-- OIDref derived MIB transcription. Original PDF: https://www.ntcip.org/file/2018/11/NTCIP1103v0352b.pdf -- Publisher front matter and notices follow as comments. -- A Joint Standard of AASHTO, ITE, and NEMA -- -- -- -- NTCIP 1103 version v03 -- -- National Transportation -- Communications for ITS Protocol -- -- Transportation Management Protocols -- (TMP) -- -- Published in December 2016 -- -- -- -- -- Published by -- -- American Association of State Highway and Transportation Officials (AASHTO) -- 444 North Capitol Street, NW, Suite 249 -- Washington, DC 20001 -- -- Institute of Transportation Engineers (ITE) -- 1627 I (“Eye”) Street, NW, Suite 600 -- Washington, DC 20006 -- -- National Electrical Manufacturers Association (NEMA) -- 1300 North 17th Street, Suite 900 -- Rosslyn, VA 22209-3801 version 1103 v0352jpo -- -- -- -- -- 2016 AASHTO / ITE / NEMA. All rights reserved.All rights reserved. -- -- -- NOTICES -- -- Copyright Notice -- --  2016 by the American Association of State Highway and Transportation Officials (AASHTO), the -- Institute of Transportation Engineers (ITE), and the National Electrical Manufacturers Association -- (NEMA). All intellectual property rights, including, but not limited to, the rights of reproduction, translation, -- and display are reserved under the laws of the United States of America, the Universal Copyright -- Convention, the Berne Convention, and the International and Pan American Copyright Conventions. -- Except as licensed or permitted, you may not copy these materials without prior written permission from -- AASHTO, ITE, or NEMA. Use of these materials does not give you any rights of ownership or claim of -- copyright in or to these materials. -- -- Visit www.ntcip.org for other copyright information, for instructions to request reprints of excerpts, and to -- request reproduction that is not granted below. -- -- -- PDF File License Agreement -- -- To the extent that these materials are distributed by AASHTO/ITE/NEMA in the form of an Adobe® -- Portable Document Format (PDF) electronic data file (the “PDF File”), AASHTO/ITE/NEMA authorizes -- each registered PDF file user to view, download, copy, or print the PDF file available from the authorized -- website, subject to the terms and conditions of this license agreement: -- -- a) you may download one copy of each PDF file for personal, noncommercial, and intra-organizational -- use only; -- b) ownership of the PDF file is not transferred to you; you are licensed to use the PDF file; -- c) you may make one more electronic copy of the PDF file, such as to a second hard drive or burn to a -- CD; -- d) you agree not to copy, distribute, or transfer the PDF file from that media to any other electronic -- media or device; -- e) you may print one paper copy of the PDF file; -- f) you may make one paper reproduction of the printed copy; -- g) any permitted copies of the PDF file must retain the copyright notice, and any other proprietary -- notices contained in the file; -- h) the PDF file license does not include (1) resale of the PDF file or copies, (2) republishing the content -- in compendiums or anthologies, (3) publishing excerpts in commercial publications or works for hire, -- (4) editing or modification of the PDF file except those portions as permitted, (5) posting on network -- servers or distribution by electronic mail or from electronic storage devices, and (6) translation to -- other languages or conversion to other electronic formats; -- i) other use of the PDF file and printed copy requires express, prior written consent. -- -- -- Data Dictionary and MIB Distribution Permission -- -- To the extent that these materials are distributed by AASHTO/ITE/NEMA in the form of a data dictionary -- (“DD”) or management information base (“MIB”), AASHTO/ITE/NEMA extend the following permission: -- -- You may make and/or distribute unlimited copies, including derivative works, of the DD or MIB, including -- copies for commercial distribution, provided that: -- -- a) each copy you make and/or distribute contains the citation “Derived from NTCIP 0000 [insert the -- document number]. Used by permission of AASHTO/ITE/NEMA.”; -- -- Draft NTCIP 1103 v03.39 -- Page iii -- -- b) the copies or derivative works are not made part of the standards publications or works offered by -- other standards developing organizations or publishers or as works-for-hire not associated with -- commercial hardware or software products intended for field implementation; -- c) use of the DD or MIB is restricted in that the syntax fields may be modified only to reflect a more -- restrictive subrange or enumerated values; -- d) the description field may be modified but only to the extent that: (a) only those bit values or -- enumerated values that are supported are listed; and (b) the more restrictive subrange is expressed. -- -- These materials are delivered “AS IS” without any warranties as to their use or performance. -- -- AASHTO/ITE/NEMA and their suppliers do not warrant the performance or results you may obtain -- by using these materials. AASHTO/ITE/NEMA and their suppliers make no warranties, express or -- implied, as to noninfringement of third party rights, merchantability, or fitness for any particular -- purpose. In no event will AASHTO/ITE/NEMA or their suppliers be liable to you or any third party -- for any claim or for any consequential, incidental or special damages, including any lost profits or -- lost savings, arising from your reproduction or use of these materials, even if an -- AASHTO/ITE/NEMA representative has been advised of the possibility of such damages. -- -- Some states or jurisdictions do not allow the exclusion or limitation of incidental, consequential, or special -- damages, or the exclusion of implied warranties, so the above limitations may not apply to a given user. -- -- Use of these materials does not constitute an endorsement or affiliation by or between AASHTO, ITE, or -- NEMA and the user, the user’s company, or the products and services of the user’s company. -- -- If the user is unwilling to accept the foregoing restrictions, he or she should immediately return these -- materials. -- -- -- Content and Liability Disclaimer -- -- The information in this publication was considered technically sound by the consensus of persons -- engaged in the development and approval of the document at the time it was developed. Consensus -- does not necessarily mean that there is unanimous agreement among every person participating in the -- development of this document. -- -- AASHTO, ITE, and NEMA standards and guideline publications, of which the document contained herein -- is one, are developed through a voluntary consensus standards development process. This process -- brings together volunteers and/or seeks out the views of persons who have an interest in the topic -- covered by this publication. While AASHTO, ITE, and NEMA administer the process and establish rules to -- promote fairness in the development of consensus, they do not write the document and they do not -- independently test, evaluate, or verify the accuracy or completeness of any information or the soundness -- of any judgments contained in their standards and guideline publications. -- -- AASHTO, ITE, and NEMA disclaim liability for any personal injury, property, or other damages of any -- nature whatsoever, whether special, indirect, consequential, or compensatory, directly or indirectly -- resulting from the publication, use of, application, or reliance on this document. AASHTO, ITE, and NEMA -- disclaim and make no guaranty or warranty, express or implied, as to the accuracy or completeness of -- any information published herein, and disclaims and makes no warranty that the information in this -- document will fulfill any of your particular purposes or needs. AASHTO, ITE, and NEMA do not undertake -- to guarantee the performance of any individual manufacturer or seller’s products or services by virtue of -- this standard or guide. -- -- In publishing and making this document available, AASHTO, ITE, and NEMA are not undertaking to -- render professional or other services for or on behalf of any person or entity, nor are AASHTO, ITE, and -- NEMA undertaking to perform any duty owed by any person or entity to someone else. Anyone using this -- -- document should rely on his or her own independent judgment or, as appropriate, seek the advice of a -- competent professional in determining the exercise of reasonable care in any given circumstances. -- Information and other standards on the topic covered by this publication may be available from other -- sources, which the user may wish to consult for additional views or information not covered by this -- publication. -- -- AASHTO, ITE, and NEMA have no power, nor do they undertake to police or enforce compliance with the -- contents of this document. AASHTO, ITE, and NEMA do not certify, test, or inspect products, designs, or -- installations for safety or health purposes. Any certification or other statement of compliance with any -- health or safety-related information in this document shall not be attributable to AASHTO, ITE, or NEMA -- and is solely the responsibility of the certifier or maker of the statement. -- -- -- Trademark Notice -- -- NTCIP is a trademark of AASHTO/ITE/NEMA. All other marks mentioned in this standard are the -- trademarks of their respective owners. -- -- NTCIP 1103 v03.52 -- Page i -- -- -- ACKNOWLEDGEMENTS -- -- -- NTCIP 1103 v03 was prepared by the NTCIP Base Standards and Profiles 2 Working Group (BSP2 WG), -- which is a subdivision of the Joint Committee on the NTCIP. The Joint Committee on the NTCIP is -- organized under a Memorandum of Understanding among the American Association of State Highway -- and Transportation Officials (AASHTO), the Institute of Transportation Engineers (ITE), and the National -- Electrical Manufacturers Association (NEMA). The Joint Committee on the NTCIP consists of six -- representatives from each of the standards organizations, and provides guidance for NTCIP -- development. -- -- At the time that NTCIP 1103 v03 was prepared, the following individuals were voting members of the -- NTCIP BSP2 WG: -- -- • Doug Crawford (Chair) • Alexis Mousadi -- • Ralph Boaz • Bryan Mulligan -- • Robert Lopes • Peter Ragsdale -- • Greg Mizell • Robert Rausch -- -- Other individuals providing input to NTCIP 1103 v03 include: -- -- • Blake Christie • Justin Anderson -- -- The following individuals were observing members of NTCIP BSP2 WG: -- -- • Russ Brookshire • Amit Misra -- • James Daley • Joerg Rosenbohm -- • Larry Head • Mark Simpson -- • Manny Insignares • Douglas Tarico -- • Patrick Klos • Andrew Valdez -- • Joseph Knapka • Kenneth Vaughn -- • Stephane Lapierre -- -- In addition to the many volunteer efforts, recognition is also given to those organizations that supported -- the efforts of BSP2 WG by providing comments and funding, including: -- -- • U.S. Department of Transportation ITS Joint • Parsons -- Program Office • Peek Traffic Corporation -- • AECom Corp. • Peter Ragsdale -- • Applied Information, Inc. • Pillar Consulting -- • Citizant • Siemens Industry, Inc. -- • Consensus Systems Technologies • Southwest Research Institute -- • Econolite Control Products, Inc. • The University of Arizona -- • Florida DOT—Tampa Bay District 7 • TransCore ITS Inc. -- • Intelight Inc. • Trevilon Corp. -- • Kapsch • Ver-Mac Inc. -- • Klos Technologies, Inc. • WSDOT, SC REGION -- • McCain Inc. -- -- -- -- -- © 2016 AASHTO / ITE / NEMA Do Not Copy Without Written Permission -- -- NTCIP 1103 v03.52 -- Page ii -- -- -- FOREWORD -- -- -- NTCIP 1103 v03 defines a composite application layer protocol for the management of transportation -- equipment. The composite protocol consists of three component protocols: the Internet-standard Simple -- Network Management Protocol (SNMP), the Simple Fixed Message Protocol (SFMP), and the Simple -- Transportation Management Protocol (STMP). The protocols are concerned with the procedures for -- exchanging information as well as the format in which the information is exchanged, and each of the three -- protocols provide the same base services, but are designed with different needs in mind. NTCIP 1103 -- v03 also defines a limited number of data elements necessary to manage these protocols. The data -- elements are defined according to the rules of NTCIP 8004 v02. Data elements in NTCIP 1103 v03 have -- been updated in accordance with and to reflect changes introducted in NTCIP 8004 v02. When related to -- the ISO OSI Reference model, these protocols are concerned with the upper three layers (application, -- session, and presentation layer). NTCIP 1103 v03 contains two normative and two informative annexes. -- NTCIP 1103 v03 uses only metric units. -- -- NTCIP 1103 v03 is also an NTCIP Base Standard. NTCIP Base Standards provide definitions of the -- procedures and data formats for use within NTCIP systems. For more information about NTCIP -- standards, visit the NTCIP Web Site at www.ntcip.org. NTCIP 1103 v03 defines requirements that are -- applicable to all NTCIP environments and also contains optional and conditional sections that are -- applicable to specific environments for which they are intended. -- -- The following keywords apply to NTCIP 1103 v03: AASHTO, ITE, NEMA, NTCIP, protocol, message, -- transportation, simple, TMP, SNMP, SFMP, STMP, trap, traps. -- -- User Comment Instructions -- -- The term “User Comment” includes any type of written inquiry, comment, question, or proposed revision, -- from an individual person or organization, about any part of this standards publication’s content. A -- “Request for Interpretation” of this standards publication is also classified as a User Comment. User -- Comments are solicited at any time. In preparation of this NTCIP standards publication, input of users -- and other interested parties was sought and evaluated. -- -- All User Comments are referred to the committee responsible for developing and/or maintaining this -- standards publication. The committee chairperson, or their designee, may contact the submitter for -- clarification of the User Comment. When the committee chairperson or designee reports the committee’s -- consensus opinion related to the User Comment, with that opinion forwarded to the submitter. The -- committee chairperson may report that action on the User Comment may be deferred to a future -- committee meeting and/or a future revision of the standards publication. Previous User Comments and -- their disposition may be available for reference and information at www.ntcip.org. -- -- A User Comment should be submitted to this address: -- -- NTCIP Coordinator -- National Electrical Manufacturers Association -- 1300 North 17th Street, Suite 900 -- Rosslyn, Virginia 22209-3801 -- e-mail: ntcip@nema.org -- -- A User Comment should be submitted in the following form: -- -- Standards Publication number and version: -- Page: -- Section, Paragraph, or Clause: -- Comment: -- -- -- Do Not Copy Without Written Permission © 2016 AASHTO / ITE / NEMA -- -- NTCIP 1103 v03.52 -- Page iii -- -- Editorial or Substantive?: -- Suggested Alternative Language: -- -- Please include your name, organization, and address in your correspondence. -- -- Approvals -- -- NTCIP 1103 v03 was separately balloted and approved by AASHTO, ITE, and NEMA after -- recommendation by the Joint Committee on the NTCIP. Each organization has approved this standard as -- the following standard type, as of the date: -- -- AASHTO—Standard Specification; September 2016 -- ITE—Software Standard; [month, year] -- NEMA—Standard; August 2016 -- -- History -- -- In 1992, the NEMA 3TS Transportation Management Systems and Associated Control Devices Section -- began the effort to develop the NTCIP. The Transportation Section’s purpose was to respond to user -- needs to include standardized systems communication in the NEMA TS 2 standard, Traffic Controller -- Assemblies. Under the guidance of the Federal Highway Administration’s NTCIP Steering Group, the -- NEMA effort was expanded to include the development of communications standards for all -- transportation field devices that could be used in an Intelligent Transportation Systems (ITS) network. -- -- In September 1996, an agreement was reached among AASHTO, ITE, and NEMA to jointly develop, -- approve, and maintain NTCIP standards. In late 1998, the Base Standards and Protocols Working Group -- was tasked with the effort to develop and maintain base standards for the NTCIP. In late 2003, the Joint -- Committee on the NTCIP merged the Base Standards and Protocols Working Group with the Profiles -- Working Group and the new group was designated the Base Standards, Protocols, and Profiles Working -- Group. The first meeting of the merged working group was held in January 2004. -- -- From 1996 to 2004, parts of NTCIP 1103 v02, including the definition of STMP, were defined in NTCIP -- 1101:1996 / NEMA TS 3.2. However, to provide a more organized and modular set of standards, NTCIP -- 1101:1996 was separated into three distinct standards: NTCIP 1103 v02, which includes the definition of -- STMP; NTCIP 1102:2004, which defines the Octet Encoding Rules (OER); and NTCIP 8004 v02, which -- defines the Structure and Management of Transportation Information (SMI). These three standards -- completely replace NTCIP 1101:1996 / NEMA TS 3.2. -- -- NTCIP 1103 v01.27, January 2009—In October 2004, v01.25 was Accepted as a Recommended -- Standard by the Joint Committee on the NTCIP. In June 2005, pre-ballot comments on -- community name were addressed and v01.26 was sent for SDO balloting. In November 2005, -- NTCIP 1103 v01 was Jointly Approved. In December 2008, NTCIP 1103 v01.27 was edited and -- published. -- -- NTCIP 1103 v02.10, May 2006—Developed and incorporated the NTCIP Trap mechanism and -- proposed as version 02 User Comment Draft. December 2006—Standards Bulletin B0117 sent -- v02.10b for review. -- -- In December 2007, the NTCIP Joint Committee agreed to remove the trap mechanism from -- NTCIP 1103 v02, and to increment to a proposed new major version NTCIP 1103 v03 to define -- traps. January 2008—Addressed user comments in v02.14. -- -- NTCIP 1103 v02.17, July 2010—In January 2008, the NTCIP 1103 v02.14 was revised as a -- proposed Recommended Standard, which in February 2008 was accepted by the NTCIP Joint -- Committee as a Recommended Standard. From 2008 to April 2009, NTCIP 1103 v02.16 was -- -- -- -- -- © 2016 AASHTO / ITE / NEMA Do Not Copy Without Written Permission NTCIP1103v0352-RechMech DEFINITIONS ::= BEGIN IMPORTS Counter, Opaque, NetworkAddress, null FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 Application, OerString FROM NTCIP8004-2008; -- EXPORTS EVERYTHING recMech OBJECT IDENTIFIER ::= { application 9 } -- 1.3.6.1.4.1.1206.4.1.1.7.9 -- This node is an identifier used to organize all objects for -- support of recording mechanism functions that are found in devices. -- NOTE—The recording mechanism class table is presented first to ease -- the readability of the standard. maxRecClasses OBJECT-TYPE SYNTAX INTEGER (1..254) ACCESS read-only STATUS mandatory DESCRIPTION " The object defines the number of rows in the recClassTable that this device supports. This is a static table. RecClass 1.3.6.1.4.1.1206.4.1.1.7.9.1 " ::= { recMech 1 } recClassTable OBJECT-TYPE SYNTAX SEQUENCE OF RecClassEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table is used to configure recording mechanism limits and recording table maintenance. static 1.3.6.1.4.1.1206.4.1.1.7.9.2 " ::= { recMech 2 } recClassEntry OBJECT-TYPE SYNTAX RecClassEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This object defines a row in the Recording Mechanism Class Table 1.3.6.1.4.1.1206.4.1.1.7.9.2.1 " INDEX { recClassNumber } ::= { recClassTable 1 } RecClassEntry ::= SEQUENCE { recClassNumber INTEGER, recClassLimit INTEGER, recClassClearTime Counter, recClassDescription OCTET STRING, recClassNumRecordings INTEGER, recClassRecordingCounter INTEGER } recClassNumber OBJECT-TYPE SYNTAX INTEGER (1..254) ACCESS read-only STATUS mandatory DESCRIPTION "This is a class value that is to be configured. 1.3.6.1.4.1.1206.4.1.1.7.9.2.1.1 " ::= { recClassEntry 1 } recClassLimit OBJECT-TYPE SYNTAX INTEGER (0..254) ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the maximum number of recordings of the associated class to store in the device. Once the limit is reached, the oldest recording of the matching class (based on recordingTriggerTime) is overwritten by any new recording of the same class. If the value of this object is set to a number smaller than the current number of rows within this class in the recRecordingTable, then the oldest entries shall be lost/deleted. The sum of all recording mechanism class limits shall not exceed the maxRecRecordings object; if a SET operation to this object causes the sum of recClassLimit objects to exceed maxRecRecordings, then the agent shall respond with a genErr. The recording cannot be logged if the recClass has an recClassLimit of zero (0). Recording 1.3.6.1.4.1.1206.4.1.1.7.9.2.1.2 " ::= { recClassEntry 2 } recClassClearTime OBJECT-TYPE SYNTAX Counter ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to clear multiple recordings from the recRecordingTable. All completed recordings of this class that have a recRecordingTriggerTime equal to or less than this object shall be cleared from the recRecordingTable. If this object has a value greater than the current value of globalTime, it shall prevent the triggering of any recordings of this class. second 1.3.6.1.4.1.1206.4.1.1.7.9.2.1.3 " DEFVAL {0} ::= { recClassEntry 3 } recClassDescription OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies a description of the class in ASCII characters. 1.3.6.1.4.1.1206.4.1.1.7.9.2.1.4 " ::= { recClassEntry 4 } recClassNumRecordings OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "The number of recordings for this class that currently exist in the recRecordingTable. Recording 1.3.6.1.4.1.1206.4.1.1.7.9.2.1.5 " ::= { recClassEntry 5 } recClassRecordingCounter OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION " This object is a counter that gets incremented every time a recording occurs for this class; it shall initialize to zero at power up. The value shall roll over each time it exceeds the maximum of 65535. Recording 1.3.6.1.4.1.1206.4.1.1.7.9.2.1.6 " ::= { recClassEntry 6 } maxRecConfigs OBJECT-TYPE SYNTAX INTEGER (1..65534) ACCESS read-only STATUS mandatory DESCRIPTION "The number of rows that exist in the static recMechRecordingConfig table for this device. RecordType 1.3.6.1.4.1.1206.4.1.1.7.9.3 " ::= { recMech 3} recMinSamplePeriod OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The minimum sample period for recordings supported by the device in units of 0.1 milliseconds. Time 1.3.6.1.4.1.1206.4.1.1.7.9.4 " ::= { recMech 4} recMaxSamplePeriod OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The maximum sample period for recordings supported by the device in units of 0.1 milliseconds. Time 1.3.6.1.4.1.1206.4.1.1.7.9.5 " ::= { recMech 5} recSamplePeriodResolution OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The sample period resolution for recordings supported by the device in units of 0.1 milliseconds. Allowable sample periods are restricted to (recMinSamplePeriod + recSamplePeriodResolution * n) where n is integer, 0 <= n, and n <= (recMaxSamplePeriod-recMinSamplePeriod)/recSamplePeriodResolution Time 1.3.6.1.4.1.1206.4.1.1.7.9.6 " ::= { recMech 6} recConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF RecConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing Recording Mechanism Configuration information. The number of rows in this table is equal to the maxRecConfigs object. This table defines the parameters that the device monitors to create a recording. static 1.3.6.1.4.1.1206.4.1.1.7.9.7 " ::= { recMech 7 } recConfigEntry OBJECT-TYPE SYNTAX RecConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This object defines an entry in the recording configuration table. 1.3.6.1.4.1.1206.4.1.1.7.9.7.1 " INDEX { recConfigID } ::= { recConfigTable 1 } RecConfigEntry ::= SEQUENCE { recConfigID INTEGER, recConfigClass INTEGER, recConfigMode INTEGER, recConfigCompareValue INTEGER, recConfigCompareValue2 INTEGER, recConfigCompareOID OBJECT IDENTIFIER, recConfigRecordOID OBJECT IDENTIFIER, recConfigTriggerPoint INTEGER, recConfigSamplePeriod INTEGER, recConfigSampleOID OBJECT IDENTIFIER, recConfigNumEntries INTEGER, recConfigAction INTEGER, recConfigStatus INTEGER } recConfigID OBJECT-TYPE SYNTAX INTEGER (1..65534) ACCESS read-only STATUS mandatory DESCRIPTION "This object contains the row number which is used to identify the recording associated with this row in the recConfigTable. The number of recording configuration IDs shall not exceed the value indicated in the maxRecConfigs object. 1.3.6.1.4.1.1206.4.1.1.7.9.7.1.1 " ::= { recConfigEntry 1 } recConfigClass OBJECT-TYPE SYNTAX INTEGER (1..254) ACCESS read-write STATUS mandatory DESCRIPTION "This object contains the class value to assign to the recording associated with this row in the recording configuration table. This value is used in the recording table to organize various recordings defined in this table into logical groupings. This value shall not exceed the maxRecClasses object value. NOTE—A recording cannot be recorded if the RecClass has an recClassLimit of zero (0). 1.3.6.1.4.1.1206.4.1.1.7.9.7.1.2 " DEFVAL {1} ::= { recConfigEntry 2 } recConfigMode OBJECT-TYPE SYNTAX INTEGER { other (1), onChange (2), greaterThanValue (3), smallerThanValue (4), hysteresisBound (5), periodic (6), andedWithValue (7) } ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the mode of operation for this recording. The modes are defined as follows: Value Description other the recording mode of operation is not described in this standard, refer to the device manual. onChange trigger a recording when the object value referenced by recConfigCompareOID changes. The values of recConfigCompareValue and recConfigCompareValue2 are ignored in this mode. greaterThanValue trigger a recording when the object value referenced by recConfigCompareOID becomes greater than the value of recConfigCompareValue for the time (tenth seconds) defined by recConfigCompareValue2 (zero means immediate logging). smallerThanValue trigger a recording when the object value referenced by recConfigCompareOID becomes less than the value of recConfigCompareValue for the time (tenth seconds) defined by recConfigCompareValue2 (zero means immediate logging). hysteresisBound trigger a recording when the object value referenced by recConfigCompareOID becomes less than or greater than the bound values. The lowerbound value is the lower value of recConfigCompareValue and recConfigCompareValue2; the upperbound value is the higher value of the two values. When the object value becomes greater than the upper bound value, subsequent triggering of upperbound conditions shall not occur until the object value becomes less than the lower bound value. When the object value becomes less than the lower bound value, subsequent triggering of lowerbound conditions shall not occur until the object value becomes greater than the upper bound value. periodic trigger a recording every x seconds, where x is defined by the value stored in recConfigCompareValue. The values stored in recConfigCompareValue2 and recConfigCompareOID are ignored in this mode. andedWithValue trigger a recording when the object value referenced by recConfigCompareOID ANDED with the value of recConfigCompareValue is NOT equal to zero for the time (tenth seconds) defined by recConfigCompareValue2 (zero means immediate logging). This allows monitoring of a specific bit; the condition becomes true anytime that any one of the selected bits become true. 1.3.6.1.4.1.1206.4.1.1.7.97.1.3 " DEFVAL {onChange} ::= { recConfigEntry 3 } recConfigCompareValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This object contains the comparison value to use with recConfigMode values (greaterThanValue, smallerThanValue, hysteresisBound ). No value within this object is necessary when the recConfigMode-object has the value onChange (2). 1.3.6.1.4.1.1206.4.1.1.7.97.1.4 " DEFVAL {0} ::= { recConfigEntry 4 } recConfigCompareValue2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "If the recConfigMode is set to hysteresisBound, this object specifies the second comparison value for the hysteresis. If the recConfigMode is set to greaterThanValue, smallerThanValue, or andedWithValue, this object specifies the time (in tenth of seconds, +1 tenth / -0 tenths) for which the samples used for comparison are true prior to the triggering condition becoming true. If the recConfigMode is set to onChange or periodic, the value of this object shall be ignored. The amount of time the condition istrue is measured in tenths of a second. The accuracy of this timer is limited to +1 tenth of a second and –0 tenths of a second. If the trigger is true for at least the time shown in this parameter +1 tenth of a second, the condition shall trigger a recording. It is recognized that some designs only sample the condition periodically, in which case the condition is deemed true for at least the time indicated by this object before the trigger becomes true and the trigger shall always become true if the condition is true for a duration equal to the value shown in this object plus 1 tenth of a second. 1.3.6.1.4.1.1206.4.1.1.7.9.7.1.5 " DEFVAL {0} ::= { recConfigEntry 5 } recConfigCompareOID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-write STATUS mandatory DESCRIPTION " This object contains the object identifier which references the value against which the comparison is made. If the recConfigMode is set to periodic, the value of this object shall be ignored. If the recConfigMode is set to greaterThanValue, smallerThanValue or hysteresisBound, this object is required to reference an object whose SYNTAX resolves to a ranged or unranged INTEGER. As with all other objects that are sub-ranged by a given implementation, an agent should return a badValue error if it receives a set command indicating a OID which is not supported by the implementation or which is not null. 1.3.6.1.4.1.1206.4.1.1.7.9.7.1.6 " DEFVAL {null} ::= { recConfigEntry 6 } recConfigRecordOID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-write STATUS mandatory DESCRIPTION "This object contains the object identifier which indicates what value to record in a recording (e.g., signal states). As with all other objects that are sub-ranged by a given implementation, an agent should return a badValue error if it receives a set command indicating a value which is not supported by the implementation. The valid value range of this object shall not include any values, other than null, that do not correspond to objects that may exist within the agent, although it may be further restricted. The valid value range of this object shall not include objects under the following nodes: Security - { nema transportation devices global security } CHAP - { nema transportation protocols layers chap } 1.3.6.1.4.1.1206.4.1.1.7.9.7.1.7 " DEFVAL {null} ::= { recConfigEntry 7 } recConfigTriggerPoint OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-write STATUS mandatory DESCRIPTION " This object contains the value of the recording trigger point in percent relative to the recConfigNumEntries. The device needs to collect pre-event records prior to the trigger occurring and ends the recording after recConfigNumEntries have been recorded. A value of zero (0) means to start the recording once the trigger condition occurs whereas a value of 100 means to stop the recording with the last record being the one collected immediately following the trigger condition occurring. If the trigger point is less than 100 then at least one record entry needs to occur after the trigger point. 1.3.6.1.4.1.1206.4.1.1.7.9.7.1.8 " DEFVAL {80} ::= { recConfigEntry 8 } recConfigSamplePeriod OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION " This object contains the sample period for recordings collected at specified by this configuration. The sample period is expressed in units of 0.1 milliseconds. Allowable sample periods are restricted to a value of zero (0) or (recMinSamplePeriod + recSamplePeriodResolution * n) where n is integer, 0 <= n, and n <= (recMaxSamplePeriod-recMinSamplePeriod)/recSamplePeriodResolution If the value is zero (0), then the samples are not collected on a periodic basis, but rather a new sample is collected whenever the value of the object specified by recConfigSampleOID changes (i.e. similar to event log ‘on-change’ mode). A set to any other value results in a badValue response. 1.3.6.1.4.1. 1206.4.1.1.7.9.7.1.9 " DEFVAL {1000} ::= { recConfigEntry 9 } recConfigSampleOID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-write STATUS mandatory DESCRIPTION " This object contains the object identifier which references the value against which the ‘on-change’ comparison is made. If recConfigSamplePeriod is non-zero, then the value of this object shall be ignored. As with all other objects that are sub-ranged by a given implementation, an agent should return a badValue error if it receives a set command indicating a OID which is not supported by the implementation or which is not null. 1.3.6.1.4.1.1206.4.1.1.7.9.7.1.10 " DEFVAL {null} ::= { recConfigEntry 10 } recConfigNumEntries OBJECT-TYPE SYNTAX INTEGER (0..4095) ACCESS read-write STATUS mandatory DESCRIPTION " This object contains the maximum number of records in a recording defined by this configuration. A recording which collects its full amount of pre-events and post events creates a recording of this number of entries. If this object is zero (0), then no recordings are created based on this configuration. Note: If one wants to use block objects to retrieve a recording, then one should consider that block starting index value is limited to the range 00..255, and the number of entries above 255 is dependent on the size of the recEntry and packet size limitations. 1.3.6.1.4.1.1206.4.1.1.7.9.7.1.11 " DEFVAL {100} ::= { recConfigEntry 11 } recConfigAction OBJECT-TYPE SYNTAX INTEGER { other (1), disabled (2), record (3) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object indicates what action shall take place when this configuration is triggered. other - indicates that the action is other than defined in this standard. disabled - no recording is created due to this configuration. record - a recording is created in the recording table when this configuration is triggered. 1.3.6.1.4.1.1206.4.1.1.7.9.7.1.12 " DEFVAL {disabled} ::= { recConfigEntry 12 } recConfigStatus OBJECT-TYPE SYNTAX INTEGER { other (1), disabled (2), record (3), error (4) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object indicates the current status of the configured recording. Upon setting any object in this row of the recConfigTable, the agent determines if the setting is valid, and sets this object to one of the following states: other indicates that the action is successfully set to a mode other than that defined in this standard disabled indicates that the action is set to disabled record indicates that the action is successfully set to the record state after passing consistency checks. error indicates that the requested action could not be implemented due to a consistency check 1.3.6.1.4.1.1206.4.1.1.7.9.7.1.13 " ::= { recConfigEntry 13 } maxRecordings OBJECT-TYPE SYNTAX INTEGER (1..65534) ACCESS read-only STATUS mandatory DESCRIPTION "The maximum, fixed number of rows that can be used within the recRecordingTable. Record 1.3.6.1.4.1.1206.4.1.1.7.9.8 " ::= { recMech 8} recRecordingTable OBJECT-TYPE SYNTAX SEQUENCE OF RecRecordingEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing information about Recordings both completed and in process. A request for an object from a row that has not been instantiated or has been cleared shall return a noSuchName error. dynamic 1.3.6.1.4.1.1206.4.1.1.7.9.9 " ::= { recMech 9 } recRecordingEntry OBJECT-TYPE SYNTAX RecRecordingEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This object defines an entry in the recording table 1.3.6.1.4.1.1206.4.1.1.7.9.9.1 " INDEX { recordingClass, recordingNumber } ::= { recRecordingTable 1 } RecRecordingEntry::= SEQUENCE { recordingClass INTEGER, recordingNumber INTEGER, recordingID INTEGER, recordingConfigID INTEGER, recordingTriggerTime OCTET STRING, recordingStatus INTEGER, recordingTriggerRecNum INTEGER, recordingNumEntries INTEGER } recordingClass OBJECT-TYPE SYNTAX INTEGER (1..254) ACCESS read-only STATUS mandatory DESCRIPTION "This object contains the class of the associated recording as defined in the recConfigTable. 1.3.6.1.4.1.1206.4.1.1.7.9.9.1.1 " ::= { recRecordingEntry 1 } recordingNumber OBJECT-TYPE SYNTAX INTEGER (1..254) ACCESS read-only STATUS mandatory DESCRIPTION "The recording number within this class for this recording. Recording numbers shall be assigned starting at 1 and shall increase to the value specified by the associated recClassLimit for the class associated with the rows. Recordings shall maintain a chronological ordering in the table, based on their recordingTriggerTime value, with the oldest recording of a class occupying the row with recordingNumber = 1, and subsequent recordings filling subsequent rows. This ordering shall be maintained for those rows still remaining when recordings are cleared. 1.3.6.1.4.1.1206.4.1.1.7.9.9.1.2 " ::= { recRecordingEntry 2 } recordingID OBJECT-TYPE SYNTAX INTEGER (1..65534) ACCESS read-only STATUS mandatory DESCRIPTION "This object contains the recording ID that is used as an index into recording entries table (recEntriesTable) when accessing record entries that belong to this recording. The recording ID is assigned to a recording upon creation of its first record entry and does not change throughout the life of the recording. The recording IDs are not necessarily assigned sequentially. 1.3.6.1.4.1.1206.4.1.1.7.9.9.1.3 " ::= { recRecordingEntry 3 } recordingConfigID OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This object contains the recording configuration ID (from the recConfigTable) that caused this table entry. It indicates the row in the recConfig table responsible for this recording entry. 1.3.6.1.4.1.1206.4.1.1.7.9.9.1.4 " ::= { recRecordingEntry 4 } recordingTriggerTime OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The time that the recording was triggered at. This object consists of a string of six (6) octets. The first four (4) octets reflect the value of globalTime when the recording was triggered. The last two (2) octets reflect the time in milliseconds the trigger occurred after the start of the second. The recording shall be detected and timestamped within one recSamplePeriodResolution unit of time from the recording being triggered. millisecond 1.3.6.1.4.1. 1206.4.1.1.7.9.9.1.5 " ::= { recRecordingEntry 5 } recordingStatus OBJECT-TYPE SYNTAX INTEGER { available (1), preevent (2), triggered (3), complete (4) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object reflects the state of the recording located in this row. Value Description available this row is available for a new recording to be initiated for this recording class. When a recording is cleared, the value is set to available preevent the recording defined by recConfigID is collecting pre-event record entries. Note: If the trigger point is set to zero (0) percent or the trigger condition is already satisfied when the recConfigID is configured, then the value transitions straight from available to triggered. triggered the recording defined by recConfigID has triggered and is now collecting post event records. If the trigger point was set to 100 percent, then the value transitions straight from preevent to complete. If a recording was triggered and the device experienced a power failure, then upon power restoration it shall change the value to complete. Triggered recordings shall survive a power outage. complete the recording defined by recConfigID is now complete (i.e. collected all of its post events) and ready for retrieval. Completed recordings shall survive a power outage. 1.3.6.1.4.1.1206.4.1.1.7.9.9.1.6 " ::= { recRecordingEntry 6 } recordingTriggerRecNum OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This object contains the record entry number of the trigger record entry. A value of zero (0) means that the recording has not triggered yet. 1.3.6.1.4.1.1206.4.1.1.7.9.9.1.7 " ::= { recRecordingEntry 7 } recordingNumEntries OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The current number of recording entries in this recording. A value of zero (0) is only valid if the recording is available for use. Note: A completed recording does not always have recConfigNumEntries record entries in it. 1.3.6.1.4.1.1206.4.1.1.7.9.9.1.8 " ::= { recRecordingEntry 8 } maxRecEntries OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The maximum, fixed number of rows that can be used within the recEntriesTable. Record 1.3.6.1.4.1.1206.4.1.1.7.9.10 " ::= { recMech 10} recEntriesTable OBJECT-TYPE SYNTAX SEQUENCE OF RecEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing the discrete Recording entry records. A request for an object from a row that has not been instantiated or has been cleared shall return a noSuchName error. dynamic 1.3.6.1.4.1.1206.4.1.1.7.9.11 " ::= { recMech 11 } recEntry OBJECT-TYPE SYNTAX RecEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This object defines an entry in the recording entry table. All entries within a recording shall be ordered chronologically from oldest to newest. 1.3.6.1.4.1.1206.4.1.1.7.9.11.1 " INDEX { recordingID, recEntryNumber } ::= { recEntriesTable 1 } RecEntry::= SEQUENCE { recEntryNumber INTEGER, recSampleTime OCTET STRING, recValue Opaque } recEntryNumber OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The entry number within this recording for this record. Entry numbers shall be assigned starting at 1 and shall increase up to the value specified by the associated recConfigNumEntries. A value of zero indicates that the row is unused (cleared). 1.3.6.1.4.1. 1206.4.1.1.7.9.11.1.1 " ::= { recEntry 1 } recSampleTime OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The time that the record entry was sampled at. This object consists of a string of six (6) octets. The first four (4) octets reflect the value of controllerLocalTime when the entry was sampled. The last two (2) octets reflect the time in milliseconds the sample occurred after the start of the second. The entry shall be collected within one recSamplePeriodResolution unit of time from the sample being triggered and timestamped with the time of collection millisecond 1.3.6.1.4.1.1206.4.1.1.7.9.11.1.2 " ::= { recEntry 2 } recValue OBJECT-TYPE SYNTAX Opaque ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is set to the BER encoding of the value referenced by the recConfigRecordOID of the associated recordingConfigID when the entry was collected. Its length is variable. The value shall not contain any padding characters either before or after the values. NOTE – Opaque objects are doubly wrapped. For SNMP operations, which use BER, this would be {type, length, {type, length, value}}. For example, a zero-length octet string, would be encoded in BER as 0x44 02 04 00. For STMP or SFMP operations, which use OER, this would be { length, {type, length, value}}. For example, the same example would be encoded in OER as 0x02 04 00. 1.3.6.1.4.1.1206.4.1.1.7.9.11.1.3 " ::= { recEntry 3 } numRecordings OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION " This object is a counter that gets incremented every time a recording is completed and shall initialize to zero at power up. The value shall roll over each time it exceeds the maximum of 65535. Recordings 1.3.6.1.4.1.1206.4.1.1.7.9.12 " ::= { recMech 12 } recClearClasses OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "This object commands the device to clear a recording class from recClassTable. A SET of zero has no effect on any recording classes. A SET = n, n <= maxRecClasses, shall cause recClassNumber = n to be deleted from the recClassTable and all related recording configurations, their recordings, their recording entries, their recording activities shall be deleted from the recConfigTable, recRecordingTable, and recEntriesTable respectively. A SET of 255 shall cause all entries in the recClassTable, recConfigTable, recRecordingTable, and recEntriesTable to be deleted. Upon performing the action requested, the device shall SET this object to zero (0). A GET shall always return zero (0). 1.3.6.1.4.1.1206.4.1.1.7.9.13 " ::= { recMech 13 } recClearConfigurations OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This object commands the device to clear a recording configuration from the recConfigTable. A SET of zero has no effect on any recording configurations. A SET = n, n <= maxRecConfigs, shall cause recConfigID = n to be deleted from the recRecordingTable and all related recordings, their recording entries, and their recording activities shall be deleted from the recRecordingTable and recEntriesTable respectively. A SET of n = 65535 shall cause all entries in the recConfigTable, recRecordingTable, and recEntriesTable to be deleted. Upon performing the action requested, the device shall SET this object to zero (0). A GET shall always return zero (0). 1.3.6.1.4.1.1206.4.1.1.7.9.14 " ::= { recMech 14 } recClearRecordingData OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This object commands the device to clear a recording from the recRecordingTable and recEntriesTable. A SET of zero has no effect on any recordings. A SET = n, n <= maxRecordings, shall cause recRecordingID = n to be deleted from the recRecordingTable and all record entries related to the recording to be deleted from recEntriesTable. A SET of n = 65535 shall cause all entries in both the recRecordingTable and recEntriesTable to be deleted. Note: a device shall immediately start collecting new pre-event records for all active recording configurations. Upon performing the action requested, the device shall SET this object to zero (0). A GET shall always return zero (0). 1.3.6.1.4.1.1206.4.1.1.7.9.15 " ::= { recMech 15 } END