-- This file contains a version of the old 3Com PDD alarm MIB. These were -- known as gauges and have now been superceeded by the RMON alarm MIB. -- This whole MIB is therefore deprecated. Accessing any item in this MIB will -- actually access the appropriate RMON alarm item. -- -------------------------------------------------------------------- -- ************************ GAUGES GROUP **************************** -- -------------------------------------------------------------------- A3COMMG009-GAUGES DEFINITIONS ::= BEGIN IMPORTS gauges FROM A3COM0004-GENERIC OBJECT-TYPE FROM RFC-1212 DisplayString FROM RFC1213-MIB TRAP-TYPE FROM RFC-1215 ; -- Implementation of the Gauges group is optional for all -- Isolan systems. -- ---------------------------------------- -- GAUGE TABLE -- ---------------------------------------- gaugeTable OBJECT-TYPE SYNTAX SEQUENCE OF GaugeTableEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "A table used to define Alarms." ::= { gauges 1 } gaugeTableEntry OBJECT-TYPE SYNTAX GaugeTableEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "This table allows Alarms to be set-up on items in the MIB." INDEX { gaugeIndex } ::= { gaugeTable 1 } GaugeTableEntry ::= SEQUENCE { gaugeIndex INTEGER, gaugeItemId OBJECT IDENTIFIER, gaugeItemType INTEGER, gaugeSamplesPerAverage INTEGER, gaugeSamplePeriod INTEGER, gaugeValue INTEGER, gaugePeakValue INTEGER, gaugeThresholdLevel INTEGER, gaugeRecoveryLevel INTEGER, gaugeThresholdAction INTEGER, gaugeRecoveryAction INTEGER, gaugeState INTEGER, gaugeOwner DisplayString } gaugeIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS deprecated DESCRIPTION "Unique identifier for a row in the Alarm Table. Allocated by the Alarms Subsystem. An integer in the range 1..gaugeTableSize." ::= { gaugeTableEntry 1 } gaugeItemId OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-write STATUS deprecated DESCRIPTION "The object Id and qualifier of the item to be monitored by this alarm. " ::= { gaugeTableEntry 2 } gaugeItemType OBJECT-TYPE SYNTAX INTEGER { counter (1), signedMeter (2), unsignedMeter (3) } ACCESS read-write STATUS deprecated DESCRIPTION "A 'counter', by definition will always be a positive number. 'Meters' can be signed or unsigned." ::= { gaugeTableEntry 3 } gaugeSamplesPerAverage OBJECT-TYPE SYNTAX INTEGER { nonAveraging (1), twoSamples (2), threeSamples (3), maxSamples (4) } ACCESS read-write STATUS deprecated DESCRIPTION "The number of samples used to calculate the Alarm Value. The default number of samples is four. If a SamplesPerAverage value of one is used, no average is calculated and the GaugeValue will be the most recent sample." ::= { gaugeTableEntry 4 } gaugeSamplePeriod OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-write STATUS deprecated DESCRIPTION "Number of seconds between samples. The total averaging period is given by (gaugeSamplesPerAverage * gaugeSamplePeiod) secs." ::= { gaugeTableEntry 5 } gaugeValue OBJECT-TYPE SYNTAX INTEGER (0..4294967295) ACCESS read-write STATUS deprecated DESCRIPTION "The most recently computed average of the item being monitored. For a `meter' alarm, this is the simple average of the samples. For a 'counter' alarm, this is the average of the differences between successive samples. Counters and unsignedMeters are unsigned 32-bit values and have a maximum value of 4294967295. signedMeters are signed 32-bit values and have a maximum value of +-2147483647 divided by the value of gaugeSamplesPerAverage ." ::= { gaugeTableEntry 6 } gaugePeakValue OBJECT-TYPE SYNTAX INTEGER (0..4294967295) ACCESS read-write STATUS deprecated DESCRIPTION "The highest recorded Alarm Value. This will be either a signed or unsigned 32 bit value depending on the gaugeItemType" ::= { gaugeTableEntry 7 } gaugeThresholdLevel OBJECT-TYPE SYNTAX INTEGER (0..4294967295) ACCESS read-write STATUS deprecated DESCRIPTION "The threshold value of the the Alarm which causes the ThresholdState to move from the 'ready' state to the 'fired' state and also causes the the ThresholdAction to be taken. It will be either a signed or unsigned 32-bit integer depending on the gaugeItemType." ::= { gaugeTableEntry 8 } gaugeRecoveryLevel OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS deprecated DESCRIPTION "The threshold value of the the Alarm which causes the ThresholdState to move from the `fired' state to the `ready' state and also causes the the RecoveryAction to be taken. This value will be either a signed or unsigned 32-bit integer depending on the gaugeItemType." ::= { gaugeTableEntry 9 } gaugeThresholdAction OBJECT-TYPE SYNTAX INTEGER { noAction (1), sendTrap (2), -- Send a Trigger event to manager disable (3), -- e.g. turn off port enable (4), -- e.g. turn on port notifyAndBlipPortOff (5), notifyAndBlipCardOff (6), notifyAndDisablePort (8), notifyAndDisableCard (9), blipPortOff (12), blipCardOff (13), disablePort (14), disableCard (15), notifyAndResilientSwitch (18), notifyBandwidthExceeded (19), notifyErrorsExceeded (20), notifyPollFailed (22), notifyFilterBridgePort (23) } ACCESS read-write STATUS deprecated DESCRIPTION "This object identifies the action to be taken when an Alarm crosses the Threshold Level. The default action will be to send a trigger event (sendTrap). The other actions are device specific and may not be available on all devices. See the RMON Event Table for the actions supported by this device." ::= { gaugeTableEntry 10 } gaugeRecoveryAction OBJECT-TYPE SYNTAX INTEGER { noAction (1), sendTrap (2), -- Send a Trigger event to manager disable (3), -- e.g. turn off port enable (4), -- e.g. turn on port notifyAndEnablePort (10), notifyAndEnableCard (11), enablePort (16), enableCard (17), notifyPollSuccess (21), notifyUnfilterBridgePort (24) } ACCESS read-write STATUS deprecated DESCRIPTION "This object identifies the action to be taken when a 'fired' Alarm crosses the Recovery Level. The default action will be to send a recovery event (sendTrap). The actions for 'disable' and 'enable' are device specific." ::= { gaugeTableEntry 11 } gaugeState OBJECT-TYPE SYNTAX INTEGER { onTriggersEnabled (1), onTriggersDisabled (2), off (3), -- Maps to underCreation deleted (4), -- Maps to invalid autoCalibrate(5) } ACCESS read-write STATUS deprecated DESCRIPTION " onTriggersEnabled - This is the normal active state of a alarm. The gaugeValue is updated on every sample and if it crosses the Threshold or Recovery Levels, the corresponding Action will be taken. onTriggersDisabled - This is used when a new device, or alarm is set up and the Threshold and Recovery Levels have not been calibrated. The Alarm runs as normal and the gaugeValue and peakValue are updated. However, if the gaugeValue crosses the Threshold or Recovery Levels, no action is taken. off - This de-activates the alarm, allowing it to be configured safely . Before updating any of the Alarm fields the alarm SHOULD be turned off. Turning the alarm 'off' and then 'on' will not lose any of the sampling data, gaugeValue, peakValue, or thresholdStatus. Updates to the index fields will fail since they are read-only. deleted - An alarm is invalidated by setting it to 'deleted'. A 'deleted' alarm will not be returned by a 'GetNext' request. autoCalibrate - Updates the Threshold and Recovery values according to the current peak value. The gaugeState will then be set to 'onTriggersEnabled'. This can be done when the gaugeState is in states (1), (2), or (3). After this operation: thresholdLevel = peakValue * %gaugeThresholdLevelScaler recoveryLevel = peakValue * %gaugeRecoveryLevelScaler gaugeState = onTriggersEnabled When the gaugeState is set to either of the 'on' states, all the fields for the Alarm are validated. If any of the fields are invalid, the operation will fail. The sampling data, gaugeValue, peakValue and thresholdState can be reset by writing 'onTriggersEnabled', 'onTriggers- Disabled' , or 'autoCalibrate' to the gaugeState when it is already in either of the 'on' states." ::= { gaugeTableEntry 12 } gaugeOwner OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS deprecated DESCRIPTION "The entity that configured this entry and is therefore using the resources assigned to it." ::= { gaugeTableEntry 13 } gaugeTableSize OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS deprecated DESCRIPTION "Number of entries in Alarm Table. The size of the Alarm Table depends on the requirements and available resources of the device. The actual maximum will probably be around 1000." ::= { gauges 2 } gaugeThresholdLevelScaler OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS deprecated DESCRIPTION "The ThresholdLevel is set to this percentage of the peakValue when the Alarm is auto-calibrated. e.g gaugeThresholdLevelScaler = 120 gaugePeakValue = 360 After writing 'calibrateTriggers' to the gaugeState: ThresholdLevel = 120/100 * 360 = 432" ::= { gauges 3 } gaugeRecoveryLevelScaler OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS deprecated DESCRIPTION "The RecoveryLevel is set to this percentage of the peakValue when the Alarm is auto-calibrated. e.g gaugeRecoveryLevelScaler = 90 gaugePeakValue = 360 After writing 'calibrateTriggers' to the gaugeState: RecoveryLevel = 90/100 * 360 = 324" ::= { gauges 4 } gaugeTableUpdate OBJECT-TYPE SYNTAX INTEGER { deleteAll (1) -- Set all Alarms to 'deleted' } ACCESS write-only STATUS deprecated DESCRIPTION "Performs the specified operation on every Alarm in the table." ::= { gauges 5 } gaugeConfigureObjId OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS write-only STATUS deprecated DESCRIPTION "Object Id and qualifier of alarm(s) to be updated." ::= { gauges 6 } gaugeConfigureColumn OBJECT-TYPE SYNTAX INTEGER { itemType(1), samplesPerAverage(2), samplePeriod(3), thresholdLevel(4), recoveryLevel(5), thresholdAction(6), recoveryAction(7), gaugeState(8) } ACCESS write-only STATUS deprecated DESCRIPTION "Alarm Table Column to be updated." ::= { gauges 7 } gaugeConfigureValue OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS write-only STATUS deprecated DESCRIPTION "Value to be written to the 'gaugeConfigureColumn' of the Alarms which match the 'gaugeConfigureObjId'. Writing to this value initiates the operation." ::= { gauges 8 } gaugeNextFreeIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS deprecated DESCRIPTION "Indicates the gaugeIndex which must be used to create the next alarm. Index is set to GAUGE_TABLE_FULL (zero) if there are no free rows in the table." ::= { gauges 9 } -- 3Com Alarm Traps -- These are no longer used. The RMON traps are used in preference. -- These definitions are provided only for backward compatibility gaugesThresholdTrap TRAP-TYPE ENTERPRISE a3Com VARIABLES { gaugeItemId, gaugeThresholdLevel, gaugeSamplePeriod, gaugeSamplesPerAverage } DESCRIPTION " Generated when the Alarm value for this Alarm crosses the Threshold Level." ::= 16 gaugesRecoveryTrap TRAP-TYPE ENTERPRISE a3Com VARIABLES { gaugeItemId, gaugeRecoveryLevel, gaugeSamplePeriod, gaugeSamplesPerAverage } DESCRIPTION " Generated when the Alarm value for this Alarm crosses the Recovery Level." ::= 17 END A3COMMG005-MRM-MIB DEFINITIONS ::= BEGIN IMPORTS multiRepeater FROM A3COM0004-GENERIC gaugeThresholdLevel, gaugeSamplePeriod, gaugeSamplesPerAverage FROM A3COMMG009-GAUGES DisplayString, ifIndex FROM RFC1213-MIB OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 ; mrmBasicPackage OBJECT IDENTIFIER ::= {multiRepeater 1} mrmBasCardPackage OBJECT IDENTIFIER ::= {mrmBasicPackage 1} -- -- Start of MRM Basic Group -- -- -- MRM Basic Group Table -- mrmCardTable OBJECT-TYPE SYNTAX SEQUENCE OF MrmCardEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of descriptive and status information about the groups of ports." ::= {mrmBasCardPackage 1} mrmCardEntry OBJECT-TYPE SYNTAX MrmCardEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the table, containing information about a single group of ports." INDEX {mrmCardServiceId, mrmCardIndex} ::= {mrmCardTable 1} MrmCardEntry ::= SEQUENCE { mrmCardServiceId INTEGER, mrmCardIndex INTEGER, mrmCardPortCapacity INTEGER, mrmCardTest INTEGER, mrmCardDOBPorts INTEGER, mrmCardMDIenable INTEGER } mrmCardServiceId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This identifies one of the repeaters within the chassis as the target of a request." ::= {mrmCardEntry 1} mrmCardIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the card within the repeater for which this entry contains information." ::= {mrmCardEntry 2} mrmCardPortCapacity OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The mrmCardPortCapacity is the number of ports that can be contained within the group. Valid range is 1-1024. Within each group, the ports are uniquely numbered in the range from 1 to mrmCardPortCapacity. Note: In practice, this will generally be the number of ports on a module, card, or board, and the port numbers will correspond to numbers marked on the physical embodiment." ::= {mrmCardEntry 3} mrmCardTest OBJECT-TYPE SYNTAX INTEGER { noTest (1), test (2), testing (3), passed (4), failed (5) } ACCESS read-write STATUS mandatory DESCRIPTION "An object that allows the user to test the operation of a card. Writing test(2) to this object forces the card to perform a disruptive test to determine if the card is functioning properly. Reading this object while the card is under test return the value testing(3). When the test is completed, reading this value will return either passed(4) or failed(5)." ::= {mrmCardEntry 4} mrmCardDOBPorts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "MSH Repeater Cards have the ability to disable ports at power up or reset. Ports configured in this way are useful for configuring resilient links because they prevent loops in the network from occurring at startup. The disable on boot feature is determined according to a hardware strap which cannot be changed via software. This parameter is a mask containing a single bit for each port on the card. Port 1 is represented by bit 0 and so-on. If a bit representing a particular port is 0 this port boots up disabled. If the bit is a 1 the port boots up enabled. This parameter allows the state of these parameters to be rapidly determined by a network management application." ::= {mrmCardEntry 5} mrmCardMDIenable OBJECT-TYPE SYNTAX INTEGER { unknown (1), mdiDisabled (2), mdiEnabled (3), notApplicable (4) } ACCESS read-only STATUS mandatory DESCRIPTION "10Base-T line cards are normally configured (mdi_disabled(2)) to link to an external network device ( internal crossover ). Port 1 may be configured ( mdi_enabled(3) ) to link to another 10Base-T line card ( with no internal crossover ). This parameter allows the configuration to be determined. Note ECS line cards show unknown(1) since the configuration cannot be accessed via the management interface." ::= {mrmCardEntry 6} mrmBasPortPackage OBJECT IDENTIFIER ::= {mrmBasicPackage 2} -- -- MRM Basic Port Table -- mrmPortTable OBJECT-TYPE SYNTAX SEQUENCE OF MrmPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of descriptive and status information about the ports." ::= {mrmBasPortPackage 1} mrmPortEntry OBJECT-TYPE SYNTAX MrmPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the table, containing information about a single port." INDEX {mrmPortServiceId, mrmPortCardIndex, mrmPortIndex} ::= {mrmPortTable 1} MrmPortEntry ::= SEQUENCE { mrmPortServiceId INTEGER, mrmPortCardIndex INTEGER, mrmPortIndex INTEGER, mrmPortInterfaceType INTEGER, mrmPortConnectorType INTEGER, mrmPortAdminStatus INTEGER, mrmPortAutoPartitionState INTEGER, mrmPortLinkState INTEGER, mrmPortBootState INTEGER, mrmPortESTFilter INTEGER, mrmPortPartitionEvent INTEGER, mrmPortLinkStateEvent INTEGER, mrmPortSecurityAvailable INTEGER, mrmPortLinkPulse INTEGER, mrmPortModule INTEGER, mrmPortDUDAction INTEGER, mrmPortFunction INTEGER, mrmPortTest INTEGER } mrmPortServiceId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the repeater which this entry contains information." ::= {mrmPortEntry 1} mrmPortCardIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the group containing the port for which this entry contains information." ::= {mrmPortEntry 2} mrmPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the port within the group for which this entry contains information. This value can never be greater than mrmCardPortCapacity for the associated group." REFERENCE "Reference IEEE 802.3 Rptr Mgt, 19.2.6.2,aPortID." ::= {mrmPortEntry 3} mrmPortInterfaceType OBJECT-TYPE SYNTAX INTEGER { unknown (1), maleAUI (2), femaleAUI (3), thinCoax (4), twistedPair (5), unshieldedTP (6), fiber (7), t4 (8) } ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the type of electrical interface made available at the interface to the card for this port. The interface does not necessarily specify what the actual media to end station is." ::= {mrmPortEntry 4} mrmPortConnectorType OBJECT-TYPE SYNTAX INTEGER { unknown (1), rj45 (2), telco (3), st (4), sma (5), dtype-15 (6), bnc (7), sc (8) } ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the type of the physical connector through which one would attach to this card. This is distinct from the media type. For example UTP may be connected to the port via either an RJ45 or a Telco connector." ::= {mrmPortEntry 5} mrmPortAdminStatus OBJECT-TYPE SYNTAX INTEGER { enabled (1), disabled (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this object to disabled(2) disables the port. A disabled port neither transmits nor receives. Once disabled, a port must be explicitly enabled to restore operation. A port which is disabled when power is lost or when a reset is exerted shall remain disabled when normal operation resumes. The admin status takes precedence over auto- partition and functionally operates between the auto-partition mechanism and the AUI/PMA. Setting this object to enabled(1) enables the port and exerts a BEGIN on the port's auto-par tition state machine. In effect, when a port is disabled, the value of mrmPortAutoPartitionState for that port is frozen until the port is next enabled. When the port becomes enabled, the mrmPortAutoPartitionState becomes notAutoPartitioned(2), regardless of its pre-disabling state.)" ::= {mrmPortEntry 6} mrmPortAutoPartitionState OBJECT-TYPE SYNTAX INTEGER { partitioned (1), unpartitioned (2) } ACCESS read-only STATUS mandatory DESCRIPTION "The autoPartitionState flag indicates whether the port is currently partitioned by the repeater's auto-partition protection. The conditions that cause port partitioning are specified in partition state machine in Section 9 IEEE 802.3 Std]. They are not differentiated here." REFERENCE "Reference IEEE 802.3 Rptr Mgt, 19.2.6.2, aAutoPartitionState." ::= {mrmPortEntry 7} mrmPortLinkState OBJECT-TYPE SYNTAX INTEGER { present (1), absent (2) } ACCESS read-only STATUS mandatory DESCRIPTION "This object reflects the presence or absence of signal on this port. The signal may be either light in the case of fiber, or general link present in the case of copper. The value of this parameter is correct regardless of the state the admin state or the partition state." ::= {mrmPortEntry 8} mrmPortBootState OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } ACCESS read-only STATUS mandatory DESCRIPTION "A repeater port may be enabled or disabled after a reset. This parameter indicates the default for this port." ::= {mrmPortEntry 9} mrmPortESTFilter OBJECT-TYPE SYNTAX INTEGER { forwardMAC (1), forwardIP (2), forwardAll (127), forwardNone (128) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute determines whether and which address information is extracted from packets received on a port and forwarded to the end station database. It is recommended that this attribute be disabled for inter-repeater links to prevent the database being filled with remote information. To disable this feature for all address types write the value forwardNone (128) to this variable." ::= {mrmPortEntry 10} mrmPortPartitionEvent OBJECT-TYPE SYNTAX INTEGER { enabled (1), disabled (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies whether a trap should be sent if the port partition state changes." ::= {mrmPortEntry 11} mrmPortLinkStateEvent OBJECT-TYPE SYNTAX INTEGER { enabled (1), disabled (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies whether a trap should be sent if the link state changes." ::= {mrmPortEntry 12} mrmPortSecurityAvailable OBJECT-TYPE SYNTAX INTEGER { securityI (1), notAvailable (2), securityII (3) } ACCESS read-only STATUS mandatory DESCRIPTION "Specifies whether security is an available feature on this port. Only ports that have this feature available can have an entry in the repeater security table. A value of securityI(1) indicates that the port can support a single authorised address, while securityII(3) indicates that it can support multiple authorised addresses." ::= {mrmPortEntry 13} mrmPortLinkPulse OBJECT-TYPE SYNTAX INTEGER { enabled (1), disabled (2), notApplicable (3) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute determines if link pulse generating and monitoring is enabled or disabled for a 10BaseT port. The attribute may take the values of enabled (standard) or disabled (non standard)." ::= {mrmPortEntry 14} mrmPortModule OBJECT-TYPE SYNTAX INTEGER { unknown (1), modularPort (2), notModularPort (3) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates whether the port is a modular port or not." ::= {mrmPortEntry 15} mrmPortDUDAction OBJECT-TYPE SYNTAX INTEGER { noAction (1), notify (2), disconnect (3), notAvailable (4) } ACCESS read-write STATUS mandatory DESCRIPTION "DUD Action for this port. This specifies the action to be taken if an unauthorised station is seen on this port. The possible actions are:- noAction(1) ignore, do nothing notify(2) send a trap to the management station disconnect(3) disable the port notAvailable(4) the feature is not available for this port. In this case an attempt to set this object to some other value will be rejected." ::= {mrmPortEntry 16} mrmPortFunction OBJECT-TYPE SYNTAX INTEGER { unknown (1), repeater (2), bridge (3), switch (4) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the function of the port." ::= {mrmPortEntry 17} mrmPortTest OBJECT-TYPE SYNTAX INTEGER { unknown (1), test (2), passed (3), failed (4) } ACCESS read-write STATUS mandatory DESCRIPTION "An object that allows the user to test the operation of a port. Writing test(2) to this object forces the port to perform a disruptive test to determine if the port is functioning properly. Reading this object returns the result of the test, either passed(3) or failed(4). If this object is read while a test is in progress, the response to the read request is not sent until the result of the test is known. If this object is read for a port which has never been tested, unknown(1) is returned." ::= {mrmPortEntry 18} mrmMonitorPackage OBJECT IDENTIFIER ::= {multiRepeater 2} mrmMonRepeaterPackage OBJECT IDENTIFIER ::= {mrmMonitorPackage 1} -- -- End of MRM Basic Group -- -- -- Start of MRM Monitor Group -- -- -- MRM Monitor Repeater Level Objects -- mrmMonitorRepTable OBJECT-TYPE SYNTAX SEQUENCE OF MrmMonitorRepEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of performance and error statistics for the ports." ::= {mrmMonRepeaterPackage 1} mrmMonitorRepEntry OBJECT-TYPE SYNTAX MrmMonitorRepEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table provides statistical and control information concerning the entire repeater." INDEX {mrmMonRepServiceId} ::= {mrmMonitorRepTable 1} MrmMonitorRepEntry ::= SEQUENCE { mrmMonRepServiceId INTEGER, mrmMonRepReadableFrames Counter, mrmMonRepUnicastFrames Counter, mrmMonRepMulticastFrames Counter, mrmMonRepBroadcastFrames Counter, mrmMonRepReadableOctets Counter, mrmMonRepUnicastOctets Counter, mrmMonRepMulticastOctets Counter, mrmMonRepBroadcastOctets Counter, mrmMonRepFCSErrors Counter, mrmMonRepAlignmentErrors Counter, mrmMonRepFrameTooLongs Counter, mrmMonRepShortEvents Counter, mrmMonRepRunts Counter, mrmMonRepTxCollisions Counter, mrmMonRepLateEvents Counter, mrmMonRepVeryLongEvents Counter, mrmMonRepDataRateMismatches Counter, mrmMonRepAutoPartitions Counter, mrmMonRepTotalErrors Counter, mrmMonRepBound0 Counter, mrmMonRepBound1 Counter, mrmMonRepBound2 Counter, mrmMonRepBound3 Counter, mrmMonRepBound4 Counter, mrmMonRepBound5 Counter, mrmMonRepAction INTEGER, mrmMonRepBandwidthUsed Counter, mrmMonRepErrorsPer10000Packets Counter } mrmMonRepServiceId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This parameter is used as the index in this table. A modular chassis contains potentially many repeater services. Each repeater service contains a number of cards (or groups). This parameter allows one of those repeaters to be selected." ::= {mrmMonitorRepEntry 1} mrmMonRepReadableFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one for each frame whose OctetCount is greater than or equal to minFrameSize and less than or equal to maxFrameSize and for which FCSError is not asserted that is received by the repeater. NOTE: This counter does not really exist. It is calculated by adding together all the port counters within this repeater." ::= {mrmMonitorRepEntry 2} mrmMonRepUnicastFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one for each readable frame seen by the Repeater that is addressed to a unicast (non Card) address." ::= {mrmMonitorRepEntry 3} mrmMonRepMulticastFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one for each readable frame seen by the Repeater that is addressed to a multicast (non broadcast) address." ::= {mrmMonitorRepEntry 4} mrmMonRepBroadcastFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one for each readable frame seen by the Repeater that is addressed to the broadcast address ffffffffffff." ::= {mrmMonitorRepEntry 5} mrmMonRepReadableOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by the octet count for each readable frame received by the repeater. NOTE: This counter does not really exist. It is calculated by adding together all the port counters within this repeater." ::= {mrmMonitorRepEntry 6} mrmMonRepUnicastOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object is the number of octets contained in valid frames that have been received on this port in which the destination field was a unicast address. The approximate minimum time for rollover of this counter is 58 minutes." ::= {mrmMonitorRepEntry 7} mrmMonRepMulticastOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object is the number of octets contained in valid frames that have been received on this port in which the destination was a multicast address. The approximate minimum time for rollover of this counter is 58 minutes." ::= {mrmMonitorRepEntry 8} mrmMonRepBroadcastOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object is the number of octets contained in valid frames that have been received on this port in which the destination was the broadcast address ffffffffffff. By attaching a gauge to this counter one can monitor the port for broadcast storms. Action can then be taken to automatically recover network normal operation. The approximate minimum time for rollover of this counter is 58 minutes." ::= {mrmMonitorRepEntry 9} mrmMonRepFCSErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one for each frame with an FCS error that does not have a framing error and which is of legal frame size received by the repeater. NOTE: This counter does not really exist. It is calculated by adding together all the port counters within this repeater." ::= {mrmMonitorRepEntry 10} mrmMonRepAlignmentErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one for each frame with an FCS error that does have a framing error and which is of legal frame size received by the repeater. NOTE: This counter does not really exist. It is calculated by adding together all the port counters within this repeater." ::= {mrmMonitorRepEntry 11} mrmMonRepFrameTooLongs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one for each frame whose octet count is greater than the max frame size that is received by the repeater. NOTE: This counter does not really exist. It is calculated by adding together all the port counters within this repeater." ::= {mrmMonitorRepEntry 12} mrmMonRepShortEvents OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one for each carrier event whose duration is less than short event max time that is detected by the repeater. NOTE: This counter does not really exist. It is calculated by adding together all the port counters within this repeater." ::= {mrmMonitorRepEntry 13} mrmMonRepRunts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one for each carrier event whose duration is greater than short event max time and less than valid packet min time and which does not suffer a collision detected by the repeater. NOTE: This counter does not really exist. It is calculated by adding together all the port counters within this repeater." ::= {mrmMonitorRepEntry 14} mrmMonRepTxCollisions OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one for any CarrierEvent signal on any port of this repeater for which the CollisionEvent signal on this port is asserted. The approximate minimum time for rollover of this counter is 16 hours." ::= {mrmMonitorRepEntry 15} mrmMonRepLateEvents OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one each time a collisions occurs after valid packet min time, a late event is counted as both a collision and as a late event. NOTE: This counter does not really exist. It is calculated by adding together all the port counters within this repeater." ::= {mrmMonitorRepEntry 16} mrmMonRepVeryLongEvents OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one each time a carrier event occurs whose duration is greater than the MAU Jabber Lockup Protection time. NOTE: This counter does not really exist. It is calculated by adding together all the port counters within this repeater." ::= {mrmMonitorRepEntry 17} mrmMonRepDataRateMismatches OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one each time a packet has been received by this repeater with the data rate detectably mismatched from the local frequency. NOTE: This counter does not really exist. It is calculated by adding together all the port counters within this repeater." ::= {mrmMonitorRepEntry 18} mrmMonRepAutoPartitions OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one each time the repeater has automatically partitioned any port. NOTE: This counter does not really exist. It is calculated by adding together all the port counters within this repeater." ::= {mrmMonitorRepEntry 19} mrmMonRepTotalErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of errors which have occurred on all ports on all groups of this repeater. This counter is the summation of the values of the mrmMonCardTotalErrors counters for all of the cards in the repeater. It is the sum of the following: FCS, Alignment, Frames Too Long, Short Events, Late Events, Very Long Events and Data Rate Mismatches. As a general indicator the individual error counters are too detailed. This parameter gives a very good monitor type parameter." ::= {mrmMonitorRepEntry 20} mrmMonRepBound0 OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object is a summation of the number of frames (including error frames) with a length of 64 octets which were received by each port on every card of this repeater." ::= {mrmMonitorRepEntry 21} mrmMonRepBound1 OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object is a summation of the number of frames (including error frames) with a length of between 65 and 127 octets inclusive which were received by each port on every card of this repeater." ::= {mrmMonitorRepEntry 22} mrmMonRepBound2 OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object is a summation of the number of frames (including error frames) with a length of between 128 and 255 octets inclusive which were received by each port on every card of this repeater." ::= {mrmMonitorRepEntry 23} mrmMonRepBound3 OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object is a summation of the number of frames (including error frames) with a length of between 256 and 511 octets inclusive which were received by each port on every card of this repeater." ::= {mrmMonitorRepEntry 24} mrmMonRepBound4 OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object is a summation of the number of frames (including error frames) with a length of between 512 and 1023 octets inclusive which were received by each port on every card of this repeater." ::= {mrmMonitorRepEntry 25} mrmMonRepBound5 OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object is a summation of the number of frames (including error frames) with a length of between 1024 and 1518 octets inclusive which were received by each port on every card of this repeater." ::= {mrmMonitorRepEntry 26} mrmMonRepAction OBJECT-TYPE SYNTAX INTEGER { clearCounters (1), noAction (128) } ACCESS read-write STATUS mandatory DESCRIPTION "This object allows repeater stats specific actions to be implemented. There is only one action currently defined, 'clearCounters'. Writing this value to a repeater entry will clear ALL counters in this repeater. That include port stats, card and repeater totals. If this object is read then noAction will be returned." ::= {mrmMonitorRepEntry 27} mrmMonRepBandwidthUsed OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This is a high level 'smart MIB' object. This object provides a running average of the bandwidth in use. This value is calculated locally on the agent and so does not require processor bandwidth from the management station or occupy valuable network bandwidth communicating with that station. By default an agent supporting this parameter will exhibit the following characteristics: 1) The parameter will be recalculated at approx 15 second intervals 2) Every calculation period the device will read the value of rptrMonitorPortReada bleOctets. 3) The calculation will be performed on the most recent 4 samples as follows: 4 Sum(sample(i)/(time(i) * K)) * 100/4 i=1 Sample(i) is rptrMonitorPortReadableOctets(i) - rptrMonitorPortReadableOctets(i-1) time(i) is the time between sample(i-1) and sample(i) K is the max bytes per unit time (i.e. the available bandwidth K depends on the ring speed. The value is expressed as a percentage. A default threshold exists on this average so that if a calculated average exceeds 15% a trap will be sent to the management station. Further traps will not be sent until the average drops to below 10%. A particular device may provide a means of changing the number of samples, the averaging period, threshold and threshold action if it so wishes." ::= {mrmMonitorRepEntry 28} mrmMonRepErrorsPer10000Packets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This is a high level 'smart MIB' object. This object provides a running average of the bandwidth in use. The value of this value is calculated locally on the agent and so does not require processor bandwidth from a management station or occupy valuable network bandwidth communicating with that station. By default an agent supporting this parameter will exhibit the following behaviour: 1) The parameter will be recalculated at approx 15 second intervals. 2) Every calculation period the device will read the value of rptrMonitorPortTotalErrors and rptrMonitorPortReadableFrames. 3) The calculation will be performed on the most recent 4 samples as follows: 4 10000 * Sum(Errors(i)/Frames(i)) i=1 Errors(i) = rptrMonitorPortTotalErrors(i) - rptrMonitorPortTotalErrors(i-1) Frames(i) = rptrMonitorPortReadableFrames(i) - rptrMonitorPortReadableFrames(i-1) The value is an integer number of errors per 10,000 packets received by this repeater. A default threshold exists on this average so that if a calculated average exceeds 200 (i.e . 2% of frames are in error) a trap will be sent to the management station. Further traps will not be sent until the average drops to below 100 (i.e. 1% of frames are in error) . A particular device may provide a means of changing the number of samples, the averaging period and threshold if it so wishes." ::= {mrmMonitorRepEntry 29} mrmMonCardPackage OBJECT IDENTIFIER ::= {mrmMonitorPackage 2} -- -- MRM Monitor Card Table -- mrmMonitorCardTable OBJECT-TYPE SYNTAX SEQUENCE OF MrmMonitorCardEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains parameters about the various repeater cards within the chassis. The table is indexed using the 'serviceIndex' for the repeater and the slot number within that repeater." ::= {mrmMonCardPackage 1} mrmMonitorCardEntry OBJECT-TYPE SYNTAX MrmMonitorCardEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Status information and control variables for the ports on a single card." INDEX {mrmMonCardServiceId, mrmMonCardIndex} ::= {mrmMonitorCardTable 1} MrmMonitorCardEntry ::= SEQUENCE { mrmMonCardServiceId INTEGER, mrmMonCardIndex INTEGER, mrmMonCardReadableFrames Counter, mrmMonCardUnicastFrames Counter, mrmMonCardMulticastFrames Counter, mrmMonCardBroadcastFrames Counter, mrmMonCardReadableOctets Counter, mrmMonCardUnicastOctets Counter, mrmMonCardMulticastOctets Counter, mrmMonCardBroadcastOctets Counter, mrmMonCardFCSErrors Counter, mrmMonCardAlignmentErrors Counter, mrmMonCardFrameTooLongs Counter, mrmMonCardShortEvents Counter, mrmMonCardRunts Counter, mrmMonCardLateEvents Counter, mrmMonCardVeryLongEvents Counter, mrmMonCardDataRateMismatches Counter, mrmMonCardAutoPartitions Counter, mrmMonCardTotalErrors Counter, mrmMonCardBound0 Counter, mrmMonCardBound1 Counter, mrmMonCardBound2 Counter, mrmMonCardBound3 Counter, mrmMonCardBound4 Counter, mrmMonCardBound5 Counter, mrmMonCardClearCounters INTEGER, mrmMonCardBandwidthUsed Counter, mrmMonCardErrorsPer10000Packets Counter } mrmMonCardServiceId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This parameter is used as the first of two indices in this table. A modular chassis contains potentially many repeater services. Each repeater service contains a number of cards (or groups). In order to uniquely identify a port it is necessary to specify both the repeater service and the card within that repeater." ::= {mrmMonitorCardEntry 1} mrmMonCardIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This is the second part of the key on this table. Having selected one of the repeaters within the chassis it is necessary to identify the card within that repeater." ::= {mrmMonitorCardEntry 2} mrmMonCardReadableFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one for each frame whose OctetCount is greater than or equal to minFrameSize and less than or equal to maxFrameSize and for which FCSError is not asserted that is received for any port on this card." ::= {mrmMonitorCardEntry 3} mrmMonCardUnicastFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one for each readable frame seen by the Card that is addressed to a unicast (non Card) address." ::= {mrmMonitorCardEntry 4} mrmMonCardMulticastFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one for each readable frame seen by the Card that is addressed to a multicast (non broadcast) address." ::= {mrmMonitorCardEntry 5} mrmMonCardBroadcastFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one for each readable frame seen by the Card that is addressed to the broadcast address ffffffffffff." ::= {mrmMonitorCardEntry 6} mrmMonCardReadableOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by the octet count for each readable frame received by any port on this card." ::= {mrmMonitorCardEntry 7} mrmMonCardUnicastOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object is the number of octets contained in valid frames that have been received on this port in which the destination field was a unicast address. The approximate minimum time for rollover of this counter is 58 minutes." ::= {mrmMonitorCardEntry 8} mrmMonCardMulticastOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object is the number of octets contained in valid frames that have been received on this port in which the destination was a multicast address. The approximate minimum time for rollover of this counter is 58 minutes." ::= {mrmMonitorCardEntry 9} mrmMonCardBroadcastOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object is the number of octets contained in valid frames that have been received on this port in which the destination was the broadcast address ffffffffffff. By attaching a gauge to this counter one can monitor the port for broadcast storms. Action can then be taken to automatically recover network normal operation. The approximate minimum time for rollover of this counter is 58 minutes." ::= {mrmMonitorCardEntry 10} mrmMonCardFCSErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one for each frame with an FCS error that does not have a framing error and which is of legal frame size." ::= {mrmMonitorCardEntry 11} mrmMonCardAlignmentErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one for each frame with an FCS error that does have a framing error and which is of legal frame size ." ::= {mrmMonitorCardEntry 12} mrmMonCardFrameTooLongs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one for each frame whose octet count is greater than the max frame size that is received by the repeater." ::= {mrmMonitorCardEntry 13} mrmMonCardShortEvents OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one for each carrier event whose duration is less than short event max time that is detected." ::= {mrmMonitorCardEntry 14} mrmMonCardRunts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one for each carrier event whose duration is greater than short event max time and less than valid packet min time and which does not suffer a collision." ::= {mrmMonitorCardEntry 15} mrmMonCardLateEvents OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one each time a collisions occurs after valid packet min time, a late event is counted as both a collision and as a late event." ::= {mrmMonitorCardEntry 16} mrmMonCardVeryLongEvents OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one each time a carrier event occurs whose duration is greater than the MAU Jabber Lockup Protection time." ::= {mrmMonitorCardEntry 17} mrmMonCardDataRateMismatches OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one each time a packet has been received with the data rate detectably mismatched from the local frequency." ::= {mrmMonitorCardEntry 18} mrmMonCardAutoPartitions OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one each time the repeater has automatically partitioned any port." ::= {mrmMonitorCardEntry 19} mrmMonCardTotalErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of errors which have occurred on all ports of this card. This counter is the summation of the values of other error counters (for each port), namely: FCS Errors, Alignment Errors, Frames Too Long, Short Events, Late Events, Very Long Events, Data Rate Mismatches. This counter is redundant in the sense that it is the summation of information already available through other objects. However, it is included specifically because the regular retrieval of this object as a means of tracking the health of a port provides a considerable optimization of network management traffic over the otherwise necessary retrieval of the summed counters." ::= {mrmMonitorCardEntry 20} mrmMonCardBound0 OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object is a summation of the number of frames (including error frames) with a length of 64 octets which were received by each port on this card." ::= {mrmMonitorCardEntry 21} mrmMonCardBound1 OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object is a summation of the number of frames (including error frames) with a length of between 65 and 127 octets inclusive which were received by each port on this card." ::= {mrmMonitorCardEntry 22} mrmMonCardBound2 OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object is a summation of the number of frames (including error frames) with a length of between 128 and 255 octets inclusive which were received by each port on this card." ::= {mrmMonitorCardEntry 23} mrmMonCardBound3 OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object is a summation of the number of frames (including error frames) with a length of between 256 and 511 octets inclusive which were received by each port on this card." ::= {mrmMonitorCardEntry 24} mrmMonCardBound4 OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object is a summation of the number of frames (including error frames) with a length of between 512 and 1023 octets inclusive which were received by each port on this card." ::= {mrmMonitorCardEntry 25} mrmMonCardBound5 OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object is a summation of the number of frames (including error frames) with a length of between 1024 and 1518 octets inclusive which were received by each port on this card." ::= {mrmMonitorCardEntry 26} mrmMonCardClearCounters OBJECT-TYPE SYNTAX INTEGER { noChangeCounters (1), clearCounters (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute allows all counters on this Card to be cleared. If this object is read then it will return noChangeCounters(1)." ::= {mrmMonitorCardEntry 27} mrmMonCardBandwidthUsed OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This is a high level 'smart MIB' object. This object provides a running average of the bandwidth in use. This value is calculated locally on the agent and so does not require processor bandwidth from the management station or occupy valuable network bandwidth communicating with that station. By default an agent supporting this parameter will exhibit the following characteristics: 1) The parameter will be recalculated at approx 15 second intervals 2) Every calculation period the device will read the value of rptrMonitorGroupTotalOctets. 3) The calculation will be performed on the most recent 4 samples as follows: 4 Sum(sample(i)/(time(i) * K)) * 100/4 i=1 Sample(i) is rptrMonitorGroupTotalOctets(i) - rptrMonitorGroupTotalOctets(i-1) time(i) is the time between sample(i-1) and sample(i) K is the max bytes per unit time (i.e. the available bandwidth K depends on the ring speed. The value is expressed as a percentage. A default threshold exists on this average so that if a calculated average exceeds 15% a trap will be sent to the management station. Further traps will not be sent until the average drops to below 10%. A particular device may provide a means of changing the number of samples, the averaging period, threshold and threshold action if it so wishes." ::= {mrmMonitorCardEntry 28} mrmMonCardErrorsPer10000Packets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This is a high level 'smart MIB' object. This object provides a running average of the bandwidth in use. The value of this value is calculated locally on the agent and so does not require processor bandwidth from a management station or occupy valuable network bandwidth communicating with that station. By default an agent supporting this parameter will exhibit the following behaviour: 1) The parameter will be recalculated at approx 15 second intervals. 2) Every calculation period the device will read the value of rptrMonitorGroupTotalErrors and rptrMonitorGroupTotalFrames. 3) The calculation will be performed on the most recent 4 samples as follows: 4 10000 * Sum(Errors(i)/Frames(i)) i=1 Errors(i) = rptrMonitorGroupTotalErrors(i) - rptrMonitorGroupTotalErrors(i-1) Frames(i) = rptrMonitorGroupTotalFrames(i) - rptrMonitorGroupTotalFrames(i-1) The value is an integer number of errors per 10,000 packets received by this repeater. A default threshold exists on this average so that if a calculated average exceeds 200 (i.e . 2% of frames are in error) a trap will be sent to the management station. Further traps will not be sent until the average drops to below 100 (i.e. 1% of frames are in error) . A particular device may provide a means of changing the number of samples, the averaging period and threshold if it so wishes." ::= {mrmMonitorCardEntry 29} mrmMonPortPackage OBJECT IDENTIFIER ::= {mrmMonitorPackage 3} -- -- MRM Monitor Port Table -- mrmMonitorPortTable OBJECT-TYPE SYNTAX SEQUENCE OF MrmMonitorPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of performance and error statistics for the ports." ::= {mrmMonPortPackage 1} mrmMonitorPortEntry OBJECT-TYPE SYNTAX MrmMonitorPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Performance and error statistics for a single port." INDEX {mrmMonPortServiceId, mrmMonPortCardIndex, mrmMonPortIndex} ::= {mrmMonitorPortTable 1} MrmMonitorPortEntry ::= SEQUENCE { mrmMonPortServiceId INTEGER, mrmMonPortCardIndex INTEGER, mrmMonPortIndex INTEGER, mrmMonPortReadableFrames Counter, mrmMonPortUnicastFrames Counter, mrmMonPortMulticastFrames Counter, mrmMonPortBroadcastFrames Counter, mrmMonPortReadableOctets Counter, mrmMonPortUnicastOctets Counter, mrmMonPortMulticastOctets Counter, mrmMonPortBroadcastOctets Counter, mrmMonPortFCSErrors Counter, mrmMonPortAlignmentErrors Counter, mrmMonPortFrameTooLongs Counter, mrmMonPortShortEvents Counter, mrmMonPortRunts Counter, mrmMonPortCollisions Counter, mrmMonPortLateEvents Counter, mrmMonPortVeryLongEvents Counter, mrmMonPortDataRateMismatches Counter, mrmMonPortAutoPartitions Counter, mrmMonPortTotalErrors Counter, mrmMonPortBound0 Counter, mrmMonPortBound1 Counter, mrmMonPortBound2 Counter, mrmMonPortBound3 Counter, mrmMonPortBound4 Counter, mrmMonPortBound5 Counter, mrmMonPortBandwidthUsed Counter, mrmMonPortErrorsPer10000Packets Counter, mrmMonPortClearCounters INTEGER, mrmMonPortLastAddress OCTET STRING , mrmMonPortAddressChanges Counter } mrmMonPortServiceId OBJECT-TYPE SYNTAX INTEGER (1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "This parameter selects one of the repeaters within the chassis. This forms the first, most significant index column. Having selected a repeater one must select a card then port within that repeater." ::= {mrmMonitorPortEntry 1} mrmMonPortCardIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This attribute uniquely identifies this Card within the repeater, it is part of the index for the port table." ::= {mrmMonitorPortEntry 2} mrmMonPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This attribute uniquely identifies this port within the Card, it is part of the index for the port table." ::= {mrmMonitorPortEntry 3} mrmMonPortReadableFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object is the number of frames of valid frame length that have been received on this port. This counter is incremented by one for each frame received on this port whose OctetCount is greater than or equal to minFrameSize and less than or equal to maxFrameSize (Ref: IEEE 802.3 Std, 4.4.2.1) and for which the FCSError and CollisionEvent signals are not asserted. This statistic provides one of the parameters necessary for obtaining the packet error rate. The approximate minimum time for rollover of this counter is 80 hours." ::= {mrmMonitorPortEntry 4} mrmMonPortUnicastFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one for each readable frame seen by the Card that is addressed to a unicast (non Card) address." ::= {mrmMonitorPortEntry 5} mrmMonPortMulticastFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one for each readable frame seen by the Card that is addressed to a multicast (non broadcast) address." ::= {mrmMonitorPortEntry 6} mrmMonPortBroadcastFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one for each readable frame seen by the Card that is addressed to the broadcast address." ::= {mrmMonitorPortEntry 7} mrmMonPortReadableOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object is the number of octets contained in valid frames that have been received on this port. This counter is incremented by OctetCount for each frame received on this port which has been determined to be a readable frame. This statistic provides an indicator of the total data transferred. The approximate minimum time for rollover of this counter is 58 minutes." ::= {mrmMonitorPortEntry 8} mrmMonPortUnicastOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object is the number of octets contained in valid frames that have been received on this port in which the destination field was a unicast address. The approximate minimum time for rollover of this counter is 58 minutes." ::= {mrmMonitorPortEntry 9} mrmMonPortMulticastOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object is the number of octets contained in valid frames that have been received on this port in which the destination was a multicast address. The approximate minimum time for rollover of this counter is 58 minutes." ::= {mrmMonitorPortEntry 10} mrmMonPortBroadcastOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object is the number of octets contained in valid frames that have been received on this port in which the destination was the broadcast address ffffffffffff. By attaching a gauge to this counter one can monitor the port for broadcast storms. Action can then be taken to automatically recover network normal operation. The approximate minimum time for rollover of this counter is 58 minutes." ::= {mrmMonitorPortEntry 11} mrmMonPortFCSErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one for each frame received on this port with the FCSError signal asserted and the FramingError and CollisionEvent signals deasserted and whose OctetCount is greater than or equal to minFrameSize and less than or equal to maxFrameSize (Ref: 4.4.2.1, IEEE 802.3 Std). The approximate minimum time for rollover of this counter is 80 hours." ::= {mrmMonitorPortEntry 12} mrmMonPortAlignmentErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one for each frame received on this port with the FCSError and FramingError signals asserted and CollisionEvent signal deasserted and whose OctetCount is greater than or equal to minFrameSize and less than or equal to maxFrameSize ( Ref: IEEE 802.3 Std, 4.4.2.1). If rptrMonitorPortAlignmentErrors is incremented then the rptrMonitorPortFCSErrors Counter shall not be incremented for the same frame. The approximate minimum time for rollover of this counter is 80 hours." ::= {mrmMonitorPortEntry 13} mrmMonPortFrameTooLongs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one for each frame received on this port whose OctetCount is greater than maxFrameSize (Ref: 4.4.2.1, IEEE 802.3 Std). If this parameter is incremented then neither the alignment error nor the FCS error counters shall be incremented for the frame. The approximate minimum time for rollover of this counter is 61 days." ::= {mrmMonitorPortEntry 14} mrmMonPortShortEvents OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one for each CarrierEvent on this port with ActivityDuration less than ShortEventMaxTime. ShortEventMaxTime is greater than 74 bit times and less than 82 bit times. ShortEventMaxTime has tolerances included to provide for circuit losses between a conformance test point at the AUI and the measurement point within the state machine. Note: shortEvents may indicate externally generated noise hits which will cause the repeater to transmit Runts to its other ports, or propagate a collision (which may be late) back to the transmitting DTE and damaged frames to the rest of the network. The approximate minimum time for rollover of this counter is 16 hours." ::= {mrmMonitorPortEntry 15} mrmMonPortRunts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one for each CarrierEvent on this port that meets one of the following two conditions. Only one test need be made. a) The ActivityDuration is greater than ShortEventMaxTime and less than ValidPacketMinTime and the CollisionEvent signal is deasserted. b) The OctetCount is less than 64, the ActivityDuration is greater than ShortEventMaxTime and the CollisionEvent signal is deasserted. ValidPacketMinTime is greater than or equal to 552 bit times and less than 565 bit times. An event whose length is greater than 74 bit times but less than 82 bit times shall increment either the shortEvents counter or the runts counter but not both. A CarrierEvent greater than or equal to 552 bit times but less than 565 bit times may or may not be counted as a runt. ValidPacketMinTime has tolerances included to provide for circuit losses between a conformance test point at the AUI and the measurement point within the state machine. Runts usually indicate collision fragments, a normal network event. In certain situations associated with large diameter networks a percentage of runts may exceed ValidPacketMinTime. The approximate minimum time for rollover of this counter is 16 hours." ::= {mrmMonitorPortEntry 16} mrmMonPortCollisions OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one each time a collision is detected on this port or when the CollisionEvent signal is asserted on this port. The approximate minimum time for rollover of this counter is 16 hours." ::= {mrmMonitorPortEntry 17} mrmMonPortLateEvents OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one for each CarrierEvent on this port in which the CollIn(X) variable transitions to the value SQE (Ref: 9.6.6.2, IEEE 802.3 Std) while the ActivityDuration is greater than the LateEventThreshold. Such a CarrierEvent is counted twice, as both a collision and as a lateEvent. The LateEventThreshold is greater than 480 bit times and less than 565 bit times. LateEventThreshold has tolerances included to permit an implementation to build a single threshold to serve as both the LateEventThreshold and ValidPacketMinTime threshold. The approximate minimum time for rollover of this counter is 81 hours." ::= {mrmMonitorPortEntry 18} mrmMonPortVeryLongEvents OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one for each CarrierEvent on this port whose ActivityDuration is greater than the MAU Jabber Lockup Protection timer TW3 (Ref: 9.6.1 & 9. 6.5, IEEE 802.3 Std). Other counters may be incremented as appropriate." ::= {mrmMonitorPortEntry 19} mrmMonPortDataRateMismatches OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one for each frame received on this port that meets all of the following conditions: a) The CollisionEvent signal is not asserted. b) The ActivityDuration is greater than ValidPacketMinTime. c) The frequency (data rate) is detectably mismatched from the local transmit frequency. The exact degree of mismatch is vendor specific and is to be defined by the vendor for conformance testing. When this event occurs, other counters whose increment conditions were satisfied may or may not also be incremented, at the implementor's discretion. Whether or not the repeater was able to maintain data integrity is beyond the scope of this standard." ::= {mrmMonitorPortEntry 20} mrmMonPortAutoPartitions OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one for each time the repeater has automatically partitioned this port. The conditions that cause port partitioning are specified in the partition state machine in Section 9 [IEEE 802.3 Std]. They are not differentiated here." ::= {mrmMonitorPortEntry 21} mrmMonPortTotalErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of errors which have occurred on this port. This counter is the summation of the values of other error counters (for the same port), namely: FCS Errors, Alignment Errors, Frames Too Long, Short Events, Late Events, Very Long Events, Data Rate Mismatches. This counter is redundant in the sense that it is the summation of information already available through other objects. However, it is included specifically because the regular retrieval of this object as a means of tracking the health of a port provides a considerable optimization of network management traffic over the otherwise necessary retrieval of the summed counters." ::= {mrmMonitorPortEntry 22} mrmMonPortBound0 OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object is the number of frames (including error frames) with a length of 64 octets which were received on this port." ::= {mrmMonitorPortEntry 23} mrmMonPortBound1 OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object is the number of frames (including error frames) with a length of between 65 and 127 octets inclusive which were received on this port." ::= {mrmMonitorPortEntry 24} mrmMonPortBound2 OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object is the number of frames (including error frames) with a length of between 128 and 255 octets inclusive which were received on this port." ::= {mrmMonitorPortEntry 25} mrmMonPortBound3 OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object is the number of frames (including error frames) with a length of between 256 and 511 octets inclusive which were received on this port." ::= {mrmMonitorPortEntry 26} mrmMonPortBound4 OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object is the number of frames (including error frames) with a length of between 512 and 1023 octets inclusive which were received on this port." ::= {mrmMonitorPortEntry 27} mrmMonPortBound5 OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object is the number of frames (including error frames) with a length of between 1024 and 1518 octets inclusive which were received on this port." ::= {mrmMonitorPortEntry 28} mrmMonPortBandwidthUsed OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This is a high level 'smart MIB' object. This object provides a running average of the bandwidth in use. This value is calculated locally on the agent and so does not require processor bandwidth from the management station or occupy valuable network bandwidth communicating with that station. By default an agent supporting this parameter will exhibit the following characteristics: 1) The parameter will be recalculated at approx 15 second intervals 2) Every calculation period the device will read the value of mrmMonPortReadableOctets. 3) The calculation will be performed on the most recent 4 samples as follows: 4 Sum(sample(i)/(time(i) * K)) * 100/4 i=1 Sample(i) is mrmMonPortReadableOctets(i) - mrmMonPortReadableOctets(i-1) time(i) is the time between sample(i-1) and sample(i) K is the max bytes per unit time (i.e. the available bandwidth K depends on the ring speed. The value is expressed as a percentage. A default threshold exists on this average so that if a calculated average exceeds 15% a trap will be sent to the management station. Further traps will not be sent until the average drops to below 10%. A particular device may provide a means of changing the number of samples, the averaging period, threshold and threshold action if it so wishes." ::= {mrmMonitorPortEntry 29} mrmMonPortErrorsPer10000Packets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This is a high level 'smart MIB' object. This object provides a running average of the number of errors per 10000 packets. This is an error rate, and is calculated over the number of packets received in the sample periods, and not on every 10000 packets. This value is calculated locally on the agent and so does not require processor bandwidth from a management station or occupy valuable network bandwidth communicating with that station. By default an agent supporting this parameter will exhibit the following behaviour: 1) The parameter will be recalculated at approx 15 second intervals. 2) Every calculation period the device will read the value of mrmMonPortTotalErrors and mrmMonPortReadableFrames. 3) The calculation will be performed on the most recent 4 samples as follows: 4 Sum(Errors(i)/Frames(i)) * 10000/4 i=1 Errors(i) = mrmMonPortTotalErrors(i) - mrmMonPortTotalErrors(i-1) Frames(i) = mrmMonPortReadableFrames(i) - mrmMonPortReadableFrames(i-1) The value is an integer number of errors per 10,000 packets received by this repeater. A default threshold exists on this average so that if a calculated average exceeds 200 (i.e . 2% of frames are in error) a trap will be sent to the management station. Further traps will not be sent until the average drops to below 100 (i.e. 1% of frames are in error) . A particular device may provide a means of changing the number of samples, the averaging period and threshold if it so wishes." ::= {mrmMonitorPortEntry 30} mrmMonPortClearCounters OBJECT-TYPE SYNTAX INTEGER { noChangeCounters (1), clearCounters (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute allows all counters on this Port to be cleared. If read this object will return noChangeCounters(1)." ::= {mrmMonitorPortEntry 31} mrmMonPortLastAddress OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "This is the last MAC address seen on this port." ::= {mrmMonitorPortEntry 32} mrmMonPortAddressChanges OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This is a count of the number of times the MAC address on this port has changed. A high number of changes indicates this is either an inter-repeater link or a multi-drop segment." ::= {mrmMonitorPortEntry 33} mrmMonRepeaterSmartPackage OBJECT IDENTIFIER ::= {mrmMonitorPackage 5} -- -- New Smart Packages for Repeater, Card and Port -- mrmMonRepeaterTrafficLevel OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This is a smart MIB object which is used internally by the agent to provide a running average of the bandwidth in use. It should not be accessed by a management station and is used by the logic which calculates the value of its associated object 'mrmMonRepeater BandwidthUsed'. See 'mrmMonRepeaterBandwidthUsed' for a description of how the bandwidth used is calculated." ::= {mrmMonRepeaterSmartPackage 1} mrmMonRepeaterErrorFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This is a smart MIB object which is used internally by the agent to provide a running average of the error rate. It should not be accessed by a management station and is used by the logic which calculates the value of its associated object 'mrmMonRepeaterErrorsP er10000Packets'. See 'mrmMonRepeaterErrorsPer10000Packets' for a description of how the error rate is calculated." ::= {mrmMonRepeaterSmartPackage 2} mrmMonCardSmartPackage OBJECT IDENTIFIER ::= {mrmMonitorPackage 6} mrmMonCardTrafficLevel OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This is a smart MIB object which is used internally by the agent to provide a running average of the bandwidth in use. It should not be accessed by a management station and is used by the logic which calculates the value of its associated object 'mrmMonCardBand widthUsed'. See 'mrmMonCardBandwidthUsed' for a description of how the bandwidth used is calculated." ::= {mrmMonCardSmartPackage 1} mrmMonCardErrorFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This is a smart MIB object which is used internally by the agent to provide a running average of the error rate. It should not be accessed by a management station and is used by the logic which calculates the value of its associated object 'mrmMonCardErrorsPer10 000Packets'. See 'mrmMonCardErrorsPer10000Packets' for a description of how the error rate is calculated." ::= {mrmMonCardSmartPackage 2} mrmMonPortSmartPackage OBJECT IDENTIFIER ::= {mrmMonitorPackage 7} mrmMonPortTrafficLevel OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This is a smart MIB object which is used internally by the agent to provide a running average of the bandwidth in use. It should not be accessed by a management station and is used by the logic which calculates the value of its associated object 'mrmMonPortBand widthUsed'. See 'mrmMonPortBandwidthUsed' for a description of how the bandwidth used is calculated." ::= {mrmMonPortSmartPackage 1} mrmMonPortErrorFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This is a smart MIB object which is used internally by the agent to provide a running average of the error rate. It should not be accessed by a management station and is used by the logic which calculates the value of its associated object 'mrmMonPortErrorsPer10 000Packets'. See 'mrmMonPortErrorsPer10000Packets' for a description of how the error rate is calculated." ::= {mrmMonPortSmartPackage 2} -- ********************************************************************** -- Define enterprise repeater traps. Rules for mrm traps are that any -- varbind must be from a table in which the first qualifier on the -- object id is the service identifier of the 'thing' causing the trap. -- ********************************************************************** repPartitionStateChange TRAP-TYPE ENTERPRISE a3Com VARIABLES {mrmPortAutoPartitionState } DESCRIPTION "This trap is sent when the partition state of a port changes. The trap is accompanied by the new partition state of the port." ::= 38 repLinkStateChange TRAP-TYPE ENTERPRISE a3Com VARIABLES {mrmPortLinkState } DESCRIPTION "This trap is sent when the link state of a port changes. The var-bind identifies which port has changed state and what the new state of that port is." ::= 39 repAdminStateChange TRAP-TYPE ENTERPRISE a3Com VARIABLES {mrmPortAdminStatus } DESCRIPTION "This trap is only sent when the administration state of a port is changed by a gauge. It is not sent if a user initiates a state change via SNMP, Telnet or the V.24 terminal interface." ::= 40 repPortTopUsage TRAP-TYPE ENTERPRISE a3Com VARIABLES {mrmMonPortBandwidthUsed, gaugeThresholdLevel, gaugeSamplePeriod, gaugeSamplesPerAverage } DESCRIPTION "This trap is sent when the port bandwidth used exceeds the defined threshold. This threshold is by default 15%, although this may have been changed on a particular device." ::= 41 repPortErrors TRAP-TYPE ENTERPRISE a3Com VARIABLES {mrmMonPortErrorsPer10000Packets, gaugeThresholdLevel, gaugeSamplePeriod, gaugeSamplesPerAverage } DESCRIPTION "This trap is sent when the errors per packet exceeds the the defined threshold." ::= 42 dudUnauthorisedDevice TRAP-TYPE ENTERPRISE a3Com VARIABLES { mrmPortDUDAction } DESCRIPTION "This trap is sent when an unrecognised MAC address appears on the port. It is only sent if DUD is set on the port." ::= 66 repRepTopUsage TRAP-TYPE ENTERPRISE a3Com VARIABLES { mrmMonRepBandwidthUsed, gaugeThresholdLevel, gaugeSamplePeriod, gaugeSamplesPerAverage } DESCRIPTION "This trap is sent when the repeater bandwidth used exceeds the defined threshold. This threshold is by default 15%, although this may have been changed on a particular device." ::= 67 repRepErrors TRAP-TYPE ENTERPRISE a3Com VARIABLES { mrmMonRepErrorsPer10000Packets, gaugeThresholdLevel, gaugeSamplePeriod, gaugeSamplesPerAverage } DESCRIPTION "This trap is sent when the repeater errors per packet exceeds the defined threshold." ::= 68 repCardTopUsage TRAP-TYPE ENTERPRISE a3Com VARIABLES { mrmMonCardBandwidthUsed, gaugeThresholdLevel, gaugeSamplePeriod, gaugeSamplesPerAverage } DESCRIPTION "This trap is sent when the card bandwidth used exceeds the defined threshold. This threshold is by default 15%, although this may have been changed on a particular device." ::= 69 repCardErrors TRAP-TYPE ENTERPRISE a3Com VARIABLES { mrmMonCardErrorsPer10000Packets, gaugeThresholdLevel, gaugeSamplePeriod, gaugeSamplesPerAverage } DESCRIPTION "This trap is sent when the errors per packet exceeds the defined threshold." ::= 70 END -- -- SECURITY MIB -- A3COMMG003-PORT-SECURITY DEFINITIONS ::= BEGIN IMPORTS securePort FROM A3COM0004-GENERIC OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 mrmPortAdminStatus FROM A3COMMG005-MRM-MIB rptrPortAdminStatus FROM SNMP-REPEATER-MIB ; securePortTable OBJECT-TYPE SYNTAX SEQUENCE OF SecurePortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table defines the security status of each secure port. Each port can have a number of authorised MAC addresses, and these are stored in the secureAddressTable." ::= {securePort 1} securePortEntry OBJECT-TYPE SYNTAX SecurePortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "There is a row in this table for each secure port, and allows repeater ports to be configured for security on a per port basis. It is indexed using the objects secureSlotIndex and securePortIndex." INDEX {secureSlotIndex, securePortIndex} ::= {securePortTable 1} SecurePortEntry ::= SEQUENCE { secureSlotIndex INTEGER, securePortIndex INTEGER, securePortMode INTEGER, secureNeedToKnowMode INTEGER, secureIntrusionAction INTEGER, secureNumberAddresses INTEGER, secureNumberAddressesStored INTEGER, secureMaximumAddresses INTEGER } secureSlotIndex OBJECT-TYPE SYNTAX INTEGER (1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "The slot or unit number of the secure port. This is the first index into the securePortTable." ::= {securePortEntry 1} securePortIndex OBJECT-TYPE SYNTAX INTEGER (1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "The port number of the secure port. This is the second index into the securePortTable." ::= {securePortEntry 2} securePortMode OBJECT-TYPE SYNTAX INTEGER { noRestrictions (1), continuousLearning (2), autoLearn (3), secure (4) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the learning and security modes of the port. See secureNeedToKnowMode and secureIntrusionAction to configure Need To Know and Intrusion Action on each port. (When in a learning mode, secureNumberAddresses determines the maximum number of addresses that can be learned on the port. This is set by the user.) noRestrictions(1) All learning and security are disabled. continuousLearning(2) Addresses are learned continually. If more addresses are learned than are permitted on the port, then one of the older entries will be aged out. Need To Know and Intrusion Action depends on secureNeedToKnowMode and secureIntrusionAction respectively. autoLearn(3) All addresses for this port are deleted, and then addresses are learned up to the number permitted. securePortMode is then set to secure. Need To Know and Intrusion Action depends on secureNeedToKnowMode and secureIntrusionAction respectively. secure(4) Learning is disabled. Need To Know and Intrusion Action depends on secureNeedToKnowMode and secureIntrusionAction respectively. The secureAddrressLearned trap is sent whenever a station has been learned. The secureViolation trap is sent whenever a packet is received from an unauthorised station." ::= {securePortEntry 3} secureNeedToKnowMode OBJECT-TYPE SYNTAX INTEGER { notAvailable (1), disabled (2), needToKnowOnly (3), needToKnowWithBroadcastsAllowed (4), needToKnowWithMulticastsAllowed (5), permanentNeedToKnowOnly (6), permanentNeedToKnowWithBroadcastsAllowed (7), permanentNeedToKnowWithMulticastsAllowed (8) } ACCESS read-write STATUS mandatory DESCRIPTION "Attribute to determine which frames are to be forwarded to this port intact. 1 - Need To Know is not available. 2 - All frames. 3 - Frames addressed to the authorised devices only. 4 - Frames addressed to the authorised devices, plus all broadcast frames. 5 - Frames addressed to the authorised devices, plus all broadcast and multicast frames. 6 - As 3 and cannot be changed. 7 - As 4 and cannot be changed. 8 - As 5 and cannot be changed. If this object returns 1,6,7 or 8, it means that the Need To Know configuration cannot be changed, and any attempt to write to this object will cause an error." ::= {securePortEntry 4} secureIntrusionAction OBJECT-TYPE SYNTAX INTEGER { notAvailable (1), noAction (2), disablePort (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Attribute to determine the action if an unauthorised device tranmsits on this port." ::= {securePortEntry 5} -- -- The following 3 objects are used to allow multiple MAC addresses to be -- assigned to the port. -- secureNumberAddresses OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The maximum number of addresses that the port can learn or store. Reducing this number may cause some addresses to be deleted. This value is set by the user and cannot be automatically changed by the agent." ::= {securePortEntry 6} secureNumberAddressesStored OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of addresses that are currently in the AddressTable for this port. If this object has the same value as secureNumberAddresses, then no more addresses can be authorised on this port." ::= {securePortEntry 7} secureMaximumAddresses OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This indicates the maximum value that secureNumberAddresses can be set to. It is dependent on the resources available so may change, eg. if resources are shared between ports, then this value can both increase and decrease. This object must be read before setting secureNumberAddresses." ::= {securePortEntry 8} -- -- SECURE ADDRESS TABLE -- secureAddressTable OBJECT-TYPE SYNTAX SEQUENCE OF SecureAddressEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table which stores the MAC addresses assigned to each port. Addresses will normally defined as authorised, and describe the devices which are permitted to transmit and receive on the corresponding port. This table can be written to by the agent as well as the management station." ::= {securePort 2} secureAddressEntry OBJECT-TYPE SYNTAX SecureAddressEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table allows multiple addresses to be assigned to each secure port. It is indexed using the objects secureAddrressSlotIndex, secureAddrressPortIndex and secPortAddress." INDEX { secureAddrSlotIndex, secureAddrPortIndex, secureAddrMACAddress } ::= {secureAddressTable 1} SecureAddressEntry ::= SEQUENCE { secureAddrSlotIndex INTEGER, secureAddrPortIndex INTEGER, secureAddrMACAddress OCTET STRING, secureAddrRowStatus INTEGER } secureAddrSlotIndex OBJECT-TYPE SYNTAX INTEGER (1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "The slot or unit number of the secure port. This is the first index into the secureAddressTable." ::= {secureAddressEntry 1} secureAddrPortIndex OBJECT-TYPE SYNTAX INTEGER (1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "The port number of the secure port. This is the second index into the secureAddressTable." ::= {secureAddressEntry 2} secureAddrMACAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(6)) ACCESS read-only STATUS mandatory DESCRIPTION "The MAC address of a station assigned to this port. This is the third index into the secureAddressTable." ::= {secureAddressEntry 3} secureAddrRowStatus OBJECT-TYPE SYNTAX INTEGER { active (1), notInService (2), notReady (3), createAndGo (4), createAndWait (5), destroy (6) } ACCESS read-write STATUS mandatory DESCRIPTION "This manages the creation and deletion or rows, and shows the current status of the indexed MAC address. This object has the following values. 1 - The indexed MAC address is authorised on this port. 2 - The indexed MAC address is not authorised on this port. 3 - Not applicable. (This value indicates an incomplete row.) 4 - Assign a new MAC address to the port and authorise immediately. 5 - Assign a new MAC address to the port, but do not authorise until active(1) is written to this object. 6 - Delete this entry. When creating a new entry, index a new row and use createAndGo(4) or createAndWait(5). Some hardware will not allow the address to be unauthorised, and will automatically switch the row to active(1). When reading this object, only active(1) and notInService(2) will be returned. Only the values active(1) and destroy(6) will be allowed for an existing row, or createAndGo(4) and createAndWait(5) for a new row." ::= {secureAddressEntry 4} secureAddrressLearned TRAP-TYPE ENTERPRISE a3Com VARIABLES { secureAddrRowStatus } DESCRIPTION "This trap is sent when a new station has been learned. The slot and port on which the address was received are in the first and second index of secureAddrRowStatus, and the MAC address of the learned station is in the third index." ::= 71 secureViolation TRAP-TYPE ENTERPRISE a3Com VARIABLES { secureAddrRowStatus, mrmPortAdminStatus } DESCRIPTION "This trap is sent whenever a security violation has occured. The slot and port on which the violation occured are in the first and second index of secureAddrRowStatus, and the MAC address of the offending station is in the third index. mrmPortAdminStatus indicates if the port has been disabled because of the violation. The implementation may not send violation traps from the same port at intervals of less than 5 seconds." ::= 72 END -- -- The LinkSwitch Product Specific MIB -- A3COMMG004-LINKSWITCH DEFINITIONS ::= BEGIN IMPORTS linkSwitch1000-mib FROM A3Com-products-MIB DisplayString FROM RFC1213-MIB OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 ; -- ----------------------------------------------------------------------------- -- ----------------------------------------------------------------------------- -- Stack Group -- ----------------------------------------------------------------------------- linkSwitchStackGroup OBJECT IDENTIFIER ::= {linkSwitch1000-mib 1} -- ----------------------------------------------------------------------------- lsStackFwdingAction OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), fwdToDlink (2), fwdToAll (3) } ACCESS read-write STATUS deprecated DESCRIPTION "This object specifies what action a Perseus unit takes when it receives a packet with an unknown destination address. A unit can forward the packet to the downlink (if any) associated with the source port, or it can forward the packet to all its ports. When a Switch 1000 is set to fwdToAll(3), all existing backbone port selection logic and stored configuration is erased. Any attempt to define a downlink via the lsVLANtable will be rejected when this object is set to fwdToAll. The Switch 3000 and Desktop switch will reject any attempt to write to this object." ::= {linkSwitchStackGroup 1} lsStackFwdingMode OBJECT-TYPE SYNTAX INTEGER { fastForward(1), fragmentFree(2), storeAndForward(3), intelligent(4) } ACCESS read-write STATUS deprecated DESCRIPTION "This object controls whether cut-thru is enabled on the stack. Enabling cut-thru can help to minimise the delay experienced by packets before they are forwarded to their destination. Setting cut-thru to 'fastForward' causes frame forwarding to begin as soon as 32 bytes of the frame have been received. Setting it to 'fragmentFree' causes frame forwarding to begin when 64 bytes have been received. This is slower, but eliminates the risk of forwarding an illegally short frame to the destination port, however a valid length frame might still be forwarded even though it had a CRC error. Setting this object to 'storeAndForward' disables cut-thru completely, and frames will not be forwarded until they have been received in their entirety. When the mode is set to intelligent, the effective switching mode is set initially to fast forward. The switch then monitors the total error rate of frames received by the unit, and if it exceeds 18 error frames a second it changes the effective mode to store and forward. If the error rate then drops to zero the effective mode is restored to fast forward. Whatever forwarding mode is selected, cut-thru cannot operate if the destination port is currently involved in 'cut-thru' from another port. In this case the device will process the frame in store and forward mode." ::= {linkSwitchStackGroup 2} -- Configuration Group -- ----------------------------------------------------------------------------- linkSwitchConfigGroup OBJECT IDENTIFIER ::= {linkSwitch1000-mib 2} -- ----------------------------------------------------------------------------- -- ---------------------------------------------------------------------------- -- Configuration Port Table -- -- This table provides details of the configuration of a port on a -- LinkSwitch unit. -- ---------------------------------------------------------------------------- lsConfigPortTable OBJECT-TYPE SYNTAX SEQUENCE OF LsConfigPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table providing configuration information about a port on a LinkSwitch unit." ::= {linkSwitchConfigGroup 1} lsConfigPortEntry OBJECT-TYPE SYNTAX LsConfigPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Configuration options for a single port." INDEX {lsConPortUnitId,lsConPortId} ::= {lsConfigPortTable 1} LsConfigPortEntry ::= SEQUENCE { lsConPortUnitId INTEGER, lsConPortId INTEGER, lsConPortVLANid INTEGER, lsConPortIfIndex INTEGER, lsConPortMode INTEGER, lsConPortIFM INTEGER, lsConPortDiscardOnTx INTEGER, lsConPortPaceMode INTEGER, lsConPortVLANmode INTEGER, lsConPortModule INTEGER, lsConPortInterfaceType INTEGER, lsConPortFunction INTEGER, lsConPortVLANConfigMode INTEGER, lsConPortStpFastStart INTEGER } lsConPortUnitId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This attribute uniquely identifies a unit on a stack (or a card within a chassis) for which this table entry contains configuration information." ::= {lsConfigPortEntry 1} lsConPortId OBJECT-TYPE SYNTAX INTEGER (1..32) ACCESS read-only STATUS mandatory DESCRIPTION "This parameter specifies the second part of the index into this table. Having selected a unit/card, it is now necessary to identify the port on the unit/card." ::= {lsConfigPortEntry 2} lsConPortVLANid OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Unless VLAN multiplexing is enabled for the port by setting lsConPortVLANmode to multiplex(3), this attribute uniquely identifies the VLAN of which this port is a member. The attribute is used as an index for lsVLANtable to locate this port's VLAN entry. When VLAN multiplexing is enabled, the value of this object is always the identifier of the default VLAN." ::= {lsConfigPortEntry 3} lsConPortIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This attribute specifies the index into the ifTable, for the interface corresponding to this port." ::= {lsConfigPortEntry 4} lsConPortMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), halfDuplex (2), fullDuplex (3), useDefault(4), halfDuplex10Mbps (5), fullDuplex10Mbps (6), autoNegotiated (7) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the mode of the link between a port and its endstation. If the attribute is set to 'fullDuplex', frames are sent and received simultaneously without generating collisions on the segment. If the attribute is set to 'halfDuplex', the normal rules of ethernet apply. Ports not capable of auto-negotiation use only the first four values defined and operate at their native speed. Ports capable of auto-negotiation also use the last three values. For such ports, 'halfDuplex' and 'fullDuplex' imply 100Mbps operation. 'halfDuplex10Mbps' and 'fullDuplex10Mbps' set the duplex mode of the port as described above and also set the port to 10Mbps operation. 'autoNegotiated' puts the port into auto-negotiated mode, whereby the duplex mode and operating speed are dynamically determined by the capabilities of the endstation. When a unit is initialised to factory defaults, lsConPortMode is set to useDefault(4), and the actual setting for the port is decided by the value of lsConUnitDuplexMode." ::= {lsConfigPortEntry 5} lsConPortIFM OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), off (2), maxJams6 (3), maxJams7 (4), maxJams8 (5), maxJams9 (6), maxJams10 (7), maxJams11 (8), maxJams12 (9), maxJams13 (10) } ACCESS read-write STATUS mandatory DESCRIPTION "This object controls the Intelligent Flow Management for the port. It specifies what action a port takes whenever it is unable to receive a packet because its buffers are full. If it is set to off(1), the packet is dropped and no jam signal is transmitted. If the attribute is set to any of the values maxJams6(2) to maxJams13(10), a jam signal is applied to the segment attached to this port in order to backoff the transmitting station. This will be repeated a maximum of 6 to 13 times depending on the setting. If the port is then still unable to receive the packet it is dropped. Intelligent Flow Management should be disabled on ports which are connected to repeated segments." ::= {lsConfigPortEntry 6} lsConPortDiscardOnTx OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), off (2), on (3) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute indicates if the 'Discard-on-transmit' feature is enabled for frames originating at this port and going to any one of the other ports on a LinkSwitch unit. If this attribute is set to on(3), the unit will discard frames destined for any other port on a LinkSwitch unit, if that port's Tx FIFO is full. If this attribute is set to off(2), a frame will not be forwarded to another port until the Tx FIFO has space available for the frame." ::= {lsConfigPortEntry 7} lsConPortPaceMode OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), useDefault(2), normalEthernet(3), lowLatency(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the type of backoff algorithm used on a LinkSwitch port. A port can use the standard ethernet algorithm or, for PACE applications, it can be set into low latency mode. In this mode, the backoff algorithm is optimised to minimise the possibility of collisions. PACE mode can be set for the whole unit or for individual ports. When a unit is initialised to factory defaults, lsconPortPaceMode for every port is set to useDefault(2), and the actual setting for the port is decided by the value of lsConUnitPaceMode. The other values of this object allow the setting to be varied for individual ports." ::= {lsConfigPortEntry 8} lsConPortVLANmode OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), normal(2), multiplex(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This object controls whether or not this port is a `VLAN Trunk' which can can carry traffic for more than one VLAN. It is applicable only to 10Mbps and 100Mbps ethernet ports on point-to-point links, and to ATM ports. If this feature is not available for a particular port the value of lsConPortVLANmode is notApplicable(1). If a port is intrinsically capable of multiplexing traffic at all times (such as an ATM port), the mode will always read multiplex(3), and an attempt to set it to normal(2) will be rejected. When an ethernet port is set to multiplex(3), VLAN information is sent and received in conjunction with each frame. To work, the port must be connected to a port on another device which is also set to multiplex mode, otherwise all data transfer in both directions will fail. Care must be taken when setting this object that the port in the device at the end of the link furthest from the management station is set first. A port with lsConPortVLANmode set to normal(2) may act as a downlink for one and only one VLAN, and must be a member of that VLAN. A port with lsConPortVLANmode set to multiplex(3) may act as a downlink for all VLANs. If a port is a downlink for a VLAN when the mode is set to multiplex(3), all other VLANs will be forced to use the same downlink. Conversely, if the mode is changed back to normal(2) the port will remain the downlink for the default VLAN (1001) and all the other VLANs will be reconfigured to have no downlink." ::= {lsConfigPortEntry 9} lsConPortModule OBJECT-TYPE SYNTAX INTEGER { unknown (1), modularPort (2), notModularPort (3) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates whether the port is a modular port or not." ::= { lsConfigPortEntry 10 } lsConPortInterfaceType OBJECT-TYPE SYNTAX INTEGER { unknown(1), maleAUI(2), femaleAUI(3), thinCoax(4), twistedPair(5), unshieldedTP(6), fiber(7) } ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the type of electrical interface made available at the interface to the card for this port. The interface does not necessarily specify what the actual media to end station is." ::= { lsConfigPortEntry 11 } lsConPortFunction OBJECT-TYPE SYNTAX INTEGER { unknown(1), repeater(2), bridge(3), switch(4) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the function of the port." ::= { lsConfigPortEntry 12 } lsConPortVLANConfigMode OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), useDefault(2), portMode(3), autoSelect(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the vlan mode used whereby portMode requires the user to configure the port's vlan membership and autoSelectMode acquires the membership from the vlan Server. VLAN mode can be set for the whole unit or for individual ports. When a unit is initialised to factory defaults, lsConPortVLANConfigMode for every port is set to useDefault(2), and the actual setting for the port is decided by the value of lsConUnitVLANConfigMode. The other values of this object allow the setting to be varied for individual ports." ::= {lsConfigPortEntry 13} lsConPortStpFastStart OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies whether a switch port will transition immediately to the forwarding state, if spanning tree is turned on. When this object is set to on(2), the normal intermediate startup states of listening and learning are skipped and the port is allowed to enter the forwarding spanning tree state. This is to allow switch ports that are directly connected to workstations, to be immediately available when the link is detected or the switch powers up. Note that this object must be set of off(1) for all switch ports that are connected to ethernet segments or other switches." ::= {lsConfigPortEntry 14} -- -------------------------------------------------------------------------- -- -- VLAN Table -- -- This table provides details on the VLANs which have been setup -- on a LinkSwitch unit. -- -------------------------------------------------------------------------- lsVLANtable OBJECT-TYPE SYNTAX SEQUENCE OF LsVLANentry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table provides configuration information about the Virtual LANs on a LinkSwitch unit. A VLAN is a collection of ports which may freely communicate with each other; they exist in the same broadcast domain. Any port in a VLAN has restricted access to ports in other VLANs; Packets can only be transferred between ports in different VLANs via a router." ::= {linkSwitchConfigGroup 2} lsVLANentry OBJECT-TYPE SYNTAX LsVLANentry ACCESS not-accessible STATUS mandatory DESCRIPTION "Configuration information about a particular VLAN on a LinkSwitch unit." INDEX {lsVLANindex} ::= {lsVLANtable 1} LsVLANentry ::= SEQUENCE { lsVLANindex INTEGER, lsVLANname DisplayString, lsVLANdlUnitId INTEGER, lsVLANdlPortId INTEGER, lsVLANrowStatus INTEGER, lsVLANdbAction INTEGER } lsVLANindex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This attribute uniquely identifies one of the VLANs on a unit, and is also used as an index into the VLAN table. The value is also identical to the value of ifIndex for the VLAN." ::= {lsVLANentry 1} lsVLANname OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies a text string which uniquely identifies the VLAN. It may be set only if the value of lsVLANrowStatus is notInService(2)." ::= {lsVLANentry 2} lsVLANdlUnitId OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "When a frame is received with an unknown destination address, some devices send it to all ports in the same VLAN as the originating port, while others send it to a single port which is nominated for the purpose, known as the downlink. Whether downlinks are supported by a particular unit can be determined by reading the value of lsConUnitFwdingAction. This object specifies the identity of the unit on which this VLAN's downlink resides. It may be set only if the value of lsVLANrowStatus is notInService(2). If this VLAN does not have a downlink, either because the unit does not support them or because one has not been configured, this object and lsVLANdlPortId are both zero. See the description of lsVLANrowStatus for an explanation of the interaction with the setting of lsConPortVLANmode for the downlink port." ::= {lsVLANentry 3} lsVLANdlPortId OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "When a frame is received with an unknown destination address, some devices send it to all ports in the same VLAN as the originating port, while others send it to a single port which is nominated for the purpose, known as the downlink. Whether downlinks are supported by a particular unit can be determined by reading the value of lsConUnitFwdingAction. This object identifies the downlink port for this VLAN. It may be set only if the value of lsVLANrowStatus is notInService(2). If this VLAN does not have a downlink, either because the unit does not support them or because one has not been configured, this object and lsVLANdlUnitId are both zero. See the description of lsVLANrowStatus for an explanation of the interaction with the setting of lsConPortVLANmode for the downlink port." ::= {lsVLANentry 4} lsVLANrowStatus OBJECT-TYPE SYNTAX INTEGER { active (1), notInService (2), notReady (3), createAndGo (4), createAndWait (5), destroy (6) } ACCESS read-write STATUS mandatory DESCRIPTION "The VLAN table contains a row for each of the 16 VLANs that exist on a unit. Ports can be assigned to any active VLAN. VLANs cannot be created or deleted, so sets of this object with values createAndGo(4), createAndWait(5) or destroy(6) will be rejected. A get of this object will only ever return the values active(1) or notInService(2). Only if the status of the row is notInService(2) will sets of the downlink unit or port be successful. Changes will not take effect until active(1) is next written to the rowStatus. Thus, to amend the downlink for a VLAN the network manager must first set rowStatus to notInService(2), set the new values for the downlink, then set rowStatus back to active(1). This will fail in the following circumstances:- (1) the unit does not support downlinks (the value of lsConUnitFwdingAction is not fwdToDlink(2)), or (2) the port does not exist, or (3) the port is not a Virtual LAN Trunk, and the port is not assigned to the VLAN (a Virtual LAN Trunk is defined by setting lsConPortVLANmode for a port to multiplex(3)), or (4) The existing downlink is a Virtual LAN Trunk. Before the downlink may be changed the attribute must be removed from the port by setting lsConPortVLANmode to normal(2). If the new downlink port is a Virtual LAN Trunk (lsConPortVLANmode is set to multiplex(3)) the LinkSwitch agent will force the port to be the downlink port for all other VLANs as well. If the port is later changed back to normal(2), it will remain the downlink for the default VLAN (1001), and all the other VLANs will be reconfigured to have no downlink." ::= {lsVLANentry 5} lsVLANdbAction OBJECT-TYPE SYNTAX INTEGER { noAction (1), freezeAddrs (2) } ACCESS read-write STATUS deprecated DESCRIPTION "This object allows a user to carry out operations on this VLAN's address list in the forwarding database. freezeAddrs(2) makes all addresses in the VLAN permanent. The value noAction(1) is always returned in response to a get." ::= {lsVLANentry 6} -- ----------------------------------------------------------------------------- -- Configuration Unit Table -- -- This table provides details on the configuration of a Perseus unit. -- ----------------------------------------------------------------------------- lsConfigUnitTable OBJECT-TYPE SYNTAX SEQUENCE OF LsConfigUnitEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table providing configuration information about a Perseus unit." ::= {linkSwitchConfigGroup 3} lsConfigUnitEntry OBJECT-TYPE SYNTAX LsConfigUnitEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Configuration options for a Perseus unit." INDEX {lsConUnitId} ::= {lsConfigUnitTable 1} LsConfigUnitEntry ::= SEQUENCE { lsConUnitId INTEGER, lsConUnitFwdingAction INTEGER, lsConUnitFwdingMode INTEGER, lsConUnitPaceMode INTEGER, lsConUnitHPType INTEGER, lsConUnitHPMaskValue OCTET STRING (SIZE(3)), lsConUnitStpSelect INTEGER, lsConUnitDuplexMode INTEGER, lsConUnitVLANConfigMode INTEGER, lsConUnitIntelligentFwdingStatus INTEGER } lsConUnitId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This attribute uniquely identifies a unit on a stack (or a card within a chassis) for which this table entry contains configuration information." ::= {lsConfigUnitEntry 1} lsConUnitFwdingAction OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), fwdToDlink (2), fwdToAll (3) } ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies what action a Perseus unit takes when it receives a packet with an unknown destination address. A unit can forward the packet to the downlink (if any) associated with the source port, or it can forward the packet to all its ports. When a Switch 1000 is set to fwdToAll(3), all existing backbone port selection logic and stored configuration is erased. Any attempt to define a downlink via the lsVLANtable will be rejected when this object is set to fwdToAll. The Switch 3000 and Desktop switch will reject any attempt to write to this object." ::= {lsConfigUnitEntry 2} lsConUnitFwdingMode OBJECT-TYPE SYNTAX INTEGER { fastForward(1), fragmentFree(2), storeAndForward(3), intelligent(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This object controls whether cut-thru is enabled on the unit. Enabling cut-thru can help to minimise the delay experienced by packets before they are forwarded to their destination. Setting cut-thru to 'fastForward' causes frame forwarding to begin as soon as 32 bytes of the frame have been received. Setting it to 'fragmentFree' causes frame forwarding to begin when 64 bytes have been received. This is slower, but eliminates the risk of forwarding an illegally short frame to the destination port, however a valid length frame might still be forwarded even though it had a CRC error. Setting this object to 'storeAndForward' disables cut-thru completely, and frames will not be forwarded until they have been received in their entirety. When the mode is set to intelligent, the effective switching mode is set initially to fast forward. The switch then monitors the total error rate of frames received by the unit, and if it exceeds 18 error frames a second it changes the effective mode to store and forward. If the error rate then drops to zero the effective mode is restored to fast forward. The current forwarding mode that is active, when this object is set to intelligent(4) is indicated by the object lsConUnitIntelligentFwdingMode. Whatever forwarding mode is selected, cut-thru cannot operate if the destination port is currently involved in 'cut-thru' from another port. In this case the device will process the frame in store and forward mode." ::= {lsConfigUnitEntry 3} lsConUnitPaceMode OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), normalEthernet(2), lowLatency(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the type of backoff algorithm used on a LinkSwitch unit. Any port can use the standard ethernet algorithm or, for PACE applications, it can be set into low latency mode. In this mode, the backoff algorithm is optimised to minimise the possibility of collisions. The value of this object defines the setting that those ports will use which have lsConPortPaceMode set to useDefault(2). PACE mode can be set for the whole unit or for individual ports. When a unit is initialised to factory defaults, lsconPortPaceMode for every port is set to useDefault(2), and the actual setting for the port is decided by the value of lsConUnitPaceMode. The unit setting can thus be varied on a port by port basis." ::= {lsConfigUnitEntry 4} lsConUnitHPType OBJECT-TYPE SYNTAX INTEGER { noHighPriority(1), localBit(2), useMask(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies how the unit should decide if a packet is high priority, or normal priority. The priority is determined from the source address of an incoming packet. If this object is set to localBit, then any packets with the local bit set will be considered to be high priority. If this object is set to useMask, then the OUI of the source address will be compared with value of lsUnitHPMaskValue, if they are the same the packet is considered high priority." ::= {lsConfigUnitEntry 5} lsConUnitHPMaskValue OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) ACCESS read-write STATUS mandatory DESCRIPTION "This object sets the mask which will be used to determine if a packet is high or normal priority, if the OUI of the source address matches this mask, then the packet will be considered to be high priority." ::= {lsConfigUnitEntry 6} lsConUnitStpSelect OBJECT-TYPE SYNTAX INTEGER (1..15) ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies which Spanning Tree agent will be visible via the standard bridge MIB agent interface seen at mib2(1)-dot1dBridge(17). If the module is using AutoSelect mode VLANs, then the spanning tree agent for VLAN15 will not be available to select through this attribute." ::= {lsConfigUnitEntry 7} lsConUnitDuplexMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), halfDuplex (2), fullDuplex (3), other (4), halfDuplex10Mbps (5), fullDuplex10Mbps (6), autoNegotiated (7) } ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the mode of the link between a port and its endstations for all ports in the unit which have the lsConPortMode object set to useDefault(4). If the attribute is set set to 'fullDuplex', these ports will send and receive frames simultaneously without generating collisions on the network. If the attribute is set to 'halfDuplex', the normal rules of ethernet apply. Ports not capable of auto-negotiation use only the first three values defined and operate at their native speed. Ports capable of auto-negotiation also use the last three values. For such ports, 'halfDuplex' and 'fullDuplex' imply 100Mbps operation. 'halfDuplex10Mbps' and 'fullDuplex10Mbps' set the duplex mode of the port as described above and also set the port to 10Mbps operation. 'autoNegotiated' puts the port into auto-negotiated mode, whereby the duplex mode and operating speed are dynamically determined by the capabilities of the endstation." ::= {lsConfigUnitEntry 8} lsConUnitVLANConfigMode OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), portMode(2), autoSelect(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the vlan mode used whereby portMode requires the user to configure the port's vlan membership and autoSelectMode acquires the membership from the vlan Server. The value of this object defines the setting that those ports which have lsConPortVLANConfigMode set to useDefault(2) will use. VLAN mode can be set for the whole unit or for individual ports. When a unit is initialised to factory defaults, lsConPortVLANConfigMode for every port is set to useDefault(2), and the actual setting for the port is decided by the value of lsConUnitVLANConfigMode. The unit setting can thus be varied on a port by port basis." ::= {lsConfigUnitEntry 9} lsConUnitIntelligentFwdingStatus OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), fastForward(2), storeAndForward(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the currently active mode that has been chosen by the intelligent forwarding engine. When the object lsConUnitFwdingMode indicates intelligent(4), this object will return the current forwarding mode selection, otherwise it will indicate notApplicable(1)." ::= {lsConfigUnitEntry 10} -- ----------------------------------------------------------------------------- -- Monitor Group -- ----------------------------------------------------------------------------- linkSwitchMonitorGroup OBJECT IDENTIFIER ::= {linkSwitch1000-mib 3} -- ----------------------------------------------------------------------------- -- Monitor VLAN Table -- -- This group provides monitoring information about a Perseus hub on a -- VLAN level. -- ----------------------------------------------------------------------------- lsMonitorWGTable OBJECT-TYPE SYNTAX SEQUENCE OF LsMonWgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table provides monitoring information on the Virtual LANs (VLANs) which exist in a LinkSwitch. VLANs were originally known as Workgroups, hence the naming of the object identifiers." ::= {linkSwitchMonitorGroup 1} lsMonitorWGTableEntry OBJECT-TYPE SYNTAX LsMonWgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Monitoring information for a single VLAN." INDEX {lsMonWgIndex} ::= {lsMonitorWGTable 1} LsMonWgEntry ::= SEQUENCE { lsMonWgIndex INTEGER, lsMonWgTxFrames Counter, lsMonWgTxOctets Counter, lsMonWgTxErrors Counter, lsMonWgRxCongestion Counter, lsMonWgTxCongestion Counter, lsMonWgFilteredFrms Counter, lsMonWgForwardedFrms Counter, lsMonWgTxUnderruns Counter, lsMonWgRxDribble Counter, lsMonWgCutThrus Counter, lsMonWgJamCount Counter, lsMonWgClearCounters INTEGER, lsMonWgRxMulticast Counter, lsMonWgTxMulticast Counter } lsMonWgIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A stack/chassis may contain more than one VLAN. This parameter uniquely identifies the VLAN which is the target of the request." ::= {lsMonitorWGTableEntry 1} lsMonWgTxFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This parameter specifies the number of frames (including error frames) which were transmitted by ports in this VLAN." ::= {lsMonitorWGTableEntry 2} lsMonWgTxOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This parameter specifies the number of octets (including octets in error frames) which were transmitted by ports in this VLAN." ::= {lsMonitorWGTableEntry 3} lsMonWgTxErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This parameter specifies the number of error frames which were transmitted by ports in this VLAN." ::= {lsMonitorWGTableEntry 4} lsMonWgRxCongestion OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This parameter specifies the number of frames which were dropped due to congestion (lack of buffer resource) on the receive side of ports in this VLAN." ::= {lsMonitorWGTableEntry 5} lsMonWgTxCongestion OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This parameter specifies the number of frames which were dropped due to congestion (lack of buffer resource) on the transmit side of ports in this VLAN." ::= {lsMonitorWGTableEntry 6} lsMonWgFilteredFrms OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of frames within a VLAN that were filtered because the destination station was on the same segment (port) as the source station." ::= {lsMonitorWGTableEntry 7} lsMonWgForwardedFrms OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of frames that were forwarded successfully by ports in this VLAN to their destinations." ::= {lsMonitorWGTableEntry 8} lsMonWgTxUnderruns OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of frames within this VLAN that were transmitted with a bad CRC because the MMAC did not have enough data to continue transmission." ::= {lsMonitorWGTableEntry 9} lsMonWgRxDribble OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of frames that were received by ports in this VLAN which had dribble bits at the end of the frames" ::= {lsMonitorWGTableEntry 10} lsMonWgCutThrus OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of frames that were forwarded to their destination in 'cut-thru' mode by ports in this VLAN. When a port is operating in 'cut-thru' mode, it starts forwarding the frame to its destination before the frame has been fully received." ::= {lsMonitorWGTableEntry 11} lsMonWgJamCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of attempts made to jam frames due to insufficient resources at the receive ports in this VLAN." ::= {lsMonitorWGTableEntry 12} lsMonWgClearCounters OBJECT-TYPE SYNTAX INTEGER { noChangeCounters (1), clearCounters (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute is used to clear all counters on all ports in a VLAN." ::= {lsMonitorWGTableEntry 13} lsMonWgRxMulticast OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This parameter specifies the number of multicast/broadcast frames which were received by ports in this VLAN." ::= {lsMonitorWGTableEntry 14} lsMonWgTxMulticast OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This parameter specifies the number of multicast/broadcast frames which were transmitted by ports in this VLAN." ::= {lsMonitorWGTableEntry 15} -- ----------------------------------------------------------------------------- -- Monitor Port Table -- -- This table provides monitoring information about a port on a Perseus -- unit. -- ----------------------------------------------------------------------------- lsMonitorPortTable OBJECT-TYPE SYNTAX SEQUENCE OF LsMonPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table provides monitoring information about a port on a Perseus unit. This information is in addition to the statistical information already provided by the 'mrmMonPort' table. Note: The 'mrmMonPort' table has objects which provide the value of RxFrames, RxOctets and RxErrors on a port." ::= {linkSwitchMonitorGroup 2} lsMonitorPortTableEntry OBJECT-TYPE SYNTAX LsMonPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Monitor options for a single port." INDEX {lsMonPortWgIndex,lsMonPortUnitId,lsMonPortId} ::= {lsMonitorPortTable 1} LsMonPortEntry ::= SEQUENCE { lsMonPortWgIndex INTEGER, lsMonPortUnitId INTEGER, lsMonPortId INTEGER, lsMonPortReceivedFrms Counter, lsMonPortTransmittedFrms Counter, lsMonPortFilteredFrms Counter, lsMonPortForwardedFrms Counter, lsMonPortFragmentFrms Counter, lsMonPortRxCongestion Counter, lsMonPortTxCongestion Counter, lsMonPortTxUnderruns Counter, lsMonPortRxDribble Counter, lsMonPortCutThrus Counter, lsMonPortRxJamCount Counter, lsMonPortPercentFwd INTEGER, lsMonPortBcastBndwth INTEGER, lsMonPortClearCounters INTEGER, lsMonPortTxMulticast Counter, lsMonPortRxBndwdth INTEGER, lsMonPortTxBndwdth INTEGER, lsMonPortRxMulticast Counter, lsMonPortRxBroadcast Counter } lsMonPortWgIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A stack/chassis may contain more than one Virtual LAN (VLAN). This parameter uniquely identifies the VLAN which is the target of the request." ::= {lsMonitorPortTableEntry 1} lsMonPortUnitId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A stack/chassis may contain more than one unit/card. This parameter uniquely identifies the unit/card which is the target of a request." ::= {lsMonitorPortTableEntry 2} lsMonPortId OBJECT-TYPE SYNTAX INTEGER (1..32) ACCESS read-only STATUS mandatory DESCRIPTION "A unit/card contains many ports. This parameter uniquely identifies the port which is the target of a request." ::= {lsMonitorPortTableEntry 3} lsMonPortReceivedFrms OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of good and bad frames that were received at this port." ::= {lsMonitorPortTableEntry 4} lsMonPortTransmittedFrms OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of good and bad frames that were transmitted from this port." ::= {lsMonitorPortTableEntry 5} lsMonPortFilteredFrms OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of frames that were filtered because the destination station was on the same segment (port) as the source station." ::= {lsMonitorPortTableEntry 6} lsMonPortForwardedFrms OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of frames which were received by this port and forwarded to their destinations." ::= {lsMonitorPortTableEntry 7} lsMonPortFragmentFrms OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of frames less than 64 octets and with a bad CRC that were received at/transmitted from this port." ::= {lsMonitorPortTableEntry 8} lsMonPortRxCongestion OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This parameter specifies the number of frames which were dropped due to congestion (lack of buffer resource) on the receive side of this port." ::= {lsMonitorPortTableEntry 9} lsMonPortTxCongestion OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This parameter specifies the number of frames which were dropped due to congestion (lack of buffer resource) on the transmit side of this port." ::= {lsMonitorPortTableEntry 10} lsMonPortTxUnderruns OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of frames that were transmitted with a bad CRC because the MMAC did not have enough data to continue transmission." ::= {lsMonitorPortTableEntry 11} lsMonPortRxDribble OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames that were received on this port with dribble bits at the end of the frame." ::= {lsMonitorPortTableEntry 12} lsMonPortCutThrus OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of frames that were forwarded to their destination in 'cut-through' mode. When a port is operating in 'cut-through' mode, it starts forwarding the frame to its destination before the frame has been fully received." ::= {lsMonitorPortTableEntry 13} lsMonPortRxJamCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of attempts made to jam packets due to insufficient resources at the receive port." ::= {lsMonitorPortTableEntry 14} lsMonPortPercentFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This is a high level 'Smart' MIB object. This object provides a running sample of the proportion of the received frames that are forwarded. This value is calculated locally on the agent and so does not require processor bandwidth from the management station or occupy valuable network bandwidth communicating with that station. By default an agent supporting this parameter will exhibit the following characteristics :- (1) The parameter will be recalculated at approx 60 second intervals. (2) Every calculation period, the device will read the value of lsMonPortReceivedFrms and lsmonPortForwardedFrms. (3) The change in these two statistics since the last sample period will be calculated. (4) The percentage of frames forwarded is then computed as (forwarded * 100) / received (where these are the frames forwarded and received in the last 60 seconds). The value is expressed as a percentage. A default threshold exists on this value so that if it exceeds 85%, a trap will be sent to the management station. Further traps will not be sent until it drops to below 50%. A particular device may provide the means of changing the the sample period, threshold and threshold action if it so wishes." ::= {lsMonitorPortTableEntry 15} lsMonPortBcastBndwth OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This is a high level 'Smart' MIB object. This object provides a running average of the Broadcast frame bandwidth in use. This value is calculated locally on the agent and so does not require processor bandwidth from the management station or occupy valuable network bandwidth communicating with that station. By default an agent supporting this parameter will exhibit the following characteristics: (1) The parameter will be recalculated at approx 20 second intervals (2) Every calculation period the device will read the value of lsMonPortRxBroadcast (3) The change in this statistic during the last sample period will be calculated (4) the number of octets in these broadcast frames will be estimated using an average broadcast frame size of 128 octets (5) The bandwidth used will be computed as (octets * 100) / (sample-time * MAX) where MAX is the maximum number of octets that the network can transfer in one second, and depends on the speed of the port. The value is expressed as a percentage. A default threshold exists on this average so that if a calculated average exceeds 20% a trap will be sent to the management station. Further traps will not be sent until the average drops to below 10%. A particular device may provide a means of changing the number of samples, the averaging period, threshold and threshold action if it so wishes." ::= {lsMonitorPortTableEntry 16} lsMonPortClearCounters OBJECT-TYPE SYNTAX INTEGER { noChangeCounters (1), clearCounters (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute is used to clear all counters on a port." ::= {lsMonitorPortTableEntry 17} lsMonPortTxMulticast OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of multicast/broadcast frames received on this port." ::= {lsMonitorPortTableEntry 18} lsMonPortRxBndwdth OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This attribute is used to return the running average of the Rx bandwidth in use. See 'mrmMonPortBandwidthUsed' for a description of how the bandwidth used is calculated." ::= {lsMonitorPortTableEntry 19} lsMonPortTxBndwdth OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This attribute is used to return the running average of the Tx bandwidth in use. See 'mrmMonPortBandwidthUsed' for a description of how the bandwidth used is calculated." ::= {lsMonitorPortTableEntry 20} lsMonPortRxMulticast OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of multicast frames received on this port." ::= {lsMonitorPortTableEntry 21} lsMonPortRxBroadcast OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of broadcast frames received on this port." ::= {lsMonitorPortTableEntry 22} -- ----------------------------------------------------------------------------- -- Database Group -- ----------------------------------------------------------------------------- linkSwitchDatabaseGroup OBJECT IDENTIFIER ::= {linkSwitch1000-mib 4} lsDatabaseSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This parameter indicates the number of permanent and non-permanent entries currently held in the database on a linkSwitch1000 hub." ::= {linkSwitchDatabaseGroup 1} lsPermDatabaseSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This parameter indicates the number of permanent addresses currently held in the database on a linkSwitch1000." ::= {linkSwitchDatabaseGroup 2} -- ----------------------------------------------------------------------------- -- Port Table -- -- This group provides a view of the database on a linkSwitch1000 unit in -- ascending port number order. -- ----------------------------------------------------------------------------- lsDbPortTable OBJECT-TYPE SYNTAX SEQUENCE OF LsDbPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Port View Table" ::= {linkSwitchDatabaseGroup 3} lsDbPortEntry OBJECT-TYPE SYNTAX LsDbPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Port View Table entry" INDEX {lsDbPortUnitId, lsDbPortPortId, lsDbPortIndex} ::= {lsDbPortTable 1} LsDbPortEntry ::= SEQUENCE { lsDbPortUnitId INTEGER, lsDbPortPortId INTEGER, lsDbPortIndex INTEGER, lsDbPortAddress OCTET STRING, lsDbPortAddrStatus INTEGER, lsDbPortAddrPriority INTEGER } lsDbPortUnitId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A LinkSwitch stack may contain up to 4 units. This parameter uniquely identifies the unit on which the address was learnt." ::= {lsDbPortEntry 1} lsDbPortPortId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A linkSwitch1000 unit can contain up to 26 ports. This parameter uniquely the port on which the address was learnt." ::= {lsDbPortEntry 2} lsDbPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Multiple addresses can be learnt on a single port. This parameter uniquely identifies one address on a port." ::= {lsDbPortEntry 3} lsDbPortAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(6)) ACCESS read-write STATUS mandatory DESCRIPTION "The physical address of the station which has been learnt on a port on a linkSwitch1000 stack." ::= {lsDbPortEntry 4} lsDbPortAddrStatus OBJECT-TYPE SYNTAX INTEGER { nonPermanent (1), permanent (2), delete (3) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute indicates if the address will age out of the database on a linkSwitch1000 unit when it is not the subject of lookup requests (nonPermanent) OR if it remains in the database until the user deletes it (permanent). The user can remove this address from the database by setting this attribute to delete(3)." ::= {lsDbPortEntry 5} lsDbPortAddrPriority OBJECT-TYPE SYNTAX INTEGER { normalPriority (1), highPriority (2) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates if the address has been designated a high priority address, in which case packets from that address will get priority through the switch, or if it is normal priority." ::= {lsDbPortEntry 6} -- ----------------------------------------------------------------------------- -- Smart MIB Object Group -- ----------------------------------------------------------------------------- linkSwitchSmartGroup OBJECT IDENTIFIER ::= {linkSwitch1000-mib 5} lsSmartPercentFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This is a smart MIB object which is used internally by the agent to provide a running average of the percentage of incoming frames which are forwarded. It should not be accessed by a management station and is used by the logic which calculates the value of its associated object 'mrmMonPortPercentFwd'." ::= {linkSwitchSmartGroup 1} lsSmartBcastBndwdth OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This is a smart MIB object which is used internally by the agent to provide a running average of the broadcast bandwidth in use. It should not be accessed by a management station and is used by the logic which calculates its associated object 'lsMonPortBcastBndwdth'." ::= {linkSwitchSmartGroup 2} lsSmartRxBndwdth OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This is a smart MIB object which is used internally by the agent to provide a running average of the Rx frame bandwidth. It should not be accessed by a management station and is used by the logic which calculates its associated object 'lsMonPortRxBndwdth'." ::= {linkSwitchSmartGroup 3} lsSmartTxBndwdth OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This is a smart MIB object which is used internally by the agent to provide a running average of the Tx frame bandwidth. It should not be accessed by a management station and is used by the logic which calculates its associated object 'lsMonPortTxBndwdth'." ::= {linkSwitchSmartGroup 4} END