-- automatically generated by mosy 7.1 #289 (emptech), do not edit! IF-MIB DEFINITIONS ::= BEGIN IMPORTS -- AutonomousType -- FROM RFC1316-MIB TruthValue FROM OSPF-MIB TRAP-TYPE FROM RFC-1215 -- PhysAddress, DisplayString -- FROM RFC1213-MIB OBJECT-TYPE FROM RFC-1212 TimeTicks, Gauge, Counter FROM RFC1155-SMI -- mib-2 -- interfaces, mib-2, snmp, -- mib-2, snmp -- interfaces, mib-2, snmp, DisplayString, PhysAddress mib-2, snmp, DisplayString, PhysAddress FROM RFC1213-MIB IANAifType FROM IANAifType-MIB -- TestAndIncr, RowStatus, PhysAddress, DisplayString -- RowStatus, PhysAddress, DisplayString RowStatus FROM STOP-GAP-V2; -- FROM SNMPv2-TC; -- snmpTraps -- FROM SNMPv2-MIB -- Counter64 -- FROM SNMPv2-SMI; ifMIB OBJECT IDENTIFIER ::= { mib-2 31 } ifMIBObjects OBJECT IDENTIFIER ::= { ifMIB 1 } -- Added because ignoring interfaces group defined in rfc1213 interfaces OBJECT IDENTIFIER ::= { mib-2 2 } -- snmp OBJECT IDENTIFIER ::= { mib-2 11 } -- EOH (END OF HACK) -- Removed because the objects that used it was removed. --OwnerString ::= -- OCTET STRING L_InterfaceIndex ::= INTEGER (-2147483648..2147483647) ifNumber OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The number of network interfaces (regardless of their current state) present on this system." ::= { interfaces 1 } ifTable OBJECT-TYPE SYNTAX SEQUENCE OF IfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of interface entries. The number of entries is given by the value of ifNumber." ::= { interfaces 2 } ifEntry OBJECT-TYPE SYNTAX IfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing management information applicable to a particular interface." INDEX { ifIndex } ::= { ifTable 1 } IfEntry ::= SEQUENCE { ifIndex L_InterfaceIndex, ifDescr DisplayString, ifType IANAifType, ifMtu -- INTEGER (-2147483648..2147483647), INTEGER, ifSpeed Gauge, ifPhysAddress PhysAddress, ifAdminStatus INTEGER, ifOperStatus INTEGER, ifLastChange TimeTicks, ifInOctets Counter, ifInUcastPkts Counter, ifInNUcastPkts Counter, ifInDiscards Counter, ifInErrors Counter, ifInUnknownProtos Counter, ifOutOctets Counter, ifOutUcastPkts Counter, ifOutNUcastPkts Counter, ifOutDiscards Counter, ifOutErrors Counter, ifOutQLen Gauge, ifSpecific OBJECT IDENTIFIER } ifIndex OBJECT-TYPE SYNTAX L_InterfaceIndex ACCESS read-only STATUS mandatory DESCRIPTION "A unique value, greater than zero, for each interface. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization." ::= { ifEntry 1 } ifDescr OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "A textual string containing information about the interface. This string should include the name of the manufacturer, the product name and the version of the interface hardware/software." ::= { ifEntry 2 } ifType OBJECT-TYPE SYNTAX IANAifType ACCESS read-only STATUS mandatory DESCRIPTION "The type of interface. Additional values for ifType are assigned by the Internet Assigned Numbers Authority (IANA), through updating the syntax of the IANAifType textual convention." ::= { ifEntry 3 } ifMtu OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The size of the largest packet which can be sent/received on the interface, specified in octets. For interfaces that are used for transmitting network datagrams, this is the size of the largest network datagram that can be sent on the interface." ::= { ifEntry 4 } ifSpeed OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "An estimate of the interface's current bandwidth in bits per second. For interfaces which do not vary in bandwidth or for those where no accurate estimation can be made, this object should contain the nominal bandwidth. If the bandwidth of the interface is greater than the maximum value reportable by this object then this object should report its maximum value (4,294,967,295) and ifHighSpeed must be used to report the interace's speed. For a sub-layer which has no concept of bandwidth, this object should be zero." ::= { ifEntry 5 } ifPhysAddress OBJECT-TYPE SYNTAX PhysAddress ACCESS read-only STATUS mandatory DESCRIPTION "The interface's address at its protocol sub-layer. The interface's media-specific MIB must define the bit and byte ordering and format of the value contained by this object. For interfaces which do not have such an address (e.g., a serial line), this object should contain an octet string of zero length." ::= { ifEntry 6 } ifAdminStatus OBJECT-TYPE SYNTAX INTEGER { up(1), down(2), testing(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The desired state of the interface. The testing(3) state indicates that no operational packets can be passed. When a managed system initializes, all interfaces start with ifAdminStatus in the down(2) state. As a result of either explicit management action or per configuration information retained by the managed system, ifAdminStatus is then changed to either the up(1) or testing(3) states (or remains in the down(2) state)." ::= { ifEntry 7 } ifOperStatus OBJECT-TYPE SYNTAX INTEGER { up(1), down(2), testing(3), unknown(4), dormant(5) } ACCESS read-only STATUS mandatory DESCRIPTION "The current operational state of the interface. The testing(3) state indicates that no operational packets can be passed. If ifAdminStatus is down(2) then ifOperStatus should be down(2). If ifAdminStatus is changed to up(1) then ifOperStatus should change to up(1) if the interface is ready to transmit and receive network traffic; it should change to dormant(5) if the interface is waiting for external actions (such as a serial line waiting for an incomming connection); it should remain in the down(2) state if and only if there is a fault that prevents if from going to the up(1) state." ::= { ifEntry 8 } ifLastChange OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The value of sysUpTime at the time the interface entered its current operational state. If the current state was entered prior to the last re-initialization of the local network management subsystem, then this object contains a zero value." ::= { ifEntry 9 } ifInOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of octets received on the interface, including framing characters." ::= { ifEntry 10 } ifInUcastPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets, delivered by this sub-layer to a higher (sub-)layer, which were not addressed to a multicast or broadcast address at this sub-layer." ::= { ifEntry 11 } ifInNUcastPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS deprecated DESCRIPTION "The number of packets, delivered by this sub-layer to a higher (sub-)layer, which were addressed to a multicast or broadcast address at this sub-layer. This object is deprecated in favour of ifInMulticastPkts and ifInBroadcastPkts." ::= { ifEntry 12 } ifInDiscards OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of inbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space." ::= { ifEntry 13 } ifInErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "For packet-oriented interfaces, the number of inbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of inbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol." ::= { ifEntry 14 } ifInUnknownProtos OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "For packet-oriented interfaces, the number of packets received via the interface which were discarded because of an unknown or unsupported protocol. For character-oriented or fixed-length interfaces which support protocol multiplexing the number of transmission units received via the interface which were discarded because of an unknown or unsupported protocol. For any interface which does not support protocol multiplexing, this counter will always be 0." ::= { ifEntry 15 } ifOutOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of octets transmitted out of the interface, including framing characters." ::= { ifEntry 16 } ifOutUcastPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of packets that higher-level protocols requested be transmitted, and which were not addressed to a multicast or broadcast address at this sub-layer, including those that were discarded or not sent." ::= { ifEntry 17 } ifOutNUcastPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS deprecated DESCRIPTION "The total number of packets that higher-level protocols requested be transmitted, and which were addressed to a multicast or broadcast address at this sub-layer, including those that were discarded or not sent. This object is deprecated in favour of ifOutMulticastPkts and ifOutBroadcastPkts." ::= { ifEntry 18 } ifOutDiscards OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of outbound packets which were chosen to be discarded even though no errors had been detected to prevent their being transmitted. One possible reason for discarding such a packet could be to free up buffer space." ::= { ifEntry 19 } ifOutErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "For packet-oriented interfaces, the number of outbound packets that could not be transmitted because of errors. For character-oriented or fixed-length interfaces, the number of outbound transmission units that could not be transmitted because of errors." ::= { ifEntry 20 } ifOutQLen OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS deprecated DESCRIPTION "The length of the output packet queue (in packets)." ::= { ifEntry 21 } ifSpecific OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS deprecated DESCRIPTION "A reference to MIB definitions specific to the particular media being used to realize the interface. It is recommended that this value point to an instance of a MIB object in the media-specific MIB, i.e., that this object have the semantics associated with the InstancePointer textual convention defined in RFC 1443. In fact, it is recommended that the media- specific MIB specify what value ifSpecific should/can take for values of ifType. If no MIB definitions specific to the particular media are available, the value should be set to the OBJECT IDENTIFIER { 0 0 }." ::= { ifEntry 22 } -- -- Extension to the interface table -- -- This table replaces the ifExtnsTable table. -- ifXTable OBJECT-TYPE SYNTAX SEQUENCE OF IfXEntry -- MAX-ACCESS not-accessible ACCESS not-accessible -- STATUS current STATUS mandatory DESCRIPTION "A list of interface entries. The number of entries is given by the value of ifNumber. This table contains additional objects for the interface table." ::= { ifMIBObjects 1 } ifXEntry OBJECT-TYPE SYNTAX IfXEntry -- MAX-ACCESS not-accessible ACCESS not-accessible -- STATUS current STATUS mandatory DESCRIPTION "An entry containing additional management information applicable to a particular interface." -- AUGMENTS { ifEntry } INDEX { ifIndex } ::= { ifXTable 1 } IfXEntry ::= SEQUENCE { ifName DisplayString, ifInMulticastPkts Counter, ifInBroadcastPkts Counter, ifOutMulticastPkts Counter, ifOutBroadcastPkts Counter, ifLinkUpDownTrapEnable INTEGER, ifHighSpeed Gauge, ifPromiscuousMode TruthValue, ifConnectorPresent TruthValue } ifName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The textual name of the interface. The value of this object should be the name of the interface as assigned by the local device and should be suitable for use in commands entered at the device's `console'. This might be a text name, such as `le0' or a simple port number, such as `1', depending on the interface naming syntax of the device. If several entries in the ifTable together represent a single interface as named by the device, then each will have the same value of ifName. If there is no local name, or this object is otherwise not applicable, then this object contains a 0-length string." ::= { ifXEntry 1 } ifInMulticastPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets, delivered by this sub-layer to a higher (sub-)layer, which were addressed to a multicast address at this sub-layer. For a MAC layer protocol, this includes both Group and Functional addresses." ::= { ifXEntry 2 } ifInBroadcastPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets, delivered by this sub-layer to a higher (sub-)layer, which were addressed to a broadcast address at this sub-layer." ::= { ifXEntry 3 } ifOutMulticastPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of packets that higher-level protocols requested be transmitted, and which were addressed to a multicast address at this sub-layer, including those that were discarded or not sent. For a MAC layer protocol, this includes both Group and Functional addresses." ::= { ifXEntry 4 } ifOutBroadcastPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of packets that higher-level protocols requested be transmitted, and which were addressed to a broadcast address at this sub-layer, including those that were discarded or not sent." ::= { ifXEntry 5 } ifLinkUpDownTrapEnable OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates whether linkUp/linkDown traps should be generated for this interface. By default, this object should have the value enabled(1) for interfaces which do not operate on 'top' of any other interface (as defined in the ifStackTable), and disabled(2) otherwise." ::= { ifXEntry 14 } ifHighSpeed OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "An estimate of the interface's current bandwidth in units of 1,000,000 bits per second. If this object reports a value of `n' then the speed of the interface is somewhere in the range of `n-500,000' to `n+499,999'. For interfaces which do not vary in bandwidth or for those where no accurate estimation can be made, this object should contain the nominal bandwidth. For a sub-layer which has no concept of bandwidth, this object should be zero." ::= { ifXEntry 15 } ifPromiscuousMode OBJECT-TYPE SYNTAX TruthValue ACCESS read-write STATUS mandatory DESCRIPTION "This object has a value of false(2) if this interface only accepts packets/frames that are addressed to this station. This object has a value of true(1) when the station accepts all packets/frames transmitted on the media. The value true(1) is only legal on certain types of media. If legal, setting this object to a value of true(1) may require the interface to be reset before becoming effective. The value of ifPromiscuousMode does not affect the reception of broadcast and multicast packets/frames by the interface." ::= { ifXEntry 16 } ifConnectorPresent OBJECT-TYPE SYNTAX TruthValue ACCESS read-only STATUS mandatory DESCRIPTION "This object has the value 'true(1)' if the interface sublayer has a physical connector and the value 'false(2)' otherwise." ::= { ifXEntry 17 } ifStackTable OBJECT-TYPE SYNTAX SEQUENCE OF IfStackEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table containing information on the relationships between the multiple sub-layers of network interfaces. In particular, it contains information on which sub- layers run 'on top of' which other sub-layers. Each sub-layer corresponds to a conceptual row in the ifTable." ::= { ifMIBObjects 2 } ifStackEntry OBJECT-TYPE SYNTAX IfStackEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Information on a particular relationship between two sub-layers, specifying that one sub-layer runs on 'top' of the other sub-layer. Each sub-layer corresponds to a conceptual row in the ifTable." INDEX { ifStackHigherLayer, ifStackLowerLayer } ::= { ifStackTable 1 } IfStackEntry ::= SEQUENCE { ifStackHigherLayer INTEGER, -- INTEGER (-2147483648..2147483647), ifStackLowerLayer INTEGER, -- INTEGER (-2147483648..2147483647), ifStackStatus RowStatus } ifStackHigherLayer OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) -- ACCESS not-accessible ACCESS read-only STATUS mandatory DESCRIPTION "The value of ifIndex corresponding to the higher sub-layer of the relationship, i.e., the sub-layer which runs on 'top' of the sub-layer identified by the corresponding instance of ifStackLowerLayer. If there is no higher sub-layer (below the internetwork layer), then this object has the value 0." ::= { ifStackEntry 1 } ifStackLowerLayer OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) -- ACCESS not-accessible ACCESS read-only STATUS mandatory DESCRIPTION "The value of ifIndex corresponding to the lower sub- layer of the relationship, i.e., the sub-layer which runs 'below' the sub-layer identified by the corresponding instance of ifStackHigherLayer. If there is no lower sub-layer, then this object has the value 0." ::= { ifStackEntry 2 } ifStackStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "The status of the relationship between two sub- layers. Changing the value of this object from 'active' to 'notInService' or 'destroy' will likely have consequences up and down the interface stack. Thus, write access to this object is likely to be inappropriate for some types of interfaces, and many implementations will choose not to support write- access for any type of interface." ::= { ifStackEntry 3 } ifRcvAddressTable OBJECT-TYPE SYNTAX SEQUENCE OF IfRcvAddressEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains an entry for each address (broadcast, multicast, or uni-cast) for which the system will receive packets/frames on a particular interface, except as follows: - for an interface operating in promiscuous mode, entries are only required for those addresses for which the system would receive frames were it not operating in promiscuous mode. - for 802.5 functional addresses, only one entry is required, for the address which has the functional address bit ANDed with the bit mask of all functional addresses for which the interface will accept frames." ::= { ifMIBObjects 4 } ifRcvAddressEntry OBJECT-TYPE SYNTAX IfRcvAddressEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of objects identifying an address for which the system will accept packets/frames on the particular interface identified by the index value ifIndex." INDEX { ifIndex, ifRcvAddressAddress } ::= { ifRcvAddressTable 1 } IfRcvAddressEntry ::= SEQUENCE { ifRcvAddressAddress PhysAddress, ifRcvAddressStatus RowStatus, ifRcvAddressType INTEGER } ifRcvAddressAddress OBJECT-TYPE SYNTAX PhysAddress -- ACCESS read-write ACCESS read-only STATUS mandatory DESCRIPTION "An address for which the system will accept packets/frames on this entry's interface." ::= { ifRcvAddressEntry 1 } ifRcvAddressStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to create and delete rows in the ifRcvAddressTable." ::= { ifRcvAddressEntry 2 } ifRcvAddressType OBJECT-TYPE SYNTAX INTEGER { other(1), volatile(2), nonVolatile(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This object has the value nonVolatile(3) for those entries in the table which are valid and will not be deleted by the next restart of the managed system. Entries having the value volatile(2) are valid and exist, but have not been saved, so that will not exist after the next restart of the managed system. Entries having the value other(1) are valid and exist but are not classified as to whether they will continue to exist after the next restart." DEFVAL { volatile } ::= { ifRcvAddressEntry 3 } linkDown TRAP-TYPE ENTERPRISE snmp VARIABLES { ifIndex, ifAdminStatus, ifOperStatus } DESCRIPTION "A linkDown trap signifies that the SNMPv2 entity, acting in an agent role, has detected that the ifOperStatus object for one of its communication links is about to transition into the down state." ::= 3 linkUp TRAP-TYPE ENTERPRISE snmp VARIABLES { ifIndex, ifAdminStatus, ifOperStatus } DESCRIPTION "A linkUp trap signifies that the SNMPv2 entity, acting in an agent role, has detected that the ifOperStatus object for one of its communication links has transitioned out of the down state." ::= 4 ifConformance OBJECT IDENTIFIER ::= { ifMIB 2 } ifGroups OBJECT IDENTIFIER ::= { ifConformance 1 } ifCompliances OBJECT IDENTIFIER ::= { ifConformance 2 } ifCompliance OBJECT IDENTIFIER ::= { ifCompliances 1 } ifGeneralGroup OBJECT IDENTIFIER ::= { ifGroups 1 } ifFixedLengthGroup OBJECT IDENTIFIER ::= { ifGroups 2 } ifHCFixedLengthGroup OBJECT IDENTIFIER ::= { ifGroups 3 } ifPacketGroup OBJECT IDENTIFIER ::= { ifGroups 4 } ifHCPacketGroup OBJECT IDENTIFIER ::= { ifGroups 5 } ifVHCPacketGroup OBJECT IDENTIFIER ::= { ifGroups 6 } ifRcvAddressGroup OBJECT IDENTIFIER ::= { ifGroups 7 } ifTestGroup OBJECT IDENTIFIER ::= { ifGroups 8 } ifStackGroup OBJECT IDENTIFIER ::= { ifGroups 9 } END