-- OIDref derived MIB transcription. Original PDF: https://www.ite.org/ITEORG/assets/File/Standards/1201v4-0-0.pdf -- Publisher front matter and notices follow as comments. -- A Joint Standard of AASHTO, ITE, and NEMA -- -- -- -- -- NTCIP 1201 v4.0.0 -- -- -- National Transportation -- Communications for ITS Protocol -- Global Object (GO) Definitions -- -- -- Published June 2025 -- -- -- -- -- Published by: -- -- American Association of State Highway and Transportation Officials (AASHTO) -- 555 12th Street, N.W., Suite 1000 -- Washington, D.C. 20004 -- -- Institute of Transportation Engineers (ITE) -- 1627 I Street, N.W., Suite 550 -- Washington, D.C. 20006 -- -- National Electrical Manufacturers Association (NEMA) -- 1300 17th Street N, #900 -- Arlington, VA 22209 -- -- -- --  2025 AASHTO / ITE / NEMA. All rights reserved. -- -- -- NOTICES -- -- Copyright Notice -- -- © 1997, 1999, 2005, 2011, 2025 by the American Association of State Highway and Transportation -- Of f icials (AASHTO), the Institute of Transportation Engineers (ITE), and the National Electrical -- Manuf acturers Association (NEMA). All intellectual property rights, including, but not limited to, the rights -- of reproduction, translation, and display are reserved under the laws of the United States of America, the -- Universal Copyright Convention, the Berne Convention, and the International and Pan American -- Copyright Conventions. Except as licensed or permitted, you may not copy these materials without prior -- written permission f rom AASHTO, ITE, or NEMA. Use of these materials does not grant any rights of -- ownership or claim of copyright. -- -- Visit www.ntcip.org For additional copyright inf ormation, instructions on requesting reprints of excerpts, -- and requests f or reproduction d the beyond the permissions granted below, visit www.ntcip.org. -- -- PDF File License Agreement -- -- To the extent that these materials are distributed by AASHTO / ITE / NEMA in the f orm of an Adobe® -- Portable Document Format (PDF) electronic f ile (the PDF f ile), AASHTO / ITE / NEMA authorizes each -- registered user to view, download, copy, or print the f ile f rom the authorized website, subject to the terms -- and conditions of this license agreement: -- -- a) You may download one copy of the PDF f ile f or personal, noncommercial, and intraorganizational -- use only. -- b) Ownership of the PDF f ile is not transf erred to you; you are licensed to use the PDF f ile. -- c) You may make one additional electronic copy of the PDF f ile, such as to a secondary hard drive -- or CD. -- d) You agree not to copy, distribute, or transf er the PDF f ile f rom that media to any other electronic -- media or device. -- e) You may print one paper copy of the PDF f ile. -- f ) You may make one paper reproduction of the printed copy. -- g) Any permitted copies must retain the copyright notice and all proprietary notices. -- h) The PDF f ile license does not include (1) resale of the PDF f ile or copies, (2) republishing the -- content in compendiums or anthologies, (3) publishing excerpts in commercial publications or -- works f or hire, (4) editing or modif ication of the PDF f ile except those portions as permitted, (5) -- posting on network servers or distribution by e- mail or f rom electronic storage devices, and (6) -- translation to other languages or conversion to other electronic f ormats. -- i) Other use of the PDF f ile and printed copy requires express, prior written consent. -- -- -- Data Dictionary and MIB Distribution Permission -- -- To the extent that these materials are distributed by AASHTO / ITE / NEMA in the f orm of a Data -- Dictionary ("DD") or Management Inf ormation Base ("MIB"), AASHTO / ITE / NEMA extend the f ollowing -- permission: -- -- You may make or distribute unlimited copies, in part or f ull, of the DD or MIB, including copies f or -- commercial distribution, provided that: -- -- 1. Each copy you make or distribute includes the citation "From NTCIP 0000 [insert the standard -- number]. Copyright by AASHTO / ITE / NEMA. Used by permission." -- 2. The copies are not edited f rom the published version of this document. -- -- These materials are delivered "AS IS," without any warranties regarding their use or perf ormance. -- -- AASHTO / ITE / NEMA and their suppliers do not warrant the performance or results you may -- obtain by using these materials. AASHTO / ITE / NEMA and their suppliers make no warranties, -- express or implied, as to noninfringement of third-party rights, merchantability, or fitness for any -- particular purpose. In no event will AASHTO / ITE / NEMA or their suppliers be liable to you or any -- third party for any claim or for any consequential, incidental or special damages, including any -- lost profits or lost savings, arising from your reproduction or use of these materials, even if an -- AASHTO / ITE / NEMA representative has been advised of the possibility of such damages. -- -- Some states or jurisdictions do not allow the exclusion or limitation of incidental, consequential, or special -- damages, or the exclusion of implied warranties, so the above limitations may not apply to a given user. -- -- Use of these materials does not constitute an endorsement or af f iliation by or between AASHTO, ITE, or -- NEMA and the user, the user's company, or the products and services of the user's company. -- -- If the user is unwilling to accept the f oregoing restrictions, he or she should immediately return these -- materials. -- -- Content and Liability Disclaimer -- -- The inf ormation in this publication was considered technically sound by the consensus of persons -- engaged in the development and approval of the document at the time it was developed. However, -- consensus does not imply unanimous agreement. among every person participating in the development -- of this document. -- -- AASHTO, ITE, and NEMA standards and guideline publications, of which the document contained herein -- is one, are developed through a voluntary consensus standards development process. This process -- brings together volunteers and seeks out the views of persons who have an interest in the topic covered -- by this publication. While AASHTO, ITE, and NEMA administer the process and establish rules to -- promote f airness in the development of consensus, they do not write the document and they do not -- independently test, evaluate, or verif y the accuracy or completeness of any inf ormation or the soundness -- of any judgments contained in their standards and guideline publications. -- -- AASHTO, ITE, and NEMA disclaim liability f or any personal injury, property, or other damages of any -- nature whatsoever, whether special, indirect, consequential, or compensatory, directly or indirectly -- resulting f rom the publication, use of , application, or reliance on this document. AASHTO, ITE, and NEMA -- disclaim and make no guaranty or warranty, express or implied, as to the accuracy or completeness of -- any inf ormation published herein and disclaims and makes no warranty that the inf ormation in this -- document will f ulf ill any of your purposes or needs. AASHTO, ITE, and NEMA do not undertake to -- guarantee the perf ormance of any individual manuf acturer or seller's products or services by virtue of this -- standard or guide. -- -- In publishing and making this document available, AASHTO, ITE, and NEMA are not undertaking to -- render prof essional or other services f or or on behalf of any person or entity, nor are AASHTO, ITE, and -- NEMA undertaking to perf orm any duty owed by any person or entity to someone else. Anyone using this -- document should rely on his or her own independent judgment or, as appropriate, seek the advice of a -- competent prof essional in determining the exercise of reasonable care in any given circumstance. -- Inf ormation and other standards on the topic covered by this publication may be available f rom other -- sources, which the user may wish to consult f or additional views or inf ormation not covered by this -- publication. -- -- AASHTO, ITE, and NEMA have no power, nor do they undertake to police or enf orce compliance with the -- contents of this document. AASHTO, ITE, and NEMA do not certif y, test, or inspect products, designs, or -- -- installations f or saf ety or health purposes. Any certif ication or other statement of compliance with any -- health or saf ety-related inf ormation in this document shall not be attributable to AASHTO, ITE, or NEMA -- and is solely the responsibility of the certif ier or maker of the statement. -- -- Trademark Notice -- -- NTCIP is a trademark of AASHTO / ITE / NEMA. All other trademarks mentioned in this standard belong -- to their respective owners. -- -- -- NTCIP 1201 v4.0.0 -- Page i -- -- -- -- ACKNOWLEDGEMENTS -- -- NTCIP 1201 v04 was prepared by the NTCIP Base Standards and Prof iles Working Group (BSP2 WG), a -- subdivision of the Joint Committee on the NTCIP. This committee operates under a Memorandum of -- Understanding among the American Association of State Highway and Transportation Of f icials -- (AASHTO), the Institute of Transportation Engineers (ITE), and the National Electrical Manuf acturers -- Association (NEMA). The Joint Committee on the NTCIP consists of six representatives f rom each -- standards development organization (SDO) and provides guidance f or NTCIP development. -- -- When this document was prepared, the f ollowing individuals were members of BSP2 WG: -- -- 1. Doug Crawf ord (Chair) 8. Robert Lopes -- 2. Steve Bostrom 9. Alex Mousadi -- 3. Wolf gang Buckel 10. Satya Muthuswamy -- 4. Michael Forbis 11. Bob Rausch -- 5. Joe Gorman 12. Rodney Schilling -- 6. Terry Haukom 13. Shea Tomsin -- 7. Patrick Leung 14. Walt Townsend -- -- -- Other individuals providing input include the f ollowing: -- -- 1. Md Ashraf Ahmed 18. Stephane Lapierre -- 2. Justin Anderson 19. Christopher Lyons -- 3. Kingsley Azubike 20. Gary Molnar -- 4. Ralph Boaz 21. Keith Patton -- 5. Russ Brookshire 22. Mahesh Pawar -- 6. Patrick Chan 23. Frank Perry -- 7. Stan Chow 24. Nu Rosenbohm -- 8. Deborah Curtis 25. Jay Schultz -- 9. Dustin DeVoe 26. Kellen Shain -- 10. Brian Doherty 27. Douglas Tarico -- 11. Edward Fok 28. Nicola Tavares -- 12. Sai Kiran Golla 29. John Thai -- 13. Jacob Grivette 30. Andrew Valdez -- 14. Mohammad Iraki 31. Kenneth Vaughn -- 15. Haydar Issa 32. Sankeer Vulupala -- 16. Denver Kruse 33. Robert White -- 17. AJ Lahiri -- -- -- In addition to the many volunteer ef f orts, recognition is also given to those organizations that supported -- the ef f orts of BSP2 WG by providing comments and f unding, including the f ollowing: -- -- 1. U.S. Department of Transportation, Research and Innovative Technology Administration -- 2. U.S. Department of Transportation, Federal Highway Administration -- 3. AECOM -- 4. Applied Inf ormation -- 5. City of Anaheim, CA -- 6. Consensus Systems Technologies -- 7. Caltrans -- 8. Daktronics -- 9. Econolite Control Products, Inc. -- 10. Florida Department of Transportation -- -- -- -- © 2025 AASHTO / ITE / NEMA Do Not Copy Without Written Permission -- -- NTCIP 1201 v4.0.0 -- Page ii -- -- 11. Georgia DOT -- 12. Kapsch -- 13. KLD Engineering -- 14. Michigan DOT -- 15. Minnesota DOT -- 16. Nevada DOT -- 17. Noblis -- 18. Parsons -- 19. Pillar Consulting -- 20. Q-Free -- 21. Siemens ITS -- 22. Signalisation Ver-Mac, Inc. -- 23. TransCore -- 24. Transport Canada -- 25. Trevilon -- 26. Washington State DOT -- 27. WSP -- -- -- -- -- Do Not Copy Without Written Permission © 2025 AASHTO / ITE / NEMA NTCIP1201-RecMech DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-IDENTITY, OBJECT-TYPE, Integer32, Unsigned32, Opaque, zeroDotZero FROM SNMPv2-SMI -- RFC 2578 application FROM NTCIP8004-Transportation; recMech MODULE-IDENTITY LAST-UPDATED "20230701145436Z" ORGANIZATION "NTCIP BSP2 WG" CONTACT-INFO "name: NTCIP Coordinator email: ntcip@nema.org postal: National Electrical Manufacturers Association 1300 North 17th Street, Suite 1752 Rosslyn, Virginia 22209-3801" DESCRIPTION " This MIB defines the SMIv2 representation of the NTCIP1103v0352-recMech MIB, which was defined in NTCIP 1103. This MIB defines objects related to the recording mechanism functions that are found in devices. This MIB was deprecated in NTCIP 1201 v04 due to security issues in the structure of the MIB. The objects have been replaced by objects in the NTCIP1201v04-recMech MIB. *** All objects in this MIB have been deprecated. *** The recording mechanism class table is presented first to ease -- the readability of the standard. 1.3.6.1.4.1.1206.4.1.1.7.9" REVISION "20230701145436Z" DESCRIPTION "NTCIP 1201 v04 - Upgraded format to SMIv2 and deprecated all objects." REVISION "201612310000Z" DESCRIPTION "NTCIP 1103 v03 - Original version of this MIB." ::= { application 9 } maxRecClasses OBJECT-TYPE SYNTAX Integer32 (1..254) UNITS "RecClasses" MAX-ACCESS read-only STATUS deprecated DESCRIPTION " The object defines the number of rows in the recClassTable that this device supports. This is a static table. The recClassTable has been replaced with a dynamic table, which does not require an object indicating the maximum number of rows. 1.3.6.1.4.1.1206.4.1.1.7.9.1" ::= { recMech 1 } recClassTable OBJECT-TYPE SYNTAX SEQUENCE OF RecClassEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "This table is used to configure recording mechanism limits and recording table maintenance. static ISO26048-1-Recording.fdRecordingClassTable The replacement table is dynamic. 1.3.6.1.4.1.1206.4.1.1.7.9.2" ::= { recMech 2 } recClassEntry OBJECT-TYPE SYNTAX RecClassEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "This object defines a row in the Recording Mechanism Class Table ISO26048-1-Recording.fdRecordingClassEntry The replacement table has a dual index consisting of an owner and a name, both SnmpAdminStrings. The table also adds columns for StorageType and RowStatus. 1.3.6.1.4.1.1206.4.1.1.7.9.2.1" INDEX { recClassNumber } ::= { recClassTable 1 } RecClassEntry ::= SEQUENCE { recClassNumber Integer32, recClassLimit Integer32, recClassClearTime Unsigned32, recClassDescription OCTET STRING, recClassNumRecordings Integer32, recClassRecordingCounter Integer32} recClassNumber OBJECT-TYPE SYNTAX Integer32 (1..254) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This is a class value that is to be configured. ISO26048-1-Recording.fdRecordingClassName The replacement object is an SnmpAdminString. 1.3.6.1.4.1.1206.4.1.1.7.9.2.1.1" ::= { recClassEntry 1 } recClassLimit OBJECT-TYPE SYNTAX Integer32 (0..254) UNITS "recordings" MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This object specifies the maximum number of recordings of the associated class to store in the device. Once the limit is reached, the oldest recording of the matching class (based on recordingTriggerTime) is overwritten by any new recording of the same class. If the value of this object is set to a number smaller than the current number of rows within this class in the recRecordingTable, then the oldest entries shall be lost/deleted. The sum of all recording mechanism class limits shall not exceed the maxRecRecordings object; if a SET operation to this object causes the sum of recClassLimit objects to exceed maxRecRecordings, then the agent shall respond with a genErr. The recording cannot be logged if the recClass has an recClassLimit of zero (0). ISO26048-1-Recording.fdRecordingClassSizeLimit The replacement object defines a maximum size in octets rather than the number of recordings. 1.3.6.1.4.1.1206.4.1.1.7.9.2.1.2" ::= { recClassEntry 2 } recClassClearTime OBJECT-TYPE SYNTAX Unsigned32 UNITS "seconds" MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This object is used to clear multiple recordings from the recRecordingTable. All completed recordings of this class that have a recRecordingTriggerTime equal to or less than this object shall be cleared from the recRecordingTable. If this object has a value greater than the current value of globalTime, it shall prevent the triggering of any recordings of this class. ISO26048-1-Recording.fdRecordingClassClearDate & recMechV2ClassClearTime The SMIv1 syntax for this object was Counter; however, by convention, an SNMPv1 Counter is not writable and SNMPv3 prohibits set operations. The syntax SMIv2 syntax for this object has been updated to Unsigned32 to avoid this conflict. The superseding objects provide a date/time pair. 1.3.6.1.4.1.1206.4.1.1.7.9.2.1.3" DEFVAL { 0 } ::= { recClassEntry 3 } recClassDescription OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This object specifies a description of the class in ASCII characters. ISO26048-1-Recording.fdRecordingClassDescription The replacement object uses a syntax of SnmpAdminString to clearly indicate that this should be readable text in any language. 1.3.6.1.4.1.1206.4.1.1.7.9.2.1.4" ::= { recClassEntry 4 } recClassNumRecordings OBJECT-TYPE SYNTAX Integer32 (0..255) UNITS "recordings" MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The number of recordings for this class that currently exist in the recRecordingTable. ISO26048-1-Recording.fdRecordingClassNumRecordings 1.3.6.1.4.1.1206.4.1.1.7.9.2.1.5" ::= { recClassEntry 5 } recClassRecordingCounter OBJECT-TYPE SYNTAX Integer32 (0..65535) UNITS "recordings" MAX-ACCESS read-only STATUS deprecated DESCRIPTION " This object is a counter that gets incremented every time a recording occurs for this class; it shall initialize to zero at power up. The value shall roll over each time it exceeds the maximum of 65535. ISO26048-1-Recording.fdRecordingClassRecordingCtr The replacement object has a syntax of ZeroBasedCounter32. 1.3.6.1.4.1.1206.4.1.1.7.9.2.1.6" ::= { recClassEntry 6 } maxRecConfigs OBJECT-TYPE SYNTAX Integer32 (1..65534) UNITS "RecordType" MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The number of rows that exist in the static recMechV2RecordingConfig table for this device. The recMechV2RecordingConfigTable has been replaced with a dynamic table, which does not require an object indicating the maximum number of rows. 1.3.6.1.4.1.1206.4.1.1.7.9.3" ::= { recMech 3 } recMinSamplePeriod OBJECT-TYPE SYNTAX Integer32 (1..65535) UNITS "0.1 milliseconds" MAX-ACCESS read-only STATUS deprecated DESCRIPTION " The minimum sample period for recordings supported by the device in units of 0.1 milliseconds. NTCIP1201-RecMechV2.recMechMinSamplePeriod 1.3.6.1.4.1.1206.4.1.1.7.9.4" ::= { recMech 4 } recMaxSamplePeriod OBJECT-TYPE SYNTAX Integer32 (1..65535) UNITS "0.1 milliseconds" MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The maximum sample period for recordings supported by the device in units of 0.1 milliseconds. NTCIP1201-RecMechV2.recMechMaxSamplePeriod 1.3.6.1.4.1.1206.4.1.1.7.9.5" ::= { recMech 5 } recSamplePeriodResolution OBJECT-TYPE SYNTAX Integer32 (1..65535) UNITS "0.1 milliseconds" MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The sample period resolution for recordings supported by the device in units of 0.1 milliseconds. Allowable sample periods are restricted to (recMinSamplePeriod + recSamplePeriodResolution * n) where n is integer, 0 <= n, and n <= (recMaxSamplePeriod- recMinSamplePeriod)/recSamplePeriodResolution ISO26048-1-Recording.fdRecordingSamplePeriodResolution 1.3.6.1.4.1.1206.4.1.1.7.9.6" ::= { recMech 6 } recConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF RecConfigEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "A table containing Recording Mechanism Configuration information. The number of rows in this table is equal to the maxRecConfigs object. This table defines the parameters that the device monitors to create a recording.
static ISO26048-1-Recording.fdRecordingFactoryTable & ISO26048-1- CondTrigger.fdCondTriggerTable (ISO 26048-1) The replacement design divides the recConfigTable into two tables: one that defines triggers that can be used to start recordings or other actions and a second table that defines what to record when the recording action is triggered. 1.3.6.1.4.1.1206.4.1.1.7.9.7" ::= { recMech 7 } recConfigEntry OBJECT-TYPE SYNTAX RecConfigEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "This object defines an entry in the recording configuration table. ISO26048-1-Recording.fdRecordingFactoryEntry & ISO26048-1- CondTrigger.fdCondTriggerEntry (ISO 26048-1) The replacement trigger table has two indicies: an owner and a name. The replacement recording factory table has three indicies, an owner, the class name, and the factory name. In addition to the other changes described, the trigger table adds the following columns: - a textual description of the trigger - an indication whether the comparison is based on the current object value or a delta from its previous reading - an octet-based comparison value since SNMPv3 discourages the use of Opaque - a wildcard that allows defining the same condition on multiple comparison OIDs (e.g., all rows of a table) - indications of the target and context of the comparison object; in other words, the comparison can be performed by a proxy agent or can reference another device to get the object value to compare against - the frequency at which the comparison is made - a truthDuration that allows the configuration to require the evaluation to be true for some length of time prior to firing the trigger. - startup states that define whether the triggers startup in a fired or unfired state (for hysteresis, there are two startups) - a pointer to the action table that identifies the action(s) to be performed. - an error message object that allows a device to report configuration errors. - counters for the number of times the trigger has fired, had evaluation errors, and activation errors. - an indication of the type of storage to use - a RowStatus object. The recMech factory table adds the following columns: - the security data used to activate the row and that will be used to retrieve values for the recording - object contexts, which allows a proxy/hrbrid agent to capture information from another context - A StorageType object 1.3.6.1.4.1.1206.4.1.1.7.9.7.1" INDEX { recConfigID } ::= { recConfigTable 1 } RecConfigEntry ::= SEQUENCE { recConfigID Integer32, recConfigClass Integer32, recConfigMode INTEGER, recConfigCompareValue Integer32, recConfigCompareValue2 Integer32, recConfigCompareOID OBJECT IDENTIFIER, recConfigRecordOID OBJECT IDENTIFIER, recConfigTriggerPoint Integer32, recConfigSamplePeriod Integer32, recConfigSampleOID OBJECT IDENTIFIER, recConfigNumEntries Integer32, recConfigAction INTEGER, recConfigStatus INTEGER} recConfigID OBJECT-TYPE SYNTAX Integer32 (1..65534) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This object contains the row number which is used to identify the recording associated with this row in the recConfigTable. The number of recording configuration IDs shall not exceed the value indicated in the maxRecConfigs object. ISO26048-1-Recording.fdRecordingFactoryName The replacement object is an SnmpAdminString 1.3.6.1.4.1.1206.4.1.1.7.9.7.1.1" ::= { recConfigEntry 1 } recConfigClass OBJECT-TYPE SYNTAX Integer32 (1..254) MAX-ACCESS read-write STATUS deprecated DESCRIPTION " This object contains the class value to assign to the recording associated with this row in the recording configuration table. This value is used in the recording table to organize various recordings defined in this table into logical groupings. This value shall not exceed the maxRecClasses object value. ISO26048-1-Recording.fdRecordingClassName A recording cannot be recorded if the RecClass has an recClassLimit of zero (0). The replacement object is an index for the table 1.3.6.1.4.1.1206.4.1.1.7.9.7.1.2" DEFVAL { 1 } ::= { recConfigEntry 2 } recConfigMode OBJECT-TYPE SYNTAX INTEGER { other (1), onChange (2), greaterThanValue (3), smallerThanValue (4), hysteresisBound (5), periodic (6), andedWithValue (7) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This object specifies the mode of operation for this recording. The modes are defined as follows: Value Description other the recording mode of operation is not described in this standard, refer to the device manual. onChange trigger a recording when the object value referenced by recConfigCompareOID changes. The values of recConfigCompareValue and recConfigCompareValue2 are ignored in this mode. greaterThanValue trigger a recording when the object value referenced by recConfigCompareOID becomes greater than the value of recConfigCompareValue for the time (tenth seconds) defined by recConfigCompareValue2 (zero means immediate logging). smallerThanValue trigger a recording when the object value referenced by recConfigCompareOID becomes less than the value of recConfigCompareValue for the time (tenth seconds) defined by recConfigCompareValue2 (zero means immediate logging). hysteresisBound trigger a recording when the object value referenced by recConfigCompareOID becomes less than or greater than the bound values. The lowerbound value is the lower value of recConfigCompareValue and recConfigCompareValue2; the upperbound value is the higher value of the two values. When the object value becomes greater than the upper bound value, subsequent triggering of upperbound conditions shall not occur until the object value becomes less than the lower bound value. When the object value becomes less than the lower bound value, subsequent triggering of lowerbound conditions shall not occur until the object value becomes greater than the upper bound value. periodic trigger a recording every x seconds, where x is defined by the value stored in recConfigCompareValue. The values stored in recConfigCompareValue2 and recConfigCompareOID are ignored in this mode. andedWithValue trigger a recording when the object value referenced by recConfigCompareOID ANDED with the value of recConfigCompareValue is NOT equal to zero for the time (tenth seconds) defined by recConfigCompareValue2 (zero means immediate logging). This allows monitoring of a specific bit; the condition becomes true anytime that any one of the selected bits become true. ISO26048-1-CondTrigger.fdCondTriggerMode (ISO 26048-1) The replacement object adds the following modes: equal, notEqual, creation, deletion. It also distinguishes between an integer- based and octet-string-based bitwise comparison, which is required due to the elimination of Opaque. 1.3.6.1.4.1.1206.4.1.1.7.9.7.1.3" DEFVAL { onChange } ::= { recConfigEntry 3 } recConfigCompareValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This object contains the comparison value to use with recConfigMode values (greaterThanValue, smallerThanValue, hysteresisBound ). No value within this object is necessary when the recConfigMode-object has the value onChange (2). ISO26048-1-CondTrigger.fdCondTriggerValue (ISO 26048-1) The value is a signed, 4-octet integer 1.3.6.1.4.1.1206.4.1.1.7.9.7.1.4" DEFVAL { 0 } ::= { recConfigEntry 4 } recConfigCompareValue2 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS deprecated DESCRIPTION "If the recConfigMode is set to hysteresisBound, this object specifies the second comparison value for the hysteresis. If the recConfigMode is set to greaterThanValue, smallerThanValue, or andedWithValue, this object specifies the time (in tenth of seconds, +1 tenth / -0 tenths) for which the samples used for comparison are true prior to the triggering condition becoming true. If the recConfigMode is set to onChange or periodic, the value of this object shall be ignored. The amount of time the condition istrue is measured in tenths of a second. The accuracy of this timer is limited to +1 tenth of a second and:0 tenths of a second. If the trigger is true for at least the time shown in this parameter +1 tenth of a second, the condition shall trigger a recording. It is recognized that some designs only sample the condition periodically, in which case the condition is deemed true for at least the time indicated by this object before the trigger becomes true and the trigger shall always become true if the condition is true for a duration equal to the value shown in this object plus 1 tenth of a second. ISO26048-1-CondTrigger.fdCondTriggerValue2 (ISO 26048-1) 1.3.6.1.4.1.1206.4.1.1.7.9.7.1.5" DEFVAL { 0 } ::= { recConfigEntry 5 } recConfigCompareOID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-write STATUS deprecated DESCRIPTION " This object contains the object identifier which references the value against which the comparison is made. If the recConfigMode is set to periodic, the value of this object shall be ignored. If the recConfigMode is set to greaterThanValue, smallerThanValue or hysteresisBound, this object is required to reference an object whose SYNTAX resolves to a ranged or unranged INTEGER. As with all other objects that are sub-ranged by a given implementation, an agent should return a badValue error if it receives a set command indicating a OID which is not supported by the implementation or which is not zeroDotZero. ISO26048-1-CondTrigger.fdCondTriggerObject (ISO 26048-1) 1.3.6.1.4.1.1206.4.1.1.7.9.7.1.6" DEFVAL { zeroDotZero } ::= { recConfigEntry 6 } recConfigRecordOID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This object contains the object identifier which indicates what value to record in a recording (e.g., signal states). As with all other objects that are sub-ranged by a given implementation, an agent should return a badValue error if it receives a set command indicating a value which is not supported by the implementation. The valid value range of this object shall not include any values, other than zeroDotZero, that do not correspond to objects that may exist within the agent, although it may be further restricted. The valid value range of this object shall not include objects under the following nodes: Security - { nema transportation devices global security } CHAP - { nema transportation protocols layers chap } ISO26048-1-Recording.fdRecordingFactorySampleOID The replacement object does not contrain values other than requiring the user to have rights to access the parameter when configuring and when sampling. 1.3.6.1.4.1.1206.4.1.1.7.9.7.1.7" DEFVAL { zeroDotZero } ::= { recConfigEntry 7 } recConfigTriggerPoint OBJECT-TYPE SYNTAX Integer32 (0..100) UNITS "percent" MAX-ACCESS read-write STATUS deprecated DESCRIPTION " This object contains the value of the recording trigger point in percent relative to the recConfigNumEntries. The device needs to collect pre-event records prior to the trigger occurring and ends the recording after recConfigNumEntries have been recorded. A value of zero (0) means to start the recording once the trigger condition occurs whereas a value of 100 means to stop the recording with the last record being the one collected immediately following the trigger condition occurring. If the trigger point is less than 100 then at least one record entry needs to occur after the trigger point. ISO26048-1-Recording.fdRecordingFactoryPreSamples 1.3.6.1.4.1.1206.4.1.1.7.9.7.1.8" DEFVAL { 80 } ::= { recConfigEntry 8 } recConfigSamplePeriod OBJECT-TYPE SYNTAX Integer32 (0..65535) UNITS "0.1 milliseconds" MAX-ACCESS read-write STATUS deprecated DESCRIPTION " This object contains the sample period for recordings collected at specified by this configuration. The sample period is expressed in units of 0.1 milliseconds. Allowable sample periods are restricted to a value of zero (0) or (recMinSamplePeriod + recSamplePeriodResolution * n) where n is integer, 0 <= n, and n <= (recMaxSamplePeriod- recMinSamplePeriod)/recSamplePeriodResolution If the value is zero (0), then the samples are not collected on a periodic basis, but rather a new sample is collected whenever the value of the object specified by recConfigSampleOID changes (i.e. similar to event log 'on-change' mode). A set to any other value results in a badValue response. ISO26048-1-Recording.fdRecordingFactorySamplePeriod 1.3.6.1.4.1.1206.4.1.1.7.9.7.1.9" DEFVAL { 1000 } ::= { recConfigEntry 9 } recConfigSampleOID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-write STATUS deprecated DESCRIPTION " This object contains the object identifier which references the value against which the 'on-change' comparison is made. If recConfigSamplePeriod is non-zero, then the value of this object shall be ignored. As with all other objects that are sub-ranged by a given implementation, an agent should return a badValue error if it receives a set command indicating a OID which is not supported by the implementation or which is not zeroDotZero. ISO26048-1-Recording.fdRecordingFactoryMonitorOID 1.3.6.1.4.1.1206.4.1.1.7.9.7.1.10" DEFVAL { zeroDotZero } ::= { recConfigEntry 10 } recConfigNumEntries OBJECT-TYPE SYNTAX Integer32 (0..4095) UNITS "records" MAX-ACCESS read-write STATUS deprecated DESCRIPTION " This object contains the maximum number of records in a recording defined by this configuration. A recording which collects its full amount of pre-events and post events creates a recording of this number of entries. If this object is zero (0), then no recordings are created based on this configuration. ISO26048-1-Recording.fdRecordingFactorySampleLimit If one wants to use block objects to retrieve a recording, then one should consider that block starting index value is limited to the range 00..255, and the number of entries above 255 is dependent on the size of the recEntry and packet size limitations. The replacement object has a syntax of ITSUnsigned16. 1.3.6.1.4.1.1206.4.1.1.7.9.7.1.11" DEFVAL { 100 } ::= { recConfigEntry 11 } recConfigAction OBJECT-TYPE SYNTAX INTEGER { other (1), disabled (2), record (3) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "The value of this object indicates what action shall take place when this configuration is triggered. other - indicates that the action is other than defined in this standard. disabled - no recording is created due to this configuration. record - a recording is created in the recording table when this configuration is triggered. ISO26048-1-Recording.fdRecordingFactoryRowStatus The replacement table is dynamic. 1.3.6.1.4.1.1206.4.1.1.7.9.7.1.12" DEFVAL { disabled } ::= { recConfigEntry 12 } recConfigStatus OBJECT-TYPE SYNTAX INTEGER { other (1), disabled (2), record (3), error (4) } MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The value of this object indicates the current status of the configured recording. Upon setting any object in this row of the recConfigTable, the agent determines if the setting is valid, and sets this object to one of the following states: other indicates that the action is successfully set to a mode other than that defined in this standard disabled indicates that the action is set to disabled record indicates that the action is successfully set to the record state after passing consistency checks. error indicates that the requested action could not be implemented due to a consistency check ISO26048-1-Recording.fdRecordingFactoryRowStatus The replacement table is dynamic. 1.3.6.1.4.1.1206.4.1.1.7.9.7.1.13" ::= { recConfigEntry 13 } maxRecordings OBJECT-TYPE SYNTAX Integer32 (1..65534) UNITS "records" MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The maximum, fixed number of rows that can be used within the recRecordingTable. The replacement for recRecordingTable is not associated with an explicit row limitation just a size limitation given by recMechV2ClassTableSizeLimit and adminRecMechSizeLimit. 1.3.6.1.4.1.1206.4.1.1.7.9.8" ::= { recMech 8 } recRecordingTable OBJECT-TYPE SYNTAX SEQUENCE OF RecRecordingEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "A table containing information about Recordings both completed and in process. A request for an object from a row that has not been instantiated or has been cleared shall return a noSuchName error.
dynamic ISO26048-1-Recording.fdRecordingRecordingTable 1.3.6.1.4.1.1206.4.1.1.7.9.9" ::= { recMech 9 } recRecordingEntry OBJECT-TYPE SYNTAX RecRecordingEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "This object defines an entry in the recording table ISO26048-1-Recording.fdRecordingRecordingEntry The index for the replacement table has a preceding owner column. It also has a delete column that allows for the deletion of the recording, including all of its samples. 1.3.6.1.4.1.1206.4.1.1.7.9.9.1" INDEX { recordingClass, recordingNumber } ::= { recRecordingTable 1 } RecRecordingEntry ::= SEQUENCE { recordingClass Integer32, recordingNumber Integer32, recordingID Integer32, recordingConfigID Integer32, recordingTriggerTime OCTET STRING, recordingStatus INTEGER, recordingTriggerRecNum Integer32, recordingNumEntries Integer32} recordingClass OBJECT-TYPE SYNTAX Integer32 (1..254) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This object contains the class of the associated recording as defined in the recConfigTable. ISO26048-1-Recording.fdRecordingClassName The syntax of the replacement object is SnmpAdminString. 1.3.6.1.4.1.1206.4.1.1.7.9.9.1.1" ::= { recRecordingEntry 1 } recordingNumber OBJECT-TYPE SYNTAX Integer32 (1..254) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The recording number within this class for this recording. Recording numbers shall be assigned starting at 1 and shall increase to the value specified by the associated recClassLimit for the class associated with the rows. Recordings shall maintain a chronological ordering in the table, based on their recordingTriggerTime value, with the oldest recording of a class occupying the row with recordingNumber = 1, and subsequent recordings filling subsequent rows. This ordering shall be maintained for those rows still remaining when recordings are cleared. ISO26048-1-Recording.fdRecordingRecordingIndex The syntax of the replacement object is ITSPositive16. The replacement table does not attempt to keep the oldest entry in slot one; clearance of rows is based on overall size rather than number of entries, which makes this type of row management more difficult - but since row numbers do not change, managers can keep track of the last row number retrieved and decrease the probability of missing a recording. A manager can also use a get-next operation to discover where the rows start in the table. 1.3.6.1.4.1.1206.4.1.1.7.9.9.1.2" ::= { recRecordingEntry 2 } recordingID OBJECT-TYPE SYNTAX Integer32 (1..65534) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This object contains the recording ID that is used as an index into recording entries table (recEntriesTable) when accessing record entries that belong to this recording. The recording ID is assigned to a recording upon creation of its first record entry and does not change throughout the life of the recording. The recording IDs are not necessarily assigned sequentially. The replacement for the recEntriesTable uses the four indices owner, class name, recording ID, and sample number rather than using a single identifier to join class name and recording. 1.3.6.1.4.1.1206.4.1.1.7.9.9.1.3" ::= { recRecordingEntry 3 } recordingConfigID OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This object contains the recording configuration ID (from the recConfigTable) that caused this table entry. It indicates the row in the recConfig table responsible for this recording entry. ISO26048-1-Recording.fdRecordingRecordingTrigger The syntax of the replacement object is SnmpAdminString. 1.3.6.1.4.1.1206.4.1.1.7.9.9.1.4" ::= { recRecordingEntry 4 } recordingTriggerTime OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS deprecated DESCRIPTION " The time that the recording was triggered at. This object consists of a string of six (6) octets. The first four (4) octets reflect the value of globalTime when the recording was triggered. The last two (2) octets reflect the time in milliseconds the trigger occurred after the start of the second. The recording shall be detected and timestamped within one recSamplePeriodResolution unit of time from the recording being triggered. ISO26048-1-Recording.fdRecordingRecordingDate & recMechV2RecordingTime The replacement objects conform to the new date/time formats. 1.3.6.1.4.1.1206.4.1.1.7.9.9.1.5" ::= { recRecordingEntry 5 } recordingStatus OBJECT-TYPE SYNTAX INTEGER { available (1), preevent (2), triggered (3), complete (4) } MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The value of this object reflects the state of the recording located in this row. Value Description available this row is available for a new recording to be initiated for this recording class. When a recording is cleared, the value is set to available preevent the recording defined by recConfigID is collecting pre-event record entries. Note: If the trigger point is set to zero (0) percent or the trigger condition is already satisfied when the recConfigID is configured, then the value transitions straight from available to triggered. triggered the recording defined by recConfigID has triggered and is now collecting post event records. If the trigger point was set to 100 percent, then the value transitions straight from preevent to complete. If a recording was triggered and the device experienced a power failure, then upon power restoration it shall change the value to complete. Triggered recordings shall survive a power outage. complete the recording defined by recConfigID is now complete (i.e. collected all of its post events) and ready for retrieval. Completed recordings shall survive a power outage. ISO26048-1-Recording.fdRecordingRecordingStatus 1.3.6.1.4.1.1206.4.1.1.7.9.9.1.6" ::= { recRecordingEntry 6 } recordingTriggerRecNum OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This object contains the record entry number of the trigger record entry. A value of zero (0) means that the recording has not triggered yet. ISO26048-1-Recording.fdRecordingRecordingTriggerSample 1.3.6.1.4.1.1206.4.1.1.7.9.9.1.7" ::= { recRecordingEntry 7 } recordingNumEntries OBJECT-TYPE SYNTAX Integer32 (0..65535) UNITS "entries" MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The current number of recording entries in this recording. A value of zero (0) is only valid if the recording is available for use. A completed recording does not always have recConfigNumEntries record entries in it. ISO26048-1-Recording.fdRecordingRecordingNumSamples 1.3.6.1.4.1.1206.4.1.1.7.9.9.1.8" ::= { recRecordingEntry 8 } maxRecEntries OBJECT-TYPE SYNTAX Integer32 (1..65535) UNITS "records" MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The maximum, fixed number of rows that can be used within the recEntriesTable. The replacement for recEntriesTable is not associated with an explicit row limitation just a size limitation given by recMechV2ClassTableSizeLimit and adminRecMechSizeLimit. 1.3.6.1.4.1.1206.4.1.1.7.9.10" ::= { recMech 10 } recEntriesTable OBJECT-TYPE SYNTAX SEQUENCE OF RecEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "A table containing the discrete Recording entry records. A request for an object from a row that has not been instantiated or has been cleared shall return a noSuchName error.
dynamic ISO26048-1-Recording.fdRecordingSampleTable 1.3.6.1.4.1.1206.4.1.1.7.9.11" ::= { recMech 11 } recEntry OBJECT-TYPE SYNTAX RecEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "This object defines an entry in the recording entry table. All entries within a recording shall be ordered chronologically from oldest to newest. ISO26048-1-Recording.fdRecordingSampleEntry The index for the replacement table uses four fields: owner, class, recording, and sample. 1.3.6.1.4.1.1206.4.1.1.7.9.11.1" INDEX { recordingID, recEntryNumber } ::= { recEntriesTable 1 } RecEntry ::= SEQUENCE { recEntryNumber Integer32, recSampleTime OCTET STRING, recValue Opaque} recEntryNumber OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The entry number within this recording for this record. Entry numbers shall be assigned starting at 1 and shall increase up to the value specified by the associated recConfigNumEntries. A value of zero indicates that the row is unused (cleared). ISO26048-1-Recording.fdRecordingSampleNum 1.3.6.1.4.1.1206.4.1.1.7.9.11.1.1" ::= { recEntry 1 } recSampleTime OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The time that the record entry was sampled at. This object consists of a string of six (6) octets. The first four (4) octets reflect the value of controllerLocalTime when the entry was sampled. The last two (2) octets reflect the time in milliseconds the sample occurred after the start of the second. The entry shall be collected within one recSamplePeriodResolution unit of time from the sample being triggered and timestamped with the time of collection ISO26048-1-Recording.fdRecordingSampleTime The syntax for the replacement object is ITSDailyTimeStamp, which does not provide the date. However, the date is provided in the Trigger time. Assuming the sample period is relatively short, this should not cause a problem. For recordings with many samples and/or long sample intervals, the date can be calculated - with the one exception of on change sampling for rare events. owner, class, recording, and sample. 1.3.6.1.4.1.1206.4.1.1.7.9.11.1.2" ::= { recEntry 2 } recValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The value of this object is set to the BER encoding of the value referenced by the recConfigRecordOID of the associated recordingConfigID when the entry was collected. Its length is variable. The value shall not contain any padding characters either before or after the values. ISO26048-1-Recording.fdRecordingSampleValue Opaque objects are doubly wrapped. For SNMP operations, which use BER, this would be {type, length, {type, length, value}}. For example, a zero-length octet string, would be encoded in BER as 0x44 02 04 00. For STMP or SFMP operations, which use OER, this would be { length, {type, length, value}}. For example, the same example would be encoded in OER as 0x02 04 00. The syntax of the replacement object is ITSOerString. 1.3.6.1.4.1.1206.4.1.1.7.9.11.1.3" ::= { recEntry 3 } numRecordings OBJECT-TYPE SYNTAX Integer32 (0..65535) UNITS "recordings" MAX-ACCESS read-only STATUS deprecated DESCRIPTION " This object is a counter that gets incremented every time a recording is completed and shall initialize to zero at power up. The value shall roll over each time it exceeds the maximum of 65535. ISO26048-1-Recording.fdRecordingOwnerRecordingCtr & adminRecMechV2RecordingCtr The syntax of the replacement objects is ZeroBasedCounter32. 1.3.6.1.4.1.1206.4.1.1.7.9.12" ::= { recMech 12 } recClearClasses OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This object commands the device to clear a recording class from recClassTable. A SET of zero has no effect on any recording classes. A SET = n, n <= maxRecClasses, shall cause recClassNumber = n to be deleted from the recClassTable and all related recording configurations, their recordings, their recording entries, their recording activities shall be deleted from the recConfigTable, recRecordingTable, and recEntriesTable respectively. A SET of 255 shall cause all entries in the recClassTable, recConfigTable, recRecordingTable, and recEntriesTable to be deleted. Upon performing the action requested, the device shall SET this object to zero (0). A GET shall always return zero (0). ISO26048-1-Recording.fdRecordingClassRowStatus, recMechV2OwnerClearAllClasses, & adminRecMechClearAllClasses 1.3.6.1.4.1.1206.4.1.1.7.9.13" ::= { recMech 13 } recClearConfigurations OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This object commands the device to clear a recording configuration from the recConfigTable. A SET of zero has no effect on any recording configurations. A SET = n, n <= maxRecConfigs, shall cause recConfigID = n to be deleted from the recRecordingTable and all related recordings, their recording entries, and their recording activities shall be deleted from the recRecordingTable and recEntriesTable respectively. A SET of n = 65535 shall cause all entries in the recConfigTable, recRecordingTable, and recEntriesTable to be deleted. Upon performing the action requested, the device shall SET this object to zero (0). A GET shall always return zero (0). ISO26048-1-Recording.fdRecordingFactoryRowStatus, recMechV2OwnerClearAllFactories, adminRecMechClearAllFactories, COND_NOTIFICATIONS-MIB.fdCondTriggerRowStatus (ISO 26048-1) There is not a clear all for the conditional trigger. 1.3.6.1.4.1.1206.4.1.1.7.9.14" ::= { recMech 14 } recClearRecordingData OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This object commands the device to clear a recording from the recRecordingTable and recEntriesTable. A SET of zero has no effect on any recordings. A SET = n, n <= maxRecordings, shall cause recRecordingID = n to be deleted from the recRecordingTable and all record entries related to the recording to be deleted from recEntriesTable. A SET of n = 65535 shall cause all entries in both the recRecordingTable and recEntriesTable to be deleted. Upon performing the action requested, the device shall SET this object to zero (0). A GET shall always return zero (0). A device shall immediately start collecting new pre-event records for all active recording configurations. ISO26048-1-Recording.fdRecordingRecordingDelete, recMechV2OwnerClearAllRecordings, & adminRecMechClearAllRecordings 1.3.6.1.4.1.1206.4.1.1.7.9.15" ::= { recMech 15 } END