-- OIDref derived MIB transcription. Original PDF: https://www.ntcip.org/file/2018/11/NTCIP1207v0214hj.pdf -- Publisher front matter and notices follow as comments. -- A Joint Standard of AASHTO, ITE, and NEMA -- -- -- -- NTCIP 1207 version v02 -- -- National Transportation -- Communications for ITS Protocol -- Object Definitions for -- Ramp Meter Control (RMC) Units -- -- Published September 2014 -- -- This Adobe® PDF copy of an NTCIP standard is available at no-cost for a limited time through -- support from the U.S. DOT ITS Joint Program Office, whose assistance is gratefully -- acknowledged. -- -- -- -- -- Published by -- -- American Association of State Highway and Transportation Officials (AASHTO) -- 444 North Capitol Street, N.W., Suite 249 -- Washington, D.C. 20001 -- -- Institute of Transportation Engineers (ITE) -- 1627 I (“Eye”) Street, N.W., Suite 600 -- Washington, D.C. 20006 -- -- National Electrical Manufacturers Association (NEMA) -- 1300 North 17th Street, Suite 900 -- Rosslyn, Virginia 22209-3801 -- -- -- -- file version 1207 v02.14j --  2014 AASHTO / ITE / NEMA. All rights reserved. -- . -- -- NOTICES -- -- Copyright Notice -- --  2014 by the American Association of State Highway and Transportation Officials (AASHTO), the -- Institute of Transportation Engineers (ITE), and the National Electrical Manufacturers Association -- (NEMA). All intellectual property rights, including, but not limited to, the rights of reproduction, translation -- and display are reserved under the laws of the United States of America, the Universal Copyright -- Convention, the Berne Convention, and the International and Pan American Copyright Conventions. -- Except as licensed or permitted, you may not copy these materials without prior written permission from -- AASHTO, ITE, or NEMA. Use of these materials does not give you any rights of ownership or claim of -- copyright in or to these materials. -- -- Visit www.ntcip.org for other copyright information, for instructions to request reprints of excerpts, and to -- request reproduction that is not granted below. -- -- -- PDF File License Agreement -- -- To the extent that these materials are distributed by AASHTO / ITE / NEMA in the form of an Adobe® -- Portable Document Format (PDF) electronic data file (the “PDF file”), AASHTO / ITE / NEMA authorizes -- each registered PDF file user to view, download, copy, or print the PDF file available from the authorized -- website, subject to the terms and conditions of this license agreement: -- -- a) you may download one copy of each PDF file for personal, noncommercial, and intraorganizational -- use only; -- b) ownership of the PDF file is not transferred to you; you are licensed to use the PDF file; -- c) you may make one more electronic copy of the PDF file, such as to a second hard drive or burn to a -- CD; -- d) you agree not to copy, distribute, or transfer the PDF file from that media to any other electronic -- media or device; -- e) you may print one paper copy of the PDF file; -- f) you may make one paper reproduction of the printed copy; -- g) any permitted copies of the PDF file must retain the copyright notice, and any other proprietary -- notices contained in the file; -- h) the PDF file license does not include (1) resale of the PDF file or copies, (2) republishing the content -- in compendiums or anthologies, (3) publishing excerpts in commercial publications or works for hire, -- (4) editing or modification of the PDF file except those portions as permitted, (5) posting on network -- servers or distribution by electronic mail or from electronic storage devices, and (6) translation to -- other languages or conversion to other electronic formats; -- i) other use of the PDF file and printed copy requires express, prior written consent. -- -- -- Data Dictionary and MIB Distribution Permission -- -- To the extent that these materials are distributed by AASHTO / ITE / NEMA in the form of a Data -- Dictionary (“DD”) or Management Information Base (“MIB”), AASHTO / ITE / NEMA extend the following -- permission: -- -- You may make or distribute unlimited copies, including derivative works, of the DD or MIB, including -- copies for commercial distribution, provided that: -- -- a) each copy you make or distribute includes the citation “Derived from NTCIP 0000 [insert the standard -- number]. Copyright by AASHTO / ITE / NEMA. Used by permission.”; -- -- b) the copies or derivative works are not made part of the standard publications or works offered by -- other standard developing organizations or publishers or as works-for-hire not associated with -- commercial hardware or software products intended for field implementation; -- c) use of the DD or MIB is restricted in that the syntax fields may only be modified to define: 1) a more -- restrictive subrange; or 2) a subset of the standard enumerated values; or 3) a set of retired and -- defined enumerated values for systems supporting multiversion interoperability; -- d) the description field may be modified but only to the extent that: 1) the more restrictive subrange is -- defined; and 2) only those bit values or enumerated values that are supported are listed. -- -- These materials are delivered “AS IS” without any warranties as to their use or performance. -- -- AASHTO / ITE / NEMA and their suppliers do not warrant the performance or results you may -- obtain by using these materials. AASHTO / ITE / NEMA and their suppliers make no warranties, -- express or implied, as to noninfringement of third party rights, merchantability, or fitness for any -- particular purpose. In no event will AASHTO / ITE / NEMA or their suppliers be liable to you or any -- third party for any claim or for any consequential, incidental or special damages, including any -- lost profits or lost savings, arising from your reproduction or use of these materials, even if an -- AASHTO / ITE / NEMA representative has been advised of the possibility of such damages. -- -- Some states or jurisdictions do not allow the exclusion or limitation of incidental, consequential, or special -- damages, or the exclusion of implied warranties, so the above limitations may not apply to a given user. -- -- Use of these materials does not constitute an endorsement or affiliation by or between AASHTO, ITE, or -- NEMA and the user, the user’s company, or the products and services of the user’s company. -- -- If the user is unwilling to accept the foregoing restrictions, he or she should immediately return these -- materials. -- -- -- PRL and RTM Distribution Permission -- -- To the extent that these materials are distributed by AASHTO / ITE / NEMA in the form of a Profile -- Requirements List (“PRL”) or a Requirements Traceability Matrix (“RTM”), AASHTO / ITE / NEMA extend -- the following permission: -- -- a) you may make or distribute unlimited copies, including derivative works of the PRL (then known as a -- Profile Implementation Conformance Statement (“PICS”)) or the RTM, provided that each copy you -- make or distribute contains the citation “Based on NTCIP 0000 [insert the standard number] PRL or -- RTM. Used by permission. Original text © AASHTO / ITE / NEMA.” -- b) you may only modify the PRL or the RTM by adding: 1) text in the Project Requirements column, -- which is the only column that may be modified to show a product’s implementation or the project- -- specific requirements; and/or 2) additional table columns or table rows that are clearly labeled as -- ADDITIONAL for project-unique or vendor-unique features; and -- c) if the PRL or RTM excerpt is made from an unapproved draft, add to the citation “PRL (or RTM) -- excerpted from a draft standard containing preliminary information that is subject to change.” -- -- This limited permission does not include reuse in works offered by other standards developing -- organizations or publishers, and does not include reuse in works-for-hire, compendiums, or electronic -- storage devices that are not associated with procurement documents, or commercial hardware, or -- commercial software products intended for field installation. -- -- A PICS is a Profile Requirements List that is completed to indicate the features that are supported in an -- implementation. Visit www.ntcip.org for information on electronic copies of the MIBs, PRLs, and RTMs. -- -- Content and Liability Disclaimer -- -- The information in this publication was considered technically sound by the consensus of persons -- engaged in the development and approval of the document at the time it was developed. Consensus does -- not necessarily mean that there is unanimous agreement among every person participating in the -- development of this document. -- -- AASHTO, ITE, and NEMA standards and guideline publications, of which the document contained herein -- is one, are developed through a voluntary consensus standards development process. This process -- brings together volunteers and seeks out the views of persons who have an interest in the topic covered -- by this publication. While AASHTO, ITE, and NEMA administer the process and establish rules to -- promote fairness in the development of consensus, they do not write the document and they do not -- independently test, evaluate, or verify the accuracy or completeness of any information or the soundness -- of any judgments contained in their standards and guideline publications. -- -- AASHTO, ITE, and NEMA disclaim liability for any personal injury, property, or other damages of any -- nature whatsoever, whether special, indirect, consequential, or compensatory, directly or indirectly -- resulting from the publication, use of, application, or reliance on this document. AASHTO, ITE, and NEMA -- disclaim and make no guaranty or warranty, express or implied, as to the accuracy or completeness of -- any information published herein, and disclaims and makes no warranty that the information in this -- document will fulfill any of your particular purposes or needs. AASHTO, ITE, and NEMA do not undertake -- to guarantee the performance of any individual manufacturer or seller’s products or services by virtue of -- this standard or guide. -- -- In publishing and making this document available, AASHTO, ITE, and NEMA are not undertaking to -- render professional or other services for or on behalf of any person or entity, nor are AASHTO, ITE, and -- NEMA undertaking to perform any duty owed by any person or entity to someone else. Anyone using this -- document should rely on his or her own independent judgment or, as appropriate, seek the advice of a -- competent professional in determining the exercise of reasonable care in any given circumstances. -- Information and other standards on the topic covered by this publication may be available from other -- sources, which the user may wish to consult for additional views or information not covered by this -- publication. -- -- AASHTO, ITE, and NEMA have no power, nor do they undertake to police or enforce compliance with the -- contents of this document. AASHTO, ITE, and NEMA do not certify, test, or inspect products, designs, or -- installations for safety or health purposes. Any certification or other statement of compliance with any -- health or safety-related information in this document shall not be attributable to AASHTO, ITE, or NEMA -- and is solely the responsibility of the certifier or maker of the statement. -- -- -- Trademark Notice -- -- NTCIP is a trademark of AASHTO / ITE / NEMA. All other marks mentioned in this standard are the -- trademarks of their respective owners. -- -- NTCIP 1207 v02.14 -- Page i -- -- -- ACKNOWLEDGEMENTS -- -- NTCIP 1207 v02 was prepared by the NTCIP Ramp Meter Control Working Group, which is a subdivision -- of the Joint Committee on the NTCIP. The Joint Committee is organized under a Memorandum of -- Understanding among AASHTO, ITE, and (NEMA). The Joint Committee on the NTCIP consists of six -- representatives from each of the standards organizations, and provides guidance for NTCIP -- development. -- -- At the time that NTCIP 1207 v02 was prepared, the following individuals were active members of the -- NTCIP RMC Working Group: -- -- • Brian Simi (Chair) • Joerg ‘Nu’ Rosenbohm -- • Sean Coughlin • Edmund Chang -- • Terry Haukom • Glenn Massarano -- • W.L. ‘Bud’ Kent • Jeff McRae -- • Mark Fox • Mark Morse -- -- Other individuals providing input to NTCIP 1207 v02 include: -- -- • Blake Christie • Pete Marshall -- • David Cordone • Tom Timcho -- • John Haigwood • Jeris White -- • Curtis Herrick -- • -- -- In addition to the many volunteer efforts, recognition is also given to those organizations which supported -- the efforts of the working group by providing comments and funding for NTCIP 1207 v02, including: -- -- • Batelle -- • California Department of Transportation (Caltrans) -- • Minnesota Department of Transportation (MnDOT) -- • Noblis Inc. (formerly known as Mitretek Inc.) -- • Siemens (formerly known as Eagle Traffic Control Systems and Gardner Systems) -- • Ministry of Transportation of Ontario (MTO) -- • Telvent Farradyne Inc. (formerly known as PB Farradyne) -- • Texas Transportation Institute (TTI) -- • TransCore Inc. -- • Washington State Department of Transportation (WSDOT) -- -- In addition to the many volunteer efforts, the U.S. Department of Transportation, Federal Highway -- Administration and Joint Program Office, provided funding assistance for the development of the NTCIP -- standards and associated documents. -- -- -- -- --  2014 AASHTO / ITE / NEMA Do Not Copy Without Written Permission -- -- NTCIP 1207 v02.14 -- Page ii -- -- FOREWORD -- -- NTCIP 1207 v02 identifies and defines how a management station may wish to interface with a field -- device to control and monitor RMC units. NTCIP 1207 v02 provides definitions of data elements for use -- within ramp meter control. The data is defined using the Simple Network Management Protocol (SNMP) -- object-type format as defined in RFC 1212. NTCIP 1207 v02 defines requirements that are applicable to -- all NTCIP RMC units and also contains optional and conditional sections that are applicable to specific -- environments for which they are intended. -- -- NTCIP 1207 v02 contains two normative and three informative annexes: -- -- a) Annex A is informative and contains the Operations Concept and basically the functional -- requirements of a RMC unit. -- b) Annex B is normative and contains the Profile Requirements List (PRL), which has also been referred -- to as a Profile Implementation Conformance Statement (PICS). The PRL table includes each of the -- defined object definitions, their potential value ranges, an indication whether the object is a control, -- status, or database parameter, and a column allowing a user to enter project-specific information. -- Since 2007 when NTCIP 1207 v02 last underwent major revision, the organization and formatting of -- the systems engineering content in 1200-series standards has evolved. The NTCIP 1207 v03 will -- present systems engineering content in the more complete and correct format. -- c) Annex C is informative and contains the object tree showing the major nodes of the RMC unit object -- structure within the Global object tree. -- d) Annex D does not currently contain any data. In future, this annex is intended to contain the test -- procedures for testing a device for conformance to NTCIP 1207 v02, which is designated as a -- Normative annex. -- e) Annex E is informative and contains all the changes that have been made between the prior version -- of NTCIP 1207 and NTCIP 1207 v02. -- -- NTCIP 1207 v02 is an NTCIP Data Dictionary Standard. Data Dictionary Standards provide definitions of -- data elements for use within NTCIP systems. -- -- NTCIP 1207 v02 uses only metric units. The following keywords apply: AASHTO, ITE, NEMA, NTCIP, -- rmc, ramp meter, ramp metering data dictionary, and object. -- -- For more information about NTCIP standards, visit the NTCIP website at www.ntcip.org. -- -- -- User Comment Instructions -- -- The term “User Comment” includes any type of written inquiry, comment, question, or proposed revision, -- from an individual person or organization, about any part of NTCIP 1207 v02 content. A “Request for -- Interpretation” of NTCIP 1207 v02 content is also classified as a User Comment. User Comments are -- solicited at any time. In preparation of this NTCIP standards publication, input of users and other -- interested parties was sought and evaluated. -- -- All User Comments are referred to the committee responsible for developing and/or maintaining NTCIP -- 1207 v02. The committee chairperson, or their designee, may contact the submitter for clarification of the -- User Comment. When the committee chairperson or designee reports the committee’s consensus opinion -- related to the User Comment, that opinion is forwarded to the submitter. The committee chairperson may -- report that action on the User Comment may be deferred to a future committee meeting and/or a future -- revision of the standards publication. Previous User Comments and their disposition may be available for -- reference and information at www.ntcip.org. -- -- A User Comment should be submitted to this address: -- -- -- -- -- Do Not Copy Without Written Permission  2014 AASHTO / ITE / NEMA -- -- NTCIP 1207 v02.14 -- Page iii -- -- NTCIP Coordinator -- National Electrical Manufacturers Association -- 1300 North 17th Street, Suite 900 -- Rosslyn, Virginia 22209-3801 -- e-mail: ntcip@nema.org -- -- A User Comment should be submitted in the following form: -- -- Standards Publication number and version: -- Page: -- Section and Paragraph (with Table or Figure, where appropriate): -- Comment: -- Editorial or Substantive?: -- Suggested Alternative Language: -- -- Please include your name, organization, and address in your correspondence. -- -- -- Approvals -- -- NTCIP 1207 v02 was separately balloted and approved by AASHTO, ITE, and NEMA after -- recommendation by the Joint Committee on the NTCIP. Each organization has NTCIP 1207 v02 as the -- following standard type, as of the date: -- -- AASHTO – Standard Specification; August 2014 -- ITE – Software Standard; September 2014 -- NEMA – Standard; September 2014 -- -- -- History -- -- In 1992, the NEMA 3-TS Transportation Management Systems and Associated Control Devices Section -- began the effort to develop the NTCIP. The Transportation Section’s purpose was to respond to user -- needs to include standardized systems communication in the NEMA TS 2 standard, Traffic Controller -- Assemblies. Under the guidance of the Federal Highway Administration’s NTCIP Steering Group, the -- NEMA effort was expanded to include the development of communications standards for all transportation -- field devices that could be used in an Intelligent Transportation Systems (ITS) network. -- -- In September 1996, an agreement was executed among AASHTO, ITE, and NEMA to jointly develop, -- approve, and maintain the NTCIP standards. The Joint Committee on the NTCIP formed a working group -- to develop a set of object definitions for RMC units. The Working Group’s first meeting was in February -- 1997. -- -- From 1996 to 1999, NTCIP 1207 was referenced as TS 3.RMC. However, to provide an organized -- numbering scheme for the NTCIP documents, the new referenc is NTCIP 1207. The technical -- specifications of NTCIP 1207 are identical to the former reference, except as noted in the development -- history below: -- -- TS 3.RMC version 98.01.10. October 1998 – Accepted as a User Comment Draft by the Joint -- Committee on the NTCIP. February 1999 - NTCIP Standards Bulletin B0029 distributed for user -- comment. -- -- NTCIP 1207 v01.16. November 1999 – Accepted v01.15 as a Recommended Standard by the -- Joint Committee on the NTCIP. October 2000 - NTCIP Standards Bulletin B0056 referred v01.16 -- for balloting. Approved by AASHTO in February 2001, approved by ITE in May 2001, and -- approved by NEMA in May 2001. -- -- -- --  2014 AASHTO / ITE / NEMA Do Not Copy Without Written Permission -- -- NTCIP 1207 v02.14 -- Page iv -- -- -- NTCIP 1207:2001 v01.17. November 2001: Prepared document for publication; updated -- document to NTCIP 8002 v04 Template format, added approvals and history to Foreword, and -- revised Foreword and Introduction. -- -- NTCIP 1207 v02.06b: This version is the User Comment Draft version of NTCIP 1207 version 2. -- This version was prepared to address interoperability issues found during external testing and -- implementations. Additionally, the concept of block objects as well as a Protocol Requirements -- List (PRL, formerly referenced as a Protocol Implementation Conformance Statement (PICS)) -- was added to the standard. -- -- NTCIP 1207 v02.11: This version is the Recommended Standard Draft version of NTCIP 1207 -- version 2. This version addresses the received user comments. Additionally, the Conformance -- Groups defining traps, which were contained in the UCD (1207 v02.06b), were taken out, -- because an NTCIP Joint Committee decision directed that the reference document, NTCIP 1103 -- v02, was remove the trap definition (until such time as consensus could be achieved). Therefore, -- NTCIP 1207 v02 only contains a placeholder. -- -- NTCIP 1207 v02.12: This version addresses the received ballot comments. -- -- NTCIP 1207 v02.13: This version of NTCIP 1207 v02 was submitted for Standards Developing -- Organization (SDO) ballot and approval. -- -- NTCIP 1207 v02.14: This version of NTCIP 1207 v02 was published. -- -- -- Compatibility of Versions -- -- To distinguish NTCIP 1207 v02 (as published) from previous drafts, NTCIP 1207 v02 also includes -- NTCIP 1207 v02.14 on each page header. All NTCIP Standards Publications have a major and minor -- version number for configuration management. The version number syntax is "v00.00a," with the major -- version number before the period, and the minor version number and edition letter (if any) after the -- period. -- -- NTCIP 1207 v02 is designated, and should be cited as, NTCIP 1207 v02. Anyone using NTCIP 1207 v02 -- should seek information about the version number that is of interest to them in any given circumstance. -- The MIB, the PRL, and the PICS should all reference the version number of the standards publication that -- was the source of the excerpted material. -- -- Conformant systems based on later, or higher, version numbers MAY NOT be compatible with -- conformant systems based on earlier, or lower, version numbers. Anyone using NTCIP 1207 v02 should -- also consult NTCIP 8004 v02 for specific guidelines on compatibility. -- -- -- -- -- Do Not Copy Without Written Permission  2014 AASHTO / ITE / NEMA N207v0214-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE --, TIMETICKS FROM RFC-1212 ramp -- Deleted devices to reference from TMIB-II -- and added references to ramp FROM NTCIP 8004 v02.17; rmcCfg OBJECT IDENTIFIER::= { ramp 1 } -- This node is an identifier used to group all objects for the configuration -- of general parameters that are common to all ramp meter control units. rmcCommRefreshThreshold OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION " This is an RMC parameter that is being used for each metered lane. If no successful SET command communication has been issued to the rmcCommActionMode-object of a metered lane for the time indicated in this threshold, the value of the rmcCommActionStatus-object for that metered lane shall be set to 'noComm'. This value shall be expressed in 1-second increments. A suggested usable range is 0, 20 to 14400. A value of zero (0) shall inhibit communications refresh timing. second 1.3.6.1.4.1.1206.4.2.2.1.1" REFERENCE "see Clause A.3" DEFVAL { 0 } ::={ rmcCfg 1 } rmcCalcInterval OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the duration of a single calculation interval consisting of data analysis, averaging and processing. This value shall be expressed in 1-second increments. A suggested usable range is 10 to 30. second 1.3.6.1.4.1.1206.4.2.2.1.2" REFERENCE "See Clause A.2.1, A.2.2, A.2.2.1, A.2.2.2, A.2.2.3, A.2.3.1, A.3, A.4.1, A.7.1, A.7.2, A.8.3.1.4.2, A.8.5.3.4.2, and A.9.1" DEFVAL { 30 } ::={ rmcCfg 2 } rmcML OBJECT IDENTIFIER ::={ ramp 2 } -- This node is an identifier used to group all objects for the configuration, -- control and status of the mainline lanes that are common to all ramp meter -- control units. rmcAveragingPeriods OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "This value indicates the number of calculation intervals over which the mainline station averages are be calculated. This value shall be expressed in 1-interval increments. A suggested usable range is 1 to 60. interval 1.3.6.1.4.1.1206.4.2.2.2.1" REFERENCE "See Clause A.4" DEFVAL { 2 } ::={ rmcML 1 } rmcMaxNumML OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the maximum number of mainline lanes that can be stored in the Mainline Lane Configuration and Control Table, and, by association, in all other mainline lane tables. number 1.3.6.1.4.1.1206.4.2.2.2.2" REFERENCE "See Clause A.2.1" ::={ rmcML 2 } -- USERS TAKE NOTE OF MULTIPLE VERSIONS - -- the INTEGER range was changed to start at 1 instead of 0. This -- does not cause backwards compatibility problems because this object would -- not have been supported, if the function was not supported in the device. rmcNumML OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the actual number of mainline lanes that are present in the Mainline Lane Configuration and Control Table, and, by association, in all other mainline lane tables. This value shall not exceed the value of the rmcMaxNumML-object. number 1.3.6.1.4.1.1206.4.2.2.2.3" REFERENCE "See Clause A.2.1" ::={ rmcML 3 } -- USERS TAKE NOTE OF MULTIPLE VERSIONS - -- the INTEGER range was changed to start at 1 instead of 0. This -- does not cause backwards compatibility problems because this object would -- not have been supported, if the function was not supported in the device. rmcMLCtrlTable OBJECT-TYPE SYNTAX SEQUENCE OF RmcMLCtrlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing the configuration and control information for the mainline lanes. static 1.3.6.1.4.1.1206.4.2.2.2.4" ::={ rmcML 4 } rmcMLCtrlEntry OBJECT-TYPE SYNTAX RmcMLCtrlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Configuration and control parameters of the mainline lane table. A particular row of this table can be managed using the rmcMLMode-object. 1.3.6.1.4.1.1206.4.2.2.2.4.1" INDEX { rmcMLNumber } ::={ rmcMLCtrlTable 1 } RmcMLCtrlEntry ::=SEQUENCE { rmcMLNumber INTEGER, rmcMLMode INTEGER, rmcMLLeadZoneLength INTEGER, -- deprecated rmcMLTrailZoneLength INTEGER, -- deprecated rmcMLUsageMode INTEGER, rmcMLSpeedTrapSpacing INTEGER, -- deprecated rmcMLErraticCount INTEGER, rmcMLMaxPresence INTEGER, rmcMLNoActivity INTEGER, rmcVehicleLength INTEGER, -- deprecated rmcMLLeadZoneLengthV2 INTEGER, rmcMLTrailZoneLengthV2 INTEGER, rmcMLSpeedTrapSpacingV2 INTEGER, rmcVehicleLengthV2 INTEGER } rmcMLNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "Enumerated listing of the mainline lanes. This value shall not exceed the value of the rmcMaxNumML-object. number 1.3.6.1.4.1.1206.4.2.2.2.4.1.1" REFERENCE "See Clause A.2.1" ::={ rmcMLCtrlEntry 1 } -- USERS TAKE NOTE OF MULTIPLE VERSIONS - -- the INTEGER range was changed to start at 1 instead of 0. This -- does not cause backwards compatibility problems because this object would -- not have been supported, if the function was not supported in the device. rmcMLMode OBJECT-TYPE SYNTAX INTEGER { disabled (1), singleEnabledLead (2), singleEnabledTrail (3), dualEnabled (4), preprocessedEnabled (5) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the mode of the mainline lane. The values are: disabled - indicates that no detector is enabled. When set to this value, the content of the entire row shall be invalidated; however, the row shall not be deleted. singleEnabledLead - indicates that only the leading detector shall be enabled. The trailing detector status shall be disabled. singleEnabledTrail - indicates that only the trailing detector shall be enabled. The leading detector status shall be disabled. dualEnabled - indicates that both the leading and trailing detectors shall be enabled. preprocessedEnabled - indicates that no detector shall be enabled but traffic data is provided by another process / device. 1.3.6.1.4.1.1206.4.2.2.2.4.1.2" REFERENCE "See Clause A.2.1" DEFVAL { 2 } ::={ rmcMLCtrlEntry 2 } rmcMLLeadZoneLength OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS deprecated DESCRIPTION "Indicates the detection zone length of the leading detector. This value shall be expressed in 0.1-meter increments (i.e, 40 = 4.0 meters). A suggested usable range is 0 to 50. tenth of meter 1.3.6.1.4.1.1206.4.2.2.2.4.1.3" REFERENCE "See Clause A.2.1" DEFVAL { 30 } ::={ rmcMLCtrlEntry 3 } -- USERS TAKE NOTE OF MULTIPLE VERSIONS - this object was deprecated in -- version 02 and replaced with an object of a similar name and function. -- The reason for the development of the new object and deprecation of this -- object is that deployment experiences have shown that the unit resolution -- was not fine enough for applications. This new object uses 0.01-meter -- increments instead of the 0.1-meter increments used in this object. rmcMLTrailZoneLength OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS deprecated DESCRIPTION "Indicates the detection zone length of the trailing detector. This value shall be expressed in 0.1-meter increments (i.e, 40 = 4.0 meters). A suggested usable range is 0 to 50. tenth of meter 1.3.6.1.4.1.1206.4.2.2.2.4.1.4" REFERENCE "See Clause A.2.1" DEFVAL { 30 } ::={ rmcMLCtrlEntry 4 } -- USERS TAKE NOTE OF MULTIPLE VERSIONS - this object was deprecated in -- version 02 and replaced with an object of a similar name and function. -- The reason for the development of the new object and deprecation of this -- object is that deployment experiences have shown that the unit resolution -- was not fine enough for applications. This new object uses 0.01-meter -- increments instead of the 0.1-meter increments used in this object. rmcMLUsageMode OBJECT-TYPE SYNTAX INTEGER { notUsed (1), schemeF (2), schemeO (3), schemeFO (4), schemeS (5), schemeFS (6), schemeOS (7), schemeFOS (8), determinedByOther (9) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates which mainline station traffic parameters will use the data from this lane. The values are: notUsed - the lane data will not be used to calculate any mainline station parameter. schemeF - the lane data will be used to calculate the rmcAverageFlowRate- object schemeO - the lane data will be used to calculate the rmcAverageOccupancy- object schemeFO - the lane data will be used to calculate the rmcAverageFlowRate- object and rmcAverageOccupancy-object schemeS - the lane data will be used to calculate the rmcAverageSpeed-object schemeFS - the lane data will be used to calculate the rmcAverageFlowRate- object and rmcAverageSpeed-object schemeOS - the lane data will be used to calculate the rmcAverageOccupancy- object and rmcAverageSpeed-object schemeFOS - the lane data will be used to calculate the rmcAverageFlowRate- object, rmcAverageOccupancy-object and rmcAverageSpeed-object determinedByOther - the rmcMLUsageStatus-object will determine the mainline lane data usage. 1.3.6.1.4.1.1206.4.2.2.2.4.1.5" REFERENCE "See Clause A.2.1" DEFVAL { 4 } ::={ rmcMLCtrlEntry 5 } rmcMLSpeedTrapSpacing OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS deprecated DESCRIPTION "Indicates the spacing between the leading and trailing detector measured from upstream edge to upstream edge of the detectors. This value shall be expressed in 0.1-meter increments (i.e, 40 = 4.0 meters). A suggested usable range is 20 to 150. A value of zero (0) shall inhibit the calculation of speed. tenth of meter 1.3.6.1.4.1.1206.4.2.2.2.4.1.6" REFERENCE "See Clause A.2.1" DEFVAL { 61 } ::={ rmcMLCtrlEntry 6 } -- USERS TAKE NOTE OF MULTIPLE VERSIONS - this object was deprecated in -- version 02 and replaced with an object of a similar name and function. -- The reason for the development of the new object and deprecation of this -- object is that deployment experiences have shown that the unit resolution -- was not fine enough for applications. This new object uses 0.01-meter -- increments instead of the 0.1-meter increments used in this object. rmcMLErraticCount OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "If the vehicle count, over the most recently completed calculation interval,on a mainline lane detector exceeds this threshold, the rmcMLLeadStatus- (or rmcMLTrailStatus-) object for that detector shall be set to a value of 'erraticCount'. This value shall be expressed in 1-vehicle increments. A suggested usable range is 0 to 30. A value of zero (0) shall inhibit the erratic count testing. number 1.3.6.1.4.1.1206.4.2.2.2.4.1.7" REFERENCE "See Clause A.2.1" DEFVAL { 30 } ::={ rmcMLCtrlEntry 7 } rmcMLMaxPresence OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "If the input of a mainline lane detector has been continuously actuated for longer than this threshold, the rmcMLLeadStatus- (or rmcMLTrailStatus-) object for that detector shall be set to a value of 'maxPresence'. This value shall be expressed in 1-minute increments. A suggested usable range is 0 to 1500. A value of zero (0) shall inhibit the maximum presence testing. minute 1.3.6.1.4.1.1206.4.2.2.2.4.1.8" REFERENCE "See Clause A.2.1" DEFVAL { 2 } ::={ rmcMLCtrlEntry 8 } rmcMLNoActivity OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "If the input of a mainline lane detector has not been actuated for longer than this threshold, the rmcMLLeadStatus- (or rmcMLTrailStatus-) object for that detector shall be set to a value of 'noActivity'. This value shall be expressed in 1-minute increments. A suggested usable range is 0 to 1500. A value of zero (0) shall inhibit the no activity testing. minute 1.3.6.1.4.1.1206.4.2.2.2.4.1.9" REFERENCE "See Clause A.2.1" DEFVAL { 0 } ::={ rmcMLCtrlEntry 9 } rmcVehicleLength OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS deprecated DESCRIPTION "Indicates the length of a typical vehicle in 0.1 m, which is used for mainline lane speed estimation with a single working detector per mainline lane. This value shall be expressed in 0.1-meter increments (i.e, 40 = 4.0 meters). A suggested usable range is 0 and 15 to 100. A value of zero (0) shall inhibit speed estimation. tenth of meter 1.3.6.1.4.1.1206.4.2.2.2.4.1.10" REFERENCE "See Clause A.2.1" DEFVAL { 0 } ::={ rmcMLCtrlEntry 10 } -- USERS TAKE NOTE OF MULTIPLE VERSIONS - this object was deprecated in -- version 02 and replaced with an object of a similar name and function. -- The reason for the development of the new object and deprecation of this -- object is that deployment experiences have shown that the unit resolution -- was not fine enough for applications. This new object uses 0.01-meter -- increments instead of the 0.1-meter increments used in this object. rmcMLLeadZoneLengthV2 OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the detection zone length of the leading detector. This value shall be expressed in 0.01-meter increments (i.e, 400 = 4.00 meters). A suggested usable range is 000 to 500. hundredth of meter 1.3.6.1.4.1.1206.4.2.2.2.4.1.11" REFERENCE "See Clause A.2.1" DEFVAL { 300 } ::={ rmcMLCtrlEntry 11 } -- USERS TAKE NOTE OF MULTIPLE VERSIONS - this object replaces the version 1 -- object of the same name and function. However, deployment experiences -- have shown that the unit is not fine enough for applications. This new -- object uses 0.01-meter increments instead of the 0.1-meter increments -- used in version 1. Because of this, the SYNTAX range also needed to -- change. rmcMLTrailZoneLengthV2 OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the detection zone length of the trailing detector. This value shall be expressed in 0.01-meter increments (i.e, 400 = 4.00 meters). A suggested usable range is 000 to 500. hundredth of meter 1.3.6.1.4.1.1206.4.2.2.2.4.1.12" REFERENCE "See Clause A.2.1" DEFVAL { 300 } ::={ rmcMLCtrlEntry 12 } -- USERS TAKE NOTE OF MULTIPLE VERSIONS - this object replaces the version 1 -- object of the same name and function. However, deployment experiences -- have shown that the unit is not fine enough for applications. This new -- object uses 0.01-meter increments instead of the 0.1-meter increments -- used in version 1. Because of this, the SYNTAX range also needed to -- change. rmcMLSpeedTrapSpacingV2 OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the spacing between the leading and trailing detector measured from upstream edge to upstream edge of the detectors. This value shall be expressed in 0.01-meter increments (i.e, 400 = 4.00 meters). A suggested usable range is 200 to 1500. A value of zero (0) shall inhibit the calculation of speed. hundredth of meter 1.3.6.1.4.1.1206.4.2.2.2.4.1.13" REFERENCE "See Clause A.2.1" DEFVAL { 61 } ::={ rmcMLCtrlEntry 13 } -- USERS TAKE NOTE OF MULTIPLE VERSIONS - this object replaces the version 1 -- object of the same name and function. However, deployment experiences -- have shown that the unit is not fine enough for applications. This new -- object uses 0.01-meter increments instead of the 0.1-meter increments -- used in version 1. Because of this, the SYNTAX range also needed to -- change. rmcVehicleLengthV2 OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the length of a typical vehicle in 0.01 m, which is used for mainline lane speed estimation with a single working detector per mainline lane. This value shall be expressed in 0.1-meter increments (i.e, 400 = 4.00 meters). A suggested usable range is 0 and 150 to 1000. A value of zero (0) shall inhibit speed estimation. hundredth of meter 1.3.6.1.4.1.1206.4.2.2.2.4.1.14" REFERENCE "See Clause A.2.1" DEFVAL { 0 } ::={ rmcMLCtrlEntry 14 } -- USERS TAKE NOTE OF MULTIPLE VERSIONS - this object replaces the version 1 -- object of the same name and function. However, deployment experiences -- have shown that the unit is not fine enough for applications. This new -- object uses 0.01-meter increments instead of the 0.1-meter increments -- used in version 1. Because of this, the SYNTAX range also needed to -- change. rmcMaxNumFlowNoActivityTableEntries OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the maximum number of entries in the Mainline Flow-based No Activity Table. A suggested minimum value is two (2). number 1.3.6.1.4.1.1206.4.2.2.2.9" REFERENCE "See Clause A.4.2" ::={ rmcML 9 } rmcNumFlowNoActivityTableEntries OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the actual number of entries in the Mainline Flow-based No Activity Table. This value shall not exceed the value of the rmcMaxNumFlowNoActivityTableEntries-object. number 1.3.6.1.4.1.1206.4.2.2.2.10" REFERENCE "See Clause A.4.2" ::={ rmcML 10 } rmcMLFlowBasedNoActivityTable OBJECT-TYPE SYNTAX SEQUENCE OF RmcMLFlowBasedNoActivityEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing the configuration information for an entry in the Mainline Flow-based No Activity Table. The purpose of this table is to define the duration for the flow-based no activity diagnostic test. The duration will vary with the Average Station Flow Rate. Flow-based No Activity Threshold value in the first entry shall be the maximum threshold. If the value of the rmcAverageFlowRate-object is less than the value of the rmcFlowRateNoActivityThreshold-object in this entry row and greater than the value in the following entry, then the Flow-based No Activity Duration in that entry shall be used. If the value of the rmcAverageFlowRate-object is less than the value of the rmcFlowRateNoActivityThreshold-object in the last entry, then the Flow-based No Activity Duration of the last entry shall be used. If the value of the rmcAverageFlowRate-object is greater than the maximum value of the rmcFlowRateNoActivityThreshold-object in the table, then the Mainline Flow-based No Activity test shall be disabled. The first instance of the rmcFlowRateNoActivityThreshold-object whose value is zero indicates the end of the valid table contents. Rows prior to the end of the valid rows that contain a value of zero (0) for the rmcFlowBasedNoActivityDuration-object indicate that this row shall NOT be used for flow-based no activity testing. Additionally, the following rules shall be used when configuring this table: - All rmcFlowRateNoActivityThreshold-object entries in the table shall be decreasing for increasing indices. - All rmcFlowBasedNoActivityDuration-object entries in the table shall be non-decreasing for increasing indices. - if the value of the rmcNumFlowRateLanes-object is ‘0’, then the rmcFlowRateNoActivityDuration-object shall have a value of ‘0’.
static. 1.3.6.1.4.1.1206.4.2.2.2.11" ::={ rmcML 11 } rmcMLFlowBasedNoActivityEntry OBJECT-TYPE SYNTAX RmcMLFlowBasedNoActivityEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Configuration parameters for a row of the table. A particular entry/row of this table can be managed using the rmcFlowBasedNoActivityDuration-object. When this object is set to zero, then the associated row shall be ignored for the determination of the duration value for the flow-based no activity diagnostic test. 1.3.6.1.4.1.1206.4.2.2.2.11.1" INDEX { rmcMLFlowBasedNoActivityIndex } ::={ rmcMLFlowBasedNoActivityTable 1 } RmcMLFlowBasedNoActivityEntry ::=SEQUENCE { rmcMLFlowBasedNoActivityIndex INTEGER, rmcFlowBasedNoActivityThreshold INTEGER, rmcFlowBasedNoActivityInterval INTEGER } rmcMLFlowBasedNoActivityIndex OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "Key into this table defining an enumerated listing of row entries that indicate the number of flow-based no activity threshold / duration pairs stored for this RMC unit. This value shall not exceed the value of the rmcMaxNumFlowNoActivityTableEntries-object. number 1.3.6.1.4.1.1206.4.2.2.2.11.1.1" REFERENCE "See Clause A.4.2" ::={ rmcMLFlowBasedNoActivityEntry 1 } rmcFlowBasedNoActivityThreshold OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the flow-based no activity threshold which will be used to determine the no activity duration value. This value shall be expressed in 1-vph increments. A suggested usable range is 0, 200-3600. The first instance of a value of zero (0) indicates that this is the last valid entry of the table. Additional rows of the table, regardless of the value, shall be ignored. vehicles per hour 1.3.6.1.4.1.1206.4.2.2.2.11.1.2" REFERENCE "See Clause A.4.2" ::={ rmcMLFlowBasedNoActivityEntry 2 } rmcFlowBasedNoActivityInterval OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the duration of the flow-based no activity interval, which is associated with the flow-based no activity threshold defined in the same row. This value shall be expressed in 1-minute increments. A suggested usable range is 0, 1-240 minutes. minute 1.3.6.1.4.1.1206.4.2.2.2.11.1.3" REFERENCE "See Clause A.4.2" ::={ rmcMLFlowBasedNoActivityEntry 3 } rmcAverageFlowRate OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the flow rate measured over the rmcAveragingPeriods-object number of preceding calculation intervals. The flow rate shall be determined by calculating the average of all mainline lanes whose rmcMLStatus-object value is NOT ‘total failure’ or ‘disabled’ at any time during the previous averaging periods number of calculation intervals, AND whose rmcMLUsageStatus- object has a value of 'schemeF', 'schemeFO', 'schemeFS', or 'schemeFOS'. Any mainline lane whose rmcMLStatus-object had a value of 'totalFailure' during the Averaging Periods shall not be used for the calculation. The value of this object shall be calculated using a lane average. The value shall be expressed in vph in 1-vph increments. vehicles per hour 1.3.6.1.4.1.1206.4.2.2.2.5" REFERENCE "See Clause A.4" ::={ rmcML 5 } rmcAverageOccupancy OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the occupancy measured over the rmcAveragingPeriods-object number of preceding calculation intervals. The occupancy shall be determined by calculating the average of all mainline lanes whose rmcMLStatus-object value is NOT ‘total failure’ or ‘disabled’ at any time during the previous averaging periods number of calculation intervals, AND whose rmcMLUsageStatus- object has a value of 'schemeO', 'schemeFO', 'schemeOS', or 'schemeFOS'. Any mainline lane whose rmcMLStatus-object had a value of 'totalFailure' during the Averaging Periods shall not be used for the calculation. The value of this object shall be calculated using a lane average. The value shall be expressed in 0.1-percent increments (i.e, 40 = 4.0 percent). tenth of percent 1.3.6.1.4.1.1206.4.2.2.2.6" REFERENCE "See Clause A.4" ::={ rmcML 6 } rmcAverageSpeed OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the speed measured over the rmcAveragingPeriods-object number of preceding calculation intervals. The speed shall be determined by calculating the average of all mainline lanes using (A or B) and C: A) those mainline lanes whose rmcMLStatus-object value is NOT ‘total failure’ or ‘disabled’ at any time during the previous averaging periods number of calculation intervals, OR B) those mainline lanes whose rmcMLStatus-object value is ‘partial failure’ and whose rmcVehicleLength is NOT ‘0’, AND C) whose rmcMLUsageStatus-object as a value of 'schemeS', 'schemeFS', 'schemeOS', or 'schemeFOS'. Any mainline lane whose rmcMLStatus-object had: - a value of 'totalFailure' during the Averaging Periods, OR - a value of ‘partialFailure’ during the Averaging Periods and whose rmcMLMode-object has a value of ‘singleEnabledLead’ or ‘singleEnabledTrail’ (only one detector is used and speed estimation is disabled), shall not be used for the calculation. The value of this object shall be calculated using a vehicle average. The value shall be expressed in 1-km/h increments. kilometers per hour 1.3.6.1.4.1.1206.4.2.2.2.7" REFERENCE "See Clause A.4" ::={ rmcML 7 } rmcNumFlowRateLanes OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the number of mainline lanes used to calculate the rmcAverageFlowRate-object during the last calculation interval. This value shall not exceed the value of the rmcNumML-object. number 1.3.6.1.4.1.1206.4.2.2.2.12" REFERENCE "See Clause A.4" ::={ rmcML 12 } rmcNumAverageOccupancyLanes OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the number of mainline lanes used to calculate the rmcAverageOccupancy-object during the last calculation interval. This value shall not exceed the value of the rmcNumML-object. number 1.3.6.1.4.1.1206.4.2.2.2.13" REFERENCE "See Clause A.4" ::={ rmcML 13 } rmcNumAverageSpeedLanes OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the number of mainline lanes used to calculate the rmcAverageSpeed- object during the last calculation interval. This value shall not exceed the value of the rmcNumML-object. number 1.3.6.1.4.1.1206.4.2.2.2.14" REFERENCE "See Clause A.4" ::={ rmcML 14 } rmcMLStatTable OBJECT-TYPE SYNTAX SEQUENCE OF RmcMLStatEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing the status information for a mainline lane.
static 1.3.6.1.4.1.1206.4.2.2.2.8" ::={ rmcML 8 } rmcMLStatEntry OBJECT-TYPE SYNTAX RmcMLStatEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Status parameters of the mainline lane status table. This table is directly correlated to the Mainline Lane Configuration and Control Table, which means that the number of rows in this table is exactly the same as the number of rows in the Mainline Lane Configuration and Control Table (AUGMENT TABLE in SNMPv2terminology). Table management can only take place through the Mainline Lane Configuration and Control Table, while this table provides only status information about the mainline lanes. 1.3.6.1.4.1.1206.4.2.2.2.8.1" INDEX { rmcMLNumber } ::={ rmcMLStatTable 1 } RmcMLStatEntry ::=SEQUENCE { rmcMLLeadStatus INTEGER, rmcMLTrailStatus INTEGER, rmcMLStatus INTEGER, rmcMLUsageStatus INTEGER, rmcMLHistLeadStatus INTEGER, -- added in version 2 rmcMLHistTrailStatus INTEGER -- added in version 2 } rmcMLLeadStatus OBJECT-TYPE SYNTAX INTEGER { disabled (1), working (2), otherError (3), erraticCount (4), maxPresence (5), noActivity (6), errorAtSensor (7), flowBasedNoActivity (8) -- added in version 2 } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the status of the leading detector. The values are: disabled - indicates that this detector is not used. working - indicates that this detector has no error. otherError - indicates an error not defined here. See Operator's Manual. erraticCount - indicates that the vehicle count for this detector has exceeded the value of its rmcMLErraticCount-object. maxPresence - indicates a continuous actuation for this detector that has exceeded the value of its rmcMLMaxPresence-object. noActivity - indicates a continuous non-actuation for this detector that has exceeded the value of its rmcMLNoActivity-object. errorAtSensor - indicates that the sensor for this detector has reported an error. See Operator's manual flowBasedNoActivity - indicates a continuous non-actuation for this detector that has exceeded the value of its rmcMLFlowBasedNoActivity-object. 1.3.6.1.4.1.1206.4.2.2.2.8.1.1" REFERENCE "See Clause A.2.1" ::={ rmcMLStatEntry 1 } rmcMLTrailStatus OBJECT-TYPE SYNTAX INTEGER { disabled (1), working (2), otherError (3), erraticCount (4), maxPresence (5), noActivity (6), errorAtSensor (7), flowBasedNoActivity (8) –- added in version 2 } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the status of the trailing detector. The values are: disabled - indicates that this detector is not used. working - indicates that this detector has no error. otherError - indicates an error not defined here. See Operator's manual. erraticCount - indicates that the vehicle count for this detector has exceeded the value of its rmcMLErraticCount-object. maxPresence - indicates a continuous actuation for this detector that has exceeded the value of its rmcMLMaxPresence-object. noActivity - indicates a continuous non-actuation for this detector that has exceeded the value of its rmcMLNoActivity-object. errorAtSensor - indicates that the sensor for this detector has reported an error. See Operator's manual. flowBasedNoActivity - indicates a continuous non-actuation for this detector that has exceeded the value of its rmcMLFlowBasedNoActivity-object. 1.3.6.1.4.1.1206.4.2.2.2.8.1.2" REFERENCE "See Clause A.2.1" ::={ rmcMLStatEntry 2 } rmcMLStatus OBJECT-TYPE SYNTAX INTEGER { working (1), disabled (2), partialFailure (3), totalFailure (4) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the status of the mainline lane. The values are: working - indicates that the rmcMLMode-object has a value of either: a.) 'dualEnabled', and both the rmcMLLeadStatus-object and the rmcMLTrailStatus-object have the value of 'working', or b.) 'singleEnabledLead', and the rmcMLLeadStatus-object has the value of 'working', or c.) 'singleEnabledTrail', and the rmcMLTrailStatus-object has the value of 'working', or d.) 'preprocessedEnabled', and the device providing the traffic data has reported no error. disabled - indicates that the rmcMLMode-object has a value of either: a.) 'disabled', or b.) 'singleEnabledLead', and the rmcMLLeadStatus-object has the value of 'disabled', or c.) 'singleEnabledTrail', and the rmcMLTrailStatus-object has the value of 'disabled'. partialFailure - indicates that the rmcMLMode-object has a value of 'dualEnabled', but the value of one of rmcMLLeadStatus-object and rmcMLTrailStatus-object is NOT 'working', while the value of the other is 'working'. totalFailure - indicates that the rmcMLMode-object has a value of either: a.) 'dualEnabled', but the rmcMLLeadStatus-object and the rmcMLTrailStatus-object both have the value of NOT 'working', or b.) 'singleEnabledLead', and the rmcMLLeadStatus-object has the value of 'error', or c.) 'singleEnabledTrail', and the rmcMLTrailStatus-object has the value of 'error', or d.) 'preprocessedEnabled', and the device providing the traffic data has reported an error. 1.3.6.1.4.1.1206.4.2.2.2.8.1.3" REFERENCE "See Clause A.2.1" ::={ rmcMLStatEntry 3 } rmcMLUsageStatus OBJECT-TYPE SYNTAX INTEGER { notUsed (1), schemeF (2), schemeO (3), schemeFO (4), schemeS (5), schemeFS (6), schemeOS (7), schemeFOS (8) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates which mainline station traffic parameters use the data from this lane. If the value of the rmcMLUsageMode-object is NOT 'determinedByOthers', then the value is determined directly by that mode object. If, however, the value is 'determinedByOthers', then the value is determined by the TimeBaseControl mechanism. The values are: notUsed - the mainline lane traffic parameters are not used for averaging calculation. schemeF - the lane data will be used to calculate the rmcAverageFlowRate- object. schemeO - the lane data will be used to calculate the rmcAverageOccupancy- object. schemeFO - the lane data will be used to calculate the rmcAverageFlowRate- object and rmcAverageOccupancy-object. schemeS - the lane data will be used to calculate the rmcAverageSpeed-object. schemeFS - the lane data will be used to calculate the rmcAverageFlowRate- object and rmcAverageSpeed-object. schemeOS - the lane data will be used to calculate the rmcAverageOccupancy- object and rmcAverageSpeed-object. schemeFOS - the lane data will be used to calculate the rmcAverageFlowRate- object, rmcAverageOccupancy-object and rmcAverageSpeed-object. 1.3.6.1.4.1.1206.4.2.2.2.8.1.4" REFERENCE "See Clause A.2.1 and A.4" ::={ rmcMLStatEntry 4 } rmcMLHistLeadStatus OBJECT-TYPE SYNTAX INTEGER (0..65535) –- BITMAP16 ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the cumulative status of the leading detector. The values are: Bit Number Name Description Bit 15: reserved. Bit 14: reserved. Bit 13: reserved. Bit 12: reserved. Bit 11: reserved. Bit 10: reserved. Bit 09: reserved. Bit 08: reserved. Bit 07: Flow-based No Activity – the rmcMLLeadStatus-object has or had a value of ‘flowBasedNoActivity’ since reset. Bit 06: Error at Sensor – the rmcMLLeadStatus-object has or had a value of ‘ErrorAtSensor’ since reset. Bit 05: No activity – the rmcMLLeadStatus-object has or had a value of ‘noActivity’ since reset. Bit 04: Max presence – the rmcMLLeadStatus-object has or had a value of ‘maxPresence’ since reset. Bit 03: Erratic count – the rmcMLLeadStatus-object has or had a value of ‘erraticCount’ since reset. Bit 02: Other error – the rmcMLLeadStatus-object has or had a value of ‘otherError’ since reset. Bit 01: Working – the rmcMLLeadStatus-object has or had a value of ‘Working’ since reset. Bit 00: Disabled – the rmcMLLeadStatus-object has or had a value of ‘Disabled’ since reset. In the context of this object, ‘reset’ means either an initialization of the RMC or a successful SET of the rmcHistDetectorReset-object. When a ‘reset’ occurs, all bits shall be set to 0. If a bit is set to 0, the condition indicated by the bit is false; if it is set to 1, the condition is true. All reserved bits shall always be set to 'zero' (0). A bad value error shall be returned, if a management application writes a one (1) to any of the reserved bits. 1.3.6.1.4.1.1206.4.2.2.2.8.1.5" REFERENCE "See Clause A.2.1" ::={ rmcMLStatEntry 5 } rmcMLHistTrailStatus OBJECT-TYPE SYNTAX INTEGER (0..65535) –- BITMAP16 ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the cumulative status of the trailing detector. The status are: Bit Number Name Description Bit 15: reserved. Bit 14: reserved. Bit 13: reserved. Bit 12: reserved. Bit 11: reserved. Bit 10: reserved. Bit 09: reserved. Bit 08: reserved. Bit 07: Flow-based No Activity – the rmcMLTrailStatus-object has or had a value of ‘flowBasedNoActivity’ since reset. Bit 06: Error at Sensor – the rmcMLTrailStatus-object has or had a value of ‘Disabled’ since reset. Bit 05: No activity – the rmcMLTrailStatus-object has or had a value of ‘noActivity’ since reset. Bit 04: Max presence – the rmcMLTrailStatus-object has or had a value of ‘maxPresence’ since reset. Bit 03: Erratic count – the rmcMLTrailStatus-object has or had a value of ‘erraticCount’ since reset. Bit 02: Other error – the rmcMLTrailStatus-object has or had a value of ‘otherError’ since reset. Bit 01: Working – the rmcMLTrailStatus-object has or had a value of ‘Working’ since reset. Bit 00: Disabled – the rmcMLTrailStatus-object has or had a value of ‘Disabled’ since reset. In the context of this object, ‘reset’ means either an initialization of the RMC or a successful SET of the rmcHistDetectorReset-object. When a ‘reset’ occurs, all bits shall be set to 0. If a bit is set to 0, the condition indicated by the bit is not true; if it is set to 1, the condition is true. All reserved bits shall always be set to zero (0)'. A bad value error shall be returned, if a management application writes a one (1) to any of the reserved bits. 1.3.6.1.4.1.1206.4.2.2.2.8.1.6" REFERENCE "See Clause A.2.1" ::={ rmcMLStatEntry 6 } rmcFlowBasedNoActivityDuration OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the duration of time over which no activity shall be detected on a mainline lane detector prior to its status being set to 'flowBasedNoActivity'. This value is copied from the rmcFlowBasedNoActivityInterval object into this object, when that value becomes active/operational. minute 1.3.6.1.4.1.1206.4.2.2.2.15" REFERENCE "See Clause A.4.2" ::={ rmcML 15 } rmcMeter OBJECT IDENTIFIER ::={ ramp 3 } -- This node is an identifier used to group all objects for the configuration, -- control and status of the metered lanes that are common to all ramp -- meter control units. rmcMeterMain OBJECT IDENTIFIER ::={ rmcMeter 1 } -- This node is an identifier used to group the main objects for the -- configuration, control and status of the metered lanes that are -- common to all ramp meter control units. rmcMaxNumMeteredLanes OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the maximum number of metered lanes that can be stored in the Metered Lane Configuration Table, and, by association, in all other metered lane tables. number 1.3.6.1.4.1.1206.4.2.2.3.1.1" REFERENCE "See Clause A.2.2" ::={ rmcMeterMain 1 } -- USERS TAKE NOTE OF MULTIPLE VERSIONS - -- the INTEGER range was changed to start at 1 instead of 0. This -- does not cause backwards compatibility problems because this object would -- not have been supported, if the function was not supported in the device. rmcNumMeteredLanes OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the actual number of metered lanes that are present in the Metered Lane Configuration Table, and, by association, in all other metered lane tables. This value shall not exceed the value of the rmcMaxNumMeteredLanes– object. number 1.3.6.1.4.1.1206.4.2.2.3.1.2" REFERENCE "See Clause A.2.2" ::={ rmcMeterMain 2 } -- USERS TAKE NOTE OF MULTIPLE VERSIONS - -- the INTEGER range was changed to start at 1 instead of 0. This -- does not cause backwards compatibility problems because this object would -- not have been supported, if the function was not supported in the device. rmcMeterCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF RmcMeterCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing the configuration information for a metered lane.
static 1.3.6.1.4.1.1206.4.2.2.3.1.3" ::={ rmcMeterMain 3 } rmcMeterCfgEntry OBJECT-TYPE SYNTAX RmcMeterCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Configuration parameters of the metered lane table. This table is directly correlated to the Metered Lane Control Table, which means that the number of rows in this table is exactly the same as the number of rows in the Metered Lane Control Table (AUGMENT TABLE in SNMPv2 terminology). Table management can only take place through the Metered Lane Control Table, while this table provides configuration parameters for the associated metered lane. static 1.3.6.1.4.1.1206.4.2.2.3.1.3.1" INDEX { rmcMeterNumber } ::={ rmcMeterCfgTable 1 } RmcMeterCfgEntry ::=SEQUENCE { rmcMeterNumber INTEGER, rmcDependGroupNumber INTEGER, rmcDependGroupSeqNumber INTEGER, rmcCmdSourcePriorityOrder INTEGER, rmcDemandErraticCount INTEGER, rmcDemandMaxPresence INTEGER, rmcDemandNoActivity INTEGER, rmcMinMeterTime INTEGER, rmcMinNonMeterTime INTEGER, rmcAbsoluteMinMeterRate INTEGER, rmcAbsoluteMaxMeterRate INTEGER, rmcSystemMinMeterRate INTEGER, rmcSystemMaxMeterRate INTEGER, rmcStartAlert INTEGER, rmcStartWarning INTEGER, rmcStartGreen INTEGER, rmcStartGapTime INTEGER, rmcStartGapQueueDetectorNum INTEGER, rmcStartYellow INTEGER, rmcStartRed INTEGER, rmcMinRed INTEGER, rmcRedViolationClearance INTEGER, rmcRedViolationAdjust INTEGER, rmcMinGreen INTEGER, rmcMaxGreen INTEGER, rmcYellow INTEGER, rmcShortStopTime INTEGER, rmcShortStopOccupancy INTEGER, rmcShortStopQueueDetectorNum INTEGER, rmcLongStopTime INTEGER, rmcDemandGap INTEGER, rmcDemandRed INTEGER, rmcShutNormalRate INTEGER, rmcShutWarning INTEGER, rmcShutTime INTEGER, rmcPostMeterGreen INTEGER, rmcQueueViolationFlag INTEGER, rmcQueueShutdownFlag INTEGER, rmcQueueAdjustUsage INTEGER, rmcDemandDependMaxPresence INTEGER, -- added in version 2 rmcDemandDependNoActivity INTEGER -- added in version 2 } rmcMeterNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "Enumerated listing of the metered lanes. This value shall not exceed the value stated in the rmcMaxNumMeteredLanes- object. number 1.3.6.1.4.1.1206.4.2.2.3.1.3.1.1" REFERENCE "See Clause A.2.2, A.8.3.1.3 and A.8.5.3.3" ::={ rmcMeterCfgEntry 1 } rmcDependGroupNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the dependency group with which this metered lane is associated. This value shall not exceed the value of the rmcMaxNumDependGroup-object. number 1.3.6.1.4.1.1206.4.2.2.3.1.3.1.2" REFERENCE "See Clause A.2.2" ::={ rmcMeterCfgEntry 2 } rmcDependGroupSeqNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the unique position of this metered lane within its dependency group which determines the Ramp Lane Sequence. number 1.3.6.1.4.1.1206.4.2.2.3.1.3.1.3" REFERENCE "See Clause A.2.3.2" ::={ rmcMeterCfgEntry 3 } rmcCmdSourcePriorityOrder OBJECT-TYPE SYNTAX INTEGER { schemeCIT (1), schemeICT (2), schemeTCI (3), schemeTIC (4), schemeCTI (5), schemeITC (6) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the active command source priority order for this metered lane. The values are: schemeCIT -in decreasing order: manual, communications, interconnect, timebase control, default; schemeICT -in decreasing order: manual, interconnect, communications, timebase control, default; schemeTCI -in decreasing order: manual, timebase control, communications, interconnect, default; schemeTIC -in decreasing order: manual, timebase control, interconnect, communications, default; schemeCTI -in decreasing order: manual, communications, timebase control, interconnect, default; schemeITC -in decreasing order: manual, interconnect, timebase control, communications, default. 1.3.6.1.4.1.1206.4.2.2.3.1.3.1.4" REFERENCE "See Clause A.3" ::={ rmcMeterCfgEntry 4 } rmcDemandErraticCount OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "If the vehicle count, over the most recently completed calculation interval,on the demand detector for a metered lane exceeds this threshold, the rmcDemandStatus-object for that metered lane shall be set to a value of 'erraticCount'. This value shall be expressed in 1-vehicle increments. A suggested usable range is 0 to 30. A value of zero (0) shall inhibit the erratic count testing. number 1.3.6.1.4.1.1206.4.2.2.3.1.3.1.5" REFERENCE "See Clause A.2.2.1" ::={ rmcMeterCfgEntry 5 } rmcDemandMaxPresence OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "If the input on the demand detector for a metered lane has been continuously actuated for longer than the time indicated by this threshold, the rmcDemandStatus-object for that metered lane shall be set to a value of 'maxPresence'. This value shall be expressed in 1-minute increments. A suggested usable range is 0 to 1500. A value of zero (0) shall inhibit the maximum presence testing. minute 1.3.6.1.4.1.1206.4.2.2.3.1.3.1.6" REFERENCE "See Clause A.2.2.1" ::={ rmcMeterCfgEntry 6 } rmcDemandNoActivity OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "If the input on the demand detector for a metered lane has not been actuated for longer than the time indicated by this threshold, the rmcDemandStatus-object for that metered lane shall be set to a value of 'noActivity'. This value shall be expressed in 1-minute increments. A suggested usable range is 0 to 1500. A value of zero (0) shall inhibit the no activity testing. minute 1.3.6.1.4.1.1206.4.2.2.3.1.3.1.7" REFERENCE "See Clause A.2.2.1" ::={ rmcMeterCfgEntry 7 } rmcMinMeterTime OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the minimum length of the metering state. This will prevent excessive cycling of the ramp meter between the metering and non-metering states. This value shall be expressed in 1-minute increments. A suggested usable range is 0 to 60. minute 1.3.6.1.4.1.1206.4.2.2.3.1.3.1.8" REFERENCE "See Clause A.6" ::={ rmcMeterCfgEntry 8 } rmcMinNonMeterTime OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the minimum length of the non-metering state. This will prevent excessive cycling of the ramp meter between the metering and non-metering states. This value shall be expressed in 1-minute increments. A suggested usable range is 0 to 60. minute 1.3.6.1.4.1.1206.4.2.2.3.1.3.1.9" REFERENCE "See Clause A.5" ::={ rmcMeterCfgEntry 9 } rmcAbsoluteMinMeterRate OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the absolute minimum metering rate. This value shall be expressed in 1-vph increments. A suggested usable range is 0, 120 to 1800. A value of zero (0) indicates this parameter shall not be used. vehicles per hour 1.3.6.1.4.1.1206.4.2.2.3.1.3.1.10" REFERENCE "See Clause A.2.2" ::={ rmcMeterCfgEntry 10 } rmcAbsoluteMaxMeterRate OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the absolute maximum metering rate. This value shall be expressed in 1-vph increments. A suggested usable range is 0, 120 to 1800. A value of zero (0) indicates this parameter shall not be used. The value, if non-zero, shall be greater than or equal to the value of the rmcAbsoluteMinMeterRate-object. vehicles per hour 1.3.6.1.4.1.1206.4.2.2.3.1.3.1.11" REFERENCE "See Clause A.2.2" ::={ rmcMeterCfgEntry 11 } rmcSystemMinMeterRate OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the system minimum metering rate. This value shall be expressed in 1-vph increments. A suggested usable range is 0, 120 to 1800. A value of zero (0) indicates this parameter shall not be used. vehicles per hour 1.3.6.1.4.1.1206.4.2.2.3.1.3.1.12" REFERENCE "See Clause A.2.2" ::={ rmcMeterCfgEntry 12 } rmcSystemMaxMeterRate OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the system maximum metering rate. This value shall be expressed in 1-vph increments. A suggested usable range is 0, 120 to 1800. A value of zero (0) indicates this parameter shall not be used. The value, if non-zero, shall be greater than or equal to the value of the rmcSystemMinMeterRate-object. vehicles per hour 1.3.6.1.4.1.1206.4.2.2.3.1.3.1.13" REFERENCE "See Clause A.2.2" ::={ rmcMeterCfgEntry 13 } rmcStartAlert OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the length of the startup alert interval. This value shall be expressed in 0.1-second increments (i.e, 40 = 4.0 seconds). A suggested usable range is 0 to 600. A value of zero (0) shall cause the metered lane to bypass this interval. tenth of second 1.3.6.1.4.1.1206.4.2.2.3.1.3.1.14" REFERENCE "See Clause A.8.2.1" ::={ rmcMeterCfgEntry 14 } rmcStartWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the length of the startup warning interval. This value shall be expressed in 0.1-second increments (i.e, 40 = 4.0 seconds). A suggested usable range is 0 to 600. A value of zero (0) shall cause the metered lane to bypass this interval. tenth of second 1.3.6.1.4.1.1206.4.2.2.3.1.3.1.15" REFERENCE "See Clause A.8.2.2" ::={ rmcMeterCfgEntry 15 } rmcStartGreen OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the length of the startup green interval. This value shall be expressed in 0.1-second increments (i.e, 40 = 4.0 seconds). A suggested usable range is 0 to 600. A value of zero (0) shall cause the metered lane to bypass this interval. tenth of second 1.3.6.1.4.1.1206.4.2.2.3.1.3.1.16" REFERENCE "See Clause A.8.2.3" ::={ rmcMeterCfgEntry 16 } rmcStartGapTime OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the length of time between successive actuations of the detector identified by the rmcStartGapQueueDetectorNum-object necessary to terminate the startup green interval. This value shall be expressed in 0.1-second increments (i.e, 40 = 4.0 seconds). A suggested usable range is 0 and 10 to 150. A value of zero (0) shall make the termination of the interval dependent only on value of the rmcStartGreen-object. tenth of second 1.3.6.1.4.1.1206.4.2.2.3.1.3.1.17" REFERENCE "See Clause A.8.2.3" ::={ rmcMeterCfgEntry 17 } rmcStartGapQueueDetectorNum OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the queue detector that is used for startup gap calculations. The value of this object cannot be larger than the value of the rmcNumQueueEntries-object. number 1.3.6.1.4.1.1206.4.2.2.3.1.3.1.18" REFERENCE "See Clause A.8.2.3" ::={ rmcMeterCfgEntry 18 } rmcStartYellow OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the length of the startup yellow interval. This value shall be expressed in 0.1-second increments (i.e, 40 = 4.0 seconds). A suggested usable range is 0 and 20 to 100. A value of zero (0) shall cause the metered lane to bypass this interval. tenth of second 1.3.6.1.4.1.1206.4.2.2.3.1.3.1.19" REFERENCE "See Clause A.8.2.4" ::={ rmcMeterCfgEntry 19 } rmcStartRed OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the length of the startup red interval. This value shall be expressed in 0.1-second increments (i.e, 40 = 4.0 seconds). A suggested usable range is 20 to 100. A value of zero (0) shall cause the metered lane to bypass this interval. tenth of second 1.3.6.1.4.1.1206.4.2.2.3.1.3.1.20" REFERENCE "See Clause A.8.2.5" ::={ rmcMeterCfgEntry 20 } rmcMinRed OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the minimum length of the red interval. This value shall be expressed in 0.1-second increments (i.e, 40 = 4.0 seconds). A suggested usable range is 10 to 150. tenth of second 1.3.6.1.4.1.1206.4.2.2.3.1.3.1.21" REFERENCE "See Clause A.8.3.1.1 and A.8.5.3.1" ::={ rmcMeterCfgEntry 21 } rmcRedViolationClearance OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the length of time that has to elapse during the red interval before a red light violation can be detected. This value shall be expressed in 0.1-second increments (i.e, 40 = 4.0 seconds). A suggested usable range is 0 to 50. A value of zero (0) indicates that no red light violations shall be detected. tenth of second 1.3.6.1.4.1.1206.4.2.2.3.1.3.1.22" REFERENCE "See Clause A.8.3.1.2 and A.8.5.3.2" ::={ rmcMeterCfgEntry 22 } rmcRedViolationAdjust OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the length of time by which the current cycle will be extended for each red light violation. This value shall be expressed in 0.1-second increments (i.e, 40 = 4.0 seconds). A suggested usable range is 10 to 50. tenth of second 1.3.6.1.4.1.1206.4.2.2.3.1.3.1.23" REFERENCE "See Clause A.8.3.1.2 and A.8.5.3.2" ::={ rmcMeterCfgEntry 23 } rmcMinGreen OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the minimum length of the green interval. This value shall be expressed in 0.1-second increments (i.e, 40 = 4.0 seconds). A suggested usable range is 10 to 50. tenth of second 1.3.6.1.4.1.1206.4.2.2.3.1.3.1.24" REFERENCE "See Clause A.8.3.2.2 and A.8.5.1.2" ::={ rmcMeterCfgEntry 24 } rmcMaxGreen OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the maximum length of the green interval. This value shall be expressed in 0.1-second increments (i.e, 40 = 4.0 seconds). A suggested usable range is 10 to 150. tenth of second 1.3.6.1.4.1.1206.4.2.2.3.1.3.1.25" REFERENCE "See Clause A.8.3.2.3" ::={ rmcMeterCfgEntry 25 } rmcYellow OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the length of the yellow interval. This value shall be expressed in 0.1-second increments (i.e, 40 = 4.0 seconds). A suggested usable range is 0 and 5 to 50. A value of zero (0) shall cause the metered lane to bypass this interval. tenth of second 1.3.6.1.4.1.1206.4.2.2.3.1.3.1.26" REFERENCE "See Clause A.8.3.2.1, A.3.3, A.8.5.1.1 and A.8.5.2" ::={ rmcMeterCfgEntry 26 } rmcShortStopTime OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the length of time that has to elapse after the red interval has expired before a short stop condition can be detected. This value shall be expressed in 0.1-second increments (i.e, 40 = 4.0 seconds). A suggested usable range is 0 and 10 to 1200. A value of zero (0) shall inhibit short stop termination of the Red Interval. tenth of second 1.3.6.1.4.1.1206.4.2.2.3.1.3.1.27" REFERENCE "See Clause A.8.3.1.4.2 and A.8.5.3.4.2" ::={ rmcMeterCfgEntry 27 } rmcShortStopOccupancy OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the occupancy threshold at the detector identified by the rmcShortStopQueueDetectorNum-object, meaning that this detector is used to detect short stop conditions. This value shall be expressed in 0.1-percent increments (i.e, 40 = 4.0 percent). A suggested usable range is 0 to 1000. tenth of percent 1.3.6.1.4.1.1206.4.2.2.3.1.3.1.28" REFERENCE "See Clause A.8.3.1.4.2 and A.8.5.3.4.2" ::={ rmcMeterCfgEntry 28 } rmcShortStopQueueDetectorNum OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the queue detector that is used for short stop calculations. The value of this object cannot be larger than the value of the rmcNumQueueEntries-object. number 1.3.6.1.4.1.1206.4.2.2.3.1.3.1.29" REFERENCE "See Clause A.8.3.1.4.2" ::={ rmcMeterCfgEntry 29 } rmcLongStopTime OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the length of time that has to elapse after the red interval has expired before a long stop condition can be detected. This value shall be expressed in 0.1-second increments (i.e, 40 = 4.0 seconds). A suggested usable range is 0 and 10 to 100. A value of zero (0) shall inhibit long stop termination of the Red interval. tenth of second 1.3.6.1.4.1.1206.4.2.2.3.1.3.1.30" REFERENCE "See Clause A.8.3.1.4.3 and A.8.5.3.4.3" ::={ rmcMeterCfgEntry 30 } rmcDemandGap OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the length of time that has to elapse after the green interval has expired without actuation of the demand detector before a demand gap condition can be detected. This value shall be expressed in 0.1-second increments (i.e, 40 = 4.0 seconds). A suggested usable range is 10 to 50. tenth of second 1.3.6.1.4.1.1206.4.2.2.3.1.3.1.31" REFERENCE "See Clause A.8.3.1.4.4 and A.8.5.3.4.4" ::={ rmcMeterCfgEntry 31 } rmcDemandRed OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the length of time by which the current red interval will be extended once the demand detector is actuated after the detection of a demand gap condition. This value shall be expressed in 0.1-second increments (i.e, 40 = 4.0 seconds). A suggested usable range is 0 and 10 to 150. A value of zero (0) shall inhibit demand red extension of the current cycle. tenth of second 1.3.6.1.4.1.1206.4.2.2.3.1.3.1.32" REFERENCE "See Clause A.8.3.1.4.4 and A.8.5.3.4.4" ::={ rmcMeterCfgEntry 32 } rmcShutNormalRate OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the metering rate during shutdown when the rmcImplementAction- object has a value of either 'dark' or 'restInGreen'. This value shall be expressed in 1-vph increments. A suggested usable range is 120 to 1800. vehicles per hour 1.3.6.1.4.1.1206.4.2.2.3.1.3.1.33" REFERENCE "See Clause A.6.1" ::={ rmcMeterCfgEntry 33 } rmcShutWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the length of the shutdown warning interval. This value shall be expressed in 0.1-second increments (i.e, 40 = 4.0 seconds). A suggested usable range is 0 to 600. A value of zero (0) shall cause the metered lane to bypass this interval. tenth of second 1.3.6.1.4.1.1206.4.2.2.3.1.3.1.34" REFERENCE "See Clause A.8.5.4" ::={ rmcMeterCfgEntry 34 } -- USERS TAKE NOTE OF MULTIPLE VERSIONS - -- the INTEGER range was changed to end at 65535 instead of 255. -- This does not cause backwards compatibility problems because the value -- range of this object was expanded, which is allowed according to SNMP -- rules. rmcShutTime OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the minimum length of shutdown metering. This value shall be expressed in 1-second increments. A suggested usable range is 0 to 600. second 1.3.6.1.4.1.1206.4.2.2.3.1.3.1.35" REFERENCE "See Clause A.8.5.3.5" ::={ rmcMeterCfgEntry 35 } rmcPostMeterGreen OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the length of the Post-metering Green interval. This value shall be expressed in 0.1-second increments (i.e, 40 = 4.0 seconds). A suggested usable range is 0 to 600. A value of zero (0) shall cause the metered lane to bypass this interval. tenth of second 1.3.6.1.4.1.1206.4.2.2.3.1.3.1.36" REFERENCE "See Clause A.8.6.1" ::={ rmcMeterCfgEntry 36 } rmcQueueViolationFlag OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates whether queue adjustment will supersede red violations. 0=false - indicates that both queue and red violation adjustments may be performed simultaneously. 1=true - indicates that queue adjustment will supersede red violation adjustment. 1.3.6.1.4.1.1206.4.2.2.3.1.3.1.37" REFERENCE "See Clause A.8.3.1.2" DEFVAL { 0 } ::={ rmcMeterCfgEntry 37 } rmcQueueShutdownFlag OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates whether queue override takes precedence over shutdown metering. 0= false - allows the transition to the non-metering state regardless of queue override adjustments. 1= true - requires the queue override adjustments be completed before the transition to the non-metering state can begin. 1.3.6.1.4.1.1206.4.2.2.3.1.3.1.38" REFERENCE "See Clause A.6" ::={ rmcMeterCfgEntry 38 } rmcQueueAdjustUsage OBJECT-TYPE SYNTAX INTEGER { additive (1), additiveXI (2), priorityXI (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates which queue adjustments are made. additive= indicates that a queue adjustment shall be made for each queue detector (both excessive and intermediate queue detectors) whose rmcQueueFlag-object has a value of 'true'. additiveXI = indicates that a queue adjustment shall be made for each queue detector whose rmcQueueType-object has a value of 'excessive' and whose rmcQueueFlag-object has a value of 'true'. If no such detectors exist, a queue adjustment shall be made for each queue detector whose rmcQueueType- object has a value of 'intermediate' and whose rmcQueueFlag-object has a value of 'true'. priorityXI = indicates that a queue adjustment shall be made for the highest entry (lowest index value) queue detector whose rmcQueueType-object has a value of 'excessive' and whose rmcQueueFlag-object has a value of 'true'. If no detector exists that fulfills these requirements, a queue adjustment shall be made for the highest entry (lowest index value) queue detector whose rmcQueueType-object has a value of 'intermediate' and whose rmcQueueFlag-object has a value of 'true'. 1.3.6.1.4.1.1206.4.2.2.3.1.3.1.39" REFERENCE "See Clause A.9.2" ::={ rmcMeterCfgEntry 39 } rmcDemandDependMaxPresence OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "If the input on the demand detector for a metered lane has been continuously actuated, while the input on the passage detector for the same metered lane has been continuously non-actuated for longer than this threshold and the rmcPassageMode-object is not ‘recalled’ and the rmcPassageStatus-object is ‘working’ and the rmcMergeFlag-object is ‘false’, the rmcDemandStatus-object for this metered lane shall be set to a value of 'depMaxPresence'. This value shall be expressed in 1-second increments. A suggested usable range is 0 to 600. A value of zero (0) shall inhibit the dependent maximum presence testing. second 1.3.6.1.4.1.1206.4.2.2.3.1.3.1.40" REFERENCE "See Clause A.2.2.1" ::={ rmcMeterCfgEntry 40 } rmcDemandDependNoActivity OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "If the input on the demand detector for a metered lane has not been actuated, while more vehicles than indicated by this threshold have been counted on the passage detector of the same metered lane and the rmcPassageMode-object is not ‘recalled’ and the rmcPassageStatus-object is ‘working’, the rmcDemandStatus-object for this metered lane shall be set to a value of 'depNoActivity'. This value shall be expressed in 1-vehicle increments. A suggested usable range is 0 to 30. A value of zero (0) shall inhibit the dependent no activity testing. number 1.3.6.1.4.1.1206.4.2.2.3.1.3.1.41" REFERENCE "See Clause A.2.2.1" ::={ rmcMeterCfgEntry 41 } rmcMeterCtrlTable OBJECT-TYPE SYNTAX SEQUENCE OF RmcMeterCtrlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing the control information for a metered lane.
static 1.3.6.1.4.1.1206.4.2.2.3.1.7" ::={ rmcMeterMain 7 } --Editor’s Note: There is a skip in OID at this point, but this was already -- present in version 1 and I cannot change the OID in version 2 for any -- existing object. rmcMeterCtrlEntry OBJECT-TYPE SYNTAX RmcMeterCtrlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Control Parameters of the metered lane table. A particular row of this table can be managed using the rmcMeterMode-object. 1.3.6.1.4.1.1206.4.2.2.3.1.7.1" INDEX { rmcMeterNumber } ::={ rmcMeterCtrlTable 1 } RmcMeterCtrlEntry ::=SEQUENCE { rmcMeterMode INTEGER, rmcManualAction INTEGER, rmcManualPlan INTEGER, rmcManualRate INTEGER, rmcManualVehiclesPerGrn INTEGER, rmcIntercoAction INTEGER, rmcIntercoPlan INTEGER, rmcIntercoRate INTEGER, rmcIntercoVehiclesPerGrn INTEGER, rmcCommActionMode INTEGER, -- modified name only in version 2 rmcCommPlan INTEGER, rmcCommRate INTEGER, rmcCommVehiclesPerGrn INTEGER, rmcDefaultAction INTEGER, rmcDefaultPlan INTEGER, rmcDefaultRate INTEGER, rmcDefaultVehiclesPerGrn INTEGER, rmcDemandMode INTEGER, rmcPreMeterNonGreen INTEGER, –- added in version 2 rmcCritFlowRateThresh INTEGER, –- added in version 2 rmcCritOccupancyThresh INTEGER, –- added in version 2 rmcCriticalSpeedThreshold INTEGER –- added in version 2 } rmcMeterMode OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the mode of the metered lane. The values are: 0 = disabled - the metered lane is not used. 1 = enabled - the metered lane is used. 1.3.6.1.4.1.1206.4.2.2.3.1.7.1" REFERENCE "See Clause A.2.2" ::={ rmcMeterCtrlEntry 1 } rmcManualAction OBJECT-TYPE SYNTAX INTEGER { dark (1), restInGreen (2), fixedRate (3), trafficResponsive (4), emergencyGreen (5), skip (6) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the requested action while the value of the rmcImplementCommandSource-object is 'manual'. The values are: dark - indicates that the metered lane will advance to the Pre-Metering Non- Green interval. restInGreen - indicates that the metered lane will advance to the Pre- Metering Green interval. fixedRate - indicates that the metered lane will operate using the value of the rmcManualRate-object. trafficResponsive -indicates that the metered lane will operate using mainline station traffic conditions and the value of the rmcManualPlan-object. emergencyGreen - indicates that the metered lane will advance to and remain in the Post-metering Green interval without entering the Shutdown Green, Shutdown Yellow, Shutdown Red or Shutdown Warning intervals when the metered lane is NOT in the Non-metering state. The metered lane will advance to the Pre-Metering Green interval when the metered lane is in the Non-metering state. skip - indicates that the next-lower level command source shall be considered as specified by the rmcCmdSourcePriorityOrder-object. 1.3.6.1.4.1.1206.4.2.2.3.1.7.1.2" REFERENCE "See Clause A.3" ::={ rmcMeterCtrlEntry 2 } rmcManualPlan OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the requested metering plan number while the value of the rmcImplementCommandSource-object is 'manual' and the rmcRequestAction-object has a value of 'trafficResponsive'. This value shall not exceed the value of the rmcMaxNumMeterPlans-object. number 1.3.6.1.4.1.1206.4.2.2.3.1.7.1.3" REFERENCE "See Clause A.3" ::={ rmcMeterCtrlEntry 3 } rmcManualRate OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the requested metering rate while the value of the rmcImplementCommandSource-object is 'manual' and the rmcRequestAction-object has a value of 'fixedRate'. This value shall be expressed in 1-vph increments. A suggested usable range is 120-1800. vehicles per hour 1.3.6.1.4.1.1206.4.2.2.3.1.7.1.4" REFERENCE "See Clause A.3" ::={ rmcMeterCtrlEntry 4 } rmcManualVehiclesPerGrn OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the requested number of vehicles to pass during the green and yellow intervals of one cycle while the value of the rmcImplementCommandSource-object is 'manual'. The values shall be expressed in 1-vehicle increments. The suggested usable range is 1 to 5 vehicles. number 1.3.6.1.4.1.1206.4.2.2.3.1.7.1.5" REFERENCE "See Clause A.3" ::={ rmcMeterCtrlEntry 5 } rmcIntercoAction OBJECT-TYPE SYNTAX INTEGER { dark (1), restInGreen (2), fixedRate (3), trafficResponsive (4), emergencyGreen (5), skip (6) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the requested action if the metered lane is commanded by interconnect. The values are: dark - indicates that the metered lane will advance to the Pre-Metering Non- Green interval. restInGreen - indicates that the metered lane will advance to the Pre- Metering Green interval. fixedRate - indicates that the metered lane will operate using the value of the rmcIntercoRate-object. trafficResponsive -indicates that the metered lane will operate using mainline station traffic conditions and the value of the rmcIntercoPlan-object. emergencyGreen - indicates that the metered lane will advance to and remain in the Post-metering Green interval without entering the Shutdown Green, Shutdown Yellow, Shutdown Red or Shutdown Warning intervals when the metered lane is NOT in the Non-metering state. The metered lane will advance to the Pre-Metering Green interval when the metered lane is in the Non-metering state. skip - indicates that the next-lower level command source shall be considered as specified by the rmcCmdSourcePriorityOrder-object. 1.3.6.1.4.1.1206.4.2.2.3.1.7.1.6" REFERENCE "See Clause A.3" ::={ rmcMeterCtrlEntry 6 } rmcIntercoPlan OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the requested metering plan number if the metered lane is commanded by interconnect and the rmcRequestAction-object has a value of 'trafficResponsive'. This value shall not exceed the value of the rmcMaxNumMeterPlans-object. number 1.3.6.1.4.1.1206.4.2.2.3.1.7.1.7" REFERENCE "See Clause A.3" ::={ rmcMeterCtrlEntry 7 } rmcIntercoRate OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the requested metering rate if the metered lane is commanded by interconnect and the rmcRequestAction-object has a value of 'fixedRate'. This value shall be expressed in 1-vph increments. A suggested usable range is 120 to 1800. vehicles per hour 1.3.6.1.4.1.1206.4.2.2.3.1.7.1.8" REFERENCE "See Clause A.3" ::={ rmcMeterCtrlEntry 8 } rmcIntercoVehiclesPerGrn OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the requested number of vehicles to pass during the green and yellow intervals of one cycle while the metered lane is commanded by interconnect (value of the rmcImplementCommandSource- object is 'interconnect'). This value shall be expressed in 1-vehicle increments. A suggested usable range is 1 to 5. number 1.3.6.1.4.1.1206.4.2.2.3.1.7.1.9" REFERENCE "See Clause A.3" ::={ rmcMeterCtrlEntry 9 } rmcCommActionMode OBJECT-TYPE SYNTAX INTEGER { dark (1), restInGreen (2), fixedRate (3), trafficResponsive (4), emergencyGreen (5), skip (6) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the commanded action from the TMC. When this object is set, the value of this object is copied into the rmcCommActionStatus object. The values are: dark - indicates that the metered lane will advance to the Pre-Metering Non- Green interval. restInGreen - indicates that the metered lane will advance to the Pre-Metering Green interval. fixedRate - indicates that the metered lane will operate using the value of the rmcCommRate-object. trafficResponsive -indicates that the metered lane will operate using mainline station traffic conditions and the value of the rmcCommPlan-object. emergencyGreen - indicates that the metered lane will advance to and remain in the Post-metering Green interval without entering the Shutdown Green, Shutdown Yellow, Shutdown Red or Shutdown Warning intervals when the metered lane is NOT in the Non-metering state. The metered lane will advance to the Pre-Metering Green interval when the metered lane is in the Non-metering state. skip - indicates that the next-lower level command source shall be considered as specified by the rmcCmdSourcePriorityOrder-object. 1.3.6.1.4.1.1206.4.2.2.3.1.7.1.10" REFERENCE "See Clause A.3" ::={ rmcMeterCtrlEntry 10 } -- USERS TAKE NOTE OF MULTIPLE VERSIONS - -- the name of the object was changed from ‘rmcCommActionStatus’ to -- ‘rmcCommActionMode’. This change does not cause any backwards -- compatibility problems. rmcCommPlan OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the requested metering plan number if the metered lane is commanded by communications and the rmcRequestAction-object has a value of 'trafficResponsive'. This value shall not exceed the value of the rmcMaxNumMeteringPlans-object. number 1.3.6.1.4.1.1206.4.2.2.3.1.7.1.11" REFERENCE "See Clause A.3" ::={ rmcMeterCtrlEntry 11 } rmcCommRate OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the requested metering rate in vehicles per hour (vph) if the metered lane is commanded by communications and the rmcRequestAction-object has a value of 'fixedRate'. This value shall be expressed in 1-vph increments. A suggested usable range is 120 to 1800. vehicles per hour 1.3.6.1.4.1.1206.4.2.2.3.1.7.1.12" REFERENCE "See Clause A.3" ::={ rmcMeterCtrlEntry 12 } rmcCommVehiclesPerGrn OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the requested number of vehicles that are allowed to pass during the green and yellow intervals of one cycle while the metered lane is commanded by communications (value of the rmcImplementCommandSource-object is 'communications'). This value shall be expressed in 1-vehicle increments. A suggested usable range is 1 to 5. number 1.3.6.1.4.1.1206.4.2.2.3.1.7.1.13" REFERENCE "See Clause A.3" ::={ rmcMeterCtrlEntry 13 } rmcDefaultAction OBJECT-TYPE SYNTAX INTEGER { dark (1), restInGreen (2), fixedRate (3), trafficResponsive (4), emergencyGreen (5) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the requested action if the metered lane is commanded by default settings. The values are: dark - indicates that the metered lane will advance to the Pre-Metering Non- Green interval. restInGreen - indicates that the metered lane will advance to the Pre-Metering Green interval. fixedRate - indicates that the metered lane will operate using the value of the rmcDefaultRate-object. trafficResponsive -indicates that the metered lane will operate using mainline station traffic conditions and the value of the rmcDefaultPlan-object. emergencyGreen - indicates that the metered lane will advance to and remain in the Post-metering Green interval without entering the Shutdown Green, Shutdown Yellow, Shutdown Red or Shutdown Warning intervals when the metered lane is NOT in the Non-metering state. The metered lane will advance to the Pre-Metering Green interval when the metered lane is in the Non-metering state. 1.3.6.1.4.1.1206.4.2.2.3.1.7.1.14" REFERENCE "See Clause A.3" ::={ rmcMeterCtrlEntry 14 } rmcDefaultPlan OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the requested metering plan number if the metered lane is commanded by default settings and the rmcRequestAction-object has a value of 'trafficResponsive'. This value shall not exceed the value of the rmcMaxNumMeteringPlans-object. number 1.3.6.1.4.1.1206.4.2.2.3.1.7.1.15" REFERENCE "See Clause A.3" ::={ rmcMeterCtrlEntry 15 } rmcDefaultRate OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the requested metering rate if the metered lane is commanded by default settings and the rmcRequestAction-object has a value of 'fixedRate'. This value shall be expressed in 1-vph increments. A suggested usable range is 120 to 1800. vehicles per hour 1.3.6.1.4.1.1206.4.2.2.3.1.7.1.16" REFERENCE "See Clause A.3" ::={ rmcMeterCtrlEntry 16 } rmcDefaultVehiclesPerGrn OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the number of vehicles that are allowed to pass during the green and yellow intervals of one cycle while the metered lane is commanded by default settings (value of the rmcImplementCommandSource-object is 'default'). This value shall be expressed in 1- vehicle increments. A suggested usable range is 1 to 5. number 1.3.6.1.4.1.1206.4.2.2.3.1.7.1.17" REFERENCE "See Clause A.3" ::={ rmcMeterCtrlEntry 17 } rmcDemandMode OBJECT-TYPE SYNTAX INTEGER { recalled (1), enabledCall (2), enabledStop (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the mode of the demand detector. recalled - indicates that the demand detector will constantly place a call even without a vehicle being present in its detection zone. enabledCall - indicates that the demand detector is ready to detect, and shall constantly place a call when it has failed. enabledStop - indicates that the demand detector is ready to detect, and shall exit the Metering state when it has failed. 1.3.6.1.4.1.1206.4.2.2.3.1.7.1.18" REFERENCE "See Clause A.2.2.1, A.8.3.1.4.1 and A.8.5.3.4.1" ::={ rmcMeterCtrlEntry 18 } rmcPreMeterNonGreen OBJECT-TYPE SYNTAX INTEGER { other (1), allDark (2), flashYellow (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates which signal indication(s) for the metered lane shall be ON during the Pre-metering Non-green interval. other - indicates that the red, yellow and green indications used are not defined in NTCIP 1207 v02. allDark - indicates that the red, yellow and green indications will be OFF. flashYellow - indicates that the yellow indication will be flashed, and the red and green indications will be OFF. Reference MUTCD 2003, revision 1, section 4D.11. 1.3.6.1.4.1.1206.4.2.2.3.1.7.1.19" REFERENCE "See Clause A.2.2" ::={ rmcMeterCtrlEntry 19 } rmcCritFlowRateThresh OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the critical flow rate threshold to be used to supercede queue adjustment during traffic-responsive metering. This value shall be expressed in 1-vph increments. A suggested usable range is 0, 1000 to 3600. A value of zero (0) indicates that this threshold shall NOT be used to supercede queue adjustment during traffic-responsive metering. vehicles per hour 1.3.6.1.4.1.1206.4.2.3.1.7.1.20" REFERENCE "See Clause A.4.3" ::={ rmcMeterCtrlEntry 20 } rmcCritOccupancyThresh OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the critical occupancy threshold to be used to supercede queue adjustment during traffic-responsive metering. This value shall be expressed in 0.1-percent increments (i.e, 40 = 4.0 percent). A suggested usable range is 0 and 50 to 300. A value of zero (0) indicates that this threshold shall NOT be used to supercede queue adjustment during traffic-responsive metering. tenth of percent 1.3.6.1.4.1.1206.4.2.3.1.7.1.21" REFERENCE "See Clause A.4.3" ::={ rmcMeterCtrlEntry 21 } rmcCriticalSpeedThreshold OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the critical speed threshold to be used to supercede queue adjustment during traffic-responsive metering. This value shall be expressed in 1-km/h increments. A suggested usable range is 0, 15 to 100. A value of zero (0) indicates that this threshold shall NOT be used to supercede queue adjustment during traffic-responsive metering. kilometer per hour 1.3.6.1.4.1.1206.4.2.3.1.7.1.22" REFERENCE "See Clause A.4.3" ::={ rmcMeterCtrlEntry 22 } rmcMeterStatTable OBJECT-TYPE SYNTAX SEQUENCE OF RmcMeterStatEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing the status information for a metered lane.
static 1.3.6.1.4.1.1206.4.2.2.3.1.8" ::={ rmcMeterMain 8 } rmcMeterStatEntry OBJECT-TYPE SYNTAX RmcMeterStatEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Status parameters of the metered lanes status table. This table is directly correlated to the Metered Lane Control Table, which means that the number of rows in this table is exactly the same as the number of rows in the Metered Lane Control Table (AUGMENT TABLE in SNMPv2 terminology). Table management can only take place through the Metered Lane Control Table, while this table provides status information for the associated metered lane. 1.3.6.1.4.1.1206.4.2.2.3.1.8.1" INDEX { rmcMeterNumber } ::={ rmcMeterStatTable 1 } RmcMeterStatEntry ::=SEQUENCE { rmcRequestCommandSource INTEGER, rmcImplementCommandSource INTEGER, rmcImplementAction INTEGER, rmcImplementPlan INTEGER, rmcImplementRate INTEGER, rmcImplementVehiclesPerGrn INTEGER, rmcRequestAction INTEGER, rmcRequestPlan INTEGER, rmcRequestRate INTEGER, rmcRequestVehiclesPerGrn INTEGER, rmcCommActionStatus INTEGER, -- changed name only in version 2 rmcBaseMeterRate INTEGER, rmcActiveMeterRate INTEGER, rmcTBActionStatus INTEGER, rmcTBPlanStatus INTEGER, rmcTBRateStatus INTEGER, rmcTBVehiclesPerGrnStatus INTEGER, rmcActiveInterval INTEGER, rmcTBCMinMeterRateStatus INTEGER, rmcTBCMaxMeterRateStatus INTEGER, rmcOperMinMeterRateStatus INTEGER, -- deprectated in version 2 rmcOperMinMeterRateStatusV2 INTEGER, -- added in version 2 rmcOperMaxMeterRateStatus INTEGER, -- deprectated in version 2 rmcOperMaxMeterRateStatusV2 INTEGER, -- added in version 2 rmcDemandStatus INTEGER, rmcHistDemandStatus INTEGER, -- added in version 2 rmcCycleCount INTEGER, -- added in Version 2 rmcCumulQueAdjStat INTEGER, –- added in version 2 rmcMainQueueFlag INTEGER –- added in version 2 } rmcRequestCommandSource OBJECT-TYPE SYNTAX INTEGER { manual (1), communications (2), interconnect (3), timebaseControl (4), default (5) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the command source that requests control of this metered lane. The values are: manual - the metered lane is requested to be controlled locally at the site. communications - the metered lane is requested to be controlled by the central system. This usually means that the entire RMC is controlled centrally. interconnect - the metered lane is requested to be controlled by an on-street master controller. timebaseControl - the metered lane is requested to be controlled using values as selected via the Timebase Control Action table. default - indicates that the metered lane is requested to be controlled using default settings. 1.3.6.1.4.1.1206.4.2.2.3.1.8.1.1" REFERENCE "See Clause A.3" ::={ rmcMeterStatEntry 1 } rmcImplementCommandSource OBJECT-TYPE SYNTAX INTEGER { manual (1), communications (2), interconnect (3), timebaseControl (4), default (5) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the command source that currently controls this metered lane. The values are: manual - the metered lane is currently controlled locally at the site. communications - the metered lane is currently controlled by the central system. This usually means that the entire RMC is controlled centrally. interconnect - the metered lane is currently controlled by an on-street master controller. timebaseControl - the metered lane is currently controlled using values as selected via the Timebase Control Action table. default - indicates that the metered lane is currently controlled using default settings. 1.3.6.1.4.1.1206.4.2.2.3.1.8.1.2" REFERENCE "See Clause A.3" ::={ rmcMeterStatEntry 2 } rmcImplementAction OBJECT-TYPE SYNTAX INTEGER { dark (1), restInGreen (2), fixedRate (3), trafficResponsive (4), emergencyGreen (5), holdMeter (6), holdNonMeter (7), holdRestInGreen (8) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the action that is active for the metered lane. The values are: dark - indicates that the metered lane will advance to the Pre-Metering Non-Green interval. restInGreen - indicates that the metered lane will advance to the Pre-Metering Green interval. fixedRate - indicates that the metered lane will operate using the value of the rmcImplementRate-object. trafficResponsive -indicates that the metered lane will operate using mainline station traffic conditions and the value of the rmcImplementPlan-object. emergencyGreen - indicates that the metered lane will advance to and remain in the Post-metering Green interval without entering the Shutdown Green, Shutdown Yellow, Shutdown Red or Shutdown Warning intervals when the metered lane is NOT in the Non-metering state. The metered lane will advance to the Pre-Metering Green interval when the metered lane is in the Non-metering state. holdMeter - indicates that the metered lane will remain in the metering state regardless of the requested action (rmcRequestedAction-object) due to restrictions such as minimum metering times. holdNonMeter - indicates that the metered lane will remain in the non-metering state regardless of the requested action (rmcRequestedAction-object) due to restrictions such as minimum non-metering times. holdRestInGreen - indicates that the metered lane was forced into the Pre-Metering Green interval because another lane within this Dependency Group is NOT in the non-metering state. 1.3.6.1.4.1.1206.4.2.2.3.1.8.1.3" REFERENCE "See Clause A.3, A.5.1, A.5.2, A.6.1, A.6.2, A.6.3 and A.7.2" ::={ rmcMeterStatEntry 3 } rmcImplementPlan OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the metering plan number that is implemented if the rmcImplementAction-object has a value of 'trafficResponsive'. This value shall not exceed the value of the rmcMaxNumMeteringPlans-object nor that of the rmcNumMeterPlans-object. number 1.3.6.1.4.1.1206.4.2.2.3.1.8.1.4" REFERENCE "See Clause A.5.2 and A.7.2" ::={ rmcMeterStatEntry 4 } rmcImplementRate OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the base metering rate if the rmcImplementAction-object has a value of 'fixedRate'. This value shall be expressed in 1-vph increments. number 1.3.6.1.4.1.1206.4.2.2.3.1.8.1.5" ::={ rmcMeterStatEntry 5 } rmcImplementVehiclesPerGrn OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the number of vehicles that are currently allowed to pass during the green and yellow intervals of one cycle. This value shall be expressed in 1-vehicle increments. vehicles per hour 1.3.6.1.4.1.1206.4.2.2.3.1.8.1.6" REFERENCE "See Clause A.3, A.8.3.2.1 and A.8.5.1.1" ::={ rmcMeterStatEntry 6 } rmcRequestAction OBJECT-TYPE SYNTAX INTEGER { dark (1), restInGreen (2), fixedRate (3), trafficResponsive (4), emergencyGreen (5) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the action that is requested for this metered lane. The values are: dark - indicates that the metered lane is requested to advance to the Pre-Metering Non-Green interval. restInGreen - indicates that the metered lane is requested to advance to the Pre-Metering Green interval. fixedRate - indicates that the metered lane is requested to operate using the value of the rmcRequestRate-object. trafficResponsive -indicates that the metered lane is requested to operate using mainline station traffic conditions and the value of the rmcRequestPlan-object. emergencyGreen - indicates that the metered lane is requested to advance to and remain in the Post-metering Green interval without entering the Shutdown Green, Shutdown Yellow, Shutdown Red or Shutdown Warning intervals when the metered lane is NOT in the Non-metering state. The metered lane shall advance to the Pre-Metering Green interval when the metered lane is in the Non-metering state. 1.3.6.1.4.1.1206.4.2.2.3.1.8.1.7" REFERENCE "See Clause A.3" ::={ rmcMeterStatEntry 7 } rmcRequestPlan OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the metering plan number that is requested if the rmcRequestAction- object has a value of 'trafficResponsive'. This value shall not exceed the value of the rmcMaxNumMeterPlans-object. number 1.3.6.1.4.1.1206.4.2.2.3.1.8.1.8" REFERENCE "See Clause A.3" ::={ rmcMeterStatEntry 8 } rmcRequestRate OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the metering rate that is requested if the rmcRequestAction-object has a value of 'fixedRate'. This value shall be expressed in 1-vph increments. vehicles per hour 1.3.6.1.4.1.1206.4.2.2.3.1.8.1.9" ::={ rmcMeterStatEntry 9 } rmcRequestVehiclesPerGrn OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the number of vehicles that has been requested to pass during the green and yellow intervals of one cycle. This value shall be expressed in 1-vehicle increments. number 1.3.6.1.4.1.1206.4.2.2.3.1.8.1.10" REFERENCE "See Clause A.3" ::={ rmcMeterStatEntry 10 } rmcCommActionStatus OBJECT-TYPE SYNTAX INTEGER { dark (1), restInGreen (2), fixedRate (3), trafficResponsive (4), emergencyGreen (5), skip (6), noComm (7) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the requested action if the metered lane is commanded by communications. If the value of this object is NOT 'noComm', then the action is directly determined by the value of the rmcCommActionMode-object. The values are: dark - indicates that the metered lane will advance to the Pre-Metering Non-Green interval. restInGreen - indicates that the metered lane will advance to the Pre-Metering Green interval. fixedRate - indicates that the metered lane will operate using the value of the rmcCommRate-object. trafficResponsive -indicates that the metered lane will operate using mainline station traffic conditions and the value of the rmcCommPlan-object. emergencyGreen - indicates that the metered lane will advance to the Post-metering Green interval without entering the Shutdown Green, Shutdown Yellow, Shutdown Red or Shutdown Warning intervals when the metered lane is NOT in the Non-metering state. The metered lane will advance to the Pre-Metering Green interval when the metered lane is in the Non-metering state. skip - indicates that the next-lower level command source shall be considered as specified by the rmcCmdSourcePriorityOrder-object. noComm - indicates that communications to the device is lost (device timed out based on the value of the rmcCommRefreshThreshold-object); the action associated with this state is that the next-lower level command source shall be considered as specified by the rmcCmdSourcePriorityOrder-object. 1.3.6.1.4.1.1206.4.2.2.3.1.8.1.11" REFERENCE "See Clause A.3" ::={ rmcMeterStatEntry 11 } -- USERS TAKE NOTE OF MULTIPLE VERSIONS - -- the object name was changed from ‘rmcCommAction’ to -- ‘rmcCommActionStatus’. This should not cause any backwards -- compatibility problems. rmcBaseMeterRate OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the metering rate for this metered lane PRIOR to any RATE adjustments. This value shall be expressed in 1-vph increments. vehicles per hour 1.3.6.1.4.1.1206.4.2.2.3.1.8.1.12" REFERENCE "See Clause A.3" ::={ rmcMeterStatEntry 12 } rmcActiveMeterRate OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the metering rate for this metered lane AFTER all RATE adjustments. This value shall be expressed in 1-vph increments. vehicles per hour 1.3.6.1.4.1.1206.4.2.2.3.1.8.1.13" REFERENCE "See Clause A.3" ::={ rmcMeterStatEntry 13 } rmcTBActionStatus OBJECT-TYPE SYNTAX INTEGER { dark (1), restInGreen (2), fixedRate (3), trafficResponsive (4), emergencyGreen (5), skip (6) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the action that may be active if the metered lane is controlled by timebase control. This object is used to indicate the status of the entry, while the rmcTBActionCtrl-object allows to control the entry. The values are: dark - indicates that the metered lane will advance to the Pre-Metering Non-Green interval. restInGreen - indicates that the metered lane will advance to the Pre-Metering Green interval. fixedRate - indicates that the metered lane will operate using the value of the rmcTBRateStatus-object. trafficResponsive -indicates that the metered lane will operate using mainline station traffic conditions and the value of the rmcTBPlanStatus-object. emergencyGreen - indicates that the metered lane will advance to the Post-metering Green interval without entering the Shutdown Green, Shutdown Yellow, Shutdown Red or Shutdown Warning intervals when the metered lane is NOT in the Non-metering state. The metered lane will advance to the Pre-Metering Green interval when the metered lane is in the Non-metering state. skip - indicates that the next-lower level command source shall be considered as specified by the rmcCmdSourcePriorityOrder-object. 1.3.6.1.4.1.1206.4.2.2.3.1.8.1.14" REFERENCE "See Clause A.3.1" ::={ rmcMeterStatEntry 14 } rmcTBPlanStatus OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the requested metering plan number if the metered lane is commanded by timebase control and the rmcRequestedAction-object has a value of 'trafficResponsive'. This value cannot exceed the value of the rmcMaxNumMeterPlans-object. This object is used to indicate the status of the entry, while the rmcTBPlanCtrl-object allows control of the entry. number 1.3.6.1.4.1.1206.4.2.2.3.1.8.1.15" REFERENCE "See Clause A.3.1" ::={ rmcMeterStatEntry 15 } rmcTBRateStatus OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the requested metering rate if the metered lane is commanded by timebase control and the rmcRequestAction-object has a value of 'fixedRate'. This object is used to indicate the status of the entry, while the rmcTBPlanCtrl-object allows control of the entry. This value shall be expressed in 1-vph increments. vehicles per hour 1.3.6.1.4.1.1206.4.2.2.3.1.8.1.16" REFERENCE "See Clause A.3.1" ::={ rmcMeterStatEntry 16 } rmcTBVehiclesPerGrnStatus OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the requested number of vehicles to pass during the green and yellow intervals of one cycle while the metered lane is commanded by timebase control. This object is used to indicate the status of the entry, while the rmcTBVehiclesPerGrnCtrl-object allows control of the entry. This value shall be expressed in 1-vph increments. A suggested usable range is 1 to 5. number 1.3.6.1.4.1.1206.4.2.2.3.1.8.1.17" REFERENCE "See Clause A.3.1" ::={ rmcMeterStatEntry 17 } rmcActiveInterval OBJECT-TYPE SYNTAX INTEGER { initialization (1), preMeteringNonGreen (2), preMeteringGreen (3), startupAlert (4), startupWarning (5), startupGreen (6), startupYellow (7), startupRed (8), red (9), green (10), yellow (11), shutdownGreen (12), shutdownYellow (13), shutdownRed (14), shutdownWarning (15), postMeteringGreen (16) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the interval in which the metered lane is currently running. See the State Diagram (Figure 3) as displayed in Section 1.4 and Annex A for further explanations of the different values. 1.3.6.1.4.1.1206.4.2.2.3.1.8.1.18" REFERENCE "See Clause A.2.2" ::={ rmcMeterStatEntry 18 } rmcTBCMinMeterRateStatus OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the operational minimum metering rate, in vph. This object is used to indicate the status of the entry, while the rmcTBCMinMeterRateCtrl-object allows control of the entry. This value shall be expressed in 1-vph increments. A value of zero (0) indicates this parameter is not used. vehicles per hour 1.3.6.1.4.1.1206.4.2.2.3.1.8.1.19" REFERENCE "See Clause A.3.1" ::={ rmcMeterStatEntry 19 } rmcTBCMaxMeterRateStatus OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the operational maximum metering rate, in vph. This object is used to indicate the status of the entry, while the rmcTBCMaxMeterRateCtrl-object allows control of the entry. This value shall be expressed in 1-vph increments. A value of zero (0) indicates this parameter is not used. The value, if non-zero, shall be greater than or equal to the value of the rmcOperMinMeterRateStatus-object. vehicles per hour 1.3.6.1.4.1.1206.4.2.2.3.1.8.1.20" REFERENCE "See Clause A.3.1" ::={ rmcMeterStatEntry 20 } rmcOperMinMeterRateStatus OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS deprecated DESCRIPTION "Indicates the operational minimum metering rate, in vph. This object indicates the minimum of the maximum metering rate objects (rmcAbsoluteMaxMeterRate, rmcSystemMaxMeterRate, rmcTBCMaxMeterRateStatus) that is currently active of this metered lane. vehicles per hour 1.3.6.1.4.1.1206.4.2.2.3.1.8.1.21" REFERENCE "See Clause A.2.2" ::={ rmcMeterStatEntry 21 } -- this object was deprectated because its description is incorrect. Another -- object with the same information but the correct description was created. rmcOperMinMeterRateStatusV2 OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the operational minimum metering rate, in vph. The value of this object is the maximum value of the minimum metering rate objects (rmcAbsoluteMinMeterRate-object, rmcSystemMinMeterRate-object, rmcTBCMinMeterRateStatus-object) that is currently active for this metered lane. This value shall be expressed in 1-vph increments. vehicles per hour 1.3.6.1.4.1.1206.4.2.2.3.1.8.1.26" REFERENCE "See Clause A.2.2" ::={ rmcMeterStatEntry 26 } -- this object was created because the description of the original object was -- incorrect. rmcOperMaxMeterRateStatus OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS deprecated DESCRIPTION "Indicates the operational maximum metering rate, in vph. This object indicates the maximum of the minimum metering rate objects (rmcAbsoluteMinMeterRate, rmcSystemMinMeterRate, rmcTBCMinMeterRateStatus) that is currently active of this metered lane. This value shall be expressed in 1-vph increments. vehicles per hour 1.3.6.1.4.1.1206.4.2.2.3.1.8.1.22" REFERENCE "See Clause A.2.2" ::={ rmcMeterStatEntry 22 } -- this object was deprectated because its description is incorrect. Another -- object with the same information but the correct description was created. rmcOperMaxMeterRateStatusV2 OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the operational maximum metering rate, in vph. The value of this object is the minimum value of the maximum metering rate objects (rmcAbsoluteMaxMeterRate-object, rmcSystemMaxMeterRate-object, rmcTBCMaxMeterRateStatus-object) that is currently active for this metered lane. This value shall be expressed in 1-vph increments. vehicles per hour 1.3.6.1.4.1.1206.4.2.2.3.1.8.1.27" REFERENCE "See Clause A.2.2" ::={ rmcMeterStatEntry 27 } -- this object was created because the description of the original object was -- incorrect. rmcDemandStatus OBJECT-TYPE SYNTAX INTEGER { recalled (1), working (2), otherError (3), erraticCount (4), maxPresence (5), noActivity (6), errorAtSensor (7), depNoActivity (8), -- added in version 2 depMaxPresence (9) -- added in version 2 } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the status of the demand detector. The values are: recalled - indicates that the value of the rmcDemandMode-object is 'recalled'. working - indicates that this detector has no error. otherError - indicates an error not defined here. See Operator's manual. erraticCount - indicates that the vehicle count for this detector has exceeded the value of its rmcDemandErraticCount-object. maxPresence - indicates a continuous actuation for this detector that has exceeded the value of its rmcDemandMaxPresence-object. noActivity - indicates a continuous non-actuation for this detector that has exceeded the value of its rmcDemandNoActivity-object. errorAtSensor - indicates that the sensor for this detector has reported an error. See Operator's manual. depNoActivity - indicates a continuous non-actuation for this detector, while a count of vehicles on the passage detector in the same metered lane that has exceeded the value of its rmcDemandDependNoActivity-object. depMaxPresence - indicates a continuous actuation for this detector, while a continuous non-actuation of the passage detector in the same metered lane that has exceeded the value of its rmcDemandDependMaxPresence-object. The test results expressed by values 2, 4, 5, 6, 7, 8, and 9 are only meaningful, when rmcDemandMode is NOT 'Recalled'. 1.3.6.1.4.1.1206.4.2.2.3.1.8.1.23" REFERENCE "See Clause A.2.2.1, A.8.3.1.4.1 and A.8.5.3.4.1" ::={ rmcMeterStatEntry 23 } rmcHistDemandStatus OBJECT-TYPE SYNTAX INTEGER (0..65535) -- BITMAP16 ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the cumulative status of the demand detector. Status values are indicated as follows: Bit Number Name Description Bit 15: reserved. Bit 14: reserved. Bit 13: reserved. Bit 12: reserved. Bit 11: reserved. Bit 10: reserved. Bit 09: reserved. Bit 08: Dependent Max Presence – the rmcDemandStatus-object has or had a value of ‘depMaxPresence’ since reset. Bit 07: Dependent No activity – the rmcDemandStatus-object has or had a value of ‘depNoActivity’ since reset. Bit 06: Error at Sensor – the rmcDemandStatus-object has or had a value of ‘errorAtSensor’ since reset. Bit 05: No activity – the rmcDemandStatus-object has or had a value of ‘noActivity’ since reset. Bit 04: Max presence – the rmcDemandStatus-object has or had a value of ‘maxPresence’ since reset. Bit 03: Erratic count – the rmcDemandStatus-object has or had a value of ‘erraticCount’ since reset. Bit 02: Other error – the rmcDemandStatus-object has or had a value of ‘otherError’ since reset. Bit 01: Working – the rmcDemandStatus-object has or had a value of ‘working’ since reset. Bit 00: Disabled – the rmcDemandStatus-object has or had a value of ‘disabled’ since reset. In the context of this object, ‘reset’ means either an initialization of the RMC or a successful SET of the rmcHistDetectorReset-object. When a ‘reset’ occurs, all bits shall be set to 0. All reserved bits shall always be set to zero (0). A bad value error shall be returned, if a management application writes a one (1) to any of the reserved bits. 1.3.6.1.4.1.1206.4.2.2.3.1.8.1.24" REFERENCE "See Clause A.2.2.1" ::={ rmcMeterStatEntry 24 } rmcCycleCount OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " Indicates the count of the number of green intervals in the most recently completed calculation interval. Counts are expressed as an integer value. The value of 255 shall be returned to represent a missing value. number 1.3.6.1.4.1.1206.4.2.2.3.1.8.1.25" REFERENCE "See Clause A.2.2" ::={ rmcMeterStatEntry 25 } rmcCumulQueAdjStat OBJECT-TYPE SYNTAX INTEGER { none (1), adjust (2), override (3) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether queue adjustment is currenly being applied to the metering rate of the lane. none - indicates that no queue adjustment is currently being applied. adjust - indicates that queue adjustment is currently being applied. override - indicates that the queue adjustment is overridden for this lane. 1.3.6.1.4.1.1206.4.2.2.3.1.8.1.28" REFERENCE "See Clause A.2.2.3" ::={ rmcMeterStatEntry 28 } rmcMainQueueFlag OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether mainline detector station traffic conditions supercede queue adjustment for the lane. 0 = false – mainline traffic conditions do not supercede queue adjustment for the lane. 1 = true - mainline traffic conditions supercede queue adjustment for the lane. 1.3.6.1.4.1.1206.4.2.2.3.1.8.1.29" REFERENCE "See Clause A.4.3" ::={ rmcMeterStatEntry 29 } rmcDependGroup OBJECT IDENTIFIER ::={ rmcMeter 2} rmcMaxNumDependGroup OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the maximum number of dependency groups that can be stored in the rmcDependGroupCtrlTable-object, and, by association, in all other dependency group tables. At least one dependency group shall be defined. number 1.3.6.1.4.1.1206.4.2.2.3.2.1" REFERENCE "See Clause A.2.3" ::={ rmcDependGroup 1 } -- USERS TAKE NOTE OF MULTIPLE VERSIONS - -- the ACCESS was changed to start from ‘read-write’ to ‘read-only’. -- This is because number of dependency groups cannot be changed remotely as -- the description indicates. This was incorrect in Version 1. -- This does not cause backwards compatibility problems. rmcNumDependGroup OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the actual number of dependency groups that are present in the rmcDependGroupCtrlTable-object, and, by association, in all other dependency group tables. This value shall not exceed the value of the rmcMaxNumDependGroup–object. number 1.3.6.1.4.1.1206.4.2.2.3.2.2" REFERENCE "See Clause A.2.3" ::={ rmcDependGroup 2 } -- USERS TAKE NOTE OF MULTIPLE VERSIONS - -- the ACCESS was changed from ‘read-write’ to ‘read-only’. -- This is because the number of dependency groups cannot be changed remotely -- as the description indicates. This was incorrect in Version 1. -- This does not cause backwards compatibility problems. rmcDependGroupCtrlTable OBJECT-TYPE SYNTAX SEQUENCE OF RmcDependGroupCtrlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing the configuration and control information for a dependency group.
static 1.3.6.1.4.1.1206.4.2.2.3.2.3" ::={ rmcDependGroup 3 } rmcDependGroupCtrlEntry OBJECT-TYPE SYNTAX RmcDependGroupCtrlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Configuration and control parameters of the dependency group table. At least one dependency group shall be defined. A particular row of this table can be managed using the rmcDependGroupMode-object. There is a one-to-one relationship between the values of the rmcDependGroupNumber-object within the rmcMeterCfgTable-object and the number of rows within this table. Each different value represents one row of this table. 1.3.6.1.4.1.1206.4.2.2.3.2.3.1" INDEX { rmcDependGroupNumber } ::={ rmcDependGroupCtrlTable 1 } RmcDependGroupCtrlEntry ::=SEQUENCE { rmcDependGroupMode INTEGER, rmcSignalServiceMode INTEGER, rmcShutGapTime INTEGER, rmcShutGapReductTime INTEGER, rmcShutGapReductValue INTEGER, rmcGreenOffset INTEGER, rmcMinFractionalOffset INTEGER, rmcPriorityLaneNum INTEGER, rmcPriorityRedDelay INTEGER, rmcMergeMode INTEGER, rmcMergeGap INTEGER, rmcMergeDelay INTEGER, rmcQueueMergeFlag INTEGER, rmcMergeErraticCount INTEGER, rmcMergeMaxPresence INTEGER, rmcMergeNoActivity INTEGER, rmcMinMutexRed INTEGER –- added in version 2 } rmcDependGroupMode OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates whether the associated dependency group is used. 0 = disabled - the dependency group is not used. 1 = enabled - the dependency group is used. 1.3.6.1.4.1.1206.4.2.2.3.2.3.1.1" REFERENCE "See Clause A.2.3" ::={ rmcDependGroupCtrlEntry 1 } rmcSignalServiceMode OBJECT-TYPE SYNTAX INTEGER { none (1), mutex (2), fixedOffset (3), fractionalOffset (4) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the signal service mode associated with this dependency group. The values are: none - there is no dependency between the lanes within this dependency group. mutex - one and only lane in the dependency group shall display (or indicate)green at any given time during the Metering state. fixedOffset - the start of the green interval for any lane will occur no sooner than indicated in the value of the rmcGreenOffset-object after the start of a previous green interval for a lane in the same dependency group. fractionalOffset - the start of the green interval for any lane will occur no sooner than indicated in the value of the rmcRequestCycleLength-object divided by the number of metered lanes in the dependency group, after the start of a previous green interval for a lane in the same dependency group. 1.3.6.1.4.1.1206.4.2.2.3.2.3.1.2" REFERENCE "See Clause A.2.3.2, A.3, A.8.2.2, A.8.3.1.3, A.8.3.1.4.1, A.8.5.3.3, A.8.5.3.4.1, A.8.5.3.5 and A.8.6.3" ::={ rmcDependGroupCtrlEntry 2 } rmcShutGapTime OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the length of time between successive actuations of demand detectors necessary to terminate the shutdown metering. This value shall be expressed in 0.1-second increments (i.e, 40 = 4.0 seconds). A suggested usable range is 0 and 10 to 100. A value of zero (0) shall make the termination of shutdown metering dependent only on the shutdown time. tenth of second 1.3.6.1.4.1.1206.4.2.2.3.2.3.1.3" REFERENCE "See Clause A.8.2.1 and A.8.5.3.5" ::={ rmcDependGroupCtrlEntry 3 } rmcShutGapReductTime OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the amount of time between reduction iterations for the shutdown gap time. This value shall be expressed in 0.1-second increments (i.e, 40 = 4.0 seconds). A suggested usable range is 10 to 200. tenth of second 1.3.6.1.4.1.1206.4.2.2.3.2.3.1.4" REFERENCE "See Clause A.8.5.3.5" ::={ rmcDependGroupCtrlEntry 4 } rmcShutGapReductValue OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the amount of time that the shutdown gap time is reduced for each iteration. This value shall be expressed in 0.1-seconds increments (i.e, 40 = 4.0 seconds). A suggested usable range is 10 to 100. A value of ‘0’ shall inhibit shutdown gap time reduction. tenth of second 1.3.6.1.4.1.1206.4.2.2.3.2.3.1.5" REFERENCE "See Clause A.8.5.3.5" ::={ rmcDependGroupCtrlEntry 5 } rmcGreenOffset OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the length of time between the beginning of successive green intervals for metered lanes that have the same value for the rmcDependGroupNumber-object (combined in the same dependency group) and a value of 'fixedOffset' for the rmcSignalServiceMode-object. This value shall be expressed in 0.1-second increments (i.e, 40 = 4.0 seconds). A suggested usable range is 5 to 100. tenth of second 1.3.6.1.4.1.1206.4.2.2.3.2.3.1.6" REFERENCE "See Clause A.2.3.2, A.8.3.4.1 and A.8.5.3.4.1" ::={ rmcDependGroupCtrlEntry 6 } rmcMinFractionalOffset OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the minimum length of time between the beginning of successive green intervals for metered lanes that have the same value for the rmcDependGroupNumber-object (combined in the same dependency group) and a value of 'fractionalOffset' for the rmcSignalServiceMode-object. This value shall be expressed in 0.1-second increments(i.e, 40 = 4.0 seconds). A suggested usable range is 0 and 5 to 50. A value of zero (0) shall indicate that this parameter does not represent a constraint. tenth of second 1.3.6.1.4.1.1206.4.2.2.3.2.3.1.7" REFERENCE "See Clause A.2.3.2, A.8.3.4.1 and A.8.5.3.4.1" ::={ rmcDependGroupCtrlEntry 7 } rmcPriorityLaneNum OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates which metered lane in the dependency group lane sequence shall be treated as a priority lane. The value shall not exceed the value of the rmcMaxNumMeterLanes-object. A value of zero (0) indicates the absence of a priority lane in this dependency group. number 1.3.6.1.4.1.1206.4.2.2.3.2.3.1.8" REFERENCE "See Clause A.2.3.2, A.8.3.1.3 and A.8.5.3.3" ::={ rmcDependGroupCtrlEntry 8 } rmcPriorityRedDelay OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the minimum length of the red interval for each metered lane in the dependency group (if is NOT marked as the priority lane), when the demand detector of the priority lane is actuated. The purpose of this object is to give a vehicle in the priority lane a headway of at least the time indicated in this object. For each actuation of the demand detector in the priority lane and each metered lane, the value of this object shall only apply once. This value shall be expressed in 0.1-second increments(i.e, 40 = 4.0 seconds). A suggested usable range is 0 to 50. tenth of second 1.3.6.1.4.1.1206.4.2.2.3.2.3.1.9" REFERENCE "See Clause A.8.3.1.3 and A.8.5.3.3" ::={ rmcDependGroupCtrlEntry 9 } rmcMergeMode OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the mode of the merge detector . The values are: 0 = disabled - indicates that the merge detector does not exist for this dependency group. 1 = enabled - indicates that the merge detector is ready to detect for this dependency group. 1.3.6.1.4.1.1206.4.2.2.3.2.3.1.10" REFERENCE "See Clause A.2.3.1" ::={ rmcDependGroupCtrlEntry 10 } rmcMergeGap OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the length of time between successive actuations of the merge detector necessary to terminate the merge override condition( value of the rmcMergeFlag-object is set to 'false'). This value shall be expressed in 0.1-second increments(i.e, 40 = 4.0 seconds). A suggested usable range is 0 to 255. A value of ‘0’ shall force the Merge Override Flag to be ‘False’ while the merge detector is not actuated. tenth of second 1.3.6.1.4.1.1206.4.2.2.3.2.3.1.11" REFERENCE "See Clause A.8.4.1" ::={ rmcDependGroupCtrlEntry 11 } rmcMergeDelay OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the length of time for continuous presence on the merge detector necessary to identify the merge override condition. If presence is detected for a duration equal to or greater than indicated by the value of this object, the value of the rmcMergeFlag-object will be set to 'true', which will inhibit the termination of the red interval for all metered lanes in this dependency group. This value shall be expressed in 0.1-second increments(i.e, 40 = 4.0 seconds). A suggested usable range is 0 to 255. A value of ‘0’ shall force the Merge Override Flag to be ‘False’ while the merge detector is actuated. tenth of second 1.3.6.1.4.1.1206.4.2.2.3.2.3.1.12" REFERENCE "See Clause A.8.4.1" ::={ rmcDependGroupCtrlEntry 12 } rmcQueueMergeFlag OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates if queue override adjustments are given priority over merge override adjustment. 0 = false - merge override adjustment is given priority over queue override adjustments. 1 = true - queue override adjustments are given priority over merge override adjustment. 1.3.6.1.4.1.1206.4.2.2.3.2.3.1.13" REFERENCE "See Clause A.8.3.1.4.1, A.8.3.1.4.2, A.8.4.1, A.8.5.3.4.1 and A.8.5.3.4.2" ::={ rmcDependGroupCtrlEntry 13 } rmcMergeErraticCount OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "If the vehicle count, over the most recently completed calculation interval, on the merge detector for a metered lane exceeds this threshold, the rmcMergeStatus-object shall be set to a value of 'erraticCount'. This value shall be expressed in 1-vehicle increments. A suggested usable range is 0 to 30. A value of zero (0) shall inhibit the erratic count testing. number 1.3.6.1.4.1.1206.4.2.2.3.2.3.1.14" REFERENCE "See Clause A.2.3.1" ::={ rmcDependGroupCtrlEntry 14 } rmcMergeMaxPresence OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "If the input on the merge detector for this metered lane has been continuously actuated for longer than the time indicated by this threshold, the rmcMergeStatus-object shall be set to a value of 'maxPresence'. This value shall be expressed in 1-minute increments. A suggested usable range is 0 to 1500. A value of zero (0) shall inhibit the maximum presence testing. minute 1.3.6.1.4.1.1206.4.2.2.3.2.3.1.15" REFERENCE "See Clause A.2.3.1" ::={ rmcDependGroupCtrlEntry 15 } rmcMergeNoActivity OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "If the input on the merge detector for this metered lane has not been actuated for longer than the time indicated by this threshold, the rmcMergeStatus-object shall be set to a value of 'noActivity'. This value shall be expressed in 1-minute increments. A suggested usable range is 0 to 1500. A value of zero (0) shall inhibit the no activity testing. minute 1.3.6.1.4.1.1206.4.2.2.3.2.3.1.16" REFERENCE "See Clause A.2.3.1" ::={ rmcDependGroupCtrlEntry 16 } rmcMinMutexRed OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the minimum amount of time that all metered lanes in the dependency group shall simultaneously remain in the Red or Shutdown Red intervals. This value shall be expressed in 0.1-second increments (i.e, 40 = 4.0 seconds). A suggested usable range is 10 to 100. A value of ‘0’ shall indicate that no minimum simultaneous red time is required. tenth of second 1.3.6.1.4.1.1206.4.2.2.3.2.3.1.17" REFERENCE "See Clause A.8.3.1.4.1, A.8.5.3.4" ::={ rmcDependGroupCtrlEntry 17 } rmcDependGroupStatTable OBJECT-TYPE SYNTAX SEQUENCE OF RmcDependGroupStatEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing the status information for a dependency group.
static 1.3.6.1.4.1.1206.4.2.2.3.2.4" ::={ rmcDependGroup 4 } rmcDependGroupStatEntry OBJECT-TYPE SYNTAX RmcDependGroupStatEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Status information of the dependency group table. This table is directly correlated to the Dependency Group Configuration and Control Table, which means that the number of rows in this table is exactly the same as the number of rows in the Dependency Group Configuration and Control Table (AUGMENT TABLE in SNMPv2 terminology). Table management can only take place through the Dependency Group Configuration and Control Table, while this table provides status information for the associated dependency group. 1.3.6.1.4.1.1206.4.2.2.3.2.4.1" INDEX { rmcDependGroupNumber } ::={ rmcDependGroupStatTable 1 } RmcDependGroupStatEntry ::=SEQUENCE { rmcMergeFlag INTEGER, rmcMergeStatus INTEGER, rmcHistMergeStatus INTEGER, -- added in version 2 rmcMergeOverStat INTEGER -- added in version 2 } rmcMergeFlag OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether merge override conditions exist. 0 = false - indicates that no merge override conditions exist. 1 = true - indicates that merge override conditions exist. 1.3.6.1.4.1.1206.4.2.2.3.2.4.1.1" REFERENCE "See Clause A.2.2.1, A.2.2.3, A.2.3.1, A.8.3.1.4.1, A.8.3.1.4.2, A.8.4.1, A.8.5.3.4.1 and A.8.5.3.4.2" ::={ rmcDependGroupStatEntry 1 } rmcMergeStatus OBJECT-TYPE SYNTAX INTEGER { disabled (1), working (2), otherError (3), erraticCount (4), maxPresence (5), noActivity (6), errorAtSensor (7) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the status of the merge detector. The values are: disabled - indicates that this detector is not used. working - indicates that this detector has no error. otherError - indicates an error not defined here. See Operator's manual. erraticCount - indicates that the vehicle count for this detector has exceeded the value of its rmcMergeErraticCount-object. maxPresence - indicates a continuous actuation for this detector that has exceeded the value of its rmcMergeMaxPresence-object. noActivity - indicates a continuous non-actuation for this detector that has exceeded the value of its rmcMergeNoActivity-object. errorAtSensor - indicates that the sensor for this detector has reported an error. See Operator's manual. 1.3.6.1.4.1.1206.4.2.2.3.2.4.1.2" REFERENCE "See Clause A.2.3.1" ::={ rmcDependGroupStatEntry 2 } rmcHistMergeStatus OBJECT-TYPE SYNTAX INTEGER (0..65535) -- BITMAP16 ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the cumulative status of the merge detector. Status values are indicated as follows: Bit Number Name Description Bit 15: reserved. Bit 14: reserved. Bit 13: reserved. Bit 12: reserved. Bit 11: reserved. Bit 10: reserved. Bit 09: reserved. Bit 08: reserved. Bit 07: reserved. Bit 06: Error at Sensor – the rmcMergeStatus-object has or had a value of ‘Disabled’ since reset. Bit 05: No activity – the rmcMergeStatus-object has or had a value of ‘noActivity’ since reset. Bit 04: Max presence – the rmcMergeStatus-object has or had a value of ‘maxPresence’ since reset. Bit 03: Erratic count – the rmcMergeStatus-object has or had a value of ‘erraticCount’ since reset. Bit 02: Other error – the rmcMergeStatus-object has or had a value of ‘otherError’ since reset. Bit 01: Working – the rmcMergeStatus-object has or had a value of ‘Working’ since reset. Bit 00: Disabled – the rmcMergeStatus-object has or had a value of ‘Disabled’ since reset. In the context of this object, ‘reset’ means either an initialization of the RMC or a successful SET of the rmcHistDetectorReset-object. When a ‘reset’ occurs, all bits shall be set to 0. All reserved bits shall always be set to zero (0). A bad value error shall be returned, if a management application writes a one (1) to any of the reserved bits. 1.3.6.1.4.1.1206.4.2.2.3.2.4.1.3" REFERENCE "See Clause A.2.3.1" ::={ rmcDependGroupStatEntry 3 } rmcMergeOverStat OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the rmcMergeFlag-object has or had a value of ‘True’ in the most recently completed calculation interval. 0 = false - indicates that the rmcMergeFlag-object does not have and did not have a value of ‘True’ in the most recently completed calculation interval. 1 = true - indicates that the rmcMergeFlag-object has or had a value of ‘True’ in the most recently completed calculation interval. 1.3.6.1.4.1.1206.4.2.2.3.2.4.1.4" REFERENCE "See Clause A.2.3.1" ::={ rmcDependGroupStatEntry 4 } rmcQueue OBJECT IDENTIFIER ::={ rmcMeter 3 } -- This node is an identifier used to group the objects for the configuration, -- control and status of the queue detectors parameters that are common to all -- ramp meter devices. rmcMaxNumQueueEntries OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the maximum number of queue detectors that can be stored in the Queue Detector Configuration and Control Table, and, by association, in the queue detector status tables. number 1.3.6.1.4.1.1206.4.2.2.3.3.1" REFERENCE "See Clause A.2.2.3" ::={ rmcQueue 1 } -- USERS TAKE NOTE OF MULTIPLE VERSIONS - -- the INTEGER range was changed to start at 1 instead of 0. This -- does not cause backwards compatibility problems because this object would -- not have been supported, if the function was not supported in the device. rmcNumQueueEntries OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the actual number of queue detectors that are present in the Queue Detector Configuration and Control Table, and, by association, in the queue detector status tables. This value shall not exceed the value of the rmcMaxNumQueueEntries-object. number 1.3.6.1.4.1.1206.4.2.2.3.3.2" REFERENCE "See Clause A.2.2.3" ::={ rmcQueue 2 } -- USERS TAKE NOTE OF MULTIPLE VERSIONS - -- the INTEGER range was changed to start at 1 instead of 0. This -- does not cause backwards compatibility problems because this object would -- not have been supported, if the function was not supported in the device. rmcQueueCtrlTable OBJECT-TYPE SYNTAX SEQUENCE OF RmcQueueCtrlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing the queue detectors that can be selected based on the metered lane number.
static 1.3.6.1.4.1.1206.4.2.2.3.3.3" ::={ rmcQueue 3 } rmcQueueCtrlEntry OBJECT-TYPE SYNTAX RmcQueueCtrlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Configuration and control parameters of the queue detector table. The entry with the lower index value will be considered the highest priority queue detector. A particular row of this table can be managed using the rmcQueueDetectMode- object. If that object has a value of 'disabled', the associated row is not used. 1.3.6.1.4.1.1206.4.2.2.3.3.3.1" INDEX { rmcMeterNumber, rmcQueueNum } ::={ rmcQueueCtrlTable 1 } RmcQueueCtrlEntry ::=SEQUENCE { rmcQueueNum INTEGER, rmcQueueType INTEGER, rmcQueueDetectMode INTEGER, rmcQueueLengthUpLimit INTEGER, rmcQueueLengthLowLimit INTEGER, rmcQueueOccUpLimit INTEGER, rmcQueueOccUpDelay INTEGER, rmcQueueOccLowLimit INTEGER, rmcQueueOccLowDelay INTEGER, rmcQueueQOccUpLimit INTEGER, rmcQueueQOccUpDelay INTEGER, rmcQueueQOccLowLimit INTEGER, rmcQueueQOccLowDelay INTEGER, rmcQueueAdjustMode INTEGER, rmcQueueAdjustRate INTEGER, rmcQueueAdjustRateLimit INTEGER, rmcQueueAdjustRateDelay INTEGER, rmcQueueAdjustRateIter INTEGER, rmcQueueAdjustLevel INTEGER, rmcQueueAdjustLevelLimit INTEGER, rmcQueueAdjustLevelDelay INTEGER, rmcQueueAdjustLevelIter INTEGER, rmcQueueReplaceRate INTEGER, rmcQueueErraticCount INTEGER, rmcQueueMaxPresence INTEGER, rmcQueueNoActivity INTEGER, rmcQueueDependMaxPresence INTEGER, -- added in version 2 rmcQueueDependNoActivity INTEGER -- added in version 2 } rmcQueueNum OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the secondary index into the table. The value of this object serves as a unique identifier for every queue detector, regardless of the value of the rmcQueueType-object, that is associated with the metered lane described in the primary key. The value of this secondary key object cannot exceed the value of the rmcMaxNumQueueEntries–object. 1.3.6.1.4.1.1206.4.2.2.3.3.3.1.1" REFERENCE "See Clause A.2.2.3" ::={ rmcQueueCtrlEntry 1 } rmcQueueType OBJECT-TYPE SYNTAX INTEGER { other (1), intermediate (2), excessive (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates whether the queue detector is an intermediate or excessive. The values are: other -other queue detector type than specified below. See Operator's Manual. intermediate - indicates that this detector is an intermediate queue detector. excessive - indicates that this detector is an excessive queue detector. 1.3.6.1.4.1.1206.4.2.2.3.3.3.1.2" REFERENCE "See Clause A.2.2.3 and A.9.2" ::={ rmcQueueCtrlEntry 2 } rmcQueueDetectMode OBJECT-TYPE SYNTAX INTEGER { disabled (1), count (2), occupancy (3), quickOccupancy (4) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the mode that is being used to determine the existence of a queue. The values are: disabled - no queue detection shall occur. count - the existence of a queue shall be determined using the difference between vehicle counts on the queue and passage detectors. ANNEX A describes in detail how a queue can be determined using 'counts'. occupancy - the existence of a queue shall be determined using the occupancy measured at the queue detector over the number of calculation intervals as specified in the rmcQueueOccUpDelay and rmcQueueOccLowDelay objects. ANNEX A describes in detail how an queue can be determined using 'occupancy'. quickOccupancy -- the existence of an queue shall be determined using the occupancy measured at the queue detector over the period of time as specified in the rmcQueueQOccUpDelay and rmcQueueQOccLowDelay objects. ANNEX A describes in detail how a queue can be determined using 'quickOccupancy'. 1.3.6.1.4.1.1206.4.2.2.3.3.3.1.3" REFERENCE "See Clause A.9.1" ::={ rmcQueueCtrlEntry 3 } rmcQueueLengthUpLimit OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the number of vehicles stored on the metered lane that, if exceeded, defines the existence of a queue if the rmcQueueDetectMode-object has a value of 'count'. This count is obtained by summing the differences between the vehicle counts at the passage and queue detectors over successive calculation intervals. This value shall be greater than or equal to the value of the rmcQueueLengthLowLimit-object. This value shall be expressed in 1-vehicle increments. A suggested usable range is 5 to 100. number 1.3.6.1.4.1.1206.4.2.2.3.3.3.1.4" REFERENCE "See Clause A.9.1" ::={ rmcQueueCtrlEntry 4 } rmcQueueLengthLowLimit OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the number of vehicles stored on the metered lane that, if not exceeded, defines the non-existence of a queue if the rmcQueueDetectMode- object has a value of 'count'. This count is obtained by summing the differences between the vehicle counts at the passage and queue detectors over successive calculation intervals intervals. This value shall be less than or equal to the value of the rmcQueueLengthUpLimit-object. This value shall be expressed in 1-vehicle increments. A suggested usable range is 5 to 100. number 1.3.6.1.4.1.1206.4.2.2.3.3.3.1.5" REFERENCE "See Clause A.9.1" ::={ rmcQueueCtrlEntry 5 } rmcQueueOccUpLimit OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the occupancy of a queue detector that, if exceeded, defines the existence of an queue when the rmcQueueDetectMode-object has a value of 'occupancy'. This value shall be greater than or equal to the value of the rmcQueueOccLowLimit-object. This value shall be expressed in 0.1-percent increments(i.e, 40 = 4.0 percent). A suggested usable range is 0 to 1000. tenth of percent 1.3.6.1.4.1.1206.4.2.2.3.3.3.1.6" REFERENCE "See Clause A.9.1" ::={ rmcQueueCtrlEntry 6 } rmcQueueOccUpDelay OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the number of calculation intervalsthat the occupancy of the queue detector shall exceed the value of the rmcQueueOccUpLimit-object to define the existence of a queue, if the rmcQueueDetectMode-object has a value of 'occupancy'. This value shall be greater than or equal to the value of the rmcQueueOccLowDelay-object. This value shall be expressed in 1-interval increments. A suggested usable range is 0 to 30. interval 1.3.6.1.4.1.1206.4.2.2.3.3.3.1.7" REFERENCE "See Clause A.9.1" ::={ rmcQueueCtrlEntry 7 } rmcQueueOccLowLimit OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the occupancy of a queue detector that, when not exceeded, defines the non-existence of a queue if the rmcQueueDetectMode-object has a value of 'occupancy'. This value shall be less than or equal to the value of the rmcQueueOccUpLimit-object. This value shall be expressed in 0.1-percent increments (i.e, 40 = 4.0 percent). A suggested usable range is 0 to 1000. tenth of percent 1.3.6.1.4.1.1206.4.2.2.3.3.3.1.8" REFERENCE "See Clause A.9.1" ::={ rmcQueueCtrlEntry 8 } rmcQueueOccLowDelay OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the number of calculation intervalsthat the occupancy of the queue detector does not exceed the value of the rmcQueueOccLowLimit-object to define the non-existence of a queue if the rmcQueueDetectMode-object has a value of 'occupancy'. This value shall be less than or equal to the value of the rmcQueueOccUpDelay-object. This value shall be expressed in 1-interval increments. A suggested usable range is 0 to 30. interval 1.3.6.1.4.1.1206.4.2.2.3.3.3.1.9" REFERENCE "See Clause A.9.1" ::={ rmcQueueCtrlEntry 9 } rmcQueueQOccUpLimit OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the occupancy of a queue detector that, if exceeded, defines the existence of an queue if the rmcQueueDetectMode-object has a value of 'quickOccupancy'. This value shall be greater than or equal to the value of the rmcQueueQOccLowLimit-object. This value shall be expressed in 0.1-percent increments (i.e, 40 = 4.0 percent). A suggested usable range is 0 to 1000. tenth of percent 1.3.6.1.4.1.1206.4.2.2.3.3.3.1.10" REFERENCE "See Clause A.9.1" ::={ rmcQueueCtrlEntry 10 } rmcQueueQOccUpDelay OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the length of time that the occupancy of the queue detector exceeds the value of the rmcQueueOccUpLimit-object to define the existence of a queue, if the rmcQueueDetectMode-object has a value of 'quickOccupancy'. This value shall be greater than or equal to the value of the rmcQueueQOccLowDelay-object. This value shall be expressed in 0.1-second increments (i.e, 40 = 4.0 seconds). A suggested usable range is 0 to 300. tenth of second 1.3.6.1.4.1.1206.4.2.2.3.3.3.1.11" REFERENCE "See Clause A.9.1" ::={ rmcQueueCtrlEntry 11 } rmcQueueQOccLowLimit OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the occupancy of a queue detector that, when not exceeded, defines the non-existence of a queue if the rmcQueueDetectMode-object has a value of 'quickOccupancy'. This value shall be less than or equal to the value of the rmcQueueQOccUpLimit-object. This value shall be expressed in 0.1-percent increments (i.e, 40 = 4.0 percent). A suggested usable range is 0 to 1000. tenth of percent 1.3.6.1.4.1.1206.4.2.2.3.3.3.1.12" REFERENCE "See Clause A.9.1" ::={ rmcQueueCtrlEntry 12 } rmcQueueQOccLowDelay OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the length of time that the occupancy of the queue detector does not exceed the value of the rmcQueueOccLowLimit-object to define the non- existence of a queue, if the rmcQueueDetectMode-object has a value of 'quickOccupancy'. This value shall be less than or equal to the value of the rmcQueueQOccUpDelay-object. This value shall be expressed in 0.1-second increments (i.e, 40 = 4.0 seconds). A suggested usable range is 0 to 300. tenth of second 1.3.6.1.4.1.1206.4.2.2.3.3.3.1.13" REFERENCE "See Clause A.9.1" ::={ rmcQueueCtrlEntry 13 } rmcQueueAdjustMode OBJECT-TYPE SYNTAX INTEGER { other (1), rate (2), level (3), fixed (4) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the process used to override the queue. The values are: other - other source of control than specified below. See Operator's manual; rate - the queue will be overridden by increasing the current metering rate. For details, see ANNEX A. level - the queue will be overriden by decreasing the current metering level. This mode shall only be usable while the rmcImplementAction-object has a value of 'trafficResponsive'. For details, see ANNEX A. fixed - the queue will be overriden by replacing the current metering rate with the rate indicated in the rmcQueueReplaceRate-object. For details, see ANNEX A. 1.3.6.1.4.1.1206.4.2.2.3.3.3.1.14" REFERENCE "See Clause A.9.2" ::={ rmcQueueCtrlEntry 14 } rmcQueueAdjustRate OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the rate by which the current metering rate will be increased if a queue has been detected AND the rmcQueueAdjustMode-object has a value of 'rate'. This value shall be expressed in 1-vph increments. A suggested usable range is 0, 5 to 1800. A value of zero (0) indicates that no adjustments are made to the current metering rate. vehicles per hour 1.3.6.1.4.1.1206.4.2.2.3.3.3.1.15" REFERENCE "See Clause A.9.2" ::={ rmcQueueCtrlEntry 15 } rmcQueueAdjustRateLimit OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the highest metering rate at which the metered lane will be metered if a queue has been detected AND the rmcQueueAdjustMode-object has a value of 'rate'. This value shall be expressed in 1-vehicle increments. A suggested usable range is 0, 120 to 1800. A value of zero (0) indicates this parameter shall not be used. number 1.3.6.1.4.1.1206.4.2.2.3.3.3.1.16" REFERENCE "See Clause A.9.2" ::={ rmcQueueCtrlEntry 16 } rmcQueueAdjustRateDelay OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the length of time between successive queue override rate adjustments. This value shall be expressed in 1-second increments. A suggested usable range is 20 to 240. second 1.3.6.1.4.1.1206.4.2.2.3.3.3.1.17" REFERENCE "See Clause A.9.2" ::={ rmcQueueCtrlEntry 17 } rmcQueueAdjustRateIter OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the maximum number of queue override rate adjustments which can be made during the existence of a single queue. A suggested usable range is either - 0, or - 1 to 20 iterations in 1-iteration increments for queue detectors whose rmcQueueType-object has a value of 'intermediate', or - 1 iteration for queue detectors whose rmcQueueType-object has a value of 'excessive'. A value of zero (0) indicates that the current metering rate is not increased after a queue has been detected. 1.3.6.1.4.1.1206.4.2.2.3.3.3.1.18" REFERENCE "See Clause A.9.2" ::={ rmcQueueCtrlEntry 18 } rmcQueueAdjustLevel OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the number of levels by which the current metering level will be decreased if a queue has been detected AND the rmcQueueAdjustMode-object has a value of 'level'. This value shall be expressed in 1-level increments. A suggested usable range is 0, 1 to 5. A value of zero (0) indicates that no adjustments are made to the current metering level. number 1.3.6.1.4.1.1206.4.2.2.3.3.3.1.19" REFERENCE "See Clause A.9.2" ::={ rmcQueueCtrlEntry 19 } rmcQueueAdjustLevelLimit OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the lowest metering level at which the metered lane shall be metered if a queue has been detected AND the rmcQueueAdjustMode-object has a value of 'level'. This value shall be expressed in 1-level increments. A suggested usable range is 0, 1 to 5. A value of zero (0) indicates this parameter shall not be used. number 1.3.6.1.4.1.1206.4.2.2.3.3.3.1.20" REFERENCE "See Clause A.9.2" ::={ rmcQueueCtrlEntry 20 } rmcQueueAdjustLevelDelay OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the length of time between successive queue override level adjustments. This value shall be expressed in 1-second increments. A suggested usable range is 20 to 240. second 1.3.6.1.4.1.1206.4.2.2.3.3.3.1.21" REFERENCE "See Clause A.9.2" ::={ rmcQueueCtrlEntry 21 } rmcQueueAdjustLevelIter OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the maximum number of queue override level adjustments which can be made during the existence of a single queue. A suggested usable range is either - 0, or - 1 to 5 iterations in 1-iteration increments for queue detectors whose rmcQueueType-object has a value of 'intermediate', or - 1 iteration for queue detectors whose rmcQueueType-object has a value of 'excessive'. A value of zero (0) indicates that the current metering level is not decreased after a queue has been detected. 1.3.6.1.4.1.1206.4.2.2.3.3.3.1.22" REFERENCE "See Clause A.9.2" ::={ rmcQueueCtrlEntry 22 } rmcQueueReplaceRate OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the metering rate at which the metered lane will be metered if a queue has been detected AND the rmcQueueAdjustMode-object has a value of 'fixed'. This value shall be expressed in 1-vehicle increments. A suggested usable range is 0, 600 to 1800. A value of zero (0) indicates that no adjustments to the metering rate are made when the rmcQueueAdjustMode-object has a value of 'fixed'. number 1.3.6.1.4.1.1206.4.2.2.3.3.3.1.23" REFERENCE "See Clause A.9.2" ::={ rmcQueueCtrlEntry 23 } rmcQueueErraticCount OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "If the vehicle count, over the most recently completed calculation interval, on a queue detector exceeds this threshold, the rmcQueueStatus-object for that detector shall be set to 'erraticCount'. This value shall be expressed in 1-vehicle increments. A suggested usable range is 0, 2 to 10. A value of zero (0) shall inhibit the erratic count testing on this queue detector. number 1.3.6.1.4.1.1206.4.2.2.3.3.3.1.24" REFERENCE "See Clause A.2.2.3" ::={ rmcQueueCtrlEntry 24 } rmcQueueMaxPresence OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "If the input on a queue detector has been continuously actuated for longer than the time indicated by this threshold, the rmcQueueStatus-object shall be set to 'maxPresence' for that detector. This value shall be expressed in 1-minute increments. A suggested usable range is 0 to 1500. A value of zero (0) shall inhibit the maximum presence testing on this queue detector. minute 1.3.6.1.4.1.1206.4.2.2.3.3.3.1.25" REFERENCE "See Clause A.2.2.3" ::={ rmcQueueCtrlEntry 25 } rmcQueueNoActivity OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "If the input on a queue detector has not been actuated for longer than the time indicated by this threshold, the rmcQueueStatus-object shall be set to 'noActivity' for that detector. This value shall be expressed in 1-minute increments. A suggested usable range is 0 to 1500. A value of zero (0) shall inhibit the no activity testing on this queue detector. minute 1.3.6.1.4.1.1206.4.2.2.3.3.3.1.26" REFERENCE "See Clause A.2.2.3" ::={ rmcQueueCtrlEntry 26 } rmcQueueDependMaxPresence OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "If the input on the queue detector for a metered lane has been continuously actuated, while the input on the passage detector for the same metered lane has been continuously non-actuated for longer than the time indicated by this threshold and the rmcPassageMode-object is not ‘recalled’ and the rmcPassageStatus-object is ‘working’, the rmcQueueStatus-object for that metered lane shall be set to a value of 'depMaxPresence'. This value shall be expressed in 1-second increments. A suggested usable range is 0 to 600. A value of zero (0) shall inhibit the dependent maximum presence testing. second 1.3.6.1.4.1.1206.4.2.2.3.3.3.1.27" REFERENCE "See Clause A.2.2.3" ::={ rmcQueueCtrlEntry 27 } rmcQueueDependNoActivity OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "If the input on the queue detector for a metered lane has not been actuated, while more vehicles than indicated by this threshold have been counted on the passage detector of the same metered lane and the rmcPassageMode-object is not ‘recalled’ and the rmcPassageStatus-object is ‘working’, the rmcQueueStstus-object for that metered lane shall be set to a value of 'depNoActivity'. This value shall be expressed in 1-vehicle increments. A suggested usable range is 0 to 30. A value of zero (0) shall inhibit the dependent no activity testing. number 1.3.6.1.4.1.1206.4.2.2.3.3.3.1.28" REFERENCE "See Clause A.2.2.3" ::={ rmcQueueCtrlEntry 28 } rmcQueueStatTable OBJECT-TYPE SYNTAX SEQUENCE OF RmcQueueStatEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing the status information for queue detectors.
static 1.3.6.1.4.1.1206.4.2.2.3.3.3.10" ::={ rmcQueue 10 } --Editor’s Note: There is a skip in OID at this point, but this was already in --version 1 and I cannot change the OID in version 2 for any existing object. rmcQueueStatEntry OBJECT-TYPE SYNTAX RmcQueueStatEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Status parameters of the queue detector table. The entry with the lower index value will be considered the higher priority queue detector. This table is directly correlated to the Queue Detector Configuration and Control Table, which means that the number of rows in this table is exactly the same as the number of rows in the Queue Detector Configuration and Control Table (AUGMENT TABLE in SNMPv2 terminology). Table management can only take place through the Queue Detector Configuration and Control Table, while this table provides status information for the associated queue detector. 1.3.6.1.4.1.1206.4.2.2.3.3.3.10.1" INDEX { rmcMeterNumber, rmcQueueNum } ::={ rmcQueueStatTable 1 } RmcQueueStatEntry ::=SEQUENCE { rmcQueueFlag INTEGER, rmcQueueStatus INTEGER, rmcHistQueueStatus INTEGER –- added in version 2 } rmcQueueFlag OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether a queue has been detected 0 = false - indicates that no queue has been detected. 1 = true - indicates that a queue has been detected. 1.3.6.1.4.1.1206.4.2.2.3.3.3.10.1.1" REFERENCE "See Clause A.6, A.8.3.1.2, A.8.4.1, A.8.5.3.5, A.9.1 and A.9.2" ::={ rmcQueueStatEntry 1 } rmcQueueStatus OBJECT-TYPE SYNTAX INTEGER { disabled (1), working (2), otherError (3), erraticCount (4), maxPresence (5), noActitity (6), errorAtSensor (7), noDepActivity (8), -- added in version 2 maxDepPresence (9) -- added in version 2 } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the status of the queue detector. The values are: disabled - indicates that this detector is not used. working - indicates that this detector has no error. otherError - indicates an error not defined here. See Operator's manual; erraticCount - indicates that the vehicle count for this detector has exceeded the value of its rmcQueueErraticCount-object; maxPresence - indicates that a continuous actuation for this detector has exceeded the value of its rmcQueueMaxPresence-object; noActivity - indicates that a continuous non-actuation for this detector has exceeded the value of its rmcQueueNoActivity-object; errorAtSensor - indicates that the sensor for this detector has reported an error. See Operator's manual. depNoActivity - indicates a continuous non-actuation for this detector, while a count of vehicles on the passage detector in the same metered lane that has exceeded the value of its rmcQueueDepNoActivity-object. depMaxPresence - indicates a continuous actuation for this detector, while a continuous non-actuation of the passage detector in the same metered lane that has exceeded the value of its rmcQueueDepMaxPresence-object. 1.3.6.1.4.1.1206.4.2.2.3.3.3.10.1.2" REFERENCE "See Clause A.2.2.3" ::={ rmcQueueStatEntry 2 } rmcHistQueueStatus OBJECT-TYPE SYNTAX INTEGER (0..65535) -- BITMAP16 ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the cumulative status of the queue detector. The values are: Bit Number Name Description Bit 15: reserved. Bit 14: reserved. Bit 13: reserved. Bit 12: reserved. Bit 11: reserved. Bit 10: reserved. Bit 09: reserved. Bit 08: Dependent Max Presence – the rmcQueueStatus-object has or had a value of ‘depNoActivity’ since reset. Bit 07: Dependent No Activity – the rmcQueueStatus-object has or had a value of ‘depNoActivity’ since reset. Bit 06: Error At Sensor – the rmcQueueStatus-object has or had a value of ‘Disabled’ since reset. Bit 05: No Activity – the rmcQueueStatus-object has or had a value of ‘noActivity’ since reset. Bit 04: Max Presence – the rmcQueueStatus-object has or had a value of ‘maxPresence’ since reset. Bit 03: Erratic Count – the rmcQueueStatus-object has or had a value of ‘erraticCount’ since reset. Bit 02: Other Error – the rmcQueueStatus-object has or had a value of ‘otherError’ since reset. Bit 01: Working – the rmcQueueStatus-object has or had a value of ‘Working’ since reset. Bit 00: Disabled – the rmcQueueStatus-object has or had a value of ‘Disabled’ since reset. In the context of this object, ‘reset’ means either an initialization of the RMC or a successful SET of the rmcHistDetectorReset-object. When a ‘reset’ occurs, all bits shall be set to 0. All reserved bits shall always be set to zero (0). A bad value error shall be returned, if a management application writes a one (1) to any of the reserved bits. 1.3.6.1.4.1.1206.4.2.2.3.3.3.10.1.3" REFERENCE "See Clause A.2.2.3" ::={ rmcQueueStatEntry 3 } rmcPassage OBJECT IDENTIFIER ::= { rmcMeter 5 } -- This node is an identifier used to group the objects for the configuration, -- control and status of the passage detectors parameters that are common to -- all ramp meter control units. rmcPassageCtrlTable OBJECT-TYPE SYNTAX SEQUENCE OF RmcPassageCtrlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing the configuration and control information for a passage detector.
static 1.3.6.1.4.1.1206.4.2.2.3.5.1" ::={ rmcPassage 1 } rmcPassageCtrlEntry OBJECT-TYPE SYNTAX RmcPassageCtrlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Configuration and control parameters of the passage detector table. The number of rows within this table shall be the same as within the Metered Lane Configuration Table. If this table is supported, there shall be a passage detector for each metered lane. The rows within this table cannot be managed following the same principles applied to other tables. It is anticipated that, if passage detectors are utilized within an implementation, each metered lane will have one passage detector. However, not every metered lane might have a physical passage detector and shall therefore be set into 'recalled' using the rmcPassageMode- object to utilize the passage detection functionality. 1.3.6.1.4.1.1206.4.2.2.3.5.1.1" INDEX { rmcMeterNumber } ::={ rmcPassageCtrlTable 1 } RmcPassageCtrlEntry ::=SEQUENCE { rmcPassageMode INTEGER, rmcPassageErraticCount INTEGER, rmcPassageMaxPresence INTEGER, rmcPassageNoActivity INTEGER, rmcPassageDependNoActivity INTEGER –- added in version 2 } rmcPassageMode OBJECT-TYPE SYNTAX INTEGER { recalled (1), enabledCall (2), enabledNoCall (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the mode of the passage detector. The values are: recalled - indicates that the passage detector shall constantly place a call, even without a vehicle being present in its detection zone. enabledCall - indicates that the passage detector is ready to detect, and shall constantly place a call when it has failed. enabledNoCall - indicates that the passage detector is ready to detect, and shall NOT place a call when it has failed. 1.3.6.1.4.1.1206.4.2.2.3.5.1.1.1" REFERENCE "See Clause A.2.2.2" ::={ rmcPassageCtrlEntry 1 } rmcPassageErraticCount OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "If the vehicle count, over the most recently completed calculation interval, on the passage detector for this metered lane exceeds this threshold, the rmcPassageStatus-object shall be set to a value of 'erraticCount'. This value shall be expressed in 1-vehicle increments. A suggested usable range is 0, 5 to 10. A value of zero (0) shall inhibit the erratic count testing. number 1.3.6.1.4.1.1206.4.2.2.3.5.1.1.2" REFERENCE "See Clause A.2.2.2" ::={ rmcPassageCtrlEntry 2 } rmcPassageMaxPresence OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "If the input on the passage detector for this metered lane has been continuously actuated for longer than the time indicated by this threshold, the rmcPassageStatus-object shall be set to a value of 'maxPresence'. This value shall be expressed in 1-minute increments. A suggested usable range is 0 to 1500. A value of zero (0) shall inhibit the maximum presence testing. minute 1.3.6.1.4.1.1206.4.2.2.3.5.1.1.3" REFERENCE "See Clause A.2.2.2" ::={ rmcPassageCtrlEntry 3 } rmcPassageNoActivity OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "If the input on the passage detector for this metered lane has not been actuated for longer than the time indicated by this threshold, the rmcPassageStatus-object shall be set to a value of 'noActivity'. This value shall be expressed in 1-minute increments. A suggested usable range is 0 to 1500. A value of zero (0) shall inhibit the no activity testing. minute 1.3.6.1.4.1.1206.4.2.2.3.5.1.1.4" REFERENCE "See Clause A.2.2.2" ::={ rmcPassageCtrlEntry 4 } rmcPassageDependNoActivity OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "If the input on the passage detector for a metered lane has not been actuated, while more vehicles than indicated by this threshold have been counted on the demand detector of the same metered lane and the rmcDemandMode- object is not ‘recalled’ and the rmcDemandStatus is ‘working’, the rmcPassageErrorStstus-object for that metered lane shall be set to a value of 'depNoActivity'. This value shall be expressed in 1-vehicle increments. A suggested usable range is 0 to 30. A value of zero (0) shall inhibit the dependent no activity testing. number 1.3.6.1.4.1.1206.4.2.2.3.5.1.1.5" REFERENCE "See Clause A.2.2.2" ::={ rmcPassageCtrlEntry 5 } rmcPassageStatTable OBJECT-TYPE SYNTAX SEQUENCE OF RmcPassageStatEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing the status information for a passage detector.
static 1.3.6.1.4.1.1206.4.2.2.3.5.2" ::={ rmcPassage 2 } rmcPassageStatEntry OBJECT-TYPE SYNTAX RmcPassageStatEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Status parameters of the passage detector table. This table is directly correlated to the Passage Detector Configuration and Control Table, which means that the number of rows in this table is exactly the same as the number of rows in the Passage Detector Configuration and Control Table (AUGMENT TABLE in SNMPv2 terminology). Table management can only take place through the PassagDetector Configuration and Control Table, while this table provides status information for the associated passage detector. 1.3.6.1.4.1.1206.4.2.2.3.5.2.1" INDEX { rmcMeterNumber } ::={ rmcPassageStatTable 1 } RmcPassageStatEntry ::=SEQUENCE { rmcPassageStatus INTEGER, rmcHistPassageStatus INTEGER, -- added in version 2 rmcPassageVehicleCount INTEGER, -- added in version 2 rmcRedViolationCount INTEGER -- added in version 2 } rmcPassageStatus OBJECT-TYPE SYNTAX INTEGER { recalled (1), working (2), otherError (3), erraticCount (4), maxPresence (5), noActivity (6), -- spelling was corrected in version 2 errorAtSensor (7), depNoActivity (8) -- added in version 2 } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the status of the passage detector. The values are: recalled - indicates that the value of the rmcPassageMode-object is 'recalled'. working - that this detector has no error. otherError - indicates an error not defined here. See Operator's manual. erraticCount - indicates that the vehicle count for this detector has exceeded the value of its rmcPassageErraticCount-object. maxPresence - indicates a continuous actuation for this detector that has exceeded the value of its rmcPassageMaxPresence-object. noActivity - indicates a continuous non-actuation for this detector that has exceeded the value of its rmcPassageNoActivity-object. errorAtSensor - indicates that the sensor for this detector has reported an error. See Operator's manual. depNoActivity - indicates a continuous non-actuation for this detector, while a count of vehicles on the demand detector in the same metered lane that has exceeded the value of its rmcPassageDependNoActivity-object. 1.3.6.1.4.1.1206.4.2.2.3.5.2.1.1" REFERENCE "See Clause A.2.2.2" ::={ rmcPassageStatEntry 1 } rmcHistPassageStatus OBJECT-TYPE SYNTAX INTEGER (0..65535) -- BITMAP16 ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the cumulative status of the passage detector. The values are: Bit Number Name Description Bit 15: reserved Bit 14: reserved Bit 13: reserved Bit 12: reserved Bit 11: reserved Bit 10: reserved Bit 09: reserved Bit 08: reserved Bit 07: Dependent No activity – the rmcPassageStatus-object has or had a value of ‘depNoActivity’ since reset. Bit 06: Error at Sensor – the rmcPassageStatus-object has or had a value of ‘ErrorAtSensor’ since reset. Bit 05: No activity – the rmcPassageStatus-object has or had a value of ‘noActivity’ since reset. Bit 04: Max presence – the rmcPassageStatus-object has or had a value of ‘maxPresence’ since reset. Bit 03: Erratic count – the rmcPassageStatus-object has or had a value of ‘erraticCount’ since reset. Bit 02: Other error – the rmcPassageStatus-object has or had a value of ‘otherError’ since reset. Bit 01: Working – the rmcPassageStatus-object has or had a value of ‘Working’ since reset. Bit 00: Disabled – the rmcPassageStatus-object has or had a value of ‘Disabled’ since reset. In the context of this object, ‘reset’ means either an initialization of the RMC or a successful SET of the rmcHistDetectorReset-object. When a ‘reset’ occurs, all bits shall be set to 0. All reserved bits shall always be set to zero (0). A bad value error shall be returned, if a management application writes a one (1) to any of the reserved bits. 1.3.6.1.4.1.1206.4.2.2.3.5.2.1.2" REFERENCE "See Clause A.2.2.2" ::={ rmcPassageStatEntry 2 } rmcPassageVehicleCount OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the number of actuations of the passage detector in the most recently completed calculation interval. number 1.3.6.1.4.1.1206.4.2.2.3.5.2.1.3" REFERENCE "See Clause A.2.2.2" ::={ rmcPassageStatEntry 3 } 3.4.4.2.4.1 rmcRedViolationCount OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the number of violations detected during the red time in the most recently completed calculation interval. number 1.3.6.1.4.1.1206.4.2.2.3.5.2.1.4" REFERENCE "See Clause A.2.2.2" ::={ rmcPassageStatEntry 4 } rmcHistDetectorReset OBJECT-TYPE SYNTAX INTEGER (0.. 4294967295) ACCESS read-write STATUS mandatory DESCRIPTION "Provides a means to reset all of the Historic Detector Status objects that are used for the various types of detectors, if present. A SET (write) of this object shall reset the referenced objects. A GET (read) of this object shall return the value of ‘globalTime’ to indicate the time at which the last reset of the historical error status objects occurred. If this object is set, the value of the following objects shall be set to ‘0’: - rmcMLHistLeadStatus-object, - rmcMLHistTrailStatus-object, - rmcHistDemandStatus-object, - rmcHistMergeStatus-object, - rmcHistQueueStatus-object, - rmcHistPassageStatus-object 1.3.6.1.4.1.1206.4.2.2.3.2.4.1.6" REFERENCE "See Clause A.2.3.1" ::={ rmcMeter 6 } meteringPlan OBJECT IDENTIFIER ::={ ramp 4 } -- This node is an identifier used to group all objects for the configuration -- of the metering plans that are common to all ramp meter control units. -- Each defined metering plan can be used with any metered lane by association -- within the rmcMeterCtrlTable. rmcMaxNumMeteringPlans OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the maximum number of metering plans that can be stored in the Metering Plan Table. A suggested minimum number of plans is four (4). number 1.3.6.1.4.1.1206.4.2.2.4.1" REFERENCE "See Clause A.7.1" ::={ meteringPlan 1 } rmcNumMeteringPlans OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the actual number of metering plans that are present in the Metering Plan Table. This value shall not exceed the value of the rmcMaxNumMeteringPlans-object. number 1.3.6.1.4.1.1206.4.2.2.4.2" REFERENCE "See Clause A.7.1" ::={ meteringPlan 2 } rmcMaxNumLevelsPerPlan OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the maximum number of metering levels that can be stored in EACH metering plan. A suggested minimum number of levels per metering plan is three (3). number 1.3.6.1.4.1.1206.4.2.2.4.3" REFERENCE "See Clause A.7.1" ::={ meteringPlan 3 } rmcNumMeteringLevels OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS deprecated DESCRIPTION "Indicates the actual number of levels that are present in the ENTIRE metering plan table. This value shall not exceed the product of the value of the rmcMaxNumLevelsPerPlan–object times the value of the rmcMaxNumMeteringPlans object. number 1.3.6.1.4.1.1206.4.2.2.4.4" REFERENCE "See Clause A.7.1" ::={ meteringPlan 4 } -- USERS TAKE NOTE OF MULTIPLE VERSIONS - this object was deprecated in -- version 02. The reason is that this object does no longer provide any -- useful functionality. This is due to the fact that the following table -- description was updated to follow the requirements of NTCIP 8004v2. No -- backwards compatibility issues are expected because this was a -- status/reporting object. rmcMeteringPlanTable OBJECT-TYPE SYNTAX SEQUENCE OF RmcMeteringPlanEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing the configuration information for a metering level entry in a metering plan.
static 1.3.6.1.4.1.1206.4.2.2.4.5" ::={ meteringPlan 5 } rmcMeteringPlanEntry OBJECT-TYPE SYNTAX RmcMeteringPlanEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Configuration parameters of the metering plan table. A particular row of this table can be managed using the rmcMeteringRate-object. A level within a metering plan is unused when the value of the rmcMeteringRate-object has been set to '0'. The entries in this table are intended for use by every metered lane, if the associated command action is 'trafficResponsive'. The associated rmcXxxxPlan- object (Xxxx is a placeholder for all mentioned possible metering plans) will point to a particular metering plan number. 1.3.6.1.4.1.1206.4.2.2.4.5.1" INDEX { rmcMeteringPlanNumber, rmcMeteringLevel } ::={ rmcMeteringPlanTable 1 } RmcMeteringPlanEntry ::=SEQUENCE { rmcMeteringPlanNumber INTEGER, rmcMeteringLevel INTEGER, rmcMeteringRate INTEGER, rmcFlowRateThreshold INTEGER, rmcOccupancyThreshold INTEGER, rmcSpeedThreshold INTEGER } rmcMeteringPlanNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "Primary key into this table defining an enumerated listing of row entries that indicate the number of metering plans stored for this RMC unit. This value shall not exceed the value of the rmcMaxNumMeteringPlans–object. This is the object pointed to by all rmcXxxxPlan-objects. number 1.3.6.1.4.1.1206.4.2.2.4.5.1.1" REFERENCE "See Clause A.7.1" ::={ rmcMeteringPlanEntry 1 } rmcMeteringLevel OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "Secondary key into this table defining an enumerated listing of row entries that indicate the number of metering levels stored for this RMC unit and the associated metering plan. This value shall not exceed the value of the rmcMaxNumLevelsPerPlan-object. number 1.3.6.1.4.1.1206.4.2.2.4.5.1.2" REFERENCE "See Clause A.7.1" ::={ rmcMeteringPlanEntry 2 } -- USERS TAKE NOTE OF MULTIPLE VERSIONS - -- the INTEGER range was changed to start at 1 instead of 0. This -- does not cause backwards compatibility problems because this object would -- not have been supported, if the function was not supported in the device. -- Additionally, an index field of an SNMP table cannot have a value of ‘0’. rmcMeteringRate OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the metering rate which corresponds to this metering level. A suggested usable range is 0, 120 to 1800 in 1-vph increments. A value of zero (0) indicates that the ENTIRE level shall not be used during traffic responsive metering, including queue override adjustment. vehicles per hour 1.3.6.1.4.1.1206.4.2.2.4.5.1.3" REFERENCE "See Clause A.7.1" ::={ rmcMeteringPlanEntry 3 } rmcFlowRateThreshold OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the average flow rate threshold, which corresponds to this metering plan and level. This value shall be expressed in 1-vph increments. A suggested usable range is 0, 1000 to 3600. A value of zero (0) indicates that this threshold shall NOT be used with flow rate during traffic responsive metering. vehicles per hour 1.3.6.1.4.1.1206.4.2.2.4.5.1.4" REFERENCE "See Clause A.7.1" ::={ rmcMeteringPlanEntry 4 } rmcOccupancyThreshold OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the average occupancy threshold, which corresponds to this metering plan and level. This value shall be expressed in 0.1-percent increments (i.e, 40 = 4.0 percent). A suggested usable range is 0 and 50 to 300. A value of zero (0) indicates that this threshold shall NOT be used with occupancy during traffic responsive metering. tenth of percent 1.3.6.1.4.1.1206.4.2.2.4.5.1.5" REFERENCE "See Clause A.7.1" ::={ rmcMeteringPlanEntry 5 } rmcSpeedThreshold OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the average speed threshold, which corresponds to this metering plan and level. This value shall be expressed in 1-km/h increments. A suggested usable range is 0, 15 to 100. A value of zero (0) indicates that this threshold shall NOT be used with speed during traffic responsive metering. kilometer per hour 1.3.6.1.4.1.1206.4.2.2.4.5.1.6" REFERENCE "See Clause A.7.1" ::={ rmcMeteringPlanEntry 6 } rmcTimebase OBJECT IDENTIFIER ::={ ramp 5 } -- This node is an identifier used to group all ramp meter control control -- unit-specific objects supporting timebased scheduling. rmcMaxNumTBCActions OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the maximum number of timebase control actions that can be stored in the (Timebase Control) Action Table. number 1.3.6.1.4.1.1206.4.2.2.5.1" REFERENCE "See Clause A.3.1" ::={ rmcTimebase 1 } -- USERS TAKE NOTE OF MULTIPLE VERSIONS - -- the INTEGER range was changed to start at 1 instead of 0. This -- does not cause backwards compatibility problems because this object would -- not have been supported, if the function was not supported in the device. rmcNumTBCActions OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the actual number of timebase control actions that are present in the (Timebase Control) Action Table. This value shall not exceed the value of the rmcMaxNumTBCActions-object. number 1.3.6.1.4.1.1206.4.2.2.5.2" REFERENCE "See Clause A.3.1" ::={ rmcTimebase 2 } -- USERS TAKE NOTE OF MULTIPLE VERSIONS - -- the INTEGER range was changed to start at 1 instead of 0. This -- does not cause backwards compatibility problems because this object would -- not have been supported, if the function was not supported in the device. rmcActionTable OBJECT-TYPE SYNTAX SEQUENCE OF RmcActionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing the actions that can be selected based on a time based scheduler. The scheduler will determine when an action shall be selected. The dayPlanTable of the scheduler (see Global Object Definitions) points to a row in this table to identify the action to be activated.
static 1.3.6.1.4.1.1206.4.2.2.5.3" REFERENCE "NTCIP 1201, timebase-node" ::={ rmcTimebase 3 } rmcActionEntry OBJECT-TYPE SYNTAX RmcActionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Parameters of the Timebase Control Action Table. A particular row of this table can be managed using the rmcActionMode-object. An action described within a row is unused when the value of that object has been set to zero (0). 1.3.6.1.4.1.1206.4.2.2.5.3.1" INDEX { rmcActionNum } ::={ rmcActionTable 1 } RmcActionEntry ::=SEQUENCE { rmcActionNum INTEGER, rmcActionMode INTEGER, rmcMeterActionNum INTEGER, rmcMLActionNum INTEGER } rmcActionNum OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "Enumerated listing of row entries. The value of this object cannot exceed the value of the rmcMaxNumTBCActions-object. This is the object to which the dayPlanAction-object within the Global Object Definitions points. number 1.3.6.1.4.1.1206.4.2.2.5.3.1.1" REFERENCE "See Clause A.3.1" ::={ rmcActionEntry 1 } rmcActionMode OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates whether this row is used. 0 = false - this row is NOT used. 1 = true - this row is used. 1.3.6.1.4.1.1206.4.2.2.5.3.1.2" ::={ rmcActionEntry 2 } rmcMeterActionNum OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to point to a value of the rmcMeterActionIndex-object. A value of zero (0) indicates that there are no Metered Lane action items associated with this Action Index. This value shall not exceed the value of the rmcNumMeterTBCActions-object. number 1.3.6.1.4.1.1206.4.2.2.5.3.1.3" ::={ rmcActionEntry 3 } rmcMLActionNum OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to point to a value of the rmcMLActionIndex-object. A value of zero (0) indicates that there are no Mainline Lane action items associated with this Action Index. This value shall not exceed the value of the rmcNumMLTBCActions-object. number 1.3.6.1.4.1.1206.4.2.2.5.3.1.4" ::={ rmcActionEntry 4 } rmcMaxNumMeterTBCActions OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the maximum number of metered lane timebase control actions that can be stored in the Metered Lane Timebase Control Action table. number 1.3.6.1.4.1.1206.4.2.2.5.4" REFERENCE "See Clause A.3.1" ::={ rmcTimebase 4 } -- USERS TAKE NOTE OF MULTIPLE VERSIONS - -- the INTEGER range was changed to start at 1 instead of 0. This -- does not cause backwards compatibility problems because this object would -- not have been supported, if the function was not supported in the device. rmcNumMeterTBCActions OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the actual number of metered lane timebase control actions that are present in this Metered Lane Timebase Control Action table. This value shall not exceed the value of the rmcMaxNumMeterTBCActions-object. number 1.3.6.1.4.1.1206.4.2.2.5.5" REFERENCE "See Clause A.3.1" ::={ rmcTimebase 5 } -- USERS TAKE NOTE OF MULTIPLE VERSIONS - -- the INTEGER range was changed to start at 1 instead of 0. This -- does not cause backwards compatibility problems because this object would -- not have been supported, if the function was not supported in the device. rmcMeterActionTable OBJECT-TYPE SYNTAX SEQUENCE OF RmcMeterActionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing the metered lane actions that can be selected based on a time-based scheduler. The rows within this table are pointed to by the rmcMeterActionNum-object within the rmcActionTable. This table is double-indexed describing what action to execute for which metered lane.
static 1.3.6.1.4.1.1206.4.2.2.5.6" ::={ rmcTimebase 6 } rmcMeterActionEntry OBJECT-TYPE SYNTAX RmcMeterActionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Parameters of the Timebase Control Action Table for a metered lane. A particular row of this table can be managed using the rmcMeterActionMode- object. An action described within a row is unused when the value of that object has been set to zero (0). 1.3.6.1.4.1.1206.4.2.2.5.6.1" INDEX { rmcMeterActionIndex, rmcMeterNumber } ::={ rmcMeterActionTable 1 } RmcMeterActionEntry ::=SEQUENCE { rmcMeterActionIndex INTEGER, rmcMeterActionMode INTEGER, rmcTBActionCtrl INTEGER, rmcTBPlanCtrl INTEGER, rmcTBRateCtrl INTEGER, rmcTBVehiclesPerGrnCtrl INTEGER, rmcTBCMinMeterRateCtrl INTEGER, rmcTBCMaxMeterRateCtrl INTEGER } rmcMeterActionIndex OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "Primary index to this double indexed table showing an enumerated listing of row entries. The value of the rmcMeterActionNum-object is pointing to THIS object,not to a particular row. All rows that are associated with this primary key will be activated if the scheduler points to the appropriate row within the rmcActionTable. The value of this object shall not exceed the value of the rmcMaxNumMeterTBCActions–object nor that of the rmcNumMeterTBCActions– object. number 1.3.6.1.4.1.1206.4.2.2.5.6.1.1" ::={ rmcMeterActionEntry 1 } rmcMeterActionMode OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates whether this row is used. 0 = false - this row is NOT being used. 1 = true - this row is used. 1.3.6.1.4.1.1206.4.2.2.5.6.1.2" ::={ rmcMeterActionEntry 2 } rmcTBActionCtrl OBJECT-TYPE SYNTAX INTEGER { dark (1), restInGreen (2), fixedRate (3), trafficResponsive (4), emergencyGreen (5), skip (6) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the action that may be active if the metered lane is controlled by timebase control. This object is used to control the entry, while the rmcTBActionStatus-object indicates the status. The values are: dark - indicates that the metered lane will advance to the Pre-Metering Non-Green interval. restInGreen - indicates that the metered lane will advance to the Pre-Metering Green interval. fixedRate - indicates that the metered lane will operate using the value of the rmcTBRateCtrl-object. trafficResponsive -indicates that the metered lane will operate using mainline station traffic conditions and the value of the rmcTBPlanCtrl-object. emergencyGreen - indicates that the metered lane will advance to the Post-metering Green interval without entering the Shutdown Green, Shutdown Yellow, Shutdown Red or Shutdown Warning intervals when the metered lane is NOT in the Non-metering state. The metered lane will advance to the Pre-Metering Green interval when the metered lane is in the Non-metering state. skip - indicates that the next-lower level command source shall be considered as specified by the rmcCmdSourcePriorityOrder-object. 1.3.6.1.4.1.1206.4.2.2.5.6.1.3" REFERENCE "See Clause A.3.1" ::={ rmcMeterActionEntry 3 } rmcTBPlanCtrl OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the metering plan number that to be used if the metered lane is commanded by timebase control and the rmcImplementAction-object has a value of 'trafficResponsive'. This value shall not exceed the value of the rmcMaxNumMeterPlans-object. This object is used to control the entry, while the rmcTBPlanStatus-object indicates the status. number 1.3.6.1.4.1.1206.4.2.2.5.6.1.4" REFERENCE "See Clause A.3.1" ::={ rmcMeterActionEntry 4 } rmcTBRateCtrl OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the metering rate that to be used if the metered lane is commanded by timebase control and the rmcImplementAction-object has a value of 'fixedRate'. This object is used to control the entry, while the rmcTBRateStatus-object indicates the status. This value shall be expressed in 1-vph increments. A suggested usable range is 120 to 1800. vehicles per hour 1.3.6.1.4.1.1206.4.2.2.5.6.1.5" REFERENCE "See Clause A.3.1" ::={ rmcMeterActionEntry 5 } rmcTBVehiclesPerGrnCtrl OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the number of vehicles that are allowed to pass during the green and yellow intervals of one cycle while the metered lane is commanded by timebase control. This object is used to control the entry, while the rmcTBVehiclesPerGrnStatus-object indicates the status. This value shall be expressed in 1-vehicle increments. A suggested usable range is 1 to 5. number 1.3.6.1.4.1.1206.4.2.2.5.6.1.6" REFERENCE "See Clause A.3.1" ::={ rmcMeterActionEntry 6 } rmcTBCMinMeterRateCtrl OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the operational minimum metering rate. This object is used to control the entry, while the rmcTBCMinMeterRateStatus-object indicates the status. This value shall be less than or equal to the rmcTBCMaxMeterRateCtrl-object. This value shall be expressed in 1-vph increments. A suggested usable range is 0, 120 to 1800. A value of zero (0) indicates this parameter shall not be used. vehicles per hour 1.3.6.1.4.1.1206.4.2.2.5.6.1.7" REFERENCE "See Clause A.3.1" ::={ rmcMeterActionEntry 7 } rmcTBCMaxMeterRateCtrl OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the operational maximum metering rate. This object is used to control the entry, while the rmcTBCMaxMeterRateStatus-object indicates the status. This value shall be expressed in 1-vph increments. A suggested usable range is 0, 120 to 1800. A value of zero (0) indicates this parameter shall not be used. The value, if non-zero, shall be greater than or equal to the value of the rmcTBCMinMeterRateCtrl-object. vehicles per hour 1.3.6.1.4.1.1206.4.2.2.5.6.1.8" REFERENCE "See Clause A.3.1" ::={ rmcMeterActionEntry 8 } rmcMaxNumMLTBCActions OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the maximum number of timebase control actions that can be stored in the Mainline Lane Timebase Control Action Table. number 1.3.6.1.4.1.1206.4.2.2.5.7" ::={ rmcTimebase 7 } -- USERS TAKE NOTE OF MULTIPLE VERSIONS - -- the INTEGER range was changed to start at 1 instead of 0. This -- does not cause backwards compatibility problems because this object would -- not have been supported, if the function was not supported in the device. rmcNumMLTBCActions OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the actual number of timebase control actions that are present in the Mainline Lane Timebase Control Action Table. This value shall not exceed the value of the rmcMaxNumMLTBCActions-object. number 1.3.6.1.4.1.1206.4.2.2.5.8" ::={ rmcTimebase 8 } -- USERS TAKE NOTE OF MULTIPLE VERSIONS - -- the INTEGER range was changed to start at 1 instead of 0. This -- does not cause backwards compatibility problems because this object would -- not have been supported, if the function was not supported in the device. rmcMLActionTable OBJECT-TYPE SYNTAX SEQUENCE OF RmcMLActionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing the actions for mainline lanes that can be selected based on a time based scheduler. The rows within this table are pointed to by the rmcMLActionNum-object within the rmcActionTable-object. This is a double indexed table describing what action to execute for which mainline lane.
static 1.3.6.1.4.1.1206.4.2.2.5.9" ::={ rmcTimebase 9 } rmcMLActionEntry OBJECT-TYPE SYNTAX RmcMLActionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Parameters of the Timebase Control Action Table for A mainline lane. A particular row of this table can be managed using the rmcMLActionMode- object. An action described within a row is unused when the value of that object has been set to zero (0). 1.3.6.1.4.1.1206.4.2.2.5.9.1" INDEX { rmcMLActionIndex, rmcMLNumber } ::={ rmcMLActionTable 1 } RmcMLActionEntry ::=SEQUENCE { rmcMLActionIndex INTEGER, rmcMLActionMode INTEGER, rmcTBMLUsageMode INTEGER } rmcMLActionIndex OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "Primary index to this double indexed table showing an enumerated listing of row entries. The value of the rmcMLActionNum-object is pointing to THIS object, not to a particular row. All rows that are associated with this primary key will be activated if the scheduler points to the appropriate row within the rmcActionTable. The value of this object cannot exceed the value of the rmcMaxNumMLTBCActions-object. number 1.3.6.1.4.1.1206.4.2.2.5.9.1.1" ::={ rmcMLActionEntry 1 } rmcMLActionMode OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates whether this row is used. The values are: 0 - false. This row is NOT being used 1 - true. This row is being used. 1.3.6.1.4.1.1206.4.2.2.5.9.1.2" ::={ rmcMLActionEntry 2 } rmcTBMLUsageMode OBJECT-TYPE SYNTAX INTEGER { notUsed (1), schemeF (2), schemeO (3), schemeFO (4), schemeS (5), schemeFS (6), schemeOS (7), schemeFOS (8) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates which mainline station traffic parameters will use the data from this lane based on time of day. This object shall take precedence over the value entered in the rmcMLUsageMode-object (defined in the rmcMLCtrlTable). This precedence shall be reflected in the rmcMLUsageStatus-object (defined in the rmcMLStatTable). The values are notUsed - the lane data will not be used to calculate any mainline station parameter. schemeF - the lane data will be used to calculate the mainline station flow rate schemeO - the lane data will be used to calculate the mainline station average occupancy schemeFO - the lane data will be used to calculate the mainline station flow rate and average occupancy schemeS - the lane data will be used to calculate the mainline station average speed schemeFS - the lane data will be used to calculate the mainline station flow rate and average speed schemeOS - the lane data will be used to calculate the mainline station average occupancy and occupancy speed schemeFOS - the lane data will be used to calculate the mainline station flow rate, average occupancy and average speed. 1.3.6.1.4.1.1206.4.2.2.5.9.1.3" REFERENCE "See Clause A.3.1" ::={ rmcMLActionEntry 3 } rmcInOutput OBJECT IDENTIFIER ::={ ramp 6 } -- This node is an identifier used to group all ramp meter control unit- -- specific objects supporting remote setting of input and output -- definitions. rmcAdvSignOutNumber OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the physical output number of the advance warning sign for the entire RMC. A value of 255 indicates that there is no physical output for this function. number 1.3.6.1.4.1.1206.4.2.2.6.1" REFERENCE "See Clause A.10.1" ::={ rmcInOutput 1 } rmcMLInTable OBJECT-TYPE SYNTAX SEQUENCE OF RmcMLInEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing the configuration information for mainline lane physical inputs.
static 1.3.6.1.4.1.1206.4.2.2.6.2" REFERENCE "See Clause A.10.4" ::={ rmcInOutput 2 } rmcMLInEntry OBJECT-TYPE SYNTAX RmcMLInEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Configuration parameters of the mainline lane physical input table. This table is directly correlated to the Mainline Lane Configuration and Control Table, which means that the number of rows in this table is exactly the same as the number of rows in the Mainline Lane Configuration and Control Table (AUGMENT TABLE in SNMPv2 terminology). Table management can only take place through the Mainline Lane Configuration and Control Table (rmcMLCtrlTable), while this table defines the associated physical input and outputs. 1.3.6.1.4.1.1206.4.2.2.6.2.1" INDEX { rmcMLNumber } ::={ rmcMLInTable 1 } RmcMLInEntry ::=SEQUENCE { rmcMLLeadInNumber INTEGER, rmcMLTrailInNumber INTEGER } rmcMLLeadInNumber OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the physical input number of the leading detector for this mainline lane. A value of 255 indicates that there is no physical input for this function. number 1.3.6.1.4.1.1206.4.2.2.6.2.1.1" REFERENCE "See Clause A.10.4" ::={ rmcMLInEntry 1 } rmcMLTrailInNumber OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the physical input number of the trailing detector for this mainline lane. A value of 255 indicates that there is no physical input for this function. number 1.3.6.1.4.1.1206.4.2.2.6.2.1.2" REFERENCE "See Clause A.10.4" ::={ rmcMLInEntry 2 } rmcQueueInTable OBJECT-TYPE SYNTAX SEQUENCE OF RmcQueueInEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing the configuration information for metered lane queue detection physical inputs and outputs.
static 1.3.6.1.4.1.1206.4.2.2.6.3" REFERENCE "See Clause A.10.4" ::={ rmcInOutput 3 } rmcQueueInEntry OBJECT-TYPE SYNTAX RmcQueueInEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Configuration parameters of the metered lane queue detector physical input table. This table is directly correlated to the Queue Detector Configuration and Control Table, which means that the number of rows in this table is exactly the same as the number of rows in the Queue Detector Configuration and Control Table (AUGMENT TABLE in SNMPv2 terminology). Table management can only take place through the rmcQueueDetectMode-object within Queue Detector Configuration and Control Table (rmcQueueCtrlTable), while this table defines the associated physical input. 1.3.6.1.4.1.1206.4.2.2.6.3.1" INDEX { rmcMeterNumber, rmcQueueNum } ::={ rmcQueueInTable 1 } RmcQueueInEntry ::=SEQUENCE { rmcMetQueueInNumber INTEGER} rmcMetQueueInNumber OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the physical input number of the queue detector for the associated metered lane and queue detector number. A value of 255 indicates that there is no physical input for this function. number 1.3.6.1.4.1.1206.4.2.2.6.3.1.1" REFERENCE "See Clause A.10.3.1" ::={ rmcQueueInEntry 1 } rmcMeterInOutTable OBJECT-TYPE SYNTAX SEQUENCE OF RmcMeterInOutEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing the configuration information for metered lane physical inputs and outputs.
static 1.3.6.1.4.1.1206.4.2.2.6.4" REFERENCE "See Clause A.10.3" ::={ rmcInOutput 4 } rmcMeterInOutEntry OBJECT-TYPE SYNTAX RmcMeterInOutEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Configuration parameters of the metered lane physical input/output table. This table is directly correlated to the Metered Lane Control Table, which means that the number of rows in this table is exactly the same as the number of rows in the Metered Lane Control Table (AUGMENT TABLE in SNMPv2 terminology). Table management can only take place through the Metered Lane Control Table (rmcMeterCtrlTable), while this table defines the associated physical input and outputs. 1.3.6.1.4.1.1206.4.2.2.6.4.1" INDEX { rmcMeterNumber } ::={ rmcMeterInOutTable 1 } RmcMeterInOutEntry ::=SEQUENCE { rmcMeterDemandInNumber INTEGER, rmcMeterPassageInNumber INTEGER, rmcMeterRedOutNumber INTEGER, rmcMeterYellowOutNumber INTEGER, rmcMeterGreenOutNumber INTEGER, rmcMeterAdvSignOutNumber INTEGER} rmcMeterDemandInNumber OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the physical input number of the demand detector for this metered lane. A value of 255 indicates that there is no physical input for this function. number 1.3.6.1.4.1.1206.4.2.2.6.4.1.1" REFERENCE "See Clause A.10.3" ::={ rmcMeterInOutEntry 1 } rmcMeterPassageInNumber OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the physical input number of the passage detector for this metered lane. A value of 255 indicates that there is no physical input for this function. number 1.3.6.1.4.1.1206.4.2.2.6.4.1.2" REFERENCE "See Clause A.10.3" ::={ rmcMeterInOutEntry 2 } rmcMeterRedOutNumber OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the physical output number of the red indication for this metered lane. A value of 255 indicates that there is no physical output for this function. number 1.3.6.1.4.1.1206.4.2.2.6.4.1.3" REFERENCE "See Clause A.10.3" ::={ rmcMeterInOutEntry 3 } rmcMeterYellowOutNumber OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the physical output number of the yellow indication for this metered lane. A value of 255 indicates that there is no physical output for this function. number 1.3.6.1.4.1.1206.4.2.2.6.4.1.4" REFERENCE "See Clause A.10.3" ::={ rmcMeterInOutEntry 4 } rmcMeterGreenOutNumber OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the physical output number of the green indication for this metered lane. A value of 255 indicates that there is no physical output for this function. number 1.3.6.1.4.1.1206.4.2.2.6.4.1.5" REFERENCE "See Clause A.10.3" ::={ rmcMeterInOutEntry 5 } rmcMeterAdvSignOutNumber OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the physical output number of the advance warning sign for this metered lane. A value of 255 indicates that there is no physical output for this function. number 1.3.6.1.4.1.1206.4.2.2.6.4.1.6" REFERENCE "See Clause A.10.3" ::={ rmcMeterInOutEntry 6 } rmcDependInOutTable OBJECT-TYPE SYNTAX SEQUENCE OF RmcDependInOutEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing the configuration information for dependency group physical inputs and outputs.
static 1.3.6.1.4.1.1206.4.2.2.6.5" REFERENCE "See Clause A.10.2" ::={ rmcInOutput 5 } rmcDependInOutEntry OBJECT-TYPE SYNTAX RmcDependInOutEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Configuration parameters of the dependency group physical input/output table. This table is directly correlated to the Dependency Group Configuration and Control Table, which means that the number of rows in this table is exactly the same as the number of rows in the Dependency Group Configuration and Control Table (AUGMENT TABLE in SNMPv2 terminology). Table management can only take place through the Dependency Group Configuration and Control Table (rmcDependGroupCtrlTable), while this table defines the associated physical input and outputs. 1.3.6.1.4.1.1206.4.2.2.6.5.1" INDEX { rmcDependGroupNumber } ::={ rmcDependInOutTable 1 } RmcDependInOutEntry ::=SEQUENCE { rmcDependMergeInNumber INTEGER, rmcDependAdvSignOutNumber INTEGER} rmcDependMergeInNumber OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the physical input number of the merge detector for this dependency group. A value of 255 indicates that there is no physical input for this function. number 1.3.6.1.4.1.1206.4.2.2.6.5.1.1" REFERENCE "See Clause A.10.2" ::={ rmcDependInOutEntry 1 } rmcDependAdvSignOutNumber OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the physical output number of the advance warning sign for this dependency group. A value of 255 indicates that there is no physical output for this function. number 1.3.6.1.4.1.1206.4.2.2.6.5.1.2" REFERENCE "See Clause A.10.2" ::={ rmcDependInOutEntry 2 } rmcBlock OBJECT IDENTIFIER ::= { ramp 7 } -- This object is an identifier used to group all objects for -- support of RMC Unit Block Upload and Download activities. rmcBlockGetControl OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2..12)) ACCESS read-write STATUS mandatory DESCRIPTION " An OER encoded string of reference parameters for RMC Block Uploads. The parameter values in this string are: rmcBlockDataType INTEGER (0..255) rmcBlockDataID INTEGER (0..255) rmcBlockIndex1 INTEGER (1..255) if needed rmcBlockQuantity1 INTEGER (1..255) if needed rmcBlockIndex2 INTEGER (1..255) if needed rmcBlockQuantity2 INTEGER (1..255) if needed rmcBlockIndex3 INTEGER (1..255) if needed rmcBlockQuantity3 INTEGER (1..255) if needed rmcBlockIndex4 INTEGER (1..255) if needed rmcBlockQuantity4 INTEGER (1..255) if needed rmcBlockIndex5 INTEGER (1..255) if needed rmcBlockQuantity5 INTEGER (1..255) if needed A GET of rmcBlockData shall utilize values currently in this object to define the data to be returned. A SET of this object shall be evaluated for validity and an Error Status of badValue(3) be returned for the following conditions: 1) rmcBlockDataType is not supported 2) rmcBlockDataID is not supported 3) rmcBlockIndex1 is zero or is greater than the table's maximum number of rows 4) rmcBlockQuantity1 is zero or rmcBlockIndex1 + rmcBlockQuantity1 - 1 is greater than the table's maximum number of rows 5) rmcBlockIndex2 is zero or not supported 6) rmcBlockQuantity2 is zero or rmcBlockIndex2 + rmcBlockQuantity2 - 1 is greater than the table's maximum number of rows 7) rmcBlockIndex3 is zero or is greater than the table's maximum number of rows 8) rmcBlockQuantity3 is zero or rmcBlockIndex3 + rmcBlockQuantity3 - 1 is greater than the table's maximum number of rows 9) rmcBlockIndex4 is zero or is greater than the table's maximum number of rows 10) rmcBlockQuantity4 is zero or rmcBlockIndex4 + rmcBlockQuantity4 - 1 is greater than the table's maximum number of rows 11) rmcBlockIndex5 is zero or is greater than the table's maximum number of rows 12) rmcBlockQuantity5 is zero or rmcBlockIndex5 + rmcBlockQuantity5 - 1 is greater than the table's maximum number of rows 13) if the SET length is zero or incorrect for rmcBlockDataType & rmcBlockDataID 14) if the GetResponse length for a GET on rmcBlockData using maximum data field sizes would exceed a local limitation When this validity check fails, rmcBlockErrorStatus shall be set equal to the Bullet Value above that generated the error. Because of SNMP, it cannot be determined in advance which error of multiple, simultaneous errors will be reported. 1.3.6.1.4.1.1206.4.2.2.7.1" ::= { rmcBlock 1 } rmcBlockData OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2..484)) ACCESS read-write STATUS mandatory DESCRIPTION " An OER encoded string used for uploading and downloading RMC parameters. See SECTION 4 for encoding and decoding the block. A SET on this object shall require the use of 'dbCreateTransaction' defined in NTCIP 1201 v03 Clause 2.3.1. A SET of this object shall be evaluated for validity and an Error Status of badValue(3) be returned for the following conditions: 1) rmcBlockDataType is not supported 2) rmcBlockDataID is not supported 3) rmcBlockIndex1 is zero or is greater than the table's maximum number of rows 4) rmcBlockQuantity1 is zero or rmcBlockIndex1 + rmcBlockQuantity1 - 1 is greater than the table's maximum number of rows 5) rmcBlockIndex2 is zero or is greater than the table's maximum number of rows 6) rmcBlockQuantity2 is zero or rmcBlockIndex2 + rmcBlockQuantity2 - 1 is greater than the table's maximum number of rows 7) rmcBlockIndex3 is zero or is greater than the table's maximum number of rows 8) rmcBlockQuantity3 is zero or rmcBlockIndex3 + rmcBlockQuantity3 - 1 is greater than the table's maximum number of rows 9) rmcBlockIndex4 is zero or is greater than the table's maximum number of rows 10) rmcBlockQuantity4 is zero or rmcBlockIndex4 + rmcBlockQuantity4 - 1 is greater than the table's maximum number of rows 11) rmcBlockIndex5 is zero or is greater than the table's maximum number of rows 12) rmcBlockQuantity5 is zero or rmcBlockIndex5 + rmcBlockQuantity5 - 1 is greater than the table's maximum number of rows 13) if the SET length is zero or incorrect for rmcBlockDataType & rmcBlockDataID 14) if the SET (SEQUENCE OF) value is incorrect. When this validity check fails, rmcBlockErrorStatus shall be set equal to the Bullet Value above that generated the error. Because of SNMP, it cannot be determined in advance which error of multiple, simultaneous errors will be reported. A SET that includes an unsupported value for a supported data element shall return an Error Status of badValue(3) and rmcBlockErrorStatus shall be set equal to: (data Sequence # * 100) + data Element # A SET that includes a non-zero or non-null value in the position of an unsupported data element shall return an Error Status of badValue(3) and rmcBlockErrorStatus shall be set equal to: (data Sequence # * 100) + data Element # A GET on this object shall utilize values currently in rmcBlockGetControl to define the data to be returned. When rmcBlockGetControl has invalid data, an Error Status of badValue(3) shall be returned. A GET shall return a zero or null value in the position of an unsupported object. 1.3.6.1.4.1.1206.4.2.2.7.2" ::= { rmcBlock 2 } rmcBlockErrorStatus OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION " This object defines the data element within rmcBlockGetControl or rmcBlockData objects that caused a badValue(3) Error Status. This object should equal zero after any successful SET to rmcBlockGetControl or rmcBlockData. 1.3.6.1.4.1.1206.4.2.2.7.3" ::= { rmcBlock 3 } END