-- SECTION 1: Top Level Definitions SYNOPTICS-COMMON-TRAP-MIB DEFINITIONS ::= BEGIN -- Common Trap MIB Release 1.4.0 -- Revision 01/25/94 -- Copyright 1990-94 SynOptics Communications, Inc. -- All rights reserved. -- This SynOptics SNMP Management Information Base Specification -- (Specification) embodies SynOptics' confidential and -- proprietary intellectual property. SynOptics retains all -- title and ownership in the Specification, including any -- revisions. -- This Specification is supplied "AS IS," and SynOptics makes -- no warranty, either express or implied, as to the use, -- operation, condition, or performance of the Specification. IMPORTS TRAP-TYPE FROM RFC-1215 ipAdEntAddr, ifPhysAddress FROM RFC1213-MIB synoptics FROM SYNOPTICS-ROOT-MIB s3ChassisPsStatus, s3ChassisFanStatus, s3CommonBoardStatus, s3CommonBoardPsStatus, s3AgentMibLevel, s3AgentFeatureLevel, s3SlotModuleType, s3RedPsPrimaryConfig, s3RedPsSecondaryConfig, s3RedPsPlus5vCurrent, s3RedPsPlus12vCurrent, s3RedPsAmbientTempStatus, s3RedPsAmbientTemperature, s3RedPsDiodeStatus, s3SlotModuleId, s3SlotModuleMdaId, s3AgentFlashStatus FROM SYNOPTICS-COMMON-MIB; -- SECTION 2: SynOptics Common Trap Definitions chassisPowerSupplyFailure TRAP-TYPE ENTERPRISE synoptics VARIABLES { s3ChassisPsStatus } -- STATUS mandatory for all SynOptics agents DESCRIPTION "Concentrator power supply failure." ::= 0 -- 0x00 chassisFanFailure TRAP-TYPE ENTERPRISE synoptics VARIABLES { s3ChassisFanStatus } -- STATUS mandatory for all SynOptics agents DESCRIPTION "Concentrator fan failure." ::= 1 -- 0x01 boardLEDFailure TRAP-TYPE ENTERPRISE synoptics VARIABLES { s3CommonBoardStatus } -- STATUS mandatory for Token Ring agents -- and Ethernet 4.0 & ff -- for Enet, replaces boardFailure(2) DESCRIPTION "Board is on but LED is off." ::= 11 -- 0x0b boardPowerSupplyFailure TRAP-TYPE ENTERPRISE synoptics VARIABLES { s3CommonBoardPsStatus } -- STATUS mandatory for all Token Ring and -- Ethernet 4.0 & ff agents -- for Enet, replaces -- enetBoardPowerSupplyFailure(3) DESCRIPTION "Board power supply failure." ::= 27 -- 0x1b keyManagementFailure TRAP-TYPE ENTERPRISE synoptics VARIABLES { ipAdEntAddr, ifPhysAddress, s3AgentMibLevel, s3AgentFeatureLevel } -- STATUS mandatory for all SynOptics 4.0 & ff agents DESCRIPTION "NMM detects that its key doesn't match the configuration." ::= 35 -- 0x23 lattisSecureInitRequired TRAP-TYPE ENTERPRISE synoptics VARIABLES { s3SlotModuleType } -- STATUS mandatory for 331xS 4.1 & ff agents DESCRIPTION "This trap is sent by a 331xS Ethernet NMM+ when a LattisSecure Host Module needs initialization. The location of the module is indicated by the instance identifier part of the returned variable, and the value of the variable tells the board identity." ::= 46 -- 0x2e redPsPlus5vCurrentExceed TRAP-TYPE ENTERPRISE synoptics VARIABLES { s3RedPsPrimaryConfig, s3RedPsSecondaryConfig, s3RedPsPlus5vCurrent } -- STATUS mandatory in a 3000 chassis with 3100R for -- 4.1 & ff agents DESCRIPTION "This trap is sent when the current level on the +5 V supply exceeds the maximum recommended level: 1) 30 amps if at least one of the power supplies is a 3001. 2) 50 amps if both power supplies are 3002. Note: The agent reads the current level only when it restarts.Changes in the current level that occur while the agent is running will not be noticed. Thus, this trap can only be generated at the end of the restart sequence." ::= 47 -- 0x2f redPsPlus12vCurrentExceed TRAP-TYPE ENTERPRISE synoptics VARIABLES { s3RedPsPrimaryConfig, s3RedPsSecondaryConfig, s3RedPsPlus12vCurrent } -- STATUS mandatory in a 3000 chassis with 3100R for -- 4.1 & ff agents DESCRIPTION "This trap is sent when the current level on the +12 V supply exceeds the maximum recommended level of 15 amps for any set of power supplies. Note: The agent reads the current level only when it restarts. Changes in the current level that occur while the agent is running will not be noticed. Thus, this trap can only be generated at the end of the restart sequence." ::= 48 -- 0x30 redPsAmbientTempStatChg TRAP-TYPE ENTERPRISE synoptics VARIABLES { s3RedPsAmbientTempStatus, s3RedPsAmbientTemperature } -- STATUS mandatory in a 3000 chassis with 3100R for -- 4.1 & ff agents DESCRIPTION "This trap is sent whenever there is a change (in either direction) in the psAmbientTempStatus variable." ::= 49 -- 0x31 redPsSummingDiodeFailure TRAP-TYPE ENTERPRISE synoptics VARIABLES { s3RedPsDiodeStatus } -- STATUS mandatory in a 3000 chassis with 3100R for -- 4.1 & ff agents DESCRIPTION "This trap is sent whenever the reported status of either 3100R summing diode changes from 'Ok' to 'Fail'." ::= 50 -- 0x32 boardSwap TRAP-TYPE ENTERPRISE synoptics VARIABLES { s3SlotModuleId, s3SlotModuleType, s3SlotModuleMdaId } -- STATUS mandatory for 4.1 & ff agents DESCRIPTION "This trap is sent whenever a board is inserted or removed. The values returned are those before the action was taken. Thus, the value of s3SlotModuleType will be empty(1) when a board is inserted. The instance value for the variables is the slot number of the board. On receiving the trap, a manager should use a get request to find the current values of these variables." ::= 51 -- 0x33 flashUpdateFailure TRAP-TYPE ENTERPRISE synoptics VARIABLES { s3AgentFlashStatus } -- STATUS mandatory DESCRIPTION "This trap is sent whenever the agent failed to update the local image due to flash device failure." ::= 54 -- 0x36 -- new ones here ... END