalSECB OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of SECBs encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpPMIntervalEntry 12 } atmVpPMIntervalES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Errored Seconds, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpPMIntervalEntry 13 } atmVpPMIntervalSES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Severely Errored Seconds, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpPMIntervalEntry 14 } atmVpPMIntervalUAS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Unavailable Seconds, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals." ::= { atmVpPMIntervalEntry 15 } atmVpPMIntervalQuality OBJECT-TYPE SYNTAX INTEGER { normal(2), unacceptable(3) } MAX-ACCESS read-only STATUS current DESCRIPTION " If the number of errors per interval is superior to the atmNteUPLTCR value, the quality of service of the interval is declared as unacceptable." DEFVAL { normal } ::= { atmVpPMIntervalEntry 16} atmVpPMIntervalLastDayQuality OBJECT-TYPE SYNTAX INTEGER { normal(2), degraded(4) } MAX-ACCESS read-only STATUS current DESCRIPTION " If the number of errors per 24 hours is superior to the atmNteDPLTCR value, the quality of service of the day is declared as degraded." DEFVAL { normal } ::= { atmVpPMIntervalEntry 17} -- VP QoS Table atmVpQoSTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmVpQoSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The VP QoS table." ::= { atmVpPerformance 5 } atmVpQoSEntry OBJECT-TYPE SYNTAX AtmVpQoSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "." INDEX { ifIndex, atmVplVpi, atmVpQoSPeriodRef } ::= { atmVpQoSTable 1 } AtmVpQoSEntry ::= SEQUENCE { atmVpQoSPeriodRef INTEGER, atmVpQoSElapsedTime Integer32, atmVpQoSUAS Gauge32 } atmVpQoSPeriodRef OBJECT-TYPE SYNTAX INTEGER { currentPeriod (1), lastPeriod (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object is an index that specifies which period of time, the next 2 objects refer to. currentPeriod - the period since last systemResetAllStatsCmd received or since Start-up (if no systemResetAllStatsCmd was received since Start-up) until now. lastPeriod - the period between last two commands of systemResetAllStatsCmd. - If only one command occurred since Start-up: the period between Start-up and last command. - If no command occurred since Start-up: this period will not actually exist. In this case, he following 5 objects will be 0." ::= { atmVpQoSEntry 1 } atmVpQoSElapsedTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Elapsed Time in seconds. - for atmVpQoSPeriodRef = currentPeriod: The period since last systemResetAllStatsCmd received or since Start-up (if no systemResetAllStatsCmd was received since Start-up) until now. - for atmVpQoSPeriodRef = lastPeriod: The value of atmVpQoSElapsedTime when last systemResetAllStatsCmd was received." ::= { atmVpQoSEntry 2 } atmVpQoSUAS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of Unavailable Seconds for the reference period (atmVpQoSPeriodRef)." ::= { atmVpQoSEntry 3 } -- VP PM QoS Table atmVpPMQoSTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmVpPMQoSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The PM VP QoS table." ::= { atmVpPerformance 6 } atmVpPMQoSEntry OBJECT-TYPE SYNTAX AtmVpPMQoSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "." INDEX { ifIndex, atmVplVpi, atmVpPMQoSDirection ,atmVpPMQoSPeriodRef } ::= { atmVpPMQoSTable 1 } AtmVpPMQoSEntry ::= SEQUENCE { atmVpPMQoSDirection INTEGER, atmVpPMQoSPeriodRef INTEGER, atmVpPMQoSCLR Gauge32, atmVpPMQoSCER Gauge32, atmVpPMQoSCMR Gauge32 } atmVpPMQoSDirection OBJECT-TYPE SYNTAX INTEGER { forward (2), backward (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The direction of performance management." ::= { atmVpPMQoSEntry 1 } atmVpPMQoSPeriodRef OBJECT-TYPE SYNTAX INTEGER { currentPeriod (1), lastPeriod (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object is an index that specifies which period of time, the next 5 objects refer to. currentPeriod - the period since last systemResetAllStatsCmd received or since Start-up (if no systemResetAllStatsCmd was received since Start-up) until now. lastPeriod - the period between last two commands of systemResetAllStatsCmd. - If only one command occurred since Start-up: the period between Start-up and last command. - If no command occurred since Start-up: this period will not actually exist. In this case, he following 5 objects will be 0." ::= { atmVpPMQoSEntry 2 } atmVpPMQoSCLR OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cell Loss Ratio counter for the reference period (atmVpPMQoSPeriodRef)- defined in accordance with I.356 , in %. The value will be multipuled by 100." ::= { atmVpPMQoSEntry 3 } atmVpPMQoSCER OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cell Error Ratio counter for the reference period (atmVpPMQoSPeriodRef) defined in accordance with I.356 , in %. The value will be multipuled by 100." ::= { atmVpPMQoSEntry 4 } atmVpPMQoSCMR OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cell Misinsertion Ratio counter for the reference period (atmVpPMQoSPeriodRef) defined in accordance with I.356 , cells/sec ." ::= { atmVpPMQoSEntry 5 } --VP Shaper Statistics Table atmVpShaperStatTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmVpShaperStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ATM VP shaper statistics table." ::= { atmVpPerformance 7 } atmVpShaperStatEntry OBJECT-TYPE SYNTAX AtmVpShaperStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ATM VP shaper statistics table." INDEX { ifIndex, atmVplVpi } ::= { atmVpShaperStatTable 1 } AtmVpShaperStatEntry ::= SEQUENCE { atmVpShaperDiscarded Counter32, atmVpShaperOccupation Integer32, atmVpShaperMaxOccupation Integer32, atmVpShaperLevel INTEGER, atmVpShaperEpdDropped Counter32, atmVpShaperTotalEpdDropped Counter32 } atmVpShaperDiscarded OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Cells that were discarded in the shaper on that VPC due to buffer overflow. This counter counts till it reaches its MAX value (20 bits) and then rolls over." ::= { atmVpShaperStatEntry 1 } atmVpShaperOccupation OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Cells that are currently stored in the buffer. This parameter is limited to 20 bits." ::= { atmVpShaperStatEntry 2} atmVpShaperMaxOccupation OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The Maximum number of Cells that were stored in the buffer, since this VP was activated. This parameter is limited to 20 bits." ::= { atmVpShaperStatEntry 3} atmVpShaperLevel OBJECT-TYPE SYNTAX INTEGER { empty (1), full (2), below (3), above (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The occupation of the buffer according to a predefined threshold. empty - buffer is Empty full - buffer is Full below - buffer is Below the threshold above - buffer is Above the threshold. This is also the trigger to start EPD\PPD mechanism, if set for the VPC." ::= { atmVpShaperStatEntry 4} atmVpShaperEpdDropped OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Cells that were dropped in the shaper on that VPC due to EPD\PPD mechanism in the last second. This parameter is limited to 24 bits. Applicable for a EPD/PPD VP only." ::= { atmVpShaperStatEntry 5} atmVpShaperTotalEpdDropped OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The Total number of Cells that were dropped in the shaper on that VPC due to EPD\PPD mechanism in the last 15 minutes. This counter automatically reset itself every 15 minutes. Applicable for a EPD/PPD VP only." ::= { atmVpShaperStatEntry 6} atmVcPerformance OBJECT IDENTIFIER ::= {atmPvcPerformance 2} -- the ATM VC Current -- The ATM VC current table contains various statistics being -- collected for the current 15 minute interval. atmVcCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmVcCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ATM VC Current table." ::= { atmVcPerformance 1 } atmVcCurrentEntry OBJECT-TYPE SYNTAX AtmVcCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ATM VC Current table." INDEX { ifIndex, atmVcCurrentVpi, atmVcCurrentVci } ::= { atmVcCurrentTable 1 } AtmVcCurrentEntry ::= SEQUENCE { atmVcCurrentVpi Integer32, atmVcCurrentVci Integer32, atmVcCurrentRxCellsClp01 Gauge32, atmVcCurrentRxCellsClp0 Gauge32, atmVcCurrentGcra0Violations Gauge32, atmVcCurrentGcra1Violations Gauge32, atmVcCurrentRxAIS Gauge32, atmVcCurrentTxAIS Gauge32, atmVcCurrentRxRDI Gauge32, atmVcCurrentTxRDI Gauge32, atmVcCurrentContinuityLoss Gauge32, atmVcCurrentUAS Gauge32, atmVcCurrentSES Gauge32, atmVcCurrentCDC Gauge32, atmVcCurrentTotalDiscards Gauge32, atmVcCurrentClp0Discards Gauge32, atmVcCurrentTotalCellOuts Gauge32, atmVcCurrentClp0CellOuts Gauge32, atmVcCurrentTaggedOuts Gauge32, atmVcCurrentPCR Gauge32, atmVcCurrentSCR Gauge32, atmVcCurrentMCR Gauge32 } atmVcCurrentVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VPI of the VCL." ::= { atmVcCurrentEntry 1 } atmVcCurrentVci OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VCI of the VCL." ::= { atmVcCurrentEntry 2 } atmVcCurrentRxCellsClp01 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted cells, encountered by the VCL of this ATM interface in the current 15 minute interval." ::= { atmVcCurrentEntry 3 } atmVcCurrentRxCellsClp0 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received cells, encountered by the VCL of this ATM interface in the current 15 minute interval." ::= { atmVcCurrentEntry 4 } atmVcCurrentGcra0Violations OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of cells violating GCRA0, encountered by the VCL of this ATM interface in the current 15 minute interval." ::= { atmVcCurrentEntry 5 } atmVcCurrentGcra1Violations OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of cells violating GCRA1, encountered by the VCL of this ATM interface in the current 15 minute interval." ::= { atmVcCurrentEntry 6 } atmVcCurrentRxAIS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received AIS cells, encountered by the VCL of this ATM interface in the current 15 minute interval." ::= { atmVcCurrentEntry 7 } atmVcCurrentTxAIS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted AIS cells, encountered by the VCL of this ATM interface in the current 15 minute interval. Not Supported in the first phase." ::= { atmVcCurrentEntry 8 } atmVcCurrentRxRDI OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received RDI cells, encountered by the VCL of this ATM interface in the current 15 minute interval." ::= { atmVcCurrentEntry 9 } atmVcCurrentTxRDI OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted RDI cells, encountered by the VCL of this ATM interface in the current 15 minute interval." ::= { atmVcCurrentEntry 10 } atmVcCurrentContinuityLoss OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of loss of continuity cells, encountered by the VCL of this ATM interface in the current 15 minute interval." ::= { atmVcCurrentEntry 11 } atmVcCurrentUAS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Unavailable Seconds, encountered by the VCL of this ATM interface in the current 15 minute interval." ::= { atmVcCurrentEntry 12 } atmVcCurrentSES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Severerly Errored Seconds, encountered by the VCL of this ATM interface in the current 15 minute interval." ::= { atmVcCurrentEntry 13 } atmVcCurrentCDC OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Amount of cells dropped in the current 15 minute interval of the VC connection." ::= { atmVcCurrentEntry 14 } atmVcCurrentTotalDiscards OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of valid ATM cells discarded by the traffic policing entity. This includes cells originally received with CLP=0 and CLP=1." ::= { atmVcCurrentEntry 15 } atmVcCurrentClp0Discards OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of valid ATM cells received with CLP=0 an discarded by the traffic policing entity." ::= { atmVcCurrentEntry 16 } atmVcCurrentTotalCellOuts OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of valid ATM cells transmitted by this VPL. This includes both CLP=0 and CLP=1 cells." ::= { atmVcCurrentEntry 17 } atmVcCurrentClp0CellOuts OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of valid ATM cells transmitted with CLP=0 by this VPL." ::= { atmVcCurrentEntry 18 } atmVcCurrentTaggedOuts OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of valid ATM cells tagged by the traffic policing entity from CLP=0 to CLP=1 and transmitted by this VPL." ::= { atmVcCurrentEntry 19 } atmVcCurrentPCR OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum traffic rate encountered in the last interval of the VC connection (monitored once a second)." ::= { atmVcCurrentEntry 20 } atmVcCurrentSCR OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The average traffic rate during the last interval of the VC connection." ::= { atmVcCurrentEntry 21 } atmVcCurrentMCR OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "MCR - The minimum traffic rate encountered in the last interval of the VC connection (monitored once a second)." ::= { atmVcCurrentEntry 22 } -- The ATM VC current table for Performance Management -- which contains various statistics being -- collected for the current 15 minute interval. atmVcPMCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmVcPMCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ATM VC Current table for Performance Management." ::= { atmVcPerformance 2 } atmVcPMCurrentEntry OBJECT-TYPE SYNTAX AtmVcPMCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ATM VC Current table for Performance Management." INDEX { ifIndex, atmVcPMCurrentVpi, atmVcPMCurrentVci, atmVcPMCurrentDir } ::= { atmVcPMCurrentTable 1 } AtmVcPMCurrentEntry ::= SEQUENCE { atmVcPMCurrentVpi Integer32, atmVcPMCurrentVci Integer32, atmVcPMCurrentDir Integer32, atmVcPMCurrentTxClp01 Gauge32, atmVcPMCurrentTxClp0 Gauge32, atmVcPMCurrentRxClp01 Gauge32, atmVcPMCurrentRxClp0 Gauge32, atmVcPMCurrentErroredCells Gauge32, atmVcPMCurrentLostCells Gauge32, atmVcPMCurrentMisinsertedCells Gauge32, atmVcPMCurrentECB Gauge32, atmVcPMCurrentSECB Gauge32, atmVcPMCurrentES Gauge32, atmVcPMCurrentSES Gauge32, atmVcPMCurrentUAS Gauge32, atmVcPMCurrentIntervalQuality INTEGER, atmVcPMCurrentLastDayQuality INTEGER } atmVcPMCurrentVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VPI of the VCL." ::= { atmVcPMCurrentEntry 1 } atmVcPMCurrentVci OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VCI of the VCL." ::= { atmVcPMCurrentEntry 2 } atmVcPMCurrentDir OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The direction of Performance Management." ::= { atmVcPMCurrentEntry 3 } atmVcPMCurrentTxClp01 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted CLP 0+1 cells, encountered by the VCL of this ATM interface in the current 15 minute interval." ::= { atmVcPMCurrentEntry 4 } atmVcPMCurrentTxClp0 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted CLP 0 cells, encountered by the VCL of this ATM interface in the current 15 minute interval." ::= { atmVcPMCurrentEntry 5 } atmVcPMCurrentRxClp01 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received CLP 0+1 cells, encountered by the VCL of this ATM interface in the current 15 minute interval." ::= { atmVcPMCurrentEntry 6 } atmVcPMCurrentRxClp0 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received CLP 0 cells, encountered by the VCL of this ATM interface in the current 15 minute interval." ::= { atmVcPMCurrentEntry 7 } atmVcPMCurrentErroredCells OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of errored cells, encountered by the VCL of this ATM interface in the current 15 minute interval." ::= { atmVcPMCurrentEntry 8 } atmVcPMCurrentLostCells OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of lost cells, encountered by the VCL of this ATM interface in the current 15 minute interval." ::= { atmVcPMCurrentEntry 9 } atmVcPMCurrentMisinsertedCells OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of misinserted cells, encountered by the VCL of this ATM interface in the current 15 minute interval." ::= { atmVcPMCurrentEntry 10 } atmVcPMCurrentECB OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of ECBs encountered by the VCL of this ATM interface in the current 15 minute interval." ::= { atmVcPMCurrentEntry 11 } atmVcPMCurrentSECB OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of SECBs encountered by the VCL of this ATM interface in the current 15 minute interval." ::= { atmVcPMCurrentEntry 12 } atmVcPMCurrentES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Errored Seconds, encountered by the VCL of this ATM interface in the current 15 minute interval." ::= { atmVcPMCurrentEntry 13 } atmVcPMCurrentSES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Severely Errored Seconds, encountered by the VCL of this ATM interface in the current 15 minute interval." ::= { atmVcPMCurrentEntry 14 } atmVcPMCurrentUAS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Severely Errored Seconds, encountered by the VCL of this ATM interface in the current 15 minute interval." ::= { atmVcPMCurrentEntry 15 } atmVcPMCurrentIntervalQuality OBJECT-TYPE SYNTAX INTEGER { normal(2), unacceptable(3) } MAX-ACCESS read-only STATUS current DESCRIPTION " If the number of errors per interval is superior to the atmNteUPLTCR value, the quality of service of the interval is declared as unacceptable." DEFVAL { normal } ::= { atmVcPMCurrentEntry 16 } atmVcPMCurrentLastDayQuality OBJECT-TYPE SYNTAX INTEGER { normal(2), degraded(4) } MAX-ACCESS read-only STATUS current DESCRIPTION " If the number of errors per 24 hours is superior to the atmNteDPLTCR value, the quality of service of the day is declared as degraded." DEFVAL { normal } ::= { atmVcPMCurrentEntry 17 } -- the ATM VC Interval -- The ATM VC Interval Table contains various statistics -- collected by each ATM Interface/VC over the previous 24 -- hours of operation. The past 24 hours are broken into 96 -- completed 15 minute intervals. atmVcIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmVcIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ATM Vc Interval table." ::= { atmVcPerformance 3 } atmVcIntervalEntry OBJECT-TYPE SYNTAX AtmVcIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ATM Vc Interval table." INDEX { ifIndex, atmVcIntervalVpi, atmVcIntervalVci, atmVcIntervalNumber } ::= { atmVcIntervalTable 1 } AtmVcIntervalEntry ::= SEQUENCE { atmVcIntervalVpi Integer32, atmVcIntervalVci Integer32, atmVcIntervalNumber Integer32, atmVcIntervalRxCellsClp01 Gauge32, atmVcIntervalRxCellsClp0 Gauge32, atmVcIntervalGcra0Violations Gauge32, atmVcIntervalGcra1Violations Gauge32, atmVcIntervalRxAIS Gauge32, atmVcIntervalTxAIS Gauge32, atmVcIntervalRxRDI Gauge32, atmVcIntervalTxRDI Gauge32, atmVcIntervalContinuityLoss Gauge32, atmVcIntervalUAS Gauge32, atmVcIntervalSES Gauge32, atmVcIntervalCDC Gauge32, atmVcIntervalTotalDiscards Gauge32, atmVcIntervalClp0Discards Gauge32, atmVcIntervalTotalCellOuts Gauge32, atmVcIntervalClp0CellOuts Gauge32, atmVcIntervalTaggedOuts Gauge32, atmVcIntervalPCR Gauge32, atmVcIntervalSCR Gauge32, atmVcIntervalMCR Gauge32 } atmVcIntervalVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VPI of the VCL." ::= { atmVcIntervalEntry 1 } atmVcIntervalVci OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VCI of the VCL." ::= { atmVcIntervalEntry 2 } atmVcIntervalNumber OBJECT-TYPE SYNTAX Integer32 (1..96) MAX-ACCESS read-only STATUS current DESCRIPTION "A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid)." ::= { atmVcIntervalEntry 3 } atmVcIntervalRxCellsClp01 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted cells , encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcIntervalEntry 4 } atmVcIntervalRxCellsClp0 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcIntervalEntry 5 } atmVcIntervalGcra0Violations OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of cells violating GCRA0, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcIntervalEntry 6 } atmVcIntervalGcra1Violations OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of cells violating GCRA1, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcIntervalEntry 7 } atmVcIntervalRxAIS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received AIS cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcIntervalEntry 8 } atmVcIntervalTxAIS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted AIS cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals. Not supported in the first phase." ::= { atmVcIntervalEntry 9 } atmVcIntervalRxRDI OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received RDI cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcIntervalEntry 10 } atmVcIntervalTxRDI OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted RDI cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcIntervalEntry 11 } atmVcIntervalContinuityLoss OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Continuity Loss cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcIntervalEntry 12 } atmVcIntervalUAS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Unavailable Seconds, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcIntervalEntry 13 } atmVcIntervalSES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Severerly Errored Seconds, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcIntervalEntry 14 } atmVcIntervalCDC OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Amount of cells dropped in the 15 minute interval of the VC connection." ::= { atmVcIntervalEntry 15 } atmVcIntervalTotalDiscards OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of valid ATM cells discarded by the traffic policing entity. This includes cells originally received with CLP=0 and CLP=1." ::= { atmVcIntervalEntry 16 } atmVcIntervalClp0Discards OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of valid ATM cells received with CLP=0 an discarded by the traffic policing entity." ::= { atmVcIntervalEntry 17 } atmVcIntervalTotalCellOuts OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of valid ATM cells transmitted by this VPL. This includes both CLP=0 and CLP=1 cells." ::= { atmVcIntervalEntry 18 } atmVcIntervalClp0CellOuts OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of valid ATM cells transmitted with CLP=0 by this VPL." ::= { atmVcIntervalEntry 19 } atmVcIntervalTaggedOuts OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of valid ATM cells tagged by the traffic policing entity from CLP=0 to CLP=1 and transmitted by this VPL." ::= { atmVcIntervalEntry 20 } atmVcIntervalPCR OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum traffic rate encountered in the last interval of the VC connection (monitored once a second) encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcIntervalEntry 21 } atmVcIntervalSCR OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The average traffic rate during the last interval of the VC connection, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcIntervalEntry 22 } atmVcIntervalMCR OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "MCR - The minimum traffic rate encountered in the last interval of the VC connection (monitored once a second) encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcIntervalEntry 23 } -- The ATM VC Interval Table for Performance Management -- which contains various statistics -- collected by each ATM Interface/VC over the previous 24 -- hours of operation. The past 24 hours are broken into 96 -- completed 15 minute intervals. atmVcPMIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmVcPMIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ATM Vc Interval table for Performance Management." ::= { atmVcPerformance 4 } --atmCESAAL1StatsTable OBJECT IDENTIFIER ::= {atmVcPerformance 5} (see hybCES.txt) atmVcPMIntervalEntry OBJECT-TYPE SYNTAX AtmVcPMIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ATM Vc Interval table for Performance Management." INDEX { ifIndex, atmVcPMIntervalVpi, atmVcPMIntervalVci, atmVcPMIntervalDir, atmVcPMIntervalNumber } ::= { atmVcPMIntervalTable 1 } AtmVcPMIntervalEntry ::= SEQUENCE { atmVcPMIntervalVpi Integer32, atmVcPMIntervalVci Integer32, atmVcPMIntervalDir INTEGER, atmVcPMIntervalNumber Integer32, atmVcPMIntervalTxClp01 Gauge32, atmVcPMIntervalTxClp0 Gauge32, atmVcPMIntervalRxClp01 Gauge32, atmVcPMIntervalRxClp0 Gauge32, atmVcPMIntervalErroredCells Gauge32, atmVcPMIntervalLostCells Gauge32, atmVcPMIntervalMisinsertedCells Gauge32, atmVcPMIntervalECB Gauge32, atmVcPMIntervalSECB Gauge32, atmVcPMIntervalES Gauge32, atmVcPMIntervalSES Gauge32, atmVcPMIntervalUAS Gauge32, atmVcPMIntervalQuality INTEGER, atmVcPMIntervalLastDayQuality INTEGER } atmVcPMIntervalVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VPI of the VCL." ::= { atmVcPMIntervalEntry 1 } atmVcPMIntervalVci OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VCI of the VCL." ::= { atmVcPMIntervalEntry 2 } atmVcPMIntervalDir OBJECT-TYPE SYNTAX INTEGER {forward(2), backward(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The direction of Performance Management." ::= { atmVcPMIntervalEntry 3 } atmVcPMIntervalNumber OBJECT-TYPE SYNTAX Integer32 (1..96) MAX-ACCESS read-only STATUS current DESCRIPTION "A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid)." ::= { atmVcPMIntervalEntry 4 } atmVcPMIntervalTxClp01 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted CLP 0+1 cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcPMIntervalEntry 5 } atmVcPMIntervalTxClp0 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted CLP 0 cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcPMIntervalEntry 6 } atmVcPMIntervalRxClp01 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received CLP 0+1 cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcPMIntervalEntry 7 } atmVcPMIntervalRxClp0 OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received CLP 0 cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcPMIntervalEntry 8 } atmVcPMIntervalErroredCells OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Errored cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcPMIntervalEntry 9 } atmVcPMIntervalLostCells OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Lost cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcPMIntervalEntry 10 } atmVcPMIntervalMisinsertedCells OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Misinserted cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcPMIntervalEntry 11 } atmVcPMIntervalECB OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of ECBs encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcPMIntervalEntry 12 } atmVcPMIntervalSECB OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of SECBs encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcPMIntervalEntry 13 } atmVcPMIntervalES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Errored Seconds, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcPMIntervalEntry 14 } atmVcPMIntervalSES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Severely Errored Seconds, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcPMIntervalEntry 15 } atmVcPMIntervalUAS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Unavailable Seconds, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals." ::= { atmVcPMIntervalEntry 16 } atmVcPMIntervalQuality OBJECT-TYPE SYNTAX INTEGER { normal(2), unacceptable(3) } MAX-ACCESS read-only STATUS current DESCRIPTION " If the number of errors per interval is superior to the atmNteUPLTCR value, the quality of service of the interval is declared as unacceptable." DEFVAL { normal } ::= { atmVcPMIntervalEntry 17} atmVcPMIntervalLastDayQuality OBJECT-TYPE SYNTAX INTEGER { normal(2), degraded(4) } MAX-ACCESS read-only STATUS current DESCRIPTION " If the number of errors per 24 hours is superior to the atmNteDPLTCR value, the quality of service of the day is declared as degraded." DEFVAL { normal } ::= { atmVcPMIntervalEntry 18} -- VC QoS Table atmVcQoSTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmVcQoSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ATM VP QoS table." ::= { atmVcPerformance 6 } atmVcQoSEntry OBJECT-TYPE SYNTAX AtmVcQoSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ATM VP table." INDEX { ifIndex, atmVclVpi, atmVclVci, atmVcQoSPeriodRef } ::= { atmVcQoSTable 1 } AtmVcQoSEntry ::= SEQUENCE { atmVcQoSPeriodRef INTEGER, atmVcQoSElapsedTime Integer32, atmVcQoSUAS Gauge32 } atmVcQoSPeriodRef OBJECT-TYPE SYNTAX INTEGER { currentPeriod (1), lastPeriod (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object is an index that specifies which period of time, the next 2 objects refer to. currentPeriod - the period since last systemResetAllStatsCmd received or since Start-up (if no systemResetAllStatsCmd was received since Start-up) until now. lastPeriod - the period between last two commands of systemResetAllStatsCmd. - If only one command occurred since Start-up: the period between Start-up and last command. - If no command occurred since Start-up: this period will not actually exist. In this case, he following 5 objects will be 0." ::= { atmVcQoSEntry 1 } atmVcQoSElapsedTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Elapsed Time in seconds. - for atmVcQoSPeriodRef = currentPeriod: The period since last systemResetAllStatsCmd received or since Start-up (if no systemResetAllStatsCmd was received since Start-up) until now. - for atmVcQoSPeriodRef = lastPeriod: The value of atmVcQoSElapsedTime when last systemResetAllStatsCmd was received." ::= { atmVcQoSEntry 2 } atmVcQoSUAS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of Unavailable Seconds for the reference period (atmVcQoSPeriodRef)." ::= { atmVcQoSEntry 3 } -- VC PM QoS Table atmVcPMQoSTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmVcPMQoSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The PM VC QoS table." ::= { atmVcPerformance 7 } atmVcPMQoSEntry OBJECT-TYPE SYNTAX AtmVcPMQoSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the VC PM QoS table." INDEX { ifIndex, atmVclVpi, atmVclVci, atmVcPMQoSDirection ,atmVcPMQoSPeriodRef } ::= { atmVcPMQoSTable 1 } AtmVcPMQoSEntry ::= SEQUENCE { atmVcPMQoSDirection INTEGER, atmVcPMQoSPeriodRef INTEGER, atmVcPMQoSCLR Gauge32, atmVcPMQoSCER Gauge32, atmVcPMQoSCMR Gauge32 } atmVcPMQoSDirection OBJECT-TYPE SYNTAX INTEGER { forward(2), backward(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The direction of performance management." ::= { atmVcPMQoSEntry 1 } atmVcPMQoSPeriodRef OBJECT-TYPE SYNTAX INTEGER { currentPeriod (1), lastPeriod (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object is an index that specifies which period of time, the next 5 objects refer to. currentPeriod - the period since last systemResetAllStatsCmd received or since Start-up (if no systemResetAllStatsCmd was received since Start-up) until now. lastPeriod - the period between last two commands of systemResetAllStatsCmd. - If only one command occurred since Start-up: the period between Start-up and last command. - If no command occurred since Start-up: this period will not actually exist. In this case, he following 5 objects will be 0." ::= { atmVcPMQoSEntry 2 } atmVcPMQoSCLR OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cell Loss Ratio counter for the reference period (atmVcPMQoSPeriodRef)- defined in accordance with I.356 , in %. The value will be multipuled by 100." ::= { atmVcPMQoSEntry 3 } atmVcPMQoSCER OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cell Error Ratio counter for the reference period (atmVcPMQoSPeriodRef) defined in accordance with I.356 , in %. The value will be multipuled by 100." ::= { atmVcPMQoSEntry 4 } atmVcPMQoSCMR OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cell Miss-insertion Ratio counter for the reference period (atmVcPMQoSPeriodRef) defined in accordance with I.356 , cells/sec ." ::= { atmVcPMQoSEntry 5 } --VC Shaper Statistics Table atmVcShaperStatTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmVcShaperStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ATM VC shaper statistics table." ::= { atmVcPerformance 8 } atmVcShaperStatEntry OBJECT-TYPE SYNTAX AtmVcShaperStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ATM VC shaper statistics table." INDEX { ifIndex, atmVclVpi, atmVclVci } ::= { atmVcShaperStatTable 1 } AtmVcShaperStatEntry ::= SEQUENCE { atmVcShaperDiscarded Counter32, atmVcShaperOccupation Integer32, atmVcShaperMaxOccupation Integer32, atmVcShaperLevel INTEGER, atmVcShaperEpdDropped Counter32, atmVcShaperTotalEpdDropped Counter32 } atmVcShaperDiscarded OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Cells that were discarded in the shaper on that VCC due to buffer overflow. This counter counts till it reaches its MAX value (20 bits) and then rolls over." ::= { atmVcShaperStatEntry 1 } atmVcShaperOccupation OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Cells that are currently stored in the buffer. This parameter is limited to 20 bits." ::= { atmVcShaperStatEntry 2} atmVcShaperMaxOccupation OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The Maximum number of Cells that were stored in the buffer, since this VC was activated. This parameter is limited to 20 bits." ::= { atmVcShaperStatEntry 3} atmVcShaperLevel OBJECT-TYPE SYNTAX INTEGER { empty (1), full (2), below (3), above (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The occupation of the buffer according to a predefined threshold. empty - buffer is Empty full - buffer is Full below - buffer is Below the threshold above - buffer is Above the threshold. This is also the trigger to start EPD\PPD mechanism, if set for the VCC." ::= { atmVcShaperStatEntry 4} atmVcShaperEpdDropped OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Cells that were dropped in the shaper on that VCC due to EPD\PPD mechanism in the last second. This parameter is limited to 24 bits. Applicable for a EPD/PPD VC only." ::= { atmVcShaperStatEntry 5} atmVcShaperTotalEpdDropped OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The Total number of Cells that were dropped in the shaper on that VPC due to EPD\PPD mechanism in the last 15 minutes. This counter automatically reset itself every 15 minutes. Applicable for a EPD/PPD VC only." ::= { atmVcShaperStatEntry 6} -- New -- The agent will keep in this group the date & time corresponding to each interval. atmIntervalDateTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmIntervalDateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The agent will keep in this group the date & time corresponding to each interval." ::= {atmPerfHistory 3} atmIntervalDateEntry OBJECT-TYPE SYNTAX AtmIntervalDateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The date & time for the given interval." INDEX { atmIntervalDateInterval } ::= { atmIntervalDateTable 1 } AtmIntervalDateEntry ::= SEQUENCE { atmIntervalDateInterval Integer32, atmIntervalDateDate DisplayString, atmIntervalDateTime DisplayString } atmIntervalDateInterval OBJECT-TYPE SYNTAX Integer32 (1..96) MAX-ACCESS read-only STATUS current DESCRIPTION " The interval number defining this entry." ::= { atmIntervalDateEntry 1} atmIntervalDateDate OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The date corresponding to this interval." ::= { atmIntervalDateEntry 2} atmIntervalDateTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The time corresponding to this interval." ::= { atmIntervalDateEntry 3} --atmNte OBJECT IDENTIFIER ::= {radAtm 3} atmNteSys OBJECT IDENTIFIER ::= {atmNte 1} atmNteSysConfig OBJECT IDENTIFIER ::= {atmNteSys 1} atmNteManagerTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmNteManagerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Manager Table includes all the NMSs that receive traps from this agent. A single manager can receive traps on more than one PVC. The PVCs must be from the four allowed. The agent will set implicitly the correct ifIndex, VPI, VCI values to all relevant entries in the table when the user changes them for one of the PVCs." ::= { atmNteSysConfig 1 } atmNteManagerEntry OBJECT-TYPE SYNTAX AtmNteManagerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A single manager and the PVC for receiving traps." INDEX { atmNteManagerIP, atmNteManagerPvc} ::= { atmNteManagerTable 1 } AtmNteManagerEntry ::= SEQUENCE { atmNteManagerIP IpAddress, atmNteManagerPvc Integer32, atmNteManagerIfIndex Integer32, atmNteManagerVpi Integer32, atmNteManagerVci Integer32, atmNteManagerTrapMask Integer32, atmNteManagerRowStatus RowStatus, atmNteManagerNextHop IpAddress, atmNteManagerVlanSupport INTEGER, atmNteManagerVlanIdentifier Integer32, atmNteManagerVlanFramePriority Integer32 } atmNteManagerIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The IP address of the NMS." ::= { atmNteManagerEntry 1 } atmNteManagerPvc OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A PVC index. The range is 1..8. There are four PVCs on the User Port and four PVCs on the Network Port. The default VPI, VCI values are specified below." ::= { atmNteManagerEntry 2 } atmNteManagerIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The ATM interface index of the management port." ::= { atmNteManagerEntry 3 } atmNteManagerVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The VPI of the management VCL. Default: 0." ::= { atmNteManagerEntry 4 } atmNteManagerVci OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The VCI of the management VCL. Defaults: 32,33,34,35." ::= { atmNteManagerEntry 5 } atmNteManagerTrapMask OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The value of this attribute determines the type of traps the agent should mask and not send to this NMS. The value is differently determined for different products. There are mainly two methods: - an integer number, specifying the traps' severity. - a sum of 2**n, where n is a bit assigned to a certain masked trap group. User should consult the product specification, to find out the method employed." ::= { atmNteManagerEntry 6 } atmNteManagerRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Creation/Deletion of rows in the table." ::= {atmNteManagerEntry 7} atmNteManagerNextHop OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "This parameter is relevant to Ethernet out of band host only (PVC=10). The Next Hop IP address of the entry route." ::= { atmNteManagerEntry 8 } atmNteManagerVlanSupport OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-create STATUS current DESCRIPTION "VLAN support (Tagging). no - No support to VLAN. yes - 4 VLAN bytes will be added to the frame." ::= { atmNteManagerEntry 9} atmNteManagerVlanIdentifier OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "VLAN ID. Range is 0..4095." ::= { atmNteManagerEntry 10 } atmNteManagerVlanFramePriority OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "VLAN Frame priority.Range is 0..7." ::= { atmNteManagerEntry 11 } atmNteUPLTCR OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The Unacceptable ES Limit threshold for Performance Management." ::= {atmNteSysConfig 2} atmNteDPLTCR OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The Degraded ES Limit threshold for Performance Management." ::= {atmNteSysConfig 3} atmNteSysLogClearAll OBJECT-TYPE SYNTAX INTEGER { off(2), clear(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting the variable to clear(3) removes all entries in the Log Buffer of the agent. The agent will immediately reset the variable to off(2)." ::= {atmNteSysConfig 4} atmNteUSESLTCR OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The Unacceptable SES Limit threshold for Performance Management." ::= {atmNteSysConfig 5} atmNteDSESLTCR OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The Degraded ES Limit threshold for Performance Management." ::= {atmNteSysConfig 6} atmNteProtection OBJECT IDENTIFIER ::= { atmNteSysConfig 8 } atmNteProtectionMode OBJECT-TYPE SYNTAX INTEGER { off (1), mspOn (2), pathOn (3), mspUniOn (4), mspOneToN (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Protection Mode. MspOn - Multiplex section protection. pathOn - High order path protection. mspUniOn - Multiplex section Uni-directional protection. mspOneToN - Multiplex section protection." ::= { atmNteProtection 1 } atmNteProtectionWorkingLink OBJECT-TYPE SYNTAX INTEGER { trunk1(2), trunk2(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selects the working link when atmNteProtectionMode is off." ::= { atmNteProtection 2 } atmNteProtectionSwitchLink OBJECT-TYPE SYNTAX INTEGER { off(1), forceSwitch(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "ForceSwitch - will force Switching from the working link to the backup link. Afterwards the agent will set atmNteProtectionSwitchLink back to off(1). atmNteProtectionMode must be either mspOn or pathOn." ::= { atmNteProtection 3 } atmNteConfOam OBJECT IDENTIFIER ::= { atmNteSysConfig 9 } atmNteConfOamSupport OBJECT-TYPE SYNTAX INTEGER { intermediate(1), segmentTermination(2), endToEndTermination(3), vpEndToEndVcSegment(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "OAM support mode, which determines the device location in a segment wise." ::= { atmNteConfOam 1 } atmNteConfOamTransmission OBJECT IDENTIFIER ::= { atmNteConfOam 2 } atmNteConfOamAIS OBJECT-TYPE SYNTAX INTEGER { none(1), user(2), network(3), both(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Defines if a F4 segment OAM cell is transmitted due to problems in the other port, i.e. physical layer alarm or F4 defect. This is valid only when the ACE101 has ATM UNI interfaces in both sides and is configured for 'Non-Intrusive' mode. none - AIS is not sent to any of the ports. user - F4 AIS will be sent toward the user when defect is detected in the network port. network - F4 AIS will be sent toward the network when defect is detected in the user port. both - F4 AIS will be sent toward the network when defect is detected in the user port and toward the user when defect is detected in the network port." ::= { atmNteConfOamTransmission 1 } atmNteConfOamRDI OBJECT-TYPE SYNTAX INTEGER { none(1), user(2), network(3), both(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Defines if an F4 OAM RDI cell is transmitted due to physical layer problems in the port (in addition to F4 RDI cells transmitted due to ATM layer problems). The type of F4 RDI (Segment or End-to-End) is according to the ACE-101 OAM mode. For example, If it is enabled for Network port, then physical layer defect will initiate the transmission of F4 RDI cell back to the trunk." ::= { atmNteConfOamTransmission 2 } atmNteConfOamAddressing OBJECT IDENTIFIER ::= { atmNteConfOam 3 } atmNteConfLoopbackAddMode OBJECT-TYPE SYNTAX INTEGER{ off(1), on(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Loopback addressing mode. on - will enable loopback addressing. off - will disable loopback addressing." ::= { atmNteConfOamAddressing 1 } atmNteConfLoopbackSourceAdd OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2..20)) MAX-ACCESS read-write STATUS current DESCRIPTION " Loopback source address. This field is relevant when atmNteConfOamAddMode is on." ::= { atmNteConfOamAddressing 2 } --OAM Table atmNteConfOamIfTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmNteConfOamIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "OAM support per ATM interface." ::= { atmNteConfOam 4 } atmNteConfOamIfEntry OBJECT-TYPE SYNTAX AtmNteConfOamIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "." INDEX { ifIndex } ::= { atmNteConfOamIfTable 1 } AtmNteConfOamIfEntry ::= SEQUENCE { atmNteConfOamIfAisRdi INTEGER } atmNteConfOamIfAisRdi OBJECT-TYPE SYNTAX INTEGER { off(1), on (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter controls the generation of F4/F5 AIS and RDI due to lower order problems such as physical layer problems. For AIS: Defines if F4/F5 AIS cell is transmitted due to problems such as physical layer alarm or F4/F5 defect. This is applicable for all ports . off - Problems in this port will not trigger F4/F5 AIS transmition to the ajacent port (e.g. from USER to NETWORK) of a VPC/VCC. on - Problems in this port will trigger F4/F5 AIS transmition to the ajacent port (e.g. from USER to NETWORK) of a VPC/VCC. For RDI: Defines if F4/F5 RDI cell will be transmitted due to physical layer problems in that port (in addition to F4/F5 RDI cells transmitted due to ATM layer problems). For example, If it is enabled for Network port, then physical layer defect will initiate the transmission of F4/F5 RDI cell back to the trunk. The type of F4/F5 (Segment or End-to-End) is according to the configuration of the VPC/VCC." ::= { atmNteConfOamIfEntry 1 } atmNteConfCAC OBJECT IDENTIFIER ::= { atmNteSysConfig 10 } atmNteConfCACMode OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "CAC support mode. For ACE2002, the following are the applicable values: disable(1), enable(2), 10 - 1000." ::= { atmNteConfCAC 1 } atmNteHostIfTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmNteHostIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Host IP interface table." ::= { atmNteSysConfig 11 } atmNteHostIfEntry OBJECT-TYPE SYNTAX AtmNteHostIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "." INDEX { atmNteHostPvcIndex } ::= { atmNteHostIfTable 1 } AtmNteHostIfEntry ::= SEQUENCE { atmNteHostPvcIndex Integer32, atmNteHostIP IpAddress, atmNteHostMask IpAddress, atmNteHostAtmIfIndex Integer32, atmNteHostVpi Integer32, atmNteHostVci Integer32, atmNteHostRowStatus RowStatus, atmNteHostRdnVpi Integer32, atmNteHostRdnVci Integer32 } atmNteHostPvcIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A PVC index. The range is 1..8. There are four PVCs on the User Port and four PVCs on the Network Port." ::= { atmNteHostIfEntry 1 } atmNteHostIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "The host interface IP address." ::= { atmNteHostIfEntry 2 } atmNteHostMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "The host interface subnet mask." ::= { atmNteHostIfEntry 3 } atmNteHostAtmIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "ATM interface index. Will be 1 for user port, and 2 for network port." ::= { atmNteHostIfEntry 4 } atmNteHostVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "VPI of the PVC connected to that host interface." ::= { atmNteHostIfEntry 5 } atmNteHostVci OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "VCI of the PVC connected to that host interface." ::= { atmNteHostIfEntry 6 } atmNteHostRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Creation/Deletion of rows in the table." ::= { atmNteHostIfEntry 7 } atmNteHostRdnVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The VPI of the redundant management VCL. This parameter is applicable only if atmNteRdnManagement=enable(3). " ::= { atmNteHostIfEntry 8 } atmNteHostRdnVci OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The VCI of the redundant management VCL. This parameter is applicable only if atmNteRdnManagement=enable(3). " ::= { atmNteHostIfEntry 9 } atmNteShaperMode OBJECT-TYPE SYNTAX INTEGER { normal (1), group (2), aggregate (3), vpInbandMng (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Shaper Mode. vpInbandMng - Vcc within a Vp for management." ::= { atmNteSysConfig 12 } atmNteOutputRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Aggregate shaping output rate in Cells per Seconds units. Default value is the Network port rate." ::= { atmNteSysConfig 13 } atmNteTosMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "TOS Mode." ::= { atmNteSysConfig 14 } atmNteTosMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter determines the seqence of bits that will be used for TOS. This parameter is applicable only if atmNteTosMode = enable. Valid only for IP-TOS process." ::= { atmNteSysConfig 15 } atmNteTosHighPriority OBJECT-TYPE SYNTAX OCTET STRING (SIZE(8)) MAX-ACCESS read-write STATUS current DESCRIPTION "Priorities options are High or Low. High priority will be represented by bit = 1. Low priority will be represented by bit = 0. Each TOS value will be represented by the bit location. For example, the string for TOS 2, 9, 15 with High priority, will be: |0000 0000|... ...|0000 0000|1000 0010|0000 0100| ...98 7654 3210 (Bit #) 8 ... 3 2 1 (Byte #)." ::= { atmNteSysConfig 16 } atmNtePlugAndPlayActivity OBJECT-TYPE SYNTAX INTEGER { disable (1), offline (2), online (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Activity control for Manager Plug And Play. disable - disable the feature. offline - Automatic learn IP address into offline memory. online - Automatic learn IP address into online memory. " ::= { atmNteSysConfig 17 } atmNteSlotUsage OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), user (2), network (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to ace2002. Slot 2 might be configured as user slot or as network slot." ::= { atmNteSysConfig 18 } atmNteConnectionsMaxNumber OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), max1024 (2), max2048 (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The MAX number of connections supported by system. Setting this parameter will affect the number of MAX intervals supported. This parameter will affect the system only after reset. Changing this parameter from high value to a low value, will be accepted by agent only if the actual used connection <= the desired connection Max number. Applicable to ace2002. " ::= { atmNteSysConfig 19 } atmNteDefaultVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Default Vpi for management." ::= { atmNteSysConfig 20 } atmNteDefaultVci OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Default Vci for management." ::= { atmNteSysConfig 21 } atmNteReservedVpi OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "Internal use VPI, where shaperMode=vpInbandMng." ::= { atmNteSysConfig 22 } atmNteRdnManagement OBJECT-TYPE SYNTAX INTEGER { disabled (2), enabled (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The redundancy management status." ::= { atmNteSysConfig 23 } atmNtePlugAndPlayIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-write STATUS current DESCRIPTION "The ifIndex of the Plug and Play VCC." ::= { atmNteSysConfig 24 } atmNteLoopbackTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The Loopback state timeout in minutes. A value of zero means no timeout (for ever). Default is 5 min." ::= { atmNteSysConfig 25 } atmNteOamTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmNteOamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is a static table, which is created by agent once upon initialization. The created entries are actually, only the supported OAM features. This table enables addition of new features by adding new entries rather than adding scalar parameters. An OAM feature is defined by the indexes values combination." ::= { atmNteSysConfig 26 } atmNteOamEntry OBJECT-TYPE SYNTAX AtmNteOamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the OAM table. Each entry in this table will indicate a special OAM." INDEX {atmNteOamMode, atmNteOamCellType, atmNteOamLevel} ::= { atmNteOamTable 1 } AtmNteOamEntry ::= SEQUENCE { atmNteOamMode INTEGER, atmNteOamCellType INTEGER, atmNteOamLevel INTEGER, atmNteOamEnable INTEGER } atmNteOamMode OBJECT-TYPE SYNTAX INTEGER { endToEnd (1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The OAM cell path. endToEnd(1) - the entire path." ::= { atmNteOamEntry 1 } atmNteOamCellType OBJECT-TYPE SYNTAX INTEGER { aisAndRdi (1), loopback (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a unique Indication Signal. aisAndRdi(1) - Alarm Indication Signal (AIS) and Remote Defect Indication (RDI) cell. loopback(2) - Loopback cell." ::= { atmNteOamEntry 2 } atmNteOamLevel OBJECT-TYPE SYNTAX INTEGER { -- f4 (2), f5 (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The level of the OAM cell. -- f4 (2) - VP level, f5 (3) - VC level." ::= { atmNteOamEntry 3 } atmNteOamEnable OBJECT-TYPE SYNTAX INTEGER { disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter determines if the specified OAM cells will be enabled." ::= { atmNteOamEntry 4 } atmNteDefaultLoopbackThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The Default OAM Loopback Failure Threshold value that will be used for configuration." ::= { atmNteSysConfig 27 } atmNteSysInfo OBJECT IDENTIFIER ::= {atmNteSys 2} atmNteIdTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmNteIdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The IDs of the cards and of the system." ::= { atmNteSysInfo 1 } atmNteIdEntry OBJECT-TYPE SYNTAX AtmNteIdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "." INDEX { atmNteIdIndex} ::= { atmNteIdTable 1 } AtmNteIdEntry ::= SEQUENCE { atmNteIdIndex Integer32, atmNteUnitId Integer32, atmNteUnitVersion DisplayString, atmNteCardType INTEGER } atmNteIdIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "An Index of the Unit ID table. The following units have IDs in this table: 1 - System 2 - ATM Board 3 - User Card 4 - Trunk 1 card 5 - Trunk 2 card 6 - Shaper 7 - Clock Unit 8 - Slot 1 card 9 - Slot 2 card 10 - Slot 3 card 11 - Slot 4 card 12 - Fan1. 13 - Fan2." ::= { atmNteIdEntry 1 } atmNteUnitId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The ID of the Unit. For index = 6, the id will describe the validity of a shaper in the system: 0 - Shaper Not exist 1 - Shaper exist. For index = 7, the id will describe the validity of a clock in the system: 0 - Clock Not exist 1 - Clock exist. 2- Clock exist but failed. For index = 12,13 the id will describe the functionality of a FAN1 : 0 - OK 1 - Failed." ::= { atmNteIdEntry 2 } atmNteUnitVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Hardware and Software version of the module." ::= { atmNteIdEntry 3 } atmNteCardType OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), sc13mR155 (2), st13sR155 (3), st13lR155 (4), utpR155 (5), cxBncR155 (6), e3 (7), t3 (8), e1 (9), e1Ltu (10), fc13lR155 (11), fc13lhR155 (12), fc15lhR155 (13), fc13lE3 (14), fc13lhE3 (15), fc15lhE3 (16), fc13lT3 (17), fc13lhT3 (18), fc15lhT3 (19), t1 (20), eth (21), ethE1CesBnc (22), ethE1CesRj45 (23), ethT1CesRj45 (24), e1CesRj45 (25), e1CesBnc (26), t1CesRj45 (27), e14Ces (28), e14CesRj45 (29), t14CesRj45 (30), hdlc4port (31), hdlcE14CesBnc (32), hdlcE14CesRj45 (33), hdlcT14CesRj45 (34), e1Rj45 (35), e1Bnc (36), ethE14CesBnc (37), ethE14CesRj45 (38), ethT14CesRj45 (39), hdlc1portHssi (40), hdlcHssiE14CesBnc (41), hdlcHssiE14CesRj45 (42), hdlcHssiT14CesRj45 (43), e14ImaRj45 (44), e14ImaBnc (45), t14ImaRj45 (46), ethE3CesBnc (47), ethT3CesBnc (48), smSf1R155 (49), smSf2R155 (50), sc13sR155 (51), sc13lR155 (52), utp25 (53), sc13lhR155 (54), sc15lhR155 (55), sc13ljR155 (56), sc13lhjR155 (57), sc15lhjR155 (58), e18Ces (59), e18CesRj45 (60), t18CesRj45 (61), sc13mR622 (62), -- st13sR622 (63), -- st13lR622 (64), -- utpR622 (65), -- cxBncR622 (66), -- fc13lR622 (67), -- fc13lhR622 (68), -- fc15lhR622 (69), -- smSf1R622 (70), -- smSf2R622 (71), -- sc13sR622 (72), sc13lR622 (73), sc13lhR622 (74), sc15lhR622 (75), fr4Port (76), t3j (77), fr1Port (78), hdlc1Port (79), sc13mR155D (80), sc13lR155D (81), fc13lR155D (82), st13lR155D (83), sc13lhR155D (84), fc13lhR155D (85), st13lhR155D (86), e18ImaBnc (87), e18ImaRj45 (88), t18ImaRj45 (89), fEthUtp (90), fEthSm (91), fEthMm (92), e14ImaRj45CfgMode (93), e14ImaBncCfgMode (94), t14ImaRj45CfgMode (95), sc13mR155R (96), sc13lR155R (97), fc13lR155R (98), st13lR155R (99), sc13lhR155R (100), fc13lhR155R (101), st13lhR155R (102), empty (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "The card type." ::= { atmNteIdEntry 4 } atmSysPSunits OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of power supply units." ::= { atmNteSysInfo 2 } atmSysPSunitsInUse OBJECT-TYPE SYNTAX INTEGER { ps1(2), ps2(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The main power supply in this unit." ::= { atmNteSysInfo 3 } atmSysFanUnits OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of fan units." ::= { atmNteSysInfo 4 } atmSysNetPrts OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of network ports." ::= { atmNteSysInfo 5 } atmSysNetPrtInUse OBJECT-TYPE SYNTAX INTEGER { trunk1(2), trunk2(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The network port in use." ::= { atmNteSysInfo 6 } atmNteBridgingMode OBJECT-TYPE SYNTAX INTEGER { accessOnly(1), accessAndSwitching (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Bridging mode can be one of the following: ATM <> Ethernet - Bridging is between the Ethernet port and the ATM port (there is no bridging between VCs). ATM <> Ethernet + ATM - Bridging is done both between the Ethernet port and the ATM port and also between VCs." ::= { atmNteSysInfo 7} atmSysStats OBJECT IDENTIFIER ::= { atmNteSysInfo 8 } atmSysCurrentCdc OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Seconds in which cells dropped was occured in the current 15 minutes interval." ::= { atmSysStats 1 } atmSysIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmSysIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The system level Interval table." ::= { atmSysStats 2 } atmSysIntervalEntry OBJECT-TYPE SYNTAX AtmSysIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "." INDEX { atmSysIntervalNumber } ::= { atmSysIntervalTable 1 } AtmSysIntervalEntry ::= SEQUENCE { atmSysIntervalNumber Integer32, atmSysIntervalCdc Gauge32 } atmSysIntervalNumber OBJECT-TYPE SYNTAX Integer32 (1..96) MAX-ACCESS read-only STATUS current DESCRIPTION "A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid)." ::= { atmSysIntervalEntry 1 } atmSysIntervalCdc OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Seconds in which cells dropped was occured in 15 minutes interval." ::= { atmSysIntervalEntry 2 } atmNteEventType OBJECT-TYPE SYNTAX INTEGER { ps1NotActive (3), ps1Active (4), ps2NotActive (5), ps2Active (6), heatAlarmOff (7), heatAlarmOn (8), inputAlarm1Off (9), inputAlarm1On (10), inputAlarm2Off (11), inputAlarm2On (12), inputAlarm3Off (13), inputAlarm3On (14), inputAlarm4Off (15), inputAlarm4On (16), fan1Ok (17), fan1Fail (18), fan2Ok (19), fan2Fail (20), invalidLogin (21), validLogin (22), powerFailure (23) } MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter identifies the event. On - the problem exist. Off - the problem not exist. InvalidLogin - Invalid login on local console. CorrectLogin - Successful login operation." ::= { atmNteSysInfo 9 } atmNteIntervalMaxNumber OBJECT-TYPE SYNTAX Integer32 (1..96) MAX-ACCESS read-only STATUS current DESCRIPTION "The MAX number of connections intervals supported by system. This parameter value is a function of atmNteConnectionsMaxNumber parameter. This parameter should affect the threshold values selected by user. Applicable to ace2002." ::= { atmNteSysInfo 10 } atmNteAlarmType OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), ais(2), rdi(3), continuityLoss(4), loopback(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the type of the alarm." ::= { atmNteSysInfo 11 } atmNteLevel OBJECT-TYPE SYNTAX INTEGER { vp(2), vc(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the ATM level." ::= { atmNteSysInfo 12 } atmNteConnectionsNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies a quantity of connections." ::= { atmNteSysInfo 13 } --atmNtePrt OBJECT IDENTIFIER ::= {atmNte 2} -- Changed atmNteLoopback OBJECT IDENTIFIER ::= {atmNtePrt 2} -- The loopback test consists of inserting special OAM cells. This test is started and stopped -- upon operator request (by using MIB item atmVpConfLoopbackAdminStatus). -- There are two tables per VP and two tables per VC: the measurements of the current 15 minutes, -- and the measurement of the last 96 periods of 15 minutes. atmLoopbackVpTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmLoopbackVpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains parameters for an OAM VP loopback test." ::= {atmNteLoopback 1 } atmLoopbackVpEntry OBJECT-TYPE SYNTAX AtmLoopbackVpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table atmLoopbackVpTable." INDEX {atmLoopbackVpIfIndex,atmLoopbackVpVpi} ::= {atmLoopbackVpTable 1} AtmLoopbackVpEntry ::= SEQUENCE { atmLoopbackVpIfIndex Integer32, atmLoopbackVpVpi Integer32, atmLoopbackVpOperStatus INTEGER, atmLoopbackVpCDV Integer32, atmLoopbackVpAverageDelay Integer32, atmLoopbackVpMaxDelay Integer32, atmLoopbackVpMinDelay Integer32, atmLoopbackVpErrSessions Integer32 } atmLoopbackVpIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The interface index of the ATM layer." ::= {atmLoopbackVpEntry 1} atmLoopbackVpVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VPI of the OAM VPL." ::= {atmLoopbackVpEntry 2} atmLoopbackVpOperStatus OBJECT-TYPE SYNTAX INTEGER { noActive(1), inProgress(2), failed(3), endSuccessfully(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "-noActive(1) means that the loopback test has not been activated for this VP. -inProgress(2) means that the test has been activated and there is currently no problem. -failed(3) means there was problem during the test or after having stopped it -endSuccessfully(4) means that the test was stopped and all was OK." ::= {atmLoopbackVpEntry 3} atmLoopbackVpCDV OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cell Delay Variation for this sampling." ::= {atmLoopbackVpEntry 4} atmLoopbackVpAverageDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " Average delay without including lost cells." ::= {atmLoopbackVpEntry 5} atmLoopbackVpMaxDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum delay without including lost cells." ::= {atmLoopbackVpEntry 6} atmLoopbackVpMinDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum delay." ::= {atmLoopbackVpEntry 7} atmLoopbackVpErrSessions OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Errored Sessions. Will be updated once in 5 seconds." ::= {atmLoopbackVpEntry 8} atmLoopbackVcTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmLoopbackVcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains parameters for an OAM VC loopback test." ::= {atmNteLoopback 2 } atmLoopbackVcEntry OBJECT-TYPE SYNTAX AtmLoopbackVcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {atmLoopbackVcIfIndex,atmLoopbackVcVpi,atmLoopbackVcVci} ::= {atmLoopbackVcTable 1} AtmLoopbackVcEntry ::= SEQUENCE { atmLoopbackVcIfIndex Integer32, atmLoopbackVcVpi Integer32, atmLoopbackVcVci Integer32, atmLoopbackVcOperStatus INTEGER, atmLoopbackVcCDV Integer32, atmLoopbackVcAverageDelay Integer32, atmLoopbackVcMaxDelay Integer32, atmLoopbackVcMinDelay Integer32, atmLoopbackVcErrSessions Integer32 } atmLoopbackVcIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The interface index of the ATM layer." ::= {atmLoopbackVcEntry 1} atmLoopbackVcVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VPI of the OAM VCL." ::= {atmLoopbackVcEntry 2} atmLoopbackVcVci OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VCI of the OAM VCL." ::= {atmLoopbackVcEntry 3} atmLoopbackVcOperStatus OBJECT-TYPE SYNTAX INTEGER { noActive(1), inProgress(2), failed(3), endSuccessfully(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "-noActive(1) means that the loopback test has not been activated for this VP. -inProgress(2) means that the test has been activated and there is currently no problem. -failed(3) means there was problem during the test or after having stopped it -endSuccessfully(4) means that the test was stopped and all was OK." ::= {atmLoopbackVcEntry 4} atmLoopbackVcCDV OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cell Delay Variation for this sampling." ::= {atmLoopbackVcEntry 5} atmLoopbackVcAverageDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " Average delay without including lost cells." ::= {atmLoopbackVcEntry 6} atmLoopbackVcMaxDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum delay without including lost cells." ::= {atmLoopbackVcEntry 7} atmLoopbackVcMinDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum delay." ::= {atmLoopbackVcEntry 8} atmLoopbackVcErrSessions OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Errored Sessions. Will be updated once in 5 seconds." ::= {atmLoopbackVcEntry 9} -- Entirely New atmLoopbackVpIvlTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmLoopbackVpIvlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains parameters for an OAM VP loopback test, according interval number." ::= {atmNteLoopback 3 } atmLoopbackVpIvlEntry OBJECT-TYPE SYNTAX AtmLoopbackVpIvlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { atmLoopbackVpIvlIfIndex, atmLoopbackVpIvlVpi, atmLoopbackVpIvlIvl } ::= { atmLoopbackVpIvlTable 1} AtmLoopbackVpIvlEntry ::= SEQUENCE { atmLoopbackVpIvlIfIndex Integer32, atmLoopbackVpIvlVpi Integer32, atmLoopbackVpIvlIvl Integer32, atmLoopbackVpIvlOperStatus INTEGER, atmLoopbackVpIvlCDV Integer32, atmLoopbackVpIvlAverageDelay Integer32, atmLoopbackVpIvlMaxDelay Integer32, atmLoopbackVpIvlMinDelay Integer32, atmLoopbackVpIvlErrSessions Integer32 } atmLoopbackVpIvlIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The interface index of the ATM layer." ::= { atmLoopbackVpIvlEntry 1} atmLoopbackVpIvlVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VPI of the OAM VPL." ::= { atmLoopbackVpIvlEntry 2} atmLoopbackVpIvlIvl OBJECT-TYPE SYNTAX Integer32(1..96) MAX-ACCESS read-only STATUS current DESCRIPTION "The relevant interval number." ::= { atmLoopbackVpIvlEntry 3} atmLoopbackVpIvlOperStatus OBJECT-TYPE SYNTAX INTEGER { noActive(1), inProgress(2), failed(3), endSuccessfully(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "-noActive(1) means that the loopback test has not been activated for this VP during this interval. -inProgress(2) has no meaning for an ended interval. -failed(3) means there was problem during the test or after having stopped it -endSuccessfully(4) means that the test was OK." ::= { atmLoopbackVpIvlEntry 4} atmLoopbackVpIvlCDV OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cell Delay Variation for this interval." ::= { atmLoopbackVpIvlEntry 5} atmLoopbackVpIvlAverageDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " Average delay without including lost cells for this interval." ::= { atmLoopbackVpIvlEntry 6} atmLoopbackVpIvlMaxDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum delay without including lost cells for this interval." ::= { atmLoopbackVpIvlEntry 7} atmLoopbackVpIvlMinDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum delay for this interval." ::= {atmLoopbackVpIvlEntry 8} atmLoopbackVpIvlErrSessions OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Errored Sessions. Will be updated once in 5 seconds." ::= {atmLoopbackVpIvlEntry 9} atmLoopbackVcIvlTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmLoopbackVcIvlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains parameters for an OAM VC loopback test." ::= {atmNteLoopback 4 } atmLoopbackVcIvlEntry OBJECT-TYPE SYNTAX AtmLoopbackVcIvlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {atmLoopbackVcIvlIfIndex, atmLoopbackVcIvlVpi, atmLoopbackVcIvlVci, atmLoopbackVcIvlIvl } ::= {atmLoopbackVcIvlTable 1} AtmLoopbackVcIvlEntry ::= SEQUENCE { atmLoopbackVcIvlIfIndex Integer32, atmLoopbackVcIvlVpi Integer32, atmLoopbackVcIvlVci Integer32, atmLoopbackVcIvlIvl Integer32, atmLoopbackVcIvlOperStatus INTEGER, atmLoopbackVcIvlCDV Integer32, atmLoopbackVcIvlAverageDelay Integer32, atmLoopbackVcIvlMaxDelay Integer32, atmLoopbackVcIvlMinDelay Integer32, atmLoopbackVcIvlErrSessions Integer32 } atmLoopbackVcIvlIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The interface index of the ATM layer." ::= {atmLoopbackVcIvlEntry 1} atmLoopbackVcIvlVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VPI of the OAM VCL." ::= {atmLoopbackVcIvlEntry 2} atmLoopbackVcIvlVci OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VCI of the OAM VCL." ::= {atmLoopbackVcIvlEntry 3} atmLoopbackVcIvlIvl OBJECT-TYPE SYNTAX Integer32(1..96) MAX-ACCESS read-only STATUS current DESCRIPTION "The relevant interval number." ::= {atmLoopbackVcIvlEntry 4} atmLoopbackVcIvlOperStatus OBJECT-TYPE SYNTAX INTEGER { noActive(1), inProgress(2), failed(3), endSuccessfully(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "-noActive(1) means that the loopback test has not been activated for this VC during this interval. -inProgress(2) has no meaning per interval. -failed(3) means there was problem for this test during this interval. -endSuccessfully(4) means that the test was OK." ::= {atmLoopbackVcIvlEntry 5} atmLoopbackVcIvlCDV OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cell Delay Variation for this interval." ::= {atmLoopbackVcIvlEntry 6} atmLoopbackVcIvlAverageDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " Average delay without including lost cells." ::= {atmLoopbackVcIvlEntry 7} atmLoopbackVcIvlMaxDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum delay without including lost cells." ::= {atmLoopbackVcIvlEntry 8} atmLoopbackVcIvlMinDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum delay." ::= {atmLoopbackVcIvlEntry 9} atmLoopbackVcIvlErrSessions OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Errored Sessions. Will be updated once in 5 seconds." ::= {atmLoopbackVcIvlEntry 10} atmNtePM OBJECT IDENTIFIER ::= {atmNtePrt 3} atmVpPmTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmVpPmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains parameters for VP performance monitoring." ::= {atmNtePM 1 } atmVpPmEntry OBJECT-TYPE SYNTAX AtmVpPmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {atmVpPmIfIndex,atmVpPmVpi} ::= {atmVpPmTable 1} AtmVpPmEntry ::= SEQUENCE { atmVpPmIfIndex Integer32, atmVpPmVpi Integer32, atmVpPmAdminStatus INTEGER, atmVpPmDirection INTEGER, atmVpPmBlockSize Integer32, atmVpPmRowStatus RowStatus, atmVpPmSink INTEGER, atmVpPmSource INTEGER } atmVpPmIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The interface index of the ATM layer." ::= {atmVpPmEntry 1} atmVpPmVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VPI of the Performance Monitoring VPL." ::= {atmVpPmEntry 2} atmVpPmAdminStatus OBJECT-TYPE SYNTAX INTEGER { up (2), down(3), listenToActivationCells (4), originateActivationCells (5) } MAX-ACCESS read-create STATUS current DESCRIPTION "up(2) - Activate PM. down(3) - Deactivate PM. listenToActivationCells(4) - . originateActivationCells(5) - ." ::= {atmVpPmEntry 3} atmVpPmDirection OBJECT-TYPE SYNTAX INTEGER { source(2), destination(3), bidirectional(4) } MAX-ACCESS read-create STATUS current DESCRIPTION "The direction of PM." ::= {atmVpPmEntry 4} atmVpPmBlockSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Valid block sizes (in cells): 128, 256, 512, 1024, 2048, 4096, 8192, 16384, 32768." ::= {atmVpPmEntry 5} atmVpPmRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Creation/Deletion of rows in the table." ::= {atmVpPmEntry 6} atmVpPmSink OBJECT-TYPE SYNTAX INTEGER { off (1), fwd (2), fwdAndBwdReport(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "off (1) - Deactivate PM. fwd (2) - Activate Forward PM only. fwdAndBwdReport(3) - Activate Forward PM and Backward reporting." ::= {atmVpPmEntry 7} atmVpPmSource OBJECT-TYPE SYNTAX INTEGER { off (1), fwd (2), fwdAndBwdReport(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "off (1) - Deactivate PM. fwd (2) - Activate Forward PM only. fwdAndBwdReport(3) - Activate Forward PM and Backward reporting." ::= {atmVpPmEntry 8} atmVcPmTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmVcPmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains parameters for VC performance monitoring." ::= {atmNtePM 2 } atmVcPmEntry OBJECT-TYPE SYNTAX AtmVcPmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {atmVcPmIfIndex,atmVcPmVpi,atmVcPmVci} ::= {atmVcPmTable 1} AtmVcPmEntry ::= SEQUENCE { atmVcPmIfIndex Integer32, atmVcPmVpi Integer32, atmVcPmVci Integer32, atmVcPmAdminStatus INTEGER, atmVcPmDirection INTEGER, atmVcPmBlockSize Integer32, atmVcPmRowStatus RowStatus, atmVcPmSink INTEGER, atmVcPmSource INTEGER } atmVcPmIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The interface index of the ATM layer." ::= {atmVcPmEntry 1} atmVcPmVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VPI of the Performance Monitoring VCL." ::= {atmVcPmEntry 2} atmVcPmVci OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VCI of the PM VCL." ::= {atmVcPmEntry 3} atmVcPmAdminStatus OBJECT-TYPE SYNTAX INTEGER { up (2), down(3), listenToActivationCells (4), originateActivationCells (5) } MAX-ACCESS read-create STATUS current DESCRIPTION "up(2) - Activate PM. down(3) - Deactivate PM. listenToActivationCells(4) - . originateActivationCells(5) - ." ::= {atmVcPmEntry 4} atmVcPmDirection OBJECT-TYPE SYNTAX INTEGER { source(2), destination(3), bidirectional(4) } MAX-ACCESS read-create STATUS current DESCRIPTION "The direction of PM." ::= {atmVcPmEntry 5} atmVcPmBlockSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Valid block sizes (in cells): 128, 256, 512, 1024, 2048, 4096, 8192, 16384, 32768." ::= {atmVcPmEntry 6} atmVcPmRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Creation/Deletion of rows in the table." ::= {atmVcPmEntry 7} atmVcPmSink OBJECT-TYPE SYNTAX INTEGER { off (1), fwd (2), fwdAndBwdReport(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "off (1) - Deactivate PM. fwd (2) - Activate Forward PM only. fwdAndBwdReport(3) - Activate Forward PM and Backward reporting." ::= {atmVcPmEntry 8} atmVcPmSource OBJECT-TYPE SYNTAX INTEGER { off (1), fwd (2), fwdAndBwdReport(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "off (1) - Deactivate PM. fwd (2) - Activate Forward PM only. fwdAndBwdReport(3) - Activate Forward PM and Backward reporting." ::= {atmVcPmEntry 9} atmGenSystem OBJECT IDENTIFIER ::= {atmGen 2} --atmGenModules OBJECT IDENTIFIER ::= {atmGen 3} located in ace2002.txt atmGenSysGen OBJECT IDENTIFIER ::= {atmGenSystem 1} -- The self test table atmGenSysSelfTestTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmGenSysSelfTestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table containing the results of the initial testing of the device." ::= { atmGenSysGen 1 } atmGenSysSelfTestEntry OBJECT-TYPE SYNTAX AtmGenSysSelfTestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {atmGenSysSelfTestIndex} ::= {atmGenSysSelfTestTable 1} AtmGenSysSelfTestEntry ::= SEQUENCE { atmGenSysSelfTestIndex Integer32, atmGenSysSelfTestResult DisplayString } atmGenSysSelfTestIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A running index for the table." ::= { atmGenSysSelfTestEntry 1} atmGenSysSelfTestResult OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The results of the initial testing of the device." ::= { atmGenSysSelfTestEntry 2} -- The Log clear all atmGenSysLogClearAll OBJECT-TYPE SYNTAX INTEGER { off(2),clear(3)} MAX-ACCESS read-write STATUS current DESCRIPTION "Setting the variable to clear(3) removes all entries in the Log Buffer of the agent. The agent will immediately reset the variable to off(2)." ::= { atmGenSysGen 2} -- The Log table atmGenSysLogTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmGenSysLogEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A copy of the log buffer." ::= { atmGenSysGen 3 } atmGenSysLogEntry OBJECT-TYPE SYNTAX AtmGenSysLogEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {atmGenSysLogIndex} ::= {atmGenSysLogTable 1} AtmGenSysLogEntry ::= SEQUENCE { atmGenSysLogIndex Integer32, atmGenSysLogMessage DisplayString } atmGenSysLogIndex OBJECT-TYPE SYNTAX Integer32 (1..2048) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the log buffer." ::= { atmGenSysLogEntry 1} atmGenSysLogMessage OBJECT-TYPE SYNTAX DisplayString (SIZE(80)) MAX-ACCESS read-only STATUS current DESCRIPTION "The log buffer entry message text." ::= { atmGenSysLogEntry 2} -- Set to default configuration atmGenSysSetDefaultConfg OBJECT-TYPE SYNTAX INTEGER { off(2), on(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "When set to on(3), the agent will set all the configuration parameters to their default values. The variable is then reset to off(2) by the agent. The agent must be reset for the default configuration to apply." ::= {atmGenSysGen 4} -- A Cross Reference table for connections between tables. atmGenSysCxRefTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmGenSysCxRefEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A Cross Reference table. The table maintains an index of an object which is also the table index, and a counter that indicates how many times this object was referenced. When using this table for more than one referenced table, which uses the same range of indexes, then the index should be shifted by a unique offset per table. In ACE2002 this table is used for TD and for FR Desc. Thus, the index for FR Descriptor is: FR Descriptor index + offset. The offset is described in the ACE2002 NMS SRS." ::= {atmGenSysGen 5} atmGenSysCxRefEntry OBJECT-TYPE SYNTAX AtmGenSysCxRefEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The entries will be added by the agent upon an entry addition in the referenced tables (TD table, FR Descriptor etc.)" INDEX { atmGenSysCxRefIndex } ::= { atmGenSysCxRefTable 1 } AtmGenSysCxRefEntry ::= SEQUENCE { atmGenSysCxRefIndex Integer32, atmGenSysCxRefCounter Gauge32 } atmGenSysCxRefIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index specifies an entry in the table of the object." ::= { atmGenSysCxRefEntry 1 } atmGenSysCxRefCounter OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter counts the number of references that have been made to the object ." ::= { atmGenSysCxRefEntry 2 } -- Traps -- System Layer Traps atmAceStatusChange NOTIFICATION-TYPE OBJECTS {agnLed,agnIndication} STATUS current DESCRIPTION "The trap is sent every time there is a change in the state of one of the LEDs." ::= { atmNteEvents 1 } atmAceAlarmTrap NOTIFICATION-TYPE OBJECTS {atmInterfaceAlarmStatus} STATUS current DESCRIPTION "The trap is sent whenever there is a transition from a no alarm state to a state with at least one active alarm. An active alarm state exists if: 1) The atmInterfaceActiveAlarms vector is different than 0. 2) The atmNteAlarmVpTable contains entries. 3) The atmNteAlarmVcTable contains entries. The trap is also sent when a transition into the no alarm state occurs. The second variable will be atmInterfaceActiveAlarms to indicate the kind of the alarm. The trap is not sent more than once in a 10 second interval." ::= { atmNteEvents 2 } atmAceModuleChangeTrap NOTIFICATION-TYPE OBJECTS {ifIndex} STATUS current DESCRIPTION "The trap is sent every time a module is changed (Hot swapping). The second variable will be atmNteCardType to indicate the type of card that was inserted. The value empty(255) indicates that a card was taken out." ::= { atmNteEvents 3 } atmAceRedundancyTrap NOTIFICATION-TYPE OBJECTS {ifIndex } STATUS current DESCRIPTION "The trap is sent upon change in link as a result of redundancy. The ifIndex parameter indicates the current active link." ::= { atmNteEvents 4 } atmAceSystemTrap NOTIFICATION-TYPE OBJECTS { atmNteEventType, agnLed, alarmSeverity } STATUS current DESCRIPTION "This trap alerts of major problems in the device." ::= { radSysAtmEvents 6 } -- Alarms Traps atmAceAlarmLOS NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates Loss Of Signal." ::= { radSysAtmEvents 16 } atmAceAlarmLOF NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates Loss Of Frame." ::= { radSysAtmEvents 17 } atmAceAlarmLCD NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates Loss of Cell Delineation." ::= { radSysAtmEvents 18 } atmAceAlarmSLM NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates Signal Line Mismatch." ::= { radSysAtmEvents 19 } atmAceAlarmLOP NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates Loss of Pointer." ::= { radSysAtmEvents 20 } atmAceAlarmLineAIS NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates Line AIS." ::= { radSysAtmEvents 21 } atmAceAlarmPathAIS NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates Path AIS." ::= { radSysAtmEvents 22 } atmAceAlarmLineRDI NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates Line RDI." ::= { radSysAtmEvents 23 } atmAceAlarmPathRDI NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates Path RDIand Path RAI(Yellow) for DS1 interfaces." ::= { radSysAtmEvents 24 } atmAceAlarmSectionBIP NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates Section Bit Interleave Parity." ::= { radSysAtmEvents 25 } atmAceAlarmLineBIP NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates Line Bit Interleave Parity." ::= { radSysAtmEvents 26 } atmAceAlarmPathBIP NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates Path Bit Interleave Parity." ::= { radSysAtmEvents 27 } atmAceAlarmLineFEBE NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates Line Far End Block Error." ::= { radSysAtmEvents 28 } atmAceAlarmPathFEBE NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates Path Far End Block Error." ::= { radSysAtmEvents 29 } atmAceAlarmPlcpLOF NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates T3 PLCP Loss Of Frame." ::= { radSysAtmEvents 30 } atmAceAlarmPlcpYELLOW NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates T3 Plcp Yellow." ::= { radSysAtmEvents 31 } atmAceAlarmPlcpBIP NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates T3 Plcp Bit Interleave Parity." ::= { radSysAtmEvents 32 } atmAceAlarmPlcpFEBE NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates T3 Plcp Far End Block Error." ::= { radSysAtmEvents 33 } atmAceAlarmPlcpP1P2 NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates T3 Plcp Parity errors in P1/P2 bytes." ::= { radSysAtmEvents 34 } atmAceAlarmUAS NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap is sent upon UAS start or end per port." ::= { radSysAtmEvents 35 } atmAceAlarmCluster NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, atmNteAlarmType, atmNteLevel } STATUS current DESCRIPTION "This trap is sent upon atmNteAlarmType start or end, for a cluster of VPs/VCs (according to atmNteLevel) with the same alarm on the same physical port. This trap replaces sending the same alarm for a big quantity (the quantity described in the product specification document) of VPs/VCs in order to prevent flooding the NMS and the network with traps." ::= { radSysAtmEvents 36 } atmAceHwFailure NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap is sent upon HW failure per port." ::= { radSysAtmEvents 37 } -- VP Layer Traps -- atmVplVpi have MAX-ACCESS "not-accessible" -- and cannot be referenced from NOTIFICATION-TYPE clause -- in SMIV2 so they where removed from following caluses. -- Dovi Korngut (28/6/00). atmAceAlarmVpContinuityLoss NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates Loss of Continuity Check on a VP Connection." ::= { radSysAtmEvents 40 } atmAceAlarmVpAISReception NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates AIS Reception on a VP Connection." ::= { radSysAtmEvents 41 } atmAceAlarmVpRDIReception NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates RDI Reception on a VP Connection." ::= { radSysAtmEvents 42 } atmAceAlarmVpErroredCells NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates Errored Cells on a VP Connection reported by PM." ::= { radSysAtmEvents 43 } atmAceAlarmVpLostCells NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates Lost Cells on a VP Connection reported by PM." ::= { radSysAtmEvents 44 } atmAceAlarmVpMisinsertedCells NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates Misinserted Cells on a VP Connection reported by PM." ::= { radSysAtmEvents 45 } atmAceAlarmVpUAS NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap is sent upon UAS start or end per VP." ::= { radSysAtmEvents 46 } atmAceAlarmVpLoopback NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap is sent upon OAM LoopBack fail status per VP." ::= { radSysAtmEvents 47 } atmAceAlarmVpGCRAViolation NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates GCRA violation on a VP Connection reported by UPC device." ::= { radSysAtmEvents 48 } -- VC Layer Traps -- atmVclVpi and atmVclVci have MAX-ACCESS "not-accessible" -- and cannot be referenced from NOTIFICATION-TYPE clause -- in SMIV2 so they where removed from following caluses. -- Dovi Korngut (28/6/00). atmAceAlarmVcContinuityLoss NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates Loss of Continuity Check on a VC Connection." ::= { radSysAtmEvents 56 } atmAceAlarmVcAISReception NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates AIS Reception on a VC." ::= { radSysAtmEvents 57 } atmAceAlarmVcRDIReception NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates RDI Reception on a VC Connection." ::= { radSysAtmEvents 58 } atmAceAlarmVcErroredCells NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates Errored Cells on a VC Connection reported by PM." ::= { radSysAtmEvents 59 } atmAceAlarmVcLostCells NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates Lost Cells on a VC Connection reported by PM." ::= { radSysAtmEvents 60 } atmAceAlarmVcMisinsertedCells NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates Misinserted Cells on a VC Connection reported by PM." ::= { radSysAtmEvents 61 } atmAceAlarmVcUnexpectedCell NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates an unexpected cell from user or network port." ::= { radSysAtmEvents 62 } atmAceAlarmVcUAS NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap is sent upon UAS start or end per VC." ::= { radSysAtmEvents 63 } atmAceAlarmVcLoopback NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap is sent upon OAM LoopBack fail status per VC." ::= { radSysAtmEvents 64 } atmAceAlarmVcGCRAViolation NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates GCRA violation on a VC Connection reported by UPC device." ::= { radSysAtmEvents 65 } -- number 80 and up are saved for IMA traps -- -- file :v:\doc\rdv\mib\ver470\atm\hybces.txt -- -- ************************* -- file : hybCES.txt -- -- available for ACE20. --Version: 1.0 --Date: 10/11/97 --By: Ilana Schvetz --File: v:\doc\rdv\mib\ver470\atm\hybCES.txt -- Last Update: 08-Mar-01 By Ilana Schvetz -- Copyright 1996 RAD Data Communications, Ltd. -- All Rights Reserved. -- ******************************************************* -- Protocol CES Vcls statistics -- ******************************************************* --atmGen OBJECT IDENTIFIER ::= { radAtm 2 } --atmPerfHistory OBJECT IDENTIFIER ::= { atmGen 1 } --atmPvcPerformance OBJECT IDENTIFIER ::= { atmPerfHistory 2 } --atmVcPerformance OBJECT IDENTIFIER ::= { atmPvcPerformance 2 } atmCESAAL1StatsTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmCESAAL1StatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " This table shows statistics of the structured Circuit-Emulation connections." ::= { atmVcPerformance 5 } atmCESAAL1StatsEntry OBJECT-TYPE SYNTAX AtmCESAAL1StatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "defines an entry in the atmCESAAL1StatsTable" INDEX { ifIndex, atmVclVpi, atmVclVci } ::= { atmCESAAL1StatsTable 1} AtmCESAAL1StatsEntry ::= SEQUENCE { atmCESAAL1SeqErrors Counter32, atmCESAAL1HdrErrors Counter32, atmCESAAL1PointerReframes Counter32, atmCESAAL1BufUnderflows Counter32, atmCESAAL1BufOverflows Counter32 } atmCESAAL1SeqErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "number of cells discarded due to wrong sequence number " ::= { atmCESAAL1StatsEntry 1 } atmCESAAL1HdrErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "number of cells discarded due to bad AAL1 header error. this include correctable and uncorrectable CRC, plus bad parity. " ::= { atmCESAAL1StatsEntry 2 } atmCESAAL1PointerReframes OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "number of events in which the AAL1 reassembler found that an SDT pointer isn't where it is expected, and the pointer must be reacquired. " ::= { atmCESAAL1StatsEntry 3 } atmCESAAL1BufUnderflows OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "number of buffer underflows events. " ::= { atmCESAAL1StatsEntry 4 } atmCESAAL1BufOverflows OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "number of buffer overflows events. " ::= { atmCESAAL1StatsEntry 5 } -- -- file :v:\doc\rdv\mib\ver480\atm\confvctable.txt -- -- file : ConfVcTable.txt -- --Version: 1.0 --Date: 12.11.97 --By: Ilana Schvetz --File: v:\doc\rdv\mib\ver480\atm\ConfVcTable.txt --Last Update: 30-Sep-01 by Ilana. -- ******************************************************* -- Configuration Vc Table -- ******************************************************* --atmNte OBJECT IDENTIFIER ::= { radAtm 3 } --atmNtePrt OBJECT IDENTIFIER ::= { atmNte 2 } --atmNtePrtConfig OBJECT IDENTIFIER ::= { atmNtePrt 1 } atmNteConfVcTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmNteConfVcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ATM VC configuration table. The table is an extension to the atmVclTable of RFC-1695." ::= { atmNtePrtConfig 4 } atmNteConfVcEntry OBJECT-TYPE SYNTAX AtmNteConfVcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ATM VC configuration table. ifIndex of the ATM layer." INDEX { ifIndex , atmVclVpi, atmVclVci} ::= { atmNteConfVcTable 1 } AtmNteConfVcEntry ::= SEQUENCE { atmConfVcPolicing INTEGER, atmConfVcCCAdminStatus INTEGER, atmConfVcLoopbackAdminStatus INTEGER, atmConfVcLoopbackSinkAddress OCTET STRING, atmConfVcCongestionControl OCTET STRING, atmConfVcCCDirection INTEGER, atmConfVcCreationTime DateAndTime, atmConfVcOamSupport INTEGER, atmConfVcCCActivationCtrl INTEGER, atmConfVcCCOperStatus INTEGER, atmConfVcLoopbackTraffic INTEGER, atmConfVcLoopbackFailureInd INTEGER, atmConfVcLoopbackFailureThreshold Integer32, atmConfVcOamDirection INTEGER } atmConfVcPolicing OBJECT-TYPE SYNTAX INTEGER { none(1), police(2), monitor(3), shaping(4), policingAndShaping(5), notApplicable(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Policing method desired for this VCL." ::= { atmNteConfVcEntry 1 } atmConfVcCCAdminStatus OBJECT-TYPE SYNTAX INTEGER { up(2), down(3), source(4), -- agent send Oam CC cells sink(5), -- agent check received Oam CC cells listenToActivationCells (6), originateActivationCells(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "up(2) - Activate Continuity Check (CC). down(3) - Deactivate CC. source(4) - Activate OAM CC(Continuity Check) of local agent ( start sending Oam cells to the remote side ). sink(5) - Activate CC of remote agent ( start receiving Oam cells from remote side ). listenToActivationCells (6) - Passive listener till gets an activation request originateActivationCells(7) - Sands Activation cell according to atmConfVcCCDirection." ::= {atmNteConfVcEntry 2} atmConfVcLoopbackAdminStatus OBJECT-TYPE SYNTAX INTEGER { up(2), down(3), llid(4), segment(5), endToEnd(6), segmentLlid(7), endToEndLlid(8) } MAX-ACCESS read-write STATUS current DESCRIPTION "up(2) - Start loopback OAM cells. down(3) - Stop sending loopback OAM cells. For ace2002: up(2) - Transmitting LB cells with llid all ones (i.e. FFFF..FF) down(3) - Not transmitting LB cells. llid(4) - Transmitting LB cells with llid indicated in the address field. segment(5) - Transmitting Segment LB cells with llid all ones. endToEnd(6) - Transmitting End to End LB cells with llid all ones. segmentLlid(7) - Transmitting Segment LB cells with llid indicated in the address field. endToEndLlid(8) - Transmitting LB cells with llid indicated in the address field. This parameter value might be in conflict with atmConfVcOamSupport value, since this parameter is for LB, while atmConfVcOamSupport is for any other OAM cells." ::= {atmNteConfVcEntry 3} atmConfVcLoopbackSinkAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "Destination address. For ace101: 2 bytes are used. For ace2002: 16 bytes are used." ::= {atmNteConfVcEntry 4} atmConfVcCongestionControl OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Each bit indicates a selection of one option as the following description. All combinations are possible and legal. The codes are: 1 - EPD 2 - CLP 4 - EFCI. For ace2002: 1 - Packet Discard." ::= {atmNteConfVcEntry 5} atmConfVcCCDirection OBJECT-TYPE SYNTAX INTEGER { both (2), source(4), sink (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "both(2) - Agent send OAM CC cells and check receivev OAM CC cells source(4)- Agent send OAM CC cells. sink(5) - Agent checks received OAM CC cells." ::= {atmNteConfVcEntry 6} atmConfVcCreationTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "A date-time in which the VC was created." ::= { atmNteConfVcEntry 7 } atmConfVcOamSupport OBJECT-TYPE SYNTAX INTEGER { intermediate(1), segmentTermination(2), endToEndTermination(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "OAM support mode, which determines the device location in a segment wise." ::= { atmNteConfVcEntry 8 } atmConfVcCCActivationCtrl OBJECT-TYPE SYNTAX INTEGER { manual(1), activator(2), listener(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "manual(1) - CC Activation process is disable activator(2) - ACE-101 initiate CC Activation process listener(3) - ACE-101 wait to CC Activation request from remote side." ::= { atmNteConfVcEntry 9 } atmConfVcCCOperStatus OBJECT-TYPE SYNTAX INTEGER { initial(1), up(2), down(3), source(4), -- agent send Oam CC cells sink(5), -- agent check received Oam CC cells both (8), timeout (9), denied (10), conflict (11), manual (12) } MAX-ACCESS read-only STATUS current DESCRIPTION " initial (1) - The CC activation process is not started. up (2) - Continuity Check (CC) activated. down (3) - CC deactivated. source (4) - OAM CC(Continuity Check) of local agent activated. sink (5) - OAM CC of remote agent activated. both (8) - OAM CC of local and remote agents activation. timeout (9) - Timeout occured on receiving answer from the remote agent. denied (10) - CC activation process rejected by remote agent. conflict (11) - local and remote sides requested activation simultaneously. manual (12) - OAM CC of local agent activated manually. " ::= { atmNteConfVcEntry 10 } atmConfVcLoopbackTraffic OBJECT-TYPE SYNTAX INTEGER { off(2), on(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter has both command and status meanings: off(2) - Set to 'Off' will Stop traffic loop. Getting this value means that the loop is not running. on (3) - Set to 'On' will start traffic loop. Getting this value means that the loop is currently running." ::= {atmNteConfVcEntry 11} atmConfVcLoopbackFailureInd OBJECT-TYPE SYNTAX INTEGER { disabled(2), segmentAis(3), segmentRdi(4), segmentAisAndRdi(5), endToEndAis(6), endToEndRdi(7), endToEndAisAndRdi(8) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object allows user to define the Indication that will be created upon a LB cell failure. disabled(2) - no indication will be created. segmentAis(3) - will cause Tx of a segment AIS. segmentRdi(4) - will cause Tx of a segment RDI. segmentAisAndRdi(5) - will cause Tx of a segment AIS & RDI. endToEndAis(6) - will cause Tx of an End to End AIS. endToEndRdi(7) - will cause Tx of an End to End RDI. endToEndAisAndRdi(8) - will cause Tx of an End to End AIS & RDI. Default: disabled(2)." ::= {atmNteConfVcEntry 12} atmConfVcLoopbackFailureThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The number of the LB failures before starting transmission of the Indication defined by atmConfVcLoopbackFailureInd. Range: 1..16. Default: 1." ::= {atmNteConfVcEntry 13} atmConfVcOamDirection OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), downStream (2), upStream (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The direction of OAM cell insertion. downStream(2) - The OAM cell will be inserted in downStream. upStream(3) - The OAM cell will be inserted in upStream." ::= {atmNteConfVcEntry 14} END -- -- file :v:\doc\rdv\mib\ver475\atm\ace20.txt -- -- ************************* -- file : Ace20_v3.mib -- ACE20-MIB DEFINITIONS ::= BEGIN --Title: RAD's ACE20 PRODUCT MIB --Version: 3.0 --Date: 01/06/99 --By: Eyal Sadovsky & Isac Winter --File: v:\doc\rdv\mib\ver475\atm\Ace20.txt --Last Update: 5-Feb-02 by Yig'al Hachmon -- -- IMPORTS -- OBJECT-TYPE , OBJECT-IDENTITY , -- Integer32 , Counter32 FROM SNMPv2-SMI -- TimeStamp, -- TEXTUAL-CONVENTION, DisplayString FROM SNMPv2-TC -- ifIndex FROM SNMPv2-TC -- atmVclVpi, atmVclVci, -- AtmTrafficDescrParamIndex FROM ATM-MIB -- frPVCEndptDLCIIndex FROM FRNETSERV-MIB; -- TRAP-TYPE FROM RFC-1215 -- radAtm, agnLed, agnIndication FROM RAD-GEN-MIB; --RowStatus ::= TEXTUAL-CONVENTION -- STATUS current -- DESCRIPTION -- "." -- SYNTAX INTEGER { -- active(1), -- notInService(2), -- notReady(3), -- createAndGo(4), -- createAndWait(5), -- destroy(6) -- } atmSu OBJECT IDENTIFIER ::= { radAtm 4 } -- RAD ATM Service Unit atmSuSystem OBJECT IDENTIFIER ::= { atmSu 1 } -- agent system level configuration -- *********************************************************************** -- RAD System Software Group -- -- This table contains software verions parameters. -- *********************************************************************** atmSuSystemSwOperStatus OBJECT-TYPE SYNTAX INTEGER { disable (1) , enable (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This value indicates if tftp_write operation (for downloading software from an external host) is allowed by the agent. " DEFVAL { enable } ::= { atmSuSystem 1 } atmSuSystemSwSwitchVersionsCmd OBJECT-TYPE SYNTAX INTEGER { notActive (1) , active (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This command is used to switch beetween software versions stored in the flash. setting this value to active will reset the agent and re-activate it with the new version ( only if new version is valid). on get-request this value will be always notActive. " ::= { atmSuSystem 2 } -- ******************************************************* -- agent Alarms definitions - two alarms table defined : -- 1. History Table which hold a buffer contains history events. -- 2. Mandatory Table hold information of all mandatory alarms -- -- the following alarms ifIndex defined : -- 0. system alarms -- 1. physical DS1 alarms - T1/E1 layer -- 2. ATM alarms -- 5. ATM-DXI / Frame-Relay alarms -- ******************************* atmSuSystemHistoryAlrTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmSuSystemHistoryAlrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "buffer contain history buffer of agent alarms." ::= { atmSuSystem 3 } atmSuSystemHistoryAlrEntry OBJECT-TYPE SYNTAX AtmSuSystemHistoryAlrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Agent alarm history list entry." INDEX { atmSuSystemHistoryAlrIndex } ::= { atmSuSystemHistoryAlrTable 1} AtmSuSystemHistoryAlrEntry ::= SEQUENCE { atmSuSystemHistoryAlrIndex Integer32, atmSuSystemHistoryAlrIfIndex Integer32, atmSuSystemHistoryAlrDescription DisplayString, atmSuSystemHistoryAlrStatus INTEGER, atmSuSystemHistoryAlrOccurrenceTime DisplayString } atmSuSystemHistoryAlrIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique number to identify an entry in the history alarm table." ::= { atmSuSystemHistoryAlrEntry 1 } atmSuSystemHistoryAlrIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This value indicates the port on which the alarms occured. configuration(system) alarms have port index equal to 0. " ::= { atmSuSystemHistoryAlrEntry 2 } atmSuSystemHistoryAlrDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute is a text description of the alarm. The alarm descipion include alarm code and alarm text." ::= { atmSuSystemHistoryAlrEntry 3 } atmSuSystemHistoryAlrStatus OBJECT-TYPE SYNTAX INTEGER { on (1), off (2), event (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the status of the alarm." ::= { atmSuSystemHistoryAlrEntry 4 } atmSuSystemHistoryAlrOccurrenceTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This value indicates the time of the occurrence of the event that caused this alarm. " ::= { atmSuSystemHistoryAlrEntry 5 } atmSuSystemClearHistoryAlrListCmd OBJECT-TYPE SYNTAX INTEGER { off(1), on (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to ON, enforce a clear operation on the agent history event buffer . On reading, attribute will always get status 'off' ." ::= { atmSuSystem 4 } atmSuSystemCurrentAlrTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmSuSystemCurrentAlrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "table which contains all alarms Currently active ( status ON ) in the agent." ::= { atmSuSystem 5 } atmSuSystemCurrentAlrEntry OBJECT-TYPE SYNTAX AtmSuSystemCurrentAlrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Agent alarm list entry." INDEX { atmSuSystemCurrentAlrIndex } ::= { atmSuSystemCurrentAlrTable 1} AtmSuSystemCurrentAlrEntry ::= SEQUENCE { atmSuSystemCurrentAlrIndex Integer32, atmSuSystemCurrentAlrIfIndex Integer32, atmSuSystemCurrentAlrDescription DisplayString } atmSuSystemCurrentAlrIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique number to identify an entry in the Current alarms table." ::= { atmSuSystemCurrentAlrEntry 1 } atmSuSystemCurrentAlrIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This value indicates the port on which the alarms occured. configuration alarms have port index equal to 0. " ::= { atmSuSystemCurrentAlrEntry 2 } atmSuSystemCurrentAlrDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute is a text description of the alarm. The alarm descipion include alarm code and alarm text." ::= { atmSuSystemCurrentAlrEntry 3 } -- ******************************************************* -- Agent Config Managers Group -- ******************************************************* atmSuSystemILMICommunity OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Community string for ILMI requests. 10 chars." ::= { atmSuSystem 6 } atmSuSystemTrapMaxManagers OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of managers that can be registered for receiving traps and sending requests." DEFVAL { 10 } ::= { atmSuSystem 7 } -- ******************************************************* -- Agent AAL1 / AAL2 selection -- ******************************************************* atmSuSystemAalSelection OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), aal2 (2), aal1 (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Select ATM adaptation layers AAL1 or AAL2 Applicable for LA-140" ::= { atmSuSystem 8 } -- ******************************************************* -- Agent u-Law selection -- ******************************************************* atmSuSystemCodingLaw OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), aLaw (2), uLaw (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the Method/Law for decoding/encoding the voice information. aLaw (2) is the standard Law for E1 links. uLaw (3) is the standard Law for T1 links. Coding law is applicable for all the ports in the system" ::= { atmSuSystem 9 } -- ******************************************************* -- Agent ISDN selection -- ******************************************************* atmSuSystemISDNDataLinkActivation OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), nonPermanent (2), permanent (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates data link aactivation for all ISDN ports in the system. nonPermanent (2) = non permanent data link activation permanent (3) = permanent data link activation" ::= { atmSuSystem 10 } -- ******************************************************* -- Agent ATM Jitter Buffer -- ******************************************************* atmSuSystemJitterBuffer OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The field is set in ms and sets the jitter buffer size. The jitter buffer adapts the size of the LA140 traffic to the cdv (cell delay variation) of the ATM network." ::= { atmSuSystem 11 } -- **************************************************************** -- **************************************************************** -- agent ports definitions -- **************************************************************** -- **************************************************************** atmSuPort OBJECT IDENTIFIER ::= { atmSu 2 } -- agent ports definitions -- ******************************** -- global data port definitions -- ******************************** -- -- the following table uses parameters which define the physical data port -- and they are the same for FR and ATM-DXI interfaces -- atmSuPortDataCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmSuPortDataCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Data Port global configuration table. this table include parametes which are common to the physical port and not depend on whether the port interface is Frame-Relay or ATM-DXI." ::= { atmSuPort 1 } atmSuPortDataCnfgEntry OBJECT-TYPE SYNTAX AtmSuPortDataCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "the entries at this table describes the configuration of the Data-Port." INDEX { ifIndex } ::= { atmSuPortDataCnfgTable 1} AtmSuPortDataCnfgEntry ::= SEQUENCE { atmSuPortDataApplication INTEGER, atmSuPortDataRate INTEGER, atmSuPortDataDCD INTEGER, atmSuPortDataMode INTEGER, atmSuPortDataCRC INTEGER, atmSuPortDataClock INTEGER, atmSuPortDataMaxNoOfConns Integer32, atmSuPortDataConfNoOfConns Integer32, atmSuPortDataIdleCode Integer32 } atmSuPortDataApplication OBJECT-TYPE SYNTAX INTEGER { frameRelay (1), atmDxi (2), bridgedEthernet (3), smdsDxi (4), -- for future use aal1Stream (5), routedEthernet (6), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the protocol application which runs above the physical port." ::= { atmSuPortDataCnfgEntry 1 } atmSuPortDataRate OBJECT-TYPE SYNTAX INTEGER { r64KBps (1), r128KBps (2), r192KBps (3), r256KBps (4), r320KBps (5), r384KBps (6), r448KBps (7), r512KBps (8), r576KBps (9), r640KBps (10), r704KBps (11), r768KBps (12), r832KBps (13), r896KBps (14), r960KBps (15), r1024KBps (16), r1088KBps (17), r1152KBps (18), r1216KBps (19), r1280KBps (20), r1344KBps (21), r1408KBps (22), r1472KBps (23), r1536KBps (24), r1544network (25), -- take the clock from the T1 network clock for ACE-20T/ACE-2T1 r1600KBps (26), r1664KBps (27), r1728KBps (28), r1792KBps (29), r1856KBps (30), r1920KBps (31), r1984KBps (32), r2048KBps (33), r2048network (34), -- take the clock from the E1 network clock for ACE-20E/ACE-2E1 notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the operation rate of the port. AmcdT1 / Ace-20T allowes rates up to 1536KBps ( options 1-12 ), while AmcdE1 / Ace-20E allowes all options. " ::= { atmSuPortDataCnfgEntry 2 } atmSuPortDataDCD OBJECT-TYPE SYNTAX INTEGER { off (1), on (2), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates if the bits CtsCd( Clear-to-send Carry-detect) are being checked. In AMCD CTS is also checked. off - ignore DCD signal on - obey DCD signal" ::= { atmSuPortDataCnfgEntry 3 } atmSuPortDataMode OBJECT-TYPE SYNTAX INTEGER { nrzi (1), nrz (2), notApplicable (255) } MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This attribute indicates the port mode of sampling data physical. " ::= { atmSuPortDataCnfgEntry 4 } atmSuPortDataCRC OBJECT-TYPE SYNTAX INTEGER { cRC16 (1), cRC32 (2), noCRC (3), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the type of CRC checking on receiving/transmiting frames. " ::= { atmSuPortDataCnfgEntry 5 } atmSuPortDataClock OBJECT-TYPE SYNTAX INTEGER { dce (1), edce (2), -- for future use dte (3), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the clock using for synchronization for the data port. " ::= { atmSuPortDataCnfgEntry 6 } atmSuPortDataMaxNoOfConns OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " this object indicates the maximum number of cross-connect connections allowed beetween the ATM port and the Data Port identified by IfIndex. " ::= { atmSuPortDataCnfgEntry 7 } atmSuPortDataConfNoOfConns OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " this object indicates the configured number of cross-connect connections exist beetween the ATM port and the Data Port identified by IfIndex. " ::= { atmSuPortDataCnfgEntry 8 } atmSuPortDataIdleCode OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION " This attribute is applicable only for application aal1Stream. It indicates the value to be transmitted whenever the port is idle. " ::= { atmSuPortDataCnfgEntry 9 } -- ************************************************************* -- agent physical network definitions ( T1/E1 interface ) -- ************************************************************* atmSuPortDs1 OBJECT IDENTIFIER ::= { atmSuPort 2 } -- DS1 definitions -- -- this table include expansion to the config table in rfc1406 -- atmSuPortDs1CnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmSuPortDs1CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " This table include expansion configuration to the DS1 physical port." ::= { atmSuPortDs1 1 } atmSuPortDs1CnfgEntry OBJECT-TYPE SYNTAX AtmSuPortDs1CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "the entries at this table describes the configuration of the agent physical." INDEX { ifIndex } ::= { atmSuPortDs1CnfgTable 1} AtmSuPortDs1CnfgEntry ::= SEQUENCE { atmSuPortDs1CnfgRxSensitivity INTEGER, atmSuPortDs1CnfgLBO INTEGER, atmSuPortDs1CnfgRestoreTime INTEGER } atmSuPortDs1CnfgRxSensitivity OBJECT-TYPE SYNTAX INTEGER { s12dB (1), -- for E1 Interface s30dB (2), -- for T1/E1 Interface s36dB (3) -- for T1 Interface } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute is the rx line sensetivity parameter used only for T1/CSU and E1/LTU interfaces." ::= { atmSuPortDs1CnfgEntry 1 } atmSuPortDs1CnfgLBO OBJECT-TYPE SYNTAX INTEGER { txGain0db(1), txGain7dot5db (2), -- txGain15db (3), -- for T1/CSU Interface txGain22dot5db (4), -- len0p133ft (5), -- len133p266ft (6), -- len266p399ft (7), -- for T1/DSU Interface len399p533ft (8), -- len533p655ft (9), -- unbalanceE1 (10), -- for E1 Interface balanceE1 (11) -- } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute is the line-Build-Out indicates sensitivity of the DS1 interface. The user can define if the agent will be CSU or DSU (for T1 only) by choosing the right option. On E1 interface this is done by hardware, so this parameter cannot be written. " ::= { atmSuPortDs1CnfgEntry 2 } atmSuPortDs1CnfgRestoreTime OBJECT-TYPE SYNTAX INTEGER { ccittE1 (1), restoreT1secFast (2), restoreT10sec62411 (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Determines the time passing from the disappearance of the loss of synchronization condition (red alarm) to the restoration of normal service. The options 1secFast(2) and 10sec62411(3) for E1 interfaces are proprietary implementation of the T1 standard to the E1 interface." ::= { atmSuPortDs1CnfgEntry 3 } -- ********************************************************* -- Protocol DS1-CBR Port Definitions -- ********************************************************* -- this table include parameters in T1/E1 level which -- are relevant to cbr port only. atmSuPortDs1CbrCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmSuPortDs1CbrCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " This table include expansion configuration to the DS1 physical port." ::= { atmSuPortDs1 2 } atmSuPortDs1CbrCnfgEntry OBJECT-TYPE SYNTAX AtmSuPortDs1CbrCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "the entries at this table describes the configuration of the agent physical." INDEX { ifIndex } ::= { atmSuPortDs1CbrCnfgTable 1} AtmSuPortDs1CbrCnfgEntry ::= SEQUENCE { atmSuPortDs1CbrIdleCode Integer32, atmSuPortDs1CbrRxTimeSlots TimeSlots, atmSuPortDs1CbrTxTimeSlots TimeSlots, atmSuPortDs1CbrMaxNoOfConns Integer32, atmSuPortDs1CbrConfNoOfConns Integer32, atmSuPortDs1CbrSignallingSampleTime INTEGER } atmSuPortDs1CbrIdleCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "An Idle code which sent on unused time-slots at CBR port ." ::= { atmSuPortDs1CbrCnfgEntry 1 } atmSuPortDs1CbrRxTimeSlots OBJECT-TYPE SYNTAX TimeSlots MAX-ACCESS read-only STATUS current DESCRIPTION "This value indicates the time-slots used by the port for receiving. It uses 32 bits ( in 4 bytes octet string ) for E1 and low 24 bits for T1. each bit represents a time slot for receiving : time-slot 0 = bit 0 (LSB - most right bit in last byte), ... ... time-slot 31 = bit 31 (MSB - most left bit in first byte ). value '0' indicate unused time-slot and value '1' indicates used time-slot. note : time-slots '0' and '16' are used for signalling in E1 interface. " ::= { atmSuPortDs1CbrCnfgEntry 2 } atmSuPortDs1CbrTxTimeSlots OBJECT-TYPE SYNTAX TimeSlots MAX-ACCESS read-only STATUS current DESCRIPTION "This value indicates the time-slots used by the port for transmiting. It uses 32 bits for E1 and low 24 bits for T1. each bit represents a time slot for transmiting : time-slot 0 = bit 0 (LSB - most right bit in last byte), ... ... time-slot 31 = bit 31 (MSB - most left bit in first byte ). value '0' indicate unused time-slot and value '1' indicates used time-slot. note : time-slots '0' and '16' are used for signalling in E1 interface. " ::= { atmSuPortDs1CbrCnfgEntry 3 } atmSuPortDs1CbrMaxNoOfConns OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " this object indicates the maximum number of cross-connect connections allowed beetween the ATM port and the CBR Port identified by IfIndex. " ::= { atmSuPortDs1CbrCnfgEntry 4 } atmSuPortDs1CbrConfNoOfConns OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " this object indicates the configured number of cross-connect connections exist beetween the ATM port and the CBR Port identified by IfIndex. " ::= { atmSuPortDs1CbrCnfgEntry 5 } atmSuPortDs1CbrSignallingSampleTime OBJECT-TYPE SYNTAX INTEGER { msec100 (1), msec200 (2), msec500 (3), msec1000 (4), msec1500 (5), msec2000 (6) } MAX-ACCESS read-write STATUS current DESCRIPTION " determines how often the signalling of the DBCES connections are sampled and thier activity determined. " DEFVAL { msec500 } ::= { atmSuPortDs1CbrCnfgEntry 6 } -- ********************************************************* -- Protocol ATM Definitions -- ********************************************************* atmSuPortAtm OBJECT IDENTIFIER ::= { atmSuPort 3 } -- ATM expansions to RFC1695 atmSuPortAtmCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmSuPortAtmCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains global configuration to the ATM port." ::= { atmSuPortAtm 1 } atmSuPortAtmCnfgEntry OBJECT-TYPE SYNTAX AtmSuPortAtmCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object contains information about agent ATM configuration." INDEX { ifIndex } ::= { atmSuPortAtmCnfgTable 1 } AtmSuPortAtmCnfgEntry ::= SEQUENCE { atmSuPortAtmCnfgIdleCellCLP INTEGER, atmSuPortAtmCnfgScramble INTEGER, atmSuPortAtmSNMPVpi Integer32, atmSuPortAtmSNMPVci Integer32, atmSuPortAtmSNMPStatus INTEGER, atmSuPortAtmILMIStatus INTEGER, atmSuPortAtmSNMPIp IpAddress } atmSuPortAtmCnfgIdleCellCLP OBJECT-TYPE SYNTAX INTEGER { clp0 (1) , --> ATM Forum clp1 (2) --> ITU } MAX-ACCESS read-write STATUS current DESCRIPTION "Determines the clp bit value for transmition in empty time slots." ::= { atmSuPortAtmCnfgEntry 1 } atmSuPortAtmCnfgScramble OBJECT-TYPE SYNTAX INTEGER { enable (1) , disable (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Determined by the standards if the cell will be scrambled or not." ::= { atmSuPortAtmCnfgEntry 2 } atmSuPortAtmSNMPVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The Vcc Vpi for SNMP requests." ::= { atmSuPortAtmCnfgEntry 3 } atmSuPortAtmSNMPVci OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The Vcc Vci for SNMP requests." ::= { atmSuPortAtmCnfgEntry 4 } atmSuPortAtmSNMPStatus OBJECT-TYPE SYNTAX INTEGER { active (1) , notActive (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "value indicates if the SNMP Vcc is available for management." ::= { atmSuPortAtmCnfgEntry 5 } atmSuPortAtmILMIStatus OBJECT-TYPE SYNTAX INTEGER { active (1) , notActive (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Value indicates if agent should respond to ILMI requests from the Atm switch or forward it. note: when using Atm to Frame-Relay configuration this value should be active to support ILMI. when using Atm-AtmDxi configuration the ILMI requests should be moved forward to the DTE or may be answered by the DCE. " DEFVAL { active } ::= { atmSuPortAtmCnfgEntry 6 } atmSuPortAtmSNMPIp OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The interface IP address for SNMP requests." ::= { atmSuPortAtmCnfgEntry 7 } -- ************************************************************* -- RAD private ATM Interface statistics table. The table adds -- more columns to the RFC1695 atmInterfaceConfTable -- ************************************************************* atmSuPortAtmIfStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmSuPortAtmIfStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table contains additional statistics information about the ATM interface." ::= { atmSuPortAtm 2 } atmSuPortAtmIfStatsEntry OBJECT-TYPE SYNTAX AtmSuPortAtmIfStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ATM Interface statistics table." INDEX { ifIndex } ::= { atmSuPortAtmIfStatsTable 1 } AtmSuPortAtmIfStatsEntry ::= SEQUENCE { atmSuPortAtmRxClp0Cells Counter32, atmSuPortAtmRxClp1Cells Counter32, atmSuPortAtmRxEfciSetCells Counter32, atmSuPortAtmRxOamCells Counter32, atmSuPortAtmTxClp0Cells Counter32, atmSuPortAtmTxClp1Cells Counter32, atmSuPortAtmTxEfciSetCells Counter32, atmSuPortAtmTxOamCells Counter32 } atmSuPortAtmRxClp0Cells OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of cells received with correct HECs and CLP=0 and not misrouted" ::= { atmSuPortAtmIfStatsEntry 1 } atmSuPortAtmRxClp1Cells OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of cells received with correct HEC's and CLP=1 and not misrouted." ::= { atmSuPortAtmIfStatsEntry 2 } atmSuPortAtmRxEfciSetCells OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of cells received with EFCI bit set by the Agent" ::= { atmSuPortAtmIfStatsEntry 3 } atmSuPortAtmRxOamCells OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of OAM cells received with correct HECs." ::= { atmSuPortAtmIfStatsEntry 4 } atmSuPortAtmTxClp0Cells OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of cells transmitted with CLP=0." ::= { atmSuPortAtmIfStatsEntry 5 } atmSuPortAtmTxClp1Cells OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of cells transmitted with CLP=1." ::= { atmSuPortAtmIfStatsEntry 6 } atmSuPortAtmTxEfciSetCells OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of cells transmitted with EFCI bit set by the Agent" ::= { atmSuPortAtmIfStatsEntry 7 } atmSuPortAtmTxOamCells OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of transmitted OAM cells." ::= { atmSuPortAtmIfStatsEntry 8 } -- ************************************************************** -- RAD Vcl Statistics table. The table adds more columns to -- the RFC1695 atmVclTable -- ************************************************************** atmSuPortAtmVclStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmSuPortAtmVclStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table contains additional information about the ATM Vcl end points." ::= { atmSuPortAtm 3 } atmSuPortAtmVclStatsEntry OBJECT-TYPE SYNTAX AtmSuPortAtmVclStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ATM Vcl statistics table." INDEX {ifIndex, atmVclVpi, atmVclVci } ::= { atmSuPortAtmVclStatsTable 1 } AtmSuPortAtmVclStatsEntry ::= SEQUENCE { atmSuPortAtmVclStatsRxCells Counter32, atmSuPortAtmVclStatsRxClp0Cells Counter32, atmSuPortAtmVclStatsRxClp1Cells Counter32, atmSuPortAtmVclStatsRxDiscardsCells Counter32, atmSuPortAtmVclStatsTxCells Counter32, atmSuPortAtmVclStatsTxClp0Cells Counter32, atmSuPortAtmVclStatsTxClp1Cells Counter32, atmSuPortAtmVclStatsRxTotalAISCells Counter32, atmSuPortAtmVclStatsRxTotalCCCells Counter32, atmSuPortAtmVclStatsTotalSuccLoopbacks Counter32, atmSuPortAtmVclStatsTotalFailLoopbacks Counter32, atmSuPortAtmVclStatsRxTotalRDICells Counter32, atmSuPortAtmVclStatsTotalLOCSeconds Counter32, atmSuPortAtmVclStatsRxTotalLoopbackRequests Counter32, atmSuPortAtmVclStatsTxTotalAISCells Counter32, atmSuPortAtmVclStatsTxTotalCCCells Counter32, atmSuPortAtmVclStatsTxTotalRDICells Counter32, atmSuPortAtmVclStatsTxTotalLoopbackResponses Counter32, atmSuPortAtmVclStatsTxTotalLoopbackRequests Counter32, atmSuPortAtmVclStatsRxTotalLoopbackResponses Counter32 } atmSuPortAtmVclStatsRxCells OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of cells received with correct HEC's." ::= { atmSuPortAtmVclStatsEntry 1 } atmSuPortAtmVclStatsRxClp0Cells OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of cells received with correct HEC's and CLP=0." ::= { atmSuPortAtmVclStatsEntry 2 } atmSuPortAtmVclStatsRxClp1Cells OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of cells received with correct HEC's and CLP=1." ::= { atmSuPortAtmVclStatsEntry 3 } atmSuPortAtmVclStatsRxDiscardsCells OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of cells, in ingress direction, discarded due to policing violation." ::= { atmSuPortAtmVclStatsEntry 4 } atmSuPortAtmVclStatsTxCells OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of cells transmitted." ::= { atmSuPortAtmVclStatsEntry 5 } atmSuPortAtmVclStatsTxClp0Cells OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of cells transmitted with CLP=0." ::= { atmSuPortAtmVclStatsEntry 6 } atmSuPortAtmVclStatsTxClp1Cells OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of cells transmitted with CLP=1." ::= { atmSuPortAtmVclStatsEntry 7 } atmSuPortAtmVclStatsRxTotalAISCells OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of AIS cells received on the VC." ::= { atmSuPortAtmVclStatsEntry 8 } atmSuPortAtmVclStatsRxTotalCCCells OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of Continuity Check cells that were received on the VC." ::= { atmSuPortAtmVclStatsEntry 9 } atmSuPortAtmVclStatsTotalSuccLoopbacks OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of loopbacks that were requested by the ACE20 and for which there was a response (not supported)." ::= { atmSuPortAtmVclStatsEntry 10 } atmSuPortAtmVclStatsTotalFailLoopbacks OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of loopbacks that were requested by the ACE20 and for which there was no response (not supported)." ::= { atmSuPortAtmVclStatsEntry 11 } atmSuPortAtmVclStatsRxTotalRDICells OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of RDI cells received on a VC." ::= { atmSuPortAtmVclStatsEntry 12 } atmSuPortAtmVclStatsTotalLOCSeconds OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of seconds during which there was loss of continuity on the VC - no data and no continuity check cells were received on the VC whilst it was in 'sink' continuity check mode." ::= { atmSuPortAtmVclStatsEntry 13 } atmSuPortAtmVclStatsRxTotalLoopbackRequests OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of loopback requests received by the ACE20 on a VC." ::= { atmSuPortAtmVclStatsEntry 14 } atmSuPortAtmVclStatsTxTotalAISCells OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of AIS cells that were transmitted on a VC." ::= { atmSuPortAtmVclStatsEntry 15 } atmSuPortAtmVclStatsTxTotalCCCells OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of continuity check cells that were transmitted on a VC (when there is no data cells and the connection is in 'source' continuity check mode)." ::= { atmSuPortAtmVclStatsEntry 16 } atmSuPortAtmVclStatsTxTotalRDICells OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of RDI cells transmitted on a VC." ::= { atmSuPortAtmVclStatsEntry 17 } atmSuPortAtmVclStatsTxTotalLoopbackResponses OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of loopback responses that were transmitted as a result of loopback requests received." ::= { atmSuPortAtmVclStatsEntry 18 } atmSuPortAtmVclStatsTxTotalLoopbackRequests OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of loopback requests that were transmitted by the ACE20 on a VC." ::= { atmSuPortAtmVclStatsEntry 19 } atmSuPortAtmVclStatsRxTotalLoopbackResponses OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of loopback responses that were received as a result of loopback transmitted by the ACE20." ::= { atmSuPortAtmVclStatsEntry 20 } -- ************************************************************** -- RAD AAL1 Vcc Statistics table. This table includes all AAL1 -- connections which are not from CES/DBCES type. -- ************************************************************** -- Use atmCESAAL1StatsTable instead atmAAL1StatsTable --atmAAL1StatsTable OBJECT-TYPE -- SYNTAX SEQUENCE OF atmAAL1StatsEntry -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- "This table contains AAL1 VCC performance parameters." -- ::= { atmSuPortAtm 4 } -- --atmAAL1StatsEntry OBJECT-TYPE -- SYNTAX atmAAL1StatsEntry -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- "This list contains the AAL1 VCC performance parameters." -- INDEX { ifIndex } -- ::= { atmAAL1StatsTable 1 } -- --atmAAL1StatsEntry ::= SEQUENCE { -- atmVclVpi -- Integer32, -- atmVclVci -- Integer32, -- atmAAL1HdrErrors -- Counter32, -- atmAAL1SeqErrors -- Counter32 -- } -- --atmAAL1VclVpi OBJECT-TYPE -- SYNTAX Integer32 -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- "The SNMP Vpi of this entry." -- ::= { atmAAL1StatsEntry 1 } -- --atmAAL1VclVci OBJECT-TYPE -- SYNTAX Integer32 -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- "The SNMP Vci of this entry." -- ::= { atmAAL1StatsEntry 2 } -- --atmAAL1HdrErrors OBJECT-TYPE -- SYNTAX Counter32 -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- "The count of the number of AAL1 header errors detected, -- including those corrected. Header errors include correctable -- and uncorrectable CRC, plus bad parity." -- ::= { atmAAL1StatsEntry 3 } -- --atmAAL1SeqErrors OBJECT-TYPE -- SYNTAX Counter32 -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- "Number of AAL1 sequence violations which the AAL Convergence -- sublayer interprets as a misinserted cell, as defined by -- ITU-T I.363.1." -- ::= { atmAAL1StatsEntry 4 } -- ********************************************************** -- ********************************************************** -- Protocol FR Definitions -- ********************************************************** -- ********************************************************** atmSuPortFr OBJECT IDENTIFIER ::= { atmSuPort 4 } -- ********************************************************** -- the Frame Relay Logical Port Group -- ********************************************************** atmSuPortFrLportTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmSuPortFrLportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table Contains configuration parameters of the Frame-Relay port and has expansion to frLportTable in RFC1604 MIB." ::= { atmSuPortFr 1 } atmSuPortFrLportEntry OBJECT-TYPE SYNTAX AtmSuPortFrLportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Frame Relay Logical Port Information table." INDEX { ifIndex } ::= { atmSuPortFrLportTable 1 } AtmSuPortFrLportEntry ::= SEQUENCE { atmSuPortFrLportSNMPDlci Integer32, atmSuPortFrLportSNMPStatus INTEGER, atmSuPortFrLportVCSigProtocol INTEGER, atmSuPortFrLportVCSigProcedure INTEGER, atmSuPortFrLportCLLM INTEGER, atmSuPortFrLportSNMPIp IpAddress } atmSuPortFrLportSNMPDlci OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The SNMP Dlci of this entry." ::= { atmSuPortFrLportEntry 1 } atmSuPortFrLportSNMPStatus OBJECT-TYPE SYNTAX INTEGER { active (1) , notActive (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "value indicates if SNMP over FR is available for management." ::= { atmSuPortFrLportEntry 2 } atmSuPortFrLportVCSigProtocol OBJECT-TYPE SYNTAX INTEGER { none(1), ccittQ933A(2), ansiT1617D(3), lmi(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The value of this object identifies the Local In-Channel Signaling Protocol that is used for this frame relay UNI/NNI logical port." DEFVAL { none } ::= { atmSuPortFrLportEntry 3 } atmSuPortFrLportVCSigProcedure OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), u2nnet(2), u2nuser(3), bidirect(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The value of this object identifies the Local In-Channel Signaling Procedure that is used for this UNI/NNI logical port. The UNI/NNI logical port can be performing user-to-network network-side and user-to-network user-side procedures or bidirectional procedures. this parameter gets value 'notApplicable when the VCSigProtocol is none" ::= { atmSuPortFrLportEntry 4 } atmSuPortFrLportCLLM OBJECT-TYPE SYNTAX INTEGER { active (1), notActive(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " indicate if the configuration is supporting CLLM ( Consolidated Link Layer Management ) ." ::= { atmSuPortFrLportEntry 5 } atmSuPortFrLportSNMPIp OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The interface IP address of this entry." ::= { atmSuPortFrLportEntry 6 } -- *************************************************************** -- RAD Frame Relay Statistics table. The table add more -- columns to the RFC1604 frPVCEndptTable -- *************************************************************** atmSuPortFrPvcEndptTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmSuPortFrPvcEndptEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table contains additional information about the Frame Relay end point." ::= { atmSuPortFr 2 } atmSuPortFrPvcEndptEntry OBJECT-TYPE SYNTAX AtmSuPortFrPvcEndptEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry for FR end-point statistics ( expansion to RFC 1604 )." INDEX { ifIndex, frPVCEndptDLCIIndex } ::= { atmSuPortFrPvcEndptTable 1 } AtmSuPortFrPvcEndptEntry ::= SEQUENCE { atmSuPortFrPvcEndptTxFECNs Counter32, atmSuPortFrPvcEndptTxBECNs Counter32, atmSuPortFrPvcEndptTxDEs Counter32, atmSuPortFrPvcEndptRxFECNs Counter32, atmSuPortFrPvcEndptRxBECNs Counter32 } atmSuPortFrPvcEndptTxFECNs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "number of frames transmited with FECN ( Forward Explicit Congestion Notification )." ::= { atmSuPortFrPvcEndptEntry 1 } atmSuPortFrPvcEndptTxBECNs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "number of frames transmited with BECN ( Backward Explicit Congestion Notification )." ::= { atmSuPortFrPvcEndptEntry 2 } atmSuPortFrPvcEndptTxDEs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "number of frames transmited with the DE ( Discarded Eligible ) bit set." ::= { atmSuPortFrPvcEndptEntry 3 } atmSuPortFrPvcEndptRxFECNs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "number of frames received with FECN ( Forward Explicit Congestion Notification )." ::= { atmSuPortFrPvcEndptEntry 4 } atmSuPortFrPvcEndptRxBECNs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "number of frames received with BECN ( Backward Explicit Congestion Notification )." ::= { atmSuPortFrPvcEndptEntry 5 } -- *************************************************************** -- ATM-DXI Managment LMI Addresses -- *************************************************************** atmSuPortDxi OBJECT IDENTIFIER ::= { atmSuPort 5 } -- ATM-DXI definitions atmSuPortDxiConfTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmSuPortDxiConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains ATM-DXI managment address (DFA) ending at the local agent. only LMI managment supported for ATM-DXI." ::= { atmSuPortDxi 1 } atmSuPortDxiConfEntry OBJECT-TYPE SYNTAX AtmSuPortDxiConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object contains information about agent Dxi interface." INDEX { ifIndex } ::= { atmSuPortDxiConfTable 1 } AtmSuPortDxiConfEntry ::= SEQUENCE { atmSuPortDxiPortMode INTEGER, atmSuPortDxiSigProtocol INTEGER, atmSuPortDxiSigDfa Integer32 } atmSuPortDxiPortMode OBJECT-TYPE SYNTAX INTEGER { mode1a (1), mode1b (2), mode2 (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object identifies the dxi mode being used by the atm dxi port." ::= { atmSuPortDxiConfEntry 1 } atmSuPortDxiSigProtocol OBJECT-TYPE SYNTAX INTEGER { none (1) , lmi (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This value indicates if we using LMI signalling protocol or not using any signalling ." ::= { atmSuPortDxiConfEntry 2 } atmSuPortDxiSigDfa OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The Signalling Dfa address . the default LMI Dfa defined for LMI by the AtmForum is 0." DEFVAL { 0 } ::= { atmSuPortDxiConfEntry 3 } -- ************************************************************** atmSuPortCmdTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmSuPortCmdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "General commands to be done on agent's ports." ::= { atmSuPort 6 } atmSuPortCmdEntry OBJECT-TYPE SYNTAX AtmSuPortCmdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object contains entry information." INDEX { ifIndex } ::= { atmSuPortCmdTable 1 } AtmSuPortCmdEntry ::= SEQUENCE { atmSuResetPortStatsCmd INTEGER, atmSuResetConnsStatsCmd INTEGER } atmSuResetPortStatsCmd OBJECT-TYPE SYNTAX INTEGER { off(1), on (2) } MAX-ACCESS read-write STATUS current DESCRIPTION " reset statistics of port." ::= { atmSuPortCmdEntry 1 } atmSuResetConnsStatsCmd OBJECT-TYPE SYNTAX INTEGER { off(1), on (2) } MAX-ACCESS read-write STATUS current DESCRIPTION " reset statistics of all cross connections attached to this port. set-request is allowed only on the DATA Ports . for get-request value is always 'off' " ::= { atmSuPortCmdEntry 2 } -- ********************************************************** -- ********************************************************** -- Protocol Ethernet Definitions -- ********************************************************** -- ********************************************************** atmSuPortEther OBJECT IDENTIFIER ::= { atmSuPort 7 } -- ********************************************************** -- the Ethernet Port Group -- ********************************************************** atmSuPortEtherTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmSuPortEtherEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table Contains configuration parameters of the Ethernet port." ::= { atmSuPortEther 1 } atmSuPortEtherEntry OBJECT-TYPE SYNTAX AtmSuPortEtherEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Ethernet Port Information table." INDEX { ifIndex } ::= { atmSuPortEtherTable 1 } AtmSuPortEtherEntry ::= SEQUENCE { atmSuPortEtherIP IpAddress, atmSuPortEtherMask IpAddress, atmSuPortEtherDefaultGateWayIp IpAddress, atmSuPortEtherDefaultCrossConnectId Integer32, atmSuPortEtherDefaultGatewayStatus INTEGER, atmSuPortEtherSNMPStatus INTEGER, atmSuPortEtherFragmentation INTEGER, atmSuPortEtherRIPMode INTEGER, atmSuPortEtherBridgingMode INTEGER, atmSuPortEtherARPTimeout Integer32, atmSuPortEtherAgingTime Integer32, atmSuPortEtherPppOEEnable INTEGER } atmSuPortEtherIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The interface IP address for SNMP requests." ::= { atmSuPortEtherEntry 1 } atmSuPortEtherMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The interface IP address mask for SNMP requests." ::= { atmSuPortEtherEntry 2 } atmSuPortEtherDefaultGateWayIp OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The Ethernet bridge default gateway IP address." ::= { atmSuPortEtherEntry 3 } atmSuPortEtherDefaultCrossConnectId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { atmSuPortEtherEntry 4 } atmSuPortEtherDefaultGatewayStatus OBJECT-TYPE SYNTAX INTEGER { active (1) , notActive (2) , notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { atmSuPortEtherEntry 5 } atmSuPortEtherSNMPStatus OBJECT-TYPE SYNTAX INTEGER { active (1) , notActive (2) , notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "value indicates if the SNMP of Ethernet bridge interface is available for management." ::= { atmSuPortEtherEntry 6 } atmSuPortEtherFragmentation OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Fragmentation. When application is not router value must be 'notApplicable'." ::= { atmSuPortEtherEntry 7 } atmSuPortEtherRIPMode OBJECT-TYPE SYNTAX INTEGER { rip1 (1), rip2 (2), rip1And2 (3), none (4), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "RIP Mode. When application is not router value must be 'notApplicable'." ::= { atmSuPortEtherEntry 8 } atmSuPortEtherBridgingMode OBJECT-TYPE SYNTAX INTEGER { accessOnly (1), accessAndSwitching (2), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Bridging mode can be one of the following: ATM <> Ethernet - Bridging is between the Ethernet port and the ATM port (there is no bridging between VCs). ATM <> Ethernet + ATM - Bridging is done both between the Ethernet port and the ATM port and also between VCs. When application is router value must be 'notApplicable'." ::= { atmSuPortEtherEntry 9 } atmSuPortEtherARPTimeout OBJECT-TYPE SYNTAX Integer32 (0..10) MAX-ACCESS read-write STATUS current DESCRIPTION "ARP Timeout. When application is not router value must be 0." DEFVAL { 5 } ::= { atmSuPortEtherEntry 10 } atmSuPortEtherAgingTime OBJECT-TYPE SYNTAX Integer32 (10..1000000) MAX-ACCESS read-write STATUS current DESCRIPTION "The timeout period in seconds for aging out stored information. " ::= { atmSuPortEtherEntry 11 } atmSuPortEtherPppOEEnable OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), off (2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable or Disable transparent PPP over ethernet bridge. When PPP over Ethernet is enabled, non PPP traffic is blocked by the bridge." ::= { atmSuPortEtherEntry 12 } -- ************************************************************* -- ************************************************************* -- Cross-Connect connections definitions -- ************************************************************* -- ************************************************************* atmSuCrossConnect OBJECT IDENTIFIER ::= { atmSu 3 } -- cross connect definitions -- ************************************************************* -- RAD ATM to Frame Relay endpoints Connections group -- ************************************************************* atmSuCrossConnectAtmFr OBJECT IDENTIFIER ::= { atmSuCrossConnect 1 } --AtmSuCrossConnectAtmFrDescrIndex ::= TEXTUAL-CONVENTION -- STATUS current -- DESCRIPTION -- "The value of this object identifies the row -- in the atmSuCrossConnectAtmFrDescrTable." -- SYNTAX Integer32 atmSuCrossConnectAtmFrDescriptor OBJECT IDENTIFIER ::= { atmSuCrossConnectAtmFr 1 } -- ************************************************************* -- RAD ATM to Frame Relay connection types group -- The group contains ATM to Frame Relay connection modes, -- defining the connection parameters. -- ************************************************************* atmFrCrossConnectNetwork OBJECT IDENTIFIER ::= { atmSuCrossConnectAtmFrDescriptor 1 } -- atmFrCrossConnectNetwork OBJECT-IDENTITY -- STATUS current -- DESCRIPTION -- "This connection descriptor is network connection mode. -- The use of the parameter vector for this type: -- Clp2De : ATM CLP to Frame Relay DE mapping mode. -- The following values are allowed: -- convSscs- The DE bit of the FR-SSCS PDU is copied Q.922 -- DE field. -- conv- If one or more ATM cells belonging to a frame has -- its CLP bit set, or the DE field -- of the FR-SSCS PDU is set, then the DE bit -- of the Q.922 core frame is set. -- De2Clp: Frame Relay DE to ATM CLP mapping mode. -- ( DE bit is always copied unchanged to the FR-SSCS PDU header ). -- The following values are allowed: -- conv - The Q.922 DE bit is mapped to every CLP bit. -- always0- CLP bit is always 0. -- always1- CLP bit is always 1. -- Fecn2Efci : Not used -- MappingMode: Not used -- " -- ::= { atmSuCrossConnectAtmFrDescriptor 1} -- atmFrCrossConnectService OBJECT-IDENTITY -- STATUS current -- DESCRIPTION -- "This connection descriptor is service connection mode. -- The use of the parameter vector for this type: -- Clp2De : ATM CLP to Frame Relay DE mapping mode. -- The following values are allowed: -- conv - If one or more ATM cells belonging to a frame has -- its CLP bit set, then the DE bit -- of the Q.922 core frame is set. -- always0- The DE bit is always 0. -- always1- The DE bit is always 1. -- De2Clp : Frame Relay DE to ATM CLP mapping mode. -- The following values are allowed: -- conv - The DE bit is mapped to every CLP bit. -- always0- CLP bit is always 0 -- always1- CLP bit is always 1 -- Fecn2Efci: Frame Relay FECN to ATM EFCI mapping mode. -- The following values are allowed: -- conv - The FECN bit is mapped to every EFCI bit. -- always0- EFCI bit is always 0. -- MappingMode: Upper Layer mapping mode. -- The following values are allowed: -- transparent - trasparent mode -- translation - translation mode -- note : value 0 for parameter means that it is not supported . -- " -- ::= { atmSuCrossConnectAtmFrDescriptor 2 } atmFrCrossConnectService OBJECT IDENTIFIER ::= { atmSuCrossConnectAtmFrDescriptor 2 } -- ************************************************************* -- RAD ATM to Frame Relay connection descriptor table. -- ************************************************************* atmFrDescrTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmFrDescrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains information on ATM to FR Connection descriptor types, and their associated parameters." ::= { atmSuCrossConnectAtmFr 2 } atmFrDescrEntry OBJECT-TYPE SYNTAX AtmFrDescrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This list contains ATM to FR Connection descriptor type, and its associated parameters." INDEX { atmFrDescrIndex } ::= { atmFrDescrTable 1} AtmFrDescrEntry ::= SEQUENCE { atmFrDescrIndex Integer32, -- was AtmSuCrossConnectAtmFrDescrIndex, atmFrDescrType OBJECT IDENTIFIER, atmFrDescrClp2De INTEGER, atmFrDescrDe2Clp INTEGER, atmFrDescrFecn2Efci INTEGER, atmFrDescrMappingMode INTEGER, atmFrDescrRowStatus RowStatus } atmFrDescrIndex OBJECT-TYPE SYNTAX Integer32 -- was AtmSuCrossConnectAtmFrDescrIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This object is used to identify the row index of the ATM to FR connection descriptor table." ::= { atmFrDescrEntry 1 } atmFrDescrType OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-create STATUS current DESCRIPTION "The value of this object identifies the type of the ATM to FR Connection descriptor. The type may indicate Network connection descriptor or a Service connection descriptor with one or more parameters. These parameters are specified as a parameter vector, in the corresponding instances of the objects: atmFrDescrClp2De atmFrDescrDe2Clp atmFrDescrFecn2Efci atmFrDescrMappingMode." ::= { atmFrDescrEntry 2 } atmFrDescrClp2De OBJECT-TYPE SYNTAX INTEGER { convSscs (1), conv (2), always0 (3), always1 (4) } MAX-ACCESS read-create STATUS current DESCRIPTION "The first parameter of the ATM to FR Connection descriptor used according to the value of atmFrDescrType." DEFVAL { conv } ::= { atmFrDescrEntry 3 } atmFrDescrDe2Clp OBJECT-TYPE SYNTAX INTEGER { conv (1), always0 (2), always1 (3) } MAX-ACCESS read-create STATUS current DESCRIPTION "The second parameter of the ATM to FR Connection descriptor used according to the value of atmFrDescrType." DEFVAL { conv } ::= { atmFrDescrEntry 4 } atmFrDescrFecn2Efci OBJECT-TYPE SYNTAX INTEGER { conv (1), always0 (2) } MAX-ACCESS read-create STATUS current DESCRIPTION "The third parameter of the ATM to FR Connection descriptor used according to the value of atmFrDescrType." DEFVAL { conv } ::= { atmFrDescrEntry 5 } atmFrDescrMappingMode OBJECT-TYPE SYNTAX INTEGER { transparent (1), translation (2) } MAX-ACCESS read-create STATUS current DESCRIPTION "The fourth parameter of the ATM to FR Connection descriptor used according to the value of atmFrDescrType." DEFVAL { translation } ::= { atmFrDescrEntry 6 } atmFrDescrRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object is used to create, modify or delete a row in this table." DEFVAL { active } ::= { atmFrDescrEntry 7 } -- ************************************************************* -- RAD ATM to Frame Relay connection table group -- ************************************************************* -- RAD ATM to Frame Relay connection table. atmSuCrossConnectAtmFrIndexNext OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains an appropriate value to be used for atmFrCnfgCrossConnectIndex when creating entries in the atmFrCnfgTable. The value 0 indicates that no unassigned entries are available. To obtain the atmFrCnfgCrossConnectIndex value for a new entry, the manager issues a management protocol retrieval operation to obtain the mandatory value of this object. After each retrieval, the agent should modify the value to the next unassigned index." ::= { atmSuCrossConnectAtmFr 3 } atmFrCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmFrCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table defines virtual connections between ATM and Frame Relay endpoints." ::= { atmSuCrossConnectAtmFr 4 } atmFrCnfgEntry OBJECT-TYPE SYNTAX AtmFrCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry defines virtual connection between ATM and Frame Relay endpoint." INDEX { atmFrCnfgCrossConnectIndex, atmFrCnfgAtmIfIndex, atmFrCnfgAtmVpi, atmFrCnfgAtmVci, atmFrCnfgFrIfIndex, atmFrCnfgDlci } ::= { atmFrCnfgTable 1 } AtmFrCnfgEntry ::= SEQUENCE { atmFrCnfgCrossConnectIndex Integer32, atmFrCnfgAtmIfIndex Integer32, atmFrCnfgAtmVpi Integer32, atmFrCnfgAtmVci Integer32, atmFrCnfgFrIfIndex Integer32, atmFrCnfgDlci Integer32, atmFrCnfgAdminStatus INTEGER, atmFrCnfgOperStatus INTEGER, atmFrCnfgLastChange TimeStamp, atmFrCnfgMappingDescrIndex Integer32, -- was AtmSuCrossConnectAtmFrDescrIndex, atmFrCnfgSscsDlci Integer32, atmFrCnfgTrafficDescrIndex AtmTrafficDescrParamIndex, atmFrCnfgPriority INTEGER, atmFrCnfgRowStatus RowStatus, atmFrCnfgAllocatedBuffers Integer32 } atmFrCnfgCrossConnectIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value to identify this cross-connect." ::= { atmFrCnfgEntry 1 } atmFrCnfgAtmIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The ifIndex associated to the ATM interface." ::= { atmFrCnfgEntry 2 } atmFrCnfgAtmVpi OBJECT-TYPE SYNTAX Integer32 (1..4095) MAX-ACCESS read-only STATUS current DESCRIPTION "The Vpi number of the ATM end point." ::= { atmFrCnfgEntry 3 } atmFrCnfgAtmVci OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The Vci number of the ATM end point." ::= { atmFrCnfgEntry 4 } atmFrCnfgFrIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The ifIndex associated to the Frame Relay interface." ::= { atmFrCnfgEntry 5 } atmFrCnfgDlci OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The DLCI number of the FR end point." ::= { atmFrCnfgEntry 6 } atmFrCnfgAdminStatus OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the connection status requested by the user." ::= { atmFrCnfgEntry 7 } atmFrCnfgOperStatus OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Operational status of the connection." ::= { atmFrCnfgEntry 8 } atmFrCnfgLastChange OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime at the time the ATM to FR connection entered its mandatory operational state. If the mandatory state was entered prior to the last re-initialization of the local network management subsystem, then this object contains a zero value." ::= { atmFrCnfgEntry 9 } atmFrCnfgMappingDescrIndex OBJECT-TYPE SYNTAX Integer32 -- was AtmSuCrossConnectAtmFrDescrIndex MAX-ACCESS read-create STATUS current DESCRIPTION "The value of this object identifies the row in the atmFrDescrTable." ::= { atmFrCnfgEntry 10 } atmFrCnfgSscsDlci OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The DLCI number given to the SSCS Sub-layer for network interworking only ( the default value is 'atmFrCnfgDlci' ). for Service Interworking do not implement this variable." ::= { atmFrCnfgEntry 11 } -- atmFrCnfgBitRate OBJECT-TYPE -- SYNTAX INTEGER -- { -- ubr (1) , -- vbr (2) , -- abr (3) -- } -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- "The traffic bit rate mode for this connection. -- note :setting this value is allowed only to point2point connections. -- for many2one connections is being set by the -- atmFrCrossConnectMany2OneRootsTable and this field is equal -- to this setting." -- ::= { atmFrCnfgEntry 12 } atmFrCnfgTrafficDescrIndex OBJECT-TYPE SYNTAX AtmTrafficDescrParamIndex MAX-ACCESS read-create STATUS current DESCRIPTION "The value of this object identifies the row in the atmTrafficDescrParamTable which applies to the transmit direction of the VCL. note :setting this value is allowed only to point2point connections. for many2one connections is being set by the atmFrCrossConnectMany2OneRootsTable and this field is equal to this setting." ::= { atmFrCnfgEntry 12 } atmFrCnfgPriority OBJECT-TYPE SYNTAX INTEGER { highPriority (1), mediumPriority (2), lowPriority (3) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object define the priority of connection. The first parameter affects the transmition of cells in Conjested network is the bitRate( Cbr has the highest priority and then Vbr,Ubr ) In connections with the same bitRate this object will define the priority." ::= { atmFrCnfgEntry 13 } atmFrCnfgRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object is used to create a new row or modify or delete an existing row in this table." ::= { atmFrCnfgEntry 14 } atmFrCnfgAllocatedBuffers OBJECT-TYPE SYNTAX Integer32 (10..217) MAX-ACCESS read-create STATUS current DESCRIPTION "This object enables user to limit the amount of buffers used by the connection. The limit set by this object will give the effect of a virtual buffer pool per connection. The user can allocate between 10 to 217 buffers to every connection. By default the limit is 50 buffers. Sum of limits allocated to all connections must not exceed the total amount of available buffers. Whenever a connection exceeds it's buffer limit due to congestion or burst - traffic is discarded" DEFVAL { 50 } ::= { atmFrCnfgEntry 15 } atmFrMaxMany2OneConnsPerVcc OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The Maximum Number of many2one cross-connect connections allowed per Vcc ." ::= { atmSuCrossConnectAtmFr 5 } -- ************************************************************* -- RAD ATM to ATM-DXI endpoints Connections group -- ************************************************************* atmSuCrossConnectAtmDxi OBJECT IDENTIFIER ::= { atmSuCrossConnect 2 } atmSuCrossConnectAtmDxiIndexNext OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains an appropriate value to be used for atmDxiCnfgCrossConnectIndex when creating entries in the atmDxiCnfgTable. The value 0 indicates that no unassigned entries are available. To obtain the atmDxiCnfgCrossConnectIndex value for a new entry, the manager issues a management protocol retrieval operation to obtain the mandatory value of this object. After each retrieval, the agent should modify the value to the next unassigned index." ::= { atmSuCrossConnectAtmDxi 1 } atmDxiCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmDxiCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table defines virtual connections between ATM and ATM-DXI endpoints." ::= { atmSuCrossConnectAtmDxi 2 } atmDxiCnfgEntry OBJECT-TYPE SYNTAX AtmDxiCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry defines virtual connection between ATM and ATM-DXI endpoint." INDEX { atmDxiCnfgCrossConnectIndex, atmDxiCnfgAtmIfIndex, atmDxiCnfgAtmVpi, atmDxiCnfgAtmVci, atmDxiCnfgDxiIfIndex, atmDxiCnfgDfa } ::= { atmDxiCnfgTable 1 } AtmDxiCnfgEntry ::= SEQUENCE { atmDxiCnfgCrossConnectIndex Integer32, atmDxiCnfgAtmIfIndex Integer32, atmDxiCnfgAtmVpi Integer32, atmDxiCnfgAtmVci Integer32, atmDxiCnfgDxiIfIndex Integer32, atmDxiCnfgDfa Integer32, atmDxiCnfgAdminStatus INTEGER, atmDxiCnfgOperStatus INTEGER, atmDxiCnfgLastChange TimeStamp, atmDxiCnfgTrafficDescrIndex AtmTrafficDescrParamIndex, atmDxiCnfgPriority INTEGER, atmDxiCnfgRowStatus RowStatus } atmDxiCnfgCrossConnectIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value to identify this cross-connect." ::= { atmDxiCnfgEntry 1 } atmDxiCnfgAtmIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The ifIndex associated to the ATM interface." ::= { atmDxiCnfgEntry 2 } atmDxiCnfgAtmVpi OBJECT-TYPE SYNTAX Integer32 (1..4095) MAX-ACCESS read-only STATUS current DESCRIPTION "The Vpi number of the ATM end point." ::= { atmDxiCnfgEntry 3 } atmDxiCnfgAtmVci OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The Vci number of the ATM end point." ::= { atmDxiCnfgEntry 4 } atmDxiCnfgDxiIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The ifIndex associated to the atm-dxi interface." ::= { atmDxiCnfgEntry 5 } atmDxiCnfgDfa OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The DFA number of the DXI end point." ::= { atmDxiCnfgEntry 6 } atmDxiCnfgAdminStatus OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "The requested state of the ATM to DXI connection." ::= { atmDxiCnfgEntry 7 } atmDxiCnfgOperStatus OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The real operational status of the ATM to DXI connection." ::= { atmDxiCnfgEntry 8 } atmDxiCnfgLastChange OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime at the time the ATM to DXI connection entered its mandatory operational state. If the mandatory state was entered prior to the last re-initialization of the local network management subsystem, then this object contains a zero value. Same value define both direction ( Atm2Dxi and Dxi2Atm )." ::= { atmDxiCnfgEntry 9 } -- atmDxiCnfgBitRate OBJECT-TYPE -- SYNTAX INTEGER -- { -- ubr (1) , -- vbr (2) , -- abr (3) -- } -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- "The traffic bit rate mode for this connection." -- ::= { atmDxiCnfgEntry 10 } atmDxiCnfgTrafficDescrIndex OBJECT-TYPE SYNTAX AtmTrafficDescrParamIndex MAX-ACCESS read-create STATUS current DESCRIPTION "The value of this object identifies the row in the atmTrafficDescrParamTable which applies to the transmit direction of the VCL." ::= { atmDxiCnfgEntry 10 } atmDxiCnfgPriority OBJECT-TYPE SYNTAX INTEGER { highPriority (1), mediumPriority (2), lowPriority (3) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object define the priority of connection. The first parameter affects the transmition of cells in Conjested network is the bitRate( Cbr has the highest priority and then Vbr,Ubr ) In connections with the same bitRate this object will define the priority." ::= { atmDxiCnfgEntry 11 } atmDxiCnfgRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object is used to create a new row or modify or delete an existing row in this table." ::= { atmDxiCnfgEntry 12 } -- ************************************************************* -- RAD ATM to CBR Connections group (excluded CES/DBCES -- connections which are handled in the CES table) -- ************************************************************* atmSuAtmCbr OBJECT IDENTIFIER ::= { atmSuCrossConnect 3 } atmCbrCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmCbrCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table defines AAL1 virtual connections (not CES) between ATM port and DS1-CBR port." ::= { atmSuAtmCbr 1 } atmCbrCnfgEntry OBJECT-TYPE SYNTAX AtmCbrCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry defines virtual connection between ATM port and DS1-CBR port." INDEX { atmCbrCnfgAtmIfIndex, atmCbrCnfgAtmVpi, atmCbrCnfgAtmVci, atmCbrCnfgCbrIfIndex } ::= { atmCbrCnfgTable 1 } AtmCbrCnfgEntry ::= SEQUENCE { atmCbrCnfgAtmIfIndex Integer32, atmCbrCnfgAtmVpi Integer32, atmCbrCnfgAtmVci Integer32, atmCbrCnfgCbrIfIndex Integer32, atmCbrCnfgAdminStatus INTEGER, atmCbrCnfgOperStatus INTEGER, atmCbrCnfgLastChange TimeStamp, atmCbrCnfgAAL1Signalling INTEGER, atmCbrCnfgRxTimeSlots TimeSlots, atmCbrCnfgRxBytesPerCell Integer32, atmCbrCnfgTxTimeSlots TimeSlots, atmCbrCnfgTxBytesPerCell Integer32, atmCbrCnfgParity INTEGER, atmCbrCnfgRowStatus RowStatus } atmCbrCnfgAtmIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The ifIndex associated to the ATM interface." ::= { atmCbrCnfgEntry 1 } atmCbrCnfgAtmVpi OBJECT-TYPE SYNTAX Integer32 (1..4095) MAX-ACCESS read-only STATUS current DESCRIPTION "The Vpi number of the ATM end point." ::= { atmCbrCnfgEntry 2 } atmCbrCnfgAtmVci OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The Vci number of the ATM end point." ::= { atmCbrCnfgEntry 3 } atmCbrCnfgCbrIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The ifIndex associated to the logical interface of DS0s bundle or to ifIndex of one of the data ports." ::= { atmCbrCnfgEntry 4 } atmCbrCnfgAdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-create STATUS current DESCRIPTION "The requested status of the connection." ::= { atmCbrCnfgEntry 5 } atmCbrCnfgOperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The real operational status of the connection." ::= { atmCbrCnfgEntry 6 } atmCbrCnfgLastChange OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime at the time the ATM to CBR connection entered its mandatory operational state. If the mandatory state was entered prior to the last re-initialization of the local network management subsystem, then this object contains a zero value. Same value define both direction ( Atm2Cbr and Cbr2Atm )." ::= { atmCbrCnfgEntry 7 } atmCbrCnfgAAL1Signalling OBJECT-TYPE SYNTAX INTEGER { off (1), on (2) } MAX-ACCESS read-create STATUS current DESCRIPTION "Not in use. Must be always 'off'." ::= { atmCbrCnfgEntry 8 } atmCbrCnfgRxTimeSlots OBJECT-TYPE SYNTAX TimeSlots MAX-ACCESS read-create STATUS current DESCRIPTION "This value indicates the time-slots used by this connection for receiving. It uses 32 bits for E1 and low 24 bits for T1. each bit represents a time slot for receiving : time-slot 0 = bit 0 (LSB - most right bit in last byte), ... ... time-slot 31 = bit 31 (MSB - most left bit in first byte ). value '0' indicate unused time-slot and value '1' indicates used time-slot. On set-request the user indicates the time-slot he needs for requested ATM-Vcc by putting '1' to the right bits. note : time-slots '0' and '16' are used for signalling in E1 interface. Currently not in use. Must be '0'." ::= { atmCbrCnfgEntry 9 } atmCbrCnfgRxBytesPerCell OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "number of bytes to be receive in order per cell to low the delay. " DEFVAL { 47 } ::= { atmCbrCnfgEntry 10 } atmCbrCnfgTxTimeSlots OBJECT-TYPE SYNTAX TimeSlots MAX-ACCESS read-create STATUS current DESCRIPTION "This value indicates the time-slots used by this connection for receiving. It uses 32 bits for E1 and low 24 bits for T1. each bit represents a time slot for receiving : time-slot 0 = bit 0 (LSB - most right bit in last byte), ... ... time-slot 31 = bit 31 (MSB - most left bit in first byte ). value '0' indicate unused time-slot and value '1' indicates used time-slot. On set-request the user indicates the time-slot he needs for requested ATM-Vcc by putting '1' to the right bits. note : time-slots '0' and '16' are used for signalling in E1 interface. Currently not in use. Must be '0'." ::= { atmCbrCnfgEntry 11 } atmCbrCnfgTxBytesPerCell OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "number of bytes to be transmit in order per cell to low the delay. " DEFVAL { 47 } ::= { atmCbrCnfgEntry 12 } atmCbrCnfgParity OBJECT-TYPE SYNTAX INTEGER { off (1), on (2), notApplicable (3) } MAX-ACCESS read-create STATUS current DESCRIPTION " Indicate if we'll add even parity to the pointer of the structure of CES. Currently not in use. Must be 'notApplicable'." ::= { atmCbrCnfgEntry 13 } atmCbrCnfgRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object is used to create a new row or modify or delete an existing row in this table." ::= { atmCbrCnfgEntry 14 } -- ************************************************************* -- RAD ATM to CES ( Circuit-Emulation or DBCES data over DS1 ) -- Connections group -- ************************************************************* atmCESConfExtnsTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmCESConfExtnsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table defines virtual connections between ATM port and DS1-CBR port." ::= { atmSuAtmCbr 2 } atmCESConfExtnsEntry OBJECT-TYPE SYNTAX AtmCESConfExtnsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry defines virtual connection between ATM port and DS1-CBR port." -- AUGMENTS { atmfCESConfEntry } INDEX { atmfCESCbrIndex } ::= { atmCESConfExtnsTable 1 } AtmCESConfExtnsEntry ::= SEQUENCE { atmCESLastChange TimeStamp, atmCESRxBytesPerCell Integer32, atmCESTxBytesPerCell Integer32, atmCESAal1Type INTEGER, atmCESParity INTEGER, atmCESSigType INTEGER, atmCESSigABBits OCTET STRING } atmCESLastChange OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime at the time the ATM to CBR connection entered its mandatory operational state. If the mandatory state was entered prior to the last re-initialization of the local network management subsystem, then this object contains a zero value." ::= { atmCESConfExtnsEntry 1 } atmCESRxBytesPerCell OBJECT-TYPE SYNTAX Integer32 (1..47) MAX-ACCESS read-write STATUS current DESCRIPTION "Number of bytes to be received per cell, in order to decrease the delay. " DEFVAL { 47 } ::= { atmCESConfExtnsEntry 2 } atmCESTxBytesPerCell OBJECT-TYPE SYNTAX Integer32 (1..47) MAX-ACCESS read-write STATUS current DESCRIPTION "Number of bytes to be transmitted per cell, in order to decrease the delay. " DEFVAL { 47 } ::= { atmCESConfExtnsEntry 3 } atmCESAal1Type OBJECT-TYPE SYNTAX INTEGER { ces(1), dbces(2), transparent(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Type of CBR connection: CES , DBCES or transparent ." ::= { atmCESConfExtnsEntry 4 } atmCESParity OBJECT-TYPE SYNTAX INTEGER { off (1), on (2) } MAX-ACCESS read-write STATUS current DESCRIPTION " Indicate if we'll add even parity to the pointer of the structure of CES." ::= { atmCESConfExtnsEntry 5 } atmCESSigType OBJECT-TYPE SYNTAX INTEGER { eAndmOrPlar (1), fxoLoopStart (2), fxsLoopStart (3), fxoGroundStart (4), fxsGroundStart (5), r2 (6), other (7) } MAX-ACCESS read-write STATUS current DESCRIPTION "type of signalling for a DBCES connection. Must be 'other' for CES connection." ::= { atmCESConfExtnsEntry 6 } atmCESSigABBits OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute is applicable only when value of atmCESSigType is other. Represents the AB bits for Rx/Tx and their masks in this way: bits 7..6: Tx AB bits value, bits 5..4: Tx AB bits mask, bits 3..2: Rx AB bits value, bits 1..0: Rx AB bits mask. All bits must be 0 for CES connection." ::= { atmCESConfExtnsEntry 7 } -- ************************************************************* -- RAD ATM to ETHERNET endpoints Connections group -- ************************************************************* atmSuCrossConnectAtmEther OBJECT IDENTIFIER ::= { atmSuCrossConnect 4 } atmSuCrossConnectAtmEtherIndexNext OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains an appropriate value to be used for atmEtherCnfgCrossConnectIndex when creating entries in the atmEtherCnfgTable. The value 0 indicates that no unassigned entries are available. To obtain the atmEtherCnfgCrossConnectIndex value for a new entry, the manager issues a management protocol retrieval operation to obtain the current value of this object. After each retrieval, the agent should modify the value to the next unassigned index." ::= { atmSuCrossConnectAtmEther 1 } atmEtherCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmEtherCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table defines virtual connections between ATM and ATM-BridgedEthernet endpoints." ::= { atmSuCrossConnectAtmEther 2 } atmEtherCnfgEntry OBJECT-TYPE SYNTAX AtmEtherCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry defines virtual connection between ATM and ATM-Ethernet endpoint." INDEX { atmEtherCnfgCrossConnectIndex, atmEtherCnfgAtmIfIndex, atmEtherCnfgAtmVpi, atmEtherCnfgAtmVci, atmEtherCnfgEtherIfIndex } ::= { atmEtherCnfgTable 1 } AtmEtherCnfgEntry ::= SEQUENCE { atmEtherCnfgCrossConnectIndex Integer32, atmEtherCnfgAtmIfIndex Integer32, atmEtherCnfgAtmVpi Integer32, atmEtherCnfgAtmVci Integer32, atmEtherCnfgEtherIfIndex Integer32, atmEtherCnfgMacAddr MacAddress, atmEtherCnfgAdminStatus INTEGER, atmEtherCnfgOperStatus INTEGER, atmEtherCnfgLastChange TimeStamp, atmEtherCnfgTrafficDescrIndex AtmTrafficDescrParamIndex, atmEtherCnfgEncapsulationMode INTEGER, atmEtherCnfgPriority INTEGER, atmEtherCnfgRowStatus RowStatus, atmEtherCnfgRouterIP IpAddress, atmEtherCnfgRouterMask IpAddress, atmEtherCnfgRouterFragmentation INTEGER, atmEtherCnfgRouterRIPMode INTEGER, atmEtherCnfgRouterMTU Integer32, atmEtherCnfgPPPEncapsulation INTEGER, atmEtherCnfgAllocatedBuffers Integer32 } atmEtherCnfgCrossConnectIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value to identify this cross-connect." ::= { atmEtherCnfgEntry 1 } atmEtherCnfgAtmIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The ifIndex associated to the ATM interface." ::= { atmEtherCnfgEntry 2 } atmEtherCnfgAtmVpi OBJECT-TYPE SYNTAX Integer32 (1..4095) MAX-ACCESS read-only STATUS current DESCRIPTION "The Vpi number of the ATM end point." ::= { atmEtherCnfgEntry 3 } atmEtherCnfgAtmVci OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The Vci number of the ATM end point." ::= { atmEtherCnfgEntry 4 } atmEtherCnfgEtherIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The ifIndex associated to the atm-Ethernet interface." ::= { atmEtherCnfgEntry 5 } atmEtherCnfgMacAddr OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The DFA number of the Ethernet end point." ::= { atmEtherCnfgEntry 6 } atmEtherCnfgAdminStatus OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "The requested state of the ATM to Ethernet connection." ::= { atmEtherCnfgEntry 7 } atmEtherCnfgOperStatus OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The real operational status of the ATM to Ethernet connection." ::= { atmEtherCnfgEntry 8 } atmEtherCnfgLastChange OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime at the time the ATM to Ethernet connection entered its current operational state. If the current state was entered prior to the last re-initialization of the local network management subsystem, then this object contains a zero value. Same value define both direction ( Atm2Ether and Ether2Atm )." ::= { atmEtherCnfgEntry 9 } atmEtherCnfgTrafficDescrIndex OBJECT-TYPE SYNTAX AtmTrafficDescrParamIndex MAX-ACCESS read-create STATUS current DESCRIPTION "The value of this object identifies the row in the atmTrafficDescrParamTable which applies to the transmit direction of the VCL." ::= { atmEtherCnfgEntry 10 } atmEtherCnfgEncapsulationMode OBJECT-TYPE SYNTAX INTEGER { atmBridgedEther (1), atmBridgedEtherCRC (2) } MAX-ACCESS read-create STATUS deprecated DESCRIPTION "This object define the encapsulation type requested for the connection. it indicates if we transfer the Ethernet frame to the atm side without the Crc32- AtmBridgedEther, or with it - AtmBridgedEther_CRC. " DEFVAL { atmBridgedEther } ::= { atmEtherCnfgEntry 11 } atmEtherCnfgPriority OBJECT-TYPE SYNTAX INTEGER { highPriority (1), mediumPriority (2), lowPriority (3) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object define the priority of connection. The first parameter affects the transmition of cells in Conjested network is the Service Category( Cbr has the highest priority and then Vbr,Ubr ) In connections with the same category this object will define the priority." ::= { atmEtherCnfgEntry 12 } atmEtherCnfgRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object is used to create a new row or modify or delete an existing row in this table." ::= { atmEtherCnfgEntry 13 } atmEtherCnfgRouterIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "The interface IP address for SNMP requests." ::= { atmEtherCnfgEntry 14 } atmEtherCnfgRouterMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "The interface IP address mask for SNMP requests." ::= { atmEtherCnfgEntry 15 } atmEtherCnfgRouterFragmentation OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3), notApplicable (255) } MAX-ACCESS read-create STATUS current DESCRIPTION "Fragmentation. When application is not router value must be 'notApplicable'." ::= { atmEtherCnfgEntry 16 } atmEtherCnfgRouterRIPMode OBJECT-TYPE SYNTAX INTEGER { rip1 (1), rip2 (2), rip1And2 (3), none (4), notApplicable (255) } MAX-ACCESS read-create STATUS current DESCRIPTION "RIP Mode. When application is not router value must be 'notApplicable'." ::= { atmEtherCnfgEntry 17 } atmEtherCnfgRouterMTU OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS deprecated DESCRIPTION " ." ::= { atmEtherCnfgEntry 18 } atmEtherCnfgPPPEncapsulation OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), none (2), rfc1483 (3), pppVcMuxed (4), pppLlcMuxed (5) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object define the encapsulation type requested for the connection. rfc1483 - Multiprotocol Encapsulation over ATM Adaptation Layer 5 (no PPP) PPP VC Muxed - For VC Based Multiplexing, the carried network interconnect protocol is identified implicitly by the VC connecting the two ATM stations, i.e. each protocol must be carried over a separate VC. There is therefore no need to include explicit multiplexing information in the Payload of the AAL5 CPCS-PDU. This results in minimal bandwidth and processing overhead. PPP LLC Muxed - LLC (Low layer compatibility) Encapsulation is needed when several protocols are carried over the same VC. In order to allow the receiver to properly process the incoming AAL5 CPCS-PDU, the Payload Field must contain information necessary to identify the protocol of the routed or bridged PDU. In LLC Encapsulation this informationis encoded in an LLC header placed in front of the carried PDU." DEFVAL { rfc1483 } ::= { atmEtherCnfgEntry 19 } atmEtherCnfgAllocatedBuffers OBJECT-TYPE SYNTAX Integer32 (10..217) MAX-ACCESS read-create STATUS current DESCRIPTION "This object enables user to limit the amount of buffers used by the connection. The limit set by this object will give the effect of a virtual buffer pool per connection. The user can allocate between 10 to 217 buffers to every connection. By default the limit is 50 buffers. Sum of limits allocated to all connections must not exceed the total amount of available buffers. Whenever a connection exceeds it's buffer limit due to congestion or burst traffic is discarded" DEFVAL { 50 } ::= { atmEtherCnfgEntry 20 } -- ************************************************************* -- RAD ATM's index to User port's index Translation table -- ************************************************************* atmSuCrossConnectTranslate OBJECT IDENTIFIER ::= { atmSuCrossConnect 5 } atmTranslateTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmTranslateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table translates the three of AtmIfIndex,AtmVpi,AtmVci to ifIndex of the interface on the user port's side." ::= { atmSuCrossConnectTranslate 1 } atmTranslateEntry OBJECT-TYPE SYNTAX AtmTranslateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry includes the User side interface's ifIndex of any virtual connection along with the ATM connection indices." INDEX { atmTranslateAtmIfIndex, atmTranslateAtmVpi, atmTranslateAtmVci } ::= { atmTranslateTable 1 } AtmTranslateEntry ::= SEQUENCE { atmTranslateAtmIfIndex Integer32, atmTranslateAtmVpi Integer32, atmTranslateAtmVci Integer32, atmTranslateUserIfIndex Integer32 } atmTranslateAtmIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The ifIndex associated to the ATM interface." ::= { atmTranslateEntry 1 } atmTranslateAtmVpi OBJECT-TYPE SYNTAX Integer32 (1..4095) MAX-ACCESS read-only STATUS current DESCRIPTION "The Vpi number of the ATM end point." ::= { atmTranslateEntry 2 } atmTranslateAtmVci OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The Vci number of the ATM end point." ::= { atmTranslateEntry 3 } atmTranslateUserIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The ifIndex associated to the user interface." ::= { atmTranslateEntry 4 } -- ************************************************************* -- ************************************************************* -- Traps -- ************************************************************* -- ************************************************************* --NOTIFICATIONS radAtmEvents OBJECT-IDENTITY STATUS current DESCRIPTION "The events for RAD ATM." ::= { radAtm 0 } alarmTrap NOTIFICATION-TYPE STATUS current DESCRIPTION "This trap is sent whenever an alarm occurs in the agent." ::= { radAtmEvents 1 } statusChangeTrap NOTIFICATION-TYPE OBJECTS { agnLed, agnIndication } STATUS current DESCRIPTION "This trap is sent whenever a led in the agent change it's status." ::= { radAtmEvents 2 } END -- -- file :v:\doc\rdv\mib\ver485\radsonet.txt -- RAD-SONET-MIB DEFINITIONS ::= BEGIN --Title: RAD-SONET MIB -- -- IMPORTS -- Gauge32 FROM RFC1155-SMI -- ifIndex FROM RFC1213-MIB -- OBJECT-TYPE FROM RFC-1212 -- radWan FROM RAD-GEN-MIB; -- RAD-SONET MIB --Title: RAD's SONET INTERFACE MIB --Version: 1.0 --Date: 13.10.96 --By: Yair Arian --File: sonet.mib -- --Last update: 02-May-2002 by Smadar Tauber sonetInterface OBJECT IDENTIFIER ::= {diverseIfWanGen 2} prtSonetPerfHistory OBJECT IDENTIFIER ::= {sonetInterface 1} -- The SONET Medium Table prtSonetMediumTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtSonetMediumEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The SONET Medium table." ::= { prtSonetPerfHistory 1 } prtSonetMediumEntry OBJECT-TYPE SYNTAX PrtSonetMediumEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the SONET Medium table. ifIndex of the lowest SONET layer of type sonet(39)." INDEX { ifIndex } ::= { prtSonetMediumTable 1 } PrtSonetMediumEntry ::= SEQUENCE { prtSonetMediumTimeElapsed Integer32, prtSonetMediumValidIntervals Integer32 } prtSonetMediumTimeElapsed OBJECT-TYPE SYNTAX Integer32 (0..899) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of seconds that have elapsed since the beginning of the near end current error- measurement period." ::= { prtSonetMediumEntry 1 } prtSonetMediumValidIntervals OBJECT-TYPE SYNTAX Integer32 (0..96) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of previous near end intervals for which valid data was collected. The value will be 96 unless the interface was brought online within the last 24 hours, in which case the value will be the number of complete 15 minute near end intervals since the interface has been online." ::= { prtSonetMediumEntry 2 } -- The SONET Section/Line Current Table -- The SONET Section/Line Current table contains various statistics being -- collected for the current 15 minute interval. prtSonetSectionLineCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtSectionLineCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The SONET Section/Line Current table." ::= { prtSonetPerfHistory 2 } prtSectionLineCurrentEntry OBJECT-TYPE SYNTAX PrtSectionLineCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the SONET Section/Line Current table. ifIndex of the section/line SONET layer of type sonet(39)." INDEX { ifIndex } ::= { prtSonetSectionLineCurrentTable 1 } PrtSectionLineCurrentEntry ::= SEQUENCE { prtSonetCurrentLOS Gauge32, prtSonetCurrentLOF Gauge32, prtSonetCurrentLineAIS Gauge32, prtSonetCurrentLineFERF Gauge32, prtSonetCurrentSectionBIP Gauge32, prtSonetCurrentLineBIP Gauge32, prtSonetCurrentLineFEBE Gauge32, prtSonetCurrentUAS Gauge32, prtSonetCurrentSES Gauge32, prtSonetCurrentES Gauge32, prtSonetCurrentStatus OCTET STRING, prtSonetCurrentLSV Gauge32 } prtSonetCurrentLOS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of LOS seconds, encountered by a SONET interface in the current 15 minute interval." ::= { prtSectionLineCurrentEntry 1 } prtSonetCurrentLOF OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of LOF seconds, encountered by a SONET interface in the current 15 minute interval." ::= { prtSectionLineCurrentEntry 2 } prtSonetCurrentLineAIS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Line AIS seconds, encountered by a SONET interface in the current 15 minute interval." ::= { prtSectionLineCurrentEntry 3 } prtSonetCurrentLineFERF OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Line FERF seconds, encountered by a SONET interface in the current 15 minute interval." ::= { prtSectionLineCurrentEntry 4 } prtSonetCurrentSectionBIP OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Section BIP errors, encountered by a SONET interface in the current 15 minute interval." ::= { prtSectionLineCurrentEntry 5 } prtSonetCurrentLineBIP OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Line BIP errors, encountered by a SONET interface in the current 15 minute interval." ::= { prtSectionLineCurrentEntry 6 } prtSonetCurrentLineFEBE OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Line FEBE errors, encountered by a SONET interface in the current 15 minute interval." ::= { prtSectionLineCurrentEntry 7 } prtSonetCurrentUAS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of UAS encountered by a SONET interface in the current 15 minute interval." ::= { prtSectionLineCurrentEntry 8 } prtSonetCurrentSES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of SES encountered by a SONET interface in the current 15 minute interval." ::= { prtSectionLineCurrentEntry 9 } prtSonetCurrentES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Errored Seconds, encountered by a SONET interface in the current 15 minute interval." ::= { prtSectionLineCurrentEntry 10 } prtSonetCurrentStatus OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) MAX-ACCESS read-only STATUS current DESCRIPTION "The statuses of the current interval: 0 - O.K. 1 - The link has been switched by a redundancy mechanism. 2 - Module is in/out. 4 - Empty - card is out." ::= { prtSectionLineCurrentEntry 11 } prtSonetCurrentLSV OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of LSV seconds (Line Symbol Violation), encountered by a SONET interface in the current 15 minute interval." ::= { prtSectionLineCurrentEntry 12 } -- The SONET Section/Line interface Interval -- The SONET Section/Line Interval Table contains various statistics -- collected by the Interface over the previous 24 -- hours of operation. The past 24 hours are broken into 96 -- completed 15 minute intervals. prtSonetSectionLineIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtSectionLineIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Section/Line Interval table." ::= { prtSonetPerfHistory 3 } prtSectionLineIntervalEntry OBJECT-TYPE SYNTAX PrtSectionLineIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the SONET Section/Line Interval table. ifIndex of the section/line SONET layer of type sonet(39)." INDEX { ifIndex, prtSonetLineIntervalNumber } ::= { prtSonetSectionLineIntervalTable 1 } PrtSectionLineIntervalEntry ::= SEQUENCE { prtSonetLineIntervalNumber Integer32, prtSonetIntervalLOS Gauge32, prtSonetIntervalLOF Gauge32, prtSonetIntervalLineAIS Gauge32, prtSonetIntervalLineFERF Gauge32, prtSonetIntervalSectionBIP Gauge32, prtSonetIntervalLineBIP Gauge32, prtSonetIntervalLineFEBE Gauge32, prtSonetIntervalUAS Gauge32, prtSonetIntervalSES Gauge32, prtSonetIntervalES Gauge32, prtSonetIntervalStatus OCTET STRING, prtSonetIntervalLSV Gauge32 } prtSonetLineIntervalNumber OBJECT-TYPE SYNTAX Integer32 (1..96) MAX-ACCESS read-only STATUS current DESCRIPTION "A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid)." ::= { prtSectionLineIntervalEntry 1 } prtSonetIntervalLOS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of LOS seconds , encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals." ::= { prtSectionLineIntervalEntry 2 } prtSonetIntervalLOF OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of LOF seconds, encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals." ::= { prtSectionLineIntervalEntry 3 } prtSonetIntervalLineAIS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Line AIS seconds, encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals." ::= { prtSectionLineIntervalEntry 4 } prtSonetIntervalLineFERF OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Line FERF seconds, encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals." ::= { prtSectionLineIntervalEntry 5 } prtSonetIntervalSectionBIP OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Section BIP errors, encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals." ::= { prtSectionLineIntervalEntry 6 } prtSonetIntervalLineBIP OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Line BIP errors, encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals." ::= { prtSectionLineIntervalEntry 7 } prtSonetIntervalLineFEBE OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Line FEBE errors, encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals." ::= { prtSectionLineIntervalEntry 8 } prtSonetIntervalUAS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of UAS encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals." ::= { prtSectionLineIntervalEntry 9 } prtSonetIntervalSES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of SES encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals." ::= { prtSectionLineIntervalEntry 10 } prtSonetIntervalES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Errored Seconds, encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals." ::= { prtSectionLineIntervalEntry 11 } prtSonetIntervalStatus OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) MAX-ACCESS read-only STATUS current DESCRIPTION " The statuses of the current interval: 0 - O.K. 1 - The link has been switched by a redundancy mechanism. 2 - Module is in/out. 4 - Empty - card is out." ::= { prtSectionLineIntervalEntry 12 } prtSonetIntervalLSV OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of LSV seconds (Line Symbol Violation), encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals." ::= { prtSectionLineIntervalEntry 13 } -- The SONET Path Current Table -- The SONET Path Current table contains various statistics being -- collected for the current 15 minute interval. prtSonetPathCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtPathCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The SONET Path Current table." ::= { prtSonetPerfHistory 4 } prtPathCurrentEntry OBJECT-TYPE SYNTAX PrtPathCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the SONET Path Current table. ifIndex of the Path SONET layer of type sonetPath(50)." INDEX { ifIndex } ::= { prtSonetPathCurrentTable 1 } PrtPathCurrentEntry ::= SEQUENCE { prtSonetCurrentPathAIS Gauge32, prtSonetCurrentPathFERF Gauge32, prtSonetCurrentLOP Gauge32, prtSonetCurrentSLM Gauge32, prtSonetCurrentLOC Gauge32, prtSonetCurrentPathBIP Gauge32, prtSonetCurrentPathFEBE Gauge32 } prtSonetCurrentPathAIS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Path AIS seconds, encountered by a SONET interface in the current 15 minute interval." ::= { prtPathCurrentEntry 1 } prtSonetCurrentPathFERF OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Path FERF seconds, encountered by a SONET interface in the current 15 minute interval." ::= { prtPathCurrentEntry 2 } prtSonetCurrentLOP OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number LOP seconds, encountered by a SONET interface in the current 15 minute interval." ::= { prtPathCurrentEntry 3 } prtSonetCurrentSLM OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of SLM seconds, encountered by a SONET interface in the current 15 minute interval." ::= { prtPathCurrentEntry 4 } prtSonetCurrentLOC OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of LOC seconds, encountered by a SONET interface in the current 15 minute interval." ::= { prtPathCurrentEntry 5 } prtSonetCurrentPathBIP OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Path BIP errors, encountered by a SONET interface in the current 15 minute interval." ::= { prtPathCurrentEntry 6 } prtSonetCurrentPathFEBE OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Path FEBE errors, encountered by a SONET interface in the current 15 minute interval." ::= { prtPathCurrentEntry 7 } -- The SONET Path interface Interval -- The SONET Path Interval Table contains various statistics -- collected by the Interface over the previous 24 -- hours of operation. The past 24 hours are broken into 96 -- completed 15 minute intervals. prtSonetPathIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtPathIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Path Interval table." ::= { prtSonetPerfHistory 5 } prtPathIntervalEntry OBJECT-TYPE SYNTAX PrtPathIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the SONET Path Interval table." INDEX { ifIndex, prtSonetPathIntervalNumber } ::= { prtSonetPathIntervalTable 1 } PrtPathIntervalEntry ::= SEQUENCE { prtSonetPathIntervalNumber Integer32, prtSonetIntervalPathAIS Gauge32, prtSonetIntervalPathFERF Gauge32, prtSonetIntervalLOP Gauge32, prtSonetIntervalSLM Gauge32, prtSonetIntervalLOC Gauge32, prtSonetIntervalPathBIP Gauge32, prtSonetIntervalPathFEBE Gauge32 } prtSonetPathIntervalNumber OBJECT-TYPE SYNTAX Integer32 (1..96) MAX-ACCESS read-only STATUS current DESCRIPTION "A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid)." ::= { prtPathIntervalEntry 1 } prtSonetIntervalPathAIS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Path AIS seconds , encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals." ::= { prtPathIntervalEntry 2 } prtSonetIntervalPathFERF OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Path FERF seconds, encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals." ::= { prtPathIntervalEntry 3 } prtSonetIntervalLOP OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of LOP seconds, encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals." ::= { prtPathIntervalEntry 4 } prtSonetIntervalSLM OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of SLM seconds, encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals." ::= { prtPathIntervalEntry 5 } prtSonetIntervalLOC OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of LOC seconds, encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals." ::= { prtPathIntervalEntry 6 } prtSonetIntervalPathBIP OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Path BIP errors, encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals." ::= { prtPathIntervalEntry 7 } prtSonetIntervalPathFEBE OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Path FEBE errors, encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals." ::= { prtPathIntervalEntry 8 } prtSonetConfig OBJECT IDENTIFIER ::= {sonetInterface 2} prtSonetGen OBJECT IDENTIFIER ::= {prtSonetConfig 1} prtSonetGenTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtSonetGenEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Sonet/SDH general port configuration table." ::= { prtSonetGen 1} prtSonetGenEntry OBJECT-TYPE SYNTAX PrtSonetGenEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " An entry in the Sonet/SDH general port configuration table." INDEX { prtSonetGenCnfgIdx, prtSonetGenIdx } ::= { prtSonetGenTable 1} PrtSonetGenEntry ::= SEQUENCE { prtSonetGenCnfgIdx Integer32, prtSonetGenIdx Integer32, prtSonetGenSdThreshold INTEGER, prtSonetGenEedThreshold INTEGER } prtSonetGenCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config. For products that support several configurations, Set can be performed only to the Temporary Config (=255). " ::= { prtSonetGenEntry 1} prtSonetGenIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a unique port or interface number. For numbering, see product's spec. For some products, the numbering can equal ifIndex." ::= { prtSonetGenEntry 2} prtSonetGenSdThreshold OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), n3 (3), n4 (4), n5 (5), n6 (6), n7 (7), n8 (8), n9 (9) } MAX-ACCESS read-write STATUS current DESCRIPTION "SD=Signal Degraded Threshold. Units: [10E-]. The threshold is 10E-x relative to the frequency of the data flow. x=3, 4, 5, 6, 7, 8, 9. n3= 10E-3 n4= 10E-4 n5= 10E-5 n6= 10E-6 n7= 10E-7 n8= 10E-8 n9= 10E-9 ." ::= { prtSonetGenEntry 3 } prtSonetGenEedThreshold OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), n3 (3), n4 (4), n5 (5), n6 (6), n7 (7), n8 (8), n9 (9) } MAX-ACCESS read-write STATUS current DESCRIPTION "EED=Excessive Error Defect Threshold. Units: [10E-]. The threshold is 10E-x relative to the frequency of the data flow. x=3, 4, 5, 6, 7, 8, 9. n3= 10E-3 n4= 10E-4 n5= 10E-5 n6= 10E-6 n7= 10E-7 n8= 10E-8 n9= 10E-9 ." ::= { prtSonetGenEntry 4 } --STM-1 ports prtSonetStm1 OBJECT IDENTIFIER ::= {prtSonetConfig 2} prtSonetStm1Table OBJECT-TYPE SYNTAX SEQUENCE OF PrtSonetStm1Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Sonet/SDH STM-1 port configuration table." ::= { prtSonetStm1 1} prtSonetStm1Entry OBJECT-TYPE SYNTAX PrtSonetStm1Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION " An entry in the Sonet/SDH STM-1 port configuration table." INDEX { prtSonetStm1CnfgIdx, prtSonetStm1Idx } ::= { prtSonetStm1Table 1} PrtSonetStm1Entry ::= SEQUENCE { prtSonetStm1CnfgIdx Integer32, prtSonetStm1Idx Integer32, prtSonetStm1ClockSrc INTEGER, prtSonetStm1DccMode INTEGER, prtSonetStm1RoutingProt INTEGER, prtSonetStm1MngProt INTEGER, prtSonetStm1OperationalMode INTEGER } prtSonetStm1CnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config. For products that support several configurations, Set can be performed only to the Temporary Config (=255). " ::= { prtSonetStm1Entry 1} prtSonetStm1Idx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a unique port or interface number. For numbering, see product's spec. For some products, the numbering can equal ifIndex." ::= { prtSonetStm1Entry 2} prtSonetStm1ClockSrc OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), internal (2), lbt (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Clock Source of the STM-1 port. lbt = Loop Back Timing." ::= { prtSonetStm1Entry 3 } prtSonetStm1DccMode OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), none (2), d1ToD3 (3), d4ToD12 (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "DCC Mode. DCC=Data Communication Channel. d1ToD3 = D1-D3 bytes are used (RS=Regeneration Section). d4ToD12= D4-D12 bytes are used (MS=Multiplexing Section)." ::= { prtSonetStm1Entry 4 } prtSonetStm1RoutingProt OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), none (2), proprietary (3), rip2 (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Routing Protocol." ::= { prtSonetStm1Entry 5 } prtSonetStm1MngProt OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), -- none (2) proprietary (3), -- rip2 (4) ppp (5), frameRelay (6) } MAX-ACCESS read-write STATUS current DESCRIPTION "Management Protocol over DCC: Proprietary, PPP or Frame Relay." ::= { prtSonetStm1Entry 6 } prtSonetStm1OperationalMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), terminal (2), linear (3), linearProtection (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Operational Mode. linear - cannot be selected when there is Redundancy between the STM-1 ports." ::= { prtSonetStm1Entry 7 } --SONET/SDH VC-4 and VC-12 ports parameters prtSonetVc OBJECT IDENTIFIER ::= {prtSonetConfig 3} prtSonetVcTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtSonetVcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Sonet/SDH VC port configuration table." ::= { prtSonetVc 1} prtSonetVcEntry OBJECT-TYPE SYNTAX PrtSonetVcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " An entry in the Sonet/SDH VC port configuration table." INDEX { prtSonetVcCnfgIdx, prtSonetVcIdx } ::= { prtSonetVcTable 1} PrtSonetVcEntry ::= SEQUENCE { prtSonetVcCnfgIdx Integer32, prtSonetVcIdx Integer32, prtSonetVcJTxPathTraceEnable INTEGER, prtSonetVcJRxPathTraceEnable INTEGER, prtSonetVcJPathTrace DisplayString, prtSonetVcConnect INTEGER } prtSonetVcCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config. For products that support several configurations, Set can be performed only to the Temporary Config (=255). " ::= { prtSonetVcEntry 1} prtSonetVcIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a unique port or interface number. For numbering, see product's spec. For some products, the numbering can equal ifIndex." ::= { prtSonetVcEntry 2} prtSonetVcJTxPathTraceEnable OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable Transmitting Jy Path Trace. y=1, 2: J1 - for VC-4 layer J2 - for VC-12 layer." ::= { prtSonetVcEntry 3 } prtSonetVcJRxPathTraceEnable OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable checking Jy Path Trace. y=1, 2: J1 - for VC-4 layer J2 - for VC-12 layer." ::= { prtSonetVcEntry 4 } prtSonetVcJPathTrace OBJECT-TYPE SYNTAX DisplayString (SIZE(0..16)) MAX-ACCESS read-write STATUS current DESCRIPTION "Jy Path Trace. y=1, 2: J1 - for VC-4 layer J2 - for VC-12 layer. This object is applicable only if one of the previous 2 objects is 'enable'." ::= { prtSonetVcEntry 5 } prtSonetVcConnect OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Connect VCn (n - 11,12,2,3,4) port (yes/no)." ::= { prtSonetVcEntry 6 } --TU-12 (within VC-4) Connect Table prtSonetTuTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtSonetTuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table's Objects is valid only for the TmpCnfg entry (Scratch)." ::= { prtSonetVc 2} prtSonetTuEntry OBJECT-TYPE SYNTAX PrtSonetTuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtSonetTuCnfgIdx, prtSonetTuPrtIdx, prtSonetTuIdx, prtSonetTuConPrtIdx } ::= { prtSonetTuTable 1} PrtSonetTuEntry ::= SEQUENCE { prtSonetTuCnfgIdx Integer32, prtSonetTuPrtIdx Integer32, prtSonetTuIdx Integer32, prtSonetTuConPrtIdx Integer32, prtSonetTuType INTEGER, prtSonetTuMode INTEGER, prtSonetTuRowStatus RowStatus } prtSonetTuCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config. For products that support several configurations, Set can be performed only to the Temporary Config (=255). " ::= { prtSonetTuEntry 1} prtSonetTuPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a unique port or interface number. For port numbering, see product's spec. For some products, the numbering can equal ifIndex." ::= { prtSonetTuEntry 2} prtSonetTuIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a unique TU (Tributary Unit) within VC-4. The valid TUs are 1..63." ::= { prtSonetTuEntry 3} prtSonetTuConPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the connected port, when prtSonetTuType=connect. For port numbering, see product's spec. For some products, the numbering can equal ifIndex. notApplicable - will be indicated as 100." ::= {prtSonetTuEntry 4} prtSonetTuType OBJECT-TYPE SYNTAX INTEGER { connect (2), bypass (3) } MAX-ACCESS read-create STATUS current DESCRIPTION "The type of TU (Tributary Unit). connect - connected to one of the E1 ports. bypass - bypassed to the other VC4 port. TUs that are not connected or bypassed, will not exist in this table." ::= { prtSonetTuEntry 5} prtSonetTuMode OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), addAndDrop (2), add (3) } MAX-ACCESS read-create STATUS current DESCRIPTION "TU Mode of connection. addAndDrop - Add & Drop add - Add (TU receives from the E1 ports)." ::= { prtSonetTuEntry 6} prtSonetTuRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Creation/Deletion of rows in the table." ::= { prtSonetTuEntry 7} -- SDH Cross Connect Table -- May be used also for SONET prtSonetXConnect OBJECT IDENTIFIER ::= {sonetInterface 3} prtSonetXConnectTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtSonetXConnectEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table's Objects is valid only for the TmpCnfg entry (Scratch)." ::= { prtSonetXConnect 1} prtSonetXConnectEntry OBJECT-TYPE SYNTAX PrtSonetXConnectEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { prtSonetXConnectCnfgIdx, prtSonetXConnectPrtIdx, prtSonetXConnectConPrtIdx, prtSonetXConnectAUGIdx, prtSonetXConnectTUG3Idx, prtSonetXConnectTUG2Idx, prtSonetXConnectTUnIdx } ::= { prtSonetXConnectTable 1} PrtSonetXConnectEntry ::= SEQUENCE { prtSonetXConnectCnfgIdx Integer32, prtSonetXConnectPrtIdx Integer32, prtSonetXConnectConPrtIdx Integer32, prtSonetXConnectAUGIdx Integer32, prtSonetXConnectTUG3Idx Integer32, prtSonetXConnectTUG2Idx Integer32, prtSonetXConnectTUnIdx Integer32, prtSonetXConnectRowStatus RowStatus, prtSonetXConnectDirection INTEGER, prtSonetXConnectTuNumber INTEGER } prtSonetXConnectCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config. For products that support several configurations, Set can be performed only to the Temporary Config (=255). " ::= { prtSonetXConnectEntry 1} prtSonetXConnectPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a unique port or interface number. For port numbering, see product's spec. For some products, the numbering can equal ifIndex." ::= { prtSonetXConnectEntry 2} prtSonetXConnectConPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the connected port. For port numbering, see product's spec. For some products, the numbering can equal ifIndex. notApplicable - will be indicated as 255." ::= {prtSonetXConnectEntry 3} prtSonetXConnectAUGIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates an AUG (Administrative Unit Group) within STM-N. The valid AUGs values are: 1 for STM-1 1...4 for STM-4, 1..16 for STM-16 and 1..64 for STM-64 (STM-64) 255 designates NA." ::= { prtSonetXConnectEntry 4} prtSonetXConnectTUG3Idx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a TUG-3 (Tributary Unit Group 3) within VC-4. The valid TUG3s are values are 1..3. and 255 which designates NA " ::= { prtSonetXConnectEntry 5} prtSonetXConnectTUG2Idx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a TUG2 (Tributary Unit Group 2 ) within VC-3. The valid TUG2's values are 1..7 and 255 which designates NA " ::= { prtSonetXConnectEntry 6} prtSonetXConnectTUnIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a TUn within TUG-2 or TUG-3 (Tributary Unit n, where n is 2, 12 or 11 within TUG-2, or 3 within TUG-3) valid values are 1 for TU-2 1 for TU-3 1..4 for TU-11 1..3 for TU-12 255 designates NA" ::= { prtSonetXConnectEntry 7} prtSonetXConnectRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Creation/Deletion of rows in the table." ::= { prtSonetXConnectEntry 8} prtSonetXConnectDirection OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), rx (2), tx (3), both (4) } MAX-ACCESS read-create STATUS current DESCRIPTION "TU direction of connection. rx=Drop tx=Add both = Add & Drop " ::= { prtSonetXConnectEntry 9} prtSonetXConnectTuNumber OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), tu2 (2), tu3 (3), tu11 (4), tu12 (5) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates which TU is used in prtSonetXConnectTUnIdx " ::= { prtSonetXConnectEntry 10} END -- -- file :v:\doc\rdv\mib\ver485\radds1.txt -- RAD-DS1-MIB DEFINITIONS ::= BEGIN --Title: RAD-DS1 MIB -- -- Copyright 1998 RAD Data Communications, Ltd. -- All Rights Reserved. -- IMPORTS -- PerfCurrentCount, PerfIntervalCount FROM PerfHist-TC-MIB; -- OBJECT-TYPE FROM RFC-1212 -- radWan FROM RAD-GEN-MIB; -- RAD-DS1 MIB --Title: RAD's DS1 INTERFACE MIB --Version: 1.0 --Date: 03.02.98 --By: Ilana Schvetz --File: radds1.mib -- Last updated by Smadar Tauber 01-Oct-2002 ds1Interface OBJECT IDENTIFIER ::= {diverseIfWanGen 4} prtDs1PerfHistory OBJECT IDENTIFIER ::= {ds1Interface 1} -- Extension to the dsx1 current table dsx1XCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF Dsx1XCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of current statistics entries. This table contains additional objects for the current table." ::= { prtDs1PerfHistory 2 } dsx1XCurrentEntry OBJECT-TYPE SYNTAX Dsx1XCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing additional statistical counters applicable to a particular current table." -- AUGMENTS { dsx1CurrentEntry } INDEX { dsx1CurrentIndex } ::= { dsx1XCurrentTable 1 } Dsx1XCurrentEntry ::= SEQUENCE { dsx1CurrentLOS PerfCurrentCount, dsx1CurrentLOF PerfCurrentCount, dsx1CurrentLOC PerfCurrentCount, dsx1CurrentAIS PerfCurrentCount, dsx1CurrentRAI PerfCurrentCount, dsx1CurrentLOMF PerfCurrentCount, dsx1CurrentFEBE PerfCurrentCount, dsx1CurrentStatus OCTET STRING, dsx1CurrentBPV PerfCurrentCount, dsx1CurrentLOCRCMF PerfCurrentCount, dsx1CurrentLOFC PerfCurrentCount, dsx1CurrentCRCErrors PerfCurrentCount } dsx1CurrentLOS OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of LOS seconds, encountered by a DS1 interface in the current 15 minute interval." ::= { dsx1XCurrentEntry 1 } dsx1CurrentLOF OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of LOF seconds, encountered by a DS1 interface in the current 15 minute interval." ::= { dsx1XCurrentEntry 2 } dsx1CurrentLOC OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION " Loss Of Cell delineation. Counts number of cells the ATM UNI cells receiver lost cells delineation ." ::= { dsx1XCurrentEntry 3 } dsx1CurrentAIS OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of AIS seconds, encountered by a DS1 interface in the current 15 minute interval." ::= { dsx1XCurrentEntry 4 } dsx1CurrentRAI OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "Remote Alarm Indication: Transmitted in the outgoing direction (toward the PABX) over FDL bits when the DS1 device detected an incoming Loss Of Frame. Received from the far end (PABX) over FDL when it detects a Loss of frame." ::= { dsx1XCurrentEntry 5 } dsx1CurrentLOMF OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "Loss of Multi-Frame sequence in E1 time slot 16." ::= { dsx1XCurrentEntry 6 } dsx1CurrentFEBE OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "Far End Block Errors, as reported in the first bit of frames 13 and 15, on multiframe E1 lines with CRC4, in the current 15 minute interval." ::= { dsx1XCurrentEntry 7 } dsx1CurrentStatus OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) MAX-ACCESS read-only STATUS current DESCRIPTION "The statuses of the current interval: 0 - Valid. 1 - redundantLinkSwitch - the link has been switched by a redundancy mechanism. 2 - discontinuity - module was partialy out. 4 - notValid - module is out." ::= { dsx1XCurrentEntry 8 } dsx1CurrentBPV OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of BPVs (Bi-Polar Violations) encountered by a DS1 interface in the current 15 minute interval." ::= { dsx1XCurrentEntry 9 } dsx1CurrentLOCRCMF OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "Loss of CRC4 Multi-Frame sequence in E1. encountered in the current 15 minute interval" ::= { dsx1XCurrentEntry 10 } dsx1CurrentLOFC OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "Counts the number of loss of frame events measured. encountered in the current 15 minute interval" ::= { dsx1XCurrentEntry 11 } dsx1CurrentCRCErrors OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "Counts the number of CRC error events, encountered in the current 15 minute interval." ::= { dsx1XCurrentEntry 12 } -- Interval table dsx1XIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF Dsx1XIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " A list of Interval entries. This table contains additional objects for the interval table." ::= { prtDs1PerfHistory 3 } dsx1XIntervalEntry OBJECT-TYPE SYNTAX Dsx1XIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing additional statistical counters applicable to a particular interval table." -- AUGMENTS { dsx1IntervalEntry } INDEX { dsx1IntervalIndex, dsx1IntervalNumber } ::= { dsx1XIntervalTable 1 } Dsx1XIntervalEntry ::= SEQUENCE { dsx1IntervalLOS PerfIntervalCount, dsx1IntervalLOF PerfIntervalCount, dsx1IntervalLOC PerfIntervalCount, dsx1IntervalAIS PerfIntervalCount, dsx1IntervalRAI PerfIntervalCount, dsx1IntervalLOMF PerfIntervalCount, dsx1IntervalFEBE PerfIntervalCount, dsx1IntervalStatus OCTET STRING, dsx1IntervalBPV PerfIntervalCount, dsx1IntervalLOCRCMF PerfIntervalCount, dsx1IntervalLOFC PerfIntervalCount } dsx1IntervalLOS OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of LOS seconds , encountered by a DS1 interface in one of the previous 96, individual 15 minute, intervals." ::= { dsx1XIntervalEntry 1 } dsx1IntervalLOF OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of OOF seconds, encountered by a DS1 interface in one of the previous 96, individual 15 minute, intervals." ::= { dsx1XIntervalEntry 2 } dsx1IntervalLOC OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION " Loss Of Cell delineation. Counts number of cells the ATM UNI cells receiver lost cells delineation ." ::= { dsx1XIntervalEntry 3 } dsx1IntervalAIS OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of AIS seconds, encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals." ::= { dsx1XIntervalEntry 4 } dsx1IntervalRAI OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "Remote Alarm Indication: Transmitted in the outgoing direction (toward the PABX) over FDL bits when the DS1 device detected an incoming Loss Of Frame. Received from the far end (PABX) over FDL when it detects a Loss of frame." ::= { dsx1XIntervalEntry 5 } dsx1IntervalLOMF OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "Loss of Multi-Frame sequence in E1 time slot 16." ::= { dsx1XIntervalEntry 6 } dsx1IntervalFEBE OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "Far End Block Errors, as reported in the first bit of frames 13 and 15, on multiframe E1 lines with CRC4, in one of the previous 96, individual, 15 minute intervals." ::= { dsx1XIntervalEntry 7 } dsx1IntervalStatus OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) MAX-ACCESS read-only STATUS current DESCRIPTION "The statuses of the current interval: 0 - Valid. 1 - redundantLinkSwitch - the link has been switched by a redundancy mechanism. 2 - discontinuity - module was partialy out. 4 - notValid - module is out." ::= { dsx1XIntervalEntry 8 } dsx1IntervalBPV OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of BPV (Bi-Polar Violations) encountered by a DS1 interface in one of the previous 96, individual 15 minute, intervals." ::= { dsx1XIntervalEntry 9 } dsx1IntervalLOCRCMF OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "Loss of CRC4 Multi-Frame sequence in E1." ::= { dsx1XIntervalEntry 10 } dsx1IntervalLOFC OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "Counts the number of loss of frame events measured in one of the previous 96, individual 15 minute, intervals." ::= { dsx1XIntervalEntry 11 } -- Extension to the dsx1 Total table dsx1XTotalTable OBJECT-TYPE SYNTAX SEQUENCE OF Dsx1XTotalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of Total statistics entries. This table contains additional objects for the Total table." ::= { prtDs1PerfHistory 4 } dsx1XTotalEntry OBJECT-TYPE SYNTAX Dsx1XTotalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing additional statistical counters applicable to a particular current table." -- AUGMENTS { dsx1CurrentEntry } INDEX { dsx1TotalIndex } ::= { dsx1XTotalTable 1 } Dsx1XTotalEntry ::= SEQUENCE { dsx1TotalBPV PerfTotalCount, dsx1TotalLOFC PerfTotalCount } dsx1TotalBPV OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of BPV (Bi-Polar Violations) encountered by a DS1 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0." ::= { dsx1XTotalEntry 9 } dsx1TotalLOFC OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number loss of frames encountered by a DS1 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0." ::= { dsx1XTotalEntry 11 } -- Extension to the DS1 Configuration Table dsx1XConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Dsx1XConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " An extension to the DS1 Configuration table." ::= { ds1Interface 2 } dsx1XConfigEntry OBJECT-TYPE SYNTAX Dsx1XConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing additional configuration parameters." -- AUGMENTS { dsx1ConfigTable } INDEX { dsx1LineIndex } ::= { dsx1XConfigTable 1 } Dsx1XConfigEntry ::= SEQUENCE { dsx1IdleCode Integer32, dsx1LineMode INTEGER, dsx1dBTxGain INTEGER, dsx1RxSensitivity INTEGER, dsx1RestoreTime INTEGER, dsx1TcFirstSignal Integer32, dsx1TcSignal Integer32, dsx1TcPattern Integer32, dsx1Scramble INTEGER, dsx1LineAdaptiveTimingMode INTEGER, dsx1TxClockSource INTEGER, dsx1AisEnable INTEGER, dsx1TsEchoCancel OCTET STRING, dsx1EchoCancelerModule INTEGER, dsx1PortFunction INTEGER } dsx1IdleCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Byte pattern of the data received/transmitted in the E1T1 framer idle timeslots. Valid range: (0 - FF HEX)." ::= { dsx1XConfigEntry 1 } dsx1LineMode OBJECT-TYPE SYNTAX INTEGER { csu(1), dsu(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "T1 device operation mode. Valid for T1 only." ::= { dsx1XConfigEntry 2 } dsx1dBTxGain OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), neg75dB (2), neg15dB (3), neg225dB (4), zerodB (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Transmit line Gain for T1 CSU line mode." ::= { dsx1XConfigEntry 3 } dsx1RxSensitivity OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), neg10dB (2), neg32dB (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Determine the maximum attenuation of the receive signal that can be compensated for by the interface receive path. Not applicable for T1." ::= { dsx1XConfigEntry 4 } dsx1RestoreTime OBJECT-TYPE SYNTAX INTEGER { other(1), sec1(2), sec10(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Used to change the sync. algorithms to reduce the time required for the port to return to normal operation after a RED alarm." ::= { dsx1XConfigEntry 5 } dsx1TcFirstSignal OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Trunk conditioning signal - value to be sent as a signal during the first 2.5 seconds after alarm detection. Range is 0x0..0xF. 0xFF is a NULL value. Valid for T1 only." ::= { dsx1XConfigEntry 6 } dsx1TcSignal OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Trunk conditioning signal value after alarm detection. Range is 0x1..0xF for E1, and 0x0..0xF for T1." ::= { dsx1XConfigEntry 7 } dsx1TcPattern OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Trunk conditioning data pattern to be sent upon a DS0 fail. Range is 0x0..0xFF." ::= { dsx1XConfigEntry 8 } dsx1Scramble OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), notActive (2), active (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Scrambling is an operation that randomizes the bits of the payload of the ATM cell by a polynom. This operation helps with the error detection mechanism of the HEC. Not applicable for E1. active - will scramble/descramble the payload ATM cell notactive - will not scramble/descramble. " ::= { dsx1XConfigEntry 9 } dsx1LineAdaptiveTimingMode OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables end to end clock synchronization. Default value - off." ::= { dsx1XConfigEntry 10 } dsx1TxClockSource OBJECT-TYPE SYNTAX INTEGER { loopTiming(1), localTiming(2), throughTiming(3), adaptive(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The source of Transmit Clock. 'loopTiming' indicates that the recovered receive clock is used as the transmit clock. 'localTiming' indicates that a local clock source is used or when an external clock is attached to the box containing the interface. 'throughTiming' indicates that recovered receive clock from another interface is used as the transmit clock. 'adaptive' indicates that the clock is recovered according to the received data flow rate. " ::= { dsx1XConfigEntry 11 } dsx1AisEnable OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), disable(2), enable(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/ disable AIS transmit when Ethernet cable (for TDMoIP) is out (disconnected)." ::= { dsx1XConfigEntry 12 } dsx1TsEchoCancel OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter defines for each TS whether Echo-Cancellation is on. Each bit represents one TS as follow: First octet bit'0' = TS#1, bit'7' = TS#8, .. 2nd octet bit'0' = TS#9,.., 4th octet bit'7' = TS#32. Octets and bits order is from left to right: [31,30,..24] [23..16] [15..8] [7..0] MSB LSB MSB LSB MSB LSB MSB LSB For each bit values are: 0 - Echo-Cancellation off. 1 - Echo-Cancellation on." ::= { dsx1XConfigEntry 13 } dsx1EchoCancelerModule OBJECT-TYPE SYNTAX INTEGER { notExist(2), exist(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates whether echo-cancellation module exists for this line." ::= { dsx1XConfigEntry 14 } dsx1PortFunction OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), uni (2), ces (3), ima (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object determines the ATM Mode over the physical port. uni - The port will function as an ATM UNI. ces - The port will function as a CES. ima - The port will function as an IMA-ATM." ::= { dsx1XConfigEntry 15 } END -- -- file :v:\doc\rdv\mib\Before~1\radds3.txt -- RAD-DS3-MIB DEFINITIONS ::= BEGIN --Title: RAD-DS3 MIB -- -- Copyright 1993 RAD Data Communications, Ltd. -- All Rights Reserved. -- It is RAD's intent to encourage the widespread use of -- this Specification in connection with the management of -- RAD products. RAD grants vendors, end-users, -- and other interested parties a non-exclusive license to -- use this Specification in connection with the management -- of RAD products. -- This Specification is supplied "as is," and RAD makes -- no warranty, either express or implied, as to the use, -- operation, condition, or performance of the Specification. -- IMPORTS -- Gauge32 FROM SNMPv2-SMI -- ifIndex FROM SNMPv2-TC -- OBJECT-TYPE FROM SNMPv2-SMI -- radWan FROM RAD-GEN-MIB; -- RAD-DS3 MIB --Title: RAD's DS3 INTERFACE MIB --Version: 1.0 --Date: 13.10.96 --By: Yair Arian --File: ds3.mib -- --Last update: 27.01.98 by Ilana ds3Interface OBJECT IDENTIFIER ::= {diverseIfWanGen 3} prtDs3PerfHistory OBJECT IDENTIFIER ::= {ds3Interface 1} -- The DS3 Interface Table prtSDs3IfTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtDs3IfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The DS3 interface table." ::= { prtDs3PerfHistory 1 } prtDs3IfEntry OBJECT-TYPE SYNTAX PrtDs3IfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the DS3 interface table." INDEX { ifIndex } ::= { prtSDs3IfTable 1 } PrtDs3IfEntry ::= SEQUENCE { prtDs3IfTimeElapsed Integer32, prtDs3IfValidIntervals Integer32 } prtDs3IfTimeElapsed OBJECT-TYPE SYNTAX Integer32 (0..899) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of seconds that have elapsed since the beginning of the near end current error- measurement period." ::= { prtDs3IfEntry 1 } prtDs3IfValidIntervals OBJECT-TYPE SYNTAX Integer32 (0..96) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of previous near end intervals for which valid data was collected. The value will be 96 unless the interface was brought online within the last 24 hours, in which case the value will be the number of complete 15 minute near end intervals since the interface has been online." ::= { prtDs3IfEntry 2 } -- The DS3 Current Table -- The DS3 Current table contains various statistics being -- collected for the current 15 minute interval. prtDs3CurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtDs3CurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The DS3 Current table." ::= { prtDs3PerfHistory 2 } prtDs3CurrentEntry OBJECT-TYPE SYNTAX PrtDs3CurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the DS3 Current table." INDEX { ifIndex } ::= { prtDs3CurrentTable 1 } PrtDs3CurrentEntry ::= SEQUENCE { prtDs3CurrentLOS Gauge32, prtDs3CurrentOOF Gauge32, prtDs3CurrentLOC Gauge32, prtDs3CurrentAIS Gauge32, prtDs3CurrentRDI Gauge32, prtDs3CurrentUAS Gauge32, prtDs3CurrentBIP Gauge32, prtDs3CurrentFEBE Gauge32, prtDs3CurrentSLM Gauge32, prtDs3CurrentSES Gauge32, prtDs3CurrentES Gauge32, prtDs3CurrentBitParity Gauge32, prtDs3CurrentPlcpLOF Gauge32, prtDs3CurrentPlcpRAI Gauge32, prtDs3CurrentPlcpBIP Gauge32, prtDs3CurrentPlcpFEBE Gauge32, prtDs3CurrentBPV Gauge32, prtDs3CurrentLCE Gauge32, prtDs3CurrentStatus OCTET STRING } prtDs3CurrentLOS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of LOS seconds, encountered by a DS3 interface in the current 15 minute interval." ::= { prtDs3CurrentEntry 1 } prtDs3CurrentOOF OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of OOF seconds, encountered by a DS3 interface in the current 15 minute interval." ::= { prtDs3CurrentEntry 2 } prtDs3CurrentLOC OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of LOC seconds, encountered by a DS3 interface in the current 15 minute interval." ::= { prtDs3CurrentEntry 3 } prtDs3CurrentAIS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of AIS seconds, encountered by a DS3 interface in the current 15 minute interval." ::= { prtDs3CurrentEntry 4 } prtDs3CurrentRDI OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of RDI seconds, encountered by a DS3 interface." ::= { prtDs3CurrentEntry 5 } prtDs3CurrentUAS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of UAS, encountered by a SONET interface." ::= { prtDs3CurrentEntry 6 } prtDs3CurrentBIP OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of BIP errors, encountered by a DS3 interface in the current 15 minute interval." ::= { prtDs3CurrentEntry 7 } prtDs3CurrentFEBE OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of FEBE errors, encountered by a DS3 interface in the current 15 minute interval." ::= { prtDs3CurrentEntry 8 } prtDs3CurrentSLM OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of SLM seconds, encountered by an E3 (only ) interface in the current 15 minute interval." ::= { prtDs3CurrentEntry 9 } prtDs3CurrentSES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of SES encountered by a E3 interface in the current 15 minute interval." ::= { prtDs3CurrentEntry 10 } prtDs3CurrentES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION " The number of Errored Seconds, encountered by a DS3 interface in the current 15 minute interval." ::= { prtDs3CurrentEntry 11 } prtDs3CurrentBitParity OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Bit Parity Error counter. Relevant to T3 only." ::= { prtDs3CurrentEntry 12 } prtDs3CurrentPlcpLOF OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of LOF seconds, encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals. This counter is relevant for plcpInternal(5) or plcpExternal(6) configuration If frame types only." ::= { prtDs3CurrentEntry 13 } prtDs3CurrentPlcpRAI OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Receiving Yellow/Remote Alarm Indication. This counter is relevant for PLCP (external/internal) frame types only." ::= { prtDs3CurrentEntry 14 } prtDs3CurrentPlcpBIP OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION " The counter associated with the number of BIP errors, encountered by a DS3 interface in the current 15 minute interval. This counter is relevant for PLCP (external/internal) frame types only." ::= { prtDs3CurrentEntry 15 } prtDs3CurrentPlcpFEBE OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION " The counter associated with the number of FEBE errors, encountered by a DS3 interface in the current 15 minute interval. This counter is relevant for PLCP (external/internal) frame types only." ::= { prtDs3CurrentEntry 16 } prtDs3CurrentBPV OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of BPVs (Bi-Polar Violations) , encountered by a DS3 interface in the current 15 minute interval. This object is relevant only for Electrical Line of Fomi-E3/T3." ::= { prtDs3CurrentEntry 17 } prtDs3CurrentLCE OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of LCE (Link Code Errors) encountered by a DS3 interface in the current 15 minute interval. This object is relevant only for Optical Links of Fomi-E3/T3." ::= { prtDs3CurrentEntry 18 } prtDs3CurrentStatus OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) MAX-ACCESS read-only STATUS current DESCRIPTION "The statuses of the current interval: 0 - Valid. 1 - redundantLinkSwitch - the link has been switched by a redundancy mechanism. 2 - discontinuity - module was partialy out. 4 - notValid - module is out." ::= { prtDs3CurrentEntry 19 } -- The DS3 interface Interval -- The DS3 Interval Table contains various statistics -- collected by the Interface over the previous 24 -- hours of operation. The past 24 hours are broken into 96 -- completed 15 minute intervals. prtDs3IntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtDs3IntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The DS3 Interval table." ::= { prtDs3PerfHistory 3 } prtDs3IntervalEntry OBJECT-TYPE SYNTAX PrtDs3IntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the DS3 Interval table." INDEX { ifIndex, prtDs3IntervalNumber } ::= { prtDs3IntervalTable 1 } PrtDs3IntervalEntry ::= SEQUENCE { prtDs3IntervalNumber Integer32, prtDs3IntervalLOS Gauge32, prtDs3IntervalOOF Gauge32, prtDs3IntervalLOC Gauge32, prtDs3IntervalAIS Gauge32, prtDs3IntervalRDI Gauge32, prtDs3IntervalUAS Gauge32, prtDs3IntervalBIP Gauge32, prtDs3IntervalFEBE Gauge32, prtDs3IntervalSLM Gauge32, prtDs3IntervalSES Gauge32, prtDs3IntervalES Gauge32, prtDs3IntervalBitParity Gauge32, prtDs3IntervalPlcpLOF Gauge32, prtDs3IntervalPlcpRAI Gauge32, prtDs3IntervalPlcpBIP Gauge32, prtDs3IntervalPlcpFEBE Gauge32, prtDs3IntervalBPV Gauge32, prtDs3IntervalLCE Gauge32, prtDs3IntervalStatus OCTET STRING } prtDs3IntervalNumber OBJECT-TYPE SYNTAX Integer32 (1..96) MAX-ACCESS read-only STATUS current DESCRIPTION "A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid)." ::= { prtDs3IntervalEntry 1 } prtDs3IntervalLOS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of LOS seconds , encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals." ::= { prtDs3IntervalEntry 2 } prtDs3IntervalOOF OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of OOF seconds, encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals." ::= { prtDs3IntervalEntry 3 } prtDs3IntervalLOC OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of LOC seconds, encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals." ::= { prtDs3IntervalEntry 4 } prtDs3IntervalAIS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of AIS seconds, encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals." ::= { prtDs3IntervalEntry 5 } prtDs3IntervalRDI OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of RDI seconds, encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals." ::= { prtDs3IntervalEntry 6 } prtDs3IntervalUAS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of UAS, encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals." ::= { prtDs3IntervalEntry 7 } prtDs3IntervalBIP OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of BIP errors, encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals." ::= { prtDs3IntervalEntry 8 } prtDs3IntervalFEBE OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of FEBE errors, encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals." ::= { prtDs3IntervalEntry 9 } prtDs3IntervalSLM OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of SLM seconds, encountered by an E3 interface in one of the previous 96, individual 15 minute, intervals." ::= { prtDs3IntervalEntry 10 } prtDs3IntervalSES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of SES encountered by a E3 interface in one of the previous 96, individual 15 minute, intervals." ::= { prtDs3IntervalEntry 11 } prtDs3IntervalES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION " The number of Errored Seconds, encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals." ::= { prtDs3IntervalEntry 12 } prtDs3IntervalBitParity OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Bit Parity Error counter. Relevant to T3 only." ::= { prtDs3IntervalEntry 13 } prtDs3IntervalPlcpLOF OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of LOF seconds, encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals. This counter is relevant for plcpInternal(5) or plcpExternal(6) configuration If frame types only." ::= { prtDs3IntervalEntry 14 } prtDs3IntervalPlcpRAI OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Receiving Yellow/Remote Alarm Indication. This counter is relevant for PLCP (external/internal) frame types only." ::= { prtDs3IntervalEntry 15 } prtDs3IntervalPlcpBIP OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION " The counter associated with the number of BIP errors, encountered by a DS3 interface in the current 15 minute interval. This counter is relevant for PLCP (external/internal) frame types only." ::= { prtDs3IntervalEntry 16 } prtDs3IntervalPlcpFEBE OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION " The counter associated with the number of FEBE errors, encountered by a DS3 interface in the current 15 minute interval. This counter is relevant for PLCP (external/internal) frame types only." ::= { prtDs3IntervalEntry 17 } prtDs3IntervalBPV OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of BPVs (Bi-Polar Violations) , encountered by a DS3 interface in the specified 15 minute interval. This object is relevant only for Electrical Line of Fomi-E3/T3." ::= { prtDs3IntervalEntry 18 } prtDs3IntervalLCE OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of LCE (Link Code Errors) encountered by a DS3 interface in the specified 15 minute interval. This object is relevant only for Optical Links of Fomi-E3/T3." ::= { prtDs3IntervalEntry 19 } prtDs3IntervalStatus OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) MAX-ACCESS read-only STATUS current DESCRIPTION "The statuses of the current interval: 0 - Valid. 1 - redundantLinkSwitch - the link has been switched by a redundancy mechanism. 2 - discontinuity - module was partialy out. 4 - notValid - module is out." ::= { prtDs3IntervalEntry 20 } -- the DS3 Total table prtDs3TotalTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtDs3TotalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " A list of Total entries." ::= { prtDs3PerfHistory 4 } prtDs3TotalEntry OBJECT-TYPE SYNTAX PrtDs3TotalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry of Total table." INDEX { ifIndex } ::= { prtDs3TotalTable 1 } PrtDs3TotalEntry ::= SEQUENCE { prtDs3TotalUAS Gauge32, prtDs3TotalBPV Gauge32, prtDs3TotalLCE Gauge32 } prtDs3TotalUAS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of UASs (Unavailable Seconds) , encountered by a DS3 interface in the previous 96 intervals. Invalid 15 minute intervals count as 0." ::= { prtDs3TotalEntry 6 } prtDs3TotalBPV OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of BPVs (Bi-Polar Violations) , encountered by a DS3 interface in the previous 96 intervals. Invalid 15 minute intervals count as 0." ::= { prtDs3TotalEntry 17 } prtDs3TotalLCE OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of LCE (Link Code Errors) encountered by a DS3 interface in the previous 96 intervals. Invalid 15 minute intervals count as 0." ::= { prtDs3TotalEntry 18 } END -- -- file :v:\doc\rdv\mib\ver485\atm\radima.txt -- RAD-IMA-MIB DEFINITIONS ::= BEGIN --Title: RAD-IMA MIB -- -- Copyright 1998 RAD Data Communications, Ltd. -- All Rights Reserved. -- IMPORTS -- OBJECT-TYPE FROM RFC-1212 -- radWan FROM RAD-GEN-MIB; -- RAD-IMA MIB --Title: RAD's IMA INTERFACE MIB --Version: 1.0 --Date: 15.09.98 --By: Ilana Schvetz --File: radima.mib -- Last Update 20.01.02 by Ilana Schvetz radAtmIma OBJECT IDENTIFIER ::= {radAtm 5} imaPrimaryClk OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), link1(2), link2(3), link3(4), link4(5), automatic(6) } MAX-ACCESS read-write STATUS current DESCRIPTION "Clock source to be transmitted to the user side, where user module is in 'External' clock source." ::= { radAtmIma 1 } -- An extension to the Link Table imaXLinkTable OBJECT-TYPE SYNTAX SEQUENCE OF ImaXLinkEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The IMA Link Status and Configuration table. This table contains additional objects for the link table." ::= { radAtmIma 2 } imaXLinkEntry OBJECT-TYPE SYNTAX ImaXLinkEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the IMA Link table." -- AUGMENTS { imaLinkTable } INDEX { imaLinkIfIndex } ::= { imaXLinkTable 1 } ImaXLinkEntry ::= SEQUENCE { imaLinkDirection INTEGER, imaLinkItcLBClkSrc INTEGER } imaLinkDirection OBJECT-TYPE SYNTAX INTEGER { rx(1), tx(2), both(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "the Link direction." -- DEFAULT { both } ::= { imaXLinkEntry 1 } imaLinkItcLBClkSrc OBJECT-TYPE SYNTAX INTEGER { link1(1), link2(2), link3(3), link4(4), internal (5), external (6), automatic(7), loopback (8) } MAX-ACCESS read-write STATUS current DESCRIPTION "Clock source for the current Tx-line." ::= { imaXLinkEntry 2 } -- An extension to the Group Table imaXGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF ImaXGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The IMA group Status and Configuration table. This table contains additional objects for the Group table." ::= { radAtmIma 3 } imaXGroupEntry OBJECT-TYPE SYNTAX ImaXGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the IMA Group table." -- AUGMENTS { imaGroupTable } INDEX { imaGroupIndex } ::= { imaXGroupTable 1 } ImaXGroupEntry ::= SEQUENCE { imaGroupVersion INTEGER, imaGroupCtcTxClkSrc INTEGER, imaGroupCtcTxClkSrcPort Integer32 } imaGroupVersion OBJECT-TYPE SYNTAX INTEGER { ver10(1), ver11(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "IMA Version." ::= { imaXGroupEntry 1 } imaGroupCtcTxClkSrc OBJECT-TYPE SYNTAX INTEGER { link1 (1), link2 (2), link3 (3), link4 (4), internal (5), external (6), automatic (7), loopback (8), notApplicable(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "The source of the transmitted, common, Clock Source. Applicable if imaGroupNeTxClkMode=ctc(1). Automatic - Dynamic source, taken from the currently reference link. Internal - taken from the Internal clock on card. Loopback - Looped back from one of the ports. In this case a specific port should be selected for imaGroupCtcTxClkSrcPort parameter. Link N - Clock will be looped from one of the links." ::= { imaXGroupEntry 2 } imaGroupCtcTxClkSrcPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter is valid only when imaGroupCtcTxClkSrc=loopback. The value may be any port identifier." ::= { imaXGroupEntry 3 } -- IMA Traps --NOTIFICATIONS atmImaGroupStatusChangeTrap NOTIFICATION-TYPE OBJECTS { imaGroupFailureStatus } STATUS current DESCRIPTION "This trap indicates IMA Group status change." ::= { radSysAtmEvents 80 } END -- -- file :v:\doc\rdv\mib\ver485\radhdlc.txt -- RAD-HDLC-MIB DEFINITIONS ::= BEGIN --Title: RAD-HDLC MIB -- -- Copyright 1998 RAD Data Communications, Ltd. -- All Rights Reserved. --Title: RAD's HDLC MIB --Version: 1.0 --Date: 15.09.98 --By: Ilana Schvetz --File: radhdlc.mib -- -- Last Update: 17-Jan-02 By Ilana Schvetz hdlcMibObjects OBJECT IDENTIFIER ::= {diverseIfWanGen 5} hdlcTable OBJECT-TYPE SYNTAX SEQUENCE OF HdlcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The HDLC configuration table." ::= { hdlcMibObjects 1 } hdlcEntry OBJECT-TYPE SYNTAX HdlcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in the RAD HDLC Table." INDEX { ifIndex } ::= { hdlcTable 1 } HdlcEntry ::= SEQUENCE { hdlcProtocol INTEGER, hdlcRateResolution INTEGER, hdlcTxClockSource INTEGER, hdlcTerminalMode INTEGER, hdlcLoopbackState INTEGER, hdlcTxClockPolarity INTEGER, hdlcFlowControl INTEGER, hdlcLineRate Integer32, hdlcRxClockMode INTEGER, hdlcLOF Gauge32, hdlcRxClockPolarity INTEGER } hdlcProtocol OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), v35(2), x21(3), rs530(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The HDLC protocol type V35 - HDLC encapsulated over V35 X21 - HDLC encapsulated over X21 RS530 - HDLC encapsulated over RS530" ::= { hdlcEntry 1 } hdlcRateResolution OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), nx56Kbps(2), nx64Kbps(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The baud rate of the internal clock." ::= { hdlcEntry 2 } hdlcTxClockSource OBJECT-TYPE SYNTAX INTEGER { internal(1), external(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The baud rate of the internal clock." ::= { hdlcEntry 3 } hdlcTerminalMode OBJECT-TYPE SYNTAX INTEGER { dce(1), dte(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "." ::= { hdlcEntry 4 } hdlcLoopbackState OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), internal(2), external(3), disable(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "internal - All data coming from the network port is looped back external - All data comming from the line is looped back." ::= { hdlcEntry 5 } hdlcTxClockPolarity OBJECT-TYPE SYNTAX INTEGER { normal (1), inverse(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "normal - The transmitted data is sampled at the middle of bit time inverse - The transmitted data is sampled at the end of the bit time (high data rate/long cable)." ::= { hdlcEntry 6 } hdlcFlowControl OBJECT-TYPE SYNTAX INTEGER { disable(1), enable (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable the CTS/RTS flow control signals." ::= { hdlcEntry 7 } hdlcLineRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The rate values for HDLC are n*56/64Kbps, where 1<=n<=32, 64, 128 and the following values: 1544, 3088, 6176. The rate values for HSSI is nMbps, where 1<=n<=52." ::= { hdlcEntry 8 } hdlcRxClockMode OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), internal (2), external (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "." ::= { hdlcEntry 9 } hdlcLOF OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of seconds the port is in Loss Of Frame state." ::= { hdlcEntry 10 } hdlcRxClockPolarity OBJECT-TYPE SYNTAX INTEGER { normal (1), inverse(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "normal - The received data is sampled at the middle of bit time inverse - The received data is sampled at the end of the bit time (high data rate/long cable)." ::= { hdlcEntry 11 } hdlcPerformance OBJECT IDENTIFIER ::= {hdlcMibObjects 2} hdlcCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF HdlcCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The HDLC Current table." ::= { hdlcPerformance 1 } hdlcCurrentEntry OBJECT-TYPE SYNTAX HdlcCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the HDLC Current table." INDEX { hdlcCurrentIfIndex } ::= { hdlcCurrentTable 1 } HdlcCurrentEntry ::= SEQUENCE { hdlcCurrentIfIndex Integer32, hdlcCurrentStatus OCTET STRING, hdlcCurrentLOF Gauge32, hdlcCurrentInFrames Gauge32, hdlcCurrentInErrors Gauge32, hdlcCurrentOutFrames Gauge32 } hdlcCurrentIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the HDLC interface. It may be ifIndex." ::= { hdlcCurrentEntry 1 } hdlcCurrentStatus OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) MAX-ACCESS read-only STATUS current DESCRIPTION "The statuses of the current interval: 0 - Valid. 1 - redundantLinkSwitch - the link has been switched by a redundancy mechanism. 2 - discontinuity - module was partialy out. 4 - notValid - module is out." ::= { hdlcCurrentEntry 2 } hdlcCurrentLOF OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of seconds the port is in Loss Of Frame state, encountered by the HDLC interface in the current 15 minute interval." ::= { hdlcCurrentEntry 3 } hdlcCurrentInFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received frames, encountered by the HDLC interface in the current 15 minute interval." ::= { hdlcCurrentEntry 4 } hdlcCurrentInErrors OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Errored received frames, encountered by the HDLC interface in the current 15 minute interval." ::= { hdlcCurrentEntry 5 } hdlcCurrentOutFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted frames, encountered by the HDLC interface in the current 15 minute interval." ::= { hdlcCurrentEntry 6 } --Interval Table hdlcIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF HdlcIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The HDLC Interval table." ::= { hdlcPerformance 2 } hdlcIntervalEntry OBJECT-TYPE SYNTAX HdlcIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the HDLC Interval table." INDEX { hdlcIntervalIfIndex, hdlcIntervalNumber } ::= { hdlcIntervalTable 1 } HdlcIntervalEntry ::= SEQUENCE { hdlcIntervalIfIndex Integer32, hdlcIntervalNumber Integer32, hdlcIntervalStatus OCTET STRING, hdlcIntervalLOF Gauge32, hdlcIntervalInFrames Gauge32, hdlcIntervalInErrors Gauge32, hdlcIntervalOutFrames Gauge32 } hdlcIntervalIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the HDLC interface. It may be ifIndex." ::= { hdlcIntervalEntry 1 } hdlcIntervalNumber OBJECT-TYPE SYNTAX Integer32 (1..96) MAX-ACCESS read-only STATUS current DESCRIPTION "A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals exist)." ::= { hdlcIntervalEntry 2 } hdlcIntervalStatus OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) MAX-ACCESS read-only STATUS current DESCRIPTION "The statuses of the current interval: 0 - Valid. 1 - redundantLinkSwitch - the link has been switched by a redundancy mechanism. 2 - discontinuity - module was partialy out. 4 - notValid - module is out." ::= { hdlcIntervalEntry 3 } hdlcIntervalLOF OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of seconds the port is in Loss Of Frame state, encountered by an HDLC interface in one of the previous 96, individual 15 minute, intervals." ::= { hdlcIntervalEntry 4 } hdlcIntervalInFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received frames, encountered by the HDLC interface in one of the previous 96, individual 15 minute, intervals." ::= { hdlcIntervalEntry 5 } hdlcIntervalInErrors OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Errored received frames, encountered by the HDLC interface in one of the previous 96, individual 15 minute, intervals." ::= { hdlcIntervalEntry 6 } hdlcIntervalOutFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted frames, encountered by the HDLC interface in one of the previous 96, individual 15 minute, intervals." ::= { hdlcIntervalEntry 7 } -- -- file :v:\doc\rdv\mib\Before~1\sigmon.txt -- --Version: 1.0 --Date: 2.02.99 --By: Ilana Schvetz --File: sigmon.txt -- --Last Update: Ilana Schvetz 19.12.99 radAtmSignalingMonitor OBJECT IDENTIFIER ::= {radAtm 6 } smSVCOperState OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The SVC monitoring operational state." -- DEFVAL { disable } ::= { radAtmSignalingMonitor 1 } smSVCAdminStatus OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The SVC monitoring status." -- DEFVAL { disable } ::= { radAtmSignalingMonitor 2 } smILMIMode OBJECT-TYPE SYNTAX INTEGER { disable (1), keepAliveOnly (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The ILMI operational Mode." -- DEFVAL { disable } ::= { radAtmSignalingMonitor 3 } smILMIStatus OBJECT-TYPE SYNTAX INTEGER { down (1), up (2), disable (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "ILMI protocol status (VCC 0,16)." ::= { radAtmSignalingMonitor 4 } smUNIVersion OBJECT-TYPE SYNTAX INTEGER { uni3-0(1), uni3-1(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The UNI version that is used by both sides." -- DEFVAL { UNI3_1 } ::= { radAtmSignalingMonitor 5 } smPolicing OBJECT-TYPE SYNTAX INTEGER { none(1), police(2), monitoring(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The type of the police action performed on the cells transmitted from the user side to the network side." -- DEFVAL { none } ::= { radAtmSignalingMonitor 6 } smSAALStatus OBJECT-TYPE SYNTAX INTEGER { down (1), up (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Signaling data link (VCC 0,5) status." ::= { radAtmSignalingMonitor 7 } -- SM Counters smOpenedSesssions OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of SVC sessions currently opened." ::= { radAtmSignalingMonitor 8 } smUserRejectedSessions OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of sessions that the user side rejected to open." ::= { radAtmSignalingMonitor 9 } smNetworkRejectedSessions OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of sessions that the Network side rejected." ::= { radAtmSignalingMonitor 10 } smHostRejectedSessions OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of sessions that the device rejected to open." ::= { radAtmSignalingMonitor 11 } smVclILMISessionVpi OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "ILMI Keep alive session VPI channel. Default: 0. (VCI=16, fixed)." ::= { radAtmSignalingMonitor 12 } -- -- file :v:\doc\rdv\mib\ver475\atm\sub_rtr.txt -- -- -- file :sub_rtr.txt -- --RTR-MIB -- --Last update: 31-Dec-2001 --By: Yig'al Hachmon --radRouter OBJECT IDENTIFIER ::= { rad 11 } RAD Router -- ************************************************ -- Interfaces Group -- Link Layer (layer 2) Configuration MIB -- ************************************************ -- The following MIB group is used by the Management/Configuration -- station to configure the device interfaces, -- physicals as well as virtuals. -- Each entry in the rtrDynamicIfConfigTable should have one of -- the extended rtType. -- It will also have a corresponding entry in the standard iftable. -- The implementation uses these inputs to build the interface -- layer of the device. The output is reflected in the -- ifTable and ifStackTable which are implementation dependent. rtrInterfaces OBJECT IDENTIFIER ::= { radRouter 1 } RtrIfConfigTYPE ::= INTEGER -- STATUS current -- DESCRIPTION -- "This type defines what type of sub-layer is used -- in each entr of rtrDynamicIfConfigTable. -- It should contain values from IANAifType -- type for standard sub-layer, and values (starting from 999 -- decimal) for private sub-layers. -- The values of the ifType field in ifTable should be taken -- from IANAifType only." { other(1), ethernetLan(6), -- From IANAifType iso88023Csmacd(7), tokenRingLan(9), fddi(15), basicISDN(20), primaryISDN(21), propPointToPoint(22), -- rndWAN slip(28), ppp(23), -- From IANAifType frameRelay(32), rs232(33), atm(37), x25ple(40), v35(45), fastEther(62), -- Fast Ethernet (100BaseT) fastEtherFX(69), -- Fast Ethernet (100BaseFX) virtualNet(500), cod(1001), -- Rad/Rnd private backUp(1002), dialUp(1004), b1isdn(1010), b2isdn(1011), ipBcst(1020), ipPtp(1021), ipxRaw(1022), ipxEtType(1023), ipxLlcSap(1024), ipxLlcSnap(1025), ipxPtp(1026), brgUnder(1027), wanDriver(1060), ethernetDriver(1061), tokenRingDriver(1062), fddiDriver (1064), -- RAD private FDDI driver virtualLan(1080), unknown(1100) } rtrConfigIfTable OBJECT-TYPE SYNTAX SEQUENCE OF RtrConfigIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of configured interfaces." ::= { rtrInterfaces 1 } rtrConfigIfEntry OBJECT-TYPE SYNTAX RtrConfigIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry defines a configured interface." INDEX { rtrConfigIfIndex } ::= { rtrConfigIfTable 1 } RtrConfigIfEntry ::= SEQUENCE { rtrConfigIfIndex InterfaceIndex, rtrConfigIfType RtrIfConfigTYPE, rtrConfigIfName DisplayString, rtrConfigIfStatus RowStatus } rtrConfigIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This variable uniquely identifies the interface. It is used as a cross reference in other system tables" ::= { rtrConfigIfEntry 1 } rtrConfigIfType OBJECT-TYPE SYNTAX RtrIfConfigTYPE MAX-ACCESS read-create STATUS current DESCRIPTION "This variable identifies the type of the specific entry in the rtrDynamicIfConfigTable. This field is writable only at creation time (i.e., when value of status is underCreation)." ::= { rtrConfigIfEntry 2 } rtrConfigIfName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "This variable provides a logical name to a specific entry in rtrConfigIfTable. It is also used in identifying the Driver interfaces." ::= { rtrConfigIfEntry 3 } rtrConfigIfStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The status of the ConfigEntry. The choices are those defined in SNMPv2-TC. Only: active, createAndWait, and destroy will be used. active - The conceptual row is available for use by the managed device. createAndWait - A new instance of a conceptual row is desired, but not to have it available for use by the managed device. destroy - Delete all instances associated with an existing conceptual row." ::= { rtrConfigIfEntry 4 } -- **************** Interfaces Groups End ******************* -- **************** IP Groups ****************** -- IP Group -- ************************************************ -- IP Interface Configuration MIB -- ************************************************ ipSpec OBJECT IDENTIFIER ::= { radRouter 2 } rtrIpAddrTable OBJECT-TYPE SYNTAX SEQUENCE OF RtrIpAddrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is parralel to MIB II IpAddrTable, and is used to add/delete entries to/from that table. In addition it contains private objects." ::= { ipSpec 1 } rtrIpAddrEntry OBJECT-TYPE SYNTAX RtrIpAddrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The addressing information for one of this entity's IP addresses." INDEX {rtrIpAdEntAddr} ::= { rtrIpAddrTable 1 } RtrIpAddrEntry ::= SEQUENCE { rtrIpAdEntAddr IpAddress, rtrIpAdEntIfIndex Integer32, rtrIpAdEntNetMask IpAddress, rtrIpAdEntForwardIpBroadcast INTEGER, rtrIpAdEntBackupAddr IpAddress, rtrIpAdEntStatus RowStatus } rtrIpAdEntAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The IP address to which this entry's addressing information pertains." ::= { rtrIpAddrEntry 1 } rtrIpAdEntIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The index value which uniquely identifies the interface to which this entry is applicable. The interface identified by a particular value of this index is the same interface as identified by the same value of ifIndex." ::= { rtrIpAddrEntry 2 } rtrIpAdEntNetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "The subnet mask associated with the IP address of this entry. The value of the mask is an IP address with all the network bits set to 1 and all the hosts bits set to 0." ::= { rtrIpAddrEntry 3 } rtrIpAdEntForwardIpBroadcast OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-create STATUS current DESCRIPTION " This variable controls forwarding of IP (sub)net-directed broadcasts destined for an attached sub(net). " DEFVAL { enable } ::= { rtrIpAddrEntry 4 } rtrIpAdEntBackupAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION " " ::= { rtrIpAddrEntry 5 } rtrIpAdEntStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION " The Status variable is used to create and destroy a Ip Addresses." ::= { rtrIpAddrEntry 6 } icmpSpec OBJECT IDENTIFIER ::= { ipSpec 2 } rtrIcmpGenErrMsgEnable OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable controlls the ability to generate ICMP error messages" DEFVAL { enable } ::= { icmpSpec 1 } rtrIcmpRdTable OBJECT-TYPE SYNTAX SEQUENCE OF RtrIcmpRdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains ICMP Router Discovery parameters configurated per IP interface." ::= {icmpSpec 2} rtrIcmpRdEntry OBJECT-TYPE SYNTAX RtrIcmpRdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ICMP parameters configurated for IP interface." INDEX {rtrIcmpRdIpAddr} ::= {rtrIcmpRdTable 1} RtrIcmpRdEntry ::= SEQUENCE { rtrIcmpRdIpAddr IpAddress, rtrIcmpRdIpAdvertAddr IpAddress, rtrIcmpRdMaxAdvertInterval Integer32, rtrIcmpRdMinAdvertInterval Integer32, rtrIcmpRdAdvertLifetime Integer32, rtrIcmpRdAdvertise INTEGER, rtrIcmpRdPreferenceLevel Integer32, rtrIcmpRdEntStatus Integer32 } rtrIcmpRdIpAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The IP address to which this entry's information pertains." ::= {rtrIcmpRdEntry 1} rtrIcmpRdIpAdvertAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION " The IP destination address to be used for multicast Router Advertisements sent from the interface. The only permissible values are the all-systems multicast address, 224.0.0.1, or the limited-broadcast address, 255.255.255.255." -- DEFVAL {224.0.0.1} ::= {rtrIcmpRdEntry 2} rtrIcmpRdMaxAdvertInterval OBJECT-TYPE SYNTAX Integer32 (4..1800) MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum time allowed between sending multicast Router Advertisements from the interface, in seconds. Must be no less than 4 seconds and no greater than 1800 seconds." DEFVAL {600} ::= {rtrIcmpRdEntry 3} rtrIcmpRdMinAdvertInterval OBJECT-TYPE SYNTAX Integer32 (3..1800) MAX-ACCESS read-write STATUS current DESCRIPTION "The minimum time allowed between sending unsolicited multicast Router Advertisements from the interface, in seconds. Must be no less than 3 seconds and no greater than rtrIcmpRdMaxAdvertInterval. Default: 0.75 * rtrIcmpRdMaxAdvertInterval." ::= {rtrIcmpRdEntry 4} rtrIcmpRdAdvertLifetime OBJECT-TYPE SYNTAX Integer32 (4..9000) MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum length of time that the advertised addresses are to be considered as valid. Must be no less than rtrIcmpRdMaxAdvertInterval and no greater than 9000 seconds. Default: 3 * rtrIcmpRdMaxAdvertInterval." ::= {rtrIcmpRdEntry 5} rtrIcmpRdAdvertise OBJECT-TYPE SYNTAX INTEGER { enable (1), disable (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "A flag indicating whether or not the address is to be advertised." DEFVAL {enable} ::= {rtrIcmpRdEntry 6} rtrIcmpRdPreferenceLevel OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The preferability of the address as a default router address, relative to other router addresses on the same subnet." DEFVAL {0} ::= {rtrIcmpRdEntry 7} rtrIcmpRdEntStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Setting of any value to this object set values of all fields to the default values." ::= {rtrIcmpRdEntry 8} rip2Spec OBJECT IDENTIFIER ::= { ipSpec 3 } rtrRip2IfConfTable OBJECT-TYPE SYNTAX SEQUENCE OF RtrRip2IfConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is an extension of rip2IfConfTable (RFC 1724 ,RIP 2). It means that every time somebody creates/destroys a row in the rip2IfConfTable, the same row should be automatically created/destroyed in this table." ::= { rip2Spec 1 } rtrRip2IfConfEntry OBJECT-TYPE SYNTAX RtrRip2IfConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table rtrRip2IfConfTable." INDEX { rtrRip2IfConfAddress } ::= { rtrRip2IfConfTable 1 } RtrRip2IfConfEntry ::= SEQUENCE { rtrRip2IfConfAddress IpAddress, rtrRip2IfConfVirtualDis Integer32, rtrRip2IfConfAutoSend INTEGER } rtrRip2IfConfAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION " The IP Address of this system on the indicated subnet. " ::= { rtrRip2IfConfEntry 1 } rtrRip2IfConfVirtualDis OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This variable defines the virtual number of hops assigned to the interface specified by rtrIfIpAddrIndex. This enables fine-tuning of the RIP routing algorithm." DEFVAL { 1 } ::= { rtrRip2IfConfEntry 2 } rtrRip2IfConfAutoSend OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "When set to enable only the default route is sent through the interface. When set to disable, regular RIPs are sent." DEFVAL { disable } ::= { rtrRip2IfConfEntry 3 } arpSpec OBJECT IDENTIFIER ::= { ipSpec 4 } rtrArpDeleteTable OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this object to any not-null value has the effect of deleting all entries of the ARP table." ::= { arpSpec 1 } rtrArpInactiveTimeOut OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable defines the maximum time period (in second) that can pass between ARP requests concerning an entry in the ARP table. After this time period, the entry is deleted from the table." DEFVAL { 60000 } ::= { arpSpec 2 } rtrArpProxy OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "When ARP Proxy is enabled, the router can respond to ARP requests for nodes located on a different sub-net, provided they are it its network table. The router responds with its own MAC address. When ARP Proxy is disabled, the router responds only to ARP requests for its own IP addresses." DEFVAL { disable } ::= { arpSpec 3 } -- **************************************** -- NAT Network Address Translation -- ***************************************** rtrNat OBJECT IDENTIFIER ::= { ipSpec 5 } rtrNatIfConfTable OBJECT-TYPE SYNTAX SEQUENCE OF RtrNatIfConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of interfaces which require separate NAT configuration." ::= {rtrNat 1} rtrNatIfConfEntry OBJECT-TYPE SYNTAX RtrNatIfConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A single routing domain in a single subnet." INDEX { ifIndex, rtrNatIfVirtualAddress, rtrNatIfVirtualMask } ::= { rtrNatIfConfTable 1 } RtrNatIfConfEntry ::= SEQUENCE { rtrNatIfVirtualAddress IpAddress, rtrNatIfVirtualMask IpAddress, rtrNatIfConfStatus RowStatus, rtrNatIfRealAddress IpAddress, rtrNatIfRealMask IpAddress, rtrNatIfType INTEGER } rtrNatIfVirtualAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The IP Address of the virtual subnet to be translated by the 'NAT box' attached to this interface." ::= { rtrNatIfConfEntry 1 } rtrNatIfVirtualMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The subnet Mask of the virtual subnet. " ::= { rtrNatIfConfEntry 2 } rtrNatIfConfStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Writing 'destroy' has the effect of deleting this interface." ::= { rtrNatIfConfEntry 3 } rtrNatIfRealAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION " The IP Address of the real subnet which is used by 'NAT box' for translation." ::= { rtrNatIfConfEntry 4 } rtrNatIfRealMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION " The subnet Mask of the real subnet." ::= { rtrNatIfConfEntry 5 } rtrNatIfType OBJECT-TYPE SYNTAX INTEGER { static (1), dynamic (2), pat (3), transparent (4) } MAX-ACCESS read-create STATUS current DESCRIPTION "NAT type. static - Translate a specific virtual IP network to a specific real IP network. TCP, UDP and ICMP sessions originated both in real and virtual networks will be translated. dynamic - (Concurrent) Translate real IP network to larger or equal virtual IP network. TCP, UDP and ICMP sessions originated in virtual networks only can be translated and sessions originated in real networks will be rejected. A session that starts in the NAT system will be active until there will be no traffic for aging timeout period. pat - (Port Address Translation/ Single IP). Translate one real IP address to virtual IP network. TCP, UDP and ICMP sessions originated in virtual network only can be translated, sessions originated in real network will be rejected. A session that starts in the NAT system will be active until there will be no traffic for aging timeout period. transparent - In transparent mode all frames belonging to the defined IP network will be forwarded with no translation: virtual = real." ::= { rtrNatIfConfEntry 6 } -- ************************************* -- Port Address Translation -- ************************************* rtrPatTable OBJECT-TYPE SYNTAX SEQUENCE OF RtrPatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Port Address Translation (PAT - single IP NAT) configuration Table." ::= {rtrNat 2} rtrPatEntry OBJECT-TYPE SYNTAX RtrPatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry describe unique mapping between real IP address, range of ports and protocol, to local (virtual) IP address. Ports are used in the TCP (rfc793) to name the ends of logical connections which carry long term conversations. For the purpose of providing services to unknown callers, a service contact port is defined. " INDEX { rtrPatIdx } ::= { rtrPatTable 1 } RtrPatEntry ::= SEQUENCE { rtrPatIdx Integer32, rtrPatRealAddress IpAddress, rtrPatVirtualAddress IpAddress, rtrPatLowestPort Integer32, rtrPatHighestPort Integer32, rtrPatProtocol INTEGER, rtrPatStatus RowStatus } rtrPatIdx OBJECT-TYPE SYNTAX Integer32 (1..10) MAX-ACCESS read-only STATUS current DESCRIPTION "Running index for PAT table." ::= { rtrPatEntry 1 } rtrPatRealAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "The real IP Address used for translation " ::= { rtrPatEntry 2 } rtrPatVirtualAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "The virtual IP Address used for translation" ::= { rtrPatEntry 3 } rtrPatLowestPort OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-create STATUS current DESCRIPTION "Lowest Port number for this PAT entry " ::= { rtrPatEntry 4 } rtrPatHighestPort OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-create STATUS current DESCRIPTION "Highest Port number for this PAT entry " ::= { rtrPatEntry 5 } rtrPatProtocol OBJECT-TYPE SYNTAX INTEGER { tcp (6), udp (17) } MAX-ACCESS read-create STATUS current DESCRIPTION "Protocol selected. This Protocol and port range (lowest port - highest port) define the application (FTP, Telnet, SMTP etc.). Protocol enumaration numbers correspond to IP header 'protocol' field " ::= { rtrPatEntry 6 } rtrPatStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object enables creating and deleting entries of the table." ::= { rtrPatEntry 7 } -- ************************************************ -- FACS MIB -- ************************************************ rtrFACS OBJECT IDENTIFIER ::= { radRouter 5 } rtrFACSDefaultAction OBJECT-TYPE SYNTAX INTEGER { block(1), forward(2), blockAndReport(129) } MAX-ACCESS read-write STATUS current DESCRIPTION "Used to define the default action for the device, when no FACS statements applicable to a given frame are defined." -- DEFVAL { 1 } ::= { rtrFACS 1 } rtrFACSActTable OBJECT-TYPE SYNTAX SEQUENCE OF RtrFACSActEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of FACS action." ::= { rtrFACS 2 } rtrFACSActEntry OBJECT-TYPE SYNTAX RtrFACSActEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each rtrFACSActEntry consist of the following parameters" INDEX {rtrFACSActType, rtrFACSActIfIndex} ::= { rtrFACSActTable 1 } RtrFACSActEntry ::= SEQUENCE { rtrFACSActType INTEGER, rtrFACSActIfIndex Integer32, rtrFACSAction INTEGER, rtrFACSActiveDB INTEGER } rtrFACSActType OBJECT-TYPE SYNTAX INTEGER { tx(1), rx(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates on which FACS Table the FACS action will preform." ::= { rtrFACSActEntry 1 } rtrFACSActIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The interface to which this FACS entry is applicable." ::= { rtrFACSActEntry 2 } rtrFACSAction OBJECT-TYPE SYNTAX INTEGER { none(1), eraseIP(2), eraseDECnet(3), eraseIPX(4), eraseBrg(5), replaceIP(6), replaceIPX(8), replaceBrg(9), backupIP(10), backupIPX(12), backupBrg(13) } MAX-ACCESS read-write STATUS current DESCRIPTION "The management station that sends a SET request for one of these actions with indexes rtrFACSType and rtrFACSIfIndex defines the type and the interface Id for which all FACS statements are to be erased. If no interface or no type is specified, all FACS statements for a protocol are erased." -- DEFVAL { 1 } ::= { rtrFACSActEntry 3 } rtrFACSActiveDB OBJECT-TYPE SYNTAX INTEGER { active(1), temporary(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter will point on which Facs DataBase the SNMP agent read. The Active dataBase is Read Only. The user may change FACS statements in the temporary DataBase and then write it to the Active DB." ::= { rtrFACSActEntry 4} rtrFACSTable OBJECT-TYPE SYNTAX SEQUENCE OF RtrFACSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of FACS statment." ::= { rtrFACS 3 } rtrFACSEntry OBJECT-TYPE SYNTAX RtrFACSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each FACS statment consists of the following parameters" INDEX {rtrFACSIfIndex, rtrFACSProtocolType, rtrFACSType, rtrFACSIndex } ::= { rtrFACSTable 1 } RtrFACSEntry ::= SEQUENCE { rtrFACSIfIndex Integer32, rtrFACSProtocolType INTEGER, rtrFACSType INTEGER, rtrFACSIndex Integer32, rtrFACSSrcAdd OCTET STRING , rtrFACSSrcAddMask OCTET STRING, rtrFACSDesAdd OCTET STRING, rtrFACSDesAddMask OCTET STRING, rtrFACSOperation INTEGER, rtrFACSNetFiltering INTEGER, rtrFACSSocketNum Integer32, rtrFACSMask1Id Integer32, rtrFACSMask2Id Integer32, rtrFACSStatus INTEGER } rtrFACSIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The interface to which this FACS entry is applicable. For applications this variables is always 0." ::= { rtrFACSEntry 1 } rtrFACSProtocolType OBJECT-TYPE SYNTAX INTEGER{ ip(1), ipx(2), dec(3), bridge(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter define the protocol the Security Access Control is applicable." ::= { rtrFACSEntry 2 } rtrFACSType OBJECT-TYPE SYNTAX INTEGER { tx(1), rx(2), cod(3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The Mode of in which this FACS statement operates. For applications this variable is always rx(2)." ::= { rtrFACSEntry 3 } rtrFACSIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Index to the FACS Table. " ::= { rtrFACSEntry 4 } rtrFACSSrcAdd OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "The size of the octet string will be according to the protocol type defined in rtrFACSProtocolType." ::= { rtrFACSEntry 5 } rtrFACSSrcAddMask OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Source-address mask ." ::= { rtrFACSEntry 6 } rtrFACSDesAdd OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Destination-address The size of the octet string will be according to the protocol type define in rtrFACSProtocolType ." ::= { rtrFACSEntry 7 } rtrFACSDesAddMask OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Destination-address mask ." ::= { rtrFACSEntry 8 } rtrFACSOperation OBJECT-TYPE SYNTAX INTEGER { block(1), forward(2), permit(3), -- For Connect On demand Only deny(4), -- For Connect On demand Only blockAndReport(129) } MAX-ACCESS read-write STATUS current DESCRIPTION "... ." ::= { rtrFACSEntry 9 } rtrFACSNetFiltering OBJECT-TYPE SYNTAX INTEGER { none(1), l2multicast(2), --applicable for Bridge protocol arp(3), --applicable for ip protocol icmp(4), --applicable for ip protocol ip(5), --applicable for ip protocol udp(6), --applicable for ip protocol tcp(7), --applicable for ip protocol decnet(8), --applicable for decnet protocol ipx(9) --applicable for ipx protocol } MAX-ACCESS read-write STATUS current DESCRIPTION "... ." ::= { rtrFACSEntry 10 } rtrFACSSocketNum OBJECT-TYPE --applicable for ip,ipx protocol SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Port/socket number for different applications 0 is default meaning not applicable. none(1), ftp(21), telnet(23), smtp(25), tftp(69), snmp(161), snmpTrap(162), rip(520), sapIPX(1106), ripIPX(1107) " ::= { rtrFACSEntry 11} rtrFACSMask1Id OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Index into RND mask table FACS/COD Type) ." ::= { rtrFACSEntry 12} rtrFACSMask2Id OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Index into RND mask table FACS/COD according to the value of rtrFACSType ." ::= { rtrFACSEntry 13} rtrFACSStatus OBJECT-TYPE SYNTAX INTEGER { valid(1), createRequest(2), underCreation(3), invalid(4) -- logically deleted } MAX-ACCESS read-write STATUS current DESCRIPTION "The status of a table entry." ::= { rtrFACSEntry 14} rtrFACSFrameData OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "Data from the frame that violated a FACS Filter." ::= { rtrFACS 4 } -- **************** FACS Group Ends ******************* -- ************************************************ -- Bridge ports Configuration MIB -- ************************************************ -- rtrBridge OBJECT IDENTIFIER ::= { radRouter 7 } rtrBridgePortConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF RtrBridgePortConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of the bridge ports" ::= { rtrBridge 1 } rtrBridgePortConfigEntry OBJECT-TYPE SYNTAX RtrBridgePortConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry defines a bridge port " INDEX { rtrBridgePortCIndex } ::= { rtrBridgePortConfigTable 1 } RtrBridgePortConfigEntry ::= SEQUENCE { rtrBridgePortCIndex Integer32, rtrBridgePortCIf Integer32, rtrBridgePortCStatus RowStatus } rtrBridgePortCIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is the index of the bridge port. It is the same as 'dot1dBasePort' of the Bridge MIB." ::= {rtrBridgePortConfigEntry 1} rtrBridgePortCIf OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The config ifIndex the bridge port is sitting on. " ::= {rtrBridgePortConfigEntry 2} rtrBridgePortCStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The status of the RtrBridgePortConfigEntry. Creating and destroying the bridge port is done by this variable." ::= {rtrBridgePortConfigEntry 3} -- **************** Router Bridge Port Group Ends ******************* -- Traps rtrFACSViolation NOTIFICATION-TYPE OBJECTS { rtrFACSFrameData, rtrFACSProtocolType } STATUS current DESCRIPTION "The trap is sent for every violation of a FACS filter." ::= { radSysRtrEvents 1 } rtrSwDwnLoadTrap NOTIFICATION-TYPE OBJECTS { fileName } STATUS current DESCRIPTION "The trap is sent after the tftp download of the software and before the decompression and reset operations." ::= { radSysRtrEvents 2 } END -- -- file :v:\doc\rdv\mib\ver485\optimux2.txt -- OPTIMUX-MIB DEFINITIONS ::= BEGIN --Title: OPTIMUX MIB -- -- Copyright 1993 RAD Data Communications, Ltd. -- All Rights Reserved. -- It is RAD's intent to encourage the widespread use of -- this Specification in connection with the management of -- RAD products. RAD grants vendors, end-users, -- and other interested parties a non-exclusive license to -- use this Specification in connection with the management -- of RAD products. -- This Specification is supplied "as is," and RAD makes -- no warranty, either express or implied, as to the use, -- operation, condition, or performance of the Specification. --IMPORTS -- DisplayString FROM RFC1213-MIB -- enterprises FROM RFC1155-SMI -- OBJECT-TYPE FROM RFC-1212 -- TRAP-TYPE FROM RFC-1215 -- ifIndex, InterfaceIndex FROM IF-MIB -- dsx1LoopbackStatus FROM DS1-MIB -- dsx3LoopbackStatus FROM DS3-MIB; -- radWan, agnIndication FROM RAD-GEN-MIB; -- RAD-OPTIMUX MIB --Title: RAD's OPTIMUX PRODUCT MIB --Version: 2.0 --Date: 14/01/97 --By: Michele Hallak --File: optimux2.txt -- --rad OBJECT IDENTIFIER ::= { enterprises 164 } --radWan OBJECT IDENTIFIER ::= { rad 3 } rad WAN Tree --radGen OBJECT IDENTIFIER ::= { rad 6} General information --Last update: 17-July-2002 by Shlomo Shoham optimux OBJECT IDENTIFIER ::= { radWan 5 } -- One Optimux is sometimes connected to another optimux (or other device) -- via its link. Therefore, in some cases, the SNMP agent sitting on -- one device is responsible of the second (remote) -- device. This table supplies information for both -- devices, while the first is the local one and the second -- is the remote one. optMxConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF OptMxConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains parameters of configuration for each member of the couple of Optimux." ::= { optimux 1 } optMxConfigEntry OBJECT-TYPE SYNTAX OptMxConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Optimux Config table." INDEX { optIndex } ::= { optMxConfigTable 1 } OptMxConfigEntry ::= SEQUENCE { optIndex INTEGER, optHWVersion DisplayString, optSWVersion DisplayString, optPSPrimary INTEGER, optPSSecondary INTEGER, optLinkActive InterfaceIndex, optSelectLink INTEGER, optGrpPayLoadLoop INTEGER, optGrpClockSource INTEGER, optRedundancyStatus INTEGER, optRedundancyCnf INTEGER, optFarEndType INTEGER, optServiceChEnable INTEGER, --planned for Opt-4E1-C but not in use optMaskChAlr Integer32, optAisEnable INTEGER, optFarMng INTEGER, optClockDivision INTEGER, optDteLoopEnable INTEGER, optGrpClockSourcePrt Integer32, optIncomingAlarm INTEGER, optDefChannelSet INTEGER, optWaitToRestore Integer32, optEnforcedLink INTEGER } optIndex OBJECT-TYPE SYNTAX INTEGER {local(1), remote(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "optIndex = 1 is for local Optimux. optIndex = 2 is for remote Optimux." ::= { optMxConfigEntry 1 } optHWVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "HW Version of the device." ::= { optMxConfigEntry 2 } optSWVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "SW Version of the device." ::= { optMxConfigEntry 3 } optPSPrimary OBJECT-TYPE SYNTAX INTEGER { unknown(1), fault(3), active(4), none(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the primary Power Supply Unit." DEFVAL { active } ::= { optMxConfigEntry 4 } optPSSecondary OBJECT-TYPE SYNTAX INTEGER { unknown(1), fault(3), active(4), none(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the secondary Power Supply Unit." DEFVAL { none } ::= { optMxConfigEntry 5 } optLinkActive OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates which link is active. For Optimux-4 it may be: 5, 6 or 105, 106 For FOMi-E3/T3 it may be: 51, 61 or 151, 161. For Optimux-T3 it may be: 51 or 61." ::= { optMxConfigEntry 6 } optSelectLink OBJECT-TYPE SYNTAX INTEGER { autoredundancy(1), -- autoWoReturn(4), not in use for this version of Opt-4-C main(5), back(6) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used by Optimux 4E1/T1 and Optimux-T3. - For Optimux 4E1/T1: This MIB object enables the user to force the device to use specific link. autoredundancy= Main (Link 1) is the default link. When it will fail, the device will use Backup (Link 2). If Main recovers, it automatically returns to Main. autoWoReturn = Automatic Without Return. Main (Link 1) is the default link. When it will fail, the device will use Backup (Link 2). If Main recovers, it will NOT return to Main. It will continue using Backup. This option is supported only by LRS cards. main = Forces the device to start immediately use of Main (Link 1), no matter what is its state and stay there. No Redundancy. back = Forces the device to start immediately use of Backup (Link 2), no matter what is its state and stay there. No Redundancy. - For Optimux-T3: This MIB object is used to select which Link will be used as MAIN. Therefore: autoredundancy - not supported main = Link A is MAIN (=default). back = Link B is MAIN." DEFVAL { autoredundancy } ::= { optMxConfigEntry 7 } optGrpPayLoadLoop OBJECT-TYPE SYNTAX INTEGER { off(2), on(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Performs payload loop ( remote loop) to 4 E1 channels at once." DEFVAL { off } ::= { optMxConfigEntry 8 } optGrpClockSource OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), localInternal(2), localExternal(3), loopTiming(4), transparent(5) } MAX-ACCESS read-write STATUS current DESCRIPTION "For Optimux XL: If dsx3TransmitClockSource = localTiming(2), then the user can configure this field as: localInternal(2) = use the internal clock of the device localExternal(3) = use the external clock connected to the port dedicated to clock. For FomiE3/T3 this object is always applicable. localExternal(3) = station clock transparent(5) = the device takes the clock info from the data. For FomiE3/T3 with HSSI electrical interface, only the following are valid: localInternal(2) and transparent(5). For Optimux-T3 the applicable values are (2), (3), (4)." DEFVAL { notApplicable } ::= { optMxConfigEntry 9 } optRedundancyStatus OBJECT-TYPE SYNTAX INTEGER { available(2), notAvailable(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "If there are two modules 'links', then this field should be set to available(2). If there is only one module 'link', this field should be set to notAvailable(3)." DEFVAL { available } ::= { optMxConfigEntry 10 } optRedundancyCnf OBJECT-TYPE SYNTAX INTEGER { off(2), auto(3), manual(4), forcedBU(6) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used by Optimux-XL, FomiE3/T3 and Optimux-T3. For Optimux-XL: If optRedundancyStatus = notAvailable(3), then this field can be off(2) or forcedBU(6). - off(2) = forcedMain: forces the device to start immediately use of Main (Link 1), no matter what is its state and stay there - forcedBU(6) = forces the device to start immediately use of Backup (Link 2), no matter what is its state and stay there. This value is not supported by Optimux-T3. Else, user can configure this field as: auto(3) = switch back to main link when valid. manual(4) = don't switch back to main link = automatic w/o return. For FomiE3/T3 all values are applicable unconditioned. For Optimux-T3, values off(2), auto(3), manual(4) are applicable unconditioned." DEFVAL { auto } ::= { optMxConfigEntry 11 } optFarEndType OBJECT-TYPE SYNTAX INTEGER { unknown (1), optimux4Sa (2), optimux4Card(3), fomiE3T3Sa (4), fomiE3T3Card(5), optimuxXL16 (6), optimuxXLE1 (7), optimux4E1L (8), optimux4T1L (9), notApplicable(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Far-End type of product. This object is especially relevant for the local optimux. optimux4Sa (2), optimux4Card(3),optimux4E1L (8), optimux4T1L (9) - are relevant only for Optimux-4E1/T1 cards. notApplicable - for devices that don't have a far-end unit." ::= { optMxConfigEntry 12 } optServiceChEnable OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), disabled (2), enabled (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Service Channel Enable/Disable for each Optimux (local/remote). This object is applicable only for Optimux cards." ::= { optMxConfigEntry 13 } optMaskChAlr OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Mask Channel Alarm. This object is applicable only for Optimux cards. The value of this object is a sum of 2**n, where n is a bit assigned to a certain Channel. For Optimux-4: Bit0: CH1 ; Bit1: CH2 ; Bit2: CH3 ; Bit3: CH4 (Bit='1' means masked). Examples: - 15 : means that all Channels are masked. - 9 : means that Alarms of CH 1 and CH 4 are masked. For Optimux-T3: Bit0: CH1 ; Bit1: CH2 ; Bit2: CH3 ;.. Bit20: CH21 OR Bit27: CH28 (Bit='1' means masked)." ::= { optMxConfigEntry 14 } optAisEnable OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "AIS enable/disable. notApplicable - for devices that do not support this feature." ::= { optMxConfigEntry 15 } optFarMng OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used by Optimux-XL and FomiE3/T3. Is there possibility of Far-End Management (no/yes). This object is applicable only for the Local device. notApplicable - for Remote device and devices that do not support it. no - far-end device is NOT I-Type so it doesn't have a management link to its pair-device. yes - far-end device is I-Type so it has a management link to its pair-device." ::= { optMxConfigEntry 16 } optClockDivision OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), noDivision (2), half (3), quarter (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is applicable only for FomiE3/T3 having an HSSI Electrical interface. It gives the possibility of Clock Division, so that Clock Rate will be less than T3/E3. notApplicable - for a device that does not support it noDivision - Clock stays as is (Internal or Transparent) half - Clock will be half the original (divided by 2) quarter - Clock will be a quarter of the original (divided by 4)." ::= { optMxConfigEntry 17 } optDteLoopEnable OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "DTE Loop enable/disable (for example loop command requested by router). This object is applicable only for products having HSSI interface. notApplicable - for devices that do not support this feature." ::= { optMxConfigEntry 18 } optGrpClockSourcePrt OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object is applicable only for Optimux-T3, when optGrpClockSource=localExternal. It enables the user to select the Channel or Station Clock from which the Clock is received. Valid values: 0 = notApplicable 1..28 (= CH1..CH28). 73 = Station Clock. Only T1 Channels can be used as Clock Source." ::= { optMxConfigEntry 19 } optIncomingAlarm OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), off(2), on(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "State of the Incoming Alarm (On/Off), via Alarm Relay connector. This object is applicable only for Optimux-T3." ::= { optMxConfigEntry 20 } optDefChannelSet OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), t1(2), e1(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Default configuration for all Optimux Channels: T1 or E1. This object is applicable only for Optimux-T3." ::= { optMxConfigEntry 21 } optWaitToRestore OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter defines the time (sec) device has to wait in the redundant state until it goes back to the default Link." ::= { optMxConfigEntry 22 } optEnforcedLink OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), noEnforcement(2), main(5), backup(6) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter enables user to enforce a Link in spite of the redundancy mechanism. Selecting the noEnforcement(2) value cause return to the usual rules of the redundancy mechanism." ::= { optMxConfigEntry 23 } -- This table is for XL Optimux, Optimux-T3 and FOMi-E3/T3 SA optMxModuleTable OBJECT-TYPE SYNTAX SEQUENCE OF OptMxModuleEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table defines the type of the module enrolled in each slot." ::= { optimux 2 } optMxModuleEntry OBJECT-TYPE SYNTAX OptMxModuleEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Optimux Module table." INDEX { optMdIdx, optMdSltIdx } ::= { optMxModuleTable 1 } OptMxModuleEntry ::= SEQUENCE { optMdIdx INTEGER, optMdSltIdx Integer32, optMdType INTEGER, optMdHWVersion DisplayString, optMdModLed OCTET STRING, optMdWaveLength INTEGER, optMdTimingMode INTEGER } optMdIdx OBJECT-TYPE SYNTAX INTEGER {local(1), remote(2) } MAX-ACCESS read-only STATUS current DESCRIPTION " optMdIdx = 1 is for local Optimux. optMdIdx = 2 is for remote Optimux." ::= { optMxModuleEntry 1 } optMdSltIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "For Optimux XL: Slot A = 1, Slot B = 2, Slot C = 3, Slot D = 4, Slot Link = 5, Slot BU = 6 . For FomiE3/R3: Slot of Station Clock = 3, Slot of Electrical Link = 4, Slot of Optical Main Link = 5, Slot of Optical Backup Link = 6 . For Optimux-T3: Slot of Station Clock (internal card)= 3, Slot A = 5, Slot B = 6." ::= { optMxModuleEntry 2 } optMdType OBJECT-TYPE SYNTAX INTEGER { unknown(1), noModule(2), e3linkCX34(3), e3linkOPT1(4), t3linkOPT1(5), eth1Port(6), e1FourUTP(7), e1TwoPort(8), e1TwoUB(9), t1FourPort(10), t1TwoPort(11), e1FourRJ45(12), -- special for XL/16 e1FourBNC(13), -- special for XL/16 e1FourMiniBNC(14), sfLink(15), -- single fiber stationClk(16), -- for E1/E3 products only (not for XL/T1) hssi(17), stationClkT3(18), -- for FOMi-T3 and Optimux-T3 only t3linkCX45(19), -- for FOMi-T3 and Optimux-T3 only hs4(20), -- for HSM with 4 ports hs2(21), -- for HSM with 2 ports hs1(22), -- for HSM with 1 port hs1x8M(23), -- for HSM with 1 port and 8M fastEth(24), -- for fast ethernet with 1 port nX64(25), -- for N x 64 E1 module nX64AndUnbalanced2E1(26), -- N X 64 and unbalanced 2 E1 ports nX64AndBalanced2E1(27), -- N X 64 and balanced 2 E1 ports nX64T1(28), nX64T1AndUnbalanced2T1(29), -- N X 64 T1 and unbalanced 2 T1 ports nX64T1AndBalanced2T1(30) -- N X 64 T1 and balanced 2 T1 ports } MAX-ACCESS read-only STATUS current DESCRIPTION "Module Type and number of connectors." ::= { optMxModuleEntry 3 } optMdHWVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "HW Version of the module." ::= { optMxModuleEntry 4 } optMdModLed OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The meaning of each bit depends on the module type." ::= { optMxModuleEntry 5 } optMdWaveLength OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), nm850(2), nm1300(3), nm1300Laser(4), nm1550Laser(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Wave Length of T3/E3 Optical Links in [nm] and specification if Laser or not." ::= { optMxModuleEntry 6 } optMdTimingMode OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), internal(2), external(3), lbt(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The Module Timing mode." ::= { optMxModuleEntry 7 } -- This table is for Optimux T3 that can be in a ring optimuxRing OBJECT IDENTIFIER ::= {optimux 3} optFramerPortTable OBJECT-TYPE SYNTAX SEQUENCE OF OptFramerPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table defines the connection of every ch of the framer." ::= {optimuxRing 1} optFramerPortEntry OBJECT-TYPE SYNTAX OptFramerPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Optimux Framer port Connections table." INDEX { optFramerPortIdx } ::= { optFramerPortTable 1 } OptFramerPortEntry ::= SEQUENCE { optFramerPortIdx Integer32, optFramerPortConn Integer32, optFramerPortType INTEGER, optFramerPortFeIpAddr IpAddress } optFramerPortIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The channel of the Framer. Valid values:1..31." ::= { optFramerPortEntry 1 } optFramerPortConn OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter defines the Framer channel connection. The values will be as follows: Loop(1),Ch1(2),Ch2(3)....,Ch28(29)." ::= { optFramerPortEntry 2 } optFramerPortType OBJECT-TYPE SYNTAX INTEGER{ notApplicable (1), e1 (2), t1 (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter defines the Framer port (E1 or T1)." ::= { optFramerPortEntry 3 } optFramerPortFeIpAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The IP Address of the opposite optimux in the ring,which this channel connected to." ::= { optFramerPortEntry 4 } optFramerConnChanges OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The number of changes in Framer connection table that occured since last time there was a reset to this parameter" ::= {optimuxRing 2} optRing OBJECT-TYPE SYNTAX INTEGER { noRing(2), ring(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates if this optimux can be part of a ring." ::= {optimuxRing 3 } optRingNeTable OBJECT-TYPE SYNTAX SEQUENCE OF OptRingNeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table defines which optimuxes are in the ring and the IP Address of each one." ::= { optimuxRing 4} optRingNeEntry OBJECT-TYPE SYNTAX OptRingNeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Optimux Ring Connections table." INDEX { optRingNeIdx } ::= { optRingNeTable 1 } OptRingNeEntry ::= SEQUENCE { optRingNeIdx Integer32, optRingNeIpAddr IpAddress } optRingNeIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the optimux, starting with next optimux to the current optimux. Valid values:1..28. The index is according to the order of optimux connections in the ring. Example: 1=next optimux to the current, in the ring 2=next optimux in the ring, after the one having index=1 etc.. Last index will be the current optimux, that close the ring. " ::= { optRingNeEntry 1 } optRingNeIpAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The IP Address of each optimux in the ring, according to optRingNeIdx." ::= { optRingNeEntry 2 } -- Traps --NOTIFICATIONS optimuxEvents OBJECT-IDENTITY STATUS current DESCRIPTION "The events for Optimux." ::= { optimux 0 } optMxConfigChange NOTIFICATION-TYPE OBJECTS {optIndex, agnLed } STATUS current DESCRIPTION "The trap is sent every time there is a change in the state of one of the PS.." ::= { optimuxEvents 1 } optMxAgentFault NOTIFICATION-TYPE OBJECTS {agnIndication, agnLed } STATUS current DESCRIPTION "The trap is sent every time there is a change in the agnIndication variable." ::= { optimuxEvents 2 } optLineStatusChange NOTIFICATION-TYPE OBJECTS { dsx1LineStatus, dsx1LineStatusLastChange } STATUS current DESCRIPTION "optLineStatusChange trap is sent when the value of an instance dsx1LineStatus changes. It can be utilized by an NMS to trigger polls. When the line status change results from a higher level line status change (i.e. ds3), then no traps for the ds1 are sent." ::= { optimuxEvents 3 } optSlotChange NOTIFICATION-TYPE OBJECTS { optMdIdx, optMdSltIdx } STATUS current DESCRIPTION "This trap alerts the console if there is module enrollement/de-enrollement " ::= { optimuxEvents 4 } optLoopbackStatusChange NOTIFICATION-TYPE OBJECTS { ifIndex, dsx1LoopbackStatus, dsx3LoopbackStatus } STATUS current DESCRIPTION "This trap alerts the console if there is changes in the loopback status of some of the line." ::= { optimuxEvents 5 } optXlLineStatusChange NOTIFICATION-TYPE OBJECTS { ifIndex, optMdModLed, dsx1LineStatus, dsx3LineStatus } STATUS current DESCRIPTION "optXlLineStatusChange trap is sent when the value of an instance dsx1LineStatus changes. It can be utilized by an NMS to trigger polls." ::= { optimuxEvents 6 } -- -- file :v:\doc\rdv\mib\ver485\webrnger.txt -- --Version: 1.0 --Date: 26.04.98 --By: Ilana Schvetz --File: webranger.txt -- --Last Update: Liora Gafni 12-Aug-2002 --radRouter OBJECT IDENTIFIER ::= { rad 11 } --rtrBridge OBJECT IDENTIFIER ::= { radRouter 7 } webranger OBJECT IDENTIFIER ::= { rtrBridge 2 } wrSysConfig OBJECT IDENTIFIER ::= { webranger 1 } wrBraodcastCtrlCmd OBJECT-TYPE SYNTAX INTEGER { block (1), forward (2), blockLinkPropagation (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter is a command to the webranger CPU. It enables blocking or forwarding broadcast frames, which may cause a trigger to a connection. block (1) - blocks the broadcast frames. forward (2) - forwards the broadcast frames. blockLinkPropagation (3) - blocks the broadcast frames to the links, tx to the LAN. " ::= { wrSysConfig 1 } wrFrSelfLearningMode OBJECT-TYPE SYNTAX INTEGER { off (1), on (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter enables the webranger to learn the DLCi's configuration and maintanance protocol. off - will get the configuration by setting it. on - disables configuration and start self learnning." ::= { wrSysConfig 2 } wrIpRouterInfo OBJECT IDENTIFIER ::= { webranger 2 } wrConfigIpDhcp OBJECT IDENTIFIER ::= { wrIpRouterInfo 1 } wrDhcpAction OBJECT-TYPE SYNTAX INTEGER { disable (2), enable (3) -- Enable DHCP Server only } MAX-ACCESS read-write STATUS current DESCRIPTION "Activating (disable/enable) DHCP server operation. Since DHCP Server and DHCP Relay cannot reside in same device, DHCP Relay may be enabled (per interface), only if server action is disabled" ::= { wrConfigIpDhcp 1 } wrDhcpTable OBJECT-TYPE SYNTAX SEQUENCE OF WrDhcpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of DHCP entries. The number of entries is up to DHCP current entries, according to the WEBRANger model." ::= { wrConfigIpDhcp 2 } wrDhcpEntry OBJECT-TYPE SYNTAX WrDhcpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "DHCP parameters per entry of the DHCP table." INDEX { wrDhcpLowIpAddress } ::= { wrDhcpTable 1 } WrDhcpEntry ::= SEQUENCE { wrDhcpLowIpAddress IpAddress, wrDhcpHighIpAddress IpAddress, wrDhcpIpMaskAddress IpAddress, wrDhcpDefaultGateway IpAddress, wrDhcpPrimaryDNS IpAddress, wrDhcpSecondaryDNS IpAddress, wrDhcpInterface INTEGER, wrDhcpRowStatus RowStatus, wrDhcpIpAddressLeaseTime Integer32, wrDhcpPoolName SnmpAdminString } wrDhcpLowIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "DHCP Low Ip Address." ::= { wrDhcpEntry 1 } wrDhcpHighIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "DHCP High Ip Address." ::= { wrDhcpEntry 2 } wrDhcpIpMaskAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "IP mask Address." ::= { wrDhcpEntry 3 } wrDhcpDefaultGateway OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "Default Gateway's IP Address." ::= { wrDhcpEntry 4 } wrDhcpPrimaryDNS OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "Primary DNS." ::= { wrDhcpEntry 5 } wrDhcpSecondaryDNS OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "Secondary DNS." ::= { wrDhcpEntry 6 } wrDhcpInterface OBJECT-TYPE SYNTAX INTEGER { all (1), lan1 (2), lan2(3), anyLan(4), wan (5) } MAX-ACCESS read-create STATUS current DESCRIPTION "The IP addresse allocation is done according to the interface type from which the DHCP request arrives." ::= { wrDhcpEntry 7 } wrDhcpRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute allows to create/delete a row in this table. For creating a row, the NMS should set wrDhcpRowStatus.id = active(1). For destroying a row, the NMS should set: wrDhcpStatus.id = destroy(6). Only rows with status active(1) are relevant. The only possible supported RowStatus vaules are active (1) and destroy (6)." ::= { wrDhcpEntry 8 } wrDhcpIpAddressLeaseTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION " Allocated IP Address lease time in minutes, 0xFFFFFFFF (2**32-1) for infinity " ::= { wrDhcpEntry 9 } wrDhcpPoolName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (1..10)) MAX-ACCESS read-create STATUS current DESCRIPTION "DHCP pool name - string with max length of 10 characters" ::= { wrDhcpEntry 10 } -- DHCP (Dynamic Host Configuration Protocol) Pool Allocation Table dhcpPoolAllocTable OBJECT-TYPE SYNTAX SEQUENCE OF DhcpPoolAllocEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of DHCP Pool Allocation entries. Each entry (row) consist of a single IP Address belonging to DHCP pool whose lowest IP address is dhcpPoolAllocLowIpAddress. This IP address may be offered for leasing, or may already be leased (in use) by Host it's MacAddress is dhcpPoolAllocMacAddress. Time left for leasing period is indicated by dhcpPoolAllocTimeLeft. All posible statuses of IP address are indicated and controlled by dhcpPoolAllocFlags" ::= { wrConfigIpDhcp 3 } dhcpPoolAllocEntry OBJECT-TYPE SYNTAX DhcpPoolAllocEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "DHCP Pool Allocation parameters per entry of the DHCP Pool Allocation table." INDEX {dhcpPoolAllocLowIpAddress, dhcpPoolAllocLeasingIpAddress} ::= { dhcpPoolAllocTable 1 } DhcpPoolAllocEntry ::= SEQUENCE { dhcpPoolAllocLowIpAddress IpAddress, dhcpPoolAllocLeasingIpAddress IpAddress, dhcpPoolAllocMacAddress MacAddress, dhcpPoolAllocTimeLeft Integer32, dhcpPoolAllocFlags INTEGER, dhcpPoolAllocFreeCmd INTEGER } dhcpPoolAllocLowIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Lowest IP address of this pool, value eqaul to wrDhcpLowIpAddress for the pool." ::= { dhcpPoolAllocEntry 1 } dhcpPoolAllocLeasingIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Single IP Address belonging to dhcp pool whose Lowest Ip Address is dhcpPoolAllocLowIpAddress. This IP address may be offered for leasing or may be leased by Host its MacAddress is dhcpPoolAllocMacAddress. All posible statuses of IP address are indicated by dhcpPoolAllocFlags " ::= { dhcpPoolAllocEntry 2 } dhcpPoolAllocMacAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "MAC Address to which the IP address has been leased " ::= { dhcpPoolAllocEntry 3 } dhcpPoolAllocTimeLeft OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "IP address leasing time left in seconds " ::= { dhcpPoolAllocEntry 4 } dhcpPoolAllocFlags OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), free (2), inUse (3), offered (4), forbidden (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "These flags indicates status of each IP address. User may change value to free, via dhcpPoolAllocFreeCmd " ::= { dhcpPoolAllocEntry 5 } dhcpPoolAllocFreeCmd OBJECT-TYPE SYNTAX INTEGER { off (2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to On (3), will enforce the agent to Free this entry. The Agent will change the value of this MIB object to off(2) automatically, after performing the command. Setting this object to off(2), will do nothing" ::= { dhcpPoolAllocEntry 6 } --DHCP Relay Table dhcpRelayTable OBJECT-TYPE SYNTAX SEQUENCE OF DhcpRelayEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of DHCP relay entries." ::= { wrConfigIpDhcp 4 } dhcpRelayEntry OBJECT-TYPE SYNTAX DhcpRelayEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "DHCP Relay parameters per entry of the DHCP relay table." INDEX { ifIndex } ::= { dhcpRelayTable 1 } DhcpRelayEntry ::= SEQUENCE { dhcpRelayAction INTEGER, dhcpRelayServerIpAddress IpAddress, dhcpRelayMaxHop Integer32 } dhcpRelayAction OBJECT-TYPE SYNTAX INTEGER { disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to enable (3), will enable DHCP Relay action for this interface (Only if DHCP Server is disabled for device - wrDhcpAction=disable). dhcpRelayServerIpAddressaddress should not be 0.0.0.0 when enable is set" ::= { dhcpRelayEntry 1 } dhcpRelayServerIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "DHCP Server IP Address." ::= { dhcpRelayEntry 2 } dhcpRelayMaxHop OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Maximum number of hops till DHCP Server. upper limit is 16 hops" DEFVAL {16} ::= { dhcpRelayEntry 3 } wrDhcpPort OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), all (2), outOfBand (3), lan1 (4), lan2 (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter defines the port that DHCP flow will be actiavted." ::= { wrConfigIpDhcp 5} --DHCP Client Table dhcpClientTable OBJECT-TYPE SYNTAX SEQUENCE OF DhcpClientEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of DHCP client entries." ::= { wrConfigIpDhcp 6 } dhcpClientEntry OBJECT-TYPE SYNTAX DhcpClientEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "DHCP Client parameters per entry of the DHCP Client table." INDEX { ifIndex } ::= { dhcpClientTable 1 } DhcpClientEntry ::= SEQUENCE { dhcpClientAction INTEGER, dhcpClientServerIpAddress IpAddress, dhcpClientLeaseExpirationTime Integer32, dhcpClientStatus DisplayString } dhcpClientAction OBJECT-TYPE SYNTAX INTEGER { disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter default value is enable(3). Setting this attribute to disable (2), will disable DHCP Client action for this interface. This parameter can be changed to disable (2) only (it cannot be changed from disable to enable)." ::= { dhcpClientEntry 1 } dhcpClientServerIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "DHCP Server IP Address." ::= { dhcpClientEntry 2 } dhcpClientLeaseExpirationTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter holds the time (in minutes) left until lease expiration." ::= { dhcpClientEntry 3 } dhcpClientStatus OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This parametr displays the DHCP status." ::= { dhcpClientEntry 4 } wrConfigIpxRouterInfo OBJECT IDENTIFIER ::= { webranger 3 } wrAutoLearnLanIpxNets OBJECT-TYPE SYNTAX INTEGER { disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Activating (disable/enable) the auto-learn operation." ::= { wrConfigIpxRouterInfo 1 } wrLanIpxNetTable OBJECT-TYPE SYNTAX SEQUENCE OF WrLanIpxNetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Lan IPX nets Table." ::= { wrConfigIpxRouterInfo 2 } wrLanIpxNetEntry OBJECT-TYPE SYNTAX WrLanIpxNetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "IPX Nets per frame type & LAN port. The table entries will be created by the agent" INDEX { wrLanifIndex, wrLanIpxFrameType } ::= { wrLanIpxNetTable 1 } WrLanIpxNetEntry ::= SEQUENCE { wrLanifIndex Integer32, wrLanIpxFrameType INTEGER, wrIpxNetAddress IpAddress } wrLanifIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "LAN port ifIndex." ::= { wrLanIpxNetEntry 1 } wrLanIpxFrameType OBJECT-TYPE SYNTAX INTEGER{ t8023 (1), ethernet (2), t8022(3), snap (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Frame Type" ::= { wrLanIpxNetEntry 2 } wrIpxNetAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Net address per Frame Type & LAN port." ::= { wrLanIpxNetEntry 3 } wrDialInIpxNet OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Net address through a link." ::= { wrConfigIpxRouterInfo 3 } -- The RIP/SAP Interface Configuration Table. ripSapIfConfTable OBJECT-TYPE SYNTAX SEQUENCE OF RipSapIfConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of Interfaces which require separate configuration in RIP/SAP." ::= { wrConfigIpxRouterInfo 4 } ripSapIfConfEntry OBJECT-TYPE SYNTAX RipSapIfConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A Single Routing Domain in a single Subnet." INDEX { ripSapIfConfIfIndex } ::= { ripSapIfConfTable 1 } RipSapIfConfEntry ::= SEQUENCE { ripSapIfConfIfIndex Integer32, ripSapIfConfMode INTEGER, ripSapIfConfStatus RowStatus } ripSapIfConfIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The interface ifIndex." ::= { ripSapIfConfEntry 1 } ripSapIfConfMode OBJECT-TYPE SYNTAX INTEGER { off(1), on (2) } MAX-ACCESS read-create STATUS current DESCRIPTION "The ifIndex RIP/SAP mode." ::= { ripSapIfConfEntry 2 } ripSapIfConfStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute allows to create/delete a row in this table. For creating a row, the NMS should set ripSapIfConfStatus.id1 = active(1). For destroying a row, the NMS should set: ripSapIfConfStatus.id1 = destroy(6). Only rows with status active(1) are relevant. The only possible supported RowStatus vaules are active (1) and destroy (6)." ::= { ripSapIfConfEntry 3 } wrInterface OBJECT IDENTIFIER ::= { webranger 4 } wrIpAddressTable OBJECT-TYPE SYNTAX SEQUENCE OF WrIpAddressEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Link IP addresses Table." ::= { wrInterface 1 } wrIpAddressEntry OBJECT-TYPE SYNTAX WrIpAddressEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Ip Address per Link" INDEX { wrIpIfIndex } ::= { wrIpAddressTable 1 } WrIpAddressEntry ::= SEQUENCE { wrIpIfIndex Integer32, wrIpAddress IpAddress, wrIpMask IpAddress, wrIpRowStatus RowStatus } wrIpIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Port interface index." ::= { wrIpAddressEntry 1 } wrIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "Link IP Address." ::= { wrIpAddressEntry 2 } wrIpMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "Link IP mask Address." ::= { wrIpAddressEntry 3 } wrIpRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute allows to create/delete a row in this table. For creating a row, the NMS should set wrIpRowStatus.id1 = active(1). For destroying a row, the NMS should set: wrIpRowStatus.id1 = destroy(6). Only rows with status active(1) are relevant. The only possible supported RowStatus vaules are active (1) and destroy (6)." ::= { wrIpAddressEntry 4 } wrSpoofingTable OBJECT-TYPE SYNTAX SEQUENCE OF WrSpoofingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Spoofing Table." ::= { wrInterface 2 } wrSpoofingEntry OBJECT-TYPE SYNTAX WrSpoofingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Spoofing per Link" INDEX { wrSpoofingIfIndex } ::= { wrSpoofingTable 1 } WrSpoofingEntry ::= SEQUENCE { wrSpoofingIfIndex Integer32, wrSpoofingAction Integer32, wrSpoofingAgingStation Integer32, wrSpoofingRowStatus RowStatus } wrSpoofingIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Port interface index." ::= { wrSpoofingEntry 1 } wrSpoofingAction OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Spoofing action is applied by bit code: enable : bit 0 set (disable: bit 0 is 0) keepAlive : bit 1 ... : bit 2 and so on. For the above example, to set spoofing to keepAlive action, the object's value will be 3 = [ 2**0 + 2**1 ] Only the Remote WEBRANger will accept this object ! ------- " ::= { wrSpoofingEntry 2 } wrSpoofingAgingStation OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION " Aging time of stations list, in min. The agent 'translates' the time entered in minutes, to 10 min. resolution, as follows: 1..10 min - 10 min 11..20 min - 20 min and so on... 0 is not a valid value. Only the Remote WEBRANger will accept this object ! ---------------- " ::= { wrSpoofingEntry 3 } wrSpoofingRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute allows to create/delete a row in this table. For creating a row, the NMS should set wrSpoofingRowStatus.id1 = active(1). For destroying a row, the NMS should set: wrSpoofingRowStatus.id1 = destroy(6). Only rows with status active(1) are relevant. The only possible supported RowStatus vaules are active (1) and destroy (6)." ::= { wrSpoofingEntry 4 } wrLanIfTable OBJECT-TYPE SYNTAX SEQUENCE OF WrLanIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Link IP addresses Table." ::= { wrInterface 3 } wrLanIfEntry OBJECT-TYPE SYNTAX WrLanIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Ip Address per Link" INDEX { wrLanIfIndex } ::= { wrLanIfTable 1 } WrLanIfEntry ::= SEQUENCE { wrLanIfIndex Integer32, wrLanBridgeRouterMode INTEGER, wrLanIfState INTEGER, wrLanIfRdnTimeout Integer32 } wrLanIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Port interface index." ::= { wrLanIfEntry 1 } wrLanBridgeRouterMode OBJECT-TYPE SYNTAX INTEGER { unknown (1), bridge (2), ipRouter (3), ipxRouter (4), ipAndIpxRouter (5), bRouter (6), ipBrouter (7), ipxBrouter (8), ipAndIpxBrouter (9), bridgeAndStp (10) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter indicates whether the link is Bridge or Router and specifies the Router's type." ::= { wrLanIfEntry 2 } wrLanIfState OBJECT-TYPE SYNTAX INTEGER { disable(2), enable (3), redundancy(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The LAN is disabled or enabled. For LAN 2 it can be also 'redundancy'." ::= { wrLanIfEntry 3 } wrLanIfRdnTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "LAN Redundancy Timeout in seconds. Applicable when wrLanIfState=redundancy." ::= { wrLanIfEntry 4 } wrSyncCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF WrSyncCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Configuration table for Async interface." ::= { wrInterface 4 } wrSyncCnfgEntry OBJECT-TYPE SYNTAX WrSyncCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Configuration table" INDEX { wrSyncIfIndex } ::= { wrSyncCnfgTable 1 } WrSyncCnfgEntry ::= SEQUENCE { wrSyncIfIndex Integer32, wrSyncClkMode INTEGER, wrSyncClkRate INTEGER } wrSyncIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Sync interface index." ::= { wrSyncCnfgEntry 1 } wrSyncClkMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), manual (2), program (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Clock Mode." ::= { wrSyncCnfgEntry 2 } wrSyncClkRate OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), r16 (2), r32 (3), r48 (4), r64 (5), r96 (6), r128 (7), r256 (8), r768 (9) } MAX-ACCESS read-write STATUS current DESCRIPTION "Clock Rate in. Rate can be changed if Clock Mode is Program only." ::= { wrSyncCnfgEntry 3 } wrFrCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF WrFrCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Configuration table for Fr parameters that do not exist in RFC2115." ::= { wrInterface 5 } wrFrCnfgEntry OBJECT-TYPE SYNTAX WrFrCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Configuration entry for Fr parameters that do not exist in RFC2115." INDEX { ifIndex } ::= { wrFrCnfgTable 1 } WrFrCnfgEntry ::= SEQUENCE { wrFrDlciLearningMode INTEGER, wrFrCllmMessages INTEGER } wrFrDlciLearningMode OBJECT-TYPE SYNTAX INTEGER { off (2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter enables the webranger to learn the DLCi's configuration and maintanance protocol for the current interface. off - the WR will read the user's configuration for this interface. on - the WR will begin self learning of the current interface's maintanance protocol and DLCIs." ::= { wrFrCnfgEntry 1 } wrFrCllmMessages OBJECT-TYPE SYNTAX INTEGER { disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter enables/disables the Webranger to Tx/Rx CLLM (Consolidated Link Layer Management) messages via DLCI 1023. The CLLM messages are link layer control messages. They can be used for example in cases of congestion. The CLLM message contains a code for cause of congestion and list of all DLCIs that should act to reduce data transmission." ::= { wrFrCnfgEntry 2 } -- -- file :v:\doc\rdv\mib\ver485\iprouter.txt -- --Version: 1.0 --Date: 31.01.99 --By: Ilana Schvetz --File: ipRouter.txt -- --Last Update: Ilana Schvetz 09/01/02 --radRouter OBJECT IDENTIFIER ::= { rad 11 } --rtrBridge OBJECT IDENTIFIER ::= { radRouter 7 } ipRouter OBJECT IDENTIFIER ::= { rtrBridge 3 } rtrIfIpTable OBJECT-TYPE SYNTAX SEQUENCE OF RtrIfIpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Router interfaces table." ::= { ipRouter 1 } rtrIfIpEntry OBJECT-TYPE SYNTAX RtrIfIpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table rtrIfIpTable." INDEX { rtrIfIp } ::= { rtrIfIpTable 1 } RtrIfIpEntry ::= SEQUENCE { rtrIfIp IpAddress, rtrIfRowStatus RowStatus, rtrIfIpMask IpAddress, rtrIfIndex Integer32, rtrIfMng INTEGER, rtrIfVlanId VlanIndex } rtrIfIp OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "IP Address." ::= { rtrIfIpEntry 1 } rtrIfRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "." ::= { rtrIfIpEntry 2 } rtrIfIpMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "IP mask Address." ::= { rtrIfIpEntry 3 } rtrIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The ifIndex connection, on which the IP is determined." ::= { rtrIfIpEntry 4 } rtrIfMng OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } MAX-ACCESS read-create STATUS current DESCRIPTION "An IP interface might be determined as a management connection (under the product limitations)." ::= { rtrIfIpEntry 5 } rtrIfVlanId OBJECT-TYPE SYNTAX VlanIndex MAX-ACCESS read-create STATUS current DESCRIPTION "The VLAN ID assigned to Tagged frames transmitted from this port. The value inserted should be a defined VLAN." ::= { rtrIfIpEntry 6 } -- Brouter Table brtrIfTable OBJECT-TYPE SYNTAX SEQUENCE OF BrtrIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "LAN interface table." ::= { ipRouter 2 } brtrIfEntry OBJECT-TYPE SYNTAX BrtrIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The entries of this table will be created by agent." INDEX { brtrIfIndex } ::= { brtrIfTable 1 } BrtrIfEntry ::= SEQUENCE { brtrIfIndex Integer32, brtrIfMode INTEGER, brtrIfMaxFrameSize Integer32 } brtrIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the interface (LAN or ATM)." ::= { brtrIfEntry 1 } brtrIfMode OBJECT-TYPE SYNTAX INTEGER { bridge (1), router (2), brouter (3), off (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Connection Mode." ::= { brtrIfEntry 2 } brtrIfMaxFrameSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Frame Max Size." ::= { brtrIfEntry 3 } rtrArpAgingTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "ARP Aging Time. Applicable for a Router Mode and for a Brouter Mode." ::= { ipRouter 3 } -- Brouter LAN If table brtrLanIfTable OBJECT-TYPE SYNTAX SEQUENCE OF BrtrLanIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "LAN interface table." ::= { ipRouter 4 } brtrLanIfEntry OBJECT-TYPE SYNTAX BrtrLanIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The entries of this table will be created by agent ." INDEX { brtrLanIfIndex } ::= { brtrLanIfTable 1 } BrtrLanIfEntry ::= SEQUENCE { brtrLanIfIndex Integer32, brtrLanIpAddress IpAddress, brtrLanIpMask IpAddress, brtrLanMaxRateEnable INTEGER, brtrLanMaxRate Integer32, brtrLanMng INTEGER, brtrLanDefaultRouter IpAddress } brtrLanIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the LAN entity (physical interface)." ::= { brtrLanIfEntry 1 } brtrLanIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Host IP address. Applicable for bridge mode connection only." ::= { brtrLanIfEntry 2 } brtrLanIpMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Host IP Mask. Applicable for bridge mode connection only." ::= { brtrLanIfEntry 3 } brtrLanMaxRateEnable OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter determines the HW ability of the LAN card according to HW." ::= { brtrLanIfEntry 4 } brtrLanMaxRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Max Rate." ::= { brtrLanIfEntry 5 } brtrLanMng OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "An IP interface might be determined as a management connection (under the product limitations)." ::= { brtrLanIfEntry 6 } brtrLanDefaultRouter OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Default Router's (Gateway's) IP Address. For each LAN interface there may be a different Default Router." ::= { brtrLanIfEntry 7 } rtrIsdnIfTable OBJECT-TYPE SYNTAX SEQUENCE OF RtrIsdnIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains ISDN parameters that do not appear in the standard MIBs." ::= { ipRouter 5 } rtrIsdnIfEntry OBJECT-TYPE SYNTAX RtrIsdnIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries for ISDN parameters that do not appear in the standard MIBs." AUGMENTS { isdnSignalingEntry } -- INDEX { isdnSignalingIndex } ::= { rtrIsdnIfTable 1 } RtrIsdnIfEntry ::= SEQUENCE { rtrIsdnIfMinNumBchans Integer32, rtrIsdnIfMaxNumBchans Integer32 } rtrIsdnIfMinNumBchans OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Minimum number of B channels that the ISDN Dialer of the router will use for Dialing out. This parameter will be used for the BOD (Bandwidth On Demand) feature. Dial up on B channels is according to the need of bandwidth for router data transfer. Voice calls have a higher priority than router data. In case of few time slots the voice calls will cause disconnection of data channels up to the limit of minimum number of B channels." ::= { rtrIsdnIfEntry 1 } rtrIsdnIfMaxNumBchans OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Maximum number of B channels that the ISDN Dialer of the router will use for Dialing out. This parameter will be used for the BOD (Bandwidth On Demand) feature. Dial up on B channels is according to the need of bandwidth for router data transfer. Voice calls have a higher priority than router data. No more than MAX B channels will be used by the ISDN dialer." ::= {rtrIsdnIfEntry 2 } rtrLcrTable OBJECT-TYPE SYNTAX SEQUENCE OF RtrLcrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Least Cost Routing Table. The user will be able to set a prefix for an outgoing number that arrives with a predefined prefix in order to redirect the number for the LCR process to be achieved." ::= { ipRouter 6 } rtrLcrEntry OBJECT-TYPE SYNTAX RtrLcrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Least Cost Routing Entry." INDEX { ifIndex, rtrLcrOutIfIndex } ::= { rtrLcrTable 1 } RtrLcrEntry ::= SEQUENCE { rtrLcrOutIfIndex InterfaceIndex, rtrLcrRowStatus RowStatus, rtrLcrInPrefix DisplayString, rtrLcrOutPrefix DisplayString } rtrLcrOutIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "The outgoing interface Number of the current route. The incoming interface number is the value of ifIndex." ::= { rtrLcrEntry 1 } rtrLcrRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Row Status for adding/destroying rows." ::= { rtrLcrEntry 2 } rtrLcrInPrefix OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "This prefix is part of the called number existing in the incoming packet." ::= {rtrLcrEntry 3 } rtrLcrOutPrefix OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "This prefix will be inserted into the outgoing packet." ::= {rtrLcrEntry 4 } --radRouter OBJECT IDENTIFIER ::= { rad 11 } multicastGen OBJECT IDENTIFIER ::= { radRouter 8 } -- General Multicast Parameters multicastMode OBJECT-TYPE SYNTAX INTEGER { disable (2), wanToLan (3), wanToLanIgmp (4), lanToWan (5), bidirectional(6), transparent(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "According to this mode the packets will be forwarded. If disable (2) is selected, there will be no multicast." ::= { multicastGen 1 } -- -- file :v:\doc\rdv\mib\ver480\v51.txt -- --Title: RAD's WAN V5.1 Interface MIB --By: Smadar Tauber --Date : 03.11.1998 --Last Update: 17/01/02 --By: Smadar --File: v:\doc\rdv\mib\ver480\v51.txt --IMPORTS -- enterprises FROM RFC1155-SMI -- DisplayString FROM RFC1213-MIB -- IpAddress FROM RFC1155-SMI -- OCTET STRING FROM RFC1213-MIB -- OBJECT-TYPE FROM RFC1212; --wanGen OBJECT IDENTIFIER ::= {radWan 1} --diverseIfWanGen OBJECT IDENTIFIER ::= {wanGen 6} (see mpmx.txt) v51If OBJECT IDENTIFIER ::= {diverseIfWanGen 6} v51General OBJECT IDENTIFIER ::= {v51If 1} v51Variant OBJECT IDENTIFIER ::= {v51If 2} v51Ml OBJECT IDENTIFIER ::= {v51If 3} v51AccessPort OBJECT IDENTIFIER ::= {v51If 4} --NPL parameters (for most of the manual parameters see TDSoft MIB) npl OBJECT IDENTIFIER ::= {v51General 1} nplMode OBJECT-TYPE SYNTAX INTEGER { auto (2), manual(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "NPL Mode." ::= { npl 1 } nplCountry OBJECT-TYPE SYNTAX INTEGER { none (1), france (2), germany (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "National Protocol Country." ::= { npl 2 } nplVoicePathDuration OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Maximum time of a voice path, in msec." ::= { npl 3 } --NPL Pulse table nplPulseTable OBJECT-TYPE SYNTAX SEQUENCE OF NplPulseEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NPL Pulse table. This table is written directly to the agent." ::= { npl 4 } nplPulseEntry OBJECT-TYPE SYNTAX NplPulseEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table nplPulseTable." INDEX {nplPulseType} ::= { nplPulseTable 1} NplPulseEntry ::= SEQUENCE { nplPulseType INTEGER, nplPulseValid INTEGER, nplPulseDurationType Integer32, nplPulseOnTime Integer32, nplPulseOffTime Integer32 } nplPulseType OBJECT-TYPE SYNTAX INTEGER { meteringPulse1 (1), meteringPulse2 (2), initRinging1 (3), initRinging2 (4), normalBattery (237), noBattery (250), reducedBattery (251), reversePolarity(254), normalPolarity (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Pulse Type" ::= {nplPulseEntry 1} nplPulseValid OBJECT-TYPE SYNTAX INTEGER { notValid (2), valid (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Validity of the Pulse Type." ::= {nplPulseEntry 2} nplPulseDurationType OBJECT-TYPE SYNTAX Integer32 (0..31) MAX-ACCESS read-write STATUS current DESCRIPTION "Pulse Duration Type. - If meteringPulse1 and meteringPulse2 are both 'valid', the value of this object must be different for them. - If initRinging1 and initRinging2 are both 'valid', the value of this object must be different for them." ::= {nplPulseEntry 3} nplPulseOnTime OBJECT-TYPE SYNTAX Integer32 (0..990) MAX-ACCESS read-write STATUS current DESCRIPTION "How much time the pulse is ON, in msec. 0 is a valid value only when nplPulseValid=notValid." ::= {nplPulseEntry 4} nplPulseOffTime OBJECT-TYPE SYNTAX Integer32 (0..990) MAX-ACCESS read-write STATUS current DESCRIPTION "How much time the pulse is OFF, in msec." ::= {nplPulseEntry 5} --Variant tables -- --Variant table - Configuration and Status at Variant Level -- --Only ONE variant exists per link in the Temporary Configuration v51VarTable OBJECT-TYPE SYNTAX SEQUENCE OF V51VarEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= { v51Variant 1} v51VarEntry OBJECT-TYPE SYNTAX V51VarEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table v51VarTable." INDEX {v51VarCnfgIdx, v51VarSltIdx, v51VarPrtIdx, v51VarIdx } ::= { v51VarTable 1} V51VarEntry ::= SEQUENCE { v51VarCnfgIdx Integer32, v51VarSltIdx INTEGER, v51VarPrtIdx Integer32, v51VarIdx Integer32, v51VarPstnCch INTEGER, v51VarIsdnSTypeCch INTEGER, v51VarDescription DisplayString, v51VarStatus INTEGER } v51VarCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg being accessed. 255 = TmpCnfg. 1 = Current Cnfg. Write is allowed only to TmpCnfg." ::= {v51VarEntry 1} v51VarSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Slot Index" ::= {v51VarEntry 2} v51VarPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number of the ML having V5 interface. Valid values: exPrt1 (1)..exPrt4 (4), inPrt1(101)..inPrt4(104)." ::= {v51VarEntry 3} v51VarIdx OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Variant Id. Valid values: - for Current Cnfg: 0..127 - for Tmp Cnfg: 255 only." ::= {v51VarEntry 4} v51VarPstnCch OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), ts15 (2), ts16 (3), ts31 (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates which TS will be used for PSTN C channel." ::= {v51VarEntry 5} v51VarIsdnSTypeCch OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), ts15 (2), ts16 (3), ts31 (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates which TS will be used for S-Type C channel." ::= {v51VarEntry 6} v51VarDescription OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This object describes the Variant." ::= {v51VarEntry 7} v51VarStatus OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), notActive (2), active (3), activeReq (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object reports the status of an existing Variant of a link. notActive - the variant exists on this link but is not active active - the variant exists on this link AND is active activeReq - the variant exists on this link and it was requested to be active, but the request is still in negotiation (it can be either accepted as active, or not). This object is not applicable for v51VarCnfgIdx=255=TmpCnfg." ::= {v51VarEntry 8} --Variant Configuration and Status table - TS Level v51VarCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF V51VarCfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= { v51Variant 2} v51VarCfgEntry OBJECT-TYPE SYNTAX V51VarCfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table v51VarCfgTable." INDEX {v51VarCfgIndex, v51VarCfgSltIdx, v51VarCfgPrtIdx, v51VarCfgIdx, v51VarCfgTsIdx} ::= { v51VarCfgTable 1} V51VarCfgEntry ::= SEQUENCE { v51VarCfgIndex Integer32, v51VarCfgSltIdx INTEGER, v51VarCfgPrtIdx Integer32, v51VarCfgIdx Integer32, v51VarCfgTsIdx Integer32, v51VarCfgTsType INTEGER, v51VarCfgPrtId Integer32, v51VarCfgEfL3Addr Integer32, v51VarCfgFTypeCch INTEGER, v51VarCfgPTypeCch INTEGER, v51VarCfgConSlt INTEGER, v51VarCfgConPrt Integer32, v51VarCfgIoState INTEGER, v51VarCfgBlock INTEGER, v51VarCfgExtDch INTEGER, v51VarCfgExtDchSlot INTEGER, v51VarCfgExtDchPort Integer32, v51VarCfgExtDchTs Integer32, v51VarCfgExtDchCmpr INTEGER, v51VarCfgExtDchRate INTEGER, v51VarCfgExtDchStartBit Integer32 } v51VarCfgIndex OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg being accessed. 255 = TmpCnfg. 1 = Current Cnfg. " ::= {v51VarCfgEntry 1} v51VarCfgSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Slot Index" ::= {v51VarCfgEntry 2} v51VarCfgPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number of the ML having V5 interface. Valid values: exPrt1 (1)..exPrt4 (4), inPrt1(101)..inPrt4(104)" ::= {v51VarCfgEntry 3} v51VarCfgIdx OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Variant Id. Valid values: - for Current Cnfg: 0..127 - for Tmp Cnfg: 255 only." ::= {v51VarCfgEntry 4} v51VarCfgTsIdx OBJECT-TYPE SYNTAX Integer32 (1..31) MAX-ACCESS read-only STATUS current DESCRIPTION "Time Slot index." ::= {v51VarCfgEntry 5} v51VarCfgTsType OBJECT-TYPE SYNTAX INTEGER { nc (1), pstn (2), isdnB1 (3), isdnB2 (4), cChannel (5), permanentB1 (6), permanentB2 (7), semiPermanentB1 (8), semiPermanentB2 (9) } MAX-ACCESS read-write STATUS current DESCRIPTION "Time Slot Type." ::= {v51VarCfgEntry 6} v51VarCfgPrtId OBJECT-TYPE SYNTAX Integer32 (0..16777215) MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the IO Port Id this TS is connected to." ::= {v51VarCfgEntry 7} v51VarCfgEfL3Addr OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the Address of the IO port this TS is connected to. The IO port is identified according to its Address: - for ISDN ports: EF Address. Valid values: 0..8175 - for PSTN ports: L3 Address. Valid values: 0..32767 65535=notApplicable (FFFF)." ::= {v51VarCfgEntry 8} v51VarCfgFTypeCch OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), ts15 (2), ts16 (3), ts31 (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates which TS will be used for F-Type C channel." ::= {v51VarCfgEntry 9} v51VarCfgPTypeCch OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), ts15 (2), ts16 (3), ts31 (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates which TS will be used for P-Type C channel." ::= {v51VarCfgEntry 10} v51VarCfgConSlt OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Slot containing the IO port this TS is connected to." ::= {v51VarCfgEntry 11} v51VarCfgConPrt OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The IO Port this TS is connected to. Valid values: exPrt1 (1)..exPrt12 (12), inPrt1(101)..inPrt4(104). 100=noConnect " ::= {v51VarCfgEntry 12} v51VarCfgIoState OBJECT-TYPE SYNTAX INTEGER { notUsed (1), normal (2), blockReqDenied (3), remoteBlocked (4), localBlocked (5), unblockReqDenied(6), duringBlock (7), duringUnblock (8), localLoop (9), remoteLoop (10), localUnblock (11), remoteUnblock (12) } MAX-ACCESS read-only STATUS current DESCRIPTION "The State of the IO port this TS is connected to. This object is not applicable for v51VarCfgIndex=255=TmpCnfg. normal(2) - will be used for operating normally (operate) localBlocked(5) - will be used for general Block state" ::= {v51VarCfgEntry 13} v51VarCfgBlock OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), unBlock (2), block (3), blockRequest (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates if this TS will be Blocked or not and how: block - done locally blockRequest - according to external request of the telephone exchange." ::= {v51VarCfgEntry 14} v51VarCfgExtDch OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates if this TS is an ISDN D channel that comes via Bypass from a non-V5.1 ML." ::= {v51VarCfgEntry 15} v51VarCfgExtDchSlot OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is applicable only if v51VarCfgExtDch=yes(3). It indicates the Slot of the non-V5.1 ML on which the External D channel TS is defined (and is transferred via Bypass between the V5.1 ML and the non-V5.1 ML.)" ::= {v51VarCfgEntry 16} v51VarCfgExtDchPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object is applicable only if v51VarCfgExtDch=yes(3). It indicates the Port on the Slot of 'v51VarCfgExtDchSlot' of the non-V5.1 ML on which the External D channel TS is defined (and is transferred via Bypass between the V5.1 ML and the non-V5.1 ML.) Valid values: exPrt1 (1)..exPrt4 (4), inPrt1(101)..inPrt4(104). 100=noConnect " ::= {v51VarCfgEntry 17} v51VarCfgExtDchTs OBJECT-TYPE SYNTAX Integer32 (0..31) MAX-ACCESS read-write STATUS current DESCRIPTION "This object is applicable only if v51VarCfgExtDch=yes(3). It indicates the TS on the non-V5.1 ML on which the External D channel TS is defined (and is transferred via Bypass between the V5.1 ML and the non-V5.1 ML.) 0=notApplicable " ::= {v51VarCfgEntry 18} v51VarCfgExtDchCmpr OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is applicable only if v51VarCfgExtDch=yes(3). It indicates if this ISDN D channel TS is Compressed or not." ::= {v51VarCfgEntry 19} v51VarCfgExtDchRate OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), twoBits (2), fourBits (3), eightBits (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is applicable only if v51VarCfgExtDch=yes(3). It indicates the Rate of the ISDN D channel." ::= {v51VarCfgEntry 20} v51VarCfgExtDchStartBit OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "This object is applicable only if v51VarCfgExtDch=yes(3). It indicates the Start Bit of the ISDN D channel on the TS of the non-V5.1 ML on which it is defined. Valid values: - for v51VarCfgExtDchRate=twoBits(2): 1, 3, 5, 7 - for v51VarCfgExtDchRate=fourBits(2): 1, 5 - for v51VarCfgExtDchRate=eightBits(2): 1 - 0=notApplicable " ::= {v51VarCfgEntry 21} --V5.1 ML tables v51MlCmdAndStatus OBJECT IDENTIFIER ::= {v51Ml 1} v51MlCnfg OBJECT IDENTIFIER ::= {v51Ml 2} --ML command/status table v51MlTable OBJECT-TYPE SYNTAX SEQUENCE OF V51MlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Variant Command and Status table." ::= { v51MlCmdAndStatus 1} v51MlEntry OBJECT-TYPE SYNTAX V51MlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table v51MlTable." INDEX {v51MlSltIdx, v51MlPrtIdx} ::= { v51MlTable 1} V51MlEntry ::= SEQUENCE { v51MlSltIdx INTEGER, v51MlPrtIdx Integer32, v51MlCurrActiveVar Integer32, v51MlLeActiveReqVar Integer32, v51MlProtocolState INTEGER, v51MlUserActiveVarReq Integer32, v51MlDeleteVarReq Integer32, v51MlSaveVariant Integer32, v51MlReadVariant Integer32, v51MlDeactivateVar Integer32 } v51MlSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Slot Index" ::= {v51MlEntry 1} v51MlPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number of the ML having V5 interface. Valid values: exPrt1 (1)..exPrt4 (4), inPrt1(101)..inPrt4(104)" ::= {v51MlEntry 2} v51MlCurrActiveVar OBJECT-TYPE SYNTAX Integer32 (0..128) MAX-ACCESS read-only STATUS current DESCRIPTION "The currently Active Variant Id. on this ML. 128=none." ::= {v51MlEntry 3} v51MlLeActiveReqVar OBJECT-TYPE SYNTAX Integer32 (0..128) MAX-ACCESS read-only STATUS current DESCRIPTION "The Variant Id. that the Local Exchange (LE) requested to be Active on this ML. 128=none." ::= {v51MlEntry 4} v51MlProtocolState OBJECT-TYPE SYNTAX INTEGER { sysStartUp (1), waitForVarId (2), activatePstn (3), restart1 (4), inService (5), restart2 (6), restart3 (7), waitV5Init (8), switchOver (9), ctrlDataLinkRel1 (10), ctrlDataLinkRel2 (11), ctrlDataLinkRel3 (12), outOfService (13), waitE1Reports (14), waitL2StartUp (15), waitLinkId (16), waitRestart (17), notDefined (18) } MAX-ACCESS read-only STATUS current DESCRIPTION "Protocol State of the ML Active Variant. - sysStartUp - an Establish request arrived to the V5.1 interface. - waitForVarId - the variant and the Interface Id were requested during the system start-up procedure. - activatePstn - activation of the PSTN Data Link was requested during the system start-up procedure. - restart1 - the PSTN restart procedure is in process. - inService - the V5.1 interface is IN SERVICE. - restart2 - the V5.1 is in AN5 state (sends restart complete to all PSTN protocols and changes status to In-Service). - restart3 - the V5.1 is in AN6 state (sends restart complete to all PSTN protocols and changes status to In-Service). - waitV5Init - this state is entered when the system's management is in In-Service state, Switch to a new Variant is received and V5.1 interface will not be restarted. - switchOver - this state is entered when the system's management is in In-Service state, Switch to a new Variant is received and V5.1 interface will be restarted. - ctrlDataLinkRel1 - this state is entered when the system's management is in In-Service state and Release Indication is received. Timer TC1 is running in this state. - ctrlDataLinkRel2 - this state is entered on reception of Release-Indication in 'restart3' state. - outOfService - the V5.1 interface is Out-of-Service. - notDefined - V5.1 is not defined for this interface." ::= {v51MlEntry 5} v51MlUserActiveVarReq OBJECT-TYPE SYNTAX Integer32 (0..127) MAX-ACCESS read-write STATUS current DESCRIPTION "User Request to turn a certain Variant of the ML, to Active. This object specifies the Variant Id. requested by user to be Active. User's request is not always accepted." ::= {v51MlEntry 6} v51MlDeleteVarReq OBJECT-TYPE SYNTAX Integer32 (0..127) MAX-ACCESS read-write STATUS current DESCRIPTION "User Request to Delete a certain Variant of the ML. This object specifies the Variant Id. requested by user to be Delete. User's request will not be accepted if the required Varian Id is Active or during Reprovision process." ::= {v51MlEntry 7} v51MlSaveVariant OBJECT-TYPE SYNTAX Integer32 (0..127) MAX-ACCESS read-write STATUS current DESCRIPTION "User Command to Save the TmpCnfg Variant data to a certain Variant Id of the selected ML, in Current Cnfg. The value of this object specifies the target Variant Id. The data transferred should be: v51VarTable and v51VarCnfgTable parameters. Upon Set command, the MUX will initiate a Sanity-Check process first: - If successful, the actual transfer will be performed. - If warnings are detected, the user will have to perform the command again to confirm the operation. - If errors are detected, transfer will NOT be performed." ::= {v51MlEntry 8} v51MlReadVariant OBJECT-TYPE SYNTAX Integer32 (0..127) MAX-ACCESS read-write STATUS current DESCRIPTION "User Command to Read data from a certain Variant Id of the selected ML, (in Current Cnfg) to the TmpCnfg. The value of this object specifies the source Variant Id. The data transferred should be: v51VarTable and v51VarCnfgTable parameters. The operation is valid only on existing Variants of the ML." ::= {v51MlEntry 9} v51MlDeactivateVar OBJECT-TYPE SYNTAX Integer32 (0..127) MAX-ACCESS read-write STATUS current DESCRIPTION "User Request to Deactivate a certain Variant of the ML. This object specifies the Variant Id. requested by user to be Deactivated. User can deactivate a variant having Active Request status or Active status. Deactivating the variant having Active Status wil stop the V5.1 operations on this link." ::= {v51MlEntry 10} --ML Cnfg Table v51MlCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF V51MlCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= { v51MlCnfg 1} v51MlCnfgEntry OBJECT-TYPE SYNTAX V51MlCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table v51MlCnfgTable." INDEX {v51MlCnfgIdx, v51MlCnfgSltIdx, v51MlCnfgPrtIdx} ::= { v51MlCnfgTable 1} V51MlCnfgEntry ::= SEQUENCE { v51MlCnfgIdx Integer32, v51MlCnfgSltIdx INTEGER, v51MlCnfgPrtIdx Integer32, v51MlCnfgIfId Integer32, v51MlCnfgStartupMode INTEGER, v51MlCnfgReprovision INTEGER, v51MlCnfgUnblockIoPorts INTEGER, v51MlCnfgRestartComplete INTEGER } v51MlCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg being accessed. 1..10 = Current Cnfg (data will be the same for all Current Configurations) 255 = TmpCnfg." ::= {v51MlCnfgEntry 1} v51MlCnfgSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Slot Index" ::= {v51MlCnfgEntry 2} v51MlCnfgPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number of the ML having V5 interface. Valid values: exPrt1 (1)..exPrt4 (4), inPrt1(101)..inPrt4(104)" ::= {v51MlCnfgEntry 3} v51MlCnfgIfId OBJECT-TYPE SYNTAX Integer32 (0..99999999) MAX-ACCESS read-write STATUS current DESCRIPTION "V5.1 Interface Id." ::= {v51MlCnfgEntry 4} v51MlCnfgStartupMode OBJECT-TYPE SYNTAX INTEGER { sync (2), async (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Startup Mode." ::= {v51MlCnfgEntry 5} v51MlCnfgReprovision OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Reprovision Support. - no : no reprovision support (=default) - yes: reprovision is supported." ::= {v51MlCnfgEntry 6} v51MlCnfgUnblockIoPorts OBJECT-TYPE SYNTAX INTEGER { disabled (2), enabled (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Unblock IO Ports on Startup. - disabled - disable sending Unblock request on restart - enabled - request unblock of all IO ports ON RESTART (=default)." ::= {v51MlCnfgEntry 7} v51MlCnfgRestartComplete OBJECT-TYPE SYNTAX INTEGER { uponLeRestart (2), uponPstnProtocolAck (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Send Restart Complete. - uponLeRestart - after receiving restart from the other side. - uponPstnProtocolAck - after receiving restart ack from PSTN protocol (=default)." ::= {v51MlCnfgEntry 8} --V5.1 Access port tables v51IoCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF V51IoCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= { v51AccessPort 1} v51IoCnfgEntry OBJECT-TYPE SYNTAX V51IoCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table v51IoCnfgTable." INDEX {v51IoCnfgIdx, v51IoCnfgSltIdx, v51IoCnfgPrtIdx} ::= { v51IoCnfgTable 1} V51IoCnfgEntry ::= SEQUENCE { v51IoCnfgIdx Integer32, v51IoCnfgSltIdx INTEGER, v51IoCnfgPrtIdx Integer32, v51IoCnfgSType INTEGER, v51IoCnfgFType INTEGER, v51IoCnfgPType INTEGER } v51IoCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg being accessed. 1..10 = Current Cnfg (data will be the same for all Current Configurations) 255 = TmpCnfg." ::= {v51IoCnfgEntry 1} v51IoCnfgSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Slot Index" ::= {v51IoCnfgEntry 2} v51IoCnfgPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number of the Io having V5 interface. Valid values: exPrt1 (1)..exPrt16 (16)" ::= {v51IoCnfgEntry 3} v51IoCnfgSType OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates if S Type Signaling will be used by this ISDN port (yes/no). notApplicable - for PSTN ports." ::= {v51IoCnfgEntry 4} v51IoCnfgFType OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates if F Type Signaling will be used by this ISDN port (yes/no). notApplicable - for PSTN ports." ::= {v51IoCnfgEntry 5} v51IoCnfgPType OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates if P Type Signaling will be used by this ISDN port (yes/no). notApplicable - for PSTN ports." ::= {v51IoCnfgEntry 6} -- Traps --NOTIFICATIONS v51IfEvents OBJECT-IDENTITY STATUS current DESCRIPTION "The events for the WAN V5.1." ::= { v51If 0 } activeVariantTrap NOTIFICATION-TYPE OBJECTS { v51MlCurrActiveVar } STATUS current DESCRIPTION "This trap is sent when the Active Variant of a Link is changed (that includes the case when a user performs Save to the Variant that is Active)." ::= { v51IfEvents 1 } -- -- file :v:\doc\rdv\mib\ver485\voip\voip.txt -- -- -------------------------------------------------------------------------------------- --Title: RAD's Voice Over IP MIB --By: Liora Gafni --Date : 28-Sep-99 --Description: This MIB contains parameters that were not defined in the ITU H.341 MIB -- and are required for RAD products. -- --Last Update: 28/05/02 --By: Liora Gafni --File: v:\doc\rdv\mib\ver485\voip\voip.txt -- -------------------------------------------------------------------------------------- --IMPORTS -- enterprises FROM SNMPv2-SMI -- DisplayString FROM SNMPv2-TC -- IpAddress FROM SNMPv2-SMI -- OCTET STRING FROM SNMPv2-TC -- OBJECT-TYPE FROM RFC1212 -- TAddress FROM SNMPv2-TC -- MmTAddressTag,MmEndpointID, -- MmAliasAddress,MmH323EndpointType, -- MmGatekeeperID,MmGlobalIdentifier FROM MULTI-MEDIA-MIB-TC; --wanGen OBJECT IDENTIFIER ::= {radWan 1} (see mpmx.txt) voipWanGen OBJECT IDENTIFIER ::= {wanGen 7} --(see mpmx.txt) -- VOIP Card Configuration voipCardConfig OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object determines the VOIP card configuration. Bit 0 (LSB): if 1 - a GK exists. If 0 - no GK exists in this card. The other bits may be used in the future." ::= { voipWanGen 1 } -- GK General Parameters table gkGenTable OBJECT-TYPE SYNTAX SEQUENCE OF GkGenEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "General parameters for the VOIP GateKeeper." ::= { voipWanGen 2 } gkGenEntry OBJECT-TYPE SYNTAX GkGenEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table gkGenTable." INDEX {ifIndex} ::= { gkGenTable 1} GkGenEntry ::= SEQUENCE { gkGenCallMode INTEGER, gkGenMaxConnections Integer32, gkGenDefaultDistance Integer32, gkGenOutOfZoneDist Integer32, gkGenCallAcceptPolicy INTEGER, gkGenIrqInterval Integer32, gkGenQ931Port Integer32, gkGenRasPort Integer32, gkGenRegPolicy INTEGER, gkGenZoneId OCTET STRING } gkGenCallMode OBJECT-TYPE SYNTAX INTEGER { direct (2), routed (3), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameters shows whether the calls will go through the GK (routed) or whether the calls will be direct from Endpoint to Endpoint without involving the GK (direct)." ::= {gkGenEntry 1} gkGenMaxConnections OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "MAX no. of connections enabled by the GK to take place simultaneously. If the MAX no. of calls is exceeded, a busy signal will be returned." ::= {gkGenEntry 2} gkGenDefaultDistance OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The Distance allowed for endpoints that are registered dynamically." ::= {gkGenEntry 3} gkGenOutOfZoneDist OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The Distance allowed for an out of zone endpoint that is making a call through the gatekeeper." ::= {gkGenEntry 4} gkGenCallAcceptPolicy OBJECT-TYPE SYNTAX INTEGER { acceptAll (2), registeredOnly (3), predefinedOnly (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the policy concerning the incoming phone calls. The importance of this parameter is for bidding and security matters. Accept All - all the incoming calls are accepted. Registered Only - the calls are accepted from the predefined endpoints only, which are endpoints that have previously registered with the gatekeeper. Predefined Only - with this policy only the calls from the statically registered endpoints can be accepted." ::= {gkGenEntry 5} gkGenIrqInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "In order for the Gatekeeper to determine if an endpoint is turned off, or has otherwise entered a failure mode, the Gatekeeper may use the Information Request (IRQ) to poll the endpoints at the certain interval (in seconds). THE IRQ INTERVAL controls the frequency the gk sends IRQ messages. This message is sent to all on-line endpoints registered as dynamic in order to verify they are really on-line. This is done to detect terminals that shut off without sending the required URQ message that notifies the gk that they are no longer on-line. Endpoints failing to respond too many times have their dynamic properties unregistered. Choosing the desired interval should take into account the following factors : IRQ messages add to the traffic already present over the network and the shorter the interval the more IRQ messages will be sent. On the other hand the longer the delay the longer it will take for the gk to detect dynamic registrations that have ceased to actually be on-line. Note that the IRQ interval relates to each endpoint and the actual number of the IRQ messages the gk will create should be multiplied by the number of endpoints registered dynamically." ::= {gkGenEntry 6} gkGenQ931Port OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Q.931 Port no." ::= {gkGenEntry 7} gkGenRasPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "RAS Port no." ::= {gkGenEntry 8} gkGenRegPolicy OBJECT-TYPE SYNTAX INTEGER { acceptAll (2), predefinedOnly (3), registrationReject (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Policy of dynamic registrations in the Gatekeeper. The GK will act according to the following policies: Accept All - The GK will enable all requesting endpoints to register dynamically. Predefined Only - The GK will enable registration of endpoints that were registered previously via static registration. Registration Reject - No endpoint may register dynamically." ::= {gkGenEntry 9} gkGenZoneId OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Zone Identifier: 1 or 2 digits, (0-9)(1-9)." ::= {gkGenEntry 10} -- GK Endpoints Table gkEndpTable OBJECT-TYPE SYNTAX SEQUENCE OF GkEndpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table containing the Endpoints that are registered (statically & Dynamically) with the current GK." ::= { voipWanGen 3 } gkEndpEntry OBJECT-TYPE SYNTAX GkEndpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table gkEndpTable." INDEX {ifIndex, gkEndpAliasTag, gkEndpAlias} ::= { gkEndpTable 1} GkEndpEntry ::= SEQUENCE { gkEndpAliasTag MmAliasTag, gkEndpAlias MmAliasAddress, gkEndpRowStatus RowStatus, gkEndpAddressTag MmTAddressTag, gkEndpAddress TAddress, gkEndpID MmEndpointID, gkEndpType MmH323EndpointType, gkEndpQ931Port Integer32, gkEndpDistance Integer32, gkEndpRegMode INTEGER, gkEndpSetOnline INTEGER, gkEndpStatus INTEGER } gkEndpAliasTag OBJECT-TYPE SYNTAX MmAliasTag MAX-ACCESS read-only STATUS current DESCRIPTION "Alias Tag of the Endpoint." ::= {gkEndpEntry 1} gkEndpAlias OBJECT-TYPE SYNTAX MmAliasAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Alias of the Endpoint." ::= {gkEndpEntry 2} gkEndpRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The row status of the entry. This object is required to create or delete rows remotely by a manager. " ::= {gkEndpEntry 3} gkEndpAddressTag OBJECT-TYPE SYNTAX MmTAddressTag MAX-ACCESS read-create STATUS current DESCRIPTION "Address Tag of Endpoint." ::= {gkEndpEntry 4} gkEndpAddress OBJECT-TYPE SYNTAX TAddress MAX-ACCESS read-create STATUS current DESCRIPTION "Address of Endpoint." ::= {gkEndpEntry 5} gkEndpID OBJECT-TYPE SYNTAX MmEndpointID MAX-ACCESS read-create STATUS current DESCRIPTION "Endpoint Identifier." ::= {gkEndpEntry 6} gkEndpType OBJECT-TYPE SYNTAX MmH323EndpointType MAX-ACCESS read-create STATUS current DESCRIPTION "This parameter shows whether the current endpoint is a GW or Terminal or any other type of H.323 endpoint." ::= {gkEndpEntry 7} gkEndpQ931Port OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Q.931 Port no." ::= {gkEndpEntry 8} gkEndpDistance OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Distance from the current endpoint to the GateKeeper with which it is Registered." ::= {gkEndpEntry 9} gkEndpRegMode OBJECT-TYPE SYNTAX INTEGER { dynamic (2), static (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter shows whether the Endpoint Registered Dynamically or Statically." ::= {gkEndpEntry 10} gkEndpSetOnline OBJECT-TYPE SYNTAX INTEGER { uponDynamicReg (2), always (3) } MAX-ACCESS read-create STATUS current DESCRIPTION "This parameter shows whether the endpoint will always be online or whether it will be on line upon Dynamic Registration only." ::= {gkEndpEntry 11} gkEndpStatus OBJECT-TYPE SYNTAX INTEGER { online (2), offline (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter shows whether the endpoint is currently online." ::= {gkEndpEntry 12} -- GK Neighbors table gkNeighbTable OBJECT-TYPE SYNTAX SEQUENCE OF GkNeighbEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of GateKeepers that are Neighbors of the current Gatekeeper." ::= { voipWanGen 4 } gkNeighbEntry OBJECT-TYPE SYNTAX GkNeighbEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table gkNeighbTable." INDEX {ifIndex, gkNeighbAddressTag, gkNeighbAddress} ::= { gkNeighbTable 1} GkNeighbEntry ::= SEQUENCE { gkNeighbAddressTag MmTAddressTag, gkNeighbAddress TAddress, gkNeighbRowStatus RowStatus, gkNeighbLeadingAlias MmAliasAddress, gkNeighbDistance Integer32, gkNeighbDescription MmGatekeeperID } gkNeighbAddressTag OBJECT-TYPE SYNTAX MmTAddressTag MAX-ACCESS read-only STATUS current DESCRIPTION "Tag of GK or GW address." ::= {gkNeighbEntry 1} gkNeighbAddress OBJECT-TYPE SYNTAX TAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Address of GK or GW." ::= {gkNeighbEntry 2} gkNeighbRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The row status of the entry. This object is required to create or delete rows remotely by a manager. " ::= {gkNeighbEntry 3} gkNeighbLeadingAlias OBJECT-TYPE SYNTAX MmAliasAddress MAX-ACCESS read-create STATUS current DESCRIPTION "This is the Leading Alias Address (Zone Prefix) that will be dialed in order to reach the specific neighbor." ::= {gkNeighbEntry 4} gkNeighbDistance OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Distance between the local GateKeeper and the Neighbor GateKeeper." ::= {gkNeighbEntry 5} gkNeighbDescription OBJECT-TYPE SYNTAX MmGatekeeperID MAX-ACCESS read-create STATUS current DESCRIPTION "ASCII String Description for identifying the Neighbor." ::= {gkNeighbEntry 6} -- GW General Parameters table gwGenTable OBJECT-TYPE SYNTAX SEQUENCE OF GwGenEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "General parameters for the VOIP GateWay." ::= { voipWanGen 5 } gwGenEntry OBJECT-TYPE SYNTAX GwGenEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table gwGenTable." INDEX {ifIndex} ::= { gwGenTable 1} GwGenEntry ::= SEQUENCE { gwGenGwId MmEndpointID, gwGenQ931Port Integer32, gwGenRasPort Integer32, gwGenMode INTEGER, gwGenVoipExtension Integer32, gwGenRemGwAddress TAddress, gwGenMaxConnections Integer32, gwGenTOS OCTET STRING, gwGenBackupGkAddr TAddress, gwGenTimeToRegister Integer32 } gwGenGwId OBJECT-TYPE SYNTAX MmEndpointID MAX-ACCESS read-write STATUS current DESCRIPTION "A character string of up to 20 characters identifying the gateway." ::= {gwGenEntry 1} gwGenQ931Port OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The Q.931 port no. of the Gateway." ::= {gwGenEntry 2} gwGenRasPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The RAS port no. of the Gateway." ::= {gwGenEntry 3} gwGenMode OBJECT-TYPE SYNTAX INTEGER { disable (2), cvsIp (3), standard (4), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "GW Mode: disable - The GW is not activated. cvsIp - CVS is a Compressed Voice System. The GW will compress voice calls at a ratio of 16 to 1. 16 time slots of E1/T1 will be compressed into 1 E1/T1 time slot. When this mode is used the Gateway can communicate directly with another Gateway without a Gatekeeper. standard - This mode includes a Gateway & a Gatekeeper." ::= {gwGenEntry 4} gwGenVoipExtension OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This is the extension number of the VOIP protocol. It is used for the Voice card to identify the calls made through the VoIP card. The user may choose an arbitrary value for this field, the only restriction is that there must be no other entity registered with the same extension number." ::= {gwGenEntry 5} gwGenRemGwAddress OBJECT-TYPE SYNTAX TAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the remote gateway address (IP + port). It is important for gateway to gateway connection." ::= {gwGenEntry 6} gwGenMaxConnections OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "MAX no. of connections enabled by the GW." ::= {gwGenEntry 7} gwGenTOS OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Type of Service. The BIT Format is consistent with the IP standard: +-----+-----+-----+-----+-----+-----+-----+-----+ | | | | | PRECEDENCE | TYPE OF SERVICE | 0 | | | | | +-----+-----+-----+-----+-----+-----+-----+-----+ 0 1 2 3 4 5 6 7 At present, only 1 BYTE will be used, bits 0 (MSB) - 7 (LSB). The precedence consists of 3 BITS (0-2): 111 - Network Control 110 - Internetwork Control 101 - CRITIC/ECP 100 - Flash Override 011 - Flash 010 - Immediate 001 - Priority 000 - Routine The TOS values BITS (3-5): Bit 3 is the Delay: 0 = Normal Delay, 1 = Low Delay. Bit 4 is the Throughput: 0 = Normal Throughput, 1 = High Throughput. Bit 5:is the Reliability: 0 = Normal Reliability, 1 = High Reliability. Bits 6 & 7 are for future use and their current value is 0." ::= {gwGenEntry 8} gwGenBackupGkAddr OBJECT-TYPE SYNTAX TAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the backup gatekeeper address (IP + port). When the backup GK is active, all the calls will be routed to it and it will be responsible for their address translation. The first GK address is defined in the standard H.341 MIB." ::= {gwGenEntry 9} gwGenTimeToRegister OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The GW should register every 'Time to Register' seconds with the GK. The 'Time to Register' range is from 0 to 900 seconds in intervals of 60 seconds. 0 means Never. When the GK becomes active the Gateways that are up can register so that the GK has an updated list of active Registered Gateways." ::= {gwGenEntry 10} -- RAD's addition to h245ConfigurationTable radH245ConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF RadH245ConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains information about H.245 configuration parameters. It is a list of configuration parameter entries. The number of entries equals to the number of H.245 stacks in a system." ::= { voipWanGen 6 } radH245ConfigEntry OBJECT-TYPE SYNTAX RadH245ConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "It contains objects that describe the H.245 configuration parameters." INDEX { ifIndex } ::= { radH245ConfigTable 1 } RadH245ConfigEntry ::= SEQUENCE { h245MaxJitter Integer32, h245Tunneling INTEGER } h245MaxJitter OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Maximum peak to peak delivery (in miliseconds) of audio packets to the transport layer that the transmitter shall cause." ::= {radH245ConfigEntry 1} h245Tunneling OBJECT-TYPE SYNTAX INTEGER { disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable enables or disables the usage of Tunneling." ::= {radH245ConfigEntry 2} -- RTP Multiplexing rtpMultiplexTable OBJECT-TYPE SYNTAX SEQUENCE OF RtpMultiplexEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "RTP Multiplexing table. RTP Multiplexing: In IP telephony system, the addition of packet headers, including IP, UDP and RTP headers, increases the header overhead, decreasing efficient transmission. Also, because of large numbers of short voice packets flowing into the network, Internet load increases, eventually resulting in large delay and packet loss. RTP Multiplexing is a way to send multiple RTP packets between a pair of Gateways, with a single IP frame. This will reduces the header overhead and decreases delay by enabling voice transmission with fewer packets." ::= { voipWanGen 7 } rtpMultiplexEntry OBJECT-TYPE SYNTAX RtpMultiplexEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table rtpMultiplexTable." INDEX {ifIndex} ::= { rtpMultiplexTable 1} RtpMultiplexEntry ::= SEQUENCE { rtpMultiplexedRtp INTEGER, rtpMultiplexFrameSize Integer32, rtpMultiplexInterval Integer32 } rtpMultiplexedRtp OBJECT-TYPE SYNTAX INTEGER { disable (2), multiplexType1 (3), multiplexType2 (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "RTP Multiplexing is a way to send multiple RTP packets with a single IP frame. This will reduce the header overhead and decrease the delay by enabling voice transmission with fewer packets. The option of this field are: Disable - No RTP Multiplexing. multiplexType1 - medium level of compression for RTP multiplexing. multiplexType2 - high level of compression for RTP multiplexing. Using the High Compression algorithm is more efficient but will cause the loss of some RTP header information. If RTP statistics are important, the medium compression must be selected." ::= {rtpMultiplexEntry 1} rtpMultiplexFrameSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the maximum size in Bytes of the multiplexed frame. In some cases this must be limited to avoid IP fragmentation, which makes the multiplexing useless, and can also decrease the damage in case of the frame loss. At present the size is 1500." ::= {rtpMultiplexEntry 2} rtpMultiplexInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the maximum amout of time (msec.) between multiplexed frames that are sent. Legal values: 10-90 msec." ::= {rtpMultiplexEntry 3} -- -- file :v:\doc\rdv\mib\ver485\ipmux.txt -- --Title: RAD's IP-MUX PRODUCT MIB --Version: 1.0 --Date: 27.05.99 --By: Ilana Schvetz --File: ipmux.txt -- --Last update: 01/08/02 by Shlomo Shoham ip2If OBJECT IDENTIFIER ::= { diverseIfWanGen 7 } -- ip2If Configuration table ip2IfTable OBJECT-TYPE SYNTAX SEQUENCE OF Ip2IfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Channels Configuration Table." ::= { ip2If 1 } ip2IfEntry OBJECT-TYPE SYNTAX Ip2IfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Application layer configuration per link" INDEX { ip2IfChannelIndex } ::= { ip2IfTable 1 } Ip2IfEntry ::= SEQUENCE { ip2IfChannelIndex Integer32, ip2IfRowStatus RowStatus, ip2IfOperStatus INTEGER, ip2IfAdminStatus INTEGER, ip2IfDestAddr IpAddress, ip2IfNextHop IpAddress, ip2IfDestPort Integer32, ip2IfMacAddr MacAddress, ip2IfJitterBuffer Integer32, ip2IfTos Integer32, ip2IfTDMBytesInFrame Integer32, ip2IfVlanSupport INTEGER, ip2IfVlanIdentifier Integer32, ip2IfVlanFramePriority Integer32, ip2IfExitPort INTEGER, ip2IfVoiceOos OCTET STRING, ip2IfDataOos OCTET STRING, ip2IfBundleUsage Integer32, ip2IfOAM OCTET STRING, ip2IfTDMoIpMode INTEGER, ip2IfTimeElapsed Integer32, ip2IfValidIntervals Integer32, ip2IfFarEndType INTEGER, ip2IfRdnState INTEGER } ip2IfChannelIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The channel index, which is actualy the bundle ID." ::= { ip2IfEntry 1 } ip2IfRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This parameter allows NMS to create/delete entries of this table." ::= { ip2IfEntry 2 } ip2IfOperStatus OBJECT-TYPE SYNTAX INTEGER { down (2), up (3), disabled (4), remoteFail(5), localFail (6), unavailable (7), validationFail (8), standby (9), tdmFail (10) } MAX-ACCESS read-only STATUS current DESCRIPTION "The actual link status. remoteFail - No Rx. localFail - No Tx. unavailable - No echo replay or replay with invalid code or when connection is in Test state. valiodationFail - Connection is in not valid state. standby - offline (can be in pre-sync mode). tdmFail - oper status is down cause of failure in the tdm." ::= { ip2IfEntry 3 } ip2IfAdminStatus OBJECT-TYPE SYNTAX INTEGER { down (2), up (3) } MAX-ACCESS read-create STATUS current DESCRIPTION "The desired state of the link." ::= { ip2IfEntry 4 } ip2IfDestAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "The destination IP address." ::= { ip2IfEntry 5 } ip2IfNextHop OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "The next hop to which the frame should be sent. Default value - 0.0.0.0. Upon setting the default value the frame is sent to the default Gateway." ::= { ip2IfEntry 6 } ip2IfDestPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The destination Bundle at the far-end device." ::= { ip2IfEntry 7 } ip2IfMacAddr OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The Destination MAC address of the next hop or destination station." ::= { ip2IfEntry 8 } ip2IfJitterBuffer OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The maximum cell arrival jitter in 10 usec that the reassembly process will tolerate in the cell stream, without producing errors on the CBR service interface. Default value - 100. For KM2100: KML.11 - The range that will be used is 3...300 msec in steps of 1 msec." ::= { ip2IfEntry 9 } ip2IfTos OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The TOS (Type of Service) value: 0..255." ::= { ip2IfEntry 10 } ip2IfTDMBytesInFrame OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The number of TDM bytes to be placed in a single IP frame payload." ::= { ip2IfEntry 11 } ip2IfVlanSupport OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-create STATUS current DESCRIPTION "VLAN support (Tagging). no - No support to VLAN. yes - 4 VLAN bytes will be added to the frame." ::= { ip2IfEntry 12} ip2IfVlanIdentifier OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "VLAN ID." ::= { ip2IfEntry 13 } ip2IfVlanFramePriority OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "VLAN Frame priority." ::= { ip2IfEntry 14 } ip2IfExitPort OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), ext1 (2), ext2 (3), auto (4) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object determines to which external port the traffic will be sent. auto - the device will decide automatically the exit port." ::= { ip2IfEntry 15 } ip2IfVoiceOos OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-create STATUS current DESCRIPTION "Voice Out-Of-Service code. Valid range: (0 - FF HEX). For agents that do not support this feature, the value will always be 0." ::= { ip2IfEntry 16 } ip2IfDataOos OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-create STATUS current DESCRIPTION "Data Out-Of-Service code. Valid range: (0 - FF HEX). For agents that do not support this feature, the value will always be 0." ::= { ip2IfEntry 17 } ip2IfBundleUsage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The Bundle Resource usage in Kbps." ::= { ip2IfEntry 18 } ip2IfOAM OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-create STATUS current DESCRIPTION "This parameter determine the OAM configuration. The LSB (Bit 0 the most right one) is used for OAM connectivity. Values: 0 = disable, 1= enable." ::= { ip2IfEntry 19 } ip2IfTDMoIpMode OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), static (2), dynamicLES (3), dynamicCAS (4), cesOverIp (5) } MAX-ACCESS read-create STATUS current DESCRIPTION "The TDMoIP Mode configuration. Static- means TS can Tx any time. dynamicLES - means TS can Tx only when line is enabled according to LES protocol. dynamicCAS - means TS can Tx only when line is enabled according to CAS protocol. cesOverIp - use for information that this bundle is used for CES Over IP." ::= { ip2IfEntry 20 } ip2IfTimeElapsed OBJECT-TYPE SYNTAX Integer32 (0..899) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of seconds that have elapsed since the beginning of the current error-measurement period. If, for some reason, such as an adjustment in the system's time-of-day clock, the current interval exceeds the maximum value, the agent will return the maximum value." ::= {ip2IfEntry 21 } ip2IfValidIntervals OBJECT-TYPE SYNTAX Integer32 (0..96) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of previous intervals for which data was collected. The value will be 96 unless the interface was brought online within the last 24 hours, in which case the value will be the number of complete 15 minute intervals since the interface has been online. " ::= {ip2IfEntry 22 } ip2IfFarEndType OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), e1 (2), t1Esf (3), t1D4 (4) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object defines the type of the Far-End device. This data is important for signaling." ::= { ip2IfEntry 23 } ip2IfRdnState OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), none (2), primary (3), secondary (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object defines the role this bundle plays in the redundancy scheme: none(2) - means this bundle is not part of redundancy pair. primary/ secondary - means this bundle is not part of redundancy pair, and that is the primary bundle or the secondary bunle. " ::= { ip2IfEntry 24 } ip2IfTDMFrameBytes OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The number of TDM bytes to be placed in a single IP frame payload." ::= { ip2If 2 } ip2IfTosValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The TOS value to write in the IP frame." ::= { ip2If 3 } ip2IfVlanTagging OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "VLAN support. no - No support to VLAN. yes - 4 VLAN bytes will be added to the frame." ::= { ip2If 4 } ip2IfVlanID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "VLAN ID." ::= { ip2If 5 } ip2IfVlanPriority OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Frame priority." ::= { ip2If 6 } -- ip2If Statistics table ip2IfStatTable OBJECT-TYPE SYNTAX SEQUENCE OF Ip2IfStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Channels (Bundles) Statistics Table." ::= { ip2If 7 } ip2IfStatEntry OBJECT-TYPE SYNTAX Ip2IfStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "IP Statistics per bundle" INDEX { ip2IfStatChIndex } ::= { ip2IfStatTable 1 } Ip2IfStatEntry ::= SEQUENCE { ip2IfStatChIndex Integer32, ip2IfStatSeqErrors Integer32, ip2IfStatBufUnderflows Integer32, ip2IfStatBufOverflows Integer32, ip2IfStatTxOnTimeInterval Counter32, ip2IfStatTxOnMaxSize Counter32, ip2IfStatRxSignaling Counter32, ip2IfStatRxVoice Counter32, ip2IfStatRxHdlc Counter32, ip2IfStatTxSignaling Counter32, ip2IfStatTxVoice Counter32, ip2IfStatTxHdlc Counter32, ip2IfStatRdnFlip Counter32 } ip2IfStatChIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The channel index, which is actualy the bundle ID." ::= { ip2IfStatEntry 1 } ip2IfStatSeqErrors OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of times that the sequence number of an incoming Frame causes a transition from the 'sync' state to the 'out of sequence' state." ::= { ip2IfStatEntry 2 } ip2IfStatBufUnderflows OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of buffer underflows. This records the count of the number of times the Receive (Eth to TDM) buffer underflows. In the case of a continuous underflow caused by a loss of Frame flow, a single buffer underflow should be counted." ::= { ip2IfStatEntry 3 } ip2IfStatBufOverflows OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of buffer overflows. This records the count of the number of times the Receive (Eth to TDM) buffer overflows." ::= { ip2IfStatEntry 4 } ip2IfStatTxOnTimeInterval OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of frames that were transmitted due to time interval elapse. The user can choose to Tx the Frame when it reaches the Max size or when the packetizing time interval elapses. The packetizing time interval is the interval in msec that it takes to build a Max. size frame." ::= { ip2IfStatEntry 5 } ip2IfStatTxOnMaxSize OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of frames that were transmitted due to reaching max. frame size. The user can choose to Tx the Frame when it reaches the Max size or when the packetizing time interval elapses." ::= { ip2IfStatEntry 6 } ip2IfStatRxSignaling OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of signaling frames that were received." ::= { ip2IfStatEntry 7 } ip2IfStatRxVoice OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of voice frames that were received." ::= { ip2IfStatEntry 8 } ip2IfStatRxHdlc OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of HDLC frames that were received." ::= { ip2IfStatEntry 9 } ip2IfStatTxSignaling OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of signaling frames that were transmitted." ::= { ip2IfStatEntry 10 } ip2IfStatTxVoice OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of voice frames that were transmitted." ::= { ip2IfStatEntry 11 } ip2IfStatTxHdlc OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of HDLC frames that were transmitted." ::= { ip2IfStatEntry 12 } ip2IfStatRdnFlip OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of redundancy flips occured. This parameter counts only flips from this bundle to the other bundle in the redundancy couple." ::= { ip2IfStatEntry 13 } ip2IfRateLimit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum rate permitted to transfer via the network portin Mbps." ::= { ip2If 8 } -- ip2If Port table ip2IfPortTable OBJECT-TYPE SYNTAX SEQUENCE OF Ip2IfPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Port Table." ::= { ip2If 9 } ip2IfPortEntry OBJECT-TYPE SYNTAX Ip2IfPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Application layer configuration per Port" INDEX { ip2IfPortIndex } ::= { ip2IfPortTable 1 } Ip2IfPortEntry ::= SEQUENCE { ip2IfPortIndex Integer32, ip2IfPortUsage Integer32, ip2IfPortMask INTEGER, ip2IfPortTotalThroughput Integer32 } ip2IfPortIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The Port index, which is actualy the ifIndex." ::= { ip2IfPortEntry 1 } ip2IfPortUsage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the usage of the port (percents)." ::= { ip2IfPortEntry 2 } ip2IfPortMask OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), dontMask (2), mask (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter defines whether Agent will mask port's alarms and statistics or not." ::= { ip2IfPortEntry 3 } ip2IfPortTotalThroughput OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the total Throughput of the port in bps." ::= { ip2IfPortEntry 4 } -- ip2If Current Statistics table ip2IfCurrentStatTable OBJECT-TYPE SYNTAX SEQUENCE OF Ip2IfCurrentStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Channels (Bundles) Current Statistics Table." ::= { ip2If 10 } ip2IfCurrentStatEntry OBJECT-TYPE SYNTAX Ip2IfCurrentStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "IP Current Statistics per bundle" INDEX { ip2IfChannelIndex } ::= { ip2IfCurrentStatTable 1 } Ip2IfCurrentStatEntry ::= SEQUENCE { ip2IfCurrentStatSeqErrors Counter32, ip2IfCurrentStatBufUnderflows Counter32, ip2IfCurrentStatBufOverflows Counter32, ip2IfCurrentStatMaxDelayVar Integer32 } ip2IfCurrentStatSeqErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of times that the sequence number of an incoming Frame causes a transition from the 'sync' state to the 'out of sequence' state in the current interval." ::= { ip2IfCurrentStatEntry 1 } ip2IfCurrentStatBufUnderflows OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of buffer underflows in the current interval. This records the count of the number of times the Receive (Eth to TDM) buffer underflows in the current interval. In the case of a continuous underflow caused by a loss of Frame flow, a single buffer underflow should be counted." ::= { ip2IfCurrentStatEntry 2 } ip2IfCurrentStatBufOverflows OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of buffer overflows in the current interval. This records the count of the number of times the Receive (Eth to TDM) buffer overflows in the current interval." ::= { ip2IfCurrentStatEntry 3 } ip2IfCurrentStatMaxDelayVar OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum size of the buffer (in 10's of usec) for the current interval." ::= { ip2IfCurrentStatEntry 4 } -- ip2If Interval Statistics table ip2IfIntervalStatTable OBJECT-TYPE SYNTAX SEQUENCE OF Ip2IfIntervalStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Channels (Bundles) Interval Statistics Table." ::= { ip2If 11 } ip2IfIntervalStatEntry OBJECT-TYPE SYNTAX Ip2IfIntervalStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "IP Interval Statistics per bundle" INDEX { ip2IfChannelIndex, ip2IfIntervalStatIndex } ::= { ip2IfIntervalStatTable 1 } Ip2IfIntervalStatEntry ::= SEQUENCE { ip2IfIntervalStatIndex Integer32, ip2IfIntervalStatSeqErrors Counter32, ip2IfIntervalStatBufUnderflows Counter32, ip2IfIntervalStatBufOverflows Counter32, ip2IfIntervalStatMaxDelayVar Integer32 } ip2IfIntervalStatIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The Interval index, which is actualy the Interval number." ::= { ip2IfIntervalStatEntry 1 } ip2IfIntervalStatSeqErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of times that the sequence number of an incoming Frame causes a transition from the 'sync' state to the 'out of sequence' state in the selected interval." ::= { ip2IfIntervalStatEntry 2 } ip2IfIntervalStatBufUnderflows OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of buffer underflows in the selected interval. This records the count of the number of times the Receive (Eth to TDM) buffer underflows in the selected interval. In the case of a continuous underflow caused by a loss of Frame flow, a single buffer underflow should be counted." ::= { ip2IfIntervalStatEntry 3 } ip2IfIntervalStatBufOverflows OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of buffer overflows in the selected interval. This records the count of the number of times the Receive (Eth to TDM) buffer overflows in the selected interval." ::= { ip2IfIntervalStatEntry 4 } ip2IfIntervalStatMaxDelayVar OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum size of the buffer (in 10's of usec) in the selected interval." ::= { ip2IfIntervalStatEntry 5 } ip2IfLogEvents OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), all (2), oneMinStep (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter defines whether all Jitter Buffer and Sequence Number events will enter to Log File, or enter those events to Log file in one minute steps." ::= { ip2If 12} ip2IfEthSwitchMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), unTagged (2), tagged (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter defines whether Eth Switch is in VLAN Tagged mode." ::= { ip2If 13} --Traps --The numbers 1-4 are used by imx.txt alarmStatusTrap NOTIFICATION-TYPE OBJECTS {atmInterfaceAlarmStatus} STATUS current DESCRIPTION "The trap is sent whenever there is a transition from a no alarm state to a state with at least one active alarm." ::= { radSysWanEvents 5 } systemTrap NOTIFICATION-TYPE OBJECTS { atmNteEventType, agnLed, alarmSeverity } STATUS current DESCRIPTION "This trap alerts of major problems in the device." ::= { radSysWanEvents 6 } alarmLOS NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates Loss Of Signal." ::= { radSysWanEvents 7 } alarmLOF NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates Loss Of Frame." ::= { radSysWanEvents 8 } channelOperStatusTrap NOTIFICATION-TYPE OBJECTS { ip2IfOperStatus } STATUS current DESCRIPTION "This trap is sent upon any change in one or more channels." ::= { radSysWanEvents 9 } alarmAIS NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates AIS." ::= { radSysWanEvents 10 } alarmRDI NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates RDI." ::= { radSysWanEvents 11 } alarmFEBE NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap indicates FEBE." ::= { radSysWanEvents 12 } localConnStatusTrap NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap is sent upon a change in Local connectivity of Bundle connection." ::= { radSysWanEvents 13 } remoteConnStatusTrap NOTIFICATION-TYPE OBJECTS { alarmSeverity, alarmState, ifAlias } STATUS current DESCRIPTION "This trap is sent upon a change in Remote connectivity of Bundle connection." ::= { radSysWanEvents 14 } bundleConnectionStatusTrap NOTIFICATION-TYPE OBJECTS { ifAlias, ip2IfOperStatus } STATUS current DESCRIPTION "This trap is sent upon any change in the connectivity status of a Bundle (ip2IfOperStatus). The ifAlias index is the ifIndex of the bundle that its status has been changed." ::= { radSysWanEvents 15 } -- -- file :v:\doc\rdv\mib\ver470\bdband.txt -- END RAD-BROADBAND-IF-MIB DEFINITIONS ::= BEGIN --Version: 1.0 --Date: 14-Feb-2000 --By: Smadar Tauber --File: bdband.mib -- --Last update: 16-Jan-2001 by Liora Gafni broadbandIf OBJECT IDENTIFIER ::= {diverseIfWanGen 8} bdbandConfig OBJECT IDENTIFIER ::= {broadbandIf 1} prtPhyPerfHistory OBJECT IDENTIFIER ::= {broadbandIf 2} -- Indication Signal Table prtBdbandIndTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtBdbandIndEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Indication Signal table." ::= { bdbandConfig 1 } prtBdbandIndEntry OBJECT-TYPE SYNTAX PrtBdbandIndEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Indication Signal table." INDEX {prtBdbandCnfgIdx, prtBdbandIdx, prtBdbandIndSig, prtBdbandIndEvent} ::= { prtBdbandIndTable 1 } PrtBdbandIndEntry ::= SEQUENCE { prtBdbandCnfgIdx Integer32, prtBdbandIdx Integer32, prtBdbandIndSig INTEGER, prtBdbandIndEvent INTEGER, prtBdbandIndSigEnable INTEGER, prtBdbandRowStatus RowStatus } prtBdbandCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Idx of the Agent Cnfg the following objects refer. 255=Temporary Cnfg (when relevant, Set is done only to this configuration). For Agents that support only one configuration, this object will be constant=1. " ::= { prtBdbandIndEntry 1 } prtBdbandIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a unique port or interface number. For numbering, see product's spec. For some products, the numbering can equal ifIndex." ::= { prtBdbandIndEntry 2 } prtBdbandIndSig OBJECT-TYPE SYNTAX INTEGER { ais (1), rdi (2), aisAndRdi (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a unique Indication Signal. ais(1) = AIS = Alarm Indication Signal. rdi(2) = RDI = Remote Defect Indication." ::= { prtBdbandIndEntry 3 } prtBdbandIndEvent OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), slm (2), fail (3), eed (4), pathTrace (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a unique Event that can cause the Indication Signal. slm(2) = SLM = Signal Label Mismatch eed(4) = EED = Excessive Error Defect pathTrace(5) = the end-to-end source/destination of information is wrong." ::= { prtBdbandIndEntry 4 } prtBdbandIndSigEnable OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), disable (2), enable (3) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object allows user to define if the event specified by prtBdbandIndEvent will cause creation of the Indication Signal specified by prtBdbandIndSig or not. disable - will not enable causing the signal enable - will enable causing the signal. " ::= { prtBdbandIndEntry 5 } prtBdbandRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Creation/Deletion of rows in the table." ::= { prtBdbandIndEntry 6 } -- Port Phy Config Table prtPhyConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtPhyConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Phy Config table. Used now for Phy25.6 Mbps." ::= { bdbandConfig 2 } prtPhyConfigEntry OBJECT-TYPE SYNTAX PrtPhyConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Phy Config table. " INDEX { ifIndex } ::= { prtPhyConfigTable 1 } PrtPhyConfigEntry ::= SEQUENCE { prtPhyTimeElapsed Integer32, prtPhyValidIntervals Integer32 } prtPhyTimeElapsed OBJECT-TYPE SYNTAX Integer32 (0..899) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of seconds that have elapsed since the beginning of the current error-measurement period." ::= { prtPhyConfigEntry 1 } prtPhyValidIntervals OBJECT-TYPE SYNTAX Integer32 (0..96) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of previous intervals for which valid data was collected. The value will be 96 unless the interface was brought online within the last 24 hours, in which case the value will be the number of complete 15 minute since the interface has been online." ::= { prtPhyConfigEntry 2 } --Phy Performance History Tables -- The PHY Current table contains various statistics being -- collected for the current 15 minute interval. prtPhyCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtPhyCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The 25.6 Mbps Section/Line Current table." ::= { prtPhyPerfHistory 1 } prtPhyCurrentEntry OBJECT-TYPE SYNTAX PrtPhyCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the 25.6 Mbps Line Current table. ifIndex of the line 25.6 Mbps layer of type 25.6 Mbps." INDEX { ifIndex } ::= { prtPhyCurrentTable 1 } PrtPhyCurrentEntry ::= SEQUENCE { prtPhyCurrentLOS Gauge32, prtPhyCurrentLSV Gauge32, prtPhyCurrentUAS Gauge32, prtPhyCurrentSES Gauge32, prtPhyCurrentES Gauge32, prtPhyCurrentStatus OCTET STRING, prtPhyCurrentLOF Gauge32 } prtPhyCurrentLOS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Loss Of Sync seconds, encountered by a 25.6 Mbps interface in the current 15 minute interval." ::= { prtPhyCurrentEntry 1 } prtPhyCurrentLSV OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Line symbol violation seconds, encountered by a 25.6 Mbps interface in the current 15 minute interval." ::= { prtPhyCurrentEntry 2 } prtPhyCurrentUAS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of UAS encountered by a 25.6 Mbps interface in the current 15 minute interval." ::= { prtPhyCurrentEntry 3 } prtPhyCurrentSES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of SES encountered by a 25.6 Mbps interface in the current 15 minute interval." ::= { prtPhyCurrentEntry 4 } prtPhyCurrentES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Errored Seconds, encountered by a 25.6 Mbps interface in the current 15 minute interval." ::= { prtPhyCurrentEntry 5 } prtPhyCurrentStatus OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) MAX-ACCESS read-only STATUS current DESCRIPTION "The statuses of the current interval: 0 - O.K. 1 - The link has been switched by a redundancy mechanism. 2 - Module is in/out. 4 - Empty - card is out." ::= { prtPhyCurrentEntry 6 } prtPhyCurrentLOF OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Loss of Frames, encountered by an interface in the current 15 minute interval." ::= { prtPhyCurrentEntry 7 } -- The PHY interface Interval -- The PHY Interval Table contains various statistics -- collected by the Interface over the previous 24 -- hours of operation. The past 24 hours are broken into 96 -- completed 15 minute intervals. prtPhyIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtPhyIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Line Interval table." ::= { prtPhyPerfHistory 2 } prtPhyIntervalEntry OBJECT-TYPE SYNTAX PrtPhyIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the 25.6 Mbps Line Interval table. ifIndex of the line 25.6 Mbps layer of type 25.6 Mbps." INDEX { ifIndex, prtPhyIntervalNumber } ::= { prtPhyIntervalTable 1 } PrtPhyIntervalEntry ::= SEQUENCE { prtPhyIntervalNumber Integer32, prtPhyIntervalLOS Gauge32, prtPhyIntervalLSV Gauge32, prtPhyIntervalUAS Gauge32, prtPhyIntervalSES Gauge32, prtPhyIntervalES Gauge32, prtPhyIntervalStatus OCTET STRING, prtPhyIntervalLOF Gauge32 } prtPhyIntervalNumber OBJECT-TYPE SYNTAX Integer32 (1..96) MAX-ACCESS read-only STATUS current DESCRIPTION "A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid)." ::= { prtPhyIntervalEntry 1 } prtPhyIntervalLOS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Loss Of Sync seconds , encountered by a 25.6 Mbps interface in one of the previous 96, individual 15 minute intervals." ::= { prtPhyIntervalEntry 2 } prtPhyIntervalLSV OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of line symbol violation seconds , encountered by a 25.6 Mbps interface in one of the previous 96, individual 15 minute intervals." ::= { prtPhyIntervalEntry 3 } prtPhyIntervalUAS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of UAS encountered by a 25.6 Mbps interface in one of the previous 96, individual 15 minute intervals." ::= { prtPhyIntervalEntry 4 } prtPhyIntervalSES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of SES encountered by a 25.6 Mbps interface in one of the previous 96, individual 15 minute intervals." ::= { prtPhyIntervalEntry 5 } prtPhyIntervalES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Errored Seconds, encountered by a 25.6 Mbps interface in one of the previous 96, individual 15 minute intervals." ::= { prtPhyIntervalEntry 6 } prtPhyIntervalStatus OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) MAX-ACCESS read-only STATUS current DESCRIPTION " The statuses of the current interval: 0 - O.K. 1 - The link has been switched by a redundancy mechanism. 2 - Module is in/out. 4 - Empty - card is out." ::= { prtPhyIntervalEntry 7 } prtPhyIntervalLOF OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Loss of Frames, encountered by an interface in one of the previous 96, individual 15 minute intervals." ::= { prtPhyIntervalEntry 8 } END -- -- file :v:\doc\rdv\mib\ver465\r2.txt -- --Title: RAD's WAN R2 Interface MIB --By: Smadar Tauber --Date : 18.04.2000 --Last Update: 24-Jul-00 --By: Smadar Tauber --File: v:\doc\rdv\mib\ver465\r2.txt --wanGen OBJECT IDENTIFIER ::= {radWan 1} --diverseIfWanGen OBJECT IDENTIFIER ::= {wanGen 6} (see mpmx.txt) r2If OBJECT IDENTIFIER ::= {diverseIfWanGen 9} r2ProfileCnfg OBJECT IDENTIFIER ::= {r2If 1} r2IfStatus OBJECT IDENTIFIER ::= {r2If 2} --R2 Profile Configuration tables -- --Only the profiles that are defined having agnSigProfType=r2Cas will --exist in these tables. --The parameters of the r2CnfgTable are defined per configuration, per Country (RW). r2CnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF R2CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= { r2ProfileCnfg 1} r2CnfgEntry OBJECT-TYPE SYNTAX R2CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {r2CnfgIdx, r2CnfgProfileIdx} ::= { r2CnfgTable 1} R2CnfgEntry ::= SEQUENCE { r2CnfgIdx Integer32, r2CnfgProfileIdx Integer32, r2Mode INTEGER, r2Country Integer32, r2Delay INTEGER, r2MeteringInd INTEGER, r2BreakMakeRatio INTEGER, r2ReleaseGuardT2 Integer32, r2Regret Integer32, r2SeizeDetect Integer32, r2SeizeAckDelay Integer32, r2ClearBackDetect Integer32, r2ClearFwdDetect Integer32, r2FaultDetect Integer32, r2FaultRemoveDetect Integer32, r2MeterPulseDuration Integer32, r2SeizeAckWait Integer32, r2SeizeAckDetect Integer32, r2AnswerDetect Integer32, r2BlockRemoveDetect Integer32, r2MeterPulseDetect Integer32, r2ForcedDisconnect Integer32, r2DisconnectAck Integer32, r2ReleaseGuardT1 Integer32, r2CnfgRowStatus RowStatus } r2CnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg being accessed. 255 = TmpCnfg. 1 = Current Cnfg. Write is allowed only to TmpCnfg." ::= {r2CnfgEntry 1} r2CnfgProfileIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Profile Index. Valid values: 1..5 Only instances of profiles that are defined having agnSigProfType=r2Cas will exist in this table." ::= {r2CnfgEntry 2} r2Mode OBJECT-TYPE SYNTAX INTEGER { auto (2), manual(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "R2 Mode. auto - in this mode, default value of timers will be used by R2, according to the selected r2Country. manual - in this mode, user can change the value of R2 timers within the valid limits, specific to each country." ::= {r2CnfgEntry 3} r2Country OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "R2 Country. R2 Timers can have different range of values and defaults for each country. When r2Mode=auto, the default value is used by R2 according to this selected country. 1=ITU-T (standard values) 2=Korea 3=India 4=Brasil (continuous) 5=Brasil (pulsed) 6..10 - reserved for future countries." ::= {r2CnfgEntry 4} r2Delay OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), terrestrial (2), satellite (3) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object enables user to configure the link as satellite or terrestrial. The seize acknowledge detect timing is much shorter (msec) for terrestrial link than for satellite link (1-2 sec)." ::= {r2CnfgEntry 5} r2MeteringInd OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), cBit (2), bBit (3) } MAX-ACCESS read-create STATUS current DESCRIPTION "Which Bit will be used for Metering Indication." ::= {r2CnfgEntry 6} r2BreakMakeRatio OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), break56Make44(2), break64Make36(3), break80Make20(4) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object describes the Break-Make Ratio of Pulse Duration, in [msec]. RW only when r2Mode=manual." ::= {r2CnfgEntry 7} r2ReleaseGuardT2 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Release Guard timing T2. Release guard timing before going to idle, in [msec]. RW only when r2Mode=manual." ::= {r2CnfgEntry 8} r2Regret OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Regret duration, in [sec]. RW only when r2Mode=manual." ::= {r2CnfgEntry 9} r2SeizeDetect OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Seize Detect. Timer of the R2 incoming side. Minimum duration to detect a valid seizure, in [msec]. RW only when r2Mode=manual." ::= {r2CnfgEntry 10} r2SeizeAckDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Timer of the R2 incoming side. Delay before sending a valid seize ack signal, in [msec]. Applicable only when r2Mode=manual. only when r2Mode=manual." ::= {r2CnfgEntry 11} r2ClearBackDetect OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Timer of the R2 incoming side. Minimum duration to recognize a valid clear-back, in [msec]. RW only when r2Mode=manual." ::= {r2CnfgEntry 12} r2ClearFwdDetect OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Timer of the R2 incoming side. Minimum duration to recognize a valid clear-forward, in [msec]. RW only when r2Mode=manual." ::= {r2CnfgEntry 13} r2FaultDetect OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Timer of the R2 incoming side. Minimum duration to recognize a block signal, in [msec]. RW only when r2Mode=manual." ::= {r2CnfgEntry 14} r2FaultRemoveDetect OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Timer of the R2 incoming side. Minimum duration to recognize a valid block removal signal, in [msec]. RW only when r2Mode=manual." ::= {r2CnfgEntry 15} r2MeterPulseDuration OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Timer of the R2 incoming side. Duration of metering pulse to be sent, in [msec]. RW only when r2Mode=manual." ::= {r2CnfgEntry 16} r2SeizeAckWait OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Timer of the R2 outgoing side. Minimum duration to receive seizure acknowledge signal, in [msec]. RW only when r2Mode=manual." ::= {r2CnfgEntry 17} r2SeizeAckDetect OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Timer of the R2 outgoing side. Minimum duration to recognize a valid seizure acknowledge signal, in [msec]. RW only when r2Mode=manual." ::= {r2CnfgEntry 18} r2AnswerDetect OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Timer of the R2 outgoing side. Minimum duration to recognize a valid answer signal, in [msec]. RW only when r2Mode=manual." ::= {r2CnfgEntry 19} r2BlockRemoveDetect OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Timer of the R2 outgoing side. Minimum duration to recognize a valid block removal signal, in [msec]. RW only when r2Mode=manual." ::= {r2CnfgEntry 20} r2MeterPulseDetect OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Timer of the R2 outgoing side. Minimum duration of incoming meter pulse, in [msec]. RW only when r2Mode=manual." ::= {r2CnfgEntry 21} r2ForcedDisconnect OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Timer of the R2 outgoing side. Minimum duration to recognize disconnect signal, in [msec]. RW only when r2Mode=manual." ::= {r2CnfgEntry 22} r2DisconnectAck OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Timer of the R2 outgoing side. Minimum duration to recognize disconnect acknowledge signal, in [msec]. RW only when r2Mode=manual." ::= {r2CnfgEntry 23} r2ReleaseGuardT1 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Timer of the R2 outgoing side. Minimum duration to release guard, in [msec]. During this time, no new call can be initiated. RW only when r2Mode=manual." ::= {r2CnfgEntry 24} r2CnfgRowStatus OBJECT-TYPE SYNTAX RowStatus --active(1), --destroy(6) MAX-ACCESS read-create STATUS current DESCRIPTION "This object enables the user to add/delete entries to/from the table." ::= {r2CnfgEntry 25} --The configuration parameters of the r2TsTable are defined per configuration, --per Country, per TS (RW Table). r2TsTable OBJECT-TYPE SYNTAX SEQUENCE OF R2TsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= { r2ProfileCnfg 2} r2TsEntry OBJECT-TYPE SYNTAX R2TsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {r2TsCnfgIdx, r2TsProfileIdx, r2TsIdx} ::= { r2TsTable 1} R2TsEntry ::= SEQUENCE { r2TsCnfgIdx Integer32, r2TsProfileIdx Integer32, r2TsIdx Integer32, r2TsCallEnable INTEGER, r2TsMetering INTEGER, r2TsRowStatus RowStatus } r2TsCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg being accessed. 255 = TmpCnfg. 1 = Current Cnfg. Write is allowed only to TmpCnfg." ::= {r2TsEntry 1} r2TsProfileIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Profile Index. Valid values: 1..5 Only instances of profiles that are defined having agnSigProfType=r2Cas will exist in this table." ::= {r2TsEntry 2} r2TsIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "TS Index. Valid values: 1..31" ::= {r2TsEntry 3} r2TsCallEnable OBJECT-TYPE SYNTAX INTEGER { incoming (2), outgoing (3), both (4) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the Enabled Call direction for the specific TS." ::= {r2TsEntry 4} r2TsMetering OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates if the specific TS should support Metering." ::= {r2TsEntry 5} r2TsRowStatus OBJECT-TYPE SYNTAX RowStatus --active(1), --destroy(6) MAX-ACCESS read-create STATUS current DESCRIPTION "This object enables the user to add/delete entries to/from the table." ::= {r2TsEntry 6} --R2 Status table (RO) - TS Level, per Link -- --The table is applicable only for E1 Links having an R2 Profile. r2StatusTable OBJECT-TYPE SYNTAX SEQUENCE OF R2StatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= { r2IfStatus 1} r2StatusEntry OBJECT-TYPE SYNTAX R2StatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {r2StatusSlotIdx, r2StatusPortIdx, r2StatusTsIdx} ::= { r2StatusTable 1} R2StatusEntry ::= SEQUENCE { r2StatusSlotIdx INTEGER, r2StatusPortIdx Integer32, r2StatusTsIdx Integer32, r2StatusSigDirection INTEGER, r2StatusTsState INTEGER, r2StatusProtocolState INTEGER } r2StatusSlotIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Slot Index" ::= {r2StatusEntry 1} r2StatusPortIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a unique port number of the ML having R2 interface. Valid values: exPrt1 (1)..exPrt4 (4)" ::= {r2StatusEntry 2} r2StatusTsIdx OBJECT-TYPE SYNTAX Integer32 (1..31) MAX-ACCESS read-only STATUS current DESCRIPTION "Time Slot index." ::= {r2StatusEntry 3} r2StatusSigDirection OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), incoming (2), outgoing (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "R2 Time Slot Signaling Direction." ::= {r2StatusEntry 4} r2StatusTsState OBJECT-TYPE SYNTAX INTEGER { notUsed (1), normal (2), remoteBlocked (3), localBlocked (4), localLoop (5), remoteLoop (6) } MAX-ACCESS read-only STATUS current DESCRIPTION "R2 TS State" ::= {r2StatusEntry 5} r2StatusProtocolState OBJECT-TYPE SYNTAX INTEGER { idle (1), seized (2), seizureAcknowledged (3), answered (4), clearForward (5), clearBack (6), blocked (7), forcedDisc (8), doubleSeizure (9), fault (10), discAcknowledged (11), fault1 (12), fault6 (13), fault3 (14) } MAX-ACCESS read-only STATUS current DESCRIPTION "R2 Protocol State." ::= {r2StatusEntry 6} -- -- file :v:\doc\rdv\mib\ver485\atm\layer2.txt -- -- -- file: v:\doc\rdv\mib\ver485\atm\layer2.txt -- --RTR-MIB -- --Last update: 09-Jan-2002 --By: Ilana Schvetz -- ************************************************ -- Link Layer (layer 2) MIB -- ************************************************ atmLayer2 OBJECT IDENTIFIER ::= {radAtm 7} atmLayer2XVclTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmLayer2XVclEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is an extension of VCL table, which is created for each LAN VCC." ::= { atmLayer2 1 } atmLayer2XVclEntry OBJECT-TYPE SYNTAX AtmLayer2XVclEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Conceptual row in atmVclTable. This table augments the RFC2515 VCL table." AUGMENTS { atmVclEntry } ::= { atmLayer2XVclTable 1 } AtmLayer2XVclEntry ::= SEQUENCE { atmLayer2XVclConnMode INTEGER, atmLayer2XVclGroupIdx Integer32 } atmLayer2XVclConnMode OBJECT-TYPE SYNTAX INTEGER { main (1), sub (2) } MAX-ACCESS read-create STATUS current DESCRIPTION "Each valid LAN VCC is either Main or Sub. This parameter is configured only once on creation of a LAN VCC. It can not be changed after creation. In order to change the Mode, user should delete the connection and create a new one. main - A LAN VCC, which holds its own bridge port. Bridge forwarding and Bridge learning is performed only on Main VCCs. For working on a transparent bridge, that doesn't perform layer 2 priority mapping, a Main VCC should be opened, which is the default connection Mode. When working with layer 2 priority, a group of LAN VCCs should be configured, where each group will be associated with only one Main VCC. A specific Main can not be used by more than one group. sub - A LAN VCC is not part of the bridging mechanism. A Sub VCC automatically inherit some general definitions from Main VCC of its group: ATM Slot/Port and LAN Slot/Port. Max number of Sub VCCs allowed per group is: [Number of Priorities - 1]." ::= { atmLayer2XVclEntry 1 } atmLayer2XVclGroupIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The group identifier. A VCC Group identifier = 0 if the VCC was not associated with a group yet. This value is updated according to the group identifier set by atmLayer2GroupTable." ::= { atmLayer2XVclEntry 2 } atmLayer2GroupTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmLayer2GroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains groups and their members. A group is a bundle of VCCs, which acts as different queues. Main and Sub VCCs should have the same ATM slot and port, and the same LAN slot and port. Each group contains: 1 to VCCs." ::= { atmLayer2 2 } atmLayer2GroupEntry OBJECT-TYPE SYNTAX AtmLayer2GroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Conceptual row in atmLayer2GroupTable. The indexes: ifIndex, atmVclVpi and atmVclVci indicate the Network ATM End-Point. Upon a group creation, one Main VCC must be added first. After the group was created, Sub VCCs may be added to the group." INDEX { atmLayer2GroupIdx, ifIndex, atmVclVpi, atmVclVci } ::= { atmLayer2GroupTable 1 } AtmLayer2GroupEntry ::= SEQUENCE { atmLayer2GroupIdx Integer32, atmLayer2GroupRowStatus RowStatus, atmLayer2GroupConnMode INTEGER, atmLayer2GroupConnPriority OCTET STRING, atmLayer2GroupName SnmpAdminString } atmLayer2GroupIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The group identifier. 0 is not a valid index." ::= { atmLayer2GroupEntry 1 } atmLayer2GroupRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Creation/Deletion of rows in the table, and indication of the entry's status." ::= {atmLayer2GroupEntry 2 } atmLayer2GroupConnMode OBJECT-TYPE SYNTAX INTEGER { main (1), sub (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Each valid LAN VCC is either Main or Sub as configured in atmLayer2XVclTable." ::= { atmLayer2GroupEntry 3 } atmLayer2GroupConnPriority OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1)) MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter is configured by atmLayer2PriorityRx from atmLayer2PriorityTable. Each bit in the Octet represents a specific priority as follows: MSB 7 6 5 4 3 2 1 0 LSB -> Priorities |____________________| 1 0 0 1 0 0 0 1 -> Value In this example, a certain VCC has several priorities: 0, 4 and 7." ::= { atmLayer2GroupEntry 4 } atmLayer2GroupName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (1..32)) MAX-ACCESS read-create STATUS current DESCRIPTION "Group name. Configured by the user. The name is unique per system. For atmLayer2GroupIdx=0, the name will be null." ::= { atmLayer2GroupEntry 5 } atmLayer2PriorityTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmLayer2PriorityEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table maps all priorities inside a group. Several priorities might be mapped to the same VCC. Upon priority change, the agent will update the VCCs of the changed priority in this table, and will update - atmLayer2GroupConnPriority parameter of both former and new owners of the changed priority. Changing a VCC value is actually a change of three parameters simultaneously: atmLayer2PriorityIfIndex, atmLayer2PriorityVclVpi and atmLayer2PriorityVclVci. Otherwise, the set will be rejected, since there might be that such VCC doesn't exist in the specific group." ::= { atmLayer2 3 } atmLayer2PriorityEntry OBJECT-TYPE SYNTAX AtmLayer2PriorityEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Conceptual row in atmLayer2PriorityTable. Each entry is a Network ATM End-Point per priority. Upon a group creation, all priorities are mapped to the Main VCC. Number of entries per group is according to the number of priorities enabled. (For example, for Max priorities = 8, the agent will create 8 entries)." INDEX { atmLayer2PriorityGroupIdx, atmLayer2PriorityRx } ::= { atmLayer2PriorityTable 1 } AtmLayer2PriorityEntry ::= SEQUENCE { atmLayer2PriorityGroupIdx Integer32, atmLayer2PriorityRx INTEGER, atmLayer2PriorityIfIndex InterfaceIndex, atmLayer2PriorityVclVpi Integer32, atmLayer2PriorityVclVci Integer32 } atmLayer2PriorityGroupIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The group identifier." ::= { atmLayer2PriorityEntry 1 } atmLayer2PriorityRx OBJECT-TYPE SYNTAX INTEGER (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "The priority values. The used values are 0-7, but since this value is part of the index of the table, and in order to avoid '0' as an index, the index syntax is 1..8, but the real value is atmLayer2PriorityRx-1: 0 - for Low priority. 7 - for High priority." ::= { atmLayer2PriorityEntry 2 } atmLayer2PriorityIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-create STATUS current DESCRIPTION "ATM ifIndex of the network End-Point." ::= { atmLayer2PriorityEntry 3 } atmLayer2PriorityVclVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Vpi of the network End-Point." ::= { atmLayer2PriorityEntry 4 } atmLayer2PriorityVclVci OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Vci of the network End-Point." ::= { atmLayer2PriorityEntry 5 } atmLayer2GroupIndexNext OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains an appropriate value to be used for atmLayer2GroupIdx when creating entries in the atmLayer2GroupTable. The value 0 indicates that no unassigned entries are available. To obtain the atmLayer2GroupIdx value for a new entry, the manager gets the current value of this object. The next index will be of the first unassigned entry. It will be provided by checking the assigned entries." ::= { atmLayer2 4 } --VLAN atmLayer2CfgTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmLayer2CfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Bridge configuration Table. This table supports multi-bridge and bridge features within an ATM device." ::= { atmLayer2 5 } atmLayer2CfgEntry OBJECT-TYPE SYNTAX AtmLayer2CfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Conceptual row in atmLayer2CfgTable. Each entry in this table contains the bridging attributes for both Ethernet and ATM sides. The interface index is the Ethernet port interface." INDEX { ifIndex } ::= { atmLayer2CfgTable 1 } AtmLayer2CfgEntry ::= SEQUENCE { atmLayer2CfgBridgingMode INTEGER, atmLayer2CfgVlanMode INTEGER, atmLayer2CfgAtmAcceptableFrameType INTEGER, atmLayer2CfgAtmIngressFiltering TruthValue, atmLayer2CfgAtmTxFrameType INTEGER, atmLayer2CfgEthAcceptableFrameType INTEGER, atmLayer2CfgBridgeAction INTEGER, atmLayer2CfgLearningMode INTEGER } atmLayer2CfgBridgingMode OBJECT-TYPE SYNTAX INTEGER { accessOnly(1), accessAndSwitching (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Bridging mode can be one of the following: ATM <> Ethernet - Bridging is between the Ethernet port and the ATM port (there is no bridging between VCs). ATM <> Ethernet + ATM - Bridging is done both between the Ethernet port and the ATM port and also between VCs." ::= { atmLayer2CfgEntry 1 } atmLayer2CfgVlanMode OBJECT-TYPE SYNTAX INTEGER { disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "VLAN Mode. Upon Mode changing, all LAN VCCs will be deleted by the agent from all tables that include LAN VCCs." ::= { atmLayer2CfgEntry 2 } atmLayer2CfgAtmAcceptableFrameType OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), admitAll (2), admitOnlyVlanTagged (3), admitOnlyUnTagged (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The Frame Type that will be acceptable by the VCCs that are associated with this Ethernet port. Frames which don't match the selected type will be discarded. admitAll - all frames will be accepted. admitOnlyVlanTagged - only Tagged frames will be accepted. admitOnlyUnTagged - only unTagged frames will be accepted." ::= { atmLayer2CfgEntry 3 } atmLayer2CfgAtmIngressFiltering OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "For the VCCs that are associated with this Ethernet port, when this is true(1) the device will discard incoming frames for VLANs which do not include this Port in its Member set. When false(2), the port will accept all incoming frames." ::= { atmLayer2CfgEntry 4 } atmLayer2CfgAtmTxFrameType OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), unTagged (2), tagged (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The Frame Type that will be transmitted by the VCCs that are associated with this Ethernet port. unTagged - The transmitted frames will be unTagged. tagged - The transmitted frames will be Tagged." ::= { atmLayer2CfgEntry 5 } atmLayer2CfgEthAcceptableFrameType OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), admitAll (2), admitOnlyVlanTagged (3), admitOnlyUnTagged (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The Frame Type that this Ethernet port will accept. This parameter is notApplicable for atmLayer2VlanMode=disable. Frames which don't match the selected type will be discarded. admitAll - all frames will be accepted. admitOnlyVlanTagged - only Tagged frames will be accepted. admitOnlyUnTagged - only unTagged frames will be accepted." ::= { atmLayer2CfgEntry 6 } atmLayer2CfgBridgeAction OBJECT-TYPE SYNTAX INTEGER { deleteLanTable (7), noOp (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object enables to perform the specified action on the selected port." ::= { atmLayer2CfgEntry 7 } atmLayer2CfgLearningMode OBJECT-TYPE SYNTAX INTEGER { svl (1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the mode of the learning process of a bridge. svl - Shared VLAN process. If an individual MAC Address is learned in one VLAN, this information is used in forwarding decisions taken for that address for all other VLANs." ::= { atmLayer2CfgEntry 8 } -- -- file :v:\doc\rdv\mib\ver470\atm\fratm.txt -- -- -- file: v:\doc\rdv\mib\ver470\atm\frAtm.txt -- --FR-ATM-IWF-X-MIB -- --Last update: 28-Feb-2001 --By: Ilana Schvetz --atmSuPortFr OBJECT IDENTIFIER ::= { atmSuPort 4 } radAtmFr OBJECT IDENTIFIER ::= {radAtm 8} frAtmIwfXConnectionTable OBJECT-TYPE SYNTAX SEQUENCE OF FrAtmIwfXConnectionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is an extension of frAtmIwfXConnectionTable from RFC2955." ::= { radAtmFr 1 } frAtmIwfXConnectionEntry OBJECT-TYPE SYNTAX FrAtmIwfXConnectionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Conceptual row in frAtmIwfXConnectionTable. This table augments the RFC2955." AUGMENTS { frAtmIwfConnectionEntry } ::= { frAtmIwfXConnectionTable 1 } FrAtmIwfXConnectionEntry ::= SEQUENCE { frAtmIwfXConnMode INTEGER, frAtmIwfXConnSscsDlci Integer32 } frAtmIwfXConnMode OBJECT-TYPE SYNTAX INTEGER { service(1), network(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "FR IWF Mode. service - Service InterWorking (FRF.8), network - Network InterWorking (FRF.5)." ::= { frAtmIwfXConnectionEntry 1 } frAtmIwfXConnSscsDlci OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "This parameter is relevant for frAtmIwfXConnMode=network (FRF.5) only. This parameter allow configuration of the FR SSCS DLCI that is transferred to the remote FR unit." ::= { frAtmIwfXConnectionEntry 2 } END -- -- file :v:\doc\rdv\mib\ver485\atm\radaal5.txt -- -- -- file :v:\doc\rdv\mib\ver485\atm\radaal5.txt -- --Last update: 20-Jan-2002 by Ilana Schvetz ATM-X-MIB DEFINITIONS ::= BEGIN -- --atmGen OBJECT IDENTIFIER ::= {radAtm 2} --atmPerfHistory OBJECT IDENTIFIER ::= {atmGen 1} --atmIfPerformance OBJECT IDENTIFIER ::= {atmPerfHistory 1} -- AAL5 Virtual Channel Connection Performance Statistics -- Table -- This table contains the AAL5 extension -- performance statistics of a VCC at the -- interface associated with an AAL5 entity in an ATM -- host or ATM switch. aal5VccXTable OBJECT-TYPE SYNTAX SEQUENCE OF Aal5VccXEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is an extension to AAL5 VCC Table." ::= { atmIfPerformance 4 } aal5VccXEntry OBJECT-TYPE SYNTAX Aal5VccXEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This list contains the additional AAL5 VCC performance parameters and is indexed by ifIndex values of AAL5 interfaces and the associated VPI/VCI values." AUGMENTS { aal5VccEntry } ::= { aal5VccXTable 1 } Aal5VccXEntry ::= SEQUENCE { aal5VccInFrames Counter32, aal5VccOutFrames Counter32, aal5VccUnknownProtocolFrames Counter32 } aal5VccInFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames received via this interface." ::= { aal5VccXEntry 1 } aal5VccOutFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of frames transmitted out of the interface." ::= { aal5VccXEntry 2 } aal5VccUnknownProtocolFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames that were discarded due to unsupported protocol encapsulation on this VCC." ::= { aal5VccXEntry 3 } aal5VccCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF Aal5VccCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The AAL5 Current table." ::= { atmIfPerformance 5 } aal5VccCurrentEntry OBJECT-TYPE SYNTAX Aal5VccCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the AAL5 Current table." INDEX { ifIndex, aal5VccVpi, aal5VccVci } ::= { aal5VccCurrentTable 1 } Aal5VccCurrentEntry ::= SEQUENCE { aal5VccCurrentInFrames Gauge32, aal5VccCurrentOutFrames Gauge32, aal5VccCurrentUnknownProtocolFrames Gauge32, aal5VccCurrentCrcErrors Gauge32, aal5VccCurrentLengthError Gauge32 } aal5VccCurrentInFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received frames, encountered by the AAL5 interface in the current 15 minute interval." ::= { aal5VccCurrentEntry 1 } aal5VccCurrentOutFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted frames, encountered by the AAL5 interface in the current 15 minute interval." ::= { aal5VccCurrentEntry 2 } aal5VccCurrentUnknownProtocolFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of frames that were discarded due to unsupported protocol encapsulation, encountered by the AAL5 interface in the current 15 minute interval." ::= { aal5VccCurrentEntry 3 } aal5VccCurrentCrcErrors OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of AAL5 CPCS PDUs received with CRC-32 errors, encountered by the AAL5 interface in the current 15 minute interval." ::= { aal5VccCurrentEntry 4 } aal5VccCurrentLengthError OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received frames with length error, encountered by the AAL5 interface in the current 15 minute interval." ::= { aal5VccCurrentEntry 5 } -- Interval Table aal5VccIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF Aal5VccIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The AAL5 Interval table." ::= { atmIfPerformance 6 } aal5VccIntervalEntry OBJECT-TYPE SYNTAX Aal5VccIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the AAL5 Interval table." INDEX { ifIndex, aal5VccVpi, aal5VccVci, aal5VccIntervalNumber } ::= { aal5VccIntervalTable 1 } Aal5VccIntervalEntry ::= SEQUENCE { aal5VccIntervalNumber Integer32, aal5VccIntervalInFrames Gauge32, aal5VccIntervalOutFrames Gauge32, aal5VccIntervalUnknownProtocolFrames Gauge32, aal5VccIntervalCrcErrors Gauge32, aal5VccIntervalLengthError Gauge32 } aal5VccIntervalNumber OBJECT-TYPE SYNTAX Integer32 (1..96) MAX-ACCESS read-only STATUS current DESCRIPTION "A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals exist)." ::= { aal5VccIntervalEntry 1 } aal5VccIntervalInFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received frames, encountered by the AAL5 interface in one of the previous 96, individual 15 minute, intervals." ::= { aal5VccIntervalEntry 2 } aal5VccIntervalOutFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted frames, encountered by the AAL5 interface in in one of the previous 96, individual 15 minute, intervals." ::= { aal5VccIntervalEntry 3 } aal5VccIntervalUnknownProtocolFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of frames that were discarded due to unsupported protocol encapsulation, encountered by the AAL5 interface in one of the previous 96, individual 15 minute, intervals." ::= { aal5VccIntervalEntry 4 } aal5VccIntervalCrcErrors OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of AAL5 CPCS PDUs received with CRC-32 errors, encountered by the AAL5 interface in one of the previous 96, individual 15 minute, intervals." ::= { aal5VccIntervalEntry 5 } aal5VccIntervalLengthError OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received frames with length error, encountered by the AAL5 interface in one of the previous 96, individual 15 minute, intervals." ::= { aal5VccIntervalEntry 6 } END -- -- file :v:\doc\rdv\mib\ver485\atm\atmCes.txt -- -- -- File: v:\doc\rdv\mib\ver485\atm\atmCes.txt -- Date: 17/01/02 -- By: Ilana Schvetz -- Last Update: 17-Jan-02 By Ilana Schvetz -- -- AAL1 statistics. An addition to ATMF-CES (ces.mib) -- atmCes OBJECT IDENTIFIER ::= {radAtm 9} atmCesPerformance OBJECT IDENTIFIER ::= {atmCes 1 } atmCesAal1CurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmCesAal1CurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The AAL1 Current table." ::= { atmCesPerformance 1 } atmCesAal1CurrentEntry OBJECT-TYPE SYNTAX AtmCesAal1CurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the AAL1 Current table." INDEX { atmCesAal1CurrentIfIndex } ::= { atmCesAal1CurrentTable 1 } AtmCesAal1CurrentEntry ::= SEQUENCE { atmCesAal1CurrentIfIndex Integer32, atmCesAal1CurrentSeqErrors Gauge32, atmCesAal1CurrentHdrErrors Gauge32, atmCesAal1CurrentPointerReframes Gauge32, atmCesAal1CurrentBufUnderflows Gauge32, atmCesAal1CurrentBufOverflows Gauge32 } atmCesAal1CurrentIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the AAL1 interface. It may be ifIndex." ::= { atmCesAal1CurrentEntry 1 } atmCesAal1CurrentSeqErrors OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Discarded cells due to wrong sequence number, encountered by an AAL1 interface in the current 15 minute interval." ::= { atmCesAal1CurrentEntry 2 } atmCesAal1CurrentHdrErrors OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Discarded cells due to bad AAL1 header error (including correctable and uncorrectable CRC, and bad parity), encountered by an AAL1 interface in the current 15 minute interval." ::= { atmCesAal1CurrentEntry 3 } atmCesAal1CurrentPointerReframes OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of events in which a SDT pointer isn't where it is expected to be, and must be reacquired, encountered by an AAL1 interface in the current 15 minute interval." ::= { atmCesAal1CurrentEntry 4 } atmCesAal1CurrentBufUnderflows OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of buffer underflow events, encountered by an AAL1 interface in the current 15 minute interval." ::= { atmCesAal1CurrentEntry 5 } atmCesAal1CurrentBufOverflows OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of buffer overflow events, encountered by an AAL1 interface in the current 15 minute interval." ::= { atmCesAal1CurrentEntry 6 } --Interval Table atmCesAal1IntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmCesAal1IntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The AAL1 Interval table." ::= { atmCesPerformance 2 } atmCesAal1IntervalEntry OBJECT-TYPE SYNTAX AtmCesAal1IntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the AAL1 Interval table." INDEX { atmCesAal1IntervalIfIndex, atmCesAal1IntervalNumber } ::= { atmCesAal1IntervalTable 1 } AtmCesAal1IntervalEntry ::= SEQUENCE { atmCesAal1IntervalIfIndex Integer32, atmCesAal1IntervalNumber Integer32, atmCesAal1IntervalSeqErrors Gauge32, atmCesAal1IntervalHdrErrors Gauge32, atmCesAal1IntervalPointerReframes Gauge32, atmCesAal1IntervalBufUnderflows Gauge32, atmCesAal1IntervalBufOverflows Gauge32 } atmCesAal1IntervalIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the AAL1 interface. It may be ifIndex." ::= { atmCesAal1IntervalEntry 1 } atmCesAal1IntervalNumber OBJECT-TYPE SYNTAX Integer32 (1..96) MAX-ACCESS read-only STATUS current DESCRIPTION "A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals exist)." ::= { atmCesAal1IntervalEntry 2 } atmCesAal1IntervalSeqErrors OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Discarded cells due to wrong sequence number, encountered by an AAL1 interface in one of the previous 96, individual 15 minute, intervals." ::= { atmCesAal1IntervalEntry 3 } atmCesAal1IntervalHdrErrors OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Discarded cells due to bad AAL1 header error (including correctable and uncorrectable CRC, plus bad parity), encountered by an AAL1 interface in one of the previous 96, individual 15 minute, intervals." ::= { atmCesAal1IntervalEntry 4 } atmCesAal1IntervalPointerReframes OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of events in which a SDT pointer isn't where it is expected to be, and must be reacquired, encountered by an AAL1 interface in one of the previous 96, individual 15 minute, intervals." ::= { atmCesAal1IntervalEntry 5 } atmCesAal1IntervalBufUnderflows OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of buffer underflow events, encountered by an AAL1 interface in one of the previous 96, individual 15 minute, intervals." ::= { atmCesAal1IntervalEntry 6 } atmCesAal1IntervalBufOverflows OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of buffer overflow events, encountered by an AAL1 interface in one of the previous 96, individual 15 minute, intervals." ::= { atmCesAal1IntervalEntry 7 } -- Extension for CES Configuration Table atmCesConfiguration OBJECT IDENTIFIER ::= {atmCes 2 } atmCesXConfTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmCesXConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is an extension of atmfCESConfTable table." ::= { atmCesConfiguration 1 } atmCesXConfEntry OBJECT-TYPE SYNTAX AtmCesXConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Conceptual row in atmfCESConfTable. A new row is created in this table upon each new CES VCC creation." AUGMENTS { atmfCESConfEntry } ::= { atmCesXConfTable 1 } AtmCesXConfEntry ::= SEQUENCE { atmCesXConfCBRMode INTEGER } atmCesXConfCBRMode OBJECT-TYPE SYNTAX INTEGER { normal (2), spaced (3) } MAX-ACCESS read-create STATUS current DESCRIPTION "This parameter defines if to use Spaced or Normal CBR. Normal - TD will be allocated from the policing range (described in ACE2002 NMS SRS). The PCR is expanded with a constant value of 30 cell/sec. Spaced - TD will be allocated from the spacing range (described in ACE2002 NMS SRS). The PCR and CDVT will be expanded as described for Normal, and the CES traffic including the OAM will be spaced out at the TD's PCR. This mode is used to prevent CDVT violation due to OAM cell insertion with the CES traffic." ::= { atmCesXConfEntry 1 } -- -- file :v:\doc\rdv\mib\ver475\radadsl.txt -- --Version: 1.0 --Date: 27.03.2001 --By: Yig'al Hachmon --File: ADSL.txt -- --Last Update: Yig'al Hachmon 8-July-2001 --ADSL configuration --wanGen OBJECT IDENTIFIER ::= {radWan 1} --diverseIfWanGen OBJECT IDENTIFIER ::= {wanGen 6} (see mpmx.txt) adslIf OBJECT IDENTIFIER ::= {diverseIfWanGen 10} adslConfTable OBJECT-TYPE SYNTAX SEQUENCE OF AdslConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of ADSL Configuration entries " ::= { adslIf 1 } adslConfEntry OBJECT-TYPE SYNTAX AdslConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in adslConfTable" INDEX { adslConfCnfgIdx,ifIndex } ::= { adslConfTable 1 } AdslConfEntry ::= SEQUENCE { adslConfCnfgIdx Integer32, adslConfFramingType INTEGER, adslConfPilotToneRequest INTEGER, adslConfTrellisCoding INTEGER, adslConfTransmissionMode INTEGER, adslConfStandardCompliance INTEGER, adslConfMaxBitPerBin Integer32, adslConfTxStartFreqBin Integer32, adslConfTxEndFreqBin Integer32, adslConfRxStartFreqBin Integer32, adslConfRxEndFreqBin Integer32, adslConfTxPowerAttenuation Integer32 } adslConfCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config. For products that support several configurations, Set can be performed only to the Temporary Config (=255). " ::= { adslConfEntry 1} adslConfFramingType OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), type2 (2), -- 64Kbits/S overhead type3 (3), -- 32Kbits/S overhead type0 (4), type1 (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "ADSL Frame type " ::= { adslConfEntry 2 } adslConfPilotToneRequest OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disable (2), -- PTR is disabled enable (3) -- PTR is enabled } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter controls Pilot Tone Request (PTR)." ::= { adslConfEntry 3} adslConfTrellisCoding OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disable (2), -- Trellis Coding disabled enable (3) -- Trellis Coding enabled } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter enables/disables Trellis error detection code. using error detection code may introduce delays." ::= { adslConfEntry 4 } adslConfTransmissionMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), echoCancellation (2), -- EC frequencyDivision(3) -- FDM } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter controls transmision mode: Echo Cancellation is required when both ATU-C an ATU-R use the same frequency. Frequency Division (different frequency ranges for ATU-C and ATU-R) may limit data rate." ::= { adslConfEntry 5} adslConfStandardCompliance OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), t1Hypen413 (2), -- T1-413 gDotDmt (3), -- G.DMT (Discrete Multi Tones) multiMode (4), -- Multimode alcatel1Dot4 (5), -- Alcatel 1.4 alcatel (6), -- Alcatel adi (7) -- ADI } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter indicates standard compliance G.Lite enables extended ADSL range, ease of installation, but requires lower rate." ::= { adslConfEntry 6} adslConfMaxBitPerBin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter indicates maximum number of bits per ADSL Bin. Each Bin has bandwidth of 4khz. Range of values for this parameter is 0..15 " ::= { adslConfEntry 7} adslConfTxStartFreqBin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter controls Transmit Start Bin number. For ADSL Annex A - range of values is 6 to 31. For ADSL Annex B - range of values is 33 to 63. Frequency (in khz unit) is calculated by multiplying this parameter value by bin bandwidth (4Khz) " ::= { adslConfEntry 8} adslConfTxEndFreqBin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter controls Transmit End Bin number. For ADSL Annex A - range of values is 6 to 31. For ADSL Annex B - range of values is 33 to 63. requency (in khz unit) is calculated by multiplying this value by bin bandwidth (4Khz) " ::= { adslConfEntry 9} adslConfRxStartFreqBin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter controls Receive Start Bin number. Range of values for this parameter depends on ADSL Annex supported, and transmisson mode (adslTransmissionMode) selected: ADSL Annex A and Echo Cancellation (EC) : 6 to 255 ADSL Annex A and Frequency Division (FDM) : 32 to 255 ADSL Annex B and Echo Cancellation (EC) : 33 to 255 ADSL Annex B and Frequency Division (FDM) : 64 to 255 Frequency (in khz unit) is calculated by multiplying this value by bin bandwidth (4Khz) " ::= { adslConfEntry 10} adslConfRxEndFreqBin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter controls Receive End Bin number. Range of values for this parameter depends on ADSL Annex supported, and transmisson mode (adslTransmissionMode) selected: ADSL Annex A and Echo Cancellation (EC) : 6 to 255 ADSL Annex A and Frequency Division (FDM) : 32 to 255 ADSL Annex B and Echo Cancellation (EC) : 33 to 255 ADSL Annex B and Frequency Division (FDM) : 64 to 255 Frequency (in khz unit) is calculated by multiplying this value by bin bandwidth (4Khz) " ::= { adslConfEntry 11} adslConfTxPowerAttenuation OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter controls Transmit Gain in dB units Range is 0 to 12dB. Resolution is 1 dB" ::= { adslConfEntry 12} adslStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF AdslStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of Adsl Status entries " ::= { adslIf 2 } adslStatusEntry OBJECT-TYPE SYNTAX AdslStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in adslStatusTable" INDEX { ifIndex } ::= { adslStatusTable 1 } AdslStatusEntry ::= SEQUENCE { adslStatusBitRxRate Gauge32 } adslStatusBitRxRate OBJECT-TYPE SYNTAX Gauge32 UNITS "bps" MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates actual Receive (Downstream) rate on this channel Range of values for this parameter is 0 -8,064,000 bps" ::= { adslStatusEntry 1} -- -- file :v:\doc\rdv\mib\ver475\radsdsl.txt -- --Version: 1.0 --Date: 27.03.2001 --By: Yig'al Hachmon --File: SDSL.txt -- --Last Update: Yig'al Hachmon 12-Apr-2001 --SDSL configuration --wanGen OBJECT IDENTIFIER ::= {radWan 1} --diverseIfWanGen OBJECT IDENTIFIER ::= {wanGen 6} (see mpmx.txt) sdslIf OBJECT IDENTIFIER ::= {diverseIfWanGen 11} sdslConfTable OBJECT-TYPE SYNTAX SEQUENCE OF SdslConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of SDSL Configuration entries " ::= { sdslIf 1 } sdslConfEntry OBJECT-TYPE SYNTAX SdslConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in sdslConfTable " INDEX {sdslConfCnfgIdx,ifIndex } ::= { sdslConfTable 1 } SdslConfEntry ::= SEQUENCE { sdslConfCnfgIdx Integer32, sdslConfRateAquisition INTEGER, sdslConfBaudRate INTEGER, sdslConfMode INTEGER } sdslConfCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config. For products that support several configurations, Set can be performed only to the Temporary Config (=255). " ::= { sdslConfEntry 1} sdslConfRateAquisition OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), autoNegotiate (2), fixed (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "SDSL Rate Aquisition mode Default value = fixed." ::= { sdslConfEntry 2 } sdslConfBaudRate OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), r144kbps (2), r748kbps (3), r1168kbps (4), r1550kbps (5), r2320kbps (6) } MAX-ACCESS read-write STATUS current DESCRIPTION "SDSL baud rate. Not applicable if rate aquisition is AutoNegotiation. Default value = r144kbps" ::= { sdslConfEntry 3 } sdslConfMode OBJECT-TYPE SYNTAX INTEGER { coe (1), -- HTU-C cpe (2) -- HTU-R } MAX-ACCESS read-write STATUS current DESCRIPTION "SDSL mode - COE (HTU-C) or CPE (HTU-R) Default value = COE" ::= { sdslConfEntry 4 } -- -- file :v:\doc\rdv\mib\ver485\radshdsl.txt -- --Version: 1.0 --Date: 9 Sep 02 --By: Yig'al Hachmon --File: radshdsl.txt -- --Last Update: Yig'al Hachmon 9-Sep-2002 --SHDSL configuration --wanGen OBJECT IDENTIFIER ::= {radWan 1} --diverseIfWanGen OBJECT IDENTIFIER ::= {wanGen 6} (see mpmx.txt) shdslIf OBJECT IDENTIFIER ::= {diverseIfWanGen 12} -- Segment Endpoint Current Status/Performance Group shdslEndpointCurrTable OBJECT-TYPE SYNTAX SEQUENCE OF ShdslEndpointCurrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is an extension of hdsl2ShdslEndpointCurrTable of rfc3276 It contains current status and performance information for segment endpoints in HDSL2/SHDSL Lines. As with other tables in this MIB indexed by ifIndex, entries in this table MUST be maintained in a persistent manner." ::= { shdslIf 1 } shdslEndpointCurrEntry OBJECT-TYPE SYNTAX ShdslEndpointCurrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the shdslEndpointCurrTable. Each entry contains status and performance information relating to a single segment endpoint. It is indexed by the ifIndex of the HDSL2/SHDSL line, the UnitId of the associated unit, the side of the unit, and the wire-pair of the associated modem." AUGMENTS {hdsl2ShdslEndpointCurrEntry} ::= { shdslEndpointCurrTable 1 } ShdslEndpointCurrEntry ::= SEQUENCE { hdsl2ShdslEndpointCurrRcvGain Integer32, hdsl2ShdslEndpointCurrTransPower Integer32, hdsl2ShdslEndpointCurrPowerBO Integer32, hdsl2ShdslEndpointCurrLineStatus INTEGER, hdsl2ShdslEndpointCurrOpState BITS, hdsl2ShdslEndpointAccumulatedTimeElapsed TimeTicks } hdsl2ShdslEndpointCurrRcvGain OBJECT-TYPE SYNTAX Integer32 UNITS "dB" MAX-ACCESS read-only STATUS current DESCRIPTION "The current receive gain in dB." ::= { shdslEndpointCurrEntry 1 } hdsl2ShdslEndpointCurrTransPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current transmit power in tenth of dBm." ::= { shdslEndpointCurrEntry 2 } hdsl2ShdslEndpointCurrPowerBO OBJECT-TYPE -- added by RAD SYNTAX Integer32 UNITS "dB" MAX-ACCESS read-only STATUS current DESCRIPTION "The current transceiver actual power packoff from 0dB to 6dB." ::= { shdslEndpointCurrEntry 3 } hdsl2ShdslEndpointCurrLineStatus OBJECT-TYPE -- added by RAD SYNTAX INTEGER { noSync (2), sync (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current line synchronization status." ::= { shdslEndpointCurrEntry 4 } hdsl2ShdslEndpointCurrOpState OBJECT-TYPE -- added by RAD SYNTAX BITS { idleMode(0), dataMode(1), bootUpload(2), bootUploadDone(3), startupHandshakeInProgress(4), startupTrainingInProgress(5), framerSyncInProgress(6), localAnalogLoopbackInProgress(7), remoteCoreLoopbackInProgress(8), localDigitalLoopbackInProgress(9), spectrumTestInProgress(10) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current operational state." ::= { shdslEndpointCurrEntry 5 } hdsl2ShdslEndpointAccumulatedTimeElapsed OBJECT-TYPE -- added by RAD SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "The time (in hundredths of a second) since the accumulated counters were last re-initialized: Accumulated counters are hdsl2ShdslEndpointES, hdsl2ShdslEndpointSES, hdsl2ShdslEndpointCRCanomalies hdsl2ShdslEndpointLOSWS, and hdsl2ShdslEndpointUAS." ::= { shdslEndpointCurrEntry 6 } shdslEndpointMaintTable OBJECT-TYPE SYNTAX SEQUENCE OF ShdslEndpointMaintEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table supports maintenance operations (eg. loopbacks) to be performed on HDSL2/SHDSL segment endpoints. This table contains live data from equipment. As such, it is NOT persistent." ::= { shdslIf 2 } shdslEndpointMaintEntry OBJECT-TYPE SYNTAX ShdslEndpointMaintEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the hdsl2ShdslEndpointMaintTable. Each entry corresponds to a single segment endpoint, and is indexed by the ifIndex of the HDSL2/SHDSL line, the UnitId of the associated unit and the side of the unit." INDEX { ifIndex, hdsl2ShdslInvIndex, hdsl2ShdslEndpointSide } ::= { shdslEndpointMaintTable 1 } ShdslEndpointMaintEntry ::= SEQUENCE { shdslMaintPowerBackOff INTEGER } shdslMaintPowerBackOff OBJECT-TYPE SYNTAX INTEGER { default(1), enhanced(2), disabled (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object configures the receiver at the associated segment endpoint to operate in default or enhanced power backoff mode. powerbackoff may also be disabled" ::= { shdslEndpointMaintEntry 1 } -- Span Configuration Profile Group shdslSpanConfProfileTable OBJECT-TYPE SYNTAX SEQUENCE OF ShdslSpanConfProfileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table supports definitions of span configuration profiles for SHDSL lines. HDSL2 does not support these configuration options. This table MUST be maintained in a persistent manner." ::= { shdslIf 3 } shdslSpanConfProfileEntry OBJECT-TYPE SYNTAX ShdslSpanConfProfileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry corresponds to a single span configuration profile. Each profile contains a set of span configuration parameters. The configuration parameters in a profile are applied to those lines referencing that profile (see the hdsl2ShdslSpanConfProfile object). Profiles may be created/deleted using the row creation/deletion mechanism via hdsl2ShdslSpanConfProfileRowStatus. If an active entry is referenced in hdsl2ShdslSpanConfProfile, the entry MUST remain active until all references are removed." AUGMENTS {hdsl2ShdslSpanConfProfileEntry} ::= { shdslSpanConfProfileTable 1 } ShdslSpanConfProfileEntry ::= SEQUENCE { hdsl2ShdslSpanConfEocCompatible INTEGER } hdsl2ShdslSpanConfEocCompatible OBJECT-TYPE -- Added by RAD SYNTAX INTEGER { proprietary (2), standard (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicate if device supports only standard EOC messages or also proprietary messages." ::= { shdslSpanConfProfileEntry 1 } hdsl2ShdslIfConf OBJECT IDENTIFIER ::= { shdslIf 4 } --Interface configuration with Configuration index hdsl2ShdslIfConfTable OBJECT-TYPE SYNTAX SEQUENCE OF Hdsl2ShdslIfConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table enables configuration of HDSL2/SHDSL interfaces per configuration index. Write operation for products supporting Active+Temp configurations, is possible only on the Temp configuration(255)." ::= { hdsl2ShdslIfConf 1 } hdsl2ShdslIfConfEntry OBJECT-TYPE SYNTAX Hdsl2ShdslIfConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the hdsl2ShdslIfConfTable. " INDEX { hdsl2ShdslIfConfIdx, ifIndex, hdsl2ShdslSideIdx} ::= { hdsl2ShdslIfConfTable 1 } Hdsl2ShdslIfConfEntry ::= SEQUENCE { hdsl2ShdslIfConfIdx Integer32, hdsl2ShdslSideIdx INTEGER, hdsl2ShdslMaxBw INTEGER, hdsl2ShdslPwrBackoff INTEGER, hdsl2ShdslTxMode INTEGER, hdsl2ShdslAttenuationThreshold Integer32, hdsl2ShdslSnrMarginThreshold Integer32, hdsl2ShdslTs0OverDsl INTEGER } hdsl2ShdslIfConfIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config. Write operation for products supporting Active+Temp configurations, is allowed to Temporary configuration only. " ::= {hdsl2ShdslIfConfEntry 1} hdsl2ShdslSideIdx OBJECT-TYPE SYNTAX INTEGER { nearEnd(2), farEnd (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Side of the managed object: Near-End or Far-End." ::= {hdsl2ShdslIfConfEntry 2} hdsl2ShdslMaxBw OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), r192 (2), r256 (3), r320 (4), r384 (5), r448 (6), r512 (7), r576 (8), r640 (9), r704 (10), r768 (11), r832 (12), r896 (13), r960 (14), r1024 (15), r1088 (16), r1152 (17), r1216 (18), r1280 (19), r1344 (20), r1408 (21), r1472 (22), r1536 (23), r1600 (24), r1664 (25), r1728 (26), r1792 (27), r1856 (28), r1920 (29), r1984 (30), r2048 (31) } MAX-ACCESS read-write STATUS current DESCRIPTION "Maximum BW (Bandwidth) of the Shdsl Line, in Kbps units. Respective Max No. of TSs = Max. Rate/64 This object can be Set only for a Central (xtuC) unit." ::= {hdsl2ShdslIfConfEntry 3} hdsl2ShdslPwrBackoff OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), enhanced(2), -- enabled disabled (3) -- added by RAD } MAX-ACCESS read-write STATUS current DESCRIPTION "This object configures the receiver at the associated segment endpoint to enable/disable power backoff mode. This object is similar to hdsl2ShdslMaintPowerBackOff, but per configuration. Therefore, the order of the enum values is the same. " ::= {hdsl2ShdslIfConfEntry 4} hdsl2ShdslTxMode OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), annexA (2), annexB (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object configures the Transmission Mode for the SHDSL Line. This object can be Set only for a Central (xtuC) unit." ::= { hdsl2ShdslIfConfEntry 5} hdsl2ShdslAttenuationThreshold OBJECT-TYPE SYNTAX Integer32 UNITS "dB" MAX-ACCESS read-write STATUS current DESCRIPTION "This object configures the Attentuation alarm threshold. 0=Off Valid values: 0..127 ." ::= { hdsl2ShdslIfConfEntry 6} hdsl2ShdslSnrMarginThreshold OBJECT-TYPE SYNTAX Integer32 UNITS "dB" MAX-ACCESS read-write STATUS current DESCRIPTION "This object configures the SNR margin alarm threshold. 0=Off Valid values: 0..15 ." ::= { hdsl2ShdslIfConfEntry 7} hdsl2ShdslTs0OverDsl OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), looped (2), transparent (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object configures the way TS0 will be treated over the SHDSL Line. looped - looped inside transparent - sent transparently over the DSL Line. This object can be Set only for a Central (xtuC) unit." ::= { hdsl2ShdslIfConfEntry 8} END