EFDATA-SPECTRACAST-DR5000-MIB DEFINITIONS ::= BEGIN -- generic definitions of types and Efdata client MIB -- placement on general SNMP tree IMPORTS enterprises, IpAddress, Counter, OBJECT-TYPE FROM SNMPv2-SMI DisplayString FROM RFC1213-MIB; efdata OBJECT IDENTIFIER ::= { enterprises 6247 } spectracast OBJECT IDENTIFIER ::= { efdata 3 } DR5000 OBJECT IDENTIFIER ::= { spectracast 2 } general OBJECT IDENTIFIER ::= { DR5000 1 } MPEG-PID-mode ::= INTEGER { manual(1), automatic(2) } FLAG ::= INTEGER { on(1), off(2) } -- lns definitions SoftwareVersion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Software Version (read only)." ::={ general 1 } HardwareVersion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Hardware Version (read only)." ::={ general 2 } MacAddress OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "MAC address (read only)." ::={ general 3 } MulticastRoutingStatus OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Multicast routing status (read only)." ::={ general 4 } RFparameters OBJECT IDENTIFIER ::= { DR5000 2 } RF-Input OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "RF Input frequency (MHz) (read-write)." ::={ RFparameters 1 } LNB-Frequency OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "LNB frequency (GHz) (read-write)." ::={ RFparameters 2 } SymbolRate OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Symbol rate (Msps) (read-write)." ::={ RFparameters 3 } Polarity OBJECT-TYPE SYNTAX INTEGER { Disabled(0), Vertical(14), Horizontal(18) } ACCESS read-write STATUS mandatory DESCRIPTION "Polarity may take values: Disabled(0), Vertical(14) or Horizontal(18) (read-write)." ::={ RFparameters 4 } FrequencyRange OBJECT-TYPE SYNTAX INTEGER { Low(0), High(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Frequency range may take values: Low(0) or High(1) (read-write)." ::= { RFparameters 5 } DVBparameters OBJECT IDENTIFIER ::= { DR5000 3 } PIDs-number OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of PIDs in the list (read only)." ::={ DVBparameters 1 } pidTable OBJECT-TYPE SYNTAX SEQUENCE OF PIDentry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of PID entries. The number of entries is given by PIDs-number value." ::= { DVBparameters 2 } pidEntry OBJECT-TYPE SYNTAX PIDentry ACCESS not-accessible STATUS mandatory DESCRIPTION "PID entry containing objects for the particular PID." INDEX { pidindex } ::= { pidTable 1 } PIDentry ::= SEQUENCE { pidindex INTEGER, pidvalue INTEGER } pidindex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Unique ID for each PID, ranges between 1 and PIDs-number (read-only)." ::= { pidEntry 1 } pidvalue OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Unique PID value (read-write)." ::= { pidEntry 2 } CCUparameters OBJECT IDENTIFIER ::= { DR5000 4 } CcuConnectionMode OBJECT-TYPE SYNTAX INTEGER { Manual(0), Duplex(1), Simplex(2) } ACCESS read-write STATUS mandatory DESCRIPTION "CCU connection mode, may take values: Manual(0), Duplex(1) or Simplex(2) (read-write)." ::={ CCUparameters 1 } CcuIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "CCU IP Address (read-write)." ::={ CCUparameters 2 } CcuUserName OBJECT-TYPE SYNTAX DisplayString ACCESS write-only STATUS mandatory DESCRIPTION "User name for connecting to the CCU (write only)." ::={ CCUparameters 3 } CcuPassword OBJECT-TYPE SYNTAX DisplayString ACCESS write-only STATUS mandatory DESCRIPTION "Password for connecting to the CCU (write only)." ::={ CCUparameters 4 } EncryptedMulticast OBJECT-TYPE SYNTAX INTEGER { Disabled(0), Enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Set to Enabled in order to receive encrypted multicast." ::={ CCUparameters 5 } Dialupparameters OBJECT IDENTIFIER ::= { DR5000 5 } ConnectionMode OBJECT-TYPE SYNTAX INTEGER { Manual(0), Automatic(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Connection Mode, may take values: Manual(0) or Automatic(1) (read-write)." ::={ Dialupparameters 1 } PhoneNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "ISP Phone number, accepts only digits (read-write)." ::={ Dialupparameters 2 } UserName OBJECT-TYPE SYNTAX DisplayString ACCESS write-only STATUS mandatory DESCRIPTION "User name for dialup connection (write only)." ::={ Dialupparameters 3 } Password OBJECT-TYPE SYNTAX DisplayString ACCESS write-only STATUS mandatory DESCRIPTION "Password for dialup connection (write only)." ::={ Dialupparameters 4 } DialTone OBJECT-TYPE SYNTAX INTEGER { Tone(0), Pulse(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Dialing mode, may take values: Tone(0)) or Pulse(1) (read-write)." ::={ Dialupparameters 5 } Speed OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Modem connection speed, may take values: 9600, 19200, 38400, 57600 or 115200 (read-write)." ::={ Dialupparameters 7 } IdleTimeOut OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Dial on demand time out in minutes. Set to 0 in order to disable dial on demand (read-write)." ::={ Dialupparameters 8 } Authentication OBJECT-TYPE SYNTAX INTEGER { PAP(0), CHAP(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Authentication mode, may take values: PAP or CHAP (read-write)." ::={ Dialupparameters 9 } Status OBJECT IDENTIFIER ::= { DR5000 6 } InitializationStatus OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Card initialization status (read only)." ::={ Status 1 } DemodulatorStatus OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Current demodulator status (read only)." ::={ Status 2 } SpectralInversion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Spectral inversion (read only)." ::={ Status 3 } BER-before-Err-Correction OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "BER before error correction (read only)." ::={ Status 4 } FEC OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "FEC (read only)." ::={ Status 5 } AGC OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Gain value set by AGC (Db) (read only)." ::={ Status 6 } FrequencyOffset OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Frequency offset (read only)." ::={ Status 7 } Eb-N0 OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Eb/N0 (read only)." ::={ Status 8 } CCU-connection-status OBJECT-TYPE SYNTAX INTEGER { Disconnected(0), Connected(1), TryingToConnect(2), WaitingForDialup(3), WaitingForRFLock(4) } ACCESS read-only STATUS mandatory DESCRIPTION "CCU connection status, may take values Disconnected(0), Connected(1), Trying to Connect(2), Waiting for Dialup(3), or Waiting for RF Lock(4) (read only)." ::={ Status 9 } Dialup-connection-status OBJECT-TYPE SYNTAX INTEGER { Disconnected(0), Connected(1), TryingToConnect(2), Idle(10) } ACCESS read-only STATUS mandatory DESCRIPTION "Dialup connection status, may take values Disconnected(0), Connected(1), Trying to Connect(2) or Idle(10) (read only)." ::={ Status 10 } FlowStatistics OBJECT IDENTIFIER ::= { DR5000 7 } TotalThroughput OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Total throughput in bytes/sec. (read only)." ::={ FlowStatistics 1 } UnicastThroughput OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Unicast throughput in bytes/sec. (read only)." ::={ FlowStatistics 2 } MulticastThroughput OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Multicast throughput in bytes/sec. (read only)." ::={ FlowStatistics 3 } TotalPackets OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Total packets received since reset (read only)." ::={ FlowStatistics 4 } BadPackets OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Bad RS packets (read only)." ::={ FlowStatistics 5 } CorrectedPackets OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Corrected RS packets (read only)." ::={ FlowStatistics 6 } ResetFlowStatistics OBJECT-TYPE SYNTAX INTEGER { False(0), True(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Set to True in order to reset flow statistics." ::={ FlowStatistics 7 } Maintenance OBJECT IDENTIFIER ::= { DR5000 8 } DriverRestart OBJECT-TYPE SYNTAX INTEGER { False(0), True(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Set to True in order to restart the Driver." ::={ Maintenance 1 } DialupConnect OBJECT-TYPE SYNTAX INTEGER { False(0), True(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Set to True in order to dial your ISP." ::={ Maintenance 2 } DialupDisconnect OBJECT-TYPE SYNTAX INTEGER { False(0), True(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Set to true in order to disconnect from your ISP." ::={ Maintenance 3 } CCUconnect OBJECT-TYPE SYNTAX INTEGER { False(0), True(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Set to True in order to connect to the CCU." ::={ Maintenance 4 } CCUdisconnect OBJECT-TYPE SYNTAX INTEGER { False(0), True(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Set to True in order to disconnect from the CCU." ::={ Maintenance 5 } Upgrade OBJECT-TYPE SYNTAX DisplayString ACCESS write-only STATUS mandatory DESCRIPTION "Set to the upgrade file name, and upgrade the system. After upgrade finishes the system reboots automatically (write only)." ::={ Maintenance 6 } SNMPVariables OBJECT IDENTIFIER ::= { DR5000 9 } EnableTraps OBJECT-TYPE SYNTAX INTEGER { Disable(0), Enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Set to True in order to start getting traps." ::={ SNMPVariables 1 } SNMPManagerIP OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP address of SNMP manager where traps have to be sent to (read-write)." ::={ SNMPVariables 2 } TrapPeriod OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Trap sending period in seconds (read-write)." ::={ SNMPVariables 3 } TrapList OBJECT IDENTIFIER ::= { SNMPVariables 4 } MulticastDaemon OBJECT IDENTIFIER ::= { TrapList 1 } MulticastTrapEnable OBJECT-TYPE SYNTAX INTEGER { Disable(0), Enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Use multicast daemon status trap. A trap message is sent when multicast daemon goes down (read-write)." ::={ MulticastDaemon 1 } Demodulator OBJECT IDENTIFIER ::= { TrapList 2 } DemodulatorTrapEnable OBJECT-TYPE SYNTAX INTEGER { Disable(0), Enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Use demodulator status trap. A trap message is sent when the demodulator loses data lock (read-write)." ::={ Demodulator 1 } CCUConnection OBJECT IDENTIFIER ::= { TrapList 3 } CCUTrapEnable OBJECT-TYPE SYNTAX INTEGER { Disable(0), Enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Use CCU connection status trap. A trap message is sent when CCU status changes from Connected to any other one (read-write)." ::={ CCUConnection 1 } Dialup OBJECT IDENTIFIER ::= { TrapList 4 } DialupTrapEnable OBJECT-TYPE SYNTAX INTEGER { Disable(0), Enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Use dialup connection status trap. A trap message is sent when dialup status changes from Connected to any other one except Idle (read-write)." ::={ Dialup 1 } BERLevel OBJECT IDENTIFIER ::= { TrapList 5 } BERTrapEnable OBJECT-TYPE SYNTAX INTEGER { Disable(0), Enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Use BER level trap. A trap message is sent when BER value is greater then BER trap threshold (read-write)." ::={ BERLevel 1 } BERThreshold OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "BER level threshold value (read-write)." ::={ BERLevel 2 } FreqOffset OBJECT IDENTIFIER ::= { TrapList 6 } FreqOffsetTrapEnable OBJECT-TYPE SYNTAX INTEGER { Disable(0), Enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Use frequency offset trap. A trap message is sent when absolute frequency offset is greater then frequency offset trap threshold (read-write)." ::={ FreqOffset 1 } FreqOffsetThreshold OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Frequency offset threshold value (read-write)." ::={ FreqOffset 2 } AGCLevel OBJECT IDENTIFIER ::= { TrapList 7 } AGCTrapEnable OBJECT-TYPE SYNTAX INTEGER { Disable(0), Enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Use AGC level trap. A trap message is sent when gain value is greater then AGC trap threshold (read-write)." ::={ AGCLevel 1 } AGCThreshold OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "AGC threshold value (read-write)" ::={ AGCLevel 2 } END