-- OIDref derived MIB transcription. Original PDF: https://www.ntcip.org/file/2018/11/NTCIP1201v0232f.pdf -- Publisher front matter and notices follow as comments. -- A Joint Standard of AASHTO, ITE, and NEMA -- -- -- -- -- NTCIP 1201:2005 v02.32 -- -- -- -- National Transportation -- Communications for ITS Protocol -- -- Global Object (GO) Definitions – -- version 02 -- -- October 2005 -- -- A major revision of NTCIP 1201 v01.10, -- which included NTCIP 1201 Amendment 1 v07 -- -- -- This Adobe® PDF copy of an NTCIP standard is available at no-cost for a limited -- time through support from the U.S. DOT / Federal Highway Administration, whose -- assistance is gratefully acknowledged. -- -- -- -- -- Published by -- -- American Association of State Highway and Transportation Officials (AASHTO) -- 444 North Capitol Street, N.W., Suite 249 -- Washington, D.C. 20001 -- -- Institute of Transportation Engineers (ITE) -- 1099 14th Street, N.W., Suite 300 West -- Washington, D.C. 20005-3438 -- -- National Electrical Manufacturers Association (NEMA) -- 1300 North 17th Street, Suite 1752 -- Rosslyn, Virginia 22209-3806 -- -- -- © 2005 AASHTO / ITE / NEMA. All rights reserved -- -- NOTICES -- -- Copyright Notice -- -- Version 01 © 2001 by the National Electrical Manufacturers Association (NEMA). Version 02  2005 by -- the American Association of State Highway and Transportation Officials (AASHTO), the Institute of -- Transportation Engineers (ITE), and the National Electrical Manufacturers Association (NEMA). All -- intellectual property rights, including, but not limited to, the rights of reproduction, translation, and display -- are reserved under the laws of the United States of America, the Universal Copyright Convention, the -- Berne Convention, and the International and Pan American Copyright Conventions. Except as licensed -- or permitted, you may not copy these materials without prior written permission from AASHTO, ITE, or -- NEMA. Use of these materials does not give you any rights of ownership or claim of copyright in or to -- these materials. -- -- Visit www.ntcip.org for other copyright information, for instructions to request reprints of excerpts, and to -- request reproduction that is not granted below. -- -- -- PDF File License Agreement -- -- To the extent that these materials are distributed by AASHTO / ITE / NEMA in the form of an Adobe® -- Portable Document Format (PDF) electronic data file (the “PDF File”), AASHTO / ITE / NEMA authorizes -- each registered PDF File user to view, download, copy, or print the PDF File available from the -- authorized Web site, subject to the terms and conditions of this license agreement: -- -- (a) you may download one copy of each PDF File for personal, noncommercial, and intraorganizational -- use only; -- (b) ownership of the PDF File is not transferred to you; you are licensed to use the PDF File; -- (c) you may make one more electronic copy of the PDF File, such as to a second hard drive or burn to a -- CD; -- (d) you agree not to copy, distribute, or transfer the PDF File from that media to any other electronic -- media or device; -- (e) you may print one paper copy of the PDF File; -- (f) you may make one paper reproduction of the printed copy; -- (g) any permitted copies of the PDF File must retain the copyright notice, and any other proprietary -- notices contained in the file; -- (h) the PDF File license does not include (1) resale of the PDF File or copies, (2) republishing the content -- in compendiums or anthologies, (3) publishing excerpts in commercial publications or works for hire, -- (4) editing or modification of the PDF File except those portions as permitted, (5) posting on network -- servers or distribution by electronic mail or from electronic storage devices, and (6) translation to other -- languages or conversion to other electronic formats; -- (i) other use of the PDF File and printed copy requires express, prior written consent. -- -- -- Data Dictionary and MIB Distribution Permission -- -- To the extent that these materials are distributed by AASHTO / ITE / NEMA in the form of a Data -- Dictionary (“DD”) or Management Information Base (“MIB”), AASHTO / ITE / NEMA extend the following -- permission: -- -- You may make or distribute unlimited copies, including derivative works, of the DD or MIB, including -- copies for commercial distribution, provided that: -- (i) each copy you make or distribute contains the citation “Derived from NTCIP 0000 [insert the document -- number]. Used by permission of AASHTO / ITE / NEMA.”; -- -- -- -- Do Not Copy Without Written Permission © 2005 AASHTO / ITE / NEMA -- -- (ii) the copies or derivative works are not made part of the standards publications or works offered by -- other standards developing organizations or publishers or as works-for-hire not associated with -- commercial hardware or software products intended for field implementation; -- (iii) use of the DD or MIB is restricted in that the syntax fields may be modified only to reflect a more -- restrictive subrange or enumerated values; -- (iv) the description field may be modified but only to the extent that: (a) only those bit values or -- enumerated values that are supported are listed; and (b) the more restrictive subrange is expressed. -- -- These materials are delivered “AS IS” without any warranties as to their use or performance. -- -- AASHTO / ITE / NEMA and their suppliers do not warrant the performance or results you may -- obtain by using these materials. AASHTO / ITE / NEMA and their suppliers make no warranties, -- express or implied, as to noninfringement of third party rights, merchantability, or fitness for any -- particular purpose. In no event will AASHTO / ITE / NEMA or their suppliers be liable to you or any -- third party for any claim or for any consequential, incidental or special damages, including any -- lost profits or lost savings, arising from your reproduction or use of these materials, even if an -- AASHTO / ITE / NEMA representative has been advised of the possibility of such damages. -- -- Some states or jurisdictions do not allow the exclusion or limitation of incidental, consequential or special -- damages, or the exclusion of implied warranties, so the above limitations may not apply to you. -- -- Use of these materials does not constitute an endorsement or affiliation by or between AASHTO, ITE, or -- NEMA and you, your company, or your products and services. -- -- If you are unwilling to accept the foregoing restrictions, you should immediately return these materials. -- -- -- PRL and RTM Distribution Permission -- -- To the extent that these materials are distributed by AASHTO / ITE / NEMA in the form of a Profile -- Requirements List (“PRL”) or a Requirements Traceability Matrix (“RTM”), AASHTO / ITE / NEMA extend -- the following permission: -- -- (i) you may make and/or distribute unlimited copies, including derivative works of the PRL (then known as -- a Profile Implementation Conformance Statement (“PICS”)) or the RTM, provided that each copy you -- make and/or distribute contains the citation “Based on NTCIP 0000 [insert the document number] PRL or -- RTM. Used by permission. Original text © AASHTO / ITE / NEMA.”; -- (ii) you may not modify the PRL or the RTM except for the Project Requirements column, which is the -- only column that may be modified to show a product’s implementation or the project-specific -- requirements; and -- (iii) if the PRL or RTM excerpt is made from an unapproved draft, add to the citation “PRL (or RTM) -- excerpted from a draft document containing preliminary information that is subject to change.” -- -- This limited permission does not include reuse in works offered by other standards developing -- organizations or publishers, and does not include reuse in works-for-hire, compendiums, or electronic -- storage devices that are not associated with commercial hardware or software products intended for field -- installation. -- -- A PICS is a Profile Requirements List which is completed to indicate the features that are supported in an -- implementation. Visit www.ntcip.org for information on electronic copies of the MIBs, PRLs, and RTMs. -- -- -- -- -- © 2005 AASHTO / ITE / NEMA Do Not Copy Without Written Permission -- -- TRF Distribution Permission [when standard contains a TRF] -- -- To the extent that these materials are distributed by AASHTO / ITE / NEMA in the form of a Testing -- Requirements Form (“TRF”), AASHTO / ITE / NEMA extend the following permission: -- -- (i) you may make or distribute unlimited electronic or hard copies, including derivative works of the TRF, -- provided that each copy you make or distribute contains the citation “Based on NTCIP 0000 [insert the -- document number] TRF. Used by permission. Original text © AASHTO / ITE / NEMA.”; -- (ii) you may not modify the logical flow of any test procedure, without clearly noting and marking any such -- modification; and -- (iii) if the TRF excerpt is made from an unapproved draft, add to the citation “TRF excerpted from a draft -- document containing preliminary information that is subject to change.” -- -- -- Content and Liability Disclaimer -- -- The information in this publication was considered technically sound by the consensus of persons -- engaged in the development and approval of the document at the time it was developed. Consensus -- does not necessarily mean that there is unanimous agreement among every person participating in the -- development of this document. -- -- AASHTO, ITE, and NEMA standards and guideline publications, of which the document contained herein -- is one, are developed through a voluntary consensus standards development process. This process -- brings together volunteers or seeks out the views of persons who have an interest in the topic covered by -- this publication. While AASHTO, ITE, and NEMA administer the process and establish rules to promote -- fairness in the development of consensus, they do not write the document and they do not independently -- test, evaluate, or verify the accuracy or completeness of any information or the soundness of any -- judgments contained in their standards and guideline publications. -- -- AASHTO, ITE, and NEMA disclaim liability for any personal injury, property, or other damages of any -- nature whatsoever, whether special, indirect, consequential, or compensatory, directly or indirectly -- resulting from the publication, use of, application, or reliance on this document. AASHTO, ITE, and -- NEMA disclaim and make no guaranty or warranty, express or implied, as to the accuracy or -- completeness of any information published herein, and disclaims and makes no warranty that the -- information in this document will fulfill any of your particular purposes or needs. AASHTO, ITE, and -- NEMA do not undertake to guarantee the performance of any individual manufacturer or seller’s products -- or services by virtue of this standard or guide. -- -- In publishing and making this document available, AASHTO, ITE, and NEMA are not undertaking to -- render professional or other services for or on behalf of any person or entity, nor are AASHTO, ITE, and -- NEMA undertaking to perform any duty owed by any person or entity to someone else. Anyone using this -- document should rely on his or her own independent judgment or, as appropriate, seek the advice of a -- competent professional in determining the exercise of reasonable care in any given circumstances. -- Information and other standards on the topic covered by this publication may be available from other -- sources, which the user may wish to consult for additional views or information not covered by this -- publication. -- -- AASHTO, ITE, and NEMA have no power, nor do they undertake to police or enforce compliance with the -- contents of this document. AASHTO, ITE, and NEMA do not certify, test, or inspect products, designs, or -- installations for safety or health purposes. Any certification or other statement of compliance with any -- health or safety–related information in this document shall not be attributable to AASHTO, ITE, or NEMA -- and is solely the responsibility of the certifier or maker of the statement. -- -- -- -- -- Do Not Copy Without Written Permission © 2005 AASHTO / ITE / NEMA -- -- Trademark Notice -- -- NTCIP is a trademark of AASHTO / ITE / NEMA. All other marks mentioned in this document are the -- trademarks of their respective owners. -- -- -- -- -- © 2005 AASHTO / ITE / NEMA Do Not Copy Without Written Permission -- -- < This page is intentionally left blank. > -- -- -- -- -- Do Not Copy Without Written Permission © 2005 AASHTO / ITE / NEMA -- -- NTCIP 1201:2005 v02.32 -- Page i -- -- -- ACKNOWLEDGEMENTS -- -- This publication was prepared by the NTCIP Global Object Working Group, which is a subdivision of the -- Joint Committee on the NTCIP. The Joint Committee is organized under a Memorandum of -- Understanding among the American Association of State Highway and Transportation Officials -- (AASHTO), the Institute of Transportation Engineers (ITE), and the National Electrical Manufacturers -- Association (NEMA). The Joint Committee on the NTCIP consists of six representatives from each of the -- standards organizations, and provides guidance for NTCIP development. -- -- At the time that this document was prepared, the following individuals were members of the NTCIP -- Global Object Working Group: -- • Bob De Roche -- • Curtis Herrick -- • Paul Hing -- • Bud Kent -- • Larry Lindley -- • Joerg “Nu” Rosenbohm -- • Ken Vaughn (Chair) -- -- Other individuals providing input to the document, include: -- • Moon Chueng -- • Blake Christie -- • Mike Forbis -- • Craig Gardner -- • Robert Martindale -- • Gary Meredith -- • Jeris White -- -- In addition to the many volunteer efforts, recognition is also given to those organizations who supported -- the efforts of the working groups by providing comments and funding for the standard, including: -- • U.S. Department of Transportation, Federal Highway Administration -- • Econolite Control Products, Inc. -- • G. C. Herrick & Associates, Inc. -- • Iteris, Inc. -- • Ministry of Ontario -- • Mitretek -- • PB Farradyne, a Division of PBQD, Inc. -- • Peek Transportation Systems -- • Robert De Roche Consulting, Inc. -- • Siemens ITS -- • Trevilon -- • Washington State Department of Transportation -- -- This publication and version is dedicated to the memory of Curtis Herrick. -- -- -- -- -- © 2005 AASHTO / ITE / NEMA Do Not Copy Without Written Permission -- -- NTCIP 1201:2005 v02.32 -- Page ii -- -- -- FOREWORD -- -- This document uses only metric units. -- -- The purpose of this publication is to identify and define the common object definitions that may be -- supported by devices that are NTCIP-compliant. -- -- This document is an NTCIP Device Data Dictionary standard. Device Data Dictionary standards provide -- definitions of data elements for use within NTCIP systems. A Joint NTCIP data dictionary standards -- publication is equivalent to these document types at the standards organizations: -- -- AASHTO – Standard Specification -- ITE – Software Standard -- NEMA – Standard -- -- For more information about NTCIP standards, visit the NTCIP Web site at http://www.ntcip.org. -- -- -- User Comment Instructions -- -- The term “User Comment” includes any type of written inquiry, comment, question, or proposed revision, -- from an individual person or organization, about any part of this standard publication’s content. A -- “Request for Interpretation” of this standard publication is also classified as a User Comment. User -- Comments are solicited at any time. In preparation of this NTCIP standards publication, input of users -- and other interested parties was sought and evaluated. -- -- All User Comments will be referred to the committee responsible for developing and/or maintaining this -- standards publication. The committee chairperson, or their designee, may contact the submitter for -- clarification of the User Comment. When the committee chairperson or designee reports the committee’s -- consensus opinion related to the User Comment, that opinion will be forwarded to the submitter. The -- committee chairperson may report that action on the User Comment may be deferred to a future -- committee meeting and/or a future revision of the standards publication. Previous User Comments and -- their disposition may be available for reference and information at www.ntcip.org. -- -- A User Comment should be submitted to this address: -- -- NTCIP Coordinator -- National Electrical Manufacturers Association -- 1300 North 17th Street, Suite 1752 -- Rosslyn, Virginia 22209-3801 -- fax: (703) 841-3331 -- e-mail: ntcip@nema.org -- -- A User Comment should be submitted in the following form: -- -- Standard Publication number and version: -- Page: -- Paragraph or Clause: -- Comment: -- -- Please include your name, organization, and address in your correspondence. -- -- -- -- -- Do Not Copy Without Written Permission © 2005 AASHTO / ITE / NEMA NTCIP1201-2004 DEFINITIONS ::= BEGIN -- NTCIP 8004 Header -- Entity Type -- Controller -- ITS -- A microprocessor, typically located in the field, that controls and/or monitors a wayside -- device of interest to an ITS management system. --For the purpose of this section, the following OBJECT IDENTIFIERS are used: IMPORTS OBJECT-TYPE FROM RFC-1212 DisplayString FROM RFC1213-MIB devices, protocols, profiles, global FROM NTCIP8004-A-2004 Opaque, Counter, Gauge, null FROM RFC1155-SMI; -- global OBJECT IDENTIFIER ::= { devices 6 } globalConfiguration OBJECT IDENTIFIER ::= { global 1 } --This node is an identifier used to group all objects for support of configuration functions -- that are common to most device types. globalSetIDParameter OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Specifies a relatively unique ID (e.g., this could be a counter, a check-sum, etc.) for current values stored in all user-changeable static database objects of the particular device- type currently implemented in the device. This value shall be calculated on the change of any static database object. The value reported by this object shall not change unless there has been a change in the static data since the last request; however a genErr shall be returned if the unique ID value has not yet been updated. A management station will be able to detect any change in the static database objects by monitoring this value after it has established a baseline. Often this ID is calculated using a CRC algorithm. Controller.databaseID:number Data Element" ::= { globalConfiguration 1} globalMaxModules OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "The number of rows that are listed in the globalModuleTable. ModuleTable.maxModules:quantity Data Element module" ::= { globalConfiguration 2} globalModuleTable OBJECT-TYPE SYNTAX SEQUENCE OF ModuleTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing information regarding manufacturer of software and hardware and the associated module models and version numbers as well as an indicator if the module is hardware or software related. The number of rows in this table shall equal the value of the globalMaxModules object. ModuleTable Entity Type static" ::= { globalConfiguration 3 } moduleTableEntry OBJECT-TYPE SYNTAX ModuleTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This object defines an entry in the module table. Module Entity Type" INDEX { moduleNumber } ::= { globalModuleTable 1 } ModuleTableEntry ::= SEQUENCE { moduleNumber INTEGER, moduleDeviceNode OBJECT IDENTIFIER, moduleMake OCTET STRING, moduleModel OCTET STRING, moduleVersion OCTET STRING, moduleType INTEGER } moduleNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "This object contains the row number (1..255) within this table for the associated module. Module.number:identifier Data Element" ::= { moduleTableEntry 1 } moduleDeviceNode OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "This object contains the device node number of the device-type, e.g., an ASC signal controller would have an OID of 1.3.6.1.4.1.1206.4.2.1. Module.deviceNode:identifier Data Element" ::= { moduleTableEntry 2 } moduleMake OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the manufacturer of the associated module. A null-string shall be transmitted if this object has no entry. Module.make:text Data Element" ::= { moduleTableEntry 3 } moduleModel OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the model number (hardware) or firmware reference (software) of the associated module. A null- string shall be transmitted if this object has no entry. Module.model:text Data Element" ::= { moduleTableEntry 4 } moduleVersion OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the version of the associated module. If the moduleType has a value of software, the value of this object shall include the date on which the software was released as a string in the form of YYYYMMDD, it shall be followed by a space, a hyphen, another space, the lower-case letter ‘v’, followed by a version or configuration number. Preceding zeros shall be required for the date. For example, version 7.03.02 of the software released on July 5, 2002 would be presented as 20020705 – v7.03.02 A null-string shall be transmitted if this object has no entry. Module.version:text Data Element" ::= { moduleTableEntry 5 } moduleType OBJECT-TYPE SYNTAX INTEGER { other (1), hardware (2), software (3) } ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies if the associated module is a hardware or software module. Module.type:code Data Element" ::= { moduleTableEntry 6 } controllerBaseStandards OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) ACCESS read-only STATUS mandatory DESCRIPTION "An ASCII string that shall identify all of the standard document numbers that define or reference MIBs upon which the device is based. Where applicable, profiles shall be referenced rather than the base standards. The string shall be constructed as follows: The acronym of the standards development organization (or other body) that developed and approved the standard; a space; the standards document number; a colon; and the documents version number as designated by the standards development organization (or other body). Separate entries in the list of standards shall be separated by a carriage return (0x0d) and line feed (0x0a). In the case of NTCIP documents prior to formal approval, the version number shall be the version number in the form of lower case ‘v’ followed by the major version followed by a period followed by the minor revision. In the case of approved NTCIP standards, the version number shall be the four digit year of publication followed by a space and the version string indicated above. In the case of amended NTCIP standards, it shall consist of the four digit year of publication of the published standard followed by the upper case letter ‘A’, followed by the amendment number. For example, a message sign may have the following value for this object: Controller.baseStandards:text Data Element" ::= { globalConfiguration 4 } globalDBManagement OBJECT IDENTIFIER ::= { global 2 } -- This node is an identifier used to group those objects used to manage a transaction. -- A transaction is a SET of one or more database parameters that have interrelationships with other -- database parameters, as such a SET for any one of these objects must be validated against a set of -- consistency checks and may potentially require the setting of a large number of objects -- simultaneously. Thus, the mode described by these objects allow for such a large database download. -- Any device standard that allows this feature shall define which objects are -- database parameters versus status or control objects. dbCreateTransaction OBJECT-TYPE SYNTAX INTEGER { normal (1), transaction (2), verify (3), done (6) } ACCESS read-write STATUS mandatory DESCRIPTION "This object provides transaction control for device configuration. The transaction mode changes the behavior of the agent to force buffering of database objects until all related database objects have been modified. In the normal mode, SET operations to any database object shall either be stored in a device’s database immediately with no regard to whether other changes will be made or be rejected (as defined in the device- specific Information Profile). In the transaction mode, SET operations to any database object shall be buffered until a verify state performs a consistency check. When the consistency check completes, the device automatically transitions to the done state where a normal or transaction command may be issued. A database object is a user provided piece of setup information (or it may be defined in an information profile) that is necessary for the proper operation of a device. It is static in nature in that the agent would never change it without direction from the management station. For example, a parameter that defines a default mode of operation would be a database object. A parameter that indicates the current state of the device would not be a database object. The states and commands are defined as: NORMAL: SET operations behave as normal SETs and shall have an immediate effect on the value of any database objects used by the device if none of the objects contained in the operation require the use of the transaction mode (as defined in the device-specific Information Profile). A SET operation containing any database object that requires the use of transaction mode shall result in a genErr. This is the default state of this object. The only command that may be written to dbCreateTransaction while in this state is TRANSACTION. Any other values written to this object in this state shall result in an error response of ‘badValue’. TRANSACTION: A SET operation of one or more database objects that use the same community name as used in the request for the TRANSACTION state are buffered by the agent device for later consistency checks and a normal response is returned. A SET operation of one or more database objects using different community names shall result in a genErr with the index set to zero. A SET operation without a community name field (e.g., an STMP operation) shall be buffered by the agent device for later consistency checks and a normal response is returned. Standard SYNTAX checking shall take place at the time of the SET operation. A transaction may consist of multiple SET operations over multiple frames. A SET operation for one or more non-database objects shall be processed as normal even if it uses another community name, except for this (i.e., the dbCreateTransaction) object. A SET operation containing both database and non-database objects shall be processed in full according to these two rules. Thus, if it contains the same community name as used in the request for the TRANSACTION state, the non-database objects shall be stored immediately while the database objects shall be buffered. If it uses a different community name, the entire request will be rejected and a genErr with an index of zero shall be returned. GET operations on any object shall return the values of the data stored in the controller and shall ignore any values contained in the buffer. Any valid community name may read this (dbCreateTransaction) object when in this state, but only the community name used to command the object to the transaction mode and the administrator community name can set this object. A set from any other community name shall result in a genErr with an index of zero. The only commands that can be written to dbCreateTransaction while in this state are VERIFY and NORMAL. A VERIFY command will change the state to VERIFY. If a NORMAL command is received, all buffered data is discarded and the state is returned to NORMAL. Any other values written to this object when in this state shall result in an error response of ‘badValue’. VERIFY: Specific database objects are checked for consistency. When consistency checks are complete the device will automatically advance to the DONE state. The state of dbCreateTransaction cannot be changed when in the VERIFY state. Any values written to this object in this state shall result in an error response of ‘badValue’. The consistency check analyzes certain critical objects 'in context' and treats them as an interrelated whole rather than separate non-related data items. The consistency check rules are not defined in this standard. They are device and implementation specific. Where applicable, the consistency check rules are defined in application specific object definition standards. A specific implementation may add additional checks beyond those defined in the standards. A SET operation containing any database objects while in the VERIFY state shall result in a genErr with the index set to zero. DONE: This state is entered automatically once consistency checks have completed in the VERIFY mode. The value of dbVerifyStatus and dbVerifyError indicate whether the consistency check found any errors. A SET operation containing any database objects while in the DONE state shall result in a genErr with the index set to zero. Any valid community name may read this (dbCreateTransaction) object when in this state, but only the community name used to command the object to the transaction mode and the administrator community name can set this object. A set from any other community name shall result in a genErr with an index of zero. The only commands that can be written to dbCreateTransaction while in this state are NORMAL and TRANSACTION. Any other values written to this object in this state shall result in an error response of ‘badValue’. If a NORMAL command is issued and dbVerifyStatus indicates doneWithNoError, the buffered data is transferred to the device memory and the state is returned to NORMAL. If a NORMAL command is issued and dbVerifyStatus indicates something other than doneWithNoError then the buffered data is discarded and the state is returned to NORMAL. If a TRANSACTION command is issued, regardless of dbVerifyStatus, no action takes place (the buffered data is not changed) and the TRANSACTION state is re-entered. COMMANDED STATE (9) transaction verify normal done normal transaction (1) normal (2) normal (2) normal (2) CURRENT transaction transaction (2) verify (3) normal (4) transaction (2) STATE verify (7) verify (2) verify(2) verify (2) verify (2) done (8) transaction (5) done(2) normal (6) done (2) Operational procedures and error responses: (1) Once a copy of all database objects is placed in a buffer the state is changed to transaction and error response indicates noError. If the operation fails, the state remains the same and error response indicates genErr. (2) No action takes place, the state remains the same, but response indicates badValue. (3) The state is changed to verify, a consistency check is started, and response indicates noError. Once the consistency check is completed, the state automatically changes to done. (4). The buffered copy of all database objects is discarded, the state is changed to normal, and response indicates noError. (5) The buffered copy of all database objects is not changed or reloaded, the state is changed to transaction, and response indicates noError. (6) If dbVerifyStatus indicates doneWithNoError, then the copy of all database objects is transferred to memory, the state is changed to normal and response indicates noError. If dbVerifyStatus indicates doneWithError then the buffered data is discarded, the state is changed to NORMAL, and response indicates noError. (7) The state will automatically change to done when the consistency check completes. (8) dbVerifyStatus and dbVerifyError are only valid in this state. (9) All SET operations on this (dbCreateTransaction) parameter shall be made using a protocol that uses a community name, or equivalent field (e.g., SNMP). Transaction.mode:code Data Element" DEFVAL {normal} ::= { globalDBManagement 1 } -- This object has been deprecated. See Clause B.1 for more information. dbErrorType OBJECT-TYPE SYNTAX INTEGER { tooBig (1), noSuchName (2), badValue (3), readOnly (4), genError (5), updateError (6), noError (7)} ACCESS read-only STATUS deprecated DESCRIPTION "This object returns the current error status of the transaction. The value of this object is only valid when the dbCreateTransaction object is in the Done or Error state." ::= { globalDBManagement 2 } -- This object has been deprecated. See Clause B.1 for more information. dbErrorID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS deprecated DESCRIPTION "This object contains the object identifier of the first object in the transaction buffer that caused an error while dbCreateTransaction object was in the Verifying or Updating state. The value of this object is only valid when the dbCreateTransaction object is in the Error state. It is undefined when the dbCreateTransaction object is in other states." ::= { globalDBManagement 3 } -- This object has been deprecated. See Clause B.1 for more information. dbTransactionID OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS deprecated DESCRIPTION "This object contains the transaction ID value that is to be contained in all SET operation writes while the dbCreateTransaction object is not in the Normal state. During transaction operations every SET command shall begin with a write to this object with the current value of this object. If a SET operation is performed without writing to this object, or with a value that does not match the current value, then an error response of ‘genError’ shall be returned. This mechanism is used to determine that the same management station that started the transaction is performing the SET operations that are being buffered or modifying the state of dbCreateTransaction." ::= { globalDBManagement 4 } -- This object has been deprecated. See Clause B.1 for more information. dbMakeID OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS deprecated DESCRIPTION "This object is used to create unique transaction ID’s for management stations to use when starting transactions using the dbCreateTransaction object. This object will be incremented by one every time it is read, so that different values will be returned for each read. Management stations wishing to start a transaction should first read the dbCreateTransaction object to verify that it is in the Normal state. If so then the management shall GET dbMakeID to obtain a transaction ID to use, then SET dbCreateTransaction to startCmd and dbTransactionID to the value just received. If the response to the SET operation is ‘noError’ then the management station has started a transaction. If the response to the SET operation is ‘genError’ then the management station should read the dbCreateTransaction and dbTransactionID objects to ensure that the error was not due to a communications retry. If the dbCreateTransaction is in the Transaction state, and the dbTransactionID is the same value returned by the read of this object, then the management station is the owner of the transaction. If the dbTransactionID does not match the value originally returned by this object, then the management station is not the owner of the transaction and must wait until the dbCreateTransaction object returns to the Normal state before attempting to start the transaction." ::= { globalDBManagement 5 } dbVerifyStatus OBJECT-TYPE SYNTAX INTEGER { notDone (1), doneWithError (2), doneWithNoError (3) } ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the current status of verify (consistency checking) processing. The value of this object is only meaningful when the dbCreateTransaction object is in the Verify or Done state. Transaction.verifyStatus:code Data Element" ::= { globalDBManagement 6 } dbVerifyError OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "This object contains a textual description of or a reference to an error that was found by the verify (consistency checking) processing. The value of this object is only meaningful when the dbCreateTransaction object is in the Done state and the dbVerifyStatus object is in the doneWithError state. Transaction.errorMessage:text Data Element" ::= { globalDBManagement 7 } globalTimeManagement OBJECT IDENTIFIER ::= { global 3 } -- This node is an identifier used to organize all objects for support of time-related -- functions that are common to most device types. globalTime OBJECT-TYPE SYNTAX Counter ACCESS read-write STATUS mandatory DESCRIPTION "The number of seconds since the epoch of 00:00:00 (midnight) January 1, 1970 UTC (a.k.a. Zulu or GMT). Controller.globalTime:quantity Data Element second" DEFVAL { 0 } ::= { globalTimeManagement 1} globalDaylightSaving OBJECT-TYPE SYNTAX INTEGER { other (1), disableDST (2), enableUSDST (3), enableEuropeDST (4), enableAustraliaDST (5), enableTasmaniaDST (6), enableEgyptDST (7), enableNamibiaDST (8), enableIraqDST (9), enableMangoliaDST (10), enableIranDST (11), enableFijiDST (12), enableNewZealandDST (13), enableTongaDST (14), enableCubaDST (15), enableBrazilDST (16), enableChileDST (17), enableFalklandsDST (18), enableParaguayDST (19) } ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies if the Daylight Savings Time (DST) is enabled, disabled or some other form of daylight savings time is active. other - DST adjustments by a mechanism not defined within this standard. disableDST - DST clock adjustments shall NOT occur. enableUSDST - DST shall begin the first Sunday in April and shall end the last Sunday of October. All changes of time occur at 2:00 AM. enableEuropeDST - DST shall start the last Sunday of March at 2:00 AM and ends the last Sunday of October at 3:00 AM. enableAustraliaDST - DST shall start the last Sunday in October at 2:00 AM and ends the last Sunday in March at 2:00 AM. enableTasmaniaDST - DST shall start the first Sunday in October at 2:00 AM and ends the last Sunday in March at 3:00 AM. enableEgyptDST – DST shall start the last Friday in April and end the last Thursday in September. enableNamibiaDST – DST shall start the first Sunday in September and end the first Sunday in April. enableIraqDST – DST shall start on April 1 and end on October 1. enableMongoliaDST – DST shall start the last Sunday in March and end the last Sunday in September. enableIranDST – DST shall start the first day of Farvardin and end the first day of Mehr enableFijiDST – DST shall start the first Sunday in November and end the last Sunday in February. enableNewZealandDST – DST shall start the first Sunday in October and end the first Sunday on or after March 5th. enableTongaDST – DST shall start the first Saturday in October and end the first Saturday on or after April 15th. enableCubaDST – DST shall start April 1st and end last Sunday in October. enableBrazilDST – DST shall start the first Sunday in October and end the last Sunday in February. enableChileDST – DST shall start the first Sunday on or after October 9th and end the first Sunday on or after March 9th. enableFalklandsDST – DST shall start the first Sunday on or after September 8th and end the first Sunday on or after April 8th. enableParaguayDST – DST shall start the first Sunday in October and end the last Saturday in February. Controller.daylightSavingsMode:code Data Element" REFERENCE "NEMA TS 2 Clause 3.8.2; http://fatty.law.cornell.edu/uscode/15/260a.html; http://www.timing.se/Daylight.htm; http://www.dstc.qut.edu.au/DST/marg/daylight.html#cutoffs; http://www.dstc.qut.edu.au/DST/marg/daylight.html#cutoffs; http://webexhibits.org/daylightsaving/g.html " DEFVAL { disableDST } ::= { globalTimeManagement 2 } timebase OBJECT IDENTIFIER ::= { globalTimeManagement 3 } -- This node is an identifier used to organize the main objects for event scheduling. -- Device type-specific objects (tables) pointed to are defined within the appropriate MIB. maxTimeBaseScheduleEntries OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object specifies the maximum number of different entries supported by the device as shown by the number of rows in the timeBaseScheduleTable. TimeBaseScheduleTable.maxEntries:quantity Data Element TimeBaseScheduleEntry" ::= { timebase 1 } timeBaseScheduleTable OBJECT-TYPE SYNTAX SEQUENCE OF TimeBaseScheduleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing the time base schedule parameters for the device. The number of rows in this table shall be equal to the maxTimeBaseScheduleEntries object. The table references the appropriate day plan for the device. The plan is determined by comparing the current month (MONTH), day of week (DOW) and date of month (DOM) to the appropriate fields. The settings for MONTH, DOW and DOM are connected with a logical AND. In order to determine which timebased event to select, determine the event which has the most specific date specified. Select the more specific event based on their MONTH settings; if the same, select the most specific DOM; if that is still the same, select the most specific DOW; if that’s still the same, the first occurrence within the time base event table shall be selected. ’More specific’ means the least number of bits set within an object. All entries in Time Base Schedule Table are expressed in local time and date. A row in the table may be deactivated by setting the Month, Day, Date, or DayPlan parameters to zero (0) TimeBaseScheduleTable Entity Type static" ::= { timebase 2 } timeBaseScheduleEntry OBJECT-TYPE SYNTAX TimeBaseScheduleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Event Parameters for the time based schedule programming of the device. TimeBaseSchedule Entity Type" INDEX { timeBaseScheduleNumber } ::= { timeBaseScheduleTable 1 } TimeBaseScheduleEntry ::= SEQUENCE { timeBaseScheduleNumber INTEGER, timeBaseScheduleMonth INTEGER, timeBaseScheduleDay INTEGER, timeBaseScheduleDate INTEGER, timeBaseScheduleDayPlan INTEGER } timeBaseScheduleNumber OBJECT-TYPE SYNTAX INTEGER (1..65535 ) ACCESS read-only STATUS mandatory DESCRIPTION "The time base schedule number for objects in this row. The value of this object shall not exceed the value of the maxTimeBaseScheduleEntries object. The activation of a scheduled entry shall occur whenever allowed by all other objects within this table. TimeBaseSchedule.number:identifier Data Element" ::= { timeBaseScheduleEntry 1 } timeBaseScheduleMonth OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The Month(s) Of the Year that the schedule entry shall be allowed. Each bit represents a specific month. If the bit is set to one (1), then the scheduled entry shall be allowed during the associated month. If the bit is zero (0), then the scheduled entry shall not be allowed during the associated month. The bits are defined as: Bit Month of Year 0 Reserved 1 January 2 February 3 March 4 April 5 May 6 June 7 July 8 August 9 September 10 October 11 November 12 December 13 - 15 Reserved Thus, a value of six (6) would indicate that the entry would only be allowed during the months of January and February. A value of zero (0) shall indicate that this row has been disabled. TimeBaseSchedule.monthMask:code Data Element" ::= { timeBaseScheduleEntry 2 } timeBaseScheduleDay OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "The Day(s) Of Week that the schedule entry shall be allowed. Each bit represents a specific day of the week. If the bit is set to one (1), then the scheduled entry shall be allowed during the associated DOW. If the bit is set to zero (0), then the scheduled entry shall not be allowed during the associated DOW. The bits are defined as: Bit Day of Week 0 Reserved ('Holiday', not defined by this standard) 1 Sunday 2 Monday 3 Tuesday 4 Wednesday 5 Thursday 6 Friday 7 Saturday Thus, a value of six (6) would indicate that the entry would only be allowed on Sundays and Mondays. A value of zero (0) shall indicate that this row has been disabled. TimeBaseSchedule.dayMask:code Data Element" ::= { timeBaseScheduleEntry 3 } timeBaseScheduleDate OBJECT-TYPE SYNTAX INTEGER (0..4294967295) ACCESS read-write STATUS mandatory DESCRIPTION "The Day(s) Of a Month that the schedule entry shall be allowed. Each bit represents a specific date of the month. If the bit is set to one (1), then the scheduled entry shall be allowed during the associated date. If the bit is set to zero (0), then the scheduled entry shall not be allowed during the associated date. The bits are defined as: Bit Day Number 0 Reserved 1 Day 1 2 Day 2 || 31 Day 31 Thus, a value of six (6) would indicate that the entry would only be allowed on the first and second of the allowed months. A value of zero (0) shall indicate that this row has been disabled. TimeBaseSchedule.dateMask:code Data Element" ::= { timeBaseScheduleEntry 4 } timeBaseScheduleDayPlan OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies what Plan number shall be associated with this timeBaseScheduleDayPlan -object. A value of zero (0) shall indicate that this row has been disabled. TimeBaseSchedule.dayPlan:identifier Data Element" ::= { timeBaseScheduleEntry 5 } timeBaseScheduleTableStatus OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the number of the TimeBaseSchedule which is currently selected by the scheduling logic; the device may or may not be using the selected schedule. The value of zero (0) indicates that there is no timeBaseScheduleNumber that is currently selected. TimeBaseScheduleTable.status:identifier Data Element" ::={timebase 7} maxDayPlans OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object specifies the maximum, fixed number of different timebased Day Plans supported by the device. The value of this object represents the number of day plans (primary key into the table) available in the timeBaseDayPlanTable. DayPlanTable.maxDayPlans:quantity Data Element DayPlan" ::= { timebase 3 } maxDayPlanEvents OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object specifies the fixed number of different timebased Day Plan Events within each Day Plan supported by the device. The value of this object represents the number of rows (secondary key into the table) available within each of the day plans that are available in the timeBaseDayPlanTable. All day plans shall have the same number of day plan events available for use. DayPlanTable.maxDayPlanEvents:quantity Data Element DayPlanEvent" ::= { timebase 4 } timeBaseDayPlanTable OBJECT-TYPE SYNTAX SEQUENCE OF TimeBaseDayPlanEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing day plan numbers, the times when to implement them and the associated actions. The number of rows in this table shall be equal to the product of the maxDayPlans object and the maxDayPlanEvents object. The dayPlanNumbers within this table shall begin with day plan number 1 and increment by one to the maxDayPlans. The dayPlanEventNumbers within this table shall begin with day plan event number 1 and increment by one to the maxDayPlanEvents. This table is always used in association with device-type specific objects specifying device-type specific actions such as activating a message on a VMS sign or initiating a pattern for a signal controller. A device MIB that defines an action table should define the relative priority of the action table as compared to the priority of system and other commands. The device-type specific action will only be initiated when (1) the specific DayPlan has been activated, (2) the scheduler has sufficient priority to override the current operation of the device, and (3) at the indicated time. After a power recovery or after a change to globalTime, the operational mode called for by the scheduler shall be per the last event that would have been called by the currently defined schedule; the logic will search for all events that may have occurred for at least the previous 24 hours. DayPlanTable Entity Type static" ::= { timebase 5 } timeBaseDayPlanEntry OBJECT-TYPE SYNTAX TimeBaseDayPlanEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing the timebased day plan parameters of a device. DayPlan Entity Type" INDEX { dayPlanNumber, dayPlanEventNumber} ::= { timeBaseDayPlanTable 1 } TimeBaseDayPlanEntry ::= SEQUENCE { dayPlanNumber INTEGER, dayPlanEventNumber INTEGER, dayPlanHour INTEGER, dayPlanMinute INTEGER, dayPlanActionNumberOID OBJECT IDENTIFIER } dayPlanNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the day plan number for objects in this row. The value shall not exceed the value of the maxDayPlans object. Day plan numbers are used in the TimeBase Event Table to specify day plan numbers to be implemented on specific days of the year or as part of the week plans. DayPlan.number:identifier Data Element" ::= { timeBaseDayPlanEntry 1 } dayPlanEventNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies day plan event number(s) to be scheduled on a specific day plan number. Several different events can be scheduled to take place during a day, and each of these events is one entry or row within a specified day plan number. The total number of events for one day plan shall not exceed the value of the maxDayPlanEvents object. If multiple non-conflicting events occur at the same time, they shall be logically executed in order of their dayPlanEventNumber with the lowest number occurring first. An implementation shall omit lower number actions that are in conflict with higher number actions at the same time. DayPlanEvent.number:identifier Data Element" ::= { timeBaseDayPlanEntry 2 } dayPlanHour OBJECT-TYPE SYNTAX INTEGER (0..23) ACCESS read-write STATUS mandatory DESCRIPTION "The Hour of day, as measured by the controllerLocalTime object, that the associated event shall become active. DayPlanEvent.hour:number Data Element" DEFVAL {0} ::= { timeBaseDayPlanEntry 3 } dayPlanMinute OBJECT-TYPE SYNTAX INTEGER (0..59) ACCESS read-write STATUS mandatory DESCRIPTION "The Minute of the hour (defined in the dayPlanHour), as measured by the controllerLocalTime object, that the associated event shall become active. DayPlanEvent.minute:number Data Element" DEFVAL {0} ::= { timeBaseDayPlanEntry 4 } dayPlanActionNumberOID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-write STATUS mandatory DESCRIPTION "This object provides a reference to the device-type specific action that shall be executed. The object shall reference the action by its associated object identifier, including its instance (i.e., the full OID of the scalar or columnar object). Only objects whose description field explicitly states that they may be called by the action table may be referenced. If a management system attempts to set this value to any other object identifier, the device shall respond with a genErr. Any object allowing the action table to reference it shall define precisely what action will take place when it is activated and whether the action is transitionary or continuous until deactivated. The object shall also define what, if any, restrictions may be placed on other operations the device may be able to perform. If the action to be performed is defined by a row of a table, one of the index columns should be identified as the explicit object that is referenced. DayPlanEvent.action:identifier Data Element" DEFVAL {null} ::= { timeBaseDayPlanEntry 5 } dayPlanStatus OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the current value of the active day PlanNumber-object. A value of zero (0) indicates that there is no dayPlanNumber that is currently active. DayPlanTable.activeDayPlan:identifier Data Element" ::= { timebase 6 } -- This object has been deprecated. See Clause B.2 for more information. globalLocalTimeDifferential OBJECT-TYPE SYNTAX INTEGER (-43200..43200) ACCESS read-write STATUS deprecated DESCRIPTION "Indicates the number of seconds offset between local time and GMT. Positive values indicate local times in the Eastern Hemisphere up to the International Date Line and negative values indicate local times in the Western Hemisphere back to the International Date Line. If one of the daylight savings times is activated, this value will change automatically at the referenced time. For example, Central Standard Time (CST) is -21600 and Central Daylight Time (CDT) is -18000." ::= { globalTimeManagement 4 } controllerStandardTimeZone OBJECT-TYPE SYNTAX INTEGER (-43200..43200) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the number of seconds offset between local Standard Time and GMT. Positive values indicate local times in the Eastern Hemisphere up to the International Date Line and negative values indicate local times in the Western Hemisphere back to the International Date Line. This value does not change in response to a daylight savings time event. Controller.standardTimeZone:quantity Data Element second" DEFVAL {0} ::= { globalTimeManagement 5 } controllerLocalTime OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " The current local time expressed in seconds since 00:00:00 (midnight) January 1, 1970 of the same time offset. This value changes by 3600 seconds in response to a daylight savings time event. Controller.localTime:quantity second Data Element" ::= { globalTimeManagement 6 } NOTE—These objects will be moved to a future version of NTCIP 1103. globalReport OBJECT IDENTIFIER ::= { global 4 } -- This node is an identifier used to organize all objects for support of report functions -- that are common to most device types. -- NOTE—The event class table is presented first in order to ease the -- readability of the standard; however, the node numbers assigned to this -- table reflect the original node numbering used in the original 1996 -- specification in order to preserve backwards compatibility with existing -- systems. maxEventClasses OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The object defines the number of rows in the eventClassTable that this device supports. This is a static table. EventClassTable.maxEventClasses:quantity Data Element EventClass" ::= { globalReport 5 } eventClassTable OBJECT-TYPE SYNTAX SEQUENCE OF EventClassEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table is used to configure event logging limits and log table maintenance. EventClassTable Entity Type static" ::= { globalReport 6 } eventClassEntry OBJECT-TYPE SYNTAX EventClassEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This defines a row in the Event Class Table EventClass Entity Type" INDEX { eventClassNumber } ::= { eventClassTable 1 } EventClassEntry ::= SEQUENCE { eventClassNumber INTEGER, eventClassLimit INTEGER, eventClassClearTime Counter, eventClassDescription OCTET STRING, eventClassNumRowsInLog INTEGER, eventClassNumEvents INTEGER } eventClassNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "This is a class value that is to be configured. EventClass.number:identifier Data Element" ::= { eventClassEntry 1 } eventClassLimit OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the maximum number of events of the associated class to store in the log. Once the limit is reached, the oldest entry of the matching class will be overwritten by any new entry of the same class. If the value of this object is set to a number smaller than the current number of rows within this class in the eventLogTable, then the oldest entries shall be lost/deleted. The sum of all event class limits shall not exceed the maxEventLogSize object; if a SET operation to this object causes the sum of eventClassLimit objects to exceed maxEventLogSize, then the agent shall respond with a genErr. EventClass.eventLimit:quantity Data Element Event" ::= { eventClassEntry 2 } eventClassClearTime OBJECT-TYPE SYNTAX Counter ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to clear multiple event log entries from the eventLogTable. All events of this class that have an eventLogTime equal to or less than this object shall be cleared from the eventLogTable. If this object has a value greater than the current value of globalTime, it shall prevent the logging of any events of this class. EventClass.clearTime:quantity Data Element second" DEFVAL {0} ::= { eventClassEntry 3 } eventClassDescription OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies a description of the class in ASCII characters. EventClass.description:text Data Element" ::= { eventClassEntry 4 } eventClassNumRowsInLog OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "The number of rows for this class that currently exist in the eventLogTable. EventClass.currentEntries:quantity Data Element Event" ::= { eventClassEntry 5 } eventClassNumEvents OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION " This object is a counter that gets incremented every time an event occurs for this class; it shall initialize to zero at power up. The value shall roll over each time it exceeds the maximum of 65535. This value shall not be affected by logic related to the eventClassLimit or eventClassClearTime objects. EventClass.eventCounter:quantity Data Element Events" ::= { eventClassEntry 6 } maxEventLogConfigs OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The number of rows that exist in the static eventLogConfig table for this device. EventTypeTable.maxEventTypes:quantity Data Element EventType" ::= { globalReport 1} eventLogConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF EventLogConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing Event Log Configuration information. The number of rows in this table is equal to the maxEventLogConfigs object. This table defines the parameters that the device will monitor to create an event. EventTypeTable Entity Type static" ::= { globalReport 2 } eventLogConfigEntry OBJECT-TYPE SYNTAX EventLogConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This object defines an entry in the event log configuration table. EventType Entity Type" INDEX { eventConfigID } ::= { eventLogConfigTable 1 } EventLogConfigEntry ::= SEQUENCE { eventConfigID INTEGER, eventConfigClass INTEGER, eventConfigMode INTEGER, eventConfigCompareValue INTEGER, eventConfigCompareValue2 INTEGER, eventConfigCompareOID OBJECT IDENTIFIER, eventConfigLogOID OBJECT IDENTIFIER, eventConfigAction INTEGER, eventConfigStatus INTEGER } eventConfigID OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This object contains the row number which is used to identify the event associated with this row in the eventLogConfigTable. The number of event IDs shall not exceed the value indicated in the maxEventLogConfigs object. EventType.identifier:identifier Data Element" ::= { eventLogConfigEntry 1 } eventConfigClass OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "This object contains the class value to assign to the event associated with this row in the event configuration table. This value is used in the event log table to organize various events defined in this table into logical groupings. This value shall not exceed the maxEventClasses object value. NOTE1—See NTCIP 1103 for additional requirements related to traps. NOTE2—The event cannot be logged if the EventClass has an eventClassLimit of zero (0), EventType.class:identifier Data Element " DEFVAL {1} ::= { eventLogConfigEntry 2 } eventConfigMode OBJECT-TYPE SYNTAX INTEGER { other (1), onChange (2), greaterThanValue (3), smallerThanValue (4), hysteresisBound (5), periodic (6), andedWithValue (7) } ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the mode of operation for this event. The modes are defined as follows: Value Description other the event mode of operation is not described in this standard, refer to the device manual. onChange create a log entry when the object value referenced by eventConfigCompareOID changes. The values of eventConfigCompareValue and eventConfigCompareValue2 are ignored in this mode. greaterThanValue create a log entry when the object value referenced by eventConfigCompareOID becomes greater than the value of eventConfigCompareValue for the time (tenth seconds) defined by eventConfigCompareValue2 (zero means immediate logging). smallerThanValue create a log entry when the object value referenced by eventConfigCompareOID becomes less than the value of eventConfigCompareValue for the time (tenth seconds) defined by eventConfigCompareValue2 (zero means immediate logging). hysteresisBound create a log entry when the object value referenced by eventConfigCompareOID becomes less than or greater than the bound values. The lowerbound value is the lower value of eventConfigCompareValue and eventConfigCompareValue2; the upperbound value is the higher value of the two values. When the object value becomes greater than the upper bound value, subsequent logging of upperbound conditions shall not occur until the object value becomes less than the lower bound value. When the object value becomes less than the lower bound value, subsequent logging of lowerbound conditions shall not occur until the object value becomes greater than the upper bound value. periodic create a log entry every x seconds, where x is defined by the value stored in eventConfigCompareValue. The values stored in eventConfigCompareValue2 and eventConfigCompareOID are ignored in this mode. andedWithValue create a log entry when the object value referenced by eventConfigCompareOID ANDED with the value of eventConfigCompareValue is NOT equal to zero for the time (tenth seconds) defined by eventConfigCompareValue2 (zero means immediate logging). This allows monitoring of a specific bit; the condition becomes true anytime that any one of the selected bits become true. EventType.mode:code Data Element" DEFVAL {onChange} ::= { eventLogConfigEntry 3 } eventConfigCompareValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This object contains the comparision value to use with eventConfigMode values (greaterThanValue, smallerThanValue, hysteresisBound ). No value within this object is necessary when the eventConfigMode-object has the value onChange (2). EventType.compareValue:number Data Element" DEFVAL {0} ::= { eventLogConfigEntry 4 } eventConfigCompareValue2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "If the eventConfigMode is set to hysteresisBound, this object specifies the second comparison value for the hysteresis. If the eventConfigMode is set to greaterThanValue or smallerThanValue, this object specifies the time (in tenth of seconds) for which the comparison must be true prior to the event condition becoming true (the value shall be reported in tenths of seconds, per the original specification, but the accurracy shall be plus/minus one second due to implementation experience). If the eventConfigMode is set to onChange or periodic, the value of this object shall be ignored. EventType.compareValue2:number Data Element" DEFVAL {0} ::= { eventLogConfigEntry 5 } eventConfigCompareOID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-write STATUS mandatory DESCRIPTION "This object contains the object identifier which references the value against which the comparison is made. If the eventConfigMode is set to periodic, the value of this object shall be ignored. If the eventConfigMode is set to greaterThanValue, smallerThanValue or hysteresisBound, this object must reference an object whose SYNTAX resolves to a ranged or unranged INTEGER. As with all other objects that are sub-ranged by a given implementation, an agent should return a badValue error if it receives a set command indicating a OID which is not supported by the implementation or which is not null. EventType.compareObject:identifier Data Element" DEFVAL {null} ::= { eventLogConfigEntry 6 } eventConfigLogOID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-write STATUS mandatory DESCRIPTION "This object contains the object identifier which indicates what value to log when a condition or event occurs (e.g., log the phase display when the watchdog alarm status changes). As with all other objects that are sub-ranged by a given implementation, an agent should return a badValue error if it receives a set command indicating a value which is not supported by the implementation. The valid value range of this object shall not include any values, other than null, that do not correspond to objects that may exist within the agent, although it may be further restricted. The valid value range of this object shall not include objects under the following nodes: Security - { nema transportation devices global security } CHAP - { nema transportation protocols layers chap } EventType.logObject:identifier Data Element" DEFVAL {null} ::= { eventLogConfigEntry 7 } eventConfigAction OBJECT-TYPE SYNTAX INTEGER { other (1), disabled (2), log (3) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object indicates what action shall take place when this event occurs. disabled - no entry will be recorded due to this event. log - an entry will be recorded in the event log table when this event occurs. NOTE—See NTCIP 1103 for additional requirements related to traps. EventType.action:code Data Element" DEFVAL {disabled} ::= { eventLogConfigEntry 8 } eventConfigStatus OBJECT-TYPE SYNTAX INTEGER { other (1), disabled (2), log (3), error (4) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object indicates the current status of the configured event. Upon setting any object in this row of the eventLogConfigTable, the agent will determine if the setting is valid and will set this object to one of the following states: other indicates that the action is successfully set to a mode other than that defined in this standard disabled indicates that the action is set to disabled log indicates that the action is successfully set to the log state after passing consistency checks. error indicates that the requested action could not be implemented due to a consistency check EventType.status:code Data Element" ::= { eventLogConfigEntry 9 } maxEventLogSize OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The maximum, fixed number of rows that can be utilized within the eventLogTable. EventTable.maxEventLogSize:quantity Data Element Event" ::= { globalReport 3} eventLogTable OBJECT-TYPE SYNTAX SEQUENCE OF EventLogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing Event History data collected. A request for an object from a row that has not been instantiated or has been cleared shall return a noSuchName error. EventTable Entity Type dynamic status" ::= { globalReport 4 } eventLogEntry OBJECT-TYPE SYNTAX EventLogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This object defines an entry in the event log table Event Entity Type" INDEX { eventLogClass, eventLogNumber } ::= { eventLogTable 1 } EventLogEntry ::= SEQUENCE { eventLogClass INTEGER, eventLogNumber INTEGER, eventLogID INTEGER, eventLogTime Counter, eventLogValue Opaque } eventLogClass OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "This object contains the class of the associated event as defined in the eventLogConfig Table. ClassLog.class:identifier Data Element" ::= { eventLogEntry 1 } eventLogNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "The event number within this class for this event. Event numbers shall be assigned starting at 1 and shall increase to the value specified by the associated eventClassLimit for the class associated with the rows. Events shall maintain a chronological ordering in the table with the oldest event of a class occupying the row with eventNumber = 1, and subsequent events filling subsequent rows. This ordering shall be maintained for those rows still remaining when events are cleared. Event.number:identifier Data Element" ::= { eventLogEntry 2 } eventLogID OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This object contains the event configuration ID (from the eventLogConfigTable) that caused this table entry. It indicates the row in the eventLogConfig table reponsible for this event entry. Event.type:identifier Data Element" ::= { eventLogEntry 3 } eventLogTime OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The time that the event was detected. If the device supports the globalTime object, the value shall reflect the value of globalTime when the event occurred, otherwise this shall be the time in seconds since the device powered up. The event shall be detected and timestamped within one second from the event becoming true. The event shall be logged in the table within five seconds of the event being detected. These timing resolutions may be modified by a device profile. Event.logTime:quantity Data Element second" ::= { eventLogEntry 4 } eventLogValue OBJECT-TYPE SYNTAX Opaque ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is set to the BER encoding of the value referenced by the eventConfigLogOID of the associated eventLogID when the event was logged. Its length is variable. The value shall not contain any padding characters either before or after the values. NOTE—Opaque objects are doubly wrapped. For SNMP operations, which use BER, this would be {type, length, {type, length, value}}. For example, a zero-length octet string, would be encoded in BER as 0x44 02 04 00. For STMP or SFMP operations, which use OER, this would be { length, {type, length, value}}. For example, the same example would be encoded in OER as 0x02 04 00. Event.logValue:frame Data Element" ::= { eventLogEntry 5 } numEvents OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION " This object is a counter that gets incremented every time an event occurs and shall initialize to zero at power up. The value shall roll over each time it exceeds the maximum of 65535. This value shall not be affected by logic related to the eventClassLimit or eventClassClearTime objects. EventTable.numEvents:quantity Data Element Events" ::= { globalReport 7 } -- NOTE: In the future, these objects will be moved to NTCIP 2101. profilesPMPP OBJECT IDENTIFIER ::= { profiles 3 } -- This node is an identifier used to group all objects for support of the PMPP function that -- are common to all device types. The objects under this node are placed under the -- Protocols\Profiles\PMPP subtree within the NEMA node, but they have been listed here due to the lack -- of a separate document that lists these objects. maxGroupAddresses OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of group addresses this device supports. This object indicates the maximum number of rows in the hdlcGroupAddressTable. Secondary.maxGroupAddresses:quantity Data Element address" ::= {profilesPMPP 1 } hdlcGroupAddressTable OBJECT-TYPE SYNTAX SEQUENCE OF HdlcGroupAddressEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table containing group addresses at which a device may receive frames. HdlcGroupAddressTable Entity Type static" ::= { profilesPMPP 2 } hdlcGroupAddressEntry OBJECT-TYPE SYNTAX HdlcGroupAddressEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " An entry in the group address table that contains a device’s data link layer group address at which it will accept frames. HdlcGroupAddress Entity Type" INDEX { hdlcGroupAddressIndex } ::= { hdlcGroupAddressTable 1 } HdlcGroupAddressEntry ::= SEQUENCE { hdlcGroupAddressIndex INTEGER, hdlcGroupAddress INTEGER, -- deprecated hdlcGroupAddressNumber INTEGER } hdlcGroupAddressIndex OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "The index number for the group address in this row. GroupAddress.index:identifier Data Element" ::= { hdlcGroupAddressEntry 1} -- This object has been deprecated. See Clause B.3 for more information. hdlcGroupAddress OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS deprecated DESCRIPTION "A group address for the data link layer. For PMPP, the syntax is an 8 or 16 bit entry with the second low order bit set to a one indicating that this is a group address." REFERENCE "NEMA TS 3.3 Clause 3.3.3.1" ::= { hdlcGroupAddressEntry 2} hdlcGroupAddressNumber OBJECT-TYPE SYNTAX INTEGER (0..62) ACCESS read-write STATUS mandatory DESCRIPTION "A group address number prior to any encoding for the data link layer. The address of 63 is reserved for the all stations address. The value of zero (0) shall disable this row of the table. NOTE—In PMPP all group addresses are encoded in one byte. GroupAddress.address:number Data Element" REFERENCE "NTCIP 2101" DEFVAL { 0 } ::= { hdlcGroupAddressEntry 3} -- NOTE: In the future, these objects will be moved to NTCIP 1103. -- however, these objects are expected to remain under the global 5 node of the -- ISO tree. security OBJECT IDENTIFIER ::= {global 5} -- This node is an identifier used to group all objects related to the -- assignment of community names and the access rights they provide. communityNameAdmin OBJECT-TYPE SYNTAX OCTET STRING (SIZE(8..16)) ACCESS read-write STATUS mandatory DESCRIPTION "This object is the community name that must be used to specifically gain access to information under the security node. A message with this value in the community name field of an SNMP message has user read-write access to the security node objects and all other objects implemented in the device. The syntax is defined as an OCTET STRING and therefore any character can have a value of 0..255. CommunityNames.admin:text Data Element" DEFVAL { "administrator" } ::= { security 1 } communityNamesMax OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the maximum number of rows that are implemented in the community name table. CommunityNames.maximumNames:quantity Data Element" ::= { security 2 } communityNameTable OBJECT-TYPE SYNTAX SEQUENCE OF CommunityNameTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table defines the community names that can appear in the community name field of the SNMP message and access privileges associated with that community name. CommunityNameTable Entity Type Static" ::= { security 3 } communityNameTableEntry OBJECT-TYPE SYNTAX CommunityNameTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is the row index of information in the community name table. CommunityName Entity Type" INDEX { communityNameIndex } ::= { communityNameTable 1} CommunityNameTableEntry::=SEQUENCE { communityNameIndex INTEGER, communityNameUser OCTET STRING, communityNameAccessMask Gauge } communityNameIndex OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "This object defines the row index into the communityNameTable. This value shall not exceed the communityNamesMax object value. CommunityName.index:identifier Data Element" ::= { communityNameTableEntry 1 } communityNameUser OBJECT-TYPE SYNTAX OCTET STRING (SIZE(6..16)) ACCESS read-write STATUS mandatory DESCRIPTION "This object defines a community name value that a security administrator can assign user read-write access to information (other than security) in a device. A message with this value in the community name field of an SNMP/SFMP message has user access rights as defined in the communityNameAccessMask. The syntax is defined as an OCTET STRING and therefore any character can have a value of 0..255. CommunityName.user:text Data Element" DEFVAL { "public" } ::= { communityNameTableEntry 2 } communityNameAccessMask OBJECT-TYPE SYNTAX Gauge ACCESS read-write STATUS mandatory DESCRIPTION "This object defines a 32 bit mask that can be used to associate 'write access' with a community name. A value of 0x00 00 00 00 grants the community name user read-only access and overrides any individual object's read-write access clause. A value of 0xFF FF FF FF grants the community name user read-write access and an individual object's read-write access clause applies. Values other than 0x00 00 00 00 and 0xFF FF FF FF are implementation specific and may limit viewing and/or accessing the information in a device. CommunityName.accessMask:code Data Element" DEFVAL { 4294967295 } ::= { communityNameTableEntry 3 } auxIO OBJECT IDENTIFIER ::= { global 7} -- This node is an identifier used to group all objects supporting auxiliary I/O functions -- NOTE: These objects were formerly located under the experimental node. auxIOTableNumDigitalPorts OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "The number of rows contained in the ‘auxIOTable’ with the auxPortType set to ‘digital’. AuxIOTable.maxDigitalPorts:quantity Data Element port" ::= {auxIO 1} auxIOTableNumAnalogPorts OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "The number of rows contained in the ‘auxIOTable’ with the auxPortType set to ‘analog’. AuxIOTable.maxAnalogPorts:quantity Data Element port" ::= {auxIO 2} auxIOTable OBJECT-TYPE SYNTAX SEQUENCE OF AuxIOEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table providing the means to access any non- mission-critical or safety-related auxiliary I/O of the Controller, this includes reading inputs and setting outputs. A maximum of 255 auxiliary IOs can be defined for all, digital, analog or other types of ports. This table shall not be used to control or monitor any safety related equipment. The user should be aware that the electrical levels used by the ports are not standardized by these objects; such information should be contained in the hardware manual. AuxIOTable Entity Type static" ::= { auxIO 3} auxIOEntry OBJECT-TYPE SYNTAX AuxIOEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Parameters of the auxiliary I/O table. AuxIOPort Entity Type" INDEX {auxIOPortType, auxIOPortNumber} ::={auxIOTable 1} AuxIOEntry ::= SEQUENCE { auxIOPortType INTEGER, auxIOPortNumber INTEGER, auxIOPortDescription DisplayString, auxIOPortResolution INTEGER, auxIOPortValue INTEGER, auxIOPortDirection INTEGER, auxIOPortLastCommandedState INTEGER } auxIOPortType OBJECT-TYPE SYNTAX INTEGER{ other (1), analog (2), digital (3) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the type of auxiliary I/O, which can be analog, digital or other. AuxIOPort.type:code Data Element" ::= {auxIOEntry 1} auxIOPortNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the port number for the associated port type. Port numbers are used sequentially from one to max for each port type. There can be a port 1 for analog port and port 1 for digital port. AuxIOPort.number:identifier Data Element" ::= {auxIOEntry 2} auxIOPortDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "Informational text field describing the device at the associated auxiliary I/O AuxIOPort.description:text Data Element" ::= {auxIOEntry 3} auxIOPortResolution OBJECT-TYPE SYNTAX INTEGER (1..32) ACCESS read-only STATUS mandatory DESCRIPTION "Defines number of bits used for the IO-port (e.g. width of digital, resolution of analog). Thus, this feature allows the digital monitoring (via NTCIP) of an analog port on the agent. AuxIOPort.resolution:quantity Data Element bit" ::= {auxIOEntry 4} auxIOPortValue OBJECT-TYPE SYNTAX INTEGER (0..4294967295) ACCESS read-write STATUS mandatory DESCRIPTION "For input or bidirectional ports, this contains the current value of the input. For output ports, this is the last commanded value of the port. A genError shall be generated, if this object is set and the port is an input. The actual value exchanged shall not exceed [2^(auxIOPortResolution) – 1]; any SET operation to a value in excess of this number shall result in a genErr and any GET response in excess of this value shall be considered erroneous. AuxIOPort.value:number Data Element" ::= {auxIOEntry 5} auxIOPortDirection OBJECT-TYPE SYNTAX INTEGER { output (1), input (2), bidirectional (3)} ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether state of this port can be set (output), read (input) or both (bidirectional). AuxIOPort.direction:code Data Element" ::= {auxIOEntry 6} auxIOPortLastCommandedState OBJECT-TYPE SYNTAX INTEGER (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "For bi-directional ports, this object shall indicate the last state to which the auxIOPortValue object was set. For output ports, this value shall always be equal to the auxIOPortValue object. For input ports, this value shall always be zero (0). AuxIOPort.lastCommandedState:number Data Element" ::= {auxIOEntry 7} END