-- OIDref derived MIB transcription. Original PDF: https://www.ntcip.org/file/2018/11/NTCIP1206v0123f.pdf
-- Publisher front matter and notices follow as comments.
--                            A Joint Standard of AASHTO, ITE, and NEMA
-- 
-- 
-- 
-- 
--                        NTCIP 1206:2005                                     v01.23
-- 
-- 
-- 
--        National Transportation
--        Communications for ITS Protocol
-- 
--        Object Definitions for
--        Data Collection and
--        Monitoring (DCM) Devices
-- 
--                                                    November 2005
-- 
-- 
--          This Adobe® PDF copy of an NTCIP standard is available at no-cost for a limited
--          time through support from the U.S. DOT / Federal Highway Administration, whose
--          assistance is gratefully acknowledged.
-- 
-- 
-- 
-- 
-- Published by
-- 
-- American Association of State Highway and Transportation Officials (AASHTO)
-- 444 North Capitol Street, N.W., Suite 249
-- Washington, D.C. 20001
-- 
-- Institute of Transportation Engineers (ITE)
-- 1099 14th Street, N.W., Suite 300 West
-- Washington, D.C. 20005-3438
-- 
-- National Electrical Manufacturers Association (NEMA)
-- 1300 North 17th Street, Suite 1752
-- Rosslyn, Virginia 22209-3806
-- 
-- 
-- 
--  2005 AASHTO / ITE / NEMA. All rights reserved.
-- 
--                                                    NOTICES
-- 
-- Copyright Notice
-- 
--  2005 by the American Association of State Highway and Transportation Officials (AASHTO), the
-- Institute of Transportation Engineers (ITE), and the National Electrical Manufacturers Association
-- (NEMA). All intellectual property rights, including, but not limited to, the rights of reproduction, translation,
-- and display are reserved under the laws of the United States of America, the Universal Copyright
-- Convention, the Berne Convention, and the International and Pan American Copyright Conventions.
-- Except as licensed or permitted, you may not copy these materials without prior written permission from
-- AASHTO, ITE, or NEMA. Use of these materials does not give you any rights of ownership or claim of
-- copyright in or to these materials.
-- 
-- Visit www.ntcip.org for other copyright information, for instructions to request reprints of excerpts, and to
-- request reproduction that is not granted below.
-- 
-- 
-- PDF File License Agreement
-- 
-- To the extent that these materials are distributed by AASHTO / ITE / NEMA in the form of an Adobe®
-- Portable Document Format (PDF) electronic data file (the “PDF File”), AASHTO / ITE / NEMA authorizes
-- each registered PDF File user to view, download, copy, or print the PDF File available from the
-- authorized Web site, subject to the terms and conditions of this license agreement:
-- 
-- (a) you may download one copy of each PDF File for personal, noncommercial, and intraorganizational
-- use only;
-- (b) ownership of the PDF File is not transferred to you; you are licensed to use the PDF File;
-- (c) you may make one more electronic copy of the PDF File, such as to a second hard drive or burn to a
-- CD;
-- (d) you agree not to copy, distribute, or transfer the PDF File from that media to any other electronic
-- media or device;
-- (e) you may print one paper copy of the PDF File;
-- (f) you may make one paper reproduction of the printed copy;
-- (g) any permitted copies of the PDF File must retain the copyright notice, and any other proprietary
-- notices contained in the file;
-- (h) the PDF File license does not include (1) resale of the PDF File or copies, (2) republishing the content
-- in compendiums or anthologies, (3) publishing excerpts in commercial publications or works for hire,
-- (4) editing or modification of the PDF File except those portions as permitted, (5) posting on network
-- servers or distribution by electronic mail or from electronic storage devices, and (6) translation to other
-- languages or conversion to other electronic formats;
-- (i) other use of the PDF File and printed copy requires express, prior written consent.
-- 
-- 
-- Data Dictionary and MIB Distribution Permission
-- 
-- To the extent that these materials are distributed by AASHTO / ITE / NEMA in the form of a Data
-- Dictionary (“DD”) or Management Information Base (“MIB”), AASHTO / ITE / NEMA extend the following
-- permission:
-- 
-- You may make and/or distribute unlimited copies, including derivative works, of the DD or MIB, including
-- copies for commercial distribution, provided that:
-- (i) each copy you make and/or distribute contains the citation “Derived from NTCIP 0000 [insert the
-- document number]. Used by permission of AASHTO / ITE / NEMA.”;
-- 
-- 
-- 
-- 
-- Do Not Copy Withot Written Permission                                             © 2005 AASHTO / ITE / NEMA
-- 
-- (ii) the copies or derivative works are not made part of the standards publications or works offered by
-- other standards developing organizations or publishers or as works-for-hire not associated with
-- commercial hardware or software products intended for field implementation;
-- (iii) use of the DD or MIB is restricted in that the syntax fields may be modified only to reflect a more
-- restrictive subrange or enumerated values;
-- (iv) the description field may be modified but only to the extent that: (a) only those bit values or
-- enumerated values that are supported are listed; and (b) the more restrictive subrange is expressed.
-- 
-- These materials are delivered “AS IS” without any warranties as to their use or performance.
-- 
-- AASHTO / ITE / NEMA and their suppliers do not warrant the performance or results you may
-- obtain by using these materials. AASHTO / ITE / NEMA and their suppliers make no warranties,
-- express or implied, as to noninfringement of third party rights, merchantability, or fitness for any
-- particular purpose. In no event will AASHTO / ITE / NEMA or their suppliers be liable to you or any
-- third party for any claim or for any consequential, incidental or special damages, including any
-- lost profits or lost savings, arising from your reproduction or use of these materials, even if an
-- AASHTO / ITE / NEMA representative has been advised of the possibility of such damages.
-- 
-- Some states or jurisdictions do not allow the exclusion or limitation of incidental, consequential or special
-- damages, or the exclusion of implied warranties, so the above limitations may not apply to you.
-- 
-- Use of these materials does not constitute an endorsement or affiliation by or between AASHTO, ITE, or
-- NEMA and you, your company, or your products and services.
-- 
-- If you are unwilling to accept the foregoing restrictions, you should immediately return these materials.
-- 
-- 
-- PRL and RTM Distribution Permission
-- 
-- To the extent that these materials are distributed by AASHTO / ITE / NEMA in the form of a Profile
-- Requirements List (“PRL”) or a Requirements Traceability Matrix (“RTM”), AASHTO / ITE / NEMA extend
-- the following permission:
-- 
-- (i) you may make and/or distribute unlimited copies, including derivative works of the PRL (then known as
-- a Profile Implementation Conformance Statement (“PICS”)) or the RTM, provided that each copy you
-- make and/or distribute contains the citation “Based on NTCIP 0000 [insert the document number] PRL or
-- RTM. Used by permission. Original text (C) AASHTO / ITE / NEMA.”;
-- (ii) you may not modify the PRL or the RTM except for the Project Requirements column, which is the
-- only column that may be modified to show a product’s implementation or the project-specific
-- requirements; and
-- (iii) if the PRL or RTM excerpt is made from an unapproved draft, add to the citation “PRL (or RTM)
-- excerpted from a draft document containing preliminary information that is subject to change.”
-- 
-- This limited permission does not include reuse in works offered by other standards developing
-- organizations or publishers, and does not include reuse in works-for-hire, compendiums, or electronic
-- storage devices that are not associated with commercial hardware or software products intended for field
-- installation.
-- 
-- A PICS is a Profile Requirements List which is completed to indicate the features that are supported in an
-- implementation. Visit www.ntcip.org for information on electronic copies of the MIBs, PRLs, and RTMs.
-- 
-- 
-- Content and Liability Disclaimer
-- 
-- 
-- 
-- 
-- © 2005 AASHTO / ITE / NEMA                                             Do Not Copy Without Written Permission
-- 
-- The information in this publication was considered technically sound by the consensus of persons
-- engaged in the development and approval of the document at the time it was developed. Consensus
-- does not necessarily mean that there is unanimous agreement among every person participating in the
-- development of this document.
-- 
-- AASHTO, ITE, and NEMA standards and guideline publications, of which the document contained herein
-- is one, are developed through a voluntary consensus standards development process. This process
-- brings together volunteers and/or seeks out the views of persons who have an interest in the topic
-- covered by this publication. While AASHTO, ITE, and NEMA administer the process and establish rules
-- to promote fairness in the development of consensus, they do not write the document and they do not
-- independently test, evaluate, or verify the accuracy or completeness of any information or the soundness
-- of any judgments contained in their standards and guideline publications.
-- 
-- AASHTO, ITE, and NEMA disclaim liability for any personal injury, property, or other damages of any
-- nature whatsoever, whether special, indirect, consequential, or compensatory, directly or indirectly
-- resulting from the publication, use of, application, or reliance on this document. AASHTO, ITE, and
-- NEMA disclaim and make no guaranty or warranty, express or implied, as to the accuracy or
-- completeness of any information published herein, and disclaims and makes no warranty that the
-- information in this document will fulfill any of your particular purposes or needs. AASHTO, ITE, and
-- NEMA do not undertake to guarantee the performance of any individual manufacturer or seller’s products
-- or services by virtue of this standard or guide.
-- 
-- In publishing and making this document available, AASHTO, ITE, and NEMA are not undertaking to
-- render professional or other services for or on behalf of any person or entity, nor are AASHTO, ITE, and
-- NEMA undertaking to perform any duty owed by any person or entity to someone else. Anyone using this
-- document should rely on his or her own independent judgment or, as appropriate, seek the advice of a
-- competent professional in determining the exercise of reasonable care in any given circumstances.
-- Information and other standards on the topic covered by this publication may be available from other
-- sources, which the user may wish to consult for additional views or information not covered by this
-- publication.
-- 
-- AASHTO, ITE, and NEMA have no power, nor do they undertake to police or enforce compliance with the
-- contents of this document. AASHTO, ITE, and NEMA do not certify, test, or inspect products, designs, or
-- installations for safety or health purposes. Any certification or other statement of compliance with any
-- health or safety–related information in this document shall not be attributable to AASHTO, ITE, or NEMA
-- and is solely the responsibility of the certifier or maker of the statement.
-- 
-- 
-- Trademark Notice
-- 
-- NTCIP is a trademark of AASHTO / ITE / NEMA. All other marks mentioned in this document are the
-- trademarks of their respective owners.
-- 
-- 
-- 
-- 
-- Do Not Copy Withot Written Permission                                      © 2005 AASHTO / ITE / NEMA
-- 
--                                                                                     NTCIP 1206:2005 v01.23
--                                                                                                     Page i
-- 
--                                         ACKNOWLEDGEMENTS
-- 
-- 
-- This publication was prepared by the NTCIP Data Collection and Monitoring (DCM) Working Group,
-- which is a subdivision of the Joint Committee on the NTCIP. The Joint Committee is organized under a
-- Memorandum of Understanding among the American Association of State Highway and Transportation
-- Officials (AASHTO), the Institute of Transportation Engineers (ITE), and the National Electrical
-- Manufacturers Association (NEMA). The Joint Committee on the NTCIP consists of six representatives
-- from each of the standards organizations, and provides guidance for NTCIP development.
-- 
-- At the time that this document was prepared, the following individuals were active members of the NTCIP
-- DCM Working Group:
--      • Ralph Gillmann
--      • Dan Gossack
--      • Jason Hedley
--      • Andrew Pratt
--      • Joerg ‘Nu’ Rosenbohm
--      • Rick Stalowski, Chair
--      • Paul Stein
--      • Douglas Terhune
--      • LJ Wilkinson
-- 
-- Other individuals providing input to the document include:
--    • Blake Christie (Mitretek)
--    • Ron Koenderink (IRD)
-- 
-- In addition to the many volunteer efforts, recognition is also given to those organizations who supported
-- the efforts of the working groups by providing comments and funding for the standard, including:
--     • Alaska DOT and Public Facilities
--     • Chaparral Systems
--     • Federal Highway Administration-HPPI 30
--     • Golden River Traffic Ltd.
--     • International Road Dynamics Inc. (IRD)
--     • Iowa State University (CTRE)
--     • ITERIS, Inc
--     • PB Farradyne, a Division of PBQD
--     • PEEK Traffic
--     • TimeMark Inc.
--     • TrafInfo Communications, Inc.
--     • U.S. Department of Transportation Federal Highway Administration JPO
--     • Wisconsin Department of Transportation (WIDOT)
-- 
-- 
-- 
-- 
-- © 2005 AASHTO / ITE / NEMA                                            Do Not Copy Without Written Permission
-- 
-- NTCIP 1206:2005 v01.23
-- Page ii
-- 
--                                              FOREWORD
-- 
-- 
-- This document references both imperial and metric units; however, all objects are defined using metric
-- units.
-- 
-- This document defines the management information for a Data Collection and Monitoring (DCM) unit.
-- The term DCM includes a range of devices — from traditional traffic counters on the simple end, to more
-- complicated devices such as weigh-in-motion field units. This document defines individual parameters
-- that represent the configuration, status, and control information that are unique to DCMs. This document
-- also defines specific groupings of these parameters and others to address the operational configuration,
-- monitoring, and control of the device in a baseline system configuration.
-- 
-- There are four annexes to this document. Annex A is normative; all other annexes are informative.
-- 
-- This document is an NTCIP Device Data Dictionary Standard. Device Data Dictionaries Standards define
-- management information in terms of objects (data elements, data frames, and messages) for use within
-- NTCIP systems. A Joint NTCIP Device Data Dictionary standards publication is equivalent to these
-- document types at the standards organizations:
-- 
--         AASHTO – Standard Specification
--         ITE – Software Standard
--         NEMA – Standard
-- 
-- For more information about NTCIP standards, visit the NTCIP Web site at http://www.ntcip.org.
-- 
-- 
-- User Comment Instructions
-- 
-- The term “User Comment” includes any type of written inquiry, comment, question, or proposed revision,
-- from an individual person or organization, about any part of this standard publication’s content. A
-- “Request for Interpretation” of this standard publication is also classified as a User Comment. User
-- Comments are solicited at any time. In preparation of this NTCIP standards publication, input of users
-- and other interested parties was sought and evaluated.
-- 
-- All User Comments will be referred to the committee responsible for developing and/or maintaining this
-- standards publication. The committee chairperson, or their designee, may contact the submitter for
-- clarification of the User Comment. When the committee chairperson or designee reports the committee’s
-- consensus opinion related to the User Comment, that opinion will be forwarded to the submitter. The
-- committee chairperson may report that action on the User Comment may be deferred to a future
-- committee meeting and/or a future revision of the standards publication. Previous User Comments and
-- their disposition may be available for reference and information at www.ntcip.org.
-- 
-- A User Comment should be submitted to this address:
-- 
--         NTCIP Coordinator
--         National Electrical Manufacturers Association
--         1300 North 17th Street, Suite 1752
--         Rosslyn, Virginia 22209-3806
--         fax:    (703) 841-3331
--         e-mail: ntcip@nema.org
-- 
-- 
-- 
-- 
-- Do Not Copy Without Written Permission                                      © 2005 AASHTO / ITE / NEMA
-- 
--                                                                                   NTCIP 1206:2005 v01.23
--                                                                                                  Page iii
-- 
-- A User Comment should be submitted in the following form:
-- 
--           Standard Publication number and version:
--           Page:
--           Paragraph or Clause:
--           Comment:
-- 
-- Please include your name, organization, and address in your correspondence.
-- 
-- 
-- Approvals
-- 
-- This document was separately balloted and approved by AASHTO, ITE, and NEMA after
-- recommendation by the Joint Committee on the NTCIP. Each organization has approved this standard
-- as the following standard type, as of the date:
-- 
--           AASHTO – Standard Specification; October 2004
--           ITE – Software Standard; May 2005
--           NEMA – Standard; November 2004
-- 
-- 
-- History
-- 
-- From 1997 to 1999, this document was referenced as TS 3.DCM. However, to provide an organized
-- numbering scheme for the NTCIP documents, this document is now referenced as NTCIP 1206. The
-- technical specifications of NTCIP 1206 are identical to the former reference, except as noted in the
-- development history below:
-- 
--           NTCIP 1206 v01.17. November 2001 – Accepted as a User Comment Draft by the Joint
--           Committee on the NTCIP. February 2002 – NTCIP Standards Bulletin B0072 distributed v01.18
--           for user comment.
-- 
--           NTCIP 1206 v01.21. November 2003 – Accepted v01.21 as a Recommended Standard by the
--           Joint Committee on the NTCIP. July 2004 – NTCIP Standards Bulletin B0095 referred v01.22b
--           for balloting. Approved by AASHTO in October 2004, approved by ITE in May 2005, and
--           approved by NEMA in November 2004.
-- 
--           NTCIP 1206:2005 v01.23. November 2005 – Edited document for publication; revised front
--           matter.
-- 
-- 
-- Compatibility of Versions
-- 
-- All NTCIP Standards Publications have a major and minor version number for configuration management.
-- The version number syntax is "v00.00a," with the major version number before the period, and the minor
-- version number and edition letter (if any) after the period.
-- 
-- Anyone using this document should seek information about the version number that is of interest to them
-- in any given circumstance. The MIB, the PRL, and the PICS should all reference the version number of
-- the standards publication that was the source of the excerpted material.
-- 
-- Compliant systems based on later, or higher, version numbers MAY NOT be compatible with compliant
-- systems based on earlier, or lower, version numbers. Anyone using this document should also consult
-- NTCIP 8004 for specific guidelines on compatibility.
-- 
-- 
-- 
-- 
-- © 2005 AASHTO / ITE / NEMA                                          Do Not Copy Without Written Permission
-- 
-- NTCIP 1206:2005 v01.23
-- Page iv
-- 
--                                               INTRODUCTION
-- 
-- 
-- This publication defines management information related to a Data Collection and Monitoring device.
-- DCM management information includes individual parameters that represent the configuration, status,
-- and control information of such a device. The objects are defined using several ASN.1 Macros that were
-- initially developed for use with Internet information management. The macros have been modified to
-- include additional information specific to NTCIP and ITS Data Dictionaries and Message Sets.
-- 
-- This standard defines requirements that are applicable to an NTCIP environment that involves the control
-- of roadside-bound devices. While the term ‘data collection and monitoring unit’ implies some type of
-- physical device, many of the data concepts are applicable to any logical implementation. By definition, a
-- DCM operates in the context of a "system" that includes roadside devices that are capable of
-- communicating and office-based transportation management center software. The standard, therefore,
-- imposes requirements on both of these "system" components.
-- 
-- The following keywords apply to this document: AASHTO, ITE, NEMA, NTCIP, DCM, weigh-in-motion,
-- WIM, traffic counters, vehicle classification, data binning
-- 
-- In 1992, the NEMA 3-TS Transportation Management Systems and Associated Control Devices Section
-- began the effort to develop the NTCIP. Under the guidance of the Federal Highway Administration’s
-- NTCIP Steering Group, the NEMA effort was expanded to include the development of communications
-- standards for all transportation field devices that could be used in an ITS network.
-- 
-- In September 1996, an agreement was executed among AASHTO, ITE, and NEMA to jointly develop,
-- approve, and maintain the NTCIP standards. The NTCIP Joint Committee established the Data
-- Collection and Monitoring Working Group (DCM WG) in order to define a common set of management
-- information related to roadside devices that collect traffic information on a non-real-time basis. The first
-- meeting of the working group was held in May 1998.
-- 
-- After considering all functionality that could be considered appropriate to a data collection and monitoring
-- device, the WG developed a work plan based on two phases. The initial phase sought to address the
-- information and operational requirements of configuring and monitoring DCM devices. Within the second
-- phase, the file structures to retrieve the collected and compounded data will be developed. This current
-- version of this standard includes the results of the both phases.
-- 
-- 
-- 
-- 
-- Do Not Copy Without Written Permission                                          © 2005 AASHTO / ITE / NEMA

DCM-MIB1 DEFINITIONS ::= BEGIN

--Import statements
IMPORTS
  Counter
  --, IpAddress
 FROM RFC1155-SMI
   OBJECT-TYPE
  FROM RFC-1212
   --DisplayString    -need to be REMed out when using with SMIC compiler
  -- FROM RFC-1213-MIB -need to be REMed when using with SMIC compiler
   --TRAP-TYPE
  -- FROM RFC-1215
   devices
  FROM TMIB-II
   --EntryStatus, OwnerString, OerString,
   --Byte, UByte, Short, Ushort, Long, Ulong
  --FROM NEMA-SMI
  --controller-localTime
 -- FROM GLOBAL-MIB;
;

--SMI OBJECT-TYPE
--DisplayString ::= OCTET STRING (SIZE(0..127))

--DCM-related Object Definitions
dcm OBJECT IDENTIFIER ::= {devices 9}




                                                                                        

                      
       



                                                
-- This section contains SNMPv1 ‘Type Assignments’. It provides a mechanism
-- to define a ‘Type’ once and allows for referencing of that defined type
-- in other object/table definitions.

                                              
DcmRowStatus ::= INTEGER
{
 active (1),
 notInService (2),
 notReady (3),
 createAndGo (4),
 createAndWait (5),
 destroy (6)
}
--This object is intended to provide the same functionality as the RowStatus
-- object defined in SNMPV2. It shall operate in the same manner as defined
-- in SNMPV2.
--
--The 'action' states can be written, but not read:
--createAndGo: indicates that the agent should accept the row values
-- specified,create items within the row and place the row into service (or
-- activate it)
--
--createAndWait: indicates that the agent should accept the values specified
-- (if any) and, create items within the row, but not place the row
-- in service.
--
--destroy: indicates that the agent should remove the row from service and
-- then delete it.
--
--The 'desired' states can be written and read:
--notInService: indicates that the row has been suspended. That is, the
-- row does not exist.
--
--active: indicates that the row exists and can be used.
--
--The 'current' state can only be read:
--notReady: indicates that the row does not contain values for all columnar
-- objects in the row that are needed for an agent to act upon.

                                          
DcmTimeTagIndex ::= INTEGER (0..4294967295)
--SMIC compiler will not allow using ‘counter’ as an index for tables.
-- There are table structures defined as not-accessible solely for
-- the purposes of data file storage. DcmTimeTagIndex should be the exact
-- definition as ‘counter’ from RFC1155.smi.

                                                
DcmMaxNumRows ::= INTEGER

--This value represents the maximum number of rows a table is allowed to have.

                                                
DcmCurNumRows ::= INTEGER



                                                                                  

                                                                                     
                                                                                    



--This value represents the current number of rows existing in a table.

                                         
DcmIOBoardNum ::= INTEGER (1..255)

--This value represents a unique number from the ‘dcm IO Board Configuration
-- Table’ for each IO Board that has been installed within the dcm device.
-- This number is assigned by the device and must be sequential.

                                           
DcmIOBoardFtn ::= INTEGER (1..255)

--This value represents the function of each specified IO board in the
-- IO Board Configuration Table.
-- This number is assigned by the device.

                                         
DcmLogIONum ::= INTEGER (1..255)

--Indicates a unique number assigned to each physical IO channel in the ‘dcm
-- Physical To Logical IO Mapping Table. It provides a link to this IO
-- channel for other objects/tables within this MIB as required. This is
-- assigned by the device (it is strongly recommended that it is assigned
-- sequentially).

                                            
DcmIOParamType ::= INTEGER
{
 other (1),
 debounce (2),
 deadtime (3),
 sensitivityGain (4),
 onThreshold (5),
 offThreshold (6),
 onHysteresis (7),
 offHysteresis (8),
 minOnTime (9),
 minOffTime (10),
 maxOnTime (11),
 maxOffTime (12),
 adOffset (13),
 scanTime (14),
 sensorLength (15),
 sensorWidth (16),
 sensorHeight (17),
 sensorDepth (18),
 sensorAngle (19),
 ioCal (20),
 frequency (21),
 memoryWrap (22),
 dataStorageMediaAvailable (23),
 dataStorageMediaUsed (24)
}
--An enumeration used to identify a type of IO Parameter.   Refer to
-- DcmIOParamValue for a description of each.




                                                                                        

                      
       



                                              
DcmIOParamValue ::= INTEGER

--Indicates the value for the selected IO parameter. These parameters are
--typically used to help process and make adjustments to an IO.    If an
--application tries to set an invalid value for a particular IO parameter, an
--application error code of ‘Out of range’ shall be set.

--The following further defines each parameter:
-- (ms=milliseconds, us=microseconds, mm=millimeters, Mhz=megahertz)
--other(1)=not defined below.
--debounce(2)= (0-65535ms) the amount of time that input transitions shall be
-- ignored relative to the last transition of the IO.
--deadtime(3)= (0-65535ms) the amount of time that input transitions shall be
-- ignored relative to the first transition of the IO.
--sensitivityGain(4)= (0-100%) the percent of full-scale to set an IO gain or
-- sensitivity adjustment
--onThreshold(5)= (0-100%) the percent of full-scale to set a level at which
-- an IO shall be considered active
--offThreshold(6)= (0-100%) the percent of full-scale to set a level at which
-- an IO shall be considered inactive
--onHysteresis(7), (0-100%) the percent of full-scale which sets a threshold
-- level above the ‘off’ point to trigger another ‘on’ to prevent an IO from
-- continuously turning on-off
--offHysteresis(8)= (0-100%) the percent of full-scale which sets a threshold
-- level below the ‘on’ point to trigger another ‘off’ to prevent an IO from
-- continuously turning on-off
--minOnTime(9)= (0-65535ms) the minimum amount of time an input must remain on
-- to be considered a valid on
--minOffTime(10)= (0-65535ms) the minimum amount of time an input must remain
-- off to be considered a valid off
--maxOnTime(11)= (0-16777215ms) the maximum amount of time an IO is allowed to
-- remain on before triggering an action (sensor input stuck on)
--maxOffTime(12)= (0-16777215ms) the maximum amount of time an IO is allowed
-- to remain off before triggering an action (sensor input stuck off)
--adOffset(13)= (0-100%) the percent of full-scale to set an analog to digital
-- converter’s offset voltage
--scanTime(14)= (0-3600000000us) the time frequency in which an IO channel is
-- sampled
--sensorLength(15)= (0-65535mm) the length of the active portion of an IO
-- oriented in the same direction as vehicles traverse the array
--sensorWidth(16)= (0-65535mm) the width of the active portion of an IO
-- oriented perpendicular to the direction of vehicles traversing the array
--sensorHeight(17)= (0-65535mm) the height above the roadway in which an IO is
-- mounted
--sensorDepth(18)= (0-65535mm) the depth below the roadway in which an IO is
-- mounted
--sensorAngle(19)= (0-1296000seconds) the angle in seconds (up to 360degrees)
-- which defines the angle of an IO
--ioCal(20), (0-100000) a multiplier in .001 between 0 and 100.000 used to
-- scale an IO
--frequency(21), (0-4294967295hz, 4 octets) the frequency assigned to an IO
--channel
--memoryWrap(22), (0=off, 1=on) enables/disables ‘memory wrap’ for the
-- specified storage media (memory wrap is defined as the process in which
-- older files are deleted or wrapped out from a storage media to make room
-- for newer files)
--dataStorageMediaAvailable(23)= (0-4294967295) indicates the number of bytes



                                                                                  

                                                                                     
                                                                                    



-- available on this storage media. This is a read-only parameter, writes to
-- this parameter shall be ignored (a dcm error code of readOnly shall be
set).
--dataStorageMediaUsed(24)= (0-4294967295) indicates the number of bytes used
-- on this storage media. This is a read-only parameter, writes to this
-- parameter shall be ignored (a dcm error code of readOnly shall be set).

--On % full scale values, the “GET” value may not be same as the requested
--“SET” value since the implemented scale is IO and device-specific. ”

2.2.10    Array Number (DcmArrayNum)
DcmArrayNum ::= INTEGER (1..255)

--This object represents a unique number for each sensor array that is defined
-- within the device in the ‘dcm Logical IO To Array Mapping Table’. It is
-- strongly suggested that the array numbers are assigned sequentially.

2.2.11    Array Parameter Type (DcmArrayParamType)
DcmArrayParamType ::= INTEGER
{
 other (1),
 maxAxleSpacing (2),
 vehicleAxleRatio (3),
 singleAxleTimeout (4),
 maxVehicleLength (5),
 wimCalFactor (6),
 calFilePointer (7),
 arraySpeedCal (8)
}
--Indicates the type of parameter associated with an array. One or more types
--can be associated with an array. The values are:
-- other (1),= not defined below.
-- maxAxleSpacing (2),= The longest axle spacing (in millimeters) that would
-- be expected on any vehicle to traverse the array. This parameter is
-- typically used to end a vehicle if there is no presence sensor used in the
-- array.
-- vehicleAxleRatio (3),= The number of detected axles which shall be
considered to
-- constitute a vehicle. This parameter is typically used in arrays that can
-- only detect axles.
-- singleAxleTimeout (4)= The amount of time from the last axle strike (in
-- milliseconds) that must elapse before another axle strike to end a
-- vehicle. This parameter is typically used with arrays that do not use a
-- presence sensor to separate vehicles or cannot calculate a speed to use
-- the maxAxleSpacing parameter.
-- maxVehicleLength (5),= This parameter defines the maximum expected vehicle
-- length (in mm) to traverse the sensor array. It is typically used to end
-- a vehicle in a situation where the sensor used to calculate vehicle
-- length may be stuck on.
-- wimCalFactor (6),= This parameter defines a multiplier (0.000 to 65.535) to
-- be applied to weights calculated by an array. This is a discrete number
-- and has no units.
-- calFilePointer (7)= The file name specified in the dcmParameterFileName
-- points to a file containing implementation-specific calibration parameters
-- (e.g. classification scheme, WIM autocalibration scheme). object. The
-- value of the dcmParameterValue shall be ignored.
-- arraySpeedCal (8) = this enumeration was added to allow encoding of an



                                                                                        

                      
       



--   array speed calibration change (refer to dcmArraySpeedCalFactor in the
--   ‘Array Speed Calibration Table’) to be encoded into the ‘Array Parmater
--   Change Record Table’ and written to a dcm data file. It shall not be used
--   in this table."

2.2.12    Array Parameter Value (DcmArrayParamValue)
 DcmArrayParamValue ::= INTEGER (0..16777215)

--Indicates the value associated with an array parameter type as
-- specified by a DcmArrayParamType object. The acceptable value ranges and
-- units differ depending on the value of the dcmParameterType object value.
-- The acceptable values and UNITs per parameter type are:
-- maxAxleSpacing = 0 to 65535 in millimeter
-- vehicleAxleRatio = 1.00 to 655.35 as a divisor (e.g., 2.00 specifies that 2
-- axles constitute 1 vehicle)
-- singleAxleTimeout = 0 to 65535 in milliseconds
-- maxVehicleLength = 0 to 65535 in millimeters
-- wimCalFactor = 0.000 to 100.000 as a multiplier
-- calFilePointer = The DcmArrayParamValue is meaningless when the
-- DcmArrayParamType object is set to ‘calFilePointer’. The
-- DcmArrayParamFileName object should be read to obtain an octet string
-- identifying the name of a file which contains implementation-specific
-- calibration factors.
-- arraySpeedCal= Refer to dcmArraySpeedCalFactor in the ‘Array Speed
-- Calibration Table’

2.2.13    Array Parameter File Name (DcmArrayParamFileName)
DcmArrayParamFileName ::= OCTET STRING (SIZE (0..255))

--Indicates a file name that contains array parameter calibration information.
-- This information is most likely implementation-specific. The value of this
-- object is only meaningful, if the value of the Array Parameter Type
-- (dcmAPType) object is set to ‘calFilePointer’, otherwise this value shall
-- be ignored.

2.2.14    Filter Number (DcmFilterNum)
DcmFilterNum ::= INTEGER (1..255)

--This object indicates a filter number assigned to filters defined within
-- this dcm device from the ‘dcm Filter Configuration Table’.

2.2.15    Study Number (DcmStudyNum)
DcmStudyNum ::= INTEGER (1..255)

--This object represents a unique number for each study that is defined within
-- the dcm device in the ‘dcm Study Configuration Table’. It is recommended
-- to assign this value sequentially, however when studies are deleted, there
-- could be gaps in the indexes. It is recommended to use the deleted study
-- number as the next one to assign as an attempt to keep these indexes
-- sequential.

2.2.16    File Study Index (DcmFileStudyIndex)
DcmFileStudyIndex ::= INTEGER (0..255)

--Identifies a file structure number defined within the ‘dcm File Structure
-- Table’. A value of zero (0) indicates that no data shall be recorded and



                                                                                        

                                                                                     
                                                                                    



-- the study is to be used for Monitor Modes.

2.2.17    File Structure Number (DcmFileStrucNum)
DcmFileStrucNum ::= INTEGER (1..255)

--This object points to a defined file structure in the ‘dcm File Structure
-- Table’. It is highly recommended that the application try to keep this
-- number sequential (reuse numbers that have been deleted).

2.2.18    Binned Filter Number (DcmBinnedFilterNum)
DcmBinnedFilterNum ::= INTEGER (1..255)

--This object represents a unique number for each binned filter that has been
-- defined in the ‘dcm Binned Filter Definition Table) within the device. It
-- is strongly suggested that the numbering is assigned sequentially. This
-- number can never exceed the maximum number of bins for all studies object
-- (dcmMaxNumBins).

2.3   VEHICLE CRITERIA NODE
--DCM Vehicle Criteria Node
dcmVehCriteria OBJECT IDENTIFIER ::= {dcm 1}

-- This node identifies the parameters that are used to define vehicle
-- criteria that can be used to configure Binned Studies, PVR Studies and
-- Filters.

-- These parameters are not intended to be manipulated directly by an
-- application. They are defined to allow assignment of an OID to reference
-- them in other places. They are defined in this section because they were
-- not required to be defined as regular objects elsewhere in this standard.

-- Objects defined as an Integer can be used in the Filter Config Table and
-- the Binned Filter Definition Table. Objects of any type can be used
-- in the PVR Study Configuration Table.

-- Even though an object is defined in this node, a device may not allow
-- using that object in one of the stated tables (as it may not be sensible).
-- The device shall return a dcm application error code of ‘invalidOption’
-- for any object not allowed in one of the tables.
-- The Vehicle Criteria Table shall indicate which vehicle parameters
-- (both within this MIB and externalto this MIB) are supported and for
-- what application (Binned Studies, PVR Studies or filters).

-- Note that objects that are only defined as elements of a table
-- (e.g. Array Number (DcmArrayNum)) may also be used within the
-- Vehicle Criteria Table. The OID’s for these type of objects should
-- be taken from the table from which that object is first defined
-- (e.g. Array Number is first defined in the Logical IO To Array Map Table
--   as dcmIOAMArrNum). Therefore if Array Number is supported by this
-- device, then the OID for dcmIOAMArrNum should be used in the
-- Vehicle Criteria Table. Other objects (within this standard) included
-- in this category are dcmPLMLogIONum and dcmFCFilterNum. The controller
-- local time zone object from the Global Objects (1201-2.4.7,
-- controller-localTime) is also included in this category.

-- Each object defined in this section can be either a single-occurrence or
-- multi-occurrence object when used to configure a PVR Study.


                                                                                        

                      
       



-- A single-occurrence object has only one instance when stored in the PVR
-- data (such as vehicle speed).
-- A multi-occurrence object shall consist of multiple occurrences of
-- the object (such as axle weights).
-- Unless otherwise specified, all objects shall be defined as a
-- single-occurrence object.

-- A single-occurrence object has only one instance of the
-- defined parameter in the PVR structure, it shall be encoded as [(value)].
-- The length of the ‘value’ is specified by the definition of the object.
-- (e.g. if an object is defined as INTEGER (1..65535), it must always be
-- stored using two octets). There must always be that number of octets
-- used to store this parameter (even if the value can be represeneted
-- in less octets).
-- A multi-occurrence object may have more than one instance
-- of the defined parameter in the PVR structure. This encoding shall always
-- start with a single octet to specify the number of occurrences for
-- this parameter (cannot exceed 255 occurrences of any parameter).
-- The multiple occurrences for this parameter must
-- be stored sequentially (e.g. if axle spacings then axsp1, axsp2, axsp3 …).
-- The length of each value is specified in the definition of the object
--   and all occurrences of this parameter must be the same length.
--   The number of occurrences octet may be set to 0 to indicate that
--   there are no parameters of this type stored. This encoding allows
--   Pvr Record 1 to specify 5 axle weights for a truck and Pvr Record 2
--   to only specify 2 axle weights for a car. The encoding becomes:
--   [(# of occurrences=n)(value 1)(value 2)…(value n)].

-- For either single or multi-occurrence objects, if the specified object
-- is an integer, the value field shall only consist of the data without
-- a tag or length field as defined in BER encoding. If the specified
-- object is an octet string, it shall be stored with a tag and length field
-- as defined by BER encoding for octet strings. A BER “NULL” may be
-- used in place of any octet string object that could not be determined
-- by the device. This allows for specifying multiple instances of octet
-- strings of varying sizes. A “NULL” is used as opposed to specifying
-- an OCTET STRING of size 0 octets because an OCTET STRING of size 0
-- octets may be a valid value for the specified parameter.

2.3.1     Maximum Number Of Vehicle Criteria Table Rows
dcmVCTMaxNumRows OBJECT-TYPE
 SYNTAX DcmMaxNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the maximum number of rows allowed            for   the   Vehicle   Criteria
Table."
::= {dcmVehCriteria 1}

2.3.2     Current Number Of Vehicle Criteria Table Rows
dcmVCTCurNumRows OBJECT-TYPE
 SYNTAX DcmCurNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the current number of rows existing           in    the   Vehicle   Criteria
Table."



                                                                                          

                                                                                     
                                                                                    



::= {dcmVehCriteria 2}

2.3.3     Vehicle Criteria Table
dcmVehCriteriaTable OBJECT-TYPE
 SYNTAX   SEQUENCE OF DcmVehCriteriaEntry
 ACCESS   not-accessible
 STATUS   optional
 DESCRIPTION
 "This is a single-indexed table. It contains all the OID’s (from this MIB
and also can contain OID’s from other MIBS) of all objects that this dcm
device shall support for vehicle criteria to be used in configuring binned
studies, pvr studies and filters."
::= {dcmVehCriteria 3}

dcmVehCriteriaEntry OBJECT-TYPE
 SYNTAX   DcmVehCriteriaEntry
 ACCESS   not-accessible
 STATUS   mandatory
 DESCRIPTION "..."
 INDEX {dcmVCIndex}
::= {dcmVehCriteriaTable 1}

DcmVehCriteriaEntry ::= SEQUENCE
{
 dcmVCIndex    INTEGER,
 dcmVCOID      OBJECT IDENTIFIER,
 dcmVCBitMap   INTEGER
}

2.3.3.1    Vehicle Criteria Index
dcmVCIndex OBJECT-TYPE
 SYNTAX INTEGER (1..255)
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the only index into this table. It represents a unique sequential
number for each row in this table."
::= {dcmVehCriteriaEntry 1}

2.3.3.2    Vehicle Criteria OID
dcmVCOID OBJECT-TYPE
 SYNTAX   OBJECT IDENTIFIER
 ACCESS   read-only
 STATUS   mandatory
 DESCRIPTION
 "This field contains the OID of a Vehicle Criteria object that is supported
by this device. The OID specified must be a full OID from the root of the iso
tree, relative OID’s cannot be used. This allows referring to objects outside
of this MIB. The specified OID can also be an OID from a table (if the object
is only defined within a table (e.g. Array Number), but it shall be the OID of
the object from the table in which the specified object is defined (e.g. if
Array Number is to be used, the OID shall be taken from the Logical IO To
Array Map Table"
::= {dcmVehCriteriaEntry 2}

2.3.3.3    Vehicle Criteria Support BitMap
dcmVCBitMap OBJECT-TYPE


                                                                                        

                      
       



 SYNTAX INTEGER (0..255) --Bitmap
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "This bitmap indicates which set of functionality for each specified OID
(dcmVCOID) this device supports. Setting a bit to one (1) indicates that the
associated functionality is supported. All unused bits shall be reserved.
Note that the options pvrStudySingle and pvrStudyMulti are included to
specifically address any objects that are supported by the device for PVR
Studies, but do not specify if it is a single-occurrence or multi-occurrence
object in it’s definition.
The values are:
bit 0 – other
bit 1 – binnedStudy, the object specified by dcmVCOID is supported to
configure binned studies.
bit 2 – pvrStudySingle, the object specified by dcmVCOID is supported to
configure pvr studies and is a single-occurrence object. Note that both
pvrStudySingle and pvrStudyMulti cannot be selected for the same object. Only
one of the two options may be selected for the specified object.
bit 3 – pvrStudyMulti, the object specified by dcmVCOID is supported to
configure pvr studies and is a multi-occurrence object.        Note that both
pvrStudySingle and pvrStudyMulti cannot be selected for the same object. Only
one of the two options may be selected for the specified object.
bit 4 – filters, the object specified by dcmVCOID is supported to configure
filters."
::= {dcmVehCriteriaEntry 3}

2.3.4     Axle Number
dcmAxleNumber OBJECT-TYPE
 SYNTAX INTEGER (1..255)
 ACCESS not-accessible
 STATUS optional
 DESCRIPTION
 "Indicates the axle number of a vehicle that is being referenced. This is a
discrete number and has no units. A value of one (1) indicates the first axle
of a vehicle detected by the sensor array. The highest value that this object
can reference is defined by the value of the dcmMaxNumAxles object."
::= {dcmVehCriteria 4}

2.3.5     Number of Axles
dcmNumAxles OBJECT-TYPE
 SYNTAX INTEGER (0..255)
 ACCESS not-accessible
 STATUS optional
 DESCRIPTION
 " Indicates the number of axles on a vehicle. This is a discrete number and
has no units. A value of zero (0) indicates that no axles were detected. The
highest value that this object can reference is defined by the value of the
dcmMaxNumAxles object."
::= {dcmVehCriteria 5}

2.3.6     Vehicle Class
dcmVehicleClass OBJECT-TYPE
 SYNTAX INTEGER (0..255)
 ACCESS not-accessible
 STATUS optional
 DESCRIPTION



                                                                                 

                                                                                     
                                                                                    



 "Indicates a system-wide unique classification of a vehicle. Any or all
vehicle parameters (such as vehicle length, axle spacings,…) can be used to
derive this classification. This is a discrete number and has no units."
::= {dcmVehCriteria 6}

2.3.7     Vehicle Speed
dcmVehicleSpeed OBJECT-TYPE
 SYNTAX INTEGER (0..65535)
 ACCESS not-accessible
 STATUS optional
 DESCRIPTION
 "Indicates the vehicle speed, in cm/sec."
::= {dcmVehCriteria 7}

2.3.8     Vehicle Length
dcmVehicleLength OBJECT-TYPE
 SYNTAX INTEGER (0..65535)
 ACCESS not-accessible
 STATUS optional
 DESCRIPTION
 "Indicates the overall length of a vehicle, in cm, from the physical start to
the physical end of the vehicle."
::= {dcmVehCriteria 8}

2.3.9     Vehicle Front Overhang
dcmFrontOverhang OBJECT-TYPE
 SYNTAX INTEGER (0..65535)
 ACCESS not-accessible
 STATUS optional
 DESCRIPTION
 "Indicates the front overhang of a vehicle which is measured from                 the
physical start of a vehicle to its first axle (center), units are cm."
::= {dcmVehCriteria 9}

2.3.10    Vehicle Rear Overhang
dcmRearOverhang OBJECT-TYPE
 SYNTAX INTEGER (0..65535)
 ACCESS not-accessible
 STATUS optional
 DESCRIPTION
"Indicates the rear overhang of a vehicle which is measured              from     last
axle(center) of a vehicle to it the physical end, units are cm."
::= {dcmVehCriteria 10}

2.3.11    Axle Spacing
dcmAxleSpacing OBJECT-TYPE
 SYNTAX INTEGER (0..65535)
 ACCESS not-accessible
 STATUS optional
 DESCRIPTION
 "Indicates the spacing between adjacent axles (from the center of one axle to
the center of the next axle), measured in cm. This is a multiple-occurrence
object where the number of occurrences is one less than the number of axles
detected for this vehicle.
A value of zero (0) shall be recorded for any axle spacings that cannot be
determined."



                                                                                        

                      
       



::= {dcmVehCriteria 11}

2.3.12    Vehicle Wheelbase
dcmVehWheelbase OBJECT-TYPE
 SYNTAX INTEGER (0..65535)
 ACCESS not-accessible
 STATUS optional
 DESCRIPTION
 "Indicates the distance from the first to the last axle (center to center) of
a vehicle. Units are cm.
A value of zero (0) shall be recorded if the vehicle wheelbase cannot be
determined."
::= {dcmVehCriteria 12}

2.3.13    Vehicle Clearance
dcmVehClearance OBJECT-TYPE
 SYNTAX INTEGER (0..255)
 ACCESS not-accessible
 STATUS optional
 DESCRIPTION
 "Indicates the clearance of the vehicle above ground measured from the lowest
point of the vehicle excluding tire and wheel, in cm.
A value of zero (0) shall be recorded if the vehicle clearance cannot be
determined."
::= {dcmVehCriteria 13}

2.3.14    Vehicle Height
dcmVehicleHeight OBJECT-TYPE
 SYNTAX INTEGER (0..65535)
 ACCESS not-accessible
 STATUS optional
 DESCRIPTION
 "Indicates the overall height of the vehicle from the ground to its highest
point including load, measured in cm.
A value of zero (0) shall be recorded if the vehicle height cannot be
determined."
::= {dcmVehCriteria 14}

2.3.15    Axle Width
dcmAxleWidth OBJECT-TYPE
 SYNTAX INTEGER (0..65535)
 ACCESS not-accessible
 STATUS optional
 DESCRIPTION
 "Indicates the overall width of an axle from outside edge to outside edge of
the outer tires on a vehicle, measured in cm. This is a multiple occurrence
object where the number of occurrences is equal to the number of axles
detected for this vehicle.
A value of zero (0) shall be recorded for any axle widths that cannot be
determined."
::= {dcmVehCriteria 15}

2.3.16    Vehicle Width
dcmVehicleWidth OBJECT-TYPE
 SYNTAX INTEGER (0..65535)
 ACCESS not-accessible



                                                                                  

                                                                                     
                                                                                    



 STATUS optional
 DESCRIPTION
 "Indicates the width of the vehicle at the widest point including load. Units
are cm.
A value of zero (0) shall be recorded if the vehicle width cannot be
determined."
::= {dcmVehCriteria 16}

2.3.17    Axle Tire Count
dcmAxleTireCount OBJECT-TYPE
 SYNTAX INTEGER (0..255)
 ACCESS not-accessible
 STATUS optional
 DESCRIPTION
 "Indicates the total number of tires per axle.       Note that for dual-tire
axles, this value shall be 4.
This is a multiple occurrence object where the number of occurrences is equal
to the number of axles detected for this vehicle.
A value of zero (0) shall be recorded for any tire counts per axle that cannot
be determined."
::= {dcmVehCriteria 17}

2.3.18    Axle Tire Track
dcmAxleTireTrack OBJECT-TYPE
 SYNTAX INTEGER (0..65535)
 ACCESS not-accessible
 STATUS optional
 DESCRIPTION
 "Indicates the distance from the right-most edge of the sensor array to the
right-most tire per axle. Units are in cm.
This is a multiple occurrence object where the number of occurrences is equal
to the number of axles detected for this vehicle.
A value of zero (0) shall be recorded for any axle tire track that cannot be
determined."
::= {dcmVehCriteria 18}

2.3.19    Vehicle Gap
dcmVehicleGap OBJECT-TYPE
 SYNTAX INTEGER (0..16711425)
 ACCESS not-accessible
 STATUS optional
 DESCRIPTION
 "Indicates the time separation between 2 vehicles, measured in milliseconds.
This value is measured from the physical end of the preceding vehicle to the
physical start of the current vehicle. A value of zero (0) is used where the
gap cannot be determined. If the detected value exceeds the maximum value of
this object, the maximum value shall be used."
::= {dcmVehCriteria 19}

2.3.20    Vehicle Headway
dcmVehicleHeadway OBJECT-TYPE
 SYNTAX INTEGER (0..1671142)
 ACCESS not-accessible
 STATUS optional
 DESCRIPTION
 "Indicates the time separation between 2 vehicles, measured in milliseconds.
This value is measured from the physical start of the preceding vehicle to the


                                                                                        

                      
       



physical start of the current vehicle. A value of zero (0) is used where the
gap cannot be determined. If the detected value exceeds the maximum value of
this object, the maximum value shall be used."
::= {dcmVehCriteria 20}

2.3.21    Left Wheel Weight
dcmLeftWheelWeight OBJECT-TYPE
 SYNTAX INTEGER (0..65535)
 ACCESS not-accessible
 STATUS optional
 DESCRIPTION
 "Indicates the weight of the left wheel (left group of one or more tires on
the same axle relative to the direction of travel), measured in kilograms.
This is a multiple occurrence object where the number of occurrences is equal
to the number of axles detected for this vehicle.
A value of zero (0) shall be recorded for any axle wheel weights that cannot
be determined."
::= {dcmVehCriteria 21}

2.3.22    Right Wheel Weight
dcmRightWheelWeight OBJECT-TYPE
 SYNTAX INTEGER (0..65535)
 ACCESS not-accessible
 STATUS optional
 DESCRIPTION
 "Indicates the weight of the right wheel (right group of one or more tires on
the same axle relative to the direction of travel), measured in kilograms.
This is a multiple occurrence object where the number of occurrences is equal
to the number of axles detected for this vehicle.
A value of zero (0) shall be recorded for any axle wheel weights that cannot
be determined."
::= {dcmVehCriteria 22}

2.3.23    Axle Weight
dcmAxleWeight OBJECT-TYPE
 SYNTAX INTEGER (0..65535)
 ACCESS not-accessible
 STATUS optional
 DESCRIPTION
 "Indicates the weight of an axle, measured in kilograms.
This is a multiple occurrence object where the number of occurrences is equal
to the number of axles detected for this vehicle.
A value of zero (0) shall be recorded for any axle weights that cannot be
determined."
::= {dcmVehCriteria 23}

2.3.24    Sensor Weights
dcmSensorWeight OBJECT-TYPE
 SYNTAX INTEGER (0..65535)
 ACCESS not-accessible
 STATUS optional
 DESCRIPTION
 "Indicates the weight calculated by a WIM sensor, measured in kilograms.
This is a multiple occurrence object where the number of occurrences is equal
to the number of axles detected for this vehicle multiplied by the number of
WIM sensors in the array. The number of WIM sensors in the array is defined in
the logicalIoArrayMappingTable.   The sequence of sensorWeight values within


                                                                                  

                                                                                     
                                                                                    



the data collection file is logicalIoNumber value and then axleNumber value
(e.g., a 3-axle vehicle crosses a 2-sensor WIM array, it would be recorded as
logicalIoNumber1-axleNumber1-sensorWeight value, logicalIoNumber1-axleNumber2-
sensorWeight    value,     logicalIoNumber1-axleNumber3-sensorWeight    value,
logicalIoNumber2-axleNumber1-sensorWeight value, logicalIoNumber2-axleNumber2-
sensorWeight value, logicalIoNumber2-axleNumber3-sensorWeight value). The WIM
logicalIoNumbers shall be listed in ascending order.
A value of zero (0) shall be recorded for any sensor weights that cannot be
determined."
::= {dcmVehCriteria 24}

2.3.25    Gross Vehicle Weight
dcmGrossVehicleWeight OBJECT-TYPE
 SYNTAX INTEGER (0..16711425)
 ACCESS not-accessible
 STATUS optional
 DESCRIPTION
 "Indicates the gross weight of a vehicle (the sum of all axle weights),
measured in kilograms. A value of zero (0) shall be recorded, if the gross
vehicle weight cannot be determined."
::= {dcmVehCriteria 25}

2.3.26    Vehicle Sequence Number
dcmVehicleSeqNum OBJECT-TYPE
 SYNTAX INTEGER (0..65535)
 ACCESS not-accessible
 STATUS optional
 DESCRIPTION
 "A number assigned to each vehicle that traverses a sensor array.         The
numbers are assigned sequentially over all sensor arrays. The value shall roll
over to a value of 1 (1-65535). If a sequential number cannot be assigned, a
value of zero (0) shall be used.          This number along with a time tag
(controller-localTime) is used to uniquely identify vehicles. For example, if
a vehicle traverses sensor array 1 and is assigned sequence number 1, the next
vehicle (regardless of which sensor array it traverses will be assigned
sequence number 2."
::= {dcmVehCriteria 26}

2.3.27    Vehicle Status Flag
dcmVehicleStatusFlag OBJECT-TYPE
 SYNTAX INTEGER (0..4294967295) --Bitmap
 ACCESS not-accessible
 STATUS optional
 DESCRIPTION
 "Indicates a vehicle-specific status and warning information (e.g. unbalanced
axle hits) for the specified vehicle. Setting a bit to one (1) indicates that
the associated condition is true. The values are:
bit 0 – other
bit 1 – off/onScale – physical off scale sensor is triggered or the on scale
sensor was NOT triggered.
bit 2 – overHeight – physical overheight sensor was triggered
bit 3 – speedChange – too much speed change detected between adjacent axles
for this vehicle
bit 4 – partialAxle – something went wrong in the middle of processing an axle
bit 5 – unequalAxleCount – number of axles detected on each axle sensor is not
the same.
bit 6 – tailgating – this vehicle follows the preceding vehicle too closely



                                                                                        

                      
       



bit 7 – wrongLane – this vehicle is in the wrong lane
bit 8 – runningScale – this vehicle bypassed the weigh-station incorrectly
bit 9 – notWimLane – this class of vehicle should not be in this lane
bit 10 – overlength – vehicle exceeds length threshold
bit 11 – overGVW – vehicle exceeds GVW weight threshold
bit 12 – randomSafety – vehicle randomly selected for Safety check
bit 13 – overSpeed - vehicle exceeds the speed threshold
bit 14 – late – vehicle arrives late at the next sensor array; used in
conjunction with bits 18, 19, 20.
bit 15 – unexpected – vehicle arrives unexpectedly at the next sensor array
bit 16 – pastDue – vehicle didn’t arrive at the next sensor array within the
arrival threshold
bit 17 – noMatch – no vehicle match was found for this vehicle at this sensor
array
bit 18 – badLateralPosition – error computing vehicle position (tire tracking)
bit 19 – noCompliance – no vehicle compliance structure found for this class
of vehicle
bit 20 – overrideFail – failed to adjust the direction signs in time
bit 21 – wrongWay – vehicle went over the sensor array in an unexpected
direction
bit 22- MinSpeed – too slow for data processing purposes
bit 23 – AxleProcessingError – internal error inside the vehicle processing
software
bit 24 - MaxSpeed – too fast for data processing purposes
bit 25 - TooManyAxles – the value indicated in the dcmMaxAxles object has been
exceeded
bit 26 - SensorOrderError – at least one of the sensors within the array was
not activated in the expected order, e.g., only the upstream sensor, or only
the downstream sensor was activated, or a sensor was activated by another lane
movement
bit 27 – MinAxleSpacing – the detected value for the axle spacing was below
the threshold for minAxleSpacing
bit 28 – MinFirstAxleSpacing - the detected value for the first axle spacing
was below the threshold for minFirstAxleSpacing
All unused bits are reserved."
::= {dcmVehCriteria 27}

2.3.28    Axle Weight Violation Code
dcmAxleWeightViolationCode OBJECT-TYPE
 SYNTAX INTEGER (0..16711425) -- bitmap
 ACCESS not-accessible
 STATUS optional
 DESCRIPTION
 "Indicates axle-specific violations (e.g., axle overweight) for the specified
vehicle. Setting a bit to one (1) indicates that the associated condition is
true. This object is a bitmap.
The bit assignments are:
OtherWeightViolation (bit 0) – if a weight violation not defined below has
been detected.
SteeringViolation (bit 1) – if the allowable steering axle weight has been
exceeded and if this axle is part of a steering axle group.
SingleAxleViolation (bit 2) – if the allowable single axle weight has been
exceeded and if this axle is a single axle.
TandemAxleViolation (bit 3) - if the allowable tandem axle weight has been
exceeded and if this axle is part of a tandem axle group.
TridemAxleViolation (bit 4) - if the allowable tridem axle weight has been
exceeded and if this axle is part of a tridem axle group.




                                                                                  

                                                                                     
                                                                                    



QuadremAxleViolation (bit 5) - if the allowable quadrem axle weight has been
exceeded and if this axle is part of a quadrem axle group.
AxleBalanceViolation (bit 6) – if the difference between axle weights within
an axle group exceeds a pre-defined threshold.
AxleGroupIndividualViolation (bit 7) – if the maximum weight ‘individual axle’
threshold for an individual axle within an axle group has been exceeded.
BridgeViolation (bit 8) –if this axle is part of any combination of axles
which exceed the maximum bridge weight threshold.
WheelViolation (bit 9) - if the allowable wheel weight for any single wheel
(group of tires) on an axle has been exceeded.
WheelImbalanceViolation (bit 10) – if the imbalance between wheel weights on
an axle exceeds a pre-defined threshold.
The definition of what constitutes a violation is NOT defined by this
standard. If a violation has been detected the corresponding bit shall be set
to 1. Thus, if no violation has been detected, the value of this object is
zero (0).
This object is a multiple-occurrence object where the number of occurrences is
equal to the number of axles detected for this vehicle.
All unused bits are reserved."
::= {dcmVehCriteria 28}

2.3.29    Vehicle Acceleration
dcmVehicleAcceleration OBJECT-TYPE
 SYNTAX INTEGER (-32768..32767)
 ACCESS not-accessible
 STATUS optional
 DESCRIPTION
 "Indicates the acceleration/deceleration of a vehicle, measured in cm/s².
Deceleration is defined as negative acceleration. A value of -32768 shall be
recorded, if the acceleration of a vehicle cannot be determined."
::= {dcmVehCriteria 29}


2.3.30    Number of Vehicle IDs
dcmNumVehicleIDs OBJECT-TYPE
 SYNTAX INTEGER (0..255)
 ACCESS not-accessible
 STATUS optional
 DESCRIPTION
 "Indicates the total number of vehicle IDs associated with a vehicle."
::= {dcmVehCriteria 30}

2.3.31    Vehicle ID
dcmVehicleID OBJECT-TYPE
 SYNTAX OCTET STRING
 ACCESS not-accessible
 STATUS optional
 DESCRIPTION
 "Indicates a vehicle ID, typically read from the vehicle using an AVI
(Automatic Vehicle Identification) device such as a tag. This object can only
be used in the PVR Study Configuration Table. Since it is not an Integer, it
cannot be used in the Filter Configuration Table.
This is a multiple-occurrence object where the number of occurrences is equal
to the number of vehicle ID’s associated with this vehicle.
A NULL shall be recorded for any vehicle IDs that cannot be determined.
When this object is used in a PVR study, the value shall be stored using BER
encoding (TLV) since it is an Octet String."



                                                                                        

                      
       



::= {dcmVehCriteria 31}

2.3.32    Vehicle Time Tag in 1000th Seconds
dcmVehicleTimeTag1000 OBJECT-TYPE
 SYNTAX INTEGER (0..999)
 ACCESS not-accessible
 STATUS optional
 DESCRIPTION
 "The time expressed in 1000th of a second (milliseconds). This object is only
used when a higher resolution than 1 sec is required for a vehicle time tag.
This value is used in conjunction with the ‘controller-localTime’ object in
that this counter rolls over every second. The DCM device shall record this
value with its highest resolution which may be less than 100th of a second."
::= {dcmVehCriteria 32}


2.4     DEVICE SETUP NODE

--DCM Device Setup Node
dcmDeviceSetup OBJECT IDENTIFIER ::= {dcm 2}
-- This node is an identifier used to group all objects for configuring of the
-- device setup parameters that are common to data collection and monitoring
-- devices.

2.4.1     Unique Device ID
dcmDeviceId OBJECT-TYPE
 SYNTAX OCTET STRING (SIZE (0..16))
 ACCESS read-write
 STATUS optional
 DESCRIPTION
 "Indicates a user-assigned unique          number or string of characters that
identifies the overall DCM device.           This is not to be confused with the
dcmSiteID object value."
::= {dcmDeviceSetup 1}

2.4.2     Battery Voltage
dcmBatteryVoltage OBJECT-TYPE
 SYNTAX INTEGER (0..255)
 ACCESS read-only
 STATUS optional
 DESCRIPTION
 "Indicates the voltage of the battery at the time of the request. The value
range shall be 00.0-25.5V in 0.1 increments."
::= {dcmDeviceSetup 2}

2.4.3     Charging Current
dcmChargingCurrent OBJECT-TYPE
 SYNTAX INTEGER(-100000..100000)
 ACCESS read-only
 STATUS optional
 DESCRIPTION
 "Indicates the charging current in milliAmperes at the time of the request.
The value range shall be +/- 100000 mA in 1 mA increments."
::= {dcmDeviceSetup 3}

2.4.4         Current Number Of IO Boards


                                                                                      

                                                                                        
                                                                                       



dcmNumIoBoards OBJECT-TYPE
 SYNTAX INTEGER(0..255)
 ACCESS read-only
 STATUS optional
 DESCRIPTION
 "Indicates   the   current   number    of   IO   Boards    configured         in     the
dcmIOBoardConfigTable."
::= {dcmDeviceSetup 4}

2.4.5     Maximum Number Of IO Board Configuration Table Rows
dcmIOBCTMaxNumRows OBJECT-TYPE
 SYNTAX DcmMaxNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the maximum number of rows allowed for the IO Board Configuration
Table."
::= {dcmDeviceSetup 5}

2.4.6     Current Number Of IO Board Configuration Table Rows
dcmIOBCTCurNumRows OBJECT-TYPE
 SYNTAX DcmCurNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the current number of rows existing in the IO Board Config Table."
::= {dcmDeviceSetup 6}

2.4.7     IO Board Configuration Table
dcmIOBoardConfigTable OBJECT-TYPE
 SYNTAX    SEQUENCE OF DcmIOBoardConfigEntry
 ACCESS    not-accessible
 STATUS    optional
 DESCRIPTION
 "This table defines the configuration parameters for each IO Board installed
in the DCM device. Rows are created/deleted only through the insertion or
removal of boards within the device.     There may be one or more entries for
each IO board in the device (e.g. a single IO board may support multiple
functions such as cpu and storageMedia). This is a double-indexed table."
::= {dcmDeviceSetup 7}

dcmIOBoardConfigEntry OBJECT-TYPE
 SYNTAX   DcmIOBoardConfigEntry
 ACCESS   not-accessible
 STATUS   mandatory
 DESCRIPTION "..."
 INDEX    {dcmIOBCBoardNum, dcmIOBoardFunction}
::= {dcmIOBoardConfigTable 1}

DcmIOBoardConfigEntry ::= SEQUENCE
{
 dcmIOBCBoardNum       DcmIOBoardNum,
 dcmIOBoardFunction    DcmIOBoardFtn,
 dcmIOBCNumIO          INTEGER,
 dcmIOBoardType        INTEGER,
 dcmIOBoardDescription OCTET STRING,
 dcmIOBoardStatus      INTEGER,



                                                                                           

                      
       



 dcmIOBoardControl                 INTEGER
}

2.4.7.1    IO Board Number
dcmIOBCBoardNum OBJECT-TYPE
 SYNTAX   DcmIOBoardNum
 ACCESS   read-only
 STATUS   mandatory
 DESCRIPTION
 "Indicates the first index into this table. It represents a unique number
for each IO Board that has been installed within the device. This index is
assigned by the device and must be sequential."
::= {dcmIOBoardConfigEntry 1}

2.4.7.2    IO Board Function
dcmIOBoardFunction OBJECT-TYPE
 SYNTAX   DcmIOBoardFtn
 ACCESS   read-only
 STATUS   mandatory
 DESCRIPTION
 "Since an IO board can have multiple functions, this index allows the
capability to define multiple IO Board Function Types for the same board. For
instance a CPU board might have roadtube inputs and storage media available.
Although the IO Board Function Type could be used for the 2nd index, it would
probably end up in a table that had non-sequential indexes. This secondary
index is assigned by the device and must be sequential."
::= {dcmIOBoardConfigEntry 2}

2.4.7.3    IO Board Number Of IO
dcmIOBCNumIO OBJECT-TYPE
 SYNTAX   INTEGER (1..255)
 ACCESS   read-only
 STATUS   mandatory
 DESCRIPTION
 "This is the number of IO’s of the type specified by IO Board Function Type
for this board number specified by IO Board # in this row."
::= {dcmIOBoardConfigEntry 3}

2.4.7.4     IO Board Function Type
dcmIOBoardType OBJECT-TYPE
 SYNTAX INTEGER
 {
   other (1),
   cpu (2),
   storageMedia (3),
   inputNonSensor (4),
   output (5),
   comms (6),
   keyboard (7),
   display (8),
   roadTube (9),
   piezo (10),
   loop (11),
   wimPiezo (12),
   bendingPlate (13),
   contactClosure (14),
   acoustic (15),


                                                                                 

                                                                                     
                                                                                    



  radar (16),
  microwave (17),
  infrared (18),
  laser (19),
  optoIsolated (20),
  fiberOptic (21),
  contactRelay (22),
  quartz (23),
  lightcurtain (24),
  video (25),
  timer (26),
  fiberOpticWim (27),
  ultrasound (28)
 }
 ACCESS   read-only
 STATUS   mandatory
 DESCRIPTION
 "Indicates the main functional type of this IO board. The values are:
other – not defined below
cpu – main processor
storageMedia – board provides data storage area (e.g. FLASH, SRAM, Hard
Disk,…)
inputNonSensor – board provides input from a non-sensor (e.g. contact input
controlled by an external software application)
output – board provides output functionality (e.g. solid state relay)
comms – board provides communications functionality (e.g. rs232, Ethernet,…)
keyboard - board provides key inputs
display – board provides display capability (e.g. LCD…)
roadTube – IO sensor
piezo – IO sensor
loop – IO sensor
wimPiezo – IO sensor
bendingPlate – IO sensor
contactClosure – IO sensor
acoustic – IO sensor
radar – IO sensor
microwave – IO sensor
infrared – IO sensor
laser – IO sensor
optoIsolated – IO sensor
fiberOptic – IO sensor
contactRelay – IO sensor
quartz – IO sensor
lightcurtain – IO sensor
video – IO sensor
timer – IO sensor
fiberOpticWim – IO sensor
ultrasound – IO sensor"
::= {dcmIOBoardConfigEntry 4}

2.4.7.5    IO Board Description
dcmIOBoardDescription OBJECT-TYPE
 SYNTAX   OCTET STRING
 ACCESS   read-only
 STATUS   optional
 DESCRIPTION
 "Indicates a device-provided description of the board. It is suggested that
this string contain information such as board slot/address in device, firmware



                                                                                        

                      
       



version, hardware version, model #, serial #, vendor name, # of IO ports on
this board, storage media type (sram, flash,…), storage media size. Note that
all listed information may not be applicable to each type of IO board. This
object is only used to identify more information regarding the IO board. It is
not used to configure the board. Some of the information in this object may
be dynamic."
::= {dcmIOBoardConfigEntry 5}

2.4.7.6     IO Board Status
dcmIOBoardStatus OBJECT-TYPE
 SYNTAX INTEGER
 {
   enabled (1),
   disabled (2),
   fault (3),
   resetting (4),
   suspended (5)
 }
 ACCESS    read-only
 STATUS    mandatory
 DESCRIPTION
 "indicates whether this IO Board is currently active. The values are:
enabled (1) – the board is required for the current study configuration and is
in use.
disabled (2) – the board is required for the current study configuration but
has been disabled.
fault (3), - At least one of the IO channels on this board is in fault. The
dcmPhysicalLogicalMapTable can be interrogated to determine which specific
channels are in fault.
resetting (4) – this indicates that the IO board is currently being reset.
After the reset has completed, it shall be modified to (enabled), (suspended)
or (fault).
suspended (5) - the board has been disabled by the device because it is not
required for the current study configuration."
::= {dcmIOBoardConfigEntry 6}

2.4.7.7     IO Board Control
dcmIOBoardControl OBJECT-TYPE
 SYNTAX INTEGER
 {
   notSupported (1),
   enable (2),
   disable (3),
   reset (4),
   suspend (5)
 }
 ACCESS    read-write
 STATUS    mandatory
 DESCRIPTION
 "Allows a user to enable, disable, reset, or suspend this IO Board. The value
of this object represents the last user-selected control. If this board is
disabled or enabled, then any entry in the dcmPhysicalLogicalMapTable which
corresponds to this board shall set the IO Status Entry in that table
appropriately. For example, a user may want to temporarily disable a sensor
board to make it easier to debug which sensor inputs may be causing problems
in the field. If the requested operation is not supported by the specified IO
board, this field shal be set to ‘notSupported’.     Performing a reset of a
storage media shall result in the formatting of that media."


                                                                                  

                                                                                    
                                                                                   



::= {dcmIOBoardConfigEntry 7}

2.4.8     Maximum Number Of Physical To Logical Mapping Table Rows
dcmPLMTMaxNumRows OBJECT-TYPE
 SYNTAX DcmMaxNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the maximum number of rows allowed for the Physical To Logical
Mapping Table."
::= {dcmDeviceSetup 8}

2.4.9     Current Number Of Physical To Logical Table Rows
dcmPLMTCurNumRows OBJECT-TYPE
 SYNTAX DcmCurNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the current number of rows existing in the Physical To Logical
Table."
::= {dcmDeviceSetup 9}

2.4.10    Physical to Logical Mapping Table
dcmPhysicalLogicalMapTable OBJECT-TYPE
 SYNTAX SEQUENCE OF DcmPhysicalLogicalMapEntry
 ACCESS   not-accessible
 STATUS   optional
 DESCRIPTION
 "This table maps a physical IO to a unique logical IO number. The logical IO
number will then be used as a reference by the other objects/tables within
this mib to manipulate the physical IO. This is a double-indexed table."
::= {dcmDeviceSetup 10}

dcmPhysicalLogicalMapEntry OBJECT-TYPE
 SYNTAX   DcmPhysicalLogicalMapEntry
 ACCESS   not-accessible
 STATUS   mandatory
 DESCRIPTION "..."
 INDEX {dcmPLMIOBoardNum, dcmPhysicalIONumber}
::= {dcmPhysicalLogicalMapTable 1}

DcmPhysicalLogicalMapEntry ::= SEQUENCE
{
 dcmPLMIOBoardNum            DcmIOBoardNum,
 dcmPLMIOBoardFunction       DcmIOBoardFtn,
 dcmPhysicalIONumber         INTEGER,
 dcmPLMLogIONum              DcmLogIONum,
 dcmPhysicalLogicalIOStatus INTEGER,
 dcmPhysicalLogicalIOControl INTEGER
}

2.4.10.1   IO Board Number
dcmPLMIOBoardNum OBJECT-TYPE
 SYNTAX   DcmIOBoardNum
 ACCESS   read-only
 STATUS   mandatory
 DESCRIPTION


                                                                                       

                      
       



 "Indicates the first index into this table. Refer to DcmIOBoardNum for a more
detailed description."
::= {dcmPhysicalLogicalMapEntry 1}
2.4.10.2
2.4.10.3   IO Board Function
dcmPLMIOBoardFunction OBJECT-TYPE
 SYNTAX   DcmIOBoardFtn
 ACCESS   read-only
 STATUS   mandatory
 DESCRIPTION
 "Since an IO board can have multiple functions, this index identifies the
function of the IO within the IO Board Number specified by dcmPLMIOBoardNum
for this row."
::= {dcmPhysicalLogicalMapEntry 2}

2.4.10.4   Physical IO Number
dcmPhysicalIONumber OBJECT-TYPE
 SYNTAX   INTEGER (1..255)
 ACCESS   read-only
 STATUS   mandatory
 DESCRIPTION
 "Indicates the second index into this table. This index refers to a channel
within an IO board (e.g. IO board 1 may have 4 inputs which would result in 4
entries in this table to map each of the 4 inputs 1-1, 1-2, 1-3, 1-4). This
index is assigned by the device and must be sequential."
::= {dcmPhysicalLogicalMapEntry 3}

2.4.10.5   Logical IO Number
dcmPLMLogIONum OBJECT-TYPE
 SYNTAX   DcmLogIONum
 ACCESS   read-only
 STATUS   mandatory
 DESCRIPTION
 "See DcmLogIONum description"
::= {dcmPhysicalLogicalMapEntry 4}

2.4.10.6    Physical IO Status
dcmPhysicalLogicalIOStatus OBJECT-TYPE
 SYNTAX INTEGER
 {
   enabled (1),
   disabled (2),
   fault (3),
   resetting (4),
   suspended (5)
 }
 ACCESS    read-only
 STATUS    mandatory
 DESCRIPTION
 "Indicates the current status for this IO channel. The values are:
- enabled (1) – the IO is required by the current study configuration and is
in use.
- disabled (2) – the IO is required for the current study configuration but
has been disabled.
- fault (3), - This IO channel is in fault.




                                                                                  

                                                                                     
                                                                                    



- resetting (4) – this indicates that the IO is currently being reset. After
the reset has completed, it shall be modified to (enabled), (suspended) or
(fault).
- suspended (5) – the IO has been disabled by the device because it is not
required for the current study configuration."
::= {dcmPhysicalLogicalMapEntry 5}

2.4.10.7    Physical IO Control
dcmPhysicalLogicalIOControl OBJECT-TYPE
 SYNTAX    INTEGER
 {
   notSupported (1),
   enable (2),
   disable (3),
   reset (4),
   suspend (5)
 }
 ACCESS    read-write
 STATUS    mandatory
 DESCRIPTION
 "Allows an application to enable, disable,reset or suspend a physical IO
channel. The value of this object represents the last user-selected control.
An application may want to enable/disable an IO channel for diagnostic
purposes.    If the requested operation is not supported by the specified IO
channel, this value shall be set to ‘notSupported’."
::= {dcmPhysicalLogicalMapEntry 6}

2.4.11    Maximum Number Of Logical IO Parmater Table Rows
dcmLIOPTMaxNumRows OBJECT-TYPE
 SYNTAX DcmMaxNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the maximum number of rows allowed for the Logical IO Parameter
Table."
::= {dcmDeviceSetup 11}

2.4.12    Current Number Of Logical IO Parameter Table Rows
dcmLIOPTCurNumRows OBJECT-TYPE
 SYNTAX DcmCurNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the current number of rows existing in the Logical IO Parameter
Table."
::= {dcmDeviceSetup 12}

2.4.13    Logical IO Parameter Table
dcmIOParamTable OBJECT-TYPE
 SYNTAX   SEQUENCE OF DcmIOParamEntry
 ACCESS   not-accessible
 STATUS   optional
 DESCRIPTION
 "This table defines parameters that can be applied to each IO channel to
allow processing and adjustment of that IO channel.      There can be multiple
rows within this table for each logical IO. The indexing of this table will
not be sequential.       If an application tries to define more rows than the


                                                                                        

                      
       



device will allow, an application error code of ‘exceeded max number of rows
allowed’ shall be set.    This is a double-indexed table.    The table can be
managed thru dcmIOParamRowAdmin object.
If an attempt is made to set a parameter of an IO channel and the IO board
associated with the IO channel can only set the parameter at a board level,
all IO channels of that type (which have been entered into this table) on that
IO board will be set to the specified value. It is up to the application to
re-read this table to determine if any of the requested parameters have been
changed.

Conversely, if it is possible to access each IO channel within a board then
each IO channel has to be set individually. Note that all IO channels may not
require any parameters set and some IO channels may require multiple
parameters set."
::= {dcmDeviceSetup 13}

dcmIOParamEntry OBJECT-TYPE
 SYNTAX   DcmIOParamEntry
 ACCESS   not-accessible
 STATUS   mandatory
 DESCRIPTION "..."
 INDEX   {dcmIOPNum, dcmIOPTyp}
::= {dcmIOParamTable 1}

DcmIOParamEntry ::= SEQUENCE
{
 dcmIOPNum          DcmLogIONum,
 dcmIOPTyp          DcmIOParamType,
 dcmIOPVal          DcmIOParamValue,
 dcmIOParamRowAdmin DcmRowStatus
}

2.4.13.1   IO Parameter Logical IO Number
dcmIOPNum OBJECT-TYPE
 SYNTAX   DcmLogIONum
 ACCESS   read-only
 STATUS   mandatory
 DESCRIPTION
 "First index into this table.              Refer   to   DcmLogIONum    for   detailed
description."
::= {dcmIOParamEntry 1}
2.4.13.2
2.4.13.3   IO Parameter Type
dcmIOPTyp OBJECT-TYPE
 SYNTAX DcmIOParamType
 ACCESS   read-only
 STATUS   mandatory
 DESCRIPTION
 "Indicates the second index into this table. A second index is required to
allow assigning multiple parameters for any IO channel. The indexes will most
likely not be assigned sequentially.      If an application tries to set a
parameter on an IO channel that is invalid, an application error of ‘invalid
option’ shall be set."
::= {dcmIOParamEntry 2}

2.4.13.4   IO Parameter Value
dcmIOPVal OBJECT-TYPE


                                                                                        

                                                                                     
                                                                                    



 SYNTAX   DcmIOParamValue
 ACCESS   read-write
 STATUS   mandatory
 DESCRIPTION
 "Indicates the value for the selected IO parameter. Refer to DcmIOParamValue
a detailed description of the allowed values."
::= {dcmIOParamEntry 3}

2.4.13.5   IO Parameter Row Admin
dcmIOParamRowAdmin OBJECT-TYPE
 SYNTAX   DcmRowStatus
 ACCESS   read-write
 STATUS   mandatory
 DESCRIPTION
 "Allows management of the associated ‘logical IO/parameter combination’ (this
row of this table). The SYNTAX definition allows to create, delete, disable,
or edit the row."
::= {dcmIOParamEntry 4}

2.5   OPERATING STATUS CONFIGURATION NODE
--DCM Operating Status Configuration Node
dcmOpsStatus OBJECT IDENTIFIER ::= {dcm 3}
-- This node is an identifier used to group all objects indicating the
-- operating status in ways that are common to data collection and
-- monitoring devices.

-- objects addressing current date and current time are defined in NTCIP 1201
--(plus amendment 1, which are referenced in Annex A.

2.5.1      dcm Resets
dcmReset OBJECT-TYPE
 SYNTAX INTEGER
 {
   other (1),
   hardReset (2),
   softReset (3),
   commReset (4),
   factoryReset (5),
   userReset (6),
   tableClear (7)
 }
 ACCESS read-write
 STATUS optional
 DESCRIPTION
 "indicates the different types of resets that may be issued to the dcm
device. The values and their meaning are:
1=Other
2=Hard Reset
          - (restart program, reset comms, clear all user settings, reset
             sensor boards, reset keyboard/display, reset cpu program memory,
             does not clear data files, resets to all factory defaults, stops
             current recording study)
3=Soft Reset
             - (restart program, does not reset comms, does not change user
                settings, does not reset sensor boards, resets
                keyboard/display, resets cpu program memory, does not clear



                                                                                        

                      
       



                     data files, does not reset to factory defaults, stops    current
                     recording study)
4=Comms Reset
            -        Resets the comms channel used to communicate with the field
                     unit to user defaults.
                 -   It is recommended that all required elements are resynched by
                     the dcm device to ensure that communications is not lost with
                     the dcm unit (e.g. modem).
5=Factory Reset
            - User settings consist of all structures that can be written to.
            - Resets all user settings to factory defaults.
6=User Reset
            - Which objects/tables to reset and the values to reset them to
                is configured by the dcmURCTTable
7=Table Clear
            - The clear operation is based on the dcmTableClearTable
"
::= {dcmOpsStatus 1}

2.5.2     Maximum Number Of Table Clear Table Rows
dcmTCTMaxNumRows OBJECT-TYPE
 SYNTAX DcmMaxNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the maximum number of rows allowed for the Table Clear Table."
::= {dcmOpsStatus 2}

2.5.3     Current Number Of Table Clear Table Rows
dcmTCTCurNumRows OBJECT-TYPE
 SYNTAX DcmCurNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the current number of rows existing in the Table Clear Table."
::= {dcmOpsStatus 3}

2.5.4     Table Clear Table
dcmTableClearTable OBJECT-TYPE
 SYNTAX SEQUENCE OF DcmTableClearEntry
 ACCESS not-accessible
 STATUS optional
 DESCRIPTION
"This table indicates which tables to perform a clear on. Multiple tables or
multiple rows within a table can be specified to be cleared by configuring
multiple rows within this table. The clear can be defined to clear the whole
table or just a row within the table. This is a singly-indexed table.    All
entries must be sequentially indexed.    The OID of this table shall not be
allowed as a valid OID entry in this table."
::= {dcmOpsStatus 4}

dcmTableClearEntry OBJECT-TYPE
 SYNTAX DcmTableClearEntry
 ACCESS not-accessible
 STATUS mandatory
 DESCRIPTION "..."



                                                                                        

                                                                                     
                                                                                    



 INDEX {dcmTableClearIndex}
::={dcmTableClearTable 1}

DcmTableClearEntry ::= SEQUENCE
{
 dcmTableClearIndex INTEGER,
 dcmTCTOID          OBJECT IDENTIFIER,
 dcmTCTAction       INTEGER,
 dcmTCTRowAdmin     DcmRowStatus
}

2.5.4.1    Table Clear Index
dcmTableClearIndex OBJECT-TYPE
 SYNTAX INTEGER (1..255)
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "indicates the only index into this table."
::= {dcmTableClearEntry 1}

2.5.4.2    Table Clear Object Identifier
dcmTCTOID OBJECT-TYPE
 SYNTAX OBJECT IDENTIFIER
 ACCESS read-write
 STATUS mandatory
 DESCRIPTION
 "this value points to the OID of a table. The value of the next object
(dcmTCTAction) then points to the rows that are to be cleared. An error
(noSuchName) shall be returned, if the OID pointed to within this object
instance is not supported by the device."
::= {dcmTableClearEntry 2}

2.5.4.3    Table Clear Action
dcmTCTAction OBJECT-TYPE
 SYNTAX INTEGER (0..255)
 ACCESS read-write
 STATUS mandatory
 DESCRIPTION
 "Setting this to zero (0) shall remove the whole table specified by
dcmTCTOID. Any other value refers to the row number (relative to the first
index of the specified table) to clear. (e.g. if doubly-indexed table, 1-1,1-
2,2-1,2-2, setting this to a 2 would clear out all rows with the first
index=2, 2-1 and 2-2). This action will occur when the dcmReset object is set
to tableClear. If the row or table can not be deleted, then the row or table
shall go to factory default settings. If removing the row or table will
result in an invalid device configuration, the device shall return an error
and not perform the requested action."
::= {dcmTableClearEntry 3}

2.5.4.4    Table Clear Row Admin
dcmTCTRowAdmin OBJECT-TYPE
 SYNTAX   DcmRowStatus
 ACCESS   read-write
 STATUS   mandatory
 DESCRIPTION
 "Allows management of this row of this table.   The SYNTAX definition allows
to create, delete, disable, or edit the row."


                                                                                        

                      
       



::= {dcmTableClearEntry 4}

2.5.5     Current Number Of User Configuration Settings
dcmNumUserConfigs OBJECT-TYPE
 SYNTAX INTEGER(0..255)
 ACCESS read-only
 STATUS optional
 DESCRIPTION
 "Indicates the current number of objects configured for a user reset.
Objects can be configured for a User Reset through the User Reset Config Table
(dcmURCTTable). Note that this is different than the Current Number of User
Reset Config Table Rows object.        For example a user may configure two rows
(two objects) in the User Reset Config Table and then configure 1 more row
(one object) in the User Reset Config Table.            The dcmNumUserConfigs object
will indicate that three objects have been configured for a User Reset, but
the Current Number of User Reset Config Table Rows will only indicate one as
the most recent value (since only one row in the User Reset Config table would
be currently configured)."
::= {dcmOpsStatus 5}

2.5.6     Maximum Number Of User Reset Config Table Rows
dcmURCTMaxNumRows OBJECT-TYPE
 SYNTAX DcmMaxNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the maximum number of rows allowed for the User Reset Config
Table."
::= {dcmOpsStatus 6}

2.5.7     Current Number Of User Reset Config Table Rows
dcmURCTCurNumRows OBJECT-TYPE
 SYNTAX DcmCurNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the current number of rows existing in the User Reset Config
Table."
::= {dcmOpsStatus 7}

2.5.8     User Reset Config Table
dcmURCTTable OBJECT-TYPE
 SYNTAX SEQUENCE OF DcmURCTEntry
 ACCESS not-accessible
 STATUS optional
 DESCRIPTION "Allows a user to define the current settings of an existing
structure to be used as User Default settings for a User Reset.       Multiple
structures can be saved as user defaults by specifying multiple row entries in
this table (or each structure can be saved as a user default one at a time
(only specifying one row in this table)). The OID of this table shall not be
allowed as a valid OID entry in this table. This table has a single index. The
index must be assigned sequentially by the device."
::= {dcmOpsStatus 8}

dcmURCTEntry OBJECT-TYPE
 SYNTAX DcmURCTEntry
 ACCESS not-accessible


                                                                                      

                                                                                     
                                                                                    



 STATUS mandatory
 DESCRIPTION "..."
 INDEX {dcmUserResetConfigIndex}
::={dcmURCTTable 1}

DcmURCTEntry ::= SEQUENCE
{
 dcmUserResetConfigIndex INTEGER,
 dcmURCTOID              OBJECT IDENTIFIER,
 dcmURCTAction           INTEGER,
 dcmURCTRowAdmin         DcmRowStatus
}

2.5.8.1    User Reset Configuration Index
dcmUserResetConfigIndex OBJECT-TYPE
 SYNTAX INTEGER (1..255)
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "indicates the only index into this table."
::= {dcmURCTEntry 1}

2.5.8.2    User Reset Table Object Identifier
dcmURCTOID OBJECT-TYPE
 SYNTAX OBJECT IDENTIFIER
 ACCESS read-write
 STATUS mandatory
 DESCRIPTION
 "this value points to an OID, which may be a leaf OID or a table OID. The
value of the next object (dcmURCTAction) then points to the action that is to
be performed on the referenced OID. An error of (noSuchName) shall be
returned, if the OID pointed to is not supported by the device."
::= {dcmURCTEntry 2}

2.5.8.3     User Reset Config Table Action
dcmURCTAction OBJECT-TYPE
 SYNTAX INTEGER
 {
   clearAllUserDefaults (1),
   clearUserDefsFromOID (2),
   saveUserDefsFromOID (3)
 }
 ACCESS read-write
 STATUS mandatory
 DESCRIPTION
 "Setting this to one (1) shall remove all previously-defined user reset
settings (it ignores the setting of dcmURCTOID).
Setting this to two (2) shall remove only the structure referenced by
dcmURCTOID from the user reset settings defaults.
Setting this to three (3) shall save the current settings of the structure
referenced by dcmURCTOID as a user reset setting default for that structure.

The only way to read what the user settings have been set to is to perform a
User Reset. It is left up to the controlling application to keep track of
what has been configured as User Default Settings. The OID of this table can
be added to the ‘Object Change ID Table’ to allow tracking if the User Default
Settings have been modified."



                                                                                        

                      
       



::= {dcmURCTEntry 3}

2.5.8.4    User Reset Config Row Admin
dcmURCTRowAdmin OBJECT-TYPE
 SYNTAX   DcmRowStatus
 ACCESS   read-write
 STATUS   mandatory
 DESCRIPTION
 "Allows management of this row of this table.   The SYNTAX definition allows
to create, delete, disable, or edit the row."
::= {dcmURCTEntry 4}

2.5.9     Maximum Number Of Object Change ID Table Rows
dcmOCIDTMaxNumRows OBJECT-TYPE
 SYNTAX DcmMaxNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the maximum number of rows allowed for the Object Change ID
Table."
::= {dcmOpsStatus 9}

2.5.10    Current Number Of Object Change ID Table Rows
dcmOCIDTCurNumRows OBJECT-TYPE
 SYNTAX DcmCurNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the current number of rows existing in the Object Change ID
Table."
::= {dcmOpsStatus 10}

2.5.11    Object Change ID Table
dcmOCITable OBJECT-TYPE
 SYNTAX SEQUENCE OF DcmOCIEntry
 ACCESS not-accessible
 STATUS optional
 DESCRIPTION
 "This table allows a user to configure which objects to monitor.      The row
entry is updated by the device if the parameter value of the referenced object
or the value of any of the objects ‘below’ the referenced object node have
changed. It is used to give an external application visibility that some
configuration objects have changed. This table has a single index. The index
must be assigned sequentially by the device."
::= {dcmOpsStatus 11}

dcmOCIEntry OBJECT-TYPE
 SYNTAX   DcmOCIEntry
 ACCESS   not-accessible
 STATUS   mandatory
 DESCRIPTION "..."
 INDEX    {dcmOCIdIndex}
::= {dcmOCITable 1}

DcmOCIEntry ::= SEQUENCE
{
 dcmOCIdIndex     INTEGER,


                                                                                  

                                                                                      
                                                                                     



 dcmOCIdOID            OBJECT IDENTIFIER,
 dcmOCIdTime           Counter,
 dcmOCIdRowAdmin       DcmRowStatus
}

2.5.11.1   Object Change ID Table Index
dcmOCIdIndex OBJECT-TYPE
 SYNTAX INTEGER (1..255)
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the general index into this table.   The values must be assigned
sequentially."
::= {dcmOCIEntry 1}

2.5.11.2   Object Change ID Table OID
dcmOCIdOID OBJECT-TYPE
 SYNTAX OBJECT IDENTIFIER
 ACCESS read-write
 STATUS mandatory
 DESCRIPTION
 "Indicates the Object OID that is being monitored.   The referenced OID can be
any OID supported by the device."
::= {dcmOCIEntry 2}

2.5.11.3   Object Change ID Table Time
dcmOCIdTime OBJECT-TYPE
 SYNTAX Counter
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the timestamp associated with the dcmOCIdIndex (this row).     The
value shows when the change to the reference object/object node occurred. The
setup of this value is the same as defined for the controller-localTime object
as defined in NTCIP 1201."
::= {dcmOCIEntry 3}

2.5.11.4   Object Change ID Row Admin
dcmOCIdRowAdmin OBJECT-TYPE
 SYNTAX   DcmRowStatus
 ACCESS   read-write
 STATUS   mandatory
 DESCRIPTION
 "Allows management of the associated row of this table.                 The    SYNTAX
definition allows to create, delete, disable, or edit the row."
::= {dcmOCIEntry 4}

2.6     SITE SETUP NODE
--DCM Site Setup Node
dcmSiteSetup OBJECT IDENTIFIER ::= {dcm 4}
-- This node is an identifier used to group all objects for configuring
-- a data collection site that are common to data collection and
-- monitoring devices.

2.6.1       Unique Site ID



                                                                                         

                      
       



dcmSiteId OBJECT-TYPE
 SYNTAX OCTET STRING (SIZE (0..40))
 ACCESS read-write
 STATUS optional
 DESCRIPTION
 "Indicates a user-assigned unique number or string of characters that
identifies the location of the DCM device.     Typically, agencies will use
character positions within this field to denote things such as county, city,
lane, direction. This is not to be confused with the unique device ID (see
dcmDeviceID)."
::= {dcmSiteSetup 1}

2.6.2     Maximum Length of Site Description
dcmMaxLengthSiteDescr OBJECT-TYPE
 SYNTAX INTEGER (0..255)
 ACCESS read-only
 STATUS optional
 DESCRIPTION
 "indicates the number of characters that are available within this dcm device
to express the site description."
::= {dcmSiteSetup 2}

2.6.3     Site Description
dcmSiteDescription OBJECT-TYPE
 SYNTAX OCTET STRING
 ACCESS read-write
 STATUS optional
 DESCRIPTION
 " text description of the site at which the dcm device is currently placed."
::= {dcmSiteSetup 3}

2.6.4     Maximum Number of Sensors per Array
dcmMaxSensorsPerArray   OBJECT-TYPE
 SYNTAX INTEGER (0..255)
 ACCESS read-only
 STATUS optional
 DESCRIPTION
 "indicates the maximum number of all types of sensors that can be utilized
per defined array. A typical DCM device will support between 1 to 4 sensors
per array."
::= {dcmSiteSetup 4}

2.6.5     Maximum Number of Arrays
dcmMaxNumArrays OBJECT-TYPE
 SYNTAX INTEGER (1..255)
 ACCESS read-only
 STATUS optional
 DESCRIPTION
 "indicates the maximum number of arrays that can be defined within this
device.   A typical DCM device will support between 4 and 16 arrays.      The
number of arrays that can be defined will also be limited by the amount of IO
fitted in the board. (e.g. the device may have a max of 16 arrays, but if
only 8 loop inputs are present in the device, then only 4 arrays of loop loop
can be configured)."
::= {dcmSiteSetup 5}

2.6.6         Current Number Of Arrays


                                                                                  

                                                                                   
                                                                                  



dcmNumArrays   OBJECT-TYPE
 SYNTAX INTEGER (0..255)
 ACCESS read-only
 STATUS optional
 DESCRIPTION
 "indicates the current number of defined arrays within this DCM device. The
value of this object shall not exceed the value of the dcmMaxNumArrays
object."
::= {dcmSiteSetup 6}

2.6.7     Maximum Number Of Logical IO To Array Mapping Table Rows
dcmLIOMTMaxNumRows OBJECT-TYPE
 SYNTAX DcmMaxNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the maximum number of rows allowed for the Logical IO To Array
Mapping Table."
::= {dcmSiteSetup 7}

2.6.8     Current Number Of Logical IO To Array Mapping Table Rows
dcmLIOMTCurNumRows OBJECT-TYPE
 SYNTAX DcmCurNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the current number of rows existing in the Logical IO To Array
Mapping Table."
::= {dcmSiteSetup 8}

2.6.9     Logical IO To Array Mapping Table
dcmLogicalIOArrayMapTable OBJECT-TYPE
 SYNTAX   SEQUENCE OF DcmLogicalIOArrayMapEntry
 ACCESS   not-accessible
 STATUS   optional
 DESCRIPTION
 "This table assigns logical IO’s from the Physical to Logical IO Mapping
Table to an array. This is a double-indexed table.     Since the logical IO
number is used as the 2nd index into this table, it will most likely not be
sequential.    The table can be managed by the dcmLogicalIOArrayMapRowAdmin
object."
::= {dcmSiteSetup 9}

dcmLogicalIOArrayMapEntry OBJECT-TYPE
 SYNTAX   DcmLogicalIOArrayMapEntry
 ACCESS   not-accessible
 STATUS   mandatory
 DESCRIPTION "..."
 INDEX {dcmIOAMArrNum, dcmIOAMIONum}
::= {dcmLogicalIOArrayMapTable 1}

DcmLogicalIOArrayMapEntry    ::= SEQUENCE
{
 dcmIOAMArrNum                 DcmArrayNum,
 dcmIOAMIONum                  DcmLogIONum,
 dcmIOSpacing                  INTEGER,
 dcmIOPosition                 INTEGER,



                                                                                      

                      
       



 dcmIOFunctionality           INTEGER,
 dcmLogicalIOArrayMapRowAdmin DcmRowStatus
}

2.6.9.1    Array Number
dcmIOAMArrNum OBJECT-TYPE
 SYNTAX   DcmArrayNum
 ACCESS   read-only
 STATUS   mandatory
 DESCRIPTION
 "Indicates the first index into this table.   Refer to DcmArrayNum for more a
detailed description."
::= {dcmLogicalIOArrayMapEntry 1}

2.6.9.2    Logical IO Number
dcmIOAMIONum OBJECT-TYPE
 SYNTAX DcmLogIONum
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Refer to DcmLogIONum for description."
::= {dcmLogicalIOArrayMapEntry 2}


2.6.9.3    IO Spacing
dcmIOSpacing OBJECT-TYPE
 SYNTAX   INTEGER (0..65535)
 ACCESS   read-write
 STATUS   mandatory
 DESCRIPTION
 "Indicates the spacing between each sensor associated with the same array
number (same value of dcmIOAMArrNum).
A value of zero (0) indicates that the specified sensor is the first sensor in
the array. It may also be the only sensor in the array. There shall always
be at least one logical IO associated with an array.      There could also be
multiple IO’s associate with an array (multiple rows in this table)A non-zero
value indicates the distance from the front edge of the first sensor (travel
direction) to the front edge of the sensor defined in this row of this table."
--UNIT       millimeter
::= {dcmLogicalIOArrayMapEntry 3}

2.6.9.4     IO Position
dcmIOPosition OBJECT-TYPE
 SYNTAX    INTEGER
 {
   other (1),
   full (2),
   center (3),
   multiple (4),
   leftHalf (5),
   rightHalf (6),
   leftThird (7),
   centerThird (8),
   rightThird (9),
   above (10),
   below (11),
   sidefire (12),


                                                                                  

                                                                                     
                                                                                    



  wheelPath (13),
  negWheelPath (14)
 }
 ACCESS   read-write
 STATUS   mandatory
 DESCRIPTION
 "indicates the position of a sensor within an array relative to the lane(s)
of travel. The values are:
- other (1),= not defined below.
- full (2),= sensor covers entire lane
- center (3),= sensor is located in the center of the lane, but doesn’t cover
the entire lane
- multiple (4),= sensor crosses multiple lanes
- leftHalf (5),= sensor is located in the left (left sensor relative to the
direction of travel) half of the lane
- rightHalf (6),= sensor is located in the right (right sensor relative to the
direction of travel) half of the lane
- leftThird (7),= sensor is located in the left third of the lane (left sensor
relative to the direction of travel)
- centerThird (8),= sensor is located in the center third of the lane
- rightThird (9),= sensor is located in the right third of the lane (right
sensor relative to the direction of travel)
- above (10),= sensor is located above the lane
- below (11),= sensor is located below the lane
- sidefire (12)= sensor is located perpendicular to the lane
- wheelPath (13)= sensor is located in the wheel path of the lane
- negWheelPath (14)= sensor is located outside of the wheel path in the lane"
::= {dcmLogicalIOArrayMapEntry 4}

2.6.9.5     IO Functionality
dcmIOFunctionality OBJECT-TYPE
 SYNTAX    INTEGER
 {
   other (1),
   vehiclePresence (2),
   axle (3),
   wimAxle (4),
   temperature (5),
   negativeAxle (6),
   onScale (7),
   offScale (8),
   overheight (9),
   avi (10),
   height (11),
   width (12)
 }
 ACCESS    read-write
 STATUS    mandatory
 DESCRIPTION
 " Indicates the generic functionality for the specified logical IO.       The
values are:
- other (1),= not defined below.
- vehiclePresence (2),= the IO can detect the presence of vehicles (e.g. loop)
- axle (3),= the IO can only detect axle strikes (e.g. roadtube)
- wimAxle (4),= the IO is used to determine the weight of an axle (e.g. class
1 piezo)
- temperature (5),= the IO is used to measure temperature




                                                                                        

                      
       



- negativeAxle (6),= the IO is used to subtract out axles (e.g. short long
roadtube configuration)
- onScale (7),= the IO is used to determine if vehicles are tracking in a
consistent position within the lane
- offScale (8),= the IO is used to determine if vehicles are not tracking in a
consistent position within the lane
- overheight (9),= the IO is used to determine if the overall height of a
   vehicle exceeds a maximum height
- avi (10), = Automatic Vehicle Identifier, the IO is used to uniquely
   identify a vehicle
- height (11), = the IO is used to measure vehicle height
- width (12), = the IO is used to measure vehicle width"
::= {dcmLogicalIOArrayMapEntry 5}

2.6.9.6    IO Row Administration
dcmLogicalIOArrayMapRowAdmin OBJECT-TYPE
 SYNTAX   DcmRowStatus
 ACCESS   read-write
 STATUS   optional
 DESCRIPTION
 "allows management of the arrays (this row of this table).          The SYNTAX
definition allows to create, delete, disable, or edit a row."
::= {dcmLogicalIOArrayMapEntry 6}

2.6.10    Maximum Number of Calibration Factors per Array
dcmMaxCalFactorsPerArray    OBJECT-TYPE
 SYNTAX INTEGER (0..255)
 ACCESS read-only
 STATUS optional
 DESCRIPTION
 "indicates the maximum number of calibration factors that can be utilized per
defined array. A typical DCM device will support between 1 to 3 calibration
factors per array."
::= {dcmSiteSetup 10}

2.6.11    Maximum Number Of Array Parameter Table Rows
dcmAPTMaxNumRows OBJECT-TYPE
 SYNTAX DcmMaxNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the maximum number of rows allowed for the Array Parameter Table."
::= {dcmSiteSetup 11}

2.6.12    Current Number Of Array Parameter Table Rows
dcmAPTCurNumRows OBJECT-TYPE
 SYNTAX DcmCurNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the current number of rows existing in the Array Parameter Table."
::= {dcmSiteSetup 12}

2.6.13    Array Parameter Table
dcmArrayParameterTable OBJECT-TYPE
 SYNTAX   SEQUENCE OF DcmArrayParameterEntry


                                                                                  

                                                                                     
                                                                                    



 ACCESS   not-accessible
 STATUS   optional
 DESCRIPTION
 " This table assigns parameters to arrays (typically for the purposes of
fine-tuning the processing of the array within the dcm device.). This is a
double-indexed table.    Since the Array Parameter Type is used as the 2nd
index, it will most likely not be sequential.     The table can be managed
dcmArrayParameterRowAdmin object. "
::= {dcmSiteSetup 13}

dcmArrayParameterEntry OBJECT-TYPE
 SYNTAX   DcmArrayParameterEntry
 ACCESS   not-accessible
 STATUS   mandatory
 DESCRIPTION "..."
 INDEX    {dcmAPArrNum, dcmAPType}
::= {dcmArrayParameterTable 1}

DcmArrayParameterEntry ::= SEQUENCE
{
 dcmAPArrNum               DcmArrayNum,
 dcmAPType                 DcmArrayParamType,
 dcmAPValue                DcmArrayParamValue,
 dcmAPFileName             DcmArrayParamFileName,
 dcmArrayParameterRowAdmin DcmRowStatus
}

2.6.13.1   Array Number
dcmAPArrNum OBJECT-TYPE
 SYNTAX DcmArrayNum
 ACCESS   read-only
 STATUS   mandatory
 DESCRIPTION
 "Indicates the first index into this table.   Refer to DcmArrayNum for a more
detailed description."
::= {dcmArrayParameterEntry 1}

2.6.13.2   Array Parameter Type
dcmAPType OBJECT-TYPE
 SYNTAX DcmArrayParamType
 ACCESS   read-only
 STATUS   mandatory
 DESCRIPTION
 "Indicates the type of parameter associated with an array. One or more types
can be associated with an array.
Refer to DcmArrayParamType for a more detailed description."
::= {dcmArrayParameterEntry 2}

2.6.13.3   Array Parameter Value
dcmAPValue OBJECT-TYPE
 SYNTAX   DcmArrayParamValue
 ACCESS   read-write
 STATUS   mandatory
 DESCRIPTION
 "Indicates the value associated with a particular array parameter type as
specified by the dcmAPType column.   Refer to DcmArrayParamValue for a more
detailed description."



                                                                                        

                      
       



::= {dcmArrayParameterEntry 3}

2.6.13.4   Array Parameter FileName Pointer
dcmAPFileName OBJECT-TYPE
 SYNTAX   DcmArrayParamFileName
 ACCESS   read-write
 STATUS   mandatory
 DESCRIPTION
 "Indicates a file name that contains the array parameter calibration
information. Refer to DcmArrayParamFileName for a more detailed description."
::= {dcmArrayParameterEntry 4}

2.6.13.5   Array Parameter Table Row Administration
dcmArrayParameterRowAdmin OBJECT-TYPE
 SYNTAX   DcmRowStatus
 ACCESS   read-write
 STATUS   mandatory
 DESCRIPTION
 "allows management of the array parameters (this row of this table).          The
SYNTAX definition allows to create, delete, disable, or edit a row."
::= {dcmArrayParameterEntry 5}

2.6.14    Maximum Number Of Array Speed Calibration Table Rows
dcmASCTMaxNumRows OBJECT-TYPE
 SYNTAX DcmMaxNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the maximum number of rows allowed for the Array Speed Calibration
Table."
::= {dcmSiteSetup 14}

2.6.15    Current Number Of Array Speed Calibration Table Rows
dcmASCTCurNumRows OBJECT-TYPE
 SYNTAX DcmCurNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the current number of rows existing in the Array Speed Calibration
Table."
::= {dcmSiteSetup 15}

2.6.16    Array Speed Calibration Table
dcmArraySpeedCalibrationTable OBJECT-TYPE
 SYNTAX   SEQUENCE OF DcmArraySpeedCalibrationEntry
 ACCESS   not-accessible
 STATUS   optional
 DESCRIPTION
 "This table is a triple-indexed table.    It defines the calibration factors
that are used to calibrate a speed algorithm. Historically speed was
calibrated by adjusting sensor spacings within an array. This table allows for
the spacings to remain fixed at the actual values. The table can be managed
thru the dcmArraySpeedCalibrationRowAdmin object."
::= {dcmSiteSetup 16}

dcmArraySpeedCalibrationEntry OBJECT-TYPE



                                                                                  

                                                                                     
                                                                                    



 SYNTAX   DcmArraySpeedCalibrationEntry
 ACCESS   not-accessible
 STATUS   mandatory
 DESCRIPTION "..."
 INDEX    {dcmASCArrNum, dcmLogicalIONumber1, dcmLogicalIONumber2}
::= {dcmArraySpeedCalibrationTable 1}

DcmArraySpeedCalibrationEntry ::= SEQUENCE
{
 dcmASCArrNum           DcmArrayNum,
 dcmLogicalIONumber1    DcmLogIONum,
 dcmLogicalIONumber2    DcmLogIONum,
 dcmArraySpeedCalFactor INTEGER,
 dcmASCRowAdmin         DcmRowStatus
}

2.6.16.1   Array Number
dcmASCArrNum OBJECT-TYPE
 SYNTAX   DcmArrayNum
 ACCESS   read-only
 STATUS   mandatory
 DESCRIPTION
 "Indicates the first index into this table.   Refer to DcmArrayNum for a more
detailed description."
::= {dcmArraySpeedCalibrationEntry 1}


2.6.16.2   First referenced Logical IO Number
dcmLogicalIONumber1 OBJECT-TYPE
 SYNTAX   DcmLogIONum
 ACCESS   read-only
 STATUS   mandatory
 DESCRIPTION
 "Indicates the second index into this table expressing the first speed sensor
that is being used for array speed calibration purposes.       The Logical IO
Number specified must be mapped to the specified array number in the Logical
IO to Array Mapping Table.
Refer to DcmLogIONum for a detailed description."
::= {dcmArraySpeedCalibrationEntry 2}

2.6.16.3   Second referenced Logical IO Number
dcmLogicalIONumber2 OBJECT-TYPE
 SYNTAX   DcmLogIONum
 ACCESS   read-only
 STATUS   mandatory
 DESCRIPTION
 "Indicates the third index into this table expressing the second speed
sensor that is being used for array speed calibration purposes. A value of
‘0’ shall indicate that a 2nd speed sensor is not required to determine speed
(such as a radar detector or a single loop that can determine speed). If a
2nd Logical IO Number is required, it must be mapped to the specified array
number in the Logical IO to Array Mapping Table.
Refer to DcmLogIONum for a detailed description."
::= {dcmArraySpeedCalibrationEntry 3}

2.6.16.4   Array Speed Calibration Factor
dcmArraySpeedCalFactor OBJECT-TYPE


                                                                                        

                      
       



 SYNTAX INTEGER (1..65535)
 ACCESS read-write
 STATUS mandatory
 DESCRIPTION
 "Indicates the adjustment factor to calibrate the measured speed results
reported by the device from the 2 speed sensors specified by the two Logical
IO Number fields in this row of this table. The algorithm to calculate speed
is not defined in this standard. This is a discrete multiplier with no units
with a resolution of .001.    A value of 1000 is equal to 1.000 which would be
a multiplier of 1.000 (no change)."
::= {dcmArraySpeedCalibrationEntry 4}

2.6.16.5    Array Speed Calibration Table Row Administration
dcmASCRowAdmin OBJECT-TYPE
 SYNTAX    DcmRowStatus
 ACCESS    read-write
 STATUS    optional
 DESCRIPTION
 "This object serves as the table row management item. The possible
    values can be found in the definition of the SYNTAX 'DcmRowStatus'."
::= {dcmArraySpeedCalibrationEntry 5}

2.6.17    Max Number of Axles
dcmMaxNumAxles OBJECT-TYPE
 SYNTAX INTEGER (1..255)
 ACCESS read-only
 STATUS optional
 DESCRIPTION
 " indicates the maximum number of axles per vehicle that this device will
support. This is a discrete number and has no units."
::= {dcmSiteSetup 17}

2.6.18    Max Number of Filters
dcmMaxFilters OBJECT-TYPE
 SYNTAX INTEGER (0..255)
 ACCESS read-only
 STATUS optional
 DESCRIPTION
 "indicates the maximum number of filters that can be configured in the filter
table within this device. "
::= {dcmSiteSetup 18}

2.6.19    Current Number Of Filters
dcmNumFilters OBJECT-TYPE
 SYNTAX INTEGER (0..255)
 ACCESS read-only
 STATUS optional
 DESCRIPTION
 "indicates the current number of filters configured for this device.
 This value is updated each time a new filter configuration is added to
 or deleted from the filter table."
::= {dcmSiteSetup 19}

-- A filter defined by the following table always excludes data, e.g. it
-- filters data out. A filter can be defined with multiple conditions (see
-- dcmFilterRowRelation). Parenthesis are always implied around the first two
-- entries of a filter definition (first two is defined by dcmFilterIndex


                                                                                   

                                                                                     
                                                                                    



-- values of 1 and 2), then the result of that with the next condition, and so
-- on.

2.6.20    Maximum Number Of Filter Configuration Table Rows
dcmFCTMaxNumRows OBJECT-TYPE
 SYNTAX DcmMaxNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the maximum number of rows allowed for the Filter Configuration
Table."
::= {dcmSiteSetup 20}

2.6.21    Current Number Of Filter Configuration Table Rows
dcmFCTCurNumRows OBJECT-TYPE
 SYNTAX DcmCurNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the current number of rows existing in the Filter Configuration
Table."
::= {dcmSiteSetup 21}

2.6.22    Filter Configuration Table
dcmFilterConfigTable OBJECT-TYPE
 SYNTAX   SEQUENCE OF DcmFilterConfigEntry
 ACCESS   not-accessible
 STATUS   optional
 DESCRIPTION
 "This table is a doubly-indexed table. It defines the parameters for each
filter definition. The table can be managed thru the dcmFilterConfRowAdmin
object. Each filter defined by this table includes data (filters data in).
Each filter can be defined with multipe conditions (one row per condition).
Parenthesis are always implied around the first two criteria of any filter,
then the result of that with the next criteria, and so on."
::= {dcmSiteSetup 22}

dcmFilterConfigEntry OBJECT-TYPE
 SYNTAX   DcmFilterConfigEntry
 ACCESS   not-accessible
 STATUS   mandatory
 DESCRIPTION "..."
 INDEX    {dcmFCFilterNum, dcmFilterIndex}
::= {dcmFilterConfigTable 1}

DcmFilterConfigEntry ::= SEQUENCE
{
 dcmFCFilterNum        DcmFilterNum,
 dcmFilterIndex        INTEGER,
 dcmFilterCriteria     OBJECT IDENTIFIER,
 dcmFilterRelation     INTEGER,
 dcmFilterValue        INTEGER,
 dcmFilterRowRelation INTEGER,
 dcmFilterConfRowAdmin DcmRowStatus
}

2.6.22.1     Filter Number



                                                                                        

                      
       



dcmFCFilterNum OBJECT-TYPE
 SYNTAX   DcmFilterNum
 ACCESS   read-only
 STATUS   mandatory
 DESCRIPTION
 "Indicates the first index of a particular filter being defined within
the device. Refer to DcmFilterNum for a more detailed description."
::= {dcmFilterConfigEntry 1}

2.6.22.2   Filter Index
dcmFilterIndex OBJECT-TYPE
 SYNTAX   INTEGER (1..3)
 ACCESS   read-only
 STATUS   mandatory
 DESCRIPTION
 "Indicates the second index of a particular filter. Each defined filter
 must have at least one second index defined. The filters shall be processed
in ascending order based on the second index. The first two entries for any
defined filter are processed first, the result of that is then processed with
the next row, the result of that with the 4th, etc.."
::= {dcmFilterConfigEntry 2}

2.6.22.3   Filter Criteria
dcmFilterCriteria OBJECT-TYPE
 SYNTAX OBJECT IDENTIFIER
 ACCESS read-write
 STATUS mandatory
 DESCRIPTION
"Indicates which criteria shall be assigned to this filter (e.g. speed, axle
class, vehicle length…).      The available criteria are defined in the dcm
Vehicle Criteria Node.     Only OID’s of objects that are defined as Integers
that require 4 or less bytes can be used to configure filters."
::= {dcmFilterConfigEntry 3}

2.6.22.4    Filter Relation
dcmFilterRelation OBJECT-TYPE
 SYNTAX    INTEGER
 {
   greaterThan (1),
   lessThan (2),
   equal (3),
   greaterOrEqual (4),
   lessOrEqual (5),
   notEqual (6),
   logicalAnd (7),
   logicalNot (8)
 }
 ACCESS    read-write
 STATUS    mandatory
 DESCRIPTION "Indicates the relationship between dcmFilterCriteria and
dcmFilterValue required to trigger this filter. This data element is valid for
this row, not for interrelationship between rows of a particular filter (see
dcmFCFilterNum and dcmFilterRowRelation). The values are self-explanatory.
In opposite to the common setup of SNMP MIB objects, this object was purposely
setup to NOT include a value of (other).
The values of logicalAnd and logicalNot are used for configuring filters based
on bit-by-bit boolean comparisons of the following objects:



                                                                                  

                                                                                               
                                                                                              



dcmVehicleStatusFlag
dcmAxleWeightViolationCode."
::= {dcmFilterConfigEntry 4}

2.6.22.5   Filter Value
dcmFilterValue OBJECT-TYPE
 SYNTAX   INTEGER (0.. 4294967295) --4 bytes
 ACCESS   read-write
 STATUS   mandatory
 DESCRIPTION
"Indicates the value associated with this filter row. The value shall always
be expressed in 4 bytes. The unit and interpretation of this value shall be
dependent on the value of the dcmFilterCriteria object. The dcmFilterCriteria
objects are defined in the dcm Vehicle Criteria Node."
::= {dcmFilterConfigEntry 5}

2.6.22.6    Filter Row Relation
dcmFilterRowRelation OBJECT-TYPE
 SYNTAX    INTEGER
 {
   and (1),
   or (2),
   endOfDef (3)
 }
 ACCESS    read-write
 STATUS    mandatory
 DESCRIPTION
 "Indicates how several rows with the same value of the DcmFilterNum object
are related to each other. Combines the criteria of a row (dcmFilterIndex)
with the next row (next higher value of the dcmFilterIndex object) within the
same DcmFilterNum.          It is up to the actual implementation (database
population) to ensure that the association of rows is logical. The currently
defined values are:
and – Both criteria of the two rows must be met for the filter to be applied.
or – Either criteria of the two rows must be met for the filter to be applied.
endOfDef – indicates that the criteria of this row is the last criteria valid
             for this DcmFilterNum.
If only one criteria is used per Filter (DcmFilterNum), the value of this
object needs to be set to endOfDef (3).
In opposite to the common setup of SNMP MIB objects, this object was purposely
setup to NOT include a value of (other)."
::= {dcmFilterConfigEntry 6}

2.6.22.7   Filter Configuration Table Row Administration
dcmFilterConfRowAdmin OBJECT-TYPE
 SYNTAX   DcmRowStatus
 ACCESS   read-write
 STATUS   mandatory
 DESCRIPTION
 "This object serves as the table row management item. The possible
values can be found in the definition of the SYNTAX 'DcmRowStatus'."
::= {dcmFilterConfigEntry 7}

2.6.23    Maximum Number Of Logical Output To Filter Table Rows
dcmLOFTMaxNumRows OBJECT-TYPE
 SYNTAX DcmMaxNumRows
 ACCESS read-only


                                                                                                  

                      
       



 STATUS mandatory
 DESCRIPTION
 "Indicates the maximum number of rows allowed for the Logical Output To
Filter Table."
::= {dcmSiteSetup 23}

2.6.24    Current Number Of Logical Output To Filter Table Rows
dcmLOFTCurNumRows OBJECT-TYPE
 SYNTAX DcmCurNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the current number of rows existing in the Logical Output To
Filter Table."
::= {dcmSiteSetup 24}

2.6.25     Logical Output To Filter Mapping Table
dcmOFMTable OBJECT-TYPE
 SYNTAX    SEQUENCE OF DcmOFMEntry
 ACCESS    not-accessible
 STATUS    optional
 DESCRIPTION
   "This table defines a mapping from a logical output (Logical IO Number which
is specifically an output) to one or more filters. Multiple filters can be
mapped to a single logical output through multiple rows in this table. The
different filters in each row are related through the Boolean entry in this
table. The Boolean relationships are processed in ascending order (as defined
by the 2nd index) of entries assigned to the specified logical output. The
last row associated with each logical output must have the Boolean column set
to ‘end of definition’. If an application attempts to set more rows
associated with a single logical output than is allowed, an application error
of ‘exceededMaxNumberOfAllowedOccurrences’ shall be set.
This is a double-indexed table. The table can be managed thru dcmOFMRowAdmin
object. Additionally, this table may be cleared using the User Reset Table."
::= {dcmSiteSetup 25}

dcmOFMEntry OBJECT-TYPE
 SYNTAX   DcmOFMEntry
 ACCESS   not-accessible
 STATUS   mandatory
 DESCRIPTION "..."
 INDEX {dcmOFMIONum, dcmOFMIndex}
::= {dcmOFMTable 1}

DcmOFMEntry ::= SEQUENCE
{
 dcmOFMIONum     DcmLogIONum,
 dcmOFMIndex     INTEGER,
 dcmOFMFilterNum DcmFilterNum,
 dcmOFMState     INTEGER,
 dcmOFMStateTime INTEGER,
 dcmOFMRelation INTEGER,
 dcmOFMRowAdmin DcmRowStatus
}

2.6.25.1   OFM IO Num
dcmOFMIONum OBJECT-TYPE



                                                                                   

                                                                                      
                                                                                     



 SYNTAX DcmLogIONum
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the first index into this table.   Refer to DcmLogIONum for
description."
::= {dcmOFMEntry 1}

2.6.25.2    Output Filter Map Index
dcmOFMIndex OBJECT-TYPE
 SYNTAX    INTEGER (1..255)
 ACCESS    read-only
 STATUS    mandatory
 DESCRIPTION
   "Indicates the second index into this table. This index must be assigned
sequentially.      It is used to map and Boolean relate multiple filters
(specified by dcmOFFFilterNum) to a single logical output. The value of
dcmOFMRelation column determines the type of Boolean processing to occur on
the specified filters. The first two entries are processed first, the result
of that is then processed with the next row, the result of that with the 4th,
etc."
::= {dcmOFMEntry 2}

2.6.25.3   Filter Number
dcmOFMFilterNum OBJECT-TYPE
 SYNTAX   DcmFilterNum
 ACCESS   read-write
 STATUS   mandatory
 DESCRIPTION
 "Indicates a defined filter (from the dcm Filter Configuration Table) to be
mapped to the output specified by dcmOMFIONum. Refer to DcmFilterNum for a
more detailed description."
::= {dcmOFMEntry 3}

2.6.25.4    Output State
dcmOFMState OBJECT-TYPE
 SYNTAX    INTEGER
 {
   other (1),
   turnOn (2),
   turnOff (3),
   pulse (4)
 }
 ACCESS    read-write
 STATUS    mandatory
 DESCRIPTION
 "Indicates the state the output specified by dcmOMFIONum shall go to when the
specified defined filter relationship is triggered. The value of this object
shall only be valid in rows in which the value of the dcmOFMRelation object is
set to 3 (endOfDef), otherwise the value of this object shall be ignored. The
values are:
-other=not defined
-turnOn=specified output shall turn on for the period of time specified by
dcmOMFStateTime.       If dcmOMFStateTime=0, the output shall remain in the
specified state indefinitely.




                                                                                         

                      
       



-turnOff=specified output shall turn off for the period of time specified by
dcmOMFStateTime. If dcmOMFStateTime=0, the output shall remain in the
specified state indefinitely.
-pulse=specified output shall pulse one time. The amount of time the pulse is
active for shall be specified by dcmOMFStateTime. If dcmOMFStateTime=0, the
pulse shall be the default pulse time (which is implementation-specific) for
the specified output."
::= {dcmOFMEntry 4}

2.6.25.5   Output State Time
dcmOFMStateTime OBJECT-TYPE
 SYNTAX   INTEGER (0..16777215)
 ACCESS   read-write
 STATUS   mandatory
 DESCRIPTION
 "Indicates the time (in milliseconds) that the logical output shall remain in
the state specified by dcmOMFState. If dcmOFMState=0, the output shall remain
in the specified state indefinitely.
The value of this object shall only be valid in rows in which the value of the
dcmOMFRelation object is set to 3 (endOfDef), otherwise the value of this
object shall be ignored."
::= {dcmOFMEntry 5}

2.6.25.6    Output Filter Map Relationship
dcmOFMRelation OBJECT-TYPE
 SYNTAX INTEGER
 {
   and (1),
   or (2),
   endOfDef (3)
 }
 ACCESS    read-write
 STATUS    mandatory
 DESCRIPTION
 "Indicates how multiple filters can be related together to trigger the
specified logical output. It is up to the application to ensure that the rows
are populated in the correct sequence to achieve the desired Boolean
relationship. The Boolean relationships are processed in an ascending order
as specified by the second index within each logical output. If 3 rows were
defined (1-1-and, 1-2-or, 1-3-end) the result would be that logical output 1
is triggered if ((filter 1 and filter 2) or filter 3)=True.       The currently
defined values are:
and (1) – This defines a Boolean ‘and’ operation between the filter specified
             in this row and the filter defined in the next row for the same
             logical output as determined by the second index of this table.
             The logical output shall not be triggered unless both filters are
             true.
or (2) – This defines a Boolean ‘or’ operation between the filter specified in
             this row and the filter defined in the next row for the same
             logical output as determined by the second index of this table.
             The logical output shall not be triggered unless either one of the
             filters are true.
endOfDef (3) – Indicates that this row is the end of the definition for the
             criteria required to trigger the specified logical output.
If only one mapping is used per output (this row), the value of this object
shall be set to endOfDef.




                                                                                   

                                                                                      
                                                                                     



In opposite to the common setup of SNMP MIB objects, this object was purposely
setup to NOT include a value of (other)."
::= {dcmOFMEntry 6}

2.6.25.7   Output Filter Map Row Admin
dcmOFMRowAdmin OBJECT-TYPE
 SYNTAX   DcmRowStatus
 ACCESS   read-write
 STATUS   mandatory
 DESCRIPTION
 "Allows   management      of  the   associated  ‘logical   output/filter number
combination’ (this row of this table).          The SYNTAX definition allows to
create, delete, disable, or edit the row.          This object cannot be set to
‘active’ until a row associated with the specified logical output exists with
endOfDef.    This is a slightly different usage of this object in that it
requires a relationship between multiple rows."
::= {dcmOFMEntry 7}

2.6.26    Max Number of Vehicle ID’s
dcmMaxNumVehId OBJECT-TYPE
 SYNTAX INTEGER (1..255)
 ACCESS read-only
 STATUS optional
 DESCRIPTION
 "Indicates the maximum number of vehicle ID’s per vehicle that this device
shall support. This is a discrete number and has no units."
::= {dcmSiteSetup 26}


2.7   STUDY SETUP NODE
--DCM Study Setup Node
dcmStudyConfig OBJECT IDENTIFIER ::= {dcm 5}
-- This node is an identifier used to group all objects for configuring
-- one or more studies. The objects utilized are common to data collection
-- and monitoring devices.


2.7.1     Current Number Of Studies
dcmNumStudies OBJECT-TYPE
 SYNTAX INTEGER (0..255)
 ACCESS read-only
 STATUS optional
 DESCRIPTION
 "Indicates the current number of studies defined in the dcmStudyConfigTable
within this dcm device."
::= {dcmStudyConfig 1}

2.7.2     Maximum Number of Studies
dcmMaxNumStudies OBJECT-TYPE
 SYNTAX INTEGER (1..255)
 ACCESS read-only
 STATUS optional
 DESCRIPTION
 "Indicates the maximum number of all types of studies that can be defined
within this device. A typical DCM device will support between 1 and 3 studies
being defined simultaneously."


                                                                                         

                      
       



::= {dcmStudyConfig 2}

2.7.3     Maximum Number Of Study Configuration Table Rows
dcmSCTMaxNumRows OBJECT-TYPE
 SYNTAX DcmMaxNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the maximum number of rows allowed for the Study Configuration
Table."
::= {dcmStudyConfig 3}

2.7.4     Current Number Of Study Configuration Table Rows
dcmSCTCurNumRows OBJECT-TYPE
 SYNTAX DcmCurNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the current number of rows existing in the Study Configuration
Table."
::= {dcmStudyConfig 4}

2.7.5     Study Configuration Table
dcmStudyConfigTable OBJECT-TYPE
 SYNTAX SEQUENCE OF DcmStudyConfigEntry
 ACCESS not-accessible
 STATUS optional
 DESCRIPTION
 "This table defines the required parameters to configure studies for either
data recording or Monitor Modes.    The number of rows in this table cannot
exceed the maximum number of studies (dcmMaxNumStudies) and shall be the same
as the dcmNumStudies object value. This is a single-indexed table. The table
can be managed thru dcmStudyConfigRowAdmin object."
::= {dcmStudyConfig 5}

dcmStudyConfigEntry OBJECT-TYPE
 SYNTAX DcmStudyConfigEntry
 ACCESS not-accessible
 STATUS mandatory
 DESCRIPTION "..."
 INDEX {dcmSCStudyNum}
::= {dcmStudyConfigTable 1}

DcmStudyConfigEntry ::= SEQUENCE
{
 dcmSCStudyNum          DcmStudyNum,
 dcmStudyType           INTEGER,
 dcmStartType           INTEGER,
 dcmStartDateTime       Counter,
 dcmEndType             INTEGER,
 dcmEndDateTime         Counter,
 dcmSCFileStudyIndex    DcmFileStudyIndex,
 dcmStudyConfigRowAdmin DcmRowStatus
}

2.7.5.1    Study Number
dcmSCStudyNum OBJECT-TYPE


                                                                                 

                                                                                    
                                                                                   



 SYNTAX DcmStudyNum
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the only index into this table. It represents a unique number for
each study that is defined within the device in this table. It is recommended
to assign this value sequentially, however deleting studies may produce gaps
in the indexes. It is recommended to use the deleted study number as the next
one to assign as an attempt to keep these indexes sequential."
::= {dcmStudyConfigEntry 1}

2.7.5.2     Study Type
dcmStudyType OBJECT-TYPE
 SYNTAX INTEGER
 {
   other (1),
   binned (2),
   pvr (3),
   event (4),
   arrayParam (5),
   logicalIOParam (6),
   log (7)
 }
 ACCESS read-write
 STATUS mandatory
 DESCRIPTION
 "Indicates the type of study that is being configured within this row. The
values are:
- other (1) - Not defined below.
- binned (2) - Processes data based on user-defined aggregated bins (details
are configured in Binned Filter Definition Table and Binned Study
Configuration Table).
- pvr (3) - Processes user-defined data for each vehicle (details are
configured in PVR Study Configuration Table).
- event (4) - Processes data based on raw IO (details are configured in Event
Study Configuration Table and Event To Logical IO Mapping Table).
- arrayParam (5) – Processes sensor array parameter changes to a data file.
The structure of the array parameter data record is defined by the Array
Parameter Change Record Table.
- logicalIOParam (6) - Processes logical IO parameter changes to a data file.
The structure of the logical IO parameter data record is defined by the
Logical IO Parameter Change Record Table.
- log (7) – Processes log data to a data file.       The structure of the log
records are defined by the Log Data Record Table."
::= {dcmStudyConfigEntry 2}

2.7.5.3     Study Start Type
dcmStartType OBJECT-TYPE
 SYNTAX    INTEGER
 {
   other (1),
   now (2),
   nextInterval (3),
   dateTime (4)
 }
 ACCESS    read-write
 STATUS    mandatory
 DESCRIPTION


                                                                                       

                      
       



 "indicates how the study defined in this row is supposed to start.        The
values are:
- other = not defined below
- now = as soon as the DCM device receives the command, it shall begin
recording. This may result in having partial data for a recording interval.
- nextInterval = as soon as the next even recording interval starts, the study
shall begin recording, e.g., if the dcmFPRecInt is ‘3600’ (1 hour) recording
shall begin at the next full hour. This will ensure that no partial recording
intervals are stored.
- dateTime = The device shall begin recording data at the date/time as
specified in the dcmStartDateTime object."
::= {dcmStudyConfigEntry 3}

2.7.5.4    Study Start Date and Time
dcmStartDateTime OBJECT-TYPE
 SYNTAX   Counter
 ACCESS   read-write
 STATUS   mandatory
 DESCRIPTION
 "If Study Start Type is set to dateTime, then this object indicates the date
and time at which the study is to start. The value of this object follows the
‘controller-localTime’ setup, which specifies the epoch since Midnight January
1, 1970.    For all other selections of Study Start Type, this object is
meaningless."
::= {dcmStudyConfigEntry 4}

2.7.5.5     Study End Type
dcmEndType OBJECT-TYPE
 SYNTAX INTEGER
 {
   other (1),
   never (2),
   dateTime(3)
 }
 ACCESS    read-write
 STATUS    mandatory
 DESCRIPTION
 "Indicates how long the defined study shall run for.      At the end of the
specified time, the study shall be set to idle by the device but it shall not
be removed from this table. The values are:
- other = not defined below
- never = The study shall run forever. The only way to end the study is to
disable it through the Data Recording Enable Table (quitRecording option for
Data Recording Control).
- dateTime = the study shall end at the specified date and time specified in
the dcmEndDateTime object."
::= {dcmStudyConfigEntry 5}

2.7.5.6    Study End Date and Time
dcmEndDateTime OBJECT-TYPE
 SYNTAX   Counter
 ACCESS   read-write
 STATUS   mandatory
 DESCRIPTION
 "If Study End Type is set to dateTime, then this object indicates the date
and time at which the study is to end. The value of this object follows the
‘controller-localTime’ setup, which specifies the epoch since Midnight January



                                                                                  

                                                                                          
                                                                                         



1, 1970.    For all other selections    of    Study   End   Type,    this    object      is
meaningless."
::= {dcmStudyConfigEntry 6}

2.7.5.7    Study File Index
dcmSCFileStudyIndex OBJECT-TYPE
 SYNTAX   DcmFileStudyIndex
 ACCESS   read-write
 STATUS   mandatory
 DESCRIPTION
 "Defines the file structure number within the File Structure Table (non-zero
values). A value of zero (0) indicates that no data shall be recorded and the
study is to be used for Monitor Modes (see the Monitor Enable Table)."
::= {dcmStudyConfigEntry 7}

2.7.5.8    Study Configuration Row Admin
dcmStudyConfigRowAdmin OBJECT-TYPE
 SYNTAX   DcmRowStatus
 ACCESS   read-write
 STATUS   mandatory
 DESCRIPTION
 "Allows management of the parameters used to configure a study (this row of
this table). The SYNTAX definition allows to create,delete, disable, or edit
the row. If a study is deleted from this table, the device shall delete all
rows in any other table that references that study. It is highly recommended
that the application make every attempt to keep the study number sequential
(reuse study numbers that have been deleted)."
::= {dcmStudyConfigEntry 8}

2.7.6     Maximum Number Of Array To Study Mapping Table Rows
dcmASMTMaxNumRows OBJECT-TYPE
 SYNTAX DcmMaxNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the maximum number of rows allowed for the Array To Study Mapping
Table."
::= {dcmStudyConfig 6}

2.7.7     Current Number Of Array To Study Mapping Table Rows
dcmASMTCurNumRows OBJECT-TYPE
 SYNTAX DcmCurNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the current number of rows existing in the Array To Study Mapping
Table."
::= {dcmStudyConfig 7}

2.7.8     Array To Study Mapping Table
dcmStudyArrayMapTable OBJECT-TYPE
 SYNTAX   SEQUENCE OF DcmStudyArrayMapEntry
 ACCESS   not-accessible
 STATUS   optional
 DESCRIPTION




                                                                                            

                      
       



 "Defines which sensor arrays are mapped to which studies. It is also used to
enable/disable sensor arrays assigned to studies.   This is a double-indexed
table, with both indices defined in previous tables. The table can be managed
thru dcmStudyArrayRowAdmin object.    If a study is deleted from the Study
Configuration Table, the device shall delete any entries in this table
associated with that study."
::= {dcmStudyConfig 8}

dcmStudyArrayMapEntry OBJECT-TYPE
 SYNTAX   DcmStudyArrayMapEntry
 ACCESS   not-accessible
 STATUS   mandatory
 DESCRIPTION "..."
 INDEX    {dcmSAMStudyNum, dcmSAMArrNum}
::= {dcmStudyArrayMapTable 1}

DcmStudyArrayMapEntry ::= SEQUENCE
{
 dcmSAMStudyNum          DcmStudyNum,
 dcmSAMArrNum            DcmArrayNum,
 dcmStudyArrayEnable     INTEGER,
 dcmStudyArrayRowAdmin   DcmRowStatus
}

2.7.8.1    Study Number
dcmSAMStudyNum OBJECT-TYPE
 SYNTAX DcmStudyNum
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the first index into this table. It represents a unique number for
each study that is defined within the device in the dcmStudyConfigTable.
Refer to DcmStudyNum for more detail."
::= {dcmStudyArrayMapEntry 1}

2.7.8.2    Array Number
dcmSAMArrNum OBJECT-TYPE
 SYNTAX   DcmArrayNum
 ACCESS   read-only
 STATUS   mandatory
 DESCRIPTION
 "Indicates the first index into this table.   Refer to DcmArrayNum for a more
detailed description."
::= {dcmStudyArrayMapEntry 2}

2.7.8.3     Study to Array Enable
dcmStudyArrayEnable OBJECT-TYPE
 SYNTAX    INTEGER
 {
   enable (1),
   disable (2)
 }
 ACCESS    read-write
 STATUS    mandatory
 DESCRIPTION
 "Indicates whether a particular defined array is active within the specified
study.



                                                                                  

                                                                                     
                                                                                    




enable – sensor inputs associated with this array shall be processed by the
device.
disable – sensor inputs associated with this array shall not be processed by
the device. The device may choose to either ignore those sensor inputs, or
turn off the sensors within the Physical to Logical IO Mapping Table.
Typically an array may be turned off for diagnostic purposes.
In opposite to the common setup of SNMP MIB objects, this object was purposely
setup to NOT include a value of (other). "
::= {dcmStudyArrayMapEntry 3}

2.7.8.4    Array to Study Mapping Table Row Admin
dcmStudyArrayRowAdmin OBJECT-TYPE
 SYNTAX   DcmRowStatus
 ACCESS   read-write
 STATUS   mandatory
 DESCRIPTION
 "Allows management of the parameters used to configure a study (this row of
this table). The SYNTAX definition allows to create,delete, disable, or edit
the row. "
::= {dcmStudyArrayMapEntry 4}

2.7.9     Maximum Number Of Filter To Study Mapping Table Rows
dcmFSMTMaxNumRows OBJECT-TYPE
 SYNTAX DcmMaxNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the maximum number of rows allowed for the Filter To Study Mapping
Table."
::= {dcmStudyConfig 9}

2.7.10    Current Number Of Filter To Study Mapping Table Rows
dcmFSMTCurNumRows OBJECT-TYPE
 SYNTAX DcmCurNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the current number of rows existing in the Filter To Study Mapping
Table."
::= {dcmStudyConfig 10}

2.7.11    Filter to Study Mapping Table
dcmStudyFilterMapTable OBJECT-TYPE
 SYNTAX   SEQUENCE OF DcmStudyFilterMapEntry
 ACCESS   not-accessible
 STATUS   optional
 DESCRIPTION
 "Defines the parameters to map selected filters to each of the defined
studies.
This is a double-indexed table, with both indices defined in previous tables.
The table can be managed thru dcmStudyFilterMapRowAdmin object.
Multiple filters may be assigned to the same study.     The first two filters
assigned to a study shall be processed, the result of that processed with the
next filter assigned to the study, and so on."
::= {dcmStudyConfig 11}



                                                                                        

                      
       



dcmStudyFilterMapEntry OBJECT-TYPE
 SYNTAX   DcmStudyFilterMapEntry
 ACCESS   not-accessible
 STATUS   mandatory
 DESCRIPTION "..."
 INDEX    {dcmSFMStudyNum, dcmSFMFilterNum}
::= {dcmStudyFilterMapTable 1}

DcmStudyFilterMapEntry ::= SEQUENCE
{
 dcmSFMStudyNum            DcmStudyNum,
 dcmSFMFilterNum           DcmFilterNum,
 dcmStudyFilterRelation    INTEGER,
 dcmStudyFilterMapRowAdmin DcmRowStatus
}

2.7.11.1   Study Number
dcmSFMStudyNum OBJECT-TYPE
 SYNTAX DcmStudyNum
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the first index into this table. It represents a unique number for
each study that is defined within the device in the dcmStudyConfigTable.
Refer to DcmStudyNum for more detail."
::= {dcmStudyFilterMapEntry 1}

2.7.11.2   Filter Number
dcmSFMFilterNum OBJECT-TYPE
 SYNTAX   DcmFilterNum
 ACCESS   read-only
 STATUS   mandatory
 DESCRIPTION
 "Indicates a defined filter (from the dcm Filter Configuration Table) to be
mapped to the study specified by dcmSFMStudyNum. Refer to DcmFilterNum for a
more detailed description."
::= {dcmStudyFilterMapEntry 2}

2.7.11.3    Study to Filter Mapping Relationship
dcmStudyFilterRelation OBJECT-TYPE
 SYNTAX INTEGER
 {
   and (1),
   or (2),
   endOfDef (3)
 }
 ACCESS    read-write
 STATUS    mandatory
 DESCRIPTION
 "Indicates how several rows (filters) with the same value of the
dcmSFMStudyNum object are related to each other. It is up to the actual
implementation (database population) to ensure that the association of rows is
logical. The first two entries for any defined filter are processed first,
the result of that is then processed with the next row, the result of that
with the 4th, etc. The currently defined values are:




                                                                                  

                                                                                     
                                                                                    



and (1) – combine the criteria of this row (dcmSFMFilterNum) with the next row
            (next higher value of the dcmSFMFilterNum object) within the same
            dcmSFMStudyNum.
or (2) – select the criteria of either this row (dcmSFMFilterNum) or of the
            next row (next higher value of the dcmSFMFilterNum object) within
            the same dcmSFMStudyNum.
endOfDef (3) – indicates that the criteria of this row is the last criteria
            valid for this dcmSFMStudyNum.
If only one criteria is used per study (dcmSFMStudyNum), the value of this
object shall be set to ‘endOfDef’.
In opposite to the common setup of SNMP MIB objects, this object was purposely
setup to NOT include a value of (other)."
::= {dcmStudyFilterMapEntry 3}

2.7.11.4      Filter to Study Mapping Table Row Admin
dcmStudyFilterMapRowAdmin OBJECT-TYPE
  SYNTAX     DcmRowStatus
  ACCESS     read-write
  STATUS     mandatory
  DESCRIPTION
  "Allows management of the parameters used to configure a study filter (this
row of this table). The SYNTAX definition allows to create, delete, disable,
or edit the row. If any of the filters are deleted, the device shall
automatically delete them from this table. A value of ‘createAndGo’ is only
valid in rows in which the Study to Filter Mapping Relationship is set to
EndOfDef."
::= {dcmStudyFilterMapEntry 4}

2.8   STUDY DATA SETUP NODE
--DCM Study Data Setup Node
dcmStudyDataSetup OBJECT IDENTIFIER ::= {dcm 6}
-- This node is an identifier used to group all objects for configuring
-- a data collection session that are common to data collection and
-- monitoring devices.

2.8.1      Display Length Units
dcmLengthUnits OBJECT-TYPE
 SYNTAX INTEGER
 {
   centimeter (1), -- internal units
   decimeter (2),
   meter       (3),
   inches      (4),
   tenthFeet (5),
   feet        (6)
 }
 ACCESS read-write
 STATUS optional
 DESCRIPTION
 "Indicates the units in which length is displayed for ASCII Monitor Mode
output and/or any local user interface (keyboard/display) that is used to
enter length such as bin limits or length filter limits. The length values
shall always be stored in internal units as defined for each object and not in
display units.
The currently defined values are:
 -centimeter (1) – 0.01 meter (internal units), (1 centimeter=0.3937 inches)
 -decimeter (2) – 0.1 meter (1 decimeter=3.937 inches)


                                                                                        

                      
       



 -meter (3) – (1 meter=39.37 inches=3.281 feet)
 -inches (4) – (1 inch=2.54 centimeters)
 -tenthFeet (5) – 0.1 feet (1 foot=12 inches)
 -feet (6) – (1 foot=12 inches)
"
::= {dcmStudyDataSetup 1}

2.8.2      Display Speed Units
dcmSpeedUnits OBJECT-TYPE
 SYNTAX INTEGER
 {
   cms (1), -- internal units
   kmh (2),
   mph (3)
 }
 ACCESS read-write
 STATUS optional
 DESCRIPTION
 "Indicates the units in which speed is displayed for ASCII Monitor Mode
output and/or any local user interface (keyboard/display) that is used to
enter speed such as bin limits or speed filter limits. The speed values shall
always be stored in internal units as defined for each object and not in
display units.
The currently defined values are:
 -cms (1) – centimeters per second (internal units)
 -kmh (2) – kilometers per hour
 -mph (3) – miles per hour
"
::= {dcmStudyDataSetup 2}

2.8.3      Display Weight Units
dcmWeightUnits OBJECT-TYPE
 SYNTAX INTEGER
 {
   tenthTonne (1),
   tenthKips (2),
   pounds      (3),
   kilograms (4), -- internal units
   kips        (5)
 }
 ACCESS read-write
 STATUS optional
 DESCRIPTION
 "Indicates the units in which weight is displayed for ASCII Monitor Mode
output and/or any local user interface (keyboard/display) that is used to
enter weight such as bin limits or weight filter limits. The weight values
shall always be stored in internal units as defined for each object and not in
display units.
The currently defined values are:
 -tenthTonne (1) – 0.1 Tonne (1 Tonne=2204.62 pounds)
 -tenthKips (2) – 0.1 Kips (1 KIP=1000 pounds)
 -pounds (3) – (1 pound=0.4536 kilograms)
 -kilograms (4) – internal units, (1 kilogram=2.2046 pounds)
 -kips (5) – 1 kip (1 KIP=1000 pounds)
"
::= {dcmStudyDataSetup 3}




                                                                                  

                                                                                           
                                                                                          



2.8.4     Maximum Number of Headings For All Studies
dcmMaxNumHeadings OBJECT-TYPE
 SYNTAX INTEGER (0..255)
 ACCESS read-only
 STATUS optional
 DESCRIPTION
 "Indicates the maximum number of headings (which are used in the Binned Study
Configuration Table to configure studies) that can be configured for all
binned studies. A typical DCM device will support between 1 to 3 headings that
can be defined for each study giving a typical maximum of between 3 to 9
headings for all studies.     As an example, if the max is 9 headings, there
could be 6 headings assigned to study 1, 1 heading to study 2 and 2 headings
to study 3."
::= {dcmStudyDataSetup 4}

2.8.5     Maximum Number of Bins For All Studies
dcmMaxNumBins OBJECT-TYPE
 SYNTAX INTEGER (0..65535)
 ACCESS read-only
 STATUS optional
 DESCRIPTION
 "Indicates the maximum number of bins that can be defined over all binned
studies. A typical DCM device may support a maximum binning of 15 classes by
15 speeds by 4 lanes (15x15x4)=900 bins for all studies. As an example, the
900 bins could also be broken into 200 bins for study 1, 500 bins for study 2
and 200 bins for study 3. The 200 bins for study 1 could then be broken up
into 20 bins for heading 1 of study 1 and 10 bins for heading 2 of study 1 (20
bins x 10 bins=200 bins)."
::= {dcmStudyDataSetup 5}

2.8.6     Maximum Number Of Binned Filter Definition Table Rows
dcmBFDTMaxNumRows OBJECT-TYPE
 SYNTAX DcmMaxNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the maximum number of rows allowed for                the    Binned      Filter
Definition Table."
::= {dcmStudyDataSetup 6}

2.8.7     Current Number Of Binned Filter Definition Table Rows
dcmBFDTCurNumRows OBJECT-TYPE
 SYNTAX DcmCurNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the current number of rows existing in                the    Binned      Filter
Definition Table."
::= {dcmStudyDataSetup 7}

2.8.8     Binned Filter Definition Table
dcmBinnedFilterDefTable OBJECT-TYPE
 SYNTAX   SEQUENCE OF DcmBinnedFilterDefEntry
 ACCESS   not-accessible
 STATUS   optional
 DESCRIPTION



                                                                                              

                      
       



 "This table is used to create definitions of ranges that can be applied to
bins in the Bin Relation Table. This is a double-indexed table. The table can
be managed thru dcmBinnedFilterDefRowAdmin object. It is recommended that all
indexes be assigned sequentially by the application.     There can be multiple
ranges assigned to any one Binned Filter.      Parenthesis are always implied
around the first two entries assigned to the same Binned Filter for
processing.   The results of that are then processed with the next range
assigned to this binned filter. Configuring a binned study with two headings
(15 bins of classification x 12 bins of speed) would require defining 27 bins
(entries in this table), 15 bins of class + the 12 bins of speed.
--Note that the value stored in each bin is an aggregate count and not a
--calculated value (e.g. a bin cannot contain the average gross weight of
--vehicles, but it can contain how many vehicles had an average gross
--weight that is within the bin range limits)."
::= {dcmStudyDataSetup 8}

dcmBinnedFilterDefEntry OBJECT-TYPE
 SYNTAX   DcmBinnedFilterDefEntry
 ACCESS   not-accessible
 STATUS   mandatory
 DESCRIPTION "..."
 INDEX   {dcmBFDBinnedFilterNum, dcmBinnedFilterIndex}
::= {dcmBinnedFilterDefTable 1}

DcmBinnedFilterDefEntry            ::= SEQUENCE
{
 dcmBFDBinnedFilterNum      DcmBinnedFilterNum,
 dcmBinnedFilterIndex       INTEGER,
 dcmBinHeading              OBJECT IDENTIFIER, -- (reference objects created
                             -- for each of the enumerations from
                             -- the Vehicle Criteria Table.)
 dcmBinMinimumValue         INTEGER,
 dcmBinMaximumValue         INTEGER,
 dcmBinNumberIndexRelation INTEGER,
 dcmBinnedFilterDefRowAdmin DcmRowStatus
}

2.8.8.1    Binned Filter Number
dcmBFDBinnedFilterNum OBJECT-TYPE
 SYNTAX   DcmBinnedFilterNum
 ACCESS   read-only
 STATUS   mandatory
 DESCRIPTION
 "Indicates the first index into this table. It represents a unique         number
for each binned filter that is being defined within the device.             It is
strongly suggested that the numbering is assigned sequentially. This        number
can never exceed the maximum number of bins for all studies                 object
(dcmMaxNumBins). Refer to DcmBinnedFilterNum for more information."
::= {dcmBinnedFilterDefEntry 1}

2.8.8.2    Binned Filter Index
dcmBinnedFilterIndex OBJECT-TYPE
 SYNTAX   INTEGER (1..255)
 ACCESS   read-only
 STATUS   mandatory
 DESCRIPTION
 "Indicates the second index into this table.  This value allows assigning
more than one heading type (and the associated lower and upper limit) to a


                                                                                   

                                                                                    
                                                                                   



binned filter (e.g. assign class 9 or class 11 to this bin). It is strongly
suggested that the numbering is assigned sequentially."
::= {dcmBinnedFilterDefEntry 2}

2.8.8.3    Bin Heading
dcmBinHeading OBJECT-TYPE
 SYNTAX   OBJECT IDENTIFIER
 ACCESS   read-write
 STATUS   mandatory
 DESCRIPTION
 "This contains the OID of the type of data (taken from the dcm vehicle
criteria node) to be binned for this Binned Filter definition. A volume study
can be configured by specifying the Array Number OID."
::= {dcmBinnedFilterDefEntry 3}

2.8.8.4    Bin Minimum Value
dcmBinMinimumValue OBJECT-TYPE
 SYNTAX   INTEGER (0..16777215)
 ACCESS   read-write
 STATUS   mandatory
 DESCRIPTION
 "Indicates the lower range value for this bin (this row of the table). The
meaning of this value is dependent on the value of the dcmBinHeading object
assigned to this row. When binning data, all compare values that are greater
than or equal to the value of this object and less than the value of
dcmBinMaximumValue for this Binned Filter must be assigned to this bin."
::= {dcmBinnedFilterDefEntry 4}

2.8.8.5    Bin Maximum Value
dcmBinMaximumValue OBJECT-TYPE
 SYNTAX   INTEGER (0..16777215)
 ACCESS   read-write
 STATUS   mandatory
 DESCRIPTION
 "Indicates the upper range value for this bin (this row of the table). The
meaning of this value is dependent on the value of the dcmBinHeading object
assigned to this row. All compare values that are smaller than the value of
this object and greater than or equal to the dcmBinMinimumValue for this
Binned Filter must be assigned to this bin."
::= {dcmBinnedFilterDefEntry 5}

2.8.8.6     Bin Number to Index Relationship
dcmBinNumberIndexRelation OBJECT-TYPE
 SYNTAX    INTEGER
 {
   and (1),
   or (2),
   endOfDef (3)
 }
 ACCESS    read-write
 STATUS    mandatory
 DESCRIPTION
 "Indicates how several rows with the same value of the dcmBinnedFilterNumber
object are related to each other. It is up to the actual implementation
(database population) to ensure that the association of rows is logical. The
first two entries for any defined binned filters are processed first, the



                                                                                       

                      
       



result of that is then processed with the next row, the result of that with
the 4th, etc. The currently defined values are:
and (1) – combine the criteria of this row with the next row (next higher
             value of the secondary index object) within the same primary index
             number object.
or (2) – select the criteria of either this row or that of the next row (next
             higher value of the same secondary index object) within the same
             primary index number object.
endOfDef (3) – indicates that the criteria of this row is the last criteria
             valid for this primary index number object.
If only one dcmFilterCriteria is used per binned filter, the value of this
object shall be set to ‘endOfDef’.
In opposite to the common setup of SNMP MIB objects, this object was purposely
setup to NOT include a value of (other)."
::= {dcmBinnedFilterDefEntry 6}

2.8.8.7    Binned Filter Definition Table Row Admin
dcmBinnedFilterDefRowAdmin OBJECT-TYPE
 SYNTAX   DcmRowStatus
 ACCESS   read-write
 STATUS   mandatory
 DESCRIPTION
 "Allows management of the parameters used to configure the definitions of a
binned filter (this row of this table).             The SYNTAX definition allows to
create, delete, disable, or edit the row."
::= {dcmBinnedFilterDefEntry 7}

2.8.9     Maximum Number Of Binned Study Configuration Table Rows
dcmBSCTMaxNumRows OBJECT-TYPE
 SYNTAX DcmMaxNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the maximum number of rows allowed for the                Binned    Study
Configuration Table."
::= {dcmStudyDataSetup 9}

2.8.10    Current Number Of Binned Study Configuration Table Rows
dcmBSCTCurNumRows OBJECT-TYPE
 SYNTAX DcmCurNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the current number of rows existing in the Binned Study Definition
Table."
::= {dcmStudyDataSetup 10}

2.8.11    Binned Study Configuration Table
dcmBinSCTable OBJECT-TYPE
 SYNTAX   SEQUENCE OF DcmBinSCEntry
 ACCESS   not-accessible
 STATUS   optional
 DESCRIPTION
 "This table is used to relate Binned Filters to headings within studies (e.g.
Study 1 Heading 1 Bin 1 is Speed (0-10mph),…). This is a triple-indexed table.
The table can be managed thru dcmBSCRowAdmin object. If a Binned Filter is
deleted in the Binned Filter Definition Table, the device shall automatically


                                                                                      

                                                                                     
                                                                                    



delete any entry within this table that refers to the deleted Binned Filter
Number."
::= {dcmStudyDataSetup 11}

dcmBinSCEntry OBJECT-TYPE
 SYNTAX   DcmBinSCEntry
 ACCESS   not-accessible
 STATUS   mandatory
 DESCRIPTION "..."
 INDEX    {dcmBSCStudyNum, dcmBSCHeadingNum, dcmBSCLabelNum}
::= {dcmBinSCTable 1}

DcmBinSCEntry ::= SEQUENCE
{
 dcmBSCStudyNum   DcmStudyNum,
 dcmBSCHeadingNum INTEGER,
 dcmBSCLabelNum   INTEGER,
 dcmBSCFilterNum DcmBinnedFilterNum,
 dcmBSCRowAdmin   DcmRowStatus
}

2.8.11.1   Study Number
dcmBSCStudyNum OBJECT-TYPE
 SYNTAX DcmStudyNum
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the first index into this table. It represents a unique number for
each study that is defined within the device in the dcmStudyConfigTable.
Refer to DcmStudyNum for more detail."
::= {dcmBinSCEntry 1}

2.8.11.2   Heading Number
dcmBSCHeadingNum OBJECT-TYPE
 SYNTAX   INTEGER (1..255)
 ACCESS   read-only
 STATUS   mandatory
 DESCRIPTION
 "Indicates the second index into this table. It represents a unique heading
number for each study that is being defined within the device. It is strongly
suggested that the numbering is assigned sequentially.     Typically a device
would support up to 3 headings per study. A Boolean ‘and’ is always implied
across all of the specified headings for a study (e.g. if 3 bins of class
(1,2,3) are specified for heading 1 of study 1 and 2 bins of speed (0-5mph, 5-
10mph) are specified for heading 2 of study 1, then bin 1 would be any vehicle
that was a class 1 and had a speed between 0-5mph, bin 2 would be any vehicle
that was a class 2 and had a speed between 0-5mph, …). The combination of all
the headings specified for all the studies shall never exceed the maximum
number of headings for all studies object (dcmMaxNumHeadings)."
::= {dcmBinSCEntry 2}

2.8.11.3   Bin Label Number
dcmBSCLabelNum OBJECT-TYPE
 SYNTAX   INTEGER (1..255)
 ACCESS   read-only
 STATUS   mandatory
 DESCRIPTION



                                                                                        

                      
       



 "Indicates the third index into this table. This value allows assigning more
than one bin label to each heading number and each study number. For example,
if study 1 heading 1 required 5 bins to be assigned, 5 rows would be required
with this index spanning from 1 to 5. It is strongly suggested that the
numbering is assigned sequentially."
::= {dcmBinSCEntry 3}

2.8.11.4   Binned Filter Number
dcmBSCFilterNum OBJECT-TYPE
 SYNTAX   DcmBinnedFilterNum
 ACCESS   read-only
 STATUS   mandatory
 DESCRIPTION
 "This object represents a unique number for each binned filter that has been
defined within the ‘dcm Binned Filter Definition Table’.            Refer to
DcmBinnedFilterNum for more information."
::= {dcmBinSCEntry 4}

2.8.11.5   Bin Relation Table Row Admin
dcmBSCRowAdmin OBJECT-TYPE
 SYNTAX   DcmRowStatus
 ACCESS   read-write
 STATUS   mandatory
 DESCRIPTION
 "Allows management of the parameters used to configure the relations of a
binned filter (this row of this table).    The SYNTAX definition allows to
create, delete, disable, or edit the row."
::= {dcmBinSCEntry 5}

2.8.12    Maximum Number Of PVR Study Configuration Table Rows
dcmPSCTMaxNumRows OBJECT-TYPE
 SYNTAX DcmMaxNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the maximum number of rows allowed for the PVR Study Configuration
Table."
::= {dcmStudyDataSetup 12}

2.8.13    Current Number Of PVR Study Configuration Table Rows
dcmPSCTCurNumRows OBJECT-TYPE
 SYNTAX DcmCurNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the current number of rows existing in the PVR Study Configuration
Table."
::= {dcmStudyDataSetup 13}

2.8.14    PVR Study Configuration Table
dcmPvrStudyConfigTable OBJECT-TYPE
 SYNTAX   SEQUENCE OF DcmPvrStudyConfigEntry
 ACCESS   not-accessible
 STATUS   optional
 DESCRIPTION




                                                                                  

                                                                                      
                                                                                     



 "This is a doubly-indexed table. It defines the parameters to configure PVR
studies. The parameters specified define both the pvr study as well as the
structure for the data packets to be stored in the Data Structure Table. The
table can be managed thru dcmPvrStudyConfigRowAdmin object.     If a study is
deleted from the Study Configuration Table, any entries within this table that
refer to that study shall be automatically deleted by the device."
::= {dcmStudyDataSetup 14}

dcmPvrStudyConfigEntry OBJECT-TYPE
 SYNTAX   DcmPvrStudyConfigEntry
 ACCESS   not-accessible
 STATUS   mandatory
 DESCRIPTION "..."
 INDEX {dcmPSCStudyNum, dcmPvrStudyIndex}
::= {dcmPvrStudyConfigTable 1}

DcmPvrStudyConfigEntry ::= SEQUENCE
{
 dcmPSCStudyNum            DcmStudyNum,
 dcmPvrStudyIndex          INTEGER,
 dcmPvrParam               OBJECT IDENTIFIER,
 dcmPvrStudyConfigRowAdmin DcmRowStatus
}

2.8.14.1   Study Number
dcmPSCStudyNum OBJECT-TYPE
 SYNTAX DcmStudyNum
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the first index into this table. It represents a unique number for
each study that is defined within the device in the dcmStudyConfigTable.
Refer to DcmStudyConfig for more detail."
::= {dcmPvrStudyConfigEntry 1}

2.8.14.2   PVR Study Index
dcmPvrStudyIndex OBJECT-TYPE
 SYNTAX INTEGER (1..255)
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "indicates the second index into this table.   This allows specifying to store
multiple vehicle parameters for each study."
::= {dcmPvrStudyConfigEntry 2}

2.8.14.3   PVR Parameter
dcmPvrParam OBJECT-TYPE
 SYNTAX   OBJECT IDENTIFIER
 ACCESS   read-write
 STATUS   mandatory
 DESCRIPTION
 "This field contains the OID of the specified pvr parameter to store from the
dcm Vehicle Criteria node. The OID specified must be a full OID from the root
of the iso tree, relative OID’s cannot be used.      This allows referring to
objects outside of this MIB. The objects specified here can be either single
or multi-occurrence objects as defined by the object referred to by this OID
in the Vehicle Criteria Node. Refer to the description at the beginning of



                                                                                         

                      
       



the Vehicle Criteria Node. The order of the PVR parameters, in this table,
specifies the order of the data in the PVR data packet."
::= {dcmPvrStudyConfigEntry 3}

2.8.14.4   PVR Study Configuration Table Row Admin
dcmPvrStudyConfigRowAdmin OBJECT-TYPE
 SYNTAX   DcmRowStatus
 ACCESS   read-write
 STATUS   mandatory
 DESCRIPTION
 "Allows management of the parameters used to configure a PVR study (this row
of this table). The SYNTAX definition allows to create, delete, disable, or
edit the row."
::= {dcmPvrStudyConfigEntry 4}

2.8.15    Maximum Number Of Event Study Configuration Table Rows
dcmESCTMaxNumRows OBJECT-TYPE
 SYNTAX DcmMaxNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the maximum number of rows allowed for                 the   Event   Study
Configuration Table."
::= {dcmStudyDataSetup 15}

2.8.16    Current Number Of Event Study Configuration Table Rows
dcmESCTCurNumRows OBJECT-TYPE
 SYNTAX DcmCurNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the current number of rows existing in                 the   Event   Study
Configuration Table."
::= {dcmStudyDataSetup 16}

2.8.17    Event Study Configuration Table
dcmEventStudyConfigTable OBJECT-TYPE
 SYNTAX   SEQUENCE OF DcmEventStudyConfigEntry
 ACCESS   not-accessible
 STATUS   optional
 DESCRIPTION
 "This table is used to configure an Event Study. The fields configured in
this table define the number of bits to identify the size of an event and how
frequently a timer event would be placed in the data. This uses Study Number
as the single-index into the table. This table requires row administration.
There shall be one row defined in this table for each required event study.
The table can be managed thru dcmEventStudyConfigRowAdmin object."
::= {dcmStudyDataSetup 17}

dcmEventStudyConfigEntry OBJECT-TYPE
 SYNTAX   DcmEventStudyConfigEntry
 ACCESS   not-accessible
 STATUS   mandatory
 DESCRIPTION "..."
 INDEX    {dcmESCStudyNum}
::= {dcmEventStudyConfigTable 1}



                                                                                       

                                                                                     
                                                                                    



DcmEventStudyConfigEntry ::= SEQUENCE
{
 dcmESCStudyNum              DcmStudyNum,
 dcmEventNumberSize          INTEGER,
 dcmTimerEventMaxPeriod      INTEGER,
 dcmEventStudyConfigRowAdmin DcmRowStatus
 }
2.8.17.1   Study Number
dcmESCStudyNum OBJECT-TYPE
 SYNTAX DcmStudyNum
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the only index into this table. It represents a unique number for
each study that is defined within the device in the dcmStudyConfigTable.
Refer to DcmStudyConfig for more detail."
::= {dcmEventStudyConfigEntry 1}

2.8.17.2   Event Number Size
dcmEventNumberSize OBJECT-TYPE
 SYNTAX   INTEGER (1..255)
 ACCESS   read-write
 STATUS   mandatory
 DESCRIPTION
 "This indicates the number of bits required to store an event number. This
shall reflect the total number of events that are mapped to this event study
in the Event To Logical IO Mapping Table. For example, if this value is set
to two, then there can only be a maximum of four distinct events that can be
identified.
The value cannot be set to zero (0), since it would indicate that there are no
event #’s to refer to in the Event To Logical IO Mapping Table."
::= {dcmEventStudyConfigEntry 2}

2.8.17.3   Timer Event Maximum Period
dcmTimerEventMaxPeriod OBJECT-TYPE
 SYNTAX   INTEGER (1..4294967295)
 ACCESS   read-write
 STATUS   mandatory
 DESCRIPTION
 "This field identifies the maximum number of milliseconds that can be
contained in the timestamp stored within each event(see dcmTimeStampSize).
If a timer is defined as an event # in the Event To Logical IO Mapping table,
the value of dcmTimerEventMaxPeriod defines the period between timer events.
If a timer is not identified as an event in the Event To Logical IO Mapping
Table, no timer events shall be stored, this field shall be ignored."
::= {dcmEventStudyConfigEntry 3}

2.8.17.4   Event Study Config Table Row Admin
dcmEventStudyConfigRowAdmin OBJECT-TYPE
 SYNTAX   DcmRowStatus
 ACCESS   read-write
 STATUS   mandatory
 DESCRIPTION
 "Allows management of the parameters used to configure an event study (this
row of this table). The SYNTAX definition allows to create, delete, disable,
or edit the row."
::= {dcmEventStudyConfigEntry 4}


                                                                                        

                      
       




2.8.18    Maximum Number Of Event To Logical IO Mapping Table Rows
dcmELIMTMaxNumRows OBJECT-TYPE
 SYNTAX DcmMaxNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the maximum number of rows allowed for the Event To Logical IO
Mapping Table."
::= {dcmStudyDataSetup 18}

2.8.19    Current Number Of Event To Logical IO Mapping Table Rows
dcmELIMTCurNumRows OBJECT-TYPE
 SYNTAX DcmCurNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the current number of rows existing in the Event To Logical IO
Mapping Table."
::= {dcmStudyDataSetup 19}

2.8.20    Event To Logical IO Mapping Table
dcmEventConfigTable OBJECT-TYPE
 SYNTAX   SEQUENCE OF DcmEventConfigEntry
 ACCESS   not-accessible
 STATUS   optional
 DESCRIPTION
 "This table maps logical IO’s to a unique event number within a particular
study. The parameters allow defining the structure of each event data that is
to be recorded. An event is defined as a specific state of a logical IO and
given a unique event # for a particular study. The parameters are related to
a particular study number to allow for multiple structures for the same input.
An IO event record as stored in the data portion of an event data packet would
consist of an Event # (dcmEventNum), Event Value (# of bits specified by
dcmEventValueSize), Timestamp (# of bits specified by dcmTimestampSize). The
size of the IO event would be the sum of the Event # Size
(dcmEventNumberSize), Event Value Size (dcmEventValueSize) and the
Timestampsize (dcmTimestampSize).
Therefore to decipher the bitstream in an event record, the       first x bits
(dcmEventNumberSize) of each data element would identify the Event Number and
this table would define how many bits follow for the event value and event
timestamp.
This is a single-indexed table. The index is assigned sequentially and the
table requires row administration. There shall be one row in this table for
each event # mapped to an event study.
The table can be managed thru the dcmEventConfigRowAdmin object."
::= {dcmStudyDataSetup 20}

dcmEventConfigEntry OBJECT-TYPE
 SYNTAX   DcmEventConfigEntry
 ACCESS   not-accessible
 STATUS   mandatory
 DESCRIPTION "..."
 INDEX    {dcmECStudyNum,dcmEventConfigNumber}
::= {dcmEventConfigTable 1}

DcmEventConfigEntry ::= SEQUENCE



                                                                                  

                                                                                     
                                                                                    



{
 dcmECStudyNum          DcmStudyNum,
 dcmEventConfigNumber   INTEGER,
 dcmEventNumber         INTEGER,
 dcmECIONum             DcmLogIONum,
 dcmLogicalIOState      INTEGER,
 dcmEventValueSize      INTEGER,
 dcmTimestampSize       INTEGER,
 dcmEventConfigRowAdmin DcmRowStatus
}
2.8.20.1
2.8.20.2   Study Number
dcmECStudyNum OBJECT-TYPE
 SYNTAX DcmStudyNum
 ACCESS read-write
 STATUS mandatory
 DESCRIPTION
 "Indicates a unique number for each study that is defined within the device
in the dcmStudyConfigTable. Refer to DcmStudyConfig for more detail."
::= {dcmEventConfigEntry 1}

2.8.20.3   Event Configuration Number
dcmEventConfigNumber OBJECT-TYPE
 SYNTAX   INTEGER (1..255)
 ACCESS   read-only
 STATUS   mandatory
 DESCRIPTION
 "This is a unique number that is used to create a sequential index (within
each Study number) for this table.    This is the second index of the table.
Although dcmEventNumber could be used as the second index, it would require a
larger number of bits to store an event since an index cannot be assigned a
value of zero and thus would have to start at one. For example, a study with
two events (Event # 1, Event # 2, (note that Event # 0 cannot be used)) would
have to use two bits in each event record rather than one (two bits are
required to represent the number 2 for Event # 2). Using Event Config # as a
separate index provides for the least number of bits to be stored in the event
data record."
::= {dcmEventConfigEntry 2}

2.8.20.4   Event Number
dcmEventNumber OBJECT-TYPE
 SYNTAX   INTEGER (0..255)
 ACCESS   read-only
 STATUS   mandatory
 DESCRIPTION
 "This is a unique sequential number assigned by the equipment for each event
within this study. The first event number shall be 0 and subsequent events
shall be numbered sequentially for the same study number in order to limit the
number of bits necessary to identify all the events for a study. Note that
the event number can be repeated for different studies, e.g. there can be an
event number 0 for Study 1 and event number 0 for Study 2. When a study is
validated or set to prime, the device shall verify that all event numbers
relative to the same study in this table are sequential. An application error
of ‘validationFailed’ shall be reported if they are not."
::= {dcmEventConfigEntry 3}




                                                                                        

                      
       



2.8.20.5   Logical IO Number
dcmECIONum OBJECT-TYPE
 SYNTAX DcmLogIONum
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Refer to DcmLogIONum for description."
::= {dcmEventConfigEntry 4}

2.8.20.6    Logical IO State
dcmLogicalIOState OBJECT-TYPE
 SYNTAX    INTEGER
 {
   other (1),
   on (2),
   off (3),
   weight (4),
   pulsed (5),
   triggered (6),
   valueA-D (7)
 }
 ACCESS    read-write
 STATUS    mandatory
 DESCRIPTION
 "This field defines the specific logical IO states (e.g., on, off, etc) that
are used to determine if an event has occurred.    The values are:
other (1) – not defined below
on (2) – Logical IO has turned on.
off (3) – Logical IO has turned off.
weight (4) – This event record represents a raw weight.
pulsed (5) – Logical IO has been pulsed.
triggered (6) – Logical IO has been triggered.
valueA-D (7) – This event record represents a raw analog to digital count."
::= {dcmEventConfigEntry 5}

2.8.20.7   Event Value Size
dcmEventValueSize OBJECT-TYPE
 SYNTAX   INTEGER (0..255)
 ACCESS   read-only
 STATUS   mandatory
 DESCRIPTION
 "This object identifies the number of bits necessary to store a value
associated with this event (e.g., weight, A/D value,    etc….) that is to be
recorded within the data structure. This object shall be set by the equipment
based on the logical IO associated to this event. Note that this size can be
different for each logical IO.
If the value is set to zero (0), no value field is contained in the data
structure for this event."
::= {dcmEventConfigEntry 6}

2.8.20.8   Timestamp Size
dcmTimestampSize OBJECT-TYPE
 SYNTAX   INTEGER (0..255)
 ACCESS   read-only
 STATUS   mandatory
 DESCRIPTION



                                                                                 

                                                                                     
                                                                                    



 "This object identifies the number of bits used to record the timestamp of an
event within the data structure. The time stamp of an event is referenced to
the start of the study or a timer event, whichever occurred last. If the value
is set to zero (0), no timestamp field is contained in the data structure.
The time stamp resolution associated with this dcmECStudyNum is calculated by
(dcmTimerEventMaxPeriod / (2^(dcmTimestampSize)))."
::= {dcmEventConfigEntry 7}

2.8.20.9   Event Configuration Table Row Admin
dcmEventConfigRowAdmin OBJECT-TYPE
 SYNTAX   DcmRowStatus
 ACCESS   read-write
 STATUS   mandatory
 DESCRIPTION
 "allows management of the parameters used to configure an event study (this
row of this table). The SYNTAX definition allows to create, delete, disable,
or edit the row."
::= {dcmEventConfigEntry 8}

2.8.21    Maximum Number Of Data Recording Enable Table Rows
dcmDRETMaxNumRows OBJECT-TYPE
 SYNTAX DcmMaxNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the maximum number of rows allowed for the Data Recording Enable
Table."
::= {dcmStudyDataSetup 21}

2.8.22    Current Number Of Data Recording Enable Table Rows
dcmDRETCurNumRows OBJECT-TYPE
 SYNTAX DcmCurNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the current number of rows existing in the Data Recording Enable
Table."
::= {dcmStudyDataSetup 22}

2.8.23    Data Recording Enable Table
dcmDRETable OBJECT-TYPE
 SYNTAX SEQUENCE OF DcmDREEntry
 ACCESS not-accessible
 STATUS optional
 DESCRIPTION
 "This table is single-indexed by study number.    It is used to control and
read the state of each data recording study. The device must ensure that there
exists an entry in this table for each data recording study defined in the
Study Configuraton Table. A ‘data recording study’ is defined as any study
that has been entered into the Study Configuration Table that has a ‘Study
File Index’ greater than 0. If a study is deleted from the Study Configuration
Table, the device shall also delete it from this table."
::= {dcmStudyDataSetup 23}

dcmDREEntry OBJECT-TYPE
 SYNTAX DcmDREEntry
 ACCESS not-accessible


                                                                                        

                      
       



 STATUS mandatory
 DESCRIPTION "..."
 INDEX {dcmDREStudyNum}
::= {dcmDRETable 1}

DcmDREEntry ::= SEQUENCE
{
 dcmDREStudyNum DcmStudyNum,
 dcmDREStatus   INTEGER,
 dcmDREControl INTEGER
}

2.8.23.1   Study Number
dcmDREStudyNum OBJECT-TYPE
 SYNTAX DcmStudyNum
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the only index into this table. It represents a unique number for
each study that is defined within the device in the dcmStudyConfigTable.
Refer to DcmStudyConfig for more detail."
::= {dcmDREEntry 1}

2.8.23.2    Data Recording Enable Status
dcmDREStatus OBJECT-TYPE
 SYNTAX INTEGER
 {
   other (1),
   idle (2),
   primed (3),
   recording (4),
   validating (5),
   error (6)
 }
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the status of this study. The values are:
- other (1),= Not defined below.
- idle (2),= The device is currently not recording any data for this study to
a file.
- primed (3),= The device is waiting to start recording data to a file (either
for the next even recording interval or a scheduled date/time).
- recording (4),= The device is currently recording data to the specified file
for this study.
- validati\ng (5),= The device is currently validating the configured study.
The device can only be in this state if the value of the dcmDREControl object
has been set to ‘validate’ or ‘prime’.
 - error (6)= Indicates any error associated with this study including invalid
configuration setups.       The dcmErrCodeTable should be checked to determine
which objects caused the errors."
::= {dcmDREEntry 2}

2.8.23.3   Data Recording Control
dcmDREControl OBJECT-TYPE
 SYNTAX INTEGER
 {



                                                                                  

                                                                                     
                                                                                    



  prime (1),
  quitRecording (2),
  validate (3)
 }
 ACCESS read-write
 STATUS mandatory
 DESCRIPTION
 "This object allows a user to command the device to:
-prime – Sets device into a state where it is waiting to begin data recording
(typically waiting for the start of the next even recording interval or some
scheduled start date/time).    The device shall perform a validation before
going to primed. If there are no errors, the device shall go into the primed
state.    If there are errors, the device shall indicate ‘error’ in the
dcmDREStatus object. The dcmErrCodeTable should be checked for which objects
caused the errors.
-quitRecording – The device shall stop collecting and storing data to the data
files.   This can be used when the device is either in the ‘primed’ mode or
‘recording’ mode as indicated by the Data Recording Status field in this
table.
-validate – Commands the device to perform a validation of the current study
settings for the specified study. This control option is only valid when the
device is in idle or error mode as indicated by the Data Recording Enable
Status object.    If the Data Recording Status field is set to error after
performing the validation, the dcmErrCodeTable should be checked to determine
which object caused the errors.     The dcmDREStatus object shall be set to
either idle or error after the validation is finished. A GET on this object
shall return the value of the last user-selected control."
::= {dcmDREEntry 3}

2.8.24    Maximum Number Of Monitor Enable Table Rows
dcmMETMaxNumRows OBJECT-TYPE
 SYNTAX DcmMaxNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the maximum number of rows allowed for the Monitor Enable Table."
::= {dcmStudyDataSetup 24}

2.8.25    Current Number Of Monitor Enable Table Rows
dcmMETCurNumRows OBJECT-TYPE
 SYNTAX DcmCurNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the current number of rows existing in the Monitor Enable Table."
::= {dcmStudyDataSetup 25}

2.8.26    Monitor Enable Table
dcmMETable OBJECT-TYPE
 SYNTAX SEQUENCE OF DcmMEEntry
 ACCESS not-accessible
 STATUS optional
 DESCRIPTION
 "This table is single-indexed by study number.
It is used to control and read the state of each ‘Monitor Study’.
A Binned Monitor Study shall return the bin counts for the current recording
interval as defined by the ‘Data’ column of the Data Structure Table for



                                                                                        

                      
       



Binned Data (note that in asciiData Monitor Modes, the number of octets per
binned count is not sent).
A PVR Monitor Study shall return one or more PVR/s as defined by the ‘Data’
column of the Data Structure Table for PVR Data (note that in asciiData
Monitor Modes, the dcm device may translate the vehicle time tag to a more
user friendly format (e.g. ‘mm/dd/yy hh:mm:ss’).
An Event Monitor Study shall return one or more sensor events (Logical IO
Events) as defined by the ‘Data’ column of the Data Structure Table for Event
Data (note that in asciiData Monitor Modes, the ascii hex representation of
each event record field will be sent since event records are defined in bits).
The ‘Data’ column of the Data Structure Table is an OCTET STRING, it will
contain the length of the data returned by the device for each type of Monitor
Mode 2 (binary data).    The OCTET STRING identifier and length field is not
included for asciiData Monitor Modes.
Note that it may possible for vehicles or sensor events (Logical IO events) to
be missed if the device does not have sufficient buffer space to hold the data
before being polled (specifically in Monitor Mode 2). This should only occur
with either PVR or Event Monitor Studies. There currently is no mechanism to
notify the central application that a data over-run has occurred. The best
approach (if possible) would be to use Monitor Mode 1 allowing the device to
stream out the data as it occurs.     This however requires that the central
application can keep up with the streamed data.
Monitor Studies are typically used to verify operation of sensors and sensor
arrays.
For example, if the data in collected data files appear to be invalid, a user
may want to configure an ‘Event Monitor Study’ (in the Study Configuration
Table) that incorporates the same sensors in which the invalid data has been
produced by. The user would then enable the ‘Event Monitor Mode’ from within
this table. The user would examine the event data returned by the device to
determine if all of the specified sensors appear to be operating correctly.
Monitor Studies are typically turned on for a short period of time and then
disabled. The data is sent to a hardware communications port and not saved to
a data file.
The study specified in this table must point to a ‘Monitor Study’. A ‘Monitor
Study’ is defined as any study that has been configured in the Study
Configuration Table with it’s ‘Study File Index’ set to 0.
The asciiData Monitor Modes are intended to provide user-readable output
without interpretation and is included for historical purposes.
The Row Admin field is not required in this table. If a study is deleted from
the Study Configuration Table, the device shall also delete any row associated
with the same study number from this table."
::= {dcmStudyDataSetup 26}

dcmMEEntry OBJECT-TYPE
 SYNTAX DcmMEEntry
 ACCESS not-accessible
 STATUS mandatory
 DESCRIPTION "..."
 INDEX {dcmMEStudyNum}
::= {dcmMETable 1}

DcmMEEntry ::= SEQUENCE
{
 dcmMEStudyNum     DcmStudyNum,
 dcmMEIONum        DcmLogIONum,
 dcmMEType         INTEGER,
 dcmMETimeInterval INTEGER,
 dcmMEControl      INTEGER,



                                                                                  

                                                                                     
                                                                                    



 dcmMEStatus           INTEGER,
 dcmMEPollNow          OCTET STRING
}

2.8.26.1     Study Number
dcmMEStudyNum OBJECT-TYPE
 SYNTAX DcmStudyNum
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the only index into this table. It represents a unique number for
the      specified    Monitor Study   that    is   configured    within   the
dcmStudyConfigTable."
::= {dcmMEEntry 1}

2.8.26.2   Logical IO Number
dcmMEIONum OBJECT-TYPE
 SYNTAX DcmLogIONum
 ACCESS read-write
 STATUS mandatory
 DESCRIPTION
 "Identifies which hardware communications port to which the Monitor Mode data
shall be sent. Refer to DcmLogIONum for more detail."
::= {dcmMEEntry 2}

2.8.26.3    Monitor Enable Type
dcmMEType OBJECT-TYPE
 SYNTAX INTEGER
 {
   other (1),
   asciiData (2),
   binaryData (3)
 }
 ACCESS read-write
 STATUS mandatory
 DESCRIPTION
 "Indicates the encoding of the data packet returned by the device.       The
values are:
-other(1)=not defined.

-asciiData(2)=data packet is encoded using an ascii representation of the
‘Data’ column of the Data Structure Table. This mode of operation is intended
to provide the user with readable data directly from the device without
requiring interpretation (it is included for historical purposes). Each field
of the data packet (a defined bin for a binned study, a pvr parameter for a
pvr study, or each field of an event record for an event study) shall be
separated by a ‘white space’ (either an ascii space, ascii comma, ascii tab).
Each record (all of the binned counts for a binned study, each set of vehicle
parameters for a pvr study and each logical IO event record for an event
study), will be terminated by a ‘white terminator’ (an ascii carriage return,
an ascii line feed or a combination ascii carriage return/line feed). Because
each field is separated by an ascii ‘white space’, the dcn device may choose
to pad each field with leading ascii zeros (ascii code h30) to make each
identical field the same length for readability. The octet string code (04h)
and the length of the octet string fields are not sent in asciiData mode. The
number of octets per binned counts for binned studies is not sent. The
vehicle time tag for pvr studies may be translated by before being sent. The



                                                                                        

                      
       



data fields sent for event studies shall be the ascii hex representation of
each defined field since event records are defined in bits.

-binaryData(3)=data packet is encoded in binary. The data is encoded as
defined by the ‘Data’ field of the Data Structure Table for the specified type
of data."
::= {dcmMEEntry 3}

2.8.26.4   Monitor Enable Time Interval
dcmMETimeInterval OBJECT-TYPE
 SYNTAX INTEGER (0..255)
 ACCESS read-write
 STATUS mandatory
 DESCRIPTION
"Indicates the time (in seconds) between the sending of each data packet for
the specified Monitor Mode. This column is only valid for Monitor Mode 1
configurations, it shall be ignored for Monitor Mode 2.
Setting this to 0 shall cause the device to send a data packet for every
occurrence of the specified study type data, (PVR Monitor Mode – a data packet
shall be sent for each vehicle that traverses the associated sensor array/s,
Event Monitor Mode – a data packet shall be sent for each change of state of
the associated sensor/s, Binned Monitor Mode – 0 shall not be a valid option,
the device shall return an error code of ‘invalidOption’ as the result of a
‘validate’."
::= {dcmMEEntry 4}

2.8.26.5    Monitor Enable Control
dcmMEControl OBJECT-TYPE
 SYNTAX INTEGER
 {
   validate (1),
   enableMon1 (2),
   enableMon2 (3),
   disableMon (4)
 }
 ACCESS read-write
 STATUS mandatory
 DESCRIPTION
 "This object allows a user to command the device to:
-validate – Commands the device to perform a validation of the current study
settings for the specified study. If the Monitor Enable Status field is set
to error after performing the validation, the dcmErrCodeTable should be
checked to determine which object caused the errors.
-enableMon1On – Commands the device to enable Monitor Mode 1 (refer to
dcmMEStatus for a description of Monitor Mode 1).     If a validation of the
specified study hasn’t been performed yet, the device shall perform a
validation. After the validation, this study shall either be in error, idle
or a Monitor Mode On state. If an error occurs, the application should check
the dcm Error Code table (dcmErrCodeTable) for more information regarding the
errors.
-enableMon2On – Commands the device to enable Monitor Mode 2 (see dcmMEStatus
for a description of Monitor Mode 2). If a validation of the specified study
hasn’t been performed yet, the device shall perform a validation. After the
validation, this study shall either be in error, idle or a Monitor Mode On
state. If an error occurs, the application should check the dcm Error Code
table (dcmErrCodeTable) for more information regarding the errors.
-disableMon – Commands the device to disable Monitor Mode.



                                                                                  

                                                                                               
                                                                                              



A GET on this object         shall   return   the   value   of   the   last   user-selected
control."
::= {dcmMEEntry 5}

2.8.26.6    Monitor Enable Status
dcmMEStatus OBJECT-TYPE
 SYNTAX INTEGER
 {
   other (1),
   error (2),
   validating (3),
   monitorMode1On (4),
   monitorMode2On (5),
   idle(6)
 }
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the status of this study. The values are:
- other (1) = Not defined below.
- error (2) = There was an error in the ‘Monitor Study’ found by the device
when it was commanded to enable a Monitor Mode.       Check the dcm Error Code
Table (dcmErrCodeTable) for more information regarding the error.
- validating (3) = The device is currently validating the configured study.
The device can only be in this state if the value of the dcmDREControl object
has been set to ‘validate’ or a Monitor Mode was enabled.
- monitorMode1On (4)= Indicates that the device has successfully enabled
Monitor Mode 1. Monitor Mode 1 is an asynchronous mode of operation where the
device shall asynchronously stream out data packets (as defined by the ‘Data’
field in the Data Structure Table for the specified study) without any
protocol wrapper.      The time between the device sending each data packet is
defined by dcmMETimeInterval.
This mode should only be enabled in a point to point communications
architecture since there is no protocol wrapper around the streamed data. This
mode has been included for compatibility with existing systems.
- monitorMode2On (5) = Indicates that the device has successfully enabled
Monitor Mode 2. Monitor Mode 2 is a synchronous mode of operation in which
each data packet must be polled for by the application. The encoding of each
data packet shall be defined by the ‘Data’ field of the Data Structure Table
for the specified type of study) The dcmMEPollNow column in this row shall be
used to poll for each data packet. Each time the application performs a ‘Get’
on the dcmMEPollNow column, the device shall respond by sending a data packet.
The data packet shall contain all of the associated data from the time of the
last poll up to the current time.
- idle (6) = No Monitor Modes are enabled."
::= {dcmMEEntry 6}

2.8.26.7   Monitor Enable Poll Now
dcmMEPollNow OBJECT-TYPE
 SYNTAX OCTET STRING
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "This column is only valid for Monitor Mode 2.        Anytime an application
performs a ‘GET’ on this column, the device shall respond by sending back a
data packet (as defined by the ‘Data’ column of the ‘Data Structure Table’ for




                                                                                                  

                      
       



the specified study).    If Monitor Mode 2 is not enabled for this Monitor
Study, the device shall respond with an OCTET STRING of size 0 octets."
::= {dcmMEEntry 7}

2.8.27    Array Parameter Change Record Table
dcmAPCTable OBJECT-TYPE
 SYNTAX   SEQUENCE OF DcmAPCEntry
 ACCESS   not-accessible
 STATUS   optional
 DESCRIPTION
"This table has been defined to specify a data structure record format for any
array parameter changes that need to be written to the dcmDataStructureTable,
it is not accessible by the central application. The time tag column has been
defined as the index for syntax purposes only, there really are no indexes for
this table.
Since this table represents raw data, each column of this table shall be
stored in the ‘data’ column of the dcmDataStructureTable using the encoding
specified by the ‘File Encoding Code’ in the ‘File Parameter Table’ for this
study."
::= {dcmStudyDataSetup 27}

dcmAPCEntry OBJECT-TYPE
 SYNTAX   DcmAPCEntry
 ACCESS   not-accessible
 STATUS   mandatory
 DESCRIPTION "..."
 INDEX    {dcmAPCTimeTag}
::= {dcmAPCTable 1}

DcmAPCEntry ::= SEQUENCE
{
 dcmAPCTimeTag DcmTimeTagIndex,
 dcmAPCArrNum   DcmArrayNum,
 dcmAPCType     DcmArrayParamType,
 dcmAPCValue    DcmArrayParamValue,
 dcmAPCFileName DcmArrayParamFileName
}

2.8.27.1   Time Tag
dcmAPCTimeTag OBJECT-TYPE
 SYNTAX   DcmTimeTagIndex
 ACCESS   read-only –-This object is not intended to be accessed,
                    -- the SMIC compiler won’t allow all objects of
                    -- a table to be defined as ‘non-accessible’,
                    -- so this object was set to be ‘read-only’.
 STATUS   mandatory
 DESCRIPTION
 "Defines the time at which the specified array parameter change occurred.
The value of this object follows the ‘controller-localTime’ setup, which
specifies the epoch since Midnight January 1, 1970."
::= {dcmAPCEntry 1}

2.8.27.2   Array Number
dcmAPCArrNum OBJECT-TYPE
 SYNTAX DcmArrayNum
 ACCESS   not-accessible
 STATUS   mandatory



                                                                                  

                                                                                        
                                                                                       



 DESCRIPTION
 "Refer to DcmArrayNum for a more detailed description."
::= {dcmAPCEntry 2}

2.8.27.3   Array Parameter Type
dcmAPCType OBJECT-TYPE
 SYNTAX DcmArrayParamType
 ACCESS   not-accessible
 STATUS   mandatory
 DESCRIPTION
 "Indicates the type of parameter associated with an array. One or more types
can be associated with an array.
Refer to DcmArrayParamType for a more detailed description."
::= {dcmAPCEntry 3}

2.8.27.4   Array Parameter Value
dcmAPCValue OBJECT-TYPE
 SYNTAX   DcmArrayParamValue
 ACCESS   not-accessible
 STATUS   mandatory
 DESCRIPTION
 "Indicates the value associated with a particular array parameter type as
specified by the dcmAPCType column.  Refer to DcmArrayParamValue for a more
detailed description."
::= {dcmAPCEntry 4}

2.8.27.5   Array Parameter FileName Pointer
dcmAPCFileName OBJECT-TYPE
 SYNTAX   DcmArrayParamFileName
 ACCESS   not-accessible
 STATUS   mandatory
 DESCRIPTION
 "Indicates a file name that contains the array parameter calibration
information. This column shall always be set to a NULL (using the encoding
specified by the ‘File Encoding Code’ in the ‘File Parameter Table’ for this
study) unless the value of dcmAPCType is set to ‘calFilPointer’.    Refer to
DcmArrayParamFileName for a more detailed description."
::= {dcmAPCEntry 5}

2.8.28    Logical IO Parameter Change Record Table
dcmIOPCRecTable OBJECT-TYPE
 SYNTAX   SEQUENCE OF DcmIOPCRecEntry
 ACCESS   not-accessible
 STATUS   optional
 DESCRIPTION
 "This table has been defined to specify a data structure record format for
any IO parameter changes that need to be written to the dcmDataStructureTable,
it is not accessible by the central application. The time tag column has been
defined as the index for syntax purposes only, there really are no indexes for
this table.
Since this table represents raw data, each column of this table shall be
stored in the ‘data’ column of the dcmDataStructureTable using the encoding
specified by the ‘File Encoding Code’ in the ‘File Parameter Table’ for this
study."
::= {dcmStudyDataSetup 28}

dcmIOPCRecEntry OBJECT-TYPE


                                                                                           

                      
       



 SYNTAX   DcmIOPCRecEntry
 ACCESS   not-accessible
 STATUS   mandatory
 DESCRIPTION "..."
 INDEX   {dcmIOPCTimeTag}
::= {dcmIOPCRecTable 1}

DcmIOPCRecEntry ::= SEQUENCE
{
 dcmIOPCTimeTag  DcmTimeTagIndex,
 dcmIOPCNum      DcmLogIONum,
 dcmIOPCParamTyp DcmIOParamType,
 dcmIOPCParamVal DcmIOParamValue
}

2.8.28.1   IOPC Time Tag
dcmIOPCTimeTag OBJECT-TYPE
 SYNTAX   DcmTimeTagIndex
 ACCESS   read-only –-This object is not intended to be accessed,
                     -- the SMIC compiler won’t allow all objects of
                     -- a table to be defined as ‘non-accessible’,
                     -- so this object was set to be ‘read-only’.
 STATUS   mandatory
 DESCRIPTION
 "Defines the time at which the specified logical IO parameter change
occurred. The value of this object follows the ‘controller-localTime’ setup,
which specifies the epoch since Midnight January 1, 1970."
::= {dcmIOPCRecEntry 1}

2.8.28.2   IOPC Logical IO Number
dcmIOPCNum OBJECT-TYPE
 SYNTAX DcmLogIONum
 ACCESS not-accessible
 STATUS mandatory
 DESCRIPTION
 "Refer to DcmLogIONum for description."
::= {dcmIOPCRecEntry 2}

2.8.28.3   IOPC IO Parameter Type
dcmIOPCParamTyp OBJECT-TYPE
 SYNTAX DcmIOParamType
 ACCESS not-accessible
 STATUS mandatory
 DESCRIPTION
 "Refer to DcmIOParamType for description."
::= {dcmIOPCRecEntry 3}

2.8.28.4   IOPC IO Parameter Value
dcmIOPCParamVal OBJECT-TYPE
 SYNTAX DcmIOParamValue
 ACCESS not-accessible
 STATUS mandatory
 DESCRIPTION
 "Refer to DcmIOParamValue for description."
::= {dcmIOPCRecEntry 4}

2.8.29        Log Data Record Table


                                                                                 

                                                                                     
                                                                                    



dcmLDRecTable OBJECT-TYPE
 SYNTAX   SEQUENCE OF DcmLDRecEntry
 ACCESS   not-accessible
 STATUS   optional
 DESCRIPTION
 "This table has been defined to specify a data structure record format for
any log data that need to be written to the dcmDataStructureTable, it is not
accessible by the central application. The time tag column has been defined
as the index for syntax purposes only, there really are no indexes for this
table.
Since this table represents raw data, each column of this table shall be
stored in the ‘data’ column of the dcmDataStructureTable using the encoding
specified by the ‘File Encoding Code’ in the ‘File Parameter Table’ for this
study."
::= {dcmStudyDataSetup 29}

dcmLDRecEntry OBJECT-TYPE
 SYNTAX   DcmLDRecEntry
 ACCESS   not-accessible
 STATUS   mandatory
 DESCRIPTION "..."
 INDEX   {dcmLDTimeTag}
::= {dcmLDRecTable 1}

DcmLDRecEntry ::= SEQUENCE
{
 dcmLDTimeTag   DcmTimeTagIndex,
 dcmLDData      OCTET STRING
}

2.8.29.1   Time Tag
dcmLDTimeTag OBJECT-TYPE
 SYNTAX   DcmTimeTagIndex
 ACCESS   read-only –-This object is not intended to be accessed,
                    -- the SMIC compiler won’t allow all objects of
                    -- a table to be defined as ‘non-accessible’,
                    -- so this object was set to be ‘read-only’.
 STATUS   mandatory
 DESCRIPTION
 "Defines the time at which the specified data log occurred.      The value of
this object follows the ‘controller-localTime’ setup, which specifies the
epoch since Midnight January 1, 1970."
::= {dcmLDRecEntry 1}

2.8.29.2   Log Data
dcmLDData OBJECT-TYPE
 SYNTAX   OCTET STRING
 ACCESS   not-accessible
 STATUS   mandatory
 DESCRIPTION
 "This field contains the actual log data that was written to the data file as
an octet string with no encoding."
::= {dcmLDRecEntry 2}

2.8.30    Data Structure Table
dcmDataStructureTable OBJECT-TYPE
 SYNTAX   SEQUENCE OF DcmDataStructureEntry



                                                                                        

                      
       



 ACCESS   not-accessible
 STATUS   optional
 DESCRIPTION
 "This is a doubly-indexed table. It defines how the data for each type of
study (binned, pvr, event) shall be stored within the data files. This table
is not accessible to any application.      It’s purpose is to define a data
structure for decoding purposes within the data files. The 2nd index is used
as a count (sequence number) associated with the Data Structure Table. When
the application is decoding the data, it can use the 2nd index to verify if
the data file contains all of the data packets for a specified study (2nd
index is sequential with no missing numbers for the specified study)."
::= {dcmStudyDataSetup 30}

dcmDataStructureEntry OBJECT-TYPE
 SYNTAX   DcmDataStructureEntry
 ACCESS   not-accessible
 STATUS   mandatory
 DESCRIPTION "..."
 INDEX {dcmDSStudyNum, dcmDataStrucIndex}
::= {dcmDataStructureTable 1}

DcmDataStructureEntry ::= SEQUENCE
 {
  dcmDSStudyNum     DcmStudyNum,
  dcmDataStrucIndex INTEGER,
  dcmStartTime      Counter,
  dcmEndTime        Counter,
  dcmDataNumRecords INTEGER,
  dcmDataEncoding   INTEGER,
  dcmData           OCTET STRING
 }

2.8.30.1   Study Number
dcmDSStudyNum OBJECT-TYPE
 SYNTAX DcmStudyNum
 ACCESS   read-only –-This object is not intended to be accessed,
                    -- the SMIC compiler won’t allow all objects of
                    -- a table to be defined as ‘non-accessible’,
                    -- so this object was set to be ‘read-only’.
 STATUS mandatory
 DESCRIPTION
 "Indicates the first index into this table. It represents a unique number for
each study that is defined within the device in the dcmStudyConfigTable.
Refer to DcmStudyConfig for more detail."
::= {dcmDataStructureEntry 1}

2.8.30.2   Data Structure Table Index
dcmDataStrucIndex OBJECT-TYPE
 SYNTAX INTEGER (1..255)
 ACCESS not-accessible
 STATUS mandatory
 DESCRIPTION
 "Indicates the second index into this table. The 2nd index is used as a
count (sequence number) associated with the Data Structure Table. When the
application is decoding the data, it can use the 2nd index to verify if the
data file contains all of the data packets (2nd index is sequential with no
missing numbers)."



                                                                                  

                                                                                        
                                                                                       



::= {dcmDataStructureEntry 2}

2.8.30.3   Start time associated with the data in this packet
dcmStartTime OBJECT-TYPE
 SYNTAX Counter
 ACCESS not-accessible
 STATUS mandatory
 DESCRIPTION
 "Defines the start date/time of the data contained within the data portion of
this packet. The value of this object follows the ‘controller-localTime’
setup, which specifies the epoch since Midnight January 1, 1970."
::= {dcmDataStructureEntry 3}

2.8.30.4   End time associated with the data in this packet
dcmEndTime OBJECT-TYPE
 SYNTAX   Counter
 ACCESS   not-accessible
 STATUS   mandatory
 DESCRIPTION
 "Defines the end date/time of the data contained within the data portion of
this packet.     The value of this object follows the ‘controller-localTime’
setup, which specifies the epoch since Midnight January 1, 1970."
::= {dcmDataStructureEntry 4}

2.8.30.5   Number of records encoded in the data section of this table
dcmDataNumRecords OBJECT-TYPE
 SYNTAX   INTEGER (0..16777215)
 ACCESS   not-accessible
 STATUS   mandatory
 DESCRIPTION
 "This field contains the number of records contained in the data section of
this table. A binned study record consists of the specified data (as defined
in the Bin Relation Table) for a single recording interval.            A Pvr study
record is defined as the grouping of the user-defined parameters (Pvr Study
Configuration Table) for each vehicle that traverses any array in the
specified study. An event record consists of the grouping of bits (as defined
in the Event Study Configuration Table and the Event To Logical IO Mapping
Table) for each IO activation associated with this study. If there is no data
associated with the specified data packet (e.g. no vehicles traversed the
sensor arrays during that time period), the number of records field shall be
set to 0 and the data field shall be set to an OCTET STRING of length 0."
::= {dcmDataStructureEntry 5}

2.8.30.6    Data Encoding Code
dcmDataEncoding OBJECT-TYPE
 SYNTAX    INTEGER
 {
   other (1),
   noEncoding (2)
 }
 ACCESS    not-accessible
 STATUS    mandatory
 DESCRIPTION
 "This field contains a code which specifies the encoding of the data packet.
Currently no encodings have been defined.        This field is for future
enhancements (e.g. data compression)."
::= {dcmDataStructureEntry 6}


                                                                                           

                      
       




2.8.30.7   Collected Data
dcmData OBJECT-TYPE
 SYNTAX   OCTET STRING
 ACCESS   not-accessible
 STATUS   mandatory
 DESCRIPTION
 "This field contains the actual data that was recorded for this study.
Although it is defined as an Octet String, it represents binary data.  The
type of data encoded in this column is identified in the configured study
mapped to this row of this table (refer to Study Configuration Table).

Binned data shall store a single octet value as the first byte in this field
which indicates the number of octets used to store each bin count. The number
and order of the bin counts stored are defined by the Binned Study
Configuration Table (refer to Binned Data Bins Ordering C.3.1.8).         Each
recording interval is considered a binned data record.     One or more binned
data records may be stored in this field as specified by the number of records
field in this row of this table.

PVR data shall be stored as defined by the PVR Study Configuration Table. The
PVR data (as defined in the PVR Study Configuration Table) associated with
each vehicle is considered a vehicle record. One or more vehicle records may
be stored in this field as specified by the number of records field in this
row of this table.

Event data shall be stored as defined by the Event Study Configuration Table.
Each sensor event shall be considered an event record.     One or more event
records may be stored in this field as specified by the number of records
field in this row of this table.

ArrayParam data shall be stored as defined by the Array Parameter Change
Record Table.   It represents Array Parameters (refer to the Array Parameter
Table) that have been changed in the dcm device either manually or
automatically. One or more Array Parameter Change Records may be stored in
this field as specified by the number of records field in this row.

LogicalIOParam data shall be stored as defined by the Logical IO Parameter
Change Record Table. It represents Logical IO Parameters (refer to the Logical
IO Parameter Table) that have been changed in the dcm device either manually
or automatically. One or more Logical IO Parameter Change Records may be
stored in this field as specified by the number of records field in this row.

LogData data shall be stored as defined by the Log Data Record Table.      It
represents information (as an octet string) with a time tag which the dcm
device has written to the data file. One or more Log Records may be stored in
this field as specified by the number of records field in this row.

Refer to Annex C.3.1 for an example of Binned Record Data encoding, Annex
C.3.2 for an example of PVR Record Data encoding and Annex C.3.3 for an
example of Event Record Data encoding. This packet may contain data for one or
more recording intervals.    The length of the entire data section shall be
encoded   as the length field of this Octet String.      If there is no data
associated with the specified data packet (e.g. no vehicles traversed the
sensor arrays during that time period), the number of records field shall be
set to 0 and an ASN.1 NULL shall be placed in the data field."
::= {dcmDataStructureEntry 7}




                                                                                  

                                                                                     
                                                                                    



2.9   FILE SETUP NODE
--dcm File Configuration Node
dcmFileConfig OBJECT IDENTIFIER ::= {dcm 7}
-- This node is an identifier used to group all objects for configuring of the
-- file parameters that are common to data collection and monitoring
-- devices.

2.9.1     Current Number Of File Structures
dcmNumFileStructures     OBJECT-TYPE
 SYNTAX INTEGER (0..255)
 ACCESS read-only
 STATUS optional
 DESCRIPTION
 "indicates the current number of defined      file   structures     in   the     File
Structure Table."
::= {dcmFileConfig 1}

2.9.2     Maximum Number Of File Structure Table Rows
dcmFSTMaxNumRows OBJECT-TYPE
 SYNTAX DcmMaxNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the maximum number of rows allowed for the File Structure Table."
::= {dcmFileConfig 2}

2.9.3     Current Number Of File Structure Table Rows
dcmFSTCurNumRows OBJECT-TYPE
 SYNTAX DcmCurNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the current number of rows existing in the File Structure Table."
::= {dcmFileConfig 3}

2.9.4     File Structure Table
dcmFileStrucTable OBJECT-TYPE
 SYNTAX SEQUENCE OF DcmFileStrucEntry
 ACCESS not-accessible
 STATUS optional
 DESCRIPTION
 "This is a doubly-indexed table. It defines which items shall be stored in
the data files. By default, the dcm MIB Version Number object shall always be
included as the first object. The device shall also include the required data
packets (encoded as Data Structure Tables) for the included studies.       The
objects specified in this table shall be stored in the data file in the same
order as specified in this table. There may be other objects included in the
header information section that have not been specified in this table, however
these object can be skipped over by using the length field of the OID and the
length field of the associated Value."
::= {dcmFileConfig 4}

dcmFileStrucEntry OBJECT-TYPE
 SYNTAX DcmFileStrucEntry
 ACCESS not-accessible
 STATUS mandatory


                                                                                        

                      
       



 DESCRIPTION "..."
 INDEX {dcmFSFileStrucNum, dcmFileStrucIndex}
::= {dcmFileStrucTable 1}

DcmFileStrucEntry ::= SEQUENCE
{
 dcmFSFileStrucNum    DcmFileStrucNum,
 dcmFileStrucIndex    INTEGER,
 dcmFileStrucOID      OBJECT IDENTIFIER,
 dcmFileStrucRowAdmin DcmRowStatus
}

2.9.4.1    File Structure Number
dcmFSFileStrucNum OBJECT-TYPE
 SYNTAX   DcmFileStrucNum
 ACCESS   read-only
 STATUS   mandatory
 DESCRIPTION
 "Indicates the first index into this table. This is the number assigned to
the defined file structure. It is highly recommended that the application try
to keep this number sequential (reuse numbers that have been deleted)."
::= {dcmFileStrucEntry 1}

2.9.4.2    File Structure Index
dcmFileStrucIndex OBJECT-TYPE
 SYNTAX INTEGER (1..255)
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the second index into this table. A 2nd index is required to
allow specifying multiple parameters to store for each File Structure Number."
::= {dcmFileStrucEntry 2}

2.9.4.3    File Structure Table OID
dcmFileStrucOID OBJECT-TYPE
 SYNTAX   OBJECT IDENTIFIER
 ACCESS   read-write
 STATUS   mandatory
 DESCRIPTION
 "This field contains the OID of the object/table to include in the data file.
All OID’s shall be specified using the full OID address.         Relative OID
addressing is not allowed."
::= {dcmFileStrucEntry 3}

2.9.4.4    File Structure Table Row Admin
dcmFileStrucRowAdmin OBJECT-TYPE
 SYNTAX   DcmRowStatus
 ACCESS   read-write
 STATUS   mandatory
 DESCRIPTION
 "allows management of the parameters used to configure an event study (this
row of this table). The SYNTAX definition allows to create, delete, disable,
or edit the row."
::= {dcmFileStrucEntry 4}




                                                                                  

                                                                                     
                                                                                    



2.9.5     Maximum Number Of File Parameter Table Rows
dcmFPTMaxNumRows OBJECT-TYPE
 SYNTAX DcmMaxNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the maximum number of rows allowed for the File Parameter Table."
::= {dcmFileConfig 5}

2.9.6     Current Number Of File Parameter Table Rows
dcmFPTCurNumRows OBJECT-TYPE
 SYNTAX DcmCurNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the current number of rows existing in the Monitor Enable Table."
::= {dcmFileConfig 6}

2.9.7     File Parameter Table
dcmFPTable OBJECT-TYPE
 SYNTAX SEQUENCE OF DcmFPEntry
 ACCESS not-accessible
 STATUS optional
 DESCRIPTION
 "This is a doubly-indexed table.    It links a defined study from the Study
Configuration Table to a user-defined file format in the File Structure Table
through the Study File Index in the Study Configuration Table.          It is
recommended to include this table in the data file as one of the first objects
in the data file (specify this OID in the Data File Structure Table as one of
the first OID’s to store) to allow determining what File Encoding was used
(BER or OER) and if Relative Addressing has been enabled.      If the defined
study is deleted from the Study Configuration Table, the entry for that study
shall be automatically deleted from this table by the device."
::= {dcmFileConfig 7}

dcmFPEntry OBJECT-TYPE
 SYNTAX DcmFPEntry
 ACCESS not-accessible
 STATUS mandatory
 DESCRIPTION "..."
 INDEX {dcmFPFileStudyIndex, dcmFPFileStrucNum}
::= {dcmFPTable 1}

DcmFPEntry ::= SEQUENCE
{
 dcmFPFileStudyIndex            DcmFileStudyIndex,
 dcmFPFileStrucNum              DcmFileStrucNum,
 dcmFPRecInt                    INTEGER,
 dcmFPFileFreq                  INTEGER,
 dcmFPLogicalIONumber           DcmLogIONum,
 dcmFPRelativeAddrFlag          INTEGER,
 dcmFPEncodingCode              INTEGER,
 dcmFPRowAdmin                  DcmRowStatus
}

2.9.7.1      File Study Index




                                                                                        

                      
       



dcmFPFileStudyIndex OBJECT-TYPE
 SYNTAX   DcmFileStudyIndex
 ACCESS   read-only
 STATUS   mandatory
 DESCRIPTION
 "Indicates the first index into this table. It defines the file structure
number within the File Structure Table (non-zero values). A value of zero (0)
indicates that no data shall be recorded and the study is to be used for
Monitor Modes."
::= {dcmFPEntry 1}

2.9.7.2    File Structure Number
dcmFPFileStrucNum OBJECT-TYPE
 SYNTAX   DcmFileStrucNum
 ACCESS   read-only
 STATUS   mandatory
 DESCRIPTION
 "Indicates the second index into this table. This is the number assigned to
the defined file structure. It is highly recommended that the application try
to keep this number sequential (reuse numbers that have been deleted)."
::= {dcmFPEntry 2}

2.9.7.3    File Recording Interval
dcmFPRecInt OBJECT-TYPE
 SYNTAX   INTEGER (1..16777215)
 ACCESS   read-write
 STATUS   mandatory
 DESCRIPTION
 "This defines the recording interval (in seconds) for the specified study. A
new row shall be created in the Data Structure Table for each recording
interval. For example, if recording a binned study in 15 minute intervals
(15*60 seconds), then each row of the Data Structure Table would represent 15
minutes worth of binned data. The same would be true for pvr data and event
data."
::= {dcmFPEntry 3}

2.9.7.4     File Recording Frequency
dcmFPFileFreq OBJECT-TYPE
 SYNTAX INTEGER
 {
   other (1),
   eachRecInt (2),
   hourly (3),
   daily (4),
   midnight (5),
   weekly (6),
   monthly (7),
   continuous (8)
 }
 ACCESS    read-write
 STATUS    mandatory
 DESCRIPTION
 "Indicates how frequently a new data file shall be created for the specified
study. The values are:
- other = not defined below
- eachRecInt = Creates a new data file each recording interval.




                                                                                 

                                                                                     
                                                                                    



- hourly = Creates a new data file each hour (the recording interval must be
set to 60 minutes or less to use this option).
- daily = Creates a new data file each day at the specified start time for
this study.
- midnight = Creates a new data file each day at midnight.
- weekly = Creates a new data file each week at the specified start day of
week for this study.
- monthly = Creates a new data file at the start of each calendar month.
- continuous = Creates only one data file. All data shall be appended to the
same file. The only way to close this data file is to disable the study."
::= {dcmFPEntry 4}

2.9.7.5    FP Logical IO Number
dcmFPLogicalIONumber OBJECT-TYPE
 SYNTAX   DcmLogIONum
 ACCESS   read-write
 STATUS   mandatory
 DESCRIPTION
 "This column is used in this table to link a file to a storage memory media
(which will have been assigned a logical IO number in the Physical To Logical
Mapping Table.     It defines where the data files for this study shall be
stored."
::= {dcmFPEntry 5}

2.9.7.6     Relative Address Flag
dcmFPRelativeAddrFlag OBJECT-TYPE
 SYNTAX    INTEGER
 {
   disabled (1),
   enabled (2)
 }
 ACCESS    read-write
 STATUS    mandatory
 DESCRIPTION
 "This column is used to enable/disable the use of relative OID addressing in
the specified data file.          Setting this to a 1 shall inhibit the use of
relative OID addressing for this data file. Setting this to a 2 shall enable
relative OID addressing for this data file. An application can only enable
this feature. It has no control as to where and how often (within this data
file) that the device shall use this option (see dcmRelativeAddress object)."
::= {dcmFPEntry 6}

2.9.7.7     File Encoding Code
dcmFPEncodingCode OBJECT-TYPE
 SYNTAX    INTEGER
 {
   other (1),
   berEncoding (2),
   oerEncoding (3)
 }
 ACCESS    read-write
 STATUS    mandatory
 DESCRIPTION
 "This column is used to enable various encoding schemes for the data files.
The values are:
- other = not defined below




                                                                                        

                      
        



- berEncoding = All objects shall be stored within this data file using BER
encoding of the ASN.1 object definition.
- oerEncoding = All objects shall be stored within this data file using OER
(Octet Encoding Rules, as defined in NTCIP 1102) encoding of the ASN.1 object
definition."
::= {dcmFPEntry 7}

2.9.7.8    File Parameter Table Row Admin
dcmFPRowAdmin OBJECT-TYPE
 SYNTAX   DcmRowStatus
 ACCESS   read-write
 STATUS   mandatory
 DESCRIPTION
 "allows management of the parameters used to configure an event study (this
row of this table). The SYNTAX definition allows to create, delete, disable,
or edit the row."
::= {dcmFPEntry 8}

2.9.8     Data File Integrity Object
dcmDFIntegrity OBJECT-TYPE
 SYNTAX   INTEGER (1..65535)
 ACCESS   read-only
 STATUS   optional
 DESCRIPTION
 "The purpose of this object is to allow the device to calculate a CRC16 check
on the data file for integrity and to store this within the data file (if it
has been specified in the File Structure Table). The check shall be based on
all bytes of the data file except for this object. This object is read-only
and cannot be manipulated by the application."
::= {dcmFileConfig 8}


2.9.9     Maximum Number Of File Directory Structure Table Rows
dcmFDSTMaxNumRows OBJECT-TYPE
 SYNTAX DcmMaxNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the maximum number of rows allowed for                  the   File   Directory
Structure Table."
::= {dcmFileConfig 9}

2.9.10    Current Number Of File Directory Structure Table Rows
dcmFDSTCurNumRows OBJECT-TYPE
 SYNTAX DcmCurNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the current number of rows existing in                  the   File   Directory
Structure Table."
::= {dcmFileConfig 10}

2.9.11    File Directory Structure Table
dcmFileDirStrucTable OBJECT-TYPE
 SYNTAX SEQUENCE OF DcmFileDirStrucEntry
 ACCESS not-accessible



                                                                                            

                                                                                     
                                                                                    



 STATUS optional
 DESCRIPTION
 "This is a doubly-indexed table. It is required to provide a consistent
directory listing of data files contained within the device. The FTP directory
listing command may not provide a consistent output listing of the file fields
between the various FTP implementations."
::= {dcmFileConfig 11}

dcmFileDirStrucEntry OBJECT-TYPE
 SYNTAX DcmFileDirStrucEntry
 ACCESS not-accessible
 STATUS mandatory
 DESCRIPTION "..."
 INDEX {dcmFDSLogIOIndex, dcmFDSFileNumber}
::= {dcmFileDirStrucTable 1}

DcmFileDirStrucEntry ::= SEQUENCE
{
 dcmFDSLogIOIndex   INTEGER,
 dcmFDSFileNumber   INTEGER,
 dcmFDSFileName     OCTET STRING,
 dcmFDSStartTime    Counter,
 dcmFDSEndTime      Counter,
 dcmFDSFileSize     INTEGER,
 dcmFDSDownloadFlag INTEGER,
 dcmFDSOpenFlag     INTEGER
}

2.9.11.1   Logical IO Number Index
dcmFDSLogIOIndex OBJECT-TYPE
 SYNTAX   INTEGER (1..255)
 ACCESS   read-only
 STATUS   mandatory
 DESCRIPTION
 "The first index is the logical IO number assigned to the memory media in
which the data file is stored. The application should identify which logical
IO numbers are assigned to data storage media (downloading the Physical to
Logical IO Mapping Table) and use those logical IO numbers as the first index
into the File Directory Structure Table, or the application can perform a
getnext on the File Directory Structure Table to get the full listing of
existing files."
::= {dcmFileDirStrucEntry 1}

2.9.11.2   File Number
dcmFDSFileNumber OBJECT-TYPE
 SYNTAX INTEGER (1..65535)
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the second index into this table. This index is required to allow
specifying multiple data files for each Logical IO storage media."
::= {dcmFileDirStrucEntry 2}

2.9.11.3   File Name
dcmFDSFileName OBJECT-TYPE
 SYNTAX   OCTET STRING
 ACCESS   read-only



                                                                                        

                      
        



 STATUS   mandatory
 DESCRIPTION
 "This field contains the name of the data file (including any directory
paths). This name can be used in conjunction with FTP to download this data
file."
::= {dcmFileDirStrucEntry 3}

2.9.11.4   Start Date/Time of Data File
dcmFDSStartTime OBJECT-TYPE
 SYNTAX   Counter
 ACCESS   read-only
 STATUS   mandatory
 DESCRIPTION
 "This field contains the start date/time for the specified data file. The
value of this object follows the ‘controller-localTime’ setup, which specifies
the epoch since Midnight January 1, 1970."
::= {dcmFileDirStrucEntry 4}

2.9.11.5   End Date/Time of Data File
dcmFDSEndTime OBJECT-TYPE
 SYNTAX   Counter
 ACCESS   read-only
 STATUS   mandatory
 DESCRIPTION
 "This field contains the end date/time for the specified data file.       The
value of this object follows the ‘controller-localTime’ setup, which specifies
the epoch since Midnight January 1, 1970.     If the specified file is still
opened, the end date/time shall indicate the devices current date/time."
::= {dcmFileDirStrucEntry 5}

2.9.11.6   File Size
dcmFDSFileSize OBJECT-TYPE
 SYNTAX   INTEGER
 ACCESS   read-write
 STATUS   mandatory
 DESCRIPTION
 "This field is used to identify the size (in octets) of the data file. If
the file is still open, the file size shall indicate the current size of the
file."
::= {dcmFileDirStrucEntry 6}

2.9.11.7   File Download Flag
dcmFDSDownloadFlag OBJECT-TYPE
 SYNTAX   INTEGER (1..255)
 ACCESS   read-write
 STATUS   mandatory
 DESCRIPTION
 "This field is used to allow the application to determine if the specified
file has already been downloaded.    A file that has not been downloaded is
considered to be ‘new’. It is up to the application as to how to process this
field. It could simply use a 1 to indicate the data file was downloaded or it
could treat this field as a bitmap to allow multiple applications to download
this file as new by processing different bits within this field."
::= {dcmFileDirStrucEntry 7}

2.9.11.8       Open Flag



                                                                                  

                                                                                     
                                                                                    



dcmFDSOpenFlag OBJECT-TYPE
 SYNTAX   INTEGER
 {
  fileOpen       (1),
  fileClosed     (2),
  fileLocked     (3),
  fileOpenLocked (4)
 }
 ACCESS   read-only
 STATUS   mandatory
 DESCRIPTION
 "This field is used to allow the application to determine if the specified
file is currently open or if it has been closed by the device.      The values
are:
-fileOpen = data file is currently open (still being written to).
-fileClosed = data file has been closed by the device.
-fileLocked = data file is locked by the device, it cannot be downloaded at
this time.
-fileOpenLocked = data file is currently open and cannot be downloaded at this
time (for example, may be writing to a FLASH storage media)"
::= {dcmFileDirStrucEntry 8}

2.10 ERROR LOGGING NODE
--DCM Error Node
dcmErrors OBJECT IDENTIFIER ::= {dcm 8}
-- This node is an identifier used to group all errors that are common to data
-- collection and monitoring devices.

2.10.1    Maximum Number Of Error Code Table Rows
dcmECTMaxNumRows OBJECT-TYPE
 SYNTAX DcmMaxNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the maximum number of rows allowed for the Error Code Table."
::= {dcmErrors 1}

2.10.2    Current Number Of Error Code Table Rows
dcmECTCurNumRows OBJECT-TYPE
 SYNTAX DcmCurNumRows
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the current number of rows existing in the Error Code Table."
::= {dcmErrors 2}

2.10.3    Dcm Error Code Table
dcmErrCodeTable OBJECT-TYPE
 SYNTAX SEQUENCE OF DcmErrCodeEntry
 ACCESS not-accessible
 STATUS optional
 DESCRIPTION
 "This table is a read-only table that is updated by the device after each set
operation. This table has a single general index. The index must be assigned
sequentially by the device. The number of rows present are dependent on the
results of the previous operation. If the last set operation resulted in no



                                                                                        

                      
        



errors, then there shall be no rows configured in this table. There can be
multiple rows set (one for each item in error) or there may only be one row
set which would contain the OID of the first object that was in error, this
choice is implementation-specific. Each row identifies the type of error and
links it to the OID of the object that caused the dcm error. This table is NOT
used to report communications protocol errors, those are handled as part of
the communications protocols.   All existing rows shall be cleared out each
time the device updates this table.    The rows shall always indicate errors
based on the last time this table was updated and not show historical errors."
::= {dcmErrors 3}

dcmErrCodeEntry OBJECT-TYPE
 SYNTAX   DcmErrCodeEntry
 ACCESS   not-accessible
 STATUS   mandatory
 DESCRIPTION "..."
 INDEX    {dcmErrCodeIndex}
::= {dcmErrCodeTable 1}

DcmErrCodeEntry ::= SEQUENCE
{
 dcmErrCodeIndex INTEGER,
 dcmErrCodeOID   OBJECT IDENTIFIER,
 dcmErrCode      INTEGER
}

2.10.3.1   Error Code Index
dcmErrCodeIndex OBJECT-TYPE
 SYNTAX INTEGER (1..255)
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "indicates the only index into this table.   It must be assigned sequentially
by the device."
::= {dcmErrCodeEntry 1}

2.10.3.2   Error Code Object Identifier
dcmErrCodeOID OBJECT-TYPE
 SYNTAX OBJECT IDENTIFIER
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "This value points to the OID responsible for generating the error. The OID
must be specified using full OID addressing. Relative OID addressing is not
allowed."
::= {dcmErrCodeEntry 2}

2.10.3.3    Dcm Error Code
dcmErrCode OBJECT-TYPE
 SYNTAX INTEGER
 {
   other (1),
   noError (2),
   notValidAtThisTime (3),
   validationFailed (4),
   optionNotSupported (5),
   outOfRange (6),



                                                                                   

                                                                                     
                                                                                    



  invalidOption (7),
  notAllowedPrimeRec (8),
  lockedOut (9),
  exceededMaxLength (10),
  exceededMaxNumberOfAllowedOccurrences (11),
  exceededMaxNumberOfRows (12),
  readOnly (13)
 }
 ACCESS read-only
 STATUS mandatory
 DESCRIPTION
 "Indicates the type of error that was detected for the object referenced by
dcmErrCodeOID. The values are:
1=other
2=noError, the operation resulted in no error for the specified object.
3=notValidAtThisTime, try to set a variable to a value that under other
circumstances could be valid, but is not valid at this time (e.g. try to set
RowStatus to createAndWait when it is currently set to active).
4=validationFailed, validation of a study failed.
5=optionNotSupported, (e.g. try to set an enumeration value that is not
supported by the device).
6=out of range, try to set an object to a value that is out of range.
7=invalidOption (e.g. try to do axle class using standard loop loop sensor
array).
8=NotAllowedPrimeRec, can’t modify this object while primed or recording
9=lockedOut, objects are currently locked (e.g. object is being modified by
another application).
10=exceededMaxLength, try to set an octet string to a length greater than is
supported.
11=exceededMaxNumberOfAllowedOccurrences for this index (e.g. try to set more
than the allowed number of cal factors for an IO).
12=exceededMaxNumberOfRows, allowed for this table.
13=readOnly, (e.g. try to set dataStorageMediaAvailable, this object value is
read-only)."
::= {dcmErrCodeEntry 3}

2.11 DCM RELATIVE ADDRESS OID OBJECT
dcmRelativeAddrOID OBJECT-TYPE
 SYNTAX   OBJECT IDENTIFIER
 ACCESS   read-write
 STATUS   optional
 DESCRIPTION
 "Indicates the OID address which shall be referenced by any object in the
specified data file if relative OID’s have been enabled (through the File
Parameter Table). The last number indicated in the OID value shall not be
repeated in the relative OID’s. This object has been included to reduce
overhead relative to OID’s when specified in data files. This object shall
not be used to shorten OID’s within SNMP messages. The device shall return an
‘out of range’ error if the application attempts to set this object to an OID
below where this object resides.    This will prevent a situation where this
object cannot be accessed anymore. An application can only enable the usage
of this object within specified data files.        Once enabled, it will be
determined by the device where and how often to use it to optimize the storage
requirements of OID’s. This object may be used multiple times within the same
data file by the device to change the relative addressing of the OID’s in
order to optimize storage."
::= {dcm 9}



                                                                                        

                      
        



2.12 DCM MIB VERSION NUMBER
dcmMibVersionNumber OBJECT-TYPE
 SYNTAX INTEGER (100..65535)
 ACCESS read-only
 STATUS optional
 DESCRIPTION
 "Contains the version number of the dcm MIB implemented in this device,
100=version 1.00."
::= {dcm 10}