-- *************************************************************** -- ************************************************************* -- *********************************************************** -- ********************************************************* -- ** ** -- ** The ICN WN BA E12 SNMP-Team proudly presents: ** -- ** ** -- ** The XLD MIB ** -- ** for Performance Management ** -- ** on physical layer ** -- ** on drop area interfaces with ** -- ** ADSL ** -- ** and on feeder area interfaces for ** -- ** STM-1, STS3c, DS3, E3 ** -- ** LU-IMA ** -- ** ** -- ** ** -- ** for Performance Management ** -- ** on ATM layer ** -- ** at VPC or VPC segments or ** -- ** at VCC or VCC segments or ** -- ** ** -- ** ** -- ** ** -- ********************************************************* -- *********************************************************** -- ************************************************************* -- *************************************************************** XLDV20PM-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 Counter,TimeTicks,Gauge FROM RFC1155-SMI onu FROM AN-MIB -- -------------------------------------------------------------- -- I m p o r t s from X L D V 2 0 - M I B -- -------------------------------------------------------------- Xldv20ControlStatus, Xldv20AdminState, Xldv20FlowDirection, Unsigned16, Unsigned32, xldv20IfIndex, xldv20TvTimeAndDate, xldv20Traps FROM XLDV20-MIB; -- LAST-UPDATED "99-10-11, Version 2.0" -- ORGANIZATION "Siemens AG, ICN WN BA E" -- CONTACT-INFO -- " Angelika Svoboda -- ICN WN BA E 12 -- Tel.: +49 89 722 48063 -- -- Thomas Vetter -- ICN WN BA E 12 -- Tel.: +49 89 722 44323 -- -- ************************************************************** -- Versions and Revisions -- ************************************************************** -- -- -------------------------------------------------------------- -- 00-09-04 ADD: HPOV comment tags for HPVO - tools ....../tv -- -------------------------------------------------------------- -- 00-02-08 MR2441: extension description of V2.0 asvo -- xxxElapsedTime attributes -- -------------------------------------------------------------- -- 00-02-08 MR2410: change type of V2.0 asvo -- xldv20pmTvIntervalType -- -------------------------------------------------------------- -- 00-18-04 change types of threshold limits to V2.0 asvo -- Unsigned32 -- -------------------------------------------------------------- -- 00-22-03 change OID-sequnce from onu 6 to onu 5 V2.0 tv -- -------------------------------------------------------------- -- 00-29-02 First Issue of XLDV20PM-MIB V2.0 asvo -- -------------------------------------------------------------- -- -------------------------------------------------------------- -- ************************************************************** -- PLEASE CHANGE THE DATE OF LAST-UPDATE ABOVE !!! -- ************************************************************** -- ************************************************************** -- Information Block for Version Control -- of MIB nodes and attributes (template) -- ************************************************************** -- -- info-TRAPTYPE: alarm/event ==>> for traps only -- info-VALUE: minValue..maxValue; attrValue[(V1.0->)] -- info-TRAPID: trap-ID -- info-ROU: GET SET [db,gf,up,tm,hm,ut,so,sn,cp] -- info-FAILEDSRC: hwm, tlm, callp ==>> for alarm traps only -- info-FAILEDOBJ: [hwm] LU155,LUDSX3,LUPON,CMU,SUAD,SUVD,LTAD, -- info-FAILEDOBJ: [hwm] LIETH,LI25,NTAD,NTVD, -- info-FAILEDOBJ: [tlm] S1n(= STM-1 NePPTP),S1f,S3n,E3n,D3n,S3f, -- info-FAILEDOBJ: [tlm] D3f,E3f,Pon,Adc(= Adc-PPTP),Adr,Vdc,Vdr, -- info-FAILEDOBJ: [tlm] Ibm(= Ibm-PPTP),Eth,Tca -- info-FAILEDOBJ: [callp] VpcTP, VccTP -- info-IMPL: [V2.0,V2.x]:[rw,ro,*] -- info-IMPL: e.g.: V2.0-> (= all vers. begin. with V1.1U) -- info-IMPL: e.g.: V2.0:*->V2.1 V2.0:rw->2.1 V2.1:* -- info-VERCTRL: [GET,SET [db,asw,agent,blocked] or "-" -- (blocked == blocked by SNMP agent) -- ("-" == no special handling) -- ************************************************************** xldv20Pm OBJECT IDENTIFIER ::= { onu 5 } -- info-IMPL: V2.0-> -- info-VERCTRL: - -- ============================================================== -- TEXTUAL-CONVENTIONs for X L D V 2 0 P M - M I B -- ============================================================== -- -------------------------------------------------------------- -- T y p e s -- -------------------------------------------------------------- -- An Interval type identifier to select between the 15 minute -- counters and the day counter. -- Xldv20pmIntervalType ::= INTEGER { min15(1), day(2) } -- The PM Control request commands from the TMN-OS -- Xldv20pmControlReq ::= INTEGER { noRequest (1), resetIndividCurrent (2), setNrHistEntriesSize (3), paramFaulty (4), nrHistEntriesSizeNotAcceptable (5), dataDaseMemoryNotAvailable (6), create (7), -- PMo on Atm delete (8), -- PMo on Atm addEndpoint (9), -- PMo on Atm removeEndpoint (10), -- PMo on Atm indexLimitExceeded (11), -- PMo on Atm atmPmObjectActive (12), -- PMo on Atm atmPmObjectNotExists (13), -- PMo on Atm endpointExistsAlready (14), -- PMo on Atm requestBusy (15),-- user command handling setDataFailed (16),-- user command handling aswTimeout (17),-- user command handling commandFailed (18),-- user command handling commandSucceeded (19) -- user command handling } -- A type identifier to select the overall PM event counter -- These counters define a threshold limit profile. -- Xldv20pmCounterName ::= INTEGER { noPmCounter(0), neBackgroundBlockErrors(1), -- s1n, adc, e3n neCodeViolations(2), -- s3n neCodeViolationsCP(3), -- d3n neCodeViolationsP(4), -- d3n neCodeViolationsPLCP(5), -- d3n neErroredSeconds(6), -- s1n, s3n, adc, e3n neErroredSecondsCP(7), -- d3n neErroredSecondsPLCP(8), -- d3n neSas(9), -- d3n neSeverelyErroredFrameSeconds(10), -- s3n neSeverelyErroredSeconds(11), -- s1n, s3n, adc, e3n neSeverelyErroredSecondsCP(12), -- d3n neSeverelyErroredSecondsPLCP(13), -- d3n neUnavailableSeconds(14), -- s1n, s3n, adc, e3n neUnavailableSecondsPLCP(15), -- s3n neAisSeconds(16), -- s1n neOfsSeconds(17), -- s1n neLosSeconds(18), -- s1n feBackgroundBlockErrors(19), -- s1f, adr, e3f feCodeViolations(20), -- s3f feCodeViolationsCP(21), -- d3f feCodeViolationsPLCP(22), -- d3f feErroredSeconds(23), -- s1f, s3f, adr, e3f feErroredSecondsCP(24), -- d3f feErroredSecondsPLCP(25), -- d3f feSas(26), -- d3f feSeverelyErroredSeconds(27), -- s1f, s3f, adr, e3f feSeverelyErroredSecondsCP(28), -- d3f feSeverelyErroredSecondsPLCP(29), -- d3f feUnavailableSeconds(30), -- s1f, s3f, adr, e3f feUnavailableSecondsPLCP(31), -- s3f discardedCells(32), -- tca imaGroupUnavailSecs(33), -- IMA Group imaGroupNeNumFailures(34), -- IMA Group imaLinkImaViolations(35), -- IMA Link imaLinkOifAnomalies(36), -- IMA Link imaLinkNeSevErroredSecs(37), -- IMA Link imaLinkFeSevErroredSecs(38), -- IMA Link imaLinkNeUnavailSecs(39), -- IMA Link imaLinkFeUnavailSecs(40), -- IMA Link imaLinkNeTxUnusableSecs(41), -- IMA link imaLinkNeRxUnusableSecs(42), -- IMA link imaLinkFeTxUnusableSecs(43), -- IMA link imaLinkFeRxUnusableSecs(44), -- IMA link imaLinkNeTxNumFailures(45), -- IMA link imaLinkNeRxNumFailures(46), -- IMA link maxPmCounter(47) } -- A type identifier to select valid combination of TLM interfaces and OAM -- levels. To be used witin trap xldv20pmTrThresholdCrossingAlert. -- Xldv20pmType ::= INTEGER { pmTypeUnknown(0), s1F1PMo(1), -- for Performance Monitoring s1F2PMo(2), s1F3PMo(3), s3F1PMo(4), s3F2PMo(5), s3F3PMo(6), d3F2PMo(7), d3F3PMo(8), e3F3PMo(9), adcF3PMo(10), s1PrM(11), -- for Protocol Monitoring s3PrM(12), e3PrM(13), d3PrM(14), adcPrM(15), e1ImaPrM(16), -- for PrM on E1/Ds1 d1ImaPrM(17), e1ImaPMo(18), -- for PMo on E1/Ds1 d1ImaPMo(19), atmImaPMo(20), maxPmType(21) } -- -------------------------------------------------------------- -- T y p e s for PM on ATM layer -- -------------------------------------------------------------- -- An flow type identifier to select between the segement or -- endToEnd flow on F4 (VPC) or F5 (VCC) level -- Xldv20pmFlowType ::= INTEGER { undefined(0), f4Segment(1), f4EndToEnd(2), f5Segment(3), f5EndToEnd(4) } -- A type identifier to estimate the validity of a PM event -- counter -- Xldv20pmSuspectType ::= INTEGER { undefined(0), reliable(1), suspect(2) } -- A type which selects the type and termination point -- of cross connection index -- Xldv20pmConnectionIndexType ::= INTEGER { undefined(0), vplUni(1), vplNni(2), vclUni(3), vclNni(4) } -- A type which selects the role of endpoint -- Xldv20pmRoleType ::= INTEGER { undefined(0), analyseWithBackwardReporting(1), analyseWithoutBackwardReporting(2), generateWithCollect(3), generateWithoutCollect(4)} -- A type which selects the type of endpoint -- Xldv20pmEndpointType ::= INTEGER { source(1), sink(2) } -- A type which selects the block size -- A number of user cells after which a Pmo cell is inserted. -- Xldv20pmBlockSizeType ::= INTEGER { undefined(0), blockSize128(128), blockSize256(256), blockSize512(512), blockSize1024(1024) } Xldv20pmAtmCounterType ::= INTEGER { transmittedUserCells(1), lostUserCells(2), misinsertedUserCells(3) } -- ============================================================== -- M a i n g r o u p s of the X L D V 1 1 P M - M I B -- ============================================================== xldv20pmPerformanceManagementControl OBJECT IDENTIFIER ::= { xldv20Pm 1 } -- info-IMPL: V2.0-> -- info-VERCTRL: - xldv20pmPerformanceMonitoring OBJECT IDENTIFIER ::= { xldv20Pm 2 } -- info-IMPL: V2.0-> -- info-VERCTRL: - xldv20pmProtocolMonitoring OBJECT IDENTIFIER ::= { xldv20Pm 3 } -- info-IMPL: V2.0-> -- info-VERCTRL: - xldv20pmThresholding OBJECT IDENTIFIER ::= { xldv20Pm 4 } -- info-IMPL: V2.0-> -- info-VERCTRL: - xldv20pmTraps OBJECT IDENTIFIER ::= { xldv20Pm 5 } -- info-IMPL: V2.0-> -- info-VERCTRL: - -- ============================================================== -- P e r f o r m a n c e M a n a g e m e n t (PM) -- C o n t r o l g r o u p -- ============================================================== xldv20pmControl OBJECT IDENTIFIER -- info-IMPL: V2.0-> -- info-VERCTRL: - ::= { xldv20pmPerformanceManagementControl 1 } -- This managed entity manages the user commands for -- of Performance Mangement. -- -- An instance of this managed entity shall be automatically -- created by the ATM NE immediately following ATM NE -- initialization. xldv20pmCoIfIndex OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db SET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Unsigned16 ACCESS read-write STATUS mandatory DESCRIPTION " This attribute provides the interface index of the PM object for which PM parameters are configured . " --DEFAULT test-function-async fsnPmCoTest --DEFAULT next-function-async fsnPmCoNext --DEFAULT set-function-async fsnPmCoSet --DEFAULT get-function-async fsnPmCoGet ::= { xldv20pmControl 1 } xldv20pmCoNrHistEntriesSize OBJECT-TYPE -- info-VALUE: 1..96 -- info-ROU: GET db SET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (1..96) ACCESS read-write STATUS mandatory DESCRIPTION " This attribute is used to set the number of 15 minutes history entries which should be stored for history collection. Default value is 1. " --DEFAULT test-function-async fsnPmCoTest --DEFAULT next-function-async fsnPmCoNext --DEFAULT set-function-async fsnPmCoSet --DEFAULT get-function-async fsnPmCoGet ::= { xldv20pmControl 2 } xldv20pmCoIntervalType OBJECT-TYPE -- info-VALUE: min15(1), day(2) -- info-ROU: GET db SET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmIntervalType ACCESS read-write STATUS mandatory DESCRIPTION " This attribute identifies whether a 15 minutes interval or a day interval is selected in case of a resetIndividCurrent command. " --DEFAULT test-function-async fsnPmCoTest --DEFAULT next-function-async fsnPmCoNext --DEFAULT set-function-async fsnPmCoSet --DEFAULT get-function-async fsnPmCoGet ::= { xldv20pmControl 3 } xldv20pmCoControlReq OBJECT-TYPE -- info-VALUE: noRequest(1), resetIndividCurrent(2), -- info-VALUE: setNrHistEntriesSize(3), paramFaulty(4), -- info-VALUE: nrHistEntriesSizeNotAcceptable(5), -- info-VALUE: dataDaseMemoryNotAvailable(6) -- info-VALUE: requestBusy(15), setDataFailed(16), aswTimeout(17) -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmControlReq ACCESS read-write STATUS mandatory DESCRIPTION " This attribute identifies a control command given by the SNMP agent. A reset for any individual PM object is possible via command resetIndividCurrent. The command setNrHistEntriesSize is used to set the number of 15 minutes history entries for history collection at a particular interface. " --DEFAULT test-function-async fsnPmCoTest --DEFAULT next-function-async fsnPmCoNext --DEFAULT set-function-async fsnPmCoSet --DEFAULT get-function-async fsnPmCoGet ::= { xldv20pmControl 4 } xldv20pmCoControlStatus OBJECT-TYPE -- info-VALUE: requestIdle(1)..requestBusy(2), -- info-VALUE: requestPassed(3)..requestFailed(4) -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20ControlStatus ACCESS read-only STATUS mandatory DESCRIPTION " The status of a control request. " --DEFAULT next-function-async fsnPmCoNext --DEFAULT get-function-async fsnPmCoGet ::= { xldv20pmControl 5 } xldv20pmCoRemainingHistoryEntriesSize OBJECT-TYPE -- info-VALUE: 0..2000 -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..2000) ACCESS read-only STATUS mandatory DESCRIPTION " This attribute indicates the number of remaining history entries which are available for the 15 minutes history collection wthin the ONU. PM on physical and ATM layer use the same history memory which is limited in total to 2000 entries. The manager can read this attribute after the execution of the setNrHistEntriesSize command . " --DEFAULT next-function-async fsnPmCoNext --DEFAULT get-function-async fsnPmCoGet ::= { xldv20pmControl 6 } xldv20pmCoOAMLevel OBJECT-TYPE -- info-VALUE: 1..3 -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (1..3) ACCESS read-write STATUS mandatory DESCRIPTION " This attribute selects the OAM level f1 (1), f2 (2), f3 (3) . " --DEFAULT test-function-async fsnPmCoTest --DEFAULT next-function-async fsnPmCoNext --DEFAULT set-function-async fsnPmCoSet --DEFAULT get-function-async fsnPmCoGet ::= { xldv20pmControl 7 } xldv20pmCoControlReqResult OBJECT-TYPE -- info-VALUE: see Xldv20pmControlReq -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmControlReq ACCESS read-only STATUS mandatory DESCRIPTION " The result of the last user command. " --DEFAULT next-function-async fsnPmCoNext --DEFAULT get-function-async fsnPmCoGet ::= { xldv20pmControl 8 } xldv20pmCoControlTimeStamp OBJECT-TYPE -- info-VALUE: 0..2Giga -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION " The time stamp of the last command (end of command). " --DEFAULT next-function-async fsnPmCoNext --DEFAULT get-function-async fsnPmCoGet ::= { xldv20pmControl 9 } -- -------------------------------------------------------------- -- PMo on ATM Layer -- C o n t r o l O b j e c t -- -------------------------------------------------------------- xldv20pmAtmControl OBJECT IDENTIFIER -- info-IMPL: V2.0-> -- info-VERCTRL: - ::= { xldv20pmPerformanceManagementControl 2 } -- This managed entity manages the user commands for -- of Performance Mangement. -- -- An instance of this managed entity shall be automatically -- created by the ATM NE immediately following ATM NE -- initialization. xldv20pmAcoIndex OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db SET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Unsigned16 ACCESS read-write STATUS mandatory DESCRIPTION " This attribute provides the index of the AtmPm object for which PM parameters shall be configured . " --DEFAULT test-function-async fsnPmAcoTest --DEFAULT next-function-async fsnPmAcoNext --DEFAULT set-function-async fsnPmAcoSet --DEFAULT get-function-async fsnPmAcoGet ::= { xldv20pmAtmControl 1 } xldv20pmAcoNrHistEntriesSize OBJECT-TYPE -- info-VALUE: 1..96 (default 1) -- info-VALUE: day counter : 1, min15 counter : 1..96 -- info-ROU: GET db SET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (1..96) ACCESS read-write STATUS mandatory DESCRIPTION " This attribute is used to set the number of 15 minutes history entries which should be stored for history collection. The set HistEntrySize value is found in the xldv20pmAcHistEntrySize. " --DEFAULT test-function-async fsnPmAcoTest --DEFAULT next-function-async fsnPmAcoNext --DEFAULT set-function-async fsnPmAcoSet --DEFAULT get-function-async fsnPmAcoGet ::= { xldv20pmAtmControl 2 } xldv20pmAcoIntervalType OBJECT-TYPE -- info-VALUE: min15(1), day(2) -- info-ROU: GET db SET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmIntervalType ACCESS read-write STATUS mandatory DESCRIPTION " This attribute identifies whether a 15 minutes interval or a day interval is selected in case of a resetIndividCurrent command. " --DEFAULT test-function-async fsnPmAcoTest --DEFAULT next-function-async fsnPmAcoNext --DEFAULT set-function-async fsnPmAcoSet --DEFAULT get-function-async fsnPmAcoGet ::= { xldv20pmAtmControl 3 } xldv20pmAcoControlReq OBJECT-TYPE -- info-VALUE: noRequest(1), resetIndividCurrent(2), -- info-VALUE: setNrHistEntriesSize(3), paramFaulty(4), -- info-VALUE: nrHistEntriesSizeNotAcceptable(5), -- info-VALUE: dataDaseMemoryNotAvailable(6) -- info-VALUE: create(7), delete(8), addEndpoint(9), -- info-VALUE: removeEndpoint(10),indexLimitExceeded(11) -- info-VALUE: atmPmObjectActive(12), atmPmObjectNotExists(13), -- info-VALUE: atmPmObjectExistsAlready(14), endpointExistsAlready(15) -- info-VALUE: requestBusy(15), setDataFailed(16), aswTimeout(17) -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmControlReq ACCESS read-write STATUS mandatory DESCRIPTION " This attribute identifies a control command given by the SNMP agent. A reset for any individual PM object is possible via command resetIndividCurrent. The command setNrHistEntriesSize is used to set the number of 15 minutes history entries for history collection at a particular interface. The commands create/delete are used to create/delete AtmPm monitoring objectes (entry in table xldv20pmAtmObjectsTable). The commands addEndpoint/deleteEndpoint are used to add or delete AtmPm endpoints to/from an PMo monitoring object. " --DEFAULT test-function-async fsnPmAcoTest --DEFAULT next-function-async fsnPmAcoNext --DEFAULT set-function-async fsnPmAcoSet --DEFAULT get-function-async fsnPmAcoGet ::= { xldv20pmAtmControl 4 } xldv20pmAcoControlStatus OBJECT-TYPE -- info-VALUE: requestIdle(1)..requestBusy(2), -- info-VALUE: requestPassed(3)..requestFailed(4) -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20ControlStatus ACCESS read-only STATUS mandatory DESCRIPTION " The status of a control request. " --DEFAULT next-function-async fsnPmAcoNext --DEFAULT get-function-async fsnPmAcoGet ::= { xldv20pmAtmControl 5 } xldv20pmAcoRemainingHistoryEntriesSize OBJECT-TYPE -- info-VALUE: 0..2000 -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..2000) ACCESS read-only STATUS mandatory DESCRIPTION " This attribute indicates the number of remaining history entries which are available for the 15 minutes history collection within the ONU. PM on physical and ATM layer use the same history memory which is limited in total to 2000 entries. Commonly used by PM on physical and ATM layer The manager can read this attribute after the execution of the setNrHistEntriesSize command . " --DEFAULT next-function-async fsnPmAcoNext --DEFAULT get-function-async fsnPmAcoGet ::= { xldv20pmAtmControl 6 } xldv20pmAcoFlowType OBJECT-TYPE -- info-VALUE: f4Segment(1), f4EndToEnd(2) -- info-VALUE: f5Segment(3), f5EndToEnd(4) -- info-ROU: GET db SET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmFlowType ACCESS read-write STATUS mandatory DESCRIPTION " This attribute identifies the flow type : F4 (VP) or F5 (VC) segment or endToEnd flow. " --DEFAULT test-function-async fsnPmAcoTest --DEFAULT next-function-async fsnPmAcoNext --DEFAULT set-function-async fsnPmAcoSet --DEFAULT get-function-async fsnPmAcoGet ::= { xldv20pmAtmControl 7 } xldv20pmAcoFlowDirection OBJECT-TYPE -- info-VALUE: inwards(2), outwards(3) -- info-ROU: GET db SET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20FlowDirection ACCESS read-write STATUS mandatory DESCRIPTION " The flow direction of OAM cells. 'inwards' means flow direction from outside (external interface) to cross connection. 'outwards' means flow direction from inside to external interface. " --DEFAULT test-function-async fsnPmAcoTest --DEFAULT next-function-async fsnPmAcoNext --DEFAULT set-function-async fsnPmAcoSet --DEFAULT get-function-async fsnPmAcoGet ::= { xldv20pmAtmControl 8 } xldv20pmAcoConnectionIndex OBJECT-TYPE -- info-VALUE: 1..2048 -- info-ROU: GET db SET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (1..2048) ACCESS read-write STATUS mandatory DESCRIPTION " This attribute identifies the index of a Vpl or Vcl cross connection. " --DEFAULT test-function-async fsnPmAcoTest --DEFAULT next-function-async fsnPmAcoNext --DEFAULT set-function-async fsnPmAcoSet --DEFAULT get-function-async fsnPmAcoGet ::= { xldv20pmAtmControl 9 } xldv20pmAcoConnectionIndexType OBJECT-TYPE -- info-VALUE: vplUni(1),vplNni(2),vclUni(3),vclNni(4) -- info-ROU: GET db SET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmConnectionIndexType ACCESS read-write STATUS mandatory DESCRIPTION " This attribute identifies the type of connection index and the termination point. It is in case of vplUni/vplNni : index of Vpl CC (xldv20AccVpiNniIndex) vclUni/vplNni : index of Vcl CC (xldv20VcxIndex). " --DEFAULT test-function-async fsnPmAcoTest --DEFAULT next-function-async fsnPmAcoNext --DEFAULT set-function-async fsnPmAcoSet --DEFAULT get-function-async fsnPmAcoGet ::= { xldv20pmAtmControl 10 } xldv20pmAcoRole OBJECT-TYPE -- info-VALUE: analyseWithBackwardReporting(1), -- info-VALUE: analyseWithoutBackwardReporting(2), -- info-VALUE: generateWithCollect(3), generateWithoutCollect(4) -- info-ROU: GET db SET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmRoleType ACCESS read-write STATUS mandatory DESCRIPTION " The role of endpoint. 'analyseWithBackwardReporting' (sink) means extracting forward monitoring (FM) OAM cells, sending back backward reporting OAM cells and no data collection for current and history table. 'analyseWithoutBackwardReporting' (sink) means extracting FM cells without any other OAM handling and also collecting data. 'generateWithCollect' (source) means inserting FM cells, extracting backward reporting cells if they arrive and collect data for current and history table. 'generateWithoutCollect' (source) means inserting FM cells but without collecting data. The CMU, the Ethernet part of the Twin NT s capable of operating as inserting or extracting point. " --DEFAULT test-function-async fsnPmAcoTest --DEFAULT next-function-async fsnPmAcoNext --DEFAULT set-function-async fsnPmAcoSet --DEFAULT get-function-async fsnPmAcoGet ::= { xldv20pmAtmControl 12 } xldv20pmAcoEndpointType OBJECT-TYPE -- info-VALUE: source(1), sink(2) -- info-ROU: GET db SET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmEndpointType ACCESS read-write STATUS mandatory DESCRIPTION " Identifies the type of endpoint. " --DEFAULT test-function-async fsnPmAcoTest --DEFAULT next-function-async fsnPmAcoNext --DEFAULT set-function-async fsnPmAcoSet --DEFAULT get-function-async fsnPmAcoGet ::= { xldv20pmAtmControl 13 } xldv20pmAcoControlReqResult OBJECT-TYPE -- info-VALUE: see Xldv20pmControlReq -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmControlReq ACCESS read-only STATUS mandatory DESCRIPTION " The result of the last user command. " --DEFAULT next-function-async fsnPmAcoNext --DEFAULT get-function-async fsnPmAcoGet ::= { xldv20pmAtmControl 14 } xldv20pmAcoControlTimeStamp OBJECT-TYPE -- info-VALUE: 0..2Giga -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION " The time stamp of the last command (end of command). " --DEFAULT next-function-async fsnPmAcoNext --DEFAULT get-function-async fsnPmAcoGet ::= { xldv20pmAtmControl 15 } -- ============================================================== -- P e r f o r m a n c e M o n i t o r i n g (PMo) -- g r o u p -- ============================================================== -- ------------------------------------------------------------------ -- PMo o n p h y s i c a l l a y e r -- ------------------------------------------------------------------ -- -- Description of the PMo Events of the PM common group. -- To the common group belong those type of TLM interfaces -- which have the same performance monitoring counters. -- These are the interface types : adc, adr, vdc, vdr, e3n, e3f. -- -- Errored Seconds (ES) -- An Errored Second is a one second interval containing one or -- more crc-i or crc-ni anomalies, or one or more loss of signal -- or severely errored frame (SEF) defects applicable to adc/adr -- interfaces -- -- Severely Errored Seconds (SEF) -- A one second period in which at least 30% of the blocks are in -- error or as a one second period which contains a Severely -- Disturbed Period . SDP is usually estimated as the occurrence -- of a network defect, such as loss of signal, loss of frame, -- or other alarm indicators -- -- Background Block Error (BBE) -- A Background Block Error is an errored-block not occurring as -- part of an SES -- -- Unavailable Seconds (UAS) -- A period of unavailable time begins at the onset of 10 consecu- -- tive SES events. These ten seconds are considered to be part of -- unavailable time. A new period of available time begins at the -- onset of ten consecutive non-SES events. These 10 seconds are -- considered to be part of available time. -- Note: during Unavailable Seconds (UAS), performance parameters -- are not counted, exception is the UAS themselves, they -- are counted further. -- -------------------------------------------------------------- -- PMo Common Current Data Table -- -------------------------------------------------------------- xldv20pmCommonCurrentTable OBJECT-TYPE -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX SEQUENCE OF Xldv20pmCommonCurrentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " This table contains the entries for the current 15 minute interval or the current day of PMo objects of the common group. (adc, adr, e3n and e3f) . " --DEFAULT test-function-async fsnPmCcEntryTest --DEFAULT next-function-async fsnPmCcEntryNext --DEFAULT set-function-async fsnPmCcEntrySet --DEFAULT get-function-async fsnPmCcEntryGet ::= { xldv20pmPerformanceMonitoring 2 } xldv20pmCommonCurrentEntry OBJECT-TYPE -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmCommonCurrentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " An entry describing the Common Current Data Table . " INDEX { xldv20IfIndex, xldv20pmCcIntervalType, xldv20pmCcOAMLevel } ::= { xldv20pmCommonCurrentTable 1 } Xldv20pmCommonCurrentEntry ::= SEQUENCE { xldv20pmCcIntervalType Xldv20pmIntervalType, xldv20pmCcOAMLevel INTEGER, xldv20pmCcAdminState Xldv20AdminState, xldv20pmCcSuspectFlag Xldv20pmSuspectType, xldv20pmCcHistEntrySize INTEGER, xldv20pmCcNrHistEntriesAvailable INTEGER, xldv20pmCcElapsedTime INTEGER, xldv20pmCcThresholdLimitIndex INTEGER, xldv20pmCcNeErroredSeconds Counter, xldv20pmCcFeErroredSeconds Counter, xldv20pmCcNeSeverelyErroredSeconds Counter, xldv20pmCcFeSeverelyErroredSeconds Counter, xldv20pmCcNeBackgroundBlockErrors Counter, xldv20pmCcFeBackgroundBlockErrors Counter, xldv20pmCcNeUnavailableSeconds Counter, xldv20pmCcFeUnavailableSeconds Counter } xldv20pmCcIntervalType OBJECT-TYPE -- info-VALUE: min15(1), day(2) -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmIntervalType ACCESS read-only STATUS mandatory DESCRIPTION " This attribute is used to select between the 15 min or the day accumulation types. " ::= { xldv20pmCommonCurrentEntry 1 } xldv20pmCcOAMLevel OBJECT-TYPE -- info-VALUE: 1..3 -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (1..3) ACCESS read-only STATUS mandatory DESCRIPTION " This attribute is used to select between the 3 OAM levels f1 (1), f2 (2) and f3 (3) . " ::= { xldv20pmCommonCurrentEntry 2 } xldv20pmCcAdminState OBJECT-TYPE -- info-VALUE: unlocked(1), locked(2) -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20AdminState ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute is used to activate (unlock) and deactivate (lock) the functions (incl. collection) performed by this managed entity. Note: the 15min collection object must be activated, before day collection can operate. " ::= { xldv20pmCommonCurrentEntry 3 } xldv20pmCcSuspectFlag OBJECT-TYPE -- info-VALUE: reliable(1), suspect(2) -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmSuspectType ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute will be set to indicate that troubles arose during an interval and that the counter values are suspect and incomplete. " ::= { xldv20pmCommonCurrentEntry 4 } xldv20pmCcHistEntrySize OBJECT-TYPE -- info-VALUE: 1..96 -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (1..96) ACCESS read-only STATUS mandatory DESCRIPTION " The number of 15min history entries configured at the particular interface. This attribute is used for history data collection. The default value is 1 and means at least one history entry is desired . " ::= { xldv20pmCommonCurrentEntry 5 } xldv20pmCcNrHistEntriesAvailable OBJECT-TYPE -- info-VALUE: 0..96 -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..96) ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute indicates how many HistEntries are already available. The range of values is between 0 and xldv20pmCcHistEntrySize, thereby 0 means that this entry is not valid . " ::= { xldv20pmCommonCurrentEntry 6 } xldv20pmCcElapsedTime OBJECT-TYPE -- info-VALUE: 0..900 (sec) for min15, -- info-VALUE: 0..1440 (min) for day -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER(0..1440) ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents the difference between the current time and the start of the present summary interval. Units are seconds when 15 minute interval is selected or minutes for day interval. (Note: accurate to the sample time interval). " ::= { xldv20pmCommonCurrentEntry 7 } xldv20pmCcThresholdLimitIndex OBJECT-TYPE -- info-VALUE: 1..30 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (1..30) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute provides an index to the ThresholdLimitTable managed entity that contains the threshold limits for the performance parameters reported by this managed entity. When the value of this attribute is set to 1, default threshold limits shall be used . " ::= { xldv20pmCommonCurrentEntry 8 } xldv20pmCcNeErroredSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " A near end counter of Errored Seconds (ES) over a 15 min/day interval. Counter appearence depends on interface type and OAM level : - adc, e3n: valid for F3 level . " ::= { xldv20pmCommonCurrentEntry 9 } xldv20pmCcFeErroredSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " A far end counter of Errored Seconds (ES) over a 15 min /day interval. Counter appearence depends on interface type and OAM level : - adr, e3f: valid for F3 level . " ::= { xldv20pmCommonCurrentEntry 10 } xldv20pmCcNeSeverelyErroredSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " Represents a near end counter of Severely Errored Seconds (SES) over a 15 min /day interval. Counter appearence depends on interface type and OAM level : - adc, e3n: valid for F3 level . " ::= { xldv20pmCommonCurrentEntry 11 } xldv20pmCcFeSeverelyErroredSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a far end counter of Severely Errored Seconds (SES) over a 15 min /day interval. Counter appearence depends on interface type and OAM level : - adr, e3f: valid for F3 level . " ::= { xldv20pmCommonCurrentEntry 12 } xldv20pmCcNeBackgroundBlockErrors OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a near end counter for Background Block Errors (BBE) over a 15 min /day interval. Counter appearence depends on interface type and OAM level : - adc, e3n: valid for F3 level . " ::= { xldv20pmCommonCurrentEntry 13 } xldv20pmCcFeBackgroundBlockErrors OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a far end counter for Background Block Errors (BBE) over a 15 min /day interval. Counter appearence depends on interface type and OAM level : - adr, e3f: valid for F3 level . " ::= { xldv20pmCommonCurrentEntry 14 } xldv20pmCcNeUnavailableSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of Unavailable Seconds (UAS) within the current 15 minute interval or current day. Counter applicable for : adc, e3n and f3 level . " ::= { xldv20pmCommonCurrentEntry 15 } xldv20pmCcFeUnavailableSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a far end counter of Unavailable Seconds (UAS) within the current 15 minute interval or current day. Counter applicable for : adr, e3f and F3 level . " ::= { xldv20pmCommonCurrentEntry 16 } -- -------------------------------------------------------------- -- PMo C o m m o n H i s t o r y D a t a Table -- -------------------------------------------------------------- xldv20pmCommonHistoryTable OBJECT-TYPE -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX SEQUENCE OF Xldv20pmCommonHistoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " This table contains the entries for the PMo objects of the 15 min /one day-history data collection results at the respective adc, adr drop area interfaces . " --DEFAULT get-function-async fsnPmChEntryGet --DEFAULT next-function-async fsnPmChEntryNext ::= { xldv20pmPerformanceMonitoring 3 } xldv20pmCommonHistoryEntry OBJECT-TYPE -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmCommonHistoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " An entry describing the Common History Data Table . " INDEX { xldv20IfIndex, xldv20pmChIntervalType, xldv20pmChOAMLevel, xldv20pmChHistEntryNr } ::= { xldv20pmCommonHistoryTable 1 } Xldv20pmCommonHistoryEntry ::= SEQUENCE { xldv20pmChIntervalType Xldv20pmIntervalType, xldv20pmChOAMLevel INTEGER, xldv20pmChHistEntryNr INTEGER, xldv20pmChSuspectFlag Xldv20pmSuspectType, xldv20pmChPeriodEndTime INTEGER, xldv20pmChNeErroredSeconds Counter, xldv20pmChFeErroredSeconds Counter, xldv20pmChNeSeverelyErroredSeconds Counter, xldv20pmChFeSeverelyErroredSeconds Counter, xldv20pmChNeBackgroundBlockErrors Counter, xldv20pmChFeBackgroundBlockErrors Counter, xldv20pmChNeUnavailableSeconds Counter, xldv20pmChFeUnavailableSeconds Counter } xldv20pmChIntervalType OBJECT-TYPE -- info-VALUE: min 5(1), day(2) -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmIntervalType ACCESS read-only STATUS mandatory DESCRIPTION " This type attribute is used to select between the 15 min or the day accumulation types. " ::= { xldv20pmCommonHistoryEntry 1 } xldv20pmChOAMLevel OBJECT-TYPE -- info-VALUE: 1..3 -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (1..3) ACCESS read-only STATUS mandatory DESCRIPTION " This attribute is used to select between the 3 OAM levels f1 (1), f2 (2) and f3 (3) . " ::= { xldv20pmCommonHistoryEntry 2 } xldv20pmChHistEntryNr OBJECT-TYPE -- info-VALUE: 1..96 -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (1..96) ACCESS read-only STATUS mandatory DESCRIPTION " This attribute is an index used to address the PM history entry. Entry 1 is the most recent, entry 96 is 24 hours ago. The range of values is between 1 and xldv20pmCcHistEntrySize . " ::= { xldv20pmCommonHistoryEntry 3 } xldv20pmChSuspectFlag OBJECT-TYPE -- info-VALUE: reliable(1), suspect(2) -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmSuspectType ACCESS read-only STATUS mandatory DESCRIPTION " Will be set to indicate that troubles arose during an interval and that the counter values are suspect and incomplete. " ::= { xldv20pmCommonHistoryEntry 4 } xldv20pmChPeriodEndTime OBJECT-TYPE -- info-VALUE: 0..2147483647 -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION " Date/time at the end of the selected interval. " ::= { xldv20pmCommonHistoryEntry 5 } xldv20pmChNeErroredSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a near end counter of Errored Seconds (ES) over a 15 min /day interval. Counter applicable for : adc, e3n and F3 level . " ::= { xldv20pmCommonHistoryEntry 6 } xldv20pmChFeErroredSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a far end counter of Errored Seconds (ES) within the current 15 minute interval or current day. Counter applicable for : adr, e3f and F3 level . " ::= { xldv20pmCommonHistoryEntry 7 } xldv20pmChNeSeverelyErroredSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a near end counter of Severely Errored Seconds (SES) within the current 15 minute interval or current day. Counter applicable for : adc, e3n and F3 level . " ::= { xldv20pmCommonHistoryEntry 8 } xldv20pmChFeSeverelyErroredSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a far end counter of Severely Errored Seconds (SES) within the current 15 minute interval or current day. Counter applicable for : adr, e3f and F3 level . " ::= { xldv20pmCommonHistoryEntry 9 } xldv20pmChNeBackgroundBlockErrors OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a near end counter for Background Block Errors (BBE) over a 15 min /day interval. Counter applicable for : adc, e3n and F3 level . " ::= { xldv20pmCommonHistoryEntry 10 } xldv20pmChFeBackgroundBlockErrors OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a far end counter for Background Block Errors (BBE) over a 15 min /day interval. Counter applicable for : adr, e3n and F3 level . " ::= { xldv20pmCommonHistoryEntry 11 } xldv20pmChNeUnavailableSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a near end counter of Unavailable Seconds (UAS) for a 15 min /day interval. Counter applicable for : adc, e3n and F3 level . " ::= { xldv20pmCommonHistoryEntry 12 } xldv20pmChFeUnavailableSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a far end counter of Unavailable Seconds (UAS) for a 15 min /day interval. Counter applicable for : adr, e3f and F3 level . " ::= { xldv20pmCommonHistoryEntry 13 } -- -------------------------------------------------------------- -- Pmo S T S 3 C u r r e n t D a t a Table -- -------------------------------------------------------------- xldv20pmS3CurrentTable OBJECT-TYPE -- info-IMPL: V2.0-> SYNTAX SEQUENCE OF Xldv20pmS3CurrentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " This table contains the entries for the current 15 minute interval or the current day for STS3c near-end and far-end PPTPs. " --DEFAULT test-function-async fsnPmS3cEntryTest --DEFAULT next-function-async fsnPmS3cEntryNext --DEFAULT set-function-async fsnPmS3cEntrySet --DEFAULT get-function-async fsnPmS3cEntryGet ::= { xldv20pmPerformanceMonitoring 4 } xldv20pmS3CurrentEntry OBJECT-TYPE -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmS3CurrentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " An entry describing the STS3 near-end and far-end Current Data Table . " INDEX { xldv20IfIndex, xldv20pmS3cIntervalType, xldv20pmS3cOAMLevel } ::= { xldv20pmS3CurrentTable 1 } Xldv20pmS3CurrentEntry ::= SEQUENCE { xldv20pmS3cIntervalType Xldv20pmIntervalType, xldv20pmS3cOAMLevel INTEGER, xldv20pmS3cAdminState Xldv20AdminState, xldv20pmS3cSuspectFlag Xldv20pmSuspectType, xldv20pmS3cHistEntrySize INTEGER, xldv20pmS3cNrHistEntriesAvailable INTEGER, xldv20pmS3cElapsedTime INTEGER, xldv20pmS3cThresholdLimitIndex INTEGER, xldv20pmS3cNeErroredSeconds Counter, xldv20pmS3cFeErroredSeconds Counter, xldv20pmS3cNeSeverelyErroredSeconds Counter, xldv20pmS3cFeSeverelyErroredSeconds Counter, xldv20pmS3cNeCodeViolations Counter, xldv20pmS3cFeCodeViolations Counter, xldv20pmS3cNeUnavailableSeconds Counter, xldv20pmS3cFeUnavailableSeconds Counter, xldv20pmS3cNeSeverelyErroredFrameSeconds Counter } xldv20pmS3cIntervalType OBJECT-TYPE -- info-VALUE: min15(1), day(2) -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmIntervalType ACCESS read-only STATUS mandatory DESCRIPTION " This type attribute is used to select between the 15 min or the day accumulation types. " ::= { xldv20pmS3CurrentEntry 1 } xldv20pmS3cOAMLevel OBJECT-TYPE -- info-VALUE: 1..3 -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (1..3) ACCESS read-only STATUS mandatory DESCRIPTION " This attribute is used to select between the 3 OAM levels f1 (1), f2 (2) and f3 (3) . " ::= { xldv20pmS3CurrentEntry 2 } xldv20pmS3cAdminState OBJECT-TYPE -- info-VALUE: unlocked(1), locked(2) -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20AdminState ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute is used to activate (unlock) and deactivate (lock) the functions (incl. collection) performed by this managed entity. Note: the 15min collection object must be activated, before day collection can operate. " ::= { xldv20pmS3CurrentEntry 3 } xldv20pmS3cSuspectFlag OBJECT-TYPE -- info-VALUE: reliable(1), suspect(2) -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmSuspectType ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute will be set to indicate that troubles arose during an interval and that the counter values are suspect and incomplete. " ::= { xldv20pmS3CurrentEntry 4 } xldv20pmS3cHistEntrySize OBJECT-TYPE -- info-VALUE: 1..96 -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (1..96) ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute indicates the number of 15min history entries configured at the particular interface. The default value is 1 and means that at least one history entry is provided . " ::= { xldv20pmS3CurrentEntry 5 } xldv20pmS3cNrHistEntriesAvailable OBJECT-TYPE -- info-VALUE: 0..96 -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..96) ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute indicates how many history entries are already available. The range of values is between 0 and xldv20S3cHistEntrySize, thereby 0 means that this entry is not valid . " ::= { xldv20pmS3CurrentEntry 6 } xldv20pmS3cElapsedTime OBJECT-TYPE -- info-VALUE: 0..900 (sec) for min15 -- info-VALUE: 0..1440 (min) for day -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..1440) ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents the difference between the current time and the start of the present summary interval. Units are seconds when 15 minute interval is selected or minutes for day interval. (Note: accurate to the sample time interval). " ::= { xldv20pmS3CurrentEntry 7 } xldv20pmS3cThresholdLimitIndex OBJECT-TYPE -- info-VALUE: 1..30 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (1..30) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute provides an index to the ThresholdLimitTable managed entity that contains the threshold limits for the performance parameters reported by this managed entity. When the value of this attribute is set to 1, default threshold limits shall be used The range of values is [1,30]. " ::= { xldv20pmS3CurrentEntry 8 } xldv20pmS3cNeErroredSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET SET [db,pm] -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of Errored Seconds (ES) within the current 15min interval or current day. Counter applicable for : s3n and F1, F2, F3 levels . " ::= { xldv20pmS3CurrentEntry 9 } xldv20pmS3cFeErroredSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET SET [db,pm] -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of Errored Seconds (ES) within the current 15min interval or current day. Counter applicable for : s3f and F2 and F3 levels . " ::= { xldv20pmS3CurrentEntry 10 } xldv20pmS3cNeSeverelyErroredSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET SET [db,pm] -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of Severely Errored Seconds (SES) within the current 15min interval or current day. Counter applicable for : s3n and F2 and F3 levels . " ::= { xldv20pmS3CurrentEntry 11 } xldv20pmS3cFeSeverelyErroredSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET SET [db,pm] -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of Severely Errored Seconds (SES) within the current 15min interval or current day. Counter applicable for : s3f and for F2 and F3 levels . " ::= { xldv20pmS3CurrentEntry 12 } xldv20pmS3cNeCodeViolations OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of Code Violations Errors within the current 15min interval or current day. Counter applicable for : s3n and F1, F2, F3 levels . " ::= { xldv20pmS3CurrentEntry 13 } xldv20pmS3cFeCodeViolations OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of Code Violations Errors within the current 15min interval or current day. Counter applicable for : s3f and F2 and F3 levels . " ::= { xldv20pmS3CurrentEntry 14 } xldv20pmS3cNeUnavailableSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of Unavailable Seconds (UAS) within the current 15min interval or current day. Counter applicable for : s3n and F2 and F3 levels . " ::= { xldv20pmS3CurrentEntry 15 } xldv20pmS3cFeUnavailableSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of Unavailable Seconds (UAS) within the current 15min interval or current day. Counter applicable for : s3f and level F2 and F3 . " ::= { xldv20pmS3CurrentEntry 16 } xldv20pmS3cNeSeverelyErroredFrameSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of Severely Errored Frame Seconds within the current 15min interval or current day. Counter applicable for : s3n and F1 level only. " ::= { xldv20pmS3CurrentEntry 17 } -- -------------------------------------------------------------- -- Pmo S T S 3 H i s t o r y D a t a Table -- -------------------------------------------------------------- xldv20pmS3HistoryTable OBJECT-TYPE -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX SEQUENCE OF Xldv20pmS3HistoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " This table contains the entries for the PMo history objects at the near-end and far-end STS3c interfaces. It contains results that are overtaken from the s3CurrentTable PM-object at the end of a 15 min /day interval . " --DEFAULT next-function-async fsnPmS3hEntryNext --DEFAULT get-function-async fsnPmS3hEntryGet ::= { xldv20pmPerformanceMonitoring 5 } xldv20pmS3HistoryEntry OBJECT-TYPE -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmS3HistoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " An entry describing the STS3 near-end and far-end History Data Table . " INDEX { xldv20IfIndex, xldv20pmS3hIntervalType, xldv20pmS3hOAMLevel, xldv20pmS3hHistEntryNr } ::= { xldv20pmS3HistoryTable 1 } Xldv20pmS3HistoryEntry ::= SEQUENCE { xldv20pmS3hIntervalType Xldv20pmIntervalType, xldv20pmS3hOAMLevel INTEGER, xldv20pmS3hHistEntryNr INTEGER, xldv20pmS3hSuspectFlag Xldv20pmSuspectType, xldv20pmS3hPeriodEndTime INTEGER, xldv20pmS3hNeErroredSeconds Counter, xldv20pmS3hFeErroredSeconds Counter, xldv20pmS3hNeSeverelyErroredSeconds Counter, xldv20pmS3hFeSeverelyErroredSeconds Counter, xldv20pmS3hNeCodeViolations Counter, xldv20pmS3hFeCodeViolations Counter, xldv20pmS3hNeUnavailableSeconds Counter, xldv20pmS3hFeUnavailableSeconds Counter, xldv20pmS3hNeSeverelyErroredFrameSeconds Counter } xldv20pmS3hIntervalType OBJECT-TYPE -- info-VALUE: min15(1) , day(2) -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmIntervalType ACCESS read-only STATUS mandatory DESCRIPTION " This type attribute is used to select between the 15 min or the day accumulation types. " ::= { xldv20pmS3HistoryEntry 1 } xldv20pmS3hOAMLevel OBJECT-TYPE -- info-VALUE: 1(f1), 2(f2), 3(f3) -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (1..3) ACCESS read-only STATUS mandatory DESCRIPTION " This attribute is used to select between the 3 OAM levels f1 (1), f2 (2) and f3 (3) . " ::= { xldv20pmS3HistoryEntry 2 } xldv20pmS3hHistEntryNr OBJECT-TYPE -- info-VALUE: 1..96 -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (1..96) ACCESS read-only STATUS mandatory DESCRIPTION " This attribute is used as index to address the history entry. Entry 1 is the most recent, entry 96 is 24 hours ago. The range of values is between 1 and xldv20S3cHistEntrySize . " ::= { xldv20pmS3HistoryEntry 3 } xldv20pmS3hSuspectFlag OBJECT-TYPE -- info-VALUE: reliable(1), suspect(2) -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmSuspectType ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute will be set to indicate that troubles arose during an interval and that the counter values are suspect and incomplete. " ::= { xldv20pmS3HistoryEntry 4 } xldv20pmS3hPeriodEndTime OBJECT-TYPE -- info-VALUE: 0..2147483647 -- info-ROU: GET SET [db,pm] -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER(0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute is a record of date/time at the end of an interval . " ::= { xldv20pmS3HistoryEntry 5 } xldv20pmS3hNeErroredSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a set of history counter for Errored Seconds (ES) for the passed up to 96 periods of 15 minutes and the passed day interval. Counter applicable for : s3n and F1, F2, F3 levels . " ::= { xldv20pmS3HistoryEntry 6 } xldv20pmS3hFeErroredSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a set of history counter for Errored Seconds (ES) for the passed up to 96 periods of 15 minutes and the passed day interval. Counter applicable for : s3f and F2 and F3 levels . " ::= { xldv20pmS3HistoryEntry 7 } xldv20pmS3hNeSeverelyErroredSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a set of history counter for Severely Errored Seconds (SES) for the passed up to 96 periods of 15 minutes and the passed day interval. Counter applicable for : s3n and F2 and F3 levels . " ::= { xldv20pmS3HistoryEntry 8 } xldv20pmS3hFeSeverelyErroredSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a set of history counter for Severely Errored Seconds (SES) for the passed up to 96 periods of 15 minutes and the passed day interval. Counter applicable for : s3f and F2 and F3 levels . " ::= { xldv20pmS3HistoryEntry 9 } xldv20pmS3hNeCodeViolations OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a set of history counter for Code Violations Errors for the passed up to 96 periods of 15 minutes and the passed day interval. Counter applicable for : s3n and F1, F2, F3 levels . " ::= { xldv20pmS3HistoryEntry 10 } xldv20pmS3hFeCodeViolations OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a set of history counter for Code Violations Errors for the passed up to 96 periods of 15 minutes and the passed day interval. Counter applicable for : s3f and F2 and F3 levels . " ::= { xldv20pmS3HistoryEntry 11 } xldv20pmS3hNeUnavailableSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a set of history counter for Unavailable Seconds (UAS) for the passed up to 96 periods of 15 minutes and the passed day interval. Counter applicable for : s3n and F2 and F3 levels . " ::= { xldv20pmS3HistoryEntry 12 } xldv20pmS3hFeUnavailableSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a set of history counter for Unavailable Seconds (UAS) for the passed up to 96 periods of 15 minutes and the passed day interval. Counter applicable for : s3f and F2 and F3 levels . " ::= { xldv20pmS3HistoryEntry 13 } xldv20pmS3hNeSeverelyErroredFrameSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a set of history counter for Severely Errored Frame Seconds for the passed up to 96 periods of 15 minutes and the passed day interval. Counter applicable for : s3n and F1 level only . " ::= { xldv20pmS3HistoryEntry 14 } -- -------------------------------------------------------------- -- PMo D S 3 C u r r e n t D a t a Table -- -------------------------------------------------------------- xldv20pmD3CurrentTable OBJECT-TYPE -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX SEQUENCE OF Xldv20pmD3CurrentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " This table contains the entries for the current 15 minute interval or the current day for DS3 near-end and far-end PPTPs. Note: Day PM collection uses the 15min interval results . " --DEFAULT test-function-async fsnPmD3cEntryTest --DEFAULT next-function-async fsnPmD3cEntryNext --DEFAULT set-function-async fsnPmD3cEntrySet --DEFAULT get-function-async fsnPmD3cEntryGet ::= { xldv20pmPerformanceMonitoring 6 } xldv20pmD3CurrentEntry OBJECT-TYPE -- info-VALUE: - -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmD3CurrentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " An entry describing the DS3 near-end and far-end Current Data Table . " INDEX { xldv20IfIndex, xldv20pmD3cIntervalType, xldv20pmD3cOAMLevel } ::= { xldv20pmD3CurrentTable 1 } Xldv20pmD3CurrentEntry ::= SEQUENCE {xldv20pmD3cIntervalType Xldv20pmIntervalType, xldv20pmD3cOAMLevel INTEGER, xldv20pmD3cAdminState Xldv20AdminState, xldv20pmD3cSuspectFlag Xldv20pmSuspectType, xldv20pmD3cHistEntrySize INTEGER, xldv20pmD3cNrHistEntriesAvailable INTEGER, xldv20pmD3cElapsedTime INTEGER, xldv20pmD3cThresholdLimitIndex INTEGER, xldv20pmD3cNeErroredSecondsCP Counter, xldv20pmD3cFeErroredSecondsCP Counter, xldv20pmD3cNeErroredSecondsPLCP Counter, xldv20pmD3cFeErroredSecondsPLCP Counter, xldv20pmD3cNeSeverelyErroredSecondsCP Counter, xldv20pmD3cFeSeverelyErroredSecondsCP Counter, xldv20pmD3cNeSeverelyErroredSecondsPLCP Counter, xldv20pmD3cFeSeverelyErroredSecondsPLCP Counter, xldv20pmD3cNeCodeViolationsP Counter, xldv20pmD3cNeCodeViolationsCP Counter, xldv20pmD3cFeCodeViolationsCP Counter, xldv20pmD3cNeCodeViolationsPLCP Counter, xldv20pmD3cFeCodeViolationsPLCP Counter, xldv20pmD3cNeUnavailableSeconds Counter, xldv20pmD3cFeUnavailableSeconds Counter, xldv20pmD3cNeUnavailableSecondsPLCP Counter, xldv20pmD3cFeUnavailableSecondsPLCP Counter, xldv20pmD3cNeSas Counter, xldv20pmD3cFeSas Counter } xldv20pmD3cIntervalType OBJECT-TYPE -- info-VALUE: min15(1), day(2) -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmIntervalType ACCESS read-only STATUS mandatory DESCRIPTION " This type attribute is used to select between the 15 min or the day accumulation types. " ::= { xldv20pmD3CurrentEntry 1 } xldv20pmD3cOAMLevel OBJECT-TYPE -- info-VALUE: 1..3 -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (1..3) ACCESS read-only STATUS mandatory DESCRIPTION " This attribute is used to select between the 3 OAM levels f1 (1), f2 (2) and f3 (3) . " ::= { xldv20pmD3CurrentEntry 2 } xldv20pmD3cAdminState OBJECT-TYPE -- info-VALUE: unlocked(1), locked(2) -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20AdminState ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute is used to activate (unlock) and deactivate (lock) the functions (incl. collection) performed by this managed entity. Note: the 15min collection object must be activated, before day collection can operate. " ::= { xldv20pmD3CurrentEntry 3 } xldv20pmD3cSuspectFlag OBJECT-TYPE -- info-VALUE: reliable(1), suspect(2) -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmSuspectType ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute will be set to indicate that troubles arose during an interval and that the counter values are suspect and incomplete. " ::= { xldv20pmD3CurrentEntry 4 } xldv20pmD3cHistEntrySize OBJECT-TYPE -- info-VALUE: 1..96 -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (1..96) ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute indicates the configured history size. The default value is 1 and means that at least one history entry is provided. " ::= { xldv20pmD3CurrentEntry 5 } xldv20pmD3cNrHistEntriesAvailable OBJECT-TYPE -- info-VALUE: 0..96 -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..96) ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute indicates how many history entries are already available. The range of values is between 0 and xldv20pmD3cHistEntrySize, thereby 0 means that this entry is not valid . " ::= { xldv20pmD3CurrentEntry 6 } xldv20pmD3cElapsedTime OBJECT-TYPE -- info-VALUE: 0..900 (sec) for min15 -- info-VALUE: 0..1440 (min) for day -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..1440) ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents the difference between the current time and the start of the present summary interval. Units are seconds when 15 minute interval is selected or minutes for day interval. (Note: accurate to the sample time interval). " ::= { xldv20pmD3CurrentEntry 7 } xldv20pmD3cThresholdLimitIndex OBJECT-TYPE -- info-VALUE: 1..30 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (1..30) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute provides an index to the ThresholdLimitTable managed entity that contains the threshold limits for the performance parameters reported by this managed entity. When the value of this attribute is set to 1, default threshold limits shall be used. These default values are not part of the threshold limit table but are hard coded in the application SW of PM. The range of values is [1,30]. " ::= { xldv20pmD3CurrentEntry 8 } xldv20pmD3cNeErroredSecondsCP OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of Errored Seconds (ES) within the current interval or current day, the generation thereof is based on CP-bit parity. Counter applicable for : d3n and F2 level only . " ::= { xldv20pmD3CurrentEntry 9 } xldv20pmD3cFeErroredSecondsCP OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of Errored Seconds (ES) within the current 15 minute interval or current day, the generation thereof is based on CP-bit parity . Counter applicable for : d3f and F2 level only . " ::= { xldv20pmD3CurrentEntry 10 } xldv20pmD3cNeErroredSecondsPLCP OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of Errored Seconds on PLCP-bit parity within the current 15 minute interval or current day. Counter applicable for : d3n and F3 level only . " ::= { xldv20pmD3CurrentEntry 11 } xldv20pmD3cFeErroredSecondsPLCP OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of Errored Seconds on PLCP-bit parity within the current 15 minute interval or current day. Counter applicable for : d3f and F3 level only . " ::= { xldv20pmD3CurrentEntry 12 } xldv20pmD3cNeSeverelyErroredSecondsCP OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of Severely Errored Seconds (SES) within the current 15 minute interval or current day based on CP-bit parity, the generation thereof is based on CP-bit parity. Counter applicable for : d3n and F2 level only . " ::= { xldv20pmD3CurrentEntry 13 } xldv20pmD3cFeSeverelyErroredSecondsCP OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of Severely Errored Seconds (SES) within the current 15 minute interval or current day, the generation thereof is based on CP-bit parity . Counter applicable for : d3f and F2 level only . " ::= { xldv20pmD3CurrentEntry 14 } xldv20pmD3cNeSeverelyErroredSecondsPLCP OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of Severely Errored Seconds (SES) within the current 15 minute interval or current day, the generation thereof is based on PLCP-bit parity . Counter applicable for : d3n and F3 level only . " ::= { xldv20pmD3CurrentEntry 15 } xldv20pmD3cFeSeverelyErroredSecondsPLCP OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of Severely Errored Seconds (SES) within the current 15 minute interval or current day, the generation thereof is based on PLCP-bit parity . Counter applicable for : d3f and F3 level only . " ::= { xldv20pmD3CurrentEntry 16 } xldv20pmD3cNeCodeViolationsP OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of Code Violations Errors (Count of P-bit parity errors) within the current 15 minute interval or current day. Counter applicable for : d3n and F2 level only . " ::= { xldv20pmD3CurrentEntry 17 } xldv20pmD3cNeCodeViolationsCP OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of Code Violations Errors (Count of CP-bit parity errors) within the current 15 minute interval or current day. Counter applicable for : d3n and F2 level only . " ::= { xldv20pmD3CurrentEntry 18 } xldv20pmD3cFeCodeViolationsCP OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of Code Violations Errors (Count of CP-bit parity errors) within the current 15 minute interval or current day. Counter applicable for : d3f and F2 level only . " ::= { xldv20pmD3CurrentEntry 19 } xldv20pmD3cNeCodeViolationsPLCP OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of Code Violations Errors (Count of PLCP frame Bit Interleaved Parity errors) within the current 15 minute interval or current day. Counter applicable for : d3n and F3 level only . " ::= { xldv20pmD3CurrentEntry 20 } xldv20pmD3cFeCodeViolationsPLCP OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of Code Violations Errors (Count of PLCP frame Bit Interleaved Parity errors) within the current 15 minute interval or current day. Counter applicable for : d3f and F3 level only . " ::= { xldv20pmD3CurrentEntry 21 } xldv20pmD3cNeUnavailableSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of Unavailable Seconds (UAS) within the current 15 minute interval or current day. Counter applicable for : d3n and F2 level only. " ::= { xldv20pmD3CurrentEntry 22 } xldv20pmD3cFeUnavailableSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of Unavailable Seconds (UAS) within the current 15 minute interval or current day. Counter applicable for : d3f and F2 level only . " ::= { xldv20pmD3CurrentEntry 23 } xldv20pmD3cNeUnavailableSecondsPLCP OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of Unavailable Seconds (UAS) within the current 15 minute interval or current day. The generation is based on PLCP-bit parity. Counter applicable for : d3n and F3 level only . " ::= { xldv20pmD3CurrentEntry 24 } xldv20pmD3cFeUnavailableSecondsPLCP OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of Unavailable Seconds (UAS) within the current 15 minute interval or current day. The generation is based on PLCP-bit parity. Counter applicable for : d3f and F3 level only . " ::= { xldv20pmD3CurrentEntry 25 } xldv20pmD3cNeSas OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of one second intervals containing one ore more Severely Errored Frame (SEF) defects or one or more Alarm Indication Signal (AIS) defects within the current 15 minute interval or current day. Counter applicable for : d3n and F2 level only . " ::= { xldv20pmD3CurrentEntry 26 } xldv20pmD3cFeSas OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of one second intervals containing one ore more Severely Errored Frame (SEF) defects or one or more Alarm Indication Signal (AIS) defects within the current 15 minute interval or current day. Counter applicable for : d3f and F2 level only . " ::= { xldv20pmD3CurrentEntry 27 } -- -------------------------------------------------------------- -- PMo D S 3 H i s t o r y D a t a Table -- -------------------------------------------------------------- xldv20pmD3HistoryTable OBJECT-TYPE -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX SEQUENCE OF Xldv20pmD3HistoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " This table contains the entries for the PMo history objects at the near-end and far-end DS3 interfaces. It contains results that are overtaken from the D3CurrentTable PM-object at the end of a 15 min /day interval . " --DEFAULT next-function-async fsnPmD3hEntryNext --DEFAULT get-function-async fsnPmD3hEntryGet ::= { xldv20pmPerformanceMonitoring 7 } xldv20pmD3HistoryEntry OBJECT-TYPE -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmD3HistoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " An entry describing the DS3 near-end and far-end History Data Table . " INDEX { xldv20IfIndex, xldv20pmD3hIntervalType, xldv20pmD3hOAMLevel, xldv20pmD3hHistEntryNr } ::= { xldv20pmD3HistoryTable 1 } Xldv20pmD3HistoryEntry ::= SEQUENCE { xldv20pmD3hIntervalType Xldv20pmIntervalType, xldv20pmD3hOAMLevel INTEGER, xldv20pmD3hHistEntryNr INTEGER, xldv20pmD3hSuspectFlag Xldv20pmSuspectType, xldv20pmD3hPeriodEndTime INTEGER, xldv20pmD3hNeErroredSecondsCP Counter, xldv20pmD3hFeErroredSecondsCP Counter, xldv20pmD3hNeErroredSecondsPLCP Counter, xldv20pmD3hFeErroredSecondsPLCP Counter, xldv20pmD3hNeSeverelyErroredSecondsCP Counter, xldv20pmD3hFeSeverelyErroredSecondsCP Counter, xldv20pmD3hNeSeverelyErroredSecondsPLCP Counter, xldv20pmD3hFeSeverelyErroredSecondsPLCP Counter, xldv20pmD3hNeCodeViolationsP Counter, xldv20pmD3hNeCodeViolationsCP Counter, xldv20pmD3hFeCodeViolationsCP Counter, xldv20pmD3hNeCodeViolationsPLCP Counter, xldv20pmD3hFeCodeViolationsPLCP Counter, xldv20pmD3hNeUnavailableSeconds Counter, xldv20pmD3hFeUnavailableSeconds Counter, xldv20pmD3hNeUnavailableSecondsPLCP Counter, xldv20pmD3hFeUnavailableSecondsPLCP Counter, xldv20pmD3hNeSas Counter, xldv20pmD3hFeSas Counter } xldv20pmD3hIntervalType OBJECT-TYPE -- info-VALUE: min15(1), day(2) -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmIntervalType ACCESS read-only STATUS mandatory DESCRIPTION " This type attribute is used to select between the 15 min or the day accumulation types. " ::= { xldv20pmD3HistoryEntry 1 } xldv20pmD3hOAMLevel OBJECT-TYPE -- info-VALUE: 1..3 -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (1..3) ACCESS read-only STATUS mandatory DESCRIPTION " This attribute is used to select between the 3 OAM levels f1 (1), f2 (2) and f3 (3) . " ::= { xldv20pmD3HistoryEntry 2 } xldv20pmD3hHistEntryNr OBJECT-TYPE -- info-VALUE: 1..96 -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (1..96) ACCESS read-only STATUS mandatory DESCRIPTION " This attribute is used as index to address a history entry. Entry 1 is the most recent, entry 96 is 24 hours ago. The range of values is between 1 and xldv20pmD3cHistEntrySize . " ::= { xldv20pmD3HistoryEntry 3 } xldv20pmD3hSuspectFlag OBJECT-TYPE -- info-VALUE: reliable(1), suspect(2) -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmSuspectType ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute will be set to indicate that troubles arose during an interval and that the counter values are suspect and incomplete. " ::= { xldv20pmD3HistoryEntry 4 } xldv20pmD3hPeriodEndTime OBJECT-TYPE -- info-VALUE: 0..2147483647 -- info-ROU: GET SET [db,pm] -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER(0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute is a record of date/time at the end of an interval . " ::= { xldv20pmD3HistoryEntry 5 } xldv20pmD3hNeErroredSecondsCP OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a set of history counter of Errored Seconds (ES), the generation thereof is based on CP-bit parity for a 15min /day interval. Counter applicable for : d3n and F2 level only . " ::= { xldv20pmD3HistoryEntry 6 } xldv20pmD3hFeErroredSecondsCP OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a set of history counter of Errored Seconds (ES), the generation thereof is based on CP-bit parity for a 15min /day interval. Counter applicable for : d3f and F2 level only . " ::= { xldv20pmD3HistoryEntry 7 } xldv20pmD3hNeErroredSecondsPLCP OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a set of history counter of Errored Seconds (ES) (One second interval in which Code Violations errors occure) for a 15min /day interval. Counter applicable for : d3n and F3 level only . " ::= { xldv20pmD3HistoryEntry 8 } xldv20pmD3hFeErroredSecondsPLCP OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a set of history counter of Errored Seconds (ES) (One second interval in which Code Violations errors occure) for a 15min /day interval. Counter applicable for : d3f and F3 level only . " ::= { xldv20pmD3HistoryEntry 9 } xldv20pmD3hNeSeverelyErroredSecondsCP OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a set of history counter of Severely Errored Seconds (ES), the generation thereof is based on CP-bit parity for a 15min /day interval. Counter applicable for : d3n and F2 level only . " ::= { xldv20pmD3HistoryEntry 10 } xldv20pmD3hFeSeverelyErroredSecondsCP OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a set of history counter of Severely Errored Seconds (ES), the generation thereof is based on CP-bit parity for a 15min /day interval. Counter applicable for : d3f and F2 level only . " ::= { xldv20pmD3HistoryEntry 11 } xldv20pmD3hNeSeverelyErroredSecondsPLCP OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a set of history counter of Severely Errored Seconds (SES) for a 15min / day interval. Counter applicable for : d3n and F3 level only . " ::= { xldv20pmD3HistoryEntry 12 } xldv20pmD3hFeSeverelyErroredSecondsPLCP OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a set of history counter of Severely Errored Seconds (SES) for a 15min / day interval. Counter applicable for : d3f and F3 level only . " ::= { xldv20pmD3HistoryEntry 13 } xldv20pmD3hNeCodeViolationsP OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of Code Violations Errors (Count of P-bit parity errors) for a 15 min /day interval. Counter applicable for : d3n and F2 level only. " ::= { xldv20pmD3HistoryEntry 14 } xldv20pmD3hNeCodeViolationsCP OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a set of history counter of Code Violations Errors (Count of CP-bit parity errors) for a 15min /day interval. Counter applicable for : d3n and F2 level only . " ::= { xldv20pmD3HistoryEntry 15 } xldv20pmD3hFeCodeViolationsCP OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a set of history counter of Code Violations Errors (Count of CP-bit parity errors) for a 15min /day interval. Counter applicable for : d3f and F2 level only . " ::= { xldv20pmD3HistoryEntry 16 } xldv20pmD3hNeCodeViolationsPLCP OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a set of history counter of Code Violations Errors (Count of PLCP frame Bit Interleaved Parity errors) for a 15min /day interval. Counter applicable for : d3n and F3 level only . " ::= { xldv20pmD3HistoryEntry 17 } xldv20pmD3hFeCodeViolationsPLCP OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a set of history counter of Code Violations Errors (Count of PLCP frame Bit Interleaved Parity errors) for a 15min /day interval. Counter applicable for : d3f and F3 level only . " ::= { xldv20pmD3HistoryEntry 18 } xldv20pmD3hNeUnavailableSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a set of history counter of Unavailable Seconds (UAS) for a 15min /day interval. Counter applicable for : d3n and F2 level only . " ::= { xldv20pmD3HistoryEntry 19 } xldv20pmD3hFeUnavailableSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a set of history counter of Unavailable Seconds (UAS) for a 15min /day interval. Counter applicable for : d3f and F2 level only . " ::= { xldv20pmD3HistoryEntry 20 } xldv20pmD3hNeUnavailableSecondsPLCP OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a set of history counter of Unavailable Seconds (UAS) for a 15min /day interval. Counter applicable for : d3n and F3 level only . " ::= { xldv20pmD3HistoryEntry 21 } xldv20pmD3hFeUnavailableSecondsPLCP OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a set of history counter of Unavailable Seconds (UAS) for a 15min /day interval. Counter applicable for : d3f and F3 level only . " ::= { xldv20pmD3HistoryEntry 22 } xldv20pmD3hNeSas OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a set of history counter of one second intervals containing one ore more Severely Errored Frame (SEF) defects or one or more Alarm Indication Signal (AIS) defects for a 15min /day interval. Counter applicable for : d3n and F2 level only . " ::= { xldv20pmD3HistoryEntry 23 } xldv20pmD3hFeSas OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a set of history counter of one second intervals containing one ore more Severely Errored Frame (SEF) defects or one or more Alarm Indication Signal (AIS) defects for a 15min /day interval. Counter applicable for : d3f and F2 level only . " ::= { xldv20pmD3HistoryEntry 24 } -- -------------------------------------------------------------- -- Pmo S T M 1 C u r r e n t D a t a Table -- -------------------------------------------------------------- xldv20pmS1CurrentTable OBJECT-TYPE -- info-IMPL: V2.0-> SYNTAX SEQUENCE OF Xldv20pmS1CurrentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " This table contains the entries for the current 15 minute interval or the current day for STM1 near-end and far-end PPTPs. Note: Day PM collection uses the 15min interval results . " --DEFAULT test-function-async fsnPmS1cEntryTest --DEFAULT next-function-async fsnPmS1cEntryNext --DEFAULT set-function-async fsnPmS1cEntrySet --DEFAULT get-function-async fsnPmS1cEntryGet ::= { xldv20pmPerformanceMonitoring 8 } xldv20pmS1CurrentEntry OBJECT-TYPE -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmS1CurrentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " An entry describing the Stm1 Current Data Table . " INDEX { xldv20IfIndex, xldv20pmS1cIntervalType, xldv20pmS1cOAMLevel } ::= { xldv20pmS1CurrentTable 1 } Xldv20pmS1CurrentEntry ::= SEQUENCE { xldv20pmS1cIntervalType Xldv20pmIntervalType, xldv20pmS1cOAMLevel INTEGER, xldv20pmS1cAdminState Xldv20AdminState, xldv20pmS1cSuspectFlag Xldv20pmSuspectType, xldv20pmS1cHistEntrySize INTEGER, xldv20pmS1cNrHistEntriesAvailable INTEGER, xldv20pmS1cElapsedTime INTEGER, xldv20pmS1cThresholdLimitIndex INTEGER, xldv20pmS1cNeErroredSeconds Counter, xldv20pmS1cFeErroredSeconds Counter, xldv20pmS1cNeSeverelyErroredSeconds Counter, xldv20pmS1cFeSeverelyErroredSeconds Counter, xldv20pmS1cNeBackgroundBlockErrors Counter, xldv20pmS1cFeBackgroundBlockErrors Counter, xldv20pmS1cNeUnavailableSeconds Counter, xldv20pmS1cFeUnavailableSeconds Counter, xldv20pmS1cNeOfsSeconds Counter, xldv20pmS1cNeAisSeconds Counter, xldv20pmS1cNeLosSeconds Counter } xldv20pmS1cIntervalType OBJECT-TYPE -- info-VALUE: min15(1), day(2) -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmIntervalType ACCESS read-only STATUS mandatory DESCRIPTION " This type attribute is used to select between the 15 min or the day accumulation types. " ::= { xldv20pmS1CurrentEntry 1 } xldv20pmS1cOAMLevel OBJECT-TYPE -- info-VALUE: 1..3 -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (1..3) ACCESS read-only STATUS mandatory DESCRIPTION " This attribute is used to select between the 3 OAM levels f1 (1), f2 (2) and f3 (3) . " ::= { xldv20pmS1CurrentEntry 2 } xldv20pmS1cAdminState OBJECT-TYPE -- info-VALUE: unlocked(1), locked(2) -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20AdminState ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute is used to activate (unlock) and deactivate (lock) the functions (incl. collection) performed by this managed entity. Note: the 15min collection object must be activated, before day collection can operate. " ::= { xldv20pmS1CurrentEntry 3 } xldv20pmS1cSuspectFlag OBJECT-TYPE -- info-VALUE: reliable(1), suspect(2) -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmSuspectType ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute will be set to indicate that troubles arose during an interval and that the counter values are suspect and incomplete. " ::= { xldv20pmS1CurrentEntry 4 } xldv20pmS1cHistEntrySize OBJECT-TYPE -- info-VALUE: 1..96 -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (1..96) ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute indicates the configured history size. The default value is 1 and means that at least one history entry is provided. " ::= { xldv20pmS1CurrentEntry 5 } xldv20pmS1cNrHistEntriesAvailable OBJECT-TYPE -- info-VALUE: 0..96 -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..96) ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute indicates how many history entries are already available. The range of values is between 0 and xldv20pmS1cHistEntrySize, thereby 0 means that this entry is not valid . " ::= { xldv20pmS1CurrentEntry 6 } xldv20pmS1cElapsedTime OBJECT-TYPE -- info-VALUE: 0..900 (sec) for min15, -- info-VALUE: 0..1440 (min) for day -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER(0..1440) ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents the difference between the current time and the start of the present summary interval. Units are seconds when 15 minute interval is selected or minutes for day interval. (Note: accurate to the sample time interval). " ::= { xldv20pmS1CurrentEntry 7 } xldv20pmS1cThresholdLimitIndex OBJECT-TYPE -- info-VALUE: 1..30 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (1..30) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute provides an index to the ThresholdLimitTable managed entity that contains the threshold limits for the performance parameters reported by this managed entity. When the value of this attribute is set to 1, default threshold limits shall be used. These default values are not part of the threshold limit table but are hard coded in the application SW of PM. " ::= { xldv20pmS1CurrentEntry 8 } xldv20pmS1cNeErroredSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of Errored Seconds (ES) within the current 15 minute interval or current day. Counter applicable for : s1n and F1, F2, F3 levels . " ::= { xldv20pmS1CurrentEntry 9 } xldv20pmS1cFeErroredSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of Errored Seconds (ES) within the current 15 minute interval or current day. Counter applicable for : s1f and F2 and F3 levels . " ::= { xldv20pmS1CurrentEntry 10 } xldv20pmS1cNeSeverelyErroredSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of Severely Errored Seconds (SES) within the current 15 minute interval or current day. Counter applicable for : s1n and F1, F2, F3 levels . " ::= { xldv20pmS1CurrentEntry 11 } xldv20pmS1cFeSeverelyErroredSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of Severely Errored Seconds (SES) within the current 15 minute interval or current day. Counter applicable for : s1f and F2 and F3 levels . " ::= { xldv20pmS1CurrentEntry 12 } xldv20pmS1cNeBackgroundBlockErrors OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter for Background Block Errors (BBE) within the current 15 minute interval or current day. Counter applicable for : s1n and F1, F2, F3 levels . " ::= { xldv20pmS1CurrentEntry 13 } xldv20pmS1cFeBackgroundBlockErrors OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter for Background Block Errors (BBE) within the current 15 minute interval or current day. Counter applicable for : s1f and F2 and F3 levels . " ::= { xldv20pmS1CurrentEntry 14 } xldv20pmS1cNeUnavailableSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of Unavailable Seconds (UAS) within the current 15 minute interval or current day. Counter applicable for : s1n and F1, F2, F3 levels . " ::= { xldv20pmS1CurrentEntry 15 } xldv20pmS1cFeUnavailableSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of Unavailable Seconds (UAS) within the current 15 minute interval or current day. Counter applicable for : s1f and F2 and F3 levels . " ::= { xldv20pmS1CurrentEntry 16 } xldv20pmS1cNeOfsSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of Errored Seconds on defect OFS within the current 15 minute interval or current day. Counter applicable for : s1n and level F1 . " ::= { xldv20pmS1CurrentEntry 17 } xldv20pmS1cNeAisSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of errored Seconds on defect alarm indicatin signal AIS for a 15 min /day interval. Counter applicable for : s1n and F2 . " ::= { xldv20pmS1CurrentEntry 18 } xldv20pmS1cNeLosSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of errored Seconds on defect LOS within the current 15 minute interval or current day. Counter applicable for : s1n and level F1. " ::= { xldv20pmS1CurrentEntry 19 } -- -------------------------------------------------------------- -- PMo S T M 1 H i s t o r y D a t a Table -- -------------------------------------------------------------- xldv20pmS1HistoryTable OBJECT-TYPE -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX SEQUENCE OF Xldv20pmS1HistoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " This table contains the entries for the PMo objects of the 15 min /one day-history data collection results at the respective stm1 (s1n, s1f) drop area interfaces . " --DEFAULT next-function-async fsnPmS1hEntryNext --DEFAULT get-function-async fsnPmS1hEntryGet ::= { xldv20pmPerformanceMonitoring 9 } xldv20pmS1HistoryEntry OBJECT-TYPE -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmS1HistoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " An entry describing the S1 History Data Table . " INDEX { xldv20IfIndex, xldv20pmS1hIntervalType, xldv20pmS1hOAMLevel, xldv20pmS1hHistEntryNr } ::= { xldv20pmS1HistoryTable 1 } Xldv20pmS1HistoryEntry ::= SEQUENCE { xldv20pmS1hIntervalType Xldv20pmIntervalType, xldv20pmS1hOAMLevel INTEGER, xldv20pmS1hHistEntryNr INTEGER, xldv20pmS1hSuspectFlag Xldv20pmSuspectType, xldv20pmS1hPeriodEndTime INTEGER, xldv20pmS1hNeErroredSeconds Counter, xldv20pmS1hFeErroredSeconds Counter, xldv20pmS1hNeSeverelyErroredSeconds Counter, xldv20pmS1hFeSeverelyErroredSeconds Counter, xldv20pmS1hNeBackgroundBlockErrors Counter, xldv20pmS1hFeBackgroundBlockErrors Counter, xldv20pmS1hNeUnavailableSeconds Counter, xldv20pmS1hFeUnavailableSeconds Counter, xldv20pmS1hNeOfsSeconds Counter, xldv20pmS1hNeAisSeconds Counter, xldv20pmS1hNeLosSeconds Counter } xldv20pmS1hIntervalType OBJECT-TYPE -- info-VALUE: min15(1), day(2) -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmIntervalType ACCESS read-only STATUS mandatory DESCRIPTION " This type attribute is used to select between the 15 min or the day accumulation types. " ::= { xldv20pmS1HistoryEntry 1 } xldv20pmS1hOAMLevel OBJECT-TYPE -- info-VALUE: 1..3 -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (1..3) ACCESS read-only STATUS mandatory DESCRIPTION " This attribute is used to select between the 3 OAM levels f1 (1), f2 (2) and f3 (3) . " ::= { xldv20pmS1HistoryEntry 2 } xldv20pmS1hHistEntryNr OBJECT-TYPE -- info-VALUE: 1..96 -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (1..96) ACCESS read-only STATUS mandatory DESCRIPTION " This attribute is used as index to address a history entry. Entry 1 is the most recent, entry 96 is 24 hours ago. The range of values is between 1 and xldv20pmCcHistEntrySize . " ::= { xldv20pmS1HistoryEntry 3 } xldv20pmS1hSuspectFlag OBJECT-TYPE -- info-VALUE: reliable(1), suspect(2) -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmSuspectType ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute will be set to indicate that troubles arose during an interval and that the counter values are suspect and incomplete. " ::= { xldv20pmS1HistoryEntry 4 } xldv20pmS1hPeriodEndTime OBJECT-TYPE -- info-VALUE: 0..2147483647 -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER(0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION " Date/time at the end of the selected interval. " ::= { xldv20pmS1HistoryEntry 5 } xldv20pmS1hNeErroredSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of Errored Seconds (ES) over a 15 min /day interval. Counter applicable for : s1n and F1, F2, F3 levels . " ::= { xldv20pmS1HistoryEntry 6 } xldv20pmS1hFeErroredSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of Errored Seconds (ES) over a 15 min /day interval. Counter applicable for : s1f and F2 and F3 levels . " ::= { xldv20pmS1HistoryEntry 7 } xldv20pmS1hNeSeverelyErroredSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of Severely Errored Seconds (SES) over a 15 min /day interval. Counter applicable for : s1n and F1, F2, F3 levels . " ::= { xldv20pmS1HistoryEntry 8 } xldv20pmS1hFeSeverelyErroredSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of Severely Errored Seconds (SES) over a 15 min /day interval. Counter applicable for : s1f and F2 and F3 levels . " ::= { xldv20pmS1HistoryEntry 9 } xldv20pmS1hNeBackgroundBlockErrors OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter for Background Block Errors (BBE) over a 15 min /day interval. Counter applicable for : s1n and F1, F2, F3 levels . " ::= { xldv20pmS1HistoryEntry 10 } xldv20pmS1hFeBackgroundBlockErrors OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter for Background Block Errors (BBE) over a 15 min /day interval. Counter applicable for : s1f and F2 and F3 levels . " ::= { xldv20pmS1HistoryEntry 11 } xldv20pmS1hNeUnavailableSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of Unavailable Seconds (UAS) for a 15 min /day interval. Counter applicable for : s1n and F1, F2, F3 levels . " ::= { xldv20pmS1HistoryEntry 12 } xldv20pmS1hFeUnavailableSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of Unavailable Seconds (UAS) for a 15 min /day interval. Counter applicable for : s1f and F2 and F3 levels . " ::= { xldv20pmS1HistoryEntry 13 } xldv20pmS1hNeOfsSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of Errored Seconds on defect OFS for a 15 min /day interval. Counter applicable for : s1n and level F1 . " ::= { xldv20pmS1HistoryEntry 14 } xldv20pmS1hNeAisSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of errored Seconds on defect alarm indicatin signal AIS for a 15 min /day interval. Counter applicable for : s1n and level F2 . " ::= { xldv20pmS1HistoryEntry 15 } xldv20pmS1hNeLosSeconds OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of errored Seconds on defect LOS for a 15 min /day interval. Counter applicable for : s1n and F1 . " ::= { xldv20pmS1HistoryEntry 16 } -- -------------------------------------------------------------- -- PMo o n A T M L a y e r -- -- A t m O b j e c t s T a b l e -- ------------------------------------------------------------------ -- -- -------------------------------------------------------------- -- PMo events -- ------------------------------------------------------------------ xldv20pmAtmObjectsTable OBJECT-TYPE -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX SEQUENCE OF Xldv20pmAtmObjectsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " This table contains the entries for the PMo objects on ATM layer. Maximum of monitored connections is 128. " --DEFAULT test-function-async fsnPmAoEntryTest --DEFAULT next-function-async fsnPmAoEntryNext --DEFAULT set-function-async fsnPmAoEntrySet --DEFAULT get-function-async fsnPmAoEntryGet ::= { xldv20pmPerformanceMonitoring 10 } xldv20pmAtmObjectsEntry OBJECT-TYPE -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmAtmObjectsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " An entry of the xldv20pmAtmObjectsTable. " INDEX { xldv20pmAoIndex } ::= { xldv20pmAtmObjectsTable 1 } Xldv20pmAtmObjectsEntry ::= SEQUENCE { xldv20pmAoIndex INTEGER , xldv20pmAoFlowType Xldv20pmFlowType, xldv20pmAoAdminState Xldv20AdminState, xldv20pmAoBlockSize Xldv20pmBlockSizeType } xldv20pmAoIndex OBJECT-TYPE -- info-VALUE: 1..128 -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (1..128) ACCESS read-only STATUS mandatory DESCRIPTION " Identifies an entry of the xldv20pmAtmObjectsTable. " ::= { xldv20pmAtmObjectsEntry 1 } xldv20pmAoFlowType OBJECT-TYPE -- info-VALUE: f4Segment(1), f4EndToEnd(2) -- info-VALUE: f5Segment(3), f5EndToEnd(4) -- info-ROU: GET db SET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmFlowType ACCESS read-only STATUS mandatory DESCRIPTION " This attribute identifies the flow type : F4 (VP) or F5 (VC) segment or endToEnd flow. " ::= { xldv20pmAtmObjectsEntry 2 } xldv20pmAoAdminState OBJECT-TYPE -- info-VALUE: unlocked(1), locked(2) -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20AdminState ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute is used to activate (unlock) and deactivate (lock) the functions (incl. collection) performed by this managed entity. Note: the 15min collection object must be activated, before day collection can operate. " ::= { xldv20pmAtmObjectsEntry 3 } xldv20pmAoBlockSize OBJECT-TYPE -- info-VALUE: 128 (default), 256, 512, 1024 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmBlockSizeType ACCESS read-write STATUS mandatory DESCRIPTION " This is the number of user cells after which PMo cell is inserted. Default is 128. " ::= { xldv20pmAtmObjectsEntry 4 } -- -------------------------------------------------------------- -- -------------------------------------------------------------- -- PMo o n A T M L a y e r -- -- A t m E n d p o i n t s T a b l e -- -------------------------------------------------------------- xldv20pmAtmEndpointsTable OBJECT-TYPE -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX SEQUENCE OF Xldv20pmAtmEndpointsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " This table contains the enpoints for PMo on Atm layer. " --DEFAULT next-function-async fsnPmAeEntryNext --DEFAULT get-function-async fsnPmAeEntryGet ::= { xldv20pmPerformanceMonitoring 11 } xldv20pmAtmEndpointsEntry OBJECT-TYPE -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmAtmEndpointsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " An entry of xldv20pmAtmEndpointsTable. " INDEX { xldv20pmAoIndex, xldv20pmAeEndpointType } ::= { xldv20pmAtmEndpointsTable 1 } Xldv20pmAtmEndpointsEntry ::= SEQUENCE { xldv20pmAeEndpointType Xldv20pmEndpointType, xldv20pmAeConnectionIndex INTEGER, xldv20pmAeConnectionIndexType Xldv20pmConnectionIndexType, xldv20pmAeRole Xldv20pmRoleType, xldv20pmAeFlowDirection Xldv20FlowDirection } xldv20pmAeEndpointType OBJECT-TYPE -- info-VALUE: source(1), sink(2) -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmEndpointType ACCESS read-only STATUS mandatory DESCRIPTION " Identifies the type of endpoint. " ::= { xldv20pmAtmEndpointsEntry 1 } xldv20pmAeConnectionIndex OBJECT-TYPE -- info-VALUE: 1..2048 -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (1..2048) ACCESS read-only STATUS mandatory DESCRIPTION " This attribute identifies the Vpl or Vcl cross connection where an endpoint object should be added. " ::= { xldv20pmAtmEndpointsEntry 2 } xldv20pmAeConnectionIndexType OBJECT-TYPE -- info-VALUE: vplUni(1),vplNni(2),vclUni(3),vclNni(4) -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmConnectionIndexType ACCESS read-only STATUS mandatory DESCRIPTION " This attribute identifies the type of connection index and the termination point where an endpoint should be added. " ::= { xldv20pmAtmEndpointsEntry 3 } xldv20pmAeRole OBJECT-TYPE -- info-VALUE: analyseWithBackwardReporting(1), -- info-VALUE: analyseWithoutBackwardReporting(2), -- info-VALUE: generateWithCollect(3), generateWithoutCollect(4)} -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmRoleType ACCESS read-only STATUS mandatory DESCRIPTION " The role of endpoint. 'analyseWithBackwardReporting' (sink) means extracting forward monitoring (FM) OAM cells, sending back backward reporting OAM cells and no data collection for current and history table. 'analyseWithoutBackwardReporting' (sink) means extracting FM cells and also collecting data. 'generateWithCollect' (source) means inserting FM cells, extracting backward reporting cells if they arrive and collect data for current and history table. 'generateWithoutCollect' (source) means inserting FM cells but without collecting data. The CMU, the Ethernet part of the Twin NT can be inserting and extracting points. " ::= { xldv20pmAtmEndpointsEntry 4 } xldv20pmAeFlowDirection OBJECT-TYPE -- info-VALUE: inwards(2), outwards(3) -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20FlowDirection ACCESS read-only STATUS mandatory DESCRIPTION " This attribute identifies the flow direction. inwards means flow direction from outside (external interface) to cross connection. outwards means flow direction from inside to external interface. " ::= { xldv20pmAtmEndpointsEntry 5 } -- -------------------------------------------------------------- -- PMo A T M C u r r e n t Table -- -------------------------------------------------------------- xldv20pmAtmCurrentTable OBJECT-TYPE -- info-IMPL: V2.0-> SYNTAX SEQUENCE OF Xldv20pmAtmCurrentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " This table contains the entries for the the PMo objects for the current data of Pmo monitoring objects on ATM layer. It includes attributes for performance parameters, collection interval is 15 minutes and one day . " --DEFAULT test-function-async fsnPmAcEntryTest --DEFAULT next-function-async fsnPmAcEntryNext --DEFAULT set-function-async fsnPmAcEntrySet --DEFAULT get-function-async fsnPmAcEntryGet ::= { xldv20pmPerformanceMonitoring 12 } xldv20pmAtmCurrentEntry OBJECT-TYPE -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmAtmCurrentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " An entry describing the Atm Current Data Table . " INDEX { xldv20pmAoIndex, xldv20pmAcIntervalType } ::= { xldv20pmAtmCurrentTable 1 } Xldv20pmAtmCurrentEntry ::= SEQUENCE { xldv20pmAcIntervalType Xldv20pmIntervalType, xldv20pmAcAdminState Xldv20AdminState, xldv20pmAcSuspectFlag Xldv20pmSuspectType, xldv20pmAcHistEntrySize INTEGER, xldv20pmAcNrHistEntriesAvailable INTEGER, xldv20pmAcElapsedTime INTEGER, xldv20pmAcThresholdLimitIndex INTEGER, xldv20pmAcTransmittedUserCells Counter, xldv20pmAcLostUserCells Counter, xldv20pmAcMisinsertedUserCells Counter } xldv20pmAcIntervalType OBJECT-TYPE -- info-VALUE: min15(1), day(2) -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmIntervalType ACCESS read-only STATUS mandatory DESCRIPTION " This type attribute is used to select between the 15 min or the day accumulation types. " ::= { xldv20pmAtmCurrentEntry 1 } xldv20pmAcAdminState OBJECT-TYPE -- info-VALUE: unlocked(1), locked(2) -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20AdminState ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute is used to activate (unlock) and deactivate (lock) the functions (incl. collection) performed by this managed entity. Note: the 15min collection object must be activated, before day collection can operate. " ::= { xldv20pmAtmCurrentEntry 2 } xldv20pmAcSuspectFlag OBJECT-TYPE -- info-VALUE: reliable(1), suspect(2) -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmSuspectType ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute will be set to indicate that troubles arose during an interval and that the counter values are suspect and incomplete. " ::= { xldv20pmAtmCurrentEntry 3 } xldv20pmAcHistEntrySize OBJECT-TYPE -- info-VALUE: 1..96 (default 1) -- info-VALUE: day counter : 1. min15 counter: 1..96 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (1..96) ACCESS read-only STATUS mandatory DESCRIPTION " This is the configured size of history. " ::= { xldv20pmAtmCurrentEntry 4 } xldv20pmAcNrHistEntriesAvailable OBJECT-TYPE -- info-VALUE: day counter : 0,1.min15 counter: 0..96 (default 0) -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..96) ACCESS read-only STATUS mandatory DESCRIPTION " This is the number of history entries which are available in the history table. " ::= { xldv20pmAtmCurrentEntry 5 } xldv20pmAcElapsedTime OBJECT-TYPE -- info-VALUE: 0..900 (sec) for min15, -- info-VALUE: 0..1440 (min) for day -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER(0..1440) ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents the difference between the current time and the start of the present summary interval. Units are seconds when 15 minute interval is selected or minutes for day interval. (Note: accurate to the sample time interval). " ::= { xldv20pmAtmCurrentEntry 6 } xldv20pmAcThresholdLimitIndex OBJECT-TYPE -- info-VALUE: 1..30 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (1..30) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute provides an index to the ThresholdLimitTable managed entity that contains the threshold limits for the performance parameters reported by this managed entity. When the value of this attribute is set to 1, default threshold limits shall be used . " ::= { xldv20pmAtmCurrentEntry 7 } xldv20pmAcTransmittedUserCells OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of transmitted user cells for a 15 min /day interval. " ::= { xldv20pmAtmCurrentEntry 8 } xldv20pmAcLostUserCells OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of lost user cells for a 15 min /day interval. " ::= { xldv20pmAtmCurrentEntry 9 } xldv20pmAcMisinsertedUserCells OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of Misinserted user cells for a 15 min /day interval. " ::= { xldv20pmAtmCurrentEntry 10 } -- -------------------------------------------------------------- -- PMo A T M H I S T O R Y Table -- -------------------------------------------------------------- xldv20pmAtmHistoryTable OBJECT-TYPE -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX SEQUENCE OF Xldv20pmAtmHistoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " This table contains the entries for the 15 min /one day-history data collection results for PMo objects of ATM layer. " --DEFAULT next-function-async fsnPmAhEntryNext --DEFAULT get-function-async fsnPmAhEntryGet ::= { xldv20pmPerformanceMonitoring 13 } xldv20pmAtmHistoryEntry OBJECT-TYPE -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmAtmHistoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " An entry describing the History Data Table for PMo on ATM layer. " INDEX { xldv20pmAoIndex, xldv20pmAhIntervalType, xldv20pmAhHistEntryNr } ::= { xldv20pmAtmHistoryTable 1 } Xldv20pmAtmHistoryEntry ::= SEQUENCE { xldv20pmAhIntervalType Xldv20pmIntervalType, xldv20pmAhHistEntryNr INTEGER, xldv20pmAhSuspectFlag Xldv20pmSuspectType, xldv20pmAhPeriodEndTime INTEGER, xldv20pmAhTransmittedUserCells Counter, xldv20pmAhLostUserCells Counter, xldv20pmAhMisinsertedUserCells Counter } xldv20pmAhIntervalType OBJECT-TYPE -- info-VALUE: min15(1), day(2) -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmIntervalType ACCESS read-only STATUS mandatory DESCRIPTION " This type attribute is used to select between the 15 min or the day accumulation types. " ::= { xldv20pmAtmHistoryEntry 1 } xldv20pmAhHistEntryNr OBJECT-TYPE -- info-VALUE: 1..96 -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (1..96) ACCESS read-only STATUS mandatory DESCRIPTION " This attribute is used as index to address a history entry. Entry 1 is the most recent, entry 96 is 24 hours ago. The range of values is between 1 and xldv20pmAcHistEntrySize . " ::= { xldv20pmAtmHistoryEntry 2 } xldv20pmAhSuspectFlag OBJECT-TYPE -- info-VALUE: reliable(1), suspect(2) -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmSuspectType ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute will be set to indicate that troubles arose during an interval and that the counter values are suspect and incomplete. " ::= { xldv20pmAtmHistoryEntry 3 } xldv20pmAhPeriodEndTime OBJECT-TYPE -- info-VALUE: 0..2147483647 -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER(0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION " Date/time at the end of the selected interval. " ::= { xldv20pmAtmHistoryEntry 4 } xldv20pmAhTransmittedUserCells OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of transmitted user cells for a 15 min /day interval. " ::= { xldv20pmAtmHistoryEntry 5 } xldv20pmAhLostUserCells OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of lost user cells for a 15 min /day interval. " ::= { xldv20pmAtmHistoryEntry 6 } xldv20pmAhMisinsertedUserCells OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of Misinserted user cells for a 15 min /day interval. " ::= { xldv20pmAtmHistoryEntry 7 } -- -------------------------------------------------------------- -- PMo The IMA Group Current Statistics subtree -- -------------------------------------------------------------- -- -- -- The IMA Group Current Statistics subtree consists of a single table: -- the IMA Group Current Table. -- -- Selection of xldv20pmImaGroupIntervalType min15 : -- The entries contain the cumulative sum -- collected by each IMA group for the current 15 minute interval. -- -- Selection of xldv20pmImaGroupIntervalType day : -- The entries contain the cumulative sum -- of the various statistics collected by each IMA group for the 24 hour -- period preceding the current interval -- xldv20pmImaGroupCurrentTable OBJECT-TYPE -- info-IMPL: V2.0-> SYNTAX SEQUENCE OF Xldv20pmImaGroupCurrentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " This table contains the entries for the PMo objects for the current data of Pmo monitoring objects for IMA groups . Collection interval is the current 15 minute and one the current day . " --DEFAULT test-function-async fsnPmIgcEntryTest --DEFAULT next-function-async fsnPmIgcEntryNext --DEFAULT set-function-async fsnPmIgcEntrySet --DEFAULT get-function-async fsnPmIgcEntryGet ::= { xldv20pmPerformanceMonitoring 14 } xldv20pmImaGroupCurrentEntry OBJECT-TYPE -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmImaGroupCurrentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " An entry describing the current PMo data for ImaGroups. " INDEX { xldv20IfIndex, xldv20pmImaGroupCurrentIntervalType } ::= { xldv20pmImaGroupCurrentTable 1 } Xldv20pmImaGroupCurrentEntry ::= SEQUENCE { xldv20pmImaGroupCurrentIntervalType Xldv20pmIntervalType, xldv20pmImaGroupCurrentAdminState Xldv20AdminState, xldv20pmImaGroupCurrentSuspectFlag Xldv20pmSuspectType, xldv20pmImaGroupCurrentHistEntrySize INTEGER, xldv20pmImaGroupCurrentNrHistEntriesAvailable INTEGER, xldv20pmImaGroupCurrentElapsedTime INTEGER, xldv20pmImaGroupCurrentThresholdLimitIndex INTEGER, xldv20pmImaGroupCurrentUnavailSecs Gauge, xldv20pmImaGroupCurrentNeNumFailures Gauge } xldv20pmImaGroupCurrentIntervalType OBJECT-TYPE -- info-VALUE: min15(1), day(2) -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmIntervalType ACCESS read-only STATUS mandatory DESCRIPTION " This type attribute is used to select between the 15 min or the day accumulation types. " ::= { xldv20pmImaGroupCurrentEntry 1 } xldv20pmImaGroupCurrentAdminState OBJECT-TYPE -- info-VALUE: unlocked(1), locked(2) -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20AdminState ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute is used to activate (unlock) and deactivate (lock) the functions (incl. collection) performed by this managed entity. Note: the 15min collection object must be activated, before day collection can operate. " ::= { xldv20pmImaGroupCurrentEntry 2 } xldv20pmImaGroupCurrentSuspectFlag OBJECT-TYPE -- info-VALUE: reliable(1), suspect(2) -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmSuspectType ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute will be set to indicate that troubles arose during an interval and that the counter values are suspect and incomplete. " ::= { xldv20pmImaGroupCurrentEntry 3 } xldv20pmImaGroupCurrentHistEntrySize OBJECT-TYPE -- info-VALUE: 1..96 (default 1) -- info-VALUE: day counter : 1. min15 counter: 1..96 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (1..96) ACCESS read-only STATUS mandatory DESCRIPTION " This is the configured size of history. " ::= { xldv20pmImaGroupCurrentEntry 4 } xldv20pmImaGroupCurrentNrHistEntriesAvailable OBJECT-TYPE -- info-VALUE: day counter : 0,1.min15 counter: 0..96 (default 0) -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..96) ACCESS read-only STATUS mandatory DESCRIPTION " This is the number of history entries which are available in the history table. " ::= { xldv20pmImaGroupCurrentEntry 5 } xldv20pmImaGroupCurrentElapsedTime OBJECT-TYPE -- info-VALUE: 0..900 (sec) for min15, -- info-VALUE: 0..1440 (min) for day -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER(0..1440) ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents the difference between the current time and the start of the present summary interval. Units are seconds when 15 minute interval is selected or minutes for day interval. (Note: accurate to the sample time interval). " ::= { xldv20pmImaGroupCurrentEntry 6 } xldv20pmImaGroupCurrentThresholdLimitIndex OBJECT-TYPE -- info-VALUE: 1..30 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (1..30) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute provides an index to the ThresholdLimitTable managed entity that contains the threshold limits for the performance parameters reported by this managed entity. When the value of this attribute is set to 1, default threshold limits shall be used . " ::= { xldv20pmImaGroupCurrentEntry 7 } xldv20pmImaGroupCurrentUnavailSecs OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION " The counts of second intervals where the IMA group traffic state machine is down in the current for a 15 min /day interval. " ::= { xldv20pmImaGroupCurrentEntry 8 } xldv20pmImaGroupCurrentNeNumFailures OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION " The number of times a near-end group failure (config-Aborted, unsufficient-Links) has been reported for a 15 min /day interval. " ::= { xldv20pmImaGroupCurrentEntry 9 } -- -------------------------------------------------------------- -- PMo I M A Group H i s t o r y subtree -- -------------------------------------------------------------- -- This section combines the -- the IMA Group Interval Statistics subtree and -- the IMA Group Total Statistics subtree. -- It consists of a single table: -- the IMA Group History Table. -- -- Selection the xldv20pmImaGroupHistoryIntervalType min15 : -- the entries contain various statistics -- collected by each IMA Group over the previous 24 hours of operation. -- -- Selection the xldv20pmImaGroupHistoryIntervalType day : -- The entries contain the cumulative sum -- of the various statistics collected by each IMA Group for the 24 hour -- period preceding the current interval. -- xldv20pmImaGroupHistoryTable OBJECT-TYPE -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX SEQUENCE OF Xldv20pmImaGroupHistoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " This table contains the entries for the 15 min /one day-history data collection results for PMo objects of IMA Group interfaces. " --DEFAULT test-function-async fsnPmIghEntryTest --DEFAULT next-function-async fsnPmIghEntryNext --DEFAULT set-function-async fsnPmIghEntrySet --DEFAULT get-function-async fsnPmIghEntryGet ::= { xldv20pmPerformanceMonitoring 15 } xldv20pmImaGroupHistoryEntry OBJECT-TYPE -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmImaGroupHistoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " An entry describing the History Data Table for PMo IMA groups. " INDEX { xldv20IfIndex, xldv20pmImaGroupHistoryIntervalType, xldv20pmImaGroupHistoryHistEntryNr } ::= { xldv20pmImaGroupHistoryTable 1 } Xldv20pmImaGroupHistoryEntry ::= SEQUENCE { xldv20pmImaGroupHistoryIntervalType Xldv20pmIntervalType, xldv20pmImaGroupHistoryHistEntryNr INTEGER, xldv20pmImaGroupHistorySuspectFlag Xldv20pmSuspectType, xldv20pmImaGroupHistoryPeriodEndTime INTEGER, xldv20pmImaGroupHistoryUnavailSecs Gauge, xldv20pmImaGroupHistoryNeNumFailures Gauge } xldv20pmImaGroupHistoryIntervalType OBJECT-TYPE -- info-VALUE: min15(1), day(2) -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmIntervalType ACCESS read-only STATUS mandatory DESCRIPTION " This type attribute is used to select between the 15 min or the day accumulation types. " ::= { xldv20pmImaGroupHistoryEntry 1 } xldv20pmImaGroupHistoryHistEntryNr OBJECT-TYPE -- info-VALUE: 1..96 -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (1..96) ACCESS read-only STATUS mandatory DESCRIPTION " This attribute is used as index to address a history entry. Entry 1 is the most recent, entry 96 is 24 hours ago. The range of values is between 1 and xldv20pmImaGroupCurrentHistEntrySize . " ::= { xldv20pmImaGroupHistoryEntry 2 } xldv20pmImaGroupHistorySuspectFlag OBJECT-TYPE -- info-VALUE: reliable(1), suspect(2) -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmSuspectType ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute will be set to indicate that troubles arose during an interval and that the counter values are suspect and incomplete. " ::= { xldv20pmImaGroupHistoryEntry 3 } xldv20pmImaGroupHistoryPeriodEndTime OBJECT-TYPE -- info-VALUE: 0..2147483647 -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER(0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION " Date/time at the end of the selected interval. " ::= { xldv20pmImaGroupHistoryEntry 4 } xldv20pmImaGroupHistoryUnavailSecs OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION " The counts of second intervals where the IMA group traffic state machine is down in the current 15 min /day interval. " ::= { xldv20pmImaGroupHistoryEntry 5 } xldv20pmImaGroupHistoryNeNumFailures OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION " The number of times a near-end group failure (config-Aborted, unsufficient-Links) has been reported for a previous 15 min interval or the previous day. " ::= { xldv20pmImaGroupHistoryEntry 6 } -- -------------------------------------------------------------- -- PMo I M A Link C u r r e n t Table -- -------------------------------------------------------------- xldv20pmImaLinkCurrentTable OBJECT-TYPE -- info-IMPL: V2.0-> SYNTAX SEQUENCE OF Xldv20pmImaLinkCurrentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " This table contains the entries for the the PMo objects for the current data of Pmo monitoring objects for IMA groups . It includes attributes for performance parameters, collection interval is 15 minutes and one day . " --DEFAULT test-function-async fsnPmIlcEntryTest --DEFAULT next-function-async fsnPmIlcEntryNext --DEFAULT set-function-async fsnPmIlcEntrySet --DEFAULT get-function-async fsnPmIlcEntryGet ::= { xldv20pmPerformanceMonitoring 16 } xldv20pmImaLinkCurrentEntry OBJECT-TYPE -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmImaLinkCurrentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " An entry describing the current PMo data for ImaLinks. " INDEX { xldv20IfIndex, xldv20pmImaLinkCurrentIntervalType } ::= { xldv20pmImaLinkCurrentTable 1 } Xldv20pmImaLinkCurrentEntry ::= SEQUENCE { xldv20pmImaLinkCurrentIntervalType Xldv20pmIntervalType, xldv20pmImaLinkCurrentAdminState Xldv20AdminState, xldv20pmImaLinkCurrentSuspectFlag Xldv20pmSuspectType, xldv20pmImaLinkCurrentHistEntrySize INTEGER, xldv20pmImaLinkCurrentNrHistEntriesAvailable INTEGER, xldv20pmImaLinkCurrentElapsedTime INTEGER, xldv20pmImaLinkCurrentThresholdLimitIndex INTEGER, xldv20pmImaLinkCurrentImaViolations Gauge, xldv20pmImaLinkCurrentOifAnomalies Gauge, xldv20pmImaLinkCurrentNeSevErroredSecs Gauge, xldv20pmImaLinkCurrentFeSevErroredSecs Gauge, xldv20pmImaLinkCurrentNeUnavailSecs Gauge, xldv20pmImaLinkCurrentFeUnavailSecs Gauge, xldv20pmImaLinkCurrentNeTxUnusableSecs Gauge, xldv20pmImaLinkCurrentNeRxUnusableSecs Gauge, xldv20pmImaLinkCurrentFeTxUnusableSecs Gauge, xldv20pmImaLinkCurrentFeRxUnusableSecs Gauge, xldv20pmImaLinkCurrentNeTxNumFailures Gauge, xldv20pmImaLinkCurrentNeRxNumFailures Gauge } xldv20pmImaLinkCurrentIntervalType OBJECT-TYPE -- info-VALUE: min15(1), day(2) -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmIntervalType ACCESS read-only STATUS mandatory DESCRIPTION " This type attribute is used to select between the 15 min or the day accumulation types. " ::= { xldv20pmImaLinkCurrentEntry 1 } xldv20pmImaLinkCurrentAdminState OBJECT-TYPE -- info-VALUE: unlocked(1), locked(2) -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20AdminState ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute is used to activate (unlock) and deactivate (lock) the functions (incl. collection) performed by this managed entity. Note: the 15min collection object must be activated, before day collection can operate. " ::= { xldv20pmImaLinkCurrentEntry 2 } xldv20pmImaLinkCurrentSuspectFlag OBJECT-TYPE -- info-VALUE: reliable(1), suspect(2) -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmSuspectType ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute will be set to indicate that troubles arose during an interval and that the counter values are suspect and incomplete. " ::= { xldv20pmImaLinkCurrentEntry 3 } xldv20pmImaLinkCurrentHistEntrySize OBJECT-TYPE -- info-VALUE: 1..96 (default 1) -- info-VALUE: day counter : 1. min15 counter: 1..96 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (1..96) ACCESS read-only STATUS mandatory DESCRIPTION " This is the configured size of history. " ::= { xldv20pmImaLinkCurrentEntry 4 } xldv20pmImaLinkCurrentNrHistEntriesAvailable OBJECT-TYPE -- info-VALUE: day counter : 0,1.min15 counter: 0..96 (default 0) -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..96) ACCESS read-only STATUS mandatory DESCRIPTION " This is the number of history entries which are available in the history table. " ::= { xldv20pmImaLinkCurrentEntry 5 } xldv20pmImaLinkCurrentElapsedTime OBJECT-TYPE -- info-VALUE: 0..900 (sec) for min15, -- info-VALUE: 0..1440 (min) for day -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER(0..1440) ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents the difference between the current time and the start of the present summary interval. Units are seconds when 15 minute interval is selected or minutes for day interval. (Note: accurate to the sample time interval). " ::= { xldv20pmImaLinkCurrentEntry 6 } xldv20pmImaLinkCurrentThresholdLimitIndex OBJECT-TYPE -- info-VALUE: 1..30 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (1..30) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute provides an index to the ThresholdLimitTable managed entity that contains the threshold limits for the performance parameters reported by this managed entity. When the value of this attribute is set to 1, default threshold limits shall be used . " ::= { xldv20pmImaLinkCurrentEntry 7 } xldv20pmImaLinkCurrentImaViolations OBJECT-TYPE -- info-VALUE: -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "ICP violations: count of errored, invalid or missing ICP cells, except during SES-IMA or UAS-IMA conditions, in the current 15 minute interval. ATM Forum IMA v1.1, (R-125) and (O-26) in Section 12.2.2.2 on page 77. " ::= { xldv20pmImaLinkCurrentEntry 8 } xldv20pmImaLinkCurrentOifAnomalies OBJECT-TYPE -- info-VALUE: -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of OIF anomalies, except during SES-IMA or UAS-IMA conditions, at the near-end in the current 15 minute interval. This is an optional attribute. ATM Forum IMA v1.1, (O-20) and (O-26) in Section 12.2.2.2 on page 77" ::= { xldv20pmImaLinkCurrentEntry 9 } xldv20pmImaLinkCurrentNeSevErroredSecs OBJECT-TYPE -- info-VALUE: -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Count of one second intervals containing >= 30% of the ICP cells counted as IV-IMAs, or one or more link defects (e.g., LOS, OOF/LOF, AIS, or LCD), LIF defects, or LODS defects, except during UAS-IMA condition, in the current 15 minute interval. ATM Forum IMA v1.1, (R-126) and (O-26) in Section 12.2.2.2 on page 77" ::= { xldv20pmImaLinkCurrentEntry 10 } xldv20pmImaLinkCurrentFeSevErroredSecs OBJECT-TYPE -- info-VALUE: -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Count of unavailable seconds at near-end in the current 15 minute interval: unavailability begins at the onset of 10 contiguous SES-IMA and ends at the onset of 10 contiguous seconds with no SES-IMA. ATM Forum IMA v1.1, (R-128) and (O-26) in Section 12.2.2.2 on page 77" ::= { xldv20pmImaLinkCurrentEntry 11 } xldv20pmImaLinkCurrentNeUnavailSecs OBJECT-TYPE -- info-VALUE: -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Count of unavailable seconds at near-end in the current 15 minute interval: unavailability begins at the onset of 10 contiguous SES-IMA-FE and ends at the onset of 10 contiguous seconds with no SES-IMA-FE. ATM Forum IMA v1.1, (R-129) and (O-26) in Section 12.2.2.2 on page 77 . " ::= { xldv20pmImaLinkCurrentEntry 12 } xldv20pmImaLinkCurrentFeUnavailSecs OBJECT-TYPE -- info-VALUE: -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Count of unavailable seconds at far-end in the current 15 minute interval: unavailability begins at the onset of 10 contiguous SES-IMA-FE and ends at the onset of 10 contiguous seconds with no SES-IMA-FE. ATM Forum IMA v1.1, (R-129) and (O-26) in Section 12.2.2.2 on page 77 . " ::= { xldv20pmImaLinkCurrentEntry 13 } xldv20pmImaLinkCurrentNeTxUnusableSecs OBJECT-TYPE -- info-VALUE: -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Tx Unusable seconds: count of Unusable seconds at the near-end Tx LSM in the current 15 minute interval. ATM Forum IMA v1.1, (R-130) and (O-26) in Section 12.2.2.2 on page 77. " ::= { xldv20pmImaLinkCurrentEntry 14 } xldv20pmImaLinkCurrentNeRxUnusableSecs OBJECT-TYPE -- info-VALUE: -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Rx Unusable seconds: count of Unusable seconds at the near-end Rx LSM in the current 15 minute interval. ATM Forum IMA v1.1, (R-131) and (O-26) in Section 12.2.2.2 on page 77. " ::= { xldv20pmImaLinkCurrentEntry 15 } xldv20pmImaLinkCurrentFeTxUnusableSecs OBJECT-TYPE -- info-VALUE: -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Tx Unusable seconds: count of Unusable seconds at the far-end Tx LSM in the current 15 minute interval. ATM Forum IMA v1.1, (R-132) and (O-26) in Section 12.2.2.2 on page 77. " ::= { xldv20pmImaLinkCurrentEntry 16 } xldv20pmImaLinkCurrentFeRxUnusableSecs OBJECT-TYPE -- info-VALUE: -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Rx Unusable seconds: count of Unusable seconds at the far-end Rx LSM in the current 15 minute interval. ATM Forum IMA v1.1, (R-133) and (O-26) in Section 12.2.2.2 on page 77. " ::= { xldv20pmImaLinkCurrentEntry 17 } xldv20pmImaLinkCurrentNeTxNumFailures OBJECT-TYPE -- info-VALUE: -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of times a near-end transmit failure alarm condition has been entered on this link (i.e., some form of implementation specific transmit fault) in the current 15 minute interval. ATM Forum IMA v1.1, (R-134) and (O-26) in Section 12.2.2.2 on page 77" ::= { xldv20pmImaLinkCurrentEntry 18 } xldv20pmImaLinkCurrentNeRxNumFailures OBJECT-TYPE -- info-VALUE: -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of times a near-end receive failure alarm condition has been entered on this link (i.e., LIF, LODS, RFI-IMA, Mis-Connected, or some form of implementation specific receive fault) in the current 15 minute interval. ATM Forum IMA v1.1, (R-135) and (O-26) in Section 12.2.2.2 on page 77" ::= { xldv20pmImaLinkCurrentEntry 19 } -- -------------------------------------------------------------- -- PMo I M A Link H i s t o r y subtree -- -------------------------------------------------------------- -- This section combines the -- the IMA Link Interval Statistics subtree and -- the IMA Link Total Statistics subtree. -- It consists of a single table: -- the IMA Link History Table. -- -- Selection the xldv20pmIntervalType min15 : -- the entries contain various statistics -- collected by each IMA link over the previous 24 hours of operation. -- -- Selection the xldv20pmIntervalType day : -- The entries contain the cumulative sum -- of the various statistics collected by each IMA link for the 24 hour -- period preceding the current interval. -- xldv20pmImaLinkHistoryTable OBJECT-TYPE -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX SEQUENCE OF Xldv20pmImaLinkHistoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " This table contains the entries for the 15 min /one day-history data collection results for PMo objects of IMA Link interfaces. " --DEFAULT next-function-async fsnPmIlhEntryNext --DEFAULT get-function-async fsnPmIlhEntryGet ::= { xldv20pmPerformanceMonitoring 17 } xldv20pmImaLinkHistoryEntry OBJECT-TYPE -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmImaLinkHistoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " An entry describing the History Data Table for PMo IMA groups. " INDEX { xldv20IfIndex, xldv20pmImaLinkHistoryIntervalType, xldv20pmImaLinkHistoryHistEntryNr } ::= { xldv20pmImaLinkHistoryTable 1 } Xldv20pmImaLinkHistoryEntry ::= SEQUENCE { xldv20pmImaLinkHistoryIntervalType Xldv20pmIntervalType, xldv20pmImaLinkHistoryHistEntryNr INTEGER, xldv20pmImaLinkHistorySuspectFlag Xldv20pmSuspectType, xldv20pmImaLinkHistoryPeriodEndTime INTEGER, xldv20pmImaLinkHistoryImaViolations Gauge, xldv20pmImaLinkHistoryOifAnomalies Gauge, xldv20pmImaLinkHistoryNeSevErroredSecs Gauge, xldv20pmImaLinkHistoryFeSevErroredSecs Gauge, xldv20pmImaLinkHistoryNeUnavailSecs Gauge, xldv20pmImaLinkHistoryFeUnavailSecs Gauge, xldv20pmImaLinkHistoryNeTxUnusableSecs Gauge, xldv20pmImaLinkHistoryNeRxUnusableSecs Gauge, xldv20pmImaLinkHistoryFeTxUnusableSecs Gauge, xldv20pmImaLinkHistoryFeRxUnusableSecs Gauge, xldv20pmImaLinkHistoryNeTxNumFailures Gauge, xldv20pmImaLinkHistoryNeRxNumFailures Gauge } xldv20pmImaLinkHistoryIntervalType OBJECT-TYPE -- info-VALUE: min15(1), day(2) -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmIntervalType ACCESS read-only STATUS mandatory DESCRIPTION " This type attribute is used to select between the 15 min or the day accumulation types. " ::= { xldv20pmImaLinkHistoryEntry 1 } xldv20pmImaLinkHistoryHistEntryNr OBJECT-TYPE -- info-VALUE: 1..96 -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (1..96) ACCESS read-only STATUS mandatory DESCRIPTION " This attribute is used as index to address a history entry. Entry 1 is the most recent, entry 96 is 24 hours ago. The range of values is between 1 and xldv20pmImaLinkCurrentHistEntrySize . " ::= { xldv20pmImaLinkHistoryEntry 2 } xldv20pmImaLinkHistorySuspectFlag OBJECT-TYPE -- info-VALUE: reliable(1), suspect(2) -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmSuspectType ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute will be set to indicate that troubles arose during an interval and that the counter values are suspect and incomplete. " ::= { xldv20pmImaLinkHistoryEntry 3 } xldv20pmImaLinkHistoryPeriodEndTime OBJECT-TYPE -- info-VALUE: 0..2147483647 -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER(0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION " Date/time at the end of the selected interval. " ::= { xldv20pmImaLinkHistoryEntry 4 } xldv20pmImaLinkHistoryImaViolations OBJECT-TYPE -- info-VALUE: -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "ICP violations: count of errored, invalid or missing ICP cells, except during SES-IMA or UAS-IMA conditions, in one of the previous 96, individual 15 minute, intervals or the previous day. ATM Forum IMA v1.1, (R-125) and (O-26) in Section 12.2.2.2 on page 77. " ::= { xldv20pmImaLinkHistoryEntry 5 } xldv20pmImaLinkHistoryOifAnomalies OBJECT-TYPE -- info-VALUE: -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of OIF anomalies, except during SES-IMA or UAS-IMA conditions, at the near-end in one of the previous 96, individual 15 minute, intervals or the previous day. This is an optional attribute. ATM Forum IMA v1.1, (O-20) and (O-26) in Section 12.2.2.2 on page 77" ::= { xldv20pmImaLinkHistoryEntry 6 } xldv20pmImaLinkHistoryNeSevErroredSecs OBJECT-TYPE -- info-VALUE: -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Count of one second intervals containing >= 30% of the ICP cells counted as IV-IMAs, or one or more link defects (e.g., LOS, OOF/LOF, AIS, or LCD), LIF defects, or LODS defects, except during UAS-IMA condition, in one of the previous 96, individual 15 minute, intervals or the previous day. ATM Forum IMA v1.1, (R-126) and (O-26) in Section 12.2.2.2 on page 77" ::= { xldv20pmImaLinkHistoryEntry 7 } xldv20pmImaLinkHistoryFeSevErroredSecs OBJECT-TYPE -- info-VALUE: -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Count of unavailable seconds at near-end in one of the previous 96, individual 15 minute, intervals or the previous day. Unavailability begins at the onset of 10 contiguous SES-IMA and ends at the onset of 10 contiguous seconds with no SES-IMA. ATM Forum IMA v1.1, (R-127) and (O-26) in Section 12.2.2.2 on page 77" ::= { xldv20pmImaLinkHistoryEntry 8 } xldv20pmImaLinkHistoryNeUnavailSecs OBJECT-TYPE -- info-VALUE: -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Count of unavailable seconds at near-end in one of the previous 96, individual 15 minute, intervals or the previous day. Unavailability begins at the onset of 10 contiguous SES-IMA and ends at the onset of 10 contiguous seconds with no SES-IMA. ATM Forum IMA v1.1, (R-128) and (O-26) in Section 12.2.2.2 on page 77 . " ::= { xldv20pmImaLinkHistoryEntry 9 } xldv20pmImaLinkHistoryFeUnavailSecs OBJECT-TYPE -- info-VALUE: -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Count of unavailable seconds at far-end in one of the previous 96, individual 15 minute, intervals or the previous day. Unavailability begins at the onset of 10 contiguous SES-IMA-FE and ends at the onset of 10 contiguous seconds with no SES-IMA-FE. ATM Forum IMA v1.1, (R-129) and (O-26) in Section 12.2.2.2 on page 77 . " ::= { xldv20pmImaLinkHistoryEntry 10 } xldv20pmImaLinkHistoryNeTxUnusableSecs OBJECT-TYPE -- info-VALUE: -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Tx Unusable seconds: count of Unusable seconds at the near-end Tx LSM in one of the previous 96, individual 15 minute, intervals or the previous day. ATM Forum IMA v1.1, (R-130) and (O-26) in Section 12.2.2.2 on page 77. " ::= { xldv20pmImaLinkHistoryEntry 11 } xldv20pmImaLinkHistoryNeRxUnusableSecs OBJECT-TYPE -- info-VALUE: -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Rx Unusable seconds: count of Unusable seconds at the near-end Rx LSM in one of the previous 96, individual 15 minute, intervals or the previous day. ATM Forum IMA v1.1, (R-131) and (O-26) in Section 12.2.2.2 on page 77. " ::= { xldv20pmImaLinkHistoryEntry 12 } xldv20pmImaLinkHistoryFeTxUnusableSecs OBJECT-TYPE -- info-VALUE: -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Tx Unusable seconds: count of Unusable seconds at the far-end Tx LSM in one of the previous 96, individual 15 minute, intervals or the previous day. ATM Forum IMA v1.1, (R-132) and (O-26) in Section 12.2.2.2 on page 77. " ::= { xldv20pmImaLinkHistoryEntry 13 } xldv20pmImaLinkHistoryFeRxUnusableSecs OBJECT-TYPE -- info-VALUE: -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Rx Unusable seconds: count of Unusable seconds at the far-end Rx LSM in one of the previous 96, individual 15 minute, intervals or the previous day. ATM Forum IMA v1.1, (R-133) and (O-26) in Section 12.2.2.2 on page 77. " ::= { xldv20pmImaLinkHistoryEntry 14 } xldv20pmImaLinkHistoryNeTxNumFailures OBJECT-TYPE -- info-VALUE: -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of times a near-end transmit failure alarm condition has been entered on this link (i.e., some form of implementation specific transmit fault) in one of the previous 96, individual 15 minute, intervals or the previous day. ATM Forum IMA v1.1, (R-134) and (O-26) in Section 12.2.2.2 on page 77" ::= { xldv20pmImaLinkHistoryEntry 15 } xldv20pmImaLinkHistoryNeRxNumFailures OBJECT-TYPE -- info-VALUE: -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of times a near-end receive failure alarm condition has been entered on this link (i.e., LIF, LODS, RFI-IMA, Mis-Connected, or some form of implementation specific receive fault) in one of the previous 96, individual 15 minute, intervals or the previous day. ATM Forum IMA v1.1, (R-135) and (O-26) in Section 12.2.2.2 on page 77" ::= { xldv20pmImaLinkHistoryEntry 16 } -- ============================================================== -- P r o t o c o l M o n i t o r i n g (PrM) -- g r o u p -- ============================================================== -- -------------------------------------------------------------- -- PrM T C - A d a p t o r C u r r e n t D a t a Table -- -------------------------------------------------------------- xldv20pmTcaPrMCurrentTable OBJECT-TYPE -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX SEQUENCE OF Xldv20pmTcaPrMCurrentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " This table contains the entries for the PrM object at the following tca layer locations: - STM1 interface (in downstream direction) - STS3-c interface (in downstream direction) - E3 interface (in downstream direction) - DS3 interface (in downstream direction) - SU_AD16 interfaces (in upstream stream direction). PrM also possible at IMA groups. It includes attributes for performance parameters, collection interval is 15 min /one day . " --DEFAULT test-function-async fsnTcEntryTest --DEFAULT next-function-async fsnTcEntryNext --DEFAULT set-function-async fsnTcEntrySet --DEFAULT get-function-async fsnTcEntryGet ::= { xldv20pmProtocolMonitoring 1 } xldv20pmTcaPrMCurrentEntry OBJECT-TYPE -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmTcaPrMCurrentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " An entry describing the TC-Adaptor Current Data Table . " INDEX { xldv20IfIndex, xldv20pmTcIntervalType } ::= { xldv20pmTcaPrMCurrentTable 1 } Xldv20pmTcaPrMCurrentEntry ::= SEQUENCE { xldv20pmTcIntervalType Xldv20pmIntervalType, xldv20pmTcAdminState Xldv20AdminState, xldv20pmTcSuspectFlag Xldv20pmSuspectType, xldv20pmTcHistEntrySize INTEGER, xldv20pmTcNrHistEntriesAvailable INTEGER, xldv20pmTcElapsedTime INTEGER, xldv20pmTcThresholdLimitIndex INTEGER, xldv20pmTcDiscardedCells Counter } xldv20pmTcIntervalType OBJECT-TYPE -- info-VALUE: min15(1), day(2) -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmIntervalType ACCESS read-only STATUS mandatory DESCRIPTION " This nac type attribute is used to select between the 15 min or the day accumulation types. " ::= { xldv20pmTcaPrMCurrentEntry 1 } xldv20pmTcAdminState OBJECT-TYPE -- info-VALUE: unlocked(1), locked(2) -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20AdminState ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute is used to activate (unlock) and deactivate (lock) the functions (incl. collection) performed by this managed entity. Note: the 15min collection object must be activated, before day collection can operate. " ::= { xldv20pmTcaPrMCurrentEntry 2 } xldv20pmTcSuspectFlag OBJECT-TYPE -- info-VALUE: reliable(1), suspect(2) -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmSuspectType ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute will be set to indicate that troubles arose during an interval and that the counter values are suspect and incomplete. " ::= { xldv20pmTcaPrMCurrentEntry 3 } xldv20pmTcHistEntrySize OBJECT-TYPE -- info-VALUE: 1..96 -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (1..96) ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute indicates the number of 15min history entries configured for the particular interface. The default value is 1 and means that at least one history entry is provided. " ::= { xldv20pmTcaPrMCurrentEntry 4 } xldv20pmTcNrHistEntriesAvailable OBJECT-TYPE -- info-VALUE: 0..96 -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..96) ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute indicates how many HistEntries are already available. The range of values is between 0 and xldv20pmTcHistEntrySize, thereby 0 means that this entry is not valid . " ::= { xldv20pmTcaPrMCurrentEntry 5 } xldv20pmTcElapsedTime OBJECT-TYPE -- info-VALUE: 0..900 (sec) for min15, -- info-VALUE: 0..1440 (min) for day -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..1440) ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents the difference between the current time and the start of the present summary interval. Units are seconds when 15 minute interval is selected or minutes for day interval. (Note: accurate to the sample time interval). " ::= { xldv20pmTcaPrMCurrentEntry 6 } xldv20pmTcThresholdLimitIndex OBJECT-TYPE -- info-VALUE: 1..30 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (1..30) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute provides an index to the ThresholdLimitTable managed entity that contains the threshold limits for the performance parameters reported by this managed entity. When the value of this attribute is set to 1, default threshold limits shall be used. These default values are not part of the threshold limit table but are hard coded in the application SW of PM. " ::= { xldv20pmTcaPrMCurrentEntry 7 } xldv20pmTcDiscardedCells OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a counter of the number of ATM cells discarded at this interface, due to a HEC violation, since the start of this interval . " ::= { xldv20pmTcaPrMCurrentEntry 8 } -- -------------------------------------------------------------- -- PrM T C - A d a p t o r H i s t o r y D a t a Table -- -------------------------------------------------------------- xldv20pmTcaPrMHistoryTable OBJECT-TYPE -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX SEQUENCE OF Xldv20pmTcaPrMHistoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " This table contains the entries for the PrM history object at the different tca layer locations. It contains results that are overtaken from the TcaPrMCurrentTable PM-object at the end of a 15 min /day interval . " --DEFAULT next-function-async fsnThEntryNext --DEFAULT get-function-async fsnThEntryGet ::= { xldv20pmProtocolMonitoring 2 } xldv20pmTcaPrMHistoryEntry OBJECT-TYPE -- info-ROU: GET SET [db,pm] -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmTcaPrMHistoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " An entry describing the TC-Adaptor History Data Table . " INDEX { xldv20IfIndex, xldv20pmThIntervalType, xldv20pmThHistEntryNr } ::= { xldv20pmTcaPrMHistoryTable 1 } Xldv20pmTcaPrMHistoryEntry ::= SEQUENCE { xldv20pmThIntervalType Xldv20pmIntervalType, xldv20pmThHistEntryNr INTEGER, xldv20pmThSuspectFlag Xldv20pmSuspectType, xldv20pmThPeriodEndTime INTEGER, xldv20pmThDiscardedCells Counter } xldv20pmThIntervalType OBJECT-TYPE -- info-VALUE: min15(1), day(2) -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmIntervalType ACCESS read-only STATUS mandatory DESCRIPTION " This type attribute is used to select between the 15 min or the day accumulation types. " ::= { xldv20pmTcaPrMHistoryEntry 1 } xldv20pmThHistEntryNr OBJECT-TYPE -- info-VALUE: 1..96 -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (1..96) ACCESS read-only STATUS mandatory DESCRIPTION " This attribute is used as index to address a history entry. Entry 1 is the most recent, entry 96 is 24 hours ago. The range of values is between 1 and xldv20pmTcHistEntrySize. " ::= { xldv20pmTcaPrMHistoryEntry 2 } xldv20pmThSuspectFlag OBJECT-TYPE -- info-VALUE: reliable(1), suspect(2) -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmSuspectType ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute will be set to indicate that troubles arose during an interval and that the counter values are suspect and incomplete. " ::= { xldv20pmTcaPrMHistoryEntry 3 } xldv20pmThPeriodEndTime OBJECT-TYPE -- info-VALUE: 0..2147483647 -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER(0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute is a record of date/time at the end of an interval . " ::= { xldv20pmTcaPrMHistoryEntry 4 } xldv20pmThDiscardedCells OBJECT-TYPE -- info-VALUE: - -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute represents a set of history counter of the number of ATM cells discarded at this interface, due to a HEC violation, since the start of this interval . " ::= { xldv20pmTcaPrMHistoryEntry 5 } -- ============================================================== -- P e r f o r m a n c e M a n a g e m e n t -- T h r e s h o l d i n g g r o u p -- ============================================================== -- -------------------------------------------------------------- -- Thresholding Table for PM on Physical layer -- (all Interfaces) -- -------------------------------------------------------------- xldv20pmThresholdLimitTable OBJECT-TYPE -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX SEQUENCE OF Xldv20pmThresholdLimitEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " The threshold limit table for all interface. This table associates threshold limit index/PM counter pairs with threshold limit values for a 15 minutes interval. Entries with same threshold limit index belong to the same threshold limit profile. Each of the following TC-adaptor types are available and can be configured: adc, s1n, s3n, d3n, e3n. A crossing of a threshold limit leads to a threshold crossing alert. " --DEFAULT test-function-async fsnPmThlEntryTest --DEFAULT next-function-async fsnPmThlEntryNext --DEFAULT set-function-async fsnPmThlEntrySet --DEFAULT get-function-async fsnPmThlEntryGet ::= { xldv20pmThresholding 1 } xldv20pmThresholdLimitEntry OBJECT-TYPE -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmThresholdLimitEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " An entry describing the threshold limit information . " INDEX { xldv20pmThlThresholdLimitIndex } ::= { xldv20pmThresholdLimitTable 1 } Xldv20pmThresholdLimitEntry ::= SEQUENCE { xldv20pmThlThresholdLimitIndex INTEGER, xldv20pmThlNeBackgroundBlockErrors INTEGER, -- s1f, adc, e3n xldv20pmThlNeCodeViolations INTEGER, -- s3n xldv20pmThlNeCodeViolationsCP INTEGER, -- d3n xldv20pmThlNeCodeViolationsP INTEGER, -- d3n xldv20pmThlNeCodeViolationsPLCP INTEGER, -- d3n xldv20pmThlNeErroredSeconds INTEGER, -- adc, e3n xldv20pmThlNeErroredSecondsCP INTEGER, -- d3n xldv20pmThlNeErroredSecondsPLCP INTEGER, -- d3n xldv20pmThlNeSas INTEGER, -- d3n xldv20pmThlNeSeverelyErroredFrameSeconds INTEGER, -- s3n xldv20pmThlNeSeverelyErroredSeconds INTEGER, -- s1n, s3n, adc, e3n xldv20pmThlNeSeverelyErroredSecondsCP INTEGER, -- d3n xldv20pmThlNeSeverelyErroredSecondsPLCP INTEGER, -- d3n xldv20pmThlNeUnavailableSeconds INTEGER, -- s1n, s3n, d3n, adc, e3n xldv20pmThlNeUnavailableSecondsPLCP INTEGER, -- s3n xldv20pmThlNeAisSeconds INTEGER, -- s1n xldv20pmThlNeOfsSeconds INTEGER, -- s1n xldv20pmThlNeLosSeconds INTEGER, -- s1n xldv20pmThlFeBackgroundBlockErrors INTEGER, -- s1f, adc, e3f xldv20pmThlFeCodeViolations INTEGER, -- s3f xldv20pmThlFeCodeViolationsCP INTEGER, -- d3f xldv20pmThlFeCodeViolationsPLCP INTEGER, -- d3f xldv20pmThlFeErroredSeconds INTEGER, -- s1f, s3f, adr, e3f xldv20pmThlFeErroredSecondsCP INTEGER, -- d3f xldv20pmThlFeErroredSecondsPLCP INTEGER, -- d3f xldv20pmThlFeSas INTEGER, -- d3f xldv20pmThlFeSeverelyErroredSeconds INTEGER, -- s1f, s3f, adr, e3f xldv20pmThlFeSeverelyErroredSecondsCP INTEGER, -- d3f xldv20pmThlFeSeverelyErroredSecondsPLCP INTEGER, -- d3f xldv20pmThlFeUnavailableSeconds INTEGER, -- s1f, s3f, adr, e3f xldv20pmThlFeUnavailableSecondsPLCP INTEGER, -- d3f xldv20pmThlDiscardedCells INTEGER, -- tca xldv20pmThlImaGroupUnavailSecs INTEGER, -- IMA group xldv20pmThlImaGroupNeNumFailures INTEGER, -- IMA group xldv20pmThlImaLinkImaViolations INTEGER, -- IMA link xldv20pmThlImaLinkOifAnomalies INTEGER, -- IMA link xldv20pmThlImaLinkNeSevErroredSecs INTEGER, -- IMA link xldv20pmThlImaLinkFeSevErroredSecs INTEGER, -- IMA link xldv20pmThlImaLinkNeUnavailSecs INTEGER, -- IMA link xldv20pmThlImaLinkFeUnavailSecs INTEGER, -- IMA link xldv20pmThlImaLinkNeTxUnusableSecs INTEGER, -- IMA link xldv20pmThlImaLinkNeRxUnusableSecs INTEGER, -- IMA link xldv20pmThlImaLinkFeTxUnusableSecs INTEGER, -- IMA link xldv20pmThlImaLinkFeRxUnusableSecs INTEGER, -- IMA link xldv20pmThlImaLinkNeTxNumFailures INTEGER, -- IMA link xldv20pmThlImaLinkNeRxNumFailures INTEGER -- IMA link } xldv20pmThlThresholdLimitIndex OBJECT-TYPE -- info-VALUE: 1..30 -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (1..30) ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute selects a profile out of the threshold limit table . " ::= { xldv20pmThresholdLimitEntry 1 } xldv20pmThlNeBackgroundBlockErrors OBJECT-TYPE -- info-VALUE: 0..2147483647 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmThresholdLimitEntry 2 } xldv20pmThlNeCodeViolations OBJECT-TYPE -- info-VALUE: 0..2147483647 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmThresholdLimitEntry 3 } xldv20pmThlNeCodeViolationsCP OBJECT-TYPE -- info-VALUE: 0..2147483647 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmThresholdLimitEntry 4 } xldv20pmThlNeCodeViolationsP OBJECT-TYPE -- info-VALUE: 0..2147483647 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmThresholdLimitEntry 5 } xldv20pmThlNeCodeViolationsPLCP OBJECT-TYPE -- info-VALUE: 0..2147483647 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmThresholdLimitEntry 6 } xldv20pmThlNeErroredSeconds OBJECT-TYPE -- info-VALUE: 0..86400 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..86400) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmThresholdLimitEntry 7 } xldv20pmThlNeErroredSecondsCP OBJECT-TYPE -- info-VALUE: 0..86400 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..86400) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmThresholdLimitEntry 8 } xldv20pmThlNeErroredSecondsPLCP OBJECT-TYPE -- info-VALUE: 0..86400 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..86400) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmThresholdLimitEntry 9 } xldv20pmThlNeSas OBJECT-TYPE -- info-VALUE: 0..86400 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..86400) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmThresholdLimitEntry 10 } xldv20pmThlNeSeverelyErroredFrameSeconds OBJECT-TYPE -- info-VALUE: 0..86400 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..86400) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmThresholdLimitEntry 11 } xldv20pmThlNeSeverelyErroredSeconds OBJECT-TYPE -- info-VALUE: 0..86400 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..86400) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmThresholdLimitEntry 12 } xldv20pmThlNeSeverelyErroredSecondsCP OBJECT-TYPE -- info-VALUE: 0..86400 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..86400) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmThresholdLimitEntry 13 } xldv20pmThlNeSeverelyErroredSecondsPLCP OBJECT-TYPE -- info-VALUE: 0..86400 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..86400) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmThresholdLimitEntry 14 } xldv20pmThlNeUnavailableSeconds OBJECT-TYPE -- info-VALUE: 0..86400 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..86400) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmThresholdLimitEntry 15 } xldv20pmThlNeUnavailableSecondsPLCP OBJECT-TYPE -- info-VALUE: 0..86400 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..86400) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmThresholdLimitEntry 16 } xldv20pmThlNeAisSeconds OBJECT-TYPE -- info-VALUE: 0..86400 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..86400) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmThresholdLimitEntry 17 } xldv20pmThlNeOfsSeconds OBJECT-TYPE -- info-VALUE: 0..86400 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..86400) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmThresholdLimitEntry 18 } xldv20pmThlNeLosSeconds OBJECT-TYPE -- info-VALUE: 0..86400 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..86400) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmThresholdLimitEntry 19 } xldv20pmThlFeBackgroundBlockErrors OBJECT-TYPE -- info-VALUE: 0..2147483647 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmThresholdLimitEntry 20 } xldv20pmThlFeCodeViolations OBJECT-TYPE -- info-VALUE: 0..2147483647 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmThresholdLimitEntry 21 } xldv20pmThlFeCodeViolationsCP OBJECT-TYPE -- info-VALUE: 0..2147483647 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmThresholdLimitEntry 22 } xldv20pmThlFeCodeViolationsPLCP OBJECT-TYPE -- info-VALUE: 0..2147483647 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmThresholdLimitEntry 23 } xldv20pmThlFeErroredSeconds OBJECT-TYPE -- info-VALUE: 0..86400 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..86400) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmThresholdLimitEntry 24 } xldv20pmThlFeErroredSecondsCP OBJECT-TYPE -- info-VALUE: 0..86400 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..86400) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmThresholdLimitEntry 25 } xldv20pmThlFeErroredSecondsPLCP OBJECT-TYPE -- info-VALUE: 0..86400 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..86400) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmThresholdLimitEntry 26 } xldv20pmThlFeSas OBJECT-TYPE -- info-VALUE: 0..86400 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..86400) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmThresholdLimitEntry 27 } xldv20pmThlFeSeverelyErroredSeconds OBJECT-TYPE -- info-VALUE: 0..86400 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..86400) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmThresholdLimitEntry 28 } xldv20pmThlFeSeverelyErroredSecondsCP OBJECT-TYPE -- info-VALUE: 0..86400 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..86400) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmThresholdLimitEntry 29 } xldv20pmThlFeSeverelyErroredSecondsPLCP OBJECT-TYPE -- info-VALUE: 0..86400 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..86400) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmThresholdLimitEntry 30 } xldv20pmThlFeUnavailableSeconds OBJECT-TYPE -- info-VALUE: 0..86400 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..86400) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmThresholdLimitEntry 31 } xldv20pmThlFeUnavailableSecondsPLCP OBJECT-TYPE -- info-VALUE: 0..86400 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..86400) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmThresholdLimitEntry 32 } xldv20pmThlDiscardedCells OBJECT-TYPE -- info-VALUE: 0..2147483647 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmThresholdLimitEntry 33 } xldv20pmThlImaGroupUnavailSecs OBJECT-TYPE -- info-VALUE: 0..2147483647 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmThresholdLimitEntry 34 } xldv20pmThlImaGroupNeNumFailures OBJECT-TYPE -- info-VALUE: 0..2147483647 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmThresholdLimitEntry 35 } xldv20pmThlImaLinkImaViolations OBJECT-TYPE -- info-VALUE: 0..2147483647 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmThresholdLimitEntry 36 } xldv20pmThlImaLinkOifAnomalies OBJECT-TYPE -- info-VALUE: 0..2147483647 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmThresholdLimitEntry 37 } xldv20pmThlImaLinkNeSevErroredSecs OBJECT-TYPE -- info-VALUE: 0..2147483647 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmThresholdLimitEntry 38 } xldv20pmThlImaLinkFeSevErroredSecs OBJECT-TYPE -- info-VALUE: 0..2147483647 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmThresholdLimitEntry 39 } xldv20pmThlImaLinkNeUnavailSecs OBJECT-TYPE -- info-VALUE: 0..2147483647 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmThresholdLimitEntry 40 } xldv20pmThlImaLinkFeUnavailSecs OBJECT-TYPE -- info-VALUE: 0..2147483647 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmThresholdLimitEntry 41 } xldv20pmThlImaLinkNeTxUnusableSecs OBJECT-TYPE -- info-VALUE: 0..2147483647 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmThresholdLimitEntry 42 } xldv20pmThlImaLinkNeRxUnusableSecs OBJECT-TYPE -- info-VALUE: 0..2147483647 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmThresholdLimitEntry 43 } xldv20pmThlImaLinkFeTxUnusableSecs OBJECT-TYPE -- info-VALUE: 0..2147483647 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmThresholdLimitEntry 44 } xldv20pmThlImaLinkFeRxUnusableSecs OBJECT-TYPE -- info-VALUE: 0..2147483647 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmThresholdLimitEntry 45 } xldv20pmThlImaLinkNeTxNumFailures OBJECT-TYPE -- info-VALUE: 0..2147483647 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmThresholdLimitEntry 46 } xldv20pmThlImaLinkNeRxNumFailures OBJECT-TYPE -- info-VALUE: 0..2147483647 -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmThresholdLimitEntry 47 } -- -------------------------------------------------------------- -- Thresholding Table for PM on ATM layer -- -------------------------------------------------------------- xldv20pmAtmThresholdLimitTable OBJECT-TYPE -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX SEQUENCE OF Xldv20pmAtmThresholdLimitEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " The threshold limit table for all interface. This table associates threshold limit index/PM counter pairs with threshold limit values for a 15 minutes interval. Entries with same threshold limit index belong to the same threshold limit profile. A crossing of a threshold limit leads to a threshold crossing alert. " --DEFAULT test-function-async fsnPmAtlEntryTest --DEFAULT next-function-async fsnPmAtlEntryNext --DEFAULT set-function-async fsnPmAtlEntrySet --DEFAULT get-function-async fsnPmAtlEntryGet ::= { xldv20pmThresholding 2 } xldv20pmAtmThresholdLimitEntry OBJECT-TYPE -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX Xldv20pmAtmThresholdLimitEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " An entry describing the threshold limit information . " INDEX { xldv20pmAtlThresholdLimitIndex } ::= { xldv20pmAtmThresholdLimitTable 1 } Xldv20pmAtmThresholdLimitEntry ::= SEQUENCE { xldv20pmAtlThresholdLimitIndex INTEGER, xldv20pmAtlTransmittedUserCells Unsigned32, xldv20pmAtlLostUserCells Unsigned32, xldv20pmAtlMisinsertedUserCells Unsigned32 } xldv20pmAtlThresholdLimitIndex OBJECT-TYPE -- info-VALUE: 1..30 -- info-ROU: GET db -- info-IMPL: V2.0-> -- info-VERCTRL: - SYNTAX INTEGER (1..30) ACCESS read-only STATUS mandatory DESCRIPTION " This read-only attribute selects a profile out of the threshold limit table of PM on ATM layer. " ::= { xldv20pmAtmThresholdLimitEntry 1 } xldv20pmAtlTransmittedUserCells OBJECT-TYPE -- info-VALUE: -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: SYNTAX Unsigned32 ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmAtmThresholdLimitEntry 2 } xldv20pmAtlLostUserCells OBJECT-TYPE -- info-VALUE: -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: SYNTAX Unsigned32 ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmAtmThresholdLimitEntry 3 } xldv20pmAtlMisinsertedUserCells OBJECT-TYPE -- info-VALUE: -- info-ROU: GET db SET pm -- info-IMPL: V2.0-> -- info-VERCTRL: SYNTAX Unsigned32 ACCESS read-write STATUS mandatory DESCRIPTION " This read-write attribute selects the threshold limit value of the counter in the current threshold limit profile. " ::= { xldv20pmAtmThresholdLimitEntry 4 } -- ============================================================== -- P e r f o r m a n c e M a n a g e m e n t -- T r a p g r o u p -- ============================================================== xldv20pmTrapVars OBJECT IDENTIFIER ::= { xldv20pmTraps 1 } -- info-IMPL: V2.0-> -- -------------------------------------------------------------- -- t r a p v a r i a b l e s g r o u p -- -------------------------------------------------------------- xldv20pmTvIfIndex OBJECT-TYPE -- info-VALUE: - -- info-IMPL: V2.0-> SYNTAX Unsigned16 ACCESS not-accessible STATUS mandatory DESCRIPTION " The interface index of the reporting PM object. " ::= { xldv20pmTrapVars 1 } xldv20pmTvPmType OBJECT-TYPE -- info-VALUE: s1F1PMo(1), s1F2PMo(2), -- info-VALUE: s1F3PMo(3), s3F1PMo(4), s3F2PMo(5), -- info-VALUE: s3F3PMo(6), d3F2PMo(7), d3F3PMo(8), -- info-VALUE: e3F3PMo(9), adcF3PMo(10), -- info-VALUE: s1PrM(11), s3PrM(12), e3PrM(13), -- info-VALUE: d3PrM(14), adcPrM(15), -- info-VALUE: e1ImaPrM(16), d1ImaPrM(17), -- info-VALUE: e1ImaPMo(18), d1ImaPMo(19), -- info-VALUE: atmImaPMo(20) -- info-IMPL: V2.0-> SYNTAX Xldv20pmType ACCESS not-accessible STATUS mandatory DESCRIPTION " Specifies the reporting PM object and OAM level. " ::= { xldv20pmTrapVars 2 } xldv20pmTvPmCounter OBJECT-TYPE -- info-VALUE: neBackgroundBlockErrors -- info-VALUE: neCodeViolations -- info-VALUE: neCodeViolationsCP -- info-VALUE: neCodeViolationsP -- info-VALUE: neCodeViolationsPLCP -- info-VALUE: neErroredSeconds -- info-VALUE: neErroredSecondsCP -- info-VALUE: neErroredSecondsPLCP -- info-VALUE: neSeverelyErroredFrameSeconds -- info-VALUE: neSeverelyErroredSeconds -- info-VALUE: neSeverelyErroredSecondsCP -- info-VALUE: neSeverelyErroredSecondsPLCP -- info-VALUE: neUnavailableSeconds -- info-VALUE: neUnavailableSecondsPLCP -- info-VALUE: neAisSeconds -- info-VALUE: neOfsSeconds -- info-VALUE: neLosSeconds -- info-VALUE: feBackgroundBlockErrors -- info-VALUE: feCodeViolations -- info-VALUE: feCodeViolationsCP -- info-VALUE: feCodeViolationsPLCP -- info-VALUE: feErroredSeconds -- info-VALUE: feErroredSecondsCP -- info-VALUE: feErroredSecondsPLCP -- info-VALUE: feSas -- info-VALUE: feSeverelyErroredSeconds -- info-VALUE: feSeverelyErroredSecondsCP -- info-VALUE: feSeverelyErroredSecondsPLCP -- info-VALUE: feUnavailableSeconds -- info-VALUE: feUnavailableSecondsPLCP -- info-VALUE: discardedCells -- info-VALUE: imaGroupUnavailSecs -- info-VALUE: imaGroupNeNumFailures -- info-VALUE: imaLinkImaViolations -- info-VALUE: imaLinkOifAnomalies -- info-VALUE: imaLinkNeSevErroredSecs -- info-VALUE: imaLinkFeSevErroredSecs -- info-VALUE: imaLinkNeUnavailSecs -- info-VALUE: imaLinkFeUnavailSecs -- info-VALUE: imaLinkNeTxUnusableSecs -- info-VALUE: imaLinkNeRxUnusableSecs -- info-VALUE: imaLinkFeTxUnusableSecs -- info-VALUE: imaLinkFeRxUnusableSecs -- info-VALUE: imaLinkNeTxNumFailures -- info-VALUE: imaLinkNeRxNumFailures -- info-IMPL: V2.0-> SYNTAX Xldv20pmCounterName ACCESS not-accessible STATUS mandatory DESCRIPTION " Identifies the PM counter. " ::= { xldv20pmTrapVars 3 } xldv20pmTvCurrentCounterValue OBJECT-TYPE -- info-VALUE: - -- info-IMPL: V2.0-> SYNTAX Counter ACCESS not-accessible STATUS mandatory DESCRIPTION " The actual counter value at detection. " ::= { xldv20pmTrapVars 4 } xldv20pmTvCurrentCounterLimit OBJECT-TYPE -- info-VALUE: - -- info-IMPL: V2.0-> SYNTAX Counter ACCESS not-accessible STATUS mandatory DESCRIPTION " The current value of threshold limit. " ::= { xldv20pmTrapVars 5 } xldv20pmTvAtmPmCounter OBJECT-TYPE -- info-VALUE: - -- info-IMPL: V2.0-> SYNTAX Xldv20pmAtmCounterType ACCESS not-accessible STATUS mandatory DESCRIPTION " Identifies the performance parameter. " ::= { xldv20pmTrapVars 6 } xldv20pmTvAtmObjectIndex OBJECT-TYPE -- info-VALUE: - -- info-IMPL: V2.0-> SYNTAX Unsigned16 ACCESS not-accessible STATUS mandatory DESCRIPTION "Identifies the AtmPm object. " ::= { xldv20pmTrapVars 7 } xldv20pmTvEndpointType OBJECT-TYPE -- info-VALUE: - -- info-IMPL: V2.0-> SYNTAX Xldv20pmEndpointType ACCESS not-accessible STATUS mandatory DESCRIPTION "Identifies the type of endpoint. " ::= { xldv20pmTrapVars 8 } xldv20pmTvIntervalType OBJECT-TYPE -- info-VALUE: - -- info-IMPL: V2.0-> SYNTAX Xldv20pmIntervalType ACCESS not-accessible STATUS mandatory DESCRIPTION "Identifies the type of interval. " ::= { xldv20pmTrapVars 9 } -- -------------------------------------------------------------- -- t r a p t y p e s g r o u p -- f o r P M o n P h y s i c a l L a y e r -- -------------------------------------------------------------- xldv20pmTrapTypes OBJECT IDENTIFIER ::= { xldv20pmTraps 2 } -- info-IMPL: V2.0-> xldv20pmTrThresholdCrossingAlert TRAP-TYPE -- info-TRAPTYPE: event -- info-TRAPID: 200 -- info-IMPL: V2.0-> ENTERPRISE xldv20Traps VARIABLES { xldv20TvTimeAndDate, xldv20pmTvIfIndex, xldv20pmTvPmType, xldv20pmTvPmCounter, xldv20pmTvIntervalType, xldv20pmTvCurrentCounterValue, xldv20pmTvCurrentCounterLimit } DESCRIPTION " Threshold crossing alert for PM on physical layer. " ::= 200 -- -------------------------------------------------------------- -- t r a p t y p e s g r o u p -- f o r P M o n A T M L a y e r -- -------------------------------------------------------------- xldv20pmTrAtmThresholdCrossingAlert TRAP-TYPE -- info-TRAPTYPE: event -- info-TRAPID: 300 -- info-IMPL: V2.0-> ENTERPRISE xldv20Traps VARIABLES { xldv20TvTimeAndDate, xldv20pmTvAtmObjectIndex, xldv20pmTvAtmPmCounter, xldv20pmTvIntervalType, xldv20pmTvCurrentCounterValue, xldv20pmTvCurrentCounterLimit } DESCRIPTION " Threshold crossing alert for PM on ATM layer . " ::= 300 xldv20pmTrAtmObjectCreation TRAP-TYPE -- info-TRAPTYPE: event -- info-TRAPID: 302 -- info-IMPL: V2.0-> ENTERPRISE xldv20Traps VARIABLES { xldv20TvTimeAndDate, xldv20pmTvAtmObjectIndex } DESCRIPTION " An Atm object is created. " ::= 302 xldv20pmTrAtmObjectDeletion TRAP-TYPE -- info-TRAPTYPE: event -- info-TRAPID: 303 -- info-IMPL: V2.0-> ENTERPRISE xldv20Traps VARIABLES { xldv20TvTimeAndDate, xldv20pmTvAtmObjectIndex } DESCRIPTION " An Atm object is deleted. " ::= 303 xldv20pmTrAtmEndpointObjectCreation TRAP-TYPE -- info-TRAPTYPE: event -- info-TRAPID: 304 -- info-IMPL: V2.0-> ENTERPRISE xldv20Traps VARIABLES { xldv20TvTimeAndDate, xldv20pmTvAtmObjectIndex, xldv20pmTvEndpointType } DESCRIPTION " An Atm endpoint object is created. " ::= 304 xldv20pmTrAtmEndpointObjectDeletion TRAP-TYPE -- info-TRAPTYPE: event -- info-TRAPID: 305 -- info-IMPL: V2.0-> ENTERPRISE xldv20Traps VARIABLES { xldv20TvTimeAndDate, xldv20pmTvAtmObjectIndex, xldv20pmTvEndpointType } DESCRIPTION " An Atm endpoint object is deleted. " ::= 305 END