-- OIDref derived MIB transcription. Original PDF: https://www.ntcip.org/file/2018/11/NTCIP1103v0127r-1.pdf -- Publisher front matter and notices follow as comments. -- A Joint Standard of AASHTO, ITE, and NEMA -- -- -- -- -- NTCIP 1103 version v01 -- -- National Transportation -- Communications for ITS Protocol -- -- Transportation Management -- Protocols -- -- published in January 2009 -- -- This Adobe® PDF copy of an NTCIP standard is available at no-cost for a limited time -- through support from the U.S. DOT / Research and Innovative Technology -- Administration, whose assistance is gratefully acknowledged. -- -- -- -- -- Published by -- -- American Association of State Highway and Transportation Officials (AASHTO) -- 444 North Capitol Street, N.W., Suite 249 -- Washington, D.C. 20001 -- -- Institute of Transportation Engineers (ITE) -- 1099 14th Street, N.W., Suite 300 West -- Washington, D.C. 20005-3438 -- -- National Electrical Manufacturers Association (NEMA) -- 1300 North 17th Street, Suite 1752 -- Rosslyn, Virginia 22209-3806 -- -- -- -- file version 1103 v01.27r rita -- © 2008 AASHTO / ITE / NEMA. All rights reserved. -- -- NOTICES -- -- Copyright Notice -- -- © 2008 by the American Association of State Highway and Transportation Officials (AASHTO), the -- Institute of Transportation Engineers (ITE), and the National Electrical Manufacturers Association -- (NEMA). All intellectual property rights, including, but not limited to, the rights of reproduction, translation -- and display are reserved under the laws of the United States of America, the Universal Copyright -- Convention, the Berne Convention, and the International and Pan American Copyright Conventions. -- Except as licensed or permitted, you may not copy these materials without prior written permission from -- AASHTO, ITE, or NEMA. Use of these materials does not give you any rights of ownership or claim of -- copyright in or to these materials. -- -- Visit www.ntcip.org for other copyright information, for instructions to request reprints of excerpts, and to -- request reproduction that is not granted below. -- -- -- PDF File License Agreement -- -- To the extent that these materials are distributed by AASHTO / ITE / NEMA in the form of an Adobe® -- Portable Document Format (PDF) electronic data file (the “PDF file”), AASHTO / ITE / NEMA authorizes -- each registered PDF file user to view, download, copy, or print the PDF file available from the authorized -- Web site, subject to the terms and conditions of this license agreement: -- -- (a) you may download one copy of each PDF file for personal, noncommercial, and intraorganizational -- use only; -- (b) ownership of the PDF file is not transferred to you; you are licensed to use the PDF file; -- (c) you may make one more electronic copy of the PDF file, such as to a second hard drive or burn to a -- CD; -- (d) you agree not to copy, distribute, or transfer the PDF file from that media to any other electronic media -- or device; -- (e) you may print one paper copy of the PDF file; -- (f) you may make one paper reproduction of the printed copy; -- (g) any permitted copies of the PDF file must retain the copyright notice, and any other proprietary notices -- contained in the file; -- (h) the PDF file license does not include (1) resale of the PDF file or copies, (2) republishing the content -- in compendiums or anthologies, (3) publishing excerpts in commercial publications or works for hire, -- (4) editing or modification of the PDF file except those portions as permitted, (5) posting on network -- servers or distribution by electronic mail or from electronic storage devices, and (6) translation to other -- languages or conversion to other electronic formats; -- (i) other use of the PDF file and printed copy requires express, prior written consent. -- -- The information in this publication was considered technically sound by the consensus of persons -- engaged in the development and approval of the document at the time it was developed. Consensus -- does not necessarily mean that there is unanimous agreement among every person participating in the -- development of this document. -- -- AASHTO, ITE, and NEMA standards and guideline publications, of which the document contained herein -- is one, are developed through a voluntary consensus standards development process. This process -- brings together volunteers and seeks out the views of persons who have an interest in the topic covered -- by this publication. While AASHTO, ITE, and NEMA administer the process and establish rules to -- promote fairness in the development of consensus, they do not write the document and they do not -- independently test, evaluate, or verify the accuracy or completeness of any information or the soundness -- of any judgments contained in their standards and guideline publications. -- -- -- -- -- Do Not Copy Without Written Permission © 2008 AASHTO / ITE / NEMA -- -- AASHTO, ITE, and NEMA disclaim liability for any personal injury, property, or other damages of any -- nature whatsoever, whether special, indirect, consequential, or compensatory, directly or indirectly -- resulting from the publication, use of, application, or reliance on this document. AASHTO, ITE, and NEMA -- disclaim and make no guaranty or warranty, express or implied, as to the accuracy or completeness of -- any information published herein, and disclaims and makes no warranty that the information in this -- document will fulfill any of your particular purposes or needs. AASHTO, ITE, and NEMA do not undertake -- to guarantee the performance of any individual manufacturer or seller’s products or services by virtue of -- this standard or guide. -- -- In publishing and making this document available, AASHTO, ITE, and NEMA are not undertaking to -- render professional or other services for or on behalf of any person or entity, nor are AASHTO, ITE, and -- NEMA undertaking to perform any duty owed by any person or entity to someone else. Anyone using this -- document should rely on his or her own independent judgment or, as appropriate, seek the advice of a -- competent professional in determining the exercise of reasonable care in any given circumstances. -- Information and other standards on the topic covered by this publication may be available from other -- sources, which the user may wish to consult for additional views or information not covered by this -- publication. -- -- AASHTO, ITE, and NEMA have no power, nor do they undertake to police or enforce compliance with the -- contents of this document. AASHTO, ITE, and NEMA do not certify, test, or inspect products, designs, or -- installations for safety or health purposes. Any certification or other statement of compliance with any -- health or safety-related information in this document shall not be attributable to AASHTO, ITE, or NEMA -- and is solely the responsibility of the certifier or maker of the statement. -- -- -- Data Dictionary and MIB Distribution Permission -- -- To the extent that these materials are distributed by AASHTO / ITE / NEMA in the form of a Data -- Dictionary (“DD”) or Management Information Base (“MIB”), AASHTO / ITE / NEMA extend the following -- permission: -- -- You may make and/or distribute unlimited copies, including derivative works, of the DD or MIB, including -- copies for commercial distribution, provided that: -- (i) each copy you make and/or distribute contains the citation “Derived from NTCIP 0000 [insert the -- standard number]. Used by permission of AASHTO / ITE / NEMA.”; -- (ii) the copies or derivative works are not made part of the standards publications or works offered by -- other standards developing organizations or publishers or as works-for-hire not associated with -- commercial hardware or software products intended for field implementation; -- (iii) use of the DD or MIB is restricted in that the syntax fields may be modified only to reflect a more -- restrictive subrange or enumerated values; -- (iv) the description field may be modified but only to the extent that: (a) only those bit values or -- enumerated values that are supported are listed; and (b) the more restrictive subrange is expressed. -- -- These materials are delivered “AS IS” without any warranties as to their use or performance. -- -- AASHTO / ITE / NEMA and their suppliers do not warrant the performance or results you may -- obtain by using these materials. AASHTO / ITE / NEMA and their suppliers make no warranties, -- express or implied, as to noninfringement of third party rights, merchantability, or fitness for any -- particular purpose. In no event will AASHTO / ITE / NEMA or their suppliers be liable to you or any -- third party for any claim or for any consequential, incidental or special damages, including any -- lost profits or lost savings, arising from your reproduction or use of these materials, even if an -- AASHTO / ITE / NEMA representative has been advised of the possibility of such damages. -- -- Some states or jurisdictions do not allow the exclusion or limitation of incidental, consequential or special -- damages, or the exclusion of implied warranties, so the above limitations may not apply to you. -- -- -- -- © 2008 AASHTO / ITE / NEMA Do Not Copy Without Written Permission -- -- Use of these materials does not constitute an endorsement or affiliation by or between AASHTO, ITE, or -- NEMA and you, your company, or your products and services. -- -- If you are unwilling to accept the foregoing restrictions, you should immediately return these materials. -- -- -- PRL and RTM Distribution Permission -- -- To the extent that these materials are distributed by AASHTO / ITE / NEMA in the form of a Profile -- Requirements List (“PRL”) or a Requirements Traceability Matrix (“RTM”), AASHTO / ITE / NEMA extend -- the following permission: -- -- (i) you may make and/or distribute unlimited copies, including derivative works of the PRL (then known as -- a Profile Implementation Conformance Statement (“PICS”)) or the RTM, provided that each copy you -- make and/or distribute contains the citation “Based on NTCIP 0000 [insert the standard number] PRL or -- RTM. Used by permission. Original text (C) AASHTO / ITE / NEMA.”; -- (ii) you may not modify the PRL or the RTM except for the Project Requirements column, which is the -- only column that may be modified to show a products’ implementation or the project-specific -- requirements; and -- (iii) if the PRL or RTM excerpt is made from an unapproved draft, add to the citation “PRL (or RTM) -- excerpted from a draft document containing preliminary information that is subject to change.” -- -- The permission is limited to not include reuse in works offered by other standards developing -- organizations or publishers, and to not include reuse in works-for-hire or compendiums or electronic -- storage that are not associated with commercial hardware or software products intended for field -- installation. -- -- A PICS is a Profile Requirements List which is completed to indicate the features that are supported in an -- implementation. Visit www.ntcip.org for information on electronic copies of the MIBs, PRLs, and RTMs. -- -- -- Content and Liability Disclaimer -- -- The information in this publication was considered technically sound by the consensus of persons -- engaged in the development and approval of the document at the time it was developed. Consensus -- does not necessarily mean that there is unanimous agreement among every person participating in the -- development of this document. -- -- AASHTO, ITE, and NEMA standards and guideline publications, of which the document contained herein -- is one, are developed through a voluntary consensus standards development process. This process -- brings together volunteers and/or seeks out the views of persons who have an interest in the topic -- covered by this publication. While AASHTO, ITE, and NEMA administer the process and establish rules -- to promote fairness in the development of consensus, they do not write the document and they do not -- independently test, evaluate, or verify the accuracy or completeness of any information or the soundness -- of any judgments contained in their standards and guideline publications. -- -- AASHTO, ITE, and NEMA disclaim liability for any personal injury, property, or other damages of any -- nature whatsoever, whether special, indirect, consequential, or compensatory, directly or indirectly -- resulting from the publication, use of, application, or reliance on this document. AASHTO, ITE, and NEMA -- disclaim and make no guaranty or warranty, express or implied, as to the accuracy or completeness of -- any information published herein, and disclaims and makes no warranty that the information in this -- document will fulfill any of your particular purposes or needs. AASHTO, ITE, and NEMA do not undertake -- to guarantee the performance of any individual manufacturer or seller’s products or services by virtue of -- this standard or guide. -- -- In publishing and making this document available, AASHTO, ITE, and NEMA are not undertaking to -- -- -- Do Not Copy Without Written Permission © 2008 AASHTO / ITE / NEMA -- -- render professional or other services for or on behalf of any person or entity, nor are AASHTO, ITE, and -- NEMA undertaking to perform any duty owed by any person or entity to someone else. Anyone using this -- document should rely on his or her own independent judgment or, as appropriate, seek the advice of a -- competent professional in determining the exercise of reasonable care in any given circumstances. -- Information and other standards on the topic covered by this publication may be available from other -- sources, which the user may wish to consult for additional views or information not covered by this -- publication. -- -- AASHTO, ITE, and NEMA have no power, nor do they undertake to police or enforce compliance with the -- contents of this document. AASHTO, ITE, and NEMA do not certify, test, or inspect products, designs, or -- installations for safety or health purposes. Any certification or other statement of compliance with any -- health or safety-related information in this document shall not be attributable to AASHTO, ITE, or NEMA -- and is solely the responsibility of the certifier or maker of the statement. -- -- -- Trademark Notice -- -- NTCIP is a trademark of AASHTO / ITE / NEMA. All other marks mentioned in this standard are the -- trademarks of their respective owners. -- -- -- -- -- © 2008 AASHTO / ITE / NEMA Do Not Copy Without Written Permission -- -- < This page is intentionally left blank. > -- -- -- -- -- Do Not Copy Without Written Permission © 2008 AASHTO / ITE / NEMA -- -- NTCIP 1103 v01.27 -- Page i -- -- -- ACKNOWLEDGEMENTS -- -- NTCIP 1103 v01 was prepared by the NTCIP Base Standards and Profiles Working Group (BSP2 WG), -- which is a subdivision of the Joint Committee on the NTCIP. The Joint Committee is organized under a -- Memorandum of Understanding among the American Association of State Highway and Transportation -- Officials (AASHTO), the Institute of Transportation Engineers (ITE), and the National Electrical -- Manufacturers Association (NEMA). The Joint Committee on the NTCIP consists of six representatives -- from each of the standards organizations, and provides guidance for NTCIP development. -- -- At the time that NTCIP 1103 v01 was prepared, the following individuals were active members of NTCIP -- BSP WG: -- -- • Robert DeRoche (Chair) • Nu Rosenbohm -- • Bud Kent • Ken Vaughn -- • Alex Mousadi -- -- Other individuals providing input to NTCIP 1103 v01 include: -- -- • Blake Christie • Bob Force -- • Michael Forbis • Gary Meredith -- -- In addition to the many volunteer efforts, recognition is also given to those organizations who supported -- the efforts of BSP2 WG by providing comments and funding, including: -- -- • CalTrans • Texas Department of Transportation -- • Econolite • Trevilon Corporation -- • Iteris, Inc. • Transcore -- • Mastek • U.S. Department of Transportation, -- • Ministry of Transportation Ontario Research and Innovative Technology -- • Mitretek Administration -- • PB Farradyne Inc. • Washington State Department of -- • PEEK Traffic Transportation -- • Robert DeRoche Consulting -- • Siemens ITS -- • Southwest Research Institute -- -- -- -- -- © 2008 AASHTO / ITE / NEMA Do Not Copy Without Written Permission -- -- NTCIP 1103 v01.27 -- Page ii -- -- -- -- -- < This page is intentionally left blank. > -- -- -- -- -- Do Not Copy Without Written Permission © 2008 AASHTO / ITE / NEMA NTCIP1103v0127 DEFINITIONS ::= BEGIN IMPORTS Gauge, Counter, NetworkAddress, Opaque, null FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 DisplayString FROM RFC1213-MIB OwnerString, RowStatusStatic, dynObjMgmt, profiles, application, global, OerString FROM NTCIP8004-A-2004; -- EXPORTS EVERYTHING A.2. Type Definitions ConfigEntryStatus ::= INTEGER { valid (1), underCreation (2), invalid (3) } -- See NTCIP 1103 v01 Section 5.2.4.1 for the complete definition of this Type. A.3. Objects for SNMP snmpConfig OBJECT IDENTIFIER ::= {application 1} A.3.1. Maximum SNMP Packet Size Parameter snmp-maxPacketSize OBJECT-TYPE SYNTAX INTEGER (484..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the maximum packet size, in octets, that the SNMP agent supports for reception or transmission." ::= {snmpConfig 1} A.4. Objects for SFMP sfmp OBJECT IDENTIFIER ::= {application 2} sfmpStatistics OBJECT IDENTIFIER ::= { sfmp 1 } A.4.1. Number of Incoming SFMP Packets sfmp-inPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of Messages delivered to the SFMP entity for processing ." ::= { sfmpStatistics 1 } A.4.2. Number of Outgoing SFMP Packets sfmp-outPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SFMP PDU's which were generated by the SFMP protocol entity ." ::= { sfmpStatistics 2 } A.4.3. Number of Incoming SFMP Packets with Bad Version Numbers sfmp-inBadVersions OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SFMP Messages which were delivered to the SFMP protocol entity and were for an unsupported SFMP version." ::= { sfmpStatistics 3 } A.4.4. Number of Incoming SFMP Packets with Bad Community Names sfmp-inBadCommunityNames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SFMP Messages delivered to the SFMP protocol entity which used a SFMP community name not known to said entity." ::= { sfmpStatistics 4 } A.4.5. Number of Incoming SFMP Packets with Bad Use of a Community Name sfmp-inBadCommunityUses OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SFMP Messages delivered to the SFMP protocol entity which represented an SFMP operation which was not allowed by the SFMP community named in the Message." ::= { sfmpStatistics 5 } A.4.6. Number of Incoming SFMP Packets with Parsing Errors sfmp-inParseErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of OER errors encountered by the SFMP protocol entity when decoding received SFMP Messages." ::= { sfmpStatistics 6 } A.4.7. Reserved -- node 7 is reserved for bad types in order to parallel SNMP, but it does not -- apply to SFMP A.4.8. Number of Incoming SFMP Packets indicating a Too Big Error sfmp-inTooBigs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SFMP PDUs which were delivered to the SFMP protocol entity with a Message Type of Error and Error Number of tooBig." ::= { sfmpStatistics 8 } A.4.9. Number of Incoming SFMP Packets indicating a No Such Name Error sfmp-inNoSuchNames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SFMP PDUs which were delivered to the SFMP protocol entity with a Message Type of Error and Error Number of noSuchName." ::= { sfmpStatistics 9 } A.4.10. Number of Incoming SFMP Packets indicating a Bad Value Error sfmp-inBadValues OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SFMP PDUs which were delivered to the SFMP protocol entity with a Message Type of Error and Error Number of badValue." ::= { sfmpStatistics 10 } A.4.11. Number of Incoming SFMP Packets indicating a Read-Only Error sfmp-inReadOnlys OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SFMP PDUs which were delivered to the SFMP protocol entity with a Message Type of Error and Error Number of readOnly." ::= { sfmpStatistics 11 } A.4.12. Number of Incoming SFMP Packets indicating a General Error sfmp-inGenErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SFMP PDUs which were delivered to the SFMP protocol entity with a Message Type of Error and Error Number of genError." ::= { sfmpStatistics 12 } A.4.13. Reserved -- node 13 is reserved for total request vars in order to parallel SNMP, but it -- does not apply to SFMP A.4.14. Reserved -- node 14 is reserved for total set vars in order to parallel SNMP, but it does -- not apply to SFMP A.4.15. Number of Incoming SFMP Get Requests sfmp-inGetRequests OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SFMP Get-Request PDUs which have been accepted and processed by the SFMP protocol entity." ::= { sfmpStatistics 15 } A.4.16. Reserved -- node 16 is reserved for in get nexts in order to parallel SNMP, but it does -- not apply to SFMP A.4.17. Number of Incoming SFMP Set Requests sfmp-inSetRequests OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SFMP Set-Request PDUs which have been accepted and processed by the SFMP protocol entity." ::= { sfmpStatistics 17 } A.4.18. Number of Incoming SFMP Get Responses sfmp-inGetResponses OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SFMP Get-Response PDUs which have been accepted and processed by the SFMP protocol entity." ::= { sfmpStatistics 18 } A.4.19. Reserved -- node 19 is reserved for traps to parallel SNMP, but it -- does not apply to SFMP at present A.4.20. Number of Outgoing SFMP Packets indicating a Too Big Error sfmp-outTooBigs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SFMP PDUs which were generated by the SFMP protocol entity with a Message Type of Error and Error Number of tooBig." ::= { sfmpStatistics 20 } A.4.21. Number of Outgoing SFMP Packets indicating a No Such Name Error sfmp-outNoSuchNames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SFMP PDUs which were generated by the SFMP protocol entity with a Message Type of Error and Error Number of noSuchname." ::= { sfmpStatistics 21 } A.4.22. Number of Outgoing SFMP Packets indicating a Bad Value Error sfmp-outBadValues OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SFMP PDUs which were generated by the SFMP protocol entity with a Message Type of Error and Error Number of badValue." ::= { sfmpStatistics 22 } A.4.23. Number of Outgoing SFMP Packets indicating a Read-Only Error sfmp-outReadOnly OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SFMP PDUs which were generated by the SFMP protocol entity with a Message Type of Error and Error Number of readOnly." ::= { sfmpStatistics 23 } A.4.24. Number of Outgoing SFMP Packets indicating a General Error sfmp-outGenError OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SFMP PDUs which were generated by the SFMP protocol entity with a Message Type of Error and Error Number of genErr." ::= { sfmpStatistics 24 } A.4.25. Number of Outgoing SFMP Get Requests sfmp-outGetRequests OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SFMP PDU's with a Message Type of Get-Request, which have been generated by the SFMP protocol entity." ::= { sfmpStatistics 25 } A.4.26. Reserved -- node 26 is reserved for out get nexts in order to parallel SNMP, but it does -- not apply to SFMP A.4.27. Number of Outgoing SFMP Set Requests sfmp-outSetRequests OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SFMP PDU's with a Message Type of Set-Request, which have been generated by the SFMP protocol entity." ::= { sfmpStatistics 27 } A.4.28. Number of Outgoing SFMP Get Responses sfmp-outGetResponses OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SFMP PDU's with a Message Type of Get-Response, which have been generated by the SFMP protocol entity." ::= { sfmpStatistics 28 } A.4.29. Reserved -- node 29 is reserved for traps to parallel SNMP, but it -- does not apply to SFMP at present A.4.30. Reserved -- node 30 is reserved for enable authentication traps to parallel SNMP, but it -- does not apply to SFMP A.4.31. Number of Incoming SFMP Set Requests – No Replies sfmp-inSetRequestsNoReply OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SFMP Set-Request No Reply PDUs which have been accepted and processed by the SFMP protocol entity." ::= { sfmpStatistics 31 } A.4.32. Number of Incoming SFMP Set Responses sfmp-inSetResponses OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SFMP Set-Response PDUs which have been accepted and processed by the SFMP protocol entity." ::= { sfmpStatistics 32 } A.4.33. Number of Incoming SFMP Error Responses sfmp-inErrorResponses OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SFMP Error-Response PDUs which have been accepted and processed by the SFMP protocol entity." ::= { sfmpStatistics 33 } A.4.34. Number of Outgoing SFMP Set Requests – No Replies sfmp-outSetRequestsNoReply OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SFMP PDU's with a Message Type of Set-Request-No- Reply, which have been generated by the SFMP protocol entity." ::= { sfmpStatistics 34 } A.4.35. Number of Outgoing SFMP Set Responses sfmp-outSetResponses OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SFMP PDU's with a Message Type of Set-Response, which have been generated by the SFMP protocol entity." ::= { sfmpStatistics 35 } A.4.36. Number of Outgoing SFMP Error Responses sfmp-outErrorResponses OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SFMP PDU's with a Message Type of Error-Response, which have been generated by the SFMP protocol entity." ::= { sfmpStatistics 36 } A.5. Objects for STMP dynObjData OBJECT IDENTIFIER ::= { dynObjMgmt 2 } stmp OBJECT IDENTIFIER ::= { application 3 } A.5.1. Dynamic Object Definition Table dynObjDef OBJECT-TYPE SYNTAX SEQUENCE OF DynObjEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of objects to be included in dynamic objects" ::= { dynObjMgmt 1 } dynObjEntry OBJECT-TYPE SYNTAX DynObjEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of OBJECT IDENTIFIERs that make up a dynamic object" INDEX { dynObjNumber, dynObjIndex } ::= { dynObjDef 1 } DynObjEntry ::= SEQUENCE { dynObjNumber INTEGER (1..13), dynObjIndex INTEGER, dynObjVariable OBJECT IDENTIFIER } -- dynObjOwner & dynObjStatus were deprecated from the -- DynObjEntry structure. See Annex B. A.5.1.1. Dynamic Object Number dynObjNumber OBJECT-TYPE SYNTAX INTEGER ( 1..13) ACCESS read-only STATUS mandatory DESCRIPTION "The dynamic object number that this entry is to be associated with." ::= { dynObjEntry 1 } A.5.1.2. Dynamic Object Index dynObjIndex OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "An index that uniquely identifies an entry in the dynamic object table. Each entry defines an object that is to be associated with a dynamic object number. The dynObjIndex determines the order in which objects are transmitted for the associated dynamic object. The lower dynObjIndex numbers are transmitted before larger numbers for entries within the same dynamic object." ::= { dynObjEntry 2 } A.5.1.3. Dynamic Object Variable dynObjVariable OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-write STATUS mandatory DESCRIPTION "The complete object identifier of the particular variable to be included in the specified dynamic object number. Care must be taken when defining dynamic objects so that the maximum size of all the objects included in a dynamic object do not exceed the maximum packet size of the communications network. When set to reference a columnar object, an agent may wish to only validate the prefix portion of the object identifier. The suffix or index portion of an object identifier need not be instantiated or exist at the time a dynObjVariable is defined. This object shall not reference any of the objects identified in NTCIP 1103 v01 Section 8.2. This object may not be modified unless the associated dynObjConfigStatus object is equal to underCreation." DEFVAL {null} ::= { dynObjEntry 3 } A.5.1.4. Reserved -- { dynObjEntry 4 } is a deprecated node that was a columnar object of the DynObjEntry sequence. See Annex B. A.5.1.5. Reserved -- { dynObjEntry 5 } is a deprecated node that was a columnar object of the DynObjEntry sequence. See Annex B. A.5.2. Dynamic Object Data -- { dynObjData 1 } is deprecated. See Annex B. -- { dynObjData 2 } is deprecated. See Annex B. -- { dynObjData 3 } is deprecated. See Annex B. -- { dynObjData 4 } is deprecated. See Annex B. -- { dynObjData 5 } is deprecated. See Annex B. -- { dynObjData 6 } is deprecated. See Annex B. -- { dynObjData 7 } is deprecated. See Annex B. -- { dynObjData 8 } is deprecated. See Annex B. -- { dynObjData 9 } is deprecated. See Annex B. -- { dynObjData 10 } is deprecated. See Annex B. -- { dynObjData 11 } is deprecated. See Annex B. -- { dynObjData 12 } is deprecated. See Annex B. -- { dynObjData 13 } is deprecated. See Annex B. A.5.3. Dynamic Object Configuration dynObjConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF DynObjConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table consisting of an owner and status for each of the 13 dynamic object definitions." ::= { dynObjMgmt 3} dynObjConfigEntry OBJECT-TYPE SYNTAX DynObjConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table consisting of an owner and status for each of the 13 dynamic object definitions." INDEX {dynObjNumber} ::= {dynObjConfigTable 1} DynObjConfigEntry ::= SEQUENCE { dynObjConfigOwner OwnerString, dynObjConfigStatus ConfigEntryStatus} A.5.3.1. Dynamic Object Configuration Owner dynObjConfigOwner OBJECT-TYPE SYNTAX OwnerString ACCESS read-write STATUS mandatory DESCRIPTION "The entity that configured the associated dynamic object. This object may not be modified unless the associated dynObjConfigStatus object is equal to underCreation." DEFVAL {""} ::= {dynObjConfigEntry 1} A.5.3.2. Dynamic Object Configuration Status dynObjConfigStatus OBJECT-TYPE SYNTAX ConfigEntryStatus ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the state of the associated dynamic object. Depending on the validity checks that are performed on the dynamic object definition, a set request may or may not be honored. See Clause 5.2.4.1 for a complete description." ::= {dynObjConfigEntry 2} A.5.4. STMP Statistics stmpStatistics OBJECT IDENTIFIER ::= { stmp 1 } A.5.4.1. Number of Incoming STMP Packets stmp-inPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of Messages delivered to the STMP entity for processing." ::= { stmpStatistics 1 } A.5.4.2. Number of Outgoing STMP Packets stmp-outPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of STMP PDU's which were generated by the STMP protocol entity ." ::= { stmpStatistics 2 } A.5.4.3. Reserved -- node 3 is reserved for bad version in order to parallel SNMP, but it does not -- apply to STMP A.5.4.4. Reserved -- node 4 is reserved for bad community name in order to parallel SNMP, but it -- does not apply to STMP A.5.4.5. Reserved -- node 5 is reserved for bad community use in order to parallel SNMP, but it -- does not apply to STMP A.5.4.6. Number of Incoming STMP Packets with Parsing Errors stmp-inParseErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of OER errors encountered by the STMP protocol entity when decoding received STMP Messages." ::= { stmpStatistics 6 } A.5.4.7. Reserved -- node 7 is reserved for bad types in order to parallel SNMP, but it does not -- apply to STMP A.5.4.8. Number of Incoming STMP Packets indicating a Too Big Error stmp-inTooBigs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of STMP PDUs which were delivered to the STMP protocol entity with a Message Type of Error and Error Number of tooBig." ::= { stmpStatistics 8 } A.5.4.9. Number of Incoming STMP Packets indicating a No Such Name Error stmp-inNoSuchNames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of STMP PDUs which were delivered to the STMP protocol entity with a Message Type of Error and Error Number of noSuchName." ::= { stmpStatistics 9 } A.5.4.10. Number of Incoming STMP Packets indicating a Bad Value Error stmp-inBadValues OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of STMP PDUs which were delivered to the STMP protocol entity with a Message Type of Error and Error Number of badValue." ::= { stmpStatistics 10 } A.5.4.11. Number of Incoming STMP Packets indicating a Read-Only Error stmp-inReadOnlys OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of STMP PDUs which were delivered to the STMP protocol entity with a Message Type of Error and Error Number of readOnly." ::= { stmpStatistics 11 } A.5.4.12. Number of Incoming STMP Packets indicating a General Error stmp-inGenErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of STMP PDUs which were delivered to the STMP protocol entity with a Message Type of Error and Error Number of genError." ::= { stmpStatistics 12 } A.5.4.13. Reserved -- node 13 is reserved for total request vars in order to parallel SNMP, but it -- does not apply to STMP A.5.4.14. Reserved -- node 14 is reserved for total set vars in order to parallel SNMP, but it does -- not apply to STMP A.5.4.15. Number of Incoming STMP Get Requests stmp-inGetRequests OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of STMP Get-Request PDUs which have been accepted and processed by the STMP protocol entity." ::= { stmpStatistics 15 } A.5.4.16. Number of Incoming STMP Get Next Requests stmp-inGetNexts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of STMP Get-Next PDUs which have been accepted and processed by the STMP protocol entity." ::= { stmpStatistics 16 } A.5.4.17. Number of Incoming STMP Set Requests stmp-inSetRequests OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of STMP Set-Request PDUs which have been accepted and processed by the STMP protocol entity." ::= { stmpStatistics 17 } A.5.4.18. Number of Incoming STMP Get Responses stmp-inGetResponses OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of STMP Get-Response PDUs which have been accepted and processed by the STMP protocol entity." ::= { stmpStatistics 18 } A.5.4.19. Reserved -- node 19 is reserved for in trap responses in order to parallel SNMP, but it -- does not apply to STMP A.5.4.20. Number of Outgoing STMP Packets indicating a Too Big Error stmp-outTooBigs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of STMP PDUs which were generated by the STMP protocol entity with a Message Type of Error and Error Number of tooBig." ::= { stmpStatistics 20 } A.5.4.21. Number of Outgoing STMP Packets indicating a No Such Name Error stmp-outNoSuchNames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of STMP PDUs which were generated by the STMP protocol entity with a Message Type of Error and Error Number of noSuchname." ::= { stmpStatistics 21 } A.5.4.22. Number of Outgoing STMP Packets indicating a Bad Value Error stmp-outBadValues OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of STMP PDUs which were generated by the STMP protocol entity with a Message Type of Error and Error Number of badValue." ::= { stmpStatistics 22 } A.5.4.23. Number of Outgoing STMP Packets indicating a Read-Only Error stmp-outReadOnly OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of STMP PDUs which were generated by the STMP protocol entity with a Message Type of Error and Error Number of readOnly." ::= { stmpStatistics 23 } A.5.4.24. Number of Outgoing STMP Packets indicating a General Error stmp-outGenError OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of STMP PDUs which were generated by the STMP protocol entity with a Message Type of Error and Error Number of genErr." ::= { stmpStatistics 24 } A.5.4.25. Number of Outgoing STMP Get Requests stmp-outGetRequests OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of STMP PDU's with a Message Type of Get-Request, which have been generated by the STMP protocol entity." ::= { stmpStatistics 25 } A.5.4.26. Number of Outgoing STMP Get Next Requests stmp-outGetNexts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of STMP PDU's with a Message Type of Get-Next, which have been generated by the STMP protocol entity." ::= { stmpStatistics 26 } A.5.4.27. Number of Outgoing STMP Set Requests stmp-outSetRequests OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of STMP PDU's with a Message Type of Set-Request, which have been generated by the STMP protocol entity." ::= { stmpStatistics 27 } A.5.4.28. Number of Outgoing STMP Get Responses stmp-outGetResponses OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of STMP PDU's with a Message Type of Get-Response, which have been generated by the STMP protocol entity." ::= { stmpStatistics 28 } A.5.4.29. Reserved -- node 29 is reserved for in trap responses in order to parallel SNMP, but it -- does not apply to STMP A.5.4.30. Reserved -- node 30 is reserved for enable authentication traps to parallel SNMP, but it -- does not apply to STMP A.5.4.31. Number of Incoming STMP Set Request – No Replies stmp-inSetRequestsNoReply OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of STMP Set-Request No Reply PDUs which have been accepted and processed by the STMP protocol entity." ::= { stmpStatistics 31 } A.5.4.32. Number of Incoming STMP Set Responses stmp-inSetResponses OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of STMP Set-Response PDUs which have been accepted and processed by the STMP protocol entity." ::= { stmpStatistics 32 } A.5.4.33. Number of Incoming STMP Error Responses stmp-inErrorResponses OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of STMP Error-Response PDUs which have been accepted and processed by the STMP protocol entity." ::= { stmpStatistics 33 } A.5.4.34. Number of Outgoing STMP Set Request – No Replies stmp-outSetRequestsNoReply OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of STMP PDU's with a Message Type of Set-Request-No- Reply, which have been generated by the STMP protocol entity." ::= { stmpStatistics 34 } A.5.4.35. Number of Outgoing STMP Set Responses stmp-outSetResponses OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of STMP PDU's with a Message Type of Set-Response, which have been generated by the STMP protocol entity." ::= { stmpStatistics 35 } A.5.4.36. Number of Outgoing STMP Error Responses stmp-outErrorResponses OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of STMP PDU's with a Message Type of Error-Response, which have been generated by the STMP protocol entity." ::= { stmpStatistics 36 } A.5.5. STMP Configuration profilesSTMP OBJECT IDENTIFIER ::= { profiles 2 } -- This node is an identifier used to group all objects for support of -- configuration functions that are common to device types that support the STMP -- protocol. The objects under this node are placed under the -- Protocols\Profiles\STMP subtree within the NEMA node. A.5.5.1. Dynamic Object Persistence dynamicObjectPersistence OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The maximum power outage time in minutes that may occur before all STMP dynamic object definitions in a device shall be invalidated. If this object is set to zero then existing dynamic object definitions shall be invalidated on device power up. If this object is set to its maximum value (65535) the existing dynamic object definitions shall nominally persist for an infinite period (in practice this will be limited by the non-volatile memory capabilities of the device) This object shall not be invalidated due to power outages of any duration. A device that supports STMP dynamic objects shall support this object." DEFVAL {65535} ::= { profilesSTMP 1 } A.5.5.2. Dynamic Object Configuration ID dynamicObjectTable-ConfigID OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Specifies a relatively unique ID (e.g., this could be a counter, a check-sum, etc.) for the current values stored in the dynObjVariable and dynObjConfigOwner objects for all dynamic objects with a dynObjStatus of valid. This value shall be calculated on the change of any dynObjStatus to or from the valid state. This value reported by this object shall not change unless there has been a change in the data since the last request; however a genErr shall be returned if the unique ID value has not yet been updated. A management station will be able to detect any change in the configuration of dynamic objects by monitoring this value after it has established a baseline. " ::= { profilesSTMP 2 } A.6. Logical Names logicalNames OBJECT IDENTIFIER ::= { application 4 } -- This node is used to define objects to allow a mapping between logical device -- names and network addresses. A.6.1. Maximum Logical Name Translations logicalNameTranslationTable-maxEntries OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the maximum number of rows that may be implemented in the logical name translation table." ::= { logicalNames 1 } A.6.2. Logical Name Translation Table logicalNameTranslationTable OBJECT-TYPE SYNTAX SEQUENCE OF LogicalNameTranslationEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table defines the logical names of the other network entities with which the device may communicate and maps these names to the network addresses of those devices." ::= { logicalNames 2 } logicalNameTranslationEntry OBJECT-TYPE SYNTAX LogicalNameTranslationEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is one logical row of the logical name translation table." INDEX { logicalNameTranslation-index } ::= { logicalNameTranslationTable 1} LogicalNameTranslationEntry::=SEQUENCE { logicalNameTranslation-index INTEGER, logicalNameTranslation-logicalName OCTET STRING, logicalNameTranslation-networkAddress NetworkAddress, logicalNameTranslation-status RowStatusStatic } A.6.2.1. Index for the Logical Name Translation logicalNameTranslation-index OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the index into the logical name table." ::= { logicalNameTranslationEntry 1 } A.6.2.2. Logical Name for the Logical Name Translation logicalNameTranslation-logicalName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "This object defines the logical name of the network entity for which this row is defined." -- DEFVAL { internet '00000000'h } ::= { logicalNameTranslationEntry 2 } A.6.2.3. Network Address of the Logical Name Translation logicalNameTranslation-networkAddress OBJECT-TYPE SYNTAX NetworkAddress ACCESS read-write STATUS mandatory DESCRIPTION "This object defines the network address of the associated network entity for the given profile. If the transport profile is ‘internet,’ the network address is the IP address of the entity stored as an IpAddress. If the transport profile is ‘t2,’ there is no physical network address, but the entity is assigned a dummy IP address in order to abstract the mapping to the ipNetToMediaTable defined in MIB-II." DEFVAL { 0 } ::= { logicalNameTranslationEntry 3 } A.6.2.4. Logical Name Translation Status logicalNameTranslation-status OBJECT-TYPE SYNTAX RowStatusStatic ACCESS read-write STATUS mandatory DESCRIPTION "This object allows for the management of rows within the table." DEFVAL { invalid } ::= { logicalNameTranslationEntry 4 } A.7. Report Parameter Node globalReport OBJECT IDENTIFIER ::= { global 4 } -- This node is an identifier used to organize all objects for support of -- report functions that are common to most device types. -- NOTE—The event class table is presented first in order to ease the -- readability of the standard; however, the node numbers assigned to this -- table reflect the original node numbering used in the original 1996 -- specification in order to preserve backwards compatibility with existing -- systems. A.7.1. Maximum Event Classes Parameter maxEventClasses OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The object defines the number of rows in the eventClassTable that this device supports. This is a static table. EventClassTable.maxEventClasses:quantity Data Element EventClass" ::= { globalReport 5 } A.7.2. Event Class Table eventClassTable OBJECT-TYPE SYNTAX SEQUENCE OF EventClassEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table is used to configure event logging limits and log table maintenance. EventClassTable Entity Type static" ::= { globalReport 6 } eventClassEntry OBJECT-TYPE SYNTAX EventClassEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This defines a row in the Event Class Table EventClass Entity Type" INDEX { eventClassNumber } ::= { eventClassTable 1 } EventClassEntry ::= SEQUENCE { eventClassNumber INTEGER, eventClassLimit INTEGER, eventClassClearTime Counter, eventClassDescription OCTET STRING, eventClassNumRowsInLog INTEGER, eventClassNumEvents INTEGER } A.7.2.1. Event Class Number Parameter eventClassNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "This is a class value that is to be configured. EventClass.number:identifier Data Element" ::= { eventClassEntry 1 } A.7.2.2. Event Class Limit Parameter eventClassLimit OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the maximum number of events of the associated class to store in the log. Once the limit is reached, the oldest entry of the matching class will be overwritten by any new entry of the same class. If the value of this object is set to a number smaller than the current number of rows within this class in the eventLogTable, then the oldest entries shall be lost/deleted. The sum of all event class limits shall not exceed the maxEventLogSize object; if a SET operation to this object causes the sum of eventClassLimit objects to exceed maxEventLogSize, then the agent shall respond with a genErr. EventClass.eventLimit:quantity Data Element Event" ::= { eventClassEntry 2 } A.7.2.3. Event Class Clear Time Parameter eventClassClearTime OBJECT-TYPE SYNTAX Counter ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to clear multiple event log entries from the eventLogTable. All events of this class that have an eventLogTime equal to or less than this object shall be cleared from the eventLogTable. If this object has a value greater than the current value of globalTime, it shall prevent the logging of any events of this class. EventClass.clearTime:quantity Data Element second" DEFVAL {0} ::= { eventClassEntry 3 } A.7.2.4. Event Class Description Parameter eventClassDescription OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies a description of the class in ASCII characters. EventClass.description:text Data Element" ::= { eventClassEntry 4 } A.7.2.5. Event Class Number of Rows in Event Log Table Parameter eventClassNumRowsInLog OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "The number of rows for this class that currently exist in the eventLogTable. EventClass.currentEntries:quantity Data Element Event" ::= { eventClassEntry 5 } A.7.2.6. Class Event Log Counter Parameter eventClassNumEvents OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION " This object is a counter that gets incremented every time an event occurs for this class; it shall initialize to zero at power up. The value shall roll over each time it exceeds the maximum of 65535. EventClass.eventCounter:quantity Data Element Events" ::= { eventClassEntry 6 } A.7.3. Maximum Event Log Configurations Parameter maxEventLogConfigs OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The number of rows that exist in the static eventLogConfig table for this device. EventTypeTable.maxEventTypes:quantity Data Element EventType" ::= { globalReport 1} A.7.4. Event Log Configuration Table eventLogConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF EventLogConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing Event Log Configuration information. The number of rows in this table is equal to the maxEventLogConfigs object. This table defines the parameters that the device will monitor to create an event. EventTypeTable Entity Type static" ::= { globalReport 2 } eventLogConfigEntry OBJECT-TYPE SYNTAX EventLogConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This object defines an entry in the event log configuration table. EventType Entity Type" INDEX { eventConfigID } ::= { eventLogConfigTable 1 } EventLogConfigEntry ::= SEQUENCE { eventConfigID INTEGER, eventConfigClass INTEGER, eventConfigMode INTEGER, eventConfigCompareValue INTEGER, eventConfigCompareValue2 INTEGER, eventConfigCompareOID OBJECT IDENTIFIER, eventConfigLogOID OBJECT IDENTIFIER, eventConfigAction INTEGER, eventConfigStatus INTEGER } A.7.4.1. Event Log Configuration ID Parameter eventConfigID OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This object contains the row number which is used to identify the event associated with this row in the eventLogConfigTable. The number of event IDs shall not exceed the value indicated in the maxEventLogConfigs object. EventType.identifier:identifier Data Element" ::= { eventLogConfigEntry 1 } A.7.4.2. Event Log Configuration Class Parameter eventConfigClass OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "This object contains the class value to assign to the event associated with this row in the event configuration table. This value is used in the event log table to organize various events defined in this table into logical groupings. This value shall not exceed the maxEventClasses object value. NOTE2—The event cannot be logged if the EventClass has an eventClassLimit of zero (0), EventType.class:identifier Data Element " DEFVAL {1} ::= { eventLogConfigEntry 2 } A.7.4.3. Event Log Configuration Mode Parameter eventConfigMode OBJECT-TYPE SYNTAX INTEGER { other (1), onChange (2), greaterThanValue (3), smallerThanValue (4), hysteresisBound (5), periodic (6), andedWithValue (7) } ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the mode of operation for this event. The modes are defined as follows: Value Description other the event mode of operation is not described in this standard, refer to the device manual. onChange create a log entry when the object value referenced by eventConfigCompareOID changes. The values of eventConfigCompareValue and eventConfigCompareValue2 are ignored in this mode. greaterThanValue create a log entry when the object value referenced by eventConfigCompareOID becomes greater than the value of eventConfigCompareValue for the time (tenth seconds) defined by eventConfigCompareValue2 (zero means immediate logging). smallerThanValue create a log entry when the object value referenced by eventConfigCompareOID becomes less than the value of eventConfigCompareValue for the time (tenth seconds) defined by eventConfigCompareValue2 (zero means immediate logging). hysteresisBound create a log entry when the object value referenced by eventConfigCompareOID becomes less than or greater than the bound values. The lowerbound value is the lower value of eventConfigCompareValue and eventConfigCompareValue2; the upperbound value is the higher value of the two values. When the object value becomes greater than the upper bound value, subsequent logging of upperbound conditions shall not occur until the object value becomes less than the lower bound value. When the object value becomes less than the lower bound value, subsequent logging of lowerbound conditions shall not occur until the object value becomes greater than the upper bound value. periodic create a log entry every x seconds, where x is defined by the value stored in eventConfigCompareValue. The values stored in eventConfigCompareValue2 and eventConfigCompareOID are ignored in this mode. andedWithValue create a log entry when the object value referenced by eventConfigCompareOID ANDED with the value of eventConfigCompareValue is NOT equal to zero for the time (tenth seconds) defined by eventConfigCompareValue2 (zero means immediate logging). This allows monitoring of a specific bit; the condition becomes true anytime that any one of the selected bits become true. EventType.mode:code Data Element" DEFVAL {onChange} ::= { eventLogConfigEntry 3 } A.7.4.4. Event Log Configuration Compare Value Parameter eventConfigCompareValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This object contains the comparison value to use with eventConfigMode values (greaterThanValue, smallerThanValue, hysteresisBound ). No value within this object is necessary when the eventConfigMode-object has the value onChange (2). EventType.compareValue:number Data Element" DEFVAL {0} ::= { eventLogConfigEntry 4 } A.7.4.5. Event Log Configuration Compare Value 2 Parameter eventConfigCompareValue2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "If the eventConfigMode is set to hysteresisBound, this object specifies the second comparison value for the hysteresis. If the eventConfigMode is set to greaterThanValue, smallerThanValue, or andedWithValue, this object specifies the time (in tenth of seconds, +1 tenth / -0 tenths) for which the samples used for comparison must be true prior to the event condition becoming true. If the eventConfigMode is set to onChange or periodic, the value of this object shall be ignored. The amount of time the condition must be true is measured in tenths of a second. The accuracy of this timer is limited to +1 tenth of a second and –0 tenths of a second. If the event is true for at least the time shown in this parameter +1 tenth of a second, the condition shall trigger a log entry. It is recognized that some designs only sample the condition periodically, in which case the condition must be true for at least the time indicated by this object before the event becomes true and the event shall always become true if the condition is true for a duration equal to the value shown in this object plus 1 tenth of a second. EventType.compareValue2:number Data Element" DEFVAL {0} ::= { eventLogConfigEntry 5 } A.7.4.6. Event Log Configuration Compare Object Identifier Parameter eventConfigCompareOID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-write STATUS mandatory DESCRIPTION "This object contains the object identifier which references the value against which the comparison is made. If the eventConfigMode is set to periodic, the value of this object shall be ignored. If the eventConfigMode is set to greaterThanValue, smallerThanValue or hysteresisBound, this object must reference an object whose SYNTAX resolves to a ranged or unranged INTEGER. As with all other objects that are sub-ranged by a given implementation, an agent should return a badValue error if it receives a set command indicating an OID which is not supported by the implementation or which is not null. EventType.compareObject:identifier Data Element" DEFVAL {null} ::= { eventLogConfigEntry 6 } A.7.4.7. Event Log Configuration Log Object Identifier Parameter eventConfigLogOID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-write STATUS mandatory DESCRIPTION "This object contains the object identifier which indicates what value to log when a condition or event occurs (e.g., log the phase display when the watchdog alarm status changes). As with all other objects that are sub-ranged by a given implementation, an agent should return a badValue error if it receives a set command indicating a value which is not supported by the implementation. The valid value range of this object shall not include any values, other than null, that do not correspond to objects that may exist within the agent, although it may be further restricted. The valid value range of this object shall not include objects under the following nodes: • Security - { nema transportation devices global security } • CHAP - { nema transportation protocols layers chap } EventType.logObject:identifier Data Element" DEFVAL {null} ::= { eventLogConfigEntry 7 } A.7.4.8. Event Log Configuration Action Parameter eventConfigAction OBJECT-TYPE SYNTAX INTEGER { other (1), disabled (2), log (3) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object indicates what action shall take place when this event occurs. disabled - no entry will be recorded due to this event. log - an entry will be recorded in the event log table when this event occurs. EventType.action:code Data Element" DEFVAL {disabled} ::= { eventLogConfigEntry 8 } A.7.4.9. Event Log Configuration Status Parameter eventConfigStatus OBJECT-TYPE SYNTAX INTEGER { other (1), disabled (2), log (3), error (4) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object indicates the current status of the configured event. Upon setting any object in this row of the eventLogConfigTable, the agent will determine if the setting is valid and will set this object to one of the following states: other indicates that the action is successfully set to a mode other than that defined in this standard disabled indicates that the action is set to disabled log indicates that the action is successfully set to the log state after passing consistency checks. error indicates that the requested action could not be implemented due to a consistency check EventType.status:code Data Element" ::= { eventLogConfigEntry 9 } A.7.5. Maximum Event Log Size Parameter maxEventLogSize OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The maximum, fixed number of rows that can be utilized within the eventLogTable. EventTable.maxEventLogSize:quantity Data Element Event" ::= { globalReport 3} A.7.6. Event Log Table eventLogTable OBJECT-TYPE SYNTAX SEQUENCE OF EventLogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing Event History data collected. A request for an object from a row that has not been instantiated or has been cleared shall return a noSuchName error. EventTable Entity Type dynamic status" ::= { globalReport 4 } eventLogEntry OBJECT-TYPE SYNTAX EventLogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This object defines an entry in the event log table Event Entity Type" INDEX { eventLogClass, eventLogNumber } ::= { eventLogTable 1 } EventLogEntry ::= SEQUENCE { eventLogClass INTEGER, eventLogNumber INTEGER, eventLogID INTEGER, eventLogTime Counter, eventLogValue Opaque } A.7.6.1. Event Log Class Parameter eventLogClass OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "This object contains the class of the associated event as defined in the eventLogConfig Table. ClassLog.class:identifier Data Element" ::= { eventLogEntry 1 } A.7.6.2. Event Log Number Parameter eventLogNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "The event number within this class for this event. Event numbers shall be assigned starting at 1 and shall increase to the value specified by the associated eventClassLimit for the class associated with the rows. Events shall maintain a chronological ordering in the table with the oldest event of a class occupying the row with eventNumber = 1, and subsequent events filling subsequent rows. This ordering shall be maintained for those rows still remaining when events are cleared. Event.number:identifier Data Element" ::= { eventLogEntry 2 } A.7.6.3. Event Log ID Parameter eventLogID OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This object contains the event configuration ID (from the eventLogConfigTable) that caused this table entry. It indicates the row in the eventLogConfig table responsible for this event entry. Event.type:identifier Data Element" ::= { eventLogEntry 3 } A.7.6.4. Event Log Time Parameter eventLogTime OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The time that the event was detected. If the device supports the globalTime object, the value shall reflect the value of globalTime when the event occurred, otherwise this shall be the time in seconds since the device powered up. The event shall be detected and timestamped within one second from the event becoming true. The event shall be logged in the table within five seconds of the event being detected. These timing resolutions may be modified by a device profile. Event.logTime:quantity Data Element second" ::= { eventLogEntry 4 } A.7.6.5. Event Log Value Parameter eventLogValue OBJECT-TYPE SYNTAX Opaque ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is set to the BER encoding of the value referenced by the eventConfigLogOID of the associated eventLogID when the event was logged. Its length is variable. The value shall not contain any padding characters either before or after the values. NOTE—Opaque objects are doubly wrapped. For SNMP operations, which use BER, this would be {type, length, {type, length, value}}. For example, a zero-length octet string, would be encoded in BER as 0x44 02 04 00. For STMP or SFMP operations, which use OER, this would be { length, {type, length, value}}. For example, the same example would be encoded in OER as 0x02 04 00. Event.logValue:frame Data Element" ::= { eventLogEntry 5 } A.7.7. Total Event Log Counter Parameter numEvents OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION " This object is a counter that gets incremented every time an event occurs and shall initialize to zero at power up. The value shall roll over each time it exceeds the maximum of 65535. EventTable.numEvents:quantity Data Element Events" ::= { globalReport 7 } A.8. Security Objects security OBJECT IDENTIFIER ::= {global 5} -- This node is an identifier used to group all objects related to the -- assignment of community names and the access rights they provide. -- These objects were previously defined in NTCIP 1201, but were moved -- here as they relate to the protocols more than the end application. A.8.1. Community Name Administrator Parameter communityNameAdmin OBJECT-TYPE SYNTAX OCTET STRING (SIZE(8..16)) ACCESS read-write STATUS mandatory DESCRIPTION "This object is the community name that must be used to specifically gain access to information under the security node. A message with this value in the community name field of an SNMP message has user read-write access to the security node objects and all other objects implemented in the device. The syntax is defined as an OCTET STRING and therefore any character can have a value of 0..255." DEFVAL { "administrator" } ::= { security 1 } A.8.2. Maximum Community Names Parameter communityNamesMax OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the maximum number of rows that are implemented in the community name table." ::= { security 2 } A.8.3. Community Names Table communityNameTable OBJECT-TYPE SYNTAX SEQUENCE OF CommunityNameTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table defines the community names that can appear in the community name field of the SNMP message and access privileges associated with that community name." ::= { security 3 } communityNameTableEntry OBJECT-TYPE SYNTAX CommunityNameTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is the row index of information in the community name table." INDEX { communityNameIndex } ::= { communityNameTable 1} CommunityNameTableEntry::=SEQUENCE { communityNameIndex INTEGER, communityNameUser OCTET STRING, communityNameAccessMask Gauge } A.8.3.1. Community Name Index Parameter communityNameIndex OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "This object defines the row index into the communityNameTable. This value shall not exceed the communityNamesMax object value." ::= { communityNameTableEntry 1 } A.8.3.2. User Community Name Parameter communityNameUser OBJECT-TYPE SYNTAX OCTET STRING (SIZE(6..16)) ACCESS read-write STATUS mandatory DESCRIPTION "This object defines a community name value that a security administrator can assign user read-write access to information (other than security) in a device. A message with this value in the community name field of an SNMP/SFMP message has user access rights as defined in the communityNameAccessMask. The syntax is defined as an OCTET STRING and therefore any character can have a value of 0..255." DEFVAL { "public" } ::= { communityNameTableEntry 2 } A.8.3.3. User Community Name Mask Parameter communityNameAccessMask OBJECT-TYPE SYNTAX Gauge ACCESS read-write STATUS mandatory DESCRIPTION "This object defines a 32 bit mask that can be used to associate 'write access' with a community name. A value of 0x00 00 00 00 grants the community name user read-only access and overrides any individual object's read-write access clause. A value of 0xFF FF FF FF grants the community name user read-write access and an individual object's read- write access clause applies. Values other than 0x00 00 00 00 and 0xFF FF FF FF are implementation specific and may limit viewing and/or accessing the information in a device." DEFVAL { 4294967295 } ::= { communityNameTableEntry 3 } END