-- OIDref derived MIB transcription. Original PDF: https://www.ite.org/ITEORG/assets/File/Standards/1201v4-0-0.pdf -- Publisher front matter and notices follow as comments. -- A Joint Standard of AASHTO, ITE, and NEMA -- -- -- -- -- NTCIP 1201 v4.0.0 -- -- -- National Transportation -- Communications for ITS Protocol -- Global Object (GO) Definitions -- -- -- Published June 2025 -- -- -- -- -- Published by: -- -- American Association of State Highway and Transportation Officials (AASHTO) -- 555 12th Street, N.W., Suite 1000 -- Washington, D.C. 20004 -- -- Institute of Transportation Engineers (ITE) -- 1627 I Street, N.W., Suite 550 -- Washington, D.C. 20006 -- -- National Electrical Manufacturers Association (NEMA) -- 1300 17th Street N, #900 -- Arlington, VA 22209 -- -- -- --  2025 AASHTO / ITE / NEMA. All rights reserved. -- -- -- NOTICES -- -- Copyright Notice -- -- © 1997, 1999, 2005, 2011, 2025 by the American Association of State Highway and Transportation -- Of f icials (AASHTO), the Institute of Transportation Engineers (ITE), and the National Electrical -- Manuf acturers Association (NEMA). All intellectual property rights, including, but not limited to, the rights -- of reproduction, translation, and display are reserved under the laws of the United States of America, the -- Universal Copyright Convention, the Berne Convention, and the International and Pan American -- Copyright Conventions. Except as licensed or permitted, you may not copy these materials without prior -- written permission f rom AASHTO, ITE, or NEMA. Use of these materials does not grant any rights of -- ownership or claim of copyright. -- -- Visit www.ntcip.org For additional copyright inf ormation, instructions on requesting reprints of excerpts, -- and requests f or reproduction d the beyond the permissions granted below, visit www.ntcip.org. -- -- PDF File License Agreement -- -- To the extent that these materials are distributed by AASHTO / ITE / NEMA in the f orm of an Adobe® -- Portable Document Format (PDF) electronic f ile (the PDF f ile), AASHTO / ITE / NEMA authorizes each -- registered user to view, download, copy, or print the f ile f rom the authorized website, subject to the terms -- and conditions of this license agreement: -- -- a) You may download one copy of the PDF f ile f or personal, noncommercial, and intraorganizational -- use only. -- b) Ownership of the PDF f ile is not transf erred to you; you are licensed to use the PDF f ile. -- c) You may make one additional electronic copy of the PDF f ile, such as to a secondary hard drive -- or CD. -- d) You agree not to copy, distribute, or transf er the PDF f ile f rom that media to any other electronic -- media or device. -- e) You may print one paper copy of the PDF f ile. -- f ) You may make one paper reproduction of the printed copy. -- g) Any permitted copies must retain the copyright notice and all proprietary notices. -- h) The PDF f ile license does not include (1) resale of the PDF f ile or copies, (2) republishing the -- content in compendiums or anthologies, (3) publishing excerpts in commercial publications or -- works f or hire, (4) editing or modif ication of the PDF f ile except those portions as permitted, (5) -- posting on network servers or distribution by e- mail or f rom electronic storage devices, and (6) -- translation to other languages or conversion to other electronic f ormats. -- i) Other use of the PDF f ile and printed copy requires express, prior written consent. -- -- -- Data Dictionary and MIB Distribution Permission -- -- To the extent that these materials are distributed by AASHTO / ITE / NEMA in the f orm of a Data -- Dictionary ("DD") or Management Inf ormation Base ("MIB"), AASHTO / ITE / NEMA extend the f ollowing -- permission: -- -- You may make or distribute unlimited copies, in part or f ull, of the DD or MIB, including copies f or -- commercial distribution, provided that: -- -- 1. Each copy you make or distribute includes the citation "From NTCIP 0000 [insert the standard -- number]. Copyright by AASHTO / ITE / NEMA. Used by permission." -- 2. The copies are not edited f rom the published version of this document. -- -- These materials are delivered "AS IS," without any warranties regarding their use or perf ormance. -- -- AASHTO / ITE / NEMA and their suppliers do not warrant the performance or results you may -- obtain by using these materials. AASHTO / ITE / NEMA and their suppliers make no warranties, -- express or implied, as to noninfringement of third-party rights, merchantability, or fitness for any -- particular purpose. In no event will AASHTO / ITE / NEMA or their suppliers be liable to you or any -- third party for any claim or for any consequential, incidental or special damages, including any -- lost profits or lost savings, arising from your reproduction or use of these materials, even if an -- AASHTO / ITE / NEMA representative has been advised of the possibility of such damages. -- -- Some states or jurisdictions do not allow the exclusion or limitation of incidental, consequential, or special -- damages, or the exclusion of implied warranties, so the above limitations may not apply to a given user. -- -- Use of these materials does not constitute an endorsement or af f iliation by or between AASHTO, ITE, or -- NEMA and the user, the user's company, or the products and services of the user's company. -- -- If the user is unwilling to accept the f oregoing restrictions, he or she should immediately return these -- materials. -- -- Content and Liability Disclaimer -- -- The inf ormation in this publication was considered technically sound by the consensus of persons -- engaged in the development and approval of the document at the time it was developed. However, -- consensus does not imply unanimous agreement. among every person participating in the development -- of this document. -- -- AASHTO, ITE, and NEMA standards and guideline publications, of which the document contained herein -- is one, are developed through a voluntary consensus standards development process. This process -- brings together volunteers and seeks out the views of persons who have an interest in the topic covered -- by this publication. While AASHTO, ITE, and NEMA administer the process and establish rules to -- promote f airness in the development of consensus, they do not write the document and they do not -- independently test, evaluate, or verif y the accuracy or completeness of any inf ormation or the soundness -- of any judgments contained in their standards and guideline publications. -- -- AASHTO, ITE, and NEMA disclaim liability f or any personal injury, property, or other damages of any -- nature whatsoever, whether special, indirect, consequential, or compensatory, directly or indirectly -- resulting f rom the publication, use of , application, or reliance on this document. AASHTO, ITE, and NEMA -- disclaim and make no guaranty or warranty, express or implied, as to the accuracy or completeness of -- any inf ormation published herein and disclaims and makes no warranty that the inf ormation in this -- document will f ulf ill any of your purposes or needs. AASHTO, ITE, and NEMA do not undertake to -- guarantee the perf ormance of any individual manuf acturer or seller's products or services by virtue of this -- standard or guide. -- -- In publishing and making this document available, AASHTO, ITE, and NEMA are not undertaking to -- render prof essional or other services f or or on behalf of any person or entity, nor are AASHTO, ITE, and -- NEMA undertaking to perf orm any duty owed by any person or entity to someone else. Anyone using this -- document should rely on his or her own independent judgment or, as appropriate, seek the advice of a -- competent prof essional in determining the exercise of reasonable care in any given circumstance. -- Inf ormation and other standards on the topic covered by this publication may be available f rom other -- sources, which the user may wish to consult f or additional views or inf ormation not covered by this -- publication. -- -- AASHTO, ITE, and NEMA have no power, nor do they undertake to police or enf orce compliance with the -- contents of this document. AASHTO, ITE, and NEMA do not certif y, test, or inspect products, designs, or -- -- installations f or saf ety or health purposes. Any certif ication or other statement of compliance with any -- health or saf ety-related inf ormation in this document shall not be attributable to AASHTO, ITE, or NEMA -- and is solely the responsibility of the certif ier or maker of the statement. -- -- Trademark Notice -- -- NTCIP is a trademark of AASHTO / ITE / NEMA. All other trademarks mentioned in this standard belong -- to their respective owners. -- -- -- NTCIP 1201 v4.0.0 -- Page i -- -- -- -- ACKNOWLEDGEMENTS -- -- NTCIP 1201 v04 was prepared by the NTCIP Base Standards and Prof iles Working Group (BSP2 WG), a -- subdivision of the Joint Committee on the NTCIP. This committee operates under a Memorandum of -- Understanding among the American Association of State Highway and Transportation Of f icials -- (AASHTO), the Institute of Transportation Engineers (ITE), and the National Electrical Manuf acturers -- Association (NEMA). The Joint Committee on the NTCIP consists of six representatives f rom each -- standards development organization (SDO) and provides guidance f or NTCIP development. -- -- When this document was prepared, the f ollowing individuals were members of BSP2 WG: -- -- 1. Doug Crawf ord (Chair) 8. Robert Lopes -- 2. Steve Bostrom 9. Alex Mousadi -- 3. Wolf gang Buckel 10. Satya Muthuswamy -- 4. Michael Forbis 11. Bob Rausch -- 5. Joe Gorman 12. Rodney Schilling -- 6. Terry Haukom 13. Shea Tomsin -- 7. Patrick Leung 14. Walt Townsend -- -- -- Other individuals providing input include the f ollowing: -- -- 1. Md Ashraf Ahmed 18. Stephane Lapierre -- 2. Justin Anderson 19. Christopher Lyons -- 3. Kingsley Azubike 20. Gary Molnar -- 4. Ralph Boaz 21. Keith Patton -- 5. Russ Brookshire 22. Mahesh Pawar -- 6. Patrick Chan 23. Frank Perry -- 7. Stan Chow 24. Nu Rosenbohm -- 8. Deborah Curtis 25. Jay Schultz -- 9. Dustin DeVoe 26. Kellen Shain -- 10. Brian Doherty 27. Douglas Tarico -- 11. Edward Fok 28. Nicola Tavares -- 12. Sai Kiran Golla 29. John Thai -- 13. Jacob Grivette 30. Andrew Valdez -- 14. Mohammad Iraki 31. Kenneth Vaughn -- 15. Haydar Issa 32. Sankeer Vulupala -- 16. Denver Kruse 33. Robert White -- 17. AJ Lahiri -- -- -- In addition to the many volunteer ef f orts, recognition is also given to those organizations that supported -- the ef f orts of BSP2 WG by providing comments and f unding, including the f ollowing: -- -- 1. U.S. Department of Transportation, Research and Innovative Technology Administration -- 2. U.S. Department of Transportation, Federal Highway Administration -- 3. AECOM -- 4. Applied Inf ormation -- 5. City of Anaheim, CA -- 6. Consensus Systems Technologies -- 7. Caltrans -- 8. Daktronics -- 9. Econolite Control Products, Inc. -- 10. Florida Department of Transportation -- -- -- -- © 2025 AASHTO / ITE / NEMA Do Not Copy Without Written Permission -- -- NTCIP 1201 v4.0.0 -- Page ii -- -- 11. Georgia DOT -- 12. Kapsch -- 13. KLD Engineering -- 14. Michigan DOT -- 15. Minnesota DOT -- 16. Nevada DOT -- 17. Noblis -- 18. Parsons -- 19. Pillar Consulting -- 20. Q-Free -- 21. Siemens ITS -- 22. Signalisation Ver-Mac, Inc. -- 23. TransCore -- 24. Transport Canada -- 25. Trevilon -- 26. Washington State DOT -- 27. WSP -- -- -- -- -- Do Not Copy Without Written Permission © 2025 AASHTO / ITE / NEMA NTCIP1201-GlobalReport DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-IDENTITY, OBJECT-TYPE, Integer32, Unsigned32, Opaque, zeroDotZero FROM SNMPv2-SMI -- RFC 2578 VariablePointer FROM SNMPv2-TC -- RFC 2579 global FROM NTCIP1201-Global; globalReport MODULE-IDENTITY LAST-UPDATED "20230701145436Z" ORGANIZATION "NTCIP BSP2 WG" CONTACT-INFO "name: NTCIP Coordinator email: ntcip@nema.org postal: National Electrical Manufacturers Association 1300 North 17th Street, Suite 1752 Rosslyn, Virginia 22209-3801" DESCRIPTION " This MIB defines the SMIv2 representation of the NTCIP1103v0352-globalReport MIB, which was defined in NTCIP 1103. This MIB defines objects related to managing event information for the Purpose of logging data within the device. This MIB was deprecated in NTCIP 1201 v04 due to security issues in the structure of the MIB. The objects have been replaced by objects in ISO 26048-1. *** All objects in this MIB have been deprecated. *** The event class table is presented first to ease the readability of the standard; however, the node numbers assigned to this table reflect the original node numbering used in the original 1996 specification to preserve backwards compatibility with existing systems. 1.3.6.1.4.1.1206.4.2.6.4" REVISION "20230701145436Z" DESCRIPTION "NTCIP 1201 v04 - Upgraded format to SMIv2 and deprecated all objects." REVISION "201612310000Z" DESCRIPTION "NTCIP 1103 v03 - No change." REVISION "200903310000Z" DESCRIPTION "NTCIP 1103 v02 - Separated into its own MIB." REVISION "200409270000Z" DESCRIPTION "NTCIP 1103 v01: Original version." ::= { global 4 } maxEventClasses OBJECT-TYPE SYNTAX Integer32 (1..255) UNITS "classes" MAX-ACCESS read-only STATUS deprecated DESCRIPTION " The object defines the number of rows in the eventClassTable that this device supports. This is a static table. The eventClassTable has been replaced with a dynamic table, which does not require an object indicating the maximum number of rows. 1.3.6.1.4.1.1206.4.2.6.4.5" ::= { globalReport 5 } eventClassTable OBJECT-TYPE SYNTAX SEQUENCE OF EventClassEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "This table is used to configure event logging limits and log table maintenance. static ISO26048-1-Log.fdLogManagerTable (ISO 26048-1) 1.3.6.1.4.1.1206.4.2.6.4.6" ::= { globalReport 6 } eventClassEntry OBJECT-TYPE SYNTAX EventClassEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "This defines a row in the Event Class Table ISO26048-1-Log.fdLogManagerEntry (ISO 26048-1) The replacement table adds an index (fdLogManagerOwner) to allow administrators to limit access rights to groups of rows within the table and to allow users to define new rows without worrying if they are overwriting rows managed by other users. The replacement table also adds the following columns: a size limit (in octets) in addition to a limit on the number of entries, a separation of the time into a date and time to parallel the new way to represent time, parameters to configure the type of memory to use to store the log and the log configuration, a counter of the number of events bumped, and a row status. It is missing the number of rows currently in the log. 1.3.6.1.4.1.1206.4.2.6.4.6.1" INDEX { eventClassNumber } ::= { eventClassTable 1 } EventClassEntry ::= SEQUENCE { eventClassNumber Integer32, eventClassLimit Integer32, eventClassClearTime Unsigned32, eventClassDescription OCTET STRING, eventClassNumRowsInLog Integer32, eventClassNumEvents Integer32} eventClassNumber OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This is a class value that is to be configured. ISO26048-1-Log.fdLogManagerName (ISO 26048-1) The replacement object is a secondary index that uses an SnmpAdminString syntax; the primary index is ISO26048-1- Log.fdLogManagerOwner which also uses an SnmpAdminSyntax. 1.3.6.1.4.1.1206.4.2.6.4.6.1.1" ::= { eventClassEntry 1 } eventClassLimit OBJECT-TYPE SYNTAX Integer32 (0..255) UNITS "events" MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This object specifies the maximum number of events of the associated class to store in the log. Once the limit is reached, the oldest entry of the matching class will be overwritten by any new entry of the same class. If the value of this object is set to a number smaller than the current number of rows within this class in the eventLogTable, then the oldest entries shall be lost/deleted. The sum of all event class limits shall not exceed the maxEventLogSize object; if a SET operation to this object causes the sum of eventClassLimit objects to exceed maxEventLogSize, then the agent shall respond with a genErr. The event cannot be logged if the eventClass has an eventClassLimit of zero (0). Event ISO26048-1-Log.fdLogManagerSizeLimit & LOG- MIB.fdLogManagerEntryLimit (ISO 26048-1) The replacement objects allow limits to be placed on the number of entries or the total size. The replacement object for the number of entries has a syntax of Unsigned32. 1.3.6.1.4.1.1206.4.2.6.4.6.1.2" ::= { eventClassEntry 2 } eventClassClearTime OBJECT-TYPE SYNTAX Unsigned32 UNITS "seconds" MAX-ACCESS read-write STATUS deprecated DESCRIPTION " This object is used to clear multiple event log entries from the eventLogTable. All events of this class that have an eventLogTime equal to or less than this object shall be cleared from the eventLogTable. If this object has a value greater than the current value of globalTime, it shall prevent the logging of any events of this class. ISO26048-1-Log.fdLogManagerClearDate & LOG- MIB.fdLogManagerClearTime (ISO 26048-1) This SMIv2 representation of the original SMIv1 object uses an Unsigned32 syntax rather than the original Counter syntax because the definition of the object does not meet the semantics defined for a Counter object. As a result, this object will have a different value in the 'type' field in the BER encoding when transmitted using SNMPv3 (and using SMIv2) than when transmitted using SNMPv1 (and using the SMIv1 definition). The superseding objects use the extended time format that includes a date object (good to the year 65535) and a time object (with millisecond resolution). 1.3.6.1.4.1.1206.4.2.6.4.6.1.3" DEFVAL { 0 } ::= { eventClassEntry 3 } eventClassDescription OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This object specifies a description of the class in ASCII characters. ISO26048-1-Log.fdLogManagerDescription (ISO 26048-1) The replacement object specifies an SnmpAdminString Syntax, which allows management systems to automatically recognize the entry as text in any language. 1.3.6.1.4.1.1206.4.2.6.4.6.1.4" ::= { eventClassEntry 4 } eventClassNumRowsInLog OBJECT-TYPE SYNTAX Integer32 (0..255) UNITS "events" MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The number of rows for this class that currently exist in the eventLogTable. The replacement table does not include a parallel object for this object. 1.3.6.1.4.1.1206.4.2.6.4.6.1.5" ::= { eventClassEntry 5 } eventClassNumEvents OBJECT-TYPE SYNTAX Integer32 (0..65535) UNITS "events" MAX-ACCESS read-only STATUS deprecated DESCRIPTION " This object is a counter that gets incremented every time an event occurs for this class; it shall initialize to zero at power up. The value shall roll over each time it exceeds the maximum of 65535. ISO26048-1-Log.fdLogManagerEventsLogged (ISO 26048-1) The replacement object has a syntax of Counter32. 1.3.6.1.4.1.1206.4.2.6.4.6.1.6" ::= { eventClassEntry 6 } maxEventLogConfigs OBJECT-TYPE SYNTAX Integer32 (1..65535) UNITS "event types" MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The number of rows that exist in the static eventLogConfig table for this device. The eventLogConfigTable has been replaced with a dynamic table, which does not require an object indicating the maximum number of rows. 1.3.6.1.4.1.1206.4.2.6.4.1" ::= { globalReport 1 } eventLogConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF EventLogConfigEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "A table containing Event Log Configuration information. The number of rows in this table is equal to the maxEventLogConfigs object. This table defines the parameters that the device will monitor to create an event.
static ISO26048-1-Log.fdLogFactoryTable (ISO 26048-1) & ISO26048- 1-CondTrigger.fdCondTriggerTable (ISO 26048-1) 1.3.6.1.4.1.1206.4.2.6.4.2" ::= { globalReport 2 } eventLogConfigEntry OBJECT-TYPE SYNTAX EventLogConfigEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "This object defines an entry in the event log configuration table. ISO26048-1-Log.fdLogFactoryEntry (ISO 26048-1) & ISO26048- 1-CondTrigger.fdCondTriggerEntry (ISO 26048-1) The replacement tables have dual indicies consisting of an owner and a name. The trigger table manages the definition of the trigger with the following changes: - A textual description is added - Samples (compare value) can be either the current value (as with this node, or a delta (i.e., how fast a value is changing) - The concept of Opaque is not supported in SNMPv3, so the replacement table includes a 'ValueOctet' object that is used with the bitwise operator - A wildcard column that allows defining the same condition on multiple comparison OIDs (e.g., all rows of a table) - Columns to define the target and context of the comparison object; in other words, the comparison can be performed by a proxy agent or can reference another device to get the object value to compare against - A frequency object that allows the configuration to control how frequently a comparison is made - A truthDuration object that allows the configuration to require the evaluation to be true for some length of time prior to firing the trigger. - Startup objects that define whether the triggers startup in a fired or unfired state (for hysteresis, there are two startups) - A pointer to the action table that identifies the action(s) to be performed. - An error message object that allows a device to report configuration errors. - Counters for the number of times the trigger has fired, had Evaluation errors, and activation errors. - An indication of the type of storage to use - A RowStatus object. The log factory table manages the definition of the information to be recorded with the following changes: - An object context, which allows a proxy/hrbrid agent to capture information from another context - A StorageType object - A RowStatus object 1.3.6.1.4.1.1206.4.2.6.4.2.1" INDEX { eventConfigID } ::= { eventLogConfigTable 1 } EventLogConfigEntry ::= SEQUENCE { eventConfigID Integer32, eventConfigClass Integer32, eventConfigMode INTEGER, eventConfigCompareValue Integer32, eventConfigCompareValue2 Integer32, eventConfigCompareOID VariablePointer, eventConfigLogOID VariablePointer, eventConfigAction INTEGER, eventConfigStatus INTEGER} eventConfigID OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-only STATUS deprecated DESCRIPTION " This object contains the row number which is used to identify the event associated with this row in the eventLogConfigTable. The number of event IDs shall not exceed the value indicated in the maxEventLogConfigs object. ISO26048-1-Log.fdLogFactory 1.3.6.1.4.1.1206.4.2.6.4.2.1.1" ::= { eventLogConfigEntry 1 } eventConfigClass OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This object contains the class value to assign to the event associated with this row in the event configuration table. This value is used in the event log table to organize various events defined in this table into logical groupings. This value shall not exceed the maxEventClasses object value. ISO26048-1-Log.fdLogEventFactoryLogName (ISO 26048-1) The event cannot be logged if the EventClass has an eventClassLimit of zero (0). The replacement object specifies an SnmpAdminString 1.3.6.1.4.1.1206.4.2.6.4.2.1.2" DEFVAL { 1 } ::= { eventLogConfigEntry 2 } eventConfigMode OBJECT-TYPE SYNTAX INTEGER { other (1), onChange (2), greaterThanValue (3), smallerThanValue (4), hysteresisBound (5), periodic (6), andedWithValue (7) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This object specifies the mode of operation for this event. The modes are defined as follows: Value Description other the event mode of operation is not described in this standard, refer to the device manual. onChange create a log entry when the object value referenced by eventConfigCompareOID changes. The values of eventConfigCompareValue and eventConfigCompareValue2 are ignored in this mode. greaterThanValue create a log entry when the object value referenced by eventConfigCompareOID becomes greater than the value of eventConfigCompareValue for the time (tenth seconds) defined by eventConfigCompareValue2 (zero means immediate logging). smallerThanValue create a log entry when the object value referenced by eventConfigCompareOID becomes less than the value of eventConfigCompareValue for the time (tenth seconds) defined by eventConfigCompareValue2 (zero means immediate logging). hysteresisBound create a log entry when the object value referenced by eventConfigCompareOID becomes less than or greater than the bound values. The lowerbound value is the lower value of eventConfigCompareValue and eventConfigCompareValue2; the upperbound value is the higher value of the two values. When the object value becomes greater than the upper bound value, subsequent logging of upperbound conditions shall not occur until the object value becomes less than the lower bound value. When the object value becomes less than the lower bound value, subsequent logging of lowerbound conditions shall not occur until the object value becomes greater than the upper bound value. Periodic create a log entry every x seconds, where x is defined by the value stored in eventConfigCompareValue. The values stored in eventConfigCompareValue2 and eventConfigCompareOID are ignored in this mode. andedWithValue create a log entry when the object value referenced by eventConfigCompareOID ANDED with the value of eventConfigCompareValue is NOT equal to zero for the time (tenth seconds) defined by eventConfigCompareValue2 (zero means immediate logging). This allows monitoring of a specific bit; the condition becomes true anytime that any one of the selected bits become true. ISO26048-1-CondTrigger.fdCondTriggerMode (ISO 26048-1) The replacement object adds the following modes: - equal - not equal - on creation (i.e., creation of a new row in a table) - on deletion - separate modes for octet string and integer bitwise operations 1.3.6.1.4.1.1206.4.2.6.4.2.1.3" DEFVAL { onChange } ::= { eventLogConfigEntry 3 } eventConfigCompareValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This object contains the comparison value to use with eventConfigMode values (greaterThanValue, smallerThanValue, hysteresisBound ). No value within this object is necessary when the eventConfigMode-object has the value onChange (2). ISO26048-1-CondTrigger.fdCondTriggerValue & fdCondTriggerValueOctet (ISO 26048-1) The interger-based replacement object conforms to SNMPv3 rules and does not allow the specification of a 64-bit value and requires integers to be defined as either signed or unsigned. eventConfigCompareValue is perhaps ambiguous about this, although SNMPv1 conventions dictate the same functionality. The result is that the current design does not allow for comparing large unsigned integer values. 1.3.6.1.4.1.1206.4.2.6.4.2.1.4" DEFVAL { 0 } ::= { eventLogConfigEntry 4 } eventConfigCompareValue2 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS deprecated DESCRIPTION "If the eventConfigMode is set to hysteresisBound, this object specifies the second comparison value for the hysteresis. If the eventConfigMode is set to greaterThanValue, smallerThanValue, or andedWithValue, this object specifies the time (in tenths of seconds, +1 tenth / -0 tenths) for which the samples used for comparison shall be true prior to the event condition becoming true. If the eventConfigMode is set to onChange or periodic, the value of this object shall be ignored. The amount of time the condition shall be true is measured in tenths of a second. The accuracy of this timer is limited to +1 tenth of a second and:0 tenths of a second. If the event is true for at least the time shown in this parameter +1 tenth of a second, the condition shall trigger a log entry. It is recognized that some designs only sample the condition periodically, in which case the condition shall be true for at least the time indicated by this object before the event becomes true and the event shall always become true if the condition is true for a duration equal to the value shown in this object plus 1 tenth of a second. ISO26048-1-CondTrigger.fdCondTriggerValue2 (ISO 26048-1) 1.3.6.1.4.1.1206.4.2.6.4.2.1.5" DEFVAL { 0 } ::= { eventLogConfigEntry 5 } eventConfigCompareOID OBJECT-TYPE SYNTAX VariablePointer MAX-ACCESS read-write STATUS deprecated DESCRIPTION " This object contains the object identifier which references the value against which the comparison is made. If the eventConfigMode is set to periodic, the value of this object shall be ignored. If the eventConfigMode is set to greaterThanValue, smallerThanValue or hysteresisBound, this object shall reference an object whose SYNTAX resolves to a ranged or unranged INTEGER. As with all other objects that are sub-ranged by a given implementation, an agent should return a badValue error if it receives a set command indicating a OID which is not supported by the implementation or which is not zeroDotZero. ISO26048-1-CondTrigger.fdCondTriggerObject (ISO 26048-1) 1.3.6.1.4.1.1206.4.2.6.4.2.1.6" DEFVAL { zeroDotZero } ::= { eventLogConfigEntry 6 } eventConfigLogOID OBJECT-TYPE SYNTAX VariablePointer MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This object contains the object identifier which indicates what value to log when a condition or event occurs (e.g., log the phase display when the watchdog alarm status changes). As with all other objects that are sub-ranged by a given implementation, an agent should return a badValue error if it receives a set command indicating a value which is not supported by the implementation. The valid value range of this object shall not include any values, other than zeroDotZero, that do not correspond to objects that may exist within the agent, although it may be further restricted. The valid value range of this object shall not include objects under the following nodes: Security - { nema transportation devices global security } CHAP - { nema transportation protocols layers chap } ISO26048-1-Log.fdLogEventFactoryObjectID (ISO 26048-1) 1.3.6.1.4.1.1206.4.2.6.4.2.1.7" DEFVAL { zeroDotZero } ::= { eventLogConfigEntry 7 } eventConfigAction OBJECT-TYPE SYNTAX INTEGER { other (1), disabled (2), log (3) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "The value of this object indicates what action shall take place when this event occurs. Other - indicates that the action is other than defined in this standard. This value exists in order to support proprietary event logging mechanisms configured by other means not specified in this standard. If this value is used in a SET request, the agent shall respond with a badValueError. Disabled - no event log entry shall be generated or recorded due to this event. In an agent complying with NTCIP 1103 v03 or later, this event shall not be used to trigger NTCIP traps, nor to construct NTCIP trap messages. Log - an event log entry shall be generated when this event occurs. In an agent complying with NTCIP 1103 v03 and later, this may trigger an NTCIP trap (see the eventConfigID index element of trapTable). If eventConfigClass refers to an eventClassTable row having eventClassLimit = 0, the log entry's eventLogValue shall be used to construct any necessary trap messages implied by the associated trapTable rows, but the log entry shall then be discarded and not added to the eventLogTable. If the eventClassLimit is greater than zero, the log entry shall be added to the eventLogTable, subject to the constraints imposed by the associated eventConfigClass. ISO26048-1-CondTrigger.fdCondTriggerActionOwner, fdCondTriggerAction, fdCondTriggerActionOwner2, & fdCondTriggerAction2 (ISO 26048-1) The replacement object points to a table that can point to multiple actions. For example, a single trigger can result in both a log entry and a notification. 1.3.6.1.4.1.1206.4.2.6.4.2.1.8" DEFVAL { disabled } ::= { eventLogConfigEntry 8 } eventConfigStatus OBJECT-TYPE SYNTAX INTEGER { other (1), disabled (2), log (3), error (4) } MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The value of this object indicates the current status of the configured event. Upon setting any object in this row of the eventLogConfigTable, the agent will determine if the setting is valid and will set this object to one of the following states: other indicates that the action is successfully set to a mode other than that defined in this standard disabled indicates that the action is set to disabled log indicates that the action is successfully set to the log state after passing consistency checks. error indicates that the requested action could not be implemented due to a consistency check ISO26048-1-CondTrigger.fdCondTriggerRowStatus (ISO 26048-1) & ISO26048-1-Log.fdLogEventFacoryRowStatus (ISO 26048-1) 1.3.6.1.4.1.1206.4.2.6.4.2.1.9" ::= { eventLogConfigEntry 9 } maxEventLogSize OBJECT-TYPE SYNTAX Integer32 (1..65535) UNITS "events" MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The maximum, fixed number of rows that can be utilized within the eventLogTable. ISO26048-1-Log.fdLogsGlobalEntryLimit and fdLogsGlobalSizeLimit (ISO 26048-1) The replacement objects are for all managers. 1.3.6.1.4.1.1206.4.2.6.4.3" ::= { globalReport 3 } eventLogTable OBJECT-TYPE SYNTAX SEQUENCE OF EventLogEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "A table containing Event History data collected. A request for an object from a row that has not been instantiated or has been cleared shall return a noSuchName error.
dynamic ISO26048-1-Log.fdLogTable (ISO 26048-1) 1.3.6.1.4.1.1206.4.2.6.4.4" ::= { globalReport 4 } eventLogEntry OBJECT-TYPE SYNTAX EventLogEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "This object defines an entry in the event log Table. ISO26048-1-Log.fdLogEntry (ISO 26048-1) EventLogTable was modified in NTCIP 1103 v03 to add an entry eventLogTimeMilliseconds Integer, which did not exist in NTCIP 1103 v02. The replacement table precedes the class/manager and number indicies With an owner so that access to information in the table can be controlled with proper configuration of the SNMP agent. The replacement table also records both the date and time of the event and the date and time that the event was placed into the table (i.e., so that if there is latency, a command to clear the table does not inadvertently delete rows that had occurred but had not been entered into the table. 1.3.6.1.4.1.1206.4.2.6.4.4.1" INDEX { eventLogClass, eventLogNumber } ::= { eventLogTable 1 } EventLogEntry ::= SEQUENCE { eventLogClass Integer32, eventLogNumber Integer32, eventLogID Integer32, eventLogTime Unsigned32, eventLogValue Opaque, eventLogTimeMilliseconds Integer32} eventLogClass OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This object contains the class of the associated event as defined in the eventLogConfig Table. ISO26048-1-Log.fdLogManagerOwner & fdLogManagerName (ISO 26048-1) The replacement objects are SnmpAdminStrings 1.3.6.1.4.1.1206.4.2.6.4.4.1.1" ::= { eventLogEntry 1 } eventLogNumber OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The event number within this class for this event. Event numbers shall be assigned starting at 1 and shall increase to the value specified by the associated eventClassLimit for the class associated with the rows. Events shall maintain a chronological ordering in the table with the oldest event of a class occupying the row with eventNumber = 1, and subsequent events filling subsequent rows. This ordering shall be maintained for those rows still remaining when events are cleared. ISO26048-1-Log.fdLogIndex (ISO 26048-1) The replacement object is an Unsigned32 1.3.6.1.4.1.1206.4.2.6.4.4.1.2" ::= { eventLogEntry 2 } eventLogID OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This object contains the event configuration ID (from the eventLogConfigTable) that caused this table entry. It indicates the row in the eventLogConfig table responsible for this event entry. ISO26048-1-Log.fdLogFactoryName (ISO 26048-1) The replacement object is an SnmpAdminString 1.3.6.1.4.1.1206.4.2.6.4.4.1.3" ::= { eventLogEntry 3 } eventLogTime OBJECT-TYPE SYNTAX Unsigned32 UNITS "seconds" MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The time that the event was detected. If the device supports the globalTime object, the value shall reflect the value of globalTime when the event occurred, otherwise this shall be the time in seconds since the device powered up. The event shall be detected and timestamped within one second from the event becoming true. The event shall be logged in the table within five seconds of the event being detected. These timing resolutions may be modified by a device profile. ISO26048-1-Log.fdLogEventDate, fdLogEventTime, fdLogDate, fdLogTime (ISO 26048-1) This SMIv2 representation of the original SMIv1 object uses an Unsigned32 syntax rather than the original Counter syntax because the definition of the object does not meet the semantics defined for a Counter object. As a result, this object will have a different value in the 'type' field in the BER encoding when transmitted using SNMPv3 (and using SMIv2) than when transmitted using SNMPv1 (and using the SMIv1 definition). The superseding objects adopt the new time format. They also distinguish between event time and log time. 1.3.6.1.4.1.1206.4.2.6.4.4.1.4" ::= { eventLogEntry 4 } eventLogValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The value of this object is set to the BER encoding of the value referenced by the eventConfigLogOID of the associated eventLogID when the event was logged. Its length is variable. The value shall not contain any padding characters either before or after the values. NOTE: Opaque objects are doubly wrapped. For SNMP operations, which use BER, this would be {type, length, {type, length, value}}. For example, a zero-length octet string, would be encoded in BER as 0x44 02 04 00. For STMP or SFMP operations, which use OER, this would be { length, {type, length, value}}. For example, the same example would be encoded in OER as 0x02 04 00. ISO26048-1-Log.fdLogValue (ISO 26048-1) The replacement object uses an ITSOerString (i.e., the value is in OER and sent over SNMP with a BER wrapper as opposed to the Opaque which created a double BER wrapper). This means that the manager who requests the value must know the syntax that was encoded. 1.3.6.1.4.1.1206.4.2.6.4.4.1.5" ::= { eventLogEntry 5 } eventLogTimeMilliseconds OBJECT-TYPE SYNTAX Integer32 (0..999) UNITS "milliseconds" MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The number of milliseconds after the beginning of the second indicated by the value of eventLogTime at which the event was detected. Devices that do not support sub-second event time resolution shall always set this object to zero. When implementing eventLogTimeMilliseconds, devices require a time source with millisecond-level resolution, such as GPS or TIA (International Atomic Time). ISO26048-1-Log.fdLogEventTime, fdLogTime This data content is covered by the new time format used by ISO26048-1-Log.fdLogEventTime & fdLogTime (ISO 26048-1) 1.3.6.1.4.1.1206.4.2.6.4.4.1.6" ::= { eventLogEntry 6 } numEvents OBJECT-TYPE SYNTAX Integer32 (0..65535) UNITS "events" MAX-ACCESS read-only STATUS deprecated DESCRIPTION " This object is a counter that gets incremented every time an event occurs and shall initialize to zero at power up. The value shall roll over each time it exceeds the maximum of 65535. ISO26048-1-Log.fdLogsTotalLogged (ISO 26048-1) The replacement object uses a syntax of Counter32, which does not require a zero-base. 1.3.6.1.4.1.1206.4.2.6.4.7" ::= { globalReport 7 } eventTimeLatency OBJECT-TYPE SYNTAX Integer32 (0..1000) UNITS "milliseconds" MAX-ACCESS read-only STATUS deprecated DESCRIPTION " This object indicates the maximum amount of time, in milliseconds, that may elapse between an event's occurrence and the time reported for that event entry in the eventLogTable. This is a global, constant value that reports the capability of the device with respect to event-reporting latency. It should account for all sources of latency, including both hardware and firmware delays. If eventTimeLatency has a value of L, this means that any event in the eventLogTable may actually have occurred up to L milliseconds prior to the time reported by the eventLogTime and eventLogTimeMilliseconds values associated with the event. A value of 0 indicates that the device reports accurate event times with millisecond resolution. A value of 1000 indicates that the device cannot accurately report sub-second event times. ISO26048-1-Log.fdLogsRecordingLatency (ISO 26048-1) The replacement object places limits on the time between retrieving the value to log and the logging rather than what is described here. 1.3.6.1.4.1.1206.4.2.6.4.8" ::= { globalReport 8 } END