-- -- IRT4570MDC-MIB.my (MIB for MDC-4570) -- v2.0 06/10/2009 -- - MIB regenerated for MIB Browser compataibility. -- v1.0 08/01/2009 -- - Original Issue. -- -- -- IRT4570MDC-MIB DEFINITIONS ::= BEGIN IMPORTS irtProducts, irt FROM IRT-MIB OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 sysObjectID, sysName, DisplayString FROM RFC1213-MIB; -- -- Node definitions -- -- 1.3.6.1.4.1.16557.3.50 irt4570MDC OBJECT IDENTIFIER ::= { irtProducts 50 } -- 1.3.6.1.4.1.16557.3.50.1 alarms OBJECT-TYPE SYNTAX INTEGER { noAlarms(1), urgentAlarms(2), nonUrgentAlarms(3), urgAndNonUrgentAlarms(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The current state of the Urgent and Non Urgent alarms." ::= { irt4570MDC 1 } -- 1.3.6.1.4.1.16557.3.50.2 switchStatus OBJECT IDENTIFIER ::= { irt4570MDC 2 } -- 1.3.6.1.4.1.16557.3.50.2.1 scrambleSwitch OBJECT-TYPE SYNTAX INTEGER { none(1), scramble(2), descramble(3) } ACCESS read-only STATUS mandatory DESCRIPTION "An indication of the front panel switch setting." ::= { switchStatus 1 } -- 1.3.6.1.4.1.16557.3.50.2.2 reedSolomonSwitch OBJECT-TYPE SYNTAX INTEGER { none(1), rsencode(2), rsdecode(3) } ACCESS read-only STATUS mandatory DESCRIPTION "An indication of the front panel switch setting." ::= { switchStatus 2 } -- 1.3.6.1.4.1.16557.3.50.2.3 interleaverSwitch OBJECT-TYPE SYNTAX INTEGER { none(1), interleave(2), deinterleave(3) } ACCESS read-only STATUS mandatory DESCRIPTION "An indication of the front panel switch setting." ::= { switchStatus 3 } -- 1.3.6.1.4.1.16557.3.50.2.4 pkt188to204Switch OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } ACCESS read-only STATUS mandatory DESCRIPTION "An indication of the DIP switch setting." ::= { switchStatus 4 } -- 1.3.6.1.4.1.16557.3.50.2.5 pkt204to188Switch OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } ACCESS read-only STATUS mandatory DESCRIPTION "An indication of the DIP switch setting." ::= { switchStatus 5 } -- 1.3.6.1.4.1.16557.3.50.3 inputStatus OBJECT IDENTIFIER ::= { irt4570MDC 3 } -- 1.3.6.1.4.1.16557.3.50.3.1 inputPresent OBJECT-TYPE SYNTAX INTEGER { notPresent(1), present(2) } ACCESS read-only STATUS mandatory DESCRIPTION "An indication that a signal is present." ::= { inputStatus 1 } -- 1.3.6.1.4.1.16557.3.50.3.2 inputPktSize OBJECT-TYPE SYNTAX INTEGER { bytes188(1), bytes204(2) } ACCESS read-only STATUS mandatory DESCRIPTION "An indication of the packet size." ::= { inputStatus 2 } -- 1.3.6.1.4.1.16557.3.50.3.3 inputDataRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The approximate input data rate." ::= { inputStatus 3 } -- 1.3.6.1.4.1.16557.3.50.3.4 inputSCRpres OBJECT-TYPE SYNTAX INTEGER { notPresent(1), present(2) } ACCESS read-only STATUS mandatory DESCRIPTION "An indication that the input has energy dispersal scrambling added." ::= { inputStatus 4 } -- 1.3.6.1.4.1.16557.3.50.3.5 inputRSpres OBJECT-TYPE SYNTAX INTEGER { notPresent(1), present(2) } ACCESS read-only STATUS mandatory DESCRIPTION "An indication that the input has RS bytes." ::= { inputStatus 5 } -- 1.3.6.1.4.1.16557.3.50.4 rsErrorMonitor OBJECT IDENTIFIER ::= { irt4570MDC 4 } -- 1.3.6.1.4.1.16557.3.50.4.1 rsErrMonActive OBJECT-TYPE SYNTAX INTEGER { notEnabled(1), enabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enables RS error monitoring. A set with the value 2 sent to this OID will reset all error counters to 0. Note that this requires the correct switch and input signal status to operate correctly." ::= { rsErrorMonitor 1 } -- 1.3.6.1.4.1.16557.3.50.4.2 rsCorrectibleErr OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The acccumulated number of correctible RS errors." ::= { rsErrorMonitor 2 } -- 1.3.6.1.4.1.16557.3.50.4.3 rsUncorrectibleErr OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The acccumulated number of uncorrectible RS errors." ::= { rsErrorMonitor 3 } -- 1.3.6.1.4.1.16557.3.50.4.4 rsSyncLossPeriod OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The acccumulated number of sync loss periods." ::= { rsErrorMonitor 4 } -- 1.3.6.1.4.1.16557.3.50.5 inputAlias OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A 15 byte maximum Alias for the Input." ::= { irt4570MDC 5 } -- 1.3.6.1.4.1.16557.3.50.6 fpgaVersion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The firmware version of the main FPGA in the format 'x.y' where x is the major revision number and y is the minor revision number." ::= { irt4570MDC 6 } -- 1.3.6.1.4.1.16557.3.50.7 softwareVersion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The software version of the main FPGA in the format 'x.y' where x is the major revision number and y is the minor revision number." ::= { irt4570MDC 7 } -- 1.3.6.1.4.1.16557.3.50.8 reset OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A set with the value 2 sent to this OID will cause a system reset to occur. When queried returns a 1." ::= { irt4570MDC 8 } -- 1.3.6.1.4.1.16557.3.50.9 inputPresTrapEnable OBJECT-TYPE SYNTAX INTEGER { notEnabled(1), enabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "If enabled, traps will be sent when the input is first present or first lost." ::= { irt4570MDC 9 } -- 1.3.6.1.4.1.16557.3.50.10 rsUncorrectibleErrorTrapEnable OBJECT-TYPE SYNTAX INTEGER { notEnabled(1), enabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "If enabled, a trap will be sent when an RS uncorrectible errored period occurs." ::= { irt4570MDC 10 } -- 1.3.6.1.4.1.16557.3.50.11 rsCorrectibleErrorTrapEnable OBJECT-TYPE SYNTAX INTEGER { notEnabled(1), enabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "If enabled, a trap will be sent when an RS correctible errored period occurs." ::= { irt4570MDC 11 } -- -- Trap definitions -- irt4570MDCinputStatusTrap TRAP-TYPE ENTERPRISE irt VARIABLES { sysObjectID, sysName, inputPresent } DESCRIPTION "If enabled, a trap will be sent when the input is first present or first lost." ::= 50 irt4570MDCrsUncorrectibleErrorTrap TRAP-TYPE ENTERPRISE irt VARIABLES { sysObjectID, sysName, rsErrMonActive, rsUncorrectibleErr } DESCRIPTION "If enabled, a trap will be sent when an RS uncorrectible errored period occurs." ::= 178 irt4570MDCrsCorrectibleErrorTrap TRAP-TYPE ENTERPRISE irt VARIABLES { sysObjectID, sysName, rsErrMonActive, rsCorrectibleErr } DESCRIPTION "If enabled, a trap will be sent when an RS correctible errored period occurs." ::= 306 END -- -- IRT4570MDC-MIB.my --