-- OIDref derived MIB transcription. Original PDF: https://www.ntcip.org/file/2018/11/NTCIP1204v0113c.pdf
-- Publisher front matter and notices follow as comments.
--                            A Joint Standard of AASHTO, ITE, and NEMA
-- 
-- 
-- 
-- 
--                         NTCIP 1204:1998                                   v01.13
-- 
-- 
-- 
--        National Transportation
--        Communications for ITS Protocol
-- 
--        Object Definitions for
--        Environmental Sensor Stations (ESS)
-- 
--                                                    November 23, 2001
-- 
--                   Includes Jointly Approved NTCIP 1204 Amendment 1 v02
-- 
-- This Adobe® PDF copy of an NTCIP standard is available at no-cost for a limited time through support
-- from the U.S. DOT / Federal Highway Administration, whose assistance is gratefully acknowledged.
-- 
-- 
-- 
-- 
-- Published by
-- 
-- American Association of State Highway and Transportation Officials (AASHTO)
-- 444 North Capitol Street, N.W., Suite 249
-- Washington, D.C. 20001
-- 
-- Institute of Transportation Engineers (ITE)
-- 1099 14th Street, N.W., Suite 300 West
-- Washington, D.C. 20005-3438
-- 
-- National Electrical Manufacturers Association (NEMA)
-- 1300 North 17th Street, Suite 1847
-- Rosslyn, Virginia 22209-3801
-- 
-- 
-- 
--  2001 AASHTO / ITE / NEMA. All rights reserved.
-- 
--  2001 by the American Association of State Highway and Transportation Officials (AASHTO), the Institute of Transportation
-- Engineers (ITE), and the National Electrical Manufacturers Association (NEMA). All intellectual property rights, including, but not
-- limited to, the rights of reproduction in whole or in part in any form, translation into other languages and display are reserved by the
-- copyright owners under the laws of the United States of America, the Universal Copyright Convention, the Berne Convention, and
-- the International and Pan American Copyright Conventions. Except for the MIB or the PRL, do not copy without written permission
-- of either AASHTO, ITE, or NEMA.
-- 
-- 
-- 
-- 
-- © 2001 AASHTO / ITE / NEMA
-- 
--                                                                                     NTCIP 1204:1998 v01.13
--                                                                                                     Page i
-- 
--                                         ACKNOWLEDGEMENTS
-- 
-- 
-- This publication was prepared by the NTCIP Environmental Sensor Station Working Group, which is a
-- subdivision of the Joint Committee on the NTCIP. The Joint Committee is organized under a
-- Memorandum of Understanding among the American Association of State Highway and Transportation
-- Officials (AASHTO), the Institute of Transportation Engineers (ITE), and the National Electrical
-- Manufacturers Association (NEMA). The Joint Committee on the NTCIP consists of six representatives
-- from each of the standards organizations, and provides guidance for NTCIP development.
-- 
-- At the time that this document was prepared, the following individuals were members of the NTCIP
-- Environmental Sensor Station Working Group:
-- • Golden Boyce
-- • Richard Carey
-- • Peter Davies
-- • Ed Fleege
-- • Rob Fox
-- • Mark Greer
-- • Robert Patterson
-- • Paul Pisano
-- • Blaine Tsugawa
-- • Ken Vaughn
-- • John Whited
-- • George Yanowski
-- 
-- Other individuals providing input to the document include:
-- • Bob De Roche
-- • Stan Doore
-- • Curtis Gobeli
-- • Bob Hart
-- • Jason Hedley
-- • Colin Rayman
-- • Elmar Reiter
-- • Susan Tonkin
-- • Jerry Waldman
-- 
-- In addition to the many volunteer efforts, recognition is also given to those organizations who supported
-- the efforts of the working groups by providing comments and funding for the standard, including:
-- • Aanderaa Instruments
-- • AURORA
-- • California Department of Transportation
-- • Castle Rock Consultants
-- • Coastal Environmental Systems
-- • Colorado Department of Transportation
-- • Federal Highway Administration
-- • Georgia Institute of Technology
-- • Idaho Department of Transportation
-- • Illinois Department of Transportation
-- • Iowa Department of Transportation
-- • JAYCOR
-- • Maine Department of Transportation
-- • Minnesota Department of Transportation
-- • New York Department of Transportation
-- 
-- 
-- 
-- © 2001 AASHTO / ITE / NEMA                                            Do Not Copy Without Written Permission
-- 
-- NTCIP 1204:1998 v01.13
-- Page ii
-- 
-- 
-- •   Odetics ITS
-- •   Ontario Ministry of Transportation
-- •   Office of the Federal Coordinator for Meteorology
-- •   Parsons Transportation Group
-- •   P B Farradyne, Inc.
-- •   Peek Traffic - Transyt Corp.
-- •   Surface Systems Inc.
-- •   Texas Transportation Institute
-- •   University of North Dakota
-- •   Vaisala, Inc.
-- •   Viggen Corporation
-- •   Virginia Department of Transportation
-- •   Weather Solutions Group
-- •   WELS Research Corporation
-- •   Wisconsin Department of Transportation
-- 
-- 
-- 
-- 
-- Do Not Copy Without Written Permission                  © 2001 AASHTO / ITE / NEMA
-- 
--                                                                                       NTCIP 1204:1998 v01.13
--                                                                                                      Page iii
-- 
--                                                 FOREWORD
-- 
-- 
-- This document uses only metric units.
-- 
-- This publication defines the data elements and conformance requirements for environmental sensor
-- stations. It defines requirements that are applicable to all NTCIP environmental sensor stations and it also
-- contains optional and conditional clauses that are applicable to specific environments for which they are
-- intended. There are no annexes to this document.
-- 
-- This document is an NTCIP Data Dictionary Standard. Data Dictionary Standards provide formal
-- definitions of data elements for use within NTCIP systems; they are formally approved by AASHTO, ITE,
-- and NEMA through a ballot process, after a formal recommendation by the NTCIP Joint Committee.
-- 
-- For more information about NTCIP standards, visit the NTCIP Web Site at http://www.ntcip.org. For a
-- hardcopy summary of NTCIP information, contact the NTCIP coordinator at the above address.
-- 
-- In preparation of this NTCIP document, input of users and other interested parties was sought and
-- evaluated. Inquires, comments, and proposed or recommended revisions should be submitted to:
-- 
--           NTCIP Coordinator
--           National Electrical Manufacturers Association
--           1300 North 17th Street, Suite 1847
--           Rosslyn, VA 22209-3801
--           fax:    (703) 841-3331
--           e-mail: ntcip@nema.org
-- 
-- Approvals
-- 
-- This document was separately balloted and approved by AASHTO, ITE, and NEMA after
-- recommendation by the Joint Committee on the NTCIP. Each organization has approved this standard
-- as the following standard type, as of the date:
-- 
--           AASHTO – Standard Specification; 1998
--           ITE – Software Standard; June 1998
--           NEMA – Standard; August 1998
-- 
-- 
-- History
-- 
-- From 1996 to 1998, this document was referenced as NEMA TS 3.7. However, to provide an organized
-- numbering scheme for the NTCIP documents, this document is now referenced as NTCIP 1204. The
-- technical specifications of NTCIP 1204 are identical to the former references, except as noted in the
-- development history below:
-- 
--           TS 3.7 version 97.01.11. November 1997 – Approved by AASHTO, ITE, and NEMA in 1998.
-- 
--           TS 3.7 Amendment 1, version 98.01.02. September 1998 – Approved by AASHTO and NEMA in
--           1999 and approved by ITE in 2001.
-- 
--           NTCIP 1204:1998 v01.12. September 1998 – Combined version 01.11 and Amendment 1
--           version 02, converted to revised standard numbering scheme, and made changes to the front
--           matter. Added underline and strikethrough to indicate changes in Subclauses 3.2.2, 3.3.1,
--           3.8.11, 3.8.12, 3.11.2.10, 3.11.2.11, 3.11.2.12, 3.11.4.3, 3.11.4.4, 3.14.1 through 3.14.7, and
--           4.2.1.
-- 
-- 
-- 
-- © 2001 AASHTO / ITE / NEMA                                              Do Not Copy Without Written Permission
-- 
-- NTCIP 1204:1998 v01.13
-- Page iv
-- 
-- 
-- 
--         NTCIP 1204:1998 v01.13. November 2001 – Reformatted for printing: incremented version
--         number and updated date. Updated document to NTCIP 8002 v04 Template format, added
--         approvals and history to Foreword, and converted references to TS 3 Standards to renumbered
--         NTCIP Standards. The underline and strikethrough format used to indicate the amendment
--         changes was removed. The normative reference to WMO BUFR was corrected and References
--         were updated.
-- 
-- 
-- 
-- 
-- Do Not Copy Without Written Permission                                    © 2001 AASHTO / ITE / NEMA
-- 
--                                                                                     NTCIP 1204:1998 v01.13
--                                                                                                     Page v
-- 
--                                             INTRODUCTION
-- 
-- 
-- This publication provides definitions of data elements for use with environmental sensor stations (ESS).
-- The data is defined using the Simple Network Management Protocol (SNMP) object-type format as
-- defined in RFC 1212 and would typically be exchanged using one of the NTCIP recognized Application
-- Layers (e.g., SNMP).
-- 
-- This standard defines requirements that are applicable to all NTCIP environments and the standard also
-- contains optional and conditional clauses that are applicable to specific environments for which they are
-- intended.
-- 
-- The following keywords apply to this document: AASHTO, ITE, NEMA, NTCIP, ESS, RWIS, data, data
-- dictionary, object, road weather, air quality.
-- 
-- In 1992, the NEMA 3-TS Transportation Management Systems and Associated Control Devices Section
-- began the effort to develop the NTCIP. The Transportation Section’s purpose was to respond to user
-- needs to include standardized systems communication in the NEMA TS 2 standard, Traffic Controller
-- Assemblies. Under the guidance of the Federal Highway Administration’s NTCIP Steering Group, the
-- NEMA effort was expanded to include the development of communications standards for all
-- transportation field devices that could be used in an Intelligent Transportation Systems (ITS) network.
-- 
-- In September 1996, an agreement was executed among AASHTO, ITE, and NEMA to jointly develop,
-- approve, and maintain the NTCIP standards. One of the first tasks of the joint effort was to establish the
-- Environmental Sensor Station Working Group to standardize ESS equipment communication. The first
-- ESS WG meeting was held in November 1996 to begin the development of this document.
-- 
-- 
-- 
-- 
-- © 2001 AASHTO / ITE / NEMA                                            Do Not Copy Without Written Permission
-- 
-- NTCIP 1204:1998 v01.13
-- Page vi
-- 
-- If you are not willing to abide by the following notices, return these materials immediately.
-- 
--                                    Joint AASHTO, ITE, and NEMA
--                          NTCIP Management Information Base and Data Dictionary
-- 
--                                           DISTRIBUTION NOTICE
-- 
-- To the extent and in the limited event these materials are distributed by AASHTO / ITE / NEMA in the
-- form of a Management Information Base (“MIB”) or Data Dictionary (“DD”), AASHTO / ITE / NEMA
-- extends the following permissions:
-- 
-- (i) you may make and/or distribute unlimited copies (including derivative works) of the MIB, including
-- copies for commercial distribution, provided that (a) each copy you make and/or distribute contains this
-- Notice and (b) each derivative work of the MIB uses the same module name followed by “-,” followed by
-- your Internet Assigned Number Authority (IANA)-assigned enterprise number;
-- (ii) use of the MIB is restricted in that the syntax field may be modified only to reflect a more restrictive
-- subrange or enumerated values;
-- (iii) the description field may be modified but only to the extent that: (a) only those bit values or
-- enumerated values that are supported are listed; and (b) the more restrictive subrange is expressed.
-- 
-- These materials are delivered “AS IS” without any warranties as to their use or performance.
-- 
-- AASHTO / ITE / NEMA AND THEIR SUPPLIERS DO NOT WARRANT THE PERFORMANCE OR
-- RESULTS YOU MAY OBTAIN BY USING THESE MATERIALS. AASHTO/ITE/NEMA AND THEIR
-- SUPPLIERS MAKE NO WARRANTIES, EXPRESS OR IMPLIED, AS TO NONINFRINGEMENT OF
-- THIRD PARTY RIGHTS, MERCHANTABILITY, OR FITNESS FOR ANY PARTICULAR PURPOSE. IN
-- NO EVENT WILL AASHTO, ITE, OR NEMA OR THEIR SUPPLIERS BE LIABLE TO YOU OR ANY
-- THIRD PARTY FOR ANY CLAIM OR FOR ANY CONSEQUENTIAL, INCIDENTAL, OR SPECIAL
-- DAMAGES, INCLUDING ANY LOST PROFITS OR LOST SAVINGS, ARISING FROM YOUR
-- REPRODUCTION OR USE OF THESE MATERIALS, EVEN IF AN AASHTO, ITE, OR NEMA
-- REPRESENTATIVE HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. Some states
-- or jurisdictions do not allow the exclusion or limitation of incidental, consequential, or special damages, or
-- the exclusion of implied warranties, so the above limitations may not apply to you.
-- 
-- Use of these materials does not constitute an endorsement or affiliation by or between AASHTO, ITE, or
-- NEMA and you, your company, or your products and services.
-- 
-- Disclaimer
-- 
-- The information in this publication was considered technically sound by the consensus of persons
-- engaged in the development and approval of the document at the time it was developed. Consensus
-- does not necessarily mean that there is unanimous agreement among every person participating in the
-- development of this document.
-- 
-- AASHTO, ITE, and NEMA standards and guideline publications, of which the document contained herein
-- is one, are developed through a voluntary consensus standards development process. This process
-- brings together volunteers and/or seeks out the views of persons who have an interest in the topic
-- covered by this publication. While AASHTO, ITE, and NEMA administer the process and establish rules
-- to promote fairness in the development of consensus, they do not write the document and they do not
-- independently test, evaluate, or verify the accuracy or completeness of any information or the soundness
-- of any judgments contained in their standards and guideline publications.
-- 
-- AASHTO, ITE, and NEMA disclaim liability for any personal injury, property, or other damages of any
-- nature whatsoever, whether special, indirect, consequential, or compensatory, directly or indirectly
-- resulting from the publication, use of, application, or reliance on this document. AASHTO, ITE, and
-- NEMA disclaim and make no guaranty or warranty, express or implied, as to the accuracy or
-- 
-- 
-- Do Not Copy Without Written Permission                                           © 2001 AASHTO / ITE / NEMA

ESS-MIB DEFINITIONS ::= BEGIN
IMPORTS
  IpAddress, Counter
         FROM RFC1155-SMI
  DisplayString
         FROM RFC1158-SMI
  OBJECT-TYPE
         FROM RFC-1212
  experimental
         FROM NEMA_SMI
  devices
         FROM TMIB;
-- For the purpose of this section, the following OBJECT IDENTIFIERS are used:
ess OBJECT IDENTIFIER ::={devices 5}

essBufr OBJECT IDENTIFIER ::= {ess 1}
-- This node contains objects that describe BUFR information based on the BUFR Standards.

essNtcip OBJECT IDENTIFIER ::= {ess 2}
-- This node contains objects that describe surface transportation environmental information
-- which deviate from the BUFR Standards.

                              
-- These are objects used to describe the identification of the environmental sensor station.
essNtcipIdentification OBJECT IDENTIFIER ::= {essNtcip 1 }

                         
essNtcipCategory OBJECT-TYPE
SYNTAX        INTEGER { other (1),
                        permanent (2),
                        transportable (3),
                        mobile (4)}



                                                                                                             

                      
        

ACCESS          read-only
STATUS          mandatory
DESCRIPTION "Indicates the type of station.
value                     description
other                     of a design not listed in this standard.
permanent                 not designed to be relocated.
transportable             able to be relocated, but does not take readings while
                          moving.
mobile                    capable of taking readings while moving."
::= {essNtcipIdentification 1}

                                 
essNtcipSiteDescription OBJECT-TYPE
SYNTAX          DisplayString (SIZE (0..255))
ACCESS          read-write
STATUS          mandatory
DESCRIPTION "A textual description of the station’s location."
::= {essNtcipIdentification 2}

      -- it is also recognized that there would be a great value of an object to indicate the quality of data;
      -- however, this is a very complex topic and thus we have not determined an appropriate
             mechanism.

                                    
-- Contains objects used to describe the type of data and the type of instrumentation used to
-- collect the data being received from the ess.
essBufrInstrumentation OBJECT IDENTIFIER ::= {essBufr 2 }

                        
essTypeofStation OBJECT-TYPE
                        SYNTAX INTEGER (0..3)
ACCESS            read-only
STATUS            mandatory
DESCRIPTION "Integer value that indicates the type of station. If the station is a hybrid station, it shall be
defined as two stations, one staffed and one automatic.
      value                      description
      0 - automatic              the data is collected electronically/mechanically
      1 - staffed                the data is collected by humans
      3 - missingValue           the type of station is unknown."
REFERENCE "WMO Binary Code form FM 94 BUFR Table B table reference descriptor 0 02 001."
::= {essBufrInstrumentation 1}

-- The definition of the type, make, model, and version of the various sensors connected to the ESS shall
-- be defined in the Global Module Table.

                        
-- Contains objects used to describe the location of the ess that is transmitting the collected data.

essNtcipLocation OBJECT IDENTIFIER ::= {essNtcip 2 }


                 
essLatitude OBJECT-TYPE



                                                                                                             

                                                                                                         
                                                                                                         

SYNTAX          INTEGER (-90000000..90000001)
ACCESS          read-only
STATUS          mandatory
DESCRIPTION "The latitude in 10^-6 degrees of the ESS station. The essLatitude at the North Pole is
90,000,000. The essLatitude at the South Pole is -90,000,000. The value 90,000,001 shall indicate a
missing value."
REFERENCE "Resolution based on on-going location referencing activities; the WMO Binary Code form
FM 94 BUFR Table B table reference descriptor 0 05 001 can be obtained by dividing this value by 10."
::= {essNtcipLocation 1}

                  
essLongitude OBJECT-TYPE
SYNTAX          INTEGER (-180000000..180000001)
ACCESS          read-only
STATUS          mandatory
DESCRIPTION "The east longitude in 10^-6 degrees from the Prime Meridian of the ESS location. The
essLongitude of 180 degrees West shall be -180,000,000. The essLongitude of 180 degrees East shall
be 180,000,000. The value 180,000,001 shall indicate a missing value."
REFERENCE "Resolution based on on-going location referencing activities; the WMO Binary Code form
FM 94 BUFR Table B table reference descriptor 0 06 001 can be obtained by dividing this value by 10."
::= {essNtcipLocation 2}

                      
essVehicleSpeed OBJECT-TYPE
SYNTAX           INTEGER (0..255)
ACCESS           read-only
STATUS           mandatory
DESCRIPTION "Indicates the current speed being reported by the vehicle in kilometers per hour. The
value 255 shall indicate an error condition or missing value."
::= { essNtcipLocation 3}

                        
essVehicleBearing OBJECT-TYPE
SYNTAX          INTEGER (0..361)
ACCESS          read-only
STATUS          mandatory
DESCRIPTION "Indicates the current bearing of the vehicle in degrees, measured clockwise from True
North. The value 361 shall indicate an error condition or missing value."
::= { essNtcipLocation 4 }

                 

essOdometer OBJECT-TYPE
SYNTAX          Counter
ACCESS          read-only
STATUS          mandatory
DESCRIPTION "Indicates the current odometer reading of the vehicle in meters."
::= { essNtcipLocation 5 }

                                 
-- Contains objects used to describe the elevation and atmospheric pressure at the ess that is
-- transmitting the collected data.
essNtcipHeight OBJECT IDENTIFIER ::= {essNtcip 3 }
essBufrLocationVertical OBJECT IDENTIFIER ::= {essBufr 7 }


                                                                                                            

                      
        



                         
essReferenceHeight OBJECT-TYPE
SYNTAX            INTEGER (-400..8001)
ACCESS            read-only
STATUS            mandatory
DESCRIPTION "The reference elevation of the ESS in meters above mean sea level. For a permanent
station, this height shall be measured to the base of the structure; for transportable stations, this height
shall be measured to the ground surface upon which the station resides; and for mobile, this height shall
be measured to the surface under the vehicle. The value 8001 shall indicate an missing value."
REFERENCE "Resolution based on WMO Binary Code form FM 94 BUFR Table B table reference
descriptor 0 07 001."
::= {essNtcipHeight 1}

                        
essPressureHeight OBJECT-TYPE
SYNTAX          INTEGER (-1000..1001)
ACCESS          read-only
STATUS          mandatory
DESCRIPTION "The height of the pressure sensor with respect to the essReferenceHeight in meters.
The value 1001 shall indicate a missing value."
REFERENCE "essRefernceHeight plus this value equals the WMO Binary Code form FM 94 BUFR Table
B table reference descriptor 0 07 001."
::= {essNtcipHeight 2}

                           
essWindSensorHeight OBJECT-TYPE
SYNTAX          INTEGER (-1000..1001)
ACCESS          read-only
STATUS          mandatory
DESCRIPTION "The height of the wind sensor with respect to the essReferenceHeight in meters. The
value 1001 shall indicate a missing value."
::= {essNtcipHeight 3}

                                       
essAtmosphericPressure OBJECT-TYPE
SYNTAX          INTEGER (0..65535)
ACCESS          read-only
STATUS          mandatory
DESCRIPTION "The force per unit area exerted by the atmosphere in 1/10ths of millibars, a.k.a. tenths of
hectoPascals. A value of 65535 shall indicate an error condition or missing value."
REFERENCE "WMO Binary Code form FM 94 BUFR Table B table reference descriptor 0 07 004."
::= { essBufrLocationVertical 4}

                         
-- Contains objects used to describe the wind data that is collected at the ess.
essNtcipWind OBJECT IDENTIFIER ::= {essNtcip 4 }
essBufrWind OBJECT IDENTIFIER ::= {essBufr 11 }

                               
essAvgWindDirection OBJECT-TYPE
SYNTAX        INTEGER (0..361)
ACCESS        read-only



                                                                                                             

                                                                                                         
                                                                                                         

STATUS          mandatory
DESCRIPTION "A two minute average of the direction from which the wind is blowing measured
clockwise in degrees from true North and measured at a height as indicated by essWindSensorHeight. A
value of 361 shall indicate an error condition or missing value."
REFERENCE "WMO Binary Code form FM 94 BUFR Table B table reference descriptor 0 11 001."
::= {essBufrWind 1}

                          
essAvgWindSpeed OBJECT-TYPE
SYNTAX           INTEGER (0..65535)
ACCESS           read-only
STATUS           mandatory
DESCRIPTION "A two minute average of the wind speed in tenths of meters per second measured at a
height as indicated by essWindSensorHeight. A value of 65535 shall indicate an error condition or
missing value."
REFERENCE "WMO Binary Code form FM 94 BUFR Table B table reference descriptor 0 11 002."
::= {essBufrWind 2}

                           
essSpotWindDirection OBJECT-TYPE
SYNTAX           INTEGER (0..361)
ACCESS           read-only
STATUS           mandatory
DESCRIPTION "The direction from which the wind is blowing measured in degrees clockwise from true
North and measured at a height as indicated by essWindSensorHeight. A value of 361 shall indicate an
error condition or missing value. For mobile platforms, the wind direction shall be corrected for vehicle
movement."
::= { essNtcipWind 1}

                       
essSpotWindSpeed OBJECT-TYPE
SYNTAX           INTEGER (0..65535)
ACCESS           read-only
STATUS           mandatory
DESCRIPTION "The wind speed in tenths of meters per second measured at a height as indicated by
essWindSensorHeight. A value of 65535 shall indicate an error condition or missing value. For mobile
platforms, the wind speed shall be corrected for vehicle movement."
::= {essNtcipWind 2}

                      
essWindSituation OBJECT-TYPE
SYNTAX         INTEGER {   other (1),
                           unknown (2),
                           calm (3),
                           lightBreeze (4),
                           moderateBreeze (5),
                           strongBreeze (6),
                           gale (7),
                           moderateGale (8),
                           strongGale (9),
                           stormWinds (10),
                           hurricaneForceWinds (11),
                           gustyWinds (12)}
ACCESS         read-only



                                                                                                            

                      
        

STATUS          mandatory
DESCRIPTION "Describes the weather and travel situation in terms of wind from staffed stations only.
Specific ranges for these values are defined in the Glossary of Meteorology. Defined values are:
        Range                    Meaning
        other                    not defined within this standard, consult manufacturers documentation
        unknown                  Unknown conditions
        calm                     Calm
        lightBreeze              Light breeze
        moderateBreeze           Moderate breeze
        strongBreeze             Strong breeze
        gale                     Gale
        moderateGale             Moderate gale
        strongGale               Strong gale
        stormWinds               Storm winds
        hurricaneForceWinds Hurricane force winds
        gustyWinds               Gusty winds – defined by a peak and a lull of greater than 46.3 tenths of
                                 meters per second within a 2 minute period."
::= {essNtcipWind 3}

                                
essMaxWindGustSpeed OBJECT-TYPE
SYNTAX           INTEGER (0..65535)
ACCESS           read-only
STATUS           mandatory
DESCRIPTION "The maximum wind gust recorded during the 10 minutes preceding the observation at a
height as indicated by essWindSensorHeight and measured in tenths of meters per second. The value
65535 shall indicate an error condition or missing value."
REFERENCE "WMO Binary Code form FM 94 BUFR Table B table reference descriptor 0 11 041."
::= {essBufrWind 41}

                                    
essMaxWindGustDir OBJECT-TYPE
SYNTAX          INTEGER (0..361)
ACCESS          read-only
STATUS          mandatory
DESCRIPTION "The direction of the maximum wind gust recorded during the 10 minutes preceding the
observation at a height as indicated by essWindSensorHeight; measured in degrees clockwise from true
North. The value 361 shall indicate an error condition or missing value."
REFERENCE "WMO Binary Code form FM 94 BUFR Table B table reference descriptor 0 11 043."
::= {essBufrWind 43}

                                
-- Contains objects used to describe the temperature data that is collected at the ess.
essNtcipTemperature OBJECT IDENTIFIER ::= {essNtcip 5 }

                                      
essNumTemperatureSensors OBJECT-TYPE
SYNTAX          INTEGER (0..255)
ACCESS          read-only
STATUS          mandatory
DESCRIPTION "Indicates the number of entries in the temperature sensor table."
::= {essNtcipTemperature 1}

                                 



                                                                                                         

                                                                                                      
                                                                                                      

essTemperatureSensorTable OBJECT-TYPE
SYNTAX          SEQUENCE OF EssTemperatureSensorEntry
ACCESS          not-accessible
STATUS          mandatory
DESCRIPTION "Table containing the temperature sensor data fields."
::= {essNtcipTemperature 2}

essTemperatureSensorEntry OBJECT-TYPE
SYNTAX         EssTemperatureSensorEntry
ACCESS         not-accessible
STATUS         mandatory
DESCRIPTION "Parameters for specific temperature sensor data fields."
INDEX {essTemperatureSensorIndex}
::= {essTemperatureSensorTable 1}

EssTemperatureSensorEntry ::= SEQUENCE {
      essTemperatureSensorIndex                        INTEGER,
      essTemperatureSensorHeight                       INTEGER,
      essAirTemperature                                INTEGER }

                                   
essTemperatureSensorIndex OBJECT-TYPE
SYNTAX         INTEGER (1..255)
ACCESS         read-only
STATUS         mandatory
DESCRIPTION "Enumerated list of row entries that will provide temperature sensor data."
::= {essTemperatureSensorEntry 1}

                                    
essTemperatureSensorHeight OBJECT-TYPE
SYNTAX         INTEGER (-1000..1001)
ACCESS         read-only
STATUS         mandatory
DESCRIPTION "The height of the temperature sensor as measured in meters above
essReferenceHeight."
::= { essTemperatureSensorEntry 2}

                          
essAirTemperature OBJECT-TYPE
SYNTAX           INTEGER (-1000..1001)
ACCESS           read-only
STATUS           mandatory
DESCRIPTION "The dry-bulb temperature in tenths of degrees Celsius. The temperature is an
instantaneous reading at the height specified by essTemperatureSensorHeight. The value 1001 shall
indicate an error condition or missing value."
REFERENCE "Resolution is based on WMO Binary Code form FM 94 BUFR Table B table reference
descriptor 0 12 001; temperature in kelvin is determined by adding 273.15 to this value."
::= { essTemperatureSensorEntry 3}

                              
essWetbulbTemp OBJECT-TYPE
SYNTAX       INTEGER (-1000..1001)
ACCESS       read-only
STATUS       mandatory



                                                                                                         

                      
        

DESCRIPTION "The wet-bulb temperature in tenths of degrees Celsius. The temperature is an
instantaneous reading at the height specified by the essTemperatureSensorHeight as specified in the first
row of the essTemperatureTable. The value 1001 shall indicate an error condition or missing value."
REFERENCE "Resolution is based on WMO Binary Code form FM 94 BUFR Table B table reference
descriptor 0 12 002; temperature in kelvin is determined by adding 273.15 to this value."
::= {essNtcipTemperature 3}

                              
essDewpointTemp OBJECT-TYPE
SYNTAX           INTEGER (-1000..1001)
ACCESS           read-only
STATUS           mandatory
DESCRIPTION "The dewpoint temperature in tenths of degrees Celsius. The temperature is an
instantaneous reading at the height specified by the essTemperatureSensorHeight as specified in the first
row of the essTemperatureTable. The value 1001 shall indicate an error condition or missing value."
REFERENCE "Resolution is based on WMO Binary Code form FM 94 BUFR Table B table reference
descriptor 0 12 003; temperature in kelvin is determined by adding 273.15 to this value."
::= {essNtcipTemperature 4}

                            
essMaxTemp OBJECT-TYPE
SYNTAX            INTEGER (-1000..1001)
ACCESS            read-only
STATUS            mandatory
DESCRIPTION "The maximum temperature in tenths of degrees Celsius recorded during the 24 hours
preceding the observation at the height specified by the essTemperatureSensorHeight as specified in the
first row of the essTemperatureTable. The value 1001 shall indicate an error condition or missing value."
REFERENCE "Resolution is based on WMO Binary Code form FM 94 BUFR Table B table reference
descriptor 0 12 011; temperature in kelvin is determined by adding 273.15 to this value."
::= {essNtcipTemperature 5}

                            
essMinTemp OBJECT-TYPE
SYNTAX            INTEGER (-1000..1001)
ACCESS            read-only
STATUS            mandatory
DESCRIPTION "The minimum temperature in tenths of degrees Celsius recorded during the 24 hours
preceding the observation at the height specified by the essTemperatureSensorHeight as specified in the
first row of the essTemperatureTable. The value 1001 shall indicate an error condition or missing value."
REFERENCE "Resolution is based on WMO Binary Code form FM 94 BUFR Table B table reference
descriptor 0 12 012; temperature in kelvin is determined by adding 273.15 to this value."
::= {essNtcipTemperature 6}

                                               
-- Contains objects used to describe the humidity and precipitation data that is collected by the
-- ess.
essBufrPrecip OBJECT IDENTIFIER ::= {essBufr 13 }
essNtcipPrecip OBJECT IDENTIFIER ::= {essNtcip 6 }

                          
essRelativeHumidity OBJECT-TYPE
SYNTAX        INTEGER (0..101)
ACCESS        read-only
STATUS        mandatory


                                                                                                          

                                                                                                        
                                                                                                        

DESCRIPTION "The relative humidity in percent. The value of 101 shall indicate an error condition or
missing value."
REFERENCE "WMO Binary Code form FM 94 BUFR Table B table reference descriptor 0 13 003."
::= {essBufrPrecip 3}

                   
essWaterDepth OBJECT-TYPE
SYNTAX          INTEGER (0..65535)
ACCESS          read-only
STATUS          optional
DESCRIPTION "Indicates the depth of the water from a user defined point in centimeters. The value of
65535 shall indicate an error condition or missing value. This may be used for stream depth, depth of
water over a roadway, reservoir depth, or other such uses."
::= {essNtcipPrecip 1}

                           
essAdjacentSnowDepth OBJECT-TYPE
SYNTAX          INTEGER (0..3001)
ACCESS          read-only
STATUS          mandatory
DESCRIPTION "The depth of snow in centimeters on representative areas other than the highway
pavement, avoiding drifts and plowed areas. The value 3001 shall indicate an error condition or missing
value."
::={ essNtcipPrecip 2}

                          
essRoadwaySnowDepth OBJECT-TYPE
SYNTAX INTEGER (0..3001)
ACCESS read-only
STATUS mandatory
DESCRIPTION "The current depth of unpacked snow in centimeters on the driving surface. The value
3001 shall indicate an error condition or missing value."
::={essNtcipPrecip 3}

                               
essRoadwaySnowPackDepth OBJECT-TYPE
SYNTAX           INTEGER (0..3001)
ACCESS           read-only
STATUS           mandatory
DESCRIPTION "The current depth of packed snow in centimeters on the roadway surface. The value
3001 shall indicate an error condition or missing value."
::={ essNtcipPrecip 4}

                               
essPrecipYesNo OBJECT-TYPE
SYNTAX INTEGER { precip (1),
                       noPrecip (2),
                       error (3)}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates whether or not moisture is detected by the sensor."
::={ essNtcipPrecip 5}

                                            



                                                                                                           

                      
         

essPrecipRate OBJECT-TYPE
SYNTAX           INTEGER (0..65535)
ACCESS           read-only
STATUS           mandatory
DESCRIPTION "The rainfall, or water equivalent of snow, rate in tenths of grams per square meter per
second (for rain, this is approximately to 0.36 mm/hr). A value of 65535 shall indicate an error condition
or missing value."
REFERENCE "WMO Binary Code form FM 94 BUFR Table B table reference descriptor 0 13 014."
::= { essBufrPrecip 14}

                                  
essSnowfallAccumRate OBJECT-TYPE
SYNTAX          INTEGER (0..65535)
ACCESS          read-only
STATUS          mandatory
DESCRIPTION "The snowfall accumulation rate in 10^-7 meters per second (this is equivalent to 0.36
mm/hr). The value 65535 shall indicate an error condition or missing value."
REFERENCE "WMO Binary Code form FM 94 BUFR Table B table reference descriptor 0 13 015."
::= { essBufrPrecip 15}

                               
essPrecipSituation OBJECT-TYPE
SYNTAX          INTEGER { other (1),
                          unknown (2),
                          noPrecipitation (3),
                          unidentifiedSlight (4),
                          unidentifiedModerate (5),
                          unidentifiedHeavy (6),
                          snowSlight (7),
                          snowModerate (8),
                          snowHeavy (9),
                          rainSlight (10),
                          rainModerate (11),
                          rainHeavy (12),
                          frozenPrecipitationSlight (13),
                          frozenPrecipitationModerate (14),
                          frozenPrecipitationHeavy (15)}
ACCESS          read-only
STATUS          mandatory




                                                                                                         

                                                                                                        
                                                                                                        

DESCRIPTION "Describes the weather situation in terms of precipitation. Defined values of intensity are:
         Intensity                                       Meaning
         slight                                          < 2mm/h water equivalent
         moderate                                        >= 2 and < 8 mm/h water equivalent
         heavy                                           >= 8 mm/h water equivalent
If one exists, the corresponding BUFR value is indicated for staffed (BUFRs) and automated (BUFRa)
stations. The indicated value can be found in the BUFR Table referenced below. Defined values are:
         Range            BUFRa         BUFRs            Meaning
         1                                               other
         2                                               unknown
         3                                               no precipitation
         4                                               unidentified slight
         5                                               unidentified moderate
         6                                               unidentified heavy
         7                171           85               snow slight
         8                172           86               snow moderate
         9                173           86               snow heavy
         10                             61               rain slight
         11               165           63               rain moderate
         12               163           65               rain heavy
         13                                              frozen precipitation slight
         14                                              frozen precipitation moderate
         15                                              frozen precipitation heavy"
REFERENCE "The values identified in the above table for BUFRa and BUFRs can be found in WMO
Binary Code form FM 94 BUFR Table B table reference descriptor 0 20 003."
::= { essNtcipPrecip 6}

                              
essIceThickness OBJECT-TYPE
SYNTAX          INTEGER (0..65535)
ACCESS          read-only
STATUS          optional
DESCRIPTION "Indicates the thickness of the ice in millimeters. The value 65535 shall indicate an error
condition or missing value."
::= {essNtcipPrecip 7}

                               
essPrecipitationStartTime OBJECT-TYPE
SYNTAX           INTEGER (0..4294967295)
ACCESS           read-only
STATUS           mandatory
DESCRIPTION "The time at which the most recent precipitation event began, measured in seconds since
00:00:00 January 1, 1970 UTC. As this standard has been developed long after 1970, a value of 0 for
the time should indicate to the management station that the data received is suspect."
::= { essNtcipPrecip 8}

                             
essPrecipitationEndTime OBJECT-TYPE
SYNTAX            INTEGER (0..4294967295)
ACCESS            read-only
STATUS            mandatory
DESCRIPTION "The time at which the most recently completed precipitation event ended, measured in
seconds since 00:00:00 January 1, 1970 UTC. As this standard has been developed long after 1970, a
value of 0 for the time should indicate to the management station that the data received is suspect."
::= { essNtcipPrecip 9}


                                                                                                           

                      
         



                                        
essPrecipitationOneHour OBJECT-TYPE
SYNTAX           INTEGER (0..65535)
ACCESS           read-only
STATUS           mandatory
DESCRIPTION "The total water equivalent precipitation over the hour preceding the observation in tenths
of kilograms per square meter (for rain, this is approximately tenths of millimeters). A value of 65535
shall indicate an error condition or missing value."
REFERENCE "WMO Binary Code form FM 94 BUFR Table B table reference descriptor 0 13 019."
::= { essBufrPrecip 19}

                                           
essPrecipitationThreeHours OBJECT-TYPE
SYNTAX           INTEGER (0..65535)
ACCESS           read-only
STATUS           mandatory
DESCRIPTION "The total water equivalent precipitation over the three hours preceding the observation in
tenths of kilograms per square meter (for rain, this is approximately tenths of millimeters). A value of
65535 shall indicate an error condition or missing value."
REFERENCE "WMO Binary Code form FM 94 BUFR Table B table reference descriptor 0 13 020."
::= { essBufrPrecip 20}

                                         
essPrecipitationSixHours OBJECT-TYPE
SYNTAX           INTEGER (0..65535)
ACCESS           read-only
STATUS           mandatory
DESCRIPTION "The total water equivalent precipitation over the six hours preceding the observation in
tenths of kilograms per square meter (for rain, this is approximately tenths of millimeters). A value of
65535 shall indicate an error condition or missing value."
REFERENCE "WMO Binary Code form FM 94 BUFR Table B table reference descriptor 0 13 021."
::= { essBufrPrecip 21}

                                            
essPrecipitationTwelveHours OBJECT-TYPE
SYNTAX            INTEGER (0..65535)
ACCESS            read-only
STATUS            mandatory
DESCRIPTION "The total water equivalent precipitation over the twelve hours preceding the observation
in tenths of kilograms per square meter (for rain, this is approximately to tenths of millimeters). A value
of 65535 shall indicate an error condition or missing value."
REFERENCE "WMO Binary Code form FM 94 BUFR Table B table reference descriptor 0 13 022."
::= { essBufrPrecip 22}

                                                 
essPrecipitation24Hours OBJECT-TYPE
SYNTAX           INTEGER (0..65535)
ACCESS           read-only
STATUS           mandatory
DESCRIPTION "The total water equivalent precipitation over the twenty-four hours preceding the
observation in tenths of kilograms per square meter (for rain, this is equivalent to tenths of millimeters).
A value of 65535 shall indicate an error condition or missing value."




                                                                                                           

                                                                                                               
                                                                                                               

REFERENCE "WMO Binary Code form FM 94 BUFR Table B table reference descriptor 0 13 023."
::= { essBufrPrecip 23}

                         
-- Contains objects used to describe the data that is collected by the pavement surface sensor.
essBufrRadiation OBJECT IDENTIFIER ::= {essBufr 14 }
essNtcipRadiation OBJECT IDENTIFIER ::= {essNtcip 7}

                          
essSolarRadiation OBJECT-TYPE
SYNTAX          INTEGER (0..65535)
ACCESS          read-only
STATUS          mandatory
DESCRIPTION "The direct solar radiation integrated over the 24 hours preceding the observation in
Joules per square meter. A value of 65535 shall indicate a missing value."
REFERENCE "WMO Binary Code form FM 94 BUFR Table B table reference descriptor 0 14 024."
::= {essBufrRadiation 24}

                    
essTotalSun OBJECT-TYPE
SYNTAX          INTEGER (0..1441)
ACCESS          read-only
STATUS          mandatory
DESCRIPTION "The total amount of sunshine in minutes over the 24 hour period preceding the
observation. A value of 1441 shall indicate a missing value."
REFERENCE "WMO Binary Code form FM 94 BUFR Table B table reference descriptor 0 14 031."
::= {essBufrRadiation 31}

                               
essCloudSituation OBJECT-TYPE
SYNTAX           INTEGER { overcast (1),
                                cloudy (2),
                                partlyCloudy (3),
                                mostlyClear (4),
                                clear (5)}
ACCESS           read-only
STATUS           mandatory
DESCRIPTION "Describes the amount of cloud cover. The associated percentages of cloud cover are
indicated to identify the differences between the defined values. Defined values are:
        Value                       Meaning               Percent Cloud Cover
        1                           Overcast              100 %
        2                           Mostly cloudy         62.5 % - 99 %
        3                           Partly cloudy         37.5 % - 62.4 %
        4                           Mostly sunny          1 % - 37.4 %
        5                           Clear skies           0 %"
::= {essNtcipRadiation 1}

                            
-- Contains objects used to describe the visibility data that is collected by the ess.
essNtcipVisibility OBJECT IDENTIFIER ::= {essNtcip 8 }

                           
essVisibility OBJECT-TYPE



                                                                                                                

                      
         

SYNTAX           INTEGER (0..1000001)
ACCESS           read-only
STATUS           mandatory
DESCRIPTION "Surface visibility measured in one tenth of a meter. The value 1000001 shall indicate an
error condition or missing value."
REFERENCE "The value for WMO Binary Code form FM 94 BUFR Table B table reference descriptor 0
20 001 is given by this value divided by 100."
::= { essNtcipVisibility 1}

                           
essVisibilitySituation OBJECT-TYPE
SYNTAX            INTEGER { other (1),
                              unknown (2),
                              clear (3),
                              fogNotPatchy (4),
                              patchyFog (5),
                              blowingSnow (6),
                              smoke (7),
                              seaSpray (8),
                              vehicleSpray (9),
                              blowingDustOrSand (10),
                              sunGlare (11),
                              swarmsOfInsects (12)}
ACCESS            read-only
STATUS            mandatory
DESCRIPTION "Describes the travel environment in terms of visibility. If one exists, the corresponding
BUFR value is indicated for staffed (BUFRs) and automated (BUFRa) stations. The indicated value can
be found in the BUFR Table referenced below. Defined values are:
        Range              BUFRs         BUFRa        Meaning
        1                                             other visibility anomaly
        2                                             unknown
        3                  0             100          clear
        4                  44            130          Fog - not patchy
        5                  41            131          Patchy fog
        6                  36            127          Blowing snow
        7                  04            104          Smoke
        8                  07            207          Sea Spray
        9                                             Vehicle Spray
        10                 31            127          Blowing dust or sand
        11                                            sun glare
        12                                            Swarms of insects"
REFERENCE "The values identified in the above table for BUFRa and BUFRs can be found in WMO
Binary Code form FM 94 BUFR Table B table reference descriptor 0 20 003."
::= {essNtcipVisibility 3}

                            
-- Contains objects used to describe the data that is collected by the pavement surface sensor.
essNtcipPavement OBJECT IDENTIFIER ::= {essNtcip 9}

                                 
numEssPavementSensors OBJECT-TYPE
SYNTAX      INTEGER (0..255)
ACCESS      read-only
STATUS      mandatory



                                                                                                        

                                                                                                       
                                                                                                       

DESCRIPTION "Indicates the number of entries in the pavement sensor table."
::= {essNtcipPavement 1}

                            
essPavementSensorTable OBJECT-TYPE
SYNTAX          SEQUENCE OF EssPavementSensorEntry
ACCESS          not-accessible
STATUS          mandatory
DESCRIPTION "Table containing the pavement sensor data fields."
::= {essNtcipPavement 2}

essPavementSensorEntry OBJECT-TYPE
SYNTAX        EssPavementSensorEntry
ACCESS        not-accessible
STATUS        mandatory
DESCRIPTION "Parameters for specific pavement sensor data fields."
INDEX {essPavementSensorIndex}
::= {essPavementSensorTable 1}

EssPavementSensorEntry ::= SEQUENCE {
      essPavementSensorIndex                           INTEGER,
      essPavementSensorLocation                        DisplayString,
      essPavementType                                  INTEGER,
      essPavementElevation                             INTEGER,
      essPavementExposure                              INTEGER,
      essPavementSensorType                            INTEGER,
      essSurfaceStatus                                 INTEGER,
      essSurfaceTemperature                            INTEGER,
      essPavementTemperature                           INTEGER,
      essSurfaceWaterDepth                             INTEGER,
      essSurfaceSalinity                               INTEGER,
      essSurfaceConductivity                           INTEGER,
      essSurfaceFreezePoint                            INTEGER,
      essSurfaceBlackIceSignal                         INTEGER,
      essPavementSensorError                           INTEGER}

                              
essPavementSensorIndex OBJECT-TYPE
SYNTAX        INTEGER (1..255)
ACCESS        read-only
STATUS        mandatory
DESCRIPTION "Enumerated list of row entries that will provide surface sensor data."
::= {essPavementSensorEntry 1}

                                 
essPavementSensorLocation OBJECT-TYPE
SYNTAX         DisplayString (SIZE (0..255))
ACCESS         read-write
STATUS         mandatory
DESCRIPTION "A textual string indicating the location of the pavement sensor."
::= { essPavementSensorEntry 2}

-- We have contacted the LRMS group to express a need for a better mechanism for
-- defining this location down to the lane level.



                                                                                                          

                      
         

                      
essPavementType OBJECT-TYPE
SYNTAX         INTEGER { other (1),
                          unknown (2),
                          asphalt (3),
                          openGradedAsphalt (4),
                          concrete (5),
                          steelBridge (6),
                          concreteBridge (7),
                          asphaltOverlayBridge (8),
                          timberBridge (9) }
ACCESS         read-write
STATUS         mandatory
DESCRIPTION "Indicates the type of pavement on the roadway.
other                     a different type of bridge deck
unknown                   the data was never recorded in the system
asphalt                   asphalt pavement on ground
concrete                  concrete pavement on ground
steelBridgeconcrete       a concrete driving surface on a steel girder bridge
steelBridgeAsphalt        an asphalt driving surface on a steel girder bridge
steelBridge               a steel lattice driving surface on the bridge
concreteBridge            a concrete driving surface on a concrete bridge
concreteBridgeAsphalt     an asphalt overlay driving surface on a concrete bridge
timberBridge              a wooden deck driving surface on the bridge"
::= { essPavementSensorEntry 3}

                           
essPavementElevation OBJECT-TYPE
SYNTAX         INTEGER (-1000..1001)
ACCESS         read-only
STATUS         mandatory
DESCRIPTION "The elevation of the street surface in meters with respect to the essReferenceHeight.
The value 1001 shall indicate a missing value."
::= { essPavementSensorEntry 4}

                          
essPavementExposure OBJECT-TYPE
SYNTAX           INTEGER (0..101)
ACCESS           read-write
STATUS           mandatory
DESCRIPTION "Indicates a very rough percentage of the solar energy which will directly hit the sensor.
A value of 100 indicates a fully visible sky. A value of 101 shall indicate a missing value."
::= { essPavementSensorEntry 5}

                             
essPavementSensorType OBJECT-TYPE
SYNTAX       INTEGER {other (1),
                       contactPassive (2),
                       contactActive (3),
                       infrared (4),
                       radar (5),
                       vibrating (6),
                       microwave (7)}
ACCESS       read-only



                                                                                                      

                                                                                                    
                                                                                                    

STATUS         mandatory
DESCRIPTION "A value indicating the type of pavement sensor."
::= { essPavementSensorEntry 6}

                       
essSurfaceStatus OBJECT-TYPE
SYNTAX         INTEGER { other (1),
                         error (2),
                         dry (3),
                         traceMoisture (4),
                         wet (5),
                         chemicallyWet (6),
                         iceWarning (7),
                         iceWatch (8),
                         snowWarning (9),
                         snowWatch (10),
                         absorption (11),
                         dew (12),
                         frost (13),
                         absorptionAtDewpoint (14) }
ACCESS         read-only
STATUS         mandatory
DESCRIPTION "A value indicating the pavement surface status."
::= { essPavementSensorEntry 7}

                            
essSurfaceTemperature OBJECT-TYPE
SYNTAX           INTEGER (-1000..1001)
ACCESS           read-only
STATUS           mandatory
DESCRIPTION "The current pavement surface temperature in tenths of degrees Celsius. The value
1001 shall indicate an error condition or missing value."
::= { essPavementSensorEntry 8}

                             
essPavementTemperature OBJECT-TYPE
SYNTAX         INTEGER (-1000..1001)
ACCESS         read-only
STATUS         optional
DESCRIPTION "The current pavement temperature 2-10 cm below the pavement surface in tenths of
degrees Celsius. The value 1001 shall indicate an error condition or missing value."
::= { essPavementSensorEntry 9}

                             
essSurfaceWaterDepth OBJECT-TYPE
SYNTAX           INTEGER (0..255)
ACCESS           read-only
STATUS           optional
DESCRIPTION "The current depth of water on the surface of the roadway measured in millimeters. The
value 255 shall indicate an error condition or missing value."
::= { essPavementSensorEntry 10}

                          
essSurfaceSalinity OBJECT-TYPE



                                                                                                       

                      
         

SYNTAX           INTEGER (0..65535)
ACCESS           read-only
STATUS           optional
DESCRIPTION "The pavement salinity in parts per one hundred thousand. The value 65535 shall
indicate an error condition or missing value."
::= { essPavementSensorEntry 11}

-- A comment has been received to make both the surface salinity and surface conductivity optional
-- objects. This issue will be discussed by the WG with any other comments received during balloting.

                              
essSurfaceConductivity OBJECT-TYPE
SYNTAX          INTEGER (0..65535)
ACCESS          read-only
STATUS          optional
DESCRIPTION "Indicates the conductance of the ice/liquid mixture on the pavement as detected by the
sensor, in mhos, which is the inverse of ohms. The value 65535 shall indicate an error condition or
missing value."
::= { essPavementSensorEntry 12}

                                 
essSurfaceFreezePoint OBJECT-TYPE
SYNTAX           INTEGER (-1000..1001)
ACCESS           read-only
STATUS           optional
DESCRIPTION "The temperature in tenths of degrees Celsius at which the existing solution on the
roadway will freeze. The value 1001 shall indicate an error condition or missing value."
::= { essPavementSensorEntry 13}

                                  
essSurfaceBlackIceSignal OBJECT-TYPE
SYNTAX         INTEGER {other (1),
                         noIce (2),
                         blackIce (3),
                         detectorError (4) }
ACCESS         read-only
STATUS         optional
DESCRIPTION "A value indicating if Black Ice is detected by the sensor."
::= { essPavementSensorEntry 14}

                              
essPavementSensorError OBJECT-TYPE
SYNTAX         INTEGER {other (1),
                         none (2),
                         noResponse (3),
                         cutCable (4),
                         shortCircuit (5),
                         dirtyLens (6) }
ACCESS         read-only
STATUS         mandatory
DESCRIPTION "A value indicating the type of pavement sensor error."
::= { essPavementSensorEntry 15}

                                    



                                                                                                       

                                                                                                         
                                                                                                         

numEssSubSurfaceSensors OBJECT-TYPE
SYNTAX          INTEGER (0..255)
ACCESS          read-only
STATUS          mandatory
DESCRIPTION "Indicates the number of entries in the Sub-Surface Sensor Table."
::= {essNtcipPavement 3}

                               
essSubSurfaceSensorTable OBJECT-TYPE
SYNTAX          SEQUENCE OF EssSubSurfaceSensorEntry
ACCESS          not-accessible
STATUS          mandatory
DESCRIPTION "Table containing the surface sensor data fields."
::= {essNtcipPavement 4}

essSubSurfaceSensorEntry OBJECT-TYPE
SYNTAX         EssSubSurfaceSensorEntry
ACCESS         not-accessible
STATUS         mandatory
DESCRIPTION "Parameters for specific sub-surface sensor data fields."
INDEX {essSubSurfaceSensorIndex}
::= {essSubSurfaceSensorTable 1}

EssSubSurfaceSensorEntry ::= SEQUENCE {
      essSubSurfaceSensorIndex                          INTEGER,
      essSubSurfaceSensorLocation                       DisplayString,
      essSubSurfaceType                                 INTEGER,
      essSubSurfaceSensorDepth                          INTEGER,
      essSubSurfaceTemperature                          INTEGER,
      essSubSurfaceMoisture                             INTEGER,
      essSubSurfaceSensorError                          INTEGER}

                                 
essSubSurfaceSensorIndex OBJECT-TYPE
SYNTAX          INTEGER (1..255)
ACCESS          read-only
STATUS          mandatory
DESCRIPTION "Enumerated list of row entries that will provide surface sensor data."
::= { essSubSurfaceSensorEntry 1}

                                    
essSubSurfaceSensorLocation OBJECT-TYPE
SYNTAX          DisplayString (SIZE (0..255))
ACCESS          read-write
STATUS          mandatory
DESCRIPTION "A textual string indicating the location of the subsurface sensor."
::= { essSubSurfaceSensorEntry 2}

                         
essSubSurfaceType OBJECT-TYPE
SYNTAX        INTEGER {other (1),
                       unknown (2),
                       concrete (3),
                       asphalt (4),
                       openGradedAsphalt (5),


                                                                                                           

                      
         

                             gravel (6),
                             clay (7),
                             loam (8),
                             sand (9),
                             permafrost (10),
                             variousAggregates (11),
                             air (12)}
ACCESS          read-write
STATUS          mandatory
DESCRIPTION "Indicates the type of sub-surface. A value of air would indicate a bridge."
::= { essSubSurfaceSensorEntry 3}

                                 
essSubSurfaceSensorDepth OBJECT-TYPE
SYNTAX           INTEGER (0..1001)
ACCESS           read-write
STATUS           mandatory
DESCRIPTION "Depth of sub-surface sensor in centimeters below the pavement surface. The value
1001 shall indicate an error condition or missing value."
::= { essSubSurfaceSensorEntry 4}

                                
essSubSurfaceTemperature OBJECT-TYPE
SYNTAX           INTEGER (-1000..1001)
ACCESS           read-only
STATUS           mandatory
DESCRIPTION "The current sub-surface temperature in tenths of degrees Celsius. The value 1001 shall
indicate an error condition or missing value."
::= { essSubSurfaceSensorEntry 5}

                             
essSubSurfaceMoisture OBJECT-TYPE
SYNTAX          INTEGER (0..101)
ACCESS          read-only
STATUS          optional
DESCRIPTION "The sub-surface moisture expressed as a percentage (eg. 0 indicates dry, 100 indicates
saturated). The value 101 indicates an error condition or missing value"
::= { essSubSurfaceSensorEntry 7}

                                 
essSubSurfaceSensorError OBJECT-TYPE
SYNTAX          INTEGER {other (1),
                          none (2),
                          noResponse (3),
                          cutCable (4),
                          shortCircuit (5)}
ACCESS          read-only
STATUS          mandatory
DESCRIPTION "A value indicating the type of sensor error."
::= { essSubSurfaceSensorEntry 8}

                            
-- This node contains objects which have been developed to facilitate experiments with data that collected
-- by mobile platforms (e.g., specially equipped maintenance vehicles).


                                                                                                        

                                                                                                         
                                                                                                         

-- There has been limited use of mobile ESS platforms within the surface transportation industry and as
-- such these objects should be considered experimental.
-- It is expected that mobile platforms will use the objects defined above plus these objects.
essNtcipMobile OBJECT IDENTIFIER ::= {essNtcip 10}

                      
essMobileFriction OBJECT-TYPE
SYNTAX           INTEGER (0..101)
ACCESS           read-only
STATUS           mandatory
DESCRIPTION "Indicates measured coefficient of friction in percent. The value 101 shall indicate an
error condition or missing value."
::= { essNtcipMobile 1}

                                                     
essMobileObservationGroundState OBJECT-TYPE
SYNTAX          INTEGER {other (1),
                            dry (2),
                            moist (3),
                            wet (4),
                            flooded (5),
                            frozen (6),
                            glaze (7),
                            dustySandy (8),
                            veryDry (9),
                            icy (10),
                            patchyWetSnow (11),
                            moderateWetSnowCover (12),
                            fullWetSnowCover (13),
                            patchyDrySnow (14),
                            moderateDrySnowCover (15),
                            fullDrySnowCover (16),
                            driftingSnow (17),
                            unknown (18)}
ACCESS          read-only
STATUS          mandatory
DESCRIPTION "The prevailing observed ground state of the surrounding environment as determined by
the observer. This is an indicator of past weather conditions."
::= { essNtcipMobile 2}

                                   
essMobileObservationPavement OBJECT-TYPE
SYNTAX        INTEGER {other (1),
                        dry (2),
                        wet (3),
                        puddles (4),
                        shallowStandingWater (5),
                        shallowFlowingWater (6),
                        deepStandingWater (7),
                        deepFlowingWater (8),
                        dustingFreshSnow (9),
                        moderateFreshSnow (10),
                        deepFreshSnow (11),
                        plowedSnow (12),
                        slush (13),


                                                                                                            

                      
         

                             packedSnowPatches (14),
                             packedSnow (15),
                             lightSnowDrifts (16),
                             moderateSnowDrifts (17),
                             heavySnowDrifts (18),
                             frost (19),
                             icePatches (20),
                             moderatelyIcy (21),
                             heavyIcing (22),
                             blackIce (23),
                             sheetIce (24),
                             frozenSlush (25) }
ACCESS          read-only
STATUS          mandatory
DESCRIPTION "The prevailing observed conditions on the driving surface as determined by the
observer."
::= { essNtcipMobile 3}

                               
-- This node contains objects which have been developed to monitor the various types and amounts of
-- treatments that are spread on the pavement surface.
essNtcipTreatment OBJECT IDENTIFIER ::= { essNtcip 11 }

                           
numEssTreatments OBJECT-TYPE
SYNTAX          INTEGER (0..255)
ACCESS          read-only
STATUS          mandatory
DESCRIPTION "Indicates the number of entries in the Pavement Treatment Table."
::= {essNtcipTreatment 1}

                               
essPavementTreatmentTable OBJECT-TYPE
SYNTAX          SEQUENCE OF EssPavementTreatmentEntry
ACCESS          not-accessible
STATUS          mandatory
DESCRIPTION "Table containing the pavement treatment data fields."
::= {essNtcipTreatment 2}

essPavementTreatmentEntry OBJECT-TYPE
SYNTAX        EssPavementTreatmentEntry
ACCESS        not-accessible
STATUS        mandatory
DESCRIPTION "Parameters for specific pavement treatment data fields."
INDEX {essPavementTreatmentIndex}
::= {essPavementTreatmentTable 1}

EssPavementTreatmentEntry ::= SEQUENCE {
      essPavementTreatmentIndex                         INTEGER,
      essPaveTreatProductType                           INTEGER,
      essPaveTreatProductForm                           INTEGER,
      essPercentProductMix                              INTEGER}

                                 
essPavementTreatmentIndex OBJECT-TYPE


                                                                                                     

                                                                                                          
                                                                                                          

SYNTAX         INTEGER (1..255)
ACCESS         read-only
STATUS         mandatory
DESCRIPTION "Enumerated list of row entries that will provide pavement treatment data."
::= { essPavementTreatmentEntry 1}

                                        
essPaveTreatProductType OBJECT-TYPE
SYNTAX           INTEGER {other (1),
                             sand (2),
                             dirt (3),
                             gravel (4),
                             cinders (5),
                             water (6),
                             enhancedSalts (7),
                             naCl (8),
                             caCl (9),
                             mgCl (10),
                             cMA (11),
                             kAC (12),
                             naFormate (13),
                             naA (14) }
ACCESS           read-only
STATUS           mandatory
DESCRIPTION "Indicates the type of treatment being applied to the road. An enhanced definition of
some of the values are as follows:
other - any other type of treatment
water - used as a diluting agent
cMA - Calcium-Magnesium Acetate
kAC - Potassium-Magnesium Acetate
naFormate - Sodium Formate
naA - Sodium Acetate"
::= { essPavementTreatmentEntry 2}

                               
essPaveTreatProductForm OBJECT-TYPE
SYNTAX         INTEGER { other (1),
                          dry (2),
                          prewet (3),
                          liquid (4)}
ACCESS         read-only
STATUS         mandatory
DESCRIPTION "Indicates the condition of the treatment being applied to the road."
::= { essPavementTreatmentEntry 3}

                                            
essPercentProductMix OBJECT-TYPE
SYNTAX           INTEGER (0..100)
ACCESS           read-only
STATUS           mandatory
DESCRIPTION "Indicates the percentage of the total application mix by weight that is of the type
specified in essPaveTreatProductType. The sum of these percentages within the total mixture shall
equal 100."
::= { essPavementTreatmentEntry 4}



                                                                                                          

                      
         

                       
essPaveTreatmentAmount OBJECT-TYPE
SYNTAX           INTEGER (0..255)
ACCESS           read-only
STATUS           mandatory
DESCRIPTION "Indicates quantity of the treatment being applied in kilograms per lane kilometer."
::= { essNtcipTreatment 3}

                      
essPaveTreatmentWidth OBJECT-TYPE
SYNTAX           INTEGER (0..255)
ACCESS           read-only
STATUS           mandatory
DESCRIPTION "Indicates the width of the spread of treatment in meters."
::= { essNtcipTreatment 4}

                           
essNtcipAirQuality OBJECT IDENTIFIER ::= { essNtcip 12 }
-- This node contains objects used for monitoring air quality conditions.

-- A comment has been received to add error conditions to these objects as per previous objects. This
-- was the original intent and this modification will be discussed by the WG along with any other
comments
-- received during balloting.

                                
essCO OBJECT-TYPE
SYNTAX           INTEGER (0..255)
ACCESS           read-only
STATUS           mandatory
DESCRIPTION "The concentration of carbon monoxide in the air, measured in parts per million. The
value 255 shall indicate an error condition or missing value."
::= {essNtcipAirQuality 1}

                               
essCO2 OBJECT-TYPE
SYNTAX          INTEGER (0..65535)
ACCESS          read-only
STATUS          mandatory
DESCRIPTION "The concentration of carbon dioxide in the air, measured in parts per billion. The value
65535 shall indicate an error condition or missing value."
::= {essNtcipAirQuality 2}

                              
essNO OBJECT-TYPE
SYNTAX           INTEGER (0..255)
ACCESS           read-only
STATUS           mandatory
DESCRIPTION "The concentration of nitrous oxide in the air, measured in parts per million. The value
255 shall indicate an error condition or missing value."
::= {essNtcipAirQuality 3}

                                 



                                                                                                      

                                                                                                        
                                                                                                        

essNO2 OBJECT-TYPE
SYNTAX           INTEGER (0..255)
ACCESS           read-only
STATUS           mandatory
DESCRIPTION "The concentration of nitrogen dioxide in the air, measured in parts per billion. The value
255 shall indicate an error condition or missing value."
::= {essNtcipAirQuality 4}

                               
essSO2 OBJECT-TYPE
SYNTAX          INTEGER (0..65535)
ACCESS          read-only
STATUS          mandatory
DESCRIPTION "The concentration of sulfur dioxide in the air, measured in parts per billion. The value
65535 shall indicate an error condition or missing value."
::= {essNtcipAirQuality 5}

                      
essO3 OBJECT-TYPE
SYNTAX           INTEGER (0..255)
ACCESS           read-only
STATUS           mandatory
DESCRIPTION "The concentration of ozone in the air, measured in parts per one hundred billion. The
value 255 shall indicate an error condition or missing value."
::= {essNtcipAirQuality 6}

                                   
essPM10 OBJECT-TYPE
SYNTAX          INTEGER (0..65535)
ACCESS          read-only
STATUS          mandatory
DESCRIPTION "The concentration of small particulate matter of 10 micrometers or less in diameter in the
air, measured in micrograms per cubic meter. The value 65535 shall indicate an error condition or
missing value."
::= {essNtcipAirQuality 7}

                             
essNtcipWaterQuality OBJECT IDENTIFIER ::= { essNtcip 13 }
-- This node contains objects used for monitoring water quality conditions. Appropriate agencies have
-- been contacted to assist in the development of these objects for future versions.

END