-- SECTION 1: Top Level Definitions CENTILLION-BRIDGEGROUP-MIB DEFINITIONS ::= BEGIN -- Centillion Bridge Group MIB Release 2.0.0 -- Revision 03/20/96 -- Copyright 1994-96 Bay Networks, Inc. -- All rights reserved. -- This Bay Networks SNMP Management Information Base Specification -- (Specification) embodies Bay Networks' confidential and -- proprietary intellectual property. Bay Networks retains all -- title and ownership in the Specification, including any -- revisions. -- This Specification is supplied "AS IS," and Bay Networks makes -- no warranty, either express or implied, as to the use, -- operation, condition, or performance of the Specification. -- Imports IMPORTS OBJECT-TYPE FROM RFC-1212 StatusIndicator, sysConfig FROM CENTILLION-ROOT-MIB; -- Textual Conventions -- -- Centillion Networks switches support multiple bridging groups, -- which are identified by a unique bridge group identifier -- as specified by this textual convention: BridgeGroupId ::= INTEGER (1..32) -- Groups bridgeGroup OBJECT IDENTIFIER ::= { sysConfig 24 } -- SECTION 2: Bridge Group -- -- Centillion Networks switches allow a multiple number of bridge groups -- to be configured. The bridge configuration MIB allows a management -- application to perform configuration across any of the bridge groups. -- dot1dBaseGroupIdentifier OBJECT-TYPE SYNTAX BridgeGroupId ACCESS read-write STATUS mandatory DESCRIPTION "The bridge group identifier for which the standard bridging MIBS apply. Modifications of the bridge group through the standard bridging MIBs effect this bridge group only." ::= { bridgeGroup 1 } bridgeGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF BridgeGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A specific bridge group. A bridge group consists of a number of bridging ports running the same spanning tree protocol." ::= { bridgeGroup 2 } bridgeGroupEntry OBJECT-TYPE SYNTAX BridgeGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the bridge group table. Bridge groups are added by specifying a bridgeGroupIdentifier, bridgeGroupBaseType and a bridgeGroupSTPprotocol with a valid status. Entries may be deleted by specifying an entry with an invalid status." INDEX { bridgeGroupIdentifier } ::= { bridgeGroupTable 1 } BridgeGroupEntry ::= SEQUENCE { bridgeGroupIdentifier BridgeGroupId, bridgeGroupStatus StatusIndicator, bridgeGroupBaseType INTEGER, bridgeGroupStpProtocol INTEGER, bridgeGroupPortType INTEGER, bridgeGroupNextPortIndex INTEGER } bridgeGroupIdentifier OBJECT-TYPE SYNTAX BridgeGroupId ACCESS read-write STATUS mandatory DESCRIPTION "The unique bridge group identifier of this bridge group." ::= { bridgeGroupEntry 1 } bridgeGroupStatus OBJECT-TYPE SYNTAX StatusIndicator ACCESS read-write STATUS mandatory DESCRIPTION "The current status of the bridge group. Bridge groups may be added by specifiying a valid status, and removed by specifying an invalid status." ::= { bridgeGroupEntry 2 } bridgeGroupBaseType OBJECT-TYPE SYNTAX INTEGER { none(1), -- no bridging unknown(2), -- none of the following transparent-only(3), sourceroute-only(4), srt(5), translation(6) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the type of bridging this bridge is performing. A value of none implies that switching is performed between ports in this bridge group. A value of unknown implies that some unknown bridging rules are applied on the ports in this bridge group. Modifying the bridgeGroupBaseType requires a complete reset of the bridge group." ::= { bridgeGroupEntry 3 } bridgeGroupStpProtocol OBJECT-TYPE SYNTAX INTEGER { none(1), unknown(2), decLb100(3), ieee8021d(4), ibm(5) } ACCESS read-write STATUS mandatory DESCRIPTION "An indication of the version of the Spanning Tree Protocol is being run, if the value of bridgeGroupBaseType is not none. This field may be ignored if the bridgeGroupBaseType value is none." ::= { bridgeGroupEntry 4 } bridgeGroupPortType OBJECT-TYPE SYNTAX INTEGER { unknown(1), token-ring(2), ethernet(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the type of the bridge ports. This value may only be altered if there are no bridge ports currently in the bridge group. This value must be specified during bridge group creation." ::= { bridgeGroupEntry 5 } bridgeGroupNextPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of the next bridge port number which will be assigned by the switch. When adding bridge ports briding mode, the specified bridgeGroupPortIndex must match this value." ::= { bridgeGroupEntry 6 } -- -- The bridgeGroupPort Table -- bridgeGroupPortTable OBJECT-TYPE SYNTAX SEQUENCE OF BridgeGroupPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table that contains information about each port that is associated with this bridge group." ::= { bridgeGroup 3 } bridgeGroupPortEntry OBJECT-TYPE SYNTAX BridgeGroupPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of information for each port of the bridge group. Ports may be added by specifying a valid port index, and a valid status. Entries are deleted by setting the corresponsing object to invalid." INDEX { bridgeGroupPortGroupId, bridgeGroupPortIndex } ::= { bridgeGroupPortTable 1 } BridgeGroupPortEntry ::= SEQUENCE { bridgeGroupPortGroupId BridgeGroupId, bridgeGroupPortIndex INTEGER, bridgeGroupPortStatus StatusIndicator, bridgeGroupPortIfIndex INTEGER, bridgeGroupPortSpanMode INTEGER } bridgeGroupPortGroupId OBJECT-TYPE SYNTAX BridgeGroupId ACCESS read-only STATUS mandatory DESCRIPTION "The bridge group identifier to which this port belongs." ::= { bridgeGroupPortEntry 1 } bridgeGroupPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of the instance of the dot1dBasePort object, defined in the Bridge MIB, for the bridge port corresponding to this port." ::= { bridgeGroupPortEntry 2 } bridgeGroupPortStatus OBJECT-TYPE SYNTAX StatusIndicator ACCESS read-only STATUS mandatory DESCRIPTION "The current status of the bridge port entry. Bridge ports is added or deleted when a virtual segment port is added to or deleted from a virtual segment." ::= { bridgeGroupPortEntry 3 } bridgeGroupPortIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of the instance of the ifIndex object, defined in MIB-II, for the interface corresponding to this port. Bridge ports are added by specifying the ifIndex instance for the bridge port." ::= { bridgeGroupPortEntry 4 } bridgeGroupPortSpanMode OBJECT-TYPE SYNTAX INTEGER { auto-span(1), disabled(2), forced(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines how this port behaves when presented with a Spanning Tree Explorer frame. The value 'disabled(2)' indicates that the port will not accept or send Spanning Tree Explorer packets; any STE packets received will be silently discarded. The value 'forced(3)' indicates the port will always accept and propagate Spanning Tree Explorer frames. This allows a manually configured Spanning Tree for this class of packet to be configured. Note that unlike transparent bridging, this is not catastrophic to the network if there are loops. The value 'auto-span(1)' can only be returned by a bridge that both implements the Spanning Tree Protocol and has use of the protocol enabled on this port. The behavior of the port for Spanning Tree Explorer frames is determined by the state of dot1dStpPortState. If the port is in the 'forwarding' state, the frame will be accepted or propagated. Otherwise, it will be silently discarded." ::= { bridgeGroupPortEntry 5 } END