-- Copyright 1995 by 3Com Corporation. All rights reserved. -- MIB file name: linkconv.mib -- available in these 3Com devices: LinkConverter -- For support or more info, check 3Com's web page at http://www.3com.com SYNC-RESEARCH-MIB DEFINITIONS ::= BEGIN IMPORTS -- If any of the MIB compilers have problems with the -- internet, mgmt, NetworkAddress, IpAddess, Counter, Gauge, -- TimeTicks, enterprises, uncomment the next two lines and\ -- comment the next third and forth line. --internet, mgmt, NetworkAddress, IpAddress, Counter, Gauge, --TimeTicks, enterprises enterprises, IpAddress, Counter FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 --syncResearch --FROM SYNC-RESEARCH-COMMUNITY-MIB TRAP-TYPE FROM RFC-1215; -- -- Sync Research interNode MIB Version 2.0 -- -- The MIB was developed by Sync Research. It is not compatible -- with prior versions of MIBs published by Sync Research. -- -- The MIB was developed by Sync Research. It is not compatible -- with prior versions of MIBs published by Sync Research. -- -- Last Modification: -- -- 01/27/95 Pam Tossey, Added variables to puControlGroup, and -- netviewControlGroup to count connection attempts. -- Addeded two new traps, puConnectionStatusUp and -- puConnectionStatusDown if the connection state changes for PU, netview -- PUs, and alternate netview PUs. Trap number 808 is no longer generated. -- The varbind list for port and PU traps was changed to include port and -- PU ids. -- -- 12/27/94 Pam Tossey, Modified IMPORTS definitions of the MIB module -- (synccomb.mib) so that it is compiled using Sync's tools (amc). -- MIB module synccomb.mib contains all objects for Sync's MIB and -- Sync Community MIB and Traps. -- -- 12/21/94 Steve Christle, corrected bug in msExtBoardType definition. -- -- 11/17/94 Pam Tossey, Modified password and configpassword to have -- read-write access. -- -- 11/08/94 Pam Tossey, Modified Sync's MIBs to include our OEM partners -- new products. -- -- 08/31/94 Pam Tossey, changed variable access of dateTimeField to -- read-write. -- -- 06/13/94 Steve Christle, Pam Tossey, Sync Research, Version 2.0 -- initial definition supporting FN4R2, CN4 -- -- This MIB module uses the extended OBJECT-TYPE macro as -- defined in RFC1212. -- -- If any of the MIB compilers have problems with the DisplayString -- or PhysAddress, uncomment the next two lines. -- -- DisplayString ::= OCTET STRING -- PhysAddress ::= OCTET STRING -- internet OBJECT IDENTIFIER ::= { iso org(3) dod(6) 1 } -- directory OBJECT IDENTIFIER ::= { internet 1 } -- mgmt OBJECT IDENTIFIER ::= { internet 2 } -- experimental OBJECT IDENTIFIER ::= { internet 3 } -- private OBJECT IDENTIFIER ::= { internet 4 } -- enterprises OBJECT IDENTIFIER ::= { private 1 } syncResearch OBJECT IDENTIFIER ::= { enterprises 485 } -- The next variable agent object ID. syncResearchAgent OBJECT IDENTIFIER ::= { syncResearch 1 } -- The syncProducts group contains both Sync Research's Frame Node and -- Conversion Node. syncProducts OBJECT IDENTIFIER ::= { syncResearchAgent 1 } -- The oemProducts group contains Sync Research's OEM products oemProducts OBJECT IDENTIFIER ::= { syncResearchAgent 2 } -- Subgroup of syncProducts boundary OBJECT IDENTIFIER ::= { syncProducts 1 } centralSite OBJECT IDENTIFIER ::= { syncProducts 2 } -- Subgroups of the Boundary Group syncCN2R2b OBJECT IDENTIFIER ::= { boundary 1 } syncFN2R2b OBJECT IDENTIFIER ::= { boundary 2 } syncCN4R2b OBJECT IDENTIFIER ::= { boundary 3 } syncFN4R2b OBJECT IDENTIFIER ::= { boundary 4 } syncQN4R2b OBJECT IDENTIFIER ::= { boundary 5 } -- Subgroups of the CentralSite Group syncCN4R2c OBJECT IDENTIFIER ::= { centralSite 1 } syncFN4R2c OBJECT IDENTIFIER ::= { centralSite 2 } syncQN4R2c OBJECT IDENTIFIER ::= { centralSite 3 } -- Subgroups of oemProducts threeCom OBJECT IDENTIFIER ::= { oemProducts 1 } cableTron OBJECT IDENTIFIER ::= { oemProducts 2 } chipcom OBJECT IDENTIFIER ::= { oemProducts 3 } -- Subgroups of the threeCom EOM linkConverter OBJECT IDENTIFIER ::= { threeCom 1 } -- Subgroups of the CableTron OEM oemSNACXR2C OBJECT IDENTIFIER ::= { cableTron 1 } oemSNACXR2W OBJECT IDENTIFIER ::= { cableTron 2 } oemSNACMR2C OBJECT IDENTIFIER ::= { cableTron 3 } oemSNACMR2W OBJECT IDENTIFIER ::= { cableTron 4 } -- The Node group contains both the Frame Node and Conversion Node. srNodeGroup OBJECT IDENTIFIER ::= { syncResearch 3 } -- Subgroups of the Node group. nodeUnitGroup OBJECT IDENTIFIER ::= { srNodeGroup 1 } nodeNetViewPUGroup OBJECT IDENTIFIER ::= { srNodeGroup 2 } nodeBridgeGroup OBJECT IDENTIFIER ::= { srNodeGroup 3 } nodeLANGroup OBJECT IDENTIFIER ::= { srNodeGroup 4 } nodeLineGroup OBJECT IDENTIFIER ::= { srNodeGroup 5 } nodePUGroup OBJECT IDENTIFIER ::= { srNodeGroup 6 } nodeDeviceGroup OBJECT IDENTIFIER ::= { srNodeGroup 7 } -- Subgroups of the Unit Group unitControlGroup OBJECT IDENTIFIER ::= { nodeUnitGroup 1 } unitStatusGroup OBJECT IDENTIFIER ::= { nodeUnitGroup 2 } unitConfigGroup OBJECT IDENTIFIER ::= { nodeUnitGroup 3 } unitStatisticsGroup OBJECT IDENTIFIER ::= { nodeUnitGroup 4 } -- Subgroups of the Netview Group netViewPUStatusGroup OBJECT IDENTIFIER ::= { nodeNetViewPUGroup 1 } netViewPUConfigGroup OBJECT IDENTIFIER ::= { nodeNetViewPUGroup 2 } -- Subgroups of the Bridge Group bridgeConfigGroup OBJECT IDENTIFIER ::= { nodeBridgeGroup 1 } -- Subgroups of the LAN Group lanControlGroup OBJECT IDENTIFIER ::= { nodeLANGroup 1 } lanTokenRingGroup OBJECT IDENTIFIER ::= { nodeLANGroup 2 } -- Subgroups of the Line Group lineControlGroup OBJECT IDENTIFIER ::= { nodeLineGroup 1 } linePhysicalGroup OBJECT IDENTIFIER ::= { nodeLineGroup 2 } lineSDLCGroup OBJECT IDENTIFIER ::= { nodeLineGroup 3 } lineBisyncGroup OBJECT IDENTIFIER ::= { nodeLineGroup 4 } lineFrameRelayGroup OBJECT IDENTIFIER ::= { nodeLineGroup 5 } -- Other future Line types (e.g. X.25) would be added here. -- Note Token Ring Statistics are obtained via the 802.5 standard -- MIB as defined in RFC 1231, and Ethernet via 802.3 standard MIB -- Subgroups of the PU Group puControlGroup OBJECT IDENTIFIER ::= { nodePUGroup 1 } puSDLCGroup OBJECT IDENTIFIER ::= { nodePUGroup 2 } puBisyncGroup OBJECT IDENTIFIER ::= { nodePUGroup 3 } puMappingGroup OBJECT IDENTIFIER ::= { nodePUGroup 4 } -- Subgroups of the Device Group deviceControlGroup OBJECT IDENTIFIER ::= { nodeDeviceGroup 1 } deviceBSCGroup OBJECT IDENTIFIER ::= { nodeDeviceGroup 2 } -- The Sync Research Community Name and Trap Group srCommTrapGroup OBJECT IDENTIFIER ::= { syncResearch 2 } commCount OBJECT-TYPE SYNTAX INTEGER (0..32) ACCESS read-only STATUS mandatory DESCRIPTION "The number of possible community name entries in the table." ::= { srCommTrapGroup 1 } commTable OBJECT-TYPE SYNTAX SEQUENCE OF CommEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table houses the information for trivial authentication and sending traps." ::= { srCommTrapGroup 2 } commEntry OBJECT-TYPE SYNTAX CommEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry contains a community name and access code for SNMP trivial authenticationm an enable/disable traps options, as well as network and physical addressing information for traps." INDEX { commIndex } ::= { commTable 1 } CommEntry ::= SEQUENCE { commIndex INTEGER, commName OCTET STRING, commTrap INTEGER, commIPAddr IpAddress, commMACAddr OCTET STRING, commAccess INTEGER } commIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each community entry. Its value ranges between 1 and commCount." ::= { commEntry 1 } commName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "A community name that will be used to access MIB objects within the device. Each community name is associated with an access code of either NO_ACCESS, RO, RW, or SU." ::= { commEntry 2 } commTrap OBJECT-TYPE SYNTAX INTEGER { trapoff(1), trapon(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is checked to determine if traps should be sent to the corresponding network address associated with it." ::= { commEntry 3 } commIPAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The network address of the device that will receive traps from the agent. This IP address also qualifies who may use this community name to access MIB objects. If this community name is use by some one with a different IP address, an Authentication Trap will be generated. If the IP address is set to 0.0.0.0, anyone may use this address, however, traps will not be sent since the address is invalid." ::= { commEntry 4 } commMACAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The physical address of the device receiving traps from the agent." ::= { commEntry 5 } commAccess OBJECT-TYPE SYNTAX INTEGER { noAccess(1), ro(2), rw(3), su(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Access code assiciated with the community name of the same entry. noAccess indicates a community name with zero privileges. ro has read-only access to MIB objects. rw allows you to read and write MIB objects. SU (super- user) gives you privileges to read and write any MIB object. The community table itself can only be written to with an access of SU as well as the setting of the IP Address on a device." ::= { commEntry 6 } -- -- The Unit Control Group -- unitRestart OBJECT-TYPE SYNTAX INTEGER { restart-unit(1), dummy-restart(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this variable to a value of 1 will force the unit to restart. Setting this variable to any other value will cause an SNMP error. This variable always returns a value of 2." ::= { unitControlGroup 1 } dumpOnRestart OBJECT-TYPE SYNTAX INTEGER { dump-on-start(1), dont-dump(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this variable to a value of 1 will force the unit to perform a dump on restart. Setting this variable to a value of 2 will force it to not to dump on restart." ::= { unitControlGroup 2 } initiateInstall OBJECT-TYPE SYNTAX INTEGER { start-install(1), dummy-install(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this variable to a value of 1 will force the unit to initiate an install process. This variable always returns a value of 2." ::= { unitControlGroup 3 } initializeStats OBJECT-TYPE SYNTAX INTEGER { init-stats(1), dummy-init-stats(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this variable to a value of 1 will force the unit to initialize (clear) all statistics kept by the unit. This variable always returns a value of 2." ::= { unitControlGroup 4 } clearDump OBJECT-TYPE SYNTAX INTEGER { clear-dump-file(1), dummy-clear(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this variable to a value of 1 will force the unit to clear a dump. This variable always returns a value of 2." ::= { unitControlGroup 5 } -- -- Unit Status Group -- -- This group contains the device status variables. There exists -- only one instance of this group per unit. -- unitModel OBJECT-TYPE SYNTAX INTEGER { boundary(1), lic(2), chipcomPED(3), snacMIM(4), microMac(5) } ACCESS read-only STATUS mandatory DESCRIPTION "This variable defines the base hardware model of the unit: A boundary platform is the 486 single board unit. A LIC is the Central Site chassis card." ::= { unitStatusGroup 1 } softwareVersion OBJECT-TYPE SYNTAX DisplayString (SIZE(1..6)) ACCESS read-only STATUS mandatory DESCRIPTION "The current version number of the operating software in xx.yyy where xx = major release, yyy = revision." ::= { unitStatusGroup 2 } productType OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) ACCESS read-only STATUS mandatory DESCRIPTION "The product type string returned is set in the MS.SYS file and defines the product." ::= { unitStatusGroup 3 } maxPortNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of ports this unit can support (total number of serial access ports plus total number of LAN ports)." ::= { unitStatusGroup 4 } maxPU OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of PUs this unit can support (total number that can be configured)." ::= { unitStatusGroup 5 } maxSession OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of sessions this unit can support (total number that can be configured)." ::= { unitStatusGroup 6 } maxDevice OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of devices this unit can support (total number that can be configured)." ::= { unitStatusGroup 7 } msBoardType OBJECT-TYPE SYNTAX INTEGER { not-expected(1), two-port-RS232(16), two-port-RS422(17), two-port-V35(18), v35-RS232(22), rs422-RS232(23) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the type of serial I/O ports on main board. It returns 1 if not expected." ::= { unitStatusGroup 8 } msExtBoardType OBJECT-TYPE SYNTAX INTEGER { not-present(1), two-port-RS232(19), two-port-RS422(20), two-port-V35(21), two-port-hspeedRS232(24), two-port-hspeedV35(25) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the type of serial I/O ports on extension board. It returns 1 if not present." ::= { unitStatusGroup 9 } dumpFileStatus OBJECT-TYPE SYNTAX INTEGER { none (1), dump-available(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the presence of a dump file." ::= { unitStatusGroup 10 } dumpFileName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..11)) ACCESS read-only STATUS mandatory DESCRIPTION "The dump file name." ::= { unitStatusGroup 11 } unitSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE(1..9)) ACCESS read-only STATUS mandatory DESCRIPTION "The base unit serial number." ::= { unitStatusGroup 12 } expansionSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE(1..9)) ACCESS read-only STATUS mandatory DESCRIPTION "The expansion board serial number." ::= { unitStatusGroup 13 } romVersion OBJECT-TYPE SYNTAX DisplayString (SIZE(1..16)) ACCESS read-only STATUS mandatory DESCRIPTION "The ROM version number." ::= { unitStatusGroup 14 } processorType OBJECT-TYPE SYNTAX INTEGER { i286 (1), i386 (2), i486SX (3), i486DX (4) } ACCESS read-only STATUS mandatory DESCRIPTION "The base unit processor type." ::= { unitStatusGroup 15 } chassisSlot OBJECT-TYPE SYNTAX INTEGER (1..99) ACCESS read-only STATUS mandatory DESCRIPTION "If the unit is a blade in a chassis, then this variable indicates the slot number. If not applicable, a value of 99 will be returned." ::= { unitStatusGroup 16 } lastTrapSeqNumber OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This entry contains the last sequence number of the last trap generated by the unit. When this value reaches its maximum, it then rolls back to 0." ::= { unitStatusGroup 17 } lastInstallErrCode OBJECT-TYPE SYNTAX INTEGER (0..9999) ACCESS read-only STATUS mandatory DESCRIPTION "This entry contains the status of last install. If the last install was successful, 0 is returned, 9999 indicates installation is in progress, otherwise an error code is returned." ::= { unitStatusGroup 18 } unitPartNumber OBJECT-TYPE SYNTAX DisplayString (SIZE(1..19)) ACCESS read-only STATUS mandatory DESCRIPTION "The base unit part number." ::= { unitStatusGroup 19 } expansionPartNumber OBJECT-TYPE SYNTAX DisplayString (SIZE(1..19)) ACCESS read-only STATUS mandatory DESCRIPTION "The expansion board part number." ::= { unitStatusGroup 20 } -- -- The Unit Configuration Group -- Contains the current operational configuration of the unit unitId OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) ACCESS read-only STATUS mandatory DESCRIPTION "This is the unit id. It consists of a 1 to 8 octet right justified case-sensitive ASCII field which uniquely identifies the unit. This ID is displayed on the LCD display, all system dumps, and any ASCII alarms. The defalult value for this field is startup." ::= { unitConfigGroup 1 } nmsSerialSpeed OBJECT-TYPE SYNTAX INTEGER { speed1200(12), speed2400(24), speed4800(48), speed9600(96), speed19200(192) } ACCESS read-only STATUS mandatory DESCRIPTION "The async serial port speed for NMS console port. The speed is expressed in bits per second (i.e. 9.6 Kbps is represented as 96 decimal). Currently supported speeds are: 1200 2400 4800 9600 19200 Default speed is 9600 bits per second." ::= { unitConfigGroup 2 } serialPortLogoffTimer OBJECT-TYPE SYNTAX INTEGER (0..60) ACCESS read-only STATUS mandatory DESCRIPTION "Units are minutes. Default value is 0, indicating that no timer is active." ::= { unitConfigGroup 3 } callRetryTimer OBJECT-TYPE SYNTAX INTEGER (2..999) ACCESS read-only STATUS mandatory DESCRIPTION "The call retry timer (a.k.a Session Retry Timer). The number of seconds to wait before trying to retry a failed LLC connection attempt. Currently supported values are 2 - 999 seconds. The default is 30 seconds." ::= { unitConfigGroup 4 } password OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) ACCESS read-write STATUS mandatory DESCRIPTION "The unit's password. This field indicates the system password used to log into the unit for operating the NMS interface. This field is a one to eight byte case-sensitive left justified ASCII data field and may not be left blank. The default value is 'sri' (for Sync Research Inc.)." ::= { unitConfigGroup 5 } configPassword OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) ACCESS read-write STATUS mandatory DESCRIPTION "The configuration password. This field indicates the password used to enter the configuration subsystem. This field is a one to eight byte case-sensitive left justified ASCII data field and may not be left blank. The default value is 'sri' (for Sync Research Inc.)." ::= { unitConfigGroup 6 } dateTimeField OBJECT-TYPE SYNTAX OCTET STRING (SIZE(6)) ACCESS read-write STATUS mandatory DESCRIPTION "The date and time. This field is stored as 6 bytes of BCD Data in the following order: Month: 0x01 - 0x12 Day: 0x01 - 0x31 Year: 0x00 - 0x99 Hour: 0x00 - 0x23 Minute: 0x00 - 0x59 Second: 0x00 - 0x59" ::= { unitConfigGroup 7 } configId OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) ACCESS read-only STATUS mandatory DESCRIPTION "The configuration identifer. This field is the configuration ID assigned when a new configuration is activated for the first time. It is assigned by the unit automatically and is not user assignable." ::= { unitConfigGroup 8 } internalMacAddress OBJECT-TYPE SYNTAX PhysAddress ACCESS read-only STATUS mandatory DESCRIPTION "Embedded conversion node MAC address. Applicable to Frame Node only." ::= { unitConfigGroup 9 } internalRingNumber OBJECT-TYPE SYNTAX INTEGER (1..4095) ACCESS read-only STATUS mandatory DESCRIPTION "Embedded conversion node ring number. This should be unique within the network. Applicable to Frame Node only." ::= { unitConfigGroup 10 } internalBridgeNumber OBJECT-TYPE SYNTAX INTEGER (1..15) ACCESS read-only STATUS mandatory DESCRIPTION "Embedded conversion node bridge number. This parameter is currently not used. Applicable to Frame Node only." ::= { unitConfigGroup 11 } -- -- The Unit Statistics Group -- numberSamples OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of internal system level samples performed. Samples are taken every 10th of a second." ::= { unitStatisticsGroup 1 } systemBufferFreeCounts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The average number of system buffers free in the system during the system sample period. The number of available buffers varies by system type and configuration. To determine the maximum number of buffers for a given configuration, view a sample when there is no activity in the unit. A heavily loaded unit will display a small number of available buffers and low Processor Idle counts." ::= { unitStatisticsGroup 2 } cpuIdleSumCounts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The main processor average idle sum count. This is the average number of times the idle counter was incremented over the sampling period divided by 1000. This is an absolute value of performance as does not vary by performance. A heavily loaded unit will display a small number of available buffers and low Processor Idle counts." ::= { unitStatisticsGroup 3 } -- -- NetView PU Status Group -- -- This group contains status variables. There exists -- only one instance of this group per unit. -- netviewConnectionStatus OBJECT-TYPE SYNTAX INTEGER { connected(1), not-connected(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The status of the Primary Netview Connection" ::= { netViewPUStatusGroup 1 } netviewLastClearCode OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2)) ACCESS read-only STATUS mandatory DESCRIPTION "A two octet field indicating the Last Clearing Cause and Diagnostic Field of the last failed primary NetView connection attempt (a.k.a. call attempt) or Netview active connection (a.k.a. session). For LLC type 2 connections the first octet (cause) is always 0. The second octet (diagnostic) indicates the reason for the last connection failure. The second octet is set to 0 when a sucessful call has been placed, or if no call has ever been placed (e.g. PU never came up). If the second octet is non-zero then it indicates the reason for the connection attempt failure. See current product documentation for list of possible values." ::= { netViewPUStatusGroup 2 } netviewAltConnectionStatus OBJECT-TYPE SYNTAX INTEGER { connected(1), not-connected(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The status of the alternate Netview Connection" ::= { netViewPUStatusGroup 3 } netviewAltLastClearCode OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2)) ACCESS read-only STATUS mandatory DESCRIPTION "A two octet field indicating the Last Clearing Cause and Diagnostic Field of the last failed alternate NetView connection attempt (a.k.a. call attempt) or Netview active connection (a.k.a. session). For LLC type 2 connections the first octet (cause) is always 0. The second octet (diagnostic) indicates the reason for the last connection failure. The second octet is set to 0 when a sucessful call has been placed, or if no call has ever been placed (e.g. PU never came up). If the second octet is non-zero then it indicates the reason for the connection attempt failure. See current product documentation for list of possible values." ::= { netViewPUStatusGroup 4 } netviewConnectionAttemptCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of connection attempts performed on the Primary NetView PU. This count is set to zero at startup, and after every loss of an estabished session." ::= { netViewPUStatusGroup 5 } netviewAltConnectionAttemptCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of connection attempts performed on the Alternate NetView PU. This count is set to zero at startup, and after every loss of an estabished session." ::= { netViewPUStatusGroup 6 } -- -- The NetView PU Configuration Group -- Contains the current operational configuration -- netviewPUXID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "Primary NetView PU XID. This field indicates the XID data to be sent to the host for establishing Netview Session. This field is a maximum four byte hexadecimal data field. This field should be set to all zeroes if no Netview session is to be established. The default value is all zeroes." ::= { netViewPUConfigGroup 1 } alternateNetviewPUXID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "Alternate NetView PU XID. This field indicates the XID data to be sent to the host for establishing Netview Session. This field is a maximum four byte hexadecimal data field. This field should be set to all zeroes if no Netview session is to be established. The default value is all zeroes." ::= { netViewPUConfigGroup 2 } netviewConnectID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2)) ACCESS read-only STATUS mandatory DESCRIPTION "The primary NetView PU connection ID. The default value is 0." ::= { netViewPUConfigGroup 3 } alternateNetviewConnectID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2)) ACCESS read-only STATUS mandatory DESCRIPTION "The alternate NetView PU connection ID. The default value is 0." ::= { netViewPUConfigGroup 4 } netviewSpecialConnect OBJECT-TYPE SYNTAX INTEGER { answer (1), originate (2) } ACCESS read-only STATUS mandatory DESCRIPTION "The primary NetView PU connection type. The default value is originate." ::= { netViewPUConfigGroup 5 } alternateNetviewSpecialConnect OBJECT-TYPE SYNTAX INTEGER { answer (1), originate (2) } ACCESS read-only STATUS mandatory DESCRIPTION "The alternate NetView PU connection type. The default value is originate." ::= { netViewPUConfigGroup 6 } -- -- The Bridge Configuration Group -- Contains the current operational configuration -- brEnableBridging OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This flag indicates if bridging is to be performed on this unit. The default value for this field is 'No'" ::= { bridgeConfigGroup 1 } bridgePriority OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Sometimes referred to as the ROOT id. Determines the priority component of the Bridge identifier used in determining the Root Bridge for a spanning tree network." ::= { bridgeConfigGroup 2 } brMaxAge OBJECT-TYPE SYNTAX INTEGER (6..40) ACCESS read-only STATUS mandatory DESCRIPTION "The time at which a configuration message is descarded. Units are in seconds. Default value is 10 seconds" ::= { bridgeConfigGroup 3 } brHelloTimer OBJECT-TYPE SYNTAX INTEGER (1..10) ACCESS read-only STATUS mandatory DESCRIPTION "The time interval between issuing configuration messages. Units are seconds. Default value is 2 seconds" ::= { bridgeConfigGroup 4 } brFilterIPX OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If set to yes, all IPX frames are filtered (if bridge is enabled). Default is Yes." ::= { bridgeConfigGroup 5 } brFilterIP OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If set to yes, all IP frames are filtered (if bridging is enabled). Default is Yes." ::= { bridgeConfigGroup 6 } brFilterNetBIOS OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If set to yes, all NetBIOS frames are filtered (if bridging is enabled). Default is Yes." ::= { bridgeConfigGroup 7 } brFilterLLC2 OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If set to yes, all LAN attached SNA LLC2 frames are filtered (if bridging is enabled). Default is Yes." ::= { bridgeConfigGroup 8 } brFilterSMAN OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If set to yes, all SyncManager LLC2 frames are filtered (if bridging is enabled). Default is Yes." ::= { bridgeConfigGroup 9 } brForwardOther OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If set to yes, all other frames are forwarded (if bridging is enabled). Default is No." ::= { bridgeConfigGroup 10 } brIPXtargetPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "If IPX filtering is set to no, then this parameter defines a specific FR port to deliver IPX frames to. Used in conjunction with brIPXtargetDLCI. The valid range is 0 to 5. A value of 0 indicates that the IPX target port/DLCI is not configured. This field has the default value of 0." ::= { bridgeConfigGroup 11 } brIPXtargetDLCI OBJECT-TYPE SYNTAX INTEGER (1..1023) ACCESS read-only STATUS mandatory DESCRIPTION "If IPX filtering is set to no, then this parameter defines a specific FR DLCI to deliver IPX frames to. Used in conjunction with brIPXtargetPort. If the value of brIPXtargetport is 0, then the value of brIPXtargetDLCI is not significant." ::= { bridgeConfigGroup 12 } brIPtargetPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "If IP filtering is set to no, then this parameter defines a specific FR port to deliver IP frames to. Used in conjunction with brIPtargetDLCI. The valid range is 0 to 5. A value of 0 indicates that the IP target port/DLCI is not configured. This field has the default value of 0." ::= { bridgeConfigGroup 13 } brIPtargetDLCI OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "If IP filtering is set to no, then this parameter defines a specific FR DLCI to deliver IP frames to. Used in conjunction with brIPtargetPort. If the value of brIPtargetport is 0, then the value of brIPtargetDLCI is not significant." ::= { bridgeConfigGroup 14 } brNetBIOStargetPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "If NetBIOS filtering is set to no, then this parameter defines a specific FR port to deliver NetBIOS frames to. Used in conjunction with brNetBIOStargetDLCI. The valid range is 0 to 5. A value of 0 indicates that the NetBIOS target port/DLCI is not configured. This field has the default value of 0." ::= { bridgeConfigGroup 15 } brNetBIOStargetDLCI OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "If NetBIOS filtering is set to no, then this parameter defines a specific FR DLCI to deliver NetBIOS frames to. Used in conjunction with brNetBIOStargetPort. If the value of brNetBIOStargetport is 0, then the value of brNetBIOStargetDLCI is not significant." ::= { bridgeConfigGroup 16 } brLLC2targetPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "If SNA LLC2 filtering is set to no, then this parameter defines a specific FR port to deliver LLC2 frames to. Used in conjunction with brLLC2targetDLCI. The valid range is 0 to 5. A value of 0 indicates that the brLLC2targetport/brLLC2targetDLCI is not configured. This field has the default value of 0." ::= { bridgeConfigGroup 17 } brLLC2targetDLCI OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "If SNA LLC2 filtering is set to no, then this parameter defines a specific FR DLCI to deliver LLC2 frames to. Used in conjunction with brLLC2targetPort. If the value of brLLC2targetport is 0, then the value of brLLC2targetDLCI is not significant." ::= { bridgeConfigGroup 18 } brOthertargetPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "If Other forwarding is set to yes, then this parameter defines a specific FR port to deliver Other frames to. Used in conjunction with brOthertargetDLCI. The valid range is 0 to 5. The value 0 indicates that the brOthertargetport/brOthertargetDLCI is not configured. This field has the default value of 0." ::= { bridgeConfigGroup 19 } brOthertargetDLCI OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "If Other forwarding is set to yes, then this parameter defines a specific FR DLCI to deliver Other frames to. Used in conjunction with brOthertargetPort. If the value of brOthertargetport is 0, then the value of brOthertargetDLCI is not significant." ::= { bridgeConfigGroup 20 } brSerialPriority OBJECT-TYPE SYNTAX INTEGER { urgent (1), high (2), medium (3), low (4) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter defines the transmit priority for Frame Relay of serial attached port traffic." ::= { bridgeConfigGroup 21 } brTerminatedLLC2Priority OBJECT-TYPE SYNTAX INTEGER { urgent (1), high (2), medium (3), low (4) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter defines the transmit priority for Frame Relay of terminated LLC2 traffic." ::= { bridgeConfigGroup 22 } brLLC2Priority OBJECT-TYPE SYNTAX INTEGER { urgent (1), high (2), medium (3), low (4) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter defines the transmit priority for Frame Relay of SNA LLC2 traffic." ::= { bridgeConfigGroup 23 } brIPXPriority OBJECT-TYPE SYNTAX INTEGER { urgent (1), high (2), medium (3), low (4) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter defines the transmit priority for Frame Relay of IPX traffic." ::= { bridgeConfigGroup 24 } brIPPriority OBJECT-TYPE SYNTAX INTEGER { urgent (1), high (2), medium (3), low (4) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter defines the transmit priority for Frame Relay of IP traffic." ::= { bridgeConfigGroup 25 } brNetBIOSPriority OBJECT-TYPE SYNTAX INTEGER { urgent (1), high (2), medium (3), low (4) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter defines the transmit priority for Frame Relay of NetBIOS traffic." ::= { bridgeConfigGroup 26 } brOtherPriority OBJECT-TYPE SYNTAX INTEGER { urgent (1), high (2), medium (3), low (4) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter defines the transmit priority for Frame Relay of other traffic." ::= { bridgeConfigGroup 27 } brHighPriorityBandwidth OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "This parameter defines the high priority bandwidth. The sum of high, medium, and low priority bandwidth cannot exceed 100. Default value is 40." ::= { bridgeConfigGroup 28 } brMediumPriorityBandwidth OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "This parameter defines the medium priority bandwidth. The sum of high, medium, and low priority bandwidth cannot exceed 100. Default value is 30." ::= { bridgeConfigGroup 29 } brLowPriorityBandwidth OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "This parameter defines the low priority bandwidth. The sum of high, medium, and low priority bandwidth cannot exceed 100. Default value is 20." ::= { bridgeConfigGroup 30 } -- -- The LAN control -- lanControlTable OBJECT-TYPE SYNTAX SEQUENCE OF LanControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table for controlling LAN ports and obtaining information." ::= { lanControlGroup 1 } lanControlEntry OBJECT-TYPE SYNTAX LanControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry consisting of port information for a particular LAN port." INDEX { lanControlIndex } ::= { lanControlTable 1 } LanControlEntry ::= SEQUENCE { lanControlIndex INTEGER, lanControlType INTEGER, lanStatus INTEGER, lanControlFailureCode OCTET STRING, lanControlNAUName DisplayString } lanControlIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number that uniquely identifies this LAN port. Currently only one LAN port per unit is supported." ::= { lanControlEntry 1 } lanControlType OBJECT-TYPE SYNTAX INTEGER { token-ring-type(21), ethernet-type(17) } ACCESS read-only STATUS mandatory DESCRIPTION "The LAN type. Token-Ring ports run the IEEE 802.5 protocol. Ethernet-type run the IEEE 802.3 and Ethernet Version 2. Other LAN protocols may be added in the future." ::= { lanControlEntry 2 } lanStatus OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2), failed(3), restart(4) } ACCESS read-write STATUS mandatory DESCRIPTION "The status of the port. To change status of a port an enable, enable all or disable may be set. Valid Return status are enable(d), disable(d), or failed. Commands: An enable command will attempt to bring up the LAN. An enable all command will perform the same function as enable, since there are no sub elements on a LAN. A disable command will disable the LAN. Status: Enable(d) indicates the LAN is enabled and running. Disable(d) indicates the LAN has been disabled. Failed indicates the LAN is enabled and not Running." ::= { lanControlEntry 3 } lanControlFailureCode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (2)) ACCESS read-only STATUS mandatory DESCRIPTION "This entry contains the failure codes if the associated LAN interface is in the failed state." ::= { lanControlEntry 4 } lanControlNAUName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) ACCESS read-only STATUS mandatory DESCRIPTION "The NAU name of this port. The default value for this field is all blank (filled with ASCII space 0x20 characters)." ::= { lanControlEntry 5 } -- -- The LAN Configuration Group -- lanPortTable OBJECT-TYPE SYNTAX SEQUENCE OF LanPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of LAN information." ::= { lanTokenRingGroup 1 } lanPortEntry OBJECT-TYPE SYNTAX LanPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry consisting of port information for a particular LAN port." INDEX { lanPortIndex } ::= { lanPortTable 1 } LanPortEntry ::= SEQUENCE { lanPortIndex INTEGER, lanPortType INTEGER, lanMACAddress PhysAddress, lanPROMMACAddress PhysAddress, lanSpeed INTEGER, lanT1Timer INTEGER, lanT2Timer INTEGER, lanTiTimer INTEGER, lanRxWindowSize INTEGER, lanTxWindowSize INTEGER, lanMaxRetries INTEGER, lanRingNumber INTEGER, lanBridgeNumber INTEGER, lanEthernetFrameFormat INTEGER, lanSendLocalTest INTEGER, lanBroadcastType INTEGER, lanIPAddress IpAddress, lanNetworkMask IpAddress, lanDefaultGateway IpAddress, lanNAUName DisplayString, lanInterfaceType INTEGER, lanIPEthernetFrameType INTEGER, lanInitState INTEGER } lanPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number that uniquely identifies this port. Currently only one LANtoken ring port per unit is supported with the port index = 1." ::= { lanPortEntry 1 } lanPortType OBJECT-TYPE SYNTAX INTEGER { token-ring-type(21), ethernet-type(17) } ACCESS read-only STATUS mandatory DESCRIPTION "The LAN port type." ::= { lanPortEntry 2 } lanMACAddress OBJECT-TYPE SYNTAX PhysAddress ACCESS read-only STATUS mandatory DESCRIPTION "The user configured LANtoken ring MAC address. If the address is set to 0 then the burned-in Address is used. This field contains a user configured address if any. If a user configured address is desired, then it must be configured as a valid individual, user defined - MAC address. The address must be configured in the native format convention used by the LAN port. For token Ring LAN ports the address follows User configured addresses must follow IEEE 802.5 IEEE 802.5 rules (most significant bit transmitted first) and must be between 400000000000 and 7FFFFFFFFFFF hexadecimal inclusive. For Ethernet LAN ports the format is must follow IEEE 802.3 rules.where the two least significant bits of the first octet must be zero. This means the first octet must be in the set of numbers 0x00, 0x04, 0x08, ... 0xFC..... The Default Value for this field is all zeroes." ::= { lanPortEntry 3 } lanPROMMACAddress OBJECT-TYPE SYNTAX PhysAddress ACCESS read-only STATUS mandatory DESCRIPTION "The burned in MAC address. This is the MAC address assigned by the factory when the unit is shipped. If the User configured address is set to 0, then this will be the address used by the adapter for the source address field for all frames sent by the LAN adapter. The format ordering of bits is as defined in IEEE 802.5. This ordering is where the Most Significant Bit is transmitted first. This is different from other protocols (e.g. 802.3) where the least significant bit is transmitted first. The representation of the MAC address is in the format native for the LAN port. Boundary platform Token-Ring LAN ports start with the first six digits (three octects) equal to 0002F6 which indicates a Sync Research Token Ring MAC address. Boundary platform Ethernet LAN ports start with the first six digits (three octects) equal to to 00406F which indicates a Sync Research Ethernet MAC address. This field is not changable via any commands and will always contain the manufactured MAC address for the LAN port." ::= { lanPortEntry 4 } lanSpeed OBJECT-TYPE SYNTAX INTEGER { speed-4Mbs(4), speed-10Mbs(10), speed-16Mbs(16) } ACCESS read-only STATUS mandatory DESCRIPTION "The LAN port speed in Megabits/second. For Token-Ring boundary platforms, the speed is changable via the front panel keypad and LCD menus, and NMS console port. For Token-Ring LIC the speed is changed by a jumper on the back of the board (top two pins = 4, bottom two pins = 16). For Ethernet boundary platforms and LIC, the speed is not configurable." ::= { lanPortEntry 5 } lanT1Timer OBJECT-TYPE SYNTAX INTEGER (1..25) ACCESS read-only STATUS mandatory DESCRIPTION "The default LLC T1 timer value in seconds. T1 should be greater than T2 and less than Ti. Currently supported values are 1 to 25 seconds. The default value for this field is 3 seconds." ::= { lanPortEntry 6 } lanT2Timer OBJECT-TYPE SYNTAX INTEGER (0..50) ACCESS read-only STATUS mandatory DESCRIPTION "The default LLC T2 timer value in tenths of seconds. If configured for 0 then the T2 timer is disabled and an RR frame will be sent for every I frame received. Current supported values are 0 and 2-50. T2 should be less than T1. The default value for this field is 0 (disabled)." ::= { lanPortEntry 7 } lanTiTimer OBJECT-TYPE SYNTAX INTEGER (2..50) ACCESS read-only STATUS mandatory DESCRIPTION "The default LLC Ti (inactivity) timer value in seconds. Ti should be greater than T1. Currently supported values are 2 to 50 seconds. The default value for this field is 30 seconds." ::= { lanPortEntry 8 } lanRxWindowSize OBJECT-TYPE SYNTAX INTEGER (1..7) ACCESS read-only STATUS mandatory DESCRIPTION "The default LLC receive window (N3) size. Note that this is not the same receive window as defined in IEEE 802.2 LLC. This is N3 which is the number of I frames received before an RR frame is sent (defined as N3 in IEEE 802.2 LLC). Current allowable values are 1-7. The default value for this field is 7." ::= { lanPortEntry 9 } lanTxWindowSize OBJECT-TYPE SYNTAX INTEGER (1..7) ACCESS read-only STATUS mandatory DESCRIPTION "The defalut LLC transmit window size. Current allowable values are 1-7. The default value for this field is 7." ::= { lanPortEntry 10 } lanMaxRetries OBJECT-TYPE SYNTAX INTEGER (1..99) ACCESS read-only STATUS mandatory DESCRIPTION "The default LLC maximum number of retries (N2 value). Current allowable values are 1-99. The default value for this field is 3." ::= { lanPortEntry 11 } lanRingNumber OBJECT-TYPE SYNTAX INTEGER (0..4095) ACCESS read-only STATUS mandatory DESCRIPTION "802.5 bridging parameter. This variable returns a value of 0, if it is not defined. This value is not applicable to Ethernet." ::= { lanPortEntry 12 } lanBridgeNumber OBJECT-TYPE SYNTAX INTEGER (1..15) ACCESS read-only STATUS mandatory DESCRIPTION "802.5 bridging parameter. The default value for this field is 1. This value is not applicable to Ethernet." ::= { lanPortEntry 13 } lanEthernetFrameFormat OBJECT-TYPE SYNTAX INTEGER { not-applicable(1), e802-3-type(2), ethernet-type-2(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The Ethernet frame format used on this LAN. The default value for this field is 802.3. Not used if Token Ring, and 1 is returned." ::= { lanPortEntry 14 } lanSendLocalTest OBJECT-TYPE SYNTAX INTEGER { not-applicable(1), yes(2), no(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This port's send local test option. Identifies whether a test frame should be sent on the local ring to discover a destination MAC address. If all destinations for the unit are located on a remote ring, setting this field to No allows the unit to bypass discovery of a destination MAC address on the local ring. If this field is set to 'No' then the broadcastType field must be set to all routes or single route broadcast. If the any destination is on a local ring or unknown, this parameter should be set to 'Yes'. The default value for this field is 'Yes'. Not used if Ethernet, and 1 is returned." ::= { lanPortEntry 15 } lanBroadcastType OBJECT-TYPE SYNTAX INTEGER { not-applicable(1), none-bc(2), all-bc(3), single-bc(4) } ACCESS read-only STATUS mandatory DESCRIPTION "This port's broadcast type. Not used if Ethernet. Types are: none, all-routes, and single-route. Identifies the form of a broadcast test frame sent to discover the route to a destination MAC address. If all destinations are located on the local ring, this field may be set to 'None' to prevent a broadcast search for a destination MAC address. If set to 'None', then the sendLocalTest field must be set to 'Yes'. If set as 'All-routes', the unit will send an All-routes broadcast TEST command frame and expect a non-broadcast TEST response frame in return. If set to Single-route, the unit will send a Single-route broadcast TEST command frame and expect a all-routes TEST response frame in return. The default for this field is all routes broadcast. Not used if Ethernet, and 1 is returned." ::= { lanPortEntry 16 } lanIPAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "This is the IP Address of this interface." ::= { lanPortEntry 17 } lanNetworkMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "This is the network mask to be used on this interface." ::= { lanPortEntry 18 } lanDefaultGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Default gateway address to be used when sending responses on this interface." ::= { lanPortEntry 19 } lanNAUName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) ACCESS read-only STATUS mandatory DESCRIPTION "The NAU name of this port. The default value for this field is all blank (filled with ASCII space 0x20 characters)." ::= { lanPortEntry 20 } lanInterfaceType OBJECT-TYPE SYNTAX INTEGER { not-applicable(1), aui(2), bnc(3), utp(4) } ACCESS read-only STATUS mandatory DESCRIPTION "This port's physical interface type. Only used if Ethernet. The default for this field is utp. Not used if Token Ring, and 1 is returned." ::= { lanPortEntry 21 } lanIPEthernetFrameType OBJECT-TYPE SYNTAX INTEGER { not-applicable(1), e802-3-type(2), ethernet-type-2(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The IP Ethernet frame format used on this LAN for IP frames. The default value for this field is 802.3. Not used if Token Ring, and 1 is returned." ::= { lanPortEntry 22 } lanInitState OBJECT-TYPE SYNTAX INTEGER { in-service(1), out-of-service(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The initial state of the LAN port. If configured for 'in-service', then the LAN port will be brougt up automattically when the unit is powered up. If configured for 'out-of-service', the the LAN port must be manually enabled by operator intervention (i.e. enable command must be sent). The default value is 'enabled'." ::= { lanPortEntry 23 } -- -- The Line Control Group -- lineControlTable OBJECT-TYPE SYNTAX SEQUENCE OF LineControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table for controlling lines and obtaining information." ::= { lineControlGroup 1 } lineControlEntry OBJECT-TYPE SYNTAX LineControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry consisting of port information for a particular port." INDEX { lineControlIndex } ::= { lineControlTable 1 } LineControlEntry ::= SEQUENCE { lineControlIndex INTEGER, lineControlType INTEGER, lineStatus INTEGER, lineControlFailureCode OCTET STRING, lineControlNAUName DisplayString } lineControlIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number that uniquely identifies this port." ::= { lineControlEntry 1 } lineControlType OBJECT-TYPE SYNTAX INTEGER { hbsc-type(1), tbsc-type(2), hsdlc-type(11), tsdlc-type(12), frameRelay-type(19) } ACCESS read-only STATUS mandatory DESCRIPTION "The port type. TSDLC (Terminal SDLC) ports emulate a Host and poll the downstream PUs (e.g. 3274 or 3174 SDLC/SNA controllers). HSDLC ports (Host SDLC) ports emulate a line with Terminal Controllers (PUs) and respond to polls from the Host or upstream PU. TBSC (Terminal Bisync) ports emulate a Host and poll the downstream CUs (e.g. 3274 or ATM Bisync controllers). HBSC ports (Host Bisync) ports emulate a line with Terminal Controllers (CUs) and respond to polls from the Host or upstream CU. Frame Relay ports support Frame Relay PVC. Future line types (e.g. X.25) may be added here." ::= { lineControlEntry 2 } lineStatus OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2), failed(3), restart(4), enable-all(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The status of the port. To change status of a port an enable, enable all or disable may be set. Valid Return status are enable(d), disable(d), or failed. Commands: An enable command will attempt to bring up the line. An enable all command will attempt to bring up the line and any lower layer entities (e.g. PUs). A disable command will disable the line. Status: Enable(d) indicates the line is enabled and running. Disable(d) indicates the line has been disabled. Failed indicates the line is enabled and not Running." ::= { lineControlEntry 3 } lineControlFailureCode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (2)) ACCESS read-only STATUS mandatory DESCRIPTION "This entry contains the failure codes if the associated port interface is in the failed state." ::= { lineControlEntry 4 } lineControlNAUName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) ACCESS read-only STATUS mandatory DESCRIPTION "The NAU name of this port. The default value for this field is all blank (filled with ASCII space 0x20 characters)." ::= { lineControlEntry 5 } -- -- The Line Physical Control Group -- -- This is a separate group as not all 'lines' have an RS-232 -- or other WAN physical interface (e.g. V.35, RS-449 etc.) -- linePhysicalTable OBJECT-TYPE SYNTAX SEQUENCE OF LinePhysicalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table for obtaining physical signal status information." ::= { linePhysicalGroup 1 } linePhysicalEntry OBJECT-TYPE SYNTAX LinePhysicalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry consisting of port information for a particular port." INDEX { linePhysicalIndex } ::= { linePhysicalTable 1 } LinePhysicalEntry ::= SEQUENCE { linePhysicalIndex INTEGER, linePhysicalType INTEGER, lineEIAStatus INTEGER, lineQualityFrameCount Counter, lineQualityCRCErrors Counter, lineQualityAborts Counter } linePhysicalIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number that uniquely identifies this port." ::= { linePhysicalEntry 1 } linePhysicalType OBJECT-TYPE SYNTAX INTEGER { tbsc-type(1), hbsc-type(2), frameRelay-type(19), hsdlc-type(11), tsdlc-type(12) } ACCESS read-only STATUS mandatory DESCRIPTION "The port type. TSDLC (Terminal SDLC) ports emulate a Host and poll the downstream PUs (e.g. 3274 or 3174 SDLC/SNA controllers). HSDLC ports (Host SDLC) ports emulate a line with Terminal Controllers (PUs) and respond to polls from the Host or upstream PU. TBSC (Terminal Bisync) ports emulate a Host and poll the downstream CUs (e.g. 3274 or ATM Bisync controllers). HBSC ports (Host Bisync) ports emulate a line with Terminal Controllers (CUs) and respond to polls from the Host or upstream CU. Frame Relay ports support Frame Relay PVC." ::= { linePhysicalEntry 2 } lineEIAStatus OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "A port's current control signal status. All SDLC ports have the ability to read the current status of RS-232 or equivalent control signals. The value returned is a 16 bit value where each bit signifies a signal status where 1 means the signal is active and 0 means the signal is inactive. The value returned is a snapshot taken when the command actually is sent to the driver software and wherever possible actually goes out to the driver or receiver control chips to get the value. Currently defined bit values are as follows*: 128 : Data Terminal Ready 0x0080 RS-232 pin 20 64 : Data Set Ready 0x0040 RS-232 pin 6 32 : Clear to Send 0x0020 RS-232 pin 5 16 : Clear to Send Ext. 0x0010 RS-232 pin 11** 8 : Data Carrier Detect 0x0008 RS-232 pin 8 4 : Busy Out 0x0004 RS-232 pin 25 2 : Request to send 0x0002 RS-232 pin 4 1 : Ring Indicator 0x0001 RS-232 pin 22 Note*: Bit values higher than 128 are reserved for future use. Note**: Clear to Send External is extended (non- standard) pin and reserved for future use by Sync Research." ::= { linePhysicalEntry 3 } lineQualityFrameCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This entry contains the number of frames received. For every 255 incoming frames, a trap is generated by the unit if lineQualityCRCErrors or lineQualityAborts exceeds 5. When this value reaches its maximum, it then rolls back to 0. Applicable to SDLC only." ::= { linePhysicalEntry 4} lineQualityCRCErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This entry contains the number of frames with CRC errors. For every 255 incoming frames, a trap is generated by the unit if lineQualityCRCErrors or lineQualityAborts exceeds 5. Applicable to SDLC only." ::= { linePhysicalEntry 5 } lineQualityAborts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This entry contains the number of aborts received. For every 255 incoming frames, a trap is generated by the unit if lineQualityCRCErrors or lineQualityAborts exceeds 5. Applicable to SDLC only." ::= { linePhysicalEntry 6 } -- -- The SDLC Port Level Configuration Group -- -- -- The SDLC Configuration Table: -- sdlcConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF SdlcConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of SDLC information." ::= { lineSDLCGroup 1 } sdlcConfigEntry OBJECT-TYPE SYNTAX SdlcConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry consisting of port information for a particular SDLC port." INDEX { sdlcConfigPortIndex } ::= { sdlcConfigTable 1 } SdlcConfigEntry ::= SEQUENCE { sdlcConfigPortIndex INTEGER, sdlcConfigType INTEGER, sdlcInitState INTEGER, sdlcCarrier INTEGER, sdlcClocking INTEGER, sdlcSpeed INTEGER, sdlcPause INTEGER, sdlcNRZI INTEGER, sdlcT1Timer INTEGER, sdlcSlowPollTimer INTEGER, sdlcMaxRetries INTEGER, sdlcNAUName DisplayString, sdlcMultiFlagInsertion INTEGER } sdlcConfigPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number that uniquely identifies this port. Current supported SDLC numbers are 1-4." ::= { sdlcConfigEntry 1 } sdlcConfigType OBJECT-TYPE SYNTAX INTEGER { hsdlc-type(11), tsdlc-type(12) } ACCESS read-only STATUS mandatory DESCRIPTION "The port type. TSDLC (Terminal SDLC) ports emulate a Host and poll the downstream PUs (e.g. 3274 or 3174 SDLC/SNA controllers). HSDLC ports (Host SDLC) ports emulate a line with Terminal Controllers (PUs) and respond to polls from the Host or upstream PU. Note that all ports must currently be defined as the same time for a given unit (i.e. no mixing of HSDLC and TSDLC ports is allowed)." ::= { sdlcConfigEntry 2 } sdlcInitState OBJECT-TYPE SYNTAX INTEGER { in-service(1), out-of-service(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The initial state of the SDLC port. If configured for 'in-service', then the SDLC port will be brougt up automattically when the unit is powered up. If configured for 'out-of-service', the the SDLC port must be manually enabled by operator intervention (i.e. enable command must be sent). The default value is 'enabled'." ::= { sdlcConfigEntry 3 } sdlcCarrier OBJECT-TYPE SYNTAX INTEGER { constant(1), switched(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This field indicates whether Carrier (a.k.a. CD or DCD, RS-232 pin 8) is constant or switched for DCE devices (internally clocked), or Request To Send (a.k.a. RTS, RS-232 pin 4) is constant or switched. This parameter also affects SDLC flag generation. If configured for constant then the line will transmit flags in an idle (no data being sent) state. If configured for switched then the line will transmit all one bits (mark state). The default value for this parameter is 'constant'." ::= { sdlcConfigEntry 4 } sdlcClocking OBJECT-TYPE SYNTAX INTEGER { external(1), internal(2), x21-external(3), x21-internal(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Clocking source for this port. Setting 'internal' will cause the port to emulate a physical DCE, and setting external will cause the port to emulate a physical DTE. X21 External and Internal are used (with the proper external adapter) to support X.21 Leased Line operation for RS-422/RS-530 (25 pin balanced) interfaces. X21 operation is not supported for boards that operate RS-232 or V.35. The default value for this field is 'external'." ::= { sdlcConfigEntry 5 } sdlcSpeed OBJECT-TYPE SYNTAX INTEGER -- { -- speed1200(12), -- speed2000(20), -- speed2400(24), -- speed3600(36), -- speed4800(48), -- speed7200(72), -- speed9600(96), -- speed14400(144), -- speed19200(192), -- speed28800(288), -- speed48000(480), -- speed56000(560), -- speed64000(640), -- speed128000(1280) -- } ACCESS read-only STATUS mandatory DESCRIPTION "The ports speed in bits per second. The default value is 9600 bits per second. Speeds higher than 19200 are not supported on RS-232 ports units (must be V.35 or RS-422)." ::= { sdlcConfigEntry 6 } sdlcPause OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This parameter defines the amount of time between polls in 1/100 second (10 millisecond) intervals. If set to zero then the port will poll the PUs as fast as possible. The minimum value for this parameter is 5 and the timer has a resolution of 25 milliseconds. The default value is 20 (.20 seconds). This field is not applicable to Host port. It returns a dummy value." ::= { sdlcConfigEntry 7 } sdlcNRZI OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter indicates whether the port is configured for NRZI (yes) or NRZ (no) bit encoding. The default value is 'No' (NRZ encoding selected)." ::= { sdlcConfigEntry 8 } sdlcT1Timer OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The SDLC T1 timer value in 20ths of a second. The default value is 20 (5 seconds). This field is not applicable to Host ports. It returns a dummy value." ::= { sdlcConfigEntry 9 } sdlcSlowPollTimer OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The slow poll timer value in 20ths of a second. The slow poll timer is the amount of time to wait to contact (send SNRM) failed PUs. The default value for this field is 600 (30 seconds). This field is not applicable to Host ports. It returns a dummy value." ::= { sdlcConfigEntry 10 } sdlcMaxRetries OBJECT-TYPE SYNTAX INTEGER (1..99) ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of retries (N2 value) before failing a PU. The default value for this field is 3. This field is not applicable to Host ports. It returns a dummy value." ::= { sdlcConfigEntry 11 } sdlcNAUName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) ACCESS read-only STATUS mandatory DESCRIPTION "The NAU name of this port. The default value for this field is all blank (filled with ASCII space 0x20 characters)." ::= { sdlcConfigEntry 12 } sdlcMultiFlagInsertion OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter indicates whether the port is configured to send multiple interframe flags. The default value is 'No' (single flags)." ::= { sdlcConfigEntry 13 } -- -- The SDLC Port Statistics Table: -- sdlcStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF SdlcStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of SDLC information." ::= { lineSDLCGroup 2 } sdlcStatsEntry OBJECT-TYPE SYNTAX SdlcStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry consisting of port information for a particular SDLC port." INDEX { sdlcStatsPortIndex } ::= { sdlcStatsTable 1 } SdlcStatsEntry ::= SEQUENCE { sdlcStatsPortIndex INTEGER, sdlcPortType INTEGER, sdlcInOctets Counter, sdlcOutOctets Counter, sdlcInFrames Counter, sdlcOutFrames Counter, sdlcOverruns Counter, sdlcCRCErrors Counter, sdlcRecvAborts Counter } sdlcStatsPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number that uniquely identifies this SDLC port. Current supported numbers on are 1-4." ::= { sdlcStatsEntry 1 } sdlcPortType OBJECT-TYPE SYNTAX INTEGER { hsdlc-type(11), tsdlc-type(12) } ACCESS read-only STATUS mandatory DESCRIPTION "The port type. TSDLC (Terminal SDLC) ports emulate a Host and poll the downstream PUs (e.g. 3274 or 3174 SDLC/SNA controllers). HSDLC ports (Host SDLC) ports emulate a line with Terminal Controllers (PUs) and respond to polls from the Host or upstream PU." ::= { sdlcStatsEntry 2 } sdlcInOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of bytes received." ::= { sdlcStatsEntry 3 } sdlcOutOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of bytes sent." ::= { sdlcStatsEntry 4 } sdlcInFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of I-frames received." ::= { sdlcStatsEntry 5 } sdlcOutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of I-frames sent." ::= { sdlcStatsEntry 6 } sdlcOverruns OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of overruns." ::= { sdlcStatsEntry 7 } sdlcCRCErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of CRC errors." ::= { sdlcStatsEntry 8 } sdlcRecvAborts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of aborts received." ::= { sdlcStatsEntry 9 } -- -- The Bisync Port Level Group -- -- -- The Bisync Configuration Table: -- bisyncConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF BisyncConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of Bisync port information." ::= { lineBisyncGroup 1 } bisyncConfigEntry OBJECT-TYPE SYNTAX BisyncConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry consisting of port information for a particular Bisync port." INDEX { bisyncConfigPortIndex } ::= { bisyncConfigTable 1 } BisyncConfigEntry ::= SEQUENCE { bisyncConfigPortIndex INTEGER, bisyncConfigType INTEGER, bisyncNAUName DisplayString, bisyncInitState INTEGER, bisyncCarrier INTEGER, bisyncClocking INTEGER, bisyncSpeed INTEGER, bisyncPause INTEGER, bisyncReplyTimer INTEGER, bisyncRetries INTEGER, bisyncSlowpollTimer INTEGER, bisyncSessTerm INTEGER } bisyncConfigPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number that uniquely identifies this port. Current supported Bisync numbers are 1-4." ::= { bisyncConfigEntry 1 } bisyncConfigType OBJECT-TYPE SYNTAX INTEGER { hbsc-type(1), tbsc-type(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The port type. TBSC (Terminal Bisync) ports emulate a Host and polls the downstream controllers). HBSC ports (Host Bisync) ports emulate a line with Terminal Controllers (CUs) and respond to polls from the Host." ::= { bisyncConfigEntry 2 } bisyncNAUName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) ACCESS read-only STATUS mandatory DESCRIPTION "The NAU name of this port. The default value for this field is all blank (filled with ASCII space 0x20 characters)." ::= { bisyncConfigEntry 3 } bisyncInitState OBJECT-TYPE SYNTAX INTEGER { in-service(1), out-of-service(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The initial state of the Bisync port. If configured for 'in-service', then the Bisync port will be brougt up automattically when the unit is powered up. If configured for 'out-of-service', then the Bisync port must be manually enabled by operator intervention (i.e. enable command must be sent). The default value is 'enabled'." ::= { bisyncConfigEntry 4 } bisyncCarrier OBJECT-TYPE SYNTAX INTEGER { constant(1), switched(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This field indicates whether Carrier (a.k.a. CD or DCD, RS-232 pin 8) is constant or switched for DCE devices (internally clocked), or Request To Send (a.k.a. RTS, RS-232 pin 4) is constant or switched. The default value for this parameter is 'constant'." ::= { bisyncConfigEntry 5 } bisyncClocking OBJECT-TYPE SYNTAX INTEGER { external(1), internal(2), x21-external(3), x21-internal(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Clocking source for this port. Setting 'internal' will cause the port to emulate a physical DCE, and setting external will cause the port to emulate a physical DTE. X21 External and Internal are used (with the proper external adapter) to support X.21 Leased Line operation for RS-422/RS-530 (25 pin balanced) interfaces. X21 operation is not supported for boards that operate RS-232 or V.35. The default value for this field is 'external'." ::= { bisyncConfigEntry 6 } bisyncSpeed OBJECT-TYPE SYNTAX INTEGER -- { -- speed1200(12), -- speed2000(20), -- speed2400(24), -- speed3600(36), -- speed4800(48), -- speed7200(72), -- speed9600(96), -- speed14400(144), -- speed19200(192), -- speed28800(288), -- speed48000(480), -- speed56000(560), -- speed64000(640) -- } ACCESS read-only STATUS mandatory DESCRIPTION "The ports speed in bits per second. The default value is 9600 bits per second. Speeds higher than 64000 are not supported." ::= { bisyncConfigEntry 7 } bisyncPause OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This parameter defines the amount of time between polls in 1/100 second (10 millisecond) intervals. If set to zero then the port will poll the CUs as fast as possible. The minimum value for this parameter is 5 and the timer has a resolution of 25 milliseconds. The default value is 20 (.20 seconds). This field is not applicable to a Host port. It returns a dummy value." ::= { bisyncConfigEntry 8 } bisyncReplyTimer OBJECT-TYPE SYNTAX INTEGER (1..99) ACCESS read-only STATUS mandatory DESCRIPTION "The time to wait for a response in seconds. The default value for this field is 3 seconds." ::= { bisyncConfigEntry 9 } bisyncRetries OBJECT-TYPE SYNTAX INTEGER (1..99) ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of retries (N2 value) before failing a CU. The default value for this field is 5." ::= { bisyncConfigEntry 10 } bisyncSlowpollTimer OBJECT-TYPE SYNTAX INTEGER (1..99) ACCESS read-only STATUS mandatory DESCRIPTION "The time to wait in seconds before attempting a slowpoll. The default value for this field is 30 seconds." ::= { bisyncConfigEntry 11 } bisyncSessTerm OBJECT-TYPE SYNTAX INTEGER { none (1), interventionReq (2), unformattedLogoff (3) } ACCESS read-only STATUS mandatory DESCRIPTION "The type of session termination used. Only applies to Host BSC ports." ::= { bisyncConfigEntry 12 } -- -- The Bisync Port Statistics Table: -- bisyncStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF BisyncStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of Bisync information." ::= { lineBisyncGroup 2 } bisyncStatsEntry OBJECT-TYPE SYNTAX BisyncStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry consisting of port information for a particular Bisync port." INDEX { bisyncStatsPortIndex } ::= { bisyncStatsTable 1 } BisyncStatsEntry ::= SEQUENCE { bisyncStatsPortIndex INTEGER, bisyncPortType INTEGER, bisyncInOctets Counter, bisyncOutOctets Counter, bisyncOverruns Counter, bisyncCRCErrors Counter, bisyncRcvTimeout Counter, bisyncXmtTimeout Counter } bisyncStatsPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number that uniquely identifies this Bisync port. Current supported numbers are 1-4." ::= { bisyncStatsEntry 1 } bisyncPortType OBJECT-TYPE SYNTAX INTEGER { hbsc-type(1), tbsc-type(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The port type. TBSC (Terminal Bisync) ports emulate a Host and poll the downstream controllers). HBSC ports (Host Bisync) ports emulate a line with Terminal Controllers (PUs) and respond to polls from the Host or upstream PU." ::= { bisyncStatsEntry 2 } bisyncInOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of bytes received." ::= { bisyncStatsEntry 3 } bisyncOutOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of bytes sent." ::= { bisyncStatsEntry 4 } bisyncOverruns OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of receiver overruns." ::= { bisyncStatsEntry 5 } bisyncCRCErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of receive frame CRC errors." ::= { bisyncStatsEntry 6 } bisyncRcvTimeout OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of receive timeout." ::= { bisyncStatsEntry 7 } bisyncXmtTimeout OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of transmit timeout." ::= { bisyncStatsEntry 8 } -- -- The Frame Relay Port Level Group -- -- -- The Frame Relay Configuration Table: -- frameRelayConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF FrameRelayConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of Sync product Frame Relay information." ::= { lineFrameRelayGroup 1 } frameRelayConfigEntry OBJECT-TYPE SYNTAX FrameRelayConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry consisting of port information for a particular Sync product Frame Relay port." INDEX { frameRelayConfigPortIndex } ::= { frameRelayConfigTable 1 } FrameRelayConfigEntry ::= SEQUENCE { frameRelayConfigPortIndex INTEGER, frameRelayPortType INTEGER, frameRelayInitState INTEGER, frameRelayClocking INTEGER, frameRelaySpeed INTEGER, frameRelayLocalManagementProtocol INTEGER, frameRelayLinkPollingTimer INTEGER, frameRelayFullStatusPollingCount INTEGER, frameRelayT1Timer INTEGER, frameRelayT2Timer INTEGER, frameRelayTiTimer INTEGER, frameRelayRxWindowSize INTEGER, frameRelayTxWindowSize INTEGER, frameRelayMaxRetries INTEGER, frameRelayNAUName DisplayString, frameRelayVirtualMACAddress PhysAddress, frameRelayVirtualRingNumber INTEGER, frameRelayVirtualBridgeNumber INTEGER, frameRelayIPAddress IpAddress, frameRelayNetworkMask IpAddress, frameRelayDefaultGatewayAddress IpAddress } frameRelayConfigPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number that uniquely identifies this port." ::= { frameRelayConfigEntry 1 } frameRelayPortType OBJECT-TYPE SYNTAX INTEGER { frame-relay-type(19) } ACCESS read-only STATUS mandatory DESCRIPTION "The Frame Relay port type." ::= { frameRelayConfigEntry 2 } frameRelayInitState OBJECT-TYPE SYNTAX INTEGER { in-service(1), out-of-service(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The initial state of the Frame Relay port. If configured for 'in-service', then the Frame Relay port will be brougt up automatically when the unit is powered up. If configured for 'out-of-service', then the Frame Relay port must be manually enabled by operator intervention (i.e. enable command must be sent). The default value is 'enabled'." ::= { frameRelayConfigEntry 3 } frameRelayClocking OBJECT-TYPE SYNTAX INTEGER { external(1), internal(2), x21-external(3), x21-internal(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Clocking source for this port. Setting 'internal' will cause the port to emulate a physical DCE, and setting external will cause the port to emulate a physical DTE. X21 External and Internal are used (with the proper external adapter) to support X.21 Leased Line operation for RS-422/RS-530 (25 pin balanced) interfaces. X21 operation is not supported for boards that operate RS-232 or V.35. The default value for this field is 'external'." ::= { frameRelayConfigEntry 4 } frameRelaySpeed OBJECT-TYPE SYNTAX INTEGER -- { -- speed1200(12), -- speed2000(20), -- speed2400(24), -- speed3600(36), -- speed4800(48), -- speed7200(72), -- speed9600(96), -- speed14400(144), -- speed19200(192), -- speed28800(288), -- speed48000(480), -- speed56000(560), -- speed64000(640), -- speed128000(1280), -- speed256000(2560) -- } ACCESS read-only STATUS mandatory DESCRIPTION "The ports speed in bits per second. The default value is 9600 bits per second. Speeds higher than 19200 are not supported on RS-232 port Sync products (must be V.35 or RS-422)." ::= { frameRelayConfigEntry 5 } frameRelayLocalManagementProtocol OBJECT-TYPE SYNTAX INTEGER { annexD(1), lmi(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The ports management protocol type. Annex D = ANSI T1.617 Annex D LMI = Frame Relay Manufacturers LMI The default value is Annex D." ::= { frameRelayConfigEntry 6 } frameRelayLinkPollingTimer OBJECT-TYPE SYNTAX INTEGER (5..30) ACCESS read-only STATUS mandatory DESCRIPTION "Measured in seconds, intervals of 5 T391 - Annex D nT1 - LMI The default value for this field is 5 seconds." ::= { frameRelayConfigEntry 7 } frameRelayFullStatusPollingCount OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "The number of polls that a full status poll is issued. N391 - Annex D nT1 - LMI The default value for this field is 6." ::= { frameRelayConfigEntry 8 } frameRelayT1Timer OBJECT-TYPE SYNTAX INTEGER (1..25) ACCESS read-only STATUS mandatory DESCRIPTION "The default LLC T1 timer value in seconds. T1 should be greater than T2 and less than Ti. Currently supported values are 1 to 25 seconds. The default value for this field is 3 seconds." ::= { frameRelayConfigEntry 9 } frameRelayT2Timer OBJECT-TYPE SYNTAX INTEGER (0..50) ACCESS read-only STATUS mandatory DESCRIPTION "The default LLC T2 timer value in tenths of seconds. If configured for 0 then the T2 timer is disabled and an RR frame will be sent for every I frame received. Current supported values are 0 and 2-50. T2 should be less than T1. The default value for this field is 0 (disabled)." ::= { frameRelayConfigEntry 10 } frameRelayTiTimer OBJECT-TYPE SYNTAX INTEGER (2..50) ACCESS read-only STATUS mandatory DESCRIPTION "The default LLC Ti (inactivity) timer value in seconds. Ti should be greater than T1. Currently supported values are 2 to 50 seconds. The default value for this field is 30 seconds." ::= { frameRelayConfigEntry 11 } frameRelayRxWindowSize OBJECT-TYPE SYNTAX INTEGER (1..7) ACCESS read-only STATUS mandatory DESCRIPTION "The default LLC receive window (N3) size. Note that this is not the same receive window as defined in IEEE 802.2 LLC. This is N3 which is the number of I frames received before an RR frame is sent (defined as N3 in IEEE 802.2 LLC). Current allowable values are 1-7. The default value for this field is 7." ::= { frameRelayConfigEntry 12 } frameRelayTxWindowSize OBJECT-TYPE SYNTAX INTEGER (1..7) ACCESS read-only STATUS mandatory DESCRIPTION "The defalut LLC transmit window size. Current allowable values are 1-7. The default value for this field is 7." ::= { frameRelayConfigEntry 13 } frameRelayMaxRetries OBJECT-TYPE SYNTAX INTEGER (1..20) ACCESS read-only STATUS mandatory DESCRIPTION "The default LLC maximum number of retries (N2 value). The default value for this field is 15." ::= { frameRelayConfigEntry 14 } frameRelayNAUName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) ACCESS read-only STATUS mandatory DESCRIPTION "The NAU name of this port. The default value for this field is all blank (filled with ASCII space 0x20 characters)." ::= { frameRelayConfigEntry 15 } frameRelayVirtualMACAddress OBJECT-TYPE SYNTAX PhysAddress ACCESS read-only STATUS mandatory DESCRIPTION "The F/R WAN is treated as a token ring. This address is used for communication with other bridges in the network." ::= { frameRelayConfigEntry 16 } frameRelayVirtualRingNumber OBJECT-TYPE SYNTAX INTEGER (1..4095) ACCESS read-only STATUS mandatory DESCRIPTION "The F/R WAN is treated as a token ring. This is the ring number for the F/R network to which the port is attached. It must be a unique ring number in the network. The default value for this field is 1." ::= { frameRelayConfigEntry 17 } frameRelayVirtualBridgeNumber OBJECT-TYPE SYNTAX INTEGER (1..15) ACCESS read-only STATUS mandatory DESCRIPTION "The F/R WAN is treated as a token ring. This variable only has significance if more than 1 F/R port is configured. The default value for this field is 1." ::= { frameRelayConfigEntry 18 } frameRelayIPAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "This is the IP Address of this interface." ::= { frameRelayConfigEntry 19 } frameRelayNetworkMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "This is the network mask to be used on this interface." ::= { frameRelayConfigEntry 20 } frameRelayDefaultGatewayAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Default gateway address to be used when sending responses on this interface." ::= { frameRelayConfigEntry 21 } -- -- The Frame Relay Port Statistics Table: -- frameRelayStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF FrameRelayStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of Frame Relay information." ::= { lineFrameRelayGroup 2 } frameRelayStatsEntry OBJECT-TYPE SYNTAX FrameRelayStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry consisting of port information for a particular Frame Relay port." INDEX { frameRelayStatsPortIndex } ::= { frameRelayStatsTable 1 } FrameRelayStatsEntry ::= SEQUENCE { frameRelayStatsPortIndex INTEGER, frameRelayInOctets Counter, frameRelayOutOctets Counter, frameRelaySampleDuration INTEGER, frameRelayOverruns Counter, frameRelayCRCErrors Counter, frameRelayRecvAborts Counter } frameRelayStatsPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number that uniquely identifies this Frame Relay port." ::= { frameRelayStatsEntry 1 } frameRelayInOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of bytes received inclusive of all valid bytes in the frame relay frame except for the CRC field (frame relay header included)." ::= { frameRelayStatsEntry 2 } frameRelayOutOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of bytes transmitted inclusive of all bytes in the frame relay frame except for the CRC field (frame relay header included)." ::= { frameRelayStatsEntry 3 } frameRelaySampleDuration OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The sample duration in seconds for Frame Relay Statistics for this port." ::= { frameRelayStatsEntry 4 } frameRelayOverruns OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of receiver overruns." ::= { frameRelayStatsEntry 5 } frameRelayCRCErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of received CRC errors." ::= { frameRelayStatsEntry 6 } frameRelayRecvAborts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of received frame aborts received." ::= { frameRelayStatsEntry 7 } -- -- The PU Control Group -- puControlTable OBJECT-TYPE SYNTAX SEQUENCE OF PuControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table for controlling lines and obtaining information." ::= { puControlGroup 1 } puControlEntry OBJECT-TYPE SYNTAX PuControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry consisting of PU information for a particular port." INDEX { puControlLineIndex, puControlPUAddress } ::= { puControlTable 1 } PuControlEntry ::= SEQUENCE { puControlLineIndex INTEGER, puControlPUAddress OCTET STRING, puStatus INTEGER, puConnectionStatus INTEGER, puLastClearCode OCTET STRING, puControlFailureCode OCTET STRING, puControlNAUName DisplayString, puConnectionAttemptCount Counter } puControlLineIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number that has a given PU." ::= { puControlEntry 1 } puControlPUAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "The PU address in the range of 0x01 to 0xfe." ::= { puControlEntry 2 } puStatus OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2), failed(3), restart(4), enable-all(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The status of the PU. To change status of a port an enable, enable all or disable may be set. Valid Return status are enable(d), disable(d), or failed. Commands: An enable command will attempt to bring up the PU. An enable all command will attempt to bring up the line and any lower layer entities (e.g. PUs). A disable command will disable the PU. Status: Enable(d) indicates the PU is enabled and running. Disable(d) indicates the PU has been disabled. Failed indicates the PU is enabled and not Running." ::= { puControlEntry 3 } puConnectionStatus OBJECT-TYPE SYNTAX INTEGER { connected(1), not-connected(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The status of the LLC type 2 Connection for this SDLC PU." ::= { puControlEntry 4 } puLastClearCode OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2)) ACCESS read-only STATUS mandatory DESCRIPTION "A two octet field indicating the Last Clearing Cause and Diagnostic Field of the last failed connection attempt (a.k.a. call attempt) or active connection (a.k.a. session). For LLC type 2 connections the first octet (cause) is always 0. The second octet (diagnostic) indicates the reason for the last connection failure. The second octet is set to 0 when a sucessful call has been placed, or if no call has ever been placed (e.g. PU never came up). If the second octet is non-zero then it indicates the reason for the connection attempt failure. See User's Guide for information" ::= { puControlEntry 5 } puControlFailureCode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (2)) ACCESS read-only STATUS mandatory DESCRIPTION "This entry contains the failure codes if the associated PU is in the failed state." ::= { puControlEntry 6 } puControlNAUName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) ACCESS read-only STATUS mandatory DESCRIPTION "The NAU name of this PU. The default value for this field is all blank (filled with ASCII space 0x20 characters)." ::= { puControlEntry 7 } puConnectionAttemptCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of connection attempts performed. This count is set to zero at startup, and after every loss of an estabished session." ::= { puControlEntry 8 } -- -- The PU Configuration Group -- -- The PU Configuration Group contains information on the lines' -- configured PUs. sdlcPuConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF SdlcPuConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of PU entries." ::= { puSDLCGroup 1 } sdlcPuConfigEntry OBJECT-TYPE SYNTAX SdlcPuConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry contains information about a given PU. The entry is indexed by the port number and the PU number." INDEX { sdlcPuConfigLineIndex, sdlcPuConfigAddress } ::= { sdlcPuConfigTable 1 } SdlcPuConfigEntry ::= SEQUENCE { sdlcPuConfigLineIndex INTEGER, sdlcPuConfigAddress OCTET STRING, sdlcPuNAUName DisplayString, sdlcPuInitialState INTEGER, sdlcPuXID OCTET STRING, sdlcPuType INTEGER, sdlcPuGroupPollAddress OCTET STRING, sdlcPuConnectionID OCTET STRING, sdlcPuMAXOUT INTEGER, sdlcPuConnectType INTEGER } sdlcPuConfigLineIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number for which the line (CU)is configured (first level)." ::= { sdlcPuConfigEntry 1 } sdlcPuConfigAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "The PU address in the range of 0x00 to 0xfe." ::= { sdlcPuConfigEntry 2 } sdlcPuNAUName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) ACCESS read-only STATUS mandatory DESCRIPTION "The NAU name of this PU. The default value for this field is all blank (filled with ASCII space 0x20 characters)." ::= { sdlcPuConfigEntry 3 } sdlcPuInitialState OBJECT-TYPE SYNTAX INTEGER { in-service(1), out-of-service(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The initial state of the PU. If configured for 'in-service', then the SDLC PU will be brougt up automattically when the unit is powered up. If configured for 'out-of-service', the the SDLC PU must be manually enabled by operator intervention (i.e. enable command must be sent). The default value is 'in-service'." ::= { sdlcPuConfigEntry 4 } sdlcPuXID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "The XID value for this PU. The XID is used to identify the PU during the LLC connection process to the remote Host or Gateway. If the field is configured to 0 then the unit will solicit the XID from the downstream PU and send the XID data received from SDLC to the XID data sent for the LLC connection process. If not sent to 0, then the unit will insert the data configured in the LLC sent to the host during the LLC connection process on behalf of the CU. For incoming LLC connections on Sync Research products this field is parsed to route the connection to the proper PU. The default value for this field is all zeroes (solicit XID from PU)." ::= { sdlcPuConfigEntry 5 } sdlcPuType OBJECT-TYPE SYNTAX INTEGER { type1(1), type2(2), type2-1(3), type4(4), type5(5) } ACCESS read-only STATUS mandatory DESCRIPTION "The SNA PU type. 1 = PU type 1 2 = PU type 2 3 = PU type 2.1 4 = PU type 4 (not supported, reserved) 5 = PU type 5 (not supported, reserved) This parameter defaults to a value of 2." ::= { sdlcPuConfigEntry 6 } sdlcPuGroupPollAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "The PU's group address in the range of 0x01 to 0xfe. setting this value to 0 will disable the group poll feature for polling this and other PUs in a group. The default value for this field is 0." ::= { sdlcPuConfigEntry 7 } sdlcPuConnectionID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2)) ACCESS read-only STATUS mandatory DESCRIPTION "This entry defines the Connection ID to a corresponding entry in the mapping table. The default value for this field is all zeroes." ::= { sdlcPuConfigEntry 8 } sdlcPuMAXOUT OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This entry defines the maximum number of outstanding I frames that the PU will allow. This field is applicable to TSDLC only." ::= { sdlcPuConfigEntry 9 } sdlcPuConnectType OBJECT-TYPE SYNTAX INTEGER { answer(1), originate(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The SNA PU Connection type." ::= { sdlcPuConfigEntry 10 } -- -- The SDLC PU Statistics Table: -- -- The SDLC PU Statisctics table contains statistical information on the -- lines' configured PUs. sdlcPuStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF SdlcPuStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of PU statistics entries." ::= { puSDLCGroup 2 } sdlcPuStatsEntry OBJECT-TYPE SYNTAX SdlcPuStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry contains information about a given PU. The entry is indexed by the port number and the PU number." INDEX { sdlcPuStatsLineIndex, sdlcPuStatsAddress } ::= { sdlcPuStatsTable 1 } SdlcPuStatsEntry ::= SEQUENCE { sdlcPuStatsLineIndex INTEGER, sdlcPuStatsAddress OCTET STRING, sdlcPuInIFrames Counter, sdlcPuOutIFrames Counter, sdlcPuInRRFrames Counter, sdlcPuOutRRFrames Counter, sdlcPuInRNRFrames Counter, sdlcPuOutRNRFrames Counter, sdlcPuInXIDFrames Counter, sdlcPuOutXIDFrames Counter, sdlcPuInTESTFrames Counter, sdlcPuOutTESTFrames Counter, sdlcPuInSNRMFrames Counter, sdlcPuOutSNRMFrames Counter, sdlcPuInDISCFrames Counter, sdlcPuOutDISCFrames Counter, sdlcPuInDMFrames Counter, sdlcPuOutDMFrames Counter, sdlcPuInUAFrames Counter, sdlcPuOutUAFrames Counter, sdlcPuInFRMRFrames Counter, sdlcPuOutFRMRFrames Counter, sdlcPuInRDFrames Counter, sdlcPuOutRDFrames Counter, sdlcPuInUIFrames Counter, sdlcPuOutUIFrames Counter, sdlcPuReTxIFrames Counter, sdlcPuPollResponseTimeouts Counter } sdlcPuStatsLineIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number for which PU is configured on." ::= { sdlcPuStatsEntry 1 } sdlcPuStatsAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "The PU address in the range of 0x00 to 0xfe." ::= { sdlcPuStatsEntry 2 } sdlcPuInIFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of I frames received on this PU." ::= { sdlcPuStatsEntry 3 } sdlcPuOutIFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of I frames trasnmitted on this PU." ::= { sdlcPuStatsEntry 4 } sdlcPuInRRFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of RR frames received on this PU." ::= { sdlcPuStatsEntry 5 } sdlcPuOutRRFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of RR frames transmitted on this PU." ::= { sdlcPuStatsEntry 6 } sdlcPuInRNRFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of RNR frames received on this PU." ::= { sdlcPuStatsEntry 7 } sdlcPuOutRNRFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of RNR frames transmitted on this PU." ::= { sdlcPuStatsEntry 8 } sdlcPuInXIDFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of XID frames received on this PU." ::= { sdlcPuStatsEntry 9 } sdlcPuOutXIDFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of XID frames transmitted on this PU." ::= { sdlcPuStatsEntry 10 } sdlcPuInTESTFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of TEST frames received on this PU." ::= { sdlcPuStatsEntry 11 } sdlcPuOutTESTFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of TEST frames transmitted on this PU." ::= { sdlcPuStatsEntry 12 } sdlcPuInSNRMFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of SNRM frames received on this PU." ::= { sdlcPuStatsEntry 13 } sdlcPuOutSNRMFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of SNRM frames transmitted on this PU." ::= { sdlcPuStatsEntry 14 } sdlcPuInDISCFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of DISC frames received on this PU." ::= { sdlcPuStatsEntry 15 } sdlcPuOutDISCFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of DISC frames transmitted on this PU." ::= { sdlcPuStatsEntry 16 } sdlcPuInDMFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of DM frames received on this PU." ::= { sdlcPuStatsEntry 17 } sdlcPuOutDMFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of DM frames transmitted on this PU." ::= { sdlcPuStatsEntry 18 } sdlcPuInUAFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of UA frames received on this PU." ::= { sdlcPuStatsEntry 19 } sdlcPuOutUAFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of UA frames transmitted on this PU." ::= { sdlcPuStatsEntry 20 } sdlcPuInFRMRFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of FRMR frames received on this PU." ::= { sdlcPuStatsEntry 21 } sdlcPuOutFRMRFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of FRMR frames transmitted on this PU." ::= { sdlcPuStatsEntry 22 } sdlcPuInRDFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of RD frames received on this PU." ::= { sdlcPuStatsEntry 23 } sdlcPuOutRDFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of RD frames transmitted on this PU." ::= { sdlcPuStatsEntry 24 } sdlcPuInUIFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of UI frames received on this PU." ::= { sdlcPuStatsEntry 25 } sdlcPuOutUIFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of UI frames transmitted on this PU." ::= { sdlcPuStatsEntry 26 } sdlcPuReTxIFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of re-transmitted I frames on this PU." ::= { sdlcPuStatsEntry 27 } sdlcPuPollResponseTimeouts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of PU Poll Response timeouts for this PU." ::= { sdlcPuStatsEntry 28 } -- -- The Bisync PU Group -- -- The Bisync PU Configuration Table: -- bisyncPuConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF BisyncPuConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of Bisync CU entries." ::= { puBisyncGroup 1 } bisyncPuConfigEntry OBJECT-TYPE SYNTAX BisyncPuConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry contains information about a given PU. The entry is indexed by the port number and the PU number." INDEX { bisyncPuConfigLineIndex, bisyncPuConfigAddress } ::= { bisyncPuConfigTable 1 } BisyncPuConfigEntry ::= SEQUENCE { bisyncPuConfigLineIndex INTEGER, bisyncPuConfigAddress OCTET STRING, bisyncPuNAUName DisplayString, bisyncPuInitialState INTEGER, bisyncPuXID OCTET STRING, bisyncPuTargetHostType INTEGER, bisyncPuMaxData INTEGER, bisyncPuConnectionID OCTET STRING, bisyncPuConnectType INTEGER } bisyncPuConfigLineIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number for which PU is configured on." ::= { bisyncPuConfigEntry 1 } bisyncPuConfigAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "The PU address in the range of 0x00 to 0xfe." ::= { bisyncPuConfigEntry 2 } bisyncPuNAUName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) ACCESS read-only STATUS mandatory DESCRIPTION "The NAU name of this PU. The default value for this field is all blank (filled with ASCII space 0x20 characters)." ::= { bisyncPuConfigEntry 3 } bisyncPuInitialState OBJECT-TYPE SYNTAX INTEGER { in-service(1), out-of-service(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The initial state of the PU. If configured for 'in-service', then the SDLC PU will be brougt up automattically when the unit is powered up. If configured for 'out-of-service', the the SDLC PU must be manually enabled by operator intervention (i.e. enable command must be sent). The default value is 'in-service'." ::= { bisyncPuConfigEntry 4 } bisyncPuXID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "The XID value for this PU. The XID is used to identify the PU during the LLC connection process to the remote Host or Gateway. The unit will insert the data configured in the LLC XID sent to the host during the LLC connection process on behalf of the CU. For bisync control units, this field is required as bisync cannot solicit an XID. For incoming LLC connections on Sync Research products this field is parsed to route the connection to the proper PU. The default value for this field is all zeroes." ::= { bisyncPuConfigEntry 5 } bisyncPuTargetHostType OBJECT-TYPE SYNTAX INTEGER { sna-host-type(1), bisync-host-type(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The Target Host type. 1 = SNA host type 2 = Bisync host type This field specifies the target host type for TBSC and is applicable to BSC-to-SNA conversion only. This parameter defaults to a value of 2." ::= { bisyncPuConfigEntry 6 } bisyncPuMaxData OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This entry defines the SNA frame size which is the sum of SNA data and SNA header. This value must match the MAXData configured for SNA host and is applicable to BSC-to-SNA conversion only. The default value is 521. The valid range is 265, 521, 777, 1033, 1289." ::= { bisyncPuConfigEntry 7 } bisyncPuConnectionID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2)) ACCESS read-only STATUS mandatory DESCRIPTION "This entry defines the Connection ID to a corresponding entry in the mapping table. The default value for this field is all zeroes." ::= { bisyncPuConfigEntry 8 } bisyncPuConnectType OBJECT-TYPE SYNTAX INTEGER { answer(1), originate(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The Bisync PU Connection type." ::= { bisyncPuConfigEntry 9 } -- -- The Bisync PU Statistics Table: -- -- The Bisync PU Statisctics table contains statistical information on -- the lines' configured PUs. bisyncPuStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF BisyncPuStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of PU statistics entries." ::= { puBisyncGroup 2 } bisyncPuStatsEntry OBJECT-TYPE SYNTAX BisyncPuStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry contains information about a given PU. The entry is indexed by the port number and the PU number." INDEX { bisyncPuStatsLineIndex, bisyncPuStatsAddress } ::= { bisyncPuStatsTable 1 } BisyncPuStatsEntry ::= SEQUENCE { bisyncPuStatsLineIndex INTEGER, bisyncPuStatsAddress OCTET STRING, bisyncPuInTransactions Counter, bisyncPuOutTransactions Counter, bisyncPuSlowPolls Counter, bisyncPuPolls Counter } bisyncPuStatsLineIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number for which PU is configured on." ::= { bisyncPuStatsEntry 1 } bisyncPuStatsAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "The PU address in the range of 0x00 to 0xfe." ::= { bisyncPuStatsEntry 2 } bisyncPuInTransactions OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of PU Poll Response timeouts for this PU." ::= { bisyncPuStatsEntry 3 } bisyncPuOutTransactions OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of PU Poll Response timeouts for this PU." ::= { bisyncPuStatsEntry 4 } bisyncPuSlowPolls OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of PU slow polls for this PU." ::= { bisyncPuStatsEntry 5 } bisyncPuPolls OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of PU Polls for this PU." ::= { bisyncPuStatsEntry 6 } -- -- The Mapping PU Group -- -- The Mapping PU Configuration Table contains mapping information -- on the lines' configured PUs. mappingPuConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF MappingPuConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of PU mapping entries." ::= { puMappingGroup 1 } mappingPuConfigEntry OBJECT-TYPE SYNTAX MappingPuConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry contains information about a given mapping PU. Each entry includes MAC/SAP information for a source PU and a similar information for the partner (mapped) PU. Depending upon whether the PU is LAN-attached, SDLC-attached or Frame Relay-attached, one or more fields may not apply. Some fields, for example, mappingPuNAU, mappingPuXID, mappingPuConnectID are common to both end points. The entry is indexed by the port number and the PU number." INDEX { mappingPuConfigLineIndex, mappingPuConfigAddress } ::= { mappingPuConfigTable 1 } MappingPuConfigEntry ::= SEQUENCE { mappingPuConfigLineIndex INTEGER, mappingPuConfigAddress OCTET STRING, mappingPuSourceSAP OCTET STRING, mappingPuDestinationSAP OCTET STRING, mappingPuDestinationMAC PhysAddress, mappingPuPartnerConfigLineIndex INTEGER, mappingPuPartnerConfigAddress OCTET STRING, mappingPuPartnerSourceSAP OCTET STRING, mappingPuPartnerDestSAP OCTET STRING, mappingPuPartnerDestMAC PhysAddress, mappingPuNAU DisplayString, mappingPuConnectID OCTET STRING, mappingPuXID OCTET STRING, mappingPuDirectDLCI OCTET STRING } mappingPuConfigLineIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number for which PU is associated with. Port number 99 is a special value which is used to indicate NetView PU." ::= { mappingPuConfigEntry 1 } mappingPuConfigAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "The PU address in the range of 0x01 to 0xfe." ::= { mappingPuConfigEntry 2 } mappingPuSourceSAP OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "The LLC source SAP value for this PU. Typically the source SAP will vary for each PU. This is due to the fact that most Sync products are configured to always call the same remote Token-Ring Host or Gateway for all connections configured. This means that all the Destination SAP (usually set to 4) and Destination MAC addresses are the same, so the Source SAP field must be set to a unique value in order to uniquely identify the LLC connection to the Host. (SNA does not allow multiplexing of PUs on one LLC connection. Each PU must have its own LLC Type 2 connection.) This field must be set to a range between 04 and E8 hexadecimal and it must be evenly divisible by 4 (802.2 LLC rules for user assigned SAPs). This field is not applicable in all cases, if not it returns a dummy value. This parameter defaults to a value of 4." ::= { mappingPuConfigEntry 3 } mappingPuDestinationSAP OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "The LLC Destination SAP value for this PU. For SNA typically the destination is almost always SAP 4. However both Host Front Ends (e.g. 3745) or Gateways (e.g. 3174) allow SAPs to be configured for any value betwee 0x04 and 0xEC as long as the SAP ID is a user assignable individual SAP ID (any value evenly divisable by 4). This field is not applicable to all cases. If not it returns a dummy value. This parameter defaults to a value of 4." ::= { mappingPuConfigEntry 4 } mappingPuDestinationMAC OBJECT-TYPE SYNTAX PhysAddress ACCESS read-only STATUS mandatory DESCRIPTION "The LAN Destination MAC address used in the LLC Type 2 connection for this PU. The Token-Ring format for this field is a 6 octet (48 bit) field represented in IEEE 802.5 format where the first bit transmitted is the most significant bit. The destination MAC must also be an 'Individual' address. Therefore valid addresses are between 000000000001 and 7FFFFFFFFFFF (an address of all zeroes is not supported). The Ethernet format for this field is a 6 octet (48 bit) field represented in IEEE 802.3 format where the first bit transmitted is the least significant bit. The destination MAC must also be an 'Individual' address. Therefore valid addresses must start with the least significant bit equal to 0. In other words, the first two digits must be in the set of 0x00, 0x02, 0x04, ... 0xFE (an address of all 12 digits equal to zeroes is not supported). This field is not applicable to all cases. If not it returns a dummy value." ::= { mappingPuConfigEntry 5 } mappingPuPartnerConfigLineIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number for the partner PU associated with source PU. Port number 99 is a special value which is used to indicate NetView PU." ::= { mappingPuConfigEntry 6 } mappingPuPartnerConfigAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "The PU address of the partner PU in the range of 0x01 to 0xfe." ::= { mappingPuConfigEntry 7 } mappingPuPartnerSourceSAP OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "The LLC source SAP value for a partner PU. Typically the source SAP will vary for each PU. This is due to the fact that most Sync products are configured to always call the same remote Token-Ring Host or Gateway for all connections configured. This means that all the Destination SAP (usually set to 4) and Destination MAC addresses are the same, so the Source SAP field must be set to a unique value in order to uniquely identify the LLC connection to the Host. (SNA does not allow multiplexing of PUs on one LLC connection. Each PU must have its own LLC Type 2 connection.) This field must be set to a range between 04 and E8 hexadecimal and it must be evenly divisible by 4 (802.2 LLC rules for user assigned SAPs). This field is not applicable in all cases, if not it returns a dummy value. This parameter defaults to a value of 4." ::= { mappingPuConfigEntry 8 } mappingPuPartnerDestSAP OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "The LLC Destination SAP value for the partner PU. For SNA typically the destination is almost always SAP 4. However both Host Front Ends (e.g. 3745) or Gateways (e.g. 3174) allow SAPs to be configured for any value betwee 0x04 and 0xEC as long as the SAP ID is a user assignable individual SAP ID (any value evenly divisable by 4). This field is not applicable to all cases. It returns a dummy value. This parameter defaults to a value of 4." ::= { mappingPuConfigEntry 9 } mappingPuPartnerDestMAC OBJECT-TYPE SYNTAX PhysAddress ACCESS read-only STATUS mandatory DESCRIPTION "The LAN Destination MAC address used in the LLC Type 2 connection for the partner PU. The Token-Ring format for this field is a 6 octet (48 bit) field represented in IEEE 802.5 format where the first bit transmitted is the most significant bit. The destination MAC must also be an 'Individual' address. Therefore valid addresses are between 000000000001 and 7FFFFFFFFFFF (an address of all zeroes is not supported). The Ethernet format for this field is a 6 octet (48 bit) field represented in IEEE 802.3 format where the first bit transmitted is the least significant bit. The destination MAC must also be an 'Individual' address. Therefore valid addresses must start with the least significant bit equal to 0. In other words, the first two digits must be in the set of 0x00, 0x02, 0x04, ... 0xFE (an address of all 12 digits equal to zeroes is not supported). This field is not applicable to all cases. If not it returns a dummy value." ::= { mappingPuConfigEntry 10 } mappingPuNAU OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) ACCESS read-only STATUS mandatory DESCRIPTION "The NAU Name. The NAU name is same for both the source PU and the partner PU. It represents one physical PU in a network." ::= { mappingPuConfigEntry 11 } mappingPuConnectID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2)) ACCESS read-only STATUS mandatory DESCRIPTION "The connection ID. This must match a connection ID of an access line PU or another mapping PU Connection ID. The connnection ID is 0 if there is no mapping." ::= { mappingPuConfigEntry 12 } mappingPuXID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "The XID value for this PU. The XID is used to identify the PU during the LLC connection process to the remote Host or Gateway. For incoming LLC connections on Sync Research products this field is parsed to route the connection to the proper PU. The XID is same for both the source PU and the partner PU. It represents one physical PU in a network. The default value for this field is all zeroes." ::= { mappingPuConfigEntry 13 } mappingPuDirectDLCI OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "The Frame Relay DLCI used in the LLC Type 2 connection for this PU. The Frame Relay format for this field is a 2 octet (16 bit) field represented in BCD format. A valid DLCI would be from 0001 to 1023 (0000 is reserved for AnnexD management. 1023 is reserved for LMI mangement.). This value is applicable to Frame Relay-attached PU only. The field corresponds to a source port or a partner port depending upon whether the source PU is a Frame Relay-attached PU or the partner PU is Frame Relay-attached PU. For Frame Relay-attached PU if this value is not configured, 0 is returned." ::= { mappingPuConfigEntry 14 } -- -- The Device Control Group -- deviceControlTable OBJECT-TYPE SYNTAX SEQUENCE OF DeviceControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table for controlling devices and obtaining information." ::= { deviceControlGroup 1 } deviceControlEntry OBJECT-TYPE SYNTAX DeviceControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry consisting of device information for a particular device." INDEX { deviceControlIndex, deviceControlCUIndex, deviceControlAddress } ::= { deviceControlTable 1 } DeviceControlEntry ::= SEQUENCE { deviceControlIndex INTEGER, deviceControlCUIndex INTEGER, deviceControlAddress OCTET STRING, deviceStatus INTEGER, deviceControlFailureCode OCTET STRING } deviceControlIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number that uniquely identifies this device." ::= { deviceControlEntry 1 } deviceControlCUIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The CU index for this device." ::= { deviceControlEntry 2 } deviceControlAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "The device address." ::= { deviceControlEntry 3 } deviceStatus OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2), failed(3), restart(4), enable-all(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The status of the device. To change (write) status of a device, enable, disable, restart or enable all may be set. Valid Return (read) status are enable(d), disable(d), or failed (d). Commands: An enable command will attempt to bring up the device. An enable all command will perform the same function as enable, since there are no sub elements on a device. A disable command will disable the device. Status: Enable(d) indicates the device is enabled and running. Disable(d) indicates the device has been disabled. Failed (d) indicates the device is enabled and not Running." ::= { deviceControlEntry 4 } deviceControlFailureCode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (2)) ACCESS read-only STATUS mandatory DESCRIPTION "This entry contains the failure codes if the associated device is in the failed state." ::= { deviceControlEntry 5 } -- -- The Device Configuration Group -- -- The Device Configuration Group contains information on the lines' -- configured Devices. -- -- The Device Configuration Table deviceConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF DeviceConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of device entries." ::= { deviceBSCGroup 1 } deviceConfigEntry OBJECT-TYPE SYNTAX DeviceConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry contains information about a given device. The entry is indexed by the port number, CU index, and device." INDEX { deviceConfigLineIndex, deviceConfigCUIndex, deviceConfigAddress } ::= { deviceConfigTable 1 } DeviceConfigEntry ::= SEQUENCE { deviceConfigLineIndex INTEGER, deviceConfigCUIndex INTEGER, deviceConfigAddress OCTET STRING, deviceConfigType INTEGER } deviceConfigLineIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number for which the line (CU)is configured (line level)." ::= { deviceConfigEntry 1 } deviceConfigCUIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The CU index which this device is configured on (CU level)." ::= { deviceConfigEntry 2 } deviceConfigAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "The device address in the legal range of BSC poll addresses (device level)." ::= { deviceConfigEntry 3 } deviceConfigType OBJECT-TYPE SYNTAX INTEGER { crt (1), printer (2) } ACCESS read-only STATUS mandatory DESCRIPTION "The device type. The default value is crt." ::= { deviceConfigEntry 4 } -- -- The Device Statistics Table -- deviceStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF DeviceStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of device statistics information." ::= { deviceBSCGroup 2 } deviceStatsEntry OBJECT-TYPE SYNTAX DeviceStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry contains information about a given device. The entry is indexed by the port number, CU index, and device." INDEX { bscDeviceLineIndex, bscDeviceCUIndex, bscDeviceAddress } ::= { deviceStatsTable 1 } DeviceStatsEntry ::= SEQUENCE { bscDeviceLineIndex INTEGER, bscDeviceCUIndex INTEGER, bscDeviceAddress OCTET STRING, bscDeviceInTransactions Counter, bscDeviceOutTransactions Counter, bscDeviceSumCount Counter, bscDeviceResponseDelaySum Counter, bscDeviceResponseDelaySqSum Counter } bscDeviceLineIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number for which the line (CU)is configured (line level)." ::= { deviceStatsEntry 1 } bscDeviceCUIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The CU index which this device is configured on (CU level)." ::= { deviceStatsEntry 2 } bscDeviceAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "The device address in the legal range of BSC poll addresses (device level)." ::= { deviceStatsEntry 3 } bscDeviceInTransactions OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of device receiving transactions." ::= { deviceStatsEntry 4 } bscDeviceOutTransactions OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of device transmitting transactions." ::= { deviceStatsEntry 5 } bscDeviceSumCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The device sum count." ::= { deviceStatsEntry 6 } bscDeviceResponseDelaySum OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The device sum count." ::= { deviceStatsEntry 7 } bscDeviceResponseDelaySqSum OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The device sum count." ::= { deviceStatsEntry 8 } -- -- Sync Research TRAP MIB -- -- This MIB was jointly developed by Sync Research, Cabletron Systems, -- and Avatar Consultants. -- -- Last Modification: -- 06/27/93 Suketu Pandya, Sync Research, Version 1.0 -- New version. This version obsoletes previous version 0.1 -- -- This MIB module uses the extended TRAP-TYPE macro as -- defined in RFC 1215. configChanged TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber, configId } DESCRIPTION "This trap indicates that the configuration of the unit has been changed." ::= 800 configError TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber, lastInstallErrCode } DESCRIPTION "This trap indicates that the activation of configuration of the unit has resulted in an error. New configuration has not been successfully activated." ::= 801 dumpExists TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber, dumpFileName } DESCRIPTION "This trap indicates that a memory core dump exists." ::= 802 dumpArchived TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber } DESCRIPTION "This trap indicates that the memory dump file has been archived." ::= 803 lineStatusChanged TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber, lineStatus, lineControlFailureCode, linePhysicalIndex } DESCRIPTION "This trap indicates that the indicated Line or Port has changed state. It has either been enabled, failed or disabled." ::= 804 lanStatusChanged TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber, lanStatus, lanControlFailureCode } DESCRIPTION "This trap indicates that the indicated LAN Port has changed state. It has either been enabled, failed or disabled." ::= 805 lineQuality TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber, lineQualityFrameCount, lineQualityCRCErrors, lineQualityAborts, linePhysicalIndex } DESCRIPTION " " ::= 806 puStatusChanged TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber, puStatus, puControlFailureCode, linePhysicalIndex, puControlPUAddress } DESCRIPTION "This trap indicates that the indicated PU has changed state. It has either been enabled, failed or disabled." ::= 807 puConnectionStatusChanged TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber, puConnectionStatus, puLastClearCode } DESCRIPTION "Note this trap is obsolete. This trap indicates that the indicated PU has changed connection state. Its connection has either been established, disconnected, or rejected." ::= 808 netviewConnectionStatusChanged TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber, netviewConnectionStatus, netviewLastClearCode } DESCRIPTION "Note this trap is obsolete. This trap indicates that the NetView PU has changed connection state. Its connection has either been established, disconnected, or rejected." ::= 809 netviewAltConnectionStatusChanged TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber, netviewAltConnectionStatus, netviewAltLastClearCode } DESCRIPTION "Note this trap is obsolete. This trap indicates that the Alternate NetView PU has changed connection state. Its connection has either been established, disconnected, or rejected." ::= 810 puConnectionStatusUp TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber, linePhysicalIndex, puControlPUAddress } DESCRIPTION "This trap indicates that the indicated PU has changed connection state. Its connection had been established." ::= 811 puConnectionStatusDown TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber, puLastClearCode, linePhysicalIndex, puControlPUAddress } DESCRIPTION "This trap indicates that the indicated PU has changed connection state. Its connection has been disconnected. If the indicated PU is not in session, the trap is generated only if the clear code is different from the puLastClearCode." ::= 812 netviewConnectionStatusUp TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber } DESCRIPTION "This trap indicates that the indicated NetView PU has changed connection state. Its connection has been established." ::= 813 netviewConnectionStatusDown TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber, netviewLastClearCode } DESCRIPTION "This trap indicates that the indicated NetView PU has changed connection state. Its connection had been disconnected. If the indicated PU is not in session, the trap is generated only if the clear code is different from the netviewLastClearCode." ::= 814 netviewAltConnectionStatusUp TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber } DESCRIPTION "This trap indicates that the indicated Alternate NetView PU has changed connection state. Its connection has been established." ::= 815 netviewAltConnectionStatusDown TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber, netviewAltLastClearCode } DESCRIPTION "This trap indicates that the indicated Alternate NetView PU has changed connection state. Its connection had been disconnected. If the indicated PU is not in session, the trap is generated only if the clear code is different from the netviewAltLastClearCode." ::= 816 END