-- MIB file created 05-May-2011 12:01:11, by -- SMICng version 2.2.11-beta(PRO)(Solaris), January 20, 2001. Enterprise key cisco.com CISCO-MPLS-TE-STD-EXT-MIB DEFINITIONS ::= BEGIN -- From file: "CISCO-MPLS-TE-STD-EXT-MIB.my" -- Compile options "4 7 F H N W 03 06 0B 0G 0N 0T" IMPORTS mplsTunnelIndex, mplsTunnelInstance, mplsTunnelIngressLSRId, mplsTunnelEgressLSRId FROM MPLS-TE-STD-MIB ciscoMgmt FROM CISCO-SMI Counter, Gauge FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212; cmplsTeStdExtMIB OBJECT IDENTIFIER ::= { ciscoMgmt 738 } -- MODULE-IDENTITY -- LastUpdated -- 201005270000Z -- OrgName -- Cisco Systems, Inc. -- ContactInfo -- Cisco Systems -- Customer Service -- Postal: 170 W Tasman Drive -- San Jose, CA 95134 -- USA -- Tel: +1 800 553-NETS -- E-mail: cs-snmp@cisco.com -- Descr -- This MIB module contains Cisco specific managed object -- definitions for MPLS Traffic Engineering (TE), not contained in -- MPLS-TE-STD-MIB. -- The auto bandwidth feature enables MPLS TE Tunnels to adapt -- automatically their bandwidth to their actual load. -- RevDate -- 201005270000Z -- RevDescr -- Initial version of this MIB module. cmplsTeStdExtMIBNotifs OBJECT IDENTIFIER ::= { cmplsTeStdExtMIB 0 } cmplsTeStdExtMIBObjects OBJECT IDENTIFIER ::= { cmplsTeStdExtMIB 1 } cmplsTeStdExtMIBConform OBJECT IDENTIFIER ::= { cmplsTeStdExtMIB 2 } cmplsTeStdExtMIBCompliances OBJECT IDENTIFIER ::= { cmplsTeStdExtMIBConform 1 } cmplsTeStdExtMIBGroups OBJECT IDENTIFIER ::= { cmplsTeStdExtMIBConform 2 } CmplsTunnelBWPercent ::= Gauge(0..100) -- TEXTUAL-CONVENTION -- DspHint -- d -- Status -- mandatory -- Descr -- A fraction of the bandwidth expressed in percentage. cmplsTunnelAutoBWTable OBJECT-TYPE SYNTAX SEQUENCE OF CmplsTunnelAutoBWEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table is used in order to manage auto bandwidth data. This table is sparse dependent on the mplsTunnelTable. An entry in this table exists for each mplsTunnelEntry with a mplsTunnelRole of 'head' or 'headTail'. Each row contains auto-bandwidth data for the tunnel identified by the indexes defined later. An entry is created as soon as a 'head' or 'headTail' MPLS TE tunnel is configured in the system." ::= { cmplsTeStdExtMIBObjects 1 } cmplsTunnelAutoBWEntry OBJECT-TYPE SYNTAX CmplsTunnelAutoBWEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A conceptual row in cmplsTunnelAutoBWTable. There is an entry in this table for each MPLS-TE tunnel with mplsTunnelRole equals to 'head' or 'headTail'." INDEX { mplsTunnelIndex, mplsTunnelInstance, mplsTunnelIngressLSRId, mplsTunnelEgressLSRId } ::= { cmplsTunnelAutoBWTable 1 } CmplsTunnelAutoBWEntry ::= SEQUENCE { cmplsTunnelAutoBWStatus INTEGER, cmplsTunnelAutoBWMin Gauge, cmplsTunnelAutoBWMax Gauge, cmplsTunnelAutoBWAdjThreshPercs CmplsTunnelBWPercent, cmplsTunnelAutoBWAdjThreshBW Gauge, cmplsTunnelAutoBWOverflowThreshPercs CmplsTunnelBWPercent, cmplsTunnelAutoBWOverflowThreshBW Gauge, cmplsTunnelAutoBWOverflowLimit Gauge, cmplsTunnelAutoBWUnderflowThreshPercs CmplsTunnelBWPercent, cmplsTunnelAutoBWUnderflowThreshBW Gauge, cmplsTunnelAutoBWUnderflowLimit Gauge, cmplsTunnelAutoBWApplicationFrequency Gauge, cmplsTunnelAutoBWCollectionFrequency Gauge, cmplsTunnelAutoBWLastAppliedBW Gauge, cmplsTunnelAutoBWApplications Counter, cmplsTunnelAutoBWLastApplicationTrigger INTEGER, cmplsTunnelAutoBWOverflowApplications Counter, cmplsTunnelAutoBWOverflowOccurrences Counter, cmplsTunnelAutoBWUnderflowApplications Counter, cmplsTunnelAutoBWUnderflowOccurrences Counter, cmplsTunnelAutoBWUnderflowHighestBW Gauge, cmplsTunnelAutoBWRequested Gauge, cmplsTunnelAutoBWSignaled Gauge, cmplsTunnelAutoBWCollectOnlyRequested Gauge, cmplsTunnelAutoBWHighest Gauge, cmplsTunnelAutoBWCollectedSamples Counter, cmplsTunnelAutoBWJitter Gauge, cmplsTunnelAutoBWAppRejectReason INTEGER } cmplsTunnelAutoBWStatus OBJECT-TYPE SYNTAX INTEGER { autoBWDisabled(1), autoBWEnabled(2), autoBWCollectOnlyMode(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the operational status [or mode] of the auto bandwidth algorithm: - autoBWDisabled: The auto-bandwidth algorithm is not running; - autoBWEnabled: The auto-bandwidth algorithm is running; - autoBWCollectOnlyMode: The auto-bandwidth algorithm is running, but the bandwidth applications are disabled;" DEFVAL { autoBWDisabled } ::= { cmplsTunnelAutoBWEntry 1 } cmplsTunnelAutoBWMin OBJECT-TYPE SYNTAX Gauge -- Units -- kbps ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the minimum bandwidth that the auto-bandwidth algorithm can apply to a tunnel when the adjustment threshold is overcome. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." DEFVAL { 0 } ::= { cmplsTunnelAutoBWEntry 2 } cmplsTunnelAutoBWMax OBJECT-TYPE SYNTAX Gauge -- Units -- kbps ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the maximum bandwidth that the auto-bandwidth algorithm can apply to a tunnel when the adjustment threshold is overcome. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." DEFVAL { 100 } ::= { cmplsTunnelAutoBWEntry 3 } cmplsTunnelAutoBWAdjThreshPercs OBJECT-TYPE SYNTAX CmplsTunnelBWPercent -- Rsyntax Gauge(0..100) ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the adjustment threshold percentage that needs to be overcome in order to trigger a new bandwidth application. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." DEFVAL { 10 } ::= { cmplsTunnelAutoBWEntry 4 } cmplsTunnelAutoBWAdjThreshBW OBJECT-TYPE SYNTAX Gauge -- Units -- kbps ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the adjustment threshold bandwidth that needs to be overcome in order to trigger a new bandwidth application. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." DEFVAL { 10 } ::= { cmplsTunnelAutoBWEntry 5 } cmplsTunnelAutoBWOverflowThreshPercs OBJECT-TYPE SYNTAX CmplsTunnelBWPercent -- Rsyntax Gauge(0..100) ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the adjustment threshold percentage that needs to be overcome in order to trigger an overflow occurrence. If the application period has not completed when a cmplsTunnelAutoBWOverflowLimit overflow has occurred, a new bandwidth will be applied. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." DEFVAL { 10 } ::= { cmplsTunnelAutoBWEntry 6 } cmplsTunnelAutoBWOverflowThreshBW OBJECT-TYPE SYNTAX Gauge -- Units -- kbps ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the adjustment threshold bandwidth that needs to be overcome in order to trigger an overflow occurrence. If the application period has not completed when a cmplsTunnelAutoBWOverflowLimit overflow has occurred, a new bandwidth will be applied. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." DEFVAL { 10 } ::= { cmplsTunnelAutoBWEntry 7 } cmplsTunnelAutoBWOverflowLimit OBJECT-TYPE SYNTAX Gauge ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the number of consecutive collections exceeding overflow threshold. If the application period has not completed when a cmplsTunnelAutoBWOverflowLimit overflow has occurred, a new bandwidth will be applied. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." DEFVAL { 1 } ::= { cmplsTunnelAutoBWEntry 8 } cmplsTunnelAutoBWUnderflowThreshPercs OBJECT-TYPE SYNTAX CmplsTunnelBWPercent -- Rsyntax Gauge(0..100) ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the adjustment threshold percentage that needs to be overcome in order to trigger an underflow occurrence. If the application period has not completed when a cmplsTunnelAutoBWUnderflowLimit underflow has occurred, a new bandwidth will be applied. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." DEFVAL { 10 } ::= { cmplsTunnelAutoBWEntry 9 } cmplsTunnelAutoBWUnderflowThreshBW OBJECT-TYPE SYNTAX Gauge -- Units -- kbps ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the adjustment threshold bandwidth that needs to be overcome in order to trigger an underflow occurrence. If the application period has not completed when a cmplsTunnelAutoBWUnderflowLimit underflow has occurred, a new bandwidth will be applied. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." DEFVAL { 1 } ::= { cmplsTunnelAutoBWEntry 10 } cmplsTunnelAutoBWUnderflowLimit OBJECT-TYPE SYNTAX Gauge ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the number of consecutive collections under the underflow threshold. If the application period has not completed when a cmplsTunnelAutoBWUnderflowLimit underflow has occurred, a new bandwidth will be applied. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." DEFVAL { 1 } ::= { cmplsTunnelAutoBWEntry 11 } cmplsTunnelAutoBWApplicationFrequency OBJECT-TYPE SYNTAX Gauge -- Units -- seconds ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the bandwidth application period. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." DEFVAL { 300 } ::= { cmplsTunnelAutoBWEntry 12 } cmplsTunnelAutoBWCollectionFrequency OBJECT-TYPE SYNTAX Gauge -- Units -- seconds ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the sampling period for data rates. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." DEFVAL { 300 } ::= { cmplsTunnelAutoBWEntry 13 } cmplsTunnelAutoBWLastAppliedBW OBJECT-TYPE SYNTAX Gauge -- Units -- kbps ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the last bandwidth applied by the auto-bandwidth algorithm. It will be set to zero if no bandwidth has been applied yet. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." ::= { cmplsTunnelAutoBWEntry 14 } cmplsTunnelAutoBWApplications OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the number of auto bandwidths applied. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." ::= { cmplsTunnelAutoBWEntry 15 } cmplsTunnelAutoBWLastApplicationTrigger OBJECT-TYPE SYNTAX INTEGER { applicationNone(1), applicationPeriodic(2), applicationManual(3), applicationOverflow(4), applicationUnderflow(5) } ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the trigger reason for the last bandwidth application. If mplsTunnelInstance is zero this object will be set to 'applicationNone'. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." ::= { cmplsTunnelAutoBWEntry 16 } cmplsTunnelAutoBWOverflowApplications OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the number of bandwidth applications due to overflow occurrences. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." ::= { cmplsTunnelAutoBWEntry 17 } cmplsTunnelAutoBWOverflowOccurrences OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the number of overflow occurrences since last application period. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." ::= { cmplsTunnelAutoBWEntry 18 } cmplsTunnelAutoBWUnderflowApplications OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the number of bandwidth applications due to underflow occurrences. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." ::= { cmplsTunnelAutoBWEntry 19 } cmplsTunnelAutoBWUnderflowOccurrences OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the number of underflow occurrences since last application period. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." ::= { cmplsTunnelAutoBWEntry 20 } cmplsTunnelAutoBWUnderflowHighestBW OBJECT-TYPE SYNTAX Gauge -- Units -- kbps ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the highest sample collected during an underflow sequence. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." ::= { cmplsTunnelAutoBWEntry 21 } cmplsTunnelAutoBWRequested OBJECT-TYPE SYNTAX Gauge -- Units -- kpbs ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the bandwidth requested by the auto-bandwidth algorithm. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." ::= { cmplsTunnelAutoBWEntry 22 } cmplsTunnelAutoBWSignaled OBJECT-TYPE SYNTAX Gauge -- Units -- kpbs ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the bandwidth signaled by the auto-bandwidth algorithm. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." ::= { cmplsTunnelAutoBWEntry 23 } cmplsTunnelAutoBWCollectOnlyRequested OBJECT-TYPE SYNTAX Gauge -- Units -- kpbs ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the bandwidth that would have been requested by the auto-bandwidth algorithm if the auto-bandwidth functionality was enabled. If the collect only mode is enabled, the bandwidth change request will not be executed. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." ::= { cmplsTunnelAutoBWEntry 24 } cmplsTunnelAutoBWHighest OBJECT-TYPE SYNTAX Gauge -- Units -- kpbs ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the highest bandwidth sampled by the auto-bandwidth algorithm. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." ::= { cmplsTunnelAutoBWEntry 25 } cmplsTunnelAutoBWCollectedSamples OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the samples collected since the last auto-bandwidth application. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." ::= { cmplsTunnelAutoBWEntry 26 } cmplsTunnelAutoBWJitter OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the auto-bandwidth application jitter. Jitter is the extra time to be added to the application interval the first time the auto bandwidth is applied. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." DEFVAL { 0 } ::= { cmplsTunnelAutoBWEntry 27 } cmplsTunnelAutoBWAppRejectReason OBJECT-TYPE SYNTAX INTEGER { applicationAllowed(1), autoBWDisabled(2), tunnelIsDown(3), tunnelIsFRR(4), tunnelIsBackup(5), tunnelIsLockDown(6) } ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the reason for the bandwidth application rejection. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." ::= { cmplsTunnelAutoBWEntry 28 } cmplsTeStdExtMIBAutoBWObjectGroup OBJECT IDENTIFIER ::= { cmplsTeStdExtMIBGroups 1 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- This contains the main MPLS TE extensions groups. -- objects -- cmplsTunnelAutoBWStatus, cmplsTunnelAutoBWMin, -- cmplsTunnelAutoBWMax, cmplsTunnelAutoBWAdjThreshPercs, -- cmplsTunnelAutoBWAdjThreshBW, -- cmplsTunnelAutoBWApplicationFrequency, -- cmplsTunnelAutoBWCollectionFrequency, -- cmplsTunnelAutoBWLastAppliedBW, cmplsTunnelAutoBWApplications, -- cmplsTunnelAutoBWLastApplicationTrigger, -- cmplsTunnelAutoBWOverflowApplications, -- cmplsTunnelAutoBWOverflowOccurrences, -- cmplsTunnelAutoBWUnderflowApplications, -- cmplsTunnelAutoBWUnderflowOccurrences, -- cmplsTunnelAutoBWUnderflowHighestBW, -- cmplsTunnelAutoBWRequested, cmplsTunnelAutoBWSignaled, -- cmplsTunnelAutoBWCollectOnlyRequested, -- cmplsTunnelAutoBWHighest, cmplsTunnelAutoBWCollectedSamples, -- cmplsTunnelAutoBWAppRejectReason cmplsTeStdExtMIBAutoBWOptionalGroup OBJECT IDENTIFIER ::= { cmplsTeStdExtMIBGroups 2 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- This contains the optional MPLS TE extensions groups. -- objects -- cmplsTunnelAutoBWOverflowThreshPercs, -- cmplsTunnelAutoBWOverflowThreshBW, -- cmplsTunnelAutoBWOverflowLimit, -- cmplsTunnelAutoBWUnderflowThreshPercs, -- cmplsTunnelAutoBWUnderflowThreshBW, -- cmplsTunnelAutoBWUnderflowLimit, cmplsTunnelAutoBWJitter cmplsTeStdExtMIBCompliance OBJECT IDENTIFIER ::= { cmplsTeStdExtMIBCompliances 1 } -- MODULE-COMPLIANCE -- Status -- mandatory -- Descr -- This is the main compliance statement for the MIB. -- Module -- >>current<< -- OptGroup -- cmplsTeStdExtMIBAutoBWOptionalGroup -- OptGroup -- cmplsTeStdExtMIBAutoBWObjectGroup END