-- MIB file created 31-Jan-2011 04:59:11, by -- SMICng version 2.2.11-beta(PRO)(Solaris), January 20, 2001. Enterprise key cisco.com CISCO-PTP-MIB DEFINITIONS ::= BEGIN -- From file: "CISCO-PTP-MIB.my" -- Compile options "4 7 F H N W 03 06 0B 0G 0N 0T" IMPORTS TruthValue, DisplayString FROM SNMPv2-TC-v1 InetAddressType, InetAddress FROM INET-ADDRESS-MIB InterfaceIndexOrZero FROM CISCO-TC ciscoMgmt FROM CISCO-SMI Counter, Gauge FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212; ciscoPtpMIB OBJECT IDENTIFIER ::= { ciscoMgmt 760 } -- MODULE-IDENTITY -- LastUpdated -- 201101280000Z -- OrgName -- Cisco Systems, Inc. -- ContactInfo -- Cisco Systems -- Customer Service -- -- Postal: 170 W Tasman Drive -- San Jose, CA 95134 -- USA -- -- Tel: +1 800 553-NETS -- -- E-mail: cs-@cisco.com -- Descr -- The MIB module for PTPv2 (IEEE1588 - 2008) -- -- Overview of PTPv2 (IEEE 1588-2008) -- -- This IEEE standard defines a protocol enabling precise -- synchronization of clocks in measurement and control systems -- implemented with packet-based networks, the IEEE Standard PTPv2 -- 1588 (2008). This MIB does not address the standard IEEE -- 1588 (2002). The protocol is applicable to network elements -- communicating using IP. The protocol enables heterogeneous -- systems that include clocks of various inherent precision, -- resolution, and stability to synchronize to a grandmaster -- clock. -- The protocol supports system-wide synchronization accuracy in -- the sub-microsecond range with minimal network and local clock -- computing resources. The standard uses UDP/IP. It includes -- formal mechanisms for message extensions, higher sampling -- rates, correction for asymmetry, a clock type to reduce error -- accumulation in large topologies, and specifications on how to -- incorporate the resulting additional data into the -- synchronization protocol. The standard defines conformance and -- management capability also. -- -- MIB description -- -- This MIB is to support the Precision Timing Protocol (PTP) -- feature of Cisco System devices. -- -- Acronyms: -- ARB arbitrary -- BMC best master clock -- CAN Controller Area Network -- CP Communication Profile -- [according to IEC 61784-1:200710] -- CPF Communication Profile Family -- [according to IEC 61784-1:2007] -- DS Differentiated Service -- E2E End-to-End -- E2ETC End-to-End Transparent Clock -- EUI Extended Unique Identifier. -- FFO Fractional Frequency Offset -- GPS Global Positioning System -- IANA Internet Assigned Numbers Authority -- ICV Integrity Check Value -- ID Identification -- IPv4 Internet Protocol version 4 -- IPv6 Internet Protocol version 6 -- JD Julian Date -- JDN Julian Day Number -- MAC Media Access Control -- [according to IEEE Std 802.3-2005] -- MJD Modified Julian Day -- NIST National Institute of Standards and -- Technology (see www.nist.gov) -- NTP Network Time Protocol (see IETF RFC 1305 -- [B7]) -- OUI Organizational Unique Identifier(allocated -- by -- the IEEE) -- P2P Peer-to-Peer -- P2PTC Peer-To-Peer Transparent Clock -- PHY physical layer [according to IEEE Std -- 802.3-2005] -- POSIX Portable Operating System Interface -- (see ISO/IEC 9945:2003) -- PPS Pulse per Second -- PTP Precision Time Protocol -- SA Security Associations -- SNTP Simple Network Time Protocol -- SOF Start of Frame -- TAI International Atomic Time -- TC Traffic Class -- TC Transparent Clock -- TLV Type, Length, Value [according to IEEE Std -- 802.1AB] -- ToD Time of Day Synchronization -- ToS Type of Service -- UCMM UnConnect Message Manager -- UDP/IP User Datagram Protocol -- UTC Coordinated Universal Time -- -- References: -- [1] Precision clock synchronization protocol for networked -- measurement and control systems - IEC 61588 IEEE 1588(tm) -- Edition 2.0 2009-02 -- -- -- Definitions from [1] section 3.1 -- -- Accuracy: -- The mean of the time or frequency error between the clock under -- test and a perfect reference clock, over an ensemble of -- measurements. Stability is a measure of how the mean varies -- with respect to variables such as time, temperature, and so on. -- -- The precision is a measure of the deviation of the error from -- the mean. -- -- Atomic process: -- A process is atomic if the values of all inputs to the process -- are not permitted to change until all of the results of the -- process are instantiated, and the outputs of the process are -- not visible to other processes until the processing of each -- output is complete. -- -- Boundary clock: -- A clock that has multiple Precision Time Protocol(PTP) ports in -- a domain and maintains the timescale used in the domain. It -- may serve as the source of time, i.e., be a master clock, and -- may synchronize to another clock, i.e., be a slave clock. -- -- Boundary node clock: -- A clock that has multiple Precision Time Protocol(PTP) ports in -- a domain and maintains the timescale used in the domain. It -- differs from the boundary clock in that the clock roles can -- change. -- -- Clock: -- A node participating in the Precision Time Protocol (PTP) that -- is capable of providing a measurement of the passage of time -- since a defined epoch. -- -- Domain: -- A logical grouping of clocks that synchronize to each other -- using the protocol, but that are not necessarily synchronized -- to clocks in another domain. -- -- End-to-end transparent clock: -- A transparent clock that supports the use of the end-to-end -- delay measurement mechanism between slave clocks and the master -- clock. Each node must measure the residence time of PTP event -- messages and accumulate it in Correction Field. -- -- Epoch: -- The origin of a timescale. -- -- Event: -- An abstraction of the mechanism by which signals or conditions -- are generated and represented. -- -- Foreign master: -- An ordinary or boundary clock sending Announce messages to -- another clock that is not the current master recognized by the -- other clock. -- -- Grandmaster clock: -- Within a domain, a clock that is the ultimate source of time -- for clock synchronization using the protocol. -- -- Holdover: -- A clock previously synchronized/syntonized to another clock -- (normally a primary reference or a master clock) but now -- free-running based on its own internal oscillator, whose -- frequency is being adjusted using data acquired while it had -- been synchronized/syntonized to the other clock. It is said to -- be in holdover or in the holdover mode, as long as it is within -- its accuracy requirements. -- -- Link: -- A network segment between two Precision Time Protocol ports -- supporting the peer delay mechanism of this standard. The peer -- delay mechanism is designed to measure the propagation time -- over such a link. -- -- Management node: -- A device that configures and monitors clocks. -- -- Master clock: -- In the context of a single Precision Time Protocol -- communication path, a clock that is the source of time to which -- all other clocks on that path synchronize. -- -- Message timestamp point: -- A point within a Precision Time Protocol event message serving -- as a reference point in the message. A timestamp is defined by -- the instant a message timestamp point passes the reference -- plane of a clock. -- -- Multicast communication: -- A communication model in which each Precision Time Protocol -- message sent from any PTP port is capable of being received and -- processed by all PTP ports on the same PTP communication path. -- -- Node: -- A device that can issue or receive Precision Time Protocol -- communications on a network. -- -- One-step clock: -- A clock that provides time information using a single event -- message. -- -- On-pass support: -- Indicates that each node in the synchronization chain from -- master to slave can support IEEE-1588. -- -- Ordinary clock: -- A clock that has a single Precision Time Protocol port in a -- domain and maintains the timescale used in the domain. It may -- serve as a source of time, i.e., be a master clock, or may -- synchronize to another clock, i.e., be a slave clock. -- -- Parent clock: -- The master clock to which a clock is synchronized. -- -- -- Peer-to-peer transparent clock: -- A transparent clock that, in addition to providing Precision -- Time Protocol event transit time information, also provides -- corrections for the propagation delay of the link connected to -- the port receiving the PTP event message. In the presence of -- peer-to-peer transparent clocks, delay measurements between -- slave clocks and the master clock are performed using the -- peer-to-peer delay measurement mechanism. -- -- -- Phase change rate: -- The observed rate of change in the measured time with respect -- to the reference time. The phase change rate is equal to the -- fractional frequency offset between the measured frequency and -- the reference frequency. -- -- PortNumber: -- An index identifying a specific Precision Time Protocol port on -- a PTP node. -- -- Primary reference: -- A source of time and or frequency that is traceable to -- international standards. -- -- Profile: -- The set of allowed Precision Time Protocol features applicable -- to a device. -- -- Precision Time Protocol communication: -- Information used in the operation of the protocol, transmitted -- in a PTP message over a PTP communication path. -- -- Precision Time Protocol communication path: The signaling path -- portion of a particular network enabling direct communication -- among ordinary and boundary clocks. -- -- Precision Time Protocol node: -- PTP ordinary, boundary, or transparent clock or a device that -- generates or parses PTP messages. -- -- Precision Time Protocol port: -- A logical access point of a clock for PTP communications to the -- communications network. -- -- Recognized standard time source: -- A recognized standard time source is a source external to -- Precision Time Protocol that provides time and/or frequency as -- appropriate that is traceable to the international standards -- laboratories maintaining clocks that form the basis for the -- International Atomic Time and Universal Coordinated Time -- timescales. Examples of these are Global Positioning System, -- NTP, and National Institute of Standards and Technology (NIST) -- timeservers. -- -- Requestor: -- The port implementing the peer-to-peer delay mechanism that -- initiates the mechanism by sending a Pdelay_Req message. -- -- Responder: -- The port responding to the receipt of a Pdelay_Req message as -- part of the operation of the peer-to-peer delay mechanism. -- -- Synchronized clocks: -- Two clocks are synchronized to a specified uncertainty if they -- have the same epoch and their measurements of the time of a -- single event at an arbitrary time differ by no more than that -- uncertainty. -- -- Syntonized clocks: -- Two clocks are syntonized if the duration of the second is the -- same on both, which means the time as measured by each advances -- at the same rate. They may or may not share the same epoch. -- -- Time of Day: -- -- -- Timeout: -- A mechanism for terminating requested activity that, at least -- from the requester's perspective, does not complete within the -- specified time. -- -- Timescale: -- A linear measure of time from an epoch. -- -- Traceability: -- A property of the result of a measurement or the value of a -- standard whereby it can be related to stated references, -- usually national or international standards, through an unbroken -- chain of comparisons all having stated uncertainties. -- -- Translation device: -- A boundary clock or, in some cases, a transparent clock that -- translates the protocol messages between regions implementing -- different transport and messaging protocols, between different -- versions of IEEE Std 1588-2008/IEC 61588:2009, or different -- Precision Time Protocol profiles. -- -- transparent clock: -- A device that measures the time taken for a Precision Time -- Protocol event message to transit the device and provides this -- information to clocks receiving this PTP event message. -- -- Two-step clock: -- A clock that provides time information using the combination of -- an event message and a subsequent general message. -- -- The below table specifies the object formats of the various -- textual conventions used. -- -- Data type mapping Textual Convention SYNTAX -- ==================== ================== ===================== -- 5.3.2 TimeInterval ClockTimeInterval OCTET -- STRING(SIZE(1..255)) -- 5.3.3 Timestamp ClockTimestamp OCTET STRING(SIZE(6)) -- 5.3.4 ClockIdentity ClockIdentity OCTET -- STRING(SIZE(1..255)) -- 5.3.5 PortIdentity ClockPortNumber INTEGER(1..65535) -- 5.3.7 ClockQuality ClockQualityClassType -- -- Simple master-slave hierarchy [1] section 6.6.2.4 -- -- =============== -- - Ordinary - -- - Clock(1) - -- - GrandMaster - -- =======M======= -- | -- 1 -- | -- =======S=============================== -- - Boundary - -- - Clock(1) - -- ==============M==================M===== -- | | -- 2 3 -- | | -- =====S====== =======S================== -- - Ordinary - - Boundary - -- - Clock(2) - - Clock(2) - -- ============ =====M=============M====== -- | | -- 4 5 -- | | -- =====S====== =====S====== -- - Ordinary - - Ordinary - -- - Clock(3) - - Clock(4) - -- ============ ============ -- -- Grandmaster -- -- Boundary Clock(0-N) Ordinary Clocks(0-N) -- Ordinary Clocks(0-N) -- -- -- Relationship cardinality -- PTP system 1 : N PTP Clock -- PTP Clock 1 : 1 Domain -- PTP Clock 1 : N PTP Ports -- PTP Port N : N Physical Port (interface in IF-MIB) -- -- Transparent clock diagram from section 6.7.1.3 of [1] -- -- -- +============================+ -- | Boundary clock - 1 | -- +============================+ -- | | -- | | -- +== A ==+ B -- | | -- +=====================+ | -- | Ordinary clock - 1| | -- +=====================+ | -- +======================+ -- +==============+ | End-to-end | -- | Ordinary |==================| transparent clock- | -- | clock 1-1 | | 1 - 1 | -- +==============+ +======================+ -- | -- | -- C -- | -- | -- +======================+ -- +==============+ | End-to-end | -- | Ordinary |==================| transparent clock- | -- | clock 1-2 | | 1 - 2 | -- +==============+ +======================+ -- -- -- The MIB refers to the sections of the IEEE 1588 standard for -- reference. Throughout the MIB various secions from the standard -- are referenced -- RevDate -- 201101280000Z -- RevDescr -- Initial Version ciscoPtpMIBNotifs OBJECT IDENTIFIER ::= { ciscoPtpMIB 0 } ciscoPtpMIBObjects OBJECT IDENTIFIER ::= { ciscoPtpMIB 1 } ciscoPtpMIBConformance OBJECT IDENTIFIER ::= { ciscoPtpMIB 2 } ciscoPtpMIBSystemInfo OBJECT IDENTIFIER ::= { ciscoPtpMIBObjects 1 } ciscoPtpMIBCompliances OBJECT IDENTIFIER ::= { ciscoPtpMIBConformance 1 } ciscoPtpMIBGroups OBJECT IDENTIFIER ::= { ciscoPtpMIBConformance 2 } ciscoPtpMIBClockInfo OBJECT IDENTIFIER ::= { ciscoPtpMIBObjects 2 } ClockDomainType ::= Gauge(0..255) -- TEXTUAL-CONVENTION -- DspHint -- d -- Status -- mandatory -- Descr -- The Domain is identified by an integer, the domainNumber, in -- the range of 0 to 255. An integer value that is used to assign -- each PTP device to a particular domain. The following values -- define the valid domains. [1] Section 7.1 Domains Table 2 -- -- Value definition. -- ========= =================== -- 0 Default domain -- 1 Alternate domain 1 -- 2 Alternate domain 2 -- 3 Alternate domain 3 -- 4 - 127 User-defined domains -- 128 - 255 Reserved -- Refer -- Section 7.1 Domains and Table 2 of [1] ClockIdentity ::= OCTET STRING(SIZE(1..255)) -- TEXTUAL-CONVENTION -- Status -- mandatory -- Descr -- The clock Identity is an 8-octet array and will be presented in -- the form of a character array. The value of the -- ClockIdentity should be taken from the IEEE EUI-64 individual -- assigned numbers as indicated in Section 7.5.2.2.2 of [1]. The -- EUI-64 address is divided into the following fields. -- -- OUI byte[0-2] -- Extension identifier bytes:[3-7] -- -- The clock identifier can be constructed from existing EUI-48 -- assignments and here is an abbreviated example extracted from -- section 7.5.2.2.2 [1]. -- -- Company EUI-48 = 0xACDE4823456716 -- EUI-64 = ACDE48FFFE23456716 -- -- It is important to note the IEEE Registration Authority has -- deprecated the use of MAC-48 in any new design. -- Refer -- Section 7.5.2.2.1 from [1] ClockIntervalBase2 ::= INTEGER(-128..127) -- TEXTUAL-CONVENTION -- DspHint -- d -- Status -- mandatory -- Descr -- The interval included in message types Announce, Sync, -- Delay_Req, and Pdelay_Req as indicated in section 7.7.2.1 of -- [1]. -- -- The mean time interval between successive messages shall be -- represented as the logarithm to the base 2 of this time -- interval measured in seconds on the local clock of the device -- sending the message. The values of these logarithmic attributes -- shall be selected from integers in the range -128 to 127 subject -- to further limits established in an applicable PTP profile. -- Refer -- Section 7.7.2.1 General interval specification of [1] ClockMechanismType ::= INTEGER { e2e(1), p2p(2), disabled(254) } -- TEXTUAL-CONVENTION -- Status -- mandatory -- Descr -- The clock type based on whether End to End or peer to peer -- mechanisms are used. The mechanism used to calculate the Mean -- Path Delay as indicated in Table 9 of IEEE 1588-2008. -- -- Delay mechanism Value(hex) Specification -- E2E 01 The port is configured to use -- the delay request-response -- mechanism. -- -- P2P 02 The port is configured to use -- the peer delay mechanism. -- -- DISABLED FE The port does not implement -- the delay mechanism. -- Refer -- Sections 8.2.5.4.4, 6.6.4 and 7.4.2 of [1]. ClockInstanceType ::= Gauge(0..255) -- TEXTUAL-CONVENTION -- DspHint -- d -- Status -- mandatory -- Descr -- The instance of the Clock of a given clock type in a given -- domain. ClockPortNumber ::= Gauge(0..65535) -- TEXTUAL-CONVENTION -- DspHint -- d -- Status -- mandatory -- Descr -- An index identifying a specific Precision Time Protocol (PTP) -- port on a PTP node. -- Refer -- Section 7.5.2.3 Port Number and 5.3.5 of [1] ClockPortState ::= INTEGER { initializing(1), faulty(2), disabled(3), listening(4), preMaster(5), master(6), passive(7), uncalibrated(8), slave(9) } -- TEXTUAL-CONVENTION -- Status -- mandatory -- Descr -- This is the value of the current state of the protocol engine -- associated with this port. -- Port state Value Description -- =========================================================== -- initializing 1 In this state a port initializes -- its data sets, hardware, and -- communication facilities. -- faulty 2 The fault state of the protocol. -- disabled 3 The port shall not place any -- messages on its communication path. -- listening 4 The port is waiting for the -- announceReceiptTimeout to expire or -- to receive an Announce message from -- a master. -- preMaster 5 The port shall behave in all respects -- as though it were in the MASTER state -- except that it shall not place any -- messages on its communication path -- except for Pdelay_Req, Pdelay_Resp, -- Pdelay_Resp_Follow_Up, signaling, or -- management messages. -- master 6 The port is behaving as a master -- port. -- passive 7 The port shall not place any -- messages on its communication path -- except for Pdelay_Req, Pdelay_Resp, -- Pdelay_Resp_Follow_Up, or signaling -- messages, or management messages -- that are a required response to -- another management message -- uncalibrated 8 The local port is preparing to -- synchronize to the master port. -- slave 9 The port is synchronizing to the -- selected master port. -- Refer -- Section 8.2.5.3.1 portState and 9.2.5 of [1] ClockProfileType ::= INTEGER { default(1), telecom(2), vendorspecific(3) } -- TEXTUAL-CONVENTION -- Status -- mandatory -- Descr -- Clock Profile used. From [1] section 3.1.30, Profile is the set -- of allowed Precision Time Protocol (PTP) features applicable to -- a device. -- Refer -- Section 3.1.30 and 19.3 PTP profiles of [1] ClockQualityAccuracyType ::= INTEGER { reserved00(1), nanoSecond25(32), nanoSecond100(33), nanoSecond250(34), microSec1(35), microSec2dot5(36), microSec10(37), microSec25(38), microSec100(39), microSec250(40), milliSec1(41), milliSec2dot5(42), milliSec10(43), milliSec25(44), milliSec100(45), milliSec250(46), second1(47), second10(48), secondGreater10(49), unknown(254), reserved255(255) } -- TEXTUAL-CONVENTION -- Status -- mandatory -- Descr -- The ClockQuality as specified in section 5.3.7, 7.6.2.5 and -- Table 6 of [1]. -- -- The following values are not represented in the enumerated -- values. -- -- 0x01-0x1F Reserved -- 0x32-0x7F Reserved -- -- It is important to note that section 7.1.1 RFC2578 allows for -- gaps and enumerate values to start with zero when indicated by -- the protocol. -- Refer -- Section 5.3.7, 7.6.2.5 and Table 6 of [1] ClockQualityClassType ::= Gauge(0..255) -- TEXTUAL-CONVENTION -- DspHint -- d -- Status -- mandatory -- Descr -- The ClockQuality as specified in section 5.3.7, 7.6.2.4 and -- Table 5 of [1]. -- -- Value Description -- ====== -- ========================================================== -- 0 Reserved to enable compatibility with future -- versions. -- 1-5 Reserved -- 6 Shall designate a clock that is synchronized -- to a primary reference time source. The -- timescale distributed shall be PTP. A -- clockClass 6 clock shall not be a slave to -- another clock in the domain. -- 7 Shall designate a clock that has previously -- been designated as clockClass 6 but that has -- lost the ability to synchronize to a primary -- reference time source and is in holdover mode -- and within holdover specifications. The -- timescale distributed shall be PTP. A -- clockClass 7 clock shall not be a slave to -- another clock in the domain. -- 8 Reserved. -- 9-10 Reserved to enable compatibility with future -- versions. -- 11-12 Reserved. -- 13 Shall designate a clock that is synchronized -- to an application-specific source of time. -- The timescale distributed shall be ARB. A -- clockClass 13 clock shall not be a slave to -- another clock in the domain. -- 14 Shall designate a clock that has previously -- been designated as clockClass 13 but that -- has lost the ability to synchronize to an -- application-specific source of time and is -- in holdover mode and within holdover -- specifications. The timescale distributed -- shall be ARB. A clockClass 14 clock shall -- not be a slave to another clock in the domain. -- 15-51 Reserved. -- 52 Degradation alternative A for a clock of -- clockClass 7 that is not within holdover -- specification. A clock of clockClass 52 -- shall not be a slave to another clock in -- the domain. -- 53-57 Reserved. -- 58 Degradation alternative A for a clock of -- clockClass 14 that is not within holdover -- specification. A clock of clockClass 58 shall -- not be a slave to another clock in the domain. -- 59-67 Reserved. -- 68-122 For use by alternate PTP profiles. -- 123-127 Reserved. -- 128-132 Reserved. -- 133-170 For use by alternate PTP profiles. -- 171-186 Reserved. -- -- 187 Degradation alternative B for a clock of -- clockClass 7 that is not within holdover -- specification. A clock of clockClass 187 may -- be a slave to another clock in the domain. -- 188-192 Reserved. -- 193 Degradation alternative B for a clock of -- clockClass 14 that is not within holdover -- specification. A clock of clockClass 193 may -- be a slave to another clock in the domain. -- 194-215 Reserved. -- 216-232 For use by alternate PTP profiles. -- 233-247 Reserved. -- 248 Default. This clockClass shall be used if -- none of the other clockClass definitions apply. -- 249-250 Reserved. -- 251 Reserved for version 1 compatibility; see Clause 18. -- 252-254 Reserved. -- 255 Shall be the clockClass of a slave-only clock; see -- 9.2.2. -- Refer -- section 5.3.7, 7.6.2.4 and Table 5 of [1]. ClockRoleType ::= INTEGER { master(1), slave(2) } -- TEXTUAL-CONVENTION -- Status -- mandatory -- Descr -- The Clock Role. The protocol generates a Master Slave -- relationship among the clocks in the system. -- -- Clock Role Value Description -- ============================================================== -- Master clock 1 A clock that is the source of -- time to which all other clocks on -- that path synchronize. -- -- Slave clock 2 A clock which synchronizes to -- another clock (master). ClockStateType ::= INTEGER { freerun(1), holdover(2), acquiring(3), frequencyLocked(4), phaseAligned(5) } -- TEXTUAL-CONVENTION -- Status -- mandatory -- Descr -- The clock state returned by PTP engine. -- -- Clock State Value Description -- ============================================================== -- Freerun state 1 Applies to a slave device that is not -- locked to a master. This is the initial -- state a slave starts out with when it -- is not getting any PTP packets from the -- master or because of some other input -- error (erroneous packets, etc). -- -- Holdover state 2 In this state the slave device is -- locked to a master but communication -- with the master is lost or the -- timestamps in the ptp packets are -- incorrect. But since the slave was -- locked to the master, it can run with -- the same accuracy for sometime. The -- slave can continue to operate in this -- state for some time. If communication -- with the master is not restored for a -- while, the device is moved to the -- FREERUN state. -- -- Acquiring state 3 The slave device is receiving packets -- from a master and is trying to acquire -- a lock. -- -- Freq_locked state 4 Slave device is locked to the Master -- with respect to frequency, but not phase -- aligned -- -- Phase_aligned state 5 Locked to the master with respect to -- frequency and phase. ClockTimeSourceType ::= INTEGER { atomicClock(16), gps(32), terrestrialRadio(48), ptp(64), ntp(80), handSet(96), other(144), internalOsillator(160) } -- TEXTUAL-CONVENTION -- Status -- mandatory -- Descr -- The ClockQuality as specified in section 5.3.7, 7.6.2.6 and -- Table 7 of [1]. -- -- The following values are not represented in the enumerated -- values. -- -- 0xF0-0xFE For use by alternate PTP profiles -- 0xFF Reserved -- -- It is important to note that section 7.1.1 RFC2578 allows for -- gaps and enumerate values to start with zero when indicated by -- the protocol. -- Refer -- section 5.3.7, 7.6.2.6 and Table 7 of [1]. ClockTimeInterval ::= OCTET STRING(SIZE(1..255)) -- TEXTUAL-CONVENTION -- Status -- mandatory -- Descr -- This textual convention corresponds to the TimeInterval -- structure indicated in section 5.3.2 of [1]. It will be -- presented in the form of a character array. -- -- The TimeInterval type represents time intervals. -- -- struct TimeInterval -- { -- Integer64 scaledNanoseconds; -- }; -- -- The scaledNanoseconds member is the time interval expressed in -- units of nanoseconds and multiplied by 2**16. -- -- Positive or negative time intervals outside the maximum range -- of this data type shall be encoded as the largest positive and -- negative values of the data type, respectively. -- -- For example, 2.5 ns is expressed as 0000 0000 0002 8000 in -- Base16. -- Refer -- Section 5.3.2 and setion 7.7.2.1 Timer interval -- specification of [1] ClockTxModeType ::= INTEGER { unicast(1), multicast(2), multicastmix(3) } -- TEXTUAL-CONVENTION -- Status -- mandatory -- Descr -- Transmission mode. -- -- unicast. Using unicast commnuication channel. -- -- multicast. Using Multicast communication channel. -- -- multicast-mix. Using multicast-unicast communication channel ClockType ::= INTEGER { ordinaryClock(1), boundaryClock(2), transparentClock(3), boundaryNode(4) } -- TEXTUAL-CONVENTION -- Status -- mandatory -- Descr -- The clock types as defined in the MIB module description. -- Refer -- section 6.5.1 of [1]. cPtpSystemTable OBJECT-TYPE SYNTAX SEQUENCE OF CPtpSystemEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of count information about the PTP system for all domains." ::= { ciscoPtpMIBSystemInfo 1 } cPtpSystemEntry OBJECT-TYPE SYNTAX CPtpSystemEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the table, containing count information about a single domain. New row entries are added when the PTP clock for this domain is configured, while the unconfiguration of the PTP clock removes it." INDEX { cPtpDomainIndex, cPtpInstanceIndex } ::= { cPtpSystemTable 1 } CPtpSystemEntry ::= SEQUENCE { cPtpDomainIndex ClockDomainType, cPtpInstanceIndex ClockInstanceType, cPtpDomainClockPortsTotal Gauge, cPtpDomainClockPortPhysicalInterfacesTotal Gauge } cPtpDomainIndex OBJECT-TYPE SYNTAX ClockDomainType -- Rsyntax Gauge(0..255) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specifies the domain number used to create logical group of PTP devices. The Clock Domain is a logical group of clocks and devices that synchronize with each other using the PTP protocol. 0 Default domain 1 Alternate domain 1 2 Alternate domain 2 3 Alternate domain 3 4 - 127 User-defined domains 128 - 255 Reserved" ::= { cPtpSystemEntry 1 } cPtpInstanceIndex OBJECT-TYPE SYNTAX ClockInstanceType(0..255) -- Rsyntax Gauge(0..255) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specifies the instance of the Clock for this domain." ::= { cPtpSystemEntry 2 } cPtpDomainClockPortsTotal OBJECT-TYPE SYNTAX Gauge -- Units -- ptp ports ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the total number of clock ports configured within a domain." ::= { cPtpSystemEntry 3 } cPtpDomainClockPortPhysicalInterfacesTotal OBJECT-TYPE SYNTAX Gauge -- Units -- physical ports ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the total number of clock port Physical interfaces configured within a domain instance for PTP communications." ::= { cPtpSystemEntry 4 } cPtpSystemDomainTable OBJECT-TYPE SYNTAX SEQUENCE OF CPtpSystemDomainEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of information about the PTP system for all clock modes -- ordinary, boundary or transparent." ::= { ciscoPtpMIBSystemInfo 2 } cPtpSystemDomainEntry OBJECT-TYPE SYNTAX CPtpSystemDomainEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the table, containing information about a single clock mode for the PTP system. A row entry gets added when PTP clocks are configured on the router." INDEX { cPtpSystemDomainClockTypeIndex } ::= { cPtpSystemDomainTable 1 } CPtpSystemDomainEntry ::= SEQUENCE { cPtpSystemDomainClockTypeIndex ClockType, cPtpSystemDomainTotals Gauge } cPtpSystemDomainClockTypeIndex OBJECT-TYPE SYNTAX ClockType -- Rsyntax INTEGER { -- ordinaryClock(1), -- boundaryClock(2), -- transparentClock(3), -- boundaryNode(4) -- } ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specifies the clock type as defined in the Textual convention description." ::= { cPtpSystemDomainEntry 1 } cPtpSystemDomainTotals OBJECT-TYPE SYNTAX Gauge -- Units -- domains ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the total number of PTP domains for this particular clock type configured in this node." ::= { cPtpSystemDomainEntry 2 } cPtpClockNodeTable OBJECT-TYPE SYNTAX SEQUENCE OF CPtpClockNodeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of information about the PTP system for a given domain." ::= { ciscoPtpMIBSystemInfo 3 } cPtpClockNodeEntry OBJECT-TYPE SYNTAX CPtpClockNodeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the table, containing information about a single domain. A entry is added when a new PTP clock domain is configured on the router." INDEX { cPtpClockDomainIndex, cPtpClockTypeIndex, cPtpClockInstanceIndex } ::= { cPtpClockNodeTable 1 } CPtpClockNodeEntry ::= SEQUENCE { cPtpClockDomainIndex ClockDomainType, cPtpClockTypeIndex ClockType, cPtpClockInstanceIndex ClockInstanceType, cPtpClockInput1ppsEnabled TruthValue, cPtpClockInputFrequencyEnabled TruthValue, cPtpClockTODEnabled TruthValue, cPtpClockOutput1ppsEnabled TruthValue, cPtpClockOutput1ppsOffsetEnabled TruthValue, cPtpClockOutput1ppsOffsetValue Gauge, cPtpClockOutput1ppsOffsetNegative TruthValue, cPtpClockInput1ppsInterface DisplayString, cPtpClockOutput1ppsInterface DisplayString, cPtpClockTODInterface DisplayString } cPtpClockDomainIndex OBJECT-TYPE SYNTAX ClockDomainType -- Rsyntax Gauge(0..255) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specifies the domain number used to create logical group of PTP devices." ::= { cPtpClockNodeEntry 1 } cPtpClockTypeIndex OBJECT-TYPE SYNTAX ClockType -- Rsyntax INTEGER { -- ordinaryClock(1), -- boundaryClock(2), -- transparentClock(3), -- boundaryNode(4) -- } ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specifies the clock type as defined in the Textual convention description." ::= { cPtpClockNodeEntry 2 } cPtpClockInstanceIndex OBJECT-TYPE SYNTAX ClockInstanceType(0..255) -- Rsyntax Gauge(0..255) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specifies the instance of the Clock for this clock type for the given domain." ::= { cPtpClockNodeEntry 3 } cPtpClockInput1ppsEnabled OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies whether the node is enabled for PTP input clocking using the 1pps interface." ::= { cPtpClockNodeEntry 4 } cPtpClockInputFrequencyEnabled OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies whether enabled for Frequency input using the 1.544 Mhz, 2.048 Mhz, or 10Mhz timing interface." ::= { cPtpClockNodeEntry 5 } cPtpClockTODEnabled OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies whether the node is enabled for TOD." ::= { cPtpClockNodeEntry 6 } cPtpClockOutput1ppsEnabled OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies whether the node is enabled for PTP input clocking using the 1pps interface." ::= { cPtpClockNodeEntry 7 } cPtpClockOutput1ppsOffsetEnabled OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies whether an offset is configured in order to compensate for a known phase error such as network asymmetry." REFERENCE "section 11 Clock offset, path delay, residence time, and asymmetry corrections of [1]" ::= { cPtpClockNodeEntry 8 } cPtpClockOutput1ppsOffsetValue OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the fixed offset value configured to be added for the 1pps output." ::= { cPtpClockNodeEntry 9 } cPtpClockOutput1ppsOffsetNegative OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies whether the added (fixed) offset to the 1pps output is negative or not. When object returns TRUE the offset is negative and when object returns FALSE the offset is positive." ::= { cPtpClockNodeEntry 10 } cPtpClockInput1ppsInterface OBJECT-TYPE SYNTAX DisplayString -- Rsyntax OCTET STRING(SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the 1pps interface used for PTP input clocking." ::= { cPtpClockNodeEntry 11 } cPtpClockOutput1ppsInterface OBJECT-TYPE SYNTAX DisplayString -- Rsyntax OCTET STRING(SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the 1pps interface used for PTP output clocking." ::= { cPtpClockNodeEntry 12 } cPtpClockTODInterface OBJECT-TYPE SYNTAX DisplayString -- Rsyntax OCTET STRING(SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the interface used for PTP TOD." ::= { cPtpClockNodeEntry 13 } cPtpSystemProfile OBJECT-TYPE SYNTAX ClockProfileType -- Rsyntax INTEGER { -- default(1), -- telecom(2), -- vendorspecific(3) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the PTP Profile implemented on the system." REFERENCE "Section 19.3 PTP profiles of [1]" ::= { ciscoPtpMIBSystemInfo 4 } cPtpClockCurrentDSTable OBJECT-TYPE SYNTAX SEQUENCE OF CPtpClockCurrentDSEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of information about the PTP clock Current Datasets for all domains." ::= { ciscoPtpMIBClockInfo 1 } cPtpClockCurrentDSEntry OBJECT-TYPE SYNTAX CPtpClockCurrentDSEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the table, containing information about a single PTP clock Current Datasets for a domain." REFERENCE "1588 Version 2.0 Section 8.2.2 currentDS data set member specifications of [1]" INDEX { cPtpClockCurrentDSDomainIndex, cPtpClockCurrentDSClockTypeIndex, cPtpClockCurrentDSInstanceIndex } ::= { cPtpClockCurrentDSTable 1 } CPtpClockCurrentDSEntry ::= SEQUENCE { cPtpClockCurrentDSDomainIndex ClockDomainType, cPtpClockCurrentDSClockTypeIndex ClockType, cPtpClockCurrentDSInstanceIndex ClockInstanceType, cPtpClockCurrentDSStepsRemoved Counter, cPtpClockCurrentDSOffsetFromMaster ClockTimeInterval, cPtpClockCurrentDSMeanPathDelay ClockTimeInterval } cPtpClockCurrentDSDomainIndex OBJECT-TYPE SYNTAX ClockDomainType -- Rsyntax Gauge(0..255) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specifies the domain number used to create logical group of PTP devices." ::= { cPtpClockCurrentDSEntry 1 } cPtpClockCurrentDSClockTypeIndex OBJECT-TYPE SYNTAX ClockType -- Rsyntax INTEGER { -- ordinaryClock(1), -- boundaryClock(2), -- transparentClock(3), -- boundaryNode(4) -- } ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specifies the clock type as defined in the Textual convention description." ::= { cPtpClockCurrentDSEntry 2 } cPtpClockCurrentDSInstanceIndex OBJECT-TYPE SYNTAX ClockInstanceType(0..255) -- Rsyntax Gauge(0..255) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specifies the instance of the clock for this clock type in the given domain." ::= { cPtpClockCurrentDSEntry 3 } cPtpClockCurrentDSStepsRemoved OBJECT-TYPE SYNTAX Counter -- Units -- steps ACCESS read-only STATUS mandatory DESCRIPTION "The current clock dataset StepsRemoved value. This object specifies the distance measured by the number of Boundary clocks between the local clock and the Foreign master as indicated in the stepsRemoved field of Announce messages." REFERENCE "1588 Version 2.0 Section 8.2.2.2 stepsRemoved" ::= { cPtpClockCurrentDSEntry 4 } cPtpClockCurrentDSOffsetFromMaster OBJECT-TYPE SYNTAX ClockTimeInterval -- Rsyntax OCTET STRING(SIZE(1..255)) -- Units -- Time Interval ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the current clock dataset ClockOffset value. The value of the computation of the offset in time between a slave and a master clock." REFERENCE "1588 Version 2.0 Section 8.2.2.3 of [1]" ::= { cPtpClockCurrentDSEntry 5 } cPtpClockCurrentDSMeanPathDelay OBJECT-TYPE SYNTAX ClockTimeInterval -- Rsyntax OCTET STRING(SIZE(1..255)) ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the current clock dataset MeanPathDelay value. The mean path delay between a pair of ports as measure by the delay request-response mechanism." REFERENCE "1588 Version 2.0 Section 8.2.2.4 mean path delay" ::= { cPtpClockCurrentDSEntry 6 } cPtpClockParentDSTable OBJECT-TYPE SYNTAX SEQUENCE OF CPtpClockParentDSEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of information about the PTP clock Parent Datasets for all domains." ::= { ciscoPtpMIBClockInfo 2 } cPtpClockParentDSEntry OBJECT-TYPE SYNTAX CPtpClockParentDSEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the table, containing information about a single PTP clock Parent Datasets for a domain." REFERENCE "Section 8.2.3 parentDS data set member specifications of [1]" INDEX { cPtpClockParentDSDomainIndex, cPtpClockParentDSClockTypeIndex, cPtpClockParentDSInstanceIndex } ::= { cPtpClockParentDSTable 1 } CPtpClockParentDSEntry ::= SEQUENCE { cPtpClockParentDSDomainIndex ClockDomainType, cPtpClockParentDSClockTypeIndex ClockType, cPtpClockParentDSInstanceIndex ClockInstanceType, cPtpClockParentDSParentPortIdentity OCTET STRING, cPtpClockParentDSParentStats TruthValue, cPtpClockParentDSOffset ClockIntervalBase2, cPtpClockParentDSClockPhChRate INTEGER, cPtpClockParentDSGMClockIdentity ClockIdentity, cPtpClockParentDSGMClockPriority1 INTEGER, cPtpClockParentDSGMClockPriority2 INTEGER, cPtpClockParentDSGMClockQualityClass ClockQualityClassType, cPtpClockParentDSGMClockQualityAccuracy ClockQualityAccuracyType, cPtpClockParentDSGMClockQualityOffset Gauge } cPtpClockParentDSDomainIndex OBJECT-TYPE SYNTAX ClockDomainType -- Rsyntax Gauge(0..255) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specifies the domain number used to create logical group of PTP devices." ::= { cPtpClockParentDSEntry 1 } cPtpClockParentDSClockTypeIndex OBJECT-TYPE SYNTAX ClockType -- Rsyntax INTEGER { -- ordinaryClock(1), -- boundaryClock(2), -- transparentClock(3), -- boundaryNode(4) -- } ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specifies the clock type as defined in the Textual convention description." ::= { cPtpClockParentDSEntry 2 } cPtpClockParentDSInstanceIndex OBJECT-TYPE SYNTAX ClockInstanceType(0..255) -- Rsyntax Gauge(0..255) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specifies the instance of the clock for this clock type in the given domain." ::= { cPtpClockParentDSEntry 3 } cPtpClockParentDSParentPortIdentity OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the value of portIdentity of the port on the master that issues the Sync messages used in synchronizing this clock." REFERENCE "section 8.2.3.2 parentDS.parentPortIdentity of [1]" ::= { cPtpClockParentDSEntry 4 } cPtpClockParentDSParentStats OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the Parent Dataset ParentStats value. This value indicates whether the values of ParentDSOffset and ParentDSClockPhChRate have been measured and are valid. A TRUE value shall indicate valid data." REFERENCE "section 8.2.3.3 parentDS.parentStats of [1]" ::= { cPtpClockParentDSEntry 5 } cPtpClockParentDSOffset OBJECT-TYPE SYNTAX ClockIntervalBase2(-128..127) -- Rsyntax INTEGER(-128..127) ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the Parent Dataset ParentOffsetScaledLogVariance value. This value is the variance of the parent clocks phase as measured by the local clock." REFERENCE "section 8.2.3.4 parentDS.observedParentOffsetScaledLogVariance [1]" ::= { cPtpClockParentDSEntry 6 } cPtpClockParentDSClockPhChRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the clock's parent dataset ParentClockPhaseChangeRate value. This value is an estimate of the parent clocks phase change rate as measured by the slave clock." REFERENCE "section 8.2.3.5 parentDS.observedParentClockPhaseChangeRate of [1]" ::= { cPtpClockParentDSEntry 7 } cPtpClockParentDSGMClockIdentity OBJECT-TYPE SYNTAX ClockIdentity -- Rsyntax OCTET STRING(SIZE(1..255)) ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the parent dataset Grandmaster clock identity." REFERENCE "section 8.2.3.6 parentDS.grandmasterIdentity of [1]" ::= { cPtpClockParentDSEntry 8 } cPtpClockParentDSGMClockPriority1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the parent dataset Grandmaster clock priority1." REFERENCE "section 8.2.3.8 parentDS.grandmasterPriority1 of [1]" ::= { cPtpClockParentDSEntry 9 } cPtpClockParentDSGMClockPriority2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the parent dataset grandmaster clock priority2." REFERENCE "section 8.2.3.9 parentDS.grandmasterPriority2 of [1]" ::= { cPtpClockParentDSEntry 10 } cPtpClockParentDSGMClockQualityClass OBJECT-TYPE SYNTAX ClockQualityClassType(0..255) -- Rsyntax Gauge(0..255) ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the parent dataset grandmaster clock quality class." REFERENCE "section 8.2.3.7 parentDS.grandmasterClockQuality of [1]" ::= { cPtpClockParentDSEntry 11 } cPtpClockParentDSGMClockQualityAccuracy OBJECT-TYPE SYNTAX ClockQualityAccuracyType -- Rsyntax INTEGER { -- reserved00(1), -- nanoSecond25(32), -- nanoSecond100(33), -- nanoSecond250(34), -- microSec1(35), -- microSec2dot5(36), -- microSec10(37), -- microSec25(38), -- microSec100(39), -- microSec250(40), -- milliSec1(41), -- milliSec2dot5(42), -- milliSec10(43), -- milliSec25(44), -- milliSec100(45), -- milliSec250(46), -- second1(47), -- second10(48), -- secondGreater10(49), -- unknown(254), -- reserved255(255) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the parent dataset grandmaster clock quality accuracy." REFERENCE "section 8.2.3.7 parentDS.grandmasterClockQuality of [1]" ::= { cPtpClockParentDSEntry 12 } cPtpClockParentDSGMClockQualityOffset OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the parent dataset grandmaster clock quality offset." REFERENCE "section 8.2.3.7 parentDS.grandmasterClockQuality of [1]" ::= { cPtpClockParentDSEntry 13 } cPtpClockDefaultDSTable OBJECT-TYPE SYNTAX SEQUENCE OF CPtpClockDefaultDSEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of information about the PTP clock Default Datasets for all domains." ::= { ciscoPtpMIBClockInfo 3 } cPtpClockDefaultDSEntry OBJECT-TYPE SYNTAX CPtpClockDefaultDSEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the table, containing information about a single PTP clock Default Datasets for a domain." INDEX { cPtpClockDefaultDSDomainIndex, cPtpClockDefaultDSClockTypeIndex, cPtpClockDefaultDSInstanceIndex } ::= { cPtpClockDefaultDSTable 1 } CPtpClockDefaultDSEntry ::= SEQUENCE { cPtpClockDefaultDSDomainIndex ClockDomainType, cPtpClockDefaultDSClockTypeIndex ClockType, cPtpClockDefaultDSInstanceIndex ClockInstanceType, cPtpClockDefaultDSTwoStepFlag TruthValue, cPtpClockDefaultDSClockIdentity ClockIdentity, cPtpClockDefaultDSPriority1 INTEGER, cPtpClockDefaultDSPriority2 INTEGER, cPtpClockDefaultDSSlaveOnly TruthValue, cPtpClockDefaultDSQualityClass ClockQualityClassType, cPtpClockDefaultDSQualityAccuracy ClockQualityAccuracyType, cPtpClockDefaultDSQualityOffset INTEGER } cPtpClockDefaultDSDomainIndex OBJECT-TYPE SYNTAX ClockDomainType -- Rsyntax Gauge(0..255) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specifies the domain number used to create logical group of PTP devices." ::= { cPtpClockDefaultDSEntry 1 } cPtpClockDefaultDSClockTypeIndex OBJECT-TYPE SYNTAX ClockType -- Rsyntax INTEGER { -- ordinaryClock(1), -- boundaryClock(2), -- transparentClock(3), -- boundaryNode(4) -- } ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specifies the clock type as defined in the Textual convention description." ::= { cPtpClockDefaultDSEntry 2 } cPtpClockDefaultDSInstanceIndex OBJECT-TYPE SYNTAX ClockInstanceType(0..255) -- Rsyntax Gauge(0..255) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specifies the instance of the clock for this clock type in the given domain." ::= { cPtpClockDefaultDSEntry 3 } cPtpClockDefaultDSTwoStepFlag OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies whether the Two Step process is used." ::= { cPtpClockDefaultDSEntry 4 } cPtpClockDefaultDSClockIdentity OBJECT-TYPE SYNTAX ClockIdentity -- Rsyntax OCTET STRING(SIZE(1..255)) ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the default Datasets clock identity." ::= { cPtpClockDefaultDSEntry 5 } cPtpClockDefaultDSPriority1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the default Datasets clock Priority1." ::= { cPtpClockDefaultDSEntry 6 } cPtpClockDefaultDSPriority2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the default Datasets clock Priority2." ::= { cPtpClockDefaultDSEntry 7 } cPtpClockDefaultDSSlaveOnly OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-only STATUS mandatory DESCRIPTION "Whether the SlaveOnly flag is set." ::= { cPtpClockDefaultDSEntry 8 } cPtpClockDefaultDSQualityClass OBJECT-TYPE SYNTAX ClockQualityClassType(0..255) -- Rsyntax Gauge(0..255) ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the default dataset Quality Class." ::= { cPtpClockDefaultDSEntry 9 } cPtpClockDefaultDSQualityAccuracy OBJECT-TYPE SYNTAX ClockQualityAccuracyType -- Rsyntax INTEGER { -- reserved00(1), -- nanoSecond25(32), -- nanoSecond100(33), -- nanoSecond250(34), -- microSec1(35), -- microSec2dot5(36), -- microSec10(37), -- microSec25(38), -- microSec100(39), -- microSec250(40), -- milliSec1(41), -- milliSec2dot5(42), -- milliSec10(43), -- milliSec25(44), -- milliSec100(45), -- milliSec250(46), -- second1(47), -- second10(48), -- secondGreater10(49), -- unknown(254), -- reserved255(255) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the default dataset Quality Accurarcy." ::= { cPtpClockDefaultDSEntry 10 } cPtpClockDefaultDSQualityOffset OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the default dataset Quality offset." ::= { cPtpClockDefaultDSEntry 11 } cPtpClockRunningTable OBJECT-TYPE SYNTAX SEQUENCE OF CPtpClockRunningEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of information about the PTP clock Running Datasets for all domains." ::= { ciscoPtpMIBClockInfo 4 } cPtpClockRunningEntry OBJECT-TYPE SYNTAX CPtpClockRunningEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the table, containing information about a single PTP clock running Datasets for a domain." INDEX { cPtpClockRunningDomainIndex, cPtpClockRunningClockTypeIndex, cPtpClockRunningInstanceIndex } ::= { cPtpClockRunningTable 1 } CPtpClockRunningEntry ::= SEQUENCE { cPtpClockRunningDomainIndex ClockDomainType, cPtpClockRunningClockTypeIndex ClockType, cPtpClockRunningInstanceIndex ClockInstanceType, cPtpClockRunningState ClockStateType, cPtpClockRunningPacketsSent Counter, cPtpClockRunningPacketsReceived Counter } cPtpClockRunningDomainIndex OBJECT-TYPE SYNTAX ClockDomainType -- Rsyntax Gauge(0..255) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specifies the domain number used to create logical group of PTP devices." ::= { cPtpClockRunningEntry 1 } cPtpClockRunningClockTypeIndex OBJECT-TYPE SYNTAX ClockType -- Rsyntax INTEGER { -- ordinaryClock(1), -- boundaryClock(2), -- transparentClock(3), -- boundaryNode(4) -- } ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specifies the clock type as defined in the Textual convention description." ::= { cPtpClockRunningEntry 2 } cPtpClockRunningInstanceIndex OBJECT-TYPE SYNTAX ClockInstanceType(0..255) -- Rsyntax Gauge(0..255) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specifies the instance of the clock for this clock type in the given domain." ::= { cPtpClockRunningEntry 3 } cPtpClockRunningState OBJECT-TYPE SYNTAX ClockStateType -- Rsyntax INTEGER { -- freerun(1), -- holdover(2), -- acquiring(3), -- frequencyLocked(4), -- phaseAligned(5) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the Clock state returned by PTP engine which was described earlier. Freerun state. Applies to a slave device that is not locked to a master. This is the initial state a slave starts out with when it is not getting any PTP packets from the master or because of some other input error (erroneous packets, etc). Holdover state. In this state the slave device is locked to a master but communication with the master is lost or the timestamps in the ptp packets are incorrect. But since the slave was locked to the master, it can run with the same accuracy for sometime. The slave can continue to operate in this state for some time. If communication with the master is not restored for a while, the device is moved to the FREERUN state. Acquiring state. The slave device is receiving packets from a master and is trying to acquire a lock. Freq_locked state. Slave device is locked to the Master with respect to frequency, but not phase aligned Phase_aligned state. Locked to the master with respect to frequency and phase." ::= { cPtpClockRunningEntry 4 } cPtpClockRunningPacketsSent OBJECT-TYPE SYNTAX --?? syntax is not convertable to SMIv1 Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the total number of all packet Unicast and multicast that have been sent out for this clock in this domain for this type." ::= { cPtpClockRunningEntry 5 } cPtpClockRunningPacketsReceived OBJECT-TYPE SYNTAX --?? syntax is not convertable to SMIv1 Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the total number of all packet Unicast and multicast that have been received for this clock in this domain for this type." ::= { cPtpClockRunningEntry 6 } cPtpClockTimePropertiesDSTable OBJECT-TYPE SYNTAX SEQUENCE OF CPtpClockTimePropertiesDSEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of information about the PTP clock Timeproperties Datasets for all domains." ::= { ciscoPtpMIBClockInfo 5 } cPtpClockTimePropertiesDSEntry OBJECT-TYPE SYNTAX CPtpClockTimePropertiesDSEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the table, containing information about a single PTP clock timeproperties Datasets for a domain." REFERENCE "Section 8.2.4 of [1]" INDEX { cPtpClockTimePropertiesDSDomainIndex, cPtpClockTimePropertiesDSClockTypeIndex, cPtpClockTimePropertiesDSInstanceIndex } ::= { cPtpClockTimePropertiesDSTable 1 } CPtpClockTimePropertiesDSEntry ::= SEQUENCE { cPtpClockTimePropertiesDSDomainIndex ClockDomainType, cPtpClockTimePropertiesDSClockTypeIndex ClockType, cPtpClockTimePropertiesDSInstanceIndex ClockInstanceType, cPtpClockTimePropertiesDSCurrentUTCOffsetValid TruthValue, cPtpClockTimePropertiesDSCurrentUTCOffset INTEGER, cPtpClockTimePropertiesDSLeap59 TruthValue, cPtpClockTimePropertiesDSLeap61 TruthValue, cPtpClockTimePropertiesDSTimeTraceable TruthValue, cPtpClockTimePropertiesDSFreqTraceable TruthValue, cPtpClockTimePropertiesDSPTPTimescale TruthValue, cPtpClockTimePropertiesDSSource ClockTimeSourceType } cPtpClockTimePropertiesDSDomainIndex OBJECT-TYPE SYNTAX ClockDomainType -- Rsyntax Gauge(0..255) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specifies the domain number used to create logical group of PTP devices." ::= { cPtpClockTimePropertiesDSEntry 1 } cPtpClockTimePropertiesDSClockTypeIndex OBJECT-TYPE SYNTAX ClockType -- Rsyntax INTEGER { -- ordinaryClock(1), -- boundaryClock(2), -- transparentClock(3), -- boundaryNode(4) -- } ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specifies the clock type as defined in the Textual convention description." ::= { cPtpClockTimePropertiesDSEntry 2 } cPtpClockTimePropertiesDSInstanceIndex OBJECT-TYPE SYNTAX ClockInstanceType(0..255) -- Rsyntax Gauge(0..255) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specifies the instance of the clock for this clock type in the given domain." ::= { cPtpClockTimePropertiesDSEntry 3 } cPtpClockTimePropertiesDSCurrentUTCOffsetValid OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the timeproperties dataset value of whether current UTC offset is valid." REFERENCE "Section 8.2.4.2 of [1]" ::= { cPtpClockTimePropertiesDSEntry 4 } cPtpClockTimePropertiesDSCurrentUTCOffset OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the timeproperties dataset value of current UTC offset. In PTP systems whose epoch is the PTP epoch, the value of timePropertiesDS.currentUtcOffset is the offset between TAI and UTC; otherwise the value has no meaning. The value shall be in units of seconds. The initialization value shall be selected as follows: a) If the timePropertiesDS.ptpTimescale (see 8.2.4.8) is TRUE, the value is the value obtained from a primary reference if the value is known at the time of initialization, else. b) The value shall be the current number of leap seconds (7.2.3) when the node is designed." REFERENCE "Section 8.2.4.3 of [1]" ::= { cPtpClockTimePropertiesDSEntry 5 } cPtpClockTimePropertiesDSLeap59 OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the Leap59 value in the clock Current Dataset." REFERENCE "Section 8.2.4.4 of [1]" ::= { cPtpClockTimePropertiesDSEntry 6 } cPtpClockTimePropertiesDSLeap61 OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the Leap61 value in the clock Current Dataset." REFERENCE "Section 8.2.4.5 of [1]" ::= { cPtpClockTimePropertiesDSEntry 7 } cPtpClockTimePropertiesDSTimeTraceable OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the Timetraceable value in the clock Current Dataset." REFERENCE "Section 8.2.4.6 of [1]" ::= { cPtpClockTimePropertiesDSEntry 8 } cPtpClockTimePropertiesDSFreqTraceable OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the Frequency Traceable value in the clock Current Dataset." REFERENCE "Section 8.2.4.7 of [1]" ::= { cPtpClockTimePropertiesDSEntry 9 } cPtpClockTimePropertiesDSPTPTimescale OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the PTP Timescale value in the clock Current Dataset." REFERENCE "Section 8.2.4.8 of [1]" ::= { cPtpClockTimePropertiesDSEntry 10 } cPtpClockTimePropertiesDSSource OBJECT-TYPE SYNTAX ClockTimeSourceType -- Rsyntax INTEGER { -- atomicClock(16), -- gps(32), -- terrestrialRadio(48), -- ptp(64), -- ntp(80), -- handSet(96), -- other(144), -- internalOsillator(160) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the Timesource value in the clock Current Dataset." REFERENCE "Section 8.2.4.9 of [1]" ::= { cPtpClockTimePropertiesDSEntry 11 } cPtpClockTransDefaultDSTable OBJECT-TYPE SYNTAX SEQUENCE OF CPtpClockTransDefaultDSEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of information about the PTP Transparent clock Default Datasets for all domains." ::= { ciscoPtpMIBClockInfo 6 } cPtpClockTransDefaultDSEntry OBJECT-TYPE SYNTAX CPtpClockTransDefaultDSEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the table, containing information about a single PTP Transparent clock Default Datasets for a domain." REFERENCE "Section 8.3.2 of [1]" INDEX { cPtpClockTransDefaultDSDomainIndex, cPtpClockTransDefaultDSInstanceIndex } ::= { cPtpClockTransDefaultDSTable 1 } CPtpClockTransDefaultDSEntry ::= SEQUENCE { cPtpClockTransDefaultDSDomainIndex ClockDomainType, cPtpClockTransDefaultDSInstanceIndex ClockInstanceType, cPtpClockTransDefaultDSClockIdentity ClockIdentity, cPtpClockTransDefaultDSNumOfPorts Counter, cPtpClockTransDefaultDSDelay ClockMechanismType, cPtpClockTransDefaultDSPrimaryDomain INTEGER } cPtpClockTransDefaultDSDomainIndex OBJECT-TYPE SYNTAX ClockDomainType -- Rsyntax Gauge(0..255) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specifies the domain number used to create logical group of PTP devices." ::= { cPtpClockTransDefaultDSEntry 1 } cPtpClockTransDefaultDSInstanceIndex OBJECT-TYPE SYNTAX ClockInstanceType(0..255) -- Rsyntax Gauge(0..255) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specifies the instance of the clock for this clock type in the given domain." ::= { cPtpClockTransDefaultDSEntry 2 } cPtpClockTransDefaultDSClockIdentity OBJECT-TYPE SYNTAX ClockIdentity -- Rsyntax OCTET STRING(SIZE(1..255)) ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the value of the clockIdentity attribute of the local clock." REFERENCE "Section 8.3.2.2.1 of [1]" ::= { cPtpClockTransDefaultDSEntry 3 } cPtpClockTransDefaultDSNumOfPorts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the number of PTP ports of the device." REFERENCE "Section 8.3.2.2.2 of [1]" ::= { cPtpClockTransDefaultDSEntry 4 } cPtpClockTransDefaultDSDelay OBJECT-TYPE SYNTAX ClockMechanismType -- Rsyntax INTEGER { -- e2e(1), -- p2p(2), -- disabled(254) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This object, if the transparent clock is an end-to-end transparent clock, has the value shall be E2E; If the transparent clock is a peer-to-peer transparent clock, the value shall be P2P." REFERENCE "Section 8.3.2.3.1 of [1]" ::= { cPtpClockTransDefaultDSEntry 5 } cPtpClockTransDefaultDSPrimaryDomain OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the value of the primary syntonization domain. The initialization value shall be 0." REFERENCE "Section 8.3.2.3.2 of [1]" ::= { cPtpClockTransDefaultDSEntry 6 } cPtpClockPortTable OBJECT-TYPE SYNTAX SEQUENCE OF CPtpClockPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of information about the clock ports for a particular domain." ::= { ciscoPtpMIBClockInfo 7 } cPtpClockPortEntry OBJECT-TYPE SYNTAX CPtpClockPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the table, containing information about a single clock port." INDEX { cPtpClockPortDomainIndex, cPtpClockPortClockTypeIndex, cPtpClockPortClockInstanceIndex, cPtpClockPortTablePortNumberIndex } ::= { cPtpClockPortTable 1 } CPtpClockPortEntry ::= SEQUENCE { cPtpClockPortDomainIndex ClockDomainType, cPtpClockPortClockTypeIndex ClockType, cPtpClockPortClockInstanceIndex ClockInstanceType, cPtpClockPortTablePortNumberIndex ClockPortNumber, cPtpClockPortName DisplayString, cPtpClockPortRole ClockRoleType, cPtpClockPortSyncOneStep TruthValue, cPtpClockPortCurrentPeerAddressType InetAddressType, cPtpClockPortCurrentPeerAddress InetAddress, cPtpClockPortNumOfAssociatedPorts Gauge } cPtpClockPortDomainIndex OBJECT-TYPE SYNTAX ClockDomainType -- Rsyntax Gauge(0..255) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specifies the domain number used to create logical group of PTP devices." ::= { cPtpClockPortEntry 1 } cPtpClockPortClockTypeIndex OBJECT-TYPE SYNTAX ClockType -- Rsyntax INTEGER { -- ordinaryClock(1), -- boundaryClock(2), -- transparentClock(3), -- boundaryNode(4) -- } ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specifies the clock type as defined in the Textual convention description." ::= { cPtpClockPortEntry 2 } cPtpClockPortClockInstanceIndex OBJECT-TYPE SYNTAX ClockInstanceType(0..255) -- Rsyntax Gauge(0..255) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specifies the instance of the clock for this clock type in the given domain." ::= { cPtpClockPortEntry 3 } cPtpClockPortTablePortNumberIndex OBJECT-TYPE SYNTAX ClockPortNumber(1..65535) -- Rsyntax Gauge(1..65535) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specifies the PTP Portnumber for this port." ::= { cPtpClockPortEntry 4 } cPtpClockPortName OBJECT-TYPE SYNTAX DisplayString(SIZE(1..64)) -- Rsyntax OCTET STRING(SIZE(1..64)) ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the PTP clock port name configured on the router." ::= { cPtpClockPortEntry 5 } cPtpClockPortRole OBJECT-TYPE SYNTAX ClockRoleType -- Rsyntax INTEGER { -- master(1), -- slave(2) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This object describes the current role (slave/master) of the port." ::= { cPtpClockPortEntry 6 } cPtpClockPortSyncOneStep OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies that one-step clock operation between the PTP master and slave device is enabled." ::= { cPtpClockPortEntry 7 } cPtpClockPortCurrentPeerAddressType OBJECT-TYPE SYNTAX InetAddressType -- Rsyntax INTEGER { -- ?? enum value of zero may cause problems -- unknown(0), -- ipv4(1), -- ipv6(2), -- ipv4z(3), -- ipv6z(4), -- dns(16) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the current peer's network address used for PTP communication. Based on the scenario and the setup involved, the values might look like these - Scenario Value ------------------- ---------------- Single Master master port Multiple Masters selected master port Single Slave slave port Multiple Slaves (In relevant setups, information on available slaves and available masters will be available through cPtpClockPortAssociateTable)" ::= { cPtpClockPortEntry 8 } cPtpClockPortCurrentPeerAddress OBJECT-TYPE SYNTAX InetAddress -- Rsyntax OCTET STRING(SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the current peer's network address used for PTP communication. Based on the scenario and the setup involved, the values might look like these - Scenario Value ------------------- ---------------- Single Master master port Multiple Masters selected master port Single Slave slave port Multiple Slaves (In relevant setups, information on available slaves and available masters will be available through cPtpClockPortAssociateTable)" ::= { cPtpClockPortEntry 9 } cPtpClockPortNumOfAssociatedPorts OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies - For a master port - the number of PTP slave sessions (peers) associated with this PTP port. For a slave port - the number of masters available to this slave port (might or might not be peered)." ::= { cPtpClockPortEntry 10 } cPtpClockPortDSTable OBJECT-TYPE SYNTAX SEQUENCE OF CPtpClockPortDSEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of information about the clock ports dataset for a particular domain." ::= { ciscoPtpMIBClockInfo 8 } cPtpClockPortDSEntry OBJECT-TYPE SYNTAX CPtpClockPortDSEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the table, containing port dataset information for a single clock port." INDEX { cPtpClockPortDSDomainIndex, cPtpClockPortDSClockTypeIndex, cPtpClockPortDSClockInstanceIndex, cPtpClockPortDSPortNumberIndex } ::= { cPtpClockPortDSTable 1 } CPtpClockPortDSEntry ::= SEQUENCE { cPtpClockPortDSDomainIndex ClockDomainType, cPtpClockPortDSClockTypeIndex ClockType, cPtpClockPortDSClockInstanceIndex ClockInstanceType, cPtpClockPortDSPortNumberIndex ClockPortNumber, cPtpClockPortDSName DisplayString, cPtpClockPortDSPortIdentity OCTET STRING, cPtpClockPortDSAnnouncementInterval INTEGER, cPtpClockPortDSAnnounceRctTimeout INTEGER, cPtpClockPortDSSyncInterval INTEGER, cPtpClockPortDSMinDelayReqInterval INTEGER, cPtpClockPortDSPeerDelayReqInterval INTEGER, cPtpClockPortDSDelayMech ClockMechanismType, cPtpClockPortDSPeerMeanPathDelay ClockTimeInterval, cPtpClockPortDSGrantDuration Gauge, cPtpClockPortDSPTPVersion INTEGER } cPtpClockPortDSDomainIndex OBJECT-TYPE SYNTAX ClockDomainType -- Rsyntax Gauge(0..255) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specifies the domain number used to create logical group of PTP devices." ::= { cPtpClockPortDSEntry 1 } cPtpClockPortDSClockTypeIndex OBJECT-TYPE SYNTAX ClockType -- Rsyntax INTEGER { -- ordinaryClock(1), -- boundaryClock(2), -- transparentClock(3), -- boundaryNode(4) -- } ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specifies the clock type as defined in the Textual convention description." ::= { cPtpClockPortDSEntry 2 } cPtpClockPortDSClockInstanceIndex OBJECT-TYPE SYNTAX ClockInstanceType(0..255) -- Rsyntax Gauge(0..255) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specifies the instance of the clock for this clock type in the given domain." ::= { cPtpClockPortDSEntry 3 } cPtpClockPortDSPortNumberIndex OBJECT-TYPE SYNTAX ClockPortNumber(1..65535) -- Rsyntax Gauge(1..65535) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specifies the PTP portnumber associated with this PTP port." ::= { cPtpClockPortDSEntry 4 } cPtpClockPortDSName OBJECT-TYPE SYNTAX DisplayString(SIZE(1..64)) -- Rsyntax OCTET STRING(SIZE(1..64)) ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the PTP clock port name." ::= { cPtpClockPortDSEntry 5 } cPtpClockPortDSPortIdentity OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the PTP clock port Identity." ::= { cPtpClockPortDSEntry 6 } cPtpClockPortDSAnnouncementInterval OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the Announce message transmission interval associated with this clock port." ::= { cPtpClockPortDSEntry 7 } cPtpClockPortDSAnnounceRctTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the Announce receipt timeout associated with this clock port." ::= { cPtpClockPortDSEntry 8 } cPtpClockPortDSSyncInterval OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the Sync message transmission interval." ::= { cPtpClockPortDSEntry 9 } cPtpClockPortDSMinDelayReqInterval OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the Delay_Req message transmission interval." ::= { cPtpClockPortDSEntry 10 } cPtpClockPortDSPeerDelayReqInterval OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the Pdelay_Req message transmission interval." ::= { cPtpClockPortDSEntry 11 } cPtpClockPortDSDelayMech OBJECT-TYPE SYNTAX ClockMechanismType -- Rsyntax INTEGER { -- e2e(1), -- p2p(2), -- disabled(254) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the delay mechanism used. If the clock is an end-to-end clock, the value of the is e2e, else if the clock is a peer to-peer clock, the value shall be p2p." ::= { cPtpClockPortDSEntry 12 } cPtpClockPortDSPeerMeanPathDelay OBJECT-TYPE SYNTAX ClockTimeInterval -- Rsyntax OCTET STRING(SIZE(1..255)) ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the peer meanPathDelay." ::= { cPtpClockPortDSEntry 13 } cPtpClockPortDSGrantDuration OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the grant duration allocated by the master." ::= { cPtpClockPortDSEntry 14 } cPtpClockPortDSPTPVersion OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the PTP version being used." ::= { cPtpClockPortDSEntry 15 } cPtpClockPortRunningTable OBJECT-TYPE SYNTAX SEQUENCE OF CPtpClockPortRunningEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of information about the clock ports running dataset for a particular domain." ::= { ciscoPtpMIBClockInfo 9 } cPtpClockPortRunningEntry OBJECT-TYPE SYNTAX CPtpClockPortRunningEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the table, containing runing dataset information about a single clock port." INDEX { cPtpClockPortRunningDomainIndex, cPtpClockPortRunningClockTypeIndex, cPtpClockPortRunningClockInstanceIndex, cPtpClockPortRunningPortNumberIndex } ::= { cPtpClockPortRunningTable 1 } CPtpClockPortRunningEntry ::= SEQUENCE { cPtpClockPortRunningDomainIndex ClockDomainType, cPtpClockPortRunningClockTypeIndex ClockType, cPtpClockPortRunningClockInstanceIndex ClockInstanceType, cPtpClockPortRunningPortNumberIndex ClockPortNumber, cPtpClockPortRunningName DisplayString, cPtpClockPortRunningState ClockPortState, cPtpClockPortRunningRole ClockRoleType, cPtpClockPortRunningInterfaceIndex InterfaceIndexOrZero, cPtpClockPortRunningIPversion INTEGER, cPtpClockPortRunningEncapsulationType INTEGER, cPtpClockPortRunningTxMode ClockTxModeType, cPtpClockPortRunningRxMode ClockTxModeType, cPtpClockPortRunningPacketsReceived Counter, cPtpClockPortRunningPacketsSent Counter } cPtpClockPortRunningDomainIndex OBJECT-TYPE SYNTAX ClockDomainType -- Rsyntax Gauge(0..255) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specifies the domain number used to create logical group of PTP devices." ::= { cPtpClockPortRunningEntry 1 } cPtpClockPortRunningClockTypeIndex OBJECT-TYPE SYNTAX ClockType -- Rsyntax INTEGER { -- ordinaryClock(1), -- boundaryClock(2), -- transparentClock(3), -- boundaryNode(4) -- } ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specifies the clock type as defined in the Textual convention description." ::= { cPtpClockPortRunningEntry 2 } cPtpClockPortRunningClockInstanceIndex OBJECT-TYPE SYNTAX ClockInstanceType(0..255) -- Rsyntax Gauge(0..255) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specifies the instance of the clock for this clock type in the given domain." ::= { cPtpClockPortRunningEntry 3 } cPtpClockPortRunningPortNumberIndex OBJECT-TYPE SYNTAX ClockPortNumber(1..65535) -- Rsyntax Gauge(1..65535) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specifies the PTP portnumber associated with this clock port." ::= { cPtpClockPortRunningEntry 4 } cPtpClockPortRunningName OBJECT-TYPE SYNTAX DisplayString(SIZE(1..64)) -- Rsyntax OCTET STRING(SIZE(1..64)) ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the PTP clock port name." ::= { cPtpClockPortRunningEntry 5 } cPtpClockPortRunningState OBJECT-TYPE SYNTAX ClockPortState -- Rsyntax INTEGER { -- initializing(1), -- faulty(2), -- disabled(3), -- listening(4), -- preMaster(5), -- master(6), -- passive(7), -- uncalibrated(8), -- slave(9) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the port state returned by PTP engine. initializing - In this state a port initializes its data sets, hardware, and communication facilities. faulty - The fault state of the protocol. disabled - The port shall not place any messages on its communication path. listening - The port is waiting for the announceReceiptTimeout to expire or to receive an Announce message from a master. preMaster - The port shall behave in all respects as though it were in the MASTER state except that it shall not place any messages on its communication path except for Pdelay_Req, Pdelay_Resp, Pdelay_Resp_Follow_Up, signaling, or management messages. master - The port is behaving as a master port. passive - The port shall not place any messages on its communication path except for Pdelay_Req, Pdelay_Resp, Pdelay_Resp_Follow_Up, or signaling messages, or management messages that are a required response to another management message uncalibrated - The local port is preparing to synchronize to the master port. slave - The port is synchronizing to the selected master port." ::= { cPtpClockPortRunningEntry 6 } cPtpClockPortRunningRole OBJECT-TYPE SYNTAX ClockRoleType -- Rsyntax INTEGER { -- master(1), -- slave(2) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the Clock Role." ::= { cPtpClockPortRunningEntry 7 } cPtpClockPortRunningInterfaceIndex OBJECT-TYPE SYNTAX InterfaceIndexOrZero -- Rsyntax INTEGER(0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the interface on the router being used by the PTP Clock for PTP communication." ::= { cPtpClockPortRunningEntry 8 } cPtpClockPortRunningIPversion OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object specifirst the IP version being used for PTP communication (the mapping used)." ::= { cPtpClockPortRunningEntry 9 } cPtpClockPortRunningEncapsulationType OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the type of encapsulation if the interface is adding extra layers (eg. VLAN, Pseudowire encapsulation...) for the PTP messages." ::= { cPtpClockPortRunningEntry 10 } cPtpClockPortRunningTxMode OBJECT-TYPE SYNTAX ClockTxModeType -- Rsyntax INTEGER { -- unicast(1), -- multicast(2), -- multicastmix(3) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the clock transmission mode as unicast: Using unicast commnuication channel. multicast: Using Multicast communication channel. multicast-mix: Using multicast-unicast communication channel" ::= { cPtpClockPortRunningEntry 11 } cPtpClockPortRunningRxMode OBJECT-TYPE SYNTAX ClockTxModeType -- Rsyntax INTEGER { -- unicast(1), -- multicast(2), -- multicastmix(3) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This object specifie the clock receive mode as unicast: Using unicast commnuication channel. multicast: Using Multicast communication channel. multicast-mix: Using multicast-unicast communication channel" ::= { cPtpClockPortRunningEntry 12 } cPtpClockPortRunningPacketsReceived OBJECT-TYPE SYNTAX --?? syntax is not convertable to SMIv1 Counter -- Units -- packets ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the packets received on the clock port (cummulative)." ::= { cPtpClockPortRunningEntry 13 } cPtpClockPortRunningPacketsSent OBJECT-TYPE SYNTAX --?? syntax is not convertable to SMIv1 Counter -- Units -- packets ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the packets sent on the clock port (cummulative)." ::= { cPtpClockPortRunningEntry 14 } cPtpClockPortTransDSTable OBJECT-TYPE SYNTAX SEQUENCE OF CPtpClockPortTransDSEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of information about the Transparent clock ports running dataset for a particular domain." ::= { ciscoPtpMIBClockInfo 10 } cPtpClockPortTransDSEntry OBJECT-TYPE SYNTAX CPtpClockPortTransDSEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the table, containing clock port Transparent dataset information about a single clock port" INDEX { cPtpClockPortTransDSDomainIndex, cPtpClockPortTransDSInstanceIndex, cPtpClockPortTransDSPortNumberIndex } ::= { cPtpClockPortTransDSTable 1 } CPtpClockPortTransDSEntry ::= SEQUENCE { cPtpClockPortTransDSDomainIndex ClockDomainType, cPtpClockPortTransDSInstanceIndex ClockInstanceType, cPtpClockPortTransDSPortNumberIndex ClockPortNumber, cPtpClockPortTransDSPortIdentity ClockIdentity, cPtpClockPortTransDSlogMinPdelayReqInt INTEGER, cPtpClockPortTransDSFaultyFlag TruthValue, cPtpClockPortTransDSPeerMeanPathDelay ClockTimeInterval } cPtpClockPortTransDSDomainIndex OBJECT-TYPE SYNTAX ClockDomainType -- Rsyntax Gauge(0..255) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specifies the domain number used to create logical group of PTP devices." ::= { cPtpClockPortTransDSEntry 1 } cPtpClockPortTransDSInstanceIndex OBJECT-TYPE SYNTAX ClockInstanceType(0..255) -- Rsyntax Gauge(0..255) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specifies the instance of the clock for this clock type in the given domain." ::= { cPtpClockPortTransDSEntry 2 } cPtpClockPortTransDSPortNumberIndex OBJECT-TYPE SYNTAX ClockPortNumber(1..65535) -- Rsyntax Gauge(1..65535) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specifies the PTP port number associated with this port." REFERENCE "Section 7.5.2 Port Identity of [1]" ::= { cPtpClockPortTransDSEntry 3 } cPtpClockPortTransDSPortIdentity OBJECT-TYPE SYNTAX ClockIdentity -- Rsyntax OCTET STRING(SIZE(1..255)) ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the value of the PortIdentity attribute of the local port." REFERENCE "Section 8.3.3.2.1 of [1]" ::= { cPtpClockPortTransDSEntry 4 } cPtpClockPortTransDSlogMinPdelayReqInt OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the value of the logarithm to the base 2 of the minPdelayReqInterval." REFERENCE "Section 8.3.3.3.1 of [1]" ::= { cPtpClockPortTransDSEntry 5 } cPtpClockPortTransDSFaultyFlag OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the value TRUE if the port is faulty and FALSE if the port is operating normally." REFERENCE "Section 8.3.3.3.2 of [1]" ::= { cPtpClockPortTransDSEntry 6 } cPtpClockPortTransDSPeerMeanPathDelay OBJECT-TYPE SYNTAX ClockTimeInterval -- Rsyntax OCTET STRING(SIZE(1..255)) ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies, (if the delayMechanism used is P2P) the value is the estimate of the current one-way propagation delay, i.e., on the link attached to this port computed using the peer delay mechanism. If the value of the delayMechanism used is E2E, then the value will be zero." REFERENCE "Section 8.3.3.3.3 of [1]" ::= { cPtpClockPortTransDSEntry 7 } cPtpClockPortAssociateTable OBJECT-TYPE SYNTAX SEQUENCE OF CPtpClockPortAssociateEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of information about a given port's associated ports. For a master port - multiple slave ports which have established sessions with the current master port. For a slave port - the list of masters available for a given slave port. Session information (pkts, errors) to be displayed based on availability and scenario." ::= { ciscoPtpMIBClockInfo 11 } cPtpClockPortAssociateEntry OBJECT-TYPE SYNTAX CPtpClockPortAssociateEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the table, containing information about a single associated port for the given clockport." INDEX { cPtpClockPortCurrentDomainIndex, cPtpClockPortCurrentClockTypeIndex, cPtpClockPortCurrentClockInstanceIndex, cPtpClockPortCurrentPortNumberIndex, cPtpClockPortAssociatePortIndex } ::= { cPtpClockPortAssociateTable 1 } CPtpClockPortAssociateEntry ::= SEQUENCE { cPtpClockPortCurrentDomainIndex ClockDomainType, cPtpClockPortCurrentClockTypeIndex ClockType, cPtpClockPortCurrentClockInstanceIndex ClockInstanceType, cPtpClockPortCurrentPortNumberIndex ClockPortNumber, cPtpClockPortAssociatePortIndex Gauge, cPtpClockPortAssociateAddressType InetAddressType, cPtpClockPortAssociateAddress InetAddress, cPtpClockPortAssociatePacketsSent Counter, cPtpClockPortAssociatePacketsReceived Counter, cPtpClockPortAssociateInErrors Counter, cPtpClockPortAssociateOutErrors Counter } cPtpClockPortCurrentDomainIndex OBJECT-TYPE SYNTAX ClockDomainType -- Rsyntax Gauge(0..255) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specifies the given port's domain number." ::= { cPtpClockPortAssociateEntry 1 } cPtpClockPortCurrentClockTypeIndex OBJECT-TYPE SYNTAX ClockType -- Rsyntax INTEGER { -- ordinaryClock(1), -- boundaryClock(2), -- transparentClock(3), -- boundaryNode(4) -- } ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specifies the given port's clock type." ::= { cPtpClockPortAssociateEntry 2 } cPtpClockPortCurrentClockInstanceIndex OBJECT-TYPE SYNTAX ClockInstanceType -- Rsyntax Gauge(0..255) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specifies the instance of the clock for this clock type in the given domain." ::= { cPtpClockPortAssociateEntry 3 } cPtpClockPortCurrentPortNumberIndex OBJECT-TYPE SYNTAX ClockPortNumber -- Rsyntax Gauge(0..65535) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specifies the PTP Port Number for the given port." ::= { cPtpClockPortAssociateEntry 4 } cPtpClockPortAssociatePortIndex OBJECT-TYPE SYNTAX Gauge(1..65535) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specifies the associated port's serial number in the current port's context." ::= { cPtpClockPortAssociateEntry 5 } cPtpClockPortAssociateAddressType OBJECT-TYPE SYNTAX InetAddressType -- Rsyntax INTEGER { -- ?? enum value of zero may cause problems -- unknown(0), -- ipv4(1), -- ipv6(2), -- ipv4z(3), -- ipv6z(4), -- dns(16) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the peer port's network address type used for PTP communication." ::= { cPtpClockPortAssociateEntry 6 } cPtpClockPortAssociateAddress OBJECT-TYPE SYNTAX InetAddress -- Rsyntax OCTET STRING(SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the peer port's network address used for PTP communication." ::= { cPtpClockPortAssociateEntry 7 } cPtpClockPortAssociatePacketsSent OBJECT-TYPE SYNTAX --?? syntax is not convertable to SMIv1 Counter -- Units -- packets ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets sent to this peer port from the current port." ::= { cPtpClockPortAssociateEntry 8 } cPtpClockPortAssociatePacketsReceived OBJECT-TYPE SYNTAX --?? syntax is not convertable to SMIv1 Counter -- Units -- packets ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets received from this peer port by the current port." ::= { cPtpClockPortAssociateEntry 9 } cPtpClockPortAssociateInErrors OBJECT-TYPE SYNTAX --?? syntax is not convertable to SMIv1 Counter -- Units -- packets ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the input errors associated with the peer port." ::= { cPtpClockPortAssociateEntry 10 } cPtpClockPortAssociateOutErrors OBJECT-TYPE SYNTAX --?? syntax is not convertable to SMIv1 Counter -- Units -- packets ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the output errors associated with the peer port." ::= { cPtpClockPortAssociateEntry 11 } ciscoPtpMIBSystemInfoGroup OBJECT IDENTIFIER ::= { ciscoPtpMIBGroups 1 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- Group which aggregates objects describing system-wide -- information -- objects -- cPtpSystemDomainTotals, cPtpDomainClockPortsTotal, -- cPtpDomainClockPortPhysicalInterfacesTotal, -- cPtpClockInput1ppsEnabled, cPtpClockOutput1ppsEnabled, -- cPtpClockOutput1ppsOffsetEnabled, -- cPtpClockInputFrequencyEnabled, cPtpClockTODEnabled, -- cPtpClockOutput1ppsOffsetValue, -- cPtpClockOutput1ppsOffsetNegative, cPtpSystemProfile, -- cPtpClockInput1ppsInterface, cPtpClockOutput1ppsInterface, -- cPtpClockTODInterface ciscoPtpMIBClockCurrentDSGroup OBJECT IDENTIFIER ::= { ciscoPtpMIBGroups 2 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- Group which aggregates objects describing PTP Current Dataset -- information -- objects -- cPtpClockCurrentDSStepsRemoved, -- cPtpClockCurrentDSOffsetFromMaster, -- cPtpClockCurrentDSMeanPathDelay ciscoPtpMIBClockParentDSGroup OBJECT IDENTIFIER ::= { ciscoPtpMIBGroups 3 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- Group which aggregates objects describing PTP Parent Dataset -- information -- objects -- cPtpClockParentDSParentPortIdentity, -- cPtpClockParentDSParentStats, cPtpClockParentDSOffset, -- cPtpClockParentDSClockPhChRate, -- cPtpClockParentDSGMClockIdentity, -- cPtpClockParentDSGMClockPriority1, -- cPtpClockParentDSGMClockPriority2, -- cPtpClockParentDSGMClockQualityClass, -- cPtpClockParentDSGMClockQualityAccuracy, -- cPtpClockParentDSGMClockQualityOffset ciscoPtpMIBClockDefaultDSGroup OBJECT IDENTIFIER ::= { ciscoPtpMIBGroups 4 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- Group which aggregates objects describing PTP Default Dataset -- information -- objects -- cPtpClockDefaultDSTwoStepFlag, -- cPtpClockDefaultDSClockIdentity, cPtpClockDefaultDSPriority1, -- cPtpClockDefaultDSPriority2, cPtpClockDefaultDSSlaveOnly, -- cPtpClockDefaultDSQualityClass, -- cPtpClockDefaultDSQualityAccuracy, -- cPtpClockDefaultDSQualityOffset ciscoPtpMIBClockRunningGroup OBJECT IDENTIFIER ::= { ciscoPtpMIBGroups 5 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- Group which aggregates objects describing PTP running state -- information -- objects -- cPtpClockRunningState, cPtpClockRunningPacketsSent, -- cPtpClockRunningPacketsReceived ciscoPtpMIBClockTimepropertiesGroup OBJECT IDENTIFIER ::= { ciscoPtpMIBGroups 6 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- Group which aggregates objects describing PTP Time Properties -- information -- objects -- cPtpClockTimePropertiesDSCurrentUTCOffsetValid, -- cPtpClockTimePropertiesDSCurrentUTCOffset, -- cPtpClockTimePropertiesDSLeap59, -- cPtpClockTimePropertiesDSLeap61, -- cPtpClockTimePropertiesDSTimeTraceable, -- cPtpClockTimePropertiesDSFreqTraceable, -- cPtpClockTimePropertiesDSPTPTimescale, -- cPtpClockTimePropertiesDSSource ciscoPtpMIBClockTranparentDSGroup OBJECT IDENTIFIER ::= { ciscoPtpMIBGroups 7 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- Group which aggregates objects describing PTP Transparent -- Dataset -- information -- objects -- cPtpClockTransDefaultDSClockIdentity, -- cPtpClockTransDefaultDSNumOfPorts, -- cPtpClockTransDefaultDSDelay, -- cPtpClockTransDefaultDSPrimaryDomain ciscoPtpMIBClockPortGroup OBJECT IDENTIFIER ::= { ciscoPtpMIBGroups 8 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- Group which aggregates objects describing information for a -- given PTP Port. -- objects -- cPtpClockPortName, cPtpClockPortSyncOneStep, -- cPtpClockPortCurrentPeerAddress, -- cPtpClockPortNumOfAssociatedPorts, -- cPtpClockPortCurrentPeerAddressType, cPtpClockPortRole ciscoPtpMIBClockPortDSGroup OBJECT IDENTIFIER ::= { ciscoPtpMIBGroups 9 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- Group which aggregates objects describing PTP Port Dataset -- information -- objects -- cPtpClockPortDSName, cPtpClockPortDSPortIdentity, -- cPtpClockPortDSAnnouncementInterval, -- cPtpClockPortDSAnnounceRctTimeout, -- cPtpClockPortDSSyncInterval, -- cPtpClockPortDSMinDelayReqInterval, -- cPtpClockPortDSPeerDelayReqInterval, cPtpClockPortDSDelayMech, -- cPtpClockPortDSPeerMeanPathDelay, -- cPtpClockPortDSGrantDuration, cPtpClockPortDSPTPVersion ciscoPtpMIBClockPortRunningGroup OBJECT IDENTIFIER ::= { ciscoPtpMIBGroups 10 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- Group which aggregates objects describing PTP running interface -- information -- objects -- cPtpClockPortRunningName, cPtpClockPortRunningState, -- cPtpClockPortRunningRole, cPtpClockPortRunningInterfaceIndex, -- cPtpClockPortRunningIPversion, -- cPtpClockPortRunningEncapsulationType, -- cPtpClockPortRunningTxMode, cPtpClockPortRunningRxMode, -- cPtpClockPortRunningPacketsReceived, -- cPtpClockPortRunningPacketsSent ciscoPtpMIBClockPortTransDSGroup OBJECT IDENTIFIER ::= { ciscoPtpMIBGroups 11 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- Group which aggregates objects describing PTP TransparentDS -- Dataset -- information -- objects -- cPtpClockPortTransDSPortIdentity, -- cPtpClockPortTransDSlogMinPdelayReqInt, -- cPtpClockPortTransDSFaultyFlag, -- cPtpClockPortTransDSPeerMeanPathDelay ciscoPtpMIBClockPortAssociateGroup OBJECT IDENTIFIER ::= { ciscoPtpMIBGroups 12 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- Group which aggregates objects describing information on peer -- PTP ports for a given PTP clock-port. -- objects -- cPtpClockPortAssociatePacketsSent, -- cPtpClockPortAssociatePacketsReceived, -- cPtpClockPortAssociateAddress, -- cPtpClockPortAssociateAddressType, -- cPtpClockPortAssociateInErrors, -- cPtpClockPortAssociateOutErrors ciscoPtpMIBCompliances1 OBJECT IDENTIFIER ::= { ciscoPtpMIBCompliances 1 } -- MODULE-COMPLIANCE -- Status -- mandatory -- Descr -- Compliance statement for agents that provide read-only support -- for CISCO-PTP-MIB. Such devices can only be monitored using this -- MIB module. -- -- The Module is implemented with support for read-only. In other -- words, only monitoring is available by implementing this -- MODULE-COMPLIANCE. -- Module -- >>current<< -- MandGroup -- ciscoPtpMIBSystemInfoGroup ciscoPtpMIBCompliances2 OBJECT IDENTIFIER ::= { ciscoPtpMIBCompliances 2 } -- MODULE-COMPLIANCE -- Status -- mandatory -- Descr -- Compliance statement for agents that provide read-only support -- for CISCO-PTP-MIB. Such devices can only be monitored using this -- MIB module. -- -- The Module is implemented with support for read-only. In other -- words, only monitoring is available by implementing this -- MODULE-COMPLIANCE. -- Module -- >>current<< -- MandGroup -- ciscoPtpMIBClockCurrentDSGroup -- MandGroup -- ciscoPtpMIBClockParentDSGroup -- MandGroup -- ciscoPtpMIBClockDefaultDSGroup -- MandGroup -- ciscoPtpMIBClockRunningGroup -- MandGroup -- ciscoPtpMIBClockTimepropertiesGroup ciscoPtpMIBCompliances3 OBJECT IDENTIFIER ::= { ciscoPtpMIBCompliances 3 } -- MODULE-COMPLIANCE -- Status -- mandatory -- Descr -- Compliance statement for agents that provide read-only support -- for CISCO-PTP-MIB. Such devices can only be monitored using this -- MIB module. -- -- The Module is implemented with support for read-only. In other -- words, only monitoring is available by implementing this -- MODULE-COMPLIANCE. -- Module -- >>current<< -- MandGroup -- ciscoPtpMIBClockPortGroup -- MandGroup -- ciscoPtpMIBClockPortDSGroup -- MandGroup -- ciscoPtpMIBClockPortRunningGroup -- MandGroup -- ciscoPtpMIBClockPortAssociateGroup ciscoPtpMIBCompliances4 OBJECT IDENTIFIER ::= { ciscoPtpMIBCompliances 4 } -- MODULE-COMPLIANCE -- Status -- mandatory -- Descr -- Compliance statement for agents that provide read-only support -- for CISCO-PTP-MIB. Such devices can only be monitored using this -- MIB module. -- -- The Module is implemented with support for read-only. In other -- words, only monitoring is available by implementing this -- MODULE-COMPLIANCE. -- Module -- >>current<< -- MandGroup -- ciscoPtpMIBClockTranparentDSGroup -- MandGroup -- ciscoPtpMIBClockPortTransDSGroup END