-- MIB File Generated on 10-Feb-1998 at 15:10:44 HDM-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises, experimental, IpAddress, TimeTicks, Gauge, Counter FROM RFC1155-SMI DisplayString FROM RFC1213-MIB OBJECT-TYPE FROM RFC-1212; usr OBJECT IDENTIFIER ::= { enterprises 429 } nas OBJECT IDENTIFIER ::= { usr 1 } hdm OBJECT IDENTIFIER ::= { nas 22 } -- The modem Line Interface Group hdmLi OBJECT IDENTIFIER ::= { hdm 1 } hdmLiTable OBJECT-TYPE SYNTAX SEQUENCE OF HdmLiEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of configurable Line Interface objects for a modem. The number of table entries is given by modemNumber." ::= { hdmLi 1 } hdmLiEntry OBJECT-TYPE SYNTAX HdmLiEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Objects which define the line interface characteristics for a particualar modem." INDEX { hdmLiIndex, hdmLiIndex2 } ::= { hdmLiTable 1 } HdmLiEntry ::= SEQUENCE { hdmLiIndex INTEGER, hdmLiIndex2 INTEGER, hdmLiDialPause INTEGER, hdmLiCarrierRecDelay INTEGER, hdmLiCarrierLoss INTEGER, hdmLiToneDialTiming INTEGER, hdmLiGuardTone INTEGER, hdmLiAnswerTone INTEGER } hdmLiIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Index into the Line Interface table. This index is the value from the chassis mib entity relation table that is applicable for a particular modem." ::= { hdmLiEntry 1 } hdmLiIndex2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Secondary Index into the Line Interface table. This index is the value from the chassis mib entity relation table that is applicable for a particular modem." ::= { hdmLiEntry 2 } hdmLiDialPause OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Duration in seconds for the pause(') option in the dial command and the pause between command re-executions(> and A>) Default = 2. Equates to the modem's S8 register." ::= { hdmLiEntry 3 } hdmLiCarrierRecDelay OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Duration in 10ths of a second that the remote modem's carrier signal must be present before recognition. Ignored at speeds above 2400. Equates to the modem's S9 register. Default=6." ::= { hdmLiEntry 4 } hdmLiCarrierLoss OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Duration in 10ths of a second the modem waits after loss of carrier before hanging up. This allows the modem to distinguish between a momentary lapse in line quality and a true disconnect. When equal to 255 the modem will remain off hook until DTR drops or an ATH command is recieved. Equates to the modem's S10 register. Default=7." ::= { hdmLiEntry 5 } hdmLiToneDialTiming OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Duration and spacing in milliseconds of dialed Touch Tones. Equates to the modem's S10 register. Default=70." ::= { hdmLiEntry 6 } hdmLiGuardTone OBJECT-TYPE SYNTAX INTEGER{ none(1), european550(2), uk1800(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is required for modems answering calls that originate from sites outside of North America. The modem's must be operating in either 1200 or 2400 bps and be using the V.32 answer sequence. This object defines what guard tone is used for answering calls. This object equates to the &G register in US Robotics modems. Default=none." ::= { hdmLiEntry 7 } hdmLiAnswerTone OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Disables the 2100 Hz Answer tone allowing V.42 modems to connect more quickly and/or eliminating problems with older 2400-bps modems that do not recognise this tone. Equates to the modem's S27.3 register. Default=Enabled." ::= { hdmLiEntry 8 } -- The modem Data Compression group hdmDc OBJECT IDENTIFIER ::= { hdm 2 } hdmDcTable OBJECT-TYPE SYNTAX SEQUENCE OF HdmDcEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of configurable objects that define the operation of Data Compression in the modem." ::= { hdmDc 1 } hdmDcEntry OBJECT-TYPE SYNTAX HdmDcEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Objects which define Data Compression operation for a modem." INDEX { hdmDcIndex, hdmDcIndex2 } ::= { hdmDcTable 1 } HdmDcEntry ::= SEQUENCE { hdmDcIndex INTEGER, hdmDcIndex2 INTEGER, hdmDcDataCompression INTEGER } hdmDcIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index into the Data Compression table. This object contains the unique value for this modem as defined in the chassis mib entity relation table." ::= { hdmDcEntry 1 } hdmDcIndex2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The Secondary index into the Data Compression table. This object contains the unique value for this modem as defined in the chassis mib entity relation table." ::= { hdmDcEntry 2 } hdmDcDataCompression OBJECT-TYPE SYNTAX INTEGER{ none(1), autoEnable(2), enable(3), mnpWoCompression(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines when and how data compression is enabled. Corresponds to the &K register in USR modems." ::= { hdmDcEntry 3 } -- The modem Signal Converter group hdmSc OBJECT IDENTIFIER ::= { hdm 3 } hdmScTable OBJECT-TYPE SYNTAX SEQUENCE OF HdmScEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of configurable objects which determine the operation of the Signal Converter. The quantity of entries in this table is defined by modemNumber." ::= { hdmSc 1 } hdmScEntry OBJECT-TYPE SYNTAX HdmScEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Objects that define the operation of the modem's Signal Converter." INDEX { hdmScIndex, hdmScIndex2 } ::= { hdmScTable 1 } HdmScEntry ::= SEQUENCE { hdmScIndex INTEGER, hdmScIndex2 INTEGER, hdmScLinkRateMin INTEGER, hdmScLinkRateMax INTEGER, hdmScNonArqBufSize INTEGER, hdmScNonMnpDataCapture INTEGER, hdmScV21Mod INTEGER, hdmScV32UnencodedMod INTEGER, hdmScV32Mod INTEGER, hdmScV32Bis INTEGER, hdmScV32BisEnhance INTEGER, hdmScV32QuickRetrain INTEGER, hdmScV23 INTEGER, hdmScFallback INTEGER, hdmScV32TerboModeEnable INTEGER, hdmScV34ModeEnable INTEGER, hdmScVFCSymRate2400 INTEGER, hdmScVFCSymRate2743 INTEGER, hdmScVFCSymRate2800 INTEGER, hdmScVFCSymRate3000 INTEGER, hdmScVFCSymRate3200 INTEGER, hdmScVFCSymRate3429 INTEGER, hdmScVFC8S2DMapping INTEGER, hdmScVFC16S4DMapping INTEGER, hdmScVFC32S2DMapping INTEGER, hdmScVFC64S4DMapping INTEGER, hdmScVFCNonLinearCoding INTEGER, hdmScVFCTxLevelDeviation INTEGER, hdmScVFCPreEmphasis INTEGER, hdmScVFCPreCoding INTEGER, hdmScVFCShaping INTEGER, hdmScVFCModeEnable INTEGER, hdmScV8 INTEGER, hdmSCV8CallIndicator INTEGER, hdmScV34pModeEnable INTEGER, hdmScX2LowerSpeedMin INTEGER, hdmScX2LowerSpeedMax INTEGER, hdmScX2DisableClient INTEGER, hdmScX2DisableServer INTEGER, hdmScX2DIsableSymmetric INTEGER, hdmSc300 INTEGER, hdmSc1200 INTEGER, hdmSc2400 INTEGER, hdmScHighSpeed INTEGER, hdmScSelectiveReject INTEGER, hdmScHighPowerConst INTEGER, hdmScV90Analogue INTEGER, hdmScV90Digital INTEGER, hdmScV90AllDigital INTEGER } hdmScIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The unique value found in the chassis mib entity relation table that references this modem." ::= { hdmScEntry 1 } hdmScIndex2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The Secondary unique value found in the chassis mib entity relation table that references this modem." ::= { hdmScEntry 2 } hdmScLinkRateMin OBJECT-TYPE SYNTAX INTEGER{ variable(1), bps300(2), bps1200(3), bps2400(4), bps4800(5), bps7200(6), bps9600(7), bps12000(8), bps14400(9), bps16800(10), bps19200(11), bps21600(12), bps24000(13), bps26400(14), bps28800(15), bps31200(16), bps33600(17), bps33333(18), bps37333(19), bps41333(20), bps42666(21), bps44000(22), bps45333(23), bps46666(24), bps48000(25), bps49333(26), bps50666(27), bps52000(28), bps53333(29), bps54666(30), bps56000(31), bps57333(32), bps64000(33), bps28000(34), bps29333(35), bps30666(36), bps32000(37), bps34666(38), bps36000(39), bps38666(40), bps40000(41), bps58666(42), bps60000(43), bps61333(44), bps62666(45) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the Minimum link rate" ::= { hdmScEntry 3 } hdmScLinkRateMax OBJECT-TYPE SYNTAX INTEGER{ variable(1), bps300(2), bps1200(3), bps2400(4), bps4800(5), bps7200(6), bps9600(7), bps12000(8), bps14400(9), bps16800(10), bps19200(11), bps21600(12), bps24000(13), bps26400(14), bps28800(15), bps31200(16), bps33600(17), bps33333(18), bps37333(19), bps41333(20), bps42666(21), bps44000(22), bps45333(23), bps46666(24), bps48000(25), bps49333(26), bps50666(27), bps52000(28), bps53333(29), bps54666(30), bps56000(31), bps57333(32), bps64000(33), bps28000(34), bps29333(35), bps30666(36), bps32000(37), bps34666(38), bps36000(39), bps38666(40), bps40000(41), bps58666(42), bps60000(43), bps61333(44), bps62666(45) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the Maximum link Rate" ::= { hdmScEntry 4 } hdmScNonArqBufSize OBJECT-TYPE SYNTAX INTEGER{ bytes1500(1), bytes128(2) } ACCESS read-write STATUS mandatory DESCRIPTION " Sets the sizer of the transmit buffer for non-ARQ mode operation to either 128 bytes or 1.5K. The smaller size is for low speed interactive applications, the large size is for file transfer. Default=128." ::= { hdmScEntry 5 } hdmScNonMnpDataCapture OBJECT-TYPE SYNTAX INTEGER{ disable(1), enable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Causes received characters to be buffered when the modem is attempting to negotiate an MNP call and the remote modem is not. Default=disabled." ::= { hdmScEntry 6 } hdmScV21Mod OBJECT-TYPE SYNTAX INTEGER{ disable(1), enable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When enabled, the modem will answer both bell 103 and V.21 calls but originates only V.21 calls. Default=disabled." ::= { hdmScEntry 7 } hdmScV32UnencodedMod OBJECT-TYPE SYNTAX INTEGER{ disable(1), enable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Allows unencoded modulation in V.32 mode. Although part of the CCITT V.32 recomendation it is rarely used. Default=disabled." ::= { hdmScEntry 8 } hdmScV32Mod OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Allows V.32 modulation to be disabled on USRobotics Dual Standard modems. Default=enabled." ::= { hdmScEntry 9 } hdmScV32Bis OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Allows V.32 bis modulation to be disabled. On USRobotics Dual Standard modems this may be useful in troublshooting HST operation. Default=V.32 bis enabled." ::= { hdmScEntry 10 } hdmScV32BisEnhance OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Allows USRobotics V.32 Enahnced mode to be disabled for purposes of troubleshooting Default=enabled." ::= { hdmScEntry 11 } hdmScV32QuickRetrain OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Allows the faster retrains that occur with USR's enhanced V.32 mode to be disabled for troubleshooting purposes. Default=enabled." ::= { hdmScEntry 12 } hdmScV23 OBJECT-TYPE SYNTAX INTEGER{ disable(1), enable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Allows the modem to negotiate a V.23 connection(used in U.K.) after failing to negotiate a higher rate. Default=disabled." ::= { hdmScEntry 13 } hdmScFallback OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Defines whether or not the modem will be allowed to change protocols it detects a significant change in the line characteristics. If the modem is unable to maintain transmission with the current modulation technique it would fall back to a lower speed and if the line then improved it would upshift to a higher speed. Default=enabled." ::= { hdmScEntry 14 } hdmScV32TerboModeEnable OBJECT-TYPE SYNTAX INTEGER{ disable(1), enable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Allows the V32 Terbo mode to be disabled/enabled." ::= { hdmScEntry 15 } hdmScV34ModeEnable OBJECT-TYPE SYNTAX INTEGER{ disable(1), enable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Allows V34 mode to be disabled/enabled." ::= { hdmScEntry 16 } hdmScVFCSymRate2400 OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Allows the 2400 symbol rate to be disabled/enabled on V.FC modems." ::= { hdmScEntry 17 } hdmScVFCSymRate2743 OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Allows the 2743 symbol rate to be disabled/enabled on V.FC modems." ::= { hdmScEntry 18 } hdmScVFCSymRate2800 OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Allows the 2800 symbol rate to be disabled/enabled on V.FC modems." ::= { hdmScEntry 19 } hdmScVFCSymRate3000 OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Allows the 3000 symbol rate to be disabled/enabled on V.FC modems." ::= { hdmScEntry 20 } hdmScVFCSymRate3200 OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Allows the 3200 symbol rate to be disabled/enabled on V.FC modems." ::= { hdmScEntry 21 } hdmScVFCSymRate3429 OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Allows the 3429 symbol rate to be disabled/enabled on V.FC modems." ::= { hdmScEntry 22 } hdmScVFC8S2DMapping OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Allows the 8S-2D mapping to be disabled/enabled on V.FC modems." ::= { hdmScEntry 23 } hdmScVFC16S4DMapping OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Allows the 16S-4D mapping to be disabled/enabled on V.FC modems." ::= { hdmScEntry 24 } hdmScVFC32S2DMapping OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Allows the 32S-2D mapping to be disabled/enabled on V.FC modems." ::= { hdmScEntry 25 } hdmScVFC64S4DMapping OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Allows the 64S-4D mapping to be disabled/enabled on V.FC modems." ::= { hdmScEntry 26 } hdmScVFCNonLinearCoding OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Allows the non-linear coding to be disabled/enabled on V.FC modems." ::= { hdmScEntry 27 } hdmScVFCTxLevelDeviation OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Allows the TX level deviation to be disabled/enabled on V.FC modems." ::= { hdmScEntry 28 } hdmScVFCPreEmphasis OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Allows the pre-emphasis to be disabled/enabled on V.FC modems." ::= { hdmScEntry 29 } hdmScVFCPreCoding OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Allows the precoding to be disabled/enabled on V.FC modems." ::= { hdmScEntry 30 } hdmScVFCShaping OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Allows the shaping to be disabled/enabled on V.FC modems." ::= { hdmScEntry 31 } hdmScVFCModeEnable OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Allows to disable/enable V.FC mode in order to troubleshoot a connection." ::= { hdmScEntry 32 } hdmScV8 OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Allow V8 mode to be disabled/enabled" ::= { hdmScEntry 33 } hdmSCV8CallIndicator OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Allow V.8. call indicater to be disabled/enabled." ::= { hdmScEntry 34 } hdmScV34pModeEnable OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Allows V34 plus modulation mode to be disabled. (default=0/enabled)" ::= { hdmScEntry 35 } hdmScX2LowerSpeedMin OBJECT-TYPE SYNTAX INTEGER{ variable(1), bps300(2), bps1200(3), bps2400(4), bps4800(5), bps7200(6), bps9600(7), bps12000(8), bps14400(9), bps16800(10), bps19200(11), bps21600(12), bps24000(13), bps26400(14), bps28800(15), bps31200(16), bps33600(17), bps33333(18), bps37333(19), bps41333(20), bps42666(21), bps44000(22), bps45333(23), bps46666(24), bps48000(25), bps49333(26), bps50666(27), bps52000(28), bps53333(29), bps54666(30), bps56000(31), bps57333(32), bps64000(33), bps28000(34), bps29333(35), bps30666(36), bps32000(37), bps34666(38), bps36000(39), bps38666(40), bps40000(41), bps58666(42), bps60000(43), bps61333(44), bps62666(45) } ACCESS read-write STATUS mandatory DESCRIPTION "Lower speed direction minimum speed Default=0" ::= { hdmScEntry 36 } hdmScX2LowerSpeedMax OBJECT-TYPE SYNTAX INTEGER{ variable(1), bps300(2), bps1200(3), bps2400(4), bps4800(5), bps7200(6), bps9600(7), bps12000(8), bps14400(9), bps16800(10), bps19200(11), bps21600(12), bps24000(13), bps26400(14), bps28800(15), bps31200(16), bps33600(17), bps33333(18), bps37333(19), bps41333(20), bps42666(21), bps44000(22), bps45333(23), bps46666(24), bps48000(25), bps49333(26), bps50666(27), bps52000(28), bps53333(29), bps54666(30), bps56000(31), bps57333(32), bps64000(33), bps28000(34), bps29333(35), bps30666(36), bps32000(37), bps34666(38), bps36000(39), bps38666(40), bps40000(41), bps58666(42), bps60000(43), bps61333(44), bps62666(45) } ACCESS read-write STATUS mandatory DESCRIPTION "Lower speed direction maximum speed Default=0" ::= { hdmScEntry 37 } hdmScX2DisableClient OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "X2 Client Mode Disable Default=enable." ::= { hdmScEntry 38 } hdmScX2DisableServer OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "X2 Server Mode Disable Default=enable." ::= { hdmScEntry 39 } hdmScX2DIsableSymmetric OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "X2 Symmetric Mode Disable Default=enable." ::= { hdmScEntry 40 } hdmSc300 OBJECT-TYPE SYNTAX INTEGER{ disable(1), enable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Restrict 300 baud negotiations. Register S48.0 Default is disable (0) restriction." ::= { hdmScEntry 53 } hdmSc1200 OBJECT-TYPE SYNTAX INTEGER{ disable(1), enable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Restrict 1200 baud negotiations. Register S48.1 Default is disable (0) restriction." ::= { hdmScEntry 54 } hdmSc2400 OBJECT-TYPE SYNTAX INTEGER{ disable(1), enable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Restrict 2400 baud negotiations. Register S48.2 Default is disable (0) restriction." ::= { hdmScEntry 55 } hdmScHighSpeed OBJECT-TYPE SYNTAX INTEGER{ disable(1), enable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Restrict highspeed baud negotiations. Register S48.3 Default is disable (0) restriction." ::= { hdmScEntry 56 } hdmScSelectiveReject OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Selective Reject register S51.6 is a function of the V.42/LAPM protocol. The default is enable (1)" ::= { hdmScEntry 57 } hdmScHighPowerConst OBJECT-TYPE SYNTAX INTEGER{ disable(1), enable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to enable/disable the X2 high-power constellation. This object is only valid in countries, where it is legal. It corresponds to S Register 76.7 Default = Disable(1)." ::= { hdmScEntry 58 } hdmScV90Analogue OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to enable/disable the V.90 client (APCM) modulation. Default= enable(1)." ::= { hdmScEntry 59 } hdmScV90Digital OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to enable/disable the V.90 server modulation (DPCM). Default= enable(1)." ::= { hdmScEntry 60 } hdmScV90AllDigital OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to enable/disable the V.90 symmetric modulation (DDPCM). Default= enable(1)." ::= { hdmScEntry 61 } -- The modem Call Control group hdmCc OBJECT IDENTIFIER ::= { hdm 4 } hdmCcTable OBJECT-TYPE SYNTAX SEQUENCE OF HdmCcEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing the call control parameters for each modem in the chassis." ::= { hdmCc 1 } hdmCcEntry OBJECT-TYPE SYNTAX HdmCcEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Call control parameters for a modem. These define the sequence of operation related to how a call is negotiated." INDEX { hdmCcIndex, hdmCcIndex2 } ::= { hdmCcTable 1 } HdmCcEntry ::= SEQUENCE { hdmCcIndex INTEGER, hdmCcIndex2 INTEGER, hdmCcDialDelay INTEGER, hdmCcWaitForCarrier INTEGER, hdmCcInactivityTimer INTEGER, hdmCcQuietResultCodes INTEGER, hdmCcResponseMode INTEGER, hdmCcResultCodeOptions INTEGER, hdmCcArqResultCodeMode INTEGER, hdmCcEscCodeRsp INTEGER, hdmCcAtRecognition INTEGER, hdmCcV32ToneDuration INTEGER, hdmCcAutoAnswer INTEGER, hdmCcAnswerInOrigMode INTEGER, hdmCcPhoneString0 DisplayString, hdmCcPhoneString1 DisplayString, hdmCcPhoneString2 DisplayString, hdmCcPhoneString3 DisplayString, hdmCcErrorCntlMode INTEGER, hdmCcMnpWith1200 INTEGER, hdmCcMnpWith2400 INTEGER, hdmCcMnpWithV32 INTEGER, hdmCcMnpTimeout INTEGER, hdmCcV21V23FallBackTimer INTEGER, hdmCcAddnlAnswToneDur INTEGER, hdmCcBillingDelayPeriod INTEGER, hdmCcCarrierAccessCode1 DisplayString, hdmCcCarrierAccessCode2 DisplayString, hdmCcCarrierAccessCode3 DisplayString, hdmCcCallingInitStr1 DisplayString, hdmCcCallingInitStr2 DisplayString, hdmCcCallingInitStr3 DisplayString, hdmCcCallingInitStr4 DisplayString, hdmCcT1CallSetupProc INTEGER, hdmCcT1KpStMfTones INTEGER, hdmCcT1CallInitStrUse INTEGER, hdmCcT1CallInitStrBase INTEGER, hdmCcT1DialInAniDig INTEGER, hdmCcT1DialInDnisDig INTEGER } hdmCcIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index which uniquely identifies the modem to which this entry is applicable. The value corresponds to the value of the index to the entity table in the chassis MIB that corresponds to the same modem." ::= { hdmCcEntry 1 } hdmCcIndex2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The Secondary index which uniquely identifies the modem to which this entry is applicable. The value corresponds to the value of the index to the entity table in the chassis MIB that corresponds to the same modem." ::= { hdmCcEntry 2 } hdmCcDialDelay OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Defines the number of seconds the modem waits between going off hook and begining to dial. Ignored when result code options 2,4,6,or 7 are active. Default=2." ::= { hdmCcEntry 3 } hdmCcWaitForCarrier OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Defines the number of seconds the modem will wait for a carrier signal after dialing. Default=60." ::= { hdmCcEntry 4 } hdmCcInactivityTimer OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Sets the duration (in seconds) that the modem will maintain a connection when there is no activity on the phone line. The feature is disabled when set to 0. Default=0." ::= { hdmCcEntry 5 } hdmCcQuietResultCodes OBJECT-TYPE SYNTAX INTEGER{ displayResult(1), noResult(2), originateOnly(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines whether or not the modem transmits result codes to the DTE. Default=noResult(2)." ::= { hdmCcEntry 6 } hdmCcResponseMode OBJECT-TYPE SYNTAX INTEGER{ numeric(1), verbal(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines whether the modem transmits result codes in the verbal or numeric mode. Default=verbal(2)." ::= { hdmCcEntry 7 } hdmCcResultCodeOptions OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-write STATUS mandatory DESCRIPTION "Defines one of eight result code subsets and also defines indirectly how the modem reacts to dial tone etc. Equates to the modem's X register Default=1." ::= { hdmCcEntry 8 } hdmCcArqResultCodeMode OBJECT-TYPE SYNTAX INTEGER{ arqResultsDisabled(1), arqResultsEnabled(2), includeHstV32(3), includeProtocol(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Defines whether or not the ARQ result codes are sent to the DTE on connection(if result codes are enabled). Default=arqResultsEnabled(2)." ::= { hdmCcEntry 9 } hdmCcEscCodeRsp OBJECT-TYPE SYNTAX INTEGER{ goOnHook(1), enterCommandMode(2), ignoreEscCode(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Defines the action of the modem in response to the escape code(+++). The default value is determined by the state of Dip switch 2-3 on power up." ::= { hdmCcEntry 10 } hdmCcAtRecognition OBJECT-TYPE SYNTAX INTEGER{ ignore(1), queryOnly(2), enableAll(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines which, if any, AT commands the modem will recognize or accept from the DTE. Default=enableAll(3)." ::= { hdmCcEntry 11 } hdmCcV32ToneDuration OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the duration (in 10ths of a second) that the modem transmits the 3000/600 Hz answer tones for V.32 handshaking. A setting of 0 eliminates these tones and will result in faster connect times for V.21 and V.23 calls. Default=8." ::= { hdmCcEntry 12 } hdmCcAutoAnswer OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Determines the number of rings that the modem will answer calls on. When set to 0 the modem can only originate calls. Default=1." ::= { hdmCcEntry 14 } hdmCcAnswerInOrigMode OBJECT-TYPE SYNTAX INTEGER{ disable(1), enable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When enabled the modem will answer calls using the sequence normaly used by the originating modem. Default=disable(1)." ::= { hdmCcEntry 15 } hdmCcPhoneString0 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..36)) ACCESS read-write STATUS mandatory DESCRIPTION "Phone number stored in modem's non volitile memory. Useful in providing quick access to frequently called numbers. In addition mdmCcPhoneString0 is used for the dial on power up and dial on DTR options." ::= { hdmCcEntry 16 } hdmCcPhoneString1 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..36)) ACCESS read-write STATUS mandatory DESCRIPTION "Phone number stored in the modem's non volitile memory, useful for providing quick access to frequently called numbers." ::= { hdmCcEntry 17 } hdmCcPhoneString2 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..36)) ACCESS read-write STATUS mandatory DESCRIPTION "Phone number stored in the modem's non volitile memory, useful in providing quick access to frequently called numbers." ::= { hdmCcEntry 18 } hdmCcPhoneString3 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..36)) ACCESS read-write STATUS mandatory DESCRIPTION "Phone number stored in the modem's non volitile memory, useful in providing quick access to frequently called numbers." ::= { hdmCcEntry 19 } hdmCcErrorCntlMode OBJECT-TYPE SYNTAX INTEGER{ none(1), syncMode(2), normalArq(3), arqOnly(4), v25bisChar(5), v25bisBit(6) } ACCESS read-write STATUS mandatory DESCRIPTION "Defines if the modem is operating in synchronous or asynchronous mode and how it responds relative to negotiation of error control on asynchronous connections. When set to the default, normalArq(3), the modem attempts to connect with error control but if unable to negotiate it connects anyway. When set to none(1), async connections do not attempt to use error control. When set to arqOnly(4), the modem will hang up if unable to negotiate error contol. When set to syncMode(2), the modem will not connect asynchronously." ::= { hdmCcEntry 20 } hdmCcMnpWith1200 OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines if the modem will include MNP/V42 negotiation on 1200 bps connections. Default=enable(1)." ::= { hdmCcEntry 21 } hdmCcMnpWith2400 OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines if the modem will include MNP/V43 negotiation on 2400 bps calls. default=enable(1)." ::= { hdmCcEntry 22 } hdmCcMnpWithV32 OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines if the modem will include MNP/V42 negotiation on V.32 connections. Default=enable(1)." ::= { hdmCcEntry 23 } hdmCcMnpTimeout OBJECT-TYPE SYNTAX INTEGER (0..14) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the MNP/V42 link request timeout for negotiation of 1200 and 2400 bps calls. Default=5." ::= { hdmCcEntry 24 } hdmCcV21V23FallBackTimer OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "V21/V23 fallback timer, 1/10 sec. NVRAM S Register S29. Default=20" ::= { hdmCcEntry 25 } hdmCcAddnlAnswToneDur OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Additional answer tone duration, 1/10 sec. NVRAM S Register S49. Default=16." ::= { hdmCcEntry 26 } hdmCcBillingDelayPeriod OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Billing Delay Period. 1/50 sec. NVRAM S Register S50. Default=100." ::= { hdmCcEntry 27 } hdmCcCarrierAccessCode1 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..10)) ACCESS read-write STATUS optional DESCRIPTION "The DNIS Carrier Access Code (CAC) Number. This is a string which contains a number from 1 to 10 digits (e.g. 9501755). This is the 1st of 3 CACs." ::= { hdmCcEntry 28 } hdmCcCarrierAccessCode2 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..10)) ACCESS read-write STATUS optional DESCRIPTION "The DNIS Carrier Access Code (CAC) Number. This is a string which contains a number from 1 to 10 digits. This is the 2nd of 3 CACs." ::= { hdmCcEntry 29 } hdmCcCarrierAccessCode3 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..10)) ACCESS read-write STATUS optional DESCRIPTION "The DNIS Carrier Access Code (CAC) Number. This is a string which contains a number from 1 to 10 digits. This is the 3rd of 3 CACs." ::= { hdmCcEntry 30 } hdmCcCallingInitStr1 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..40)) ACCESS read-write STATUS optional DESCRIPTION "This is the Carrier Access Code (CAC) initialization string. This string is a configuration string of 1 to 30 characters (e.g. &F, &F&B1&R1, etc.) This string does NOT include the AT attention prefix. This is the 1st of 4 CAC init strings." ::= { hdmCcEntry 31 } hdmCcCallingInitStr2 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..40)) ACCESS read-write STATUS optional DESCRIPTION "This is the Carrier Access Code (CAC) initialization string. This string is 1 to 30 characters. It does NOT include the AT attention prefix. It is the 2nd of 4 CAC init strings." ::= { hdmCcEntry 32 } hdmCcCallingInitStr3 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..40)) ACCESS read-write STATUS optional DESCRIPTION "This is the Carrier Access Code (CAC) initialization string. This is a string of 1 to 30 characters. It does NOT include the AT attention prefix. This is the 3rd of 4 CAC init strings." ::= { hdmCcEntry 33 } hdmCcCallingInitStr4 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..40)) ACCESS read-write STATUS optional DESCRIPTION "This is the Carrier Access Code (CAC) initialization string. This is a string of 1 to 30 characters. It does NOT include the AT attention prefix. This is the 4th of 4 CAC init strings." ::= { hdmCcEntry 34 } hdmCcT1CallSetupProc OBJECT-TYPE SYNTAX INTEGER{ normalSetup(1), noSetup(2) } ACCESS read-write STATUS optional DESCRIPTION "Determines T1 call setup procedures used. Choices are 'normal' or 'none'. None assumes a dedicated (leased) DS0 assigned to the modem. Default=normalSetup(1)." ::= { hdmCcEntry 35 } hdmCcT1KpStMfTones OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-write STATUS optional DESCRIPTION "Determines the usage of KP and ST MF tone encapsulation of the dial sequence. Default=enable(1)." ::= { hdmCcEntry 36 } hdmCcT1CallInitStrUse OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-write STATUS optional DESCRIPTION "Determines if calling init strings are used or not. Default=enable(1)." ::= { hdmCcEntry 37 } hdmCcT1CallInitStrBase OBJECT-TYPE SYNTAX INTEGER{ dnisBase(1), aniBase(2) } ACCESS read-write STATUS optional DESCRIPTION "Determines if the calling init strings are based upon DNIS or ANI. Default=dnisBase(1)." ::= { hdmCcEntry 38 } hdmCcT1DialInAniDig OBJECT-TYPE SYNTAX INTEGER (0..12) ACCESS read-write STATUS optional DESCRIPTION "Sets the number of ANI digits allowed in incoming calls. Default = 0." ::= { hdmCcEntry 39 } hdmCcT1DialInDnisDig OBJECT-TYPE SYNTAX INTEGER (0..12) ACCESS read-write STATUS optional DESCRIPTION "Sets the number of DNIS/DID digits allowed in incoming calls. Default = 0." ::= { hdmCcEntry 40 } -- The modem Error Correction group hdmEc OBJECT IDENTIFIER ::= { hdm 5 } hdmEcTable OBJECT-TYPE SYNTAX SEQUENCE OF HdmEcEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of Error Control Parameters for each modem in this system, the quantity of entries is given by modemNumber." ::= { hdmEc 1 } hdmEcEntry OBJECT-TYPE SYNTAX HdmEcEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Configurable objects which define the modems error control operation." INDEX { hdmEcIndex, hdmEcIndex2 } ::= { hdmEcTable 1 } HdmEcEntry ::= SEQUENCE { hdmEcIndex INTEGER, hdmEcIndex2 INTEGER, hdmEcMnp3Dis INTEGER, hdmEcMnp4Dis INTEGER, hdmEcMnpUnusual INTEGER, hdmEcV42MnpHandshake INTEGER } hdmEcIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object contains the unique value assigned to this modem in the chassis mib entity relation table and is used as the mechanism for correctly indexing into this table." ::= { hdmEcEntry 1 } hdmEcIndex2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This Secondary object contains the unique value assigned to this modem in the chassis mib entity relation table and is used as the mechanism for correctly indexing into this table." ::= { hdmEcEntry 2 } hdmEcMnp3Dis OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines if the modem will negotiate for MNP level 3 error correction. Default=enable." ::= { hdmEcEntry 3 } hdmEcMnp4Dis OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines if the modem will negotiate for MNP level 4 error correction. Default=enable." ::= { hdmEcEntry 4 } hdmEcMnpUnusual OBJECT-TYPE SYNTAX INTEGER{ disable(1), enable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines if the modem will attempt to negotiate for MNP operation used in some early 2400bps modems. Default=disable." ::= { hdmEcEntry 5 } hdmEcV42MnpHandshake OBJECT-TYPE SYNTAX INTEGER{ enableAll(1), enableV42disableMnp(2), disablev42enablemnp(3), disableDetectionPhase(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines what types of error correction the modem will attempt to negotiate. When configured for the default, full V.42 and MNP, the modem first tries to connect with V42 error control and then with MNP error control. When set to disable either V42 or MNP the modem will only attempt to negotiate the enabled protocol. When set to disable the V42 detect phase, it is not included in the handshaking process. This allows for faster connections between V42 modems." ::= { hdmEcEntry 6 } -- The modem Event Threshold group hdmEt OBJECT IDENTIFIER ::= { hdm 6 } hdmEtTable OBJECT-TYPE SYNTAX SEQUENCE OF HdmEtEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of event thresholds used for setting up the modem to report events that can in turn be monitored by RMON." ::= { hdmEt 1 } hdmEtEntry OBJECT-TYPE SYNTAX HdmEtEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Event Thresholds that are used by the modem and the NMC to qualify certain events." INDEX { hdmEtIndex, hdmEtIndex2 } ::= { hdmEtTable 1 } HdmEtEntry ::= SEQUENCE { hdmEtIndex INTEGER, hdmEtIndex2 INTEGER, hdmEtDteIdleThresh INTEGER, hdmEtConnTimeLimit INTEGER, hdmEtBlerThresh INTEGER, hdmEtFallbackThresh INTEGER } hdmEtIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Index into table used to identify the the specific modem, contians the unique value from the chassis mib entity table." ::= { hdmEtEntry 1 } hdmEtIndex2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Secondary Index into table used to identify the the specific modem, contians the unique value from the chassis mib entity table." ::= { hdmEtEntry 2 } hdmEtDteIdleThresh OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Defines the length of time for the modem to wait before reporting a 'DTE transmit data idle' event. (There must be no activity on the DTE transmit line for the specified quantity of minutes." ::= { hdmEtEntry 3 } hdmEtConnTimeLimit OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Defines the number of minutes that a call may be connected before triggering the 'connect timer limit' event. A value of zero for this limit means that no event is to be detected (ie. no time limit)." ::= { hdmEtEntry 4 } hdmEtBlerThresh OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Defines the number of BLERs that will be used to qualify the 'BLER count at threshold' event for a given call." ::= { hdmEtEntry 5 } hdmEtFallbackThresh OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Defines the number of fallbacks at which the 'fallback count at threshold' event will be generated for a given call." ::= { hdmEtEntry 6 } hdmTe OBJECT IDENTIFIER ::= { hdm 7 } hdmTeTable OBJECT-TYPE SYNTAX SEQUENCE OF HdmTeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing an enable for each trap that a modem entity is capable of generating. Some of these events occur often and traps may flood the network if care is not taken to avoid such conditions. These traps should be enabled sparingly. (usually only when debugging a problem on a particular modem)" ::= { hdmTe 1 } hdmTeEntry OBJECT-TYPE SYNTAX HdmTeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "There is one modem trap enable row for each modem entity in the NAS chassis." INDEX { hdmTeIndex, hdmTeIndex2 } ::= { hdmTeTable 1 } HdmTeEntry ::= SEQUENCE { hdmTeIndex INTEGER, hdmTeIndex2 INTEGER, hdmTeInConnEstablished INTEGER, hdmTeOutConnEstablished INTEGER, hdmTeInConnTerminated INTEGER, hdmTeOutConnTerminated INTEGER, hdmTeConnLimitExpired INTEGER, hdmTeDteXmitDataIdle INTEGER, hdmTeBlerCountAtThresh INTEGER, hdmTeFallbkCountAtThresh INTEGER, hdmTePbActive INTEGER, hdmTePbLost INTEGER, hdmTeDteRingNoAns INTEGER, hdmTeInConnAttemptFail INTEGER, hdmTeOutConnAttemptFail INTEGER, hdmTePBClockLost INTEGER, hdmTePBClockRestored INTEGER } hdmTeIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique index which identifies the modem for which these trap enables pertain. The index to the trap enable table matches the index of the corresponding modem in the entity table in the chassis MIB." ::= { hdmTeEntry 1 } hdmTeIndex2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A Secondary unique index which identifies the modem for which these trap enables pertain. The index to the trap enable table matches the index of the corresponding modem in the entity table in the chassis MIB." ::= { hdmTeEntry 2 } hdmTeInConnEstablished OBJECT-TYPE SYNTAX INTEGER{ enableTrap(1), disableAll(2), enableLog(3), enableAll(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Enables generation of an SNMP trap upon detection of an incoming connection establishment on the specified modem." ::= { hdmTeEntry 3 } hdmTeOutConnEstablished OBJECT-TYPE SYNTAX INTEGER{ enableTrap(1), disableAll(2), enableLog(3), enableAll(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Enables generation of an SNMP trap upon detection of an outgoing connection establishment on the specified modem." ::= { hdmTeEntry 4 } hdmTeInConnTerminated OBJECT-TYPE SYNTAX INTEGER{ enableTrap(1), disableAll(2), enableLog(3), enableAll(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Enables generation of an SNMP trap upon detection of an incoming connection termination on the specified modem." ::= { hdmTeEntry 5 } hdmTeOutConnTerminated OBJECT-TYPE SYNTAX INTEGER{ enableTrap(1), disableAll(2), enableLog(3), enableAll(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Enables generation of an SNMP trap upon detection of an outgoing connection terminated on the specified modem." ::= { hdmTeEntry 6 } hdmTeConnLimitExpired OBJECT-TYPE SYNTAX INTEGER{ enableTrap(1), disableAll(2), enableLog(3), enableAll(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Enables generation of an SNMP trap upon detection of the expiration of the connection time limit on the specified modem." ::= { hdmTeEntry 7 } hdmTeDteXmitDataIdle OBJECT-TYPE SYNTAX INTEGER{ enableTrap(1), disableAll(2), enableLog(3), enableAll(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Enables generation of an SNMP trap upon detection of DTE transmit data idle on the specified modem." ::= { hdmTeEntry 8 } hdmTeBlerCountAtThresh OBJECT-TYPE SYNTAX INTEGER{ enableTrap(1), disableAll(2), enableLog(3), enableAll(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Enables generation of an SNMP trap upon detection of the BLER count at the specified threshold on the specified modem." ::= { hdmTeEntry 9 } hdmTeFallbkCountAtThresh OBJECT-TYPE SYNTAX INTEGER{ enableTrap(1), disableAll(2), enableLog(3), enableAll(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Enables generation of an SNMP trap upon detection of the fallback count at the specified threshold on the specified modem." ::= { hdmTeEntry 10 } hdmTePbActive OBJECT-TYPE SYNTAX INTEGER{ enableTrap(1), disableAll(2), enableLog(3), enableAll(4) } ACCESS read-write STATUS optional DESCRIPTION "Enables the Packet Bus Active. Default = disable(2)." ::= { hdmTeEntry 11 } hdmTePbLost OBJECT-TYPE SYNTAX INTEGER{ enableTrap(1), disableAll(2), enableLog(3), enableAll(4) } ACCESS read-write STATUS optional DESCRIPTION "Enables the Packet Bus Lost trap. Default = disable(2)." ::= { hdmTeEntry 12 } hdmTeDteRingNoAns OBJECT-TYPE SYNTAX INTEGER{ enableTrap(1), disableAll(2), enableLog(3), enableAll(4) } ACCESS read-write STATUS optional DESCRIPTION "Enables the Dte Ring No Answer trap. Default = disable(2)." ::= { hdmTeEntry 13 } hdmTeInConnAttemptFail OBJECT-TYPE SYNTAX INTEGER{ enableTrap(1), disableAll(2), enableLog(3), enableAll(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Enables generation of an SNMP trap upon detection of an in bound connection attemp failure on the specified modem." ::= { hdmTeEntry 14 } hdmTeOutConnAttemptFail OBJECT-TYPE SYNTAX INTEGER{ enableTrap(1), disableAll(2), enableLog(3), enableAll(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Enables generation of an SNMP trap upon detection of an out bound connection attemp failure on the specified modem." ::= { hdmTeEntry 15 } hdmTePBClockLost OBJECT-TYPE SYNTAX INTEGER{ enableTrap(1), disableAll(2), enableLog(3), enableAll(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Enables generation of an SNMP trap upon detection of packet bus clock lost" ::= { hdmTeEntry 16 } hdmTePBClockRestored OBJECT-TYPE SYNTAX INTEGER{ enableTrap(1), disableAll(2), enableLog(3), enableAll(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Enables generation of an SNMP trap upon detection of packet bus clock Restored" ::= { hdmTeEntry 17 } hdmAutoResponse OBJECT IDENTIFIER ::= { hdm 8 } hdmArTable OBJECT-TYPE SYNTAX SEQUENCE OF HdmArEntry ACCESS not-accessible STATUS optional DESCRIPTION "Table of auto response scripts for each modem in the chassis. The number of table entries is specified by modemNumber." ::= { hdmAutoResponse 1 } hdmArEntry OBJECT-TYPE SYNTAX HdmArEntry ACCESS not-accessible STATUS optional DESCRIPTION "List of configurable auto response scripts." INDEX { hdmArIndex, hdmArIndex2 } ::= { hdmArTable 1 } HdmArEntry ::= SEQUENCE { hdmArIndex INTEGER, hdmArIndex2 INTEGER, hdmArIncomConnectEstab OCTET STRING, hdmArOutgoConnectEstab OCTET STRING, hdmArIncomConnectTerm OCTET STRING, hdmArOutgoConnectTerm OCTET STRING, hdmArConnectAttemptFail OCTET STRING, hdmArConnectTimeExpire OCTET STRING, hdmArDteXmitIdle OCTET STRING, hdmArBlersAtThresh OCTET STRING, hdmArFbacksAtThresh OCTET STRING, hdmArWatchdog OCTET STRING, hdmArMgtBusFailure OCTET STRING, hdmArMdmRingNoAnswer OCTET STRING, hdmArDteRingNoAnswer OCTET STRING, hdmArNoLoopCurrent OCTET STRING, hdmArTimer1 OCTET STRING, hdmArTimer2 OCTET STRING, hdmArTimer3 OCTET STRING, hdmArTimer4 OCTET STRING } hdmArIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Index in to the auto response table. This index contains the unique value associated with the modem as defined in the chassis mib entity table." ::= { hdmArEntry 1 } hdmArIndex2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Secondary Index in to the auto response table. This index contains the unique value associated with the modem as defined in the chassis mib entity table." ::= { hdmArEntry 2 } hdmArIncomConnectEstab OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..20)) ACCESS read-write STATUS optional DESCRIPTION "This script is triggered when a Total Control WAN HUB modem establishes a connection with a remote modem. The remote modem is the caller." ::= { hdmArEntry 3 } hdmArOutgoConnectEstab OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..20)) ACCESS read-write STATUS optional DESCRIPTION "This script is triggered when a Total Control WAN HUB modem establishes a connection with a remote modem. The Total Control WAN HUB modem is the caller." ::= { hdmArEntry 4 } hdmArIncomConnectTerm OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..20)) ACCESS read-write STATUS optional DESCRIPTION "This script is triggered after a remote modem has called a Total Control WAN HUB modem, but the connection between them terminated for some reason." ::= { hdmArEntry 5 } hdmArOutgoConnectTerm OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..20)) ACCESS read-write STATUS optional DESCRIPTION "This script is triggered after a Total Control WAN HUB modem called a remote modem, but the connection between them terminated for some reason." ::= { hdmArEntry 6 } hdmArConnectAttemptFail OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..20)) ACCESS read-write STATUS optional DESCRIPTION "This script is triggered when a Total Control WAN HUB modem fails to connect with a remote modem for an incoming or an outgoing call." ::= { hdmArEntry 7 } hdmArConnectTimeExpire OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..20)) ACCESS read-write STATUS optional DESCRIPTION "This script is triggered when a connection duration exceeds the user defined connection time limit." ::= { hdmArEntry 8 } hdmArDteXmitIdle OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..20)) ACCESS read-write STATUS optional DESCRIPTION "This script is triggered when a modem's DTE remains idle for specified amount of minutes that is defined by a user." ::= { hdmArEntry 9 } hdmArBlersAtThresh OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..20)) ACCESS read-write STATUS optional DESCRIPTION "This script is triggered when a Total Control WAN HUB modem receives a certain amount of block errors. This amount can be configured by a user." ::= { hdmArEntry 10 } hdmArFbacksAtThresh OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..20)) ACCESS read-write STATUS optional DESCRIPTION "This script is triggered when a Total Control WAN HUB modem reaches a certain amount of fall backs within a single session. This amount can be configured by a user." ::= { hdmArEntry 11 } hdmArWatchdog OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..20)) ACCESS read-write STATUS optional DESCRIPTION "This script is triggered when a software failure has occurred on a modem." ::= { hdmArEntry 12 } hdmArMgtBusFailure OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..20)) ACCESS read-write STATUS optional DESCRIPTION "This script is triggered when a contact with a modem, via the management bus, has been lost." ::= { hdmArEntry 13 } hdmArMdmRingNoAnswer OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..20)) ACCESS read-write STATUS optional DESCRIPTION "This script is triggered when a Total Control WAN HUB modem, configured for auto answer, fails to answer an incoming call within a specified number of rings. This amount is user configurable." ::= { hdmArEntry 14 } hdmArDteRingNoAnswer OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..20)) ACCESS read-write STATUS optional DESCRIPTION "This script is triggered when a DTE fials to raise DTR in response to an incoming call for a specified amount of rings. This amount is user configurable." ::= { hdmArEntry 15 } hdmArNoLoopCurrent OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..20)) ACCESS read-write STATUS optional DESCRIPTION "This script is triggered when a Total Control WAN HUB modem goes off hook, but it does not detect the presence of loop current on an analog phone line." ::= { hdmArEntry 16 } hdmArTimer1 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..20)) ACCESS read-write STATUS optional DESCRIPTION "This script is triggered when the first general purpose timer expires." ::= { hdmArEntry 17 } hdmArTimer2 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..20)) ACCESS read-write STATUS optional DESCRIPTION "This script is triggered when the second general purpose timer expires." ::= { hdmArEntry 18 } hdmArTimer3 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..20)) ACCESS read-write STATUS optional DESCRIPTION "This script is triggered when the third general purpose timer expires." ::= { hdmArEntry 19 } hdmArTimer4 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..20)) ACCESS read-write STATUS optional DESCRIPTION "This script is triggered when the fourth general purpose timer expires." ::= { hdmArEntry 20 } hdmDi OBJECT IDENTIFIER ::= { hdm 9 } hdmDiTable OBJECT-TYPE SYNTAX SEQUENCE OF HdmDiEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of configurable objects that define the operation of DTE interface in the modem." ::= { hdmDi 1 } hdmDiEntry OBJECT-TYPE SYNTAX HdmDiEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Objects that define the DTE interface for a modem." INDEX { hdmDiIndex, hdmDiIndex2 } ::= { hdmDiTable 1 } HdmDiEntry ::= SEQUENCE { hdmDiIndex INTEGER, hdmDiIndex2 INTEGER, hdmDiCarriageRetChar INTEGER, hdmDiLineFeedChar INTEGER, hdmDiBackspaceChar INTEGER, hdmDiCmdLocalEchoEna INTEGER, hdmDiBreakHandling INTEGER, hdmDiDteNvramLock INTEGER } hdmDiIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object contains the unique value assigned to this modem in the chassis mib entity relation table and is used as the mechanism for correctly indexing into this table." ::= { hdmDiEntry 1 } hdmDiIndex2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This Secondary object contains the unique value assigned to this modem in the chassis mib entity relation table and is used as the mechanism for correctly indexing into this table." ::= { hdmDiEntry 2 } hdmDiCarriageRetChar OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the decimal equivalent of the carriage return character. Default=13." ::= { hdmDiEntry 3 } hdmDiLineFeedChar OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the decimal equivalent of the line feed character. Default=10." ::= { hdmDiEntry 4 } hdmDiBackspaceChar OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the decimal equivalent of the backspace character. Default=8." ::= { hdmDiEntry 5 } hdmDiCmdLocalEchoEna OBJECT-TYPE SYNTAX INTEGER{ disable(1), enable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Defines whether or not the characters transmitted by the DTE are echoed back when in command mode. Default=disabled." ::= { hdmDiEntry 6 } hdmDiBreakHandling OBJECT-TYPE SYNTAX INTEGER{ destructiveNotSent(1), destructiveExpedited(2), nondestructiveExpedited(3), nondestructiveNotSent(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Defines the method used to handle received breaks. When defined as destructive the modem's transmit data buffer is flushed. When defined as expidited, the break preceeds any pending data in the transmit buffer. Default=Destructive,Expidited." ::= { hdmDiEntry 7 } hdmDiDteNvramLock OBJECT-TYPE SYNTAX INTEGER{ disable(1), enable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When locked, prohibits the DTE user from changing any of the NVRAM settings in the modem. Default=unlocked." ::= { hdmDiEntry 8 } -- The Modem ISDN Call Control group hdmICc OBJECT IDENTIFIER ::= { hdm 10 } hdmICcTable OBJECT-TYPE SYNTAX SEQUENCE OF HdmICcEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing the call control parameters for each modem in the chassis." ::= { hdmICc 1 } hdmICcEntry OBJECT-TYPE SYNTAX HdmICcEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Call control parameters for an ISDN modem. These define the sequence of operation related to how a call is negotiated." INDEX { hdmICcIndex, hdmICcIndex2 } ::= { hdmICcTable 1 } HdmICcEntry ::= SEQUENCE { hdmICcIndex INTEGER, hdmICcIndex2 INTEGER, hdmICcRateAdapV110 INTEGER, hdmICcFixedNtwkRate INTEGER, hdmICcNetworkRate INTEGER, hdmICcBcLinkDly INTEGER, hdmICcDisAnlgOvrDig INTEGER, hdmICcDisAsyncPPP INTEGER, hdmICcDisX75 INTEGER, hdmICcStarV2 INTEGER, hdmICcStarU1 INTEGER, hdmICcStarU2 INTEGER, hdmICcStarU3 INTEGER, hdmICcV120 INTEGER, hdmICcFrameSize INTEGER, hdmICcWindowSize INTEGER } hdmICcIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index which uniquely identifies the modem to which this entry is applicable. The value corresponds to the value of the index to the entity table in the chassis MIB that corresponds to the same modem." ::= { hdmICcEntry 1 } hdmICcIndex2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Secondary Index into the ISDN Call Control table. This index is the value from the chassis mib entity relation table that is applicable for a particular modem." ::= { hdmICcEntry 2 } hdmICcRateAdapV110 OBJECT-TYPE SYNTAX INTEGER{ disable(1), enable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object enables V110 rate adaption corresponds to S register S67 bit 0. Default = 1" ::= { hdmICcEntry 3 } hdmICcFixedNtwkRate OBJECT-TYPE SYNTAX INTEGER{ notForced(1), forceNetworkRate(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object sets the fixed network rate. This object correspond to S register S67 bit 1. Default = 1" ::= { hdmICcEntry 4 } hdmICcNetworkRate OBJECT-TYPE SYNTAX INTEGER{ kbps56(1), kbps64(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object sets the Network rate speed. This object corresponds to the modem S register S67 bit 2. Default = 1" ::= { hdmICcEntry 5 } hdmICcBcLinkDly OBJECT-TYPE SYNTAX INTEGER{ noDelay(1), delay(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object enable a 45 - 65 second link delay. This object corresponds to the S register S67 bit 4. Default = 1" ::= { hdmICcEntry 6 } hdmICcDisAnlgOvrDig OBJECT-TYPE SYNTAX INTEGER{ allow(1), disallow(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to set S register S68 bit 0 which, does not allow analog calls over digital data connection. Default = 1" ::= { hdmICcEntry 7 } hdmICcDisAsyncPPP OBJECT-TYPE SYNTAX INTEGER{ disable(1), enable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to disable/enable async PPP/ sync PPP conversion. This object corresponds to S register S68 bit 4. Default = 1" ::= { hdmICcEntry 8 } hdmICcDisX75 OBJECT-TYPE SYNTAX INTEGER{ disable(1), enable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to disable/enable X75. This object corresponds to S register S68 bit 5. Default = 1" ::= { hdmICcEntry 9 } hdmICcStarV2 OBJECT-TYPE SYNTAX INTEGER{ autodetect(1), v120rateAdapOnly(2), v110rateAdapOnly(3), modemOrFaxOnly(4), clearChannelSync(5), asyncSyncPPPconv(6), x75(7) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to set the data mode of the modem and is equivalent to *V2 = x AT command. Default =1" ::= { hdmICcEntry 10 } hdmICcStarU1 OBJECT-TYPE SYNTAX INTEGER{ none(1), v120(2), x75(3), ppp(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to set the originate HDLC protocols of the modem and is equivalent to *U1 = x AT command. Default =2" ::= { hdmICcEntry 11 } hdmICcStarU2 OBJECT-TYPE SYNTAX INTEGER{ none(1), v110(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to set the originate Non-HDLC protocols of the modem and is equivalent to *U2 = x AT command. Default =1" ::= { hdmICcEntry 12 } hdmICcStarU3 OBJECT-TYPE SYNTAX INTEGER{ none(1), analogModemFax(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to set the originate Analog modem/fax data mode of the modem and is equivalent to *U3 = x AT command. Default =2" ::= { hdmICcEntry 13 } hdmICcV120 OBJECT-TYPE SYNTAX INTEGER{ disable(1), enable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to Enable/Disable V120. This object corresponds to S register 68 bit 4. Default=1." ::= { hdmICcEntry 14 } hdmICcFrameSize OBJECT-TYPE SYNTAX INTEGER (1..2048) ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to set the frame size for X75. Default = 2048." ::= { hdmICcEntry 15 } hdmICcWindowSize OBJECT-TYPE SYNTAX INTEGER (1..7) ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to set the window size of X75. Default=2." ::= { hdmICcEntry 16 } END