-- ================================================================== -- LANCAST PROPRIETARY PHYSICAL ENTITIES MIB -- ================================================================== -- ================================================================= LC-PHYSICAL-ENTITIES-MIB -- NOTES: -- -- 1) The mib compiler renames a MIB Module name by adding -- an extension of -A. This results in the following error: -- The module identity for "LC-PHYSICAL-ENTITIES-MIB-A" conflicts with -- the one for "LC-PHYSICAL-ENTITIES-MIB" which prevents the generation -- of an output file. -- -- This is resolved by commenting out the following in the control file: -- a) the IMPORT statement of MODULE-IDENTITY -- b) the full MODULE-IDENTITY clause AND replace it with: -- -- physicalEntities OBJECT IDENTIFIER ::= { lancastMibModulesA 2 } -- -- You will get the following warning but it can be ignored. -- "Warning: A MIB module must start with exactly one invocation of -- the MODULE-IDENTITY macro immediately following an optional IMPORTS -- clause." -- DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32 FROM SNMPv2-SMI DisplayString FROM SNMPv2-TC lancastMibModulesA, lancastTraps FROM LANCAST-MIB; -- ======================================================================= -- MODULE IDENTITY & REVISION HISTORY -- ======================================================================= physicalEntities MODULE-IDENTITY LAST-UPDATED "9903031200Z" ORGANIZATION "Lancast Inc" CONTACT-INFO "Contact: Customer Service Tel: 1-877-526-2278 ext 136 Fax: 1-603-594-2887 Web: info@lancast.com" DESCRIPTION "This is the enterprise MIB definition file for the Physical Entities of Lancast Managed products. Copyright 1999 Lancast Inc." REVISION "9903031200Z" DESCRIPTION "REV 1.0 original Draft" ::= { lancastMibModulesA 2 } -- ====================================================================== -- PHYSICAL ENTITIES BRANCH OID: 1.3.6.1.4.1.2745.1.2 -- ====================================================================== -- stackGroup OBJECT IDENTIFIER ::= { physicalEntities 1 } chassisGroup OBJECT IDENTIFIER ::= { physicalEntities 2 } backPlaneGroup OBJECT IDENTIFIER ::= { physicalEntities 3 } powerSupplyGroup OBJECT IDENTIFIER ::= { physicalEntities 4 } modulesGroup OBJECT IDENTIFIER ::= { physicalEntities 5 } ePortGroup OBJECT IDENTIFIER ::= { physicalEntities 6 } serialPortGroup OBJECT IDENTIFIER ::= { physicalEntities 7 } -- ======================================================================= -- The Chassis Group -- chassisTable OID: 1.3.6.1.4.1.2745.2.2.1 -- ======================================================================= chassisTable OBJECT-TYPE SYNTAX SEQUENCE OF ChassisTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of relevent information pertaining to each chassis contained within this system." ::= {chassisGroup 1 } chassisTableEntry OBJECT-TYPE SYNTAX ChassisTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table, containing relevant information about a specific chassis contained within this system." INDEX { chassisEntityIndex } ::= {chassisTable 1} ChassisTableEntry ::= SEQUENCE { chassisEntityIndex Integer32, chassisDescription DisplayString, chassisPartNumber DisplayString, chassisNumSlots Integer32, chassisCurrentTemp Integer32, chassisMaxTemp Integer32, chassisReset INTEGER, lastEntityResetReason INTEGER, lastEntityResetIndex Integer32, lastEntityResetTime DisplayString, lastEntityResetType INTEGER } chassisEntityIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value, the entPhysicalIndex from the entity MIB, which identifies this chassis." ::= { chassisTableEntry 1 } chassisDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (1..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "A textual string describing a chassis contained within this system." ::= { chassisTableEntry 2 } chassisPartNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (1..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "A textual string of the part number assigned to this chassis." ::= { chassisTableEntry 3 } chassisNumSlots OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of I/O slots that this chassis supports." ::= { chassisTableEntry 4 } chassisCurrentTemp OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The temperature of this chassis measured in Celcius degrees. This object will be contained in the tempStatusChange trap," ::= { chassisTableEntry 5 } chassisMaxTemp OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum temperature for this chassis. If this temperature is exceeded failures may result. This object will be contained in the tempStatusChange Trap," ::= { chassisTableEntry 6 } chassisReset OBJECT-TYPE SYNTAX INTEGER { reset (1), resetable (2), not-resetable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The trigger to reset this chassis. If the design of this chassis does not include this feature then this object will default to not-resetable and no sets to this object will be allowed. If the design does permit a reset then the only valid state that a user can set this object to is is reset. A read of this object will return either resetable or not-resetable." ::= { chassisTableEntry 7 } lastEntityResetReason OBJECT-TYPE SYNTAX INTEGER { cold-start (1), nms-sw-reset (2), download-reset (3), watch-dog-timeout (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the reason the last reset was applied. This object is included in the entityResetTrap pdu." ::= { chassisTableEntry 8 } lastEntityResetIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the physical entity index, entPhysicalIndex from the entity MIB, of the last entity that was reset. This object is included in the entityResetTrap pdu." ::= { chassisTableEntry 9 } lastEntityResetTime OBJECT-TYPE SYNTAX DisplayString (SIZE (1..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the time the last reset was applied to an entity. This object is included in the entityResetTrap pdu." ::= { chassisTableEntry 10 } lastEntityResetType OBJECT-TYPE SYNTAX INTEGER { chassis (3), module (9), port (10) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the type of entity that was last reset. The values are are a subset from the entity mib entPhysicalClass object." ::= { chassisTableEntry 11 } -- ======================================================================= -- The Backplane Group -- backplaneTable OID: 1.3.6.1.4.1.2745.2.3.1 -- ======================================================================= backPlaneTable OBJECT-TYPE SYNTAX SEQUENCE OF BackPlaneTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of relevent information pertaining to a backplane contained within this system." ::= { backPlaneGroup 1 } backPlaneTableEntry OBJECT-TYPE SYNTAX BackPlaneTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table, containing relevant information about a specific backplane contained within this system." INDEX { backPlaneEntityIndex } ::= { backPlaneTable 1} BackPlaneTableEntry ::= SEQUENCE { backPlaneEntityIndex Integer32, backPlaneDescription DisplayString, backPlanePartNumber DisplayString, backPlaneSerialNumber DisplayString, backPlaneManufactureDate DisplayString, backPlaneHWRevisionNumber DisplayString } backPlaneEntityIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value, the entPhysicalIndex from the entity MIB, that identifies a back plane for which this entry contains information." ::= { backPlaneTableEntry 1 } backPlaneDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (1..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "A textual string describing a backPlane contained within this system." ::= { backPlaneTableEntry 2 } backPlanePartNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (1..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "A textual string of the part number of this back plane." ::= { backPlaneTableEntry 3 } backPlaneSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (1..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "A textual string of the serial number of this back plane." ::= { backPlaneTableEntry 4 } backPlaneManufactureDate OBJECT-TYPE SYNTAX DisplayString (SIZE (1..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "A textual string of the manufacture date of this back plane." ::= { backPlaneTableEntry 5 } backPlaneHWRevisionNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (1..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "A textual string of the hardware revision date of this back plane." ::= { backPlaneTableEntry 6 } -- ======================================================================= -- The Power Supply Group -- powerSupplyTable OID: 1.3.6.1.4.1.2745.2.4.1 -- ======================================================================= powerSupplyTable OBJECT-TYPE SYNTAX SEQUENCE OF PowerSupplyTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of relevent information pertaining to a backplane contained within this system." ::= { powerSupplyGroup 1 } powerSupplyTableEntry OBJECT-TYPE SYNTAX PowerSupplyTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table, containing relevant information about a specific backplane contained within this system." INDEX { powerSupplyEntityIndex } ::= { powerSupplyTable 1} PowerSupplyTableEntry ::= SEQUENCE { powerSupplyEntityIndex Integer32, powerSupplyStatus INTEGER, powerSupplyType INTEGER, powerSupply5vCurrent Integer32, powerSupply5vMin Integer32, powerSupply5vMax Integer32, powerSupplyUnitIdentifier INTEGER } powerSupplyEntityIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value, the entPhysicalIndex from the entity MIB, that identifies a power supply for which this entry contains information." ::= { powerSupplyTableEntry 1 } powerSupplyStatus OBJECT-TYPE SYNTAX INTEGER{ on (1), off (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The on off state of this power supply." ::= { powerSupplyTableEntry 2 } powerSupplyType OBJECT-TYPE SYNTAX INTEGER { ac (1), dc (2), universal (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of this power supply." ::= { powerSupplyTableEntry 3 } powerSupply5vCurrent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The actual voltage level of this 5 volt supply as measured in millivolts." ::= { powerSupplyTableEntry 4 } powerSupply5vMin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum operating voltage level of this 5 volt supply, measured in millivolts." ::= { powerSupplyTableEntry 5 } powerSupply5vMax OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum operating voltage level of this 5 volt supply, measured in millivolts." ::= { powerSupplyTableEntry 6 } powerSupplyUnitIdentifier OBJECT-TYPE SYNTAX INTEGER { ps-A (1), ps-B (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The identifier of this supply." ::= { powerSupplyTableEntry 7 } -- ======================================================================= -- Modules Group Branch OID: 1.3.6.1.4.1.2745.2.5 -- -- Module Table OID: 1.3.6.1.4.1.2745.2.5.1 -- Managment Table OID: 1.3.6.1.4.1.2745.2.5.2 -- Single Twister OID: 1.3.6.1.4.1.2745.2.5.3 -- Dual Twister OID: 1.3.6.1.4.1.2745.2.5.4 -- Redundant Twister OID: 1.3.6.1.4.1.2745.2.5.5 -- -- ======================================================================= moduleTable OBJECT-TYPE SYNTAX SEQUENCE OF ModuleTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of common information relevent to modules within this system." ::= { modulesGroup 1 } moduleTableEntry OBJECT-TYPE SYNTAX ModuleTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the common module information table." INDEX { modEntityIndex } ::= { moduleTable 1 } ModuleTableEntry ::= SEQUENCE { modEntityIndex Integer32, modAdminState INTEGER, modOperStatus INTEGER, modType INTEGER, modDescription DisplayString, modName DisplayString, modPartNumber DisplayString, modSerialNumber DisplayString, modManufactureDate DisplayString, modDiagnosticTestStatus DisplayString, modHWRevisionNumber DisplayString, modNumPorts Integer32, modFirstSlot Integer32, modNumSlotsOccupied Integer32, modReset INTEGER } modEntityIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value, entPhysicalIndex from the entity MIB, that identifies a module for which this entry contains information." ::= { moduleTableEntry 1 } modAdminState OBJECT-TYPE SYNTAX INTEGER { not-applicable (0), up (1), down (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The desired state of up or down of this module. If the design of this module does not include the abiltiy to control this module then this object will default to not-applicable and no sets to this object will be allowed. If the design does permit control then up and down are the valid states that a user can set this object to." ::= { moduleTableEntry 2 } modOperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current operational (up/down) state of this module." ::= { moduleTableEntry 3 } modType OBJECT-TYPE SYNTAX INTEGER { unknown (1), reserved (2), mgmnt (3), singleTwister (4), dualTwister (5), redundantTwister (6), displayModule (7), singleTwister2 (8), fixedPort (9), rateAdapter (10), gigabitTwister (11) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of module resident in this system." ::= { moduleTableEntry 4 } modDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (1..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "A textual description of this type of module." ::= { moduleTableEntry 5 } modName OBJECT-TYPE SYNTAX DisplayString (SIZE (1..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "A user defined name for this module." ::= { moduleTableEntry 6 } modPartNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (1..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "A textual string identifying the part number of this module." ::= { moduleTableEntry 7 } modSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (1..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "A textual string identifying the serieal number of this module." ::= { moduleTableEntry 8 } modManufactureDate OBJECT-TYPE SYNTAX DisplayString (SIZE (1..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "A textual string identifying the date that this module was manufactured." ::= { moduleTableEntry 9 } modDiagnosticTestStatus OBJECT-TYPE SYNTAX DisplayString (SIZE (1..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "A textual string indicating the status of the last diagnostic test performed on this module including the date and time." ::= { moduleTableEntry 10 } modHWRevisionNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (1..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "A textual string identifying the hardware revision number of this module." ::= { moduleTableEntry 11 } modNumPorts OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of ports conntained within this module." ::= { moduleTableEntry 12 } modFirstSlot OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The first slot which is the leftmost slot that this module physically resides in." ::= { moduleTableEntry 13 } modNumSlotsOccupied OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of slots that this module physically occupies." ::= { moduleTableEntry 14 } modReset OBJECT-TYPE SYNTAX INTEGER { reset (1), resetable (2), not-resetable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The trigger to reset this module. If the design of this module does not include this feature then this object will default to not-resetable and no sets to this object will be allowed. If the design does permit a reset then the only valid state that a user can set this object to is is reset. A read of this object will return either resetable or not-resetable." ::= { moduleTableEntry 15 } -- ====================================================================== -- Managment Module Table -- Table OID: 1.3.6.1.4.1.2745.2.5.2 -- ====================================================================== mgmntTable OBJECT-TYPE SYNTAX SEQUENCE OF MgmntTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of information common to management modules within this system." ::= { modulesGroup 2 } mgmntTableEntry OBJECT-TYPE SYNTAX MgmntTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the managment module information table." INDEX { mgmntEntityIndex } ::= { mgmntTable 1 } MgmntTableEntry ::= SEQUENCE { mgmntEntityIndex Integer32, mgmntBootImageName DisplayString, mgmntBootImageVersion DisplayString, mgmntCoreImageName DisplayString, mgmntCoreImageVersion DisplayString, mgmntAppImageName DisplayString, mgmntAppImageVersion DisplayString, mgmntRamMemorySize Integer32, mgmntFlashMemorySize Integer32, mgmntNVRamMemorySize Integer32, mgmnt5vCurrent Integer32, mgmnt5vMin Integer32, mgmnt5vMax Integer32, mgmnt3pt3vCurrent Integer32, mgmnt3pt3vMin Integer32, mgmnt3pt3vMax Integer32, mgmntDiagnosticBootError INTEGER } mgmntEntityIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value, the entPhysicalIndex from the entity MIB, that identifies a managemnt module for which this entry contains information." ::= { mgmntTableEntry 1 } mgmntBootImageName OBJECT-TYPE SYNTAX DisplayString (SIZE (1..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "A textual description of the name of the Boot image." ::= { mgmntTableEntry 2 } mgmntBootImageVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (1..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "A textual description of the version of the Boot image The vesion will include the time and date of the build." ::= { mgmntTableEntry 3 } mgmntCoreImageName OBJECT-TYPE SYNTAX DisplayString (SIZE (1..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "A textual description of the name of the Core image." ::= { mgmntTableEntry 4 } mgmntCoreImageVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (1..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "A textual description of the version of the Core image The vesion will include the time and date of the build." ::= { mgmntTableEntry 5 } mgmntAppImageName OBJECT-TYPE SYNTAX DisplayString (SIZE (1..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "A textual description of the name of the Application (personality) image." ::= { mgmntTableEntry 6 } mgmntAppImageVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (1..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "A textual description of the version of the Application (personality) image. The vesion will include the time and date of the build." ::= { mgmntTableEntry 7 } mgmntRamMemorySize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The size of RAM memory measured in number of bytes." ::= { mgmntTableEntry 8 } mgmntFlashMemorySize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The size of Flash memory measured in number of bytes." ::= { mgmntTableEntry 9 } mgmntNVRamMemorySize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The size of Non Volatile Ram memory measured in number of bytes." ::= { mgmntTableEntry 10 } mgmnt5vCurrent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The actual voltage level of this 3.3 volt input as measured in millivolts." ::= { mgmntTableEntry 11 } mgmnt5vMin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum operating voltage level of this 5 volt input, measured in millivolts." ::= { mgmntTableEntry 12 } mgmnt5vMax OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum operating voltage level of this 5 volt input, measured in millivolts." ::= { mgmntTableEntry 13 } mgmnt3pt3vCurrent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The actual voltage level of this 3.3 volt input as measured in millivolts." ::= { mgmntTableEntry 14 } mgmnt3pt3vMin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum operating voltage level of this 3.3 volt input, measured in millivolts." ::= { mgmntTableEntry 15 } mgmnt3pt3vMax OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum operating voltage level of this 3.3 volt input, measured in millivolts." ::= { mgmntTableEntry 16 } mgmntDiagnosticBootError OBJECT-TYPE SYNTAX INTEGER { on (1), off (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the status of the diagnostic boot tests. An error is indicated by turning the error indicator on the management module is on." ::= { mgmntTableEntry 17 } -- ====================================================================== -- Single Twister Module Table -- Table OID: 1.3.6.1.4.1.2745.2.5.3 -- ====================================================================== singleTwisterTable OBJECT-TYPE SYNTAX SEQUENCE OF SingleTwisterTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of information common to single twister modules." ::= { modulesGroup 3 } singleTwisterTableEntry OBJECT-TYPE SYNTAX SingleTwisterTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the single Twister table of information." INDEX { stwEntityIndex } ::= { singleTwisterTable 1 } SingleTwisterTableEntry ::= SEQUENCE { stwEntityIndex Integer32, stwLinkLossCarryForward INTEGER } stwEntityIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value, the entPhysicalIndex from the entity MIB, that identifies a single twister module for which this entry contains information." ::= { singleTwisterTableEntry 1 } stwLinkLossCarryForward OBJECT-TYPE SYNTAX INTEGER { enable (1), disable (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The ability of an input port to forward the link test pulse to its output port. If disabled the output port will always generate link pulses, regardless of input port link status." ::= { singleTwisterTableEntry 2 } -- ====================================================================== -- Dual Twister Module Table -- Table OID: 1.3.6.1.4.1.2745.2.5.4 -- ====================================================================== dualTwisterTable OBJECT-TYPE SYNTAX SEQUENCE OF DualTwisterTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of information common to dual twister modules." ::= { modulesGroup 4 } dualTwisterTableEntry OBJECT-TYPE SYNTAX DualTwisterTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dual Twister table of information." INDEX { stwEntityIndex } ::= { dualTwisterTable 1 } DualTwisterTableEntry ::= SEQUENCE { dtwEntityIndex Integer32, dtwLinkLossCarryForward INTEGER } dtwEntityIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value, the entPhysicalIndex from the entity MIB, that identifies a dual twister module for which this entry contains information." ::= { dualTwisterTableEntry 1 } dtwLinkLossCarryForward OBJECT-TYPE SYNTAX INTEGER { enable (1), disable (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The ability of an input port to forward the link test pulse to its output port. If disabled the output port will always generate link pulses, regardless of input port link status." ::= { dualTwisterTableEntry 2 } -- ================================================================= -- Redundant Twister Table -- Table OID: 1.3.6.1.4.1.2745.2.5.5 -- ================================================================= redundantTwisterTable OBJECT-TYPE SYNTAX SEQUENCE OF RedundantTwisterTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of information common to redundant twister modules." ::= { modulesGroup 5 } redundantTwisterTableEntry OBJECT-TYPE SYNTAX RedundantTwisterTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table containing redundant twister information." INDEX { rtwEntityIndex } ::= { redundantTwisterTable 1 } RedundantTwisterTableEntry ::= SEQUENCE { rtwEntityIndex Integer32, rtwAutoRestorePrimary INTEGER, rtwLinkLossCarryForward INTEGER, rtwActivePort INTEGER, rtwRedundantTransmission INTEGER, rtwSecondarySwitchOver INTEGER, rtwLinkPulseControl INTEGER, rtwModeControl INTEGER, rtwABSelect INTEGER } rtwEntityIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value, the entPhysicalIndex from the entity MIB, that identifies a redundant twister module for which this entry contains information." ::= { redundantTwisterTableEntry 1 } rtwAutoRestorePrimary OBJECT-TYPE SYNTAX INTEGER { enable (1), disable (2), not-selectable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object controls the ability to perform auto restoration back to the primary circuit if a secondary switchover had previously occurred. When rtwModeControl is selectAB then this object is not selectable and a read of this value will always return not selectable." ::= { redundantTwisterTableEntry 2 } rtwLinkLossCarryForward OBJECT-TYPE SYNTAX INTEGER { enable (1), disable (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The ability of an input port to forward the link test pulse to its output port. If disabled the output port will always generate link pulses, regardless of input port link status." ::= { redundantTwisterTableEntry 3 } rtwActivePort OBJECT-TYPE SYNTAX INTEGER { primary (1), secondary (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the port that is both receiving and transmitting packets. If the active port is the secondary then the secondary led indicator will be turned on." ::= { redundantTwisterTableEntry 4 } rtwRedundantTransmission OBJECT-TYPE SYNTAX INTEGER { not-applicable (0), enable (1), disable (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The ability of the primary and secondary output ports to transmit the received main input signal simultaneously. When rtwModeControl is selectAB then this object is not selectable and a read of this value will always return not-applicable." ::= { redundantTwisterTableEntry 5 } rtwSecondarySwitchOver OBJECT-TYPE SYNTAX INTEGER { yes (1), no (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects whether an automatic switch from the primary port to the secondary port has taken place." ::= { redundantTwisterTableEntry 6 } rtwLinkPulseControl OBJECT-TYPE SYNTAX INTEGER { not-applicable (0), both-ports (1), active-port (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object controls the forwarding of the link test pulse to both the primary and secondary ports or the slected port in rtwActivePort. When rtwModeControl is selectAB then this object is not selectable and a read of this value will always return not-applicable." ::= { redundantTwisterTableEntry 7 } rtwModeControl OBJECT-TYPE SYNTAX INTEGER { redundant (1), selectAB (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This objects selects the operational mode. Redundant mode provides automatic switchover for port failure redundancy while ABSelect provides a basic A/B port selector." ::= { redundantTwisterTableEntry 8 } rtwABSelect OBJECT-TYPE SYNTAX INTEGER { selectA (1), selectB (2), not-selectable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object selects the output port that will send and receive packets. If the design of this module does not include the abiltiy to select the mode, then this object will default to not-selectable and no sets to this object will be allowed." ::= { redundantTwisterTableEntry 9 } -- ======================================================================= -- EPort Group -- EPortTable OID: 1.3.6.1.4.1.2745.2.6 -- ======================================================================= ePortTable OBJECT-TYPE SYNTAX SEQUENCE OF EPortTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of relevant information about the ports(s) contained within a module." ::= {ePortGroup 1 } ePortTableEntry OBJECT-TYPE SYNTAX EPortTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table containing port related information within a module." INDEX { ePortEntityIndex } ::= { ePortTable 1 } EPortTableEntry ::= SEQUENCE { ePortEntityIndex Integer32, ePortIfIndex Integer32, ePortType INTEGER, ePortDescription DisplayString, ePortName DisplayString, ePortLinkStatus INTEGER, ePortAdminState INTEGER, ePortOperStatus INTEGER, ePortDuplexAdmin INTEGER, ePortDuplexOper INTEGER, ePortSpeedAdmin INTEGER, ePortSpeedOper INTEGER, ePortAutoNegotiationAdmin INTEGER, ePortAutoNegotiationOper INTEGER, ePortReset INTEGER, ePortActivity INTEGER, ePortConnector INTEGER, ePortParentRelPos Integer32 } ePortEntityIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value, the entPhysicalIndex from the entity MIB, that identifies a port for which this entry contains information." ::= { ePortTableEntry 1 } ePortIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier indicating the MIB-II interface number of this port. NOTE: ports on media translators DO NOT conform to MIB-II definition of an interface." ::= { ePortTableEntry 2 } ePortType OBJECT-TYPE SYNTAX INTEGER{ other (1), e10BaseT (2), e10BaseFL-MM (3), e10BaseFL-SM (4), e100BaseTX (5), e100BaseFX-MM (6), e100BaseFX-SM (7), e10-100Base-TX (8), e1000Base-LX (9), e1000Base-SX (10), e1000Base-FX (11), e10Base-SX (12), e100Base-SX (13) } MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value that identifies the type of port. Included in the port type is the maximum speed at which this port may operate at and the cable type." ::= { ePortTableEntry 3 } ePortDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (1..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "A textual description of this type of port." ::= { ePortTableEntry 4 } ePortName OBJECT-TYPE SYNTAX DisplayString (SIZE (1..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "The user defined name of this port." ::= { ePortTableEntry 5 } ePortLinkStatus OBJECT-TYPE SYNTAX INTEGER { link-detected (1), no-link (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The link status of this port. This status indicates the reception of link test pulse signals generated from an attached device. This object is used in the ePortLinkStatusChangeTrap." ::= { ePortTableEntry 6 } ePortAdminState OBJECT-TYPE SYNTAX INTEGER { not-applicable (0), enable (1), disable (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The desired state of this port. If the design of this module does not include the abiltiy to control this port then this object will default to not-applicable and no sets to this object will be allowed. If the design does permit control then enable and disable are the only valid states that a user can set this object to. This object is used in the PortControlTrap." ::= { ePortTableEntry 7 } ePortOperStatus OBJECT-TYPE SYNTAX INTEGER { enable (1), disable (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the current operational state of this port." ::= { ePortTableEntry 8 } ePortDuplexAdmin OBJECT-TYPE SYNTAX INTEGER { not-applicable (0), half (1), full (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the desired state of half or full duplex mode for this port. If the design of this module does not include the ability to select duplex, then this object will default to not-applicable and no sets to this object will be allowed. If the design does permit duplex selection then half and full are the valid states that a user can set this object to." ::= { ePortTableEntry 9 } ePortDuplexOper OBJECT-TYPE SYNTAX INTEGER { half(1), full(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the current duplex mode of this port." ::= { ePortTableEntry 10 } ePortSpeedAdmin OBJECT-TYPE SYNTAX INTEGER { not-applicable (0), tenMbit (1), onehundredMbit (2), gigabit (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the current speed that this port is operating at. If the design of this module does not include the abiltiy to control the speed of this then this object will default to not-applicable and no sets to this object will be allowed. If the design does permit control then all but not-applicable are valid states that a user can set this object to." ::= { ePortTableEntry 11 } ePortSpeedOper OBJECT-TYPE SYNTAX INTEGER { tenMbit (1), onehundredMbit (2), gigabit (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the desired speed that this port is operating at." ::= { ePortTableEntry 12 } ePortAutoNegotiationAdmin OBJECT-TYPE SYNTAX INTEGER { not-applicable (0), enable (1), disable (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the current state of auto negotiation for this port. If the design of this module does not include the ability to select auto negotiation, then this object will default to not-applicable and no sets to this object will be allowed. If the design does permit auto negotiation selection then all but not-applicable are valid states that a user can set this object to." ::= { ePortTableEntry 13 } ePortAutoNegotiationOper OBJECT-TYPE SYNTAX INTEGER { enable (1), disable (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifices the desired state of auto negotiation selection. If enabled, this port is capable of auto negotiating full/half duplex and port speed selection." ::= { ePortTableEntry 14 } ePortReset OBJECT-TYPE SYNTAX INTEGER { reset (1), resetable (2), not-resetable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The trigger to reset this port. If the design of this module does not include this feature then this object will default to not-resetable and no sets to this object will be allowed. If the design does permit a reset then the only valid state that a user can set this object to is is reset. A read of this object will return either resetable or not-resetable." ::= { ePortTableEntry 15 } ePortActivity OBJECT-TYPE SYNTAX INTEGER { inactive (1), active (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates data reception and transmision activity on the active port(s)." ::= { ePortTableEntry 16 } ePortConnector OBJECT-TYPE SYNTAX INTEGER { other (1), rj11 (2), rj21 (3), rj45 (4), bnc (5), sc (6), st (7), sma (8), mt-rj (9), vf-45 (10) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the connector type that this port supports." ::= { ePortTableEntry 17 } ePortParentRelPos OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates this ports relative position in the module to which it is member of." ::= { ePortTableEntry 18 } -- ======================================================================= -- The serialPort Group -- serialPortTable OID: 1.3.6.1.4.1.2745.2.7 -- ======================================================================= serialPortTable OBJECT-TYPE SYNTAX SEQUENCE OF SerialPortTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of relevent information pertaining to each serial port contained within this system." ::= {serialPortGroup 1 } serialPortTableEntry OBJECT-TYPE SYNTAX SerialPortTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table, containing relevant information about a specific serial port contained within this system." INDEX { serialPortEntityIndex } ::= {serialPortTable 1} SerialPortTableEntry ::= SEQUENCE { serialPortEntityIndex Integer32, serialPortDescription DisplayString, serialPortName DisplayString, serialPortSpeed INTEGER, serialPortDataBits INTEGER, serialPortParity INTEGER, serialPortStopBits INTEGER, serialPortFlowControl INTEGER, serialPortConnector INTEGER } serialPortEntityIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value, the entPhysicalIndex from the entity MIB, which identifies this serial port." ::= { serialPortTableEntry 1 } serialPortDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (1..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "A textual description of this type of port." ::= { serialPortTableEntry 2 } serialPortName OBJECT-TYPE SYNTAX DisplayString (SIZE (1..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "The user defined name of this port." ::= { serialPortTableEntry 3 } serialPortSpeed OBJECT-TYPE SYNTAX INTEGER { baud-9600 (9600), baud-19200 (19200), baud-38400 (38400) } MAX-ACCESS read-only STATUS current DESCRIPTION "The speed that this port transmits and receives at." ::= { serialPortTableEntry 4 } serialPortDataBits OBJECT-TYPE SYNTAX INTEGER { five (5), six (6), seven (7), eight (8) } MAX-ACCESS read-only STATUS current DESCRIPTION "The number of bits in a character." ::= { serialPortTableEntry 5 } serialPortParity OBJECT-TYPE SYNTAX INTEGER { none (1), even (2), odd (3), mark (4), space (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The port's sense of a character parity bit." ::= { serialPortTableEntry 6 } serialPortStopBits OBJECT-TYPE SYNTAX INTEGER { one (1), one-five (2), two (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The number of stop bits for this port." ::= { serialPortTableEntry 7 } serialPortFlowControl OBJECT-TYPE SYNTAX INTEGER { none (1), xon-xoff (2), hardware (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of flow control for this port." ::= { serialPortTableEntry 8 } serialPortConnector OBJECT-TYPE SYNTAX INTEGER { db9 (1), db25 (2), rj45 (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the connector type that this port supports." ::= { serialPortTableEntry 9 } -- ====================================================================== -- Lancast Proprietary Traps -- NOTE: These trap numbers must be maintained. The use of trap numbers -- is our internal mechanism of mapping between v1 and v2 traps. -- -- NOTE: Other lancast proprietary mib files have traps specified. -- -- lcentity MIB uses trap number 10 entConfigChange -- -- Please verify any changes to prevent conflicts. -- ======================================================================= tempStatusChange NOTIFICATION-TYPE OBJECTS { chassisEntityIndex, chassisCurrentTemp, chassisMaxTemp } STATUS current DESCRIPTION "This trap will be sent when the temperature falls outside of the exceptable range. The values of chassisEntityIndex, chassisCurrentTemp and chassisMaxTemp will be included in this traps varBind list." ::= { lancastTraps 11 } backPlaneFailure NOTIFICATION-TYPE OBJECTS { modFirstSlot } STATUS current DESCRIPTION "This trap will be sent when there is a backplane failure. The value of modFirstSlot will be included in this traps varBind list." ::= { lancastTraps 12 } powerSupply5vChange NOTIFICATION-TYPE OBJECTS { powerSupplyEntityIndex, powerSupply5vCurrent, powerSupply5vMin, powerSupply5vMax, powerSupplyUnitIdentifier } STATUS current DESCRIPTION "This trap will be sent when the voltage from the 5 volt power supply falls outside of the exceptable range. The values of powerSupplyEntityIndex, powerSupply5vCurrent, powerSupplyMin, powerSupply5vMax and powerSupplyUnitIdentifier will be included in this traps varBind list." ::= { lancastTraps 13 } powerSupplyStatusChange NOTIFICATION-TYPE OBJECTS { powerSupplyEntityIndex, powerSupplyStatus, powerSupplyUnitIdentifier } STATUS current DESCRIPTION "This trap will be sent when a power supply is either turned on or off. The values of powerSupplyEntityIndex, powerSupplyStatus and powerSupplyUnitIdentifier will be included in this traps varBind list." ::= { lancastTraps 14 } powerSupplyInsertion NOTIFICATION-TYPE OBJECTS { powerSupplyEntityIndex, powerSupplyType, powerSupplyUnitIdentifier } STATUS current DESCRIPTION "This trap will be sent when a power supply is inserted. The values of powerSupplyEntityIndex, powerSupplyType and powerSupplyUnitIdentifier will be included in this traps varBind list." ::= { lancastTraps 15 } powerSupplyRemoval NOTIFICATION-TYPE OBJECTS { powerSupplyEntityIndex, powerSupplyType, powerSupplyUnitIdentifier } STATUS current DESCRIPTION "This trap will be sent when a power supply is removed. The values of powerSupplyEntityIndex, powerSupplyType and powerSupplyUnitIdentifier will be included in this traps varBind list." ::= { lancastTraps 16 } chassisEntityReset NOTIFICATION-TYPE OBJECTS { lastEntityResetIndex, lastEntityResetReason, lastEntityResetTime } STATUS current DESCRIPTION "This trap is sent when a chassis is reset. The values of lastEntityResetIndex, lastEntityResetReason, and lastEntityResetTime will be included in this traps varBind list." ::= { lancastTraps 17 } moduleEntityReset NOTIFICATION-TYPE OBJECTS { lastEntityResetIndex, lastEntityResetReason, lastEntityResetTime, modType, modFirstSlot, modNumSlotsOccupied } STATUS current DESCRIPTION "This trap is sent when a module is reset. The values of lastEntityResetIndex, lastEntityResetReason, and lastEntityResetTime, modType, modFirstSlot and modNumSlotsOccupied will be included in this traps varBind list." ::= { lancastTraps 18 } eportEntityReset NOTIFICATION-TYPE OBJECTS { lastEntityResetIndex, lastEntityResetReason, lastEntityResetTime, modType, modFirstSlot, modNumSlotsOccupied, ePortParentRelPos } STATUS current DESCRIPTION "This trap is sent when a port is reset. The values of lastEntityResetIndex, lastEntityResetReason, and lastEntityResetTime, modType, modFirstSlot, modNumSlotsOccupied, and ePortParentRelPos will be included in this traps varBind list." ::= { lancastTraps 19 } moduleInsertion NOTIFICATION-TYPE OBJECTS { modEntityIndex, modType, modFirstSlot, modNumSlotsOccupied } STATUS current DESCRIPTION "This trap is sent when a module is inserted to a slot. The values of modEntityIndex, modFirstSlot, modType, modNumSlotsOccupied will be included in this traps varBind list." ::= { lancastTraps 20 } moduleRemoval NOTIFICATION-TYPE OBJECTS { modEntityIndex, modType, modFirstSlot, modNumSlotsOccupied } STATUS current DESCRIPTION "This trap is sent when a module is removed from a slot. The values of modEntityIndex, modFirstSlot, modType, modNumSlotsOccupied will be included in this traps varBind list." ::= { lancastTraps 21 } unknownModule NOTIFICATION-TYPE OBJECTS { modEntityIndex, modType, modFirstSlot } STATUS current DESCRIPTION "This trap is sent when a module is inserted and it's type cannot be determined. The values of modEntityIndex, modType, modFirstSlot, modNumSlotsOccupied will be included in this traps varBind list." ::= { lancastTraps 22 } moduleFailure NOTIFICATION-TYPE OBJECTS { modFirstSlot } STATUS current DESCRIPTION "This trap is sent when a module fails and thus is inaccessible. The value of modFirtSlot will be included in this traps varBind list." ::= { lancastTraps 23 } ePortLinkStatusChange NOTIFICATION-TYPE OBJECTS { ePortEntityIndex, ePortLinkStatus, modType, modFirstSlot, modNumSlotsOccupied } STATUS current DESCRIPTION "This trap is sent when there is a change in the link state of a port. The values of ePortLinkStatus, ePortIndex, modType, modFirstSlot, and modNumSlotsOccupied will be included in this traps varBind list." ::= { lancastTraps 24 } ePortAdminChange NOTIFICATION-TYPE OBJECTS { ePortEntityIndex, ePortAdminState, modType, modFirstSlot, modNumSlotsOccupied } STATUS current DESCRIPTION "This trap is sent when a user changes the admin state of a port from enable to disable or vice versa. The values of ePortAdminState ePortEntityIndex, modType, modFirstSlot, modNumSlotsOccupied, will be included in this traps varBind list." ::= { lancastTraps 25 } rtwSwitchOverChange NOTIFICATION-TYPE OBJECTS { rtwEntityIndex, rtwActivePort, modFirstSlot, modNumSlotsOccupied } STATUS current DESCRIPTION "This trap is sent when a switchover from the primary to the secondary port and vice versa has occured. The values of rtwEntityIndex, rtwActivePort, modFirstSlot, modNumSlotsOccupied will be included in this traps varBind list." ::= { lancastTraps 26 } END