-- -- Copyright 1999 by Fore Systems, Inc. -- Converted to SMIv2 rfc 2578,2579,2580 - STD 58 -- -- ($Id: //depot/prod/switch/smf/src/snmp/mibs/fore-common.mib#8 $) -- Copyright 1993-1995 by Fore Systems, Inc. Fore-Common-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises, TimeTicks, Integer32, MODULE-IDENTITY FROM SNMPv2-SMI; ------------------------------------------------------------------------ fore MODULE-IDENTITY LAST-UPDATED "9911050000Z" ORGANIZATION "FORE" CONTACT-INFO " Postal: FORE Systems Inc. 1000 FORE Drive Warrendale, PA 15086-7502 Tel: +1 724 742 6900 Email: nm_mibs@fore.com Web: http://www.fore.com" DESCRIPTION "Definitions common to all FORE private MIBS." ::= { enterprises 326 } admin OBJECT IDENTIFIER ::= { fore 1 } systems OBJECT IDENTIFIER ::= { fore 2 } foreExperiment OBJECT IDENTIFIER ::= { fore 3 } operations OBJECT IDENTIFIER ::= { admin 1 } snmpErrors OBJECT IDENTIFIER ::= { admin 2 } fileXfr OBJECT IDENTIFIER ::= { admin 6 } preDot1qVlanMIB OBJECT IDENTIFIER ::= { admin 8 } snmpTrapLog OBJECT IDENTIFIER ::= { admin 9 } ilmisnmp OBJECT IDENTIFIER ::= { admin 10 } ilmiRegistry OBJECT IDENTIFIER ::= { admin 14 } foreIfExtension OBJECT IDENTIFIER ::= { admin 15 } frameInternetworking OBJECT IDENTIFIER ::= { admin 16 } ifExtensions OBJECT IDENTIFIER ::= { admin 17 } atmAdapter OBJECT IDENTIFIER ::= { systems 1 } atmSwitch OBJECT IDENTIFIER ::= { systems 2 } software OBJECT IDENTIFIER ::= { atmSwitch 2 } asxd OBJECT IDENTIFIER ::= { software 1 } hardware OBJECT IDENTIFIER ::= { atmSwitch 1 } asx OBJECT IDENTIFIER ::= { hardware 1 } ------------------------------------------------------------------------ -- Textual Conventions -- The SPANS ATM Address SpansAddress ::= OCTET STRING (SIZE (8)) -- ATM Forum ATM Address (allow E.164 addresses) AtmAddress ::= OCTET STRING (SIZE (8 | 20)) -- The NsapPrefix type if used by Q2931 signalling -- for setting ATM address. NsapPrefix ::= OCTET STRING(SIZE(13)) -- The NsapAddress type is used for NSAP (Network Service -- Access Point) routing group tables. NsapAddr ::= OCTET STRING(SIZE(20)) -- Transit Network Selection according to Q2931 signalling -- to identify requested transit networks. TransitNetwork ::= OCTET STRING(SIZE(4)) -- The enterprise specific trap number. TrapNumber ::= Integer32 ------------------------------------------------------------------------ -- MIB Types Definitions -- The status of a table entry. -- Taken from RFC1757-MIB DEFINITIONS -- Setting this object to the value invalid(4) has the -- effect of invalidating the corresponding entry. -- That is, it effectively disassociates the mapping -- identified with said entry. -- It is an implementation-specific matter as to whether -- the agent removes an invalidated entry from the table. -- Accordingly, management stations must be prepared to -- receive tabular information from agents that corresponds -- to entries currently not in use. Proper -- interpretation of such entries requires examination -- of the relevant EntryStatus object. -- -- An existing instance of this object cannot be set to -- createRequest(2). This object may only be set to -- createRequest(2) when this instance is created. When -- this object is created, the agent may wish to create -- supplemental object instances to complete a conceptual -- row in this table. Immediately after completing the -- create operation, the agent must set this object to -- underCreation(3). -- -- Entries shall exist in the underCreation(3) state until -- the management station is finished configuring the -- entry and sets this object to valid(1) or aborts, -- setting this object to invalid(4). If the agent -- determines that an entry has been in the -- underCreation(3) state for an abnormally long time, -- it may decide that the management station has -- crashed. If the agent makes this decision, -- it may set this object to invalid(4) to reclaim the -- entry. A prudent agent will understand that the -- management station may need to wait for human input -- and will allow for that possibility in its -- determination of this abnormally long period. EntryStatus ::= INTEGER { valid(1), createRequest(2), underCreation(3), invalid(4) } -- The type of the signaling protocol that -- created the table entry for the path or channel. -- Note that entry 5, spvc, should be deprecated due -- to the introduction of spvcSpans and spvcPnni. -- spvcPnni will be the protocol for both PNNI SPVCCs and -- PNNI SPVPCs. AtmSigProtocol ::= INTEGER { other (1), spans (2), q2931 (3), pvc (4), spvc (5), oam (6), spvcSpans(7), spvcPnni(8), rcc(9), fsig(10) } -- General State GeneralState ::= INTEGER { normal(1), fail(2) } -- IntegerBitString is a set of bits that will fit into a 32 -- bit integer. The bits are numbered from the low order -- bit as bit 0 to high order bit 31. IntegerBitString ::= Integer32 -- -- ConnectionType -- -- This object identifies the type of the path/channel -- endpoints(ingress and egress) at a switch with respect -- to a particular network. It also indicates whether the -- path/channel is a point-to-point(PP), point-to-multipoint(PMP), -- multipoint-to-point(MPP) or multipoint-to-multipoint(MPMP). -- Used for Call Recording. -- -- ** NOTE ** These values are filled in by the user during the -- creation of a path/channel and hence may not reflect the true -- status of the path/channel. -- -- The ConnectionType type is defined as a bit-mapped value. -- The fields are as follows: -- -- (bits 4 & 5) (bits 2 & 3) (bits 0 & 1) -- The ingress and egress connection types are defined as -- follows: -- Bit map value -- 00 originating -- 01 transit -- 10 terminating -- 11 invalid -- From a billing perspective, even PVPs & PVCs -- have a `source' and a `destination' switch. -- `originating' indicates that the ingress/egress endpoint -- of the path/channel is connected to the `source' node -- which is outside the network. -- `transit' indicates that the ingress/egress endpoint of -- the path/channel is connected to a node within the -- same network. -- `terminating' indicates the ingress/egress endpoint of -- the path/channel is connected to the `destination' node -- which is outside the network. -- The call-type field is defined as follows: -- Bit map value -- 00 PP -- 01 PMP -- 10 MPP -- 11 MPMP -- The call-type field is valid only if the ingress and egress -- connect point types are specified. If the ingress/egress -- connect point types are specified, the call-type defaults to -- `PP' if not specified. -- Example: For a PMP PVC whose ingress side is connected to -- a switch within the same network and whose egress side is -- connected to the `destination' node, the ConnectionType -- variable is going to have a value of 010110(0x16) or 22. -- ConnectionType ::= Integer32 END