-- OIDref derived MIB transcription. Original PDF: https://www.ntcip.org/file/2024/02/NTCIP-1202v03.35e-aspublished.pdf -- Publisher front matter and notices follow as comments. -- A Joint Standard of AASHTO, ITE, and NEMA -- -- -- -- -- NTCIP 1202 Version 03B -- -- National Transportation -- Communications for ITS Protocol -- -- Object Definitions for Actuated Signal -- Controllers (ASC) Interface -- -- Published in October 2023 -- -- -- -- -- Published by -- -- American Association of State Highway and Transportation Officials (AASHTO) -- 444 North Capitol Street, N.W., Suite 249 -- Washington, D.C. 20001 -- -- Institute of Transportation Engineers (ITE) -- 1627 Eye Street, N.W., Suite 550 -- Washington, D.C. 20006 -- -- National Electrical Manufacturers Association (NEMA) -- 1300 North 17th Street, Suite 900 -- Rosslyn, Virginia 22209-3801 -- -- NOTICES -- -- Copyright Notice -- --  2023 by the American Association of State Highway and Transportation Officials (AASHTO), the -- Institute of Transportation Engineers (ITE), and the National Electrical Manufacturers Association -- (NEMA). All intellectual property rights, including, but not limited to, the rights of reproduction, translation, -- and display are reserved under the laws of the United States of America, the Universal Copyright -- Convention, the Berne Convention, and the International and Pan American Copyright Conventions. -- Except as licensed or permitted, you may not copy these materials without prior written permission from -- AASHTO, ITE, or NEMA. Use of these materials does not give you any rights of ownership or claim of -- copyright in or to these materials. -- -- Visit www.ntcip.org for other copyright information, for instructions to request reprints of excerpts, and to -- request reproduction that is not granted below. -- -- -- PDF File License Agreement -- -- To the extent that these materials are distributed by AASHTO / ITE / NEMA in the form of an Adobe® -- Portable Document Format (PDF) electronic data file (the “PDF file”), AASHTO / ITE / NEMA authorizes -- each registered PDF file user to view, download, copy, or print the PDF file available from the authorized -- Web site, subject to the terms and conditions of this license agreement: -- -- a) you may download one copy of each PDF file for personal, noncommercial, and -- intraorganizational use only; -- b) ownership of the PDF file is not transferred to you; you are licensed to use the PDF file; -- c) you may make one more electronic copy of the PDF file, such as to a second hard drive or burn -- to a CD; -- d) you agree not to copy, distribute, or transfer the PDF file from that media to any other electronic -- media or device; -- e) you may print one paper copy of the PDF file; -- f) you may make one paper reproduction of the printed copy; -- g) any permitted copies of the PDF file must retain the copyright notice, and any other proprietary -- notices contained in the file; -- h) the PDF file license does not include (1) resale of the PDF file or copies, (2) republishing the -- content in compendiums or anthologies, (3) publishing excerpts in commercial publications or -- works for hire, (4) editing or modification of the PDF file except those portions as permitted, (5) -- posting on network servers or distribution by electronic mail or from electronic storage devices, -- and (6) translation to other languages or conversion to other electronic formats; -- i) other use of the PDF file and printed copy requires express, prior written consent. -- -- -- Data Dictionary and MIB Distribution Permission -- -- To the extent that these materials are distributed by AASHTO / ITE / NEMA in the form of a Data -- Dictionary (“DD”) or Management Information Base (“MIB”), AASHTO / ITE / NEMA extend the following -- permission: -- -- You may make or distribute unlimited copies, including derivative works, of the DD or MIB, including -- copies for commercial distribution, provided that: -- -- a) each copy you make or distribute includes the citation “Derived from NTCIP 0000 [insert the -- standard number]. Copyright by AASHTO / ITE / NEMA. Used by permission.”; -- -- b) the copies or derivative works are not made part of the standard publications or works offered by -- other standard developing organizations or publishers or as works-for-hire not associated with -- commercial hardware or software products intended for field implementation; -- c) use of the DD or MIB is restricted in that the SYNTAX fields may only be modified to define: 1) a -- more restrictive subrange; or 2) a subset of the standard enumerated values; or 3) a set of retired -- and defined enumerated values for systems supporting multiversion interoperability; -- d) the description field may be modified but only to the extent that: 1) the more restrictive subrange -- is defined; and 2) only those bit values or enumerated values that are supported are listed. -- [from 8002 A2 v04] -- -- These materials are delivered “AS IS” without any warranties as to their use or performance. -- -- AASHTO / ITE / NEMA and their suppliers do not warrant the performance or results you may -- obtain by using these materials. AASHTO / ITE / NEMA and their suppliers make no warranties, -- express or implied, as to noninfringement of third party rights, merchantability, or fitness for any -- particular purpose. In no event will AASHTO / ITE / NEMA or their suppliers be liable to you or any -- third party for any claim or for any consequential, incidental or special damages, including any -- lost profits or lost savings, arising from your reproduction or use of these materials, even if an -- AASHTO / ITE / NEMA representative has been advised of the possibility of such damages. -- -- Some states or jurisdictions do not allow the exclusion or limitation of incidental, consequential, or special -- damages, or the exclusion of implied warranties, so the above limitations may not apply to a given user. -- -- Use of these materials does not constitute an endorsement or affiliation by or between AASHTO, ITE, or -- NEMA and the user, the user's company, or the products and services of the user's company. -- -- If the user is unwilling to accept the foregoing restrictions, he or she should immediately return these -- materials. -- -- -- PRL and RTM Distribution Permission -- -- To the extent that these materials are distributed by AASHTO / ITE / NEMA in the form of a Protocol -- Requirements List (“PRL”) or a Requirements Traceability Matrix (“RTM”), AASHTO / ITE / NEMA extend -- the following permission: -- -- a) you may make or distribute unlimited copies, including derivative works of the PRL (then known -- as a Profile Implementation Conformance Statement (“PICS”)) or the RTM, provided that each -- copy you make or distribute contains the citation “Based on NTCIP 0000 [insert the standard -- number] PRL or RTM. Used by permission. Original text © AASHTO / ITE / NEMA.”; -- b) you may only modify the PRL or the RTM by adding: 1) text in the Project Requirements column, -- which is the only column that may be modified to show a product's implementation or the project- -- specific requirements; and/or 2) additional table columns or table rows that are clearly labeled as -- ADDITIONAL for project-unique or vendor-unique features; and -- c) if the PRL or RTM excerpt is made from an unapproved draft, add to the citation “PRL (or RTM) -- excerpted from a draft standard containing preliminary information that is subject to change.” -- -- This limited permission does not include reuse in works offered by other standards developing -- organizations or publishers, and does not include reuse in works-for-hire, compendiums, or electronic -- storage devices that are not associated with procurement documents, or commercial hardware, or -- commercial software products intended for field installation. -- -- A PRL is completed to indicate the features that are supported in an implementation. Visit www.ntcip.org -- for information on electronic copies of the MIBs, PRLs, and RTMs. -- -- TRF Distribution Permission -- -- A Testing Requirements Form (“TRF”) may be a Testing Requirements Traceability Table and/or Test -- Procedures. To the extent that these materials are distributed by AASHTO / ITE / NEMA in the form of a -- TRF, AASHTO / ITE / NEMA extend the following permission: -- -- a) you may make and/or distribute unlimited electronic or hard copies, including derivative works of -- the TRF, provided that each copy you make and/or distribute contains the citation “Based on -- NTCIP 0000 [insert the standard number] TRF. Used by permission. Original text © AASHTO / -- ITE / NEMA.”; -- b) you may not modify the logical flow of any test procedure, without clearly noting and marking any -- such modification; and -- c) if the TRF excerpt is made from an unapproved draft, add to the citation “TRF excerpted from a -- draft standard containing preliminary information that is subject to change.” -- -- -- Content and Liability Disclaimer -- -- The information in this publication was considered technically sound by the consensus of persons -- engaged in the development and approval of the document at the time it was developed. Consensus -- does not necessarily mean that there is unanimous agreement among every person participating in the -- development of this document. -- -- AASHTO, ITE, and NEMA standards and guideline publications, of which the document contained herein -- is one, are developed through a voluntary consensus standards development process. This process -- brings together volunteers and seeks out the views of persons who have an interest in the topic covered -- by this publication. While AASHTO, ITE, and NEMA administer the process and establish rules to -- promote fairness in the development of consensus, they do not write the document and they do not -- independently test, evaluate, or verify the accuracy or completeness of any information or the soundness -- of any judgments contained in their standards and guideline publications. -- -- AASHTO, ITE, and NEMA disclaim liability for any personal injury, property, or other damages of any -- nature whatsoever, whether special, indirect, consequential, or compensatory, directly or indirectly -- resulting from the publication, use of, application, or reliance on this document. AASHTO, ITE, and NEMA -- disclaim and make no guaranty or warranty, express or implied, as to the accuracy or completeness of -- any information published herein, and disclaims and makes no warranty that the information in this -- document will fulfill any of your particular purposes or needs. AASHTO, ITE, and NEMA do not undertake -- to guarantee the performance of any individual manufacturer or seller's products or services by virtue of -- this standard or guide. -- -- In publishing and making this document available, AASHTO, ITE, and NEMA are not undertaking to -- render professional or other services for or on behalf of any person or entity, nor are AASHTO, ITE, and -- NEMA undertaking to perform any duty owed by any person or entity to someone else. Anyone using this -- document should rely on his or her own independent judgment or, as appropriate, seek the advice of a -- competent professional in determining the exercise of reasonable care in any given circumstances. -- Information and other standards on the topic covered by this publication may be available from other -- sources, which the user may wish to consult for additional views or information not covered by this -- publication. -- -- AASHTO, ITE, and NEMA have no power, nor do they undertake to police or enforce compliance with the -- contents of this document. AASHTO, ITE, and NEMA do not certify, test, or inspect products, designs, or -- installations for safety or health purposes. Any certification or other statement of compliance with any -- health or safety-related information in this document shall not be attributable to AASHTO, ITE, or NEMA -- and is solely the responsibility of the certifier or maker of the statement. -- -- Trademark Notice -- -- NTCIP is a trademark of AASHTO / ITE / NEMA. All other marks mentioned in this standard are the -- trademarks of their respective owners. -- -- -- -- NTCIP 1202 v03B.35 -- Page i -- -- -- Acknowledgments -- -- NTCIP 1202 v03 was prepared by the NTCIP Actuated Signal Controller Working Group (ASC WG), -- which is a subdivision of the Joint Committee on the NTCIP. The NTCIP Joint Committee is organized -- under a Memorandum of Understanding among the American Association of State Highway and -- Transportation Officials (AASHTO), the Institute of Transportation Engineers (ITE), and the National -- Electrical Manufacturers Association (NEMA). The NTCIP Joint Committee consists of six representatives -- from each of the standards organizations, and provides guidance for NTCIP development. -- -- When NTCIP 1202 v03 was prepared, the following individuals were voting (indicated by an asterisk) or -- alternate voting members of the NTCIP ASC WG: -- -- -- • City of Anaheim, John Thai* (Co-Chair) • Oregon Department of Transportation, -- • California Department of Transportation, Christopher Primm*, Roger Boettcher, -- Mike Robinson*, Jay Schultz Doug Spencer -- • Econolite Control Products, Inc., Dustin • Pillar Consulting, Ralph Boaz* -- DeVoe*, Dan Brandesky • Q-Free, Doug Tarico* (Co-Chair), -- • Florida Department of Transportation, Douglas Crawford -- Matthew DeWitt*, Jeffrey Morgan, Derek • Texas A&M University (TTI), Kevin -- Vollmer Balke*, Hassan Charara, Srinivasa -- • Minnesota Department of Sunkari -- Transportation, Ray Starr*, Terry • TransCore ITS, Robert Rausch*, David -- Haukom, Peter Skewers Benevelli, Keith Patton -- • Nissan Motor Co., Roy Goudy* • Yunex Traffic, Jonathan Grant*, Dave -- Miller, Iouri Nemirovski -- -- Observing members include: -- -- • Applied Information, Inc., Bryan Mulligan, • Econolite, Gary Duncan, Barry Einsig, Eric -- Walt Townsend Raamot -- • Consensus Systems Technologies, Patrick • McCain Inc., Donald Maas Jr., Matt Zinn, -- Chan, AJ Lahiri Mark Simpson -- • Eberle Design, Inc., Scott Evans • Southwest Research Institute, Cameron -- Mott -- -- Additional stakeholders who provided input or monitored development include: -- -- • Adaptive Solutions, James Kinnard • GreenFactor, Canny Quach -- • Arcadis U.S., Inc., David Ritchie • Gridaptive, Jim Frazer -- • Battelle, Jeffrey Arch, Greg Zink • HNTB, Stephen Novosad -- • Caliper Corporation, Wuping Xin • Intsignia, Craig Hinners -- • CAMP, Jay Parikh • Iteris, Tom Lusco -- • City of Rosevell, Mojtaba Mohammadi • Jacobs Engineering, Diederick VanDillen -- • Cubic, Shaun Alford, Jeff Cornelius • Kapsch, Joerg “Nu” Rosenbohm -- • Danlaw, Mostafa Kassem • Kimley-Horn, Bob Barkley -- • DENSO, Bryan Wells • Maricopa County Department of -- • Diablo Controls, Inc., Allen Jacobs Transportation, April Wire, Jarod Carrell -- • DKS & Associates, Alan Clelland • Michigan Department of Transportation, -- • Georgia Department of Transportation, Bashir Choudry -- Alan Davis • Mid-America Regional Council, Ray Webb -- • Gewalt-Hamilton Associates, Milan Patel • Miovision, Jan Bergstrom, Dave Hillis, Greg -- • Global Traffic Technologies, LLC, Christian Barlow, Brian Hoeft -- Kulus • Mixon Hill, Lee Mixon, Christpher Poe -- -- -- © 2023 AASHTO / ITE / NEMA Do Not Copy Without Written Permission -- -- NTCIP 1202 v03B.35 -- Page ii -- -- • New Jersey DOT, Jeevanjot Singh • SANDAG, Peter Thompson -- • New York City DOT, Rami Khashashina, • SCA Transportation, Soan Chau -- Mohamad Talas • SCSC, David Kelley -- • Noblis, Justin Anderson • Seattle DOT, Michael Mullen -- • North Carolina DOT, Greg Fuller • Trevilon Corp., Kenneth Vaughn -- • OmniAir, Randy Roebuck • Triunity Engineering, Israel Lopez -- • Oriux, Ray Deer, Brian Bojorquez, Joe • The University of Arizona, Larry Head -- Socci • UTA, Taylor Li -- • Overland Park, KS, Shawn Gotfredson • Utah Department of Transportation, Chuck -- • Oz Engineering, Tomas Guerra Felice, Shane Johnson, Matt Luker -- • Panasonic, Michael Stelts • WSP, Christopher Toth, Thomas Timcho, -- • Parsons, Jon Wyatt, Dmitri Khijniak Erica Toussant, Nora Wisor, Anthony -- • PR Olson Associates, Paul Olson Gasiorowski, Eric Gionet -- • SAE International, Keith Wilson -- -- Beth Ellen Dibeler, Richard Downs, Meredith Emory, Christopher Flores, Leslie Hart, Chris Mysz, Ali Sohi, -- Gabriel Szyrnski, Mike Wasielewski, Andy Zhang -- -- In addition to the many volunteer efforts, recognition is also given to those organizations that supported -- the effort by providing funding: -- -- • U.S. Department of Transportation -- -- -- -- -- Do Not Copy Without Written Permission © 2023 AASHTO / ITE / NEMA NTCIP1202-v03 DEFINITIONS ::= BEGIN -- the following OBJECT IDENTIFIERS are used in the ASC MIB: IMPORTS IpAddress, Counter, null FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 DisplayString, ifIndex FROM RFC1213-MIB OwnerString, OerString, devices FROM NTCIP8004v02; asc OBJECT IDENTIFIER ::= { devices 1 } phase OBJECT IDENTIFIER ::= { asc 1 } -- This node shall contain objects that configure, monitor or -- control phase functions for this device. maxPhases OBJECT-TYPE SYNTAX INTEGER (2..255) ACCESS read-only STATUS mandatory DESCRIPTION " The Maximum Number of Phases this Controller Unit supports. This object indicates the maximum rows which shall appear in the phaseTable object. 1.3.6.1.4.1.1206.4.2.1.1.1 S phase" ::= { phase 1 } phaseTable OBJECT-TYPE SYNTAX SEQUENCE OF PhaseEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table containing Controller Unit phase parameters. The number of rows in this table is equal to the maxPhases object. static 1.3.6.1.4.1.1206.4.2.1.1.2" ::= { phase 2 } phaseEntry OBJECT-TYPE SYNTAX PhaseEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Parameters for a specific Controller Unit phase. 1.3.6.1.4.1.1206.4.2.1.1.2.1 " INDEX { phaseNumber } ::= { phaseTable 1 } PhaseEntry ::= SEQUENCE { phaseNumber INTEGER, phaseWalk INTEGER, phasePedestrianClear INTEGER, phaseMinimumGreen INTEGER, phasePassage INTEGER, phaseMaximum1 INTEGER, phaseMaximum2 INTEGER, phaseYellowChange INTEGER, phaseRedClear INTEGER, phaseRedRevert INTEGER, phaseAddedInitial INTEGER, phaseMaximumInitial INTEGER, phaseTimeBeforeReduction INTEGER, phaseCarsBeforeReduction INTEGER, phaseTimeToReduce INTEGER, phaseReduceBy INTEGER, phaseMinimumGap INTEGER, phaseDynamicMaxLimit INTEGER, phaseDynamicMaxStep INTEGER, phaseStartup INTEGER, phaseOptions INTEGER, phaseRing INTEGER, phaseConcurrency OCTET STRING, phaseMaximum3 INTEGER, phaseYellowandRedChangeTimeBeforeEndPedClear INTEGER, phasePedWalkService INTEGER, phaseDontWalkRevert INTEGER, phasePedAlternateClearance INTEGER, phasePedAlternateWalk INTEGER, phasePedAdvanceWalkTime INTEGER, phasePedDelayTime INTEGER, phaseAdvWarnGrnStartTime INTEGER, phaseAdvWarnRedStartTime INTEGER, phaseAltMinTimeTransition INTEGER } phaseNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The phase number for objects in this row. This value shall not exceed the maxPhases object value. 1.3.6.1.4.1.1206.4.2.1.1.2.1.1 S phase" ::= { phaseEntry 1 } phaseWalk OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Phase Walk Parameter in seconds. This shall control the amount of time the Walk indication shall be displayed. This parameter shall be used regardless whether the pedestrian indication associated with this phase is for a ped- only phase or for a pedestrian indication that runs parallel to a vehicle phase. 1.3.6.1.4.1.1206.4.2.1.1.2.1.2 P second" REFERENCE "NEMA TS 2 Clause 3.5.3.1 and 3.5.3.2.2.a" ::= { phaseEntry 2 } phasePedestrianClear OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Phase Pedestrian Clear Parameter in seconds. This shall control the duration of the Pedestrian Clearance output (if present) and the flashing period of the Don't Walk output. This parameter shall be used regardless whether the pedestrian indication associated with this phase is for a ped-only phase or for a pedestrian indication that runs parallel to a vehicle phase. 1.3.6.1.4.1.1206.4.2.1.1.2.1.3 P second" REFERENCE "NEMA TS 2 Clause 3.5.3.1 and 3.5.3.2.2.b" ::= { phaseEntry 3 } phaseMinimumGreen OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Phase Minimum Green Parameter in seconds (NEMA TS 2 range: 1-255 sec). The first timed portion of the Green interval which may be set in consideration of the storage of vehicles between the zone of detection for the approach vehicle detector(s) and the stop line. 1.3.6.1.4.1.1206.4.2.1.1.2.1.4 P second" REFERENCE "NEMA TS 2 Clause 3.5.3.1 and 3.5.3.2.1.a.(1)" ::= { phaseEntry 4 } phasePassage OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Phase Passage Parameter in tenth seconds (0- 25.5 sec). Passage Time, Vehicle Interval, Preset Gap, Vehicle Extension: the extensible portion of the Green shall be a function of vehicle actuations that occur during the Green interval. The phase shall remain in the extensible portion of the Green interval as long as the passage timer is not timed out. The timing of this portion of the green interval shall be reset with each subsequent vehicle actuation and shall not commence to time again until the vehicle actuation is removed or the maximum green timer has expired. 1.3.6.1.4.1.1206.4.2.1.1.2.1.5 P tenth second" REFERENCE "NEMA TS 2 Clause 3.5.3.1 and 3.5.3.2.1.a.(2)" ::= { phaseEntry 5 } phaseMaximum1 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Phase Maximum 1 Parameter in seconds (NEMA TS 2 range: 1-255 sec). This time setting shall determine the maximum length of time this phase may be held in Green in the presence of a serviceable conflicting call. In the absence of a serviceable conflicting call the Maximum Green timer shall be held reset unless Max Vehicle Recall is enabled for this phase. This is the default maximum value to use. It may be overridden via an external input, coordMaximumMode or other method. 1.3.6.1.4.1.1206.4.2.1.1.2.1.6 P second" REFERENCE "NEMA TS 2 Clause 3.5.3.1, 3.5.3.2.1.a.(3) and 3.5.3.5" ::= { phaseEntry 6 } phaseMaximum2 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Phase Maximum 2 Parameter in seconds (NEMA TS 2 range: 1-255 sec). This time setting shall determine the maximum length of time this phase may be held in Green in the presence of a serviceable conflicting call. In the absence of a serviceable conflicting call the Maximum Green timer shall be held reset unless Max Vehicle Recall is enabled for this phase. This may be implemented as the max green timer via an external input, coordMaximumMode or other method. 1.3.6.1.4.1.1206.4.2.1.1.2.1.7 P second" REFERENCE "NEMA TS 2 Clause 3.5.3.1, 3.5.3.2.1.a.(3), 3.5.3.5 and 3.5.4.1 (7)" ::= { phaseEntry 7 } phaseYellowChange OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Phase Yellow Change Parameter in tenth seconds (NEMA TS 2 range: 3-25.5 sec). Following the Green interval of each phase the CU shall provide a Yellow Change interval which is timed according to the Yellow Change parameter for that phase. 1.3.6.1.4.1.1206.4.2.1.1.2.1.8 P tenth second" REFERENCE "NEMA TS 2 Clause 3.5.3.1 and 3.5.3.2.5.a" ::= { phaseEntry 8 } phaseRedClear OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Phase Red Clearance Parameter in tenth seconds (0-25.5 sec).Following the Yellow Change interval for each phase, the CU shall provide a Red Clearance interval which is timed according to the Red Clearance parameter for that phase. 1.3.6.1.4.1.1206.4.2.1.1.2.1.9 P tenth second" REFERENCE "NEMA TS 2 Clause 3.5.3.1 and 3.5.3.2.5.b" ::= { phaseEntry 9 } phaseRedRevert OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Red revert time parameter in tenth seconds. A minimum Red indication to be timed following the Yellow Change interval and prior to the next display of Green on the same signal output driver group. The unitRedRevert parameter shall act as a minimum red revert time for all signal displays. The phaseRedRevert parameter may increase the red revert time for a specific phase. If the phaseRedRevert parameter is less than the unitRedRevert the unitRedRevert time shall be used. 1.3.6.1.4.1.1206.4.2.1.1.2.1.10 P tenth second" ::= { phaseEntry 10 } phaseAddedInitial OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Phase Added Initial Parameter in tenths of seconds (0-25.5 sec). Added Initial parameter (Seconds / Actuation) shall determine the time by which the variable initial time period will be increased from zero with each vehicle actuation received during the associated phase Yellow and Red intervals. 1.3.6.1.4.1.1206.4.2.1.1.2.1.11 P tenth second" REFERENCE "NEMA TS 2 Clause 3.5.3.1 and 3.5.3.2.1.b.(1).(b)" ::= { phaseEntry 11 } phaseMaximumInitial OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Phase Maximum Initial Parameter in seconds (0-255 sec). The maximum value of the variable initial timing period. Variable Initial timing shall equal the lesser of [added initial (seconds / actuation) * number of actuations] or [ Max Initial ]. The variable initial time shall not be less than Minimum Green. 1.3.6.1.4.1.1206.4.2.1.1.2.1.12 P second" REFERENCE "NEMA TS 2 Clause 3.5.3.2.1.b.(1).(c)" ::= { phaseEntry 12 } phaseTimeBeforeReduction OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Phase Time Before Reduction (TBR) Parameter in seconds (0-255 sec). The Time Before Reduction period shall begin when the phase is Green and there is a serviceable conflicting call. If the serviceable conflicting call is removed before completion of this time (or time to reduce), the timer shall reset. Upon completion of the TBR period or the CarsBeforeReduction (CBR) parameter is satisfied, whichever occurs first, the linear reduction of the allowable gap from the Passage Time shall begin. 1.3.6.1.4.1.1206.4.2.1.1.2.1.13 P second" REFERENCE "NEMA TS 2 Clause 3.5.3.1 and 3.5.3.2.1.b.(2)" ::= { phaseEntry 13 } phaseCarsBeforeReduction OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Phase Cars Before Reduction (CBR) Parameter (0-255 vehicles). When the phase is Green and the sum of the cars waiting (vehicle actuations during Yellow & Red intervals) on serviceable conflicting phases equals or exceeds the CBR parameter or the Time Before Reduction (TBR) parameter is satisfied, whichever occurs first, the linear reduction of the allowable gap from the Passage Time shall begin. 1.3.6.1.4.1.1206.4.2.1.1.2.1.14 P vehicle" ::= { phaseEntry 14 } phaseTimeToReduce OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Phase Time To Reduce Parameter in seconds (0- 255 sec). This parameter shall control the rate of reduction of the allowable gap between the Passage Time and Minimum Gap setting. 1.3.6.1.4.1.1206.4.2.1.1.2.1.15 P second" REFERENCE "NEMA TS 2 Clause 3.5.3.1 and 3.5.3.2.1.b.(2)" ::= { phaseEntry 15 } phaseReduceBy OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " This object may be used for volume density gap reduction as an alternate to the linear reduction defined by NEMA TS 1 and TS 2. It contains the tenths of seconds to reduce the gap by (0.0 - 25.5 seconds). The frequency of reduction shall produce the Minimum Gap after a time equal to the 'phaseTimeToReduce' object. 1.3.6.1.4.1.1206.4.2.1.1.2.1.16 P tenth second" ::= { phaseEntry 16 } phaseMinimumGap OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Phase Minimum Gap Parameter in tenth seconds (0-25.5 sec). The reduction of the allowable gap shall continue until the gap reaches a value equal to or less than the minimum gap as set on the Minimum Gap control after which the allowable gap shall remain fixed at the values set on the Minimum Gap control. 1.3.6.1.4.1.1206.4.2.1.1.2.1.17 P tenth second" REFERENCE "NEMA TS 2 Clause 3.5.3.1 and 3.5.3.2.1.b.(2)" ::= { phaseEntry 17 } phaseDynamicMaxLimit OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " This object shall determine either the upper or lower limit of the running max in seconds (0-255 sec) during dynamic max operation. The normal maximum (i.e. Max1, Max2, etc.) shall determine the other limit as follows: When dynamicMaxLimit is larger than the normal maximum, it shall become the upper limit. When dynamicMaxLimit is smaller than the normal maximum, it shall become the lower limit. Setting dynamicMaxLimit greater than zero enables dynamic max operation with the normal maximum used as the initial maximum setting. See dynamicMaxStep for details on dynamic max operation. Maximum recall or a failed detector that is assigned to the associated phase shall disable dynamic max operation for the phase. 1.3.6.1.4.1.1206.4.2.1.1.2.1.18 P second" ::= { phaseEntry 18 } phaseDynamicMaxStep OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " This object shall determine the automatic adjustment to the running max in tenth seconds (0-25.5) When a phase maxes out twice in a row, and on each successive max out thereafter, one dynamic max step value shall be added to the running max until such addition would mean the running max was greater than the larger of normal max or dynamic max limit. When a phase gaps out twice in a row, and on each successive gap out thereafter, one dynamic max step value shall be subtracted from the running max until such subtraction would mean the running max was less than the smaller of the normal max or the dynamic max limit. If a phase gaps out in one cycle and maxes out in the next cycle, or vice versa, the running max will not change. 1.3.6.1.4.1.1206.4.2.1.1.2.1.19 P tenth second" ::= { phaseEntry 19 } phaseStartup OBJECT-TYPE SYNTAX INTEGER { other (1), phaseNotOn (2), greenWalk (3), greenNoWalk (4), yellowChange (5), redClear (6)} ACCESS read-write STATUS mandatory DESCRIPTION " The Phase Startup parameter is an enumerated integer which selects the startup state for each phase after restoration of a defined power interruption or activation of the external start input. The following entries are defined: other: this phase is not enabled (phaseOptions bit 0=0 or phaseRing=0) or initializes in a state not defined by this standard. phaseNotOn: this phase initializes in a Red state (the phase is not active and no intervals are timing). greenWalk: this phase initializes at the beginning of the minimum green and walk timing intervals. greenNoWalk: this phase initializes at the beginning of the minimum green timing interval. yellowChange: this phase initializes at the beginning of the Yellow Change interval. redClear: this phase initializes at the beginning of the Red Clearance interval. 1.3.6.1.4.1.1206.4.2.1.1.2.1.20 P2" REFERENCE "NEMA TS 2 Clause 3.5.5.1 and 3.5.5.12" ::= { phaseEntry 20 } phaseOptions OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION " Optional phase functions ( 0 = False/ Disabled, 1 = True/Enabled) Bit 15: AddedInitialCalculation - If set (1) the CU shall compare counts from all associated AddedInitial detectors and use the largest count value for the calculations. If clear (0) the CU shall sum all associated AddedInitial detector counts and use this sum for the calculations. The ability to modify the setting of this bit is optional. Bit 14: Conditional Service Enable - in multi-ring configurations when set to 1 causes a gapped/maxed phase to conditionally service a preceding actuated vehicle phase when sufficient time remains before max time out of the phase(s) not prepared to terminate. Support is optional. REFERENCE NEMA TS 2 Clause 3.5.3.9 Bit 13: Actuated Rest In Walk - when set to 1 causes an actuated phase to rest in Walk when there is no serviceable conflicting call at the end of Walk Timing. Bit 12: Guaranteed Passage - when set to 1 enables an actuated phase operating in volume density mode (using gap reduction) to retain the right of way for the unexpired portion of the Passage time following the decision to terminate the green due to a reduced gap. Support is optional Bit 11: Simultaneous Gap Disable - in multi-ring configurations when set to 1 disables a gapped out phase from reverting to the extensible portion. Support is optional REFERENCE NEMA TS 2 Clause 3.5.5.3 Bit 10: Dual Entry Phase - in multi-ring configurations when set to 1 causes the phase to become active upon entry into a concurrency group (crossing a barrier) when no calls exist in its ring within its concurrency group. REFERENCE NEMA TS 2 Clause 3.5.5.3 Bit 9: Soft Vehicle Recall - when set to 1 causes a call on a phase when all conflicting phases are in green dwell or red dwell and there are no serviceable conflicting calls. Support is optional. Bit 8: Ped. Recall - when set to 1 causes a recurring pedestrian demand which shall function in the same manner as an external pedestrian call except that it shall not recycle the pedestrian service until a conflicting phase is serviced. REFERENCE NEMA TS 2 Clause 3.5.3.7 Bit 7: Max Vehicle Recall - when set to 1 causes a call on a phase such that the timing of the Green interval for that phase shall be extended to Maximum Green time. REFERENCE NEMA TS 2 Clause 3.5.3.5 Bit 6: Min. Vehicle Recall - when set to 1 causes recurring demand for vehicle service on the phase when that phase is not in its Green interval. REFERENCE NEMA TS 2 Clause 3.5.3.6 Bit 5: Non Lock Detector Memory - when set to 0 will cause the call to be locked at the beginning of the yellow interval. When set to 1 call locking will depend on the detectorOptions object. REFERENCE NEMA TS 2 Clause 3.5.3.4 Bit 4: Non-Actuated 2 - when set to 1 causes a phase to respond to the Call To Non-Actuated 2 input (if present) or other method. Support is optional REFERENCE NEMA TS 2 Clause 3.5.5.5.8 Bit 3: Non-Actuated 1 - when set to 1 causes a phase to respond to the Call To Non-Actuated 1 input (if present) or other method. Support is optional REFERENCE NEMA TS 2 Clause 3.5.5.5.8 Bit 2: Automatic Flash Exit Phase - The CU shall move immediately to the beginning of the phase(s) programmed as Exit Phase(s) when Automatic Flash terminates. Support is optional REFERENCE NEMA TS 2 Clause 3.9.1.2.1 Bit 1: Automatic Flash Entry Phase - When Automatic Flash is called, the CU shall service the Entry Phase(s), clear to an All Red, then initiate flashing operation. Support is optional. REFERENCE NEMA TS 2 Clause 3.9.1.2.1 Bit 0: Enabled Phase - provide a means to define whether this phase is used in the current configuration. A disabled phase shall not provide any outputs nor respond to any phase inputs. The object phaseRing = 0 has the same effect. 1.3.6.1.4.1.1206.4.2.1.1.2.1.21 P2" ::= { phaseEntry 21 } phaseRing OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Phase ring number (1..maxRings) that identified the ring which contains the associated phase. This value must not exceed the maxRings object value. If the ring number is zero, the phase is disabled (phaseOptions Bit 0 = 0 has the same effect). 1.3.6.1.4.1.1206.4.2.1.1.2.1.22 P2 ring" ::= { phaseEntry 22 } phaseConcurrency OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION " Each octet contains a phase number (binary value) that may run concurrently with the associated phase. Phases that are contained in the same ring may NOT run concurrently. 1.3.6.1.4.1.1206.4.2.1.1.2.1.23 P2" ::= { phaseEntry 23 } phaseMaximum3 OBJECT-TYPE SYNTAX INTEGER (0..6000) ACCESS read-write STATUS mandatory DESCRIPTION " Phase Maximum 3 Parameter in seconds. This time setting shall determine the maximum length of time this phase may be held in Green in the presence of a serviceable conflicting call. In the absence of a serviceable conflicting call the Maximum Green timer shall be held reset unless Max Vehicle Recall is enabled for this phase. This may be implemented as the max green timer via an external input, coordMaximumMode or other method. 1.3.6.1.4.1.1206.4.2.1.1.2.1.24 P second" ::= { phaseEntry 24 } phaseYellowandRedChangeTimeBeforeEndPedClear OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " The amount of time that the pedestrian clearance may extend into the vehicle clearance time (yellow and red) for a phase. This parameter is expressed in 0.1 second increments ranging from 0.0 to 25.5 seconds. 1.3.6.1.4.1.1206.4.2.1.1.2.1.25 P tenth second" ::= { phaseEntry 25 } phasePedWalkService OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION " This parameter indicates whether and how many times this phase is allowed to recycle the pedestrian movement during a cycle. This parameter is used for ped-only, signalized intersections (mostly mid-block) that are within a coordinated roadway. If set to '1', no recycle is allowed and the pedestrian movement can be shown only up to once. If set to '2', the pedestrian movement can be shown up to twice during a cycle, etc. 1.3.6.1.4.1.1206.4.2.1.1.2.1.26 P" ::= { phaseEntry 26 } phaseDontWalkRevert OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Dont Walk revert time parameter in tenth seconds. A minimum Dont Walk indication to be timed following the pedestrian clearance interval prior to the next Walk indication on the same signal output driver group. 1.3.6.1.4.1.1206.4.2.1.1.2.1.27 P tenth second" ::= { phaseEntry 27 } phasePedAlternateClearance OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " An alternate (replacement) time, in seconds, for the duration of the pedestrian clearance output (if present) and the flashing period of the dont walk output. This parameter may be used for a parallel pedestrian indication in conjunction with a vehicle phase or with a ped-only phase. 1.3.6.1.4.1.1206.4.2.1.1.2.1.28 P second" ::= { phaseEntry 28 } phasePedAlternateWalk OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " An alternate (replacement) time, in seconds, for a pedestrian walk. This shall control the amount of time the Walk indication shall be displayed. This parameter may be used for a parallel pedestrian indication in conjunction with a vehicle phase or with a ped-only phase. 1.3.6.1.4.1.1206.4.2.1.1.2.1.29 P second" ::= { phaseEntry 29 } phasePedAdvanceWalkTime OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " The amount of time, in tenths of a second from 0 to 25.5 seconds, that the vehicle phase's parallel pedestrian Walk indication starts before the start of the green indication of the vehicle phase. A value of 12.7 seconds indicates the pedestrian WALK indication starts 12.7 seconds before the GREEN indication of the vehicle phase. The actual offset used between the start of the pedestrian Walk indication and the start of the green indication of the vehicle phase is the sum of this object value plus the value in the phasePedDelayTime. 1.3.6.1.4.1.1206.4.2.1.1.2.1.30 P tenth second" DEFVAL { 0 } ::= { phaseEntry 30 } phasePedDelayTime OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " The amount of time, in tenths of a second from 0 to 25.5 seconds, that the vehicle phase's parallel pedestrian Walk indication starts after the start of the green indication of the vehicle phase. A value of 12.7 indicates the pedestrian WALK indication starts 12.7 seconds after the GREEN indication of the vehicle phase. The actual offset used between the start of the pedestrian Walk indication and the start of the green indication of the vehicle phase is the sum of this object value plus the value in the phasePedAdvanceWalkTime. 1.3.6.1.4.1.1206.4.2.1.1.2.1.31 P tenth second" DEFVAL { 0 } ::= { phaseEntry 31 } phaseAdvWarnGrnStartTime OBJECT-TYPE SYNTAX INTEGER (0..128) ACCESS read-write STATUS mandatory DESCRIPTION " The amount of time, in tenths of a second for a period of 0.0 to 12.8 seconds, that an advanced warning signal indication is displayed before the start of phase Green. The warning signal is placed upstream of the phase's approach and indicates that the phase's Green indication is about to start or has started. The value of this object should not exceed the total amount of clearance time of the phase(s) that is being terminated prior to the start of this phase. Note: The Advanced Warning Green terminates at the end of the green. 1.3.6.1.4.1.1206.4.2.1.1.2.1.32 P tenth second" ::= { phaseEntry 32 } phaseAdvWarnRedStartTime OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " The amount of time, in tenths of a second for a range of 0.0 to 25.5 seconds, prior to the start of the phase's RED indication that an advanced warning signal, placed upstream of the phase's approach, turns on. Note: The Advanced Warning Red terminates at the end of Red. 1.3.6.1.4.1.1206.4.2.1.1.2.1.33 P tenth second" ::= { phaseEntry 33 } phaseAltMinTimeTransition OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " This object indicates the alternate minimum green time that is used during transitions, in seconds from 1 to 255 seconds. This object can be applied during transitions or signal priority. A value of 0 indicates that this object is not used during transitions. The alternate minimum green cannot be less than phaseMinimumGreen for this phase. 1.3.6.1.4.1.1206.4.2.1.1.2.1.34 P second" DEFVAL { 0 } ::= { phaseEntry 34 } maxPhaseGroups OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The Maximum Number of Phase Groups (8 Phases per group) this Controller Unit supports. This value is equal to TRUNCATE [(maxPhases + 7) / 8]. This object indicates the maximum rows which shall appear in the phaseStatusGroupTable and phaseControlGroupTable. 1.3.6.1.4.1.1206.4.2.1.1.3 S group" ::= { phase 3 } phaseStatusGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF PhaseStatusGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table containing Controller Unit Phase Output (Red, Yellow, & Green) and Call (vehicle & pedestrian) status in groups of eight Phases. The number of rows in this table is equal to the maxPhaseGroups object. static 1.3.6.1.4.1.1206.4.2.1.1.4" ::= { phase 4 } phaseStatusGroupEntry OBJECT-TYPE SYNTAX PhaseStatusGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Red, Yellow, & Green Output Status and Vehicle and Pedestrian Call for eight Controller Unit Phases. 1.3.6.1.4.1.1206.4.2.1.1.4.1" INDEX { phaseStatusGroupNumber } ::= { phaseStatusGroupTable 1 } PhaseStatusGroupEntry ::= SEQUENCE { phaseStatusGroupNumber INTEGER, phaseStatusGroupReds INTEGER, phaseStatusGroupYellows INTEGER, phaseStatusGroupGreens INTEGER, phaseStatusGroupDontWalks INTEGER, phaseStatusGroupPedClears INTEGER, phaseStatusGroupWalks INTEGER, phaseStatusGroupVehCalls INTEGER, phaseStatusGroupPedCalls INTEGER, phaseStatusGroupPhaseOns INTEGER, phaseStatusGroupPhaseNexts INTEGER } phaseStatusGroupNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The Phase Status Group number for objects in this row. This value shall not exceed the maxPhaseGroups object value. 1.3.6.1.4.1.1206.4.2.1.1.4.1.1 S group" ::= { phaseStatusGroupEntry 1 } phaseStatusGroupReds OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " Phase Red Output Status Mask, when a bit = 1, the Phase Red is currently active. When a bit = 0, the Phase Red is NOT currently active. Bit 7: Phase # = (phaseStatusGroupNumber * 8) Bit 6: Phase # = (phaseStatusGroupNumber * 8) - 1 Bit 5: Phase # = (phaseStatusGroupNumber * 8) - 2 Bit 4: Phase # = (phaseStatusGroupNumber * 8) - 3 Bit 3: Phase # = (phaseStatusGroupNumber * 8) - 4 Bit 2: Phase # = (phaseStatusGroupNumber * 8) - 5 Bit 1: Phase # = (phaseStatusGroupNumber * 8) - 6 Bit 0: Phase # = (phaseStatusGroupNumber * 8) - 7 1.3.6.1.4.1.1206.4.2.1.1.4.1.2 S" ::= { phaseStatusGroupEntry 2 } phaseStatusGroupYellows OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " Phase Yellow Output Status Mask, when a bit = 1, the Phase Yellow is currently active. When a bit = 0, the Phase Yellow is NOT currently active. Bit 7: Phase # = (phaseStatusGroupNumber * 8) Bit 6: Phase # = (phaseStatusGroupNumber * 8) - 1 Bit 5: Phase # = (phaseStatusGroupNumber * 8) - 2 Bit 4: Phase # = (phaseStatusGroupNumber * 8) - 3 Bit 3: Phase # = (phaseStatusGroupNumber * 8) - 4 Bit 2: Phase # = (phaseStatusGroupNumber * 8) - 5 Bit 1: Phase # = (phaseStatusGroupNumber * 8) - 6 Bit 0: Phase # = (phaseStatusGroupNumber * 8) - 7 1.3.6.1.4.1.1206.4.2.1.1.4.1.3 S" ::= { phaseStatusGroupEntry 3 } phaseStatusGroupGreens OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " Phase Green Output Status Mask, when a bit = 1, the Phase Green is currently active. When a bit = 0, the Phase Green is NOT currently active. Bit 7: Phase # = (phaseStatusGroupNumber * 8) Bit 6: Phase # = (phaseStatusGroupNumber * 8) - 1 Bit 5: Phase # = (phaseStatusGroupNumber * 8) - 2 Bit 4: Phase # = (phaseStatusGroupNumber * 8) - 3 Bit 3: Phase # = (phaseStatusGroupNumber * 8) - 4 Bit 2: Phase # = (phaseStatusGroupNumber * 8) - 5 Bit 1: Phase # = (phaseStatusGroupNumber * 8) - 6 Bit 0: Phase # = (phaseStatusGroupNumber * 8) - 7 1.3.6.1.4.1.1206.4.2.1.1.4.1.4 S" ::= { phaseStatusGroupEntry 4 } phaseStatusGroupDontWalks OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " Phase Dont Walk Output Status Mask, when a bit = 1, the Phase Dont Walk is currently active. When a bit = 0, the Phase Dont Walk is NOT currently active. Bit 7: Phase # = (phaseStatusGroupNumber * 8) Bit 6: Phase # = (phaseStatusGroupNumber * 8) - 1 Bit 5: Phase # = (phaseStatusGroupNumber * 8) - 2 Bit 4: Phase # = (phaseStatusGroupNumber * 8) - 3 Bit 3: Phase # = (phaseStatusGroupNumber * 8) - 4 Bit 2: Phase # = (phaseStatusGroupNumber * 8) - 5 Bit 1: Phase # = (phaseStatusGroupNumber * 8) - 6 Bit 0: Phase # = (phaseStatusGroupNumber * 8) - 7 1.3.6.1.4.1.1206.4.2.1.1.4.1.5 S" ::= { phaseStatusGroupEntry 5 } phaseStatusGroupPedClears OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " Phase Ped Clear Output Status Mask, when a bit = 1, the Phase Ped Clear is currently active. When a bit = 0, the Phase Ped Clear is NOT currently active. Bit 7: Phase # = (phaseStatusGroupNumber * 8) Bit 6: Phase # = (phaseStatusGroupNumber * 8) - 1 Bit 5: Phase # = (phaseStatusGroupNumber * 8) - 2 Bit 4: Phase # = (phaseStatusGroupNumber * 8) - 3 Bit 3: Phase # = (phaseStatusGroupNumber * 8) - 4 Bit 2: Phase # = (phaseStatusGroupNumber * 8) - 5 Bit 1: Phase # = (phaseStatusGroupNumber * 8) - 6 Bit 0: Phase # = (phaseStatusGroupNumber * 8) - 7 1.3.6.1.4.1.1206.4.2.1.1.4.1.6 S" ::= { phaseStatusGroupEntry 6 } phaseStatusGroupWalks OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " Phase Walk Output Status Mask, when a bit = 1, the Phase Walk is currently active. When a bit = 0, the Phase Walk is NOT currently active. Bit 7: Phase # = (phaseStatusGroupNumber * 8) Bit 6: Phase # = (phaseStatusGroupNumber * 8) - 1 Bit 5: Phase # = (phaseStatusGroupNumber * 8) - 2 Bit 4: Phase # = (phaseStatusGroupNumber * 8) - 3 Bit 3: Phase # = (phaseStatusGroupNumber * 8) - 4 Bit 2: Phase # = (phaseStatusGroupNumber * 8) - 5 Bit 1: Phase # = (phaseStatusGroupNumber * 8) - 6 Bit 0: Phase # = (phaseStatusGroupNumber * 8) - 7 1.3.6.1.4.1.1206.4.2.1.1.4.1.7 S" ::= { phaseStatusGroupEntry 7 } phaseStatusGroupVehCalls OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " Phase Vehicle Call Status Mask, when a bit = 1, the Phase vehicle currently has a call for service. When a bit = 0, the Phase vehicle currently does NOT have a call for service. Bit 7: Phase # = (phaseStatusGroupNumber * 8) Bit 6: Phase # = (phaseStatusGroupNumber * 8) - 1 Bit 5: Phase # = (phaseStatusGroupNumber * 8) - 2 Bit 4: Phase # = (phaseStatusGroupNumber * 8) - 3 Bit 3: Phase # = (phaseStatusGroupNumber * 8) - 4 Bit 2: Phase # = (phaseStatusGroupNumber * 8) - 5 Bit 1: Phase # = (phaseStatusGroupNumber * 8) - 6 Bit 0: Phase # = (phaseStatusGroupNumber * 8) - 7 1.3.6.1.4.1.1206.4.2.1.1.4.1.8 S" ::= { phaseStatusGroupEntry 8 } phaseStatusGroupPedCalls OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " Phase Pedestrian Call Status Mask, when a bit = 1, the Phase pedestrian currently has a call for service. When a bit = 0, the Phase pedestrian currently does NOT have a call for service. Bit 7: Phase # = (phaseStatusGroupNumber * 8) Bit 6: Phase # = (phaseStatusGroupNumber * 8) - 1 Bit 5: Phase # = (phaseStatusGroupNumber * 8) - 2 Bit 4: Phase # = (phaseStatusGroupNumber * 8) - 3 Bit 3: Phase # = (phaseStatusGroupNumber * 8) - 4 Bit 2: Phase # = (phaseStatusGroupNumber * 8) - 5 Bit 1: Phase # = (phaseStatusGroupNumber * 8) - 6 Bit 0: Phase # = (phaseStatusGroupNumber * 8) - 7 1.3.6.1.4.1.1206.4.2.1.1.4.1.9 S" ::= { phaseStatusGroupEntry 9 } phaseStatusGroupPhaseOns OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " Phase On Status Mask, when a bit = 1, the Phase is currently active. When a bit = 0, the Phase currently is NOT active. The phase is ON during the Green, Yellow, & Red Clearance intervals of that phase. It shall be permissible for this STATUS to be True (bit=1) during the Red Dwell state. Bit 7: Phase # = (phaseStatusGroupNumber * 8) Bit 6: Phase # = (phaseStatusGroupNumber * 8) - 1 Bit 5: Phase # = (phaseStatusGroupNumber * 8) - 2 Bit 4: Phase # = (phaseStatusGroupNumber * 8) - 3 Bit 3: Phase # = (phaseStatusGroupNumber * 8) - 4 Bit 2: Phase # = (phaseStatusGroupNumber * 8) - 5 Bit 1: Phase # = (phaseStatusGroupNumber * 8) - 6 Bit 0: Phase # = (phaseStatusGroupNumber * 8) - 7 1.3.6.1.4.1.1206.4.2.1.1.4.1.10 S" ::= { phaseStatusGroupEntry 10 } phaseStatusGroupPhaseNexts OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " Phase Next Status Mask, when a bit = 1, the Phase currently is committed to be NEXT in sequence & remains present until the phase becomes active (On/Timing). When a bit = 0, the Phase currently is NOT committed to be NEXT in sequence. The phase next to be serviced shall be determined at the end of the green interval of the terminating phase; except that if the decision cannot be made at the end of the Green interval, it shall not be made until after the end of all Vehicle Change & Clearance intervals. Bit 7: Phase # = (phaseStatusGroupNumber * 8) Bit 6: Phase # = (phaseStatusGroupNumber * 8) - 1 Bit 5: Phase # = (phaseStatusGroupNumber * 8) - 2 Bit 4: Phase # = (phaseStatusGroupNumber * 8) - 3 Bit 3: Phase # = (phaseStatusGroupNumber * 8) - 4 Bit 2: Phase # = (phaseStatusGroupNumber * 8) - 5 Bit 1: Phase # = (phaseStatusGroupNumber * 8) - 6 Bit 0: Phase # = (phaseStatusGroupNumber * 8) - 7 1.3.6.1.4.1.1206.4.2.1.1.4.1.11 S" ::= { phaseStatusGroupEntry 11 } phaseControlGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF PhaseControlGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table containing Controller Unit Phase Control in groups of eight phases. The number of rows in this table is equal to the maxPhaseGroups object. static 1.3.6.1.4.1.1206.4.2.1.1.5 group" ::= { phase 5 } phaseControlGroupEntry OBJECT-TYPE SYNTAX PhaseControlGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Phase Control for eight Controller Unit phases. 1.3.6.1.4.1.1206.4.2.1.1.5.1" INDEX { phaseControlGroupNumber } ::= { phaseControlGroupTable 1 } PhaseControlGroupEntry ::= SEQUENCE { phaseControlGroupNumber INTEGER, phaseControlGroupPhaseOmit INTEGER, phaseControlGroupPedOmit INTEGER, phaseControlGroupHold INTEGER, phaseControlGroupForceOff INTEGER, phaseControlGroupVehCall INTEGER, phaseControlGroupPedCall INTEGER } phaseControlGroupNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The Phase Control Group number for objects in this row. This value shall not exceed the maxPhaseGroups object value. 1.3.6.1.4.1.1206.4.2.1.1.5.1.1 S group" ::= { phaseControlGroupEntry 1 } phaseControlGroupPhaseOmit OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " This object is used to allow a remote entity to omit phases from being serviced in the device. When a bit = 1, the device shall activate the System Phase Omit control for that phase. When a bit = 0, the device shall not activate the System Phase Omit control for that phase. Bit 7: Phase # = (phaseControlGroupNumber * 8) Bit 6: Phase # = (phaseControlGroupNumber * 8) - 1 Bit 5: Phase # = (phaseControlGroupNumber * 8) - 2 Bit 4: Phase # = (phaseControlGroupNumber * 8) - 3 Bit 3: Phase # = (phaseControlGroupNumber * 8) - 4 Bit 2: Phase # = (phaseControlGroupNumber * 8) - 5 Bit 1: Phase # = (phaseControlGroupNumber * 8) - 6 Bit 0: Phase # = (phaseControlGroupNumber * 8) - 7 The device shall reset this object to ZERO when in BACKUP Mode. A write to this object shall reset the Backup timer to ZERO (see unitBackupTime). 1.3.6.1.4.1.1206.4.2.1.1.5.1.2 C" REFERENCE "NEMA TS 2 Clause 3.5.3.11.2" ::= { phaseControlGroupEntry 2 } phaseControlGroupPedOmit OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " This object is used to allow a remote entity to omit peds from being serviced in the device. When a bit = 1, the device shall activate the System Ped Omit control for that phase. When a bit = 0, the device shall not activate the System Ped Omit control for that phase. Bit 7: Phase # = (phaseControlGroupNumber * 8) Bit 6: Phase # = (phaseControlGroupNumber * 8) - 1 Bit 5: Phase # = (phaseControlGroupNumber * 8) - 2 Bit 4: Phase # = (phaseControlGroupNumber * 8) - 3 Bit 3: Phase # = (phaseControlGroupNumber * 8) - 4 Bit 2: Phase # = (phaseControlGroupNumber * 8) - 5 Bit 1: Phase # = (phaseControlGroupNumber * 8) - 6 Bit 0: Phase # = (phaseControlGroupNumber * 8) - 7 The device shall reset this object to ZERO when in BACKUP Mode. A write to this object shall reset the Backup timer to ZERO (see unitBackupTime). 1.3.6.1.4.1.1206.4.2.1.1.5.1.3 C" REFERENCE "NEMA TS 2 Clause 3.5.3.11.3" ::= { phaseControlGroupEntry 3 } phaseControlGroupHold OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " This object is used to allow a remote entity to hold phases in the device. When a bit = 1, the device shall activate the System Phase Hold control for that phase. When a bit = 0, the device shall not activate the System Phase Hold control for that phase. Bit 7: Phase # = (phaseControlGroupNumber * 8) Bit 6: Phase # = (phaseControlGroupNumber * 8) - 1 Bit 5: Phase # = (phaseControlGroupNumber * 8) - 2 Bit 4: Phase # = (phaseControlGroupNumber * 8) - 3 Bit 3: Phase # = (phaseControlGroupNumber * 8) - 4 Bit 2: Phase # = (phaseControlGroupNumber * 8) - 5 Bit 1: Phase # = (phaseControlGroupNumber * 8) - 6 Bit 0: Phase # = (phaseControlGroupNumber * 8) - 7 The device shall reset this object to ZERO when in BACKUP Mode. A write to this object shall reset the Backup timer to ZERO (see unitBackupTime). 1.3.6.1.4.1.1206.4.2.1.1.5.1.4 C" REFERENCE "NEMA TS 2 Clause 3.5.3.11.1" ::= { phaseControlGroupEntry 4 } phaseControlGroupForceOff OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " This object is used to apply force offs on a per phase basis. When a bit = 1, the device shall activate the System Phase Force Off control for that phase. When a bit = 0, the device shall not activate the System Phase Force Off control for that phase. When the phase green terminates, the associated bit shall be reset to 0. Bit 7: Phase # = (phaseControlGroupNumber * 8) Bit 6: Phase # = (phaseControlGroupNumber * 8) - 1 Bit 5: Phase # = (phaseControlGroupNumber * 8) - 2 Bit 4: Phase # = (phaseControlGroupNumber * 8) - 3 Bit 3: Phase # = (phaseControlGroupNumber * 8) - 4 Bit 2: Phase # = (phaseControlGroupNumber * 8) - 5 Bit 1: Phase # = (phaseControlGroupNumber * 8) - 6 Bit 0: Phase # = (phaseControlGroupNumber * 8) - 7 The device shall reset this object to ZERO when in BACKUP Mode. A write to this object shall reset the Backup timer to ZERO (see unitBackupTime). 1.3.6.1.4.1.1206.4.2.1.1.5.1.5 C" ::= { phaseControlGroupEntry 5 } phaseControlGroupVehCall OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " This object is used to allow a remote entity to place calls for vehicle service in the device. When a bit = 1, the device shall place a call for vehicle service on that phase. When a bit = 0, the device shall not place a call for vehicle service on that phase. Bit 7: Phase # = (phaseControlGroupNumber * 8) Bit 6: Phase # = (phaseControlGroupNumber * 8) - 1 Bit 5: Phase # = (phaseControlGroupNumber * 8) - 2 Bit 4: Phase # = (phaseControlGroupNumber * 8) - 3 Bit 3: Phase # = (phaseControlGroupNumber * 8) - 4 Bit 2: Phase # = (phaseControlGroupNumber * 8) - 5 Bit 1: Phase # = (phaseControlGroupNumber * 8) - 6 Bit 0: Phase # = (phaseControlGroupNumber * 8) - 7 The device shall reset this object to ZERO when in BACKUP Mode. A write to this object shall reset the Backup timer to ZERO (see unitBackupTime). 1.3.6.1.4.1.1206.4.2.1.1.5.1.6 C" ::= { phaseControlGroupEntry 6 } phaseControlGroupPedCall OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " This object is used to allow a remote entity to place calls for ped service in the device. When a bit = 1, the device shall place a call for ped service on that phase. When a bit = 0, the device shall not place a call for ped service on that phase. Bit 7: Phase # = (phaseControlGroupNumber * 8) Bit 6: Phase # = (phaseControlGroupNumber * 8) - 1 Bit 5: Phase # = (phaseControlGroupNumber * 8) - 2 Bit 4: Phase # = (phaseControlGroupNumber * 8) - 3 Bit 3: Phase # = (phaseControlGroupNumber * 8) - 4 Bit 2: Phase # = (phaseControlGroupNumber * 8) - 5 Bit 1: Phase # = (phaseControlGroupNumber * 8) - 6 Bit 0: Phase # = (phaseControlGroupNumber * 8) - 7 The device shall reset this object to ZERO when in BACKUP Mode. A write to this object shall reset the Backup timer to ZERO (see unitBackupTime). 1.3.6.1.4.1.1206.4.2.1.1.5.1.7 C" ::= { phaseControlGroupEntry 7 } detector OBJECT IDENTIFIER ::= { asc 2 } -- This defines a node for supporting detector objects. maxVehicleDetectors OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The Maximum Number of Vehicle Detectors this Controller Unit supports. This object indicates the maximum rows which shall appear in the vehicleDetectorTable object. 1.3.6.1.4.1.1206.4.2.1.2.1 S detector" ::= { detector 1 } vehicleDetectorTable OBJECT-TYPE SYNTAX SEQUENCE OF VehicleDetectorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table containing Controller Unit vehicle detector parameters. The number of rows in this table is equal to the maxVehicleDetectors object. static 1.3.6.1.4.1.1206.4.2.1.2.2" ::= { detector 2 } vehicleDetectorEntry OBJECT-TYPE SYNTAX VehicleDetectorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Parameters for a specific Controller Unit detector. 1.3.6.1.4.1.1206.4.2.1.2.2.1" INDEX { vehicleDetectorNumber } ::= { vehicleDetectorTable 1 } VehicleDetectorEntry ::= SEQUENCE { vehicleDetectorNumber INTEGER, vehicleDetectorOptions INTEGER, vehicleDetectorCallPhase INTEGER, vehicleDetectorSwitchPhase INTEGER, vehicleDetectorDelay INTEGER, vehicleDetectorExtend INTEGER, vehicleDetectorQueueLimit INTEGER, vehicleDetectorNoActivity INTEGER, vehicleDetectorMaxPresence INTEGER, vehicleDetectorErraticCounts INTEGER, vehicleDetectorFailTime INTEGER, vehicleDetectorAlarms INTEGER, vehicleDetectorReportedAlarms INTEGER, vehicleDetectorReset INTEGER, vehicleDetectorOptions2 INTEGER, vehicleDetectorPairedDetector INTEGER, vehicleDetectorPairedDetectorSpacing INTEGER, vehicleDetectorAvgVehicleLength INTEGER, vehicleDetectorLength INTEGER, vehicleDetectorTravelMode INTEGER } vehicleDetectorNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The vehicle detector number for objects in this row. The value shall not exceed the maxVehicleDetectors object value. 1.3.6.1.4.1.1206.4.2.1.2.2.1.1 S detector" ::= { vehicleDetectorEntry 1 } vehicleDetectorOptions OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Vehicle Detector Options Parameter as follows (0=Disabled, 1=Enabled): Bit 7: Call - if Enabled, the CU shall place a demand for vehicular service on the assigned phase when the phase is not timing the green interval and an actuation is present. Bit 6: Queue - if Enabled, the CU shall extend the green interval of the assigned phase until a gap occurs (no actuation) or until the green has been active longer than the vehicleDetectorQueueLimit time. This is optional. Bit 5: AddedInitial - if Enabled, the CU shall accumulate detector actuation counts for use in the added initial calculations. Counts shall be accumulated from the beginning of the yellow interval to the beginning of the green interval. Bit 4: Passage - if Enabled, the CU shall maintain a reset to the associated phase passage timer for the duration of the detector actuation when the phase is green. Bit 3: Red Lock Call - if Enabled, the detector will lock a call to the assigned phase if an actuation occurs while the phase is not timing Green or Yellow. This mode is optional. Bit 2: Yellow Lock Call - if Enabled, the detector will lock a call to the assigned phase if an actuation occurs while the phase is not timing Green. Bit 1: Occupancy Detector - if Enabled, the detector collects data for the associated detector occupancy object(s). This capability may not be supported on all detector inputs to a device. Bit 0: Volume Detector - if Enabled, the detector collects data for the associated detector volume object(s). This capability may not be supported on all detector inputs to a device. A SET of both bits 2 & 3 = 1 shall result in bit 2=1 and bit 3=0. 1.3.6.1.4.1.1206.4.2.1.2.2.1.2 P" ::= { vehicleDetectorEntry 2} -- Note: { vehicleDetectorEntry 3} is not used. vehicleDetectorCallPhase OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " This object contains assigned phase number for the detector input associated with this row. The associated detector call capability is enabled when this object is set to a non-zero value. The value shall not exceed the value of maxPhases. 1.3.6.1.4.1.1206.4.2.1.2.2.1.4 P phase" REFERENCE "NEMA TS 2 Clause 3.5.5.5.4 and 3.5.5.5.5" ::= { vehicleDetectorEntry 4 } vehicleDetectorSwitchPhase OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Detector Switch Phase Parameter (i.e., Phase Number). The phase to which a vehicle detector actuation shall be switched when the assigned phase is Yellow or Red and the Switch Phase is Green. 1.3.6.1.4.1.1206.4.2.1.2.2.1.5 P phase" REFERENCE "NEMA TS 2 Clause 3.5.5.5.4.c" ::= { vehicleDetectorEntry 5 } vehicleDetectorDelay OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION " Detector Delay Parameter in tenth seconds (0- 255.0 sec). The period a detector actuation (input recognition) shall be delayed when the phase is not Green. If a management station attempts to set a value between 2551 and 65535, inclusive, the parameter is undefined. 1.3.6.1.4.1.1206.4.2.1.2.2.1.6 P tenth second" REFERENCE "NEMA TS 2 Clause 3.5.5.5.4.a" ::= { vehicleDetectorEntry 6 } vehicleDetectorExtend OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Detector Extend Parameter in tenth seconds (0-25.5 sec). The period a vehicle detector actuation (input duration) shall be extended from the point of termination, when the phase is Green. 1.3.6.1.4.1.1206.4.2.1.2.2.1.7 P tenth second" REFERENCE "NEMA TS 2 Clause 3.5.5.5.4.b" ::= { vehicleDetectorEntry 7 } vehicleDetectorQueueLimit OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Detector Queue Limit parameter in seconds (0-255 sec). The length of time that an actuation from a queue detector may continue into the phase green. This time begins when the phase becomes green and when it expires any associated detector inputs shall be ignored. This time may be shorter due to other overriding device parameters (i.e. Maximum time, Force Offs, ...). 1.3.6.1.4.1.1206.4.2.1.2.2.1.8 P second" ::= { vehicleDetectorEntry 8 } vehicleDetectorNoActivity OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Detector No Activity diagnostic Parameter in minutes (0-255 min.). If an active detector does not exhibit an actuation in the specified period, it is considered a fault by the diagnostics and the detector is classified as Failed. A value of 0 for this object shall disable this diagnostic for this detector. 1.3.6.1.4.1.1206.4.2.1.2.2.1.9 P minute" REFERENCE "NEMA TS 2 Clause 3.9.3.1.4.1" ::= { vehicleDetectorEntry 9 } vehicleDetectorMaxPresence OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Detector Maximum Presence diagnostic Parameter in minutes (0-255 min.). If an active detector exhibits continuous detection for too long a period, it is considered a fault by the diagnostics and the detector is classified as Failed. A value of 0 for this object shall disable this diagnostic for this detector. 1.3.6.1.4.1.1206.4.2.1.2.2.1.10 P minute" REFERENCE "NEMA TS 2 Clause 3.9.3.1.4.2" ::= { vehicleDetectorEntry 10 } vehicleDetectorErraticCounts OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Detector Erratic Counts diagnostic Parameter in counts/minute (0-255 cpm). If an active detector exhibits excessive actuations, it is considered a fault by the diagnostics and the detector is classified as Failed. A value of 0 for this object shall disable this diagnostic for this detector. 1.3.6.1.4.1.1206.4.2.1.2.2.1.11 P count" REFERENCE "NEMA TS 2 Clause 3.9.3.1.4.3" ::= { vehicleDetectorEntry 11 } vehicleDetectorFailTime OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Detector Fail Time in seconds (0..255 sec). If a detector diagnostic indicates that the associated detector input is failed, then a call shall be placed on the associated phase during all non-green intervals. When each green interval begins the call shall be maintained for the length of time specified by this object and then removed. If the value of this object equals the maximum value (255) then a constant call shall be placed on the associated phase (max recall). If the value of this object equals zero then no call shall be placed on the associated phase for any interval (no recall). Compliant devices may support a limited capability for this object (i.e. only max recall or max recall and no recall). At a minimum the max recall setting must be supported. 1.3.6.1.4.1.1206.4.2.1.2.2.1.12 P second" ::= { vehicleDetectorEntry 12 } vehicleDetectorAlarms OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " This object shall return indications of detector alarms. Detector Alarms are indicated as follows: Bit 7: Other Fault - The detector has failed due to some other cause. Bit 6: Reserved. Bit 5: Reserved. Bit 4: Configuration Fault - Detector is assigned but is not supported. Bit 3: Communications Fault - Communications to the device (if present) have failed. Bit 2: Erratic Output Fault - This detector has been flagged as non-operational due to erratic outputs (excessive counts) by the CU detector diagnostic. Bit 1: Max Presence Fault - This detector has been flagged as non-operational due to a presence indicator that exceeded the maximum expected time by the CU detector diagnostic. Bit 0: No Activity Fault - This detector has been flagged as non- operational due to lower than expected activity by the CU detector diagnostic. Once set a bit shall maintain its state as long as the condition exists. The bit shall clear when the condition no longer exists. 1.3.6.1.4.1.1206.4.2.1.2.2.1.13 S" ::= { vehicleDetectorEntry 13 } vehicleDetectorReportedAlarms OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " This object shall return detector device reported alarms (via some communications mechanism). Inductive Loop Detector Alarms are indicated as follows: Bit 7: Reserved. Bit 6: Reserved. Bit 5: Reserved. Bit 4: Excessive Change Fault - This detector has been flagged as non-operational due to an inductance change that exceeded expected values. Bit 3: Shorted Loop Fault - This detector has been flagged as non-operational due to a shorted loop wire. Bit 2: Open Loop Fault - This detector has been flagged as non- operational due to an open loop (broken wire). Bit 1: Watchdog Fault - This detector has been flagged as non- operational due to a watchdog error. Bit 0: Other - This detector has been flagged as non-operational due to some other error. Once set a bit shall maintain its state as long as the condition exists. The bit shall clear when the condition no longer exists. 1.3.6.1.4.1.1206.4.2.1.2.2.1.14 S" ::= { vehicleDetectorEntry 14 } vehicleDetectorReset OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-write STATUS mandatory DESCRIPTION " This object when set to TRUE (one) shall cause the CU to command the associated detector to reset. This object shall automatically return to FALSE (zero) after the CU has issued the reset command. Note: this may affect other detector (detector channels) that are physically attached to a common reset line. 1.3.6.1.4.1.1206.4.2.1.2.2.1.15 C" ::= { vehicleDetectorEntry 15 } vehicleDetectorOptions2 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " A bit-mapped value as defined below for configuring detector options. bits 7-3 Reserved. bit 2 0=CUSTOM, 1=NTCIP Default Detector Speed Mode Option. For a vehicle detector operating in pairs, this option is used when there is an error on one of the paired detectors. It identifies how the controller should calculate speed without the other detector. CUSTOM indicates a manufacturer specific calculation. NTCIP indicates the use of the calculation Speed = (Average Vehicle Length + Detector Length) / Detect Time. bit 1 0=TRAIL, 1=LEAD Detector Placement Option. For a vehicle detector operating in pairs, this option indicates the leading and trailing detectors. LEAD indicates that the detector is the leading detector of the pair. TRAIL indicates that the detector is a trailing detector in the pair. bit 0 0=DISABLED, 1=ENABLED Speed Detector. If enabled, the detector is used to collect speed data (See volumeOccupancyTable and detectorAvgSpeed). This capability may not be supported on all detector inputs to a device. 1.3.6.1.4.1.1206.4.2.1.2.2.1.16 P" ::= { vehicleDetectorEntry 16 } vehicleDetectorPairedDetector OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " This is a detector identifier (vehicleDetectorNumber) that is used to determine speed. A value of 0 indicates there is no paired detector. Setting this value will automatically add this detector as the given detector's vehicleDetectorPairedDetector. 1.3.6.1.4.1.1206.4.2.1.2.2.1.17 P" DEFVAL { 0 } ::= { vehicleDetectorEntry 17 } vehicleDetectorPairedDetectorSpacing OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION " This parameter allows the user to set the spacing, in 0.01 meters, between paired detectors for use in calculating vehicle speeds. This parameter is measured from the leading edge of one detector to the leading edge of the paired detector. A value of 0 indicates there is no paired detector. 1.3.6.1.4.1.1206.4.2.1.2.2.1.18 P one-hundredth of a meter" DEFVAL { 0 } ::= { vehicleDetectorEntry 18 } vehicleDetectorAvgVehicleLength OBJECT-TYPE SYNTAX INTEGER (1..4000) ACCESS read-write STATUS mandatory DESCRIPTION " This parameter allows the user to set the average vehicle length for use in determining speed and classification. This allows for a range of lengths between 0.01 meters to 40 meters in length. 1.3.6.1.4.1.1206.4.2.1.2.2.1.19 P one-hundredth of a meter" ::= { vehicleDetectorEntry 19 } vehicleDetectorLength OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION " This parameter allows the user to set the length of the detection zone. In the case of a loop detector, this is the length of the loop. Values 01 to 4000 are used to represent the length. This allows for a range of lengths between 0.01 meters to 40 meters in length. The value of 65535 shall be returned to represent no length set. Values 4001 to 65534 are not used. 1.3.6.1.4.1.1206.4.2.1.2.2.1.20 P one-hundredth of a meter" DEFVAL { 65535 } ::= { vehicleDetectorEntry 20 } vehicleDetectorTravelMode OBJECT-TYPE SYNTAX INTEGER { other (1), vehicle (2), transit (3), bicycle (4) } ACCESS read-write STATUS mandatory DESCRIPTION " This parameter allows the user to identify detectors for specific types of travel modes. other: refers to a detector for a travel type not defined in this standard vehicle: refers to a detector identified for vehicles. transit: refers to a detector identified for transit vehicles. bicycle: refers to a detector identified for bicycles. 1.3.6.1.4.1.1206.4.2.1.2.2.1.21 P" DEFVAL { vehicle } ::= { vehicleDetectorEntry 21 } maxVehicleDetectorStatusGroups OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The maximum number of detector status groups (8 detectors per group) this device supports. This value is equal to TRUNCATE [(maxVehicleDetectors + 7 ) / 8]. This object indicates the maximum number of rows which shall appear in the vehicleDetectorStatusGroupTable object. 1.3.6.1.4.1.1206.4.2.1.2.3 S group" ::= { detector 3 } vehicleDetectorStatusGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF VehicleDetectorStatusGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table containing detector status in groups of eight detectors. The number of rows in this table is equal to the maxVehicleDetectorStatusGroups object. static 1.3.6.1.4.1.1206.4.2.1.2.4" ::= { detector 4 } vehicleDetectorStatusGroupEntry OBJECT-TYPE SYNTAX VehicleDetectorStatusGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A group (row) of detector status. 1.3.6.1.4.1.1206.4.2.1.2.4.1" INDEX { vehicleDetectorStatusGroupNumber } ::= { vehicleDetectorStatusGroupTable 1 } VehicleDetectorStatusGroupEntry ::= SEQUENCE { vehicleDetectorStatusGroupNumber INTEGER, vehicleDetectorStatusGroupActive INTEGER, vehicleDetectorStatusGroupAlarms INTEGER } vehicleDetectorStatusGroupNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The detector status group number for objects in this row. This value shall not exceed the maxVehicleDetectorStatusGroups object value. 1.3.6.1.4.1.1206.4.2.1.2.4.1.1 S group" ::= { vehicleDetectorStatusGroupEntry 1 } vehicleDetectorStatusGroupActive OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " This object shall return the detection STATUS of each detector associated with the group. Each detector shall be represented as ON (detect) or OFF (no-detect) by individual bits in this object. If a detector is ON then the associated bit shall be set (1). If a detector is OFF then the associated bit shall be clear (0). Bit 7: Det # = ( vehicleDetectorStatusGroupNumber * 8) Bit 6: Det # = ( vehicleDetectorStatusGroupNumber * 8) - 1 Bit 5: Det # = ( vehicleDetectorStatusGroupNumber * 8) - 2 Bit 4: Det # = ( vehicleDetectorStatusGroupNumber * 8) - 3 Bit 3: Det # = ( vehicleDetectorStatusGroupNumber * 8) - 4 Bit 2: Det # = ( vehicleDetectorStatusGroupNumber * 8) - 5 Bit 1: Det # = ( vehicleDetectorStatusGroupNumber * 8) - 6 Bit 0: Det # = ( vehicleDetectorStatusGroupNumber * 8) - 7 1.3.6.1.4.1.1206.4.2.1.2.4.1.2 S" ::= { vehicleDetectorStatusGroupEntry 2 } vehicleDetectorStatusGroupAlarms OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " This object shall return the alarm status of the detectors associated with the group. Each detector alarm status shall be represented as ON or OFF by individual bits in this object. If any detector alarm (defined in the vehicleDetectorAlarm object) is active the associated bit shall be set (1). If a detector alarm is not active the associated bit shall be clear (0). Bit 7: Det # = ( vehicleDetectorStatusGroupNumber * 8) Bit 6: Det # = ( vehicleDetectorStatusGroupNumber * 8) - 1 Bit 5: Det # = ( vehicleDetectorStatusGroupNumber * 8) - 2 Bit 4: Det # = ( vehicleDetectorStatusGroupNumber * 8) - 3 Bit 3: Det # = ( vehicleDetectorStatusGroupNumber * 8) - 4 Bit 2: Det # = ( vehicleDetectorStatusGroupNumber * 8) - 5 Bit 1: Det # = ( vehicleDetectorStatusGroupNumber * 8) - 6 Bit 0: Det # = ( vehicleDetectorStatusGroupNumber * 8) - 7 1.3.6.1.4.1.1206.4.2.1.2.4.1.3 S" ::= { vehicleDetectorStatusGroupEntry 3 } volumeOccupancyReport OBJECT IDENTIFIER ::= { detector 5 } -- This node contains the objects necessary to support volume / -- occupancy reporting. volumeOccupancySequence OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " This object defines a Sequence Number for Volume/Occupancy data collection. This object is used to detect duplicate or missing reports. The value cycles within the limits of 0 to 255. This object is incremented by one at the expiration of the volumeOccupancyPeriod time. 1.3.6.1.4.1.1206.4.2.1.2.5.1 S sequence" ::= { volumeOccupancyReport 1 } volumeOccupancyPeriod OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " This object defines the number of seconds (0- 255 sec) that comprise the Volume/Occupancy/Speed collection period. When the collection period expires the device shall increment the volumeOccupancySequence, update the volumeOccupancyTable entries and reset the volume occupancy timer. If the value is 0, the value in volumeOccupancyPeriodV3 is used if supported. If both the volumeOccupancyPeriod and volumeOccupancyPeriodV3 are 0, then no sampling is to be performed. If both the volumeOccupancyPeriod and volumeOccupancyPeriodV3 are non-zero then the volumeOccupancyPeriod takes precedence. 1.3.6.1.4.1.1206.4.2.1.2.5.2 P second" ::= { volumeOccupancyReport 2 } activeVolumeOccupancyDetectors OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " The number of detectors in this device. This object indicates how many rows are in the volumeOccupancyTable object. There shall be a row for every detector that is collecting volume, occupancy, or speed data (refer to detectorOptions in the detectorTable). 1.3.6.1.4.1.1206.4.2.1.2.5.3 S detector" ::= { volumeOccupancyReport 3 } volumeOccupancyTable OBJECT-TYPE SYNTAX SEQUENCE OF VolumeOccupancyEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table containing Detector Volume, Occupancy and Speed data collected. The number of rows in this table is equal to the activeVolumeOccupancyDetectors object. static 1.3.6.1.4.1.1206.4.2.1.2.5.4" ::= { volumeOccupancyReport 4 } volumeOccupancyEntry OBJECT-TYPE SYNTAX VolumeOccupancyEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " The Volume, Occupancy and Speed data collected for one of the detectors in the device. 1.3.6.1.4.1.1206.4.2.1.2.5.4.1" INDEX { vehicleDetectorNumber } ::= { volumeOccupancyTable 1 } VolumeOccupancyEntry ::= SEQUENCE { detectorVolume INTEGER, detectorOccupancy INTEGER, detectorAvgSpeed INTEGER } detectorVolume OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " Detector Volume data collected over the volumeOccupancyPeriod. This value shall range from 0 to 254 indicating the volume of traffic crossing the associated detectorNumber during the collection period. The value 255 shall indicate volume overflow. 1.3.6.1.4.1.1206.4.2.1.2.5.4.1.1 S volume" ::= { volumeOccupancyEntry 1 } detectorOccupancy OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " Detector Occupancy as a percentage of the volumeOccupancyPeriod over which the data was collected or Detector Unit Diagnostic Information. The value of the object shall indicate occupancy or detector diagnostic information as follows: Range Meaning 0-200 Detector Occupancy in 0.5% Increments 201-209 Reserved 210 Max Presence Fault 211 No Activity Fault 212 Open loop Fault 213 Shorted loop Fault 214 Excessive Change Fault 215 Reserved 216 Watchdog Fault 217 Erratic Output Fault 218-255 Reserved Faults shall be indicated for all collection periods during which a fault is detected if either occupancy data or volume data is being collected. The highest numbered fault shall be presented if more than one fault is active (i.e. indicate OpenLoop rather than NoActivity). 1.3.6.1.4.1.1206.4.2.1.2.5.4.1.2 S occupancy" ::= { volumeOccupancyEntry 2 } detectorAvgSpeed OBJECT-TYPE SYNTAX INTEGER (0..511) ACCESS read-only STATUS mandatory DESCRIPTION " Average vehicle speed during the volumeOccupancyPeriod over which the data was collected. The value of the object shall indicate average vehicle speed as follows: Range Meaning 0-508 Average vehicle speed in 0.5 kilometers per hour 509 Reserved 510 Average vehicle speed is 255 kilometers per hour or higher 511 Invalid or missing value 1.3.6.1.4.1.1206.4.2.1.2.5.4.1.3 S 0.5 kilometers/hour" DEFVAL { 511 } ::= { volumeOccupancyEntry 3 } volumeOccupancyPeriodV3 OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION " This object indicates the number of seconds (0-3600 seconds) that comprise the Volume/Occupancy/Speed collection period. When the collection period expires the device shall increment the volumeOccupancySequence, update the volumeOccupancyTable entries and reset the volume occupancy timer. If the value is 0, the value in volumeOccupancyPeriod is used if indicated (has a valid non-zero value). If both the volumeOccupancyPeriod and volumeOccupancyPeriodV3 are 0, then no sampling is to be performed. If both the volumeOccupancyPeriod and volumeOccupancyPeriodV3 are non-zero then the volumeOccupancyPeriod takes precedence. A value of 65535 indicates that the sample period equal to current cycle length recorded at local zero. If the sample period is configured to use the cycle length but the ASC is running in Free mode, then no data collection is performed. Value Indication 0 Value of volumeOccupancyPeriod is used if indicated 1-3600 Volume/Occupancy/Speed period in seconds 3601-65534 Reserved 65535 Sample period is same as cycle period recorded at local zero. 1.3.6.1.4.1.1206.4.2.1.2.5.5 P second" ::= { volumeOccupancyReport 5 } detectorSampleTime OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The local time, expressed in seconds since 00:00:00 (midnight) January 1, 1970 of the same time offset, representing the end time of the last completed vehicle detector data collection period. This value changes by 3600 seconds in response to a DST event. 1.3.6.1.4.1.1206.4.2.1.2.5.6 S second" ::= { volumeOccupancyReport 6 } detectorSampleDuration OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION " This object indicates the number of seconds (1-3600 seconds) that comprise the duration of the pedestrian detector data collection period. A value of 0 indicates that duration is invalid. Values of 3601-65535 are reserved. 1.3.6.1.4.1.1206.4.2.1.2.5.7 S second" ::= { volumeOccupancyReport 7 } maxPedestrianDetectors OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The Maximum Number of Pedestrian Detectors this Controller Unit supports. This object indicates the maximum rows which shall appear in the pedestrianDetectorTable object. 1.3.6.1.4.1.1206.4.2.1.2.6 S detector" ::= { detector 6 } pedestrianDetectorTable OBJECT-TYPE SYNTAX SEQUENCE OF PedestrianDetectorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table containing Controller Unit pedestrian detector parameters. The number of rows in this table is equal to the maxPedestrianDetectors object. static 1.3.6.1.4.1.1206.4.2.1.2.7" ::= { detector 7 } pedestrianDetectorEntry OBJECT-TYPE SYNTAX PedestrianDetectorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Parameters for a specific Controller Unit pedestrian detector. 1.3.6.1.4.1.1206.4.2.1.2.7.1" INDEX { pedestrianDetectorNumber } ::= { pedestrianDetectorTable 1 } PedestrianDetectorEntry ::= SEQUENCE { pedestrianDetectorNumber INTEGER, pedestrianDetectorCallPhase INTEGER, pedestrianDetectorNoActivity INTEGER, pedestrianDetectorMaxPresence INTEGER, pedestrianDetectorErraticCounts INTEGER, pedestrianDetectorAlarms INTEGER, pedestrianDetectorReset INTEGER, pedestrianButtonPushTime INTEGER, pedestrianDetectorOptions INTEGER } pedestrianDetectorNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The pedestrianDetector number for objects in this row. The value shall not exceed the maxPedestrianDetectors object value. 1.3.6.1.4.1.1206.4.2.1.2.7.1.1 S detector" ::= { pedestrianDetectorEntry 1 } pedestrianDetectorCallPhase OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " This object contains assigned phase number for the pedestrian detector input associated with this row. The associated detector call capability is enabled when this object is set to a non-zero value. The value shall not exceed the value of maxPhases. 1.3.6.1.4.1.1206.4.2.1.2.7.1.2 P phase" ::= { pedestrianDetectorEntry 2 } pedestrianDetectorNoActivity OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Pedestrian Detector No Activity diagnostic Parameter in minutes (0-255 min.). If an active detector does not exhibit an actuation in the specified period, it is considered a fault by the diagnostics and the detector is classified as Failed. A value of 0 for this object shall disable this diagnostic for this detector. 1.3.6.1.4.1.1206.4.2.1.2.7.1.3 P minute" REFERENCE "NEMA TS 2 Clause 3.9.3.1.4.1" ::= { pedestrianDetectorEntry 3 } pedestrianDetectorMaxPresence OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Pedestrian Detector Maximum Presence diagnostic Parameter in minutes (0-255 min.). If an active detector exhibits continuous detection for too long a period, it is considered a fault by the diagnostics and the detector is classified as Failed. A value of 0 for this object shall disable this diagnostic for this detector. 1.3.6.1.4.1.1206.4.2.1.2.7.1.4 P minute" REFERENCE "NEMA TS 2 Clause 3.9.3.1.4.2" ::= { pedestrianDetectorEntry 4 } pedestrianDetectorErraticCounts OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Pedestrian Detector Erratic Counts diagnostic Parameter in counts/minute (0-255 cpm). If an active detector exhibits excessive actuations, it is considered a fault by the diagnostics and the detector is classified as Failed. A value of 0 for this object shall disable this diagnostic for this detector. 1.3.6.1.4.1.1206.4.2.1.2.7.1.5 P count" REFERENCE "NEMA TS 2 Clause 3.9.3.1.4.3" ::= { pedestrianDetectorEntry 5 } pedestrianDetectorAlarms OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " This object shall return indications of detector alarms. Detector Alarms are indicated as follows (0 = False, 1 = True): Bit 7: Other Fault - The detector has failed due to some other cause. Bit 6: Reserved. Bit 5: Reserved. Bit 4: Configuration Fault - Detector is assigned but is not supported. Bit 3: Communications Fault - Communications to the device (if present) have failed. Bit 2: Erratic Output Fault - This detector has been flagged as non-operational due to erratic outputs (excessive counts) by the CU detector diagnostic. Bit 1: Max Presence Fault - This detector has been flagged as non-operational due to a presence indicator that exceeded the maximum expected time by the CU detector diagnostic. Bit 0: No Activity Fault - This detector has been flagged as non- operational due to lower than expected activity by the CU detector diagnostic Once set a bit shall maintain its state as long as the condition exists. The bit shall clear when the condition no longer exists. 1.3.6.1.4.1.1206.4.2.1.2.7.1.6 S" ::= { pedestrianDetectorEntry 6 } pedestrianDetectorReset OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-write STATUS mandatory DESCRIPTION " This object when set to TRUE (one) shall cause the CU to command the associated detector to reset. This object shall automatically return to FALSE (zero) after the CU has issued the reset command. Note: this may affect other detector (detector channels) that are physically attached to a common reset line. 1.3.6.1.4.1.1206.4.2.1.2.7.1.7 C" DEFVAL { 0 } ::= { pedestrianDetectorEntry 7 } pedestrianButtonPushTime OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " The minimum amount of time, in tenths of a second, a pedestrian call button is pressed to actuate additional accessible features such as increased pedestrian crossing times (phasePedAlternateWalk) or pedestrian clearance times (phasePedAlternateClearance). A value of 0 indicates that all accessible pedestrian signal (APS) features are disabled for the associated detector. 1.3.6.1.4.1.1206.4.2.1.2.7.1.8 tenth of a second" DEFVAL { 0 } ::= { pedestrianDetectorEntry 8 } pedestrianDetectorOptions OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Pedestrian Detector Options Parameter as follows (0=Disabled, 1=Enabled): Bit 7: Reserved. Bit 6: Reserved. Bit 5: Reserved. Bit 4: Reserved. Bit 3: Reserved. Bit 2: Non-locking: If enabled, detector will place a non-locked calls instead of a locked calls. Bit 1: Alternate timing: If enabled, detector will place calls for alternate ped timing instead of normal ped timing. Bit 0: Presence: If enabled, detector indicates presence of pedestrians in the crosswalk instead of placing calls for service. 1.3.6.1.4.1.1206.4.2.1.2.7.1.9 P" DEFVAL { 0 } ::= { pedestrianDetectorEntry 9 } maxPedestrianDetectorGroups OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The maximum number of pedestrian detector status groups (8 detectors per group) this device supports. This value is equal to TRUNCATE [(maxPedestrianDetectors + 7 ) / 8]. This object indicates the maximum number of rows which shall appear in the pedestrianDetectorStatusGroupTable object. 1.3.6.1.4.1.1206.4.2.1.2.8 S group" ::= { detector 8 } pedestrianDetectorStatusGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF PedestrianDetectorStatusGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table containing pedestrian detector status in groups of eight detectors. The number of rows in this table is equal to the maxPedestrianDetectorGroups object. static 1.3.6.1.4.1.1206.4.2.1.2.9" ::= { detector 9 } pedestrianDetectorStatusGroupEntry OBJECT-TYPE SYNTAX PedestrianDetectorStatusGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A group (row) of pedestrian detector status. 1.3.6.1.4.1.1206.4.2.1.2.9.1" INDEX { pedestrianDetectorStatusGroupNumber } ::= { pedestrianDetectorStatusGroupTable 1 } PedestrianDetectorStatusGroupEntry ::= SEQUENCE { pedestrianDetectorStatusGroupNumber INTEGER, pedestrianDetectorStatusGroupActive INTEGER, pedestrianDetectorStatusGroupAlarms INTEGER } pedestrianDetectorStatusGroupNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The pedestrian detector status group number for objects in this row. This value shall not exceed the maxPedestrianDetectorGroups object value. 1.3.6.1.4.1.1206.4.2.1.2.9.1.1 S group" ::= { pedestrianDetectorStatusGroupEntry 1 } pedestrianDetectorStatusGroupActive OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " This object shall return the detection status of each pedestrian detector associated with the group. Each detector shall be represented as ON (detect) or OFF (no-detect) by individual bits in this object. If a detector is ON then the associated bit shall be set (1). If a detector is OFF then the associated bit shall be clear (0). Bit 7: Det # = ( pedestrianDetectorStatusGroupNumber * 8) Bit 6: Det # = ( pedestrianDetectorStatusGroupNumber * 8) - 1 Bit 5: Det # = ( pedestrianDetectorStatusGroupNumber * 8) - 2 Bit 4: Det # = ( pedestrianDetectorStatusGroupNumber * 8) - 3 Bit 3: Det # = ( pedestrianDetectorStatusGroupNumber * 8) - 4 Bit 2: Det # = ( pedestrianDetectorStatusGroupNumber * 8) - 5 Bit 1: Det # = ( pedestrianDetectorStatusGroupNumber * 8) - 6 Bit 0: Det # = ( pedestrianDetectorStatusGroupNumber * 8) - 7 1.3.6.1.4.1.1206.4.2.1.2.9.1.2 S" ::= { pedestrianDetectorStatusGroupEntry 2 } pedestrianDetectorStatusGroupAlarms OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " This object shall return the alarm status of the pedestrian detectors associated with the group. Each pedestrian detector alarm status shall be represented as ON or OFF by individual bits in this object. If any pedestrian detector alarm (defined in the pedestrianDetectorAlarms object) is active the associated bit shall be set (1). If a pedestrian detector alarm is not active the associated bit shall be clear (0). Bit 7: Det # = ( pedestrianDetectorStatusGroupNumber * 8) Bit 6: Det # = ( pedestrianDetectorStatusGroupNumber * 8) - 1 Bit 5: Det # = ( pedestrianDetectorStatusGroupNumber * 8) - 2 Bit 4: Det # = ( pedestrianDetectorStatusGroupNumber * 8) - 3 Bit 3: Det # = ( pedestrianDetectorStatusGroupNumber * 8) - 4 Bit 2: Det # = ( pedestrianDetectorStatusGroupNumber * 8) - 5 Bit 1: Det # = ( pedestrianDetectorStatusGroupNumber * 8) - 6 Bit 0: Det # = ( pedestrianDetectorStatusGroupNumber * 8) - 7 1.3.6.1.4.1.1206.4.2.1.2.9.1.3 S" ::= { pedestrianDetectorStatusGroupEntry 3 } pedestrianDetectorReport OBJECT IDENTIFIER ::= { detector 10 } -- This node contains the objects necessary to support pedestrian -- detector reporting. pedestrianDetectorSequence OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " This object defines a Sequence Number for the pedestrian detector data collection. This object is used to detect duplicate or missing reports. The value cycles within the limits of 0 to 255. This object is incremented by one at the expiration of the pedestrianDetectorPeriod time. 1.3.6.1.4.1.1206.4.2.1.2.10.1 S sequence" ::= { pedestrianDetectorReport 1 } pedestrianDetectorPeriod OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION " This object defines the number of seconds (0- 3600 seconds) that comprise the pedestrian detector data collection period. When the collection period expires the device shall increment the pedestrianDetectorSequence, update the pedestrianSampleTable entries and reset the pedestrian volume timer. A value of 0 indicates that no sampling is to be performed. A value of 65534 indicates that the pedestrian detector data collection period is equal to vehicle sample period in effect. A value of 65535 indicates that the sample period equal to current cycle length recorded at local zero. If the sample period is configured to use the cycle length but the ASC is running in Free mode, then no data collection is performed. Value Indication 0 No pedestrian data collection is performed 1-3600 Pedestrian data collection period in seconds 3601-65533 Reserved 65534 Pedestrian data collection period is equal to the vehicle sample period in effect 65535 Pedestrian data collection period is same as cycle period recorded at local zero 1.3.6.1.4.1.1206.4.2.1.2.10.2 P second" ::= { pedestrianDetectorReport 2 } activePedestrianDetectors OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " The number of detectors in this device. This object indicates how many rows are in the pedestrianSampleTable object. There shall be a row for every pedestrian detector that is collecting pedestrian data. 1.3.6.1.4.1.1206.4.2.1.2.10.3 S detector" ::= { pedestrianDetectorReport 3 } pedestrianSampleTable OBJECT-TYPE SYNTAX SEQUENCE OF PedestrianSampleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table containing pedestrian data collected. The number of rows in this table is equal to the activePedestrianDetectors object. static 1.3.6.1.4.1.1206.4.2.1.2.10.4" ::= { pedestrianDetectorReport 4 } pedestrianSampleEntry OBJECT-TYPE SYNTAX PedestrianSampleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " The data collected for one of the detectors in the device as part of a pedestrian detector data collection. 1.3.6.1.4.1.1206.4.2.1.2.10.4.1" INDEX { pedestrianDetectorNumber } ::= { pedestrianSampleTable 1 } PedestrianSampleEntry ::= SEQUENCE { pedestrianDetectorVolume INTEGER, pedestrianDetectorActuations INTEGER, pedestrianDetectorServices INTEGER } pedestrianDetectorVolume OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " Pedestrian detector data collected over the data collection period. This value shall range from 0 to 254 indicating the volume of pedestrians crossing the associated pedestrian detector zone during the data collection period. The value 255 shall indicate volume overflow. 1.3.6.1.4.1.1206.4.2.1.2.10.4.1.1 S volume" ::= { pedestrianSampleEntry 1 } pedestrianDetectorActuations OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " Pedestrian actuations collected over the data collection period. The value of the object shall indicate pedestrian actuations or pedestrian detector diagnostic information as follows: Value Indication 0-200 Number of actuations 201 Number of actuations exceeds 200. 202-208 Reserved 209 Other Fault 210 Max Presence Fault 211 No Activity Fault 212 Reserved 213 Reserved 214 Reserved 215 Configuration Fault 216 Communications Fault 217 Erratic Output Fault 218-255 Reserved Faults shall be indicated for all collection periods during which a fault is detected if either pedestrian volume or pedestrian actuations is being collected. The highest numbered fault shall be presented if more than one fault is active (i.e. indicate OpenLoop rather than NoActivity). 1.3.6.1.4.1.1206.4.2.1.2.10.4.1.2 S volume" ::= { pedestrianSampleEntry 2 } pedestrianDetectorServices OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " The number of pedestrian services (number of times the ped transitioned from don't walk to walk) collected over the data collection period. This value shall range from 0- 254. A value of 255 indicates an overflow condition. 1.3.6.1.4.1.1206.4.2.1.2.10.4.1.3 S volume" ::= { pedestrianSampleEntry 3 } pedestrianDetectorSampleTime OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The local time expressed in seconds since 00:00:00 (midnight) January 1, 1970 of the same time offset, representing the end time of the last completed pedestrian detector data collection period. This value changes by 3600 seconds in response to a DST event. 1.3.6.1.4.1.1206.4.2.1.2.10.5 S second" ::= { pedestrianDetectorReport 5 } pedestrianDetectorSampleDuration OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION " This object indicates the number of seconds (1-3600 seconds) that comprise the duration of the pedestrian detector data collection period. A value of 0 indicates that duration is invalid. Values of 3601-65535 are reserved. 1.3.6.1.4.1.1206.4.2.1.2.10.6 S second" ::= { pedestrianDetectorReport 6 } maxVehicleDetectorControlGroups OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The maximum number of vehicle detector control groups (8 detectors per group) this device supports. This value is equal to TRUNCATE [(maxVehicleDetectors + 7 ) / 8]. This object indicates the maximum number of rows which shall appear in the vehicleDetectorControlGroupTable object. 1.3.6.1.4.1.1206.4.2.1.2.11 S group" ::= { detector 11 } vehicleDetectorControlGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF VehicleDetectorControlGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table containing vehicle detector control in groups of eight detectors. The number of rows in this table is equal to the maxVehicleDetectorControlGroups object. static 1.3.6.1.4.1.1206.4.2.1.2.12" ::= { detector 12 } vehicleDetectorControlGroupEntry OBJECT-TYPE SYNTAX VehicleDetectorControlGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A group (row) of vehicle detector controls. 1.3.6.1.4.1.1206.4.2.1.2.12.1" INDEX { vehicleDetectorControlGroupNumber } ::= { vehicleDetectorControlGroupTable 1 } VehicleDetectorControlGroupEntry ::= SEQUENCE { vehicleDetectorControlGroupNumber INTEGER, vehicleDetectorControlGroupActuation INTEGER } vehicleDetectorControlGroupNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The vehicle detector control group number for objects in this row. This value shall not exceed the maxVehicleDetectorControlGroups object value. 1.3.6.1.4.1.1206.4.2.1.2.12.1.1 S group" ::= { vehicleDetectorControlGroupEntry 1 } vehicleDetectorControlGroupActuation OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " This object is used to allow a remote entity to place an actuation on a vehicle detector. When a bit = 1, an actuation is placed on the vehicle detector. When a bit = 0, no actuation is placed on the vehicle detector. An NTCIP actuation is placed using this object and is treated the same as an external actuation, so all detector functions are still applicable, including delay, extension, diagnostics, and report objects, such as vehicleDetectorStatusGroupActive and volumeOccupancyReport. Bit 7: Det # = ( vehicleDetectorControlGroupNumber * 8) Bit 6: Det # = ( vehicleDetectorControlGroupNumber * 8) - 1 Bit 5: Det # = ( vehicleDetectorControlGroupNumber * 8) - 2 Bit 4: Det # = ( vehicleDetectorControlGroupNumber * 8) - 3 Bit 3: Det # = ( vehicleDetectorControlGroupNumber * 8) - 4 Bit 2: Det # = ( vehicleDetectorControlGroupNumber * 8) - 5 Bit 1: Det # = ( vehicleDetectorControlGroupNumber * 8) - 6 Bit 0: Det # = ( vehicleDetectorControlGroupNumber * 8) - 7 The device shall reset this object to ZERO when in BACKUP Mode. A write to this object shall reset the Backup timer to ZERO (see unitBackupTime). P 1.3.6.1.4.1.1206.4.2.1.2.12.1.2" ::= { vehicleDetectorControlGroupEntry 2 } pedestrianDetectorControlGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF PedestrianDetectorControlGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table containing pedestrian detector control in groups of eight detectors. The number of rows in this table is equal to the maxPedestrianDetectorGroups object. static 1.3.6.1.4.1.1206.4.2.1.2.13" ::= { detector 13 } pedestrianDetectorControlGroupEntry OBJECT-TYPE SYNTAX PedestrianDetectorControlGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A group (row) of pedestrian detector controls. 1.3.6.1.4.1.1206.4.2.1.2.13.1" INDEX { pedestrianDetectorControlGroupNumber } ::= { pedestrianDetectorControlGroupTable 1 } PedestrianDetectorControlGroupEntry ::= SEQUENCE { pedestrianDetectorControlGroupNumber INTEGER, pedestrianDetectorControlGroupActuation INTEGER } pedestrianDetectorControlGroupNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The pedestrian detector control group number for objects in this row. This value shall not exceed the maxPedestrianDetectorGroups object value. 1.3.6.1.4.1.1206.4.2.1.2.13.1.1 S group" ::= { pedestrianDetectorControlGroupEntry 1 } pedestrianDetectorControlGroupActuation OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " This object is used to allow a remote entity to place an actuation on a pedestrian detector. When a bit = 1, an actuation is placed on the pedestrian detector. When a bit = 0, no actuation is placed on the pedestrian detector. An NTCIP actuation is placed using this object and is treated the same as an external actuation, so all detector functions are still applicable, including delay, extension, diagnostics, and report objects, such as pedestrianDetectorStatusGroupActive and pedestrianDetectorReport. Bit 7: Det # = ( pedestrianDetectorControlGroupNumber * 8) Bit 6: Det # = ( pedestrianDetectorControlGroupNumber * 8) - 1 Bit 5: Det # = ( pedestrianDetectorControlGroupNumber * 8) - 2 Bit 4: Det # = ( pedestrianDetectorControlGroupNumber * 8) - 3 Bit 3: Det # = ( pedestrianDetectorControlGroupNumber * 8) - 4 Bit 2: Det # = ( pedestrianDetectorControlGroupNumber * 8) - 5 Bit 1: Det # = ( pedestrianDetectorControlGroupNumber * 8) - 6 Bit 0: Det # = ( pedestrianDetectorControlGroupNumber * 8) - 7 The device shall reset this object to ZERO when in BACKUP Mode. A write to this object shall reset the Backup timer to ZERO (see unitBackupTime). 1.3.6.1.4.1.1206.4.2.1.2.13.1.2 C" ::= { pedestrianDetectorControlGroupEntry 2 } unit OBJECT IDENTIFIER ::= { asc 3 } --This defines a node for supporting unit objects. unitStartUpFlash OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Unit Start up Flash time parameter in seconds (0 to 255 sec). The period/state (Start-Up Flash) occurs when power is restored following a device defined power interruption. During the Start-Up Flash state, the Fault Monitor and Voltage Monitor outputs shall be inactive (if present) and the Channel Flash settings shall be overridden. 1.3.6.1.4.1.1206.4.2.1.3.1 P second" REFERENCE "NEMA TS 2 Clause 3.9.1.1" ::= { unit 1 } unitAutoPedestrianClear OBJECT-TYPE SYNTAX INTEGER { disable(1), enable (2) } ACCESS read-write STATUS mandatory DESCRIPTION " Unit Automatic Ped Clear parameter (1 = False/Disable 2=True/Enable). When enabled, the CU shall time the Pedestrian Clearance interval when Manual Control Enable is active and prevent the Pedestrian Clearance interval from being terminated by the Interval Advance input. 1.3.6.1.4.1.1206.4.2.1.3.2 P" REFERENCE "NEMA TS 2 Clause 3.5.3.10" ::= { unit 2 } unitBackupTime OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION " The Backup Time in seconds (0-65535 sec). When any of the defined system control parameters is SET, the backup timer is reset. After reset the CU times the unitBackupTime interval. If the unitBackupTime interval expires without a SET operation to any of the system control parameters, then the CU shall revert to Backup Mode. A value of zero (0) for this object shall disable this feature. The setting of this object shall be ignored if the unitUserDefinedBackupTime is set to a non-zero value. The system control parameters are: phaseControlGroupPhaseOmit, phaseControlGroupPedOmit, phaseControlGroupHold, phaseControlGroupForceOff, phaseControlGroupVehCall, phaseControlGroupPedCall, systemPatternControl, systemSyncControl, preemptControlState, ringControlGroupStopTime, ringControlGroupForceOff, ringControlGroupMax2, ringControlGroupMaxInhibit, ringControlGroupPedRecycle, ringControlGroupRedRest, ringControlGroupOmitRedClear, unitControl, specialFunctionOutputState (deprecated), and specialFunctionOutputControl. These system control parameters are added for controllers that support 1202 v3 and above: ringControlGroupMax3 vehicleDetectorControlGroupActuation pedestrianDetectorControlGroupActuation actionPlanControl 1.3.6.1.4.1.1206.4.2.1.3.3 P second" ::= { unit 3 } unitRedRevert OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " The red revert in tenth seconds ( 0.0 - 25.5 sec). This value shall provide the minimum red revert time for all phases (i.e. if it is greater than a phaseRedRevert object value, then this value shall be used as the red revert time for the affected phase). This object provides a minimum Red indication following the Yellow Change interval and prior to the next display of Green on the same signal output driver group. 1.3.6.1.4.1.1206.4.2.1.3.4 P tenth second" ::= { unit 4 } unitControlStatus OBJECT-TYPE SYNTAX INTEGER { other (1), systemControl (2), systemStandby (3), backupMode(4), manual (5), timebase (6), interconnect (7), interconnectBackup (8), remoteManualControl (9), localManualControl (10) } ACCESS read-only STATUS mandatory DESCRIPTION " The Control Mode for Pattern, Flash, or Free at the device: other: control by a source other than those listed here. systemControl: control by master or central commands. systemStandby: control by local based on master or central command to use local control. backupMode: Backup Mode (see Terms). manual: control by entry other than zero in coordOperationalMode. timebase: control by the local Time Base. interconnect: control by the local Interconnect inputs. interconnectBackup: control by local TBC due to invalid Interconnect inputs or loss of sync. remoteManualControl: control by central command via remote MCE commands (See unitMCEIntAdv and unitMCETimeout). localManualControl: control via MCE and Interval Advance inputs (e.g., police panel) 1.3.6.1.4.1.1206.4.2.1.3.5 S" ::= { unit 5 } unitFlashStatus OBJECT-TYPE SYNTAX INTEGER { other(1), notFlash(2), automatic(3), localManual(4), faultMonitor(5), mmu(6), startup(7), preempt (8) } ACCESS read-only STATUS mandatory DESCRIPTION " The Flash modes: other: the CU is in flash for some other reason. notFlash: the CU is not in Flash automatic: the CU is currently in an Automatic Flash state. localManual: the Controller Unit Local Flash input is active, MMU Flash input is not active, and Flash is not commanded by the Master. faultMonitor: the CU is currently in a Fault Monitor State. mmu: the Controller Unit MMU Flash input is active and the CU is not in Start-Up Flash. startup: the CU is currently timing the Start-Up Flash period. preempt: the CU is currently timing the preempt Flash. 1.3.6.1.4.1.1206.4.2.1.3.6 S" ::= { unit 6 } unitAlarmStatus2 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " Device Alarm Mask 2 ( 0 = False, 1 = True) as follows: Bit 7: Process Failure - Whenever the CU detects a process (task) failure. Bit 6: Stall Condition - Whenever the CU detects a watchdog condition on any 'critical' watchdog. A 'critical' watchdog timer is any timer for a process or service that may jeopardize the safe operation of the ASC. Bit 5: Offset Transitioning - Whenever the CU is performing an offset transition (correction in process) Bit 4: Stop Time - When either CU Stop Time Input becomes active. Bit 3: External Start - When the CU External Start becomes active. Bit 2: Response Fault - When any NEMA TS2 Port 1 response frame fault occurs. Bit 1: Low Battery - When any battery voltage falls below the required level. Bit 0: Power Restart - When power returns after a power interruption. Once set, a bit shall maintain its state as long as the condition exists. Bit 0 (Power Restart) status shall be maintained until a READ of this object occurs. 1.3.6.1.4.1.1206.4.2.1.3.7 S" ::= { unit 7 } unitAlarmStatus1 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " Device Alarm Mask 1 ( 0 = False, 1 = True) as follows: Bit 7: CoordActive - When coordination is active and not preempted or overridden. Bit 6: Local Free - When any of the CU inputs and/or programming cause it not to run coordination. Bit 5: Local Flash - When the Controller Unit Local Flash input becomes active, MMU Flash input is not active, and Flash is not commanded by the system. Bit 4: MMU Flash - When the Controller Unit MMU Flash input remains active for a period of time exceeding the Start-Up Flash time. Bit 3: Cycle Fail - When a local Controller Unit is operating in the non-coordinated mode, whether the result of a Cycle Fault or Free being the current normal mode, and cycling diagnostics indicate that a serviceable call exists that has not been serviced for two cycles. Bit 2: Coord Fail - When a Coord Fault is in effect and a Cycle Fault occurs again within two cycles of the coordination retry. Bit 1: Coord Fault - When a Cycle Fault is in effect and the serviceable call has been serviced within two cycles after the Cycle Fault. Bit 0: Cycle Fault - When the Controller Unit is operating in the coordinated mode and cycling diagnostics indicate that a serviceable call exists that has not been serviced for two cycles. Once set, a bit shall maintain its state as long as the condition exists. 1.3.6.1.4.1.1206.4.2.1.3.8 S" ::= { unit 8 } shortAlarmStatus OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " Short Alarm Mask ( 0 = False, 1 = True) as follows: Bit 7: Critical Alarm - When the Stop Time input is active. Bit 6: Non-Critical Alarm - When an physical alarm input is active. Bit 5: Detector Fault - When any detectorAlarm fault occurs. Bit 4: Coordination Alarm - When the CU is not running the called pattern without offset correction within three cycles of the command. An offset correction requiring less than three cycles due to cycle overrun caused by servicing a pedestrian call shall not cause a Coordination Alarm. Bit 3: Local Override - When any of the CU inputs and/or programming cause it not to run coordination. Bit 2: Local Cycle Zero - When running coordinated and the Coord Cycle Status (coordCycleStatus) has passed through zero. Bit 1: T&F Flash - When either the Local Flash or MMU Flash input becomes active. Bit 0: Preempt - When any of the CU Preempt inputs become active. Once set, a bit shall maintain its state as long as the condition exists. Bit 2 (Local Cycle Zero) status shall be maintained until a READ of this object occurs. 1.3.6.1.4.1.1206.4.2.1.3.9 S" ::= { unit 9 } unitControl OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " This object is used to allow a remote entity to activate unit functions in the device ( 0 = False / Disabled, 1 = True / Enabled) as follows: Bit 7: Dimming Enable - when set to 1, causes channel dimming to operate as configured. For dimming to occur, (this control OR a dimming input) AND a 'timebaseAscAuxillaryFunction' must be True. REFERENCE NEMA TS 2 Clause 3.9.2 Bit 6: Interconnect - when set to 1, shall cause the interconnect inputs to operate at a higher priority than the timebase control (TBC On Line). REFERENCE NEMA TS 2 Clause 3.6.2.3 and 3.8.3 Bit 5: Walk Rest Modifier - when set to 1, causes non-actuated phases to remain in the timed-out Walk state (rest in Walk) in the absence of a serviceable conflicting call. REFERENCE NEMA TS 2 Clause 3.5.5.5.13 Bit 4: Call to Non-Actuated 2 - when set to 1, causes any phase(s) appropriately programmed in the phaseOptions object to operate in the Non-Actuated Mode. REFERENCE NEMA TS 2 Clause 3.5.5.5.8 Bit 3: Call to Non-Actuated 1 - when set to 1, causes any phase(s) appropriately programmed in the phaseOptions object to operate in the Non-Actuated Mode. REFERENCE NEMA TS 2 Clause 3.5.5.5.8 Bit 2: External Minimum Recall - when set to 1, causes a recurring demand on all vehicle phases for a minimum vehicle service. REFERENCE NEMA TS 2 Clause 3.5.5.5.9 Bit 1: Disable Remote Commands - when set to 1, causes a CU to ignore commands (all SET requests) from all management station except and until this bit is SET to 0 (i.e., a management station can still SET this bit to 0 to enable Remote Command). Bit 0: Reserved When a bit = 1, the device shall activate the Unit control. When a bit = 0, the device shall not activate the Unit control. A SET of a 'reserved' bit to a value other than zero (0) shall return a badValue(3) error. The device shall reset this object to ZERO when in BACKUP Mode. A write to this object shall reset the BACKUP timer (see unitBackupTime). 1.3.6.1.4.1.1206.4.2.1.3.10 P" ::= { unit 10 } maxAlarmGroups OBJECT-TYPE SYNTAX INTEGER(1..255) ACCESS read-only STATUS mandatory DESCRIPTION " This object contains the maximum number of alarm groups (8 alarm inputs per group) this device supports. This object indicates the maximum rows which shall appear in the alarmGroupTable object. 1.3.6.1.4.1.1206.4.2.1.3.11 S alarm Group" ::= { unit 11 } alarmGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF AlarmGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " This table contains alarm input status in groups of eight inputs. The number of rows in this table is equal to the maxAlarmGroups object. static 1.3.6.1.4.1.1206.4.2.1.3.12" ::= { unit 12 } alarmGroupEntry OBJECT-TYPE SYNTAX AlarmGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Status for eight alarm inputs. 1.3.6.1.4.1.1206.4.2.1.3.12.1" INDEX { alarmGroupNumber } ::= { alarmGroupTable 1 } AlarmGroupEntry::= SEQUENCE { alarmGroupNumber INTEGER, alarmGroupState INTEGER} alarmGroupNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The alarm group number for objects in this row. This value shall not exceed the maxAlarmGroups object value. 1.3.6.1.4.1.1206.4.2.1.3.12.1.1 S group" ::= { alarmGroupEntry 1 } alarmGroupState OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " Alarm input state bit field. When a bit = 1, the associated physical alarm input is active. When a bit = 0, the associated alarm input is NOT active. Bit 7: Alarm Input # = ( alarmGroupNumber * 8) Bit 6: Alarm Input # = ( alarmGroupNumber * 8) -1 Bit 5: Alarm Input # = ( alarmGroupNumber * 8) -2 Bit 4: Alarm Input # = ( alarmGroupNumber * 8) -3 Bit 3: Alarm Input # = ( alarmGroupNumber * 8) -4 Bit 2: Alarm Input # = ( alarmGroupNumber * 8) -5 Bit 1: Alarm Input # = ( alarmGroupNumber * 8) -6 Bit 0: Alarm Input # = ( alarmGroupNumber * 8) -7 1.3.6.1.4.1.1206.4.2.1.3.12.1.2 S" ::= {alarmGroupEntry 2 } maxSpecialFunctionOutputs OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The Maximum Number of Special Functions this Actuated Controller Unit supports. 1.3.6.1.4.1.1206.4.2.1.3.13 S output" ::= { unit 13 } specialFunctionOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF SpecialFunctionOutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table containing Actuated Controller Unit special function output objects. The number of rows in this table is equal to the maxSpecialFunctionOutputs object. static 1.3.6.1.4.1.1206.4.2.1.3.14" ::= { unit 14 } specialFunctionOutputEntry OBJECT-TYPE SYNTAX SpecialFunctionOutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Control for Actuated Controller Unit system special functions. 1.3.6.1.4.1.1206.4.2.1.3.14.1" INDEX { specialFunctionOutputNumber } ::= { specialFunctionOutputTable 1 } SpecialFunctionOutputEntry ::= SEQUENCE { specialFunctionOutputNumber INTEGER, specialFunctionOutputState INTEGER, -- deprecated specialFunctionOutputControl INTEGER, specialFunctionOutputStatus INTEGER } specialFunctionOutputNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The special function output number associated with object in this row. This value shall not exceed the maxSpecialFunctionOutputs object value. 1.3.6.1.4.1.1206.4.2.1.3.14.1.1 S output" ::= { specialFunctionOutputEntry 1 } specialFunctionOutputState OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-write STATUS deprecated DESCRIPTION " The special function output (logical or physical) on the device may be controlled by this object. When this object is non-zero then the associated special function output signal shall be ON. When this object is zero then the associated special function output signal shall be OFF A read of this object shall reflect the current state of the special function output. 1.3.6.1.4.1.1206.4.2.1.3.14.1.2" ::= { specialFunctionOutputEntry 2 } specialFunctionOutputControl OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-write STATUS mandatory DESCRIPTION " The special function output (logical or physical) in the device may be controlled by this object. 0 = OFF & 1 = ON. The device shall reset this object to ZERO when in BACKUP Mode. A write to this object shall reset the BACKUP timer (see unitBackupTime). 1.3.6.1.4.1.1206.4.2.1.3.14.1.3 P" ::= { specialFunctionOutputEntry 3 } specialFunctionOutputStatus OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-only STATUS mandatory DESCRIPTION " The current status (ON-OFF) of the special function output (logical or physical) in the device. 0 = OFF & 1 = ON. 1.3.6.1.4.1.1206.4.2.1.3.14.1.4 S" ::= { specialFunctionOutputEntry 4 } unitMCETimeout OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " This object performs two functions. First, it enables manual operation the same as the MCE controller input. Second, it serves as a timeout value for a failsafe. If the value is non-zero, remote manual control is enabled. When a SET to this object is performed, the controller shall load the value into a timer that decrements once per second. If the timer reaches zero or if the object is SET to zero by the management station, the controller shall automatically disable remote manual control. This forces the management station to continually refresh this timer to maintain remote manual operation. When in remote manual mode, the controller should respond exactly as if the MCE input was active. 1.3.6.1.4.1.1206.4.2.1.3.15 C" ::= { unit 15 } unitMCEIntAdv OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-write STATUS mandatory DESCRIPTION " This objects acts as a remote interval advance function. When SET to 1, the controller will behave as if the Interval Advance input (a.k.a. police 'pickle') was toggled. When remote manual control mode is enabled (see unitMCETimeout) the controller shall advance to the next interval and reset the value of this object to 0. If this object is SET to 1 when the controller is not in remote manual control mode, the controller shall return an error of 3 (bad value). 1.3.6.1.4.1.1206.4.2.1.3.16 C" ::= { unit 16 } ascElevationOffset OBJECT-TYPE SYNTAX INTEGER (0..31) ACCESS read-write STATUS mandatory DESCRIPTION " The offset in height, in meters, from the antenna of a GNSS or similar geopositioning device to the base of CU cabinet. It is assumed that the antenna is at a height higher than the base of the CU structure. Values of 0 to 30 provides a range from 0 meters to 30 meters. The value of 31 represents unknown. 1.3.6.1.4.1.1206.4.2.1.3.17 P meters" DEFVAL { 31 } ::= { unit 17 } unitStartUpFlashMode OBJECT-TYPE SYNTAX INTEGER { autoFlash (1), allRedFlashOverride (2), allRedControllerFlash (3) } ACCESS read-write STATUS mandatory DESCRIPTION " Defines the startup flash state for the unit. For autoFlash (1), the startup flash state for each signal indication is also the state of the channel during Automatic Flash mode. For allRedFlashOverride (2), during the Start-Up Flash state, the Fault Monitor and Voltage Monitor outputs shall be inactive (if present) and the Channel Flash settings shall be overridden. For allRedControllerFlash(3), the load switch flash would flash all red regardless of the auto flash channel configuration. P 1.3.6.1.4.1.1206.4.2.1.3.18" DEFVAL { autoFlash } ::= { unit 18 } unitUserDefinedBackupTime OBJECT-TYPE SYNTAX INTEGER (0..16777216) ACCESS read-write STATUS mandatory DESCRIPTION " The Backup Time in seconds (0-16777216 sec) in 1-second increments. When any of the user-defined system control parameters is SET, the user-defined backup timer is reset. After reset, the CU times the unitUserDefinedBackupTime period. If the unitUserDefinedBackupTime period expires without a SET operation to any of the user-defined control parameters defined in unitUserDefinedBackupTimeContent, then the CU reverts to Backup Mode. A value of zero (0) for this object shall disable this feature. If the value of this object is non-zero, then all functionality related to unitBackupTime is diabled. 1.3.6.1.4.1.1206.4.2.1.3.19 P second" DEFVAL {300} ::= { unit 19 } maxUserDefinedBackupTimeContent OBJECT-TYPE SYNTAX INTEGER (2..255) ACCESS read-only STATUS mandatory DESCRIPTION " The Maximum Number of user content backup time contents this controller supports. This object indicates the maximum rows which shall appear in the unitUserDefinedBackupTimeContentTable object. 1.3.6.1.4.1.1206.4.2.1.3.20 S phase" ::= { unit 20 } unitUserDefinedBackupTimeContentTable OBJECT-TYPE SYNTAX SEQUENCE OF UnitUserDefinedBackupTimeContentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table containing the parameters of the user defined parameters for the backup timer. static 1.3.6.1.4.1.1206.4.2.1.3.21" ::= { unit 21 } unitUserDefinedBackupTimeContentEntry OBJECT-TYPE SYNTAX UnitUserDefinedBackupTimeContentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Parameters for a user-defined backup timer. 1.3.6.1.4.1.1206.4.2.1.3.21.1" INDEX { unitUserDefinedBackupTimeContentNumber } ::= { unitUserDefinedBackupTimeContentTable 1 } UnitUserDefinedBackupTimeContentEntry ::= SEQUENCE { unitUserDefinedBackupTimeContentNumber INTEGER, unitUserDefinedBackupTimeContentOID OBJECT IDENTIFIER, unitUserDefinedBackupTimeContentDescription OCTET STRING } unitUserDefinedBackupTimeContentNumber OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION " A userDefinedBackupTimeContent number for objects in this row. The value shall not exceed maxUserDefinedBackupTimeContents object value. 1.3.6.1.4.1.1206.4.2.1.3.21.1.1 S number" ::= { unitUserDefinedBackupTimeContentEntry 1 } unitUserDefinedBackupTimeContentOID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-write STATUS mandatory DESCRIPTION " This object contains a reference to the function, which, if any SET operation is performed on it, leads to a reset of the timer associated with the unitUserDefinedbackupTime object. This object shall reference the function by its associated identifier including its instance (i.e., the full OID of the scalar or columnar object). 1.3.6.1.4.1.1206.4.2.1.3.21.1.2 P" ::= { unitUserDefinedBackupTimeContentEntry 2 } unitUserDefinedBackupTimeContentDescription OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION " Contains a text description of the referenced function that, if performing a SET command against its corresponding object, will reset the timer associated with the unitUserDefinedBackupTime object. 1.3.6.1.4.1.1206.4.2.1.3.21.1.3 P" DEFVAL { "" } ::= { unitUserDefinedBackupTimeContentEntry 3 } ascClock OBJECT IDENTIFIER ::= { unit 22 } -- This note contains the objects necessary to support time sources. maxTimeSources OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The maximum number of time sources that this Controller Unit supports. This object indicates the maximum rows which shall appear in the unitTimeTable object. 1.3.6.1.4.1.1206.4.2.1.3.22.1 S timeSource" ::= { ascClock 1 } unitTimeTable OBJECT-TYPE SYNTAX SEQUENCE OF UnitTimeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table containing Controller Unit time sources. The number of rows in this table is equal to the maxTimeSources object. static 1.3.6.1.4.1.1206.4.2.1.3.22.2" ::= { ascClock 2 } unitTimeEntry OBJECT-TYPE SYNTAX UnitTimeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Parameters for a specific Controller Unit time source. 1.3.6.1.4.1.1206.4.2.1.3.22.2.1" INDEX { unitTimeIndex } ::= { unitTimeTable 1 } UnitTimeEntry ::= SEQUENCE { unitTimeIndex INTEGER, unitTimeSourceAvailable INTEGER } unitTimeIndex OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The index number for objects in this row. The value shall not exceed the maxTimeSources object value. 1.3.6.1.4.1.1206.4.2.1.3.22.2.1.1 S timeSource" ::= { unitTimeEntry 1 } unitTimeSourceAvailable OBJECT-TYPE SYNTAX INTEGER { other (1), lineSync (2), rtcSqwr (3), crystal (4), gnss (5), ntp (6) } ACCESS read-only STATUS mandatory DESCRIPTION " An enumerated value representing the available sources for adjusting the clock. This object sets up the clock sources available for use by the CU. other: the source of the unit time is not defined by this standard. lineSync: the source of the unit time is determined by tracking the (AC) power line frequency rtcSqwr: the source of the unit time a Real Time Clock Square Wave output crystal: the source of the unit time is the internal crystal. This might also be used if the unit time normally uses line frequency but appears to be drifting too much as might happen when on a power generator. gnss: a GNSS device is being used to update the unit's internal reference on a frequent basis (e.g., once per minute)) ntp: the network time protocol (NTP) is being used to update the unit's internal reference 1.3.6.1.4.1.1206.4.2.1.3.22.2.1.2 S" DEFVAL { lineSync } ::= { unitTimeEntry 2 } unitTimeSourceCommanded OBJECT-TYPE SYNTAX INTEGER { other (1), lineSync (2), rtcSqwr (3), crystal (4), gnss (5), ntp (6) } ACCESS read-write STATUS mandatory DESCRIPTION " Commands the unit to the primary source for adjusting the unit clock: other: the source of the unit time is not defined by this standard. lineSync: the source of the unit time is determined by tracking the (AC) power line frequency rtcSqwr: the source of the unit time a Real Time Clock Square Wave output crystal: the source of the unit time is the internal crystal. This might also be used if the unit time normally uses line frequency but appears to be drifting too much as might happen when on a power generator. gnss: a GNSS device is being used to update the unit's internal reference on a frequent basis (e.g., once per minute)) ntp: the network time protocol (NTP) is being used to update the unit's internal reference 1.3.6.1.4.1.1206.4.2.1.3.22.3 P" DEFVAL { lineSync } ::= { ascClock 3 } unitTimeSourceCurrent OBJECT-TYPE SYNTAX INTEGER { other (1), lineSync (2), rtcSqwr (3), crystal (4), gnss (5), ntp (6) } ACCESS read-only STATUS mandatory DESCRIPTION " An enumerated value representing the current source for adjusting the unit clock as follows: other: the source of the unit time is not defined by this standard. lineSync: the source of the unit time is determined by tracking the (AC) power line frequency rtcSqwr: the source of the unit time is a Real Time Clock Square Wave output crystal: the source of the unit time is the internal crystal. This might also be used if the unit time normally uses line frequency but appears to be drifting too much as might happen when on a power generator. gnss: a GNSS device is being used to update the unit's internal reference on a frequent basis (e.g., once per minute)) ntp: the network time protocol (NTP) is being used to update the unit's internal reference 1.3.6.1.4.1.1206.4.2.1.3.22.4 S" DEFVAL { lineSync } ::= { ascClock 4 } unitTimeSourceStatus OBJECT-TYPE SYNTAX INTEGER { notActive (1), active (2), dataError (3), dataTimeOutError (4), pendingUpdate (5), nonSequential (6) } ACCESS read-only STATUS mandatory DESCRIPTION " An enumerated value representing the status of the current unit clock source (unitTimeSourceCurrent). notActive: The unit is not monitoring this clock source, or updates are not available. active: The unit is receiving valid updates and is updating the controller time without errors. dataError: A data error, such as a crc mismatch, was detected. dataTimeoutError: No data has been received from the unitTimeSourceCurrent within a reasonable amount of time. This timeout will be preset by the driver for this time source as it depends on the specific implementation. pendingUpdate: The unit is pending an update from the unitTimeSourceCurrent, such as when the controller is in the startup period and is waiting for the external device to sync to its reference and send the time to the unit. nonSequential: A non-sequential clock change occurrence. Note this value should be cleared upon reading it (i.e., a GET on this object) or 10 seconds after its occurrence, whichever comes first. 1.3.6.1.4.1.1206.4.2.1.3.22.5 S" ::= { ascClock 5 } unitTimeNonSequentialSource OBJECT-TYPE SYNTAX INTEGER { unknown (1), dstChange (2), managementStation (3), localUser (4), timeSourceChange (5), timeSourceDiscontinuity (6) } ACCESS read-only STATUS mandatory DESCRIPTION " An enumerated value that indicates the source of a non-sequential change to the ASC clock time. A non- sequential change occurs anytime the clock changes by more than 1 increment (whether in seconds or milliseconds). unknown: the source of the non-sequential change to the unit time is unknown or cannot be determined. dstChange: the source of the non-sequential change to the unit time is a change in daytime savings time. managementStation: the source of the non-sequential change to the unit time is a command from a management station. localUser: the source of the non-sequential change to the unit time is a command from a user or device at the controller unit. timeSourceChange: A change in the time source (e.g., external1) timeSourceDiscontinuity: A change as determined by an external time source (e.g., GNSS). The value is latched until another non-sequential change to the ASC clock time or until the ASC is powered off. If a non-sequential change occurs or globalTime is SET, then the event should be logged. This object is used with the unitTimeNonSequentialChange and the unitTimeNonSequentialDelta objects. 1.3.6.1.4.1.1206.4.2.1.3.22.6 S" DEFVAL { unknown } ::= { ascClock 6 } unitTimeNonSequentialChange OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " The 'new' globalTime after a non-sequential change to the ASC clock time. A non-sequential change occurs anytime the clock changes by more than 1 increment (whether in seconds or milliseconds). The value of this object is number of seconds since the epoch of 00:00:00 (midnight) January 1, 1970 UTC (a.k.a. Zulu or GMT). 1.3.6.1.4.1.1206.4.2.1.3.22.7 S second" DEFVAL { 0 } ::= { ascClock 7 } unitTimeNonSequentialDelta OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0 | 5)) ACCESS read-only STATUS mandatory DESCRIPTION " An octet string indicating the difference between the 'expected' time and the new time for the ASC clock after a non- sequential change to the ASC clock. A non-sequential change occurs anytime the clock changes by more than 1 increment (whether in seconds or milliseconds). A positive value indicates time jumped ahead while a negative value indicates time jumped back. The first octet is from -23 to +23 hours, the second octet is in minutes, the third octet represents seconds, and the last two octets represents milliseconds. This object is used with the unitTimeNonSequentialSource and the unitTimeNonSequentialChange objects. 1.3.6.1.4.1.1206.4.2.1.3.22.8 S" DEFVAL { "" } ::= { ascClock 8 } commPorts OBJECT IDENTIFIER ::= { unit 23 } -- This node shall contain objects that configure, monitor or -- control communications ports functions for this device. maxCommPorts OBJECT-TYPE SYNTAX INTEGER (1..16) ACCESS read-only STATUS mandatory DESCRIPTION " The Maximum Number of communications Ports this device supports and is the maximum value of ifNumber allowed. 1.3.6.1.4.1.1206.4.2.1.3.23.1 S commPorts" ::= { commPorts 1 } commPortTable OBJECT-TYPE SYNTAX SEQUENCE OF CommPortsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table used to describe and configure the communication ports on the CU. The number of rows in this table is equal to the maxCommPorts object. static 1.3.6.1.4.1.1206.4.2.1.3.23.2" ::= { commPorts 2 } commPortsEntry OBJECT-TYPE SYNTAX CommPortsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " This object defines a row in the Communication Ports Table which is used to extend the ifTable of RFC 1213. It uses ifIndex from RFC 1213 as the index, so all communications ports in the controller has to be included in the ifTable including async RS232 ports which are also in the rs232PortTable. 1.3.6.1.4.1.1206.4.2.1.3.23.2.1" INDEX { ifIndex } ::= { commPortTable 1 } CommPortsEntry ::= SEQUENCE { commPortType INTEGER, commPortTypeIndex INTEGER, commPortEnable INTEGER, commPortProtocolsSupported INTEGER, commPortProtocol INTEGER, commPortDiagnostics INTEGER } commPortType OBJECT-TYPE SYNTAX INTEGER { other (1), ethernet (2), rs232like (3) } ACCESS read-only STATUS mandatory DESCRIPTION " This object identifies the port type. Although RFC 1213 contains ifType, this object provides the user/device further guidance to additional objects that define the port and its configuration. The valid port types are defined as follows: other: the port type is not defined by this standard. Ethernet: the port type is Ethernet based (i.e. IP) and configured per NTCIP 2104 and 2202 rs232like: the port type is rs-232-like (per RFC 1317) and may be either an asynchronous or synchronous serial. Port configuration is contained in RFC 1317 rs232PortTable 1.3.6.1.4.1.1206.4.2.1.3.23.2.1.1 S" ::= { commPortsEntry 1 } commPortTypeIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " This object contains the value to be used as the index into the appropriate communication port configuration table. If commPortType = rs232like, then this value is used for RFC 1317 rs232PortIndex into the rs232PortTable. If commPortType is ethernet then this object is redundant and should have the same value as ifIndex. 1.3.6.1.4.1.1206.4.2.1.3.23.2.1.2 S" ::= { commPortsEntry 2 } commPortEnable OBJECT-TYPE SYNTAX INTEGER { enabled (1), disabled (2) } ACCESS read-write STATUS mandatory DESCRIPTION " This object is used to enable/disable a communications port on the device unless prohibited by the hardware specification or hardware standard. Unused communications port numbers shall be set to disabled (2), and by default, all available communications ports shall be disabled. A GET of this object returns the current state of the port. Note that the device may include other means to disable a communications port (e.g. Port 1 Disable input). Attempting to enable a port that is disabled by these other means will fail and a subsequent GET of this object will indicate that the port is still disabled. 1.3.6.1.4.1.1206.4.2.1.3.23.2.1.3 C" ::= { commPortsEntry 3 } commPortProtocolsSupported OBJECT-TYPE SYNTAX INTEGER (0.. 4294967295) ACCESS read-only STATUS mandatory DESCRIPTION " This object identifies the protocols supported by the port. If a protocol is supported on the port, then the bit is set to 1, otherwise the bit is set to zero (0). Bits 6 - 31: Reserved Bit 5: Console Bit 4: Serial Bus #3 Bit 3: Serial Bus #1 Bit 2: Port 1 Bit 1: NTCIP Bit 0: Other protocol not defined in this standard A SET of a 'reserved' bit to a value other than zero (0) shall return a badValue(3) error. 1.3.6.1.4.1.1206.4.2.1.3.23.2.1.4 S" ::= { commPortsEntry 4 } commPortProtocol OBJECT-TYPE SYNTAX INTEGER (0..32) ACCESS read-write STATUS mandatory DESCRIPTION " This object specifies the protocol to be used on the communication port. If the port is disabled by means other than commPortEnable or has not yet been initialized, then the protocol shall be zero (0); otherwise the value shall be set to n+1 where n is the bit number within commPortProtocolsSupported of the protocol desired. Note that one can only choose from the set of protocols supported on that port; all other values will return a badValue response. 1.3.6.1.4.1.1206.4.2.1.3.23.2.1.5 P" ::= { commPortsEntry 5 } commPortDiagnostics OBJECT-TYPE SYNTAX INTEGER { normal (1), loopback (2), echomode (3) } ACCESS read-write STATUS mandatory DESCRIPTION " This object specifies the port diagnostic commands for a communication port. It works in conjunction with ifOperStatus and ifAdminStatus from RFC 1213. Setting this object to loopback or echomode will result in ifAdminStatus being set to 'testing' and if successful the device will update ifOperStatus to testing. When ifAdminStatus is set to either 'up' or 'down', if successful the device will update ifOperStatus accordingly and set this object to 'normal'. One cannot directly set this object to 'normal'. Note that a user can enable/disable each communications port on the device unless prohibited by the PRL or hardware standard/specification. Unused communications port numbers shall be set to disabled ('down'), and by default, all available communications ports shall be enabled. Note that the device may include other means to disable a communications port (e.g. Port 1 Disable input). Attempting to enable a port that is disabled by these other means will fail and a subsequent GET of this object will indicate that the port is still disabled. 1.3.6.1.4.1.1206.4.2.1.3.23.2.1.6 P" ::= { commPortsEntry 6 } maxEthernetPorts OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The Maximum Number of Ethernet communications ports this device supports. This object indicates the maximum rows which shall appear in the ethernetConfigTable object. 1.3.6.1.4.1.1206.4.2.1.3.23.3 S ethernetPorts" ::= { commPorts 3 } ethernetConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF EthernetConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " This table extends configurations for the Ethernet ports on the device by providing objects that extend standard configuration tables such as those contained in RFC 1213. The number of rows in this table is equal to the maxEthernetPorts object. This table only contains rows for communication ports with commPortType = ethernet (2). Note that the Ethernet port's MAC address can be found via the ifPhysAddress object in the ifTable at the same value of ifIndex. static 1.3.6.1.4.1.1206.4.2.1.3.23.4" ::= { commPorts 4 } ethernetConfigEntry OBJECT-TYPE SYNTAX EthernetConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " This object defines a row in the Ethernet Port Configuration Table. 1.3.6.1.4.1.1206.4.2.1.3.23.4.1" INDEX { ifIndex } ::= { ethernetConfigTable 1 } EthernetConfigEntry ::= SEQUENCE { ecfgIpAddr IpAddress, ecfgNetMask IpAddress, ecfgGateway IpAddress, ecfgDNS IpAddress, ecfgMode INTEGER, ecfgLogicalName OCTET STRING, ecfgStaticIpAddr IpAddress, ecfgStaticNetMask IpAddress, ecfgStaticGateway IpAddress, ecfgStaticDNS IpAddress } ecfgIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION " This object contains the IP address of this logical Ethernet Port. 1.3.6.1.4.1.1206.4.2.1.3.23.4.1.1 S" ::= { ethernetConfigEntry 1 } ecfgNetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION " This object contains the network mask for this Ethernet Port. 1.3.6.1.4.1.1206.4.2.1.3.23.4.1.2 S" ::= { ethernetConfigEntry 2 } ecfgGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION " This object contains the gateway IP address for this Ethernet Port. 1.3.6.1.4.1.1206.4.2.1.3.23.4.1.3 S" ::= { ethernetConfigEntry 3 } ecfgDNS OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION " This object contains the domain name server IP address for this Ethernet Port. 1.3.6.1.4.1.1206.4.2.1.3.23.4.1.4 S" ::= { ethernetConfigEntry 4 } ecfgMode OBJECT-TYPE SYNTAX INTEGER { other (1), static (2), dHCPclient (3) } ACCESS read-write STATUS mandatory DESCRIPTION " This object determines how the IPv4 interface is configured: other: the interface is configured with some other mechanism not defined by this standard static: the interface is configured using the static values in this table dHCPclient: the interface is configured via DHCP request 1.3.6.1.4.1.1206.4.2.1.3.23.4.1.5 P" ::= { ethernetConfigEntry 5 } ecfgLogicalName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION " This object contains the Logical Name used for this port if DHCP client is enabled. If DHCP client is disabled then this object contains the last Logical Name used for this port (if none, then the object would be a zero length octet string). 1.3.6.1.4.1.1206.4.2.1.3.23.4.1.6 P" ::= { ethernetConfigEntry 6 } ecfgStaticIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION " This object contains the IP address to be used for this logical Ethernet Port if the ecfgMode object is static (2). 1.3.6.1.4.1.1206.4.2.1.3.23.4.1.7" ::= { ethernetConfigEntry 7 } ecfgStaticNetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION " This object contains the network mask to be used for this Ethernet Port if the ecfgMode object is static (2). 1.3.6.1.4.1.1206.4.2.1.3.23.4.1.8 P" ::= { ethernetConfigEntry 8 } ecfgStaticGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION " This object contains the gateway IP address to be used for this Ethernet Port if the ecfgMode object is static (2). 1.3.6.1.4.1.1206.4.2.1.3.23.4.1.9 P" ::= { ethernetConfigEntry 9 } ecfgStaticDNS OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION " This object contains the domain name server IP address to be used for this Ethernet Port if the ecfgMode object is static (2). 1.3.6.1.4.1.1206.4.2.1.3.23.4.1.10 P" ::= { ethernetConfigEntry 10 } -- To support the Ethernet protocol running at any of the -- defined communications ports, the object definitions -- contained in the following tables within -- Annex I shall be supported: -- SNMP Group -- System Group -- Interfaces Group -- IP Group -- ICMP Group -- TCP Group -- UDP Group -- Ethernet Group -- See Annex I for object definitions to be supported. -- To support the asynchronous, serial protocol running at -- any of the defined communications ports, the object -- definitions contained in the following tables within -- Annex I shall be supported: -- SNMP Group -- System Group -- RS232 Group -- HDLC Group -- Interfaces Group -- See Annex I for object definitions to be supported. -- To support the synchronous, serial protocol running at -- any of the defined communications ports, the object -- definitions contained in the following tables within -- Annex I shall be supported: -- SNMP Group -- System Group -- RS232 Group -- HDLC Group -- Interfaces Group -- See Annex I for object definitions to be supported. port1TimeoutFault OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " This object is the number of Port 1 Timeout Faults during the previous 24 hour period. CUs which do not support a Port 1 Timeout Fault shall report a value of 255. A value of 254 shall indicate 254 or more timeouts during the previous 24 hour period. 1.3.6.1.4.1.1206.4.2.1.3.23.8 S" REFERENCE "NEMA TS 2 Section 4.4.6" DEFVAL { 255 } ::= { commPorts 8 } serialBus1Fault OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " This object is the number of Serial Bus 1 timeout failures measured during the previous 24 hour period. CUs which do not support a Serial Bus 1 Timeout Failures shall report a value of 255. A value of 254 shall indicate 254 or more timeouts during the previous 24 hour period. 1.3.6.1.4.1.1206.4.2.1.3.23.9 S" REFERENCE "ITS Cabinet Standard v01.02.17b Section 4.4.6.3.1." DEFVAL { 255 } ::= { commPorts 9 } maxGlobalSetIds OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION " The maximum number of object identifiers that can be used to create the value of the globalSetIDParameter as supported by this CU. S 1.3.6.1.4.1.1206.4.2.1.3.24" ::= { unit 24 } globalSetIdTable OBJECT-TYPE SYNTAX SEQUENCE OF GlobalSetIdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " This table contains the object identifiers used to create the globalSetIDParameter. The number of rows within this table shall not exceed the value of maxGlobalSetIds. If the rows within this table are defined, the OIDs shall be used in order, as indicated by the globalSetIdNumber, to create the value of the globalSetIDParameter object. The algorithm used to create the actual value of the globalSetIDParameter is not defined by this standard, but may be a CRC algorithm. If there are no rows defined within this table, then the value of the globalSetIDParameter object shall be created as defined in NTCIP 1201v03, Section 2.2.1. static 1.3.6.1.4.1.1206.4.2.1.3.25" ::= { unit 25 } globalSetIdEntry OBJECT-TYPE SYNTAX GlobalSetIdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " This object defines a row in the globalSetIdTable. 1.3.6.1.4.1.1206.4.2.1.3.25.1" INDEX { globalSetIdNumber } ::= { globalSetIdTable 1 } GlobalSetIdEntry ::= SEQUENCE { globalSetIdNumber INTEGER, globalSetIdOID OBJECT IDENTIFIER } globalSetIdNumber OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION " The global ID number for objects in this row. This value shall not exceed maxGlobalSetIds. 1.3.6.1.4.1.1206.4.2.1.3.25.1.1 S" ::= { globalSetIdEntry 1 } globalSetIdOID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-write STATUS mandatory DESCRIPTION " This object contains one of the object identifiers that are to be used to create the value of the globalSetIDParameter. A value of NULL indicates no further object identifiers will be used to determine the globalSetIDParameter (i.e., end of the list of object identifiers). 1.3.6.1.4.1.1206.4.2.1.3.25.1.2 P" ::= { globalSetIdEntry 2 } unitAlarmStatus3 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " Device Alarm Mask 3 ( 0 = False, 1 = True) as follows: Bit 7: Reserved Bit 6: Reserved Bit 5: CV Certificate = Whenever the CU detects a fault related to invalid connected vehicle certificates. Bit 4: Power Issues = Whenever the CU detects power issues such as brown-outs or brief black outs but do not lead to a shutdown of the CU Bit 3: RSU Link Status = Whenever the CU is configured to communicate with a RSU but the communications link is failed (e.g., timeouts, errors). Bit 2: UPS Link Status = Whenever the CU is configured to communicate with a UPS but the communications link is failed (e.g., timeouts, errors). Bit 1: CMU Link Status = Whenever the CU is configured to communicate with CMU but the communication link is failed (e.g., timeouts, errors). Bit 0: Communications Timeout = Whenever the CU detects a communications timeout on an enabled communications port on the ASC. Once set, a bit shall maintain its state as long as the condition exists. 1.3.6.1.4.1.1206.4.2.1.3.26 S" ::= { unit 26 } unitAlarmStatus4 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " Device Alarm Mask 4 ( 0 = False, 1 = True) as follows: Bit 7: Reserved Bit 6: Reserved Bit 5: USB = Whenever the CU detects a USB memory device. Bit 4: Scheduler = Whenever the CU is not implementing a scheduled pattern or scheduled action. Bit 3: Clock = Whenever the CU detects an error with the CU's internal clock. Bit 2: Cabinet Environmental Sensors = Whenever the cabinet environmental conditions measured by the CU exceeds the thresholds (e.g., temperature, humidity). Bit 1: Preempt Maximum Presence - Preempt maximum presence time exceeded Bit 0: Memory Fault = Whenever the CU detects a memory fault within the controller unit, such as in the firmware, a database or RAM. 1.3.6.1.4.1.1206.4.2.1.3.27 S" ::= { unit 27 } coord OBJECT IDENTIFIER ::= { asc 4 } -- The coord node contains objects that support coordination -- configuration, status and control functions for the device. coordOperationalMode OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " This object defines the operational mode for coordination. The possible modes are: Value DESCRIPTION 0 Automatic - this mode provides for coord operation, free, and flash to be determined automatically by the possible sources (i.e. Interconnect, Time Base, or System Commands). 1-253 Manual Pattern - these modes provides for Coord operation running this pattern. This selection of pattern overrides all other pattern commands. 254Manual Free - this mode provides for Free operation without coordination or Automatic Flash from any source. 255 Manual Flash - this mode provides for Automatic Flash without coordination or Free from any source. 1.3.6.1.4.1.1206.4.2.1.4.1 P" REFERENCE "NEMA TS 2 Clause 3.6.2.4" ::= { coord 1 } coordCorrectionMode OBJECT-TYPE SYNTAX INTEGER { other (1), dwell (2), shortway (3), addOnly (4), subtractOnly (5) } ACCESS read-write STATUS mandatory DESCRIPTION " This object defines the Coord Correction Mode. The possible modes are: other: the coordinator establishes a new offset by a mechanism not defined in this standard. dwell: when changing offset, the coordinator shall establish a new offset by dwelling in the coord phase(s) until the desired offset is reached. shortway (Smooth): when changing offset, the coordinator shall establish a new offset by adding or subtracting to/from the timings in a manner that limits the cycle change. This operation is performed in a device specific manner. addOnly: when changing offset, the coordinator shall establish a new offset by adding to the timings in a manner that limits the cycle change. This operation is performed in a device specific manner. subtractOnly: when changing offset, the coordinator shall establish a new offset by subtracting from the timings in a manner that limits the cycle change. This operation is performed in a device specific manner. 1.3.6.1.4.1.1206.4.2.1.4.2 P" ::= { coord 2 } coordMaximumMode OBJECT-TYPE SYNTAX INTEGER { other (1), maximum1 (2), maximum2 (3), maxInhibit (4), maximum3 (5) } ACCESS read-write STATUS mandatory DESCRIPTION "This object defines the Coord Maximum Mode. The possible modes are: other: the maximum mode is determined by some other mechanism not defined in this standard. maximum1: the internal Maximum 1 Timing shall be effective while coordination is running a pattern. maximum2: the internal Maximum 2 Timing shall be effective while coordination is running a pattern. maxInhibit: the internal Maximum Timing shall be inhibited while coordination is running a pattern. maximum3: the internal Maximum 3 Timing shall be effective while coordination is running a pattern. 1.3.6.1.4.1.1206.4.2.1.4.3 P" ::= { coord 3 } coordForceMode OBJECT-TYPE SYNTAX INTEGER { other(1), floating (2), fixed (3) } ACCESS read-write STATUS mandatory DESCRIPTION " This object defines the Pattern Force Mode. The possible modes are: other: the CU implements a mechanism not defined in this standard. floating: each non-coord phase will be forced to limit its time to the split time value. This allows unused split time to revert to the coord phase. fixed: each non-coord phase will be forced at a fixed position in the cycle. This allows unused split time to revert to the following phase. 1.3.6.1.4.1.1206.4.2.1.4.4 P" ::= { coord 4 } maxPatterns OBJECT-TYPE SYNTAX INTEGER (1..253) ACCESS read-only STATUS mandatory DESCRIPTION " The maximum number of Patterns this Controller Unit supports. This object indicates how many rows are in the patternTable object (254 and 255 are defined as non- pattern Status for Free and Flash). 1.3.6.1.4.1.1206.4.2.1.4.5 S pattern" ::= { coord 5 } patternTableType OBJECT-TYPE SYNTAX INTEGER { other (1), patterns (2), offset3 (3), offset5 (4) } ACCESS read-only STATUS mandatory DESCRIPTION " This object provides information about any special organizational structure required for the pattern table. The defined structures are as follows: other: The pattern table setup is not described in this standard, refer to device manual. patterns: Each row of the pattern table represents a unique pattern and has no dependencies on other rows. offset3: The pattern table is organized into plans which have three offsets. Each plan uses three consecutive rows. Only patternOffsetTime and patternSequenceNumber values may vary between each of the three rows. Plan 1 is contained in rows 1, 2 and 3, Plan 2 is contained in rows 4, 5 and 6, Plan 3 is in rows 7, 8 and 9, etc. offset5: The pattern table is organized into plans which have five offsets. Each plan occupies five consecutive rows. Only patternOffsetTime and patternSequenceNumber values may vary between each of the rows. Plan 1 is contained in rows 1, 2, 3, 4 and 5, Plan 2 is contained in rows 6, 7, 8, 9 and 10, Plan 3 is contained in rows 11, 12, 13, 14 and 15, etc. 1.3.6.1.4.1.1206.4.2.1.4.6 S" REFERENCE "NEMA TS 2 Clause 3.6.2.1 and 3.6.2.2" ::= { coord 6 } patternTable OBJECT-TYPE SYNTAX SEQUENCE OF PatternEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table containing Actuated Controller Unit coordination Pattern parameters. The number of rows in this table is equal to the maxPatterns object. static 1.3.6.1.4.1.1206.4.2.1.4.7" ::= { coord 7 } patternEntry OBJECT-TYPE SYNTAX PatternEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Parameters for a specific Actuated Controller Unit pattern. 1.3.6.1.4.1.1206.4.2.1.4.7.1" INDEX { patternNumber } ::= { patternTable 1 } PatternEntry ::= SEQUENCE { patternNumber INTEGER, patternCycleTime INTEGER, patternOffsetTime INTEGER, patternSplitNumber INTEGER, patternSequenceNumber INTEGER, patternCoordSyncPoint INTEGER, patternOptions INTEGER, patternSpatEnabledLanes OCTET STRING } --deprecrated patternNumber OBJECT-TYPE SYNTAX INTEGER (1..253) ACCESS read-only STATUS mandatory DESCRIPTION " The pattern number for objects in this row. This value shall not exceed the maxPatterns object value. 1.3.6.1.4.1.1206.4.2.1.4.7.1.1 S pattern" ::= { patternEntry 1 } patternCycleTime OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " The patternCycleTime object specifies the length of the pattern cycle in seconds (NEMA TS 2 range: 30-255). A pattern cycle time less than adequate to service the minimum requirements of all phases shall result in Free mode. While this condition exists, the Local Free bit of unitAlarmStatus1 and the Local Override bit of shortAlarmStatus shall be set to one (1). The minimum requirements of a phase with a not-actuated ped include Minimum Green, Walk, Pedestrian Clear, Yellow Clearance, and Red Clearance; the minimum requirements of a phase with an actuated pedestrian include Minimum Green, Yellow Clearance, and Red Clearance. If the pattern cycle time is zero and the associated split table (if any) contains values greater than zero, then the CU shall utilize the split time values as maximum values for each phase. 1.3.6.1.4.1.1206.4.2.1.4.7.1.2 P second" REFERENCE "NEMA TS 2 Clause 3.6.2.1.1" ::= { patternEntry 2 } patternOffsetTime OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " The patternOffsetTime defines by how many seconds (NEMA TS 2 range: 0-254) the local time zero shall lag the system time zero (synchronization pulse) for this pattern. An offset value equal to or greater than the patternCycleTime shall result in Free being the operational mode. While this condition exists, the Local Free bit of unitAlarmStatus1 and the LocalOverride bit of shortAlarmStatus shall be set to one (1). 1.3.6.1.4.1.1206.4.2.1.4.7.1.3 P second" REFERENCE "NEMA TS 2 Clause 3.6.2.2" ::= { patternEntry 3 } patternSplitNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION " This object is used to locate information in the splitTable to use for this pattern. This value shall not exceed the maxSplits object value. 1.3.6.1.4.1.1206.4.2.1.4.7.1.4 P split" ::= { patternEntry 4 } patternSequenceNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION " This object is used to locate information in the sequenceTable to use with this pattern. This value shall not exceed the maxSequences object value. 1.3.6.1.4.1.1206.4.2.1.4.7.1.5 P sequence" ::= { patternEntry 5 } patternCoordSyncPoint OBJECT-TYPE SYNTAX INTEGER { other (1), unitCoordSyncPoint (2), firstCoordPhsGrnBegin (3), lastCoordPhsGrnBegin (4), firstCoordPhsGrnEnd (5), lastCoordPhsGrnEnd (6), firstCoordPhsYelEnd (7), lastCoordPhsYelEnd (8) } ACCESS read-write STATUS mandatory DESCRIPTION " This object is used to indicate the location of the system reference point for this pattern. The valid coordination sync points are: other: the coordination sync point is not described in this standard unitCoordSyncPoint: the coordination point is defined by unitCoordSyncPoint. firstCoordPhsGrnBegin: the coordination point is the beginning of the Green indication of the first coordinated phase. lastCoordPhsGrnBegin: the coordination point is the beginning of the Green indication of the last coordinated phase. firstCoordPhsGrnEnd: the coordination point is end of the green indication of the first coordinated phase. lastCoordPhsGrnEnd: the coordination point is the end of the green indication of the last coordinated phase. firstCoordPhsYelEnd: the coordination point is the end of the yellow indication of the first coordinated phase. lastCoordPhsYelEnd: the coordination point is the end of the yellow indication of the last coordinated phase. 1.3.6.1.4.1.1206.4.2.1.4.7.1.6 P" DEFVAL { firstCoordPhsGrnBegin } ::= { patternEntry 6 } patternOptions OBJECT-TYPE SYNTAX INTEGER { other (1), coordMaximumMode (2), maxInhibit (3), maximum1 (4), maximum2 (5), maximum3 (6) } ACCESS read-write STATUS mandatory DESCRIPTION " This object represents the maximum mode to be used for the pattern. The valid maximum modes are: other: the maximum mode is determined by some other mechanism not defined in this standard. coordMaximumMode: use the maximum mode defined by the coordMaximumMode object. maxInhibit: the internal maximum timing shall be inhibited while coordination is running this pattern. maximum1: the internal Maximum 1 Timing shall be effective while coordination is running this pattern. maximum2: the internal Maximum 2 Timing shall be effective while coordination is running this pattern. maximum3: the internal Maximum 3 Timing shall be effective while coordination is running this pattern. 1.3.6.1.4.1.1206.4.2.1.4.7.1.7 P" ::= { patternEntry 7 } patternSpatEnabledLanes OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS deprecated DESCRIPTION " Each octet in this octet string represents the index of the lanes (mapLaneIndex) that are activated for the current MAP plan in effect(xxxx). Each indexed lane should have its revocable Lane bit set (Bit 0 set to (1) in the mapLaneAttribute object). 1.3.6.1.4.1.1206.4.2.1.4.7.1.8" ::= { patternEntry 8 } maxSplits OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The maximum number of Split Plans this Actuated Controller Unit supports. This object indicates how many Split plans are in the splitTable object. 1.3.6.1.4.1.1206.4.2.1.4.8 S split" ::= { coord 8 } splitTable OBJECT-TYPE SYNTAX SEQUENCE OF SplitEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table containing Actuated Controller Unit coordination split parameters. The number of rows in this table is equal to maxSplits. static 1.3.6.1.4.1.1206.4.2.1.4.9" ::= { coord 9 } splitEntry OBJECT-TYPE SYNTAX SplitEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Split type Parameters for a specific Actuated Controller Unit phase. 1.3.6.1.4.1.1206.4.2.1.4.9.1" INDEX { splitNumber, splitPhase } ::= { splitTable 1 } SplitEntry ::= SEQUENCE { splitNumber INTEGER, splitPhase INTEGER, splitTime INTEGER, splitMode INTEGER, splitCoordPhase INTEGER, splitOptions INTEGER } splitNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The object defines which rows of the split table comprise a split group. All rows that have the same splitNumber are in the same split group. The value of this object shall not exceed the maxSplits object value. 1.3.6.1.4.1.1206.4.2.1.4.9.1.1 S split" ::= { splitEntry 1 } splitPhase OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The phase number for objects in this row. The value of this object shall not exceed the maxPhases object value. 1.3.6.1.4.1.1206.4.2.1.4.9.1.2 S phase" ::= { splitEntry 2 } splitTime OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " The time in seconds the splitPhase is allowed to receive (i.e. before a Force Off is applied) when constant demands exist on all phases. In floating coordForceMode, this is always the maximum time a non-coordinated phase is allowed to receive. In fixed coordForceMode, the actual allowed time may be longer if a previous phase gapped out. The splitTime includes all phase clearance times for the associated phase. The split time shall be longer than the sum of the phase minimum service requirements for the phase. When the time is NOT adequate to service the minimum service requirements of the phase, Free Mode shall be the result. The minimum requirements of a phase with a not-actuated ped include Minimum Green, Walk, Pedestrian Clear, Yellow Clearance, and Red Clearance; the minimum requirements of a phase with an actuated pedestrian include Minimum Green, Yellow Clearance, and Red Clearance. If the cycleTime entry of the associated patternTable entry is zero (i.e. the device is in Free Mode), then the value of this object shall be applied, if non-zero, as a maximum time for the associated phase. If the critical path through the phase diagram is less than the cycleTime entry of the associated patternTable entry, all extra time is allotted to the coordination phase in each ring. If the critical path through the phase diagram is greater than the cycleTime entry of the associated patternTable entry (and the cycleTime is not zero) the device shall operate in the Free Mode. While the Free Mode condition exists, the Local Override bit of shortAlarm shall be set to one (1). 1.3.6.1.4.1.1206.4.2.1.4.9.1.3 P second" REFERENCE "NEMA TS 2 Clause 3.6.2.1.2" ::= { splitEntry 3 } splitMode OBJECT-TYPE SYNTAX INTEGER { other(1), none (2), minimumVehicleRecall (3), maximumVehicleRecall (4), pedestrianRecall (5), maximumVehicleAndPedestrianRecall (6), phaseOmitted (7), nonActuated (8) } ACCESS read-write STATUS mandatory DESCRIPTION " This object defines operational characteristics of the phase. The following options are available: other: the operation is not specified in this standard none: no split mode control. minimumVehicleRecall: this phase operates with a minimum vehicle recall. maximumVehicleRecall: this phase operates with a maximum vehicle recall. This value shall also be used for bicycle phase recalls and transit phase recalls. pedestrianRecall: this phase operates with a pedestrian recall. maximumVehicleAndPedestrianRecall: this phase operates with a maximum vehicle & pedestrian recall. phaseOmitted: this phase is omitted. nonActuated: this phase operates with a fixed split time. 1.3.6.1.4.1.1206.4.2.1.4.9.1.4 P" ::= { splitEntry 4 } splitCoordPhase OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-write STATUS mandatory DESCRIPTION " To select the associated phase as a coordinated phase this object shall be set to TRUE (non zero). 1.3.6.1.4.1.1206.4.2.1.4.9.1.5" ::= { splitEntry 5 } splitOptions OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Optional split functions (0 = False/Disabled, 1 = True/Enabled). Bit 7: Reserved Bit 6: Reserved Bit 5: Reserved Bit 4: Reserved Bit 3: Reserved Bit 2: Reserved Bit 1: Reserved Bit 0: Transition Phase Omit - To allow the associated phase to be omitted during coord Correction Mode (transitions), this object shall be set to TRUE (1). If the associated phase is not allowed to be omitted, this object shall be set to FALSE (0). A SET of a 'reserved' bit to a value other than zero (0) shall return a badValue(3) error. 1.3.6.1.4.1.1206.4.2.1.4.9.1.6 P" ::= { splitEntry 6 } coordPatternStatus OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " This object defines the running coordination pattern/mode in the device. The possible values are: Value Description 0 Not used 1-253 Pattern - indicates the currently running pattern 254 Free - indicates Free operation without coordination. 255 Flash - indicates Automatic Flash without coordination. 1.3.6.1.4.1.1206.4.2.1.4.10 S" ::= { coord 10 } localFreeStatus OBJECT-TYPE SYNTAX INTEGER { other(1), notFree(2), commandFree(3), transitionFree(4), inputFree(5), coordFree(6), badPlan(7), badCycleTime(8), splitOverrun (9), invalidOffset (10), failed(11) } ACCESS read-only STATUS mandatory DESCRIPTION " The Free modes: other: Some other condition has caused the device to run in free mode. notFree: The unit is not running in free mode. commandFree: the current pattern command is the Free mode pattern. transitionFree: the CU has a pattern command but is cycling to a point to begin coordination. inputFree: one of the CU inputs cause it to not respond to coordination. coordFree: the CU programming for the called pattern is to run Free. badPlan: Free - the called pattern is invalid. badCycleTime: the pattern cycle time is less than adequate to service the minimum requirements of all phases. splitOverrun: Free - the sum of the critical path splitTime's exceed the programmed patternCycleTime value. invalidOffset: Free - reserved / not used failed: cycling diagnostics have called for Free. An ASC may provide diagnostics beyond those stated herein. Therefore, for a set of given bad data, the free status between devices may be inconsistent. 1.3.6.1.4.1.1206.4.2.1.4.11 S" ::= { coord 11 } coordCycleStatus OBJECT-TYPE SYNTAX INTEGER (0..510) ACCESS read-only STATUS mandatory DESCRIPTION " The Coord Cycle Status represents the current position in the local coord cycle of the running pattern (0 to 510 sec). This value normally counts down from patternCycleTime to Zero. This value may exceed the patternCycleTime during a coord cycle with offset correction (patternCycleTime + correction). 1.3.6.1.4.1.1206.4.2.1.4.12 S second" ::= { coord 12 } coordSyncStatus OBJECT-TYPE SYNTAX INTEGER (0..510) ACCESS read-only STATUS mandatory DESCRIPTION " The Coord Sync Status represents the time since the system reference point for the running pattern (0 to 510 sec). This value normally counts up from Zero to the next system reference point (patternCycleTime). This value may exceed the patternCycleTime during a coord cycle in which the system reference point has changed. 1.3.6.1.4.1.1206.4.2.1.4.13 S second" ::= { coord 13 } systemPatternControl OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " This object is used to establish the Called System Pattern/Mode for the device. The possible values are: Value DESCRIPTION 0 Standby - the system relinquishes control of the device. 1-253 Pattern - these values indicate the system commanded pattern 254 Free - this value indicates a call for Free 255 Flash - this value indicates a call for Automatic Flash If an unsupported / invalid pattern is called, Free shall be the operational mode. The device shall reset this object to ZERO when in BACKUP Mode. A write to this object shall reset the Backup timer to ZERO (see unitBackupTime). 1.3.6.1.4.1.1206.4.2.1.4.14 P" ::= { coord 14 } systemSyncControl OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " This object is used to establish the system reference point for the Called System Pattern by providing the current position in the system pattern cycle (0-254 sec). The device shall recognize a write to this object as a command to establish the time until the next system reference point. Thereafter, the system reference point shall be assumed to occur at a frequency equal to the patternCycleTime. When the value in the object is 255, the system REFERENCE point shall be referenced to the local Time Base in accordance with its programming. This CU must maintain an accuracy of 0.1 seconds based on the receipt of the SET packet. The device shall reset this object to ZERO when in BACKUP Mode. A write to this object shall reset the Backup timer to ZERO (see unitBackupTime). 1.3.6.1.4.1.1206.4.2.1.4.15 P second" ::= { coord 15 } unitCoordSyncPoint OBJECT-TYPE SYNTAX INTEGER { other (1), firstPhaseGreenBegin (2), lastPhaseGreenBegin (3), firstPhaseGreenEnd (4), lastPhaseGreenEnd (5), firstPhaseYellowEnd (6), lastPhaseYellowEnd (7) } ACCESS read-write STATUS mandatory DESCRIPTION " This object is used to indicate the location of the system reference point for the running pattern. The valid coordination sync points are: other: the coordination sync point is not described in this standard firstPhaseGreenBegin: the coordination point is the beginning of the Green indication of the first coordinated phase. lastPhaseGreenBegin: the coordination point is the beginning of the Green indication of the last coordinated phase. firstPhaseGreenEnd: the coordination point is end of the green indication of the first coordinated phase. lastPhaseGreenEnd: the coordination point is the end of the green indication of the last coordinated phase. firstPhaseYellowEnd: the coordination point is the end of the yellow indication of the first coordinated phase. lastPhaseYellowEnd: the coordination point is the end of the yellow indication of the last coordinated phase. 1.3.6.1.4.1.1206.4.2.1.4.16 P" DEFVAL { firstPhaseGreenBegin } ::= { coord 16 } timebaseAsc OBJECT IDENTIFIER ::= { asc 5 } -- This object is an identifier used to group all objects for -- support of timebase functions. If a device implements timebase -- functions then these objects shall be supported. timebaseAscPatternSync OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION " Pattern Sync Reference in minutes past midnight. When the value is 65535, the controller unit shall use the Action time as the Sync Reference for that pattern. Action time is the hour and minute associated with the active dayPlanEventNumber (as defined in NTCIP 1201). 1.3.6.1.4.1.1206.4.2.1.5.1 P minute" REFERENCE "NEMA TS 2 Clause 3.8.2" ::= { timebaseAsc 1 } maxTimebaseAscActions OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The Maximum Number of Actions this device supports. This object indicates the maximum rows which shall appear in the timebaseAscActionTable object. 1.3.6.1.4.1.1206.4.2.1.5.2 S action" ::= { timebaseAsc 2 } timebaseAscActionTable OBJECT-TYPE SYNTAX SEQUENCE OF TimebaseAscActionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table containing Actuated Controller Unit Time Base action parameters. The number of rows in this table is equal to the maxTimebaseAscActions object. static 1.3.6.1.4.1.1206.4.2.1.5.3" ::= { timebaseAsc 3 } timebaseAscActionEntry OBJECT-TYPE SYNTAX TimebaseAscActionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Action Parameters for a Actuated Controller Unit Time Base Program. 1.3.6.1.4.1.1206.4.2.1.5.3.1" INDEX { timebaseAscActionNumber } ::= { timebaseAscActionTable 1 } TimebaseAscActionEntry ::= SEQUENCE { timebaseAscActionNumber INTEGER, timebaseAscPattern INTEGER, timebaseAscAuxiliaryFunction INTEGER, timebaseAscSpecialFunction INTEGER, timebaseAscEnabledLane INTEGER } timebaseAscActionNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The time base Action number for objects in this row. This value shall not exceed the maxTimebaseAscActions object value. This object may be defined as a dayPlanActionOID (as defined in NTCIP 1201). 1.3.6.1.4.1.1206.4.2.1.5.3.1.1 S action" ::= { timebaseAscActionEntry 1 } timebaseAscPattern OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " The Pattern that shall be active when this Action is active. The value shall not exceed the value of maxPatterns, except for flash or free. A pattern of zero indicates that no pattern is being selected. A pattern = 0 relinquishes control to entity of a lower priority than timebase and allows that entity to control (i.e., interconnect if available). 1.3.6.1.4.1.1206.4.2.1.5.3.1.2 P pattern" ::= { timebaseAscActionEntry 2 } timebaseAscAuxiliaryFunction OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " The Auxiliary functions that shall be active when this Action is active. Bit 7: Reserved Bit 6: Reserved Bit 5: Reserved Bit 4: Reserved Bit 3: Dimming enabled if set (non-zero), disabled if clear (zero). For dimming to occur, this control AND ('unitControl' OR a dimming input) must be True. Bit 2: Auxiliary Function 3 enabled if set (non-zero), disabled if clear (zero). Bit 1: Auxiliary Function 2 enabled if set (non-zero), disabled if clear (zero). Bit 0: Auxiliary Function 1 enabled if set (non-zero), disabled if clear (zero). A SET of a 'reserved' bit to a value other than zero (0) shall return a badValue(3) error. 1.3.6.1.4.1.1206.4.2.1.5.3.1.3 P" ::= { timebaseAscActionEntry 3 } timebaseAscSpecialFunction OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " The Special Functions that shall be active when this Action is active. Bit 7: Special Function 8 Bit 6: Special Function 7 Bit 5: Special Function 6 Bit 4: Special Function 5 Bit 3: Special Function 4 Bit 2: Special Function 3 Bit 1: Special Function 2 Bit 0: Special Function 1 Bit = 0 - False/Disabled, Bit = 1 - True/Enabled 1.3.6.1.4.1.1206.4.2.1.5.3.1.4" ::= { timebaseAscActionEntry 4 } timebaseAscEnabledLane OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " This value is equal to the enabledLaneIndex (row) in the spatEnabledLanesConcurrencyTable that contains the enabledLaneConcurrency lanes to be active when this Action is active. A value of zero indicates that no lanes are to be be enabled as part of this action. 1.3.6.1.4.1.1206.4.2.1.5.3.1.4 P" ::= { timebaseAscActionEntry 5 } timebaseAscActionStatus OBJECT-TYPE SYNTAX INTEGER(0..255) ACCESS read-only STATUS mandatory DESCRIPTION " This object indicates the current time base Action Table row that will be used when the CU is in Time Base operation. A value of zero indicates that no time base Action is selected. 1.3.6.1.4.1.1206.4.2.1.5.4 S" ::= { timebaseAsc 4 } actionPlanControl OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " This object is used to activate a configured action plan by referencing the Action number (timebaseAscActionNumber). When this action plan is in effect, the CU shall operate as if the action plan has been activated by the time base scheduler. A value of 0 shall deactivate the action plan and returns to what would normally have been in operation if the action plan was not in effect. If an unsupported / invalid Action number is called, Free shall be the operational mode. The device shall reset this object to ZERO when in BACKUP Mode. A write to this object shall reset the Backup timer to ZERO (see unitBackupTime). 1.3.6.1.4.1.1206.4.2.1.5.5 C" DEFVAL { 0 } ::= { timebaseAsc 5 } preempt OBJECT IDENTIFIER ::= { asc 6 } -- The preempt node contains objects that support preempt input -- functions for the device. maxPreempts OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The Maximum Number of Preempts this Actuated Controller Unit supports. This object indicates the maximum rows which shall appear in the preemptTable object. 1.3.6.1.4.1.1206.4.2.1.6.1 S preempt" REFERENCE "NEMA TS 2 Clause 3.7" ::= { preempt 1 } preemptTable OBJECT-TYPE SYNTAX SEQUENCE OF PreemptEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table containing Actuated Controller Unit preemption parameters. The number of rows in this table is equal to the maxPreempts object. static 1.3.6.1.4.1.1206.4.2.1.6.2" ::={ preempt 2 } preemptEntry OBJECT-TYPE SYNTAX PreemptEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Parameters for a specific Actuated Controller Unit preemptor. 1.3.6.1.4.1.1206.4.2.1.6.2.1" INDEX { preemptNumber } ::={ preemptTable 1} PreemptEntry ::= SEQUENCE { preemptNumber INTEGER, preemptControl INTEGER, preemptLink INTEGER, preemptDelay INTEGER, preemptMinimumDuration INTEGER, preemptMinimumGreen INTEGER, preemptMinimumWalk INTEGER, preemptEnterPedClear INTEGER, preemptTrackGreen INTEGER, preemptDwellGreen INTEGER, preemptMaximumPresence INTEGER, preemptTrackPhase OCTET STRING, preemptDwellPhase OCTET STRING, preemptDwellPed OCTET STRING, preemptExitPhase OCTET STRING, preemptState INTEGER, preemptTrackOverlap OCTET STRING, preemptDwellOverlap OCTET STRING, preemptCyclingPhase OCTET STRING, preemptCyclingPed OCTET STRING, preemptCyclingOverlap OCTET STRING, preemptEnterYellowChange INTEGER, preemptEnterRedClear INTEGER, preemptTrackYellowChange INTEGER, preemptTrackRedClear INTEGER, preemptSequenceNumber INTEGER, preemptExitType INTEGER } preemptNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The preempt number for objects in this row. The value shall not exceed the maxPreempts object value. When all preemptControl objects have a value where bit 2 = 0, each preemptNumber routine shall be a higher priority and override all preemptNumber routines that have a larger preemptNumber. When a preemptControl object has a value where bit 2 = 1, the next higher preemptNumber becomes of equal priority with the preemptNumber but may still be a higher priority than larger preemptNumbers depending on bit 2 of the relavent preemptControl objects. 1.3.6.1.4.1.1206.4.2.1.6.2.1.1 S preempt" ::= { preemptEntry 1 } preemptControl OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Preempt Miscellaneous Control Parameter Mask (Bit=0: False/Disabled, Bit=1: True/Enabled) as follows: Bit 7: Reserved Bit 6: Reserved Bit 5: All Red Flash - the CU shall enter to all red flash instead of normal operations when the preemptMaximumPresence is exceeded Bit 4: Preempt Enable - enables or disables this preemption input. Disabling preempts should be done with extreme caution. Bit 3: Flash Dwell - the CU shall cause the phases listed in the preemptDwellPhase object to flash Yellow during the Dwell interval. All active phases not listed in preemptDwellPhase shall flash Red. The CU shall cause the overlaps listed in the preemptDwellOverlap object to flash Yellow during the Dwell state. All active overlaps not listed in preemptDwellOverlap shall flash Red. Preempt cycling phase programming is ignored if this bit is set. This control is optional. Bit 2: Preempt Override preemptNumber + 1 - provide a means to define whether this preempt shall NOT override the next higher numbered Preempt. When set (1) this preempt shall not override the next higher numbered preempt. Lowered numbered preempts override higher numbered preempts. For example, 1 overrides 3, and the only way to get 3 equal to 1, is to set both 1 and 2 to NOT override the next higher numbered preempt. This parameter shall be ignored when preemptNumber equals maxPreempts. Bit 1: Preempt Override Flash - provide a means to define whether this preempt shall NOT override Automatic Flash. When set (1) this preempt shall not override Automatic Flash. Bit 0: Non-Locking Memory - provide a means to enable an operation which does not require detector memory. When set (1) a preempt sequence shall not occur if the preempt input terminates prior to expiration of the preemptDelay time. A SET of a 'reserved' bit to a value other than zero (0) shall return a badValue(3) error. Support for Preempt Enable and All Red Flash added in NTCIP 1202 v03. 1.3.6.1.4.1.1206.4.2.1.6.2.1.2 P" REFERENCE "NEMA TS 2 Clause 3.7.2.1 and 3.7.2.2" DEFVAL { 0 } ::= { preemptEntry 2 } preemptLink OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " This object provides a means to define a higher priority preempt to be combined (linked) with this preempt. At the end of preemptDwellGreen, the linked preempt shall receive an automatic call that shall be maintained as long as the demand for this preempt is active. Any value that is not a higher priority preempt or a valid preempt shall be ignored. The value shall not exceed the maxPreempts object value. 1.3.6.1.4.1.1206.4.2.1.6.2.1.3 P preempt" DEFVAL { 0 } ::= { preemptEntry 3 } preemptDelay OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION " Preempt Delay Time in seconds (0-600 sec). This value determines the time the preempt input shall be active prior to initiating any preempt sequence. A non-locking preempt input which is removed prior to the completion of this time shall not cause a preempt sequence to occur. 1.3.6.1.4.1.1206.4.2.1.6.2.1.4 P second" DEFVAL { 0 } ::= { preemptEntry 4 } preemptMinimumDuration OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION " Preempt Minimum Duration Time in seconds (0..65535 sec). This value determines the minimum time during which the preempt is active. Duration begins timing at the end of Preempt Delay (if non zero) and will prevent an exit from the Dwell interval until this time has elapsed. 1.3.6.1.4.1.1206.4.2.1.6.2.1.5 P second" DEFVAL { 0 } ::= { preemptEntry 5 } preemptMinimumGreen OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Preempt Minimum Green Time in seconds (0-255 sec). A preempt initiated transition shall not cause the termination of an existing Green prior to its display for lesser of the phase's Minimum Green time or this period. CAUTION - if this value is zero, phase Green is terminated immediately. 1.3.6.1.4.1.1206.4.2.1.6.2.1.6 P second" DEFVAL { 255 } ::= { preemptEntry 6 } preemptMinimumWalk OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Preempt Minimum Walk Time in seconds (0-255 sec). A preempt initiated transition shall not cause the termination of an existing Walk prior to its display for the lesser of the phase's Walk time or this period. CAUTION - if this value is zero, phase Walk is terminated immediately. 1.3.6.1.4.1.1206.4.2.1.6.2.1.7 P second" DEFVAL { 255 } ::= { preemptEntry 7 } preemptEnterPedClear OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Enter Ped ClearTime in seconds (0-255 sec). This parameter controls the ped clear timing for a normal Walk signal terminated by a preempt initiated transition. A preempt initiated transition shall not cause the termination of a Pedestrian Clearance prior to its display for the lesser of the phase's Pedestrian Clearance time or this period. CAUTION - if this value is zero, phase Ped Clear is terminated immediately. 1.3.6.1.4.1.1206.4.2.1.6.2.1.8 P second" DEFVAL { 255 } ::= { preemptEntry 8 } preemptTrackGreen OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Track Clear Green Time in seconds (0-255 sec). This parameter controls the green timing for the track clearance movement. Track Clear phase(s) are enabled in the preemptTrackPhase object. If this value is zero, the track clearance movement is omitted, regardless of preemptTrackPhase programming. 1.3.6.1.4.1.1206.4.2.1.6.2.1.9 P second" DEFVAL { 0 } ::= { preemptEntry 9 } preemptDwellGreen OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Minimum Dwell interval in seconds (1-255 sec). This parameter controls the minimum timing for the dwell interval. Phase(s) active during the Dwell interval are enabled in preemptDwellPhase and preemptCyclingPhase objects. The Dwell interval shall not terminate prior to the completion of preemptMinimumDuration, preemptDwellGreen (this object), and the call is no longer present. 1.3.6.1.4.1.1206.4.2.1.6.2.1.10 P second" DEFVAL { 10 } ::= { preemptEntry 10 } preemptMaximumPresence OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION " Preempt Maximum Presence time in seconds (0- 65535 sec). This value determines the maximum time which a preempt call may remain active and be considered valid. When the preempt call has been active for this time period, the CU shall return to normal operation. This preempt call shall be considered invalid until such time as a change in state occurs (no longer active). When set to zero the preempt maximum presence time is disabled. 1.3.6.1.4.1.1206.4.2.1.6.2.1.11 P second" DEFVAL { 0 } ::= { preemptEntry 11 } preemptTrackPhase OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION " Each octet within the octet string contains a phaseNumber(binary value) that shall be active during the Preempt Track Clear intervals. The values of phaseNumber used here shall not exceed maxPhases or violate the Consistency Checks defined in Section 4.3.2. 1.3.6.1.4.1.1206.4.2.1.6.2.1.12 P2" DEFVAL { "" } ::= { preemptEntry 12 } preemptDwellPhase OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION " Each octet within the octet string contains a phaseNumber (binary value) that specifies the phase(s) to be served in the Preempt Dwell interval. The phase(s) defined in preemptCyclingPhase shall occur after those defined herein. The values of phaseNumber used here shall not exceed maxPhases or violate the Consistency Checks defined in Section 4.3.2. 1.3.6.1.4.1.1206.4.2.1.6.2.1.13 P2" DEFVAL { "" } ::= { preemptEntry 13 } preemptDwellPed OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION " Each octet within the octet string contains a phaseNumber (binary value) that specifies the pedestrian movement(s) to be served in the Preempt Dwell interval. The peds defined in preemptCyclingPed shall occur after those defined herein. The values of phaseNumber used here shall not exceed maxPhases or violate the Consistency Checks defined in Section 4.3.2. 1.3.6.1.4.1.1206.4.2.1.6.2.1.14 P2" DEFVAL { "" } ::= { preemptEntry 14 } preemptExitPhase OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION " Each octet within the octet string contains a phaseNumber (binary value) that shall be active following Preempt. The values of phaseNumber used here shall not exceed maxPhases or violate the Consistency Checks defined in Section 4.3.2. 1.3.6.1.4.1.1206.4.2.1.6.2.1.15 P2" DEFVAL { "" } ::= { preemptEntry 15 } preemptState OBJECT-TYPE SYNTAX INTEGER { other (1), notActive (2), notActiveWithCall (3), entryStarted (4), trackService (5), dwell (6), linkActive (7), exitStarted (8), maxPresence (9), advancedPreempt (10) } ACCESS read-only STATUS mandatory DESCRIPTION " Preempt State provides status on which state the associated preempt is in. The states are as follows: other: preempt service is not specified in this standard. notActive: preempt input is not active, this preempt is not active. notActiveWithCall: preempt input is active, preempt service has not started. entryStarted: preempt service is timing the entry intervals. trackService: preempt service is timing the track intervals. dwell: preempt service is timing the dwell intervals. linkActive: preempt service is performing linked operation. exitStarted: preempt service is timing the exit intervals. maxPresence: preempt input has exceeded maxPresence time advancedPreempt: preempt service is timing the advanced preemption time. 1.3.6.1.4.1.1206.4.2.1.6.2.1.16 S" ::= { preemptEntry 16} preemptTrackOverlap OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION " Each octet within the octet string contains a overlapNumber (binary value) that shall be active during the Preempt Track Clear intervals. The values of overlapNumber used here shall not exceed maxOverlaps or violate the consistency checks defined in Section 4.3.2. 1.3.6.1.4.1.1206.4.2.1.6.2.1.17 P2" DEFVAL { "" } ::= { preemptEntry 17 } preemptDwellOverlap OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION " Each octet within the octet string contains a overlapNumber (binary value) that is allowed during the Preempt Dwell interval. The values of overlapNumber used here shall not exceed maxOverlaps or violate the consistency checks defined in Section 4.3.2. 1.3.6.1.4.1.1206.4.2.1.6.2.1.18 P2" DEFVAL { "" } ::= { preemptEntry 18 } preemptCyclingPhase OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION " Each octet within the octet string contains a phaseNumber (binary value) that is allowed to cycle during the Preempt Dwell interval. The values of phaseNumber used here shall not exceed maxPhases or violate the Consistency Checks defined in Section 4.3.2. 1.3.6.1.4.1.1206.4.2.1.6.2.1.19 P2" DEFVAL { "" } ::= { preemptEntry 19 } preemptCyclingPed OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION " Each octet within the octet string contains a phaseNumber (binary value) indicating a pedestrian movement that is allowed to cycle during the Preempt Dwell interval. The values of phaseNumber used here shall not exceed maxPhases or violate the consistency checks defined in Section 4.3.2. 1.3.6.1.4.1.1206.4.2.1.6.2.1.20 P2" DEFVAL { "" } ::= { preemptEntry 20 } preemptCyclingOverlap OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION " Each octet within the octet string contains a overlapNumber (binary value) that is allowed to cycle during the Preempt Dwell interval. The values of overlapNumber used here shall not exceed maxOverlaps or violate the consistency checks defined in Section 4.3.2. 1.3.6.1.4.1.1206.4.2.1.6.2.1.21 P2" DEFVAL { "" } ::= { preemptEntry 21 } preemptEnterYellowChange OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Enter Yellow Change in tenth seconds (0-25.5 sec). This parameter controls the yellow change timing for a normal Yellow Change signal terminated by a preempt initiated transition. A preempt initiated transition shall not cause the termination of a Yellow Change prior to its display for the lesser of the phase's Yellow Change time or this period. CAUTION - if this value is zero, phase Yellow Change is terminated immediately. 1.3.6.1.4.1.1206.4.2.1.6.2.1.22 P tenth second" DEFVAL { 255 } ::= { preemptEntry 22 } preemptEnterRedClear OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Enter Red Clear in tenth seconds (0-25.5 sec). This parameter controls the red clearance timing for a normal Red Clear signal terminated by a preempt initiated transition. A preempt initiated transition shall not cause the termination of a Red Clear prior to its display for the lesser of the phase's Red Clear time or this period. CAUTION - if this value is zero, phase Red Clear is terminated immediately. 1.3.6.1.4.1.1206.4.2.1.6.2.1.23 P tenth second" DEFVAL { 255 } ::= { preemptEntry 23 } preemptTrackYellowChange OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Track Clear Yellow Change time in tenth seconds (0-25.5 sec). The lesser of the phase's Yellow Change time or this parameter controls the yellow timing for the track clearance movement. Track clear phase(s) are enabled in the preemptTrackPhase object. 1.3.6.1.4.1.1206.4.2.1.6.2.1.24 P tenth second" DEFVAL { 255 } ::= { preemptEntry 24 } preemptTrackRedClear OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Track Clear Red Clear time in tenth seconds (0-25.5 sec). The lesser of the phase's Red Clear time or this parameter controls the Red Clear timing for the track clearance movement. Track clear phase(s) are enabled in the preemptTrackPhase object. 1.3.6.1.4.1.1206.4.2.1.6.2.1.25 P tenth second" DEFVAL { 255 } ::= { preemptEntry 25 } preemptSequenceNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION " This object is used to configure the sequenceNumber to run during the preempt's dwell duration. This value shall not exceed the maxSequences object value. 1.3.6.1.4.1.1206.4.2.1.6.2.1.26 P sequence" ::= { preemptEntry 26 } preemptExitType OBJECT-TYPE SYNTAX INTEGER { exitPhases (1), queueDelayRecovery (2), shortService (3), exitCoord (4)} ACCESS read-write STATUS mandatory DESCRIPTION " This object defines the exit strategy (type) to be used following the end of the preempt. The exit types are as follows: exitPhases: the CU immediately enters the exit phases to be active as configured queueDelayRecovery: the CU immediately enters the phase with the highest demand or longest wait time shortService: the CU immediately enters the first short service phase. The first short service phase is a phase where only the preempt minimum green time was serviced during the advanced preemption time or the right-of-way transfer time exitCoord: the CU immediately returns to the place in the coordinated cycle where the ASC would have been if there was no preempt P 1.3.6.1.4.1.1206.4.2.1.6.2.1.27" ::= { preemptEntry 28 } preemptControlTable OBJECT-TYPE SYNTAX SEQUENCE OF PreemptControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " This table contains the control objects that allow the preempts to be activated remotely. There shall be one control object for each preempt input supported by the device. The number of rows in this table shall be equal to maxPreempts. static 1.3.6.1.4.1.1206.4.2.1.6.3" ::= { preempt 3 } preemptControlEntry OBJECT-TYPE SYNTAX PreemptControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Control objects for each preempt input. These objects allow the system to activate preempt functions remotely. 1.3.6.1.4.1.1206.4.2.1.6.3.1" INDEX { preemptControlNumber } ::= { preemptControlTable 1 } PreemptControlEntry ::= SEQUENCE { preemptControlNumber INTEGER, preemptControlState INTEGER } preemptControlNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " This object shall indicate the preempt input number controlled by the associated preemptControlState object in this row. 1.3.6.1.4.1.1206.4.2.1.6.3.1.1 S preempt" ::= { preemptControlEntry 1 } preemptControlState OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-write STATUS mandatory DESCRIPTION " This object when set to ON (one) shall cause the associated preempt actions to occur unless the actions have already been started by the physical preempt input. The preempt shall remain active as long as this object is ON or the physical preempt input is ON. This object when set to OFF (zero) shall cause the physical preempt input to control the associated preempt actions. The device shall reset this object to ZERO when in BACKUP Mode. A write to this object shall reset the Backup timer to ZERO (see unitBackupTime). 1.3.6.1.4.1.1206.4.2.1.6.3.1.2 C" ::= { preemptControlEntry 2 } preemptStatus OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " This object defines the preempt number that is currently being serviced in the device. 1.3.6.1.4.1.1206.4.2.1.6.4" ::= { preempt 4 } maxPreemptGroups OBJECT-TYPE SYNTAX INTEGER (0..2) ACCESS read-only STATUS mandatory DESCRIPTION " The Maximum Number of Preempt Groups (8 Preempt per group) this CU supports. This value is equal to TRUNCATE [(maxPreempts + 7) / 8]. This object indicates the maximum rows which shall appear in the preemptStatusGroupTable. 1.3.6.1.4.1.1206.4.2.1.6.5 S group" ::= { preempt 5 } preemptStatusGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF PreemptStatusGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table containing the CU preempt input signal status in groups of eight Preempts. The number of rows in this table is equal to the maxPreemptGroups object. static 1.3.6.1.4.1.1206.4.2.1.6.6" ::= { preempt 6 } preemptStatusGroupEntry OBJECT-TYPE SYNTAX PreemptStatusGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Preempt input signal status for eight preempt inputs. 1.3.6.1.4.1.1206.4.2.1.6.6.1" INDEX { preemptStatusGroupNumber } ::= { preemptStatusGroupTable 1 } PreemptStatusGroupEntry ::= SEQUENCE { preemptStatusGroupNumber INTEGER, preemptStatusGroup INTEGER } preemptStatusGroupNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The Preempt StatusGroup number for objects in this row. This value shall not exceed the maxPreemptGroups object value. 1.3.6.1.4.1.1206.4.2.1.6.6.1.1 S group" ::= { preemptStatusGroupEntry 1 } preemptStatusGroup OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " Preempt Input Signal Status Mask. When a bit = 1, a preempt input signal is detected or the preemptControlState is ON for that input, and when a bit = 0, no preempt input signal is detected and the preemptControlState is OFF for that input. Bit 7: Preempt # = (preemptStatusGroupNumber * 8) Bit 6: Preempt # = (preemptStatusGroupNumber * 8) - 1 Bit 5: Preempt # = (preemptStatusGroupNumber * 8) - 2 Bit 4: Preempt # = (preemptStatusGroupNumber * 8) - 3 Bit 3: Preempt # = (preemptStatusGroupNumber * 8) - 4 Bit 2: Preempt # = (preemptStatusGroupNumber * 8) - 5 Bit 1: Preempt # = (preemptStatusGroupNumber * 8) - 6 Bit 0: Preempt # = (preemptStatusGroupNumber * 8) - 7 1.3.6.1.4.1.1206.4.2.1.6.6.1.2 S" ::= { preemptStatusGroupEntry 2 } preemptQueueDelayTable OBJECT-TYPE SYNTAX SEQUENCE OF PreemptQueueDelayEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table containing CU detector parameters for the queue delay recovery exit strategy. The number of rows in this table will not exceed the maxVehicleDetectors object. static 1.3.6.1.4.1.1206.4.2.1.6.7" ::={ preempt 7 } preemptQueueDelayEntry OBJECT-TYPE SYNTAX PreemptQueueDelayEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Parameters for a specific CU preempt input if the queue delay recovery exit strategy is used. 1.3.6.1.4.1.1206.4.2.1.6.7.1" INDEX { preemptNumber, vehicleDetectorNumber } ::={ preemptQueueDelayTable 1} PreemptQueueDelayEntry ::= SEQUENCE { preemptDetectorWeight INTEGER } preemptDetectorWeight OBJECT-TYPE SYNTAX INTEGER (0..1000) ACCESS read-write STATUS mandatory DESCRIPTION " This object defines the relative weight for the associated detector when using the detector data to determine the queue delay recovery exit strategy from a preempt input. The association between the vehicleDetectorNumber and a phase is identified by the vehicleDetectorCallPhase. 1.3.6.1.4.1.1206.4.2.1.6.7.1.1 P" ::= { preemptQueueDelayEntry 1 } maxPreemptGates OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The maximum number of preempt gates this CU supports. This object indicates the maximum rows which shall appear in the preemptGateTable. 1.3.6.1.4.1.1206.4.2.1.6.8 S gates" ::= { preempt 8 } preemptGateTable OBJECT-TYPE SYNTAX SEQUENCE OF PreemptGateEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table containing the status of the gates that may be lowered during a preempt sequence. static 1.3.6.1.4.1.1206.4.2.1.6.9" ::= { preempt 9 } preemptGateEntry OBJECT-TYPE SYNTAX PreemptGateEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Gate status for preempt sequences. 1.3.6.1.4.1.1206.4.2.1.6.9.1" INDEX { preemptGateNumber } ::= { preemptGateTable 1 } PreemptGateEntry ::= SEQUENCE { preemptGateNumber INTEGER, preemptGateStatus INTEGER, preemptGateDescription DisplayString } preemptGateNumber OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-only STATUS mandatory DESCRIPTION " The Preempt Gate number for objects in this row. 1.3.6.1.4.1.1206.4.2.1.6.9.1.1 S" ::= { preemptGateEntry 1 } preemptGateStatus OBJECT-TYPE SYNTAX INTEGER { unknown(1), other(2), up(3), down(4) } ACCESS read-only STATUS mandatory DESCRIPTION " The status of a gate that may be lowered during a preempt sequence. unknown: The status of unknown or no gate is present other: The gate is neither in the locked up or locked down position up: The gate is in an up position down: The gate is in a down position 1.3.6.1.4.1.1206.4.2.1.6.9.1.2 S" DEFVAL { unknown } ::= { preemptGateEntry 2 } preemptGateDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-write STATUS mandatory DESCRIPTION " A textual string indicating the location and perhaps type of gate. 1.3.6.1.4.1.1206.4.2.1.6.9.1.3 P" ::= { preemptGateEntry 3 } ring OBJECT IDENTIFIER ::= { asc 7 } -- The ring node contains objects that support ring configuration, -- status and control functions in the device. maxRings OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The value of this object shall specify the maximum number of rings this device supports. 1.3.6.1.4.1.1206.4.2.1.7.1 S ring" ::= { ring 1 } maxSequences OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The value of this object shall specify the maximum number of sequence plans this device supports. 1.3.6.1.4.1.1206.4.2.1.7.2 S sequence" ::= { ring 2 } sequenceTable OBJECT-TYPE SYNTAX SEQUENCE OF SequenceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " This table contains all the sequence plans for the controller. A sequence plan shall consist of one row for each ring that the CU supports. Each row defines the phase service order for that ring. static 1.3.6.1.4.1.1206.4.2.1.7.3" ::= { ring 3 } sequenceEntry OBJECT-TYPE SYNTAX SequenceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Phase Sequence Parameters for an Actuated Controller Unit. 1.3.6.1.4.1.1206.4.2.1.7.3.1" INDEX { sequenceNumber, sequenceRingNumber } ::= { sequenceTable 1 } SequenceEntry ::= SEQUENCE { sequenceNumber INTEGER, sequenceRingNumber INTEGER, sequenceData OCTET STRING } sequenceNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " This number identifies a sequence plan. Each row of the table contains the phase sequence for a ring. A sequence plan shall consist of one row for each ring that defines the phase sequences for that ring. 1.3.6.1.4.1.1206.4.2.1.7.3.1.1 S sequence" ::= { sequenceEntry 1 } sequenceRingNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " This number identifies the ring number this phase sequence applies to. 1.3.6.1.4.1.1206.4.2.1.7.3.1.2 S ring" ::= { sequenceEntry 2 } sequenceData OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION " Each octet is a Phase Number (binary value) within the associated ring number. The phase number value shall not exceed the maxPhases object value. The order of phase numbers determines the phase sequence for the ring. The phase numbers shall not be ordered in a manner that would violate the Consistency Checks defined in Section 4.3.2. 1.3.6.1.4.1.1206.4.2.1.7.3.1.3 P2" ::= { sequenceEntry 3 } maxRingControlGroups OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The maximum number of Ring Control Groups (8 rings per group) this Actuated Controller Unit supports. This value is equal to TRUNCATE[(maxRings + 7) / 8]. This object indicates the maximum rows which shall appear in the ringControlGroupTable object. 1.3.6.1.4.1.1206.4.2.1.7.4 S group" ::= { ring 4 } ringControlGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF RingControlGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table containing Actuated Controller Unit Ring Control in groups of eight rings. The number of rows in this table is equal to the maxRingControlGroups object. static < 1.3.6.1.4.1.1206.4.2.1.7.5" ::= { ring 5 } ringControlGroupEntry OBJECT-TYPE SYNTAX RingControlGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Ring Control for eight Actuated Controller Unit rings. 1.3.6.1.4.1.1206.4.2.1.7.5.1" INDEX { ringControlGroupNumber } ::= { ringControlGroupTable 1 } RingControlGroupEntry ::= SEQUENCE { ringControlGroupNumber INTEGER, ringControlGroupStopTime INTEGER, ringControlGroupForceOff INTEGER, ringControlGroupMax2 INTEGER, ringControlGroupMaxInhibit INTEGER, ringControlGroupPedRecycle INTEGER, ringControlGroupRedRest INTEGER, ringControlGroupOmitRedClear INTEGER, ringControlGroupMax3 INTEGER } ringControlGroupNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The Ring Control Group number for objects in this row. This value shall not exceed the maxRingControlGroups object value. 1.3.6.1.4.1.1206.4.2.1.7.5.1.1 S group" ::= { ringControlGroupEntry 1 } ringControlGroupStopTime OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " This object is used to allow a remote entity to stop timing in the device. The device shall activate/deactivate the System Stop Time control for a ring according to the respective bit value as follows: bit = 0 - deactivate the ring control bit = 1 - activate the ring control Bit 7: Ring # = (ringControlGroupNumber * 8) Bit 6: Ring # = (ringControlGroupNumber * 8) - 1 Bit 5: Ring # = (ringControlGroupNumber * 8) - 2 Bit 4: Ring # = (ringControlGroupNumber * 8) - 3 Bit 3: Ring # = (ringControlGroupNumber * 8) - 4 Bit 2: Ring # = (ringControlGroupNumber * 8) - 5 Bit 1: Ring # = (ringControlGroupNumber * 8) - 6 Bit 0: Ring # = (ringControlGroupNumber * 8) - 7 The device shall reset this object to ZERO when in BACKUP Mode. A write to this object shall reset the Backup timer to ZERO (see unitBackupTime). 1.3.6.1.4.1.1206.4.2.1.7.5.1.2 C" REFERENCE "NEMA TS 2 Clause 3.5.4.1.6" ::= { ringControlGroupEntry 2 } ringControlGroupForceOff OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " This object is used to allow a remote entity to terminate phases via a force off command in the device. The device shall activate/deactivate the System Force Off control for a ring according to the respective bit value as follows: bit = 0 - deactivate the ring control bit = 1 - activate the ring control Bit 7: Ring # = (ringControlGroupNumber * 8) Bit 6: Ring # = (ringControlGroupNumber * 8) - 1 Bit 5: Ring # = (ringControlGroupNumber * 8) - 2 Bit 4: Ring # = (ringControlGroupNumber * 8) - 3 Bit 3: Ring # = (ringControlGroupNumber * 8) - 4 Bit 2: Ring # = (ringControlGroupNumber * 8) - 5 Bit 1: Ring # = (ringControlGroupNumber * 8) - 6 Bit 0: Ring # = (ringControlGroupNumber * 8) - 7 The device shall reset this object to ZERO when in BACKUP Mode. A write to this object shall reset the Backup timer to ZERO (see unitBackupTime). 1.3.6.1.4.1.1206.4.2.1.7.5.1.3 C" REFERENCE "NEMA TS 2 Clause 3.5.4.1.1" ::= { ringControlGroupEntry 3 } ringControlGroupMax2 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " This object is used to allow a remote entity to request Maximum 2 timings in the device. The device shall activate/deactivate the System Maximum 2 control for a ring according to the respective bit value as follows: bit = 0 - deactivate the ring control bit = 1 - activate the ring control Bit 7: Ring # = (ringControlGroupNumber * 8) Bit 6: Ring # = (ringControlGroupNumber * 8) - 1 Bit 5: Ring # = (ringControlGroupNumber * 8) - 2 Bit 4: Ring # = (ringControlGroupNumber * 8) - 3 Bit 3: Ring # = (ringControlGroupNumber * 8) - 4 Bit 2: Ring # = (ringControlGroupNumber * 8) - 5 Bit 1: Ring # = (ringControlGroupNumber * 8) - 6 Bit 0: Ring # = (ringControlGroupNumber * 8) - 7 The device shall reset this object to ZERO when in BACKUP Mode. A write to this object shall reset the Backup timer to ZERO (see unitBackupTime). 1.3.6.1.4.1.1206.4.2.1.7.5.1.4 C" REFERENCE "NEMA TS 2 Clause 3.5.4.1.7" ::= { ringControlGroupEntry 4 } ringControlGroupMaxInhibit OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " This object is used to allow a remote entity to request internal maximum timings be inhibited in the device. The device shall activate/deactivate the System Max Inhibit control for a ring according to the respective bit value as follows: bit = 0 - deactivate the ring control bit = 1 - activate the ring control Bit 7: Ring # = (ringControlGroupNumber * 8) Bit 6: Ring # = (ringControlGroupNumber * 8) - 1 Bit 5: Ring # = (ringControlGroupNumber * 8) - 2 Bit 4: Ring # = (ringControlGroupNumber * 8) - 3 Bit 3: Ring # = (ringControlGroupNumber * 8) - 4 Bit 2: Ring # = (ringControlGroupNumber * 8) - 5 Bit 1: Ring # = (ringControlGroupNumber * 8) - 6 Bit 0: Ring # = (ringControlGroupNumber * 8) - 7 The device shall reset this object to ZERO when in BACKUP Mode. A write to this object shall reset the Backup timer to ZERO (see unitBackupTime). 1.3.6.1.4.1.1206.4.2.1.7.5.1.5 C" REFERENCE "NEMA TS 2 Clause 3.5.4.1.3" ::= { ringControlGroupEntry 5 } ringControlGroupPedRecycle OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " This object is used to allow a remote entity to request a pedestrian recycle in the device. The device shall activate/deactivate the System Ped Recycle control for a ring according to the respective bit value as follows: bit = 0 - deactivate the ring control bit = 1 - activate the ring control Bit 7: Ring # = (ringControlGroupNumber * 8) Bit 6: Ring # = (ringControlGroupNumber * 8) - 1 Bit 5: Ring # = (ringControlGroupNumber * 8) - 2 Bit 4: Ring # = (ringControlGroupNumber * 8) - 3 Bit 3: Ring # = (ringControlGroupNumber * 8) - 4 Bit 2: Ring # = (ringControlGroupNumber * 8) - 5 Bit 1: Ring # = (ringControlGroupNumber * 8) - 6 Bit 0: Ring # = (ringControlGroupNumber * 8) - 7 The device shall reset this object to ZERO when in BACKUP Mode. A write to this object shall reset the Backup timer to ZERO (see unitBackupTime). 1.3.6.1.4.1.1206.4.2.1.7.5.1.6 C" REFERENCE "NEMA TS 2 Clause 3.5.4.1.5" ::= { ringControlGroupEntry 6 } ringControlGroupRedRest OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " This object is used to allow a remote entity to request red rest in the device. The device shall activate/deactivate the System Red Rest control for a ring according to the respective bit value as follows: bit = 0 - deactivate the ring control bit = 1 - activate the ring control Bit 7: Ring # = (ringControlGroupNumber * 8) Bit 6: Ring # = (ringControlGroupNumber * 8) - 1 Bit 5: Ring # = (ringControlGroupNumber * 8) - 2 Bit 4: Ring # = (ringControlGroupNumber * 8) - 3 Bit 3: Ring # = (ringControlGroupNumber * 8) - 4 Bit 2: Ring # = (ringControlGroupNumber * 8) - 5 Bit 1: Ring # = (ringControlGroupNumber * 8) - 6 Bit 0: Ring # = (ringControlGroupNumber * 8) - 7 The device shall reset this object to ZERO when in BACKUP Mode. A write to this object shall reset the Backup timer to ZERO (see unitBackupTime). 1.3.6.1.4.1.1206.4.2.1.7.5.1.7 C" REFERENCE "NEMA TS 2 Clause 3.5.4.1.2" ::= { ringControlGroupEntry 7 } ringControlGroupOmitRedClear OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " This object is used to allow a remote entity to omit red clearances in the device. The device shall activate/deactivate the System Omit Red Clear control for a ring according to the respective bit value as follows: bit = 0 - deactivate the ring control bit = 1 - activate the ring control Bit 7: Ring # = (ringControlGroupNumber * 8) Bit 6: Ring # = (ringControlGroupNumber * 8) - 1 Bit 5: Ring # = (ringControlGroupNumber * 8) - 2 Bit 4: Ring # = (ringControlGroupNumber * 8) - 3 Bit 3: Ring # = (ringControlGroupNumber * 8) - 4 Bit 2: Ring # = (ringControlGroupNumber * 8) - 5 Bit 1: Ring # = (ringControlGroupNumber * 8) - 6 Bit 0: Ring # = (ringControlGroupNumber * 8) - 7 The device shall reset this object to ZERO when in BACKUP Mode. A write to this object shall reset the Backup timer to ZERO (see unitBackupTime). 1.3.6.1.4.1.1206.4.2.1.7.5.1.8 C" REFERENCE "NEMA TS 2 Clause 3.5.4.1.4" ::= { ringControlGroupEntry 8 } ringControlGroupMax3 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " This object is used to allow a remote entity to request Maximum 3 timings in the device. The device shall activate/deactivate the System Maximum 3 control for a ring according to the respective bit value as follows: bit = 0 - deactivate the ring control bit = 1 - activate the ring control Bit 7: Ring # = (ringControlGroupNumber * 8) Bit 6: Ring # = (ringControlGroupNumber * 8) - 1 Bit 5: Ring # = (ringControlGroupNumber * 8) - 2 Bit 4: Ring # = (ringControlGroupNumber * 8) - 3 Bit 3: Ring # = (ringControlGroupNumber * 8) - 4 Bit 2: Ring # = (ringControlGroupNumber * 8) - 5 Bit 1: Ring # = (ringControlGroupNumber * 8) - 6 Bit 0: Ring # = (ringControlGroupNumber * 8) - 7 The device shall reset this object to ZERO when in BACKUP Mode. A write to this object shall reset the Backup timer to ZERO (see unitBackupTime). 1.3.6.1.4.1.1206.4.2.1.7.5.1.9 C" ::= { ringControlGroupEntry 9 } ringStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF RingStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table containing Actuated Controller Unit Ring Status. The number of rows in this table is equal to the maxRings object. static 1.3.6.1.4.1.1206.4.2.1.7.6" ::= { ring 6 } ringStatusEntry OBJECT-TYPE SYNTAX RingStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Ring Status for an Actuated Controller Unit ring. 1.3.6.1.4.1.1206.4.2.1.7.6.1" INDEX { sequenceRingNumber } ::= { ringStatusTable 1 } RingStatusEntry ::= SEQUENCE { ringStatus INTEGER } ringStatus OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " The Ring Status for this ring. Bit 7: Reserved (always zero) Bit 6: Reserved (always zero) Bit 5: Force Off - When bit = 1, the active phase in the ring was terminated by Force Off Bit 4: Max Out - When bit = 1, the active phase in the ring was terminated by Max Out Bit 3: Gap Out - When bit = 1, the active phase in the ring was terminated by Gap Out Bit 2: Coded Status Bit C Bit 1: Coded Status Bit B Bit 0: Coded Status Bit A +======+=====+=====+=====+===============+ | Code | Bit States | State | | ## | A | B | C | Names | +======+=====+=====+=====+===============+ | 0 | 0 | 0 | 0 | Min Green | | 1 | 1 | 0 | 0 | Extension | | 2 | 0 | 1 | 0 | Maximum | | 3 | 1 | 1 | 0 | Green Rest | | 4 | 0 | 0 | 1 | Yellow Change | | 5 | 1 | 0 | 1 | Red Clearance | | 6 | 0 | 1 | 1 | Red Rest | | 7 | 1 | 1 | 1 | Undefined | +======+=====+=====+=====+===============+ NEMA TS 2 Clause 3.5.4.2 provides further definition of Coded Status Bits. 1.3.6.1.4.1.1206.4.2.1.7.6.1.1 S" ::= { ringStatusEntry 1 } channel OBJECT IDENTIFIER ::= { asc 8 } --This defines a node for supporting channel objects. maxChannels OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The Maximum Number of Channels this Actuated Controller Unit supports. This object indicates the maximum rows which shall appear in the channelTable object. 1.3.6.1.4.1.1206.4.2.1.8.1 S channel" ::= { channel 1 } channelTable OBJECT-TYPE SYNTAX SEQUENCE OF ChannelEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table containing Actuated Controller Unit channel parameters. The number of rows in this table is equal to the maxChannels object. static 1.3.6.1.4.1.1206.4.2.1.8.2" ::= { channel 2 } channelEntry OBJECT-TYPE SYNTAX ChannelEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Parameters for a specific Actuated Controller Unit channel. 1.3.6.1.4.1.1206.4.2.1.8.2.1" INDEX { channelNumber } ::= { channelTable 1 } ChannelEntry ::= SEQUENCE { channelNumber INTEGER, channelControlSource INTEGER, channelControlType INTEGER, channelFlash INTEGER, channelDim INTEGER, channelGreenType INTEGER, channelGreenIncluded OCTET STRING, channelIntersectionId INTEGER } channelNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The channel number for objects in this row. This value shall not exceed the maxChannels object value. 1.3.6.1.4.1.1206.4.2.1.8.2.1.1 S channel" ::= { channelEntry 1 } channelControlSource OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " This object defines the channel control source (which Phase or Overlap). The value shall not exceed maxPhases or maxOverlaps as determined by channelControlType object: Value 00 = No Control (Not In Use) Value 01 = Phase 01 or Overlap A Value 02 = Phase 02 or Overlap B || Value 15 = Phase 15 or Overlap O Value 16 = Phase 16 or Overlap P etc. 1.3.6.1.4.1.1206.4.2.1.8.2.1.2 P" ::= { channelEntry 2 } channelControlType OBJECT-TYPE SYNTAX INTEGER { other (1), phaseVehicle (2), phasePedestrian (3), overlap (4), pedOverlap (5), queueJump (6) } ACCESS read-write STATUS mandatory DESCRIPTION " This object defines the channel control type (Vehicle Phase, Pedestrian Phase, or Overlap): other: The channel controls an other type of display. phaseVehicle: The channel controls a vehicle phase display. Also valid for bicycle phases and transit phases. phasePedestrian: The channel controls a pedestrian phase display. overlap: The channel controls an overlap display, which might include flashing yellow arrows, flashing red arrows, vehicle overlaps, bicycle overlaps and transit overlaps. pedOverlap: The channel controls an overlap for pedestrian display. queueJump: The channel controls a queue jump display typically used for transit priority 1.3.6.1.4.1.1206.4.2.1.8.2.1.3 P" ::= { channelEntry 3 } channelFlash OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " This object defines the channel state during Automatic Flash. Bit 7: Reserved Bit 6: Reserved Bit 5: Reserved Bit 4: Reserved Bit 3: Flash Alternate Half Hertz Bit=0: Off/Disabled & Bit=1: On/Enabled Bit 2: Flash Red Bit=0: Off/Red Dark & Bit=1: On/Flash Red Bit 1: Flash Yellow Bit=0: Off/Yellow Dark & Bit=1: On/Flash Yellow Bit 0: Reserved A SET of both bits 1 & 2 shall result in bit 1=0 and bit 2=1. A SET of a 'reserved' bit to a value other than zero (0) shall return a badValue(3) error. 1.3.6.1.4.1.1206.4.2.1.8.2.1.4 P" ::= { channelEntry 4 } channelDim OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " This object defines the channel state during Dimming. Dimming shall be accomplished by the elimination of alternate one-half segments from the AC sinusoid applied to the field terminals. Bit 7: Reserved Bit 6: Reserved Bit 5: Reserved Bit 4: Reserved Bit 3: Dim Alternate Half Line Cycle Bit=0: Off/+ half cycle & Bit=1: On/- half cycle Bit 2: Dim Red Bit=0: Off/Red Not Dimmed & Bit=1: On/Dimmed Red Bit 1: Dim Yellow Bit=0: Off / Yellow Not Dimmed & Bit=1: On / Dimmed Yellow Bit 0: Dim Green Bit=0: Off / Green Not Dimmed & Bit=1: On / Dimmed Green A SET of a 'reserved' bit to a value other than zero (0) shall return a badValue(3) error. 1.3.6.1.4.1.1206.4.2.1.8.2.1.5 P" ::= { channelEntry 5 } channelGreenType OBJECT-TYPE SYNTAX INTEGER { other (1), protected (2), permissive (3), flashYellow (4), flashRed (5) } ACCESS read-write STATUS deprecated DESCRIPTION " This object defines the signalState for this channel when the channel output is Green. This object is used to support the generation of SPaT data. other: the allowed movement controlled by this channel is not defined by this standard. protected: indicates that at least a portion of the green movement occurs in protected mode. permissive: indicates that the green movement occurs in permissive mode, that is, any turns are permitted to be made only after yielding to pedestrians and/or any opposing traffic. flashYellow: indicates that a vehicle may proceed but with caution after yielding to pedestrians and/or any conflicting traffic. Includes flashing yellow arrows. flashRed: indicates that a vehicle may proceed after stopping and yielding to pedestrians and/or any conflicting traffic. Includes flashing red arrows. Note that there is a similar object called movementManeuverGreenType. 1.3.6.1.4.1.1206.4.2.1.8.2.1.6 P" ::= { channelEntry 6 } channelGreenIncluded OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS deprecated DESCRIPTION " If the channelGreenType for this channel is 'protected (2)', this object is used to indicate if and when this movement is in permissive mode. This object is used to support the generation of SPaT data and defines the signalState (See signalState) for the movements associated with this channel only IF the channelGreenType for this channel is 'protected (2)'. Each octet in the octet string represents a conflicting or opposing channelNumber, which if the status for any octet in the octet string is NOT Channel Red or is Dark, then the signalState for the movement is 'permissive-Movement-Allowed (5)' when the status for this channel is channel Green. Otherwise, the signalState for the movement is 'protected-Movement-Allowed (6)' when the status for this channel is channel Green. If channelGreenType in this row is not 'protected (2)', then this object value is ignored. It is assumed that a clearance state following a signalState of 'permissive movement allowed' will be a signalState of 'permissive clearance', and a clearance state following a signalState of 'protected movement allowed' will be a signalState of 'protected movement allowed'. For example, assume channelNumber 1 represents a northbound left turn, while channelNumber 2 is a southbound through movement. A channelGreenType.1 of 'protected (2)' and channelGreenIncluded.1 of '02' indicates that if the status of channelNumber 2 is NOT Channel Red or is dark, then signalState for the movement associated with channelNumber.1 is 'permissive-Movement-Allowed (5)' when the status for channelNumber.1 is channel Green. Otherwise, the signalState for the movement associated with channelNumber.1 is 'protected-Movement-Allowed (6)' when the status for this channel is channel Green. 1.3.6.1.4.1.1206.4.2.1.8.2.1.7 P" ::= { channelEntry 7 } channelIntersectionId OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS deprecated DESCRIPTION " To support SAE J2735, this object is used to support the exchange of SPaT data and contains the (regionally) unique identifier of the intersection that the channel output is associated with. It is expected that this same identifier will be broadcasted in a MAP data message that describes the roadway geometry configuration of this intersection. 1.3.6.1.4.1.1206.4.2.1.8.2.1.8 P" REFERENCE "SAE J2735 DE_IntersectionID" ::= { channelEntry 8 } maxChannelStatusGroups OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The maximum number of Channel Status Groups (8 channels per group) this Actuated Controller Unit supports. This value is equal to TRUNCATE [(maxChannels + 7) / 8]. This object indicates the maximum rows which shall appear in the channelStatusGroupTable object. 1.3.6.1.4.1.1206.4.2.1.8.3 S group" ::= { channel 3 } channelStatusGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF ChannelStatusGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table containing Actuated Controller Unit channel output (Red, Yellow, & Green) status in groups of eight channels. The number of rows in this table is equal to the maxChannelStatusGroups object. static 1.3.6.1.4.1.1206.4.2.1.8.4" ::= { channel 4 } channelStatusGroupEntry OBJECT-TYPE SYNTAX ChannelStatusGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Red, Yellow, & Green Output Status for eight Actuated Controller Unit channels. 1.3.6.1.4.1.1206.4.2.1.8.4.1" INDEX { channelStatusGroupNumber } ::= { channelStatusGroupTable 1 } ChannelStatusGroupEntry ::= SEQUENCE { channelStatusGroupNumber INTEGER, channelStatusGroupReds INTEGER, channelStatusGroupYellows INTEGER, channelStatusGroupGreens INTEGER } channelStatusGroupNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The channelStatusGroup number for objects in this row. This value shall not exceed the maxChannelStatusGroups object value. 1.3.6.1.4.1.1206.4.2.1.8.4.1.1 S group" ::= { channelStatusGroupEntry 1 } channelStatusGroupReds OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " Channel Red Output Status Mask, when a bit=1, the Channel Red is currently active. When a bit=0, the Channel Red is NOT currently active. Bit 7: Channel # = (channelStatusGroupNumber * 8) Bit 6: Channel # = (channelStatusGroupNumber * 8) - 1 Bit 5: Channel # = (channelStatusGroupNumber * 8) - 2 Bit 4: Channel # = (channelStatusGroupNumber * 8) - 3 Bit 3: Channel # = (channelStatusGroupNumber * 8) - 4 Bit 2: Channel # = (channelStatusGroupNumber * 8) - 5 Bit 1: Channel # = (channelStatusGroupNumber * 8) - 6 Bit 0: Channel # = (channelStatusGroupNumber * 8) - 7 1.3.6.1.4.1.1206.4.2.1.8.4.1.2 S" ::= { channelStatusGroupEntry 2 } channelStatusGroupYellows OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " Channel Yellow Output Status Mask, when a bit=1, the Channel Yellow is currently active. When a bit=0, the Channel Yellow is NOT currently active. Bit 7: Channel # = (channelStatusGroupNumber * 8) Bit 6: Channel # = (channelStatusGroupNumber * 8) - 1 Bit 5: Channel # = (channelStatusGroupNumber * 8) - 2 Bit 4: Channel # = (channelStatusGroupNumber * 8) - 3 Bit 3: Channel # = (channelStatusGroupNumber * 8) - 4 Bit 2: Channel # = (channelStatusGroupNumber * 8) - 5 Bit 1: Channel # = (channelStatusGroupNumber * 8) - 6 Bit 0: Channel # = (channelStatusGroupNumber * 8) - 7 1.3.6.1.4.1.1206.4.2.1.8.4.1.3 S" ::= { channelStatusGroupEntry 3 } channelStatusGroupGreens OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " Channel Green Output Status Mask, when a bit=1, the Channel Green is currently active. When a bit=0, the Channel Green is NOT currently active. Bit 7: Channel # = (channelStatusGroupNumber * 8) Bit 6: Channel # = (channelStatusGroupNumber * 8) - 1 Bit 5: Channel # = (channelStatusGroupNumber * 8) - 2 Bit 4: Channel # = (channelStatusGroupNumber * 8) - 3 Bit 3: Channel # = (channelStatusGroupNumber * 8) - 4 Bit 2: Channel # = (channelStatusGroupNumber * 8) - 5 Bit 1: Channel # = (channelStatusGroupNumber * 8) - 6 Bit 0: Channel # = (channelStatusGroupNumber * 8) - 7 1.3.6.1.4.1.1206.4.2.1.8.4.1.4 S" ::= { channelStatusGroupEntry 4 } overlap OBJECT IDENTIFIER ::= { asc 9 } -- This node contains objects that configure, monitor and -- control overlap functions. maxOverlaps OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The Maximum Number of Overlaps this Actuated Controller Unit supports. This object indicates the maximum number of rows which shall appear in the overlapTable object. 1.3.6.1.4.1.1206.4.2.1.9.1 S overlap" ::= { overlap 1 } overlapTable OBJECT-TYPE SYNTAX SEQUENCE OF OverlapEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table containing Actuated Controller Unit overlap parameters. The number of rows in this table is equal to the maxOverlaps object. static 1.3.6.1.4.1.1206.4.2.1.9.2" ::= { overlap 2 } overlapEntry OBJECT-TYPE SYNTAX OverlapEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Parameters for a specific Actuated Controller Unit overlap. 1.3.6.1.4.1.1206.4.2.1.9.2.1" INDEX { overlapNumber } ::= { overlapTable 1 } OverlapEntry ::= SEQUENCE { overlapNumber INTEGER, overlapType INTEGER, overlapIncludedPhases OCTET STRING, overlapModifierPhases OCTET STRING, overlapTrailGreen INTEGER, overlapTrailYellow INTEGER, overlapTrailRed INTEGER, overlapWalk INTEGER, overlapPedClearance INTEGER, overlapConflictingPedPhases OCTET STRING } overlapNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The overlap number for objects in this row. The value shall not exceed the maxOverlaps object. The value maps to the Overlap as follows: 1 = Overlap A, 2 = Overlap B etc. 1.3.6.1.4.1.1206.4.2.1.9.2.1.1 S overlap" ::= { overlapEntry 1 } overlapType OBJECT-TYPE SYNTAX INTEGER { other(1), normal (2), minusGreenYellow (3), pedestrianNormal (4), fYAThreeSection (5), fYAFourSection (6), fRAThreeSection (7), fRAFourSection (8), transit-2 (9), minusGreenYellowAlternate (10)} ACCESS read-write STATUS mandatory DESCRIPTION " The type of overlap operation for this row. The types are as follows: other: The overlap operates in another mode than those described herein. normal: The overlap output shall be controlled by the overlapIncludedPhases when this type is indicated. The overlap output shall be green in the following situations: (1) when an overlap included phase is green. (2) when an overlap included phase is yellow (or red clearance) and an overlap included phase is next. The overlap output shall be yellow when an included phase is yellow and an overlap included phase is not next. The overlap output shall be red whenever the overlap green and yellow are not ON. minusGreenYellow: The overlap output shall be controlled by the overlapIncludedPhases and the overlapModifierPhases if this type is indicated. The overlap output shall be green in the following situations: (1) when an overlap included phase is green and an overlap modifier phase is NOT green. (2) when an overlap included phase is yellow (or red clearance) and an overlap included phase is next and an overlap modifier phase is NOT green. The overlap output shall be yellow when an overlap included phase is yellow and an overlap modifier phase is NOT yellow and an overlap included phase is not next. The overlap output shall be red whenever the overlap green and yellow are not ON. pedestrianNormal: The overlap output shall be controlled by the overlapIncludedPhases when this type is indicated. The overlap output shall be Walk in the following situations: (1) when an overlap included phase is green. (2) when an overlap included phase is yellow (or red clearance) and an overlap included phase is next. (3) when an overlap included phase is Walk. (4) when an overlap included phase is in a pedestrian clearance interval and an overlap included phase is next. Upon completion of the Walk interval, the overlap enters the pedestrian clearance interval. The overlap output shall exit the pedestrian clearance interval to steady Dont Walk when the programmed pedestrian clearance time expires. The overlap output shall be steady Dont Walk whenever the overlap Walk and pedestrian clearance are not ON. fYAThreeSection: The overlap output shall be controlled by the overlapIncludedPhases and the overlapModifierPhases if this type is indicated. It shall be used with a 3-section signal head where the overlap output drives the green arrow, combined yellow/flashing yellow arrow, and red arrow. The permissive through phase opposing the left-turn signal is the overlapIncludedPhases and the associated left-turn protected phase is the overlapModifierPhases. The overlap output shall be FYA in the following situations: (1) when an overlap included phase is green and an overlap modifier phase is NOT green. (2) when an overlap included phase is yellow (or red clearance), an overlap included phase is next or an overlap modifier phase is next, and a modifier phase is NOT green. The overlap output shall be yellow: (1) when an overlap included phase is yellow, an overlap included phase is not next, and an overlap modifier phase is NOT green. (2) when an overlap modifier phase is yellow. The overlap output shall be red: (1) when an overlap included phase is red, an overlap modifier phase is NOT green, and an overlap modifier phase is NOT yellow. (2) when an overlap modifier phase is timing a red- clearance interval. The overlap output shall be green: (1) when an overlap modifier phase is green. fYAFourSection: The overlap output shall be controlled by the overlapIncludedPhases and the overlapModifierPhases if this type is indicated. It shall be used with a 4-section signal head where the overlap output drives the flashing yellow arrow, yellow and red. The permissive through phase opposing the left-turn signal is the overlapIncludedPhases and the associated left-turn protected phase is the overlapModifierPhases. The overlap output shall be FYA in the following situations: (1) when an overlap included phase is green and an overlap modifier phase is NOT green. (2) when an overlap included phase is yellow (or red clearance), an overlap included phase or an overlap modifier phase is next and an overlap modifier phase is NOT green. The overlap output shall be yellow: (1) when an overlap included phase is yellow, an overlap included phase is not next, and an overlap modifier phase is NOT green. (2) when an overlap modifier phase is yellow. The overlap output shall be red: (1) when an overlap included phase is red, an overlap modifier phase is NOT green, and an overlap modifier phase is NOT yellow. (2) when an overlap modifier phase is timing a red- clearance interval. The overlap output shall be blank/dark: (1) when an overlap modifier phase is green fRAThreeSection: The overlap output shall be controlled by the overlapIncludedPhases and the overlapModifierPhases if this type is indicated. The overlap output drives the green arrow, yellow arrow, and combined red/flashing red arrow. The overlapIncludedPhases is an opposing through phase and the overlapModifierPhases is a protected left turn phase. The overlap output shall be green when an overlap modifier phase is green. The overlap output shall be yellow: (1) when an overlap modifier phase is yellow. (2) when an overlap modifier phase is red and an overlap included phase is yellow. The overlap output shall be red when the overlap modifier and included phases are red. The overlap output shall be flashing red when an overlap included phase is green and an overlap modifier phase is red. fRAFourSection: The overlap output shall be controlled by the overlapIncludedPhases and the overlapModifierPhases if this type is indicated. The overlap output drives the yellow arrow, red arrow, and flashing red arrow. The overlapIncludedPhases is an opposing through phase and the overlapModifierPhases is a protected left turn phase. The overlap outputs shall be blank when the overlapModifierPhase is green. The overlap output shall be yellow: (1) when an overlap modifier phase is yellow. (2) when an overlap modifier phase is red and an overlap included phase is yellow. The overlap output shall be red when an overlap modifier phase and an overlap included phase are red. The overlap output shall be flashing red when an overlap included phase is green and an overlap modifier phase is red. transit-2: The overlap output shall be controlled by the overlapIncludedPhases when this type is indicated. The overlap output drives a 2-section bar signal for transit vehicles using overlap green (vertical bar) and red (horizontal bar) outputs. The overlap output shall be green in the following situations: (1) when an overlap included phase is green. The overlap output shall be flashing green when an overlap included phase is yellow and an overlap included phase is not next. The overlap output shall be red whenever an overlap included phase is red. minusGreenYellowAlternate: The overlap output shall be controlled by the overlapIncludedPhases and the overlapModifierPhases if this type is indicated. The overlap output shall be green in the following situations: (1) when an overlap included phase is green and an overlap modifier phase is NOT green. (2) when an overlap included phase is yellow (or red clearance) and an overlap included phase is next and an overlap modifier phase is NOT green and an overlap modifier phase is not next. The overlap output shall be yellow when an overlap included phase is yellow and an overlap modifier phase is NOT yellow and an overlap included phase is not next. The overlap output shall be red whenever the overlap green and yellow are not ON. Note: Each enumeration requires the user to understand and avoid violation of MUTCD operational guidelines. 1.3.6.1.4.1.1206.4.2.1.9.2.1.2 P" ::= { overlapEntry 2 } overlapIncludedPhases OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION " Each octet is a Phase (number) that shall be an included phase for the overlap. The phase number value shall not exceed the maxPhases object value. 1.3.6.1.4.1.1206.4.2.1.9.2.1.3 P2" ::= { overlapEntry 3 } overlapModifierPhases OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION " Each octet is a Phase (number) that shall be a modifier phase for the overlap. The phase number value shall not exceed the maxPhases object value. The use of this object is defined by the overlapType. 1.3.6.1.4.1.1206.4.2.1.9.2.1.4 P2" ::= { overlapEntry 4 } overlapTrailGreen OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Overlap Trailing Green Parameter in seconds (0-255 sec). When this value is greater than zero and the overlap green (or walk) would normally terminate, the overlap green (or walk) shall be extended by this additional time. This is applicable to vehicle phases, bicycle phases, and transit phases. 1.3.6.1.4.1.1206.4.2.1.9.2.1.5 P second" ::= { overlapEntry 5 } overlapTrailYellow OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Overlap Trailing Yellow Change Parameter in tenth seconds (NEMA range: 3.0-25.5 sec). When the overlap green has been extended (Trailing Green), this value shall determine the current length of the Yellow Change interval for the overlap. This is applicable to vehicle phases, bicycle phases, and transit phases. 1.3.6.1.4.1.1206.4.2.1.9.2.1.6 P tenth second" ::= { overlapEntry 6 } overlapTrailRed OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Overlap Trailing Red Clear Parameter in tenth seconds (0-25.5 sec). When the overlap green has been extended (Trailing Green), this value shall determine the current length of the Red Clearance interval for the overlap. This is applicable to vehicle phases, bicycle phases, and transit phases. 1.3.6.1.4.1.1206.4.2.1.9.2.1.7 P tenth second" ::= { overlapEntry 7 } overlapWalk OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Overlap Walk Parameter in seconds (0-255 sec). This value is the length of the walk interval for a pedestrian overlap. Upon completion of the Walk interval, the overlap enters the pedestrian clearance interval. 1.3.6.1.4.1.1206.4.2.1.9.2.1.8 P second" ::= { overlapEntry 8 } overlapPedClearance OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Overlap Pedestrian Clearance Parameter in seconds (0-255 sec). This value is the length of the pedestrian clearance interval. 1.3.6.1.4.1.1206.4.2.1.9.2.1.9 P second" ::= { overlapEntry 9 } overlapConflictingPedPhases OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION " Each octet is a Phase (number) that shall be a pedestrian modifier phase for the overlap. The phase number value shall not exceed the maxPhases object value. If the overlap type is 'normal', a non-null value would suppress the overlap when the pedestrian phase is active (in the walk or clearance interval). Upon completion of the active pedestrian phase and upon completion of a clearance interval (MUTCD requires 3 seconds), the overlap is allowed to proceed to the green state. If the overlap type is fYAThreeSection or fYAFourSection, a non- null value would maintain the overlap red state when the pedestrian phase is active (in the walk or clearance interval). Upon completion of the active pedestrian phase and upon completion of a clearance interval (MUTCD requires 3 seconds), the overlap is allowed to proceed to the flashing yellow state. 1.3.6.1.4.1.1206.4.2.1.9.2.1.10 P2" ::= { overlapEntry 10 } maxOverlapStatusGroups OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The Maximum Number of Overlap Status Groups (8 overlaps per group) this Actuated Controller Unit supports. This value is equal to TRUNCATE [(maxOverlaps + 7) / 8]. This object indicates the maximum rows which shall appear in the overlapStatusGroupTable object. 1.3.6.1.4.1.1206.4.2.1.9.3 S group " ::= { overlap 3 } overlapStatusGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF OverlapStatusGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table containing Actuated Controller Unit overlap output (Red, Yellow, & Green) status in groups of eight overlaps. The number of rows in this table is equal to the maxOverlapStatusGroups object. static 1.3.6.1.4.1.1206.4.2.1.9.4" ::= { overlap 4 } overlapStatusGroupEntry OBJECT-TYPE SYNTAX OverlapStatusGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Red, Yellow, & Green Output Status for eight Actuated Controller Unit overlaps. 1.3.6.1.4.1.1206.4.2.1.9.4.1" INDEX { overlapStatusGroupNumber } ::= { overlapStatusGroupTable 1 } OverlapStatusGroupEntry ::= SEQUENCE { overlapStatusGroupNumber INTEGER, overlapStatusGroupReds INTEGER, overlapStatusGroupYellows INTEGER, overlapStatusGroupGreens INTEGER } overlapStatusGroupNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The overlap StatusGroup number for objects in this row. This value shall not exceed the maxOverlapStatusGroups object value. 1.3.6.1.4.1.1206.4.2.1.9.4.1.1 S group" ::= { overlapStatusGroupEntry 1 } overlapStatusGroupReds OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " Overlap Red Output Status Mask, when a bit=1, the Overlap Red is currently active. When a bit=0, the Overlap Red is NOT currently active. Bit 7: Overlap # = (overlapStatusGroupNumber * 8) Bit 6: Overlap # = (overlapStatusGroupNumber * 8) - 1 Bit 5: Overlap # = (overlapStatusGroupNumber * 8) - 2 Bit 4: Overlap # = (overlapStatusGroupNumber * 8) - 3 Bit 3: Overlap # = (overlapStatusGroupNumber * 8) - 4 Bit 2: Overlap # = (overlapStatusGroupNumber * 8) - 5 Bit 1: Overlap # = (overlapStatusGroupNumber * 8) - 6 Bit 0: Overlap # = (overlapStatusGroupNumber * 8) - 7 1.3.6.1.4.1.1206.4.2.1.9.4.1.2 S" ::= { overlapStatusGroupEntry 2 } overlapStatusGroupYellows OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " Overlap Yellow Output Status Mask, when a bit=1, the Overlap Yellow is currently active. When a bit=0, the Overlap Yellow is NOT currently active. Bit 7: Overlap # = (overlapStatusGroupNumber * 8) Bit 6: Overlap # = (overlapStatusGroupNumber * 8) - 1 Bit 5: Overlap # = (overlapStatusGroupNumber * 8) - 2 Bit 4: Overlap # = (overlapStatusGroupNumber * 8) - 3 Bit 3: Overlap # = (overlapStatusGroupNumber * 8) - 4 Bit 2: Overlap # = (overlapStatusGroupNumber * 8) - 5 Bit 1: Overlap # = (overlapStatusGroupNumber * 8) - 6 Bit 0: Overlap # = (overlapStatusGroupNumber * 8) - 7 For pedestrianNormal overlap type, this object is used to represent the pedestrian clearance interval. 1.3.6.1.4.1.1206.4.2.1.9.4.1.3 S" ::= { overlapStatusGroupEntry 3 } overlapStatusGroupGreens OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " Overlap Green Output Status Mask, when a bit=1, the Overlap Green is currently active. When a bit=0, the Overlap Green is NOT currently active. Bit 7: Overlap # = (overlapStatusGroupNumber * 8) Bit 6: Overlap # = (overlapStatusGroupNumber * 8) - 1 Bit 5: Overlap # = (overlapStatusGroupNumber * 8) - 2 Bit 4: Overlap # = (overlapStatusGroupNumber * 8) - 3 Bit 3: Overlap # = (overlapStatusGroupNumber * 8) - 4 Bit 2: Overlap # = (overlapStatusGroupNumber * 8) - 5 Bit 1: Overlap # = (overlapStatusGroupNumber * 8) - 6 Bit 0: Overlap # = (overlapStatusGroupNumber * 8) - 7 1.3.6.1.4.1.1206.4.2.1.9.4.1.4 S" ::= { overlapStatusGroupEntry 4 } ts2port1 OBJECT IDENTIFIER ::= { asc 10 } -- This object is an identifier used to group all objects for -- support of NEMA TS 2 (Clause 3.3.1) Port 1 activities. maxPort1Addresses OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The Maximum Number of Port 1 addresses this Actuated Controller Unit supports. This object indicates the maximum rows which shall appear in the port1Table object. 1.3.6.1.4.1.1206.4.2.1.10.1 S address" ::= { ts2port1 1 } port1Table OBJECT-TYPE SYNTAX SEQUENCE OF Port1Entry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table containing Actuated Controller Unit port 1 parameters. The number of rows in this table is equal to maxPort1Addresses object. Address 255 is reserved for the all stations (link devices) address. static 1.3.6.1.4.1.1206.4.2.1.10.2" ::= { ts2port1 2 } port1Entry OBJECT-TYPE SYNTAX Port1Entry ACCESS not-accessible STATUS mandatory DESCRIPTION " This object defines a conceptual row in the port 1 Table. 1.3.6.1.4.1.1206.4.2.1.10.2.1" INDEX { port1Number } ::= { port1Table 1 } Port1Entry ::= SEQUENCE { port1Number INTEGER, port1DevicePresent INTEGER, port1Frame40Enable INTEGER, port1Status INTEGER, port1FaultFrame INTEGER } port1Number OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The (Port 1 address plus one) for objects in this row. This value shall not exceed the maxPort1Addresses object value. 1.3.6.1.4.1.1206.4.2.1.10.2.1.1 S address" ::= { port1Entry 1 } port1DevicePresent OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-write STATUS mandatory DESCRIPTION " This object is used to program the CU as to the presence or absence of a device for this Port 1 address. The CU shall transmit Command Frames only to those devices that are present as determined by this programming. True (one) - the device is present. False (zero) - the device is not present. 1.3.6.1.4.1.1206.4.2.1.10.2.1.2 P" REFERENCE "NEMA TS 2 Clause 3.3.1.4" ::= { port1Entry 2 } port1Frame40Enable OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-write STATUS mandatory DESCRIPTION " To enable or disable Frame 40 messages to the device at this Port 1 address. Frame 40 is used to poll the secondary stations for a secondary to secondary message exchange. Command 40 series frames shall be transmitted only to those devices that are enabled, as determined by this programming. TRUE (one) - Enable frame 40 messages for this device. FALSE (zero) - Disable frame 40 messages for this device. 1.3.6.1.4.1.1206.4.2.1.10.2.1.3 P" REFERENCE "NEMA TS 2 Clause 3.3.1.4.1" ::= { port1Entry 3 } port1Status OBJECT-TYPE SYNTAX INTEGER { other (1), online (2), responseFault (3) } ACCESS read-only STATUS mandatory DESCRIPTION " This object indicates the communications status with the associated device: other: This indicates that some other communications fault has been detected. online: This indicates that at least five of the most recent 10 response transfers were received correctly. responseFault: This indicates that more than 5 of the most recent 10 response transfers were received incorrectly. 1.3.6.1.4.1.1206.4.2.1.10.2.1.4 S" ::= { port1Entry 4 } port1FaultFrame OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " This object indicates the frame number that caused the most recent fault. 1.3.6.1.4.1.1206.4.2.1.10.2.1.5 S" ::= { port1Entry 5 } ascBlock OBJECT IDENTIFIER ::= { asc 11 } -- This object is an identifier used to group all objects for -- support of ASC Block Upload and Download activities. ascBlockGetControl OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4..12)) ACCESS read-write STATUS mandatory DESCRIPTION " An OER encoded string of reference parameters for ASC Block Uploads. The parameter values in this string are: ascBlockDataType INTEGER (0..255) ascBlockDataID INTEGER (0..255) ascBlockIndex1 INTEGER (0..255) if needed ascBlockQuantity1 INTEGER (0..255) if needed ascBlockIndex2 INTEGER (0..255) if needed ascBlockQuantity2 INTEGER (0..255) if needed ascBlockIndex3 INTEGER (0..255) if needed ascBlockQuantity3 INTEGER (0..255) if needed ascBlockIndex4 INTEGER (0..255) if needed ascBlockQuantity4 INTEGER (0..255) if needed ascBlockIndex5 INTEGER (0..255) if needed ascBlockQuantity5 INTEGER (0..255) if needed A GET of ascBlockData shall utilize values currently in this object to define the data to be returned. A SET of this object shall be evaluated for validity and Error Status of badValue(3) be returned for the following conditions: 1) ascBlockDataType is not supported 2) ascBlockDataID is not supported 3) ascBlockIndex1 is zero or not supported 4) ascBlockQuantity1 is zero or ascBlockIndex1 + ascBlockQuantity1 - 1 is not supported 5) ascBlockIndex2 is zero or not supported 6) ascBlockQuantity2 is zero or ascBlockIndex2 + ascBlockQuantity2) - 1 is not supported 7) ascBlockIndex3 is zero or not supported 8) ascBlockQuantity3 is zero or ascBlockIndex3 + scBlockQuantity3) - 1 is not supported 9) ascBlockIndex4 is zero or not supported 10) ascBlockQuantity4 is zero or ascBlockIndex4 + ascBlockQuantity4) - 1 is not supported 11) ascBlockIndex5 is zero or not supported 12) ascBlockQuantity5 is zero or ascBlockIndex5 + scBlockQuantity5) - 1 is not supported 13) if the SET length is zero or incorrect for ascBlockDataType & ascBlockDataID 14) if the GetResponse length for a GET on ascBlockData using maximum data field sizes would exceed a local limitation When this validity check fails, ascBlockErrorStatus shall be set equal to the Bullet Value above that generated the error. 1.3.6.1.4.1.1206.4.2.1.11.1 C " ::= { ascBlock 1 } ascBlockData OBJECT-TYPE SYNTAX OCTET STRING (SIZE(6..65535)) ACCESS read-write STATUS mandatory DESCRIPTION " An OER encoded string used for uploading and downloading ASC parameters. See SECTION 6 for encoding and decoding the block. A SET on this object shall require the use of 'dbCreateTransaction' defined in NTCIP 1201 Clause 2.3.1. A SET of this object shall be evaluated for validity and Error Status of badValue(3) be returned for the following conditions: 1) ascBlockDataType is not supported 2) ascBlockDataID is not supported 3) ascBlockIndex1 is zero or not supported 4) ascBlockQuantity1 is zero or ascBlockIndex1 + ascBlockQuantity1 - 1 is not supported 5) ascBlockIndex2 is zero or not supported 6) ascBlockQuantity2 is zero or ascBlockIndex2 + ascBlockQuantity2) - 1 is not supported 7) ascBlockIndex3 is zero or not supported 8) ascBlockQuantity3 is zero or ascBlockIndex3 + ascBlockQuantity3) - 1 is not supported 9) ascBlockIndex4 is zero or not supported 10) ascBlockQuantity4 is zero or ascBlockIndex4 + ascBlockQuantity4) - 1 is not supported 11) ascBlockIndex5 is zero or not supported 12) ascBlockQuantity5 is zero or ascBlockIndex5 + ascBlockQuantity5) - 1 is not supported 13) if the SET length is zero or incorrect for ascBlockDataType & ascBlockDataID 14) if the SET (SEQUENCE OF) value is incorrect. When this validity check fails, ascBlockErrorStatus shall be set equal to the Bullet Value above that generated the error. A SET that includes an unsupported value for a supported data element shall return an Error Status of badValue(3) and ascBlockErrorStatus shall be set equal to: (data Sequence # * 100) + data Element # A SET that includes a non-zero or non-null value in the position of an unsupported data element shall return an Error Status of badValue(3) and ascBlockErrorStatus shall be set equal to: (data Sequence # * 100) + data Element # A GET on this object shall utilize values currently in ascBlockGetControl to define the data to be returned. When ascBlockGetControl has invalid data, an Error STATUS of badValue(3) shall be returned. A GET shall return a zero or null value in the position of an unsupported object. 1.3.6.1.4.1.1206.4.2.1.11.2 C " ::= { ascBlock 2 } ascBlockErrorStatus OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION " This object defines the data element within ascBlockGetControl or ascBlockData that caused a badValue(3) ErrorStatus. This object should equal zero after any successful SET to ascBlockGetControl or ascBlockData. 1.3.6.1.4.1.1206.4.2.1.11.3 S" ::= { ascBlock 3 } cabinetEnvironment OBJECT IDENTIFIER ::= { asc 12 } -- This node contains objects that monitor and control the cabinet -- environment functions for this device. maxCabinetEnvironDevices OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The maximum number of environmental monitoring devices this CU supports. This object indicates the maximum rows which shall appear in the cabinetEnvironDevicesTable object. 1.3.6.1.4.1.1206.4.2.1.12.1 S number" ::= { cabinetEnvironment 1 } cabinetEnvironDevicesTable OBJECT-TYPE SYNTAX SEQUENCE OF CabinetEnvironDeviceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table containing the parameters of the environmental monitoring devices contained in the cabinet. The number of rows in this table is equal to the maxCabinetEnvironDevices object. 1.3.6.1.4.1.1206.4.2.1.12.2 static" ::= { cabinetEnvironment 2 } cabinetEnvironDeviceEntry OBJECT-TYPE SYNTAX CabinetEnvironDeviceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Parameters for a specific CU cabinet environmental condition monitoring device. 1.3.6.1.4.1.1206.4.2.1.12.2.1" INDEX { cabinetEnvironDeviceNumber, cabinetEnvironDeviceIndex } ::= { cabinetEnvironDevicesTable 1 } CabinetEnvironDeviceEntry ::= SEQUENCE { cabinetEnvironDeviceNumber INTEGER, cabinetEnvironDeviceType INTEGER, cabinetEnvironDeviceIndex INTEGER, cabinetEnvironDeviceDescription DisplayString, cabinetEnvironDeviceOnStatus INTEGER, cabinetEnvironDeviceErrorStatus INTEGER } cabinetEnvironDeviceNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The environmental monitoring number for objects in this row. This value shall not exceed the maxCabinetEnvironDevices object value. 1.3.6.1.4.1.1206.4.2.1.12.2.1.1 S monitoring device" ::= { cabinetEnvironDeviceEntry 1 } cabinetEnvironDeviceType OBJECT-TYPE SYNTAX INTEGER { other (1), door (2), fan (3), heater (4), floatSwitch (5)} ACCESS read-write STATUS mandatory DESCRIPTION " The type of environment monitoring device to monitor the cabinet is an enumerated integer. other: the type of environmental monitoring device is not defined by this standard. door: this cabinet environmental monitoring device is a door to the cabinet. fan: this cabinet environmental monitoring device is a fan within the cabinet. heater: this cabinet environmental monitoring device is a heater within the cabinet. floatSwitch: this cabinet environmental monitoring device is a float switch for water level detection. 1.3.6.1.4.1.1206.4.2.1.12.2.1.2 P" ::= { cabinetEnvironDeviceEntry 2 } cabinetEnvironDeviceIndex OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The index for the cabinetEnvironDeviceType. This value allows support for multiple sensors of a specific environment monitoring device type. 1.3.6.1.4.1.1206.4.2.1.12.2.1.3 S" ::= { cabinetEnvironDeviceEntry 3 } cabinetEnvironDeviceDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION " Human-readable description of the cabinet environmental device. This value should provide enough information for maintenance personnel to identify the type (door, fan, heater, etc.) and physical location of the device defined in this row within the CU or CU cabinet. 1.3.6.1.4.1.1206.4.2.1.12.2.1.4 S" ::= { cabinetEnvironDeviceEntry 4 } cabinetEnvironDeviceOnStatus OBJECT-TYPE SYNTAX INTEGER { true (1), false (2) } ACCESS read-only STATUS mandatory DESCRIPTION " Indicates if this environmental monitoring device is on/open or off/closed. A bit orientation of 1 (true) indicates the environmental monitoring device is on, or in the case of a door, the door is open. A value of 0 (false) indicates this environmental monitoring device is off, or in the case of a door, the door is closed. 1.3.6.1.4.1.1206.4.2.1.12.2.1.5 S" ::= { cabinetEnvironDeviceEntry 5 } cabinetEnvironDeviceErrorStatus OBJECT-TYPE SYNTAX INTEGER { other (1), --not used noError (2), fail (3), notMonitored (4) } ACCESS read-only STATUS mandatory DESCRIPTION " Indicates the current status of the environmental monitoring device. 1.3.6.1.4.1.1206.4.2.1.12.2.1.6 S" ::= { cabinetEnvironDeviceEntry 6 } maxCabinetTempSensors OBJECT-TYPE SYNTAX INTEGER (0..16) ACCESS read-only STATUS mandatory DESCRIPTION " Indicates the number of rows in the cabinetTempSensorStatusTable. 1.3.6.1.4.1.1206.4.2.1.12.3 S temperature sensors" ::= { cabinetEnvironment 3 } cabinetTempSensorStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF CabinetTempSensorStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table containing status information for each temperature sensor within a CU and CU cabinet. static 1.3.6.1.4.1.1206.4.2.1.12.4" ::= { cabinetEnvironment 4 } cabinetTempSensorStatusEntry OBJECT-TYPE SYNTAX CabinetTempSensorStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " An entry in the cabinet temperature sensor status table. 1.3.6.1.4.1.1206.4.2.1.12.4.1" INDEX { cabinetTempSensorIndex } ::= { cabinetTempSensorStatusTable 1} CabinetTempSensorStatusEntry ::= SEQUENCE { cabinetTempSensorIndex INTEGER, cabinetTempSensorDescription DisplayString, cabinetTempSensorCurrentReading INTEGER, cabinetTempSensorHighThreshold INTEGER, cabinetTempSensorLowThreshold INTEGER, cabinetTempSensorStatus INTEGER } cabinetTempSensorIndex OBJECT-TYPE SYNTAX INTEGER (1..16) ACCESS read-only STATUS mandatory DESCRIPTION " Index of the cabinet temperature sensor status table. This value shall not exceed maxCabinetTempSensors. 1.3.6.1.4.1.1206.4.2.1.12.4.1.1 S" ::= { cabinetTempSensorStatusEntry 1 } cabinetTempSensorDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION " Human-readable description of the temperature sensor. This value should provide enough information for maintenance personnel to identify the physical location of the temperature sensor within the CU or CU cabinet. 1.3.6.1.4.1.1206.4.2.1.12.4.1.2 S" ::= { cabinetTempSensorStatusEntry 2 } cabinetTempSensorCurrentReading OBJECT-TYPE SYNTAX INTEGER (-128..127) ACCESS read-only STATUS mandatory DESCRIPTION " Indicates the current reading, in degrees Celsius, of the temperature sensor. The value -127 shall indicate a temperature of -127 degrees Celsius or lower. The value 127 shall indicate a temperature of 127 degrees Celsius or higher. The value -128 shall indicate an error condition or missing value. 1.3.6.1.4.1.1206.4.2.1.12.4.1.3 S degrees Celsius" DEFVAL { -56 } ::= { cabinetTempSensorStatusEntry 3 } cabinetTempSensorHighThreshold OBJECT-TYPE SYNTAX INTEGER (-128..127) ACCESS read-write STATUS mandatory DESCRIPTION " Indicates the high value of the temperature, in degrees Celsius, associated with this temperature sensor above which would generate a warning (Bit 3 of unitAlarmStatus4). This value should not be lower than the value of the cabinetTempSensorLowThreshold object. 1.3.6.1.4.1.1206.4.2.1.12.4.1.4 P degrees Celsius" ::= { cabinetTempSensorStatusEntry 4 } cabinetTempSensorLowThreshold OBJECT-TYPE SYNTAX INTEGER (-128..127) ACCESS read-write STATUS mandatory DESCRIPTION " Indicates the low value of the temperature, in degrees Celsius, associated with this temperature sensor below which would generate a warning (Bit 3 of unitAlarmStatus4). This value should not be higher than the value of the cabinetTempSensorHighThreshold object. 1.3.6.1.4.1.1206.4.2.1.12.4.1.5 P degrees Celsius" ::= { cabinetTempSensorStatusEntry 5 } cabinetTempSensorStatus OBJECT-TYPE SYNTAX INTEGER { other (1), noError (2), fail (3) } ACCESS read-only STATUS mandatory DESCRIPTION " Indicates the current status of the indicated temperature sensor. 1.3.6.1.4.1.1206.4.2.1.12.4.1.6 P" ::= { cabinetTempSensorStatusEntry 6 } maxCabinetHumiditySensors OBJECT-TYPE SYNTAX INTEGER (0..16) ACCESS read-only STATUS mandatory DESCRIPTION " Indicates the number of rows in the cabinetHumiditySensorStatusTable. 1.3.6.1.4.1.1206.4.2.1.12.5 P humidity sensors" ::= { cabinetEnvironment 5 } cabinetHumiditySensorStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF CabinetHumiditySensorStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table containing status information for each humidity sensor within a CU cabinet.
static 1.3.6.1.4.1.1206.4.2.1.12.6" ::= { cabinetEnvironment 6 } cabinetHumiditySensorStatusEntry OBJECT-TYPE SYNTAX CabinetHumiditySensorStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " An entry in the humidity sensor status table. 1.3.6.1.4.1.1206.4.2.1.12.6.1" INDEX { cabinetHumiditySensorIndex } ::= { cabinetHumiditySensorStatusTable 1} CabinetHumiditySensorStatusEntry ::= SEQUENCE { cabinetHumiditySensorIndex INTEGER, cabinetHumiditySensorDescription DisplayString, cabinetHumiditySensorCurrentReading INTEGER, cabinetHumidityThreshold INTEGER, cabinetHumiditySensorStatus INTEGER } cabinetHumiditySensorIndex OBJECT-TYPE SYNTAX INTEGER (1..16) ACCESS read-only STATUS mandatory DESCRIPTION " Index of the humidity sensor status table. This value does not exceed maxCabinetHumiditySensors. 1.3.6.1.4.1.1206.4.2.1.12.6.1.1 S" ::= { cabinetHumiditySensorStatusEntry 1 } cabinetHumiditySensorDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION " Human-readable description of the humidity sensor. This value should provide enough information for maintenance personnel to identify the physical location of the humidity sensor within the CU cabinet. 1.3.6.1.4.1.1206.4.2.1.12.6.1.2 P" ::= { cabinetHumiditySensorStatusEntry 2 } cabinetHumiditySensorCurrentReading OBJECT-TYPE SYNTAX INTEGER (0..101) ACCESS read-only STATUS mandatory DESCRIPTION " Indicates the current reading of the humidity sensor, in percent relative humidity. The value 101 shall indicate an error condition or missing value. 1.3.6.1.4.1.1206.4.2.1.12.6.1.3 S percent relative humidity" DEFVAL { 101 } ::= { cabinetHumiditySensorStatusEntry 3 } cabinetHumidityThreshold OBJECT-TYPE SYNTAX INTEGER (0..101) ACCESS read-write STATUS mandatory DESCRIPTION " Indicates the relative humidity, in percent, within the CU cabinet above which the humidity threshold alarm shall be activated (Bit 3 of unitAlarmStatus4). 1.3.6.1.4.1.1206.4.2.1.12.6.1.4 P percent humidity" ::= { cabinetHumiditySensorStatusEntry 4 } cabinetHumiditySensorStatus OBJECT-TYPE SYNTAX INTEGER { other (1), --not used noError (2), fail (3) } ACCESS read-only STATUS mandatory DESCRIPTION " Indicates the current status of the indicated humidity sensor. 1.3.6.1.4.1.1206.4.2.1.12.6.1.5 S" ::= { cabinetHumiditySensorStatusEntry 5 } ascPowerSource OBJECT-TYPE SYNTAX INTEGER { unknown (1), other (2), acLine (3), generator (4), solar (5), battery-UPS (6), dc48VPower (7), dc24Vpower (8) } ACCESS read-only STATUS mandatory DESCRIPTION " Integer value that indicates the current primary power source for the CU cabinet, expressed as an enumerated integer. unknown: the current primary power source is unknown or cannot be determined. other: the current primary power source is not defined by this standard. acLine: the current primary power source is in-line AC power. generator: the current primary power source is a generator that is operational. solar: the current primary power source is solar equipment, that may be have a battery as an intermediary. battery-UPS: the current primary power source is a battery or UPS with no significant charging occurring. dc48VPower: the current primary power source is 48 volts DC directly into the cabinet. dc24VPower: the current primary power source is 48 volts DC directly into the cabinet. 1.3.6.1.4.1.1206.4.2.1.12.7 S" DEFVAL { unknown } ::= { cabinetEnvironment 7 } ascLineVolts OBJECT-TYPE SYNTAX INTEGER (0..6001) ACCESS read-only STATUS mandatory DESCRIPTION " Indicates the voltage, in 0.1 RMS volt units, measured on the incoming power line for the CU. This object shall only be used to indicate A/C power conditions. If the line power is DC, this object shall not apply (i.e., this object will either not be supported or this object will have a value of 3001). Values 0 through 5999 shall indicate valid values. The value 6000 shall mean a voltage of 600.0 Vrms or greater. The value of 6001 shall indicate an error condition or missing value. 1.3.6.1.4.1.1206.4.2.1.12.8 S 0.1 Volts Root Mean Squared (Vrms)" DEFVAL { 6001 } ::= { cabinetEnvironment 8 } atccLEDMode OBJECT-TYPE SYNTAX INTEGER { other (1), on (2), off (3) } ACCESS read-write STATUS mandatory DESCRIPTION " Object that allows control of the LED displays within an ATC cabinet. other: LED mode of operation is not defined by this standard. on: ATCC module LEDs operate normally (e.g., full brightness and flashing are prescribed by module documentation). off: ATCC module LEDs are off (sleep) when all cabinet door(s) are closed. All other values are RESERVED. 1.3.6.1.4.1.1206.4.2.1.12.9 P" ::= { cabinetEnvironment 9 } ascIOmapping OBJECT IDENTIFIER ::= { asc 13 } -- This node contains objects that configure, monitor or control input and -- output mapping in the ASC ascIOmapControl OBJECT IDENTIFIER ::= { ascIOmapping 1 } -- This node contains objects that control the current I/O map ascIOmaxMaps OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " This object contains the maximum number of I/O maps this ASC supports. This object indicates the number of rows in the ascIOmapsTable. 1.3.6.1.4.1.1206.4.2.1.13.1.1 S" ::= { ascIOmapControl 1 } ascIOactiveMap OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION " This object selects the active I/O map. This object has to be changed as part of a 1201 Database Transaction (see the dbCreateTransaction object). A Database Transaction that changes this object or edits the currently active I/O map has to satisfy the activation requirements in ascIOactivateRequirement at the time dbCreateTransaction is set to verify (3) for the transaction to successfully verify. The value of this object cannot exceed the value of ascIOmaxMaps. 1.3.6.1.4.1.1206.4.2.1.13.1.2 S" DEFVAL { 1 } ::= { ascIOmapControl 2 } ascIOactivateRequirement OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " This object returns the conditions under which an ASC will confirm a DB transaction that activates a new I/O map or edits the currently active I/O map. The requirements are selected in a bitmap format: Bit 0 - cabinetDoorOpen -- I/O input cabinetDoorOpen active Bit 1 - inFlash -- in any flash state Bit 2 - allRedFlash -- in programmed all red flash Bit 3 - cabinetFlash -- in CVM flash, input localFlashSense active Bit 4 - restart -- changes take effect only after a restart Bit 5 - reserved Bit 6 - reserved Bit 7 - reserved Note: if all I/O mapping values being set are the same as the current values, the DB transaction shall succeed without requiring any conditions set by this object. 1.3.6.1.4.1.1206.4.2.1.13.1.3 S" ::= { ascIOmapControl 3 } ascIOmapMaxInputs OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION " This object contains the maximum number of I/O mapping input functions this ASC supports. This object indicates the number of rows in the ascIOinputMapTable. 1.3.6.1.4.1.1206.4.2.1.13.2 S" ::= { ascIOmapping 2 } ascIOmapMaxOutputs OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION " This object contains the maximum number of I/O mapping output functions this ASC supports. This object indicates the number of rows in the ascIOoutputMapTable. 1.3.6.1.4.1.1206.4.2.1.13.3 S" ::= { ascIOmapping 3 } ascIOinputMapTable OBJECT-TYPE SYNTAX SEQUENCE OF AscIOinputMapTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table containing mapping for an ASC Controller's inputs to functions. The number of I/O input map tables is equal to the value of ascIOmaxMaps. The total number of rows in the table is ascIOmapMaxInputs. Only one I/O input map may be active at any one time, and is selected by ascIOactiveMap. static 1.3.6.1.4.1.1206.4.2.1.13.4" ::= { ascIOmapping 4 } ascIOinputMapTableEntry OBJECT-TYPE SYNTAX AscIOinputMapTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " This object defines a conceptual row in the ascIOinputMapTable. 1.3.6.1.4.1.1206.4.2.1.13.4.1" INDEX { ascIOmapNumber, ascIOinputMapIOindex } ::= { ascIOinputMapTable 1 } AscIOinputMapTableEntry ::= SEQUENCE { ascIOmapNumber INTEGER, -- up to ascIOmaxMaps ascIOinputMapIOindex INTEGER, -- up to ascIOmapMaxInputs ascIOinputMapDeviceType INTEGER, -- enum custom, FIO,TS1,BIU,SIU,AUX, reserved ascIOinputMapDevicePNN INTEGER, -- NEMA PNN if DeviceType is custom ascIOinputMapDevicePtype INTEGER, -- Custom device type ascIOinputMapDeviceAddr INTEGER, -- only used if needed (BIU, SIU) ascIOinputMapDevicePin INTEGER, -- device I/O pin index ascIOinputMapFuncType INTEGER, -- 0=STD, else nemaPrivate vendor code ascIOinputMapFuncPtype INTEGER, -- Custom function type set ascIOinputMapFunction INTEGER, -- function ascIOinputMapFuncIndex INTEGER } -- index if function support more than one input or output ascIOmapNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The value of this object shall not exceed the ascIOmaxMaps value. 1.3.6.1.4.1.1206.4.2.1.13.4.1.1 S" ::= { ascIOinputMapTableEntry 1 } ascIOinputMapIOindex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION " The I/O index for this row of the table. The range will not exceed ascIOmapMaxInputs. 1.3.6.1.4.1.1206.4.2.1.13.4.1.2 S " ::= { ascIOinputMapTableEntry 2 } ascIOinputMapDeviceType OBJECT-TYPE SYNTAX INTEGER { unused (1), custom (2), fio (3), ts1 (4), biu (5), siu (6), aux (7) } ACCESS read-write STATUS mandatory DESCRIPTION " This object is an selects the device type for this row of the table. A value of unused (1) means that this row of the table is unused (all values of ascIOinputMapIOindex up to ascIOmapMaxInputs may not be needed by every mapping). A custom type is a manufacturer defined device which also requires a ascIOinputMapDevicePNN and a ascIOinputMapDevicePtype to fully specify the device. Values > 7 are reserved for future device types. 1.3.6.1.4.1.1206.4.2.1.13.4.1.3 P" ::= { ascIOinputMapTableEntry 3 } ascIOinputMapDevicePNN OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION " The object is used to further define a device type when ascIOinputMapDeviceType is custom (2). The value of this object will be the manufacturer's Private Node Number (PNN) as assigned by NEMA (1.3.6.1.4.1.1206.3.PNN). This is the same identifier used for ASC custom blocks. 1.3.6.1.4.1.1206.4.2.1.13.4.1.4 P" ::= { ascIOinputMapTableEntry 4 } ascIOinputMapDevicePtype OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " The object is used to further define a device type when ascIOinputMapDeviceType is custom (2). The value of this object will identify a custom device type unique to the manufacturer specified by ascIOinputMapDevicePNN. 1.3.6.1.4.1.1206.4.2.1.13.4.1.5 P" ::= { ascIOinputMapTableEntry 5 } ascIOinputMapDeviceAddr OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " An address for the device at this table row. The address is used for devices like BIUs and SIUs that require an address. The value should be zero if the address is not needed for this row. If the ascIOinputMapDeviceType is biu (4), the address values are: 1 - Traffic Facilities BIU #1 2 - Traffic Facilities BIU #2 3 - Traffic Facilities BIU #3 4 - Traffic Facilities BIU #4 5-8 - reserved 9 - Detector BIU #1 10 - Detector BIU #2 11 - Detector BIU #3 12 - Detector BIU #4 13-16 - reserved Note that these values are the BIU SDLC address + 1. If the ascIOinputMapDeviceType is siu (5), the address values are: 1 - reserved 2 - 14-pack output SIU position 1 3 - reserved 4 - 14-pack output SIU position 3 5 - 6-pack output SIU position 4 6 - 6-pack output SIU position 1 7 - 6-pack output SIU position 2 8 - 6-pack output SIU position 3 9 - reserved 10 - input SIU #1 11 - input SIU #2 12 - input SIU #3 13 - input SIU #4 14 - input SIU #5 15 - reserved Note that these values are the SIU SDLC address + 1. 1.3.6.1.4.1.1206.4.2.1.13.4.1.6 P" ::= { ascIOinputMapTableEntry 6 } ascIOinputMapDevicePin OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " An index for the I/O pin at this table row. The range for this value will depend upon the value of other objects in the row. The range for ascIOinputMapDeviceType: fio (3) pin range is AscIOmapFIOinputs ts1 (4) pin range is AscIOmapTS1inputs biu (5) pin range is AscIOmapBIUinputs siu (6) pin range is AscIOmapSIUinputs aux (7) pin range is AscIOmapAUXinputs The range for a custom device type will be determined by the manufacturer defining it. 1.3.6.1.4.1.1206.4.2.1.13.4.1.7 P" ::= { ascIOinputMapTableEntry 7 } ascIOinputMapFuncType OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION " This object selects the function type for this row of the table. A value of 0 references the standard input functions defined by AscIOinputType and the ascIOinputMapFunction. Any other value is a manufacturer's Private Node Number (PNN) as assigned by NEMA (1.3.6.1.4.1.1206.3.PNN). In this case the function is defined by the PNN (the manufacturer), ascIOinputMapFuncPtype (which of the manufacturer's multiple function sets), and the ascIOinputMapFunction. 1.3.6.1.4.1.1206.4.2.1.13.4.1.8 P" ::= { ascIOinputMapTableEntry 8 } ascIOinputMapFuncPtype OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " The object is used to further define a function type when ascIOinputMapFuncType is not zero. The value of this object will identify a custom function type unique to the manufacturer specified by ascIOinputMapDevicePNN. This allows a manufacturer to have multiple sets of functions for their one Private Node Number. 1.3.6.1.4.1.1206.4.2.1.13.4.1.9 P" ::= { ascIOinputMapTableEntry 9 } ascIOinputMapFunction OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " This object specifies the function that is mapped to the I/O pin specified by this row. For example, if ascIOinputMapFuncType is zero (standard) then the function could be any AscIOinputType value such as vehicleDetector (51). 1.3.6.1.4.1.1206.4.2.1.13.4.1.10 P" ::= { ascIOinputMapTableEntry 10 } ascIOinputMapFuncIndex OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " An index for the function at this table row. For example, if ascIOinputMapFuncType is zero (standard) and the ascIOinputMapFunction is vehicleDetector (51) then this index will determine which detector input it is (1 to maxVehicleDetectors). 1.3.6.1.4.1.1206.4.2.1.13.4.1.11 P" ::= { ascIOinputMapTableEntry 11 } ascIOinputMapStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF AscIOinputMapStatusTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table containing status for the current mapping for an ASC controller's inputs. static 1.3.6.1.4.1.1206.4.2.1.13.5" ::= { ascIOmapping 5 } ascIOinputMapStatusTableEntry OBJECT-TYPE SYNTAX AscIOinputMapStatusTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " This object defines a conceptual row in the ascIOinputMapStatusTable. 1.3.6.1.4.1.1206.4.2.1.13.5.1" INDEX { ascIOmapNumber, ascIOinputMapIOindex } ::= { ascIOinputMapStatusTable 1 } AscIOinputMapStatusTableEntry ::= SEQUENCE { ascIOinputMapDevPinDescr OCTET STRING, -- description of input pin ascIOinputMapDevPinStatus INTEGER } -- 0 or 1 for active ascIOinputMapDevPinDescr OBJECT-TYPE SYNTAX OCTET STRING (SIZE (32)) ACCESS read-only STATUS mandatory DESCRIPTION " This object returns the name of the input pin, such as 'C1-39 Detector 2'. Since the physical pins are determined by the controller hardware, the value is read-only. 1.3.6.1.4.1.1206.4.2.1.13.5.1.1 S" ::= { ascIOinputMapStatusTableEntry 1 } ascIOinputMapDevPinStatus OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-only STATUS mandatory DESCRIPTION " This object returns the current status of an input pin: inactive/OFF (0) or active/ON (1). 1.3.6.1.4.1.1206.4.2.1.13.5.1.2 S" ::= { ascIOinputMapStatusTableEntry 2 } ascIOoutputMapTable OBJECT-TYPE SYNTAX SEQUENCE OF AscIOoutputMapTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table containing mapping for an ASC Controller's inputs and outputs to functions. The number of I/O map tables is equal to the value of ascIOmaxMaps. The total number of rows in the table is ascIOmapMaxOutputs. Only one I/O map may be active at any one time, and is selected by ascIOactiveMap. static 1.3.6.1.4.1.1206.4.2.1.13.6" ::= { ascIOmapping 6 } ascIOoutputMapTableEntry OBJECT-TYPE SYNTAX AscIOoutputMapTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " This object defines a conceptual row in the ascIOoutputMapTable. 1.3.6.1.4.1.1206.4.2.1.13.6.1" INDEX { ascIOmapNumber, ascIOoutputMapIOindex } ::= { ascIOoutputMapTable 1 } AscIOoutputMapTableEntry ::= SEQUENCE { ascIOoutputMapIOindex INTEGER, -- up to ascIOmapMaxOutputs ascIOoutputMapDeviceType INTEGER, -- enum custom, FIO,TS1,BIU,SIU,AUX, reserved ascIOoutputMapDevicePNN INTEGER, -- NEMA PNN if DeviceType is custom ascIOoutputMapDevicePtype INTEGER, -- Custom device type ascIOoutputMapDeviceAddr INTEGER, -- only used if needed (BIU, SIU) ascIOoutputMapDevicePin INTEGER, -- device I/O pin index ascIOoutputMapFuncType INTEGER, -- 0=STD, else nemaPrivate vendor code ascIOoutputMapFuncPtype INTEGER, -- Custom function type ascIOoutputMapFunction INTEGER, -- function ascIOoutputMapFuncIndex INTEGER } -- index if function support more than one input or output ascIOoutputMapIOindex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION " The I/O index for this row of the table. The range is 1 to ascIOmapMaxOutputs. 1.3.6.1.4.1.1206.4.2.1.13.6.1.1 S" ::= { ascIOoutputMapTableEntry 1 } ascIOoutputMapDeviceType OBJECT-TYPE SYNTAX INTEGER { unused (1), custom (2), fio (3), ts1 (4), biu (5), siu (6), aux (7) } ACCESS read-write STATUS mandatory DESCRIPTION " This object is an selects the device type for this row of the table. A value of unused (1) means that this row of the table is unused (all values of ascIOoutputMapIOindex up to or ascIOmapMaxOutputs may not be needed by every mapping). A custom type is a manufacturer defined device which also requires a ascIOoutputMapDevicePNN and a ascIOoutputMapDevicePtype to fully specify the device. Values > 7 are reserved for future device types. 1.3.6.1.4.1.1206.4.2.1.13.6.1.2 P" ::= { ascIOoutputMapTableEntry 2 } ascIOoutputMapDevicePNN OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION " The object is used to further define a device type when ascIOoutputMapDeviceType is custom (2). The value of this object will be the manufacturer's Private Node Number (PNN) as assigned by NEMA (1.3.6.1.4.1.1206.3.PNN). This is the same identifier used for ASC custom blocks. 1.3.6.1.4.1.1206.4.2.1.13.6.1.3 P" ::= { ascIOoutputMapTableEntry 3 } ascIOoutputMapDevicePtype OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " The object is used to further define a device type when ascIOoutputMapDeviceType is custom (2). The value of this object will identify a custom device type unique to the manufacturer specified by ascIOoutputMapDevicePNN. 1.3.6.1.4.1.1206.4.2.1.13.6.1.4 P" ::= { ascIOoutputMapTableEntry 4 } ascIOoutputMapDeviceAddr OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " An address for the device at this table row. The address is used for devices like BIUs and SIUs that require an address. The value should be zero if the address is not needed for this row. If the ascIOoutputMapDeviceType is biu (4), the address values are: 1 - Traffic Facilities BIU #1 2 - Traffic Facilities BIU #2 3 - Traffic Facilities BIU #3 4 - Traffic Facilities BIU #4 5-8 - reserved 9 - Detector BIU #1 10 - Detector BIU #2 11 - Detector BIU #3 12 - Detector BIU #4 13-16 - reserved Note that these values are the BIU SDLC address + 1. If the ascIOoutputMapDeviceType is siu (5), the address values are: 1 - reserved 2 - 14-pack output SIU position 1 3 - reserved 4 - 14-pack output SIU position 3 5 - 6-pack output SIU position 4 6 - 6-pack output SIU position 1 7 - 6-pack output SIU position 2 8 - 6-pack output SIU position 3 9 - reserved 10 - input SIU #1 11 - input SIU #2 12 - input SIU #3 13 - input SIU #4 14 - input SIU #5 15 - reserved Note that these values are the SIU SDLC address + 1. 1.3.6.1.4.1.1206.4.2.1.13.6.1.5 P" ::= { ascIOoutputMapTableEntry 5 } ascIOoutputMapDevicePin OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " An index for the I/O pin at this table row. The range for this value will depend upon the value of other objects in the row. The range for ascIOmapDeviceType: fio (3) pin range is AscIOmapFIOoutputs ts1 (4) pin range is AscIOmapTS1outputs biu (5) pin range is AscIOmapBIUoutputs siu (6) pin range is AscIOmapSIUoutputs aux (7) pin range is AscIOmapAUXoutputs The range for a custom device type will be determined by the manufacturer defining it. 1.3.6.1.4.1.1206.4.2.1.13.6.1.6 P" ::= { ascIOoutputMapTableEntry 6 } ascIOoutputMapFuncType OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION " This object selects the function type for this row of the table. A value of 0 references the standard output functions defined by AscIOoutputType and the ascIOoutputMapFunction. Any other value is a manufacturer's Private Node Number (PNN) as assigned by NEMA (1.3.6.1.4.1.1206.3.PNN). In this case the function is defined by the PNN (the manufacturer), ascIOoutputMapFuncPtype (which of the manufacturer's multiple function sets), and the ascIOoutputMapFunction. 1.3.6.1.4.1.1206.4.2.1.13.6.1.7 P" ::= { ascIOoutputMapTableEntry 7 } ascIOoutputMapFuncPtype OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " The object is used to further define a function type when ascIOoutputMapFuncType is not zero. The value of this object will identify a custom function type unique to the manufacturer specified by ascIOoutputMapDevicePNN. 1.3.6.1.4.1.1206.4.2.1.13.6.1.8 P" ::= { ascIOoutputMapTableEntry 8 } ascIOoutputMapFunction OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " This object specifies the function that is mapped to the I/O pin specified by this row. For example, if ascIOoutputMapFuncType is zero (standard) then the function could be any AscIOoutputType value such as channelGreen (6). 1.3.6.1.4.1.1206.4.2.1.13.6.1.9 P" ::= { ascIOoutputMapTableEntry 9 } ascIOoutputMapFuncIndex OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " An index for the function at this table row. For example, if ascIOoutputMapFuncType is zero (standard) and the ascIOoutputMapFunction is channelGreen (6), then this index will determine which channelGreen output it is (1 to maxChannels). 1.3.6.1.4.1.1206.4.2.1.13.6.1.11 P" ::= { ascIOoutputMapTableEntry 11 } ascIOoutputMapStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF AscIOoutputMapStatusTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table containing status for the current mapping for an ASC controller's outputs. static 1.3.6.1.4.1.1206.4.2.1.13.7" ::= { ascIOmapping 7 } ascIOoutputMapStatusTableEntry OBJECT-TYPE SYNTAX AscIOoutputMapStatusTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " This object defines a conceptual row in the ascIOoutputMapStatusTable. 1.3.6.1.4.1.1206.4.2.1.13.7.1" INDEX { ascIOmapNumber, ascIOoutputMapIOindex } ::= { ascIOoutputMapStatusTable 1 } AscIOoutputMapStatusTableEntry ::= SEQUENCE { ascIOoutputMapDevPinDescr OCTET STRING, -- description of output pin ascIOoutputMapDevPinStatus INTEGER } -- 0 or 1 for active ascIOoutputMapDevPinDescr OBJECT-TYPE SYNTAX OCTET STRING (SIZE (32)) ACCESS read-only STATUS mandatory DESCRIPTION " This object returns the name of the output pin, such as 'C1-39 Detector 2'. Since the physical pins are determined by the controller hardware, the value is read-only. 1.3.6.1.4.1.1206.4.2.1.13.7.1.1 S" ::= { ascIOoutputMapStatusTableEntry 1 } ascIOoutputMapDevPinStatus OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-only STATUS mandatory DESCRIPTION " This object returns the current status of an output pin: inactive/OFF (0) or active/ON (1). 1.3.6.1.4.1.1206.4.2.1.13.7.1.2" ::= { ascIOoutputMapStatusTableEntry 2 } ascIOmapDescriptionTable OBJECT-TYPE SYNTAX SEQUENCE OF AscIOmapDescriptionTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table containing mapping for an ASC Controller's inputs and outputs to functions. The number of I/O map tables is equal to the value of ascIOmaxMaps. Each table contains a row for each input the supported by the ASC. The total number of rows in the table is ascIOmapMaxInputs. Only one I/O input map may be active at any one time, and is selected by ascIOactiveMap. static 1.3.6.1.4.1.1206.4.2.1.13.8" ::= { ascIOmapping 8 } ascIOmapDescriptionTableEntry OBJECT-TYPE SYNTAX AscIOmapDescriptionTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " This object defines a conceptual set of rows in the ascIOinputMapTable and ascIOoutputMapTable tables corresponding to an ascIOmapNumber. 1.3.6.1.4.1.1206.4.2.1.13.8.1" INDEX { ascIOmapNumber } ::= { ascIOmapDescriptionTable 1 } AscIOmapDescriptionTableEntry ::= SEQUENCE { ascIOmapDescription OCTET STRING } -- description of table ascIOmapDescription OBJECT-TYPE SYNTAX OCTET STRING (SIZE (32)) ACCESS read-write STATUS mandatory DESCRIPTION " This object returns the name of the I/O map. There is only one name for the I/O map for each value of ascIOmapNumber. This map name corresponds to ascIOinputMapTable and ascIOoutputMapTable rows with the same ascIOmapNumber index. 1.3.6.1.4.1.1206.4.2.1.13.8.1.1 P" ::= { ascIOmapDescriptionTableEntry 1 } ascIOmapInputFunctions OBJECT IDENTIFIER ::= { ascIOmapping 9 } -- Enumeration for I/O mapping input functions AscIOinputType ::= INTEGER { unusedInput (1), -- an input pin that is unused, not mapped ioUsedAsOutput (2), -- an I/O pin that is being used as an output (SIU or BIU) logicInput (3), -- an input that is used only by the programmable logic addressBit (4), alarmInput (5), alternateSequence (6), autoFlashRequest (7), cabinetDoorOpen (8), callToNonActuated (9), clockUpdate (10), conflictMonitorStatus (11), cycleAdvance (12), dimmingEnable (13), externalStart (14), forceOffRing (15), freeRequest (16), hardwareControl (17), indicatorLampControl (18), inhibitMaxRing (19), intervalAdvance (20), localFlashSense (21), manualControlEnable (22), max2Ring (23), max3AllRings (24), max4AllRings (25), maxRecall (26), maxWalk (27), minRecall (28), mmuCmuFlashSense (29), modeSelectBit (30), offsetInput (31), omitRedClearRing (32), patternSelect (33), pedestrianDetector (34), pedestrianOmit (35), pedestrianRecycleRing (36), phaseHold (37), phaseOmit (38), preemptGateDown (39), preemptGateUp (40), preemptHealthy (41), preemptInput (42), preemptInputAdvanced (43), priorityCheckout (44), priorityRequest (45), redRestRing (46), specialFunctionInput (47), stopTimeAllRings (48), stopTimeRing (49), tbcOnline (50), testInput (51), timingPlanInput (52), vehicleDetector (53), vehicleDetectorFault (54), walkRestModifier (55) } ascIOmapMaxInputFunctions OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " This object contains the maximum number of I/O mapping input functions this ASC supports. This object indicates the number of rows in the ascIOmapInputFuncTable. The value of this object is equal to the number of AscIOinputType enumerations. 1.3.6.1.4.1.1206.4.2.1.13.9.1 S" ::= { ascIOmapInputFunctions 1 } ascIOmapInputFuncTable OBJECT-TYPE SYNTAX SEQUENCE OF AscIOmapInputFuncEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table referencing the ASC I/O mapping input functions. These are functions that may be assigned to the ASC inputs. The number of rows in this table is equal to ascIOmapMaxInputFunctions. The entries in this table correspond to the values of the AscIOinputType enumeration. static 1.3.6.1.4.1.1206.4.2.1.13.9.2" ::= { ascIOmapInputFunctions 2 } ascIOmapInputFuncEntry OBJECT-TYPE SYNTAX AscIOmapInputFuncEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " This object defines a conceptual row in the ascIOmapInputFuncTable. 1.3.6.1.4.1.1206.4.2.1.13.9.2.1" INDEX { ascIOinputIndex } ::= { ascIOmapInputFuncTable 1 } AscIOmapInputFuncEntry ::= SEQUENCE { ascIOinputIndex INTEGER, ascIOinputMaxFuncIndex INTEGER, ascIOinputFunctionName OCTET STRING } ascIOinputIndex OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " Indicates the row number of the entry in the ascIOmapInputFuncTable. The value of this object shall not exceed the ascIOmapMaxInputFunctions value. These indexes correspond to the values of the AscIOinputType enumeration. 1.3.6.1.4.1.1206.4.2.1.13.9.2.1.1 S" ::= { ascIOmapInputFuncEntry 1 } ascIOinputMaxFuncIndex OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " Some input functions support an array of inputs, this object indicates the maximum array index for this input function. 1.3.6.1.4.1.1206.4.2.1.13.9.2.1.2 S" ::= { ascIOmapInputFuncEntry 2 } ascIOinputFunctionName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (32)) ACCESS read-only STATUS mandatory DESCRIPTION " This object contains an ASCII string describing the input function. 1.3.6.1.4.1.1206.4.2.1.13.9.2.1.3 S" ::= { ascIOmapInputFuncEntry 3 } ascIOmapOutputFunctions OBJECT IDENTIFIER ::= { ascIOmapping 10 } -- Enumeration for I/O mapping output functions AscIOoutputType ::= INTEGER { unusedOutput (1), -- an output pin that is unused, not mapped ioUsedAsInput (2), -- an I/O pin that is being used as an input (SIU or BIU) logicOutput (3), -- an output function from the programmable logic advWarnGrn (4), advWarnRed (5), alarmOutput (6), automaticFlashStatus (7), channelGreen (8), channelRed (9), channelYellow (10), codedStatusBitA (11), codedStatusBitB (12), codedStatusBitC (13), detectorResetSlots (14), detectorReset (15), faultMonitor (16), flashingLogic (17), freeStatus (18), offsetOutput (19), phaseCheck (20), phaseNext (21), phaseOn (22), preemptActive (23), preemptActiveAdvanced (24), specialFunctionOutput (25), tbcAuxOutput (26), timingPlanOutput (27), voltageMonitor (28), watchdog (29) } ascIOmapMaxOutputFunctions OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " This object contains the maximum number of I/O mapping output functions this ASC supports. This object indicates the number of rows in the ascIOmapOutputFuncTable. The value of this object is equal to the number of AscIOoutputType enumerations. 1.3.6.1.4.1.1206.4.2.1.13.10.1 S" ::= { ascIOmapOutputFunctions 1 } ascIOmapOutputFuncTable OBJECT-TYPE SYNTAX SEQUENCE OF AscIOmapOutputFuncEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table referencing the ASC I/O mapping output functions. These are functions that may be assigned to the ASC outputs. The number of rows in this table is equal to ascIOmapMaxOutputFunctions. The entries in this table correspond to the values of the AscIOoutputType enumeration. static 1.3.6.1.4.1.1206.4.2.1.13.10.2" ::= { ascIOmapOutputFunctions 2 } ascIOmapOutputFuncEntry OBJECT-TYPE SYNTAX AscIOmapOutputFuncEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " This object defines a conceptual row in the ascIOmapOutputFuncTable. 1.3.6.1.4.1.1206.4.2.1.13.10.2.1" INDEX { ascIOoutputIndex } ::= { ascIOmapOutputFuncTable 1 } AscIOmapOutputFuncEntry ::= SEQUENCE { ascIOoutputIndex INTEGER, ascIOoutputMaxFuncIndex INTEGER, ascIOoutputFunctionName OCTET STRING } ascIOoutputIndex OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " Indicates the row number of the entry in the ascIOmapOutputFuncTable. The value of this object shall not exceed the ascIOmapMaxOutputFunctions value. These indexes correspond to the values of the AscIOoutputType enumeration. 1.3.6.1.4.1.1206.4.2.1.13.10.2.1.1 S" ::= { ascIOmapOutputFuncEntry 1 } ascIOoutputMaxFuncIndex OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " Some output functions support an array of outputs, this object indicates the maximum array index for this output function. 1.3.6.1.4.1.1206.4.2.1.13.10.2.1.2 S" ::= { ascIOmapOutputFuncEntry 2 } ascIOoutputFunctionName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (32)) ACCESS read-only STATUS mandatory DESCRIPTION " This object contains an ASCII string describing the output function. 1.3.6.1.4.1.1206.4.2.1.13.10.2.1.3 S" ::= { ascIOmapOutputFuncEntry 3 } ascIOmapFIO OBJECT IDENTIFIER ::= { ascIOmapping 11 } AscIOmapFIOinputs ::= INTEGER { -- Enumeration for 2070-2A FIO (170) inputs pinC1-39 (1), -- Detector 2 pinC1-40 (2), -- Detector 16 pinC1-41 (3), -- Detector 8 pinC1-42 (4), -- Detector 22 pinC1-43 (5), -- Detector 3 pinC1-44 (6), -- Detector 17 pinC1-45 (7), -- Detector 9 pinC1-46 (8), -- Detector 23 pinC1-47 (9), -- Detector 6 pinC1-48 (10), -- Detector 20 pinC1-49 (11), -- Detector 12 pinC1-50 (12), -- Detector 26 pinC1-51 (13), -- RR1 Preempt pinC1-52 (14), -- RR2 Preempt pinC1-53 (15), -- Manual Control pinC1-54 (16), -- Spare pinC1-55 (17), -- Detector 15 pinC1-56 (18), -- Detector 1 pinC1-57 (19), -- Detector 21 pinC1-58 (20), -- Detector 7 pinC1-59 (21), -- Detector 27 pinC1-60 (22), -- Detector 13 pinC1-61 (23), -- Detector 28 pinC1-62 (24), -- Detector 14 pinC1-63 (25), -- Detector 4 pinC1-64 (26), -- Detector 18 pinC1-65 (27), -- Detector 10 pinC1-66 (28), -- Detector 24 pinC1-67 (29), -- Ped Detector 1 pinC1-68 (30), -- Ped Detector 3 pinC1-69 (31), -- Ped Detector 2 pinC1-70 (32), -- Ped Detector 4 pinC1-71 (33), -- EVA Preempt pinC1-72 (34), -- EVB Preempt pinC1-73 (35), -- EVC Preempt pinC1-74 (36), -- EVD Preempt pinC1-75 (37), -- Spare pinC1-76 (38), -- Detector 5 pinC1-77 (39), -- Detector 19 pinC1-78 (40), -- Detector 11 pinC1-79 (41), -- Detector 25 pinC1-80 (42), -- Interval Advance pinC1-81 (43), -- Flash Sense pinC1-82 (44), -- Stop Time pinC11-10 (45), -- C11 inputs all spare pinC11-11 (46), pinC11-12 (47), pinC11-13 (48), pinC11-15 (49), pinC11-16 (50), pinC11-17 (51), pinC11-18 (52), pinC11-19 (53), pinC11-20 (54), pinC11-21 (55), pinC11-22 (56), pinC11-23 (57), pinC11-24 (58), pinC11-25 (59), pinC11-26 (60), pinC11-27 (61), pinC11-28 (62), pinC11-29 (63), pinC11-30 (64) } AscIOmapFIOoutputs ::= INTEGER { -- Enumeration for 2070-2A FIO (170) outputs pinC1-2 (1), -- Ped 4 red pinC1-3 (2), -- Ped 4 green pinC1-4 (3), -- Phase 4 red pinC1-5 (4), -- Phase 4 yellow pinC1-6 (5), -- Phase 4 green pinC1-7 (6), -- Phase 3 red pinC1-8 (7), -- Phase 3 yellow pinC1-9 (8), -- Phase 3 green pinC1-10 (9), -- Ped 2 red pinC1-11 (10), -- Ped 2 green pinC1-12 (11), -- Phase 2 red pinC1-13 (12), -- Phase 2 yellow pinC1-15 (13), -- Phase 2 green pinC1-16 (14), -- Phase 1 red pinC1-17 (15), -- Phase 1 yellow pinC1-18 (16), -- Phase 1 green pinC1-19 (17), -- Ped 8 red pinC1-20 (18), -- Ped 8 green pinC1-21 (19), -- Phase 8 red pinC1-22 (20), -- Phase 8 yellow pinC1-23 (21), -- Phase 8 green pinC1-24 (22), -- Phase 7 red pinC1-25 (23), -- Phase 7 yellow pinC1-26 (24), -- Phase 7 green pinC1-27 (25), -- Ped 6 red pinC1-28 (26), -- Ped 6 green pinC1-29 (27), -- Phase 6 red pinC1-30 (28), -- Phase 6 yellow pinC1-31 (29), -- Phase 6 green pinC1-32 (30), -- Phase 5 red pinC1-33 (31), -- Phase 5 yellow pinC1-34 (32), -- Phase 5 green pinC1-35 (33), -- Ped 2 yellow pinC1-36 (34), -- Ped 6 yellow pinC1-37 (35), -- Ped 4 yellow pinC1-38 (36), -- Ped 8 yellow pinC1-83 (37), -- Spare pinC1-84 (38), -- Spare pinC1-85 (39), -- Overlap D red pinC1-86 (40), -- Overlap D yellow pinC1-87 (41), -- Overlap D green pinC1-88 (42), -- Overlap C red pinC1-89 (43), -- Overlap C yellow pinC1-90 (44), -- Overlap C green pinC1-91 (45), -- Spare pinC1-93 (46), -- Spare pinC1-94 (47), -- Overlap B red pinC1-95 (48), -- Overlap B yellow pinC1-96 (49), -- Overlap B green pinC1-97 (50), -- Overlap A red pinC1-98 (51), -- Overlap A yellow pinC1-99 (52), -- Overlap A green pinC1-100 (53), -- Spare pinC1-101 (54), -- Flash status pinC1-102 (55), -- Detector reset pinC1-103 (56), -- Watchdog pinC11-1 (57), -- all C11 outputs are spare pinC11-2 (58), pinC11-3 (59), pinC11-4 (60), pinC11-5 (61), pinC11-6 (62), pinC11-7 (63), pinC11-8 (64) } ascIOmapTS1 OBJECT IDENTIFIER ::= { ascIOmapping 12 } AscIOmapTS1inputs ::= INTEGER { -- Enumeration for type 2070-8 NEMA TS1 inputs pinA-f (1), -- Vehicle Detector 1 pinA-g (2), -- Ped Detector 1 pinA-h (3), -- Hold 1 pinA-i (4), -- Force Off Ring 1 pinA-j (5), -- Min Recall pinA-k (6), -- Manual Control pinA-m (7), -- CNA 1 pinA-n (8), -- Test A pinA-q (9), -- Mode Bit A pinA-v (10), -- Ped Omit 2 pinA-w (11), -- Omit Red Ring 1 pinA-x (12), -- Red Rest Ring 1 pinA-y (13), -- Mode Bit B pinA-z (14), -- CNA 2 pinA-K (15), -- Vehicle Detector 2 pinA-L (16), -- Ped Detector 2 pinA-M (17), -- Hold 2 pinA-N (18), -- Stop Time Ring 1 pinA-P (19), -- Inhibit Max Ring 1 pinA-R (20), -- External Start pinA-S (21), -- Interval Advance pinA-T (22), -- Lamp Control pinA-AA (23), -- Test B pinA-BB (24), -- Walk Rest Modifier pinA-EE (25), -- Ped Omit 1 pinA-FF (26), -- Ped Recycle Ring 1 pinA-GG (27), -- Max 2 Ring 1 pinA-HH (28), -- Mode Bit C pinB-g (29), -- Phase Omit 4 pinB-h (30), -- Hold 4 pinB-i (31), -- Hold 3 pinB-j (32), -- Ped Omit 3 pinB-k (33), -- Ped Omit 6 pinB-m (34), -- Ped Omit 7 pinB-n (35), -- Ped Omit 8 pinB-v (36), -- Spare pinB-x (37), -- Ped Omit 4 pinB-z (38), -- Max 2 Ring 2 pinB-B (39), -- Spare pinB-L (40), -- Vehicle Detector 4 pinB-M (41), -- Ped Detector 4 pinB-N (42), -- Vehicle Detector 3 pinB-P (43), -- Ped Detector 3 pinB-R (44), -- Phase Omit 3 pinB-S (45), -- Phase Omit 2 pinB-T (46), -- Ped Omit 5 pinB-U (47), -- Phase Omit 1 pinB-V (48), -- Ped RECY R2 pinB-W (49), -- Spare pinB-X (50), -- Spare pinC-a (51), -- Inhibit Max Ring 2 pinC-b (52), -- Ttest C pinC-m (53), -- Hold 5 pinC-n (54), -- Phase Omit 5 pinC-p (55), -- Hold 6 pinC-q (56), -- Phase Omit 6 pinC-r (57), -- Phase Omit 7 pinC-s (58), -- Phase Omit 8 pinC-t (59), -- Vehicle Detector 8 pinC-u (60), -- Red Rest Ring 2 pinC-v (61), -- Omit Red Ring 2 pinC-P (62), -- Vehicle Detector 5 pinC-R (63), -- Ped Detector 5 pinC-S (64), -- Vehicle Detector 6 pinC-T (65), -- Ped Detector 6 pinC-U (66), -- Ped Detector 7 pinC-V (67), -- Vehicle Detector 7 pinC-W (68), -- Ped Detector 8 pinC-X (69), -- Hold 8 pinC-Y (70), -- Force Off Ring 2 pinC-Z (71), -- Stop Time Ring 2 pinC-EE (72), -- Hold 7 pinD-a (73), -- Spare pinD-b (74), -- Alarm 1 pinD-c (75), -- Alarm 2 pinD-d (76), -- Alarm 3 pinD-e (77), -- Alarm 4 pinD-f (78), -- Alarm 5 pinD-g (79), -- Flash In pinD-h (80), -- Conflict Monitor Status pinD-i (81), -- Door Open pinD-j (82), -- Special Function 1 pinD-k (83), -- Special Function 2 pinD-m (84), -- Special Function 3 pinD-n (85), -- Special Function 4 pinD-p (86), -- Special Function 5 pinD-q (87), -- Special Function 6 pinD-r (88), -- Special Function 7 pinD-s (89), -- Special Function 8 pinD-t (90), -- Preempt 1 pinD-u (91), -- Preempt 2 pinD-v (92), -- Preempt 3 pinD-w (93), -- Preempt 4 pinD-x (94), -- Preempt 5 pinD-y (95), -- Preempt 6 pinD-A (96), -- Vehicle Detector 9 pinD-B (97), -- Vehicle Detector 10 pinD-C (98), -- Vehicle Detector 11 pinD-D (99), -- Vehicle Detector 12 pinD-E (100), -- Vehicle Detector 13 pinD-F (101), -- Vehicle Detector 14 pinD-G (102), -- Vehicle Detector 15 pinD-H (103), -- Vehicle Detector 16 pinD-J (104), -- Vehicle Detector 17 pinD-K (105), -- Vehicle Detector 18 pinD-L (106), -- Vehicle Detector 19 pinD-M (107), -- Vehicle Detector 20 pinD-N (108), -- Vehicle Detector 21 pinD-P (109), -- Vehicle Detector 22 pinD-R (110), -- Vehicle Detector 23 pinD-S (111), -- Vehicle Detector 24 pinD-T (112), -- Clock Update pinD-U (113), -- Hardware Control pinD-V (114), -- Cycle Advance pinD-W (115), -- Max 3 Select pinD-X (116), -- Max 4 Select pinD-Y (117), -- Free pinD-Z (118), -- Spare pinD-KK (119), -- Spare pinD-MM (120) } -- Spare AscIOmapTS1outputs ::= INTEGER { -- Enumeration for 2070-8 NEMA TS1 outputs pinA-a (1), -- Ped 1 Yellow pinA-b (2), -- Phase 2 Yellow pinA-c (3), -- Phase 2 Green pinA-d (4), -- Phase Check 2 pinA-e (5), -- Phase On 2 pinA-r (6), -- Status B Ring 1 pinA-s (7), -- Phase 1 Green pinA-t (8), -- Ped 1 Green pinA-u (9), -- Phase Check 1 pinA-A (10), -- Fault Monitor pinA-C (11), -- Voltage Monitor pinA-D (12), -- Phase 1 Red pinA-E (13), -- Ped 1 Red pinA-F (14), -- Phase 2 Red pinA-G (15), -- Ped 2 Red pinA-H (16), -- Ped 2 Yellow pinA-J (17), -- Ped 2 Green pinA-X (18), -- Flashing Logic pinA-Y (19), -- Status C Ring 1 pinA-Z (20), -- Phase 1 Yellow pinA-CC (21), -- Status A Ring 1 pinA-DD (22), -- Phase ON 1 pinB-a (23), -- Ped 3 Red pinB-b (24), -- Phase 4 Green pinB-c (25), -- Phase 4 Yellow pinB-d (26), -- Ped 4 Green pinB-e (27), -- Phase On 4 pinB-f (28), -- Phase Next 4 pinB-p (29), -- Overlap A Yellow pinB-q (30), -- Overlap A Red pinB-r (31), -- Phase Check 3 pinB-s (32), -- Phase On 3 pinB-t (33), -- Phase Next 3 pinB-u (34), -- Overlap D Red pinB-w (35), -- Overlap D Green pinB-A (36), -- Phase Next 1 pinB-C (37), -- Phase Next 2 pinB-D (38), -- Phase 3 Green pinB-E (39), -- Phase 3 Yellow pinB-F (40), -- Phase 3 Red pinB-G (41), -- Phase 4 Red pinB-H (42), -- Ped 4 Yellow pinB-J (43), -- Ped 4 Red pinB-K (44), -- Phase Check 4 pinB-Y (45), -- Ped 3 Green pinB-Z (46), -- Ped 3 Yellow pinB-AA (47), -- Overlap A Green pinB-BB (48), -- Overlap B Yellow pinB-CC (49), -- Overlap B Red pinB-DD (50), -- Overlap C Red pinB-EE (51), -- Overlap D Yellow pinB-FF (52), -- Overlap C Green pinB-GG (53), -- Overlap B Green pinB-HH (54), -- Overlap C Yellow pinC-c (55), -- Status C Ring 2 pinC-d (56), -- Ped 8 Green pinC-e (57), -- Phase 8 Yellow pinC-f (58), -- Phase 7 Green pinC-g (59), -- Phase 6 Green pinC-h (60), -- Phase 6 Yellow pinC-i (61), -- Phase 5 Green pinC-j (62), -- Ped 5 Green pinC-k (63), -- Phase Check 5 pinC-w (64), -- Ped 8 Yellow pinC-x (65), -- Phase 8 Green pinC-y (66), -- Ped 7 Red pinC-z (67), -- Ped 6 Red pinC-A (68), -- Status A Ring 2 pinC-B (69), -- Status B Ring 2 pinC-C (70), -- Ped 8 Red pinC-D (71), -- Phase 8 Red pinC-E (72), -- Phase 7 Yellow pinC-F (73), -- Phase 7 Red pinC-G (74), -- Phase 6 Red pinC-H (75), -- Phase 5 Red pinC-J (76), -- Phase 5 Yellow pinC-K (77), -- Ped 5 Yellow pinC-L (78), -- Ped 5 Red pinC-M (79), -- Phase Next 5 pinC-N (80), -- Phase On 5 pinC-AA (81), -- Ped 6 Yellow pinC-BB (82), -- Phase Check 6 pinC-CC (83), -- Phase ON 6 pinC-DD (84), -- Phase Next 6 pinC-FF (85), -- Phase Check 8 pinC-GG (86), -- Phase On 8 pinC-HH (87), -- Phase Next 8 pinC-JJ (88), -- Ped 7 Green pinC-KK (89), -- Ped 7 Yellow pinC-LL (90), -- Ped 6 Green pinC-MM (91), -- Phase Check 7 pinC-NN (92), -- Phase On 7 pinC-PP (93), -- Phase Next 7 pinD-z (94), -- Alarm 1 pinD-AA (95), -- Alarm 2 pinD-BB (96), -- Special Function 1 pinD-CC (97), -- Special Function 2 pinD-DD (98), -- Special Function 3 pinD-EE (99), -- Special Function 4 pinD-FF (100), -- Special Function 5 pinD-GG (101), -- Special Function 6 pinD-HH (102), -- Special Function 7 pinD-JJ (103), -- Special Function 8 pinD-LL (104) } -- Detector Reset ascIOmapBIU OBJECT IDENTIFIER ::= { ascIOmapping 13 } AscIOmapBIUinputs ::= INTEGER { -- Enumeration for NEMA TS2 BIU inputs (for each BIU) biuInputIO1 (1), biuInputIO2 (2), biuInputIO3 (3), biuInputIO4 (4), biuInputIO5 (5), biuInputIO6 (6), biuInputIO7 (7), biuInputIO8 (8), biuInputIO9 (9), biuInputIO10 (10), biuInputIO11 (11), biuInputIO12 (12), biuInputIO13 (13), biuInputIO14 (14), biuInputIO15 (15), biuInputIO16 (16), biuInputIO17 (17), biuInputIO18 (18), biuInputIO19 (19), biuInputIO20 (20), biuInputIO21 (21), biuInputIO22 (22), biuInputIO23 (23), biuInputIO24 (24), biuInputIN1 (25), biuInputIN2 (26), biuInputIN3 (27), biuInputIN4 (28), biuInputIN5 (29), biuInputIN6 (30), biuInputIN7 (31), biuInputIN8 (32), biuInputOPT1 (33), biuInputOPT2 (34), biuInputOPT3 (35), biuInputOPT4 (36) } AscIOmapBIUoutputs ::= INTEGER { -- Enumeration for NEMA TS2 BIU outputs (for each BIU) biuOutputO1 (1), biuOutputO2 (2), biuOutputO3 (3), biuOutputO4 (4), biuOutputO5 (5), biuOutputO6 (6), biuOutputO7 (7), biuOutputO8 (8), biuOutputO9 (9), biuOutputO10 (10), biuOutputO11 (11), biuOutputO12 (12), biuOutputO13 (13), biuOutputO14 (14), biuOutputO15 (15), biuOutputIO1 (16), biuOutputIO2 (17), biuOutputIO3 (18), biuOutputIO4 (19), biuOutputIO5 (20), biuOutputIO6 (21), biuOutputIO7 (22), biuOutputIO8 (23), biuOutputIO9 (24), biuOutputIO10 (25), biuOutputIO11 (26), biuOutputIO12 (27), biuOutputIO13 (28), biuOutputIO14 (29), biuOutputIO15 (30), biuOutputIO16 (31), biuOutputIO17 (32), biuOutputIO18 (33), biuOutputIO19 (34), biuOutputIO20 (35), biuOutputIO21 (36), biuOutputIO22 (37), biuOutputIO23 (38), biuOutputIO24 (39) } ascIOmapSIU OBJECT IDENTIFIER ::= { ascIOmapping 14 } AscIOmapSIUinputs ::= INTEGER { -- Enumeration for ITS Cabinet SIU inputs (for each SIU) siuInputIO0 (1), siuInputIO1 (2), siuInputIO2 (3), siuInputIO3 (4), siuInputIO4 (5), siuInputIO5 (6), siuInputIO6 (7), siuInputIO7 (8), siuInputIO8 (9), siuInputIO9 (10), siuInputIO10 (11), siuInputIO11 (12), siuInputIO12 (13), siuInputIO13 (14), siuInputIO14 (15), siuInputIO15 (16), siuInputIO16 (17), siuInputIO17 (18), siuInputIO18 (19), siuInputIO19 (20), siuInputIO20 (21), siuInputIO21 (22), siuInputIO22 (23), siuInputIO23 (24), siuInputIO24 (25), siuInputIO25 (26), siuInputIO26 (27), siuInputIO27 (28), siuInputIO28 (29), siuInputIO29 (30), siuInputIO30 (31), siuInputIO31 (32), siuInputIO32 (33), siuInputIO33 (34), siuInputIO34 (35), siuInputIO35 (36), siuInputIO36 (37), siuInputIO37 (38), siuInputIO38 (39), siuInputIO39 (40), siuInputIO40 (41), siuInputIO41 (42), siuInputIO42 (43), siuInputIO43 (44), siuInputIO44 (45), siuInputIO45 (46), siuInputIO46 (47), siuInputIO47 (48), siuInputIO48 (49), siuInputIO49 (50), siuInputIO50 (51), siuInputIO51 (52), siuInputIO52 (53), siuInputIO53 (54), siuInputOPT1 (55), siuInputOPT2 (56), siuInputOPT3 (57), siuInputOPT4 (58) } AscIOmapSIUoutputs ::= INTEGER { -- Enumeration for ITS Cabinet SIU outputs (for each SIU) siuOutputIO0 (1), siuOutputIO1 (2), siuOutputIO2 (3), siuOutputIO3 (4), siuOutputIO4 (5), siuOutputIO5 (6), siuOutputIO6 (7), siuOutputIO7 (8), siuOutputIO8 (9), siuOutputIO9 (10), siuOutputIO10 (11), siuOutputIO11 (12), siuOutputIO12 (13), siuOutputIO13 (14), siuOutputIO14 (15), siuOutputIO15 (16), siuOutputIO16 (17), siuOutputIO17 (18), siuOutputIO18 (19), siuOutputIO19 (20), siuOutputIO20 (21), siuOutputIO21 (22), siuOutputIO22 (23), siuOutputIO23 (24), siuOutputIO24 (25), siuOutputIO25 (26), siuOutputIO26 (27), siuOutputIO27 (28), siuOutputIO28 (29), siuOutputIO29 (30), siuOutputIO30 (31), siuOutputIO31 (32), siuOutputIO32 (33), siuOutputIO33 (34), siuOutputIO34 (35), siuOutputIO35 (36), siuOutputIO36 (37), siuOutputIO37 (38), siuOutputIO38 (39), siuOutputIO39 (40), siuOutputIO40 (41), siuOutputIO41 (42), siuOutputIO42 (43), siuOutputIO43 (44), siuOutputIO44 (45), siuOutputIO45 (46), siuOutputIO46 (47), siuOutputIO47 (48), siuOutputIO48 (49), siuOutputIO49 (50), siuOutputIO50 (51), siuOutputIO51 (52), siuOutputIO52 (53), siuOutputIO53 (54) } ascIOmapAUX OBJECT IDENTIFIER ::= { ascIOmapping 15 } AscIOmapAUXinputs ::= INTEGER { -- Enumeration for AUX inputs auxInputFPSwitch (1), -- front panel AUX switch auxInputIO0 (2), auxInputIO1 (3), auxInputIO2 (4), auxInputIO3 (5), auxInputIO4 (6), auxInputIO5 (7), auxInputIO6 (8), auxInputIO7 (9) } AscIOmapAUXoutputs ::= INTEGER { -- Enumeration for AUX outputs auxOutputIO0 (1), auxOutputIO1 (2), auxOutputIO2 (3), auxOutputIO3 (4), auxOutputIO4 (5), auxOutputIO5 (6), auxOutputIO6 (7), auxOutputIO7 (8) } siuport1 OBJECT IDENTIFIER ::= { asc 14 } -- This object is an identifier used to group all objects for -- support of ITS Cabinet V1 Section 4.7.14.7.1 SIU Port 1 Operation. maxSIUPort1Addresses OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The Maximum Number of SIU Port 1 addresses this Actuated Controller Unit supports. This object indicates the maximum rows which shall appear in the siuPort1Table object. 1.3.6.1.4.1.1206.4.2.1.14.1 S address" ::= { siuport1 1 } siuport1Table OBJECT-TYPE SYNTAX SEQUENCE OF SIUPort1Entry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table containing Actuated Controller Unit port 1 parameters. The number of rows in this table is equal to maxSIUPort1Addresses object. Address 255 is reserved for the Broadcast All address. static 1.3.6.1.4.1.1206.4.2.1.14.2" ::= { siuport1 2 } siuport1Entry OBJECT-TYPE SYNTAX SIUPort1Entry ACCESS not-accessible STATUS mandatory DESCRIPTION " This object defines a conceptual row in the SIU Port 1 Table. 1.3.6.1.4.1.1206.4.2.1.14.2.1" INDEX { siuport1Number } ::= { siuport1Table 1 } SIUPort1Entry ::= SEQUENCE { siuport1Number INTEGER, siuport1DevicePresent INTEGER, siuport1Status INTEGER} siuport1Number OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The (SIU Port 1 address plus one) for objects in this row. This value shall not exceed the maxSIUPort1Addresses object value. 1.3.6.1.4.1.1206.4.2.1.14.2.1.1 S address" ::= { siuport1Entry 1 } siuport1DevicePresent OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-write STATUS mandatory DESCRIPTION " This object is used to program the CU as to the presence or absence of a device for this SIU Port 1 address. The CU shall transmit Command Frames only to those devices that are present as determined by this programming. True (one) - the device is present. False (zero) - the device is not present. 1.3.6.1.4.1.1206.4.2.1.14.2.1.2 C" REFERENCE "ITS Cabinet V1 Section 4.7.14.7.1" ::= { siuport1Entry 2 } siuport1Status OBJECT-TYPE SYNTAX INTEGER { other (1), online (2), responseFault (3)} ACCESS read-only STATUS mandatory DESCRIPTION " This object indicates the communications status with the associated device: other: This indicates that some other communications fault has been detected. online: This indicates that at least five of the most recent 10 response transfers were received correctly. responseFault: This indicates that more than 5 of the most recent 10 response transfers were received incorrectly. 1.3.6.1.4.1.1206.4.2.1.14.2.1.3 S" ::= { siuport1Entry 3 } ascRsuPort OBJECT IDENTIFIER ::= { asc 15 } -- This defines a node to configure communications for a connected vehicle environment. rsuCommPort OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " This object defines the ifIndex for a row in the ifTable and the commPortTable that identifies a communications port that is used to exchange data with an RSU. A value of 0 indicates that there is no RSU port or RSU communications is disabled. The value shall not exceed the object maxCommPorts value. 1.3.6.1.4.1.1206.4.2.1.15.1 P" ::= { ascRsuPort 1 } maxRsuPorts OBJECT-TYPE SYNTAX INTEGER(0..16) ACCESS read-only STATUS mandatory DESCRIPTION " This object contains the maximum number of logical RSU Ports this CU supports for a channel. This object indicates the maximum rows which shall appear in the rsuPortTable object. 1.3.6.1.4.1.1206.4.2.1.15.2 S port" ::= { ascRsuPort 2 } rsuPortTable OBJECT-TYPE SYNTAX SEQUENCE OF RsuPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " This table contains configuration and status information for logical ports to communicate with RSUs. The number of rows in this table is equal to the maxRsuPorts object. static 1.3.6.1.4.1.1206.4.2.1.15.3" ::= { ascRsuPort 3 } rsuPortEntry OBJECT-TYPE SYNTAX RsuPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " The configuration and status of a logical RSU port. 1.3.6.1.4.1.1206.4.2.1.15.3.1" INDEX { rsuPortIndex } ::= { rsuPortTable 1 } RsuPortEntry ::= SEQUENCE { rsuPortIndex INTEGER, rsuPortPointer INTEGER, rsuPortName DisplayString, rsuPortPollingPeriod INTEGER, rsuPortWatchdogTime INTEGER, rsuPortWatchdogTimer INTEGER, rsuPortNumber INTEGER } rsuPortIndex OBJECT-TYPE SYNTAX INTEGER (1..16) ACCESS read-only STATUS mandatory DESCRIPTION " This object provides the index into the RSU port table. This value shall not exceed the maxRsuPorts object value. 1.3.6.1.4.1.1206.4.2.1.15.3.1.1 S" ::= { rsuPortEntry 1 } rsuPortPointer OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION " This value is equal to the logicalNameTranslationIndex for the logical name translation table entry where logicalNameTranslationName holds the logical name and logicalNameTranslationNetworkAddress holds the IP address of the RSU port. This value shall not exceed the logicalNameTranslationTableMaxEntries object value. 1.3.6.1.4.1.1206.4.2.1.15.3.1.2 P" ::= { rsuPortEntry 2 } rsuPortName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-write STATUS mandatory DESCRIPTION " A textual string describing the RSU or the location of the RSU. 1.3.6.1.4.1.1206.4.2.1.15.3.1.3 P" ::= { rsuPortEntry 3 } rsuPortPollingPeriod OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION " This object defines the interval, in milliseconds, between polls on the port identified by this row. This object assumes that the CU behaves as the manager when exchanging data with an RSU. A value of 0 indicates that polling is disabled. This object is not used if the CU is the SNMP agent between the ASC - RSU interface. 1.3.6.1.4.1.1206.4.2.1.15.3.1.4 P milliseconds" ::= { rsuPortEntry 4 } rsuPortWatchdogTime OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION " This object defines the maximum time duration, in milliseconds, allowable without activity on the port identified by this row. If the amount of time that activity was last detected exceeds this value, then a RSU watchdog no activity fault alarm is SET. A value of 0 disables the RSU Watchdog no activity fault alarm. This object is not used if rsuPortPollingPeriod is 0. 1.3.6.1.4.1.1206.4.2.1.15.3.1.5 P milliseconds" ::= { rsuPortEntry 5 } rsuPortWatchdogTimer OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION " This object defines the watchdog time, in milliseconds, which is the amount of time since activity was last detected on the port identified by this row (rsuPortIndex). Activity is defined as any valid data object received on the port. If this object exceeds rsuPortWatchdogTime, then a RSU watchdog no activity fault is reported. This object is not used if rsuPortPollingPeriod is 0. 1.3.6.1.4.1.1206.4.2.1.15.3.1.6 S milliseconds" ::= { rsuPortEntry 6 } rsuPortNumber OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION " This object defines the port number for transmissions. An object value of 0 indicates the port is disabled. 1.3.6.1.4.1.1206.4.2.1.15.3.1.7 P" DEFVAL { 0 } ::= { rsuPortEntry 7 } ascSpat OBJECT IDENTIFIER ::= { asc 16 } -- This defines a node to support signal phase and timing objects for a connected vehicle environment. spatTimestamp OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0 | 5)) ACCESS read-only STATUS mandatory DESCRIPTION " A 5-byte value representing the time of day the SPaT data is generated by the CU. The 5 bytes are: Byte 1: hours (0..23) Byte 2: minutes (0..59) Byte 3: seconds (0..60). 60 is used to support leap seconds. Byte 4-5: milliseconds (0..999) 1.3.6.1.4.1.1206.4.2.1.16.1 S" DEFVAL { "" } ::= { ascSpat 1 } spatEnabledLanesCommand OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS deprecated DESCRIPTION " To support SAE J2735, this object is used to establish the Enabled lanes for the device to be broadcast in a SPaT message. Each octet within the octet string contains the mapLaneIndex(s) (binary value) in the MAP plan data configuration that is broadcast to be ACTIVE. An octet string of SIZE(1) with a value of 0xFF indicates that the device shall cancel this command and shall revert back to the Enabled lanes defined by enabledlaneconcurrency for the current time base action. Otherwise, the Enabled lanes defined is this command shall override the Enabled lanes defined in enabledlaneconcurrency. If the commanded set if Enabled lanes is valid, the new set of Enabled lanes will be broadcast at the top of the next cycle. If an unsupported / invalid set of Enabled lanes is called, then the spatPortStatus object shall be SET to enabledLanesError(5) for all valid entries in the spatPortTable. 1.3.6.1.4.1.1206.4.2.1.16.2 P" REFERENCE "SAE J2735 DF_EnabledLaneList" ::= { ascSpat 2 } spatEnabledLanesConcurrencyTable OBJECT-TYPE SYNTAX SEQUENCE OF SpatEnabledLanesConcurrencyEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table containing the revocable lanes that are allowed to be concurrently ACTIVE. The number of rows in this table is equal to the maxEnabledLanesConcurrency object. static 1.3.6.1.4.1.1206.4.2.1.16.3" ::= { ascSpat 3 } spatEnabledLanesConcurrencyEntry OBJECT-TYPE SYNTAX SpatEnabledLanesConcurrencyEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " The allowable lanes that may be ACTIVE concurrently. 1.3.6.1.4.1.1206.4.2.1.16.3.1" INDEX { enabledLaneIndex } ::= { spatEnabledLanesConcurrencyTable 1 } SpatEnabledLanesConcurrencyEntry::= SEQUENCE { enabledLaneIndex INTEGER, enabledLaneConcurrency OCTET STRING } enabledLaneIndex OBJECT-TYPE SYNTAX INTEGER (1..254) ACCESS read-only STATUS mandatory DESCRIPTION " The number for objects in this row. This value shall not exceed the maxEnabledLanesConcurrency object value. 1.3.6.1.4.1.1206.4.2.1.16.3.1.1 S" ::= { spatEnabledLanesConcurrencyEntry 1 } enabledLaneConcurrency OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION " Each octet contains a revocable lane identifier that may be ACTIVE concurrently. The value could be a single octet. This object indicates a set of revocable lanes that may be simultaneously enabled. 1.3.6.1.4.1.1206.4.2.1.16.3.1.2 P" ::= { spatEnabledLanesConcurrencyEntry 2 } spatOptions OBJECT-TYPE SYNTAX INTEGER(0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Optional SPaT functions ( 0 = False/Disabled, 1 = True/Enabled) Bit 3 - 7: Reserved Bit 2: MAP Validity. Indicates if the MAP data message broadcasted by the RSU is valid (1) or invalid (0). When this bit is one, the MAP Message broadcasted by the CV Roadside Process is considered valid. When this bit is 0, then the MAP message broadcasted by the RSU is considered invalid and should not be used except for test purposes. Bit 1: SPaT Validity. Indicates if the SPaT data for this CU is valid (1) or invalid (0). When this bit is one, the SPaT data provided by the controller is considered valid. When this bit is 0, then the SPaT data provided by the controller is considered invalid and should not be used except for test purposes. Bit 0: Enabled SPaT. Provides a means to enable the CU to provide SPaT data to a management station or a RSU. 1.3.6.1.4.1.1206.4.2.1.16.4 P" ::= { ascSpat 4 } spatPortTable OBJECT-TYPE SYNTAX SEQUENCE OF SpatPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " This table contains configuration and status information for exchanging SPaT information with RSUs. The number of rows in this table is equal to the maxRsuPorts object. static 1.3.6.1.4.1.1206.4.2.1.16.5" ::= { ascSpat 5 } spatPortEntry OBJECT-TYPE SYNTAX SpatPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " The configuration and status to exchange SPaT data with a logical RSU port. 1.3.6.1.4.1.1206.4.2.1.16.5.1" INDEX { rsuPortIndex } ::= { spatPortTable 1 } SpatPortEntry ::= SEQUENCE { spatPortOptions INTEGER, spatPortStatus INTEGER, spatPortMapActivationCode MapActivationCode } spatPortOptions OBJECT-TYPE SYNTAX INTEGER(0..255) ACCESS read-write STATUS mandatory DESCRIPTION " Optional SPaT functions for this SPaT port(0 = False/Disabled, 1 = True/Enabled) Bit 3 - 7: Reserved Bit 2: MAP Validity. Indicates if the MAP data message broadcasted by the RSU on this RSU port is valid (1) or invalid (0). When this bit is one, the MAP Message broadcasted by the CV Roadside Process is considered valid. When this bit is 0, then the MAP message broadcasted by the RSU is considered invalid and should not be used except for test purposes. Bit 1: SPaT Validity. Indicates if the SPaT data on this RSU port is valid (1) or invalid (0). When this bit is one, the SPaT data provided by the controller is considered valid. When this bit is 0, then the SPaT data provided by the controller is considered invalid and should not be used except for test purposes. Bit 0: Enabled SPaT. Provides a means to enable the CU to exchange SPaT data on this RSU port. 1.3.6.1.4.1.1206.4.2.1.16.5.1.1 P" ::= { spatPortEntry 1 } spatPortStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), normal(3), mapError(4), enabledLanesError(5) } ACCESS read-only STATUS mandatory DESCRIPTION " The status for exchanging SPaT data for this RSU port. other: A status not defined by this standard. disabled: The capability to provide SPaT data is disabled. normal: The CU is providing SPaT data. mapError: The CU has stopped providing SPaT data because of an inconsistency in the spatPortMapActivationCode. enabledLanesError: The CU has stopped providing SPaT data because of a consistency error with the SPaT enabled lanes concurrency table (spatEnabledLanesConcurrencyTable). Note: Bit 13 in the spatStatus2 is also enabled. 1.3.6.1.4.1.1206.4.2.1.16.5.1.2 S" ::= { spatPortEntry 2 } spatPortMapActivationCode OBJECT-TYPE SYNTAX MapActivationCode ACCESS read-write STATUS mandatory DESCRIPTION " Represents the current mapActivationCode for this RSU port that the signal patterns on the CU are programmed for. The spatPortMapActivationCode value in this row should match the mapActivatePlan value for the RSU on this RSU port. This object allows the CU to compare and confirm that the signal phase and timing data matches the MAP data that may be broadcast by the RSU. 1.3.6.1.4.1.1206.4.2.1.16.5.1.3 P" ::= { spatPortEntry 3 } ascCurrentTick OBJECT-TYPE SYNTAX INTEGER (0..36000) ACCESS read-only STATUS deprecated DESCRIPTION " This object is a counter of the number of elapsed ASC traffic processing ticks. The value is incremented by 1 (decisecond) every time the ASC completes its tenth of a second processing and commits a new set of IO signal states. The object is represented as a rolling counter with a zero representing the top of the hour. If the counter were to be incremented beyond 35999 the value shall roll over back to 0. Values equal to or greater than 36000 are reserved. 1.3.6.1.4.1.1206.4.2.1.16.6 S tenth of a second" ::= { ascSpat 6 } ascCurrentTickMsOffset OBJECT-TYPE SYNTAX INTEGER (0..99) ACCESS read-only STATUS mandatory DESCRIPTION " This object reflects the elapsed milliseconds within the current ASC traffic processing tick at the moment this object was encoded and transmitted. The main purpose of this object is to provide millisecond accuracy when calculating the future time points defined in the signalStatusTable2. It is important to note that this object is intended to be used with a remote NTCIP manager polling or issuing GET requests on the ascCurrentTick2 object. If ascCurrentTick2 is pushed, SET, or otherwise event driven then the ascCurrentTickMsOffset will not be useful as the ascCurrentTick2 object will be transmitted exactly on tick boundaries (ie always when ascCurrentTickMsOffset is 0). If an NTCIP manager is polling the ASC for the tick count it is recommended that the manager request both ascCurrentTick2 and ascCurrentMsTickOffset in a combined atomic varbind PDU to guarantee consistency between both objects. 1.3.6.1.4.1.1206.4.2.1.16.7 S millisecond" ::= { ascSpat 7 } ascCurrentTick2 OBJECT-TYPE SYNTAX INTEGER (0..36111) ACCESS read-only STATUS mandatory DESCRIPTION " This object is a counter of the number of elapsed ASC traffic processing ticks. The value is incremented by 1 (decisecond) every time the ASC completes its tenth of a second processing and commits a new set of IO signal states. The object is represented as a rolling counter with a zero representing the top of the hour. If the counter were to be incremented beyond 35999, unless a leap seconds occur, the value shall roll over back to 0. The values 36000..36009 are used when a leap second occurs. The values 36010..36110 are reserved for future use. 36111 is to be used when the value is undefined or unknown. See Annex F.3.3.1 for additional guidance. 1.3.6.1.4.1.1206.4.2.1.16.8 S tenth of a second" REFERENCE "SAE J2735 DE_TimeMark" DEFVAL { 36111 } ::= { ascSpat 8 } maxSignalGroups OBJECT-TYPE SYNTAX INTEGER(1..255) ACCESS read-only STATUS mandatory DESCRIPTION " This object indicates the maximum rows which shall appear in the signalGroupEntryTable object. 1.3.6.1.4.1.1206.4.2.1.16.9 S signalGroupID" ::= { ascSpat 9 } signalGroupEntryTable OBJECT-TYPE SYNTAX SEQUENCE OF SignalGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " This table contains configuration information for a signalGroupID at a signalized intersection. The number of rows in this table is equal to the maxSignalGroups object. See Annex F.3.3.5.1 for additional guidance. static 1.3.6.1.4.1.1206.4.2.1.16.10" ::= { ascSpat 10 } signalGroupEntry OBJECT-TYPE SYNTAX SignalGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Parameters for specific signal groups at an intersection. 1.3.6.1.4.1.1206.4.2.1.16.10.1" INDEX { signalGroupEntryNumber } ::= { signalGroupEntryTable 1 } SignalGroupEntry ::= SEQUENCE { signalGroupEntryNumber INTEGER, signalGroupIntersection INTEGER, signalGroupID INTEGER, signalGroupControlSource INTEGER, signalGroupControlType INTEGER, signalGroupGreenType INTEGER, signalGroupRedType INTEGER, signalGroupPermissiveControlSource INTEGER, signalGroupPermissiveControlType INTEGER, signalGroupLane INTEGER } signalGroupEntryNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The number for objects in this row. This value shall not exceed the maxSignalGroups object value. 1.3.6.1.4.1.1206.4.2.1.16.10.1.1 S" ::= { signalGroupEntry 1 } signalGroupIntersection OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION " The number is used to uniquely define an intersection within the region. A value of 0 indicates that the row is disabled and all other values in the row are not valid. 1.3.6.1.4.1.1206.4.2.1.16.10.1.2 P" REFERENCE "SAE J2735 DE_IntersectionID" DEFVAL { 0 } ::= { signalGroupEntry 2 } signalGroupID OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " The number used to map between a movement phase state (and its timings) in the CU and movements defined in a MAP message for the intersection. A value of 255 is reserved to indicate a permanent green movement state. A value of 0 indicates not available or not known. 1.3.6.1.4.1.1206.4.2.1.16.10.1.3 P" REFERENCE "SAE J2735 DE_SignalGroupID" DEFVAL { 255 } ::= { signalGroupEntry 3 } signalGroupControlSource OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " This object defines which Phase or Overlap controls the signal group. The value shall not exceed maxPhases or maxOverlaps as determined by the signalGroupControlType object: Value 00 = No Control (Not In Use) Value 01 = Phase 01 or Overlap A Value 02 = Phase 02 or Overlap B || Value 15 = Phase 15 or Overlap O Value 16 = Phase 16 or Overlap P etc. 1.3.6.1.4.1.1206.4.2.1.16.10.1.4 P" DEFVAL { 0 } ::= { signalGroupEntry 4 } signalGroupControlType OBJECT-TYPE SYNTAX INTEGER { other (1), phaseVehicle (2), phasePedestrian (3), overlap (4), pedOverlap (5), queueJump (6) } ACCESS read-write STATUS mandatory DESCRIPTION " This object defines the type of control for the signal group: other: The signal group is not controlled by a type defined by this standard. Per NTCIP 8004 v02, an attempt to write a value of 'other' shall return a badValue error. A user- or manufacturer- specific object is permitted to extend the possible states. phaseVehicle: The signal group is for a vehicle phase, bicycle phase, or transit phase. phasePedestrian: The signal group is for a pedestrian phase. overlap: The signal group is for an overlap for vehicles, bicycles, or transit. pedOverlap: The signal group is for a pedestrian overlap. queueJump: The signal group is for a queue jump, typically transit priority. 1.3.6.1.4.1.1206.4.2.1.16.10.1.5 P" ::= { signalGroupEntry 5 } signalGroupGreenType OBJECT-TYPE SYNTAX INTEGER { other (1), preMovement (2), permissiveMovementAllowed (3), protectedMovementAllowed (4), protectedPermissive (5)} ACCESS read-write STATUS mandatory DESCRIPTION " This object defines the type of Green to be indicated for the signal group in a SPaT message: other: The signal group green type is not defined by this standard. Per NTCIP 8004 v02, an attempt to write a value of 'other' shall return a badValue error. A user- or manufacturer-specific object is permitted to extend the possible states. preMovement: Prepare to proceed. Not common in the US. permissiveMovementAllowed: The signal group is a permissive green and may have to yield to conflicting traffic. protectedMovementAllowed: The signal group is a protected green and has the right-of-way. protectedPermissive: Indicates that the movement for the signal group can be protected during some portions of the cycle and permissive during other portions of the cycle. The signalGroupPermissiveControlSource and signalGroupPermissiveControlType objects determine if the movement is protected or permissive. 1.3.6.1.4.1.1206.4.2.1.16.10.1.6 P" REFERENCE "SAE J2735 DE_MovementPhaseState" ::= { signalGroupEntry 6 } signalGroupRedType OBJECT-TYPE SYNTAX INTEGER { other (1), stopThenProceed (2), stopAndRemain (3)} ACCESS read-write STATUS mandatory DESCRIPTION " This object defines the type of Red to be indicated for the signal group in a SPaT message: other: The signal group red type is not defined by this standard. Per NTCIP 8004 v02, an attempt to write a value of 'other' shall return a badValue error. A user- or manufacturer-specific object is permitted to extend the possible states. stopThenProceed: Indicates the vehicle must stop at the stop line when the signal indication is red. It may then proceed if it is safe. stopAndRemain: Indicates the traveler must stop and remain at the stop line when the signal indication is red. It may not proceed. 1.3.6.1.4.1.1206.4.2.1.16.10.1.7 P" REFERENCE "SAE J2735 DE_MovementPhaseState" ::= { signalGroupEntry 7 } signalGroupPermissiveControlSource OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " If signalGroupGreenType is protectedPermissive(5) for the row, this object in combination with signalGroupPermissiveControlType identifies which phase or overlap controls the permissive portion of the protected- permissive movement. If signalGroupGreenType is any value other than protectedPermissive(5), then this object is ignored. The value shall not exceed maxPhases or maxOverlaps as determined by the signalGroupPermissiveControlType object: Value 00 = No Control (Not In Use) Value 01 = Phase 01 or Overlap A Value 02 = Phase 02 or Overlap B || Value 15 = Phase 15 or Overlap O Value 16 = Phase 16 or Overlap P etc. 1.3.6.1.4.1.1206.4.2.1.16.10.1.8 P" DEFVAL { 0 } ::= { signalGroupEntry 8 } signalGroupPermissiveControlType OBJECT-TYPE SYNTAX INTEGER { other (1), none (2), phaseVehicle (3), phasePedestrian (4), overlap (5), pedOverlap (6), queueJump (7) } ACCESS read-write STATUS mandatory DESCRIPTION " If signalGroupGreenType is protectedPermissive(5) for the row, this object in combination with signalGroupPermissiveControlSource identifies which phase or overlap controls the permissive portion of the protected- permissive movement. If signalGroupGreenType is any value other than protectedPermissive(5), then this object is ignored. other: The signal group is not controlled by a type defined by this standard. Per NTCIP 8004 v02, an attempt to write a value of 'other' shall return a badValue error. A user- or manufacturer- specific object is permitted to extend the possible states. none: The signal group is not dependent on another phase nor overlap. phaseVehicle: The signal group is dependent on a vehicle phase, bicycle phase, or transit phase. phasePedestrian: The signal group is dependent on a pedestrian phase. Overlap: The signal group is dependent on an overlap for vehicles, bicycles, or transit. pedOverlap: The signal group is dependent on a pedestrian overlap. queueJump: The signal group is dependent on a queue jump, typically transit priority. 1.3.6.1.4.1.1206.4.2.1.16.10.1.9 P" DEFVAL { none } ::= { signalGroupEntry 9 } signalGroupLane OBJECT-TYPE SYNTAX INTEGER (0..254) ACCESS read-write STATUS mandatory DESCRIPTION " The value is equal to the enabledLaneIndex in the spatEnabledLanesConcurrencyTable. Each octet within the octet string for enabledLaneConcurrency in that row contains the (revocable) lane number that must be enabled for this signal group to be enabled. If all specified lanes are enabled, then this signal group is enabled and in use. Otherwise, the signal group is disabled and not used. A value of 0 indicates that this signal group is not dependent on a revocable lane. This value shall not exceed the maxEnabledLanesConcurrency object value. 1.3.6.1.4.1.1206.4.2.1.16.10.1.10 P" DEFVAL { 0 } ::= { signalGroupEntry 10 } maxAgencySignalStates OBJECT-TYPE SYNTAX INTEGER (3..255) ACCESS read-only STATUS mandatory DESCRIPTION " This object indicates the maximum rows which shall appear in the agencySignalStateTable object. 1.3.6.1.4.1.1206.4.2.1.16.11 S" ::= { ascSpat 11 } agencySignalStateTable OBJECT-TYPE SYNTAX SEQUENCE OF AgencySignalStateEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " This table is a lookup table to determine the movement phase state for a signal group. See Annex F.3.3.5.2 for additional guidance and see Figure 15 for the default values for the table. 1.3.6.1.4.1.1206.4.2.1.16.12" ::= { ascSpat 12 } agencySignalStateEntry OBJECT-TYPE SYNTAX AgencySignalStateEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " This table defines the signal state to provide for a signal group in the SPaT message based upon the parameters set in the signalGroupEntryTable. 1.3.6.1.4.1.1206.4.2.1.16.12.1" INDEX { agencySignalStateNumber } ::= { agencySignalStateTable 1 } AgencySignalStateEntry ::= SEQUENCE { agencySignalStateNumber INTEGER, agencySignalStateColor INTEGER, agencySignalStateControlType INTEGER, agencySignalStateOptions INTEGER, agencySignalStateValue INTEGER } agencySignalStateNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The number for objects in this row. This value shall not exceed the maxAgencySignalStates object value. 1.3.6.1.4.1.1206.4.2.1.16.12.1.1 S" ::= { agencySignalStateEntry 1 } agencySignalStateColor OBJECT-TYPE SYNTAX INTEGER { other (1), red (2), yellow (3), green (4), dark (5), flashingRed (6), flashingYellow (7) } ACCESS read-write STATUS mandatory DESCRIPTION " This object indicates the color of the phase or overlap that the signal group is associated with to determine a signal state to broadcast in a SPaT message. other: The phase or overlap is not defined by the standard. Per NTCIP 8004 v02, an attempt to write a value of 'other' shall return a badValue error. A user- or manufacturer-specific object is permitted to extend the possible states. red: The phase or overlap is red. If the agencySignalStateControlType object is pedestrian(3), this value indicates a Steady Don't Walk. yellow: The phase or overlap is yellow. green: The phase or overlap is green. If the agencySignalStateControlType object is pedestrian(3), this value indicates a Walk. dark: The phase or overlap is dark. flashingRed: The phase or overlap is Flashing Red. If the agencySignalStateControlType object is pedestrian(3), this value indicates a Flashing Don't Walk. flashingYellow: The phase or overlap is Flashing Yellow. 1.3.6.1.4.1.1206.4.2.1.16.12.1.2 P" ::= { agencySignalStateEntry 2 } agencySignalStateControlType OBJECT-TYPE SYNTAX INTEGER { other (1), vehicle (2), pedestrian (3) } ACCESS read-write STATUS mandatory DESCRIPTION " This object defines the type of control for the signal group (Vehicle Phase, Pedestrian Phase, Overlap or Pedestrian Overlap) to be used to determine the movement phase state to broadcast in a SPaT message: other: The signal group is not defined by the standard. Per NTCIP 8004 v02, an attempt to write a value of 'other' shall return a badValue error. A user- or manufacturer-specific object is permitted to extend the possible states. vehicle: The signal group is is configured in the signalGroupEntryTable with a control type of phaseVehicle (3) or overlap (5) or queueJump (7). pedestrian: The signal group is configured in the signalGroupEntryTable with a control type of phasePedestrian (4) or pedOverlap (6). 1.3.6.1.4.1.1206.4.2.1.16.12.1.3 P" ::= { agencySignalStateEntry 3 } agencySignalStateOptions OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION " Additional parameters for determining the movement phase state to broadcast in a SPaT message ( 0 = FALSE/Disabled, 1 = TRUE/Enabled ) Bit 15: Reserved Bit 14: Reserved Bit 13: Reserved Bit 12: Reserved Bit 10: Reserved Bit 11: Reserved Bit 9: The signalGroupPermissiveControlSource / signalGroupPermissiveControlType indication is Flashing Red. Bit 8: The signalGroupPermissiveControlSource / signalGroupPermissiveControlType indication is Flashing Yellow. Bit 7: The signalGroupPermissiveControlSource / signalGroupPermissiveControlType indication is Green. Bit 6: The signalGroupPermissiveControlSource / signalGroupPermissiveControlType indication is Yellow. Bit 5: The signalGroupPermissiveControlSource / signalGroupPermissiveControlType indication is Red. Bit 4: Protected Green - If Bit 1 is TRUE, the signal group is configured in the signalGroupEntryTable with a signalGroupGreenType of protectedMovementAllowed (4) or protectedPermissive (5). Bit 3: Permissive Green - If Bit 1 is TRUE, the signal group is configured in the signalGroupEntryTable with a signalGroupGreenType of permissiveMovementAllowed (3) or protectedPermissive (5). Bit 2: preMovement Green - If Bit 1 is TRUE, the signal group is configured in the signalGroupEntryTable with a signalGroupGreenType is preMovement (2). Not used in the US. Bit 1: stopAndRemain - If Bit 1 is TRUE, the signal group is configured in the signalGroupEntryTable with a signalGroupRedType of stopAndRemain (3). Bit 0: stopThenProceed - If Bit 1 is TRUE, the signal group is configured in the signalGroupEntryTable with a signalGroupRedType of stopThenProceed (2). If both Bits 0 and 1 are FALSE, then the signalGroupRedType is not applicable. Bits 0 and 1 cannot be both TRUE. A SET of both bits 0 and 1 to TRUE shall result return a badValue(3) error. If both Bits 3 and 4 are FALSE, then the signalGroupGreenType is not applicable. If only Bit 3 is TRUE, then the signalGroupGreenType for the the signal group in the signalGroupEntryTable is permissiveMovementAllowed (3). If only Bit 4 is TRUE, then the signalGroupGreenType for the signal group in the signalGroupEntryTable is protectedMovementAllowed (4). If both Bits 3 and 4 are TRUE, that indicates the signalGroupGreenType is protectedPermissive and the signal indication of signalGroupPermissiveControlType and signalGroupPermissiveControlSource determines if the signal green type is permissiveMovementAllowed or protectedMovementAllowed. Bits 5-9 determine what signal indication(s) of the signalGroupPermissiveControlType / signalGroupPermissiveControlSource makes the movement permissive. If Bits 5-9 are all TRUE, then ANY signal indication of the signalGroupPermissiveControlType / signalGroupPermissiveControlSource determines if the movement is permissive. If Bits 5-9 are all FALSE, then the color of the signalGroupPermissiveControlType / signalGroupPermissiveControlSource is not applicable. See Annex F.3.3.5.2 and F.3.3.5.3 for additional guidance. 1.3.6.1.4.1.1206.4.2.1.16.12.1.4 P" ::= { agencySignalStateEntry 4 } agencySignalStateValue OBJECT-TYPE SYNTAX INTEGER { other (1), unavailable (2), dark (3), stopThenProceed (4), stopAndRemain (5), preMovement (6), permissiveMovementAllowed (7), protectedMovementAllowed (8), permissiveClearance (9), protectedClearance (10), cautionConflictingTraffic (11) } ACCESS read-write STATUS mandatory DESCRIPTION " This object indicates the movement phase state to be broadcasted in a SPaT message. other: The movement phase state is not defined by the standard. unavailable: The state of the movement is unknown or an error occurred. dark: The signal head is dark (unlit) stopThenProceed: Indicates the vehicle must stop at the stop line. It may proceed if it is safe. stopAndRemain: Indicates the vehicle must stop at the stop line. It may not proceed. preMovement: Prepare to proceed. permissiveMovementAllowed: Indicates a permissive green. protectedMovementAllowed: Indicates a protected green (a steady green arrow). permissiveClearance: Prepare to stop. Vehicle may proceed if unable to stop. Conflicting traffic may be present. protectedClearance: Prepare to stop. Vehicle may proceed if unable to stop. cautionConflictingTraffic: Proceed with caution. Conflicting traffic may be present. 1.3.6.1.4.1.1206.4.2.1.16.12.1.5 P" REFERENCE "SAE J2735 DE_MovementPhaseState" DEFVAL { unavailable } ::= { agencySignalStateEntry 5 } maxEnabledLanesConcurrency OBJECT-TYPE SYNTAX INTEGER (1..254) ACCESS read-only STATUS mandatory DESCRIPTION " This object indicates the maximum rows which shall appear in the spatEnabledLanesConcurrencyTable object. 1.3.6.1.4.1.1206.4.2.1.16.13 S" ::= { ascSpat 13 } spatEnabledLanesCommand2 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " This object establishes the Enabled lanes for the device to be broadcast in a SPaT message. The value is equal to the enabledLaneIndex in the spatEnabledLanesConcurrencyTable. Each octet within the octet string for enabledLaneConcurrency in that row contains the (revocable) lane number(s) that are enabled. The new set of Enabled lanes will be broadcast at the top of the next cycle. A value of 0 indicates that there are no enabled lanes. A value of 255 indicates that the device shall cancel this command and shall revert back to the Enabled lanes defined in the timebaseAscActionTable timebaseAscActionLane. Otherwise, the Enabled lanes defined is this command shall override the Enabled lanes defined in timebaseAscActionLane. If an unsupported / invalid set of Enabled lanes is called, then the spatPortStatus object shall be SET to enabledLanesError(5) for all valid entries in the spatPortTable. 1.3.6.1.4.1.1206.4.2.1.16.14 P" REFERENCE "SAE J2735 DF_EnabledLaneList" ::= { ascSpat 14 } rsuAsc OBJECT IDENTIFIER ::= { asc 17 } -- This defines a node for objects to support a CV Roadside Process in a connected vehicle environment. MapActivationCode ::= OCTET STRING (SIZE(3)) -- The MapActivationCode consists of those parameters required to activate a -- MAP Plan message in an ASC. It is defined as an OCTET STRING containing -- the OER-encoding of the following ASN.1 structure. -- mapActivationCodeStructure ::= SEQUENCE { -- mapPlanIndex INTEGER (1..8), -- mapPlanCRC OCTET STRING (SIZE (2)) } -- -- mapPlanIndex (8 bits) shall indicate the mapPlanIndex requested. -- -- mapPlanCRC (16 bits) shall indicate the mapPlanCRC of the requested -- mapPlanIndex. rsuAscSpat OBJECT IDENTIFIER ::= { rsuAsc 1 } -- This defines a node for objects to support signalized intersection -- applications in a CV Roadside Process in a connected vehicle environment. maxRsuAscs OBJECT-TYPE SYNTAX INTEGER (1..32) ACCESS read-only STATUS deprecated DESCRIPTION " This object contains the maximum number of signal controller entries this RSU supports. Each entry represents a signalized intersection whose signal phase and timing information is broadcast by the RSU. This object indicates the maximum rows which shall appear in the mapIntersectionTable object. 1.3.6.1.4.1.1206.4.2.1.17.1.1 S movement" ::= { rsuAscSpat 1 } rsuAscSpatTable OBJECT-TYPE SYNTAX SEQUENCE OF RsuAscSpatEntry ACCESS not-accessible STATUS deprecated DESCRIPTION " This table contains information describing the signal phase and timing information for a signalized intersection broadcast by the RSU. The number of rows in this table is equal to the maxRsuAscs object. static 1.3.6.1.4.1.1206.4.2.1.17.1.2" ::= { rsuAscSpat 2 } rsuAscSpatEntry OBJECT-TYPE SYNTAX RsuAscSpatEntry ACCESS not-accessible STATUS deprecated DESCRIPTION " Signal phase and timing information for a signalized intersection broadcast in a SPaT message. 1.3.6.1.4.1.1206.4.2.1.17.1.2.1" INDEX { rsuAscSpatIndex } ::= { rsuAscSpatTable 1 } RsuAscSpatEntry::= SEQUENCE { rsuAscSpatIndex INTEGER, rsuAscSpatId INTEGER, rsuAscSpatMsgCount INTEGER, rsuAscSpatMinuteOfTheYear INTEGER, rsuAscSpatMilliseconds INTEGER, rsuAscSpatEnabledLanes OCTET STRING } rsuAscSpatIndex OBJECT-TYPE SYNTAX INTEGER (1..32) ACCESS read-only STATUS deprecated DESCRIPTION " The index number of the signalized intersection objects in this row. This value shall not exceed the maxRsuAscs object value. 1.3.6.1.4.1.1206.4.2.1.17.1.2.1.1 node" ::= { rsuAscSpatEntry 1 } rsuAscSpatId OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS deprecated DESCRIPTION " To support SAE J2735, the regionally unique identifier of the intersection. 1.3.6.1.4.1.1206.4.2.1.17.1.2.1.2" REFERENCE "SAE J2735 DE_IntersectionID" ::= { rsuAscSpatEntry 2 } rsuAscSpatMsgCount OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-only STATUS deprecated DESCRIPTION " To support SAE J2735, a sequence number that is incremented when the contents for the intersection in the SPaT data message has changed. 1.3.6.1.4.1.1206.4.2.1.17.1.2.1.3" REFERENCE "SAE J2735 DF_IntersectionState and DE_MsgCount" ::= { rsuAscSpatEntry 3 } rsuAscSpatMinuteOfTheYear OBJECT-TYPE SYNTAX INTEGER (0..527040) ACCESS read-only STATUS deprecated DESCRIPTION " To support SAE J2735, the minute of the current year SPaT data for this intersection in this row was last broadcast by the CV Roadside Process. 1.3.6.1.4.1.1206.4.2.1.17.1.2.1.4" REFERENCE "SAE J2735 DF_IntersectionState and DE_MinuteOfTheYear" DEFVAL { 0 } ::= { rsuAscSpatEntry 4 } rsuAscSpatMilliseconds OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS deprecated DESCRIPTION " To support SAE J2735, the millisecond of the current minute (rsuAscSpatMinuteOfTheYear) SPaT data for this intersection in this row was generated. 1.3.6.1.4.1.1206.4.2.1.17.1.2.1.5" REFERENCE "SAE J2735 DF_IntersectionState and DE_DSecond" DEFVAL { 0 } ::= { rsuAscSpatEntry 5 } rsuAscSpatEnabledLanes OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS deprecated DESCRIPTION " To support SAE J2735, this object is used to indicate the Enabled lanes list generated by a specific signal controller and broadcast in a SPaT message. Each octet within the octet string contains the mapLaneIndex(s) (binary value) in the MAP plan data configuration that is broadcast to be ACTIVE. Lanes that may not always be ACTIVE (enabled) are identified as a RevocableLane (Bit 0) in mapLaneType. If a lane is to be identified as ACTIVE, the mapLaneIndex is added to this OCTET STRING. 1.3.6.1.4.1.1206.4.2.1.17.1.2.1.6" REFERENCE "SAE J2735 DF_EnabledLaneList" DEFVAL { "" } ::= { rsuAscSpatEntry 6 } rsuSpatMinuteOfTheYear OBJECT-TYPE SYNTAX INTEGER (0..527040) ACCESS read-only STATUS deprecated DESCRIPTION " To support SAE J2735, the minute of the current year a SPaT message was last broadcast by the CV Roadside Process. 1.3.6.1.4.1.1206.4.2.1.17.1.3" REFERENCE "SAE J2735 MSG_SignalPhaseAndTiming Message and DE_MinuteOfTheYear" DEFVAL { 0 } ::= { rsuAscSpat 3 } mapActivatePlan OBJECT-TYPE SYNTAX MapActivationCode ACCESS read-write STATUS mandatory DESCRIPTION " A code indicating the active MAP plan. The value of this object may be SET by a management station. If a GET is performed on this object, the device shall respond with the value for the last MAP plan that was successfully activated. The mapActivatePlanError object shall be updated appropriately upon any attempt to update the value of this object. If a MAP plan activation error occurs (e.g., mapActivatePlanError is updated to a value other than 'none'), the new MAP plan shall not be activated and a genErr shall be returned. A management station should then GET the mapActivatePlanError object as soon as possible to minimize the chance of additional activation attempts from overwriting the mapActivatePlanError. A value of 00 00 00 indicates no MAP plan is active and thus no MAP data should be broadcast. 1.3.6.1.4.1.1206.4.2.1.17.1.4" ::= { rsuAscSpat 4 } mapActivatePlanError OBJECT-TYPE SYNTAX INTEGER { other (1), none (2), mapPlanIndex (3), mapPlanCRC (4) } ACCESS read-only STATUS mandatory DESCRIPTION " This is an error code used to identify why a commanded MAP plan was not not implemented. other: any error not defined by this standard. none: no error. mapPlanIndex: the MAP plan index requested is not supported or is not defined (populated) by the device. mapPlanCRC: the checksum in the mapActivatePlan is different than the CRC value contained in the 'mapPlanCRC'. 1.3.6.1.4.1.1206.4.2.1.17.1.5" ::= { rsuAscSpat 5 } ascCvDetector OBJECT IDENTIFIER ::= { rsuAsc 2 } -- This defines a node for a CV Roadside Process to support detection of connected devices in a connected vehicle environment. cvDetectionEnable OBJECT-TYPE SYNTAX INTEGER { enabled (1), disabled (2) } ACCESS read-write STATUS deprecated DESCRIPTION " This object is used to enable/disable detection zones in a connected vehicle environment. If enabled, the CU allows detectors defined in vehicleDetectorTable and pedestrianDetectorTable to use inputs from the connected vehicle environment. Inputs may be in the form of actuations, safety messages and/or detection reports in the detectionReportTable. 1.3.6.1.4.1.1206.4.2.1.17.2.1" DEFVAL { disabled } ::= { ascCvDetector 1 } maxCvDetectionZones OBJECT-TYPE SYNTAX INTEGER(1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The maximum number of connected vehicle detection zones this RSU supports. This object indicates the maximum rows which appear in the ascCvDetectorTable object. 1.3.6.1.4.1.1206.4.2.1.17.2.2" ::= { ascCvDetector 2 } ascCvDetectorTable OBJECT-TYPE SYNTAX SEQUENCE OF AscCvDetectorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table containing the connected vehicle detection zone parameters for this RSU. The number of rows in this table is equal to the maxCvDetectionZones object. static 1.3.6.1.4.1.1206.4.2.1.17.2.3" ::= { ascCvDetector 3 } ascCvDetectorEntry OBJECT-TYPE SYNTAX AscCvDetectorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Parameters for a specific connected vehicle detection zone. 1.3.6.1.4.1.1206.4.2.1.17.2.3.1" INDEX { ascCvDetectorNumber } ::= { ascCvDetectorTable 1 } AscCvDetectorEntry ::= SEQUENCE { ascCvDetectorNumber INTEGER, ascCvDetectorOptions INTEGER, --deprecated ascCvDetectorIntersection INTEGER, --deprecated ascCvDetectorInput OCTET STRING, --deprecated ascCvDetectorAssignment OCTET STRING, --deprecated ascCvDetectorSamplePeriod INTEGER, --deprecated ascCvDetectorUserClass INTEGER, --deprecated ascCvDetectorHeading INTEGER, --deprecated ascCvDetectorMinSpeed INTEGER, --deprecated ascCvDetectorMaxSpeed INTEGER, --deprecated ascCvDetectorMinSize INTEGER, --deprecated ascCvDetectorMaxSize INTEGER, --deprecated ascCvDetectorFlags INTEGER }--deprecated ascCvDetectorNumber OBJECT-TYPE SYNTAX INTEGER(1..255) ACCESS read-only STATUS mandatory DESCRIPTION " The connected vehicle detection zone number for objects in this row. This value shall not exceed the maxCvDetectionZones object value. 1.3.6.1.4.1.1206.4.2.1.17.2.3.1.1" ::= { ascCvDetectorEntry 1 } ascCvDetectorOptions OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS deprecated DESCRIPTION " Connected Detection Zone Options Parameter as follows (0=Disabled, 1=Enabled): Bit 7: Reserved Bit 6: Enable processed data - enables the exchange of detectionReports across the ASC - RSU interface. Bit 5: Enable actuation. - enables the ascCvDetectionActuations object for this detection zone. Bits 3 & 4: Indicates which detector table the detector number in ascCvDetectorAssignment is assigned to. Bit 3 = 0, Bit 4 = 0 - unknown or not applicable Bit 3 = 1, Bit 4 = 0 - vehicleDetectorTable Bit 3 = 0, Bit 4 = 1 - pedestrianDetectorTable Bit 4 = 1, Bit 4 = 1 - Reserved Bit 2: Input Type - A value of 0 indicates the detection zone boundaries are defined by mapLaneIndex (that is, the detection zone boundaries are equal to the boundaries of the lane indexed). A value of 1 indicates the detection zone boundaries are defined by detectionZoneNodePointIndex. Bit 1: A bit value of 1 enables the processing of Personal Safety messages (PSMs) detected within the detection zone. Bit 0: A bit value of 1 enables the processing of Basic Safety Messages (BSMs) detected within the detection zone. 1.3.6.1.4.1.1206.4.2.1.17.2.3.1.2" ::= { ascCvDetectorEntry 2 } ascCvDetectorIntersection OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS deprecated DESCRIPTION " An object referencing the intersection that this connected vehicle detection zone is associated with. This reference is used to establish which controller unit the actuations are intended for and the reference point for the geometric boundaries of the detection zone (ascCvDetectorInput). 0 indicates no intersection has been associated with this CV detection zone. 1.3.6.1.4.1.1206.4.2.1.17.2.3.1.3" DEFVAL { 0 } ::= { ascCvDetectorEntry 3 } ascCvDetectorInput OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS deprecated DESCRIPTION " A null octet string indicates there is no geographic boundary, so any safety message received that satisfies the other criteria defined in the row is valid, regardless of its geographic location. If Bit 2 of ascCvDetectorOptions is equal to 0, then each octet within the octet string represents a mapLaneIndex that defines the geographic boundaries of the detection zone for this connected device detector. If Bit 2 of ascCvDetectorOptions is equal to 1, then the octet represents the detectionZoneNodePointIndex that defines the geometric boundaries for this connected vehicle detector. The maximum size of this octet string is equal to the greater of maxLanes or maxDetectionZoneNodePoints. 1.3.6.1.4.1.1206.4.2.1.17.2.3.1.4" DEFVAL { "" } ::= { ascCvDetectorEntry 4 } ascCvDetectorAssignment OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS deprecated DESCRIPTION " Each octet in this octet string represents a detector number in the appropriate detector table (as defined in Bits 3 and 4 in ascCvDetectorOptions) of the reference intersection (ascCvDetectorIntersection) that this connected vehicle detector is assigned to. Any Basic Safety Messages or Personal Safety Messages that satisfy all the criteria defined in the row will result in an actuation for this detector or can be used as an input for this detector. A null value indicates this detection zone is not assigned to any detector number. 1.3.6.1.4.1.1206.4.2.1.17.2.3.1.5" DEFVAL { "" } ::= { ascCvDetectorEntry 5 } ascCvDetectorSamplePeriod OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS deprecated DESCRIPTION " This object defines the frequency (in seconds) that a detection report for this connected vehicle detection zone is generated and exchanged. This object is enabled if the collection of processed data is enabled (ascCvDetectionOptions, Bit 7 = 1). 1.3.6.1.4.1.1206.4.2.1.17.2.3.1.6 seconds" DEFVAL { 0 } ::= { ascCvDetectorEntry 6 } ascCvDetectorUserClass OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS deprecated DESCRIPTION " The mapUserClassId value to which this connected vehicle detection zone applies to. Only connected devices that satisfy all of the vehicle types defined may result in an actuation for this detector. A value of 0 indicates that any vehicle type may result in an actuation. 1.3.6.1.4.1.1206.4.2.1.17.2.3.1.7" ::= { ascCvDetectorEntry 7 } ascCvDetectorHeading OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS deprecated DESCRIPTION " To support SAE J2735, this object represents heading slices that this connected vehicle detection zone applies to. Only connected devices that have a current heading within one of the enabled heading slices may result in an actuation for this detector. A value of 1 indicates that the heading slice is enabled. 1.3.6.1.4.1.1206.4.2.1.17.2.3.1.8" REFERENCE "SAE J2735 DE_HeadingSlice" DEFVAL { 0 } ::= { ascCvDetectorEntry 8 } ascCvDetectorMinSpeed OBJECT-TYPE SYNTAX INTEGER (0..8191) ACCESS read-write STATUS deprecated DESCRIPTION " This object represents the minimum speed, in 0.02 meters per second units, that this connected vehicle detection zone applies to. A value of 0 indicates that the connected vehicle detection zone applies to connected devices of any speed. A value of 8190 indicates the detector zone applies only to speeds equal to or greater than 40.90 meters per second. 1.3.6.1.4.1.1206.4.2.1.17.2.3.1.9" DEFVAL { 0 } ::= { ascCvDetectorEntry 9 } ascCvDetectorMaxSpeed OBJECT-TYPE SYNTAX INTEGER (0..8191) ACCESS read-write STATUS deprecated DESCRIPTION " This object represents the maximum speed, in 0.02 meters per second units, that this connected vehicle detection zone applies to. A value of 0 is reserved. A value of 8190 indicates that the connected vehicle detection zone applies to connected devices that are equal to or less than 40.90 meters per second. A value of 8191 indicates that this object is not used and that the connected vehicle detection zone applies to connected devices of any speed. 1.3.6.1.4.1.1206.4.2.1.17.2.3.1.10 0.02 meters per second" DEFVAL { 8191 } ::= { ascCvDetectorEntry 10 } ascCvDetectorMinSize OBJECT-TYPE SYNTAX INTEGER (0..4194303) ACCESS read-write STATUS deprecated DESCRIPTION " This object represents the minimum vehicle size, in centimeters, that this connected vehicle detection zone applies to. Bits 0 to 9 represents the minimum width of the vehicle, and Bits 10 to 21 represents the minimum length of the vehicle. A value of 0 indicates that the connected vehicle detection zone applies to connected devices of any size. This object is valid only for BSMs. 1.3.6.1.4.1.1206.4.2.1.17.2.3.1.11" DEFVAL { 0 } ::= { ascCvDetectorEntry 11 } ascCvDetectorMaxSize OBJECT-TYPE SYNTAX INTEGER (0..4194303) ACCESS read-write STATUS deprecated DESCRIPTION " This object represents the maximum vehicle size, in centimeters, that this connected vehicle detection zone applies to. Bits 0 to 9 represents the maximum width of the vehicle, and Bits 10 to 21 represents the maximum length of the vehicle. A value of 0 is reserved. A value of 4194303 indicates that this object is not used and that the connected vehicle detection zone applies to connected devices of any s.ize. 1.3.6.1.4.1.1206.4.2.1.17.2.3.1.12 0.02 meters per second" DEFVAL { 4194303 } ::= { ascCvDetectorEntry 12 } ascCvDetectorFlags OBJECT-TYPE SYNTAX INTEGER(0..255) ACCESS read-write STATUS deprecated DESCRIPTION " To support SAE J2735, this object represents a filter for the event flags and brake status of a connected vehicle that this connected vehicle detection zone applies to. If a value is set to true (set to 1), this indicates that only basic safety messages whose event flag status is also true will result in an actuation, will be exchanged, or will be stored (as appropriate) for that connected device detection zone. If multiple values are set to true, then any basic safety messages that satisfy ANY ONE of those values will result in an actuation, exchanged, or stored (i.e., this is an OR object). Bit 15: braking active Bit 14: brake boost assist engaged Bit 13: auxiliary brake engaged Bit 12: Air bags deployed Bit 11: Vehicle disabled Bit 10: Flat tire Bit 9: Status of wiper (front or back) changed within last the 2 seconds Bit 8: Status of the exterior lights changed within the last 2 seconds Bit 7: Hard braking (greater than 0.4 g) Bit 6: Reserved Bit 5: Carrying hazardous materials and placarded as such Bit 4: Stability control active and exceeding 100 mSec Bit 3: Traction control active and exceeding 100 mSec Bit 2: Anti Lock Brakes active and exceeding 100 mSec Bit 1: Stop line violation Bit 0: Hazard lights are active 1.3.6.1.4.1.1206.4.2.1.17.2.3.1.13" REFERENCE "SAE J2735 DF_BrakeSystemStatus DE_VehicleEventFlags" DEFVAL { 0 } ::= { ascCvDetectorEntry 13 } maxDetectionZoneNodePoints OBJECT-TYPE SYNTAX INTEGER(2..255) ACCESS read-only STATUS deprecated DESCRIPTION " The maximum number of connected vehicle detection zone node points this CU supports. This object indicates the maximum rows which appear in the detectionZoneNodePointTable object. 1.3.6.1.4.1.1206.4.2.1.17.2.4" DEFVAL { 63 } ::= { ascCvDetector 4 } detectionZoneNodePointTable OBJECT-TYPE SYNTAX SEQUENCE OF DetectionZoneNodePointEntry ACCESS not-accessible STATUS deprecated DESCRIPTION " A table containing the node points for a connected vehicle detection zone parameters in this RSU. The number of rows in this table is equal to the maxDetectionZoneNodePoints object. static 1.3.6.1.4.1.1206.4.2.1.17.2.5" ::= { ascCvDetector 5 } detectionZoneNodePointEntry OBJECT-TYPE SYNTAX DetectionZoneNodePointEntry ACCESS not-accessible STATUS deprecated DESCRIPTION " Location of node points for a specific connected vehicle detection zone. 1.3.6.1.4.1.1206.4.2.1.17.2.5.1" INDEX { detectionZoneNodePointIndex } ::= { detectionZoneNodePointTable 1 } DetectionZoneNodePointEntry ::= SEQUENCE { detectionZoneNodePointIndex INTEGER,--deprecated detectionZoneNodePointX INTEGER,--deprecated detectionZoneNodePointY INTEGER,--deprecated detectionZoneNodePointWidth INTEGER,--deprecated detectionZoneNodePointZ INTEGER,--deprecated detectionZoneNodePointHeight INTEGER }--deprecated detectionZoneNodePointIndex OBJECT-TYPE SYNTAX INTEGER(1..255) ACCESS read-only STATUS deprecated DESCRIPTION " An index for the detection zone node points for objects in this row. This value shall not exceed the maxDetectionZoneNodePoints object value. 1.3.6.1.4.1.1206.4.2.1.17.2.5.1.1" ::= { detectionZoneNodePointEntry 1 } detectionZoneNodePointX OBJECT-TYPE SYNTAX INTEGER (-32767..32767) ACCESS read-write STATUS deprecated DESCRIPTION " Represents the X offset, in centimeters, from the previous node point (defined in the previous row of this table, with the first path node defined in the row detectionZoneNodePointIndex = 1). For row detectionZoneNodePointIndex = 1, the offset is from the reference point of the referenced intersection (ascCvDetectorIntersection). The sequence of nodes defines the centerline of the detection zone. A positive value is to the East. 1.3.6.1.4.1.1206.4.2.1.17.2.5.1.2 centimeter" ::= { detectionZoneNodePointEntry 2 } detectionZoneNodePointY OBJECT-TYPE SYNTAX INTEGER (-32767..32767) ACCESS read-write STATUS deprecated DESCRIPTION " Represents the Y offset, in centimeters, from the previous node point (defined in the previous row of this table, with the first node point defined in the row detectionZoneNodePointIndex = 1). For detectionZoneNodePointIndex = 1, the offset is from the reference point of the referenced intersection (ascCvDetectorIntersection). The sequence of node points defines the centerline of the zone. A positive value is to the North. 1.3.6.1.4.1.1206.4.2.1.17.2.5.1.3 centimeter" ::= { detectionZoneNodePointEntry 3 } detectionZoneNodePointWidth OBJECT-TYPE SYNTAX INTEGER (-32767..32767) ACCESS read-write STATUS deprecated DESCRIPTION " A value added to the current zone width at this node and from this node onwards, in 1 centimeter steps. Lane widths between nodes are a linear taper between points. 1.3.6.1.4.1.1206.4.2.1.17.2.5.1.4 centimeter" ::= { detectionZoneNodePointEntry 4 } detectionZoneNodePointZ OBJECT-TYPE SYNTAX INTEGER (-32767..32767) ACCESS read-write STATUS deprecated DESCRIPTION " Represents the Z offset, in centimeters, from the previous node point (defined in the previous row of this table, with the first node point defined in the row detectionZoneNodePointIndex = 1). For detectionZoneNodePointIndex = 1, the offset is from the reference point of the referenced intersection (ascCvDetectorIntersection). The sequence of node points defines the elevation of the roadway pavement that the zone is on top of. A positive value represents a higher elevation. 1.3.6.1.4.1.1206.4.2.1.17.2.5.1.5 centimeter" ::= { detectionZoneNodePointEntry 5 } detectionZoneNodePointHeight OBJECT-TYPE SYNTAX INTEGER (0..32767) ACCESS read-write STATUS deprecated DESCRIPTION " The height, in centimeters, above the roadway pavement for the detection zone. This value is added to the detectionZoneNodePointZ to represent the upper boundary of the detection zone. The detection zone height between node points are a linear taper between points. 1.3.6.1.4.1.1206.4.2.1.17.2.5.1.6 centimeter" ::= { detectionZoneNodePointEntry 6 } cvDetectionActuationSamplePeriod OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS deprecated DESCRIPTION "The sample period for updating the cvDetectionActuations object, in units of milliseconds. If the value is zero (0), then the cvDetectionActuations is not collected on a periodic basis. 1.3.6.1.4.1.1206.4.2.1.17.2.6 millisecond" DEFVAL { 0 } ::= { ascCvDetector 6 } maxCvDetectionGroups OBJECT-TYPE SYNTAX INTEGER (1..32) ACCESS read-only STATUS mandatory DESCRIPTION " The maximum number of connected vehicle detection zone groups (8 connected detection zones per group) this RSU supports. This value is equal to TRUNCATE [(maxCvDetectionZones + 7) / 8]. This object indicates the maximum rows which shall appear in the cvDetectionGroupTable. 1.3.6.1.4.1.1206.4.2.1.17.2.7 S centimeter" ::= { ascCvDetector 7 } cvDetectionGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF CvDetectionGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table containing status information in groups of eight connected vehicle detection zones (ascCvDetectorNumber). The number of rows in this table is equal to the maxCvDetectionGroups object. 1.3.6.1.4.1.1206.4.2.1.17.2.8" ::= { ascCvDetector 8 } cvDetectionGroupEntry OBJECT-TYPE SYNTAX CvDetectionGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " The status for eight connected vehicle device detectors. 1.3.6.1.4.1.1206.4.2.1.17.2.8.1" INDEX { cvDetectionGroupNumber } ::= { cvDetectionGroupTable 1 } CvDetectionGroupEntry ::= SEQUENCE { cvDetectionGroupNumber INTEGER, cvDetectionGroupActuations INTEGER } cvDetectionGroupNumber OBJECT-TYPE SYNTAX INTEGER (1..32) ACCESS read-only STATUS mandatory DESCRIPTION " The CV Detection Group number for objects in this row. This value shall not exceed the maxCvDetectionGroups object value. 1.3.6.1.4.1.1206.4.2.1.17.2.8.1.1 S group" ::= { cvDetectionGroupEntry 1 } cvDetectionGroupActuations OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " CV Detection Actuation Mask, where when a bit = 1, the CV Detection is currently actuated. When a bit = 0, the CV Detection is NOT currently actuated. Bit 7: CV Detection # = (cvDetectionGroupNumber * 8) Bit 6: CV Detection # = (cvDetectionGroupNumber * 8) - 1 Bit 5: CV Detection # = (cvDetectionGroupNumber * 8) - 2 Bit 4: CV Detection # = (cvDetectionGroupNumber * 8) - 3 Bit 3: CV Detection # = (cvDetectionGroupNumber * 8) - 4 Bit 2: CV Detection # = (cvDetectionGroupNumber * 8) - 5 Bit 1: CV Detection # = (cvDetectionGroupNumber * 8) - 6 Bit 0: CV Detection # = (cvDetectionGroupNumber * 8) - 7 1.3.6.1.4.1.1206.4.2.1.17.2.8.1.2 S group" ::= { cvDetectionGroupEntry 2 } detectionReportCollection OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS deprecated DESCRIPTION " This object determines what pieces of data will be exchanged and stored for the detectionReportTable. A value set to 1 indicates that piece of data shall be stored. Bit 6 & 7 = Reserved Bit 5 = platoon - detectionReportPlatoon Bit 4 = gap - detectionReportGap Bit 3 = queue length - detectionReportQueue Bit 2 = travel time - detectionReportTravelTime Bit 1 = average speed - detectionReportSpeed Bit 0 = volume - detectionReportVolume 1.3.6.1.4.1.1206.4.2.1.17.2.9" ::= { ascCvDetector 9 } activeCvDetectors OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION " The number of active CV detectors in this device. This object indicates how many rows are in the detectionReportTable object. There shall be a row for every active CV detector collecting CV data. 1.3.6.1.4.1.1206.4.2.1.17.2.10 S" ::= { ascCvDetector 10 } detectionReportSequence OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION " This object defines a sequence number for detection reports received from defined connected vehicle detection zones. This object is used to track where a new detection report received by the CU should be stored. The value cycles within the limits of 0 to 65535 and is incremented by one when a detection report is stored in the detectionReportTable. 1.3.6.1.4.1.1206.4.2.1.17.2.11 S sequence" ::= { ascCvDetector 11 } detectionReportTable OBJECT-TYPE SYNTAX SEQUENCE OF DetectionReportEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table containing detector reports for a connected vehicle detection zone defined for this CU. The number of rows in this table is equal to the activeCvDetectors object. Note: The objects in this table are read-write to allow the RSU to be the SNMP manager and the ASC to be the SNMP agent across the RSU - ASC interface. static 1.3.6.1.4.1.1206.4.2.1.17.2.12" ::= { ascCvDetector 12 } detectionReportEntry OBJECT-TYPE SYNTAX DetectionReportEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Detection reports received for a specific connected vehicle detection zone. 1.3.6.1.4.1.1206.4.2.1.17.2.12.1" INDEX { ascCvDetectorNumber } ::= { detectionReportTable 1 } DetectionReportEntry ::= SEQUENCE { detectionReportTime INTEGER, detectionReportVolume INTEGER, detectionReportSpeed INTEGER, detectionReportTravelTime INTEGER, detectionReportQueue INTEGER, detectionReportGap INTEGER, detectionReportPlatoon INTEGER } detectionReportTime OBJECT-TYPE SYNTAX INTEGER (0..3601000) ACCESS read-write STATUS mandatory DESCRIPTION " This object indicates the seconds within the hour the detector report is generated. 0 to 3600999 are in milliseconds, with a leap second represented by 3600000 to 3600999. A value of 3601000 shall represent unavailable. 1.3.6.1.4.1.1206.4.2.1.17.2.12.1.1 P millisecond" DEFVAL { 3601000 } ::= { detectionReportEntry 1 } detectionReportVolume OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " A count of the number of connected devices currently detected in the connected vehicle detection zone at the time the report was generated. This value shall range from 0 to 254. The value 255 shall indicate volume overflow. 1.3.6.1.4.1.1206.4.2.1.17.2.12.1.2 P volume" DEFVAL { 0 } ::= { detectionReportEntry 2 } detectionReportSpeed OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " The average speed, in 0.5 kilometers per hour, of the connected devices currently detected in the connected vehicle detection zone at the time the report was generated. A value of 0 to 253 is the average connected device speed in 0.5 kilometers per hour units. A value of 254 represents an average speed of 127 kilometers per hour or higher. A value of 255 represents an invalid or missing value. 1.3.6.1.4.1.1206.4.2.1.17.2.12.1.3 P 0.5 kilometers/hour" DEFVAL { 255 } ::= { detectionReportEntry 3 } detectionReportTravelTime OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION " The average travel time, in tenths of a second, for a connected device to traverse the connected vehicle detection zone at the time the report was generated. A value of 65535 represents an invalid or missing value. 1.3.6.1.4.1.1206.4.2.1.17.2.12.1.4 P tenth second" DEFVAL { 65535 } ::= { detectionReportEntry 4 } detectionReportQueue OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " A count of the number of connected vehicles currently queued in the connected vehicle detection zone at the time the report was generated. A value of 0 to 253 represents the number of vehicles queued. A value of 254 indicates the queue is 254 or more vehicles. A value of 255 represents an invalid or missing value. 1.3.6.1.4.1.1206.4.2.1.17.2.12.1.5 P" DEFVAL { 255 } ::= { detectionReportEntry 5 } detectionReportGap OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION " The average gap, in centimeters, between the connected vehicles currently detected in the connected vehicle detection zone at the time the report was generated. The gap is defined as the distance between the edge of the rear bumper of a connected vehicle and the edge of the front bumper of a connected vehicle behind it. A value of 65535 indicates an invalid or missing value. 1.3.6.1.4.1.1206.4.2.1.17.2.12.1.6 P centimeter" DEFVAL { 65535 } ::= { detectionReportEntry 6 } detectionReportPlatoon OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION " A count of the number of connected vehicles in a platoon currently detected in the connected vehicle detection zone at the time the report was generated. A value of 0 to 253 represents the number of vehicles in the platoon. A value of 254 indicates the platoon is 254 or more vehicles. A value of 255 represents an invalid or missing value. 1.3.6.1.4.1.1206.4.2.1.17.2.12.1.7 P vehicle" DEFVAL { 255 } ::= { detectionReportEntry 7 } END