-- OIDref derived MIB transcription. Original PDF: https://www.ite.org/ITEORG/assets/File/Standards/1201v4-0-0.pdf -- Publisher front matter and notices follow as comments. -- A Joint Standard of AASHTO, ITE, and NEMA -- -- -- -- -- NTCIP 1201 v4.0.0 -- -- -- National Transportation -- Communications for ITS Protocol -- Global Object (GO) Definitions -- -- -- Published June 2025 -- -- -- -- -- Published by: -- -- American Association of State Highway and Transportation Officials (AASHTO) -- 555 12th Street, N.W., Suite 1000 -- Washington, D.C. 20004 -- -- Institute of Transportation Engineers (ITE) -- 1627 I Street, N.W., Suite 550 -- Washington, D.C. 20006 -- -- National Electrical Manufacturers Association (NEMA) -- 1300 17th Street N, #900 -- Arlington, VA 22209 -- -- -- --  2025 AASHTO / ITE / NEMA. All rights reserved. -- -- -- NOTICES -- -- Copyright Notice -- -- © 1997, 1999, 2005, 2011, 2025 by the American Association of State Highway and Transportation -- Of f icials (AASHTO), the Institute of Transportation Engineers (ITE), and the National Electrical -- Manuf acturers Association (NEMA). All intellectual property rights, including, but not limited to, the rights -- of reproduction, translation, and display are reserved under the laws of the United States of America, the -- Universal Copyright Convention, the Berne Convention, and the International and Pan American -- Copyright Conventions. Except as licensed or permitted, you may not copy these materials without prior -- written permission f rom AASHTO, ITE, or NEMA. Use of these materials does not grant any rights of -- ownership or claim of copyright. -- -- Visit www.ntcip.org For additional copyright inf ormation, instructions on requesting reprints of excerpts, -- and requests f or reproduction d the beyond the permissions granted below, visit www.ntcip.org. -- -- PDF File License Agreement -- -- To the extent that these materials are distributed by AASHTO / ITE / NEMA in the f orm of an Adobe® -- Portable Document Format (PDF) electronic f ile (the PDF f ile), AASHTO / ITE / NEMA authorizes each -- registered user to view, download, copy, or print the f ile f rom the authorized website, subject to the terms -- and conditions of this license agreement: -- -- a) You may download one copy of the PDF f ile f or personal, noncommercial, and intraorganizational -- use only. -- b) Ownership of the PDF f ile is not transf erred to you; you are licensed to use the PDF f ile. -- c) You may make one additional electronic copy of the PDF f ile, such as to a secondary hard drive -- or CD. -- d) You agree not to copy, distribute, or transf er the PDF f ile f rom that media to any other electronic -- media or device. -- e) You may print one paper copy of the PDF f ile. -- f ) You may make one paper reproduction of the printed copy. -- g) Any permitted copies must retain the copyright notice and all proprietary notices. -- h) The PDF f ile license does not include (1) resale of the PDF f ile or copies, (2) republishing the -- content in compendiums or anthologies, (3) publishing excerpts in commercial publications or -- works f or hire, (4) editing or modif ication of the PDF f ile except those portions as permitted, (5) -- posting on network servers or distribution by e- mail or f rom electronic storage devices, and (6) -- translation to other languages or conversion to other electronic f ormats. -- i) Other use of the PDF f ile and printed copy requires express, prior written consent. -- -- -- Data Dictionary and MIB Distribution Permission -- -- To the extent that these materials are distributed by AASHTO / ITE / NEMA in the f orm of a Data -- Dictionary ("DD") or Management Inf ormation Base ("MIB"), AASHTO / ITE / NEMA extend the f ollowing -- permission: -- -- You may make or distribute unlimited copies, in part or f ull, of the DD or MIB, including copies f or -- commercial distribution, provided that: -- -- 1. Each copy you make or distribute includes the citation "From NTCIP 0000 [insert the standard -- number]. Copyright by AASHTO / ITE / NEMA. Used by permission." -- 2. The copies are not edited f rom the published version of this document. -- -- These materials are delivered "AS IS," without any warranties regarding their use or perf ormance. -- -- AASHTO / ITE / NEMA and their suppliers do not warrant the performance or results you may -- obtain by using these materials. AASHTO / ITE / NEMA and their suppliers make no warranties, -- express or implied, as to noninfringement of third-party rights, merchantability, or fitness for any -- particular purpose. In no event will AASHTO / ITE / NEMA or their suppliers be liable to you or any -- third party for any claim or for any consequential, incidental or special damages, including any -- lost profits or lost savings, arising from your reproduction or use of these materials, even if an -- AASHTO / ITE / NEMA representative has been advised of the possibility of such damages. -- -- Some states or jurisdictions do not allow the exclusion or limitation of incidental, consequential, or special -- damages, or the exclusion of implied warranties, so the above limitations may not apply to a given user. -- -- Use of these materials does not constitute an endorsement or af f iliation by or between AASHTO, ITE, or -- NEMA and the user, the user's company, or the products and services of the user's company. -- -- If the user is unwilling to accept the f oregoing restrictions, he or she should immediately return these -- materials. -- -- Content and Liability Disclaimer -- -- The inf ormation in this publication was considered technically sound by the consensus of persons -- engaged in the development and approval of the document at the time it was developed. However, -- consensus does not imply unanimous agreement. among every person participating in the development -- of this document. -- -- AASHTO, ITE, and NEMA standards and guideline publications, of which the document contained herein -- is one, are developed through a voluntary consensus standards development process. This process -- brings together volunteers and seeks out the views of persons who have an interest in the topic covered -- by this publication. While AASHTO, ITE, and NEMA administer the process and establish rules to -- promote f airness in the development of consensus, they do not write the document and they do not -- independently test, evaluate, or verif y the accuracy or completeness of any inf ormation or the soundness -- of any judgments contained in their standards and guideline publications. -- -- AASHTO, ITE, and NEMA disclaim liability f or any personal injury, property, or other damages of any -- nature whatsoever, whether special, indirect, consequential, or compensatory, directly or indirectly -- resulting f rom the publication, use of , application, or reliance on this document. AASHTO, ITE, and NEMA -- disclaim and make no guaranty or warranty, express or implied, as to the accuracy or completeness of -- any inf ormation published herein and disclaims and makes no warranty that the inf ormation in this -- document will f ulf ill any of your purposes or needs. AASHTO, ITE, and NEMA do not undertake to -- guarantee the perf ormance of any individual manuf acturer or seller's products or services by virtue of this -- standard or guide. -- -- In publishing and making this document available, AASHTO, ITE, and NEMA are not undertaking to -- render prof essional or other services f or or on behalf of any person or entity, nor are AASHTO, ITE, and -- NEMA undertaking to perf orm any duty owed by any person or entity to someone else. Anyone using this -- document should rely on his or her own independent judgment or, as appropriate, seek the advice of a -- competent prof essional in determining the exercise of reasonable care in any given circumstance. -- Inf ormation and other standards on the topic covered by this publication may be available f rom other -- sources, which the user may wish to consult f or additional views or inf ormation not covered by this -- publication. -- -- AASHTO, ITE, and NEMA have no power, nor do they undertake to police or enf orce compliance with the -- contents of this document. AASHTO, ITE, and NEMA do not certif y, test, or inspect products, designs, or -- -- installations f or saf ety or health purposes. Any certif ication or other statement of compliance with any -- health or saf ety-related inf ormation in this document shall not be attributable to AASHTO, ITE, or NEMA -- and is solely the responsibility of the certif ier or maker of the statement. -- -- Trademark Notice -- -- NTCIP is a trademark of AASHTO / ITE / NEMA. All other trademarks mentioned in this standard belong -- to their respective owners. -- -- -- NTCIP 1201 v4.0.0 -- Page i -- -- -- -- ACKNOWLEDGEMENTS -- -- NTCIP 1201 v04 was prepared by the NTCIP Base Standards and Prof iles Working Group (BSP2 WG), a -- subdivision of the Joint Committee on the NTCIP. This committee operates under a Memorandum of -- Understanding among the American Association of State Highway and Transportation Of f icials -- (AASHTO), the Institute of Transportation Engineers (ITE), and the National Electrical Manuf acturers -- Association (NEMA). The Joint Committee on the NTCIP consists of six representatives f rom each -- standards development organization (SDO) and provides guidance f or NTCIP development. -- -- When this document was prepared, the f ollowing individuals were members of BSP2 WG: -- -- 1. Doug Crawf ord (Chair) 8. Robert Lopes -- 2. Steve Bostrom 9. Alex Mousadi -- 3. Wolf gang Buckel 10. Satya Muthuswamy -- 4. Michael Forbis 11. Bob Rausch -- 5. Joe Gorman 12. Rodney Schilling -- 6. Terry Haukom 13. Shea Tomsin -- 7. Patrick Leung 14. Walt Townsend -- -- -- Other individuals providing input include the f ollowing: -- -- 1. Md Ashraf Ahmed 18. Stephane Lapierre -- 2. Justin Anderson 19. Christopher Lyons -- 3. Kingsley Azubike 20. Gary Molnar -- 4. Ralph Boaz 21. Keith Patton -- 5. Russ Brookshire 22. Mahesh Pawar -- 6. Patrick Chan 23. Frank Perry -- 7. Stan Chow 24. Nu Rosenbohm -- 8. Deborah Curtis 25. Jay Schultz -- 9. Dustin DeVoe 26. Kellen Shain -- 10. Brian Doherty 27. Douglas Tarico -- 11. Edward Fok 28. Nicola Tavares -- 12. Sai Kiran Golla 29. John Thai -- 13. Jacob Grivette 30. Andrew Valdez -- 14. Mohammad Iraki 31. Kenneth Vaughn -- 15. Haydar Issa 32. Sankeer Vulupala -- 16. Denver Kruse 33. Robert White -- 17. AJ Lahiri -- -- -- In addition to the many volunteer ef f orts, recognition is also given to those organizations that supported -- the ef f orts of BSP2 WG by providing comments and f unding, including the f ollowing: -- -- 1. U.S. Department of Transportation, Research and Innovative Technology Administration -- 2. U.S. Department of Transportation, Federal Highway Administration -- 3. AECOM -- 4. Applied Inf ormation -- 5. City of Anaheim, CA -- 6. Consensus Systems Technologies -- 7. Caltrans -- 8. Daktronics -- 9. Econolite Control Products, Inc. -- 10. Florida Department of Transportation -- -- -- -- © 2025 AASHTO / ITE / NEMA Do Not Copy Without Written Permission -- -- NTCIP 1201 v4.0.0 -- Page ii -- -- 11. Georgia DOT -- 12. Kapsch -- 13. KLD Engineering -- 14. Michigan DOT -- 15. Minnesota DOT -- 16. Nevada DOT -- 17. Noblis -- 18. Parsons -- 19. Pillar Consulting -- 20. Q-Free -- 21. Siemens ITS -- 22. Signalisation Ver-Mac, Inc. -- 23. TransCore -- 24. Transport Canada -- 25. Trevilon -- 26. Washington State DOT -- 27. WSP -- -- -- -- -- Do Not Copy Without Written Permission © 2025 AASHTO / ITE / NEMA NTCIP1201-DynObjMgmt DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-IDENTITY, OBJECT-TYPE, Integer32, zeroDotZero FROM SNMPv2-SMI -- RFC 2578 TEXTUAL-CONVENTION FROM SNMPv2-TC -- RFC 2579 protocols, NtcipOwnerString FROM NTCIP8004-Transportation; dynObjMgmt MODULE-IDENTITY LAST-UPDATED "20230701145436Z" ORGANIZATION "NTCIP BSP2 WG" CONTACT-INFO "name: NTCIP Coordinator email: ntcip@nema.org postal: National Electrical Manufacturers Association 1300 North 17th Street, Suite 1752 Rosslyn, Virginia 22209-3801" DESCRIPTION " This MIB defines the SMIv2 representation of the NTCIP1103v0352-STMP MIB, which was previously defined in NTCIP 1103. This node contains management information related to dynamic objects. This node was deprecated in 2021 as a part of the NTCIP 8004v03 update because dynamic objects are a specific feature of the Simple Transportation Management Protocol (STMP), which was itself deprecated because it was deemed to provide insufficient security for modern networks. *** All objects in this MIB have been deprecated. *** 1.3.6.1.4.1.1206.4.1.3" REVISION "20230701145436Z" DESCRIPTION "NTCIP 1201 v04 - Upgraded format to SMIv2 and deprecated all objects." REVISION "201612310000Z" DESCRIPTION "NTCIP 1103 v03 - No change." REVISION "200903310000Z" DESCRIPTION "NTCIP 1103 v02 -." REVISION "199609270000Z" DESCRIPTION "NTCIP 1101 v01: Original version of these objects." ::= { protocols 3 } ConfigEntryStatus ::= TEXTUAL-CONVENTION STATUS deprecated DESCRIPTION "See Clause 5.2.4.1 of NTCIP 1103 v03 for the complete definition of this type." SYNTAX INTEGER { valid (1), underCreation (2), invalid (3) } EntryStatus ::= TEXTUAL-CONVENTION STATUS deprecated DESCRIPTION "See Annex E of NTCIP 1103 v03 for a complete definition of this Type." SYNTAX INTEGER { valid (1), createRequest (2), underCreation (3), invalid (4) } dynObjData OBJECT-IDENTITY STATUS deprecated DESCRIPTION " A node containing SNMP object definitions of the dynamic objects. 1.3.6.1.4.1.1206.4.1.3.2" ::= { dynObjMgmt 2 } dynObjDefTableMaxEntries OBJECT-TYPE SYNTAX Integer32 (1..255) UNITS "entries" MAX-ACCESS read-only STATUS deprecated DESCRIPTION " This object specifies the maximum number of rows that may be implemented in the Dynamic Object Definition table. This object has been deprecated along with STMP. 1.3.6.1.4.1.1206.4.1.3.4" ::= { dynObjMgmt 4 } dynObjDef OBJECT-TYPE SYNTAX SEQUENCE OF DynObjEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION " A list of objects to be included in dynamic objects static ISO26048-1-DynObj.fdDynObjFieldTable This object has been deprecated along with STMP. 1.3.6.1.4.1.1206.4.1.3.1" ::= { dynObjMgmt 1 } dynObjEntry OBJECT-TYPE SYNTAX DynObjEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION " A list of OBJECT IDENTIFIERs that make up a dynamic object ISO26048-1-DynObj.fdDynObjFieldEntry This object has been deprecated along with STMP. 1.3.6.1.4.1.1206.4.1.3.1.1" INDEX { dynObjNumber, dynObjIndex } ::= { dynObjDef 1 } DynObjEntry ::= SEQUENCE { dynObjNumber Integer32, dynObjIndex Integer32, dynObjVariable OBJECT IDENTIFIER, dynObjOwner NtcipOwnerString, -- previously deprecated dynObjStatus EntryStatus } -- previously deprecated} dynObjNumber OBJECT-TYPE SYNTAX Integer32 ( 1..13) MAX-ACCESS read-only STATUS deprecated DESCRIPTION " The dynamic object number that this entry is to be associated with. ISO26048-1-DynObj.fdDynObjIndex This object has been deprecated along with STMP. 1.3.6.1.4.1.1206.4.1.3.1.1.1" ::= { dynObjEntry 1 } dynObjIndex OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS deprecated DESCRIPTION " An index that uniquely identifies an entry in the dynamic object table. Each entry defines an object that is to be associated with a dynamic object number. The dynObjIndex determines the order in which objects are transmitted for the associated dynamic object. The lower dynObjIndex numbers are transmitted before larger numbers for entries within the same dynamic object. ISO26048-1-DynObj.fdDynObjFieldIndex This object has been deprecated along with STMP. 1.3.6.1.4.1.1206.4.1.3.1.1.2" ::= { dynObjEntry 2 } dynObjVariable OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-write STATUS deprecated DESCRIPTION " The complete object identifier of the particular variable to be included in the specified dynamic object number. When defining dynamic objects, the maximum size of all the objects included in a dynamic object shall not exceed the maximum packet size of the communications network. When set to reference a columnar object, an agent may wish to only validate the prefix portion of the object identifier. The suffix or index portion of an object identifier need not be instantiated or exist at the time a dynObjVariable is defined. This object shall not reference any of the objects identified in NTCIP 1103 Clause 8.2. This object may not be modified unless the associated dynObjConfigStatus object is equal to underCreation. ISO26048-1-DynObj.fdDynObjFieldObject This object has been deprecated along with STMP. 1.3.6.1.4.1.1206.4.1.3.1.1.3" DEFVAL { zeroDotZero } ::= { dynObjEntry 3 } dynObjOwner OBJECT-TYPE SYNTAX NtcipOwnerString MAX-ACCESS read-write STATUS deprecated DESCRIPTION " This object has been replaced with dynObjConfigOwner. The entity that configured this entry and is therefore using the resources assigned to it. This object may not be modified if the associated dynObjStatus object is equal to valid(1). This object was deprecated in NTCIP 1103 v02. 1.3.6.1.4.1.1206.4.1.3.1.1.4" ::= { dynObjEntry 4 } dynObjStatus OBJECT-TYPE SYNTAX EntryStatus MAX-ACCESS read-write STATUS deprecated DESCRIPTION " This object has been replaced with dynObjConfigStatus. The status of this dynamic object definition entry. See description of EntryStatus above for restrictions on accesses. ISO26048-1-DynObj.fdDynObjFieldRowStatus This object was deprecated in NTCIP 1103 v02. 1.3.6.1.4.1.1206.4.1.3.1.1.5" ::= { dynObjEntry 5 } dynObj1 OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS deprecated DESCRIPTION " The value of this object is determined by the dynObjDef entries with dynObjNumber equal to 1. Packed Encoding Rules are utilized to encode the objects for transmission. This object is intended for use with the Simple Transportation Management Protocol, and provides little advantage if used with SNMP. If no objects are defined for this dynamic object number, then an error of noSuchName shall be returned by the agent. ISO26048-1-DynObj.fdDynObjCurrentValue and fdDynObjNewValue This object has been deprecated along with STMP. 1.3.6.1.4.1.1206.4.1.3.2.1" ::= { dynObjData 1 } dynObj2 OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS deprecated DESCRIPTION " The value of this object is determined by the dynObjDef entries with dynObjNumber equal to 2. Packed Encoding Rules are utilized to encode the objects for transmission. This object is intended for use with the Simple Transportation Management Protocol, and provides little advantage if used with SNMP. If no objects are defined for this dynamic object number, then an error of noSuchName shall be returned by the agent ISO26048-1-DynObj.fdDynObjCurrentValue and fdDynObjNewValue This object has been deprecated along with STMP. 1.3.6.1.4.1.1206.4.1.3.2.2" ::= { dynObjData 2 } dynObj3 OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS deprecated DESCRIPTION " The value of this object is determined by the dynObjDef entries with dynObjNumber equal to 3. Packed Encoding Rules are utilized to encode the objects for transmission. This object is intended for use with the Simple Transportation Management Protocol, and provides little advantage if used with SNMP. If no objects are defined for this dynamic object number, then an error of noSuchName shall be returned by the agent ISO26048-1-DynObj.fdDynObjCurrentValue and fdDynObjNewValue This object has been deprecated along with STMP. 1.3.6.1.4.1.1206.4.1.3.2.3" ::= { dynObjData 3 } dynObj4 OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS deprecated DESCRIPTION " The value of this object is determined by the dynObjDef entries with dynObjNumber equal to 4. Packed Encoding Rules are utilized to encode the objects for transmission. This object is intended for use with the Simple Transportation Management Protocol, and provides little advantage if used with SNMP. If no objects are defined for this dynamic object number, then an error of noSuchName shall be returned by the agent ISO26048-1-DynObj.fdDynObjCurrentValue and fdDynObjNewValue This object has been deprecated along with STMP. 1.3.6.1.4.1.1206.4.1.3.2.4" ::= { dynObjData 4 } dynObj5 OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS deprecated DESCRIPTION " The value of this object is determined by the dynObjDef entries with dynObjNumber equal to 5. Packed Encoding Rules are utilized to encode the objects for transmission. This object is intended for use with the Simple Transportation Management Protocol, and provides little advantage if used with SNMP. If no objects are defined for this dynamic object number, then an error of noSuchName shall be returned by the agent ISO26048-1-DynObj.fdDynObjCurrentValue and fdDynObjNewValue This object has been deprecated along with STMP. 1.3.6.1.4.1.1206.4.1.3.2.5" ::= { dynObjData 5 } dynObj6 OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS deprecated DESCRIPTION " The value of this object is determined by the dynObjDef entries with dynObjNumber equal to 6. Packed Encoding Rules are utilized to encode the objects for transmission. This object is intended for use with the Simple Transportation Management Protocol, and provides little advantage if used with SNMP. If no objects are defined for this dynamic object number, then an error of noSuchName shall be returned by the agent ISO26048-1-DynObj.fdDynObjCurrentValue and fdDynObjNewValue This object has been deprecated along with STMP. 1.3.6.1.4.1.1206.4.1.3.2.6" ::= { dynObjData 6 } dynObj7 OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS deprecated DESCRIPTION " The value of this object is determined by the dynObjDef entries with dynObjNumber equal to 7. Packed Encoding Rules are utilized to encode the objects for transmission. This object is intended for use with the Simple Transportation Management Protocol, and provides little advantage if used with SNMP. If no objects are defined for this dynamic object number, then an error of noSuchName shall be returned by the agent ISO26048-1-DynObj.fdDynObjCurrentValue and fdDynObjNewValue This object has been deprecated along with STMP. 1.3.6.1.4.1.1206.4.1.3.2.7" ::= { dynObjData 7 } dynObj8 OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS deprecated DESCRIPTION " The value of this object is determined by the dynObjDef entries with dynObjNumber equal to 8. Packed Encoding Rules are utilized to encode the objects for transmission. This object is intended for use with the Simple Transportation Management Protocol, and provides little advantage if used with SNMP. If no objects are defined for this dynamic object number, then an error of noSuchName shall be returned by the agent ISO26048-1-DynObj.fdDynObjCurrentValue and fdDynObjNewValue This object has been deprecated along with STMP. 1.3.6.1.4.1.1206.4.1.3.2.8" ::= { dynObjData 8 } dynObj9 OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS deprecated DESCRIPTION " The value of this object is determined by the dynObjDef entries with dynObjNumber equal to 9. Packed Encoding Rules are utilized to encode the objects for transmission. This object is intended for use with the Simple Transportation Management Protocol, and provides little advantage if used with SNMP. If no objects are defined for this dynamic object number, then an error of noSuchName shall be returned by the agent ISO26048-1-DynObj.fdDynObjCurrentValue and fdDynObjNewValue This object has been deprecated along with STMP. 1.3.6.1.4.1.1206.4.1.3.2.9" ::= { dynObjData 9 } dynObj10 OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS deprecated DESCRIPTION " The value of this object is determined by the dynObjDef entries with dynObjNumber equal to 10. Packed Encoding Rules are utilized to encode the objects for transmission. This object is intended for use with the Simple Transportation Management Protocol, and provides little advantage if used with SNMP. If no objects are defined for this dynamic object number, then an error of noSuchName shall be returned by the agent ISO26048-1-DynObj.fdDynObjCurrentValue and fdDynObjNewValue This object has been deprecated along with STMP. 1.3.6.1.4.1.1206.4.1.3.2.10" ::= { dynObjData 10 } dynObj11 OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS deprecated DESCRIPTION " The value of this object is determined by the dynObjDef entries with dynObjNumber equal to 11. Packed Encoding Rules are utilized to encode the objects for transmission. This object is intended for use with the Simple Transportation Management Protocol, and provides little advantage if used with SNMP. If no objects are defined for this dynamic object number, then an error of noSuchName shall be returned by the agent ISO26048-1-DynObj.fdDynObjCurrentValue and fdDynObjNewValue This object has been deprecated along with STMP. 1.3.6.1.4.1.1206.4.1.3.2.11" ::= { dynObjData 11 } dynObj12 OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS deprecated DESCRIPTION " The value of this object is determined by the dynObjDef entries with dynObjNumber equal to 12. Packed Encoding Rules are utilized to encode the objects for transmission. This object is intended for use with the Simple Transportation Management Protocol, and provides little advantage if used with SNMP. If no objects are defined for this dynamic object number, then an error of noSuchName shall be returned by the agent ISO26048-1-DynObj.fdDynObjCurrentValue and fdDynObjNewValue This object has been deprecated along with STMP. 1.3.6.1.4.1.1206.4.1.3.2.12" ::= { dynObjData 12 } dynObj13 OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS deprecated DESCRIPTION " The value of this object is determined by the dynObjDef entries with dynObjNumber equal to 13. Packed Encoding Rules are utilized to encode the objects for transmission. This object is intended for use with the Simple Transportation Management Protocol, and provides little advantage if used with SNMP. If no objects are defined for this dynamic object number, then an error of noSuchName shall be returned by the agent ISO26048-1-DynObj.fdDynObjCurrentValue and fdDynObjNewValue This object has been deprecated along with STMP. 1.3.6.1.4.1.1206.4.1.3.2.13" ::= { dynObjData 13 } dynObjConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF DynObjConfigEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION " A table consisting of an owner and status for each of the 13 dynamic object definitions.
static ISO26048-1-DynObj.fdDynObjTable This object has been deprecated along with STMP. 1.3.6.1.4.1.1206.4.1.3.3" ::= { dynObjMgmt 3 } dynObjConfigEntry OBJECT-TYPE SYNTAX DynObjConfigEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION " A table consisting of an owner and status for each of the 13 dynamic object definitions. ISO26048-1-DynObj.fdDynObjEntry This object has been deprecated along with STMP. 1.3.6.1.4.1.1206.4.1.3.3.1" INDEX { dynObjNumber } ::= { dynObjConfigTable 1 } DynObjConfigEntry ::= SEQUENCE { dynObjConfigOwner NtcipOwnerString, dynObjConfigStatus ConfigEntryStatus} dynObjConfigOwner OBJECT-TYPE SYNTAX NtcipOwnerString MAX-ACCESS read-write STATUS deprecated DESCRIPTION " The entity that configured the associated dynamic object. This object may not be modified unless the associated dynObjConfigStatus object is equal to underCreation. ISO26048-1-Owner.fdOwnerIndex This object has been deprecated along with STMP. 1.3.6.1.4.1.1206.4.1.3.3.1.1" DEFVAL { "" } ::= { dynObjConfigEntry 1 } dynObjConfigStatus OBJECT-TYPE SYNTAX ConfigEntryStatus MAX-ACCESS read-write STATUS deprecated DESCRIPTION " Indicates the state of the associated dynamic object. Depending on the validity checks that are performed on the dynamic object definition, a set request may or may not be honored. See Clause 5.2.4.1 for a complete description. ISO26048-1-DynObj.fdDynObjRowStatus This object has been deprecated along with STMP. 1.3.6.1.4.1.1206.4.1.3.3.1.2" ::= { dynObjConfigEntry 2 } END