-- OIDref derived MIB transcription. Original PDF: https://www.ite.org/ITEORG/assets/File/Standards/1201v4-0-0.pdf -- Publisher front matter and notices follow as comments. -- A Joint Standard of AASHTO, ITE, and NEMA -- -- -- -- -- NTCIP 1201 v4.0.0 -- -- -- National Transportation -- Communications for ITS Protocol -- Global Object (GO) Definitions -- -- -- Published June 2025 -- -- -- -- -- Published by: -- -- American Association of State Highway and Transportation Officials (AASHTO) -- 555 12th Street, N.W., Suite 1000 -- Washington, D.C. 20004 -- -- Institute of Transportation Engineers (ITE) -- 1627 I Street, N.W., Suite 550 -- Washington, D.C. 20006 -- -- National Electrical Manufacturers Association (NEMA) -- 1300 17th Street N, #900 -- Arlington, VA 22209 -- -- -- --  2025 AASHTO / ITE / NEMA. All rights reserved. -- -- -- NOTICES -- -- Copyright Notice -- -- © 1997, 1999, 2005, 2011, 2025 by the American Association of State Highway and Transportation -- Of f icials (AASHTO), the Institute of Transportation Engineers (ITE), and the National Electrical -- Manuf acturers Association (NEMA). All intellectual property rights, including, but not limited to, the rights -- of reproduction, translation, and display are reserved under the laws of the United States of America, the -- Universal Copyright Convention, the Berne Convention, and the International and Pan American -- Copyright Conventions. Except as licensed or permitted, you may not copy these materials without prior -- written permission f rom AASHTO, ITE, or NEMA. Use of these materials does not grant any rights of -- ownership or claim of copyright. -- -- Visit www.ntcip.org For additional copyright inf ormation, instructions on requesting reprints of excerpts, -- and requests f or reproduction d the beyond the permissions granted below, visit www.ntcip.org. -- -- PDF File License Agreement -- -- To the extent that these materials are distributed by AASHTO / ITE / NEMA in the f orm of an Adobe® -- Portable Document Format (PDF) electronic f ile (the PDF f ile), AASHTO / ITE / NEMA authorizes each -- registered user to view, download, copy, or print the f ile f rom the authorized website, subject to the terms -- and conditions of this license agreement: -- -- a) You may download one copy of the PDF f ile f or personal, noncommercial, and intraorganizational -- use only. -- b) Ownership of the PDF f ile is not transf erred to you; you are licensed to use the PDF f ile. -- c) You may make one additional electronic copy of the PDF f ile, such as to a secondary hard drive -- or CD. -- d) You agree not to copy, distribute, or transf er the PDF f ile f rom that media to any other electronic -- media or device. -- e) You may print one paper copy of the PDF f ile. -- f ) You may make one paper reproduction of the printed copy. -- g) Any permitted copies must retain the copyright notice and all proprietary notices. -- h) The PDF f ile license does not include (1) resale of the PDF f ile or copies, (2) republishing the -- content in compendiums or anthologies, (3) publishing excerpts in commercial publications or -- works f or hire, (4) editing or modif ication of the PDF f ile except those portions as permitted, (5) -- posting on network servers or distribution by e- mail or f rom electronic storage devices, and (6) -- translation to other languages or conversion to other electronic f ormats. -- i) Other use of the PDF f ile and printed copy requires express, prior written consent. -- -- -- Data Dictionary and MIB Distribution Permission -- -- To the extent that these materials are distributed by AASHTO / ITE / NEMA in the f orm of a Data -- Dictionary ("DD") or Management Inf ormation Base ("MIB"), AASHTO / ITE / NEMA extend the f ollowing -- permission: -- -- You may make or distribute unlimited copies, in part or f ull, of the DD or MIB, including copies f or -- commercial distribution, provided that: -- -- 1. Each copy you make or distribute includes the citation "From NTCIP 0000 [insert the standard -- number]. Copyright by AASHTO / ITE / NEMA. Used by permission." -- 2. The copies are not edited f rom the published version of this document. -- -- These materials are delivered "AS IS," without any warranties regarding their use or perf ormance. -- -- AASHTO / ITE / NEMA and their suppliers do not warrant the performance or results you may -- obtain by using these materials. AASHTO / ITE / NEMA and their suppliers make no warranties, -- express or implied, as to noninfringement of third-party rights, merchantability, or fitness for any -- particular purpose. In no event will AASHTO / ITE / NEMA or their suppliers be liable to you or any -- third party for any claim or for any consequential, incidental or special damages, including any -- lost profits or lost savings, arising from your reproduction or use of these materials, even if an -- AASHTO / ITE / NEMA representative has been advised of the possibility of such damages. -- -- Some states or jurisdictions do not allow the exclusion or limitation of incidental, consequential, or special -- damages, or the exclusion of implied warranties, so the above limitations may not apply to a given user. -- -- Use of these materials does not constitute an endorsement or af f iliation by or between AASHTO, ITE, or -- NEMA and the user, the user's company, or the products and services of the user's company. -- -- If the user is unwilling to accept the f oregoing restrictions, he or she should immediately return these -- materials. -- -- Content and Liability Disclaimer -- -- The inf ormation in this publication was considered technically sound by the consensus of persons -- engaged in the development and approval of the document at the time it was developed. However, -- consensus does not imply unanimous agreement. among every person participating in the development -- of this document. -- -- AASHTO, ITE, and NEMA standards and guideline publications, of which the document contained herein -- is one, are developed through a voluntary consensus standards development process. This process -- brings together volunteers and seeks out the views of persons who have an interest in the topic covered -- by this publication. While AASHTO, ITE, and NEMA administer the process and establish rules to -- promote f airness in the development of consensus, they do not write the document and they do not -- independently test, evaluate, or verif y the accuracy or completeness of any inf ormation or the soundness -- of any judgments contained in their standards and guideline publications. -- -- AASHTO, ITE, and NEMA disclaim liability f or any personal injury, property, or other damages of any -- nature whatsoever, whether special, indirect, consequential, or compensatory, directly or indirectly -- resulting f rom the publication, use of , application, or reliance on this document. AASHTO, ITE, and NEMA -- disclaim and make no guaranty or warranty, express or implied, as to the accuracy or completeness of -- any inf ormation published herein and disclaims and makes no warranty that the inf ormation in this -- document will f ulf ill any of your purposes or needs. AASHTO, ITE, and NEMA do not undertake to -- guarantee the perf ormance of any individual manuf acturer or seller's products or services by virtue of this -- standard or guide. -- -- In publishing and making this document available, AASHTO, ITE, and NEMA are not undertaking to -- render prof essional or other services f or or on behalf of any person or entity, nor are AASHTO, ITE, and -- NEMA undertaking to perf orm any duty owed by any person or entity to someone else. Anyone using this -- document should rely on his or her own independent judgment or, as appropriate, seek the advice of a -- competent prof essional in determining the exercise of reasonable care in any given circumstance. -- Inf ormation and other standards on the topic covered by this publication may be available f rom other -- sources, which the user may wish to consult f or additional views or inf ormation not covered by this -- publication. -- -- AASHTO, ITE, and NEMA have no power, nor do they undertake to police or enf orce compliance with the -- contents of this document. AASHTO, ITE, and NEMA do not certif y, test, or inspect products, designs, or -- -- installations f or saf ety or health purposes. Any certif ication or other statement of compliance with any -- health or saf ety-related inf ormation in this document shall not be attributable to AASHTO, ITE, or NEMA -- and is solely the responsibility of the certif ier or maker of the statement. -- -- Trademark Notice -- -- NTCIP is a trademark of AASHTO / ITE / NEMA. All other trademarks mentioned in this standard belong -- to their respective owners. -- -- -- NTCIP 1201 v4.0.0 -- Page i -- -- -- -- ACKNOWLEDGEMENTS -- -- NTCIP 1201 v04 was prepared by the NTCIP Base Standards and Prof iles Working Group (BSP2 WG), a -- subdivision of the Joint Committee on the NTCIP. This committee operates under a Memorandum of -- Understanding among the American Association of State Highway and Transportation Of f icials -- (AASHTO), the Institute of Transportation Engineers (ITE), and the National Electrical Manuf acturers -- Association (NEMA). The Joint Committee on the NTCIP consists of six representatives f rom each -- standards development organization (SDO) and provides guidance f or NTCIP development. -- -- When this document was prepared, the f ollowing individuals were members of BSP2 WG: -- -- 1. Doug Crawf ord (Chair) 8. Robert Lopes -- 2. Steve Bostrom 9. Alex Mousadi -- 3. Wolf gang Buckel 10. Satya Muthuswamy -- 4. Michael Forbis 11. Bob Rausch -- 5. Joe Gorman 12. Rodney Schilling -- 6. Terry Haukom 13. Shea Tomsin -- 7. Patrick Leung 14. Walt Townsend -- -- -- Other individuals providing input include the f ollowing: -- -- 1. Md Ashraf Ahmed 18. Stephane Lapierre -- 2. Justin Anderson 19. Christopher Lyons -- 3. Kingsley Azubike 20. Gary Molnar -- 4. Ralph Boaz 21. Keith Patton -- 5. Russ Brookshire 22. Mahesh Pawar -- 6. Patrick Chan 23. Frank Perry -- 7. Stan Chow 24. Nu Rosenbohm -- 8. Deborah Curtis 25. Jay Schultz -- 9. Dustin DeVoe 26. Kellen Shain -- 10. Brian Doherty 27. Douglas Tarico -- 11. Edward Fok 28. Nicola Tavares -- 12. Sai Kiran Golla 29. John Thai -- 13. Jacob Grivette 30. Andrew Valdez -- 14. Mohammad Iraki 31. Kenneth Vaughn -- 15. Haydar Issa 32. Sankeer Vulupala -- 16. Denver Kruse 33. Robert White -- 17. AJ Lahiri -- -- -- In addition to the many volunteer ef f orts, recognition is also given to those organizations that supported -- the ef f orts of BSP2 WG by providing comments and f unding, including the f ollowing: -- -- 1. U.S. Department of Transportation, Research and Innovative Technology Administration -- 2. U.S. Department of Transportation, Federal Highway Administration -- 3. AECOM -- 4. Applied Inf ormation -- 5. City of Anaheim, CA -- 6. Consensus Systems Technologies -- 7. Caltrans -- 8. Daktronics -- 9. Econolite Control Products, Inc. -- 10. Florida Department of Transportation -- -- -- -- © 2025 AASHTO / ITE / NEMA Do Not Copy Without Written Permission -- -- NTCIP 1201 v4.0.0 -- Page ii -- -- 11. Georgia DOT -- 12. Kapsch -- 13. KLD Engineering -- 14. Michigan DOT -- 15. Minnesota DOT -- 16. Nevada DOT -- 17. Noblis -- 18. Parsons -- 19. Pillar Consulting -- 20. Q-Free -- 21. Siemens ITS -- 22. Signalisation Ver-Mac, Inc. -- 23. TransCore -- 24. Transport Canada -- 25. Trevilon -- 26. Washington State DOT -- 27. WSP -- -- -- -- -- Do Not Copy Without Written Permission © 2025 AASHTO / ITE / NEMA NTCIP1201-AuxIOv2 DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, OBJECT-IDENTITY, Integer32 FROM SNMPv2-SMI -- RFC 2578 DisplayString FROM SNMPv2-TC -- RFC 2579 global FROM NTCIP1201-Global; auxIOv2 MODULE-IDENTITY LAST-UPDATED "20230701145436Z" ORGANIZATION "NTCIP BSP2 WG" CONTACT-INFO "name: NTCIP Coordinator email: ntcip@nema.org postal: National Electrical Manufacturers Association 1300 North 17th Street, Suite 1752 Rosslyn, Virginia 22209-3801" DESCRIPTION " This MIB defines the SMIv2 representation of the AuxIOv2 objects that were previously defined in NTCIP 1201 v03. Auxiliary I/O was originally defined in NTCIP 1203 v01 under the experimental node. NTCIP 1201 v02 moved the objects to the location defined by this MIB but retained the same object names. Experience demonstrated challenges in compiling MIB files with duplicate object names and as a result NTCIP 1201 v03 changed the names of objects while retaining the NTCIP 1201 v02 object identifiers. NTCIP 1201 v04 deprecated these objects in favor of the general purpose I/O design defined in ISO 26048-1. For those agents that may support these objects and those originally defined under the experimental node (see Section 2.10), the object definitions are treated as aliases such that a write to an object in one group acts as write to the corresponding object in the other group. As aliases, a read of an object in this group is equivalent to a read of the corresponding object in the auxIO group. *** All objects in this MIB have been deprecated. *** 1.3.6.1.4.1.1206.4.2.6.7" REVISION "20230701145436Z" DESCRIPTION "NTCIP 1201 v04 - Upgraded format to SMIv2 and deprecated all objects." REVISION "200610020000Z" DESCRIPTION "NTCIP 1201 v03 - Created this as a standalone MIB. Changed all statuses to 'mandatory' to eliminate checking errors. Revised object names." ::= { global 7 } maxAuxIOv2TableNumDigitalPorts OBJECT-TYPE SYNTAX Integer32 (0..255) UNITS "digital ports" MAX-ACCESS read-only STATUS deprecated DESCRIPTION " The number of rows contained in the 'auxIOv2Table' with the auxIOv2PortType set to 'digital'. ISO26048-1-Srsa.fdSrsaTypeCount (ISO 26048-1) The GPIO count objects are managed by port type. 1.3.6.1.4.1.1206.4.2.6.7.1" ::= { auxIOv2 1 } maxAuxIOv2TableNumAnalogPorts OBJECT-TYPE SYNTAX Integer32 (0..255) UNITS "analog ports" MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The number of rows contained in the 'auxIOv2Table' with the auxIOv2PortType set to 'analog'. ISO26048-1-Srsa.fdSrsaTypeCount (ISO 26048-1) The GPIO count objects are managed by port type. 1.3.6.1.4.1.1206.4.2.6.7.2" ::= { auxIOv2 2 } auxIOv2Table OBJECT-TYPE SYNTAX SEQUENCE OF AuxIOv2Entry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "A table providing the means to access any non- mission- critical or non-safety-related auxiliary I/O of the controller, including reading inputs and setting outputs. The number of rows in this table equals the sum of the values of the 'maxAuxIOv2TableNumDigitalPorts' and 'maxAuxIOv2TableNumAnalogPorts' objects. This table shall not be used to control or monitor any safety related equipment. The electrical levels used by the ports are not standardized by auxIOv2Table objects; such information should be contained in the hardware manual. static ISO26048-1-Srsa.fdSrsaTable & FIELD-DEVICE-GPIO- MIB.fdGPIOPortTable (ISO 26048-1) The GPIO objects provide a summary table for each port type. 1.3.6.1.4.1.1206.4.2.6.7.3" ::= { auxIOv2 3 } auxIOv2Entry OBJECT-TYPE SYNTAX AuxIOv2Entry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "Parameters of the auxiliary I/O table. ISO26048-1-Srsa.fdSrsaEntry & FIELD-DEVICE-GPIO- MIB.fdGPIOPortEntry (ISO 26048-1) The GPIO tables add columns for a count for each port type, a summary status of each type of port, an indication of the units reported by the port, an indication of the minimum and maximum values that can be reliably reported by the port, minimum and maximum threshold values that indicate when an alarm should be raised, and a status object that indicates any availability or alarm conditions. 1.3.6.1.4.1.1206.4.2.6.7.3.1" INDEX { auxIOv2PortType, auxIOv2PortNumber } ::= { auxIOv2Table 1 } AuxIOv2Entry ::= SEQUENCE { auxIOv2PortType INTEGER, auxIOv2PortNumber INTEGER, auxIOv2PortDescription DisplayString, auxIOv2PortResolution INTEGER, auxIOv2PortValue INTEGER, auxIOv2PortDirection INTEGER, auxIOv2PortLastCommandedState INTEGER} auxIOv2PortType OBJECT-TYPE SYNTAX INTEGER{ other (1), analog (2), digital (3) } MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Indicates the type of auxiliary I/O, which can be analog or digital. ISO26048-1-Srsa.fdSrsaType (ISO 26048-1) The GPIO tables classify ports using a three-letter code. ISO 26048-1 defines 23 port types and additional port types can be defined by registering with ISO. Example port types currently defined include humidity, light intensity, temperature, battery current, battery voltage, battery charge, generator fuel level, generator engine speed, fan status, etc. From NTCIP 1201 v01 to NTCIP v02 of these objects, it was determined that ports are either digital, analog, or other. 1.3.6.1.4.1.1206.4.2.6.7.3.1.1" ::= { auxIOv2Entry 1 } auxIOv2PortNumber OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Indicates the port number for the associated port type. Port numbers are used sequentially from one to max for each port type. There can be a port 1 for analog port and port 1 for digital port. ISO26048-1-Srsa.fdSrsaPortNumber (ISO 26048-1) 1.3.6.1.4.1.1206.4.2.6.7.3.1.2" ::= { auxIOv2Entry 2 } auxIOv2PortDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Informational text field describing the device at the associated auxiliary I/O. ISO26048-1-Srsa.fdSrsaPortDescription (ISO 26048-1) The GPIO object is an SnmpAdminString, which supports multi- lingual text. In NTCIP 1203 v01, the SYNTAX SIZE was listed as (0..50). In NTCIP 1201 v02 and NTCIP 1201 v03, this was changed to (0..255). 1.3.6.1.4.1.1206.4.2.6.7.3.1.3" ::= { auxIOv2Entry 3 } auxIOv2PortResolution OBJECT-TYPE SYNTAX Integer32 (1..255) UNITS "bits" MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Defines number of bits used for the IO-port (e.g. width of digital, resolution of analog). Thus, this feature allows the digital monitoring (via NTCIP) of an analog port on the agent. In NTCIP 1203 v01, ACCESS was listed as read-write; however, in NTCIP 1201 v03, ACCESS changed to read-only . This changed because resolution is fixed by the hardware implementation and cannot be changed by the management station. The SYNTAX also changed from NTCIP 1201 v02 to NTCIP 1201 v03; it is now as it was originally under the experimental node defined in NTCIP 1203v01. This changed to address backward compatibility and the 'aliasing' between the version 1 objects (see Section 2.10) and the Version 02 objects. ISO26048-1-Srsa.fdSrsaPortMinValue & ISO26048-1- Srsa.fdSrsaPortMaxValue (ISO 26048-1) The GPIO table indicates the range over which values can be considered reliable. 1.3.6.1.4.1.1206.4.2.6.7.3.1.4" ::= { auxIOv2Entry 4 } auxIOv2PortValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS deprecated DESCRIPTION "For input or bidirectional ports, this contains the current value of the input. For output ports, this is the last commanded value of the port. A genError shall be generated, if this object is set and the port is an input. The actual value exchanged shall not exceed [2^(auxIOv2PortResolution): 1]; any SET operation to a value in excess of this number shall result in a genErr, and any GET response in excess of this value shall be considered erroneous. ISO26048-1-Srsa.fdSrsaPortValue (ISO 26048-1) The original specification defined this parameter using INTEGER (0..4294967295); however, by convention, INTEGERs are limited to the range (-2147483648..2147483647) in SNMPv1 and SNMPv3 enforces this limitation. Therefore, when presenting this object in SNMPv3, it is encoded as an Unsigned32 rather than an INTEGER (0..4294967295); proxy agents will need to address this encoding change within their implementation. The replacement object in the GPIO table supports a signed 32-bit integer, thereby allowing sensors to report negative values. 1.3.6.1.4.1.1206.4.2.6.7.3.1.5" ::= { auxIOv2Entry 5 } auxIOv2PortDirection OBJECT-TYPE SYNTAX INTEGER { output (1), input (2), bidirectional (3) } MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Indicates whether state of this port can be set (output), read (input) or both (bidirectional). ISO26048-1-Srsa.fdSrsaPortDirection (ISO 26048-1) 1.3.6.1.4.1.1206.4.2.6.7.3.1.6" ::= { auxIOv2Entry 6 } auxIOv2PortLastCommandedState OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "For bi-directional ports, this object indicates the last state to which the auxIOv2PortValue object was set. For output ports, this value shall always be equal to the auxIOv2PortValue object. For input ports, this value shall always be zero (0). ISO26048-1-Srsa.fdSrsaRequestedValue (ISO 26048-1) The original specification defined this parameter Using INTEGER (0..4294967295); however, by convention, INTEGERs Are limited to the range (-2147483648..2147483647) in SNMPv1 and SNMPv3 enforces this limitation. Therefore, when presenting this Object in SNMPv3, it is encoded as an Unsigned32 rather than an INTEGER (0..4294967295); proxy agents will need to address this encoding change within their implementation. The replacement object in the GPIO table supports a signed 32- bit integer, thereby allowing negative output values. 1.3.6.1.4.1.1206.4.2.6.7.3.1.7" ::= { auxIOv2Entry 7 } END