-- OIDref derived MIB transcription. Original PDF: https://www.ntcip.org/file/2018/11/NTCIP1209v0218jp.pdf -- Publisher front matter and notices follow as comments. -- A Joint Standard of AASHTO, ITE, and NEMA -- -- -- -- -- NTCIP 1209 version v02 -- -- National Transportation -- Communications for ITS Protocol -- Object Definitions for -- Transportation Sensor Systems (TSS) -- -- published in May 2014 -- -- This Adobe® PDF copy of an NTCIP standard is available at no-cost for a limited time through -- support from the U.S. DOT ITS Joint Program Office, whose assistance is gratefully -- acknowledged. -- -- -- -- -- Published by -- -- American Association of State Highway and Transportation Officials (AASHTO) -- 444 North Capitol Street, N.W., Suite 249 -- Washington, D.C. 20001 -- -- Institute of Transportation Engineers (ITE) -- 1627 I (“Eye”) Street, N.W., Suite 600 -- Washington, D.C. 20006 -- -- National Electrical Manufacturers Association (NEMA) -- 1300 North 17th Street, Suite 900 -- Rosslyn, Virginia 22209-3801 -- -- -- -- file version 1209 v02.18jpo 2014c --  2014 AASHTO / ITE / NEMA. All rights reserved. -- -- NOTICES -- -- -- Copyright Notice -- -- 2014 by the American Association of State Highway and Transportation Officials (AASHTO), the -- Institute of Transportation Engineers (ITE), and the National Electrical Manufacturers Association -- (NEMA). All intellectual property rights, including, but not limited to, the rights of reproduction, translation, -- and display are reserved under the laws of the United States of America, the Universal Copyright -- Convention, the Berne Convention, and the International and Pan American Copyright Conventions. -- Except as licensed or permitted, you may not copy these materials without prior written permission from -- AASHTO, ITE, or NEMA. Use of these materials does not give you any rights of ownership or claim of -- copyright in or to these materials. -- -- Visit www.ntcip.org for other copyright information, for instructions to request reprints of excerpts, and to -- request reproduction that is not granted below. -- -- -- PDF File License Agreement -- -- To the extent that these materials are distributed by AASHTO / ITE / NEMA in the form of an Adobe® -- Portable Document Format (PDF) electronic data file (the “PDF file”), AASHTO / ITE / NEMA authorizes -- each registered PDF file user to view, download, copy, or print the PDF file available from the authorized -- website, subject to the terms and conditions of this license agreement: -- -- a) you may download one copy of each PDF file for personal, noncommercial, and intraorganizational -- use only; -- b) ownership of the PDF file is not transferred to you; you are licensed to use the PDF file; -- c) you may make one more electronic copy of the PDF file, such as to a second hard drive or burn to a -- CD; -- d) you agree not to copy, distribute, or transfer the PDF file from that media to any other electronic -- media or device; -- e) you may print one paper copy of the PDF file; -- f) you may make one paper reproduction of the printed copy; -- g) any permitted copies of the PDF file must retain the copyright notice, and any other proprietary -- notices contained in the file; -- h) the PDF file license does not include (1) resale of the PDF file or copies, (2) republishing the content -- in compendiums or anthologies, (3) publishing excerpts in commercial publications or works for hire, -- (4) editing or modification of the PDF file except those portions as permitted, (5) posting on network -- servers or distribution by electronic mail or from electronic storage devices, and (6) translation to -- other languages or conversion to other electronic formats; -- i) other use of the PDF file and printed copy requires express, prior written consent. -- -- -- Data Dictionary and MIB Distribution Permission -- -- To the extent that these materials are distributed by AASHTO / ITE / NEMA in the form of a Data -- Dictionary (“DD”) or Management Information Base (“MIB”), AASHTO / ITE / NEMA extend the following -- permission: -- -- You may make or distribute unlimited copies, including derivative works, of the DD or MIB, including -- copies for commercial distribution, provided that: -- -- a) each copy you make or distribute includes the citation “Derived from NTCIP 0000 [insert the standard -- number]. Copyright by AASHTO / ITE / NEMA. Used by permission.”; -- -- b) the copies or derivative works are not made part of the standard publications or works offered by -- other standard developing organizations or publishers or as works-for-hire not associated with -- commercial hardware or software products intended for field implementation; -- c) use of the DD or MIB is restricted in that the syntax fields may only be modified to define: 1) a more -- restrictive subrange; or 2) a subset of the standard enumerated values; or 3) a set of retired and -- defined enumerated values for systems supporting multiversion interoperability; -- d) the description field may be modified but only to the extent that: 1) the more restrictive subrange is -- defined; and 2) only those bit values or enumerated values that are supported are listed. -- -- These materials are delivered “AS IS” without any warranties as to their use or performance. -- -- AASHTO / ITE / NEMA and their suppliers do not warrant the performance or results you may -- obtain by using these materials. AASHTO / ITE / NEMA and their suppliers make no warranties, -- express or implied, as to noninfringement of third party rights, merchantability, or fitness for any -- particular purpose. In no event will AASHTO / ITE / NEMA or their suppliers be liable to you or any -- third party for any claim or for any consequential, incidental or special damages, including any -- lost profits or lost savings, arising from your reproduction or use of these materials, even if an -- AASHTO / ITE / NEMA representative has been advised of the possibility of such damages. -- -- Some states or jurisdictions do not allow the exclusion or limitation of incidental, consequential, or special -- damages, or the exclusion of implied warranties, so the above limitations may not apply to a given user. -- -- Use of these materials does not constitute an endorsement or affiliation by or between AASHTO, ITE, or -- NEMA and the user, the user’s company, or the products and services of the user’s company. -- -- If the user is unwilling to accept the foregoing restrictions, he or she should immediately return these -- materials. -- -- -- PRL and RTM Distribution Permission -- -- To the extent that these materials are distributed by AASHTO / ITE / NEMA in the form of a Profile -- Requirements List (“PRL”) or a Requirements Traceability Matrix (“RTM”), AASHTO / ITE / NEMA extend -- the following permission: -- -- a) you may make or distribute unlimited copies, including derivative works of the PRL (then known as a -- Profile Implementation Conformance Statement (“PICS”)) or the RTM, provided that each copy you -- make or distribute contains the citation “Based on NTCIP 0000 [insert the standard number] PRL or -- RTM. Used by permission. Original text © AASHTO / ITE / NEMA.” -- b) you may only modify the PRL or the RTM by adding: 1) text in the Project Requirements column, -- which is the only column that may be modified to show a product’s implementation or the project- -- specific requirements; and/or 2) additional table columns or table rows that are clearly labeled as -- ADDITIONAL for project-unique or vendor-unique features; and -- c) if the PRL or RTM excerpt is made from an unapproved draft, add to the citation “PRL (or RTM) -- excerpted from a draft standard containing preliminary information that is subject to change.” -- -- This limited permission does not include reuse in works offered by other standards developing -- organizations or publishers, and does not include reuse in works-for-hire, compendiums, or electronic -- storage devices that are not associated with procurement documents, or commercial hardware, or -- commercial software products intended for field installation. -- -- A PICS is a Profile Requirements List that is completed to indicate the features that are supported in an -- implementation. Visit www.ntcip.org for information on electronic copies of the MIBs, PRLs, and RTMs. -- -- Content and Liability Disclaimer -- -- The information in this publication was considered technically sound by the consensus of persons -- engaged in the development and approval of the document at the time it was developed. Consensus -- does not necessarily mean that there is unanimous agreement among every person participating in the -- development of this document. -- -- AASHTO, ITE, and NEMA standards and guideline publications, of which the document contained herein -- is one, are developed through a voluntary consensus standards development process. This process -- brings together volunteers and seeks out the views of persons who have an interest in the topic covered -- by this publication. While AASHTO, ITE, and NEMA administer the process and establish rules to -- promote fairness in the development of consensus, they do not write the document and they do not -- independently test, evaluate, or verify the accuracy or completeness of any information or the soundness -- of any judgments contained in their standards and guideline publications. -- -- AASHTO, ITE, and NEMA disclaim liability for any personal injury, property, or other damages of any -- nature whatsoever, whether special, indirect, consequential, or compensatory, directly or indirectly -- resulting from the publication, use of, application, or reliance on this document. AASHTO, ITE, and NEMA -- disclaim and make no guaranty or warranty, express or implied, as to the accuracy or completeness of -- any information published herein, and disclaims and makes no warranty that the information in this -- document will fulfill any of your particular purposes or needs. AASHTO, ITE, and NEMA do not undertake -- to guarantee the performance of any individual manufacturer or seller’s products or services by virtue of -- this standard or guide. -- -- In publishing and making this document available, AASHTO, ITE, and NEMA are not undertaking to -- render professional or other services for or on behalf of any person or entity, nor are AASHTO, ITE, and -- NEMA undertaking to perform any duty owed by any person or entity to someone else. Anyone using this -- document should rely on his or her own independent judgment or, as appropriate, seek the advice of a -- competent professional in determining the exercise of reasonable care in any given circumstances. -- Information and other standards on the topic covered by this publication may be available from other -- sources, which the user may wish to consult for additional views or information not covered by this -- publication. -- -- AASHTO, ITE, and NEMA have no power, nor do they undertake to police or enforce compliance with the -- contents of this document. AASHTO, ITE, and NEMA do not certify, test, or inspect products, designs, or -- installations for safety or health purposes. Any certification or other statement of compliance with any -- health or safety-related information in this document shall not be attributable to AASHTO, ITE, or NEMA -- and is solely the responsibility of the certifier or maker of the statement. -- -- -- Trademark Notice -- -- NTCIP is a trademark of AASHTO / ITE / NEMA. All other marks mentioned in this standard are the -- trademarks of their respective owners. -- -- NTCIP 1209 v02.18 -- Page i -- -- -- ACKNOWLEDGEMENTS -- -- NTCIP 1209 v02 was prepared by the NTCIP Transportation Sensor Systems (TSS) Working Group, -- which is a subdivision of the Joint Committee on the NTCIP. The Joint Committee on the NTCIP is -- organized under a Memorandum of Understanding among the American Association of State Highway -- and Transportation Officials (AASHTO), the Institute of Transportation Engineers (ITE), and the National -- Electrical Manufacturers Association (NEMA). The Joint Committee on the NTCIP consists of six -- representatives from each of the standards organizations, and provides guidance for NTCIP -- development. -- -- At the time that NTCIP 1209 v02 was prepared, the following individuals were members of the NTCIP -- TSS Working Group: -- --  Ralph Boaz (Chair)  Lynne Randolph --  Terry Haukom  Mike Robertson --  Kyle Irvin  Robert Ung --  Allen Jacobs  Keith Vennel --  Peter Ragsdale  Jo Versavel -- -- In addition to the many volunteer efforts, recognition is also given to those organizations that supported -- the efforts of the NTCIP TSS Working Group by providing comments and resources, including: -- --  U.S. Department of Transportation, Joint  Minnesota Department of Transportation -- Program Office  Noblis --  3M Intelligent Transportation Systems  Ontario Ministry of Transportation --  California Department of Transportation  Peek Traffic Corp. --  Denver Regional Council of Governments  Pillar Consulting, Inc. --  Eberle Design, Inc.  Quixote Traffic Corp. --  Electronic Integrated Systems, Inc.  Reno A&E, Inc. --  Federal Highway Administration  Robert De Roche Consulting --  Golden River Traffic, Ltd.  Sciovid, Inc. --  Harris County Traffic & Transportation  Southwest Research Institute -- Department  Telvent Farradyne Inc. --  Image Sensing Systems, Inc.  Traficon, Inc. --  Iteris Roadway Sensors  U.S. Traffic Corp. --  Los Angeles Department of Transportation -- -- -- -- -- © 2014 AASHTO / ITE / NEMA Do Not Copy Without Written Permission -- -- NTCIP 1209 v02.18 -- Page ii -- -- FOREWORD -- -- NTCIP 1209 v02 defines the Transportation Sensor System (TSS) data elements that are supported by -- the National Transportation Communications for ITS Protocol (NTCIP). A TSS is defined as any system -- capable of detecting and communicating certain traffic parameters using NTCIP. -- -- The effort to develop NTCIP began with the 3-TS Transportation Management Systems and Associated -- Control Devices Section of the National Electrical Manufacturers Association (NEMA). Their original -- desire was to address a user need for extending the TS 2 standards for traffic control hardware to include -- standardized systems communication. Under the guidance of the Federal Highway Administration's -- (FHWA) NTCIP Steering Group, the NEMA effort was expanded to include the development of -- communications standards for all transportation field devices that could be used in Intelligent -- Transportation Systems (ITS) networks. -- -- In September 1996, a formal agreement was reached among NEMA, ITE, and AASHTO to jointly -- develop, approve, and maintain NTCIP standards. Under guidance of a Joint AASHTO / ITE / NEMA -- Committee on NTCIP, a Working Group was created to develop data element definitions for Advanced -- Systems Sensors. The first meeting of the Working Group was in August 1997. Discussions within the -- Working Group lead to renaming of the Working Group to Transportation Sensor Systems. -- -- The predecessor of NTCIP 1209 v02, NTCIP 1209:2005, NTCIP Data Element Definitions for -- Transportation Sensor Systems, defined data elements in ASN.1 using the SNMP Object Type Macro for -- devices that sense the presence or similar characteristics of vehicles. These definitions are intended for -- detection devices that range from smart inductive loop amplifiers to technologies such as machine vision. -- -- For more information about NTCIP standards, visit the NTCIP website at www.ntcip.org. -- -- -- User Comment Instructions -- -- The term “User Comment” includes any type of written inquiry, comment, question, or proposed revision, -- from an individual person or organization, about any part of this standards publication’s content. A -- “Request for Interpretation” of this standards publication is also classified as a User Comment. User -- Comments are solicited at any time. In preparation of this NTCIP standards publication, input of users -- and other interested parties was sought and evaluated. -- -- All User Comments are referred to the committee responsible for developing and/or maintaining NTCIP -- 1209 v02. The committee chairperson, or their designee, may contact the submitter for clarification of the -- User Comment. When the committee chairperson or designee reports the committee’s consensus opinion -- related to the User Comment, that opinion is forwarded to the submitter. The committee chairperson may -- report that action on the User Comment may be deferred to a future committee meeting and/or a future -- revision of the standards publication. Previous User Comments and their disposition may be available for -- reference and information at www.ntcip.org. -- -- A User Comment should be submitted to this address: -- -- NTCIP Coordinator -- National Electrical Manufacturers Association -- 1300 North 17th Street, Suite 900 -- Rosslyn, Virginia 22209-3801 -- e-mail: ntcip@nema.org -- -- -- -- -- Do Not Copy Without Written Permission © 2014 AASHTO / ITE / NEMA -- -- NTCIP 1209 v02.18 -- Page iii -- -- A User Comment should be submitted in the following form: -- -- Standards Publication number and version: -- Page: -- Section and Paragraph (with Table or Figure, where appropriate): -- Comment: -- Editorial or Substantive?: -- Suggested Alternative Language: -- -- Please include your name, organization, and address in your correspondence. -- -- -- Approvals -- -- NTCIP 1209 v02 was separately balloted and approved by AASHTO, ITE, and NEMA after -- recommendation by the Joint Committee on the NTCIP. Each organization has approved NTCIP 1209 -- v02 as the following standard type, as of the date: -- -- AASHTO—Standard Specification; June 2012 -- ITE—Software Standard; June 2011 -- NEMA—Standard; April 2011 -- -- -- History -- -- A brief history of NTCIP 1209 v02 follows: -- -- NTCIP 1209:2005 v01.19—Between 1999 and 2002, two user comment drafts were issued for -- review. In 2003, v01.18 was accepted as a Recommended Standard of the Joint Committee. In -- 2005, and after disposition of ballot comments, v01.18e was Jointly Approved. In November -- 2005, NTCIP 1209 v01.19 was published as NTCIP 1209:2005. -- -- NTCIP 1209 v02—Between 2004 and 2007, the TSS WG developed drafts with additional -- Systems Engineering content, and support for machine vision detection technology. In August -- 2007, the User Comment Draft NTCIP 1209 v02.10 was issued for user review and comment. In -- April 2008, after disposition of user comments, the NTCIP 1209 v02.15 was accepted as a -- Recommended Standard. In October 2010, after lifting a hold imposed by Normative References, -- NTCIP 1209 v02.17 was edited for SDO balloting and approval. In December 2010, NTCIP 1209 -- v02.17 was issued with NTCIP Standards Bulletin B0141. Following balloting and editing, NTCIP -- 1209 v02.18 was published. -- -- -- Compatibility of Versions -- -- To distinguish NTCIP 1209 v02 (as published) from previous drafts, NTCIP 1209 v02 also includes -- NTCIP 1209 v02.18 on each page header. All NTCIP Standards Publications have a major and minor -- version number for configuration management. The version number syntax is "v00.00a," with the major -- version number before the period, and the minor version number and edition letter (if any) after the -- period. -- -- NTCIP 1209 v02 is designated, and should be cited as, NTCIP 1209 v02. Anyone using NTCIP 1209 v02 -- should seek information about the version number that is of interest to them in any given circumstance. -- The MIB, the PRL, and the PICS should all reference the version number of the standards publication that -- was the source of the excerpted material. -- -- -- -- -- © 2014 AASHTO / ITE / NEMA Do Not Copy Without Written Permission -- -- NTCIP 1209 v02.18 -- Page iv -- -- Conformant systems based on later, or higher, version numbers MAY NOT be compatible with -- conformant systems based on earlier, or lower, version numbers. Anyone using NTCIP 1209 v02 should -- also consult NTCIP 8004 v02 for specific guidelines on compatibility. -- -- -- -- -- Do Not Copy Without Written Permission © 2014 AASHTO / ITE / NEMA NTCIP1209v02-MIB1 DEFINITIONS::= BEGIN IMPORTS IpAddress, Counter FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 DisplayString FROM RFC1213-MIB OwnerString, BITMAP8, BITMAP16, BITMAP32, tss FROM NTCIP8004-2008 -- Additional textual conventions. BITMAP64 ::= OCTET STRING (SIZE (8)) BITMAP96 ::= OCTET STRING (SIZE (12)) BITMAP256 ::= OCTET STRING (SIZE (32)) -- For the purpose of this section, the following OBJECT IDENTIFIERS -- are used: -- the node location is: nema / transportation tssSystemSetup OBJECT IDENTIFIER ::= { tss 1 } -- This node is an identifier used to group all objects for TSS sensor -- configurations that are common to all TSS. -- 1.3.6.1.4.1.1206.4.2.4.1 sensorSystemReset OBJECT-TYPE SYNTAX INTEGER { restart (1), reinitializeUserSettings (2), restoreFactoryDefaults (3), retune (4), resyncSamplingPeriods (5), shortDiagnostics (6), fullDiagnostics (7), executePendingConfiguration (8), abortPendingConfiguration (9), validatePendingConfiguration (10), noResetInProgress (11)} ACCESS read-write STATUS mandatory DESCRIPTION " A software interface to initiate a reset of various functions of the TSS. Execution of the command shall set this object to the value 0. The reset commands are described as follows: restart(1) - This command shall cause the unit to enter restart state and go through a complete shut-down and start-up process, causing a reset and initialization of the number of seconds since most recent TSS initialization to a value of zero. reinitializeUserSettings(2) – This command shall cause the unit to flush all memory and reinitialize all settings to their user-defined default values, and reset and initialize the number of seconds since most recent TSS initialization to a value of zero. restoreFactoryDefaults(3) - This command shall cause the unit to flush all memory, restore all settings to their factory default values, and reset and initialize the number of seconds since most recent TSS initialization to a value of zero. retune(4) – This command recalibrates unit background settings for all zones without resetting or flushing of any collected data. resyncSamplingPeriods(5) – This command shall cause the unit to synchronize all startup sampling period clocks within one (1) second of receiving the command and a reset and initialize of the number of seconds since most recent TSS initialization to a value of zero. shortDiagnostics(6) – This command shall cause the unit to go through an abbreviated vendor-specific diagnostic routine which may be the same as full diagnostics for some vendors. fullDiagnostics(7) – This command shall cause the unit to go through a complete vendor-specific diagnostic routine which may be the same as short diagnostics for some vendors, causing a reset and initialization of the number of seconds since most recent TSS initialization to a value of zero. executePendingConfiguration(8) – The behavior of this command is dependent upon type of configuration file uploaded and is manufacturer- specific. Execution may result in a system reboot, reinitialization, and loss of historical data. abortPendingConfiguration(9) – This command shall cause the TSS to cancel the currently pending configuration changes. validatePendingConfiguration(10) – This command is used to check the configuration to ensure that it is a valid configuration file. noResetInProgress(11) – No command is in-progress. All other commands shall set this object to this state upon completion. This value is read-only. 1.3.6.1.4.1.1206.4.2.4.1.1" ::= { tssSystemSetup 1 } sensorSystemStatus OBJECT-TYPE SYNTAX INTEGER { other (1), oK (2), initializing (3), pendingConfigurationChange (4), validatingPendingConfiguration (5), diagError (6), activeConfigError (7), pendingConfigError (8) } ACCESS read-only STATUS mandatory DESCRIPTION " This data element provides an indication of the overall sensor system status, as follows: other(1) - Indicates the presence of a hardware or software status that is not designated as either OK or initializing. oK(2) - Indicates that the unit is operating normally with no known hardware or software faults, with no implications about data. initializing(3) - Indicates that the unit has encountered no fault, but is not ready for detection. pendingConfigurationChange(4) - Indicates there is a new configuration that is implemented in the TSS upon the executePendingConfiguration command. validatingPendingConfiguration (5) - Indicates that the TSS is checking that the downloaded file is a valid configuration file. diagError (6) - Indicates that a hardware malfunction has been identified. activeConfigError (7) - Indicates that the current configuration being used in the TSS is invalid. pendingConfigError (8) - Indicates that the pending configuration file is invalid. 1.3.6.1.4.1.1206.4.2.4.1.2" ::= { tssSystemSetup 2 } sensorSystemOccupancyType OBJECT-TYPE SYNTAX INTEGER { normalizedOtherOccupancy (1), nonNormalizedOccupancy (2), zoneOccupancy (3), normalizedSixFootLoopOccupancy (4), normalizedTwoMeterLoopOccupancy (5), normalizedPointOccupancy (6)} ACCESS read-write STATUS mandatory DESCRIPTION " Indicates how to interpret the occupancy data of this TSS. normalizedOtherOccupancy(1) - Occupancy is normalized to other specific criteria that are not defined by other enumerated entries of this data element. Use of this enumeration should be done carefully as it could effect interoperability of equipment. nonNormalizedOccupancy(2) - Occupancy is presented as non-normalized or raw occupancy data. zoneOccupancy(3) - Occupancy is presented for a given zone. normalizedSixFootLoopOccupancy(4) - Occupancy is normalized to a 6-foot by 6-foot loop. normalizedTwoMeterLoopOccupancy(5) - Occupancy is normalized to a 2- meter by 2-meter loop. normalizedPointOccupancy(6) - Occupancy is normalized to a point. 1.3.6.1.4.1.1206.4.2.4.1.3" ::= { tssSystemSetup 3 } maxSensorZones OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " Indicates the maximum number of sensor zones supported by this TSS. 1.3.6.1.4.1.1206.4.2.4.1.4" ::= { tssSystemSetup 4 } sensorZoneTable OBJECT-TYPE SYNTAX SEQUENCE OF SensorZoneEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table containing sensor zone unit parameters. The number of rows in this table is equal to the maxSensorZones data element. Table rows are set by the manufacturer, and row creation/deletion is not supported. static 1.3.6.1.4.1.1206.4.2.4.1.5" ::= { tssSystemSetup 5} sensorZoneEntry OBJECT-TYPE SYNTAX SensorZoneEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Table for sensor zone parameters. 1.3.6.1.4.1.1206.4.2.4.1.5.1" INDEX { sensorZoneNumber } ::= { sensorZoneTable 1 } SensorZoneEntry ::= SEQUENCE { sensorZoneNumber INTEGER, sensorZoneOptions BITMAP8, sensorZoneOptionsStatus BITMAP8, sensorZoneSamplePeriod INTEGER, sensorZoneLabel OCTET STRING, sensorZoneAndOperator BITMAP64, sensorZoneOrOperator BITMAP64, sensorZonePairedZone INTEGER, sensorZonePairedZoneOptions BITMAP8, sensorZonePairedZoneSpacing INTEGER, sensorZoneSpeedCorrectionFactor INTEGER, sensorZoneAvgVehicleLength INTEGER, sensorZoneLength INTEGER, sensorZoneStatus INTEGER, sensorZoneNoActivityFaultTime INTEGER, sensorZoneMaxPresenceFaultTime INTEGER, sensorZoneErraticCountsFaultTime INTEGER, sensorZoneErraticCountsThreshold INTEGER } sensorZoneNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The numerical label or number of the sensor zone. This value shall not exceed the maxSensorZones data element value. sensorZoneNumber is used as an index for various data element tables. 1.3.6.1.4.1.1206.4.2.4.1.5.1.1" ::= { sensorZoneEntry 1 } sensorZoneOptions OBJECT-TYPE SYNTAX BITMAP8 ACCESS read-write STATUS mandatory DESCRIPTION " A bit-mapped value as defined below for commanding this sensor zone to be ENABLED or DISABLED. A non-configured system shall default to DISABLED. bit 7 0=DISABLED, 1=ENABLED To command this sensor zone to be enabled or disabled; bits 6..0 Reserved (bit 0=LSB) 1.3.6.1.4.1.1206.4.2.4.1.5.1.2" ::= { sensorZoneEntry 2 } sensorZoneOptionsStatus OBJECT-TYPE SYNTAX BITMAP8 ACCESS read-only STATUS mandatory DESCRIPTION " A bit-mapped value as defined below for indicating the status of whether this sensor zone is ENABLED or DISABLED. A zone options status may be disabled even though the status is set to enabled. This can occur if the sensor has automatically disabled a zone. Example: The TSS is a camera that has Pan/Tilt/Zoom control and the camera is temporarily moved for a surveillance operation. All of the zones on this camera would be automatically disabled until the camera had been returned to its original position. bit 7 0=DISABLED, 1=ENABLED To indicate the status of this sensor zone; bits 6..0 Reserved (bit 0=LSB). 1.3.6.1.4.1.1206.4.2.4.1.5.1.3" ::= { sensorZoneEntry 3 } sensorZoneSamplePeriod OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION " Duration of the sample period in seconds for the sensor zone over which time data is collected. Sample period durations from 0 to 3600 are available for use. Values from 3601 to 65535 are reserved for future use. A sampling period of zero (0) means that data is not being collected, while the sensor zone may continue to be enabled. second 1.3.6.1.4.1.1206.4.2.4.1.5.1.4" DEFVAL { 0 } ::= { sensorZoneEntry 4 } sensorZoneLabel OBJECT-TYPE SYNTAX OCTET STRING (SIZE(8..255)) ACCESS read-write STATUS optional DESCRIPTION " A text string used to describe the TSS sensor zone. A maximum string length of less than 255 may be supported. 1.3.6.1.4.1.1206.4.2.4.1.5.1.5" ::= { sensorZoneEntry 5 } sensorZoneAndOperator OBJECT-TYPE SYNTAX BITMAP64 ACCESS read-write STATUS optional DESCRIPTION " This data element identifies up to eight (8) unique zones that can be sequentially combined with a Boolean AND command to provide an input to this zone, as follows: Byte 1 Sensor zone number for the first Boolean AND combined with this zone, Byte 2 Sensor zone number for the second Boolean AND combined with this zone, Byte 3 Sensor zone number for the third Boolean AND combined with this zone, Byte 4 Sensor zone number for the fourth Boolean AND combined with this zone, Byte 5 Sensor zone number for the fifth Boolean AND combined with this zone, Byte 6 Sensor zone number for the sixth Boolean AND combined with this zone, Byte 7 Sensor zone number for the seventh Boolean AND combined with this zone, Byte 8 Sensor zone number for the eighth Boolean AND combined with this zone. Boolean AND combinations are processed before Boolean OR combinations. When read, this object returns last value written. -- This was TSS.orOperator:text in NTCIP 1209:2005 version v01. -- Corrected this typo because orOperator:text is used below. 1.3.6.1.4.1.1206.4.2.4.1.5.1.6" ::= { sensorZoneEntry 6 } sensorZoneOrOperator OBJECT-TYPE SYNTAX BITMAP64 ACCESS read-write STATUS optional DESCRIPTION " This data element identifies up to eight (8) unique zones that can be sequentially combined with a Boolean OR command to provide an input to this zone, as follows: Byte 1 Sensor zone number for the first Boolean OR combined with this zone, Byte 2 Sensor zone number for the second Boolean OR combined with this zone, Byte 3 Sensor zone number for the third Boolean OR combined with this zone, Byte 4 Sensor zone number for the fourth Boolean OR combined with this zone, Byte 5 Sensor zone number for the fifth Boolean OR combined with this zone, Byte 6 Sensor zone number for the sixth Boolean OR combined with this zone, Byte 7 Sensor zone number for the seventh Boolean OR combined with this zone, Byte 8 Sensor zone number for the eighth Boolean OR combined with this zone. Boolean AND combinations are processed before Boolean OR combinations. When read, this object returns last value written. 1.3.6.1.4.1.1206.4.2.4.1.5.1.7" ::= { sensorZoneEntry 7 } sensorZonePairedZone OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " This is a zone that provides additional information to the current zone for features that require a sequenced second zone to determine direction of travel or time of travel (e.g., speed trap, wrong way, etc.) 1.3.6.1.4.1.1206.4.2.4.1.5.1.8" ::= { sensorZoneEntry 8 } sensorZonePairedZoneOptions OBJECT-TYPE SYNTAX BITMAP8 ACCESS read-write STATUS mandatory DESCRIPTION " A bit-mapped value as defined below for indicating the status of the options for a paired zone. bit 0 0=OFF, 1=ON For a Sensor Zone operating in pairs the Zone Placement Option ON indicates that the zone is the leading zone of the pair and Zone Placement Option OFF indicates that the zone is a trailing zone in the pair. bit 1 0=OFF, 1=ON For a Sensor Zone operating in pairs the Single Zone Speed Mode Option is only used when there is an error on one of the paired zones. This parameter identifies how the TSS should calculate speed without the other zone. OFF indicates a manufacturer specific calculation and a Single Zone Speed Mode Option ON indicates the use of the calculation Speed = (Average Vehicle Length + Zone Length) / Detect Time. 1.3.6.1.4.1.1206.4.2.4.1.5.1.9" ::= { sensorZoneEntry 9 } sensorZonePairedZoneSpacing OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION " This parameter allows the user to set the spacing between paired zones for use in calculating vehicle speeds. This parameter is usually measured from the leading edge of one zone to the leading edge of the paired zone. 1.3.6.1.4.1.1206.4.2.4.1.5.1.10" ::= { sensorZoneEntry 10 } sensorZoneSpeedCorrectionFactor OBJECT-TYPE SYNTAX INTEGER (1..20000) ACCESS read-write STATUS mandatory DESCRIPTION " This is a percent multiplier for speed calculations within the TSS that is used to fine tune the accuracy of the reported speed. A setting of 1000 would be a multiplier of 1.000. one one-thousandth of a percent 1.3.6.1.4.1.1206.4.2.4.1.5.1.11" ::= { sensorZoneEntry 11 } sensorZoneAvgVehicleLength OBJECT-TYPE SYNTAX INTEGER (1..4000) ACCESS read-write STATUS mandatory DESCRIPTION " This parameter allows the user to set the average vehicle length for use in determining speed and classification. This allows for a range of lengths between 0.01 meters to 40 meters in length. one-hundredth of a meter 1.3.6.1.4.1.1206.4.2.4.1.5.1.12" ::= { sensorZoneEntry 12} sensorZoneLength OBJECT-TYPE SYNTAX INTEGER (1..4000 | 65535) ACCESS read-write STATUS mandatory DESCRIPTION " This parameter allows the user to set the length of the sensor zone. The value of 65535 shall be returned to represent no zone length set. This allows for a range of lengths between 0.01 meters to 40 meters in length. one-hundredth of a meter 1.3.6.1.4.1.1206.4.2.4.1.5.1.13" ::= { sensorZoneEntry 13 } sensorZoneStatus OBJECT-TYPE SYNTAX INTEGER { other (1), oK (2), initializing (3), noActivity (4), maxPresence (5), configurationError (6), erraticCounts (7), disabled (8), overrideActive (9), sensorFailure (10), inputDataIntegrity (11), poorContrast (12), detectionAutoSuspended (13), pairedZoneFault (14) } ACCESS read-only STATUS mandatory DESCRIPTION " Detailed status returned as result of diagnostics, as follows: Value Meaning other(1) - Indicates an error has occurred within the TSS for which there is no defined definition within this data element. oK(2) - Indicates no other status values apply. initializing(3) - Indicates an initialization or diagnostics procedure is in-progress. noActivity(4) - Indicates no activity condition. maxPresence(5) - Indicates max presence condition. configurationError(6) - Indicates an error within the TSS configuration setup. erraticCounts(7 )- Indicates erratic counts. disabled(8) - Indicates that the zone is disabled. overrideActive(9) - Indicates an override is active. sensorFailure(10) - Indicates a sensing element failure. inputDataIntegrity(11) - Indicates input values are not sufficient to determine detector data accurately (e.g., bad communications, invalid video for machine vision) poorContrast(12) - Indicates insufficient contrast error condition. detectionAutoSuspended(13) - Indicates that the detection zone was automatically disabled by the TSS (e.g., camera is on a PTZ and was moved). pairedZoneFault(14) - Indicates that there was no problem with this zone, but a zone that it is paired with had a fault. This may affect the accuracy of data reported by this zone. If a condition occurs during the sample period, then that state remains for the duration of that sample period. If multiple conditions occur during a sample period, the last reported condition, other than OK, is retained. 1.3.6.1.4.1.1206.4.2.4.1.5.1.14" ::= { sensorZoneEntry 14 } sensorZoneNoActivityFaultTime OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION " Time period in seconds for the sensor zone during which, if there is no activity for the zone, a No Activity status is generated for the zone. A no activity fault time of zero (0) means that a no activity status cannot be generated for this sensor zone. second 1.3.6.1.4.1.1206.4.2.4.1.5.1.15" DEFVAL { 0 } ::= { sensorZoneEntry 15 } sensorZoneMaxPresenceFaultTime OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION " Time period in seconds for the sensor zone during which, if there is constant activity for the zone, a Max Presence status is generated for the zone. A max presence fault time of zero (0) means that a max presence status cannot be generated for this sensor zone. second 1.3.6.1.4.1.1206.4.2.4.1.5.1.16" DEFVAL { 0 } ::= { sensorZoneEntry 16 } sensorZoneErraticCountsFaultTime OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION " Time period in seconds for the sensor zone during which, if the Erratic Counts Threshold is created for the zone, an Erratic Counts status is generated for the zone. An erratic counts fault time of zero (0) means that an erratic counts status cannot be generated for this sensor zone. second 1.3.6.1.4.1.1206.4.2.4.1.5.1.17" DEFVAL { 0 } ::= { sensorZoneEntry 17 } sensorZoneErraticCountsThreshold OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION " The counts that if a sensor zone’s number of actuations meets or exceeds within the Erratic Counts Fault Time an Erratic Counts status is generated for the zone. An erratic counts threshold of zero (0) means that an erratic counts status cannot be generated for this sensor zone. count 1.3.6.1.4.1.1206.4.2.4.1.5.1.18" DEFVAL { 0 } ::= { sensorZoneEntry 18 } clockAvailable OBJECT-TYPE SYNTAX INTEGER { clockYes (1), clockNo (2) } ACCESS read-only STATUS mandatory DESCRIPTION " Indicates availability of a real time clock within the TSS so that time can be referenced to CTime. clockYes(1) - A real time clock is provided within the TSS, conformant with the applicable requirements for managing time in NTCIP 1201 v03, and time is referenced to actual local time within the device. clockNo(2) - A real time clock is not provided within the TSS and time is expressed in the number of seconds since most recent TSS initialization. 1.3.6.1.4.1.1206.4.2.4.1.6" ::= { tssSystemSetup 6 } sensorTechnology OBJECT-TYPE SYNTAX INTEGER { other (1), inductiveLoop (2), machineVision (3) } ACCESS read-only STATUS mandatory DESCRIPTION " Indicates the sensor technology used by this TSS. other(1) - Any TSS that is not currently covered by this standard. (e.g., microwave detectors) inductive loop (2) - A physical detector of coiled wire that is embedded in the driving surface that senses changes in magnetic field as vehicles pass over. machine vision (3) - A non intrusive detection methodology where in a video image of the driving surface is processed to determine the passage of a vehicle. 1.3.6.1.4.1.1206.4.2.4.1.7" ::= { tssSystemSetup 7 } maxSampleDataEntries OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-only STATUS mandatory DESCRIPTION " Indicates the maximum number of historical data entries per zone supported by the TSS. 1.3.6.1.4.1.1206.4.2.4.1.8" ::= { tssSystemSetup 8 } maxNumberOfCharacters OBJECT-TYPE SYNTAX INTEGER (8..255) ACCESS read-only STATUS mandatory DESCRIPTION " The maximum number of characters per identifier label that the TSS supports. 1.3.6.1.4.1.1206.4.2.4.1.9" ::= { tssSystemSetup 9 } functionalCapabilities OBJECT-TYPE SYNTAX BITMAP8 ACCESS read-only STATUS mandatory DESCRIPTION " A bit-mapped value as defined below for identifying the functional capabilities of the TSS. bit 0 0=NOT SUPPORTED, 1=SUPPORTED Sampling Features bit 1 0=NOT SUPPORTED, 1=SUPPORTED Timing Features bit 2 0=NOT SUPPORTED, 1=SUPPORTED Speed Features bits 3..7 Reserved (bit 7=MSB) 1.3.6.1.4.1.1206.4.2.4.1.10" ::= { tssSystemSetup 10 } externalArmingInputs OBJECT-TYPE SYNTAX BITMAP64 ACCESS read-write STATUS optional DESCRIPTION " This allows other devices to modify the states of the Arming Input Bits used by the TSS. There are separate clears and sets so that multiple TSSs could maintain the states of individual Arming Input Bits. It is envisioned that the first 24 bits would correspond to the Greens, Yellows, and Reds of phases 1 through 8 from the traffic signal controller. The last 8 bits would be used for other phases, overlaps, or special functions. If the Arming Pin inputs are DC then a low input is an ON and a high input is an OFF. If the Arming Pin inputs are AC then a low input is an OFF and a high input is an ON. byte 1 Bit 0 = Clear Arming Input bit 1, Bit 1 = Clear Arming Input bit 2, Bit 2 = Clear Arming Input bit 3, Bit 3 = Clear Arming Input bit 4, Bit 4 = Clear Arming Input bit 5, Bit 5 = Clear Arming Input bit 6, Bit 6 = Clear Arming Input bit 7, Bit 7 = Clear Arming Input bit 8, byte 2 Bit 0 = Clear Arming Input bit 9, Bit 1 = Clear Arming Input bit 10, Bit 2 = Clear Arming Input bit 11, Bit 3 = Clear Arming Input bit 12, Bit 4 = Clear Arming Input bit 13, Bit 5 = Clear Arming Input bit 14, Bit 6 = Clear Arming Input bit 15, Bit 7 = Clear Arming Input bit 16, byte 3 Bit 0 = Clear Arming Input bit 17, Bit 1 = Clear Arming Input bit 18, Bit 2 = Clear Arming Input bit 19, Bit 3 = Clear Arming Input bit 20, Bit 4 = Clear Arming Input bit 21, Bit 5 = Clear Arming Input bit 22, Bit 6 = Clear Arming Input bit 23, Bit 7 = Clear Arming Input bit 24, byte 4 Bit 0 = Clear Arming Input bit 25, Bit 1 = Clear Arming Input bit 26, Bit 2 = Clear Arming Input bit 27, Bit 3 = Clear Arming Input bit 28, Bit 4 = Clear Arming Input bit 29, Bit 5 = Clear Arming Input bit 30, Bit 6 = Clear Arming Input bit 31, Bit 7 = Clear Arming Input bit 32, byte 5 Bit 0 = Set Arming Input bit 1, Bit 1 = Set Arming Input bit 2, Bit 2 = Set Arming Input bit 3, Bit 3 = Set Arming Input bit 4, Bit 4 = Set Arming Input bit 5, Bit 5 = Set Arming Input bit 6, Bit 6 = Set Arming Input bit 7, Bit 7 = Set Arming Input bit 8, byte 6 Bit 0 = Set Arming Input bit 9, Bit 1 = Set Arming Input bit 10, Bit 2 = Set Arming Input bit 11, Bit 3 = Set Arming Input bit 12, Bit 4 = Set Arming Input bit 13, Bit 5 = Set Arming Input bit 14, Bit 6 = Set Arming Input bit 15, Bit 7 = Set Arming Input bit 16, byte 7 Bit 0 = Set Arming Input bit 17, Bit 1 = Set Arming Input bit 18, Bit 2 = Set Arming Input bit 19, Bit 3 = Set Arming Input bit 20, Bit 4 = Set Arming Input bit 21, Bit 5 = Set Arming Input bit 22, Bit 6 = Set Arming Input bit 23, Bit 7 = Set Arming Input bit 24, byte 8 Bit 0 = Set Arming Input bit 25, Bit 1 = Set Arming Input bit 26, Bit 2 = Set Arming Input bit 27, Bit 3 = Set Arming Input bit 28, Bit 4 = Set Arming Input bit 29, Bit 5 = Set Arming Input bit 30, Bit 6 = Set Arming Input bit 31, Bit 7 = Set Arming Input bit 32, 1.3.6.1.4.1.1206.4.2.4.1.11" ::= { tssSystemSetup 11 } -- The outputConditioningTable replaces the loopOutputConditioningTable that -- is used in NTCIP 1209:2005 version v01. outputConditioningTable OBJECT-TYPE SYNTAX SEQUENCE OF OutputConditioningEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Each table row contains objects for configuring detector sensor zone outputs. The number of rows in this table is equal to maxSensorZones. Table rows are set by the manufacturer, and row creation/deletion is not supported. static Each table row contains inductive loop detector sensor zone output conditioning parameters. 1.3.6.1.4.1.1206.4.2.4.1.12.1" INDEX { sensorZoneNumber } ::= { outputConditioningTable 1 } OutputConditioningEntry ::= SEQUENCE { sensorZoneOutputMode INTEGER, sensorZoneMaxPresenceTime INTEGER, sensorZoneOutputDelayTime INTEGER, sensorZoneOutputDelayMode INTEGER, sensorZoneOutputDelayEnables BITMAP96, sensorZoneOutputExtendTime INTEGER, sensorZoneOutputExtendMode INTEGER, sensorZoneOutputExtendEnables BITMAP96, sensorZoneOutputSequenced INTEGER } sensorZoneOutputMode OBJECT-TYPE SYNTAX INTEGER { other (1), pulse (2), presence (3), invalid (255) } ACCESS read-write STATUS mandatory DESCRIPTION " This object sets the length of the output during a detect condition. These detect outputs are described as follows: other(1) - Other – an output mode other than that defined in NTCIP 1209 v02. pulse(2) - Pulse - a pulse of 125ms (25ms) is output when a vehicle is detected. presence(3) - Presence - the output lasts the duration of a detect condition or until the detector tunes out the detect signal. Invalid(255) – Invalid data - Something has invalid data. 1.3.6.1.4.1.1206.4.2.4.1.12.1.1" ::= { outputConditioningEntry 1 } sensorZoneMaxPresenceTime OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS optional DESCRIPTION " This object sets the maximum time that the zone holds presence before retuning. Values of 1 to 65534 seconds are available. A value of 0 disables this timer and prevents a sensor zone occupancy from being tuned out at the end of a specific time. A value of 65,535 represents invalid data. second 1.3.6.1.4.1.1206.4.2.4.1.12.1.2" ::= { outputConditioningEntry 2 } sensorZoneOutputDelayTime OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS optional DESCRIPTION " The output for the zone is delayed from start of sensor zone occupancy by the time specified (tenths of a second: 00.0 to 6553.5 sec). For the output to actually switch, the sensor zone occupancy is required to be continuous and still be present at the end of the delay time. tenths of a second 1.3.6.1.4.1.1206.4.2.4.1.12.1.3" REFERENCE "NEMA TS2 Clause 3.5.5.5.4.c and 6.5.2.24.1" ::= { outputConditioningEntry 3 } sensorZoneOutputDelayMode OBJECT-TYPE SYNTAX INTEGER { delayEnablesHaveNoEffect (1), delayEnablesORedActive (2), delayEnablesORedNotActive (3), delayEnablesANDedActive (4), delayEnablesANDedNotActive (5) } ACCESS read-write STATUS optional DESCRIPTION " This parameter determines if and how the delay enables are used to modify the operation of the delay feature. delayEnablesHaveNoEffect(1) – The delay enables have no effect on the delay feature of the zone. delayEnablesORedActive(2) - If any of the delay enables are active the delay feature is active, else the delay feature is not active. delayEnablesORedNotActive(3) - If any of the delay enables are active the delay feature is not active, else the delay feature is inactive. delayEnablesANDedActive(4) - If all of the delay enables are active the delay feature is active, else the delay feature is not active. delayEnablesANDedNotActive(5) - If all of the delay enables are active the delay feature is not active, else the delay feature is active. 1.3.6.1.4.1.1206.4.2.4.1.12.1.4" ::= { outputConditioningEntry 4 } sensorZoneOutputDelayEnables OBJECT-TYPE SYNTAX BITMAP96 ACCESS read-write STATUS optional DESCRIPTION " This bit-mapped parameter identifies which Arming Pins, Arming Input Bits, and which state for each are to be used as enables for the delay feature. If the Arming Pin inputs are DC then a low input is an ON and a high input is an OFF. If the Arming Pin inputs are AC then a low input is an OFF and a high input is an ON. byte 1 Bit 0 = Arming Pin 1 OFF, Bit 1 = Arming Pin 2 OFF, Bit 2 = Arming Pin 3 OFF, Bit 3 = Arming Pin 4 OFF, Bit 4 = Arming Pin 5 OFF, Bit 5 = Arming Pin 6 OFF, Bit 6 = Arming Pin 7 OFF, Bit 7 = Arming Pin 8 OFF, byte 2 Bit 0 = Arming Pin 9 OFF, Bit 1 = Arming Pin 10 OFF, Bit 2 = Arming Pin 11 OFF, Bit 3 = Arming Pin 12 OFF, Bit 4 = Arming Pin 13 OFF, Bit 5 = Arming Pin 14 OFF, Bit 6 = Arming Pin 15 OFF, Bit 7 = Arming Pin 16 OFF, byte 3 Bit 0 = Arming Pin 1 ON, Bit 1 = Arming Pin 2 ON, Bit 2 = Arming Pin 3 ON, Bit 3 = Arming Pin 4 ON, Bit 4 = Arming Pin 5 ON, Bit 5 = Arming Pin 6 ON, Bit 6 = Arming Pin 7 ON, Bit 7 = Arming Pin 8 ON, byte 4 Bit 0 = Arming Pin 9 ON, Bit 1 = Arming Pin 10 ON, Bit 2 = Arming Pin 11 ON, Bit 3 = Arming Pin 12 ON, Bit 4 = Arming Pin 13 ON, Bit 5 = Arming Pin 14 ON, Bit 6 = Arming Pin 15 ON, Bit 7 = Arming Pin 16 ON, byte 5 Bit 0 = Arming Input bit 1 OFF, Bit 1 = Arming Input bit 2 OFF, Bit 2 = Arming Input bit 3 OFF, Bit 3 = Arming Input bit 4 OFF, Bit 4 = Arming Input bit 5 OFF, Bit 5 = Arming Input bit 6 OFF, Bit 6 = Arming Input bit 7 OFF, Bit 7 = Arming Input bit 8 OFF, byte 6 Bit 0 = Arming Input bit 9 OFF, Bit 1 = Arming Input bit 10 OFF, Bit 2 = Arming Input bit 11 OFF, Bit 3 = Arming Input bit 12 OFF, Bit 4 = Arming Input bit 13 OFF, Bit 5 = Arming Input bit 14 OFF, Bit 6 = Arming Input bit 15 OFF, Bit 7 = Arming Input bit 16 OFF, byte 7 Bit 0 = Arming Input bit 17 OFF, Bit 1 = Arming Input bit 18 OFF, Bit 2 = Arming Input bit 19 OFF, Bit 3 = Arming Input bit 20 OFF, Bit 4 = Arming Input bit 21 OFF, Bit 5 = Arming Input bit 22 OFF, Bit 6 = Arming Input bit 23 OFF, Bit 7 = Arming Input bit 24 OFF, byte 8 Bit 0 = Arming Input bit 25 OFF, Bit 1 = Arming Input bit 26 OFF, Bit 2 = Arming Input bit 27 OFF, Bit 3 = Arming Input bit 28 OFF, Bit 4 = Arming Input bit 29 OFF, Bit 5 = Arming Input bit 30 OFF, Bit 6 = Arming Input bit 31 OFF, Bit 7 = Arming Input bit 32 OFF, byte 9 Bit 0 = Arming Input bit 1 ON, Bit 1 = Arming Input bit 2 ON, Bit 2 = Arming Input bit 3 ON, Bit 3 = Arming Input bit 4 ON, Bit 4 = Arming Input bit 5 ON, Bit 5 = Arming Input bit 6 ON, Bit 6 = Arming Input bit 7 ON, Bit 7 = Arming Input bit 8 ON, byte 10 Bit 0 = Arming Input bit 9 ON, Bit 1 = Arming Input bit 10 ON, Bit 2 = Arming Input bit 11 ON, Bit 3 = Arming Input bit 12 ON, Bit 4 = Arming Input bit 13 ON, Bit 5 = Arming Input bit 14 ON, Bit 6 = Arming Input bit 15 ON, Bit 7 = Arming Input bit 16 ON, byte 11 Bit 0 = Arming Input bit 17 ON, Bit 1 = Arming Input bit 18 ON, Bit 2 = Arming Input bit 19 ON, Bit 3 = Arming Input bit 20 ON, Bit 4 = Arming Input bit 21 ON, Bit 5 = Arming Input bit 22 ON, Bit 6 = Arming Input bit 23 ON, Bit 7 = Arming Input bit 24 ON, byte 12 Bit 0 = Arming Input bit 25 ON, Bit 1 = Arming Input bit 26 ON, Bit 2 = Arming Input bit 27 ON, Bit 3 = Arming Input bit 28 ON, Bit 4 = Arming Input bit 29 ON, Bit 5 = Arming Input bit 30 ON, Bit 6 = Arming Input bit 31 ON, Bit 7 = Arming Input bit 32 ON, 1.3.6.1.4.1.1206.4.2.4.1.12.1.5" ::= { outputConditioningEntry 5 } sensorZoneOutputExtendTime OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION " The output for the zone is extended, after the end of the period in which the sensor zone is occupied, by the amount of time specified (tenths of a second: 00.0 to 6553.5 sec). tenths of a second 1.3.6.1.4.1.1206.4.2.4.1.12.1.6" REFERENCE "NEMA TS2 Clause 3.5.5.5.4.d and 6.5.2.24.2" ::= { outputConditioningEntry 6 } sensorZoneOutputExtendMode OBJECT-TYPE SYNTAX INTEGER { extendEnablesHaveNoEffect (1), extendEnablesORedActive (2), extendEnablesORedNotActive (3), extendEnablesANDedActive (4), extendEnablesANDedNotActive (5) } ACCESS read-write STATUS optional DESCRIPTION " This parameter determines if and how the extend enables will be used to modify the operation of the extend feature. extendEnablesHaveNoEffect(1) - The extend enables have no effect on the extend feature of the zone. extendEnablesORedActive(2) - If any of the extend enables are active the extend feature is active, else the extend feature is not active. extendEnablesORedNotActive(3) - If any of the extend enables are active the extend feature is not active, else the extend feature is active. extendEnablesANDedActive(4) - If all the extend enables are active the extend feature is active, else the extend feature is not active. extendEnablesANDedNotActive(5) - If all of the extend enables are active the extend feature is not active, else the extend feature is active. 1.3.6.1.4.1.1206.4.2.4.1.12.1.7" ::= { outputConditioningEntry 7 } sensorZoneOutputExtendEnables OBJECT-TYPE SYNTAX BITMAP96 ACCESS read-write STATUS optional DESCRIPTION " This bit-mapped parameter identifies which Arming Pins, Arming Input Bits, and which state for each are to be used as enables for the extend feature. If the Arming Pin inputs are DC then a low input is an ON and a high input is an OFF. If the Arming Pin inputs are AC then a low input is an OFF and a high input is an ON. byte 1 Bit 0 = Arming Pin 1 OFF, Bit 1 = Arming Pin 2 OFF, Bit 2 = Arming Pin 3 OFF, Bit 3 = Arming Pin 4 OFF, Bit 4 = Arming Pin 5 OFF, Bit 5 = Arming Pin 6 OFF, Bit 6 = Arming Pin 7 OFF, Bit 7 = Arming Pin 8 OFF, byte 2 Bit 0 = Arming Pin 9 OFF, Bit 1 = Arming Pin 10 OFF, Bit 2 = Arming Pin 11 OFF, Bit 3 = Arming Pin 12 OFF, Bit 4 = Arming Pin 13 OFF, Bit 5 = Arming Pin 14 OFF, Bit 6 = Arming Pin 15 OFF, Bit 7 = Arming Pin 16 OFF, byte 3 Bit 0 = Arming Pin 1 ON, Bit 1 = Arming Pin 2 ON, Bit 2 = Arming Pin 3 ON, Bit 3 = Arming Pin 4 ON, Bit 4 = Arming Pin 5 ON, Bit 5 = Arming Pin 6 ON, Bit 6 = Arming Pin 7 ON, Bit 7 = Arming Pin 8 ON, Byte 4 Bit 0 = Arming Pin 9 ON, Bit 1 = Arming Pin 10 ON, Bit 2 = Arming Pin 11 ON, Bit 3 = Arming Pin 12 ON, Bit 4 = Arming Pin 13 ON, Bit 5 = Arming Pin 14 ON, Bit 6 = Arming Pin 15 ON, Bit 7 = Arming Pin 16 ON, byte 5 Bit 0 = Arming Input bit 1 OFF, Bit 1 = Arming Input bit 2 OFF, Bit 2 = Arming Input bit 3 OFF, Bit 3 = Arming Input bit 4 OFF, Bit 4 = Arming Input bit 5 OFF, Bit 5 = Arming Input bit 6 OFF, Bit 6 = Arming Input bit 7 OFF, Bit 7 = Arming Input bit 8 OFF, byte 6 Bit 0 = Arming Input bit 9 OFF, Bit 1 = Arming Input bit 10 OFF, Bit 2 = Arming Input bit 11 OFF, Bit 3 = Arming Input bit 12 OFF, Bit 4 = Arming Input bit 13 OFF, Bit 5 = Arming Input bit 14 OFF, Bit 6 = Arming Input bit 15 OFF, Bit 7 = Arming Input bit 16 OFF, byte 7 Bit 0 = Arming Input bit 17 OFF, Bit 1 = Arming Input bit 18 OFF, Bit 2 = Arming Input bit 19 OFF, Bit 3 = Arming Input bit 20 OFF, Bit 4 = Arming Input bit 21 OFF, Bit 5 = Arming Input bit 22 OFF, Bit 6 = Arming Input bit 23 OFF, Bit 7 = Arming Input bit 24 OFF, byte 8 Bit 0 = Arming Input bit 25 OFF, Bit 1 = Arming Input bit 26 OFF, Bit 2 = Arming Input bit 27 OFF, Bit 3 = Arming Input bit 28 OFF, Bit 4 = Arming Input bit 29 OFF, Bit 5 = Arming Input bit 30 OFF, Bit 6 = Arming Input bit 31 OFF, Bit 7 = Arming Input bit 32 OFF, byte 9 Bit 0 = Arming Input bit 1 ON, Bit 1 = Arming Input bit 2 ON, Bit 2 = Arming Input bit 3 ON, Bit 3 = Arming Input bit 4 ON, Bit 4 = Arming Input bit 5 ON, Bit 5 = Arming Input bit 6 ON, Bit 6 = Arming Input bit 7 ON, Bit 7 = Arming Input bit 8 ON, byte 10 Bit 0 = Arming Input bit 9 ON, Bit 1 = Arming Input bit 10 ON, Bit 2 = Arming Input bit 11 ON, Bit 3 = Arming Input bit 12 ON, Bit 4 = Arming Input bit 13 ON, Bit 5 = Arming Input bit 14 ON, Bit 6 = Arming Input bit 15 ON, Bit 7 = Arming Input bit 16 ON, byte 11 Bit 0 = Arming Input bit 17 ON, Bit 1 = Arming Input bit 18 ON, Bit 2 = Arming Input bit 19 ON, Bit 3 = Arming Input bit 20 ON, Bit 4 = Arming Input bit 21 ON, Bit 5 = Arming Input bit 22 ON, Bit 6 = Arming Input bit 23 ON, Bit 7 = Arming Input bit 24 ON, byte 12 Bit 0 = Arming Input bit 25 ON, Bit 1 = Arming Input bit 26 ON, Bit 2 = Arming Input bit 27 ON, Bit 3 = Arming Input bit 28 ON, Bit 4 = Arming Input bit 29 ON, Bit 5 = Arming Input bit 30 ON, Bit 6 = Arming Input bit 31 ON, Bit 7 = Arming Input bit 32 ON, 1.3.6.1.4.1.1206.4.2.4.1.12.1.8" ::= { outputConditioningEntry 8 } sensorZoneOutputSequenced OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS optional DESCRIPTION " This parameter identifies a zone that is required to have a detection before the zone associated with this output has a detection for this output to become active. This parameter can be used to create directional detection. If the zone associated with this output has a detection before the zone identified in this parameter, this output cannot be activated and the detection ceases before it can start watching the zone identified in this parameter. If the zone identified in this parameter has a detection and remains in detection, every time the zone associated with the output has a detection, its output is activated. The intent is that the two zones are in close enough proximity that a vehicle is able to be detected by both zones and that the last zone to detect the vehicle is the one that activates its output. 1.3.6.1.4.1.1206.4.2.4.1.12.1.9" ::= { outputConditioningEntry 9 } pendingConfigurationFileName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(8..32)) ACCESS read-write STATUS optional DESCRIPTION " This identifies the name of the pending configuration file that is used by the TSS upon issuing the executePendingConfiguration command. 1.3.6.1.4.1.1206.4.2.4.1.13" ::= { tssSystemSetup 13} tssControl OBJECT IDENTIFIER ::= { tss 2 } -- node for output control data elements -- a sensor zone can be mapped to any available output -- outputs identify discrete activity states sensed within a zone -- output states should be refreshed upon change of state for each output -- 1.3.6.1.4.1.1206.4.2.4.2 maxOutputNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " Indicates the maximum number of outputs supported by this TSS. output 1.3.6.1.4.1.1206.4.2.4.2.1" ::= { tssControl 1 } outputConfigurationTable OBJECT-TYPE SYNTAX SEQUENCE OF OutputConfigurationEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Table containing configuration data elements for each TSS physical output. The number of rows in this table is equal to the maxOutputNumber data element. Table rows are set by the manufacturer, and row creation/deletion is not supported. static 1.3.6.1.4.1.1206.4.2.4.2.2" ::= { tssControl 2 } outputConfigurationEntry OBJECT-TYPE SYNTAX OutputConfigurationEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Row containing output configuration data elements. 1.3.6.1.4.1.1206.4.2.4.2.2.1" INDEX { outputNumber } ::= { outputConfigurationTable 1} OutputConfigurationEntry ::= SEQUENCE { outputNumber INTEGER, outputSensorZoneNumber INTEGER, outputFailsafeMode INTEGER, outputModeStatus BITMAP8, outputLabel OCTET STRING (SIZE (8..255)), outputArmingEnables BITMAP96, outputArmingMode INTEGER } outputNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The numerical label or number assigned to a physical output. Output number is also the row to which the outputConfigurationTable is referenced. 1.3.6.1.4.1.1206.4.2.4.2.2.1.1" ::= { outputConfigurationEntry 1 } outputSensorZoneNumber OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "The numerical label or number representing the sensor zone number that is associated with this output. A value of zero (0) indicates that no sensor zone number is associated with this output. When read, this data element returns the last value written. 1.3.6.1.4.1.1206.4.2.4.2.2.1.2" ::= { outputConfigurationEntry 2} outputFailsafeMode OBJECT-TYPE SYNTAX INTEGER { failsafeModeOn (1), failsafeModeOff (2), overrideCommandOn (3), overrideCommandOff (4), normal (5) } ACCESS read-write STATUS mandatory DESCRIPTION " Data element that allows configuration of outputs for failure override modes, as follows: failsafeModeOn(1) - The output is set to the ON state whenever there is a failure that affects the proper performance of this output; failsafeModeOff(2) - The output is set to the OFF state whenever there is a failure that affects the proper performance of this output; overrideCommandOn(3) - The output is set to the ON state, overriding the normal operational state of the output; overrideCommandOff(4) - The output is set to the OFF state, overriding the normal operational state of the output; normal(5) - The output is returned to its normal operational state. When read, this data element returns the last value written except for the value of 5. After a value of 5 is written, the value prior to the normal command is returned. 1.3.6.1.4.1.1206.4.2.4.2.2.1.3" ::= { outputConfigurationEntry 3 } outputModeStatus OBJECT-TYPE SYNTAX BITMAP8 ACCESS read-only STATUS mandatory DESCRIPTION " A bit-mapped value as defined below for reading the status of failure override modes, as follows: bit 7 0 = OFF, 1 = ON For Failsafe Mode Status ON indicates the Failsafe Mode is ON, meaning that the output assumes an ON state whenever there is a failure that in any way affects the proper performance of this output and Failsafe Mode Status OFF indicates the status of the Failsafe Mode is OFF, meaning that the output assumes an OFF state whenever there is a failure that in any way affects the proper performance of this output (MSB); bit 6 0 = OFF, 1 = ON For Override Command Status ON indicates the presence of an Override to the normal operational state of the output to ON and Override Command Status Off indicates the presence of an Override to the normal operational state of the output to OFF; bit 5..0 Reserved (bit 0 = LSB). 1.3.6.1.4.1.1206.4.2.4.2.2.1.4" ::= { outputConfigurationEntry 4 } outputLabel OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8..255)) ACCESS read-write STATUS optional DESCRIPTION " Text string to describe the TSS output. A maximum string length of less than 255 may be supported. 1.3.6.1.4.1.1206.4.2.4.2.2.1.5" ::= { outputConfigurationEntry 5 } outputArmingEnables OBJECT-TYPE SYNTAX BITMAP96 ACCESS read-write STATUS optional DESCRIPTION " Consists of up to 16 physical Arming Pins to the TSS and up to 32 bits of external arming bits which can be controlled through this protocol. The Arming Pins have historically been connected to the phase greens but can be used for any purpose. It is envisioned that the phase green information could be sent through Arming Input Bits using the protocol and eliminate the need for additional wiring. If the Arming Pin inputs are DC then a low input is an ON and a high input is an OFF. If the Arming Pin inputs are AC then a low input is an OFF and a high input is an ON. byte 1 Bit 0 = Arming Pin 1 OFF, Bit 1 = Arming Pin 2 OFF, Bit 2 = Arming Pin 3 OFF, Bit 3 = Arming Pin 4 OFF, Bit 4 = Arming Pin 5 OFF, Bit 5 = Arming Pin 6 OFF, Bit 6 = Arming Pin 7 OFF, Bit 7 = Arming Pin 8 OFF, byte 2 Bit 0 = Arming Pin 9 OFF, Bit 1 = Arming Pin 10 OFF, Bit 2 = Arming Pin 11 OFF, Bit 3 = Arming Pin 12 OFF, Bit 4 = Arming Pin 13 OFF, Bit 5 = Arming Pin 14 OFF, Bit 6 = Arming Pin 15 OFF, Bit 7 = Arming Pin 16 OFF, byte 3 Bit 0 = Arming Pin 1 ON, Bit 1 = Arming Pin 2 ON, Bit 2 = Arming Pin 3 ON, Bit 3 = Arming Pin 4 ON, Bit 4 = Arming Pin 5 ON, Bit 5 = Arming Pin 6 ON, Bit 6 = Arming Pin 7 ON, Bit 7 = Arming Pin 8 ON, byte 4 Bit 0 = Arming Pin 9 ON, Bit 1 = Arming Pin 10 ON, Bit 2 = Arming Pin 11 ON, Bit 3 = Arming Pin 12 ON, Bit 4 = Arming Pin 13 ON, Bit 5 = Arming Pin 14 ON, Bit 6 = Arming Pin 15 ON, Bit 7 = Arming Pin 16 ON, byte 5 Bit 0 = Arming Input bit 1 OFF, Bit 1 = Arming Input bit 2 OFF, Bit 2 = Arming Input bit 3 OFF, Bit 3 = Arming Input bit 4 OFF, Bit 4 = Arming Input bit 5 OFF, Bit 5 = Arming Input bit 6 OFF, Bit 6 = Arming Input bit 7 OFF, Bit 7 = Arming Input bit 8 OFF, byte 6 Bit 0 = Arming Input bit 9 OFF, Bit 1 = Arming Input bit 10 OFF, Bit 2 = Arming Input bit 11 OFF, Bit 3 = Arming Input bit 12 OFF, Bit 4 = Arming Input bit 13 OFF, Bit 5 = Arming Input bit 14 OFF, Bit 6 = Arming Input bit 15 OFF, Bit 7 = Arming Input bit 16 OFF, byte 7 Bit 0 = Arming Input bit 17 OFF, Bit 1 = Arming Input bit 18 OFF, Bit 2 = Arming Input bit 19 OFF, Bit 3 = Arming Input bit 20 OFF, Bit 4 = Arming Input bit 21 OFF, Bit 5 = Arming Input bit 22 OFF, Bit 6 = Arming Input bit 23 OFF, Bit 7 = Arming Input bit 24 OFF, byte 8 Bit 0 = Arming Input bit 25 OFF, Bit 1 = Arming Input bit 26 OFF, Bit 2 = Arming Input bit 27 OFF, Bit 3 = Arming Input bit 28 OFF, Bit 4 = Arming Input bit 29 OFF, Bit 5 = Arming Input bit 30 OFF, Bit 6 = Arming Input bit 31 OFF, Bit 7 = Arming Input bit 32 OFF, byte 9 Bit 0 = Arming Input bit 1 ON, Bit 1 = Arming Input bit 2 ON, Bit 2 = Arming Input bit 3 ON, Bit 3 = Arming Input bit 4 ON, Bit 4 = Arming Input bit 5 ON, Bit 5 = Arming Input bit 6 ON, Bit 6 = Arming Input bit 7 ON, Bit 7 = Arming Input bit 8 ON, byte 10 Bit 0 = Arming Input bit 9 ON, Bit 1 = Arming Input bit 10 ON, Bit 2 = Arming Input bit 11 ON, Bit 3 = Arming Input bit 12 ON, Bit 4 = Arming Input bit 13 ON, Bit 5 = Arming Input bit 14 ON, Bit 6 = Arming Input bit 15 ON, Bit 7 = Arming Input bit 16 ON, byte 11 Bit 0 = Arming Input bit 17 ON, Bit 1 = Arming Input bit 18 ON, Bit 2 = Arming Input bit 19 ON, Bit 3 = Arming Input bit 20 ON, Bit 4 = Arming Input bit 21 ON, Bit 5 = Arming Input bit 22 ON, Bit 6 = Arming Input bit 23 ON, Bit 7 = Arming Input bit 24 ON, byte 12 Bit 0 = Arming Input bit 25 ON, Bit 1 = Arming Input bit 26 ON, Bit 2 = Arming Input bit 27 ON, Bit 3 = Arming Input bit 28 ON, Bit 4 = Arming Input bit 29 ON, Bit 5 = Arming Input bit 30 ON, Bit 6 = Arming Input bit 31 ON, Bit 7 = Arming Input bit 32 ON. 1.3.6.1.4.1.1206.4.2.4.2.2.1.6" ::= { outputConfigurationEntry 6 } outputArmingMode OBJECT-TYPE SYNTAX INTEGER { armingEnablesHaveNoEffect (1), normOffArmingEnablesORedZone (2), normOnArmingEnablesORedZone (3), normZoneArmingEnablesORedOff (4), normZoneArmingEnablesORedOn (5), normOffArmingEnablesANDedZone (6), normOnArmingEnablesANDedZone (7), normZoneArmingEnablesANDedOff (8), normZoneArmingEnablesANDedOn (9)} ACCESS read-write STATUS mandatory DESCRIPTION " This parameter determines if and how the Arming Enables are used to modify the operation of this output. armingEnablesHaveNoEffect(1) - The Arming Enables have no effect on the output of the zone. normOffArmingEnablesORedZone(2) - The zone output is OFF when none of the Arming Enables are active, and the actual zone state when any of the Arming Enables are active. normOnArmingEnablesORedZone(3) - The zone output is ON when none of the Arming Enables are active, and the actual zone state when any of the Arming Enables are active. normZoneArmingEnablesORedOff(4) - The zone output is the actual zone state when none of the Arming Enables are active, and OFF when any of the Arming Enables are active. normZoneArmingEnablesORedOn(5) - The zone output is the actual zone state when none of the Arming Enables are active, and ON when any of the Arming Enables are active. normOffArmingEnablesANDedZone(6) - The zone output is OFF when any of the Arming Enables are not active, and the actual zone state when all of the Arming Enables are active. normOnArmingEnablesANDedZone(7) - The zone output is ON when any of the Arming Enables are not active, and the actual zone state when all of the Arming Enables or active. normZoneArmingEnablesANDedOff(8) - The zone output is the actual zone state when any of the Arming Enables are not active, and OFF when all of the Arming Enables are active. normZoneArmingEnablesANDedOn(9) - The zone output is the actual zone state when any of the Arming Enables are not active, and ON when all of the Arming Enables are active. 1.3.6.1.4.1.1206.4.2.4.2.2.1.7" ::= { outputConfigurationEntry 7 } maxOutputGroups OBJECT-TYPE SYNTAX INTEGER (1..32) ACCESS read-only STATUS mandatory DESCRIPTION " Indicates the maximum number of output groups supported by this TSS. output 1.3.6.1.4.1.1206.4.2.4.2.3" ::= { tssControl 3 } outputGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF OutputGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table containing input and output states for groups of eight outputs. Each output group represents a multiple of eight (8) sequentially numbered outputs. Output Group 1 consists of Outputs 1 to 8, Output Group 2 consists of Outputs 9 to 16, etc. The number of rows in this table is equal to the maxOutputGroups data element. Table rows are set by the manufacturer, and row creation/deletion is not supported. static 1.3.6.1.4.1.1206.4.2.4.2.4" ::= { tssControl 4 } outputGroupEntry OBJECT-TYPE SYNTAX OutputGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Table for output states, in groups of eight outputs. Each output group represents a multiple of eight (8) sequentially numbered outputs. Example: Output Group 1 consists of Outputs 1 to 8, Output Group 2 consists of Outputs 9 to 16, etc. 1.3.6.1.4.1.1206.4.2.4.2.4.1" INDEX { outputGroupNumber } ::= { outputGroupTable 1 } OutputGroupEntry ::= SEQUENCE { outputGroupNumber INTEGER, outputGroupOutputState BITMAP8 } outputGroupNumber OBJECT-TYPE SYNTAX INTEGER (1..32) ACCESS read-only STATUS mandatory DESCRIPTION " Number of the output group, in groups of eight outputs. Each output group represents a multiple of eight (8) sequentially numbered outputs. Output Group 1 consists of Outputs 1 to 8, Output Group 2 consists of Outputs 9 to 16, etc. output 1.3.6.1.4.1.1206.4.2.4.2.4.1.1" ::= { outputGroupEntry 1 } outputGroupOutputState OBJECT-TYPE SYNTAX BITMAP8 ACCESS read-only STATUS mandatory DESCRIPTION " Each bit represents the output state for each output within each output group. Each output group represents a multiple of eight (8) sequentially numbered outputs. Example: Output Group 1 consists of Outputs 1 to 8, Output Group 2 consists of Outputs 9 to 16, etc. Bit 0 represents output 1, bit 1 represents output 2, etc., as follows: bit 7 0 = OFF, 1 = ON For output 8 within the group (MSB), bit 6 0 = OFF, 1 = ON For output 7 within the group, bit 5 0 = OFF, 1 = ON For output 6 within the group, bit 4 0 = OFF, 1 = ON For output 5 within the group, bit 3 0 = OFF, 1 = ON For output 4 within the group, bit 2 0 = OFF, 1 = ON For output 3 within the group, bit 1 0 = OFF, 1 = ON For output 2 within the group, bit 0 0 = OFF, 1 = ON For output 1 within the group (LSB). 1.3.6.1.4.1.1206.4.2.4.2.4.1.2" ::= { outputGroupEntry 2 } tssDataCollection OBJECT IDENTIFIER ::= { tss 3 } -- node for data collection elements -- 1.3.6.1.4.1.1206.4.2.4.3 -- This object has been deprecated. See Annex D for more information. dataCollectionTable OBJECT-TYPE SYNTAX SEQUENCE OF DataCollectionEntry ACCESS not-accessible STATUS deprecated DESCRIPTION " Table containing the most recently completed sample period data. The number of rows in this table is equal to the maxSensorZones data element. Table rows are set by the manufacturer, and row creation/deletion is not supported. If this object is supported, it reports the same data that is returned using the new object sampleDataTable with a sampleZoneClass of one and a sampleEntryNum of two. static 1.3.6.1.4.1.1206.4.2.4.3.1" ::= { tssDataCollection 1 } dataCollectionEntry OBJECT-TYPE SYNTAX DataCollectionEntry ACCESS not-accessible STATUS deprecated DESCRIPTION " Table for data collection parameters. 1.3.6.1.4.1.1206.4.2.4.3.1.1" INDEX { sensorZoneNumber } ::= { dataCollectionTable 1 } DataCollectionEntry ::= SEQUENCE { endTime Counter, volumeData INTEGER, percentOccupancy INTEGER, speedData INTEGER, zoneStatus INTEGER } -- This object has been deprecated. See Annex D for more information. endTime OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS deprecated DESCRIPTION " Indicates the time at which the data collection period ended for the data contained in this row, the most recently completed sample period. If the clockAvailable data element indicates the presence of a clock, this time shall be expressed in local time as expressed in the controllerLocalTime data element (see NTCIP 1201 v03); otherwise, this time shall be expressed in the number of seconds since the most recent TSS initialization. If this object is supported, it must report the same data that will be returned using the new object, sampleDataTable.sampleEndTime, with a sampleZoneClass of one and a sampleEntryNum of two. second 1.3.6.1.4.1.1206.4.2.4.3.1.1.1" ::= { dataCollectionEntry 1 } --This object has been deprecated. See Annex D for more information. volumeData OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS deprecated DESCRIPTION " Counts per sample period, for the most recently completed sample period. Counts are expressed as an integer value in the volumeData data element. The value of 65535 shall be returned to represent a missing value. A missing value is reported when the zoneStatus is anything other than OK for the entire sampling period. If this object is supported, it is required to report the same data that is returned using the new object, sampleDataTable.sampleVolumeData, with a sampleZoneClass of one and a sampleEntryNum of two. count 1.3.6.1.4.1.1206.4.2.4.3.1.1.2" ::= { dataCollectionEntry 2 } -- This object has been deprecated. See Annex D for more information. percentOccupancy OBJECT-TYPE SYNTAX INTEGER (0..1000 | 65535) ACCESS read-only STATUS deprecated DESCRIPTION " Percent occupancy over the sample period for the most recently completed sample period. Occupancy is expressed in tenths of a percent, from 0 to 100.0 percent, in the percentOccupancy data element. The value of 65535 shall be returned to represent an invalid or missing value. A missing value is reported when the zoneStatus is anything other than OK for the entire sampling period. Values 1001 through 65534 are reserved for future use. If this object is supported, it must report the same data that will be returned using the new object, sampleDataTable.samplePercentOccupancy, with a sampleZoneClass of one and a sampleEntryNum of two. percent 1.3.6.1.4.1.1206.4.2.4.3.1.1.3" ::= { dataCollectionEntry 3 } -- This object has been deprecated. See Annex D for more information. speedData OBJECT-TYPE SYNTAX INTEGER (0..2550 | 65535) ACCESS read-only STATUS deprecated DESCRIPTION " Arithmetic mean of speeds collected over the sample period with units of 1/10ths of km/h, for the most recently completed sample period. For a volume of zero during the sample period, the value of 65535 shall be returned to represent an invalid or missing value. A missing value is reported when the zoneStatus returned indicates no other status values apply for the entire sampling period. Values 2551 through 65534 are reserved for future use. If this object is supported, it is required to report the same data that is returned using the new object, sampleDataTable.sampleSpeedData, with a sampleZoneClass of one and a sampleEntryNum of two. tenths of km/h 1.3.6.1.4.1.1206.4.2.4.3.1.1.4" -- conversion to English units must be done within the application ::= { dataCollectionEntry 4 } -- This object has been deprecated. See Annex D for more information. zoneStatus OBJECT-TYPE SYNTAX INTEGER { other (1), oK (2), initializing (3), noActivity (4), maxPresence (5), configurationError (6), erraticCounts (7), disabled (8), overrideActive (9), sensorFailure (10) } ACCESS read-only STATUS deprecated DESCRIPTION " Detailed status returned as result of diagnostics, as follows: Value Meaning Other - Indicates an error has occurred within the TSS for which there is no defined definition within this data element, oK - Indicates no other status values apply, initializing - Indicates an initialization or diagnostics procedure is in-progress, noActivity - Indicates no activity condition, maxPresence - Indicates max presence condition, configurationError - Indicates an error within the TSS configuration setup, erraticCounts - Indicates erratic counts, disabled - Indicates that the zone is disabled. overrideActive - Indicates an override is active. sensorFailure - Indicates a sensing element failure. If a condition occurs during the sample period, then that state remains for the duration of that sample period. If multiple conditions occur during a sample period, the last reported condition, other than OK, is retained. If this object is supported, it is required to report the same data that is returned using the new object, sampleDataTable.sampleZoneStatus, with a sampleZoneClass of one and a sampleEntryNum of two. 1.3.6.1.4.1.1206.4.2.4.3.1.1.5" ::= { dataCollectionEntry 5 } -- This object has been deprecated. See Annex D for more information. dataBufferTable OBJECT-TYPE SYNTAX SEQUENCE OF DataBufferEntry ACCESS not-accessible STATUS deprecated DESCRIPTION " Table containing the second most recently completed previous sample period data, which value is specified by the value of the sensorZoneSamplePeriod data element. The previous period data overwrites the data for the sample period data immediately preceding the previous sample period. The number of rows in this table is equal to the maxSensorZones data element. Table rows are set by the manufacturer, and row creation/deletion is not supported. If this object is supported, it is required to report the same data that is returned using the new object sampleDataTable with a sampleZoneClass of one and a sampleEntryNum of three. static 1.3.6.1.4.1.1206.4.2.4.3.2" ::= { tssDataCollection 2 } dataBufferEntry OBJECT-TYPE SYNTAX DataBufferEntry ACCESS not-accessible STATUS deprecated DESCRIPTION " Table containing the data collection parameters for the second most recently completed previous sample period. 1.3.6.1.4.1.1206.4.2.4.3.2.1" INDEX { sensorZoneNumber } ::= { dataBufferTable 1 } DataBufferEntry ::= SEQUENCE { endTimeBuffer Counter, volumeDataBuffer INTEGER, percentOccupancyBuffer INTEGER, speedDataBuffer INTEGER, zoneStatusBuffer INTEGER } -- This object has been deprecated. See Annex D for more information. endTimeBuffer OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS deprecated DESCRIPTION " Indicates the time at which the data collection period ended for the data contained in this row, the second most recently completed previous sample period. If the clockAvailable data element indicates the presence of a clock, this time shall be expressed in local time as expressed in the controllerLocalTime data element (see NTCIP 1201 v03); otherwise, this time shall be expressed in the number of seconds since the most recent TSS initialization. If this object is supported, it is required to report the same data that is returned using the new object, sampleDataEntry.sampleEndTime, with a sampleZoneClass of one and a sampleEntryNum of three. second 1.3.6.1.4.1.1206.4.2.4.3.2.1.1" ::= { dataBufferEntry 1 } -- This object has been deprecated. See Annex D for more information. volumeDataBuffer OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS deprecated DESCRIPTION " Counts per sample period, for the second most recently completed previous sample period. Counts are expressed as an integer value in the volumeData data element. The value of 65535 shall be returned to represent a missing value. A missing value is reported when the zoneStatusBuffer returned indicates no other status values apply for the entire sampling period. If this object is supported, it is required to report the same data that is returned using the new object, sampleDataEntry.sampleVolumeData, with a sampleZoneClass of one and a sampleEntryNum of three. count 1.3.6.1.4.1.1206.4.2.4.3.2.1.2" ::= { dataBufferEntry 2 } -- This object has been deprecated. See Annex D for more information. percentOccupancyBuffer OBJECT-TYPE SYNTAX INTEGER (0..1000 | 65535) ACCESS read-only STATUS deprecated DESCRIPTION " Percent occupancy over the sample period for the second most recently completed previous sample period. Occupancy is expressed in tenths of a percent, from 0 to 100.0 percent, in the percentOccupancy data element. The value of 65535 shall be returned to represent an invalid or missing value. A missing value is reported when the zoneStatusBuffer is anything other than OK for the entire sampling period. Values 1001 through 65534 are reserved for future use. If this object is supported, it is required to report the same data that is returned using the new object, sampleDataEntry.samplePercentOccupancy, with a sampleZoneClass of one and a sampleEntryNum of three. percent 1.3.6.1.4.1.1206.4.2.4.3.2.1.3" ::= { dataBufferEntry 3 } -- This object has been deprecated. See Annex D for more information. speedDataBuffer OBJECT-TYPE SYNTAX INTEGER (0..2550 | 65535) ACCESS read-only STATUS deprecated DESCRIPTION " Arithmetic mean of speeds collected over the sample period, with units of 1/10ths of km/hr, for the second most recently completed previous sample period. For a volume of zero during the sample period, the value of 65535 shall be returned to represent an invalid or missing value. A missing value is reported when the zoneStatusBuffer is anything other than OK for the entire sampling period. Values 2551 through 65534 are reserved for future use. If this object is supported, it is required to report the same data that is returned using the new object, sampleDataEntry.sampleSpeedData, with a sampleZoneClass of one and a sampleEntryNum of three. tenths of km/hr 1.3.6.1.4.1.1206.4.2.4.3.2.1.4" -- conversions to English units from SI are required to be done within the applications ::= { dataBufferEntry 4 } -- This object has been deprecated. See Annex D for more information. zoneStatusBuffer OBJECT-TYPE SYNTAX INTEGER { other (1), oK (2), initializing (3), noActivity (4), maxPresence (5), configurationError (6), erraticCounts (7), disabled (8), overrideActive (9), sensorFailure (10) } ACCESS read-only STATUS deprecated DESCRIPTION "Detailed status returned as result of diagnostics, for the previous sample period, as follows: Value Meaning Other - Indicates an error has occurred within the TSS for which there is no defined definition within this data element, oK - Indicates no other status values apply, initializing - Indicates an initialization or diagnostics procedure is in-progress, noActivity - Indicates no activity condition, maxPresence - Indicates max presence condition, configurationError - Indicates an error within the TSS configuration setup, erraticCounts - Indicates erratic counts, disabled - Indicates that the zone is disabled, overrideActive - Indicates an override is active, sensorFailure - Indicates a sensing element failure. If a condition occurs during the sample period, then that state remains for the duration of that sample period. If multiple conditions occur during a sample period, the last reported condition, other than OK, is retained. If this object is supported, it is required to report the same data that is returned using the new object, sampleDataEntry.sampleZoneStatus, with a sampleZoneClass of one and a sampleEntryNum of three. 1.3.6.1.4.1.1206.4.2.4.3.2.1.5" ::= { dataBufferEntry 5 } zoneSequenceTable OBJECT-TYPE SYNTAX SEQUENCE OF ZoneSequenceTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Table containing entries for the number of historical data entries and the number of classes available for retrieval for each zone. The maxSensorZones defines the number of entries in this table. For each zone, retrieve the numSampleDataEntries available and the sensorZoneClass for those historical data entries, then retrieve the appropriate data samples from the sampleDataTable. static 1.3.6.1.4.1.1206.4.2.4.3.3" ::= { tssDataCollection 3 } zoneSequenceTableEntry OBJECT-TYPE SYNTAX ZoneSequenceTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Table containing the number of historical data entries and the number of classes within each historical data entry for each zone. The maxSensorZones table defines the number of entries in this table. 1.3.6.1.4.1.1206.4.2.4.3.3.1" INDEX { sensorZoneNumber } ::= { zoneSequenceTable 1 } ZoneSequenceTableEntry::= SEQUENCE { numSampleDataEntries INTEGER, numSensorZoneClass INTEGER } numSampleDataEntries OBJECT-TYPE SYNTAX INTEGER (1..5) ACCESS read-only STATUS mandatory DESCRIPTION " The number of historical data entries in the sampleDataTable for a particular zone. count 1.3.6.1.4.1.1206.4.2.4.3.3.1.1" ::= { zoneSequenceTableEntry 1 } numSensorZoneClass OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " This is the number of classes currently supported for each historical data entry for a particular zone. 1.3.6.1.4.1.1206.4.2.4.3.3.1.2" ::= { zoneSequenceTableEntry 2 } sampleDataTable OBJECT-TYPE SYNTAX SEQUENCE OF SampleDataEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Table containing the historical sample period data. The number of rows in this table is equal to the maxSensorZones data element multiplied by the maxSampleDataEntries data element. Table rows are set by the manufacturer, and row creation/deletion is not supported. To retrieve all historical data entries for a zone, the last (oldest) entry should be retrieved by using numSampleDataEntries and retrieving class one (1) through numSensorZoneClass first. Class 1 is an aggregation of the data from all of the other classes (if any exist). All of the class data for a particular numSampleDataEntries has the same sequenceNumber. Once these entries are retrieved, the other entries sequence numbers denote the correct order of the samples. Sequence number is used rather than end date as the system clock may have been reset between data samples. static 1.3.6.1.4.1.1206.4.2.4.3.4" ::= { tssDataCollection 4 } sampleDataEntry OBJECT-TYPE SYNTAX SampleDataEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Table for data collection parameters. 1.3.6.1.4.1.1206.4.2.4.3.4.1" INDEX { sensorZoneNumber, sampleEntryNum, sampleZoneClass } ::= { sampleDataTable 1 } SampleDataEntry ::= SEQUENCE { sampleEntryNum INTEGER, sampleZoneClass INTEGER, sampleEndTime Counter, sampleVolumeData INTEGER, samplePercentOccupancy INTEGER, sampleSpeedData INTEGER, sampleZoneStatus INTEGER, sampleSequenceNumber INTEGER } sampleEntryNum OBJECT-TYPE SYNTAX INTEGER (1..5) ACCESS read-only STATUS mandatory DESCRIPTION " This identifies which historical sampling period that data is being requested from. 1 being the sampling period currently in-progress. 2 being the most recently completed sampling period. count 1.3.6.1.4.1.1206.4.2.4.3.4.1.1" ::= { sampleDataEntry 1 } sampleZoneClass OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " This identifies the class of the sensor zone from which historical sampling period data is being requested. Class 1 retrieves an aggregate of the data from all classes within the requested historical data entry. 1.3.6.1.4.1.1206.4.2.4.3.4.1.2" ::= { sampleDataEntry 2 } sampleEndTime OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " Indicates the time at which the data collection period ended for the data contained in this row. If the clockAvailable data element indicates the presence of a clock, this time shall be expressed in local time as expressed in the controllerLocalTime data element (see NTCIP 1201 v03); otherwise, this time shall be expressed in the number of seconds since the most recent TSS initialization. seconds 1.3.6.1.4.1.1206.4.2.4.3.4.1.3" ::= { sampleDataEntry 3 } sampleVolumeData OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION " Counts per sample period. Counts are expressed as an integer value in the sampleVolumeData data element. For a virtual zone (one created using any AND Boolean functions), volume is the number of times that the output for the zone was activated. For a virtual zone (one created using only OR Boolean functions), volume is the additive total of the volumes of all of the zones that make up the virtual zone. The value of 65535 shall be returned to represent a missing value. A missing value is reported when the zoneStatus is anything other than OK for the entire sampling period. count 1.3.6.1.4.1.1206.4.2.4.3.4.1.4" ::= { sampleDataEntry 4 } samplePercentOccupancy OBJECT-TYPE SYNTAX INTEGER (0..1000 | 65535) ACCESS read-only STATUS mandatory DESCRIPTION " Percent occupancy over the sample period. Occupancy is expressed in tenths of a percent, from 0 to 100.0 percent, in the samplePercentOccupancy data element. For a virtual zone (one created using AND and/or OR Boolean functions), the percent of time that the output for the zone was activated shall be returned. The value of 65535 shall be returned to represent an invalid or missing value. A missing value is reported when the zoneStatus is anything other than OK for the entire sampling period. Values 1001 through 65534 are reserved for future use. percent 1.3.6.1.4.1.1206.4.2.4.3.4.1.5" ::= { sampleDataEntry 5 } sampleSpeedData OBJECT-TYPE SYNTAX INTEGER (0..2550 | 65535) ACCESS read-only STATUS mandatory DESCRIPTION " Arithmetic mean of speeds collected over the sample period with units of 1/10ths of km/h. For a virtual zone (one created using AND and/or OR Boolean functions), the value of 65535 shall be returned as it is not straight forward to calculate speed from logically combined zones. For a volume of zero during the sample period, the value of 65535 shall be returned to represent an invalid or missing value. A missing value is reported when the zoneStatus returned indicates no other status values apply for the entire sampling period. Values 2551 through 65534 are reserved for future use. tenths of km/h 1.3.6.1.4.1.1206.4.2.4.3.4.1.6" -- conversion to English units must be done within the application ::= { sampleDataEntry 6 } sampleZoneStatus OBJECT-TYPE SYNTAX INTEGER { other (1), oK (2), initializing (3), noActivity (4), maxPresence (5), configurationError (6), erraticCounts (7), disabled (8), overrideActive (9), sensorFailure (10), inputDataIntegrity (11), poorContrast (12), detectionAutoSuspended (13), pairedZoneFault (14) } ACCESS read-only STATUS mandatory DESCRIPTION " Detailed status returned as result of diagnostics, as follows: Value Meaning other(1) - Indicates an error has occurred within the TSS for which there is no defined definition within this data element. oK(2) - Indicates no other status values apply. initializing(3) - Indicates an initialization or diagnostics procedure is in-progress. noActivity(4) - Indicates no activity condition. maxPresence(5) - Indicates max presence condition. configurationError(6) - Indicates an error within the TSS configuration setup. erraticCounts(7 )- Indicates erratic counts. disabled(8) - Indicates that the zone is disabled. overrideActive(9) - Indicates an override is active. sensorFailure(10) - Indicates a sensing element failure. inputDataIntegrity(11) - indicates input values are not sufficient to determine detector data accurately (e.g., bad communications, invalid video for machine vision). poorContrast(12) - Indicates insufficient contrast error condition. detectionAutoSuspended(13) - Indicates that the detection zone was automatically disabled by the TSS (e.g., camera is on a PTZ and was moved). pairedZoneFault(14) - Indicates that there was no problem with this zone, but a zone that it is paired with had a fault. This may affect the accuracy of data reported by this zone. If a condition occurs during the sample period, then that state remains for the duration of that sample period. If multiple conditions occur during a sample period, the last reported condition, other than OK, is retained. 1.3.6.1.4.1.1206.4.2.4.3.4.1.7" ::= { sampleDataEntry 7 } sampleSequenceNumber OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION " The data samples sequence number, used to determine the appropriate order of samples for a particular zone. All data from the same sampling period have the same historical sequence number (all classes from the same period have the same sequence number). count 1.3.6.1.4.1.1206.4.2.4.3.4.1.8" ::= { sampleDataEntry 8 } zoneClassTable OBJECT-TYPE SYNTAX SEQUENCE OF ZoneClassTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " This is a table that allows the TSS to return a class label for a particular class of a particular zone. These are most likely set by the manufacturer; however the manufacturer may allow the user to modify these through means outside of this protocol. static 1.3.6.1.4.1.1206.4.2.4.3.5" ::= { tssDataCollection 5 } zoneClassTableEntry OBJECT-TYPE SYNTAX ZoneClassTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Table containing entries for the class labels for each zone. 1.3.6.1.4.1.1206.4.2.4.3.5.1" INDEX { sensorZoneNumber, sampleZoneClass } ::= { zoneClassTable 1 } ZoneClassTableEntry ::= SEQUENCE { zoneClassLabel OCTET STRING } zoneClassLabel OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..255)) ACCESS read-only STATUS mandatory DESCRIPTION " The label assigned to a particular class number to aid in identifying the data contained within the class. 1.3.6.1.4.1.1206.4.2.4.3.5.1.1" ::= { zoneClassTableEntry 1 } tssInductiveLoop OBJECT IDENTIFIER ::= { tss 4 } -- This node contains the configuration objects specific to inductive loop -- detectors. -- These objects set up physical parameters on the detector that are -- controlled on a per output basis. -- These objects are only valid for the zones that map directly to an output -- on the detector. -- Zone 1 maps to output 1 and Zone 2 maps to output 2 on a two-channel -- sensor unit and Zone 3 maps to output 3, and Zone 4 maps to output 4 on a -- four-channel sensor unit. -- For inductive loop detectors, the term "channel" is often used to refer to -- an "output". -- 1.3.6.1.4.1.1206.4.2.4.4 loopSensorSetupTable OBJECT-TYPE SYNTAX SEQUENCE OF LoopSensorSetupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " This table contains inductive loop detector sensor zone parameters. The number of rows in this table does not exceed maxSensorZones. This table contains the configuration objects specific to inductive loop detectors. These objects set up physical parameters on the detector that are controlled on a per output basis. A zone maps directly to an output on an inductive loop detector - Zone 1 maps to output 1, Zone 2 maps to output 2, and, on a four-channel sensor unit, Zone 3 maps to output 3 and Zone 4 maps to output 4. Virtual zones may be supported once all physical outputs have had sensor zones mapped to them. Table rows are set by the manufacturer, and row creation/deletion is not supported. static 1.3.6.1.4.1.1206.4.2.4.4.1" ::= { tssInductiveLoop 1 } loopSensorSetupEntry OBJECT-TYPE SYNTAX LoopSensorSetupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Row in table that contains inductive loop detector sensor zone parameters. The number of rows in this table does not exceed maxSensorZones or maxOutputNumber, whichever is greater. Table rows are set by the manufacturer, and row creation/deletion is not supported. 1.3.6.1.4.1.1206.4.2.4.4.1.1" INDEX { sensorZoneNumber } ::= { loopSensorSetupTable 1 } LoopSensorSetupEntry ::= SEQUENCE { zoneSensitivityMode INTEGER, zoneSensitivity OCTET STRING, zoneFrequencyRange OCTET STRING, sensorZoneLoopLayout INTEGER } zoneSensitivityMode OBJECT-TYPE SYNTAX INTEGER { deltaL (1), deltaLOverSqrtL (2), deltaLOverL (3) } ACCESS read-only STATUS mandatory DESCRIPTION " Sensitivity mode in use (3=L/L, 2=L/L, 1=L). This is a characteristic of the loop detector being used. 1.3.6.1.4.1.1206.4.2.4.4.1.1.1" ::= { loopSensorSetupEntry 1 } zoneSensitivity OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2)) ACCESS read-write STATUS mandatory DESCRIPTION " This bit-mapped object allows the setting and reading of the sensitivity for the zone as follows: bit 3,bit 2,bit1,bit 0 Meaning 0000 Zone OFF (Disabled) (LSB) 0001 Detect L = 512 nanoHenries or L/L = 0.64% 0010 Detect L = 256 nanoHhenries or L/L = 0.32% 0011 Detect L = 128 nanoHenries or L/L = 0.16% 0100 Detect L = 64 nanoHenries or L/L = 0.08% 0101 Detect L = 32 nanoHenries or L/L = 0.04% 0110 Detect L = 16 nanoHenries or L/L = 0.02% 0111 Detect L = 8 nanoHenries or L/L = 0.01% or, if bit 15=1 Detect L = 0 to 32,767 nanoHenries or L/L = 0 to 32.767% (MSB) These sensitivity definitions are equal with a loop inductance of 80 microHenries. A detector need not support all of these settings. However, the sensitivities it does support are required to conform with these definitions, e.g. a sensitivity setting of 3 is always 128 nanoHenries or 0.16% with an 80 microhenry loop. If bit 15=1, bit 0 – bit 14 contain the sensitivity in nanoHenries or one-thousands of a percent, e.g. 3650 is 3.650%. A value of 65535 shall be returned to represent invalid data or not a physical zone. Values of 8 through 32767 are reserved. 1.3.6.1.4.1.1206.4.2.4.4.1.1.2" ::= { loopSensorSetupEntry 2 } zoneFrequencyRange OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-write STATUS mandatory DESCRIPTION " Allows the setting and reading of the frequency range as follows: bit 2, bit 1, bit 0 Meaning 000 Frequency Range 0 (lowest frequency) (LSB) 001 Frequency Range 1 010 Frequency Range 2 011 Frequency Range 3 (highest frequency for 4 freq. unit) (MSB) As the frequency number increases the operation frequency shall increase. The loop frequency at the lowest frequency setting shall be less than 88% of the loop frequency at the highest frequency setting. Bit 3 can be used to allow a unit to support 8 frequency ranges instead of the four. A value of 255 shall be returned to represent invalid data or not a physical zone. Values of 8 through 254 are reserved. 1.3.6.1.4.1.1206.4.2.4.4.1.1.3" ::= { loopSensorSetupEntry 3 } sensorZoneLoopLayout OBJECT-TYPE SYNTAX INTEGER { other (1), oneSixBySixLoopOneLane (2), twoSixBySixLoopsOneLane (3), threeSixBySixLoopsOneLane (4), fourSixBySixLoopsOneLane (5), oneLongLoopOneLane (6), oneSixBySixLoopMultipleLanes (7) } ACCESS read-write STATUS optional DESCRIPTION " The zone configuration provides for standardized sensor loop layouts typically used in roadway applications. other(1) - Used for special loop configurations and layouts. oneSixBySixLoopOneLane(2) - Used when there in one six-foot by six- foot loop in one travel lane. twoSixBySixLoopsOneLane(3) - Used when there are two six-foot by six- foot loops in one travel lane. threeSixBySixLoopsOneLane(4) - Used when there are three six-foot by six-foot loops in one travel lane. fourSixBySixLoopsOneLane(5) - Used when there are four six-foot by six- foot loops in one travel lane. oneLongLoopOneLane(6) - Used when there is one loop in one travel lane that exceeds six-feet in length. oneSixBySixLoopMultipleLanes(7) - Used when there is one six-foot by six-foot loop in each of more than one travel lane. 1.3.6.1.4.1.1206.4.2.4.4.1.1.4" ::= { loopSensorSetupEntry 4 } --This object has been deprecated. See Annex D for more information. loopOutputConditioningTable OBJECT-TYPE SYNTAX SEQUENCE OF LoopOutputConditioningEntry ACCESS not-accessible STATUS deprecated DESCRIPTION " Each table row contains objects for configuring inductive loop detector sensor zone outputs. The number of rows in this table does not exceed maxSensorZones. Table rows are set by the manufacturer, and row creation/deletion is not supported. If this object is supported, it must use the same data that will be used by the new object outputConditioningTable. static 1.3.6.1.4.1.1206.4.2.4.4.2" ::= { tssInductiveLoop 2 } loopOutputConditioningEntry OBJECT-TYPE SYNTAX LoopOutputConditioningEntry ACCESS not-accessible STATUS deprecated DESCRIPTION " Each table row contains inductive loop detector sensor zone output conditioning parameters. 1.3.6.1.4.1.1206.4.2.4.4.2.1" INDEX { sensorZoneNumber } ::= { loopOutputConditioningTable 1 } LoopOutputConditioningEntry ::= SEQUENCE { zoneOutputMode INTEGER, zoneMaxPresenceTime INTEGER, zoneOutputDelayTime INTEGER, zoneOutputExtendTime INTEGER, zoneOutputExtendEnable OCTET STRING, zoneOutputDelayEnable OCTET STRING } -- This object has been deprecated. See Annex D for more information. zoneOutputMode OBJECT-TYPE SYNTAX INTEGER { other (1), pulse (2), presence (3) } ACCESS read-write STATUS deprecated DESCRIPTION " This object sets the length of the output during a detect condition. These detect outputs are described as follows: Other - an output mode other than that defined in NTCIP 1209 v02. Pulse - a pulse of 125ms (25ms) is output when a vehicle is detected. Presence - the output lasts the duration of a detect condition or until the detector tunes out the detect signal. A value of 255 shall be returned to represent invalid data. If this object is supported, it is required to use the same data that is used by the new object outputConditioningEntry.sensorZoneOutputMode. 1.3.6.1.4.1.1206.4.2.4.4.2.1.1" ::= { loopOutputConditioningEntry 1 } -- This object has been deprecated. See Annex D for more information. zoneMaxPresenceTime OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS deprecated DESCRIPTION " This object sets the maximum time that the zone holds presence before retuning. Values of 1 to 65534 seconds are available. A value of 0 disables this timer and prevents a sensor zone occupancy from being tuned out at the end of a specific time. A value of 65,535 represents invalid data. If this object is supported, it is required to use the same data that is used by the new object outputConditioningEntry.sensorZoneMaxPresenceTime. second 1.3.6.1.4.1.1206.4.2.4.4.2.1.2" ::= { loopOutputConditioningEntry 2 } -- This object has been deprecated. See Annex D for more information. zoneOutputDelayTime OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS deprecated DESCRIPTION " The output for the zone is delayed from start of sensor zone occupancy by the time specified (tenths of a second: 00.0 to 6553.5 sec). For the output to actually switch, the sensor zone occupancy is required to be continuous and still be present at the end of the delay time. If this object is supported, it is required to use the same data that is used by the new object outputConditioningEntry.sensorZoneOutputDelayTime. tenths of a second 1.3.6.1.4.1.1206.4.2.4.4.2.1.3" REFERENCE "NEMA TS2 Clause 3.5.5.5.4.c and 6.5.2.24.1" ::= { loopOutputConditioningEntry 3 } -- This object has been deprecated. See Annex D for more information. zoneOutputExtendTime OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS deprecated DESCRIPTION " The output for the zone is extended, after the end of the period in which the sensor zone is occupied, by the amount of time specified (tenths of a second: 00.0 to 6553.5 sec). If this object is supported, it is required to use the same data that is used by the new object outputConditioningEntry.sensorZoneOutputExtendTime. tenths of a second 1.3.6.1.4.1.1206.4.2.4.4.2.1.4" REFERENCE "NEMA TS2 Clause 3.5.5.5.4.d and 6.5.2.24.2" ::= { loopOutputConditioningEntry 4 } --This object has been deprecated. See Annex D for more information. zoneOutputExtendEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-write STATUS deprecated DESCRIPTION " A bit-mapped value as defined below to enable and disable the extend time for the sensor zone output, as follows: bit 7 0 = NO, 1 = YES HIGH on output 1 Arming Pin to enable extend time for the zone (MSB), bit 6 0 = NO, 1 = YES HIGH on output 2 Arming Pin to enable extend time for the zone, bit 5 0 = NO, 1 = YES HIGH on output 3 Arming Pin to enable extend time for the zone, bit 4 0 = NO, 1 = YES HIGH on output 4 Arming Pin to enable extend time for the zone, bit 3 0 = NO, 1 = YES LOW on output 1 Arming Pin to enable extend time for the zone (MSB), bit 2 0 = NO, 1 = YES LOW on output 2 Arming Pin to enable extend time for the zone, bit 1 0 = NO, 1 = YES LOW on output 3 Arming Pin to enable extend time for the zone, bit 0 0 = NO, 1 = YES LOW on output 4 Arming Pin to enable extend time for the zone (LSB). Extend time is always enabled for the zone if all bits are zero (0). If this object is supported, it must use the same data that will be used by the new objects outputConditioningEntry.sensorZoneOutputExtendMode and outputConditioningEntry.sensorZoneOutputExtendEnables to the extent possible. 1.3.6.1.4.1.1206.4.2.4.4.2.1.5" REFERENCE "NEMA TS2 Clause 6.5.2.8.7, 6.5.2.24 and 6.5.2.25.6" ::= { loopOutputConditioningEntry 5 } --This object has been deprecated. See Annex D for more information. zoneOutputDelayEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-write STATUS deprecated DESCRIPTION " A bit-mapped value as defined below to enable and disable the delay time for the sensor zone output, as follows: bit 7 0 = NO, 1 = YES HIGH on output 1 Arming Pin to enable delay time for the zone (MSB), bit 6 0 = NO, 1 = YES HIGH on output 2 Arming Pin to enable delay time for the zone, bit 5 0 = NO, 1 = YES HIGH on output 3 Arming Pin to enable delay time for the zone, bit 4 0 = NO, 1 = YES HIGH on output 4 Arming Pin to enable delay time for the zone, bit 3 0 = NO, 1 = YES LOW on output 1 Arming Pin to enable delay time for the zone (MSB), bit 2 0 = NO, 1 = YES LOW on output 2 Arming Pin to enable delay time for the zone, bit 1 0 = NO, 1 = YES LOW on output 3 Arming Pin to enable delay time for the zone, bit 0 0 = NO, 1 = YES LOW on output 4 Arming Pin to enable delay time for the zone, Delay time is always enabled for the zone if all bits are zero (0). If this object is supported, it is required to use the same data that is used by the new objects outputConditioningEntry.sensorZoneOutputDelayMode and outputConditioningEntry.sensorZoneOutputDelayEnables to the extent possible. 1.3.6.1.4.1.1206.4.2.4.4.2.1.6" REFERENCE "NEMA TS2 Clause 6.5.2.8.7, 6.5.2.24 and 6.5.2.25.6" ::= { loopOutputConditioningEntry 6 } loopSystemStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF LoopSystemStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " This table contains inductive loop detector sensor zone status parameters. The number of rows in this table does not exceed maxSensorZones. This table contains instantaneous zone status objects specific to inductive loop detectors. The zoneDetectStatus object may be used by external systems for doing detailed traffic analysis. A zone maps directly to an output on an inductive loop detector - Zones 1 maps to output 1, Zone 2 maps to output 2, and, on a four output inductive loop detector, Zone 3 maps to output 3 and Zone 4 maps to output 4. Table rows are set by the manufacturer, and row creation/deletion is not supported. static 1.3.6.1.4.1.1206.4.2.4.4.3" ::= { tssInductiveLoop 3 } loopSystemStatusEntry OBJECT-TYPE SYNTAX LoopSystemStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Rows in this table contain inductive loop detector sensor zone status parameters. The number of rows in this table does not exceed maxSensorZones. Table rows are set by the manufacturer, and row creation/deletion is not supported. 1.3.6.1.4.1.1206.4.2.4.4.3.1" INDEX { sensorZoneNumber } ::= { loopSystemStatusTable 1 } LoopSystemStatusEntry ::= SEQUENCE { zoneInductance INTEGER, zoneFrequency INTEGER, zoneInductanceChange INTEGER, zoneFaultHistory BITMAP8, zoneFaultCount INTEGER, zonePercentInductanceChange INTEGER } zoneInductance OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS optional DESCRIPTION " The detector unit calculates the inductance of the loop attached to the zone. The resolution is in tenths of a microHenry. For example, 852.4 microHenries is represented as 8524. Resolution does not imply accuracy, refer to manufacturers' data sheet. A value of 65535 shall be returned to represent invalid data or not a physical zone. tenths of a microHenry 1.3.6.1.4.1.1206.4.2.4.4.3.1.1" ::= { loopSystemStatusEntry 1 } zoneFrequency OBJECT-TYPE SYNTAX INTEGER (0..16777216) ACCESS read-only STATUS optional DESCRIPTION " This is the frequency of the inductive loop attached to the zone. The frequency resolution is one-tenth hertz. For example, 53240 Hz is represented as 532400. Resolution does not imply accuracy, refer to manufacturers' data sheet. A value of 16777216 shall be returned to represent invalid data or not a physical zone. one-tenth Hertz 1.3.6.1.4.1.1206.4.2.4.4.3.1.2" ::= { loopSystemStatusEntry 2 } zoneInductanceChange OBJECT-TYPE SYNTAX INTEGER (0..8388608) ACCESS read-only STATUS optional DESCRIPTION " The maximum inductance change seen since the last start of sensor zone occupancy is returned. The resolution is to one nanoHenry. Resolution does not imply accuracy. nanoHenry 1.3.6.1.4.1.1206.4.2.4.4.3.1.3" ::= { loopSystemStatusEntry 3 } zoneFaultHistory OBJECT-TYPE SYNTAX BITMAP8 ACCESS read-only STATUS mandatory DESCRIPTION " A bit-mapped value representing the history of faults in Zone since the last unit reset. bit 7 0 = NO, 1 = YES To indicate that a current fault exists on the loop connected to the zone (MSB); bit 6 0 = NO, 1 = YES To indicate that the loop connected to the zone is open or this was the last fault. (May be also be called a Maximum Presence fault by external units.); bit 5 0 = NO, 1 = YES To indicate that the loop connected to the zone is shorted or this was the last fault. (May also be called a No Activity fault by external units.); bit 4 0 = NO, 1 = YES To indicate that the loop inductance of the loop connected to the zone is currently  25% of reference or this was the last fault. (May also be called a Erratic Count fault by external units.); bits 3..1 Reserved; bit 0 0 = NO, 1 = YES To indicate that data for this value is invalid data or this is not a physical zone (LSB). 1.3.6.1.4.1.1206.4.2.4.4.3.1.4" ::= { loopSystemStatusEntry 4 } zoneFaultCount OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " Number of faults in the zone since the last unit reset. These faults include open circuit; short circuit and 25% drift faults. The fault count may also include faults other than those defined in NTCIP 1209 v02. The count after 255 is 255. fault 1.3.6.1.4.1.1206.4.2.4.4.3.1.5" ::= { loopSystemStatusEntry 5 } zonePercentInductanceChange OBJECT-TYPE SYNTAX INTEGER (0..100000) ACCESS read-only STATUS mandatory DESCRIPTION " The maximum inductance change seen since the last start of sensor zone occupancy is returned. The resolution is to one one-thousandth of a percent. Resolution does not imply accuracy. For example a change of 0.1 percent would be represented as 100. one one-thousandth of a percent 1.3.6.1.4.1.1206.4.2.4.4.3.1.6" ::= { loopSystemStatusEntry 6 } tssMachineVision OBJECT IDENTIFIER ::={tss 5} -- This node contains the configuration objects specific to machine vision -- detectors -- 1.3.6.1.4.1.1206.4.2.4.5 maxCameraCount OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " This is the maximum number of machine vision cameras supported by the system. 1.3.6.1.4.1.1206.4.2.4.5.1" ::= { tssMachineVision 1 } machineVisionCameraTable OBJECT-TYPE SYNTAX SEQUENCE OF MachineVisionCameraEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " This table contains camera parameters. The number of rows in this table does not exceed maxCameraCount. This table contains the configuration objects specific to machine vision cameras. Table rows are set by the manufacturer, and row creation/deletion is not supported. Static 1.3.6.1.4.1.1206.4.2.4.5.2" ::= { tssMachineVision 2 } machineVisionCameraEntry OBJECT-TYPE SYNTAX MachineVisionCameraEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Row in table that contains machine vision camera parameters. The number of rows in this table does not exceed maxCameraCount. Table rows are set by the manufacturer, and row creation/deletion is not supported. 1.3.6.1.4.1.1206.4.2.4.5.2.1" INDEX { cameraNumber } ::= { machineVisionCameraTable 1 } MachineVisionCameraEntry ::= SEQUENCE { cameraNumber INTEGER, cameraNameLabel OCTET STRING, imageReceptionDiagnostic INTEGER, cameraDetectionState INTEGER, zoneListForCamera BITMAP256, baselineImage INTEGER, snapshotImage INTEGER, cameraImageFormat BITMAP32 } cameraNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The numerical label or number of the machine vision camera. This number shall not exceed the maxCameraCount data element value. 1.3.6.1.4.1.1206.4.2.4.5.2.1.1" ::= { machineVisionCameraEntry 1 } cameraNameLabel OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8..255)) ACCESS read-write STATUS mandatory DESCRIPTION " A text string used to describe the camera name or location. A camera name shall be a string length of less than 255 characters. 1.3.6.1.4.1.1206.4.2.4.5.2.1.2" ::= { machineVisionCameraEntry 2 } imageReceptionDiagnostic OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION " Image Reception Diagnostics is a measure of the health of the image transition link from the camera to the machine vision processor. A value of 100 means that all of the frames are being received and a value of 0 means that frames are not being received. Values between 0 and 100 are manufacturer-specific. This is used to track and debug transmission errors from the camera to the machine vision processor. 1.3.6.1.4.1.1206.4.2.4.5.2.1.3" ::= { machineVisionCameraEntry 3 } cameraDetectionState OBJECT-TYPE SYNTAX INTEGER { detectionIsNotDisabled (1), detectionIsDisabled (2) } ACCESS read-write STATUS mandatory DESCRIPTION " A camera can be enabled/disabled so that it may be used for other purposes such as surveillance. A disabled camera puts the associated zones in failsafe mode. If a pole has been hit and the camera is no longer looking at the traffic this can be used to put all the zones associated with that camera in failsafe mode. It can also be used for pan-tilt-zoom camera to disable detection so that the camera may be used for surveillance allowing the camera to look at areas other than the detection area. Enabling the camera places all the zones associated with that camera back into their defined detection mode. 1.3.6.1.4.1.1206.4.2.4.5.2.1.4" ::= { machineVisionCameraEntry 4 } zoneListForCamera OBJECT-TYPE SYNTAX BITMAP256 ACCESS read-only STATUS mandatory DESCRIPTION " This is a bit map where a 1 in a bit position indicates that zone is with the selected camera. The least significant bit (bit 0) of the first octet (byte) shall represent zone 1 and bit 6 of the 32nd octet (byte) shall represent zone 255. The most significant bit of the 32nd octet (byte) is reserved and shall not be set. 1.3.6.1.4.1.1206.4.2.4.5.2.1.5" ::= { machineVisionCameraEntry 5 } baselineImage OBJECT-TYPE SYNTAX INTEGER { notSupported (1), supportedAndAvailable (2), supportedButNotAvailable (3) } ACCESS read-only STATUS mandatory DESCRIPTION " Determines whether the machine vision camera supports a baseline image and the status of that image. 1.3.6.1.4.1.1206.4.2.4.5.2.1.6" ::= { machineVisionCameraEntry 6 } snapshotImage OBJECT-TYPE SYNTAX INTEGER { notSupported (1), supported (2) } ACCESS read-only STATUS mandatory DESCRIPTION " This data element determines whether the machine vision camera supports a snapshot image. notSupported(1) - Indicates that the machine vision camera does not support snapshot images. supported(2) - Indicates that the machine vision camera supports snapshot images. 1.3.6.1.4.1.1206.4.2.4.5.2.1.7" ::= { machineVisionCameraEntry 7 } cameraImageFormat OBJECT-TYPE SYNTAX BITMAP32 ACCESS read-only STATUS mandatory DESCRIPTION " Defines the types of image formats that the machine vision camera supports. bit 0 0 = NO, 1 = YES Indicates that the machine vision camera supports bitmap imagery; bit 1 0 = NO, 1 = YES Indicates that the machine vision camera supports JPEG imagery; bits 2..31 Reserved. 1.3.6.1.4.1.1206.4.2.4.5.2.1.8" ::= { machineVisionCameraEntry 8 } imageZoneNumber OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS optional DESCRIPTION " The numerical label or number representing the sensor zone number that is associated with the image. A value of zero (0) indicates that no sensor zone number is selected. When read, this data element returns the last value written. 1.3.6.1.4.1.1206.4.2.4.5.3" ::= { tssMachineVision 3 } imageType OBJECT-TYPE SYNTAX INTEGER { snapshot (1), baseline (2) } ACCESS read-write STATUS mandatory DESCRIPTION " This data element set the type of image to generate: Snapshot(1) - Snapshot indicates to capture a current image to transmit; Baseline(2) - Baseline indicates to use the baseline image used to set up the system for transfer. 1.3.6.1.4.1.1206.4.2.4.5.4" ::= { tssMachineVision 4 } imageOverlayType OBJECT-TYPE SYNTAX INTEGER { none (1), thisZone (2), allZones (3), defaultOverlay (4) } ACCESS read-write STATUS optional DESCRIPTION " This data element sets the type of image overlay to generate: none(1) - No overlay is generated in to the image; thisZone(2) - Indicates that an overlay is generated in the image indicating the location of this zone. The overlay specifics are manufacturer dependent; allZones(3) - Indicates that an overlay is generated in the image indicating the location of all zones associated with the camera. The overlay specifics are manufacturer dependent; defaultOverlay(4) - Indicates the manufacturer generates its default overlay in to the image. 1.3.6.1.4.1.1206.4.2.4.5.5" ::= { tssMachineVision 5 } imageFormat OBJECT-TYPE SYNTAX INTEGER { bitmap (1), jpeg (2) } ACCESS read-write STATUS optional DESCRIPTION " Identifies what format to return the machine vision camera image in. 1.3.6.1.4.1.1206.4.2.4.5.6" ::= { tssMachineVision 6 } imageQuality OBJECT-TYPE SYNTAX INTEGER (1..100) ACCESS read-write STATUS optional DESCRIPTION " This data element is used to select the image quality. The meaning varies based on the Image Format. A value of 100 selects the highest quality available. A value of 1 selects the lowest quality available. Lower quality may mean smaller more compressed images. Some image formats do not support variable image quality so the value is ignored. If a manufacturer supports only two image qualities for a specific image format then values 1 to 50 should select the lower quality while values 51 to 100 should select the higher quality. 1.3.6.1.4.1.1206.4.2.4.5.7" ::= { tssMachineVision 7 } buildImageCmd OBJECT-TYPE SYNTAX INTEGER { buildImage (1), cancelBuildInProgress (2) } ACCESS read-write STATUS optional DESCRIPTION " Writing the value buildImage to this data element commands the sensor to build an image based on the preceding parameters. A read of this data element always returns the last written. Values for this command are: buildImage(1) - This command shall cause the unit to build an image that can be read. cancelBuildInProgress(2) - This command shall cause the unit to cancel the current building process. 1.3.6.1.4.1.1206.4.2.4.5.8" ::= { tssMachineVision 8 } buildImageStatus OBJECT-TYPE SYNTAX INTEGER { noImage (1), buildingImage (2), imageReady (3), genericError (4), invalidParameter (5), noCameraForZone (6), multipleCamerasForZone (7), imageReceiveError (8), buildPending (9) } ACCESS read-only STATUS optional DESCRIPTION " Reading the value buildImageStatus from this data element yields the status of the current image to be read: noImage(1) - No Image is available for reading. This is the initial state if the buildImageCmd command has not been issued; buildingImage(2) - The sensor is in the progress of building the image. It is not ready yet; imageReady(3) - The image is ready for transfer. The last build command completed successfully; genericError(4) - An error occurred generating an image and there is not a more descriptive status code available to describe it; invalidParameter(5) - One of the Image Setup Data parameters is invalid; noCameraForZone(6) - The zone selected does not have a camera associated with it; multipleCamerasForZone(7) - There is more than one camera associated with the zone. To build an image you must select a zone with one and only one camera; imageReceiveError(8) - The sensor is having trouble receiving an image from its camera. This could be bad sync or other transmission problems; buildPending(9) - The sensor cannot begin the requested build at this time. The build begins when the blocking condition was ended. This can occur if the current image is in use (e.g., being transferred). 1.3.6.1.4.1.1206.4.2.4.5.9" ::= { tssMachineVision 9 } END