-- Stratacom StrataView Network MIBs -- -- $RCSfile: SV+Network.mib,v $ -- $Revision: 1.1.4.2.1 $ -- $Date: 1996/04/29 07:28:57 $ -- -- Consolidated MIB for event, node, filters, rtc and rtm -- -- STRATACOM-STRATAVIEW-SVPLUS-MIB DEFINITIONS ::= BEGIN IMPORTS Gauge FROM RFC1155-SMI DisplayString FROM RFC1213-MIB IpAddress, Counter FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212; internet OBJECT IDENTIFIER ::= { iso(1) org(3) dod(6) 1 } private OBJECT IDENTIFIER ::= { internet 4 } enterprises OBJECT IDENTIFIER ::= { private 1 } stratacom OBJECT IDENTIFIER ::= { enterprises 351 } svplus OBJECT IDENTIFIER ::= { stratacom 1 } svnode OBJECT IDENTIFIER ::= { stratacom 2 } -- connSvc OBJECT IDENTIFIER ::= { stratacom 3 } -- portSvc OBJECT IDENTIFIER ::= { stratacom 4 } rtm OBJECT IDENTIFIER ::= { stratacom 120 } -- strmErrors OBJECT IDENTIFIER ::= { stratacom 910 } -- StrataView Plus Generated events. Added br HJ and Sridhar strataviewEvents OBJECT IDENTIFIER ::= { stratacom 920 } -- -- Note that Object identifiers { svplus 1 } through { svplus 10 } -- have been depricated. -- controlGroup OBJECT IDENTIFIER ::= { svplus 11 } logGroup OBJECT IDENTIFIER ::= { svplus 12 } networkGroup OBJECT IDENTIFIER ::= { svplus 13 } nodeGroup OBJECT IDENTIFIER ::= { svplus 14 } svNodeGroup OBJECT IDENTIFIER ::= { svnode 1 } packetGroup OBJECT IDENTIFIER ::= { svnode 2 } circuitGroup OBJECT IDENTIFIER ::= { svnode 3 } frpGroup OBJECT IDENTIFIER ::= { svnode 4 } connGroup OBJECT IDENTIFIER ::= { svnode 5 } realTimeCountersGroup OBJECT IDENTIFIER ::= { svnode 6 } trapsConfig OBJECT IDENTIFIER ::= { rtm 1 } Active ::= INTEGER { inactive (1), active (2) } -- Values currently used for "severity" in log records and -- TRAP filters are "Clear", "Info", "Minor", "Major", and -- "Updt" (for update). Others may be used in the future. -- Severity ::= DisplayString (SIZE (0..5)) nodeGrpName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..10)) ACCESS read-only STATUS mandatory DESCRIPTION "IPX node name." ::= { svNodeGroup 1 } nodeGrpNetName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..10)) ACCESS read-only STATUS mandatory DESCRIPTION "IPX network name." ::= { svNodeGroup 2 } nodeGrpAlarmState OBJECT-TYPE SYNTAX INTEGER { clear (1), minor (2), major (3), unreachable (5) } ACCESS read-only STATUS mandatory DESCRIPTION "Node Alarm State. Only low 6 bits are valid." ::= { svNodeGroup 3 } nodeGrpGateway OBJECT-TYPE SYNTAX INTEGER { not-a-gateway (1), gateway (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Is this node acting as a gateway?" ::= { svNodeGroup 4 } nodeGrpActive OBJECT-TYPE SYNTAX Active ACCESS read-only STATUS mandatory DESCRIPTION "Active state of this Node." ::= { svNodeGroup 5 } nodeGrpPlatform OBJECT-TYPE SYNTAX INTEGER { ipx-platform (1), bpx-platform (2), axis-platform (3) } ACCESS read-only STATUS mandatory DESCRIPTION "Platform type." ::= { svNodeGroup 6 } nodeGrpRelease OBJECT-TYPE SYNTAX DisplayString (SIZE(0..10)) ACCESS read-only STATUS mandatory DESCRIPTION "StrataView Plus release revision." ::= { svNodeGroup 7 } nodeFsIncRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "FRP Foresight increase rate." ::= { svNodeGroup 8 } nodeFsDecRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "FRP forsight normal decrease rate." ::= { svNodeGroup 9 } nodeFsFastRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "FRP forsight fast decrease rate." ::= { svNodeGroup 10 } nodeRstTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Timeout for resetting PVC rate to QIR." ::= { svNodeGroup 11 } alarmTrapSequenceNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The Sequence Number of the last trap generated on the SNMP Proxy" ::= { svNodeGroup 12 } ----------------------------------------------------------------------- -- Packet Group ----------------------------------------------------------------------- ----------------------------------------------------------------------- -- Packet Line Table has been deleted and replaced by the -- Trunk Table. ----------------------------------------------------------------------- --pktLineTable OBJECT-TYPE -- SYNTAX SEQUENCE OF PktLineEntry -- ACCESS not-accessible -- STATUS mandatory -- DESCRIPTION "The table of Packet Lines." -- ::= { packetGroup 1 } ----------------------------------------------------------------------- -- Trunk Table ----------------------------------------------------------------------- trunkTable OBJECT-TYPE SYNTAX SEQUENCE OF TrunkEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table of Trunk Lines." ::= { packetGroup 2 } trunkEntry OBJECT-TYPE SYNTAX TrunkEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Trunk table." INDEX { trunkLocalSlot, trunkLocalPort } ::= { trunkTable 1 } TrunkEntry ::= SEQUENCE { trunkLocalSlot INTEGER, trunkLocalPort INTEGER, trunkLocalLine INTEGER, trunkCardType INTEGER, trunkInterface INTEGER, trunkLineLoad INTEGER, trunkRemNodeId INTEGER, trunkRemLineNumber INTEGER, trunkRemSlot INTEGER, trunkRemPort INTEGER, trunkAlarmState INTEGER, trunkComment DisplayString, trunkActive Active, trunkStatus INTEGER, trunkStatReserve INTEGER, trunkBurstyDataBQDepth INTEGER, trunkBurstyDataBQEfcnThreshold INTEGER, trunkClpHighDropThreshold INTEGER, trunkClpLowDropThreshold INTEGER } trunkLocalSlot OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Local Slot Number. These are numbered starting at 1." ::= { trunkEntry 1 } trunkLocalPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Local Port Number. These are numbered starting at 1." ::= { trunkEntry 2 } trunkLocalLine OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Local Line Number. These are numbered starting at 1." ::= { trunkEntry 3 } trunkCardType OBJECT-TYPE SYNTAX INTEGER { txr(3), bni(4), ntc(22), atm(31), ait(34), bni-t3(103), bni-e3(104) } ACCESS read-only STATUS mandatory DESCRIPTION "Type of the card supporting the trunk line. The card type is dependant on the value of nodePlatform. Additional types may exist with future hardware." ::= { trunkEntry 4 } trunkInterface OBJECT-TYPE SYNTAX INTEGER { unknown (1), t1-d4 (2), t1-esf (3), e1-30 (4), e1-31 (5), e1-32 (6), subrate (7), atm (8) } ACCESS read-only STATUS mandatory DESCRIPTION "Trunk Line Interface Type. Indicates the format of the packet line." ::= { trunkEntry 5 } trunkLineLoad OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Line Load in packets per second." ::= { trunkEntry 6 } trunkRemNodeId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Remote StrataView Node ID." ::= { trunkEntry 7 } trunkRemLineNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Remote Line Number." ::= { trunkEntry 8 } trunkRemSlot OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Remote Slot Number." ::= { trunkEntry 9 } trunkRemPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Remote Port Number." ::= { trunkEntry 10 } trunkAlarmState OBJECT-TYPE SYNTAX INTEGER { clear (1), info (2), minor (3), major (4) } ACCESS read-only STATUS mandatory DESCRIPTION "Trunk Line Alarm State." ::= { trunkEntry 11 } trunkComment OBJECT-TYPE SYNTAX DisplayString (SIZE(0..20)) ACCESS read-only STATUS mandatory DESCRIPTION "StrataView user entered comment field used to further qualify the trunk line." ::= { trunkEntry 12 } trunkActive OBJECT-TYPE SYNTAX Active ACCESS read-only STATUS mandatory DESCRIPTION "Active State." ::= { trunkEntry 13 } trunkStatus OBJECT-TYPE SYNTAX INTEGER { inactive(1), clear(2), fail(3), down(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Trunk line status." ::= { trunkEntry 14 } trunkStatReserve OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Trunk Line statistical reserve field." ::= { trunkEntry 15 } trunkBurstyDataBQDepth OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Trunk Line bursty data B queue depth." ::= { trunkEntry 16 } trunkBurstyDataBQEfcnThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Trunk Line bursty data B queue EFCN/FFCI threshold." ::= { trunkEntry 17 } trunkClpHighDropThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Trunk Line CLP high dropping threshold." ::= { trunkEntry 18 } trunkClpLowDropThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Trunk Line CLP low dropping threshold." ::= { trunkEntry 19 } ----------------------------------------------------------------------- -- Circuit Group ----------------------------------------------------------------------- ----------------------------------------------------------------------- -- Circuit Line Table ----------------------------------------------------------------------- cirLineTable OBJECT-TYPE SYNTAX SEQUENCE OF CirLineEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table of Circuit Lines." ::= { circuitGroup 1 } cirLineEntry OBJECT-TYPE SYNTAX CirLineEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Circuit Line table." INDEX { cirLineLineNumber } ::= { cirLineTable 1 } CirLineEntry ::= SEQUENCE { cirLineLineNumber INTEGER, cirLineCardType INTEGER, cirLineInterface INTEGER, cirLineComment DisplayString, cirLineActive Active, cirLineStatus INTEGER } cirLineLineNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Circuit Line Number." ::= { cirLineEntry 3 } cirLineCardType OBJECT-TYPE SYNTAX INTEGER { txr (3), cip(21), cdp(29) } ACCESS read-only STATUS mandatory DESCRIPTION "Circuit Card Type." ::= { cirLineEntry 4 } cirLineInterface OBJECT-TYPE SYNTAX INTEGER { unknown (1), t1 (2), e1(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Circuit Line Interface Type. Indicates the format of the circuit line." ::= { cirLineEntry 5 } cirLineComment OBJECT-TYPE SYNTAX DisplayString (SIZE(0..22)) ACCESS read-only STATUS mandatory DESCRIPTION "Comment entered by StrataView user to further qualify the Circuit Line." ::= { cirLineEntry 6 } cirLineActive OBJECT-TYPE SYNTAX Active ACCESS read-only STATUS mandatory DESCRIPTION "Circuit Line Active State." ::= { cirLineEntry 7 } cirLineStatus OBJECT-TYPE SYNTAX INTEGER { inactive(1), clear(2), fail(3), down(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Circuit Line Status." ::= { cirLineEntry 8 } ----------------------------------------------------------------------- -- Frame Relay Port Group ----------------------------------------------------------------------- ----------------------------------------------------------------------- -- Frame Relay Port Table ----------------------------------------------------------------------- frpTable OBJECT-TYPE SYNTAX SEQUENCE OF FrpEntry ACCESS not-accessible STATUS obsolete DESCRIPTION "The table of Frame Relay Ports." ::= { frpGroup 1 } frpEntry OBJECT-TYPE SYNTAX FrpEntry ACCESS not-accessible STATUS obsolete DESCRIPTION "An entry in the Frame Relay Ports table." INDEX { frpLocalSlot, frpLocalPort } ::= { frpTable 1 } FrpEntry ::= SEQUENCE { frpLocalSlot INTEGER, frpLocalPort INTEGER, frpPortSpeed INTEGER, frpComment DisplayString, frpActive Active, frpStatus INTEGER, frpQDepth INTEGER, frpEcnThreshold INTEGER, frpDeThreshold INTEGER, frpPortType INTEGER, frpLocalLine INTEGER } frpLocalSlot OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS obsolete DESCRIPTION "Local Slot Number." ::= { frpEntry 3 } frpLocalPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS obsolete DESCRIPTION "Local Port Number. These are numbered starting at 1." ::= { frpEntry 4 } frpPortSpeed OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS obsolete DESCRIPTION "Port Speed in bits per second." ::= { frpEntry 5 } frpComment OBJECT-TYPE SYNTAX DisplayString (SIZE(0..22)) ACCESS read-only STATUS obsolete DESCRIPTION "StrataView User comment used to further qualify the Frame Relay Port." ::= { frpEntry 6 } frpActive OBJECT-TYPE SYNTAX Active ACCESS read-only STATUS obsolete DESCRIPTION "Frame Relay Port Active State." ::= { frpEntry 7 } frpStatus OBJECT-TYPE SYNTAX INTEGER { inactive(1), clear(2), fail(3), down(4) } ACCESS read-only STATUS obsolete DESCRIPTION "Frame Relay Port Status." ::= { frpEntry 8 } frpQDepth OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS obsolete DESCRIPTION "Frame Relay Port queue depth." ::= { frpEntry 9 } frpEcnThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS obsolete DESCRIPTION "Frame Relay Port ECN queue threshold." ::= { frpEntry 10 } frpDeThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS obsolete DESCRIPTION "Frame Relay Port DE threshold." ::= { frpEntry 11 } frpPortType OBJECT-TYPE SYNTAX INTEGER { uni(1), nni(2), aip(3), not-defined(4), frsm(5), portConcent(6) } ACCESS read-only STATUS obsolete DESCRIPTION "Frame relay port type. " ::= { frpEntry 12 } frpLocalLine OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Local Line Number." ::= { frpEntry 13 } ----------------------------------------------------------------------- -- Connection Group ----------------------------------------------------------------------- ----------------------------------------------------------------------- -- Connection Table ----------------------------------------------------------------------- connTable OBJECT-TYPE SYNTAX SEQUENCE OF ConnEntry ACCESS not-accessible STATUS obsolete DESCRIPTION "The table of Connections." ::= { connGroup 1 } connEntry OBJECT-TYPE SYNTAX ConnEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Connections table." INDEX { connLocalSlot, connLocalChannel, connLocalDLCI } ::= { connTable 1 } ConnEntry ::= SEQUENCE { connLocalSlot INTEGER, connLocalChannel INTEGER, connLocalDLCI INTEGER, connRemoteNodeId INTEGER, connRemoteSlot INTEGER, connRemoteChannel INTEGER, connRemoteDLCI INTEGER, connType INTEGER, connRate INTEGER, connLocalMaxPkts INTEGER, connRemoteMaxPkts INTEGER, connMinBandwidth INTEGER, connDAX INTEGER, connTXR INTEGER, connComment DisplayString, connActive Active, connStatus INTEGER, connQir INTEGER, connPir INTEGER, connVcQueDepth INTEGER, connVcQueThreshold INTEGER, connCMax INTEGER, connPerUtil INTEGER, connConnInfoFlag INTEGER, connCir INTEGER, connABitStatus INTEGER, connLocalLine INTEGER } connLocalSlot OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Local Slot Number." ::= { connEntry 3 } connLocalChannel OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Local Channel Number. These are numbered starting at 1." ::= { connEntry 4 } connLocalDLCI OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Local DLCI Number." ::= { connEntry 5 } connRemoteNodeId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Remote StrataView Node ID." ::= { connEntry 6 } connRemoteSlot OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Remote Slot Number." ::= { connEntry 7 } connRemoteChannel OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Remote Channel Number. These are numbered starting at 1." ::= { connEntry 8 } connRemoteDLCI OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Remote DLCI Number." ::= { connEntry 9 } connType OBJECT-TYPE SYNTAX INTEGER { voice-dsi-adpcm (1), voice-dsi (2), voice (3), voice-adpcm (4), data (5), frame-relay (6) } ACCESS read-only STATUS mandatory DESCRIPTION "Connection Type." ::= { connEntry 10 } connRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Combination Field of Rate Info. The value for this variable is generated by ORing together the following: 0x80 -> Fast Eia Enabled 0x40 -> DFM Enabled 0x08 -> 7/8 Encoding 0x10 -> 8/8 Encoding 0x18 -> 8/8 Inverted Encoding 0x20 -> 7/8 Inverted Encoding 0x01 -> Voice 0x02 -> Non-Time Stamped 0x03 -> Time Stamped 0x04 -> bursty data 0x05 -> multicast These form four fields: bit 7, bit 6, bits 3-5, and bits 0-2." ::= { connEntry 11 } connLocalMaxPkts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Local maximum number of packets per second allocated." ::= { connEntry 12 } connRemoteMaxPkts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Remote maximum number of packets per second allocated." ::= { connEntry 13 } connMinBandwidth OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Minimum guaranteed bandwidth in bits per second. Zero if not meaningful." ::= { connEntry 14 } connDAX OBJECT-TYPE SYNTAX INTEGER { non-dax(1), dax(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Flag to identify DAX connection." ::= { connEntry 15 } connTXR OBJECT-TYPE SYNTAX INTEGER { non-txr(1), txr(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Flag to identify voice connection end point card is TXR card type." ::= { connEntry 16 } connComment OBJECT-TYPE SYNTAX DisplayString (SIZE(0..22)) ACCESS read-only STATUS mandatory DESCRIPTION "StrataView user entered comment field used to further qualify the connection." ::= { connEntry 17 } connActive OBJECT-TYPE SYNTAX Active ACCESS read-only STATUS mandatory DESCRIPTION "Connection Active State." ::= { connEntry 18 } connStatus OBJECT-TYPE SYNTAX INTEGER { inactive(1), clear(2), fail(3), down(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Connection Status." ::= { connEntry 19 } connQir OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Connection QIR. (bits per sec)" ::= { connEntry 20 } connPir OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Connection PIR." ::= { connEntry 21 } connVcQueDepth OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Connection VcQueDepth." ::= { connEntry 22 } connVcQueThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Connection VcQueThreshold." ::= { connEntry 23 } connCMax OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Connection maximum threshold for FRP credit manager." ::= { connEntry 24 } connPerUtil OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Connection Percent utilization." ::= { connEntry 25 } connConnInfoFlag OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Connection information flags. The flags are define as: bit 6 snaPriorityHigh - decimal 64 bit 7 forsightEnabled - decimal 128 A value of 0 indicates no bits are set." ::= { connEntry 26 } connCir OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Connection CIR.(bits per sec)" ::= { connEntry 27 } connABitStatus OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Connection Bit status field. The fields defined are: bit 6 remotePacketLine - decimal 64 bit 7 aBitOk - decimal 128. A value of 0 indicates no bits are set." ::= { connEntry 28 } connLocalLine OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Local Line Number. Valid only for AXIS" ::= { connEntry 29 } -- -- Real Time Counters Group -- -- -- packet Line Real Time Counters table has been deleted and replace by -- the TrunkLine Real Time Counters table beginning with -- StrataView Plus release ??? -- --PktLineRTCTable OBJECT-TYPE -- SYNTAX SEQUENCE OF PktLineRTCEntry -- ACCESS not-accessible -- STATUS mandatory -- DESCRIPTION "The table of Packet s Line statistics." -- ::= { realTimeCountersGroup 1 } -- -- circuit Line Real Time Counters table -- cirLineRTCTable OBJECT-TYPE SYNTAX SEQUENCE OF CirLineRTCEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table of Circuit Line statistics." ::= { realTimeCountersGroup 2 } cirLineRTCEntry OBJECT-TYPE SYNTAX CirLineRTCEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Circuit Line statistics table. Each row may be sparse." INDEX { cirLineRTCLineNumber } ::= { cirLineRTCTable 1 } CirLineRTCEntry ::= SEQUENCE { -- -- All of the Counters in this table can be very time-expensive -- to retrieve, taking as much as 10 seconds each. -- Manger timeout values should be adjusted accordingly, and -- Get-Next walks through this portion of the table should be -- avoided. -- cirLineRTCLineNumber INTEGER, cirLineRTCBipolarViolations Counter, cirLineRTCFrameSlips Counter, cirLineRTCOutOfFrames Counter, cirLineRTCLossesOfSignal Counter, cirLineRTCFrameBitErrors Counter, cirLineRTCCrcErrors Counter, cirLineRTCOutOfMultiFrames Counter, cirLineRTCAllOnesInTimeslot16 Counter } cirLineRTCLineNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Circuit Line Number." ::= { cirLineRTCEntry 1 } cirLineRTCBipolarViolations OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of bipolar violations which have occurred on the line. This statistic is valid for T1 circuits only." ::= { cirLineRTCEntry 4 } cirLineRTCFrameSlips OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frame slips which have occurred on the receive side of the line. This statistic is valid for TXR lines only. CIP and CDP cards do not support this statistic." ::= { cirLineRTCEntry 5 } cirLineRTCOutOfFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of 0 -> 1 transitions of the out of frame conditions as detected by the hardware." ::= { cirLineRTCEntry 6 } cirLineRTCLossesOfSignal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of 0 -> 1 transitions of the loss of signal condition as detected by the hardware. This statistic is valid on CIP and CDP lines only. TXR lines do not support this statistic." ::= { cirLineRTCEntry 7 } cirLineRTCFrameBitErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frame alignment signal errors which are detected on a line. This statistic is valid only on lines supported by CIP and CDP cards. TXR cards do not support this statistic." ::= { cirLineRTCEntry 8 } cirLineRTCCrcErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of CRC errors detected on the line. This statistic is valid on lines supported by CIP and CDP cards. TXR cards do no support this statistic." ::= { cirLineRTCEntry 9 } cirLineRTCOutOfMultiFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of 0 -> 1 transitions into out of multi-frame as detected by the hardware. This statistic is valid only on E1 lines. T1 lines do not support this statistic." ::= { cirLineRTCEntry 10 } cirLineRTCAllOnesInTimeslot16 OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of 0 -> 1 transitions of AIS-16. This statistic is valid only for CIP and CDP E1 format lines." ::= { cirLineRTCEntry 11 } -- -- Frame relay Real Time Counters table -- frpRTCTable OBJECT-TYPE SYNTAX SEQUENCE OF FrpRTCEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table of frame relay statistics." ::= { realTimeCountersGroup 3 } frpRTCEntry OBJECT-TYPE SYNTAX FrpRTCEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the frame relay statistics table. Each row may be sparse." INDEX { frpRTCSlot, frpRTCPort } ::= { frpRTCTable 1 } FrpRTCEntry ::= SEQUENCE { -- -- All of the Counters in this table can be very time-expensive -- to retrieve, taking as much as 10 seconds each. -- Manger timeout values should be adjusted accordingly, and -- Get-Next walks through this portion of the table should be -- avoided. -- frpRTCSlot INTEGER, frpRTCPort INTEGER, frpRTCFramesRcvd Counter, frpRTCFramesXmitted Counter, frpRTCBytesRcvd Counter, frpRTCBytesXmitted Counter, frpRTCFramesXmittedWithFECN Counter, frpRTCFramesXmittedWithBECN Counter, frpRTCFramesRcvdCrcErrors Counter, frpRTCFramesRcvdInvalidFormat Counter, frpRTCFramesRcvdAlignmentErrors Counter, frpRTCFramesRcvdIllegalLen Counter, frpRTCDmaOverruns Counter, frpRTCLmiStatusEnquires Counter, frpRTCLmiStatusXmitRate Counter, frpRTCLmiStatusUpdateRate Counter, frpRTCLmiInvalidStatusEnquires Counter, frpRTCLmiLinkTimeoutErrors Counter, frpRTCLmiKeepaliveSequenceErrors Counter, frpRTCFramesRcvdUndefDlciErrors Counter, frpRTCXmitStatusEnquirey Counter, frpRTCRxStatusCounter Counter, frpRTCAsyncStatusCounter Counter, frpRTCBadSequenceNumberCount Counter, frpRTCTxProtocolTimeOutCount Counter, frpRTCCLLMFramesTx Counter, frpRTCCLLMBytesTx Counter, frpRTCCLLMFramesRx Counter, frpRTCCLLMBytesRx Counter, frpRTCCLLMFailures Counter, frpRTCRxDEFramesDiscarded Counter, frpRTCLine INTEGER } frpRTCSlot OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Local Slot Number." ::= { frpRTCEntry 1 } frpRTCPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Local Port Number. These are numbered starting at 1." ::= { frpRTCEntry 2 } frpRTCFramesRcvd OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames received by the FRP port." ::= { frpRTCEntry 4 } frpRTCFramesXmitted OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames transmitted out the FRP port." ::= { frpRTCEntry 5 } frpRTCBytesRcvd OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frame bytes received from the FRP port." ::= { frpRTCEntry 6 } frpRTCBytesXmitted OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frame bytes transmitted out the FRP port." ::= { frpRTCEntry 7 } frpRTCFramesXmittedWithFECN OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames transmitted out the FRP port with the FECN bit set." ::= { frpRTCEntry 8 } frpRTCFramesXmittedWithBECN OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames transmitted out the FRP port with the BECN bit set." ::= { frpRTCEntry 9 } frpRTCFramesRcvdCrcErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of CRC errors on received frames for the FRP port." ::= { frpRTCEntry 10 } frpRTCFramesRcvdInvalidFormat OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames received by the FRP port which contain incorrect EA bit settings (1 in the first byte and/or 0 in the second byte)." ::= { frpRTCEntry 11 } frpRTCFramesRcvdAlignmentErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of bit alignment errors on received frames for the FRP port." ::= { frpRTCEntry 12 } frpRTCFramesRcvdIllegalLen OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames received by the FRP port which exceed the maximum allowed frame length." ::= { frpRTCEntry 13 } frpRTCDmaOverruns OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of DMA overruns on the FRP port." ::= { frpRTCEntry 14 } frpRTCLmiStatusEnquires OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of LMI status enquires received from the user device by the FRP port." ::= { frpRTCEntry 15 } frpRTCLmiStatusXmitRate OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of LMI status messages transmitted to the user device from the FRP port per ??." ::= { frpRTCEntry 16 } frpRTCLmiStatusUpdateRate OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of LMI update messages transmitted to the user device from the FRP port per ??." ::= { frpRTCEntry 17 } frpRTCLmiInvalidStatusEnquires OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of invalid LMI status enquires received from the user device by the FRP port." ::= { frpRTCEntry 18 } frpRTCLmiLinkTimeoutErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of LMI link timeout errors." ::= { frpRTCEntry 19 } frpRTCLmiKeepaliveSequenceErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of LMI keepalive sequence number errors." ::= { frpRTCEntry 20 } frpRTCFramesRcvdUndefDlciErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames received by the FRP port which contain undefined DLCIs." ::= { frpRTCEntry 21 } frpRTCXmitStatusEnquirey OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Transmit Status Enquirey." ::= { frpRTCEntry 22 } frpRTCRxStatusCounter OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Received Status counter." ::= { frpRTCEntry 23 } frpRTCAsyncStatusCounter OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Asynchronous Status Counter." ::= { frpRTCEntry 24 } frpRTCBadSequenceNumberCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Invalid Sequence number count." ::= { frpRTCEntry 25 } frpRTCTxProtocolTimeOutCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Transmit Protocol timeout count." ::= { frpRTCEntry 26 } frpRTCCLLMFramesTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "CLLM message frames transmitted." ::= { frpRTCEntry 27 } frpRTCCLLMBytesTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "CLLM message bytes transmitted." ::= { frpRTCEntry 28 } frpRTCCLLMFramesRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "CLLM Frames received." ::= { frpRTCEntry 29 } frpRTCCLLMBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "CLLM bytes received." ::= { frpRTCEntry 30 } frpRTCCLLMFailures OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "CLLM failures." ::= { frpRTCEntry 31 } frpRTCRxDEFramesDiscarded OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames with the DE bit set which have been dropped by the frame relay port. IPX software versions earlier than IPX 6.1 will report a count of zero." ::= { frpRTCEntry 32} frpRTCLine OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Local Slot Number." ::= { frpRTCEntry 33 } -- -- Connection Real Time Counters Table -- connRTCTable OBJECT-TYPE SYNTAX SEQUENCE OF ConnRTCEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table of Connection statistics." ::= { realTimeCountersGroup 4 } connRTCEntry OBJECT-TYPE SYNTAX ConnRTCEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Connection statistics table." INDEX { connRTCSlot, connRTCChannel, connRTCDLCI } ::= { connRTCTable 1 } ConnRTCEntry ::= SEQUENCE { -- -- All of the Counters in this table can be very time-expensive -- to retrieve, taking as much as 10 seconds each. -- Manger timeout values should be adjusted accordingly, and -- Get-Next walks through this portion of the table should be -- avoided. -- connRTCSlot INTEGER, connRTCChannel INTEGER, connRTCDLCI INTEGER, connRTCRcvdFrames Counter, connRTCRcvdFramesDiscarded Counter, connRTCXmitFrames Counter, connRTCXmitFramesDiscarded Counter, connRTCRcvdPkts Counter, connRTCRcvdPktsDiscarded Counter, connRTCXmitPkts Counter, connRTCXmitPktsProjected Counter, connRTCXmitPktsSupervisory Counter, connRTCRcvdBytes Counter, connRTCRcvdBytesDiscarded Counter, connRTCXmitBytes Counter, connRTCXmitBytesDiscarded Counter, connRTCSecondsV25ModemOn Counter, connRTCSecondsDsiEnabled Counter, connRTCSecondsOffHook Counter, connRTCSecondsInService Counter, connRTCXmitFramesWithFECN Counter, connRTCXmitFramesWithBECN Counter, connRTCRxSupervisoryPkts Counter, connRTCCongestedMinuites Counter, connRTCFramesRxWithDE Counter, connRTCFramesTxWithDE Counter, connRTCFramesDiscardedWithDE Counter, connRTCBytesRxWithDE Counter, connRTCFramesRxExcessCir Counter, connRTCBytesRxExcessCir Counter, connRTCLine INTEGER } connRTCSlot OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Local Slot Number." ::= { connRTCEntry 1 } connRTCChannel OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Local Channel Number. These are numbered starting at 1." ::= { connRTCEntry 2 } connRTCDLCI OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Local DLCI Number." ::= { connRTCEntry 3 } connRTCRcvdFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames received from the FRP port associated with the connection. This statistic is valid for Frame Relay Connections only." ::= { connRTCEntry 4 } connRTCRcvdFramesDiscarded OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames received from the FRP port which are associated with the connection, but were discarded before being transmitted onto the Muxbus due to the age of the frame in the IPX system or the lack of buffer space. This statistic is valid for Frame Relay Connections only." ::= { connRTCEntry 5 } connRTCXmitFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames transmitted out the FRP port which were received from the other endpoint of the connection. This statistic is valid for Frame Relay connections only." ::= { connRTCEntry 6 } connRTCXmitFramesDiscarded OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames to be transmitted out the FRP port which were received from the other endpoint of the connection, but were discarded due to the age of the frame in the IPX system, a CRC error, or lack of buffer space. This statistic is valid for Frame Relay Connections only." ::= { connRTCEntry 7 } connRTCRcvdPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets received from the Muxbus by the FRP port associated with the connection endpoint. This statistic is valid for Frame Relay Connections only." ::= { connRTCEntry 8 } connRTCRcvdPktsDiscarded OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets received from the Muxbus at the FRP port associated with the connection endpoint, but were discarded before being assembled into frames and transmitted on the FRP port. This statistic is valid for Frame Relay Connections only." ::= { connRTCEntry 9 } connRTCXmitPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets transmitted from one connection endpoint onto the Muxbus towards the other connection endpoint. This statistic is valid for all types of inter-node connections, and for CDP Data, FRP, LDP and SDP terminated DAX connections." ::= { connRTCEntry 10 } connRTCXmitPktsProjected OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The estimated number of packets which would be used if DSI or DFM were enabled for the connection. This statistic is valid for inter-node voice connections and with all types of data connections. It is not valid for DAX voice connections or Frame Relay connections." ::= { connRTCEntry 11 } connRTCXmitPktsSupervisory OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of supervisory packets transmitted from one connection endpoint to another. Supervisory packets reflect signaling bit transitions for voice connections, and EIA lead transitions for data channels. This statistic is valid on all inter-node 'a', 'c', and 'v' voice connections, all inter- node data connections, all 'd' type voice connection endpoints which are supported by CIP or CDP cards, and all DAX data conn- sections. This statistic is not valid for Frame Relay connections." ::= { connRTCEntry 12 } connRTCRcvdBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frame bytes received from the FRP port associated with the connection endpoint. This statistic is valid for Frame Relay connections only." ::= { connRTCEntry 13 } connRTCRcvdBytesDiscarded OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frame bytes received from the FRP port associated with the connection endpoint, but were discarded due to the age of the frame in the IPX system or the lack of buffer space before being transmitted onto the Muxbus. This statistic is valid for Frame Relay connections only." ::= { connRTCEntry 14 } connRTCXmitBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frame bytes to be received from the Muxbus from the remote end of the connection, which were actually transmitted out the FRP port as frames. This statistic is valid for Frame Relay connections only." ::= { connRTCEntry 15 } connRTCXmitBytesDiscarded OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frame bytes to be received from the Muxbus from the remote end of the connection, but were discarded due to the age of the frame in the IPX system, a CRC error, or lack of buffer space. This statistic is valid for Frame Relay connections only." ::= { connRTCEntry 16 } connRTCSecondsV25ModemOn OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of seconds the V.25 modem has been detected and a connection upgraded from ADPCM to PCM. The status of the V.25 modem detect is checked every 3 seconds, so the granularity of the data which makes up this statistic is 3 seconds. This statistic is valid for inter- node type 'a', 'c' and 'v' voice connections only." ::= { connRTCEntry 17 } connRTCSecondsDsiEnabled OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of seconds that a connection has been performing Digital Speech Interpolation (DSI). The status of DSI is checked every 3 seconds, so the granularity of the data which makes up this statistic is 3 seconds. This statistic is valid for inter-node type 'c' and 'v' voice connections only." ::= { connRTCEntry 18 } connRTCSecondsOffHook OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of seconds that a voice connection has been off-hook. The on-hook state is determined by the signaling bits, as defined by the 'cnfchtp' command. A connection which is not on-hook is treated as off-hook for this statistic. The status of the off-hook condition is checked every 3 seconds, so the granularity of the data which makes up this statistic is 3 seconds. This statistic is valid for all 'a', 'c' and 'v' voice connections, and for 'd' type voice connection endpoints supported by CIP or CDP cards." ::= { connRTCEntry 19 } connRTCSecondsInService OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of seconds that a connection has been in service. A connection is considered to be in service if its end points are not in alarm, that cards required to support the connection are present, and the connection is routed." ::= { connRTCEntry 20 } connRTCXmitFramesWithFECN OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames transmitted out the FRP port with the FECN bit set. This statistic is valid for Frame Relay connections only." ::= { connRTCEntry 21 } connRTCXmitFramesWithBECN OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames transmitted out the FRP port with the BECN bit set. This statistic is valid for Frame Relay connections only." ::= { connRTCEntry 22 } connRTCRxSupervisoryPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of supervisory packets received." ::= { connRTCEntry 23 } connRTCCongestedMinuites OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of minutes in which 50%or more frames are tagged FECN by the FRP." ::= { connRTCEntry 24 } connRTCFramesRxWithDE OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames received from the FRP with the DE bit set." ::= { connRTCEntry 25 } connRTCFramesTxWithDE OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames transmitted from the FRP with the DE bit set. " ::= { connRTCEntry 26 } connRTCFramesDiscardedWithDE OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames received from the local frame relay port with their DE bit set which are discarded before being transmitted onto the Muxbus." ::= { connRTCEntry 27 } connRTCBytesRxWithDE OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of bytes received from the FRP for frames with the DE bit set." ::= { connRTCEntry 28 } connRTCFramesRxExcessCir OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames received in excess of CIR." ::= { connRTCEntry 29 } connRTCBytesRxExcessCir OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of bytes received in excess of CIR." ::= { connRTCEntry 30 } connRTCFramesTxExcessCir OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames transmitted in excess of CIR." ::= { connRTCEntry 31 } connRTCBytesTxExcessCir OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of bytes transmitted in excess of CIR." ::= { connRTCEntry 32 } connRTCLine OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Line Number, for IPX it is always 0." ::= { connRTCEntry 33 } -- -- Trunk Real Time Counter Table -- valid only for SV Plus release ???? trunkRTCTable OBJECT-TYPE SYNTAX SEQUENCE OF TrunkRTCEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table of Trunk Line statistics." ::= { realTimeCountersGroup 5 } trunkRTCEntry OBJECT-TYPE SYNTAX TrunkRTCEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Trunk Line statistics table. Each row may be sparse." INDEX { trunkRTCLocalSlot, trunkRTCLocalPort } ::= { trunkRTCTable 1 } TrunkRTCEntry ::= SEQUENCE { -- -- All of the Counters in this table can be very time-expensive -- to retrieve, taking as much as 10 seconds each. -- Manger timeout values should be adjusted accordingly, and -- Get-Next walks through this portion of the table should be -- avoided. -- trunkRTCLocalSlot INTEGER, trunkRTCLocalPort INTEGER, trunkRTCBipolarViolations Counter, trunkRTCFrameSlips Counter, trunkRTCOutOfFrames Counter, trunkRTCLossOfSignal Counter, trunkRTCFrameBitErrors Counter, trunkRTCCrcErrors Counter, trunkRTCPktOutOfFrames Counter, trunkRTCPktCrcErrors Counter, trunkRTCBadClockErrors Counter, trunkRTCVoicePktsDropped Counter, trunkRTCTimeStampedPktsDropped Counter, trunkRTCNonTimeStampedPktsDropped Counter, trunkRTCHighPriorityPktsDropped Counter, trunkRTCBurstyDataPktsDropped Counter, trunkRTCMulticastPktsDropped Counter, trunkRTCVoicePktsXmitted Counter, trunkRTCTimeStampedPktsXmitted Counter, trunkRTCNonTimeStampedPktsXmitted Counter, trunkRTCHighPriorityPktsXmitted Counter, trunkRTCBurstyDataPktsXmitted Counter, trunkRTCMulticastPktsXmitted Counter, trunkRTCPktsXmitted Counter, trunkRTCTxBurstyDataAClpPktsDropped Counter, trunkRTCTxBurstyDataBClpPktsDropped Counter, trunkRTCBurstyDataAEfcnPktsTx2Line Counter, trunkRTCBurstyDataBEfcnPktsTx2Line Counter, trunkRTCBurstyDataAClpPktsTx2Line Counter, trunkRTCBurstyDataBClpPktsTx2Line Counter, trunkRTCAtmCellHeaderHecErrors Counter, trunkRTCTxVoiceCellsDropped Counter, trunkRTCTxTimeStampCellsDropped Counter, trunkRTCTxNonTStampCellsDropped Counter, trunkRTCTxHighPriorityCellsDropped Counter, trunkRTCTxBurstyDataACellsDropped Counter, trunkRTCTxBurstyDataBCellsDropped Counter, trunkRTCVoiceCellsTx2Line Counter, trunkRTCTimeStampCellsTx2Line Counter, trunkRTCNonTimeStampCellsTx2Line Counter, trunkRTCHighPriorityCellsTx2Line Counter, trunkRTCBurstyDataACellsTx2Line Counter, trunkRTCBurstyDataBCellsTx2Line Counter, trunkRTCTotalCellsTx2Line Counter, trunkRTCTxBurstyDataAClpCellsDropped Counter, trunkRTCTxBurstyDataBClpCellsDropped Counter, trunkRTCBurstyDataAEfcnCellsTx2Line Counter, trunkRTCBurstyDataBEfcnCellsTx2Line Counter, trunkRTCPlcpOutOfFrames Counter } trunkRTCLocalSlot OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Local Slot Number. These are numbered starting at 1" ::= { trunkRTCEntry 1 } trunkRTCLocalPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Local Port Number. These are numbered starting at 1." ::= { trunkRTCEntry 2 } trunkRTCBipolarViolations OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The signal level for a '1' bit should alternate between a positive and a negative signal. If two positive or two negative signals are received in a row, a bipolar violation has occurred." ::= { trunkRTCEntry 4 } trunkRTCFrameSlips OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frame slips which have occurred on the receive side of the line. This statistic is valid for TXR lines only. NTC cards do not support this statistic." ::= { trunkRTCEntry 5 } trunkRTCOutOfFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of 0 -> 1 transitions of the out of frame condition as detected by the hardware. This statistic is valid for T1 and E1 lines only." ::= { trunkRTCEntry 6 } trunkRTCLossOfSignal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of 0 -> 1 transitions of the loss of signal condition as detected by the hardware. This statistic is valid for NTC lines only." ::= { trunkRTCEntry 7 } trunkRTCFrameBitErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frame alignment signal errors which have been detected on this line. This statistic is valid only on lines supported by NTC cards. TXR and Sub-rate lines do not support this statistic. This statistic is also not supported by NTC-T1 in ESF framing mode." ::= { trunkRTCEntry 8 } trunkRTCCrcErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of CRC errors detected on the line. This statistic is valid only on lines supported by NTC cards. TXR cards and Sub- rate lines do not support this statistic. This statistic is also not supported by NTC- T1 in D4 framing mode." ::= { trunkRTCEntry 9 } trunkRTCPktOutOfFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets out of frames on this line. This statistic is only valid on lines supported by NTC cards. TXR cards do not support this statistic." ::= { trunkRTCEntry 10 } trunkRTCPktCrcErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets received with detected CRC errors in the packet headers." ::= { trunkRTCEntry 11 } trunkRTCBadClockErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of 0 -> 1 transitions of the loss of clock condition as detected by the hardware. This statistic is valid on NTC Sub- rate lines only. T1 and E1 lines do not support this statistic." ::= { trunkRTCEntry 12 } trunkRTCVoicePktsDropped OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of voice packets dropped on a line." ::= { trunkRTCEntry 13 } trunkRTCTimeStampedPktsDropped OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of time stamped data packets dropped on the line." ::= { trunkRTCEntry 14 } trunkRTCNonTimeStampedPktsDropped OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of non-time stamped data packets dropped on the line." ::= { trunkRTCEntry 15 } trunkRTCHighPriorityPktsDropped OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of high priority (PCC) packets dropped on the line." ::= { trunkRTCEntry 16 } trunkRTCBurstyDataPktsDropped OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of bursty data packets dropped on the line." ::= { trunkRTCEntry 17 } trunkRTCMulticastPktsDropped OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Multicast packets dropped on the line." ::= { trunkRTCEntry 18 } trunkRTCVoicePktsXmitted OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of voice packets transmitted onto the line." ::= { trunkRTCEntry 19 } trunkRTCTimeStampedPktsXmitted OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of time stamped packets transmitted onto the line." ::= { trunkRTCEntry 20 } trunkRTCNonTimeStampedPktsXmitted OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of non-time stamped packets transmitted onto the line." ::= { trunkRTCEntry 21 } trunkRTCHighPriorityPktsXmitted OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of high priority packets transmitted onto the line." ::= { trunkRTCEntry 22 } trunkRTCBurstyDataPktsXmitted OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of bursty data packets transmitted onto the line." ::= { trunkRTCEntry 23 } trunkRTCMulticastPktsXmitted OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Multicast packets transmitted onto the line." ::= { trunkRTCEntry 24 } trunkRTCPktsXmitted OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of packets transmitted onto the line." ::= { trunkRTCEntry 25 } trunkRTCTxBurstyDataAClpPktsDropped OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets with the CLP bit set that are dropped from the bursty data A queue." ::= { trunkRTCEntry 26 } trunkRTCTxBurstyDataBClpPktsDropped OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets with the CLP bit set that are dropped from the bursty data B queue." ::= { trunkRTCEntry 27 } trunkRTCBurstyDataAEfcnPktsTx2Line OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets with the EFCN bit set which have been transmitted onto the line from the bursty data A queue." ::= { trunkRTCEntry 28 } trunkRTCBurstyDataBEfcnPktsTx2Line OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets with the EFCN bit set which have been transmitted onto the line from the bursty data B queue." ::= { trunkRTCEntry 29 } trunkRTCBurstyDataAClpPktsTx2Line OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets with the CLP bit set which have been transmitted onto the line from the bursty data A queue." ::= { trunkRTCEntry 30 } trunkRTCBurstyDataBClpPktsTx2Line OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets with the CLP bit set which have been transmitted onto the line from the bursty data B queue." ::= { trunkRTCEntry 31 } trunkRTCAtmCellHeaderHecErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of ATM cell headers with HEC errors." ::= { trunkRTCEntry 32 } trunkRTCTxVoiceCellsDropped OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of transmit voice cells dropped." ::= { trunkRTCEntry 33 } trunkRTCTxTimeStampCellsDropped OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of transmit time stamped cells dropped." ::= { trunkRTCEntry 34 } trunkRTCTxNonTStampCellsDropped OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of transmit non time stamped cells dropped." ::= { trunkRTCEntry 35 } trunkRTCTxHighPriorityCellsDropped OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of transmit high priority cells dropped." ::= { trunkRTCEntry 36 } trunkRTCTxBurstyDataACellsDropped OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of cells dropped from the bursty data A queue." ::= { trunkRTCEntry 37 } trunkRTCTxBurstyDataBCellsDropped OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of cells dropped from the bursty data B queue." ::= { trunkRTCEntry 38 } trunkRTCVoiceCellsTx2Line OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of voice cells transmitted onto the line." ::= { trunkRTCEntry 39 } trunkRTCTimeStampCellsTx2Line OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of time stamped cells transmitted onto the line." ::= { trunkRTCEntry 40 } trunkRTCNonTimeStampCellsTx2Line OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of non time stamped cells transmitted onto the line." ::= { trunkRTCEntry 41 } trunkRTCHighPriorityCellsTx2Line OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of high priority cells transmitted onto the line." ::= { trunkRTCEntry 42 } trunkRTCBurstyDataACellsTx2Line OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of cells which have been transmitted onto the line from the bursty data A queue." ::= { trunkRTCEntry 43 } trunkRTCBurstyDataBCellsTx2Line OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of cells which have been transmitted onto the line from the bursty data B queue." ::= { trunkRTCEntry 44 } trunkRTCTotalCellsTx2Line OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of cells transmitted onto the line." ::= { trunkRTCEntry 45 } trunkRTCTxBurstyDataAClpCellsDropped OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of cells with the CLP bit set which have been dropped from the bursty data A queue." ::= { trunkRTCEntry 46 } trunkRTCTxBurstyDataBClpCellsDropped OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of cells with the CLP bit set which have been dropped from the bursty data B queue." ::= { trunkRTCEntry 47 } trunkRTCBurstyDataAEfcnCellsTx2Line OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of cells with the EFCN bit set which have been transmitted onto the line from the bursty data A queue." ::= { trunkRTCEntry 48 } trunkRTCBurstyDataBEfcnCellsTx2Line OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of cells with the EFCN bit set which have been transmitted onto the line from the bursty data B queue." ::= { trunkRTCEntry 49 } trunkRTCPlcpOutOfFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of out of frame conditions." ::= { trunkRTCEntry 50 } -- --------------------------------------------------------- -- Trap Config Table -- --------------------------------------------------------- trapConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF TrapConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table has the information about the manager receiving traps" ::= { trapsConfig 1 } trapConfigEntry OBJECT-TYPE SYNTAX TrapConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry of the manager table." INDEX { managerIPaddress } ::= { trapConfigTable 1 } TrapConfigEntry ::= SEQUENCE { managerIPaddress IpAddress, managerPortNumber INTEGER, managerRowStatus INTEGER, readingTrapFlag INTEGER, nextTrapSeqNum INTEGER } managerIPaddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { trapConfigEntry 1 } managerPortNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { trapConfigEntry 2 } managerRowStatus OBJECT-TYPE SYNTAX INTEGER { addRow (1), delRow (2) } ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { trapConfigEntry 3 } readingTrapFlag OBJECT-TYPE SYNTAX INTEGER { false (1), true (2) } ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { trapConfigEntry 4 } nextTrapSeqNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { trapConfigEntry 5 } managerNumOfValidEntries OBJECT-TYPE SYNTAX INTEGER(1..8) ACCESS read-only STATUS mandatory DESCRIPTION "The number of managers in the table that are programmed to receive traps" ::= { trapsConfig 2 } lastSequenceNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The Sequence Number of the last trap generated on the SNMP Proxy" ::= { trapsConfig 3 } ----------------------------------------------------------------------- -- RTM Group -- ----------------------------------------------------------------------- trapUploadTable OBJECT-TYPE SYNTAX SEQUENCE OF TrapUploadEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table has the information about the manager receiving traps" ::= { trapsConfig 4 } trapUploadEntry OBJECT-TYPE SYNTAX TrapUploadEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry of the manager table." INDEX { mgrIpAddress } ::= { trapUploadTable 1 } TrapUploadEntry ::= SEQUENCE { mgrIpAddress IpAddress, trapSequenceNum INTEGER, trapPduString OCTET STRING, endOfQueueFlag INTEGER } mgrIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { trapUploadEntry 1 } trapSequenceNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The sequence number associated with the trap" ::= { trapUploadEntry 2 } trapPduString OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The sequence number associated with the trap" ::= { trapUploadEntry 3 } endOfQueueFlag OBJECT-TYPE SYNTAX INTEGER { false(1), true(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The sequence number associated with the trap" ::= { trapUploadEntry 4 } -- -- control Group contains attributes associated with controlling -- logGroup as a whole. This group is mandatory databaseSampleFreq OBJECT-TYPE SYNTAX INTEGER (5..86400) ACCESS read-write STATUS mandatory DESCRIPTION "The desired rate (in seconds) at which the database should be queried for new log records that match any of the filter criteria from the Event Filter Table. The agent may optionally poll more or less frequently then specified by this variable. The value of this variable is only a suggestion to the agent." DEFVAL { 60 } ::= { controlGroup 1 } ----------------------------------------------------------------------- -- Log Group. ----------------------------------------------------------------------- currentMaxLogIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The current max value of logIndex. This value may change with time." ::= { logGroup 1 } ----------------------------------------------------------------------- -- Maint Log Table ----------------------------------------------------------------------- maintLogTable OBJECT-TYPE SYNTAX SEQUENCE OF MaintLogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table of log entries." ::= { logGroup 2 } maintLogEntry OBJECT-TYPE SYNTAX MaintLogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the log table." INDEX { logIndex } ::= { maintLogTable 1 } MaintLogEntry ::= SEQUENCE { logIndex INTEGER, logNetwork DisplayString, logNodeName DisplayString, logGmtDate DisplayString, logSeverity Severity, logMsg DisplayString } logIndex OBJECT-TYPE SYNTAX INTEGER (1..1073741824) ACCESS read-only STATUS mandatory DESCRIPTION "Unique index of the Log record." ::= { maintLogEntry 1 } logNetwork OBJECT-TYPE SYNTAX DisplayString (SIZE (0..10)) ACCESS read-only STATUS mandatory DESCRIPTION "Name of the network for which this log entry was generated." ::= { maintLogEntry 2 } logNodeName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..10)) ACCESS read-only STATUS mandatory DESCRIPTION "Name of the IPX node for this log entry was generated." ::= { maintLogEntry 3 } logGmtDate OBJECT-TYPE SYNTAX DisplayString (SIZE (19)) ACCESS read-only STATUS mandatory DESCRIPTION "ASCII formatted string indicating the GMT date and time for this log record in the format (yyyy-mm-dd hh:mm:ss). This is the time reported by the IPX which generated the event." ::= { maintLogEntry 4 } logSeverity OBJECT-TYPE SYNTAX Severity ACCESS read-only STATUS mandatory DESCRIPTION "The severity of this log record." ::= { maintLogEntry 5 } logMsg OBJECT-TYPE SYNTAX DisplayString (SIZE (0..256)) ACCESS read-only STATUS mandatory DESCRIPTION "An ASCII message associated with this log record." ::= { maintLogEntry 6 } ----------------------------------------------------------------------- -- Event Filtering Table ----------------------------------------------------------------------- -- -- In order for a manager to create a row of this table, a -- single SET request should be sent with all the variables -- for every column specified. -- -- In order for a manager to delete a row of this table, a -- single SET request should be sent to change the -- eventFilterStatus column from 'active' to 'invalid'. -- -- For a new log record to be forwarded as a TRAP the following -- must be true: -- -- eventFilterStatus must be 'active'. -- -- eventFilterSeverity must exactly match the logSeverity -- of the log record. -- -- eventFilterSubstring must contain a string that is -- found in the logMsg variable of the -- log record. -- -- To request all events of all severity levels, set both the -- eventFilterSeverity and eventFilterSubstring elements to -- be zero-length strings. -- eventFilterTable OBJECT-TYPE SYNTAX SEQUENCE OF EventFilterEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table of Event Filters." ::= { logGroup 3 } eventFilterEntry OBJECT-TYPE SYNTAX EventFilterEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Event Filter table. Each entry in this table describes a set of log entry criteria, and entries in the log that match these criteria will be forwarded as SNMP TRAPS." INDEX { eventFilterIndex } ::= { eventFilterTable 1 } EventFilterEntry ::= SEQUENCE { eventFilterIndex INTEGER, eventFilterStatus INTEGER, eventFilterSeverity Severity, eventFilterSubstring DisplayString } eventFilterIndex OBJECT-TYPE SYNTAX INTEGER ( 1 .. 2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The unique index for each entry of this table. This entry can only be written with the first SET command to create a new row of this table." ::= { eventFilterEntry 1 } eventFilterStatus OBJECT-TYPE SYNTAX INTEGER { invalid (1), active (2) } ACCESS read-write STATUS mandatory DESCRIPTION "'active' indicates that this row of the table is currently generating filtered TRAPs. When in this state, any entry added to the log table with logSeverity matching eventFilterSeverity and logMsg containing the eventFilterSubstring text, this information will be forwarded as a TRAP. 'invalid' indicates that this row of the table is no longer generating filtered TRAPs. A conforming agent may either leave the row with the 'invalid' value in the table, or may delete the row from the table." DEFVAL { active } ::= { eventFilterEntry 2 } eventFilterSeverity OBJECT-TYPE SYNTAX Severity ACCESS read-write STATUS mandatory DESCRIPTION "The eventFilterSeverity specifies the severity of log records to be forwarded on as SNMP TRAPS by this event filter entry. The value of eventFilterSeverity must exactly match the value of logSeverity for there to be a chance that a new log record will be forwarded as a TRAP. An eventFilterSeverity of length 0 matches all severity levels." DEFVAL { ''h } ::= { eventFilterEntry 3 } eventFilterSubstring OBJECT-TYPE SYNTAX DisplayString (SIZE (0..256)) ACCESS read-write STATUS mandatory DESCRIPTION "The eventFilterSubstring variable specifies an ASCII substring that must appear in the logMsg field of a log record in order for there to be a chance that for the log record to forwarded as a TRAP. If this variable contains a zero length string, the substring comparison will always SUCCEED for this event filter entry." DEFVAL { ''h } ::= { eventFilterEntry 4 } -- -- maintLog Table Filter Group -- -- This group is optional and may be used to support filtering -- GetNext requests when retrieving elements from the -- mainLogTable. If the group is supported then all attributes -- in the group are mandatory. -- -- maintLogFilterGroup OBJECT IDENTIFIER ::= { logGroup 4 } -- When applying the maintLogFilterGroup attributes during an -- SNMP Operation, the order is important. The attributes will -- be applied in the following order: -- maintLogFilterTimeMin -- maintLogFilterTimeMax -- maintLogFilterNetworkName -- maintLogFilterNodeName -- maintLogFilterSeverity -- maintLogFilterWindow -- maintLogFilterTimeMin OBJECT-TYPE SYNTAX DisplayString(SIZE(0..22)) ACCESS read-write STATUS mandatory DESCRIPTION "When maintLogFilterTimeMin has a value other than a 0 length string, the value is used as a minimum value for maintLogFilterGmtDate to qualify entries in the maintLogTable. The string is formatted as yyyy-mm-dd hh:mm:ss" DEFVAL { ''h } ::= { maintLogFilterGroup 1 } maintLogFilterTimeMax OBJECT-TYPE SYNTAX DisplayString(SIZE(0..22)) ACCESS read-write STATUS mandatory DESCRIPTION "When maintLogFilterTimeMax has a value other than a 0 length string, the value is used as a maximum value for maintLogFilterGmtDate to qualify entries in the maintLogTable. The string is formatted as yyyy-mm-dd hh:mm:ss" DEFVAL { ''h } ::= { maintLogFilterGroup 2 } maintLogFilterWindow OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "When maintLogFilterWindow has a value other than 0, the value is used to qualify entries in the maintLogTable. This attribute has the effect of limiting the view in the maintLogTable to the number specified by the value of this attribute. If after applying the other maintLogFilter attributes, the remaining set exceeds the value of maintLogFilterWindow then, the set of entries which can be viewed is limited to the top N based on the logIndex value." DEFVAL { 30 } ::= { maintLogFilterGroup 3 } maintLogFilterNetworkNam OBJECT-TYPE SYNTAX DisplayString (SIZE (0..10)) ACCESS read-write STATUS mandatory DESCRIPTION "When maintLogFilterNetworkName has a value other than a 0 length string, then the value of this attribute is used to qualify entries in the maintLogTable. This value must match logNetwork exactly to pass the filter." DEFVAL { ''h } ::= { maintLogFilterGroup 4 } maintLogFilterNodeName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..10)) ACCESS read-write STATUS mandatory DESCRIPTION "When maintLogFilterNodeName has a value other than a 0 length string, then the value of this attribute is used to qualify entries in the maintLogTable. This value must match logNodeName exactly to pass the filter." DEFVAL { ''h } ::= { maintLogFilterGroup 5 } maintLogFilterSeverity OBJECT-TYPE SYNTAX Severity ACCESS read-write STATUS mandatory DESCRIPTION "When maintLogFilterSeverity has a value other than a 0 length string, then the value is used to qualify entries in the maintLogTable. The value must match the logSeverity exactly to pass the filter." DEFVAL { ''h } ::= { maintLogFilterGroup 6 } ----------------------------------------------------------------------- -- Network Group ----------------------------------------------------------------------- ----------------------------------------------------------------------- -- Network Table ----------------------------------------------------------------------- networkTable OBJECT-TYPE SYNTAX SEQUENCE OF NetworkEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table of Networks." ::= { networkGroup 1 } networkEntry OBJECT-TYPE SYNTAX NetworkEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Network table." INDEX { networkName } ::= { networkTable 1 } NetworkEntry ::= SEQUENCE { networkName DisplayString, networkId INTEGER, networkIpxId INTEGER } networkName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..10)) ACCESS read-only STATUS mandatory DESCRIPTION "The name of the network as assigned by the StrataView User." ::= { networkEntry 1 } networkId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The unique ID of the network as assigned by the StrataView system." ::= { networkEntry 2 } networkIpxId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The IPX network ID." ::= { networkEntry 3 } ----------------------------------------------------------------------- -- Node Group ----------------------------------------------------------------------- ----------------------------------------------------------------------- -- Node Table ----------------------------------------------------------------------- nodeTable OBJECT-TYPE SYNTAX SEQUENCE OF NodeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table of Nodes." ::= { nodeGroup 1 } nodeEntry OBJECT-TYPE SYNTAX NodeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Node table." INDEX { nodeNetworkName, nodeName } ::= { nodeTable 1 } NodeEntry ::= SEQUENCE { nodeNetworkName DisplayString, nodeName DisplayString } nodeNetworkName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..10)) ACCESS read-only STATUS mandatory DESCRIPTION "The name of the network to which this node is attached." ::= { nodeEntry 1 } nodeName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..10)) ACCESS read-only STATUS mandatory DESCRIPTION "IPX node name." ::= { nodeEntry 2 } -- -- Trap Definitions -- trunkStatusAlarm TRAP-TYPE ENTERPRISE svnode VARIABLES { lastSequenceNumber, nodeGrpName, nodeGrpNetName, trunkStatus } DESCRIPTION "This trap is generated whenever an ObjectAlarm Status message is received containing the trunk status." ::= 0 cirLineStatusAlarm TRAP-TYPE ENTERPRISE svnode VARIABLES { lastSequenceNumber, nodeGrpName, nodeGrpNetName, cirLineStatus } DESCRIPTION "This trap is generated whenever an ObjectAlarm Status message is received containing the cirLineStatus." ::= 1 frpStatusAlarm TRAP-TYPE ENTERPRISE svnode VARIABLES { lastSequenceNumber, nodeGrpName, nodeGrpNetName, frpStatus } DESCRIPTION "This trap is generated whenever an ObjectAlarm Status message is received containing the frpStatus." ::= 2 connStatusAlarm TRAP-TYPE ENTERPRISE svnode VARIABLES { lastSequenceNumber, nodeGrpName, nodeGrpNetName, connStatus, connABitStatus } DESCRIPTION "This trap is generated whenever an ObjectAlarm Status message is received containing the connStatus." ::= 3 filteredLogRecord TRAP-TYPE ENTERPRISE svplus VARIABLES { lastSequenceNumber, logIndex, logNetwork, logNodeName, logGmtDate, logSeverity, logMsg } DESCRIPTION "The 'filteredLogRecord' trap is generated by the StrataView system whenever an entry in the eventFilterTable matches a log record that is added to the StrataView database." ::= 0 END