-- OIDref derived MIB transcription. Original PDF: https://www.ntcip.org/file/2018/11/NTCIP1201v0110b.pdf -- Publisher front matter and notices follow as comments. -- A Joint Standard of AASHTO, ITE, and NEMA -- -- -- -- -- NTCIP 1201:1996 v01.10 -- -- -- -- National Transportation -- Communications for ITS Protocol -- -- Global Object Definitions -- -- December 2001 -- -- Includes Jointly Approved NTCIP 1201 Amendment 1 v07 -- -- The Adobe® PDF copy of this NTCIP standard is available for a limited time through support from -- the U.S. DOT / Federal Highway Administration, whose assistance is gratefully acknowledged. -- -- -- -- -- Published by -- -- American Association of State Highway and Transportation Officials (AASHTO) -- 444 North Capitol Street, N.W., Suite 249 -- Washington, D.C. 20001 -- -- Institute of Transportation Engineers (ITE) -- 1099 14th Street, N.W., Suite 300 West -- Washington, D.C. 20005-3438 -- -- National Electrical Manufacturers Association (NEMA) -- 1300 North 17th Street, Suite 1847 -- Rosslyn, Virginia 22209-3801 -- -- -- --  2001 AASHTO / ITE / NEMA. All rights reserved. -- --  2001 by the National Electrical Manufacturers Association (NEMA). All intellectual property rights, including, but not limited to, the -- rights of reproduction in whole or in part in any form, translation into other languages and display are reserved by the copyright -- owner under the laws of the United States of America, the Universal Copyright Convention, the Berne Convention, and the -- International and Pan American Copyright Conventions. Except for the MIB or the PRL, do not copy without written permission of -- NEMA. -- -- NTCIP 1201:1996 v01.10 -- Page i -- -- -- -- ACKNOWLEDGEMENTS -- -- -- This publication was prepared by the NTCIP Global Object Working Group, which is a subdivision of the -- Joint Committee on the NTCIP. The Joint Committee is organized under a Memorandum of -- Understanding among the American Association of State Highway and Transportation Officials -- (AASHTO), the Institute of Transportation Engineers (ITE), and the National Electrical Manufacturers -- Association (NEMA). The Joint Committee on the NTCIP consists of six representatives from each of the -- standards organizations, and provides guidance for NTCIP development. -- -- At the time that this document was prepared, the following individuals were active members of the NTCIP -- Global Object Working Group: -- • Bob De Roche -- • Curtis Herrick -- • Bud Kent -- • Gary Meredith -- • Nu Rosenbohm -- • Ken Vaughn (Chair) -- -- -- In addition to the many volunteer efforts, recognition is also given to those organizations who supported -- the efforts of the working groups by providing comments and funding for the standard, including: -- • Eagle Traffic Control Systems -- • Econolite Control Products, Inc. -- • Gardner Systems -- • Iteris, Inc. -- • PB Farradyne Inc -- • Peek Traffic Systems, Inc. -- -- -- -- -- © 2001 NEMA Do Not Copy Without Written Permission -- -- NTCIP 1201:1996 v01.10 -- Page ii -- -- -- -- FOREWORD -- -- -- This document uses only metric units. -- -- The purpose of this publication is to identify and define the common object definitions that may be -- supported by devices that are NTCIP-compliant. This document is an NTCIP Data Dictionary Standard. -- Data Dictionary Standards provide formal definitions of data elements for use within NTCIP systems. -- -- For more information about NTCIP standards, visit the NTCIP Web Site at http://www.ntcip.org. For a -- hardcopy summary of NTCIP information, contact the NTCIP Coordinator at the address below. -- -- In preparation of this NTCIP document, input of users and other interested parties was sought and -- evaluated. Inquires, comments, and proposed or recommended revisions should be submitted to: -- -- NTCIP Coordinator -- National Electrical Manufacturers Association -- 1300 North 17th Street, Suite 1847 -- Rosslyn, VA 22209-3801 -- fax: (703) 841-3331 -- e-mail: ntcip@nema.org -- -- Approvals -- -- This document was separately balloted and approved by AASHTO, ITE, and NEMA after -- recommendation by the Joint Committee on the NTCIP. Each organization has approved this standard -- as the following standard type, as of the date: -- -- AASHTO – Standard Specification; 1997 -- ITE – Software Standard; December 1997 -- NEMA – Standard; October 1996 -- -- History -- -- From 1996 to 1999, this document was referenced as NEMA TS 3.4. However, to provide an organized -- numbering scheme for the NTCIP documents, this document is now referenced as NTCIP 1201. The -- technical specifications of NTCIP 1201 are identical to the former reference, except as noted in the -- development history below: -- -- NEMA TS 3.4-1996 v96.01.7, April 7, 1997. October 1996 – Version 1.5 approved by NEMA. -- April 1997 – Version 1.7 published by NEMA with editorial corrections. October 1996 – Accepted -- as a Recommended Standard by the Joint Committee on the NTCIP. Approved by AASHTO in -- 1997 and approved by ITE in December 1997. -- -- NEMA TS 3.4 Amendment 1 v98.01.07. October 1998 – Version 98.01.05 accepted as a -- Recommended Amendment by the Joint Committee on the NTCIP, and edited v01.07 referred for -- balloting and approval by NTCIP Standards Bulletin B0032 in May 1999. Approved by AASHTO -- in October 1999, approved by ITE in January 2001, and approved by NEMA in December 1999. -- -- NTCIP 1201:1996 [assigned version 01.08]. August 1999 – Assigned NTCIP 1201 document -- number in NTCIP Standards Bulletin B0038. August 2000 – Joint NTCIP Standards Publication -- cover used over TS 3.4 contents. -- -- -- -- -- Do Not Copy Without Written Permission © 2001 NEMA -- -- NTCIP 1201:1996 v01.10 -- Page iii -- -- -- -- NTCIP 1201:1996 v01.10, December 2001. January 2002 – Formatted for printing: incorporated -- Amendment 1 v07 into text; updated title page date and version number; modified and -- reorganized front matter to conform to NTCIP 8002. Most references to TS 3 standard -- designations were changed to equivalent NTCIP standard numbers. -- -- -- -- -- © 2001 NEMA Do Not Copy Without Written Permission -- -- NTCIP 1201:1996 v01.10 -- Page iv -- -- -- -- INTRODUCTION -- -- -- This publication provides definitions of data elements for use with various transportation devices. The -- data is defined using the Simple Network Management Protocol (SNMP) object-type format as defined in -- RFC 1212 and the defined NTCIP format defined in NTCIP 8004. This data would typically be -- exchanged using one of the NTCIP 1103 recognized Application Layers (e.g., SNMP). -- -- This standard defines requirements that are applicable to all NTCIP environments and it also contains -- optional and conditional clauses that are applicable to specific environments for which they are intended. -- -- The following keywords apply to this document: AASHTO, ITE, NEMA, NTCIP, global, data, data -- dictionary, object. -- -- In 1992, the NEMA 3-TS Transportation Management Systems and Associated Control Devices Section -- began the effort to develop the NTCIP. The Transportation Section’s purpose was to respond to user -- needs to include standardized systems communication in the NEMA TS 2 standard, Traffic Controller -- Assemblies. Under the guidance of the Federal Highway Administration’s NTCIP Steering Group, the -- NEMA effort was expanded to include the development of communications standards for all -- transportation field devices that could be used in an Intelligent Transportation Systems (ITS) network. -- -- In September 1996, an agreement was reached among NEMA, ITE, and AASHTO to jointly develop, -- approve, and maintain NTCIP Standards. In late 1998, the Global Object Working Group was tasked with -- the effort to update the Global Object Definitions document. The first meeting of this working group was -- held in January 1999. -- -- The first version of this document was published as NEMA TS 3.4-1996; however, in 1997, both AASHTO -- and ITE adopted the standard. Thus, in order to provide an organized numbering scheme and to reflect -- the joint approval of AASHTO, ITE, and NEMA, the updated document is now numbered NTCIP 1201. -- The reformatted version was developed to reflect lessons learned and to add new features from the -- approved amendment. -- -- -- -- -- Do Not Copy Without Written Permission © 2001 NEMA -- -- NTCIP 1201:1996 v01.10 -- Page v -- -- -- -- If you are not willing to abide by the following notices, return these materials immediately. -- -- Joint AASHTO, ITE, and NEMA -- NTCIP Management Information Base and Data Dictionary -- DISTRIBUTION NOTICE -- -- To the extent and in the limited event these materials are distributed by AASHTO/ITE/NEMA in the form -- of a Management Information Base (“MIB”) or Data Dictionary and ASN.1 Script (“DD”), AASHTO / ITE / -- NEMA extends the following permissions: -- -- (i) you may make and/or distribute unlimited copies (including derivative works) of the MIB, including -- copies for commercial distribution, provided that (a) each copy you make and/or distribute contains this -- Notice and (b) each derivative work of the MIB uses the same module name followed by “-,” followed by -- your Internet Assigned Number Authority (IANA)-assigned enterprise number; -- (ii) use of the MIB is restricted in that the syntax field may be modified only to reflect a more restrictive -- subrange or enumerated values; -- (iii) the description field may be modified but only to the extent that: (a) only those bit values or -- enumerated values that are supported are listed; and (b) the more restrictive subrange is expressed. -- -- These materials are delivered “AS IS” without any warranties as to their use or performance. -- -- AASHTO / ITE / NEMA AND THEIR SUPPLIERS DO NOT WARRANT THE PERFORMANCE OR -- RESULTS YOU MAY OBTAIN BY USING THESE MATERIALS. AASHTO/ITE/NEMA AND THEIR -- SUPPLIERS MAKE NO WARRANTIES, EXPRESS OR IMPLIED, AS TO NONINFRINGEMENT OF -- THIRD PARTY RIGHTS, MERCHANTABILITY, OR FITNESS FOR ANY PARTICULAR PURPOSE. IN -- NO EVENT WILL AASHTO, ITE, OR NEMA OR THEIR SUPPLIERS BE LIABLE TO YOU OR ANY -- THIRD PARTY FOR ANY CLAIM OR FOR ANY CONSEQUENTIAL, INCIDENTAL, OR SPECIAL -- DAMAGES, INCLUDING ANY LOST PROFITS OR LOST SAVINGS, ARISING FROM YOUR -- REPRODUCTION OR USE OF THESE MATERIALS, EVEN IF AN AASHTO, ITE, OR NEMA -- REPRESENTATIVE HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. Some states -- or jurisdictions do not allow the exclusion or limitation of incidental, consequential, or special damages, or -- the exclusion of implied warranties, so the above limitations may not apply to you. -- -- Use of these materials does not constitute an endorsement or affiliation by or between AASHTO, ITE, or -- NEMA and you, your company, or your products and services. -- -- Disclaimer -- -- The information in this publication was considered technically sound by the consensus of persons -- engaged in the development and approval of the document at the time it was developed. Consensus -- does not necessarily mean that there is unanimous agreement among every person participating in the -- development of this document. -- -- AASHTO, ITE, and NEMA standards and guideline publications, of which the document contained herein -- is one, are developed through a voluntary consensus standards development process. This process -- brings together volunteers and/or seeks out the views of persons who have an interest in the topic -- covered by this publication. While AASHTO, ITE, and NEMA administer the process and establish rules -- to promote fairness in the development of consensus, they do not write the document and they do not -- independently test, evaluate, or verify the accuracy or completeness of any information or the soundness -- of any judgments contained in their standards and guideline publications. -- -- AASHTO, ITE, and NEMA disclaim liability for any personal injury, property, or other damages of any -- nature whatsoever, whether special, indirect, consequential, or compensatory, directly or indirectly -- resulting from the publication, use of, application, or reliance on this document. AASHTO, ITE, and -- -- -- -- © 2001 NEMA Do Not Copy Without Written Permission -- -- NTCIP 1201:1996 v01.10 -- Page vi -- -- -- -- NEMA disclaim and make no guaranty or warranty, express or implied, as to the accuracy or -- completeness of any information published herein, and disclaims and makes no warranty that the -- information in this document will fulfill any of your particular purposes or needs. AASHTO, ITE, and -- NEMA do not undertake to guarantee the performance of any individual manufacturer or seller’s products -- or services by virtue of this standard or guide. -- -- In publishing and making this document available, AASHTO, ITE, and NEMA are not undertaking to -- render professional or other services for or on behalf of any person or entity, nor are AASHTO, ITE, and -- NEMA undertaking to perform any duty owed by any person or entity to someone else. Anyone using this -- document should rely on his or her own independent judgment or, as appropriate, seek the advice of a -- competent professional in determining the exercise of reasonable care in any given circumstances. -- Information and other standards on the topic covered by this publication may be available from other -- sources, which the user may wish to consult for additional views or information not covered by this -- publication. -- -- AASHTO, ITE, and NEMA have no power, nor do they undertake to police or enforce compliance with the -- contents of this document. AASHTO, ITE, and NEMA do not certify, test, or inspect products, designs, or -- installations for safety or health purposes. Any certification or other statement of compliance with any -- health or safety–related information in this document shall not be attributable to AASHTO, ITE, or NEMA -- and is solely the responsibility of the certifier or maker of the statement. -- -- -- NTCIP is a trademark of AASHTO / ITE / NEMA -- -- -- -- -- Do Not Copy Without Written Permission © 2001 NEMA GLOBAL DEFINITIONS ::= BEGIN --For the purpose of this section, the following OBJECT IDENTIFIERS are used: IMPORTS OBJECT-TYPE FROM RFC-1212 transportation FROM NEMA_SMI devices, protocols, profiles FROM TMIB Opaque, Counter FROM RFC1155-SMI global OBJECT IDENTIFIER ::= { devices 6 } globalConfiguration OBJECT IDENTIFIER ::= { global 1 } --This node is an identifier used to group all objects for support of configuration functions -- that are common to most device types. © 2001 NEMA Copy per MIB Distribution Notice globalSetIDParameter OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS optional DESCRIPTION "Specifies a relatively unique ID for all user-changeable parameters of the particular device-type currently implemented in the device. Often this ID is calculated using a CRC algorithm." ::= { globalConfiguration 1 } globalMaxModules OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "The number of rows that are listed in the Global Module Table." ::= { globalConfiguration 2 } globalModuleTable OBJECT-TYPE SYNTAX SEQUENCE OF ModuleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table containing information regarding manufacturer of software and hardware and the associated module models and version numbers as well as an indicator if the module is hardware or software related. The number of rows in this table shall equal the value of the globalMaxModule object." ::= { globalConfiguration 3 } moduleEntry OBJECT-TYPE SYNTAX ModuleTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This object defines an entry in the module table" INDEX { moduleNumber } ::= { globalModuleTable 1 } ModuleTableEntry ::= SEQUENCE { moduleNumber INTEGER, moduleDeviceNode OBJECT IDENTIFIER, moduleMake OCTET STRING, moduleModel OCTET STRING, moduleVersion OCTET STRING, moduleType INTEGER } moduleNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "This object contains the row number (1..255) within this table for the associated module." ::= { moduleEntry 1 } moduleDeviceNode OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "This object contains the device node number of the device-type." ::= { moduleEntry 2 } moduleMake OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the manufacturer of the associated module. A null-string shall be transmitted if this object has no entry." ::= { moduleEntry 3 } moduleModel OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the model number (hardware) or firmware reference (software) of the associated module. A null-string shall be transmitted if this object has no entry." ::= { moduleEntry 4 } moduleVersion OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the version of the associated module. A null-string shall be transmitted if this object has no entry." ::= { moduleEntry 5 } moduleType OBJECT-TYPE SYNTAX INTEGER { other (1), hardware (2), software (3) } ACCESS read-only STATUS mandatory DESCRIPTION © 2001 NEMA Copy per MIB Distribution Notice "This object specifies if the associated module is a hardware or software module." ::= { moduleEntry 6 } globalDBManagement OBJECT IDENTIFIER ::= { global 2 } -- This node is an identifier used to group all objects for support of database -- functions that are common to most device types. dbCreateTransaction OBJECT-TYPE SYNTAX INTEGER { normal (1), transaction (2), verify (3), done (6) } ACCESS read-write STATUS mandatory DESCRIPTION: "This object provides transaction control for device configuration. The transaction mode changes the behavior of the agent to force buffering of database objects until all related database objects have been modified. In the normal mode, SET operations to database objects may be stored in a device’s database immediately with no regard to whether other changes will be made. In the transaction mode, SET operations to database objects are buffered until a verify state performs a consistency check. When the consistency check completes, the device automatically transitions to the done state where a normal or transaction command can be issued. A database object is a user provided piece of setup information that is necessary for the proper operation of a device. It is static in nature in that the agent would never change it without direction from the management station. For example, a parameter that defines a default mode of operation would be a database object. A parameter that indicates the current state of the device would not be a database object. The states and commands are defined as: NORMAL: SET operations behave as normal SNMP SETs and can have an immediate effect on the value of any database objects used by the device. This is the default state of this object. The only command that may be written to dbCreateTransaction while in this state is TRANSACTION. Any other values written to this object in this state shall result in an error response of ‘badValue’. TRANSACTION: SET operations of database objects are buffered by the agent device for later consistency checks. Standard SYNTAX checking takes place at the time of the SET operation. A transaction may consist of multiple SET operations over multiple frames. The only commands that can be written to dbCreateTransaction while in this state are VERIFY and NORMAL. A VERIFY command will change the state to VERIFY. If a NORMAL command is received, all buffered data is discarded and the state is returned to NORMAL. Any other values written to this object when in this state shall result in an error response of ‘badValue’. VERIFY: Specific database objects are checked for consistency. When consistency checks are complete the device will automatically advance to the DONE state. The state of dbCreateTransaction cannot be changed when in the VERIFY state. Any other values written to this object in this state shall result in an error response of ‘badValue’. The consistency check analyzes certain critical objects ‘in context’ and treats them as an interrelated whole rather than separate non-related data items. The consistency check rules are not defined in this standard. They are device and implementation specific. Where applicable, the consistency check rules are defined in application specific object definition standards. A specific implementation may add additional checks beyond those defined in the standards. As a simplified example of a consistency check, consider the following. Two objects are defined to specify the month and the day-of-month of an event. Valid values for day-of-month would normally be 1 to 31, but in the context of month 9 (September), only the values 1 to 30 are correct. DONE: This state is entered automatically once consistency checks have completed in the VERIFY mode. The value of dbVerifyStatus and dbVerifyError indicate whether the consistency check found any errors. Only two valid values can be written to dbCreateTransaction in this state: NORMAL and TRANSACTION. Any other values written to this object in this state shall result in an error response of ‘badValue’. If a NORMAL command is issued and dbVerifyStatus indicates doneWithNoError, the buffered data is transferred to the device memory and the state is returned to NORMAL. If a NORMAL command is issued and dbVerifyStatus indicates something other than doneWithError then the buffered data is discarded and the state is returned to NORMAL. If a TRANSACTION command is issued, regardless of dbVerifyStatus, no action takes place (the buffered data is not changed) and the TRANSACTION state is re-entered. COMMANDED STATE transaction verify normal done normal transaction (1) normal (2) normal (2) normal (2) transaction transaction (2) verify (3) normal (4) transaction (2) CURRENT STATE verify (7) verify (2) verify(2) verify (2) verify (2) done (8) transaction (5) done(2) normal (6) done (2) Operational procedures and error responses: (1) Once a copy of all database objects is placed in a buffer the state is changed to transaction and error response indicates noError. If the operation fails, the state remains the same and error response indicates genErr. (2) No action takes place, the state remains the same, but response indicates badValue. (3) The state is changed to verify, a consistency check is started, and response indicates noError. (4). The buffered copy of all database objects is discarded, the state is changed to normal, and response indicates noError. © 2001 NEMA Copy per MIB Distribution Notice (5) The buffered copy of all database objects is not changed or reloaded, the state is changed to transaction, and response indicates noError. (6) If dbVerifyStatus indicates doneWithNoError, then the copy of all database objects is transferred to memory, the state is changed to normal and response indicates noError. If dbVerifyStatus indicates doneWithError then the buffered data is discarded, the state is changed to NORMAL, and response indicates noError. (7) The state will automatically change to done when the consistency check completes. (8) dbVerifyStatus and dbVerifyError are only valid in this state." ::= { globalDBManagement 1 } dbErrorType OBJECT-TYPE SYNTAXINTEGER { tooBig (1), noSuchName (2), badValue (3), readOnly (4), genError (5), updateError (6), noError (7) } ACCESS read-only STATUS deprecated DESCRIPTION: "This object returns the current error status of the transaction. The value of this object is only valid when the dbCreateTransaction object is in the Done or Error state." ::= { globalDBManagement 2 } dbErrorID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS deprecated DESCRIPTION "This object contains the object identifier of the first object in the transaction buffer that caused an error while dbCreateTransaction object was in the Verifying or Updating state. The value of this object is only valid when the dbCreateTransaction object is in the Error state. It is undefined when the dbCreateTransaction object is in other states." ::= { globalDBManagement 3 } dbTransactionID OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS deprecated DESCRIPTION "This object contains the transaction ID value that is to be contained in all SET operation writes while the dbCreateTransaction object is not in the Normal state. During transaction operations every SET command shall begin with a write to this object with the current value of this object. If a SET operation is performed without writing to this object, or with a value that does not match the current value, then an error response of ‘genError’ shall be returned. This mechanism is used to determine that the same management station that started the transaction is performing the SET operations that are being buffered or modifying the state of dbCreateTransaction." ::= { globalDBManagement 4 } dbMakeID OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS deprecated DESCRIPTION "This object is used to create unique transaction ID’s for management stations to use when starting transactions using the dbCreateTransaction object. This object will be incremented by one every time it is read, so that different values will be returned for each read. Management stations wishing to start a transaction should first read the dbCreateTransaction object to verify that it is in the Normal state. If so then the management shall GET dbMakeID to obtain a transaction ID to use, then SET dbCreateTransaction to startCmd and dbTransactionID to the value just received. If the response to the SET operation is ‘noError’ then the management station has started a transaction. If the response to the SET operation is ‘genError’ then the management station should read the dbCreateTransaction and dbTransactionID objects to ensure that the error was not due to a communications retry. If the dbCreateTransaction is in the Transaction state, and the dbTransactionID is the same value returned by the read of this object, then the management station is the owner of the transaction. If the dbTransactionID does not match the value originally returned by this object, then the management station is not the owner of the transaction and must wait until the dbCreateTransaction object returns to the Normal state before attempting to start the transaction." ::= { globalDBManagement 5 } dbVerifyStatus OBJECT-TYPE SYNTAX INTEGER { notDone (0), doneWithError (1), doneWithNoError (2) } ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the current status of verify (consistency checking) processing. The value of this object is only valid when the dbCreateTransaction object is in the Verify or Done state. If read during any other state, the value of this object is not valid but no error will be indicated." ::= { globalDBManagement 6 } dbVerifyError OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "This object contains a textual description of or a reference to an error that was found by the verify (consistency checking) processing. The value of this object is only valid when the dbCreateTransaction object is in the Done state and the dbVerifyStatus object is in the doneWithError state. If read during any other state, the value of this object is not valid but no error will be indicated." ::= { globalDBManagement 7 } © 2001 NEMA Copy per MIB Distribution Notice globalTimeManagement OBJECT IDENTIFIER ::= { global 3 } -- This node is an identifier used to organize all objects for support of time-related -- functions that are common to most device types. globalTime OBJECT-TYPE SYNTAX Counter ACCESS read-write STATUS mandatory DESCRIPTION: "The current time in seconds since the epoch of 00:00:00 (midnight) January 1, 1970 UTC (a.k.a. Zulu)." ::= { globalTimeManagement 1 } globalDaylightSaving OBJECT-TYPE SYNTAX INTEGER { other (1), disableDST (2), enableUSDST (3) } ACCESS read-write STATUS mandatory DESCRIPTION: "This object specifies if the Daylight Savings Time (DST) is enabled, disabled or some other form of daylight savings time is active. disableDST - DST clock adjustments shall NOT occur. enableUSDST - DST clock adjustments shall occur. In accordance with USA practice, DST shall begin the first Sunday in April and shall end the last Sunday on October. All changes of time occur at 2:00AM." REFERENCE "NEMA TS 2 Clause 3.8.2" ::= { globalTimeManagement 2 } timebase OBJECT IDENTIFIER ::= { globalTimeManagement 3 } -- This node is an identifier used to organize the main objects for event scheduling. -- Device type-specific objects (tables) pointed to are defined within the appropriate MIB. maxTimeBaseScheduleEntries OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object specifies the maximum number of different entries supported by the device as shown by the number of rows in the timeBaseScheduleTable." ::= { timebase 1 } timeBaseScheduleTable OBJECT-TYPE SYNTAX SEQUENCE OF TimeBaseScheduleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing the time base schedule parameters for the device. The number of rows in this table might be equal but is not allowed to exceed the value of the maxTimeBaseScheduleEntries object. The table references the appropriate day plan for the device. The plan is determined by comparing the current month (MONTH), day of week (DOW) and date of month (DOM) to the appropriate fields. The settings for MONTH, DOW and DOM are connected with a logical AND. In order to determine which timebased event to select, determine the event which has the most specific date specified. Select the more specific event based on their MONTH settings; if the same, select the most specific DOM; if that is still the same, select the most specific DOW; if that’s still the same, the first occurrence within the time base event table shall be selected. "More specific" means the least number of bits set within an object. All entries in Time Base Schedule Table are expressed in local time and date." ::= { timebase 2 } timeBaseScheduleEntry OBJECT-TYPE SYNTAX TimeBaseScheduleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Event Parameters for the time based schedule programming of the device." INDEX { timeBaseScheduleNumber } ::= { timeBaseScheduleTable 1 } TimeBaseScheduleEntry ::= SEQUENCE { timeBaseScheduleNumber INTEGER, timeBaseScheduleMonth INTEGER, timeBaseScheduleDay INTEGER, timeBaseScheduleDate INTEGER, timeBaseScheduleDayPlan INTEGER 2.4.3.2.1 Time Base Schedule Number Parameter timeBaseScheduleNumber OBJECT-TYPE SYNTAX INTEGER (1..65535 ) ACCESS read-only STATUS mandatory DESCRIPTION "The time base schedule number for objects in this row. The value of this object shall not exceed the value of the maxTimeBaseScheduleEntries object. The activation of a scheduled entry shall occur whenever allowed by all other objects within this table." ::= { timeBaseScheduleEntry 1 } 2.4.3.2.2 Time Base Schedule Month of Year Parameter timeBaseScheduleMonth OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The Month(s) of the Year that the schedule entry shall be allowed. Each bit represents a specific month. If the bit is set to one (1), then the scheduled entry shall be allowed during the associated month. If the © 2001 NEMA Copy per MIB Distribution Notice bit is zero (0), then the scheduled entry shall not be allowed during the associated month. The bits are defined as: Bit Month of Year 0 Reserved 1 January 2 February 3 March 4 April 5 May 6 June 7 July 8 August 9 September 10 October 11 November 12 December 13 - 15 Reserved" ::= { timeBaseScheduleEntry 2 } 2.4.3.2.3 Time Base Schedule Day of Week Parameter timeBaseScheduleDay OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "The Day(s) of Week that the schedule entry shall be allowed. Each bit represents a specific day of the week. If the bit is set to one (1), then the scheduled entry shall be allowed during the associated DOW. If the bit is set to zero (0), then the scheduled entry shall not be allowed during the associated DOW. The bits are defined as: Bit Day of Week 0 Reserved 1 Sunday 2 Monday 3 Tuesday 4 Wednesday 5 Thursday 6 Friday 7 Saturday" ::= { timeBaseScheduleEntry 3 } 2.4.3.2.4 Time Base Schedule Date Parameter timeBaseScheduleDate OBJECT-TYPE SYNTAX INTEGER (0..4294967295) ACCESS read-write STATUS mandatory DESCRIPTION "The Day(s) of a month that the schedule entry shall be allowed. Each bit represents a specific date of the month. If the bit is set to one (1), then the scheduled entry shall be allowed during the associated date. If the bit is set to zero (0), then the scheduled entry shall not be allowed during the associated date. The bits are defined as: Bit Day Number 0 Reserved 1 Day 1 2 Day 2 || 31 Day 31" ::= { timeBaseScheduleEntry 4 } 2.4.3.2.5 Time Base Schedule Day Plan Parameter timeBaseScheduleDayPlan OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies what Plan number shall be associated with this timeBaseScheduleDayPlan - object." ::= { timeBaseScheduleEntry 5 } 2.4.4 Day Plan Parameters 2.4.4.1 Maximum Number of Day Plans - Parameter maxDayPlans OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object specifies the maximum, fixed number of different timebased Day Plans supported by the device. The value of this object represents the number of day plans (primary key into the table) available in the timeBaseDayPlanTable." ::= { timebase 3 } 2.4.4.2 Maximum Number of Day Plan Events - Parameter maxDayPlanEvents OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object specifies the maximum, fixed number of different timebased Day Plan Events within each Day Plan supported by the device. The value of this object represents the number of rows (secondary key into the table) available within each of the day plans that are available in the timeBaseDayPlanTable." ::= { timebase 4 } 2.4.4.3 Day Plan Table timeBaseDayPlanTable OBJECT-TYPE SYNTAX SEQUENCE OF TimeBaseDayPlanEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing day plan numbers, the times when to implement them and the associated actions. The number of rows in this table shall not exceed the value of the maxDayPlans object. This table is always used in association with device-type specific objects specifying device-type specific actions such as activating a message on a VMS sign or initiating a pattern for a signal controller. The device-type specific action will only be initiated when the specific DayPlan has been activated and at the indicated time." ::= { timebase 5 } © 2001 NEMA Copy per MIB Distribution Notice timeBaseDayPlanEntry OBJECT-TYPE SYNTAX TimeBaseDayPlanEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing the timebased day plan parameters of a device." INDEX { dayPlanNumber, dayPlanEventNumber } ::= { timeBaseDayPlanTable 1 } TimeBaseDayPlanEntry ::= SEQUENCE { dayPlanNumber INTEGER, dayPlanEventNumber INTEGER, dayPlanHour INTEGER, dayPlanMinute INTEGER, dayPlanActionNumberOID OBJECT IDENTIFIER } 2.4.4.3.1 Day Plan Number dayPlanNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the day plan number for objects in this row. The value shall not exceed the value of the maxDayPlans object. Day plan numbers are used in the TimeBase Event Table to specify day plan numbers to be implemented on specific days of the year or as part of the week plans." ::= { timeBaseDayPlanEntry 1 } 2.4.4.3.2 Day Plan Event Number dayPlanEventNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies day plan event number(s) to be scheduled on a specific day plan number. Several different events can be scheduled to take place during a day, and each of these events is one entry or row within a specified day plan number. The total number of events for one day plan shall not exceed the value of the maxDayPlanEvents-object." ::= { timeBaseDayPlanEntry 2 } 2.4.4.3.3 Day Plan Hour Parameter dayPlanHour OBJECT-TYPE SYNTAX INTEGER (0..23) ACCESS read-write STATUS mandatory DESCRIPTION "The Hour of day that the associated event shall become active. Valid values for this object are 0 - 23 as the time shall be transmitted in military time." ::= { timeBaseDayPlanEntry 3 } 2.4.4.3.4 Day Plan Minute Parameter dayPlanMinute OBJECT-TYPE SYNTAX INTEGER (0..59) ACCESS read-write STATUS mandatory DESCRIPTION "The Minute of the hour (defined in the dayPlanHour) object that the associated event shall become active. Valid values for this object are 0 - 59 since there are only 0 - 59 minutes in an hour." ::= { timeBaseDayPlanEntry 4 } 2.4.4.3.5 Day Plan Action Number OID Parameter dayPlanActionNumberOID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the first index-column (if multi indexed tables are pointed to, all indices have to be specified within the OID) within a device-type specific action table that contains the actions (specified in the associated columns within the table) that shall be executed if the time indicated within the dayPlanTable and the timeBaseEventSchedule Table is the current time." ::= { timeBaseDayPlanEntry 5 } 2.4.4.4 Day Plan Status Parameter dayPlanStatus OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the current value of the active day PlanNumber-object. A value of zero (0) indicates that there is no dayPlanNumber that is currently active." ::= { timebase 6 } 2.4.5 Global Local Time Differential Parameter globalLocalTimeDifferential OBJECT-TYPE SYNTAX INTEGER (-43200..43200) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the number of seconds offset between local time and GMT. Positive values indicate local times in the Eastern Hemisphere up to the International Date Line and negative values indicate local times in the Western Hemisphere back to the International Date Line. If one of the daylight savings times is activated, this value will change automatically at the referenced time. For example, Central Standard Time (CST) is -21600 and Central Daylight Time (CDT) is - 18000." ::= { globalTimeManagement 4 } 2.5 REPORT PARAMETER NODE globalReport OBJECT IDENTIFIER ::= { global 4 } -- This node is an identifier used to organize all objects for support of report functions © 2001 NEMA Copy per MIB Distribution Notice -- that are common to most device types. 2.5.1 Maximum Event Log Configurations Parameter maxEventLogConfigs OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The number of rows that exist in the static eventLogConfig table for this device." ::= { globalReport 1 } 2.5.2 Event Log Configuration Table eventLogConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF EventLogConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing Event Log Configuration information. The number of rows in this table is equal to the maxEventLogConfigs object." ::= { globalReport 2 } eventLogConfigEntry OBJECT-TYPE SYNTAX EventLogConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This object defines an entry in the event log configuration table." INDEX { eventConfigID } ::= { eventLogConfigTable 1 } EventLogConfigEntry ::= SEQUENCE { eventConfigID INTEGER, eventConfigClass INTEGER, eventConfigMode INTEGER, eventConfigCompareValue INTEGER, eventConfigCompareValue2 INTEGER, eventConfigCompareOID OBJECT IDENTIFIER, eventConfigLogOID OBJECT IDENTIFIER, eventConfigAction INTEGER } 2.5.2.1 Event Log Configuration ID Parameter eventConfigID OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This object contains the row number which is used to identify the event associated with this row in the eventLogConfigTable. The number of event IDs shall not exceed the value indicated in the maxEventLogConfigs object. The value zero (0) is not allowed." ::= { eventLogConfigEntry 1 } 2.5.2.2 Event Log Configuration Class Parameter eventConfigClass OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "This object contains the class value to assign to the event associated with this row in the event configuration table. This value is used in the event log table to organize various events defined in this table into logical groupings." ::= { eventLogConfigEntry 2 } 2.5.2.3 Event Log Configuration Mode Parameter eventConfigMode OBJECT-TYPE SYNTAX INTEGER { other (1), onChange (2), greaterThanValue (3), smallerThanValue (4), hysteresisBound (5), periodic (6) } ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the mode of operation for this event. All checks and entries to the table must occur within one second of the condition becoming true. The modes are defined as follows: VALUE DESCRIPTION onChange create a log entry when value referenced by the eventTypeOID changes greaterThanValue create a log entry when the object value becomes greater than the value referenced to by the eventCompareValue object, if this value is exceeded for the amount of time specified in the eventConfigCompareValue2 object (in tenth of seconds) and this value is greater than zero (0). A value of zero (0) for eventConfigCompareValue2 indicates immediate logging. smallerThanValue create a log entry when the object value becomes less than the value referenced to by the eventCompareValue object, if this value is exceeded for the amount of time specified in the eventConfigCompareValue2 object (in tenth of seconds) and this value is greater than zero (0). A value of zero (0) for eventConfigCompareValue2 indicates immediate logging. hysteresisBound creates a log entry when the object value becomes either less than the lowerbound value or greater than the upperbound value. The lowerbound value is the lower value of the eventConfigCompareValue- and the eventConfigCompareValue2-objects, the upperbound is the other value. periodic create a log entry every x seconds, where x is defined by the value stored in eventConfigCompareValue. The values stored in eventConfigCompareValue2 and eventConfigCompareOID are ignored in this mode. " ::= { eventLogConfigEntry 3 } 2.5.2.4 Event Log Configuration Compare Value Parameter eventConfigCompareValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION © 2001 NEMA Copy per MIB Distribution Notice "This object contains the comparison value to use with eventConfigMode values (greaterThanValue, smallerThanValue, hysteresisBound ). No value within this object is necessary when the eventConfigMode-object has the “value onChange (2)." ::= { eventLogConfigEntry 4 } 2.5.2.5 Event Log Configuration Compare Value 2 Parameter eventConfigCompareValue2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "If the eventConfigMode is set to hysteresisBound, this object specifies the second comparison value for the hysteresis. If the eventConfigMode is set to greaterThanValue or smallerThanValue, this object specifies the time (in tenth of seconds) for which the comparison must be true prior to the event condition becoming true. If the eventConfigMode is set to onChange or periodic, the value of this object shall be ignored." ::= { eventLogConfigEntry 5 } 2.5.2.6 Event Log Configuration Compare Object Identifier Parameter eventConfigCompareOID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-write STATUS mandatory DESCRIPTION "This object contains the object identifier which references the value against which the comparison is made. If the eventConfigMode is set to periodic, the value of this object shall be ignored." ::= { eventLogConfigEntry 6 } 2.5.2.7 Event Log Configuration Object Identifier Parameter eventConfigLogOID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-write STATUS optional DESCRIPTION "This object contains the object identifier which indicates what value to log when a condition or event occurs (e.g., log the phase display when the watchdog alarm status changes)." ::= { eventLogConfigEntry 7 } 2.5.2.8 Event Log Configuration Action Parameter eventConfigAction OBJECT-TYPE SYNTAX INTEGER { other (1), disabled (2), log (3) } ACCESS read-write STATUS optional DESCRIPTION "This value of this object indicates the action that will take place when the event described in this row of the event configuration table occurs. disabled - no entry will be recorded due to this event. log - an entry will be recorded in the event log table when this event occurs." ::= { eventLogConfigEntry 8 } 2.5.3 Maximum Event Log Size Parameter maxEventLogSize OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The maximum, fixed number of rows that can be utilized within the Event Log Table." ::= { globalReport 3 } 2.5.4 Event Log Table eventLogTable OBJECT-TYPE SYNTAX SEQUENCE OF EventLogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing Event History data collected." ::= { globalReport 4 } eventLogEntry OBJECT-TYPE SYNTAX EventLogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This object defines an entry in the event log table" INDEX { eventLogClass, eventLogNumber } ::= { eventLogTable 1 } EventLogEntry ::= SEQUENCE { eventLogClass INTEGER, eventLogNumber INTEGER, eventLogID INTEGER, eventLogTime Counter, eventLogValue Opaque } 2.5.4.1 Event Log Class Parameter eventLogClass OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "This object contains the class of the associated event as defined in the eventLogConfig Table." ::= { eventLogEntry 1 } 2.5.4.2 Event Log Number Parameter eventLogNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "The event number within this class for this event. Event numbers shall be assigned starting at 1 and shall increase to the value specified by the associated eventClassLimit for the class associated with the rows. Events shall maintain a chronological ordering in the table with the oldest event of a class © 2001 NEMA Copy per MIB Distribution Notice occupying the row with eventNumber = 1, and subsequent events filling subsequent rows. This ordering shall be maintained when events are cleared." ::= { eventLogEntry 2 } 2.5.4.3 Event Log ID Parameter eventLogID OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This object contains the event configuration ID (from the eventLogConfigTable) that caused this table entry. It indicates the row in the eventLogConfig table responsible for this event entry. If this object is set to zero (0) then the associated row (in the eventLogTable) is cleared and the following rows shall be renumbered to maintain a sequential eventNumber sequence." ::= { eventLogEntry 3 } 2.5.4.4 Event Log Time Parameter eventLogTime OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The time that the event occurred in seconds since the epoch of 00:00:00 (midnight) January 1, 1970 per the device’s globalTime object. If the device does not have valid date and time information, then this shall be the time in seconds since the device powered up." ::= { eventLogEntry 4 } 2.5.4.5 Event Log Value Parameter eventLogValue OBJECT-TYPE SYNTAX Opaque ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is set to the value referenced by the eventConfigLogOID of the associated eventLogID when the event was logged. Its length is variable." ::= { eventLogEntry 5 } 2.5.5 Maximum Event Classes Parameter maxEventClasses OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "This object defines the maximum, fixed number of rows in the eventClassTable that this device supports. This places an upper limit on the number of classes that may be defined for events in this device." ::= { globalReport 5 } 2.5.6 Event Class Table eventClassTable OBJECT-TYPE SYNTAX SEQUENCE OF EventClassEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table is used to configure event logging limits and log table maintenance." ::= { globalReport 6 } eventClassEntry OBJECT-TYPE SYNTAX EventClassEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This defines a row in the Event Class Table" INDEX { eventClassNumber } ::= { eventClassTable 1 } EventClassEntry ::= SEQUENCE { eventClassNumber INTEGER, eventClassLimit INTEGER, eventClassClearTime Counter, eventClassDescription OCTET STRING, eventClassNumRowsInLog INTEGER } 2.5.6.1 Event Class Number Parameter eventClassNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "This is a class value that is to be configured." ::= { eventClassEntry 1 } 2.5.6.2 Event Class Limit Parameter eventClassLimit OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the maximum number of events of the associated class to store in the log. Once the limit is reached, the oldest entry of the matching class will be overwritten by any new entry of the same class. If the value of this object is set to a number smaller than the current number of rows within this class in the eventLogTable, then the oldest entries shall be lost/deleted." ::= { eventClassEntry 2 } 2.5.6.3 Event Class Clear Time Parameter eventClassClearTime OBJECT-TYPE SYNTAX Counter ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to clear multiple event log entries from the event log table. Setting this value shall cause all events of this class that have an eventTime equal to or less than this object to be cleared from the eventLog table. The time is the number of seconds since the epoch of 00:00:00 (midnight) January 1, 1970." © 2001 NEMA Copy per MIB Distribution Notice ::= { eventClassEntry 3 } 2.5.6.4 Event Class Description Parameter eventClassDescription OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS optional DESCRIPTION "This object specifies a description of the class in ASCII characters." ::= { eventClassEntry 4 } 2.5.6.5 Event Class Number of Rows in Event Log Table Parameter eventClassNumRowsInLog OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "The number of rows for this class that currently exist in the eventLogTable." ::= { eventClassEntry 5 } 2.6 STMP OBJECT NODE profilesSTMP OBJECT IDENTIFIER ::= { profiles 2 } --This node is an identifier used to group all objects for support of configuration functions -- that are common to device types that support the STMP protocol. The objects under this node are -- placed under the Protocols\Profiles\STMP subtree within the NEMA node, but they have been listed -- here due to the lack of a separate document that lists these objects. 2.6.1 Dynamic Object Persistence Parameter dynamicObjectPersistence OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The maximum power outage time in minutes that may occur before all STMP dynamic object definitions in a device shall be invalidated. If this object is set to zero then existing dynamic object definitions shall be invalidated on device power up. If this object is set to its maximum value (65535) the existing dynamic object definitions shall not be invalidated due to power outages of any duration. A device that supports STMP dynamic objects shall support this object." REFERENCE "NEMA TS 3.2 Clause 4.2.1.1" ::= { profilesSTMP 1 } 2.7 PMPP OBJECT NODE profilesPMPP OBJECT IDENTIFIER ::= { profiles 3 } -- This node is an identifier used to group all objects for support of the PMPP function that -- are common to all device types. The objects under this node are placed under the -- Protocols\Profiles\PMPP subtree within the NEMA node, but they have been listed here due to the lack -- of a separate document that lists these objects. 2.7.1 Maximum HDLC Group Address Parameter maxGroupAddresses OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of group addresses this device supports. This object indicates the maximum number of rows in the Data Link Layer group address table." ::= { profilesPMPP 1 } 2.7.2 HDLC Group Address Table hdlcGroupAddressTable OBJECT-TYPE SYNTAX SEQUENCE OF HdlcGroupAddressEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing group addresses at which a device may receive frames." ::= { profilesPMPP 2 } hdlcGroupAddressEntry OBJECT-TYPE SYNTAX HdlcGroupAddressEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the group address table that contains a device’s data link layer group address at which it will accept frames." INDEX { hdlcGroupAddressIndex } ::= { hdlcGroupAddressTable 1 } HdlcGroupAddressEntry ::= SEQUENCE { hdlcGroupAddressIndex INTEGER, hdlcGroupAddress INTEGER } 2.7.2.1 HDLC Group Address Index Parameter hdlcGroupAddressIndex OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "The index number for the group address in this row." ::= { hdlcGroupAddressEntry 1 } 2.7.2.2 HDLC Group Address Parameter hdlcGroupAddress OBJECT-TYPE SYNTAX INTEGER ACCESS read-write © 2001 NEMA Copy per MIB Distribution Notice STATUS mandatory DESCRIPTION "A group address for the data link layer. For PMPP, the syntax is an 8- or 16-bit entry with the second low order bit set to a one indicating that this is a group address." REFERENCE "NEMA TS 3.3 Clause 3.3.3.1" ::= { hdlcGroupAddressEntry 2 } 2.8 SECURITY NODE security OBJECT IDENTIFIER::={global 5} -- This node is an identifier used to group all objects related to the -- assignment of community names and the access rights they provide. 2.8.1 Community Name Administrator Parameter communityNameAdmin OBJECT-TYPE SYNTAX OCTET STRING (SIZE(8..16)) ACCESS read-write STATUS mandatory DESCRIPTION "This object is the community name that must be used to specifically gain access to information under the security node. A message with this value in the community name field of an SNMP message has user read-write access to the security node objects and all other objects implemented in the device. The syntax is defined as an OCTET STRING and therefore any character can have a value of 0..255." DEFVAL { "administrator" } ::= { security 1 } 2.8.2 Maximum Community Names Parameter communityNamesMax OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the maximum number of rows that are implemented in the community name table." ::= { security 2 } 2.8.3 Community Names Table communityNameTable OBJECT-TYPE SYNTAX SEQUENCE OF CommunityNameTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table defines the community names that can appear in the community name field of the SNMP message and access privileges associated with that community name." ::= { security 3 } communityNameTableEntry OBJECT-TYPE SYNTAX CommunityNameTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is the row index of information in the community name table." INDEX { communityNameIndex } ::= { communityNameTable 1 } CommunityNameTableEntry::=SEQUENCE { communityNameIndex INTEGER, communityNameUser OCTET STRING, communityNameAccessMask GAUGE } 2.8.3.1 Community Name Index Parameter communityNameIndex OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object defines the row index into the communityNameTable. This value shall not exceed the communityNamesMax object value." ::= { communityNameTableEntry 1 } 2.8.3.2 User Community Name Parameter communityNameUser OBJECT-TYPE SYNTAX OCTET STRING (SIZE(6..16)) ACCESS read-write STATUS mandatory DESCRIPTION "This object defines a community name value that a security administrator can assign user read-write access to information (other than security) in a device A message with this value in the community name field of an SNMP message has user access rights as defined in the communityNameAccessMask. The syntax is defined as an OCTET STRING and therefore any character can have a value of 0..255." DEFVAL { "public" } ::= { communityNameTableEntry 2 } 2.8.3.3 User Community Name Mask Parameter communityNameAccessMask OBJECT-TYPE SYNTAX GAUGE (0..4294967295) ACCESS read-write STATUS mandatory DESCRIPTION "This object defines a 32-bit mask that can be used to associate 'write access' with a community name. A value of 0x00000000 grants the community name user read-only access and overrides any individual object's read-write access clause. A value of OxFFFFFFFF grants the community name user read-write access and an individual object's read-write access clause applies. Values other 0x00000000 and 0xFFFFFFFF are implementation specific and may limit viewing and/or accessing the information in a device." DEFVAL { 4294967295 } ::= { communityNameTableEntry 3 } END