-- -- Converted to SMIv2 rfc 2578,2579,2580 - STD 58 -- ATM-FORUM-MIB DEFINITIONS ::= BEGIN -- ATM-FORUM-TC-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises, Counter32, IpAddress, Integer32, OBJECT-TYPE, MODULE-IDENTITY FROM SNMPv2-SMI DisplayString FROM SNMPv2-TC; -- atmForum, -- TruthValue, -- ClnpAddress, -- AtmServiceCategory, -- atmfPhysicalGroup, -- atmfAtmLayerGroup, -- atmfAtmStatsGroup, -- atmfVpcGroup, -- atmfVccGroup, -- atmfVpcAbrGroup, -- atmfVccAbrGroup FROM ATM-FORUM-TC-MIB -- TRAP-TYPE FROM RFC-1215 -- -- a subtree for defining ATM Forum MIB object types atmForum MODULE-IDENTITY LAST-UPDATED "9911060000z" ORGANIZATION "The ATM Forum" CONTACT-INFO "The ATM Forum 2570 West El Camino Real, Suite 304 Mountain View, CA 94040-1313 USA Phone: +1 415-949-6700 Fax: +1 415-949-6705 info@atmforum.com" DESCRIPTION "The MIB module for defining ATM Forum MIB object types." ::= { enterprises 353 } -- -- Textual Conventions -- Boolean values use this data type from RFC-1903, "Textual Conventions -- for Version 2 of the Simple Network Management Protocol (SNMPv2)" TruthValue ::= INTEGER { true(1), false(2) } -- CLNP address values use this data type from RFC-1238, "CLNS MIB for -- use with Connectionless Network Protocol (ISO 8473) and End System -- to Intermediate System (ISO 9542)" -- ClnpAddress ::= OCTET STRING (SIZE (1..21)) -- -- ATM Service Categories use this data type (See [TM4.0]): AtmServiceCategory ::= INTEGER { other(1), cbr(2), rtVbr(3), nrtVbr(4), abr(5), ubr(6) } -- ATM End-System Addresses use this data type: AtmAddress ::= OCTET STRING (SIZE (8 | 20)) -- Network-Prefixes for an ATM Address use this data type: -- NetPrefix ::= OCTET STRING (SIZE (8 | 13)) -- -- In both the AtmAddress and NetPrefix conventions, Native E.164 addresses -- are represented as 8 octets using the format specified in section -- 3.1.1.3 of the ATM Forum UNI Signalling 4.0 specification. -- In contrast, an NSAP-encoded address is 20 octets, and an NSAP-encoded -- network prefix is 13 octets long. -- a subtree for defining administrative object types atmForumAdmin OBJECT IDENTIFIER ::= { atmForum 1 } atmfTransmissionTypes OBJECT IDENTIFIER ::= { atmForumAdmin 2 } atmfMediaTypes OBJECT IDENTIFIER ::= { atmForumAdmin 3 } atmfTrafficDescrTypes OBJECT IDENTIFIER ::= { atmForumAdmin 4 } atmfSrvcRegTypes OBJECT IDENTIFIER ::= { atmForumAdmin 5 } -- a subtree for defining ATM Interface MIB object types atmForumUni OBJECT IDENTIFIER ::= { atmForum 2 } atmfPhysicalGroup OBJECT IDENTIFIER ::= { atmForumUni 1 } atmfAtmLayerGroup OBJECT IDENTIFIER ::= { atmForumUni 2 } atmfAtmStatsGroup OBJECT IDENTIFIER ::= { atmForumUni 3 } atmfVpcGroup OBJECT IDENTIFIER ::= { atmForumUni 4 } atmfVccGroup OBJECT IDENTIFIER ::= { atmForumUni 5 } atmfAddressGroup OBJECT IDENTIFIER ::= { atmForumUni 6 } -- atmfNetPrefixGroup OBJECT IDENTIFIER ::= { atmForumUni 7 } atmfSrvcRegistryGroup OBJECT IDENTIFIER ::= { atmForumUni 8 } atmfVpcAbrGroup OBJECT IDENTIFIER ::= { atmForumUni 9 } atmfVccAbrGroup OBJECT IDENTIFIER ::= { atmForumUni 10 } atmfAddressRegistrationAdminGroup OBJECT IDENTIFIER ::= { atmForumUni 11 } -- Object Identifier definitions -- Transmission Types: These values are no longer used atmfUnknownType OBJECT IDENTIFIER ::= { atmfTransmissionTypes 1} atmfSonetSTS3c OBJECT IDENTIFIER ::= { atmfTransmissionTypes 2 } atmfDs3 OBJECT IDENTIFIER ::= { atmfTransmissionTypes 3 } atmf4B5B OBJECT IDENTIFIER ::= { atmfTransmissionTypes 4 } atmf8B10B OBJECT IDENTIFIER ::= { atmfTransmissionTypes 5 } atmfSonetSTS12c OBJECT IDENTIFIER ::= { atmfTransmissionTypes 6 } atmfE3 OBJECT IDENTIFIER ::= { atmfTransmissionTypes 7 } atmfT1 OBJECT IDENTIFIER ::= { atmfTransmissionTypes 8 } atmfE1 OBJECT IDENTIFIER ::= { atmfTransmissionTypes 9 } -- Media Types: These values are no longer used atmfMediaUnknownType OBJECT IDENTIFIER ::= { atmfMediaTypes 1 } atmfMediaCoaxCable OBJECT IDENTIFIER ::= { atmfMediaTypes 2 } atmfMediaSingleMode OBJECT IDENTIFIER ::= { atmfMediaTypes 3 } atmfMediaMultiMode OBJECT IDENTIFIER ::= { atmfMediaTypes 4 } atmfMediaStp OBJECT IDENTIFIER ::= { atmfMediaTypes 5 } atmfMediaUtp OBJECT IDENTIFIER ::= { atmfMediaTypes 6 } -- Traffic Descriptor Types: These types are combined with a five element -- parameter vector to describe a Traffic Descriptor. -- Traffic Descriptors along with a Best Effort Indicator are used to -- indicate a Conformance Definition as defined in [TM4.0]. -- These types are no longer used atmfNoDescriptor OBJECT IDENTIFIER ::= { atmfTrafficDescrTypes 1 } atmfPeakRate OBJECT IDENTIFIER ::= { atmfTrafficDescrTypes 2 } -- The No CLP/No SCR Type -- Indicates the CBR.1 Conformance Definition if Best Effort is No -- Indicates the UBR.1 and UBR.2 Conformance Definitions if Best Effort is Yes atmfNoClpNoScr OBJECT IDENTIFIER ::= { atmfTrafficDescrTypes 3 } -- The use of the parameter vector for this type: -- Parameter #1 - peak cell rate in cells/second for CLP=0+1 traffic -- Parameter #2 - CDVT in tenths of microseconds -- Parameters #3, #4 and #5 are unused -- These types are no longer used atmfClpNoTaggingNoScr OBJECT IDENTIFIER ::= { atmfTrafficDescrTypes 4 } atmfClpTaggingNoScr OBJECT IDENTIFIER ::= { atmfTrafficDescrTypes 5 } -- The SCR/No CLP Type -- Indicates the VBR.1 Conformance Definition atmfNoClpScr OBJECT IDENTIFIER ::= { atmfTrafficDescrTypes 6 } -- The use of the parameter vector for this type: -- Parameter #1 - peak cell rate in cells/second for CLP=0+1 traffic -- Parameter #2 - sustainable cell rate in cells/second for CLP=0+1 traffic -- Parameter #3 - maximum burst size in cells -- Parameter #4 - CDVT in tenths of microseconds -- Parameter #5 - unused -- The CLP without Tagging/SCR Type -- Indicates the VBR.2 Conformance Definition atmfClpNoTaggingScr OBJECT IDENTIFIER ::= { atmfTrafficDescrTypes 7 } -- The use of the parameter vector for this type: -- Parameter #1 - peak cell rate in cells/second for CLP=0+1 traffic -- Parameter #2 - sustainable cell rate in cells/second for CLP=0 traffic -- Parameter #3 - maximum burst size in cells -- Parameter #4 - CDVT in tenths of microseconds -- Parameter #5 - unused -- The CLP with Tagging/SCR Type -- Indicates the VBR.3 Conformance Definition atmfClpTaggingScr OBJECT IDENTIFIER ::= { atmfTrafficDescrTypes 8 } -- The use of the parameter vector for this type: -- Parameter #1 - peak cell rate in cells/second for CLP=0+1 traffic -- Parameter #2 - sustainable cell rate in cells/second for CLP=0 -- traffic, excess tagged as CLP=1 -- Parameter #3 - maximum burst size in cells -- Parameter #4 - CDVT in tenths of microseconds -- Parameter #5 - unused -- The ABR Type -- Indicates the ABR Conformance Definition atmfClpNoTaggingMcr OBJECT IDENTIFIER ::= { atmfTrafficDescrTypes 9 } -- The use of the parameter vector for this type: -- Parameter #1 - peak cell rate in cells/second -- parameter #2 - CDVT in tenths of microseconds -- Parameter #3 - minimum cell rate in cells/second -- Parameter #4 - unused -- Parameter #5 - unused -- END -- Textual Conventions -- All representations of ATM addresses in this MIB Module use -- the data type: -- AtmAddress ::= OCTET STRING (SIZE (0 .. 32)) -- Note this data type is used only by the deprecated object -- atmfPortAddress. Another definition (a refined one) is -- specified in the Textual Conventions MIB. -- The Physical Port Group -- -- This group is mandatory for all ATM Interface devices. -- -- The Physical Port Table atmfPortTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmfPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of physical layer status and parameter information for the ATM Interface's physical interface." ::= { atmfPhysicalGroup 1 } atmfPortEntry OBJECT-TYPE SYNTAX AtmfPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table, containing information about the physical layer of an ATM Interface." INDEX { atmfPortIndex } ::= { atmfPortTable 1 } AtmfPortEntry ::= SEQUENCE { atmfPortIndex Integer32, -- atmfPortAddress -- AtmAddress, atmfPortTransmissionType OBJECT IDENTIFIER, atmfPortMediaType OBJECT IDENTIFIER, atmfPortOperStatus INTEGER, atmfPortSpecific OBJECT IDENTIFIER, atmfPortMyIfName DisplayString, atmfPortMyIfIdentifier Integer32 } atmfPortIndex OBJECT-TYPE SYNTAX Integer32(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of 0 which has the special meaning of identifying the ATM Interface over which this message was received." ::= { atmfPortEntry 1 } -- atmfPortAddress OBJECT-TYPE -- SYNTAX AtmAddress -- ACCESS read-only -- STATUS obsolete -- DESCRIPTION -- "This object should not be implemented except as -- required for backward compatibility with version 2.0 -- of the UNI specification. The Address Group, defined -- in theAddress Registration MIB should be used instead." -- ::= { atmfPortEntry 2 } atmfPortTransmissionType OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This object should not be implemented except as required for backward compatibility with version 3.1 of the UNI specification. Appropriate Network Management MIBs should be used instead." ::= { atmfPortEntry 3 } atmfPortMediaType OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This object should not be implemented except as required for backward compatibility with version 3.1 of the UNI specification. Appropriate Network Management MIBs should be used instead." ::= { atmfPortEntry 4 } atmfPortOperStatus OBJECT-TYPE SYNTAX INTEGER { other(1), inService(2), outOfService(3), loopBack(4) } MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This object should not be implemented except as required for backward compatibility with version 3.1 of the UNI specification. Appropriate Network Management MIBs should be used instead." ::= { atmfPortEntry 5 } atmfPortSpecific OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This object should not be implemented except as required for backward compatibility with version 3.1 of the UNI specification. Appropriate Network Management MIBs should be used instead." ::= { atmfPortEntry 6 } atmfPortMyIfName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A textual name of this interface. If this system is manageable through SNMP, and supports the object ifName, the value of this object must be identical with that of ifName for the ifEntry of the lowest level physical interface for this port. This interface must be uniquely named on this system to distinguish parallel links with a neighboring system. If this interface does not have a textual name, the value of this object is a zero length string." ::= { atmfPortEntry 7 } atmfPortMyIfIdentifier OBJECT-TYPE SYNTAX Integer32(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value for each ATM interface. The scheme used to number the ATM interfaces on an ATM device is implementation specific. One way to generate this value is to use the ifIndex that an SNMP manager would use to identify the port. This interface must be uniquely numbered on this system to distinguish parallel links with a neighboring system." ::= { atmfPortEntry 8 } -- Note: The typical IME will support only one of the following two objects atmfMyIpNmAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "An IP Address to which a Network Management Station can send Network Management protocol messages, e.g. SNMP messages to UDP port 161, in order to access network management information concerning the operation of the ATM device local to this IME. If this object is supported, but the Network Management Agent has not been configured with an IP Address, the IME should return 0.0.0.0." ::= { atmfPhysicalGroup 2 } -- atmfMyOsiNmNsapAddress OBJECT-TYPE -- SYNTAX ClnpAddress -- ACCESS read-only -- STATUS mandatory -- DESCRIPTION -- "An NSAP Address to which a Network Management Station -- can send Network Management protocol messages in order -- to access network management information concerning -- the operation of the ATM device local to this IME. -- If this object is supported, -- but the Network Management Agent has not been configured with -- an NSAP Address, the IME should return 0.0.0.0" -- ::= { atmfPhysicalGroup 3 } atmfMySystemIdentifier OBJECT-TYPE SYNTAX OCTET STRING (SIZE (6)) MAX-ACCESS read-only STATUS current DESCRIPTION "A 48 bit identifier, taken from the IEEE universally administered MAC address space, which uniquely identifies the ATM device local to this IME." ::= { atmfPhysicalGroup 4 } -- The ATM Layer Group -- This group is mandatory for all ATM Interfaces. -- -- ATM-layer specific information for the ATM Interface. atmfAtmLayerTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmfAtmLayerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of ATM layer status and parameter information for the ATM Interface." ::= { atmfAtmLayerGroup 1 } atmfAtmLayerEntry OBJECT-TYPE SYNTAX AtmfAtmLayerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table, containing information about the ATM layer of an ATM Interface." INDEX { atmfAtmLayerIndex } ::= { atmfAtmLayerTable 1 } AtmfAtmLayerEntry ::= SEQUENCE { atmfAtmLayerIndex Integer32, atmfAtmLayerMaxVPCs Integer32, atmfAtmLayerMaxVCCs Integer32, atmfAtmLayerConfiguredVPCs Integer32, atmfAtmLayerConfiguredVCCs Integer32, atmfAtmLayerMaxVpiBits Integer32, atmfAtmLayerMaxVciBits Integer32, atmfAtmLayerUniType INTEGER, atmfAtmLayerUniVersion INTEGER, atmfAtmLayerDeviceType INTEGER, atmfAtmLayerIlmiVersion INTEGER, atmfAtmLayerNniSigVersion INTEGER, atmfAtmLayerMaxSvpcVpi Integer32, atmfAtmLayerMaxSvccVpi Integer32, atmfAtmLayerMinSvccVci Integer32 } atmfAtmLayerIndex OBJECT-TYPE SYNTAX Integer32(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of 0 which has the special meaning of identifying the ATM Interface over which this message was received." ::= { atmfAtmLayerEntry 1 } atmfAtmLayerMaxVPCs OBJECT-TYPE SYNTAX Integer32(0..4096) MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of switched and permanent VPCs supported on this ATM Interface. For virtual interfaces (i.e. Virtual Path Connections), the maximum number of VPCs PNNI may communicate over is set to zero." ::= { atmfAtmLayerEntry 2 } atmfAtmLayerMaxVCCs OBJECT-TYPE SYNTAX Integer32(0..268435456) MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of switched and permanent VCCs supported on this ATM Interface." ::= { atmfAtmLayerEntry 3 } atmfAtmLayerConfiguredVPCs OBJECT-TYPE SYNTAX Integer32(0..4096) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of permanent VPCs configured for use on this ATM Interface. For virtual interfaces (i.e. Virtual Path Connections used by PNNI), the maximum number of VPCs is set to zero." ::= { atmfAtmLayerEntry 4 } atmfAtmLayerConfiguredVCCs OBJECT-TYPE SYNTAX Integer32(0.. 268435456) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of permanent VCCs configured for use on this ATM Interface." ::= { atmfAtmLayerEntry 5 } atmfAtmLayerMaxVpiBits OBJECT-TYPE SYNTAX Integer32(0..12) MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of active VPI bits on this ATM Interface. For virtual interfaces (i.e. Virtual Path Connections used by PNNI), this value has no meaning and is set to zero." ::= { atmfAtmLayerEntry 6 } atmfAtmLayerMaxVciBits OBJECT-TYPE SYNTAX Integer32(0..16) MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of active VCI bits on this ATM Interface." ::= { atmfAtmLayerEntry 7 } atmfAtmLayerUniType OBJECT-TYPE SYNTAX INTEGER { public(1), private(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of the ATM device, either public or private." ::= { atmfAtmLayerEntry 8 } atmfAtmLayerUniVersion OBJECT-TYPE SYNTAX INTEGER { version2point0(1), version3point0(2), version3point1(3), version4point0(4), unsupported(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "An indication of the latest version of the ATM Forum UNI Signalling Specification that is supported on this ATM Interface. If this value is not present, a version of the UNI earlier than 3.1 is supported. If the peer IME's value of this object is the same as, or later than the local IME's value, then the version corresponding to the local IME's value should be attempted. Otherwise, if the peer IME's value of this object is earlier, and supported locally, then the local IME should attempt the version corresponding to the peer IME's value. Otherwise, compatibility of the two IMEs cannot be assumed." ::= { atmfAtmLayerEntry 9 } atmfAtmLayerDeviceType OBJECT-TYPE SYNTAX INTEGER { user(1), node(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object determines the type of the ATM device. This object is used in automatic ATM Interface-Type determination procedure such that a correct operational ATM Interface-type can be determined. An ATM End System shall take the value of user(1), and an ATM network node shall take the value of node(2)." ::= { atmfAtmLayerEntry 10 } atmfAtmLayerIlmiVersion OBJECT-TYPE SYNTAX INTEGER { unsupported(1), version4point0(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "An indication of the latest version of the ATM Forum ILMI Specification that is supported on this ATM Interface. If the peer IME's value of this object is the same as, or later than the local IME's value, then the version corresponding to the local IME's value should be attempted. Otherwise, if the peer IME's value of this object is earlier, and supported locally, then the local IME should attempt the version corresponding to the peer IME's value. Otherwise, compatibility of the two IMEs cannot be assumed. If this object is not present, a version of the ILMI earlier than 4.0 is supported." ::= { atmfAtmLayerEntry 11 } atmfAtmLayerNniSigVersion OBJECT-TYPE SYNTAX INTEGER { unsupported(1), iisp(2), pnniVersion1point0(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "An indication of the latest version of the ATM Forum PNNI Signalling Specification that is supported on this ATM Interface. Note that the PNNI routing version is not determined through ILMI. If the peer IME's value of this object is the same as, or later than the local IME's value, then the version corresponding to the local IME's value should be attempted. Otherwise, if the peer IME's value of this object is earlier, and supported locally, then the local IME should attempt the version corresponding to the peer IME's value. Otherwise, compatibility of the two IMEs cannot be assumed." ::= { atmfAtmLayerEntry 12 } atmfAtmLayerMaxSvpcVpi OBJECT-TYPE SYNTAX Integer32(0..4096) MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum VPI that the signalling stack on the ATM interface is configured to support for allocation to switched virtual path connections." ::= { atmfAtmLayerEntry 13 } atmfAtmLayerMaxSvccVpi OBJECT-TYPE SYNTAX Integer32(0..4096) MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum VPI that the signalling stack on the ATM interface is configured to support for allocation to switched virtual channel connections." ::= { atmfAtmLayerEntry 14 } atmfAtmLayerMinSvccVci OBJECT-TYPE SYNTAX Integer32(0..65536) MAX-ACCESS read-only STATUS current DESCRIPTION "This is the minimum VCI value that the signalling stack is configured to support for allocation to switched virtual channel connections. The same value applies to all SVCC VPI values for which the signalling stack is configured." ::= { atmfAtmLayerEntry 15 } -- The ATM Statistics Group -- This group is deprecated and should not be implemented except as -- required for backward compatibility with version 3.1 of the UNI -- specification. atmfAtmStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmfAtmStatsEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "This group is deprecated and should not be implemented except as required for backward compatibility with version 3.1 of the UNI specification." ::= { atmfAtmStatsGroup 1 } atmfAtmStatsEntry OBJECT-TYPE SYNTAX AtmfAtmStatsEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "This object should not be implemented except as required for backward compatibility with version 3.1 of the UNI specification." INDEX { atmfAtmStatsIndex } ::= { atmfAtmStatsTable 1 } AtmfAtmStatsEntry ::= SEQUENCE { atmfAtmStatsIndex Integer32, atmfAtmStatsReceivedCells Counter32, atmfAtmStatsDroppedReceivedCells Counter32, atmfAtmStatsTransmittedCells Counter32 } atmfAtmStatsIndex OBJECT-TYPE SYNTAX Integer32(0..2147483647) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This object should not be implemented except as required for backward compatibility with version 3.1 of the UNI specification." ::= { atmfAtmStatsEntry 1 } atmfAtmStatsReceivedCells OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This object should not be implemented except as required for backward compatibility with version 3.1 of the UNI specification." ::= { atmfAtmStatsEntry 2 } atmfAtmStatsDroppedReceivedCells OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This object should not be implemented except as required for backward compatibility with version 3.1 of the UNI specification." ::= { atmfAtmStatsEntry 3 } atmfAtmStatsTransmittedCells OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This object should not be implemented except as required for backward compatibility with version 3.1 of the UNI specification." ::= { atmfAtmStatsEntry 4 } -- The Virtual Path Group -- This group is mandatory for all ATM Interfaces. -- -- Information concerning Virtual Path Connections atmfVpcTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmfVpcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of status and parameter information on the virtual path connections which cross this ATM Interface. There is one entry in this table for each permanent virtual path connection." ::= { atmfVpcGroup 1 } atmfVpcEntry OBJECT-TYPE SYNTAX AtmfVpcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table, containing information about a particular virtual path connection." INDEX { atmfVpcPortIndex, atmfVpcVpi } ::= { atmfVpcTable 1 } AtmfVpcEntry ::= SEQUENCE { atmfVpcPortIndex Integer32, atmfVpcVpi Integer32, atmfVpcOperStatus INTEGER, atmfVpcTransmitTrafficDescriptorType OBJECT IDENTIFIER, atmfVpcTransmitTrafficDescriptorParam1 Integer32, atmfVpcTransmitTrafficDescriptorParam2 Integer32, atmfVpcTransmitTrafficDescriptorParam3 Integer32, atmfVpcTransmitTrafficDescriptorParam4 Integer32, atmfVpcTransmitTrafficDescriptorParam5 Integer32, atmfVpcReceiveTrafficDescriptorType OBJECT IDENTIFIER, atmfVpcReceiveTrafficDescriptorParam1 Integer32, atmfVpcReceiveTrafficDescriptorParam2 Integer32, atmfVpcReceiveTrafficDescriptorParam3 Integer32, atmfVpcReceiveTrafficDescriptorParam4 Integer32, atmfVpcReceiveTrafficDescriptorParam5 Integer32, atmfVpcQoSCategory INTEGER, atmfVpcTransmitQoSClass Integer32, atmfVpcReceiveQoSClass Integer32, atmfVpcBestEffortIndicator TruthValue, atmfVpcServiceCategory AtmServiceCategory } atmfVpcPortIndex OBJECT-TYPE SYNTAX Integer32(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of 0 which has the special meaning of identifying the ATM Interface over which this message was received." ::= { atmfVpcEntry 1 } atmfVpcVpi OBJECT-TYPE SYNTAX Integer32(0..4095) MAX-ACCESS read-only STATUS current DESCRIPTION "The VPI value of this Virtual Path Connection at the local ATM Interface." ::= { atmfVpcEntry 2 } atmfVpcOperStatus OBJECT-TYPE SYNTAX INTEGER { unknown(1), end2endUp(2), end2endDown(3), localUpEnd2endUnknown(4), localDown(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The present actual operational status of the VPC. A value of end2endUp(2) or end2endDown(3) would be used if the end-to-end status is known. If only local status information is available, a value of localUpEnd2endUnknown(4) or localDown(5) would be used." ::= { atmfVpcEntry 3 } atmfVpcTransmitTrafficDescriptorType OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION "The type of traffic management, applicable to the transmit direction of this VPC. The type may indicate none, or a type with one or more parameters. These parameters are specified as a parameter vector, in the corresponding instances of the objects: atmfVpcTransmitTrafficDescriptorParam1, atmfVpcTransmitTrafficDescriptorParam2, atmfVpcTransmitTrafficDescriptorParam3, atmfVpcTransmitTrafficDescriptorParam4, and atmfVpcTransmitTrafficDescriptorParam5." ::= { atmfVpcEntry 4 } atmfVpcTransmitTrafficDescriptorParam1 OBJECT-TYPE SYNTAX Integer32(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The first parameter of the transmit parameter vector for this VPC, used according to the value of atmfVpcTransmitTrafficDescriptorType." ::= { atmfVpcEntry 5 } atmfVpcTransmitTrafficDescriptorParam2 OBJECT-TYPE SYNTAX Integer32(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The second parameter of the transmit parameter vector for this VPC, used according to the value of atmfVpcTransmitTrafficDescriptorType." ::= { atmfVpcEntry 6 } atmfVpcTransmitTrafficDescriptorParam3 OBJECT-TYPE SYNTAX Integer32(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The third parameter of the transmit parameter vector for this VPC, used according to the value of atmfVpcTransmitTrafficDescriptorType." ::= { atmfVpcEntry 7 } atmfVpcTransmitTrafficDescriptorParam4 OBJECT-TYPE SYNTAX Integer32(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The fourth parameter of the transmit parameter vector for this VPC, used according to the value of atmfVpcTransmitTrafficDescriptorType." ::= { atmfVpcEntry 8 } atmfVpcTransmitTrafficDescriptorParam5 OBJECT-TYPE SYNTAX Integer32(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The fifth parameter of the transmit parameter vector for this VPC, used according to the value of atmfVpcTransmitTrafficDescriptorType." ::= { atmfVpcEntry 9 } atmfVpcReceiveTrafficDescriptorType OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION "The type of traffic management, applicable to the traffic in the receive direction of this VPC. The type may indicate none, or a type with one or more parameters. These parameters are specified as a parameter vector, in the corresponding instances of the objects: atmfVpcReceiveTrafficDescriptorParam1, atmfVpcReceiveTrafficDescriptorParam2, atmfVpcReceiveTrafficDescriptorParam3, atmfVpcReceiveTrafficDescriptorParam4, and atmfVpcReceiveTrafficDescriptorParam5." ::= { atmfVpcEntry 10 } atmfVpcReceiveTrafficDescriptorParam1 OBJECT-TYPE SYNTAX Integer32(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The first parameter of the receive parameter vector for this VPC, used according to the value of atmfVpcReceiveTrafficDescriptorType." ::= { atmfVpcEntry 11 } atmfVpcReceiveTrafficDescriptorParam2 OBJECT-TYPE SYNTAX Integer32(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The second parameter of the receive parameter vector for this VPC, used according to the value of atmfVpcReceiveTrafficDescriptorType." ::= { atmfVpcEntry 12 } atmfVpcReceiveTrafficDescriptorParam3 OBJECT-TYPE SYNTAX Integer32(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The third parameter of the receive parameter vector for this VPC, used according to the value of atmfVpcReceiveTrafficDescriptorType." ::= { atmfVpcEntry 13 } atmfVpcReceiveTrafficDescriptorParam4 OBJECT-TYPE SYNTAX Integer32(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The fourth parameter of the receive parameter vector for this VPC, used according to the value of atmfVpcReceiveTrafficDescriptorType." ::= { atmfVpcEntry 14 } atmfVpcReceiveTrafficDescriptorParam5 OBJECT-TYPE SYNTAX Integer32(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The fifth parameter of the receive parameter vector for this VPC, used according to the value of atmfVpcReceiveTrafficDescriptorType." ::= { atmfVpcEntry 15 } atmfVpcQoSCategory OBJECT-TYPE SYNTAX INTEGER { other(1), deterministic (2), statistical (3), unspecified (4) } MAX-ACCESS read-only STATUS obsolete DESCRIPTION "This object should not be implemented except as required for backward compatibility with version 2.0 of the UNI specification." ::= { atmfVpcEntry 16 } atmfVpcTransmitQoSClass OBJECT-TYPE SYNTAX Integer32(0..255) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This object should not be implemented except as required for backward compatibility with version 3.1 of the UNI specification." ::= { atmfVpcEntry 17 } atmfVpcReceiveQoSClass OBJECT-TYPE SYNTAX Integer32(0..255) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This object should not be implemented except as required for backward compatibility with version 3.1 of the UNI specification." ::= { atmfVpcEntry 18 } atmfVpcBestEffortIndicator OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "The object is examined when atmfVpcTransmitTrafficDescriptorType or atmfVpcReceiveTrafficDescriptorType for the associated connection is equal to atmfNoClpNoScr. If this object is set to false(2), the network is requested to apply the CBR.1 conformance definition. If this object is set to true(1), the network is requested to apply the UBR.1 conformance definition." ::= { atmfVpcEntry 19 } atmfVpcServiceCategory OBJECT-TYPE SYNTAX AtmServiceCategory MAX-ACCESS read-only STATUS current DESCRIPTION "The service category of this virtual path connection." ::= { atmfVpcEntry 20 } -- -- The Virtual Path ABR Group -- This group contains per-VPC information, support for which is optional. -- -- Attributes of ABR Virtual Path connections -- -- atmfVpcAbrTable OBJECT-TYPE -- SYNTAX SEQUENCE OF AtmfVpcAbrEntry -- ACCESS not-accessible -- STATUS mandatory -- DESCRIPTION -- "A table of operational parameters related to the ABR -- virtual path connections which cross this ATM -- Interface. There is one entry in this table for each -- ABR virtual path connection. -- -- Each virtual path connection represented -- in this table must also be represented by -- an entry in the atmfVpcTable." -- ::= { atmfVpcAbrGroup 1 } -- -- atmfVpcAbrEntry OBJECT-TYPE -- SYNTAX AtmfVpcAbrEntry -- ACCESS not-accessible -- STATUS mandatory -- DESCRIPTION -- "An entry in the table, containing information about a -- particular ABR virtual path connection." -- INDEX { atmfVpcAbrPortIndex, atmfVpcAbrVpi } -- ::= { atmfVpcAbrTable 1 } -- -- AtmfVpcAbrEntry ::= -- SEQUENCE { -- atmfVpcAbrPortIndex -- INTEGER, -- atmfVpcAbrVpi -- INTEGER, -- atmfVpcAbrTransmitIcr -- INTEGER, -- atmfVpcAbrTransmitNrm -- INTEGER, -- atmfVpcAbrTransmitTrm -- INTEGER, -- atmfVpcAbrTransmitCdf -- INTEGER, -- atmfVpcAbrTransmitRif -- INTEGER, -- atmfVpcAbrTransmitRdf -- INTEGER, -- atmfVpcAbrTransmitAdtf -- INTEGER, -- atmfVpcAbrTransmitCrm -- INTEGER -- } -- -- atmfVpcAbrPortIndex OBJECT-TYPE -- SYNTAX Integer32(0..2147483647) -- ACCESS read-only -- STATUS mandatory -- DESCRIPTION -- "The value of 0 which has the special meaning of identifying -- the ATM Interface over which this message was received." -- ::= { atmfVpcAbrEntry 1 } -- -- atmfVpcAbrVpi OBJECT-TYPE -- SYNTAX Integer32(0..4095) -- ACCESS read-only -- STATUS mandatory -- DESCRIPTION -- "The VPI value of this ABR Virtual Path Connection at the -- local ATM Interface." -- ::= { atmfVpcAbrEntry 2 } -- -- atmfVpcAbrTransmitIcr OBJECT-TYPE -- SYNTAX Integer32(0..16777215) -- ACCESS read-only -- STATUS mandatory -- DESCRIPTION -- "Initial Cell Rate: This is the rate at which the -- source starts, both initially and after an idle period. -- The unit is cells per second. The value must not be -- larger than PCR, and is usually lower." -- ::= { atmfVpcAbrEntry 3 } -- -- atmfVpcAbrTransmitNrm OBJECT-TYPE -- SYNTAX INTEGER { -- nrm2(1), -- nrm4(2), -- nrm8(3), -- nrm16(4), -- nrm32(5), -- nrm64(6), -- nrm128(7), -- nrm256(8) -- } -- ACCESS read-only -- STATUS mandatory -- DESCRIPTION -- "The maximum number of data cells a source may send -- for each forward RM-cell. The default value is nrm32(5)." -- ::= { atmfVpcAbrEntry 4 } -- -- atmfVpcAbrTransmitTrm OBJECT-TYPE -- SYNTAX INTEGER { -- trm0point78125(1), -- trm1point5625(2), -- trm3point125(3), -- trm6point25(4), -- trm12point5(5), -- trm25(6), -- trm50(7), -- trm100(8) -- } -- ACCESS read-only -- STATUS mandatory -- DESCRIPTION -- "Upper bound on the time between forward RM-cells for -- an active source (in milliseconds). The default value -- is trm100(8)." -- ::= { atmfVpcAbrEntry 5 } -- -- atmfVpcAbrTransmitCdf OBJECT-TYPE -- SYNTAX INTEGER { -- cdf0(1), -- cdfOneOver64(2), -- cdfOneOver32(3), -- cdfOneOver16(4), -- cdfOneOver8(5), -- cdfOneOver4(6), -- cdfOneOver2(7), -- cdfOne(8) -- } -- ACCESS read-only -- STATUS mandatory -- DESCRIPTION -- "Cutoff Decrease Factor: This field controls the rate -- decrease associated with lost or delayed backward RM -- cells. Larger values result in faster rate decrease. -- The default value is cdfOneOver16(4)." -- ::= { atmfVpcAbrEntry 6 } -- -- atmfVpcAbrTransmitRif OBJECT-TYPE -- SYNTAX INTEGER { -- rifOneOver32768(1), -- rifOneOver16384(2), -- rifOneOver8192(3), -- rifOneOver4096(4), -- rifOneOver2048(5), -- rifOneOver1024(6), -- rifOneOver512(7), -- rifOneOver256(8), -- rifOneOver128(9), -- rifOneOver64(10), -- rifOneOver32(11), -- rifOneOver16(12), -- rifOneOver8(13), -- rifOneOver4(14), -- rifOneOver2(15), -- rifOne(16) -- } -- ACCESS read-only -- STATUS mandatory -- DESCRIPTION -- "Rate Increment Factor: Controls the rate at which the rate -- increases, when a backward RM-cell is received with CI=0 and -- NI=0. Larger values lead to faster rate increase. The default -- value is rifOneOver16(12)." -- ::= { atmfVpcAbrEntry 7 } -- -- atmfVpcAbrTransmitRdf OBJECT-TYPE -- SYNTAX INTEGER { -- rdfOneOver32768(1), -- rdfOneOver16384(2), -- rdfOneOver8192(3), -- rdfOneOver4096(4), -- rdfOneOver2048(5), -- rdfOneOver1024(6), -- rdfOneOver512(7), -- rdfOneOver256(8), -- rdfOneOver128(9), -- rdfOneOver64(10), -- rdfOneOver32(11), -- rdfOneOver16(12), -- rdfOneOver8(13), -- rdfOneOver4(14), -- rdfOneOver2(15), -- rdfOne(16) -- } -- ACCESS read-only -- STATUS mandatory -- DESCRIPTION -- "Rate Decrease Factor: Controls the rate decrease -- which occurs when backward RM-cells with CI=1, are -- received. Larger values lead to faster rate -- decrease. The default value is rdfOneOver16(12)." -- ::= { atmfVpcAbrEntry 8 } -- -- atmfVpcAbrTransmitAdtf OBJECT-TYPE -- SYNTAX Integer32(1..1023) -- ACCESS read-only -- STATUS mandatory -- DESCRIPTION -- "ACR Decrease Time Factor: Time permitted between -- sending RM-cells, before the allowed rate (ACR) is -- decreased to ICR. Range is 10 ms to 10.23 seconds. -- The unit is 10 milliseconds. For example, the default -- value of 50 corresponds to a time factor of 500 ms. -- Larger values allow a source to retain its current -- rate longer, during periods of relative inactivity. -- The default is 50 (0.5 seconds)." -- ::= { atmfVpcAbrEntry 9 } -- -- atmfVpcAbrTransmitCrm OBJECT-TYPE -- SYNTAX Integer32(0..8388608) -- ACCESS read-only -- STATUS mandatory -- DESCRIPTION -- "RM Cells Before Cutoff: Limits the number of forward -- RM-cells which may be sent in the absence of received -- backward RM-cells." -- ::= { atmfVpcAbrEntry 10 } -- -- -- The Virtual Channel Group -- This group is mandatory for all ATM Interfaces. -- -- Information concerning Virtual Channel Connections atmfVccTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmfVccEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of status and parameter information on the virtual channel connections which are visible at this ATM Interface. There is one entry in this table for each permanent virtual channel connection, including reserved VCCs that are supported; e.g., signalling, OAM flows, and ILMI, but not unassigned cells." ::= { atmfVccGroup 1 } atmfVccEntry OBJECT-TYPE SYNTAX AtmfVccEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table, containing information about a particular virtual channel connection." INDEX { atmfVccPortIndex, atmfVccVpi, atmfVccVci } ::= { atmfVccTable 1 } AtmfVccEntry ::= SEQUENCE { atmfVccPortIndex Integer32, atmfVccVpi Integer32, atmfVccVci Integer32, atmfVccOperStatus INTEGER, atmfVccTransmitTrafficDescriptorType OBJECT IDENTIFIER, atmfVccTransmitTrafficDescriptorParam1 Integer32, atmfVccTransmitTrafficDescriptorParam2 Integer32, atmfVccTransmitTrafficDescriptorParam3 Integer32, atmfVccTransmitTrafficDescriptorParam4 Integer32, atmfVccTransmitTrafficDescriptorParam5 Integer32, atmfVccReceiveTrafficDescriptorType OBJECT IDENTIFIER, atmfVccReceiveTrafficDescriptorParam1 Integer32, atmfVccReceiveTrafficDescriptorParam2 Integer32, atmfVccReceiveTrafficDescriptorParam3 Integer32, atmfVccReceiveTrafficDescriptorParam4 Integer32, atmfVccReceiveTrafficDescriptorParam5 Integer32, atmfVccQoSCategory INTEGER, atmfVccTransmitQoSClass Integer32, atmfVccReceiveQoSClass Integer32 -- atmfVccBestEffortIndicator -- TruthValue, -- atmfVccTransmitFrameDiscard -- TruthValue, -- atmfVccReceiveFrameDiscard -- TruthValue, -- atmfVccServiceCategory -- AtmServiceCategory } atmfVccPortIndex OBJECT-TYPE SYNTAX Integer32(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of 0 which has the special meaning of identifying the ATM Interface over which this message was received." ::= { atmfVccEntry 1 } atmfVccVpi OBJECT-TYPE SYNTAX Integer32(0..4095) MAX-ACCESS read-only STATUS current DESCRIPTION "The VPI value of this Virtual Channel Connection at the local ATM Interface. For virtual interfaces (i.e. Virtual Path Connections), this value has no meaning and is set to zero " ::= { atmfVccEntry 2 } atmfVccVci OBJECT-TYPE SYNTAX Integer32(0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The VCI value of this Virtual Channel Connection at the local ATM Interface." ::= { atmfVccEntry 3 } atmfVccOperStatus OBJECT-TYPE SYNTAX INTEGER { unknown(1), end2endUp(2), end2endDown(3), localUpEnd2endUnknown(4), localDown(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The present actual operational status of the VCC. A value of end2endUp(2) or end2endUp(3) is used if the end to end status is known. If only local status is known a value of localUpEnd2endUnknown(4) or localDown(5) is used." ::= { atmfVccEntry 4 } atmfVccTransmitTrafficDescriptorType OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION "The type of traffic management, applicable to the transmit direction of this VCC. The type may indicate none, or a type with one or more parameters. These parameters are specified as a parameter vector, in the corresponding instances of the objects: atmfVccTransmitTrafficDescriptorParam1, atmfVccTransmitTrafficDescriptorParam2, atmfVccTransmitTrafficDescriptorParam3, atmfVccTransmitTrafficDescriptorParam4, and atmfVccTransmitTrafficDescriptorParam5." ::= { atmfVccEntry 5 } atmfVccTransmitTrafficDescriptorParam1 OBJECT-TYPE SYNTAX Integer32(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The first parameter of the transmit parameter vector for this VCC, used according to the value of atmfVccTransmitTrafficDescriptorType." ::= { atmfVccEntry 6 } atmfVccTransmitTrafficDescriptorParam2 OBJECT-TYPE SYNTAX Integer32(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The second parameter of the transmit parameter vector for this VCC, used according to the value of atmfVccTransmitTrafficDescriptorType." ::= { atmfVccEntry 7 } atmfVccTransmitTrafficDescriptorParam3 OBJECT-TYPE SYNTAX Integer32(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The third parameter of the transmit parameter vector for this VCC, used according to the value of atmfVccTransmitTrafficDescriptorType." ::= { atmfVccEntry 8 } atmfVccTransmitTrafficDescriptorParam4 OBJECT-TYPE SYNTAX Integer32(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The fourth parameter of the transmit parameter vector for this VCC, used according to the value of atmfVccTransmitTrafficDescriptorType." ::= { atmfVccEntry 9 } atmfVccTransmitTrafficDescriptorParam5 OBJECT-TYPE SYNTAX Integer32(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The fifth parameter of the transmit parameter vector for this VCC, used according to the value of atmfVccTransmitTrafficDescriptorType." ::= { atmfVccEntry 10 } atmfVccReceiveTrafficDescriptorType OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION "The type of traffic management, applicable to the traffic in the receive direction of this VCC. The type may indicate none, or a type with one or more parameters. These parameters are specified as a parameter vector, in the corresponding instances of the objects: atmfVccReceiveTrafficDescriptorParam1, atmfVccReceiveTrafficDescriptorParam2, atmfVccReceiveTrafficDescriptorParam3, atmfVccReceiveTrafficDescriptorParam4, and atmfVccReceiveTrafficDescriptorParam5." ::= { atmfVccEntry 11 } atmfVccReceiveTrafficDescriptorParam1 OBJECT-TYPE SYNTAX Integer32(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The first parameter of the receive parameter vector for this VCC, used according to the value of atmfVccReceiveTrafficDescriptorType." ::= { atmfVccEntry 12 } atmfVccReceiveTrafficDescriptorParam2 OBJECT-TYPE SYNTAX Integer32(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The second parameter of the receive parameter vector for this VCC, used according to the value of atmfVccReceiveTrafficDescriptorType." ::= { atmfVccEntry 13 } atmfVccReceiveTrafficDescriptorParam3 OBJECT-TYPE SYNTAX Integer32(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The third parameter of the receive parameter vector for this VCC, used according to the value of atmfVccReceiveTrafficDescriptorType." ::= { atmfVccEntry 14 } atmfVccReceiveTrafficDescriptorParam4 OBJECT-TYPE SYNTAX Integer32(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The fourth parameter of the receive parameter vector for this VCC, used according to the value of atmfVccReceiveTrafficDescriptorType." ::= { atmfVccEntry 15 } atmfVccReceiveTrafficDescriptorParam5 OBJECT-TYPE SYNTAX Integer32(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The fifth parameter of the receive parameter vector for this VCC, used according to the value of atmfVccReceiveTrafficDescriptorType." ::= { atmfVccEntry 16 } atmfVccQoSCategory OBJECT-TYPE SYNTAX INTEGER { other(1), deterministic(2), statistical(3), unspecified(4) } MAX-ACCESS read-only STATUS obsolete DESCRIPTION "This object should not be implemented except as required for backward compatibility with version 2.0 of the UNI specification." ::= { atmfVccEntry 17 } atmfVccTransmitQoSClass OBJECT-TYPE SYNTAX Integer32(0..255) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This object should not be implemented except as required for backward compatibility with version 3.1 of the UNI specification." ::= { atmfVccEntry 18 } atmfVccReceiveQoSClass OBJECT-TYPE SYNTAX Integer32(0..255) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This object should not be implemented except as required for backward compatibility with version 3.1 of the UNI specification." ::= { atmfVccEntry 19 } -- atmfVccBestEffortIndicator OBJECT-TYPE -- SYNTAX TruthValue -- ACCESS read-only -- STATUS mandatory -- DESCRIPTION -- "The object is examined when -- atmfVccTransmitTrafficDescriptorType or -- atmfVccReceiveTrafficDescriptorType for the associated -- connection is equal to atmfNoClpNoScr. -- If this object is set to false(2), the network is requested -- to apply the CBR.1 conformance definition. If this object -- is set to true(1), the network is requested to apply the -- UBR.1 conformance definition." -- ::= { atmfVccEntry 20 } -- -- atmfVccTransmitFrameDiscard OBJECT-TYPE -- SYNTAX TruthValue -- ACCESS read-only -- STATUS mandatory -- DESCRIPTION -- "If set to true(1), this object indicates that the network -- is requested to treat data for this connection (in the -- transmit direction) as frames (e.g. AAL5 CPCS_PDU's) rather -- than as individual cells. While the precise -- implementation is network-specific, this treatment may -- for example involve discarding entire frames during -- congestion, rather than a few cells from many frames. -- The default value is false(2)." -- ::= { atmfVccEntry 21 } -- -- atmfVccReceiveFrameDiscard OBJECT-TYPE -- SYNTAX TruthValue -- ACCESS read-only -- STATUS mandatory -- DESCRIPTION -- "If set to true(1), this object indicates that the network -- is requested to treat data for this connection (in the -- receive direction) as frames (e.g. AAL5 CPCS_PDU's) rather -- than as individual cells. While the precise -- implementation is network-specific, this treatment may -- for example involve discarding entire frames during -- congestion, rather than a few cells from many frames. -- The default value is false(2)." -- ::= { atmfVccEntry 22 } -- -- atmfVccServiceCategory OBJECT-TYPE -- SYNTAX AtmServiceCategory -- ACCESS read-only -- STATUS mandatory -- DESCRIPTION -- "The service category of this virtual channel connection." -- ::= { atmfVccEntry 23 } -- -- -- The Virtual Channel ABR Group -- This group contains per-VCC information, support for which is optional. -- -- Attributes of ABR Virtual Channel connections -- -- atmfVccAbrTable OBJECT-TYPE -- SYNTAX SEQUENCE OF AtmfVccAbrEntry -- ACCESS not-accessible -- STATUS mandatory -- DESCRIPTION -- "A table of operational parameters related to the ABR -- virtual channel connections which cross this ATM -- Interface. There is one entry in this table for each -- ABR virtual channel connection. -- -- Each virtual channel connection represented -- in this table must also be represented by -- an entry in the atmfVccTable." -- ::= { atmfVccAbrGroup 1 } -- -- atmfVccAbrEntry OBJECT-TYPE -- SYNTAX AtmfVccAbrEntry -- ACCESS not-accessible -- STATUS mandatory -- DESCRIPTION -- "An entry in the table, containing information about a -- particular ABR virtual channel connection." -- INDEX { atmfVccAbrPortIndex, atmfVccAbrVpi, atmfVccAbrVci } -- ::= { atmfVccAbrTable 1 } -- -- AtmfVccAbrEntry ::= -- SEQUENCE { -- atmfVccAbrPortIndex -- Integer32, -- atmfVccAbrVpi -- Integer32, -- atmfVccAbrVci -- Integer32, -- atmfVccAbrTransmitIcr -- Integer32, -- atmfVccAbrTransmitNrm -- Integer32, -- atmfVccAbrTransmitTrm -- Integer32, -- atmfVccAbrTransmitCdf -- Integer32, -- atmfVccAbrTransmitRif -- Integer32, -- atmfVccAbrTransmitRdf -- Integer32, -- atmfVccAbrTransmitAdtf -- Integer32, -- atmfVccAbrTransmitCrm -- INTEGER -- } -- -- atmfVccAbrPortIndex OBJECT-TYPE -- SYNTAX Integer32(0..2147483647) -- ACCESS read-only -- STATUS mandatory -- DESCRIPTION -- "The value of 0 which has the special meaning of identifying -- the ATM Interface over which this message was received." -- ::= { atmfVccAbrEntry 1 } -- -- atmfVccAbrVpi OBJECT-TYPE -- SYNTAX Integer32(0..4095) -- ACCESS read-only -- STATUS mandatory -- DESCRIPTION -- "The VPI value of this ABR Virtual Channel Connection at the -- local ATM Interface. For virtual interfaces (i.e. Virtual Path -- Connections), this value has no meaning and is set to zero " -- ::= { atmfVccAbrEntry 2 } -- -- atmfVccAbrVci OBJECT-TYPE -- SYNTAX Integer32(0..65535) -- ACCESS read-only -- STATUS mandatory -- DESCRIPTION -- "The VCI value of this ABR Virtual Channel Connection at the -- local ATM Interface." -- ::= { atmfVccAbrEntry 3 } -- -- atmfVccAbrTransmitIcr OBJECT-TYPE -- SYNTAX Integer32(0..16777215) -- ACCESS read-only -- STATUS mandatory -- DESCRIPTION -- "Initial Cell Rate: This is the rate at which the -- source starts, both initially and after an idle period. -- The unit is cells per second. The value must not be -- larger than PCR, and is usually lower." -- ::= { atmfVccAbrEntry 4 } -- -- atmfVccAbrTransmitNrm OBJECT-TYPE -- SYNTAX INTEGER { -- nrm2(1), -- nrm4(2), -- nrm8(3), -- nrm16(4), -- nrm32(5), -- nrm64(6), -- nrm128(7), -- nrm256(8) -- } -- ACCESS read-only -- STATUS mandatory -- DESCRIPTION -- "The maximum number of data cells a source may send -- for each forward RM-cell. The default value is nrm32(5)." -- ::= { atmfVccAbrEntry 5 } -- -- atmfVccAbrTransmitTrm OBJECT-TYPE -- SYNTAX INTEGER { -- trm0point78125(1), -- trm1point5625(2), -- trm3point125(3), -- trm6point25(4), -- trm12point5(5), -- trm25(6), -- trm50(7), -- trm100(8) -- } -- ACCESS read-only -- STATUS mandatory -- DESCRIPTION -- "Upper bound on the time between forward RM-cells for -- an active source (in milliseconds). The default value -- is trm100(8)." -- ::= { atmfVccAbrEntry 6 } -- -- atmfVccAbrTransmitCdf OBJECT-TYPE -- SYNTAX INTEGER { -- cdf0(1), -- cdfOneOver64(2), -- cdfOneOver32(3), -- cdfOneOver16(4), -- cdfOneOver8(5), -- cdfOneOver4(6), -- cdfOneOver2(7), -- cdfOne(8) -- } -- ACCESS read-only -- STATUS mandatory -- DESCRIPTION -- "Cutoff Decrease Factor: This field controls the rate -- decrease associated with lost or delayed backward RM -- cells. Larger values result in faster rate decrease. -- The default value is cdfOneOver16(4)." -- ::= { atmfVccAbrEntry 7 } -- -- atmfVccAbrTransmitRif OBJECT-TYPE -- SYNTAX INTEGER { -- rifOneOver32768(1), -- rifOneOver16384(2), -- rifOneOver8192(3), -- rifOneOver4096(4), -- rifOneOver2048(5), -- rifOneOver1024(6), -- rifOneOver512(7), -- rifOneOver256(8), -- rifOneOver128(9), -- rifOneOver64(10), -- rifOneOver32(11), -- rifOneOver16(12), -- rifOneOver8(13), -- rifOneOver4(14), -- rifOneOver2(15), -- rifOne(16) -- } -- ACCESS read-only -- STATUS mandatory -- DESCRIPTION -- "Rate Increment Factor: Controls the rate at which the rate -- increases, when a backward RM-cell is received with CI=0 and -- NI=0. Larger values lead to faster rate increase. The default -- value is rifOneOver16(12)." -- ::= { atmfVccAbrEntry 8 } -- -- atmfVccAbrTransmitRdf OBJECT-TYPE -- SYNTAX INTEGER { -- rdfOneOver32768(1), -- rdfOneOver16384(2), -- rdfOneOver8192(3), -- rdfOneOver4096(4), -- rdfOneOver2048(5), -- rdfOneOver1024(6), -- rdfOneOver512(7), -- rdfOneOver256(8), -- rdfOneOver128(9), -- rdfOneOver64(10), -- rdfOneOver32(11), -- rdfOneOver16(12), -- rdfOneOver8(13), -- rdfOneOver4(14), -- rdfOneOver2(15), -- rdfOne(16) -- } -- ACCESS read-only -- STATUS mandatory -- DESCRIPTION -- "Rate Decrease Factor: Controls the rate decrease -- which occurs when backward RM-cells with CI=1, are -- received. Larger values lead to faster rate -- decrease. The default value is rdfOneOver16(12)." -- ::= { atmfVccAbrEntry 9 } -- -- atmfVccAbrTransmitAdtf OBJECT-TYPE -- SYNTAX Integer32(1..1023) -- ACCESS read-only -- STATUS mandatory -- DESCRIPTION -- "ACR Decrease Time Factor: Time permitted between -- sending RM-cells, before the allowed rate (ACR) is -- decreased to ICR. Range is 10 ms to 10.23 seconds. -- The unit is 10 milliseconds. For example, the default -- value of 50 corresponds to a time factor of 500 ms. -- Larger values allow a source to retain its current -- rate longer, during periods of relative inactivity. -- The default is 50 (0.5 seconds)." -- ::= { atmfVccAbrEntry 10 } -- -- atmfVccAbrTransmitCrm OBJECT-TYPE -- SYNTAX Integer32(0..8388608) -- ACCESS read-only -- STATUS mandatory -- DESCRIPTION -- "RM Cells Before Cutoff: Limits the number of forward -- RM-cells which may be sent in the absence of received -- backward RM-cells." -- ::= { atmfVccAbrEntry 11 } -- -- -- Traps -- atmfVpcChange TRAP-TYPE -- ENTERPRISE atmForum -- VARIABLES { atmfVpcPortIndex, atmfVpcVpi, atmfVpcOperStatus } -- DESCRIPTION -- "An atmfVpcChange trap indicates that a permanent VPC has been -- added or deleted at this ATM Interface or that the attributes -- of an existing VPC have been modified. The variables -- included in the trap identify the VPI value of the -- reconfigured VPC at this ATM Interface." -- ::= 1 -- -- atmfVccChange TRAP-TYPE -- ENTERPRISE atmForum -- VARIABLES { atmfVccPortIndex, atmfVccVci, atmfVccVpi, -- atmfVccOperStatus } -- DESCRIPTION -- "An atmfVccChange trap indicates that a permanent VCC has been -- added or deleted at this ATM Interface or that the attributes -- of an existing VCC have been modified.. The variables -- included in the trap identify the VCI and VPI values -- of the reconfigured VCC at this ATM -- Interface." -- ::= 2 -- -- END -- -- ATM-FORUM-ADDR-REG DEFINITIONS ::= BEGIN -- -- IMPORTS -- atmfNetPrefixGroup, -- atmfAddressGroup, -- atmfAddressRegistrationAdminGroup, -- AtmAddress, -- NetPrefix FROM ATM-FORUM-TC-MIB -- OBJECT-TYPE FROM RFC-1212; -- -- -- The NetPrefix Group -- -- The Network Prefix Table is implemented by the user-side IME. -- -- atmfNetPrefixTable OBJECT-TYPE -- SYNTAX SEQUENCE OF AtmfNetPrefixEntry -- ACCESS not-accessible -- STATUS mandatory -- DESCRIPTION -- "A table implemented by the user-side IME, containing the -- network-prefix(es) for ATM-layer addresses in effect on -- the user side of the UNI." -- ::= { atmfNetPrefixGroup 1 } -- -- atmfNetPrefixEntry OBJECT-TYPE -- SYNTAX AtmfNetPrefixEntry -- ACCESS not-accessible -- STATUS mandatory -- DESCRIPTION -- "Information about a single network-prefix for -- ATM-layer addresses in effect on the user-side IME. -- Note that the index variable atmNetPrefixPrefix is a -- variable-length string, and as such the rule for -- variable-length strings in section 4.1.6 of RFC 1212 -- applies." -- -- INDEX { atmfNetPrefixPort, atmfNetPrefixPrefix } -- ::= { atmfNetPrefixTable 1 } -- -- AtmfNetPrefixEntry ::= -- SEQUENCE { -- atmfNetPrefixPort -- Integer32, -- atmfNetPrefixPrefix -- NetPrefix, -- atmfNetPrefixStatus -- INTEGER -- } -- -- atmfNetPrefixPort OBJECT-TYPE -- SYNTAX Integer32(0..2147483647) -- ACCESS not-accessible -- STATUS mandatory -- DESCRIPTION -- "A unique value which identifies the UNI port for -- which the network prefix for ATM addresses is in -- effect. The value of 0 has the special meaning of -- identifying the local UNI." -- ::= { atmfNetPrefixEntry 1 } -- -- atmfNetPrefixPrefix OBJECT-TYPE -- SYNTAX NetPrefix -- ACCESS not-accessible -- STATUS mandatory -- DESCRIPTION -- "The network prefix for ATM addresses which is in -- effect on the user side of the ATM UNI port." -- ::= { atmfNetPrefixEntry 2 } -- -- atmfNetPrefixStatus OBJECT-TYPE -- SYNTAX INTEGER { valid(1), invalid(2) } -- ACCESS read-write -- STATUS mandatory -- DESCRIPTION -- "An indication of the validity of the network prefix -- for ATM addresses on the user side of the UNI port. -- To configure a new network prefix in this table, the -- network-side IME must set the appropriate instance of this -- object to the value valid(1). To delete an existing -- network prefix in this table, the network-side IME must -- set the appropriate instance of this object to the -- value invalid(2). -- -- If circumstances occur on the user-side IME which cause a -- prefix to become invalid, the user-side IME modifies the -- value of the appropriate instance of this object to invalid(2). -- -- Whenever the value of this object for a particular -- prefix becomes invalid(2), the conceptual row for that -- prefix may be removed from the table at any time, -- either immediately or subsequently." -- ::= { atmfNetPrefixEntry 3 } -- -- -- The Address Group -- -- The Address Table is implemented by the network-side IME. atmfAddressTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmfAddressEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table implemented by the network-side IME, containing the ATM-layer addresses in effect on the user side of the UNI." ::= { atmfAddressGroup 1 } atmfAddressEntry OBJECT-TYPE SYNTAX AtmfAddressEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about a single ATM-layer address in effect on the user-side IME. Note that the index variable atmAddressAtmAddress is a variable-length string, and as such the rule for variable-length strings in section 4.1.6 of RFC 1212 applies." INDEX { atmfAddressPort, atmfAddressAtmAddress } ::= { atmfAddressTable 1 } AtmfAddressEntry ::= SEQUENCE { atmfAddressPort Integer32, atmfAddressAtmAddress AtmAddress, atmfAddressStatus INTEGER, atmfAddressOrgScope INTEGER } atmfAddressPort OBJECT-TYPE SYNTAX Integer32(0..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A unique value which identifies the UNI port for which the ATM address is in effect. The value of 0 has the special meaning of identifying the local UNI." ::= { atmfAddressEntry 1 } atmfAddressAtmAddress OBJECT-TYPE SYNTAX AtmAddress MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ATM address which is in effect on the user side of the ATM UNI port." ::= { atmfAddressEntry 2 } atmfAddressStatus OBJECT-TYPE SYNTAX INTEGER { valid(1), invalid(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "An indication of the validity of the ATM address at the user side of the UNI port. To configure a new address in this table, the user-side IME must set the appropriate instance of this object to the value valid(1). To delete an existing address in this table, the user-side IME must set the appropriate instance of this object to the value invalid(2). If circumstances occur on the network-side IME which cause an address to become invalid, the network-side IME modifies the value of the appropriate instance of this object to invalid(2). Whenever the value of this object for a particular address becomes invalid(2), the conceptual row for that address may be removed from the table at any time, either immediately or subsequently." ::= { atmfAddressEntry 3 } atmfAddressOrgScope OBJECT-TYPE SYNTAX INTEGER { localNetwork(1), localNetworkPlusOne(2), localNetworkPlusTwo(3), siteMinusOne(4), intraSite(5), sitePlusOne(6), organizationMinusOne(7), intraOrganization(8), organizationPlusOne(9), communityMinusOne(10), intraCommunity(11), communityPlusOne(12), regional(13), interRegional(14), global(15) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the organizational scope for the referenced address. The information of the referenced address shall not be distributed outside the indicated scope. If the user-side IME does not specify a value for the atmfAddressOrgScope object, the network shall set the value of this object to localNetwork(1), if the registered address is an ATM group address, or to global(15), if the registered address is an individual address. Refer to Annex 6.0 of ATM Forum UNI Signalling 4.0 for guidelines regarding the use of organizational scopes. This organization hierarchy may be mapped to ATM network's routing hierarchy such as PNNI's routing level and the mapping shall be configurable in nodes. Use of this object in a public network is for further study. The default values for organizational scope are localNetwork(1) for ATM group addresses, and global(15) for individual addresses." ::= { atmfAddressEntry 4 } -- The Address Registration Admin Group -- -- The Address Registration Admin Table is mandatory for all IMEs. atmfAddressRegistrationAdminTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmfAddressRegistrationAdminEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of Address Registration administrative information for the ATM Interface." ::= { atmfAddressRegistrationAdminGroup 1 } atmfAddressRegistrationAdminEntry OBJECT-TYPE SYNTAX AtmfAddressRegistrationAdminEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table, containing Address Registration administrative information for the ATM Interface." INDEX { atmfAddressRegistrationAdminIndex } ::= { atmfAddressRegistrationAdminTable 1 } AtmfAddressRegistrationAdminEntry ::= SEQUENCE { atmfAddressRegistrationAdminIndex Integer32, atmfAddressRegistrationAdminStatus INTEGER } atmfAddressRegistrationAdminIndex OBJECT-TYPE SYNTAX Integer32(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of 0 which has the special meaning of identifying the ATM Interface over which this message was received." ::= { atmfAddressRegistrationAdminEntry 1 } atmfAddressRegistrationAdminStatus OBJECT-TYPE SYNTAX INTEGER { supported(1), unsupported(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "An indication of whether or not Address Registration is supported on this ATM Interface. Supported(1) indicates that this ATM Interface supports address registration. Unsupported(2) indicates that this ATM Interface does not support address registration." ::= { atmfAddressRegistrationAdminEntry 2 } -- END -- -- ATM-FORUM-SRVC-REG DEFINITIONS ::= BEGIN -- -- IMPORTS -- atmfSrvcRegTypes, -- atmfSrvcRegistryGroup, -- AtmAddress FROM ATM-FORUM-TC-MIB -- OBJECT-TYPE FROM RFC-1212; -- -- -- Object Identifier definitions -- -- The following values are defined for use as possible values -- of the atmfSrvcRegServiceID object. -- LAN Emulation Configuration Server (LECS) atmfSrvcRegLecs OBJECT IDENTIFIER ::= { atmfSrvcRegTypes 1 } -- When atmfSrvcRegServiceID has a value of atmfSrvcRegLecs, -- the value of atmfSrvcRegParm1 is ignored. -- ATM Name Server (ANS) atmfSrvcRegAns OBJECT IDENTIFIER ::= { atmfSrvcRegTypes 2 } -- When atmfSrvcRegServiceID has a value of atmfSrvcRegAns, -- the value of atmfSrvcRegParm1 is ignored. -- -- -- The Service Registry Table -- -- The Service Registry Table is implemented by the network-side IME atmfSrvcRegTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmfSrvcRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table implemented by the IME on the network side of the ATM UNI port contains all of the services that are available to the user-side IME indexed by service identifier." ::= { atmfSrvcRegistryGroup 1 } atmfSrvcRegEntry OBJECT-TYPE SYNTAX AtmfSrvcRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about a single service provider that is available to the user-side IME." INDEX { atmfSrvcRegPort, atmfSrvcRegServiceID, atmfSrvcRegAddressIndex } ::= { atmfSrvcRegTable 1 } AtmfSrvcRegEntry ::= SEQUENCE { atmfSrvcRegPort Integer32, atmfSrvcRegServiceID OBJECT IDENTIFIER, atmfSrvcRegATMAddress AtmAddress, atmfSrvcRegAddressIndex Integer32, atmfSrvcRegParm1 OCTET STRING } atmfSrvcRegPort OBJECT-TYPE SYNTAX Integer32(0..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The value of 0 which has the special meaning of identifying the ATM Interface over which this message was received." ::= { atmfSrvcRegEntry 1 } atmfSrvcRegServiceID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is the service identifier which uniquely identifies the type of service at the address provided in the table." ::= { atmfSrvcRegEntry 2 } atmfSrvcRegATMAddress OBJECT-TYPE SYNTAX AtmAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This is the full address of the service. The user-side IME may use this address to establish a connection with the service." ::= { atmfSrvcRegEntry 3 } atmfSrvcRegAddressIndex OBJECT-TYPE SYNTAX Integer32(1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "An arbitrary integer to differentiate multiple rows containing different ATM addresses for the same service on the same port." ::= { atmfSrvcRegEntry 4 } atmfSrvcRegParm1 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "An octet string whose size and meaning is determined by the value of atmfSrvcRegServiceID." ::= { atmfSrvcRegEntry 5 } END